Economic evaluation of a Single use Flexible Digital Ureteroscope : Cost Analysis

preprint OA: closed
Full text JSON View at publisher

Abstract

Abstract Background: The goal of our study is to analyze the possible economic benefits of single-use flexible ureteroscopes (su-fURSs) and compare their cost effectiveness with that of reusable flexible ureteroscopes (re-fURSs) in secondary hospitals with an average patient flow rate. Methodes: The present study is a single-center, retrospective study conducted at Security Force Hospital, Makkah, Saudia Arabia. The study included data from all flexible ureteroscopy procedures performed in the urology department of the hospitals between June 2021 and December 2023. Karl Storz FLEX-X2S fiber-optic ureteroscopes were used for the procedures involving re-fURS, and the cost assessment took into account the initial cost of purchasing, the cost of reprocessing, and the cost of replacement split by the number of cases. This cost was compared with the costs of using WiScope (OTU Medical Inc.), a digital su-fURS. Results: Out of the total cases included in the study, 180 utilized su-fURSs, and 59 utilized re- fURSs with one repair exchange done during the observed study period. The average cost of using a re-fURS was approximately SAR 3,668 (USD 975) per case, while the cost of using a su- fURS was approximately SAR 1,650 (USD 438) per case. Conclusions: Su-fURS is a more cost-effective procedure than re-fURS performed in secondary hospitals with an average patient flow. Su-fURS may be more reliable than re-fURS regarding wear and tear. It is essential to consider different factors such as the cost of sterilization and the time spent in cleaning when determining which scope is most cost-effective for a particular procedure.
Full text 77,330 characters · extracted from preprint-html · click to expand
Economic evaluation of a Single use Flexible Digital Ureteroscope : Cost Analysis | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Research Article Economic evaluation of a Single use Flexible Digital Ureteroscope : Cost Analysis Ahmed Ali, Abdelsalam Abdelfadel, Suhail Kalantan, Amer Azzam, and 6 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-5069441/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 18 Jun, 2025 Read the published version in African Journal of Urology → Version 1 posted 6 You are reading this latest preprint version Abstract Background: The goal of our study is to analyze the possible economic benefits of single-use flexible ureteroscopes (su-fURSs) and compare their cost effectiveness with that of reusable flexible ureteroscopes (re-fURSs) in secondary hospitals with an average patient flow rate. Methodes: The present study is a single-center, retrospective study conducted at Security Force Hospital, Makkah, Saudia Arabia. The study included data from all flexible ureteroscopy procedures performed in the urology department of the hospitals between June 2021 and December 2023. Karl Storz FLEX-X2S fiber-optic ureteroscopes were used for the procedures involving re-fURS, and the cost assessment took into account the initial cost of purchasing, the cost of reprocessing, and the cost of replacement split by the number of cases. This cost was compared with the costs of using WiScope (OTU Medical Inc.), a digital su-fURS. Results: Out of the total cases included in the study, 180 utilized su-fURSs, and 59 utilized re- fURSs with one repair exchange done during the observed study period. The average cost of using a re-fURS was approximately SAR 3,668 (USD 975) per case, while the cost of using a su- fURS was approximately SAR 1,650 (USD 438) per case. Conclusions: Su-fURS is a more cost-effective procedure than re-fURS performed in secondary hospitals with an average patient flow. Su-fURS may be more reliable than re-fURS regarding wear and tear. It is essential to consider different factors such as the cost of sterilization and the time spent in cleaning when determining which scope is most cost-effective for a particular procedure. Cost flexible ureteroscopy Introduction A flexible ureteroscope (fURS) is used frequently in daily urological practice. The flexibility of the device enables the detection and treatment of upper urinary tract diseases, including stones and upper urinary tract urothelial carcinomas [ 1 – 3 ]. A traditional fURS is reusable and must be decontaminated and disinfected before safely reusing. Unfortunately, sterilization methods take time and cost money in terms of products, materials, and labor [ 4 – 6 ]. With the increased usage of fURSs, many urologists face difficulties that may impact their performance, especially when fURSs need repair or exchange [ 7 – 10 ]. Single-use flexible ureteroscopes (su-fURS) are quickly improving the standard of care in endourology. The main drawbacks of reusable flexible ureteroscopes (re-fURS) are their high purchase and maintenance costs, risk of breakages, immediate availability, and need for reprocessing between procedures [ 11 ]. Fortunately, studies have found su-fURSs to have maneuverability, visual quality, and effectiveness comparable to re-fURSs [ 12 – 14 ]. However, due to a lack of competition and limited market share, the cost of su-fURSs is somewhat high, particularly compared to re-fURSs [ 15 ]. At the same time, re-fURSs have the added costs of repairing and purchasing. Using su-fURSs also decreases the risk of cross- infections and the need for sterilization between procedures. Moreover, some urologists believe that su-fURSs allow for more torque during the treatment of kidney stones without the increased danger of the device breaking [ 11 ]. Thus, the purpose of this study was to compare the costs of employing su-fURSs with re-fURSs in secondary hospitals with average patient volume. Patients and methods This retrospective study reports the data of a single center that included all flexible ureteroscopic procedures for treating renal stones performed in the urology department of Security Force Hospital, Makkah, Saudi Arabia, between June 2021 and December 2023. The local institutional IRB approval number for the study is 0535-301122. This study reported and compared the cost of su-fURSs and re-fURSs. It also reported the costs of purchasing both scopes and the costs of sterilization, maintenance, and repair of re-fURSs. Sample size calculation Sample size was calculated using G power 3.1.9.4 based on previous studies, we find mean ± SD (11053 ± 7821) $ for group I and mean ± SD (13284 ± 7821) $ for group II. With a power of 80% (using t test and alpha of 0.05). As this study will be carried out on 2 arms . The sample needed for the study was estimated to be 50 patients each arm. Operating costs of reusable ureteroscopes When evaluating the cost of re-fURSs, the costs of ureteroscope procurement, maintenance, repair, and operating expenses, which included decontamination and sterilization, were reported. Hospital staff centrally prepared and sterilized all re-fURS using a steam sterilization unit. Inspection, preliminary cleaning, disinfection, and sterilization were all part of the reprocessing protocol. If damage to the re-fURS was discovered during inspection, the re- fURS was sent back to the original manufacturer for assessment and repair, and a replacement re-fURS made available by the original manufacturer was put into use. The central services billing division reported the reprocessing expenses of re-fURS per case. The hourly salaries of the sterilization technicians and an assessment of the average time needed to reprocess the re-fURS were used to estimate labor expenses. The next step in re-fURS processing is sterilization and repacking. This procedure, which involved cleaning, rinsing, disinfecting, drying, and reconditioning brushes, was carried out in the hospital's sterilization room. The last step is transporting the scope to the operating room. In all, the cost of materials and labor for decontamination, repackaging, and transport for each re- fURS was calculated. The total cost of re-fURS used per procedure was calculated using the following formula: Total cost per case = (total purchase and exchange costs/number of cases) + (cost of reprocessing or recycling each case). Operating expenses included costs for decontamination, transportation, and storage. After each procedure, a ureteroscope is first treated in the operating room with wiping, aspiration, and tightness tests. In the sterilizing room, ureteroscopes are cleaned, rinsed, disinfected with peracetic acid, dried, and repackaged as the second stage in processing. The final step in reusable fURS processing is transportation from the decontamination room to the operation room. Cost of single-use ureteroscopes Su-fURSs don't need to be cleaned or reconditioned before use because they come in sterile packs. The only expense reported is the cost of buying them. In the present study, the waste processing of su-fURSs should have been considered. The cost of digital su-fURS was based on market data as of June 2021 (approximately SAR 1,650 (USD 438) per su-fURS. The total cost of a su-fURS was calculated using the following formula: Total cost (y) = (cost of purchase of each su-fURS + 15% VAT) × (number of procedures (x)). The currency of choice for cost comparison was the Saudi Arabian Riyal (SAR). Thanks to this study, our hospital improved its practices by utilizing a hybrid strategy that mixes re-fURSs and su-fURSs. In this strategy, su-fURSs take the role of traditional re-fURSs in circumstances where there is a high danger of infection transmission or a high risk of scope damage (complex stones, stones in the inferior calyx, urine diversion, etc.). Results The study included 239 ureteroscopic procedures performed in the Security Force Hospital, Makkah, in the period between June 2021 and December 2023. A fiber-optic (Flex X2S, Storz®) re-fURS was used in 59 procedures (Group A) and WiScope (OTU Medical Inc.) su- fURSs were used in 180 cases (Group B). No stastistical significant differences were observed between both groups regarding preoperative demographic data and regarding stone burden (20±14 mm, vs 27± 9 mm , P= 0.63). Equivalent Stone free rate was reported in both groups ( 48 cases in group A and 151 case in group B , P= 0.8). As regard re operation of residual stones, 15 patients were re-operated in group A and 29 patients were re-operated in group B , P=0.16. Twelve patients in group A had renal pelvic stone and 30 patients in group B had stones located in renal pelvis (P= 0.95). (Table 2) One new re- fURS was used at the beginning of the study. The original purchase price of the re- fURS was SAR 98,876 ($26,296). This re- FURS was damaged during the study and was replaced with a new one. The cost of exchanging a broken re-fURS with a new one was SAR 82,178 (USD 21,855). There were no significant differences in patient demographics or stone characteristics between the two groups. ( Table 1). The reprocessing of re- fURS includes scope cleaning, rinsing, disinfecting, drying, and reconditioning brushes. The last step is transporting the scope to the operating room. The cost of materials and labor for decontamination, repackaging, and transport for each re-fURS was also calculated, and it was determined to be approximately SAR 600 (USD 159) per procedure. The overall cost of a re-fURS, including the initial purchase cost, the cost of exchanging a broken re-fURS, and reprocessing and labor charges, was 216,454 (USD 57,567) throughout the study period. June 2021, our institution purchased 180 WiScope® su-fURSs for SAR 297,000 (USD 78,989), including a 15% sales tax. The average cost of using a su-fURS was calculated to be approximately SAR 1,650 (USD 438) per case, while the cost of using a re-fURS was calculated to be approximately SAR 3,668 (USD 975) per case. Thus, su-fURSs are more cost-effective than re-fURSs. Table (1,2). In present study, in the re- FURS group, the scope was damaged in one case that was completed with another new Su- FURS. In the Su FURS group, the scope was damaged in two cases that were completed by another new Su FURS scopes. Discussion Due to improvements in the production of fURSs, flexible ureteroscopy is the preferred method of treating upper urinary tract stones [ 1 , 16 ]. However, there have consistently been worries about the high price [ 17 ]. The price of the flexible ureteroscope technique includes the cost of the laser used for stone fragmentation, the pay of the staff members responsible for cleaning and sterilization procedures, and all accessory tools used during the treatment. Institutions may also encounter severe delays in repairing or exchanging broken re-fURS [ 16 , 17 ]. On the other hand, su-fURSs may offer solutions for the problems mentioned above, particularly in reducing the cost of repairing and replacing re-fURSs [ 18 ]. According to a few randomized controlled trials, FURSs are brittle and necessitate high maintenance and repair expenses [ 19 , 20 ]. A digital fURS is typically used 21 times before requiring a repair, and a fiber-optic ureteroscope is typically used 6 to 15 times before being returned to its maker [ 7 , 21 ]. Legemate et al. [ 22 ] reported that digital re-fURSs had more extended durability (mean: 27; 20–56) compared to fiber-optic fURSs (mean: 24; 10–37), but the average durability of re-fURSs ranged from 3 to 11 cases [ 9 , 23 – 25 ]. Another study concluded that not only are new fURSs more resistant to malfunction (mean: 44) than refurbished devices, but the new re-furs last longer if they are maintained and repaired by the original maker (mean: 11.1) than by outside contractors (mean: 6.9) [ 9 ]. Previous studies have tested the first generation of su-fURSs, but suboptimal surgical effects prevent their inclusion into daily practice [ 26 – 28 ]. However, newer su-fURS provide similar clinical efficacy and maneuverability to reusable scopes and are now part of routine daily practice in urology [ 13 , 29 – 34 ]. Since su-fURSs don't need to be repaired, maintained, or sterilized, and the stock is managed by a hospital's pharmacy, one of their key benefits is accessibility and availability [ 18 , 35 ]. Despite adherence to the decontamination and sterilization processes of reusable ureteroscopes, risks of infection and cross-contamination exist. Ofstead et al. analyzed 16 re-fURS procedures in two different centers, finding that despite disinfection procedures, all the re-fURSs had visible damage and were contaminated with hemoglobin, protein, or microbial growth. There is no such risk with su-fURSs [ 5 ]. Various studies have reported on the incidence rate of re-fURS breakage that occurs during storage or processing, finding that 7.7–22% of the time, re-fURSs are damaged even in the hands of qualified staff [ 8 , 21 , 26 , 29 ]. Abraham et al. studied two identical fiber-optic re-fURSs that undergo sterilization through different sterilization processes. The first ureteroscope, sterilized with the Steris system, had 297 broken fibers, a 12-mm tear on its shaft, and a 37% loss in resolution after 100 sterilization cycles, according to the authors. Ten damaged fibers were found in the second re-fURS, which had been Cidex sterilized [ 36 ]. In our hospital, re-fURS re-sterilization involves three hours of labor and three paramedical personnel, while su-fURSs are stored in a sterile package in the operating room. The su-fURS are delivered to a burning device after each treatment. The price of buying, repairing, and sterilizing the scope must be factored into the total cost of re- fURSs. A modern re-fURS (Flex-X, Karl Storz, Germany) costs USD 13,611, according to a recent study [ 37 ]. In a recent Australian study, the digital Olympus URF-V was purchased for USD 20,200 [ 15 ]. The cost of reprocessing this device includes paying employees (nurses, technicians, etc.) and buying supplies for cleaning, sterilization, packaging, and leakage testing. Recent cost analyses indicated that the cost of reprocessing ranged from USD 19.90 to USD 108.00 per case if the price of purchasing a STERRAD machine (a system that uses low-temperature hydrogen peroxide gas plasma technology to sterilize) is not taken into account [ 15 , 37 – 39 ]. In the present study, the average cost for re-FURS was approximately SAR 3,668 (USD 975) per case, and the price for su-fURS was approximately SAR 1,650 (USD 438) per case, that did not change from 2022 till end of 2024. Tagushi et al. reported a USD 3.65 recycling cost per re-fURS of the type used in their study [ 40 ]. The purchase cost of a su-fURS is always a concerning issue. The business agreement between the manufacturer and the hospital has the most significant impact. LithoVueTM [ 15 , 33 , 41 ], PolyscopeTM [ 42 ], and SemiFlexTM [ 30 ] have reported purchase prices ranging from USD 1,300 to USD 3,180, USD 700, and USD 800, respectively. More su-fURSs will be well-spent as production technology develops, perhaps lowering final retail pricing. As more manufacturers vie for market share, sales prices could also drop (Sales prices may decrease as more manufacturers compete for market share). Martin et al. conducted a cost-benefit analysis on all available fURSs to determine the cost of re- fURSs. They reported a cost of USD 848.10 per case and favored the purchase of re-fURSs when more than 99 procedures a year were being performed at a hospital, suggesting that re-fURSs are more cost-effective in high-volume institutions [ 43 ]. Similarly, Mager et al. conducted a cost- analysis study to evaluate the expenses of fURSs. The study reported that the cost of re-fURS ranged between USD 436 and USD 708 per case. When the initial purchasing costs were added, the total cost increased to $ 1,212–USD 1,743 per case. Based on data and studies, LithoVueTM procedures range in price from USD 1,300 (market pricing) to USD 3,180 (manufacturer's recommended wholesale price) per case. Mager et al. discovered in a prediction model that the routine use of su-fURSs would be more costly than the routine usage of re-fURSs after executing 61 to 118 examples [ 38 ]. In a German case series, Ozimek et al. reported 321 cases of kidney stone treatment and 102 diagnostic fURS surgeries. On average, 14.4 incidents resulted in scope damage, and all operations cost a total of USD 261,332. The calculated average cost per fURS procedure was USD 617.40. Ozimek et al. concluded that the use of re-fURSs was cost-effective when compared to the use of su-fURSs since the price of a LithoVueTM device was USD 1,227.50 [ 44 ]. According to Hennessey et al., the mean cost per case for seven new digital re-fURSs utilized over 30 months was USD 533 (USD 276-USD 904), and the overall repair cost for these devices was USD 124,800. The increasing cost of 28 cases using re-fURSs was USD 38,360. For a su- fURS (LithoVueTM) that costs USD 1,918, the total cost would be USD 55,239 for the same 28 cases; thus, the re-fURSs would be more economical. Conversely, if the cost of su-fURSs were USD 920, then the cost for 28 cases would be USD 26,850, which would be a considerable economic, saving [ 15 ]. Study limitation The present study has some limitation including, the expense of maintaining room sterilization was not considered in the current analysis, which would have increased the price of processing re-fURSs. Another limitation of this study is that the waste processing of su-fURSs was not included in the cost analysis. Additionally, post operative possible infection and its treatment cost that may include hospital readmission were not evaluated in the study. Conclusions Several factors affect the cost analysis of su-fURSs compared to re-fURSs, such as the number and type of procedures and equipment cost. When considering the cost of sterilization and the time spent in cleaning, su-fURS may be more cost-effective than re-fURS in secondary hospitals with an average flow rate of patients. Moreover, su-fURS may be more reliable than re-fURS regarding wear and tear. Finally, it is essential to consider all these factors when determining which scope is most cost-effective for a particular procedure. Abbreviations fURS: flexible ureteroscope SAR: Saudi Arabian Riyal USD: United States Dollar su-fURS: single-use flexible ureteroscope re-fURS: reusable flexible ureteroscope Declarations Ethics approval : IRB approval number (0535301122- Security Force Hospital / Makkah. Saudia Arabia) Consent for publication: Consent for publication was obtained Funding: None Conflict of interrest : there are no financial or institutional conflicts of interest influencing the present study. Author Contribution A. I. A.: Idea owner, helped in writing the manuscript, data collectionA. A: helped in writing manuscriptS. A. K.: writing the manuscript and data collectionA. T.: data collectionA. A. : Data collectionW. A.: Data collectionA. M.: writing manuscriptA. B: data collectionS. A.: data collectionA.H.: writing manuscript, data collection References Türk, , et al., EAU guidelines on interventional treatment for urolithiasis. European urology, 2016. 69 (3): p. 475-482. Rouprêt, , et al., European Association of Urology guidelines on upper urinary tract urothelial carcinoma: 2020 update. European urology, 2021. 79 (1): p. 62-79. Seisen, T., et al., Oncologic outcomes of kidney-sparing surgery versus radical nephroureterectomy for upper tract urothelial carcinoma: a systematic review by the EAU non- muscle invasive bladder cancer guidelines panel. European urology, 2016. 70 (6): p. 1052-1068. Semins, J., et al., Ureteroscope cleaning and sterilization by the urology operating room team: the effect on repair costs. Journal of endourology, 2009. 23 (6): p. 903-905. Ofstead, L., et al., The effectiveness of sterilization for flexible ureteroscopes: A real-world study. American journal of infection control, 2017. 45 (8): p. 888-895. Sabnis, B., A. Bhattu, and V. Mohankumar, Sterilization of endoscopic instruments. Current Opinion in Urology, 2014. 24 (2): p. 195-202. Karaolides, , et al., Improving the durability of digital flexible ureteroscopes. Urology, 2013. 81 (4): p. 717-722. Carey, I., et al., Frequency of ureteroscope damage seen at a tertiary care center. The Journal of urology, 2006. 176 (2): p. 607-610. Carey, R.I., C.J. Martin, and J.R. Knego, Prospective evaluation of refurbished flexible ureteroscope durability seen in a large public tertiary care center with multiple Urology, 2014. 84 (1): p. 42-45. Legemate, J.D., et al., Durability of flexible ureteroscopes: a prospective evaluation of longevity, the factors that affect it, and damage European urology focus, 2019. 5 (6): p. 1105- 1111. Ventimiglia, , B.K. Somani, and O. Traxer, Flexible ureteroscopy: reuse? Or is single use the new direction? Current Opinion in Urology, 2020. 30 (2): p. 113-119. Schlager, , et al., Performance of single-use flexorvue vs reusable boavision ureteroscope for visualization of calices and stone extraction in an artificial kidney model. Journal of endourology, 2017. 31 (11): p. 1139-1144. Proietti, S., et al., Comparison of new single-use digital flexible ureteroscope versus nondisposable fiber optic and digital ureteroscope in a cadaveric Journal of endourology, 2016. 30 (6): p. 655-659. Ventimiglia, , et al., Cost comparison of single-use versus reusable flexible ureteroscope: A systematic review. Turkish journal of urology, 2020. 46 (Suppl 1): p. S40. Hennessey, B., et al., Single-use disposable digital flexible ureteroscopes: an ex vivo assessment and cost analysis. BJU international, 2018. 121 : p. 55-61. Assimos, , et al., Surgical management of stones: American urological association/endourological society guideline, PART I. The Journal of urology, 2016. 196 (4): p. 1153-1160. Somani, K., et al., Outcomes of flexible ureterorenoscopy and laser fragmentation for renal stones: comparison between digital and conventional ureteroscope. Urology, 2013. 82 (5): p. 1017-1019. Emiliani, and O. Traxer, Single use and disposable flexible ureteroscopes. Current opinion in urology, 2017. 27 (2): p. 176-181. Knudsen, , et al., Durability of the next-generation flexible fiberoptic ureteroscopes: a randomized prospective multi-institutional clinical trial. Urology, 2010. 75 (3): p. 534-538. Monga, , et al., durability of flexible ureteroscopes: a randomized, prospective study. The Journal of urology, 2006. 176 (1): p. 137-141. AFANE, S., et al., Flexible ureteroscopes: a single center evaluation of the durability and function of the new endoscopes smaller than 9Fr. The Journal of urology, 2000. 164 (4): p. 1164- 1168. Legemate, D., et al., Pre-use ureteroscope contamination after high level disinfection: reprocessing effectiveness and the relation with cumulative ureteroscope use. The Journal of Urology, 2019. 201 (6): p. 1144-1151. Binbay, , et al., Is there a difference in outcomes between digital and fiberoptic flexible ureterorenoscopy procedures? Journal of endourology, 2010. 24 (12): p. 1929-1934. Collins, , F. Keeley, and A. Timoney, Cost analysis of flexible ureterorenoscopy. BJU international, 2004. 93 (7): p. 1023-1026. User, M., et al., Performance and durability of leading flexible ureteroscopes. Journal of endourology, 2004. 18 (8): p. 735-738. Ding, , et al., Comparing the efficacy of a multimodular flexible ureteroscope with its conventional counterpart in the management of renal stones. Urology, 2015. 86 (2): p. 224-229. Gu, S.-P., et al., Clinical effectiveness of the PolyScope™ endoscope system combined with holmium laser lithotripsy in the treatment of upper urinary calculi with a diameter of less than 2 cm. Experimental and therapeutic medicine, 2013. 6 (2): p. 591-595. Bansal, , et al., Polyscope: a new era in flexible ureterorenoscopy. Journal of endourology, 2011. 25 (2): p. 317-321. Usawachintachit, , et al., A prospective case–control study comparing LithoVue, a single-use, flexible disposable ureteroscope, with flexible, reusable fiber-optic ureteroscopes. Journal of endourology, 2017. 31 (5): p. 468-475. Boylu, , et al., In vitro comparison of a disposable flexible ureteroscope and conventional flexible ureteroscopes. The Journal of urology, 2009. 182 (5): p. 2347-2351. Salvadó, A., et al., Clinical Comparison between Three Single-Use Flexible Ureteroscope Models: A Real-World Experience. Urologia Internationalis, 2022. 106 (12): p. 1220-1225. Dale, , et al., Evaluation of a novel single-use flexible ureteroscope. Journal of endourology, 2021. 35 (6): p. 903-907. Ghodoussipour, , et al., Mp50-08 Limitations of the lithovue single use digital flexible ureteroscope. The Journal of Urology, 2017. 197 (4S): p. e686-e687. Tom, R., et al., Next-generation single-use ureteroscopes: an in vitro comparison. Journal of endourology, 2017. 31 (12): p. 1301-1306. Davis, , et al., Single-use flexible ureteropyeloscopy: a systematic review. World Journal of Urology, 2018. 36 : p. 529-536. Marchini, S., et al., A comprehensive literature-based equation to compare cost-effectiveness of a flexible ureteroscopy program with single-use versus reusable devices. International braz j urol, 2019. 45 : p. 658-670. Gurbuz, , et al., The cost analysis of flexible ureteroscopic lithotripsy in 302 cases. Urolithiasis, 2014. 42 : p. 155-158. Mager, R., et al., Clinical outcomes and costs of reusable and single-use flexible ureterorenoscopes: a prospective cohort study. Urolithiasis, 2018. 46 : p. 587-593. Isaacson, , et al., Defining the costs of reusable flexible ureteroscope reprocessing using time- driven activity-based costing. Journal of endourology, 2017. 31 (10): p. 1026-1031. Taguchi, , et al., Micro-costing analysis demonstrates comparable costs for LithoVue compared to reusable flexible fiberoptic ureteroscopes. Journal of endourology, 2018. 32 (4): p. 267-273. Stern, M., J. Yiee, and S. Park, Safety and efficacy of ureteral access sheaths. Journal of endourology, 2007. 21 (2): p. 119-123. Siu, J.-Y., et al., The Cost-Effectiveness of Treatment Modalities for Ureteral Stones: A National Comprehensive Study. INQUIRY: The Journal of Health Care Organization, Provision, and Financing, 2016. 53 : p. 0046958016669015. Martin, J., et al., The economic implications of a reusable flexible digital ureteroscope: a cost- benefit analysis. The Journal of urology, 2017. 197 (3): p. 730-735. Ozimek, , et al., Retrospective cost analysis of a single-center reusable flexible ureterorenoscopy program: a comparative cost simulation of disposable fURS as an alternative. Journal of Endourology, 2017. 31 (12): p. 1226-1230. Tables Table 1 and 2 are available in the Supplementary Files section. Additional Declarations No competing interests reported. Supplementary Files Table1113.docx Table2.docx ethical.pdf Cite Share Download PDF Status: Published Journal Publication published 18 Jun, 2025 Read the published version in African Journal of Urology → Version 1 posted Editorial decision: Accepted 02 Jun, 2025 Reviews received at journal 26 May, 2025 Reviewers agreed at journal 26 May, 2025 Reviewers invited by journal 26 May, 2025 Submission checks completed at journal 25 May, 2025 First submitted to journal 25 May, 2025 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-5069441","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Research Article","associatedPublications":[],"authors":[{"id":462411321,"identity":"d4f4b58a-84f6-47ab-804e-dde08905a9f1","order_by":0,"name":"Ahmed Ali","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAABCElEQVRIiWNgGAWjYDACCSDmMQCxGBsf/6mwATMOEKmFudmA50waSEsDEVrALPY2Cd62w2AmXi38s7sTH7wpqLPnn3awTUKy7bzd2vbDQFtqbKJxWnLn7GbDOQaHE2fcTmy2MDh3O3nbmUSglmNpuQ249NzI3SbNY3AggeF2YuONhLLbyWYHgFoYGw7j1CJ/I3f7bx6DOnv524kNEgfYziWbnX+IX4sB0BZmHgNmxg23E5skG9oO2JndIGCL4Y3czZIgv2wE+sWY4UxygtkNoC0JePwidyN344c3f+rs5W6nP3zMUGFnb3Y+/eGDDzU2uL2PDhLBKhOIVQ4C9qQoHgWjYBSMgpEBACQja1XBEhomAAAAAElFTkSuQmCC","orcid":"","institution":"Minia University Hospital","correspondingAuthor":true,"prefix":"","firstName":"Ahmed","middleName":"","lastName":"Ali","suffix":""},{"id":462411322,"identity":"f6bcecc4-d963-4275-8ada-95ec5f05893f","order_by":1,"name":"Abdelsalam Abdelfadel","email":"","orcid":"","institution":"Minia University Hospital","correspondingAuthor":false,"prefix":"","firstName":"Abdelsalam","middleName":"","lastName":"Abdelfadel","suffix":""},{"id":462411323,"identity":"c8cebbc4-fe39-41b3-a300-a47b0bbe7ca2","order_by":2,"name":"Suhail Kalantan","email":"","orcid":"","institution":"Security Forces Hospital","correspondingAuthor":false,"prefix":"","firstName":"Suhail","middleName":"","lastName":"Kalantan","suffix":""},{"id":462411326,"identity":"e782d82f-9b32-4a40-938f-e651434bb708","order_by":3,"name":"Amer Azzam","email":"","orcid":"","institution":"Damanhour medical national institution","correspondingAuthor":false,"prefix":"","firstName":"Amer","middleName":"","lastName":"Azzam","suffix":""},{"id":462411327,"identity":"98e77ade-241f-4404-aa14-671c3d3dda45","order_by":4,"name":"A Albkri","email":"","orcid":"","institution":"Security Forces Hospital","correspondingAuthor":false,"prefix":"","firstName":"A","middleName":"","lastName":"Albkri","suffix":""},{"id":462411328,"identity":"5a5498de-1fbd-4b70-b162-5ba587d48a51","order_by":5,"name":"Waleed Alhozali","email":"","orcid":"","institution":"Alnoor Hospital","correspondingAuthor":false,"prefix":"","firstName":"Waleed","middleName":"","lastName":"Alhozali","suffix":""},{"id":462411329,"identity":"b50973d9-3654-4ef8-9db5-26beaa3a8102","order_by":6,"name":"Adel Moalwi","email":"","orcid":"","institution":"NAJRAN UNIVERSITY","correspondingAuthor":false,"prefix":"","firstName":"Adel","middleName":"","lastName":"Moalwi","suffix":""},{"id":462411330,"identity":"8e8c0130-517c-4b38-8adf-e560b3d04e56","order_by":7,"name":"Abdulaziz Bakhsh","email":"","orcid":"","institution":"Taibah University","correspondingAuthor":false,"prefix":"","firstName":"Abdulaziz","middleName":"","lastName":"Bakhsh","suffix":""},{"id":462411331,"identity":"5241c026-d6a8-41e2-b68f-d8737c58289b","order_by":8,"name":"Sarah Ali","email":"","orcid":"","institution":"Minia University Hospital","correspondingAuthor":false,"prefix":"","firstName":"Sarah","middleName":"","lastName":"Ali","suffix":""},{"id":462411332,"identity":"69f7a2e9-1512-48c3-bb34-92b74ddaf9bf","order_by":9,"name":"Ali Hassan","email":"","orcid":"","institution":"Minia University Hospital","correspondingAuthor":false,"prefix":"","firstName":"Ali","middleName":"","lastName":"Hassan","suffix":""}],"badges":[],"createdAt":"2024-09-11 08:25:21","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-5069441/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-5069441/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1186/s12301-025-00510-0","type":"published","date":"2025-06-18T15:57:14+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":85231405,"identity":"71bb63d2-9739-4b1b-951b-d16ef874d62f","added_by":"auto","created_at":"2025-06-23 16:07:23","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":524774,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-5069441/v1/5d17865a-b209-4719-8a38-97fbae491efa.pdf"},{"id":83540800,"identity":"8ec72d26-d263-4f8b-82c6-636845c54fb8","added_by":"auto","created_at":"2025-05-28 08:00:24","extension":"docx","order_by":0,"title":"","display":"","copyAsset":false,"role":"supplement","size":12605,"visible":true,"origin":"","legend":"","description":"","filename":"Table1113.docx","url":"https://assets-eu.researchsquare.com/files/rs-5069441/v1/9dfa0909222ef1819fc3eeba.docx"},{"id":83540127,"identity":"cf42bbc8-7f31-4760-a0ec-9bf3c2bf0aff","added_by":"auto","created_at":"2025-05-28 07:52:24","extension":"docx","order_by":1,"title":"","display":"","copyAsset":false,"role":"supplement","size":16701,"visible":true,"origin":"","legend":"","description":"","filename":"Table2.docx","url":"https://assets-eu.researchsquare.com/files/rs-5069441/v1/47bd0ee4bef1c515b2d175b1.docx"},{"id":83540132,"identity":"e9b56b4d-8d0d-4251-b0bf-40dcc84a066c","added_by":"auto","created_at":"2025-05-28 07:52:24","extension":"pdf","order_by":2,"title":"","display":"","copyAsset":false,"role":"supplement","size":205139,"visible":true,"origin":"","legend":"","description":"","filename":"ethical.pdf","url":"https://assets-eu.researchsquare.com/files/rs-5069441/v1/7bcb23714fbe8008f5708c4b.pdf"}],"financialInterests":"No competing interests reported.","formattedTitle":"Economic evaluation of a Single use Flexible Digital Ureteroscope : Cost Analysis","fulltext":[{"header":"Introduction","content":"\u003cp\u003eA flexible ureteroscope (fURS) is used frequently in daily urological practice. The flexibility of the device enables the detection and treatment of upper urinary tract diseases, including stones and upper urinary tract urothelial carcinomas [\u003cspan additionalcitationids=\"CR2\" citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR3\" class=\"CitationRef\"\u003e3\u003c/span\u003e]. A traditional fURS is reusable and must be decontaminated and disinfected before safely reusing. Unfortunately, sterilization methods take time and cost money in terms of products, materials, and labor [\u003cspan additionalcitationids=\"CR5\" citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR6\" class=\"CitationRef\"\u003e6\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eWith the increased usage of fURSs, many urologists face difficulties that may impact their performance, especially when fURSs need repair or exchange [\u003cspan additionalcitationids=\"CR8 CR9\" citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR10\" class=\"CitationRef\"\u003e10\u003c/span\u003e]. Single-use flexible\u003c/p\u003e \u003cp\u003eureteroscopes (su-fURS) are quickly improving the standard of care in endourology. The main drawbacks of reusable flexible ureteroscopes (re-fURS) are their high purchase and maintenance costs, risk of breakages, immediate availability, and need for reprocessing between procedures [\u003cspan citationid=\"CR47\" class=\"CitationRef\"\u003e11\u003c/span\u003e]. Fortunately, studies have found su-fURSs to have maneuverability, visual quality, and effectiveness comparable to re-fURSs [\u003cspan additionalcitationids=\"CR13\" citationid=\"CR12\" class=\"CitationRef\"\u003e12\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eHowever, due to a lack of competition and limited market share, the cost of su-fURSs is somewhat high, particularly compared to re-fURSs [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e]. At the same time, re-fURSs have the added costs of repairing and purchasing. Using su-fURSs also decreases the risk of cross- infections and the need for sterilization between procedures. Moreover, some urologists believe that su-fURSs allow for more torque during the treatment of kidney stones without the increased danger of the device breaking [\u003cspan citationid=\"CR47\" class=\"CitationRef\"\u003e11\u003c/span\u003e]. Thus, the purpose of this study was to compare the costs of employing su-fURSs with re-fURSs in secondary hospitals with average patient volume.\u003c/p\u003e"},{"header":"Patients and methods","content":"\u003cp\u003eThis retrospective study reports the data of a single center that included all flexible ureteroscopic procedures for treating renal stones performed in the urology department of Security Force Hospital, Makkah, Saudi Arabia, between June 2021 and December 2023. The local institutional IRB approval number for the study is 0535-301122.\u003c/p\u003e \u003cp\u003eThis study reported and compared the cost of su-fURSs and re-fURSs. It also reported the costs of purchasing both scopes and the costs of sterilization, maintenance, and repair of re-fURSs.\u003c/p\u003e \u003cdiv id=\"Sec3\" class=\"Section2\"\u003e \u003ch2\u003eSample size calculation\u003c/h2\u003e \u003cp\u003eSample size was calculated using G power 3.1.9.4 based on previous studies, we find mean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD (11053\u0026thinsp;\u0026plusmn;\u0026thinsp;7821) \u003cspan\u003e$\u003c/span\u003e for group I and mean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD (13284\u0026thinsp;\u0026plusmn;\u0026thinsp;7821) \u003cspan\u003e$\u003c/span\u003e for group II. With a power of 80% (using t test and alpha of 0.05). As this study will be carried out on \u003cb\u003e2 arms\u003c/b\u003e. The sample needed for the study was estimated to be 50 patients each arm.\u003c/p\u003e \u003c/div\u003e\n\u003ch3\u003eOperating costs of reusable ureteroscopes\u003c/h3\u003e\n\u003cp\u003eWhen evaluating the cost of re-fURSs, the costs of ureteroscope procurement, maintenance, repair, and operating expenses, which included decontamination and sterilization, were reported.\u003c/p\u003e \u003cp\u003eHospital staff centrally prepared and sterilized all re-fURS using a steam sterilization unit. Inspection, preliminary cleaning, disinfection, and sterilization were all part of the reprocessing protocol. If damage to the re-fURS was discovered during inspection, the re- fURS was sent\u003c/p\u003e \u003cp\u003eback to the original manufacturer for assessment and repair, and a replacement re-fURS made available by the original manufacturer was put into use.\u003c/p\u003e \u003cp\u003eThe central services billing division reported the reprocessing expenses of re-fURS per case. The hourly salaries of the sterilization technicians and an assessment of the average time needed to reprocess the re-fURS were used to estimate labor expenses.\u003c/p\u003e \u003cp\u003eThe next step in re-fURS processing is sterilization and repacking. This procedure, which involved cleaning, rinsing, disinfecting, drying, and reconditioning brushes, was carried out in the hospital's sterilization room. The last step is transporting the scope to the operating room. In all, the cost of materials and labor for decontamination, repackaging, and transport for each re- fURS was calculated.\u003c/p\u003e \u003cp\u003eThe total cost of re-fURS used per procedure was calculated using the following formula:\u003c/p\u003e \u003cp\u003eTotal cost per case = (total purchase and exchange costs/number of cases) + (cost of reprocessing or recycling each case).\u003c/p\u003e \u003cp\u003eOperating expenses included costs for decontamination, transportation, and storage. After each procedure, a ureteroscope is first treated in the operating room with wiping, aspiration, and\u003c/p\u003e \u003cp\u003etightness tests. In the sterilizing room, ureteroscopes are cleaned, rinsed, disinfected with\u003c/p\u003e \u003cp\u003eperacetic acid, dried, and repackaged as the second stage in processing. The final step in reusable fURS processing is transportation from the decontamination room to the operation room.\u003c/p\u003e\n\u003ch3\u003eCost of single-use ureteroscopes\u003c/h3\u003e\n\u003cp\u003eSu-fURSs don't need to be cleaned or reconditioned before use because they come in sterile packs. The only expense reported is the cost of buying them. In the present study, the waste processing of su-fURSs should have been considered.\u003c/p\u003e \u003cp\u003eThe cost of digital su-fURS was based on market data as of June 2021 (approximately SAR 1,650 (USD 438) per su-fURS. The total cost of a su-fURS was calculated using the following formula:\u003c/p\u003e \u003cp\u003eTotal cost (y) = (cost of purchase of each su-fURS\u0026thinsp;+\u0026thinsp;15% VAT) \u0026times; (number of procedures (x)). The currency of choice for cost comparison was the Saudi Arabian Riyal (SAR).\u003c/p\u003e \u003cp\u003eThanks to this study, our hospital improved its practices by utilizing a hybrid strategy that mixes re-fURSs and su-fURSs. In this strategy, su-fURSs take the role of traditional re-fURSs in circumstances where there is a high danger of infection transmission or a high risk of scope damage (complex stones, stones in the inferior calyx, urine diversion, etc.).\u003c/p\u003e"},{"header":"Results","content":"\u003cp\u003eThe study included 239 ureteroscopic procedures performed in the Security Force Hospital, Makkah,\u0026nbsp;in\u0026nbsp;the\u0026nbsp;period\u0026nbsp;between\u0026nbsp;June\u0026nbsp;2021\u0026nbsp;and\u0026nbsp;December\u0026nbsp;2023. A\u0026nbsp;fiber-optic\u0026nbsp;(Flex\u0026nbsp;X2S,\u0026nbsp;Storz\u0026reg;)\u0026nbsp;re-fURS\u0026nbsp;was\u0026nbsp;used\u0026nbsp;in 59 procedures (Group A) and WiScope\u0026nbsp;(OTU\u0026nbsp;Medical\u0026nbsp;Inc.)\u0026nbsp;su- fURSs\u0026nbsp;were\u0026nbsp;used\u0026nbsp;in\u0026nbsp;180\u0026nbsp;cases (Group B).\u003c/p\u003e\n\u003cp\u003eNo stastistical significant differences were observed between both groups regarding preoperative demographic data and regarding stone burden (20\u0026plusmn;14 mm, vs 27\u0026plusmn; 9 mm , P= 0.63). \u0026nbsp;Equivalent Stone free \u0026nbsp;rate was reported in both groups ( 48 cases in group A and 151 case in group B , P= 0.8). As regard re operation of residual stones, 15 patients were re-operated in group A and 29 patients were re-operated in group B , P=0.16. Twelve patients in group A had renal pelvic stone and 30 patients in group B had stones located in renal pelvis (P= 0.95). (Table 2)\u003c/p\u003e\n\u003cp\u003eOne new re- fURS was used at the beginning of the study. The original purchase price of the re- fURS was SAR 98,876 ($26,296). This re- FURS was damaged during the study and was replaced with a new one. The cost of exchanging a broken re-fURS with a new one was SAR 82,178 (USD 21,855). There were no significant differences in patient demographics or stone\u003c/p\u003e\n\u003cp\u003echaracteristics\u0026nbsp;between\u0026nbsp;the\u0026nbsp;two\u0026nbsp;groups. ( Table 1).\u003c/p\u003e\n\u003cp\u003eThe reprocessing of re- fURS includes scope cleaning, rinsing, disinfecting, drying, and reconditioning\u0026nbsp;brushes.\u0026nbsp;The\u0026nbsp;last\u0026nbsp;step\u0026nbsp;is\u0026nbsp;transporting\u0026nbsp;the\u0026nbsp;scope\u0026nbsp;to\u0026nbsp;the\u0026nbsp;operating\u0026nbsp;room.\u0026nbsp;The\u0026nbsp;cost\u0026nbsp;of materials and labor for decontamination, repackaging, and transport for each re-fURS was also calculated, and it was determined to be approximately SAR 600 (USD 159) per procedure.\u003c/p\u003e\n\u003cp\u003eThe overall cost of a re-fURS, including the initial purchase cost, the cost of exchanging a\u0026nbsp;broken re-fURS, and reprocessing and labor charges, was 216,454 (USD\u0026nbsp;57,567) throughout the study period.\u003c/p\u003e\n\u003cp\u003eJune 2021, our institution purchased 180 WiScope\u0026reg; su-fURSs for SAR 297,000 (USD 78,989), including a 15% sales tax. The average cost of using a su-fURS was calculated to be approximately SAR 1,650 (USD 438) per case, while the cost of using a re-fURS was calculated to be approximately SAR 3,668 (USD 975) per case. Thus, su-fURSs are more cost-effective than re-fURSs. Table (1,2).\u0026nbsp;\u003c/p\u003e\n\u003cp\u003e\u0026nbsp;In present study, in the \u0026nbsp;re- FURS group, the scope was damaged in one case that was completed with another new Su- FURS. In the Su FURS group, the scope was damaged in two cases that were completed by another new Su FURS scopes.\u003c/p\u003e"},{"header":"Discussion","content":"\u003cp\u003eDue to improvements in the production of fURSs, flexible ureteroscopy is the preferred method of treating upper urinary tract stones [\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e, \u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e16\u003c/span\u003e]. However, there have consistently been worries about the high price [\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e]. The price of the flexible ureteroscope technique includes the cost of the laser used for stone fragmentation, the pay of the staff members responsible for cleaning and sterilization procedures, and all accessory tools used during the treatment. Institutions may also encounter severe delays in repairing or exchanging broken re-fURS [\u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e16\u003c/span\u003e, \u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eOn the other hand, su-fURSs may offer solutions for the problems mentioned above, particularly in reducing the cost of repairing and replacing re-fURSs [\u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e]. According to a few randomized controlled trials, FURSs are brittle and necessitate high maintenance and repair expenses [\u003cspan citationid=\"CR19\" class=\"CitationRef\"\u003e19\u003c/span\u003e, \u003cspan citationid=\"CR20\" class=\"CitationRef\"\u003e20\u003c/span\u003e]. A digital fURS is typically used 21 times before requiring a repair, and a fiber-optic ureteroscope is typically used 6 to 15 times before being returned to its maker [\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e, \u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eLegemate et al. [\u003cspan citationid=\"CR22\" class=\"CitationRef\"\u003e22\u003c/span\u003e] reported that digital re-fURSs had more extended durability (mean: 27; 20\u0026ndash;56) compared to fiber-optic fURSs (mean: 24; 10\u0026ndash;37), but the average durability of re-fURSs ranged from 3 to 11 cases [\u003cspan citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e, \u003cspan additionalcitationids=\"CR24\" citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e]. Another study concluded that not only are new fURSs\u003c/p\u003e \u003cp\u003emore resistant to malfunction (mean: 44) than refurbished devices, but the new re-furs last longer if they are maintained and repaired by the original maker (mean: 11.1) than by outside contractors (mean: 6.9) [\u003cspan citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e].\u003c/p\u003e \u003cp\u003ePrevious studies have tested the first generation of su-fURSs, but suboptimal surgical effects prevent their inclusion into daily practice [\u003cspan additionalcitationids=\"CR27\" citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e]. However, newer su-fURS provide similar clinical efficacy and maneuverability to reusable scopes and are now part of routine daily practice in urology [\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e, \u003cspan additionalcitationids=\"CR30 CR31 CR32 CR33\" citationid=\"CR29\" class=\"CitationRef\"\u003e29\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e]. Since su-fURSs don't need to be repaired, maintained, or sterilized, and the stock is managed by a hospital's pharmacy, one of their key benefits is accessibility and availability [\u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e, \u003cspan citationid=\"CR35\" class=\"CitationRef\"\u003e35\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eDespite adherence to the decontamination and sterilization processes of reusable ureteroscopes, risks of infection and cross-contamination exist. Ofstead et al. analyzed 16 re-fURS procedures in two different centers, finding that despite disinfection procedures, all the re-fURSs had visible damage and were contaminated with hemoglobin, protein, or microbial growth. There is no such risk with su-fURSs [\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eVarious studies have reported on the incidence rate of re-fURS breakage that occurs during storage or processing, finding that 7.7\u0026ndash;22% of the time, re-fURSs are damaged even in the hands of qualified staff [\u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e, \u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e, \u003cspan citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e, \u003cspan citationid=\"CR29\" class=\"CitationRef\"\u003e29\u003c/span\u003e]. Abraham et al. studied two identical fiber-optic re-fURSs that undergo sterilization through different sterilization processes. The first ureteroscope, sterilized with the Steris system, had 297 broken fibers, a 12-mm tear on its shaft, and a 37% loss in resolution after 100 sterilization cycles, according to the authors. Ten damaged fibers were found in the second re-fURS, which had been Cidex sterilized [\u003cspan citationid=\"CR36\" class=\"CitationRef\"\u003e36\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn our hospital, re-fURS re-sterilization involves three hours of labor and three paramedical personnel, while su-fURSs are stored in a sterile package in the operating room. The su-fURS are delivered to a burning device after each treatment.\u003c/p\u003e \u003cp\u003eThe price of buying, repairing, and sterilizing the scope must be factored into the total cost of re- fURSs. A modern re-fURS (Flex-X, Karl Storz, Germany) costs USD 13,611, according to a recent study [\u003cspan citationid=\"CR37\" class=\"CitationRef\"\u003e37\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn a recent Australian study, the digital Olympus URF-V was purchased for USD 20,200 [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e]. The cost of reprocessing this device includes paying employees (nurses, technicians, etc.) and buying supplies for cleaning, sterilization, packaging, and leakage testing. Recent cost analyses indicated that the cost of reprocessing ranged from USD 19.90 to USD 108.00 per case if the price of purchasing a STERRAD machine (a system that uses low-temperature hydrogen peroxide gas plasma technology to sterilize) is not taken into account [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e, \u003cspan additionalcitationids=\"CR38\" citationid=\"CR37\" class=\"CitationRef\"\u003e37\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR39\" class=\"CitationRef\"\u003e39\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn the present study, the average cost for re-FURS was approximately SAR 3,668 (USD 975) per case, and the price for su-fURS was approximately SAR 1,650 (USD 438) per case, that did not change from 2022 till end of 2024. Tagushi et al. reported a USD 3.65 recycling cost per re-fURS of the type used in their study [\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eThe purchase cost of a su-fURS is always a concerning issue. The business agreement between the manufacturer and the hospital has the most significant impact. LithoVueTM [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e, \u003cspan citationid=\"CR33\" class=\"CitationRef\"\u003e33\u003c/span\u003e, \u003cspan citationid=\"CR41\" class=\"CitationRef\"\u003e41\u003c/span\u003e], PolyscopeTM [\u003cspan citationid=\"CR42\" class=\"CitationRef\"\u003e42\u003c/span\u003e], and SemiFlexTM [\u003cspan citationid=\"CR30\" class=\"CitationRef\"\u003e30\u003c/span\u003e] have reported purchase prices ranging from USD 1,300 to USD 3,180, USD 700, and USD 800, respectively. More su-fURSs will be well-spent as production technology develops, perhaps lowering final retail pricing. As more manufacturers vie for market share, sales prices could also drop (Sales prices may decrease as more manufacturers compete for market share).\u003c/p\u003e \u003cp\u003eMartin et al. conducted a cost-benefit analysis on all available fURSs to determine the cost of re- fURSs. They reported a cost of USD 848.10 per case and favored the purchase of re-fURSs when more than 99 procedures a year were being performed at a hospital, suggesting that re-fURSs are more cost-effective in high-volume institutions [\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e]. Similarly, Mager et al. conducted a cost- analysis study to evaluate the expenses of fURSs. The study reported that the cost of re-fURS ranged between USD 436 and USD 708 per case. When the initial purchasing costs were added, the total cost increased to \u003cspan\u003e$\u003c/span\u003e1,212\u0026ndash;USD 1,743 per case. Based on data and studies, LithoVueTM procedures range in price from USD 1,300 (market pricing) to USD 3,180 (manufacturer's recommended wholesale price) per case. Mager et al. discovered in a prediction model that the routine use of su-fURSs would be more costly than the routine usage of re-fURSs after executing 61 to 118 examples [\u003cspan citationid=\"CR38\" class=\"CitationRef\"\u003e38\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn a German case series, Ozimek et al. reported 321 cases of kidney stone treatment and 102 diagnostic fURS surgeries. On average, 14.4 incidents resulted in scope damage, and all operations cost a total of USD 261,332. The calculated average cost per fURS procedure was USD 617.40. Ozimek et al. concluded that the use of re-fURSs was cost-effective when compared to the use of su-fURSs since the price of a LithoVueTM device was USD 1,227.50 [\u003cspan citationid=\"CR44\" class=\"CitationRef\"\u003e44\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eAccording to Hennessey et al., the mean cost per case for seven new digital re-fURSs utilized over 30 months was USD 533 (USD 276-USD 904), and the overall repair cost for these devices was USD 124,800. The increasing cost of 28 cases using re-fURSs was USD 38,360. For a su- fURS (LithoVueTM) that costs USD 1,918, the total cost would be USD 55,239 for the same 28 cases; thus, the re-fURSs would be more economical. Conversely, if the cost of su-fURSs were USD 920, then the cost for 28 cases would be USD 26,850, which would be a considerable economic, saving [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e].\u003c/p\u003e \u003cdiv id=\"Sec8\" class=\"Section2\"\u003e \u003ch2\u003eStudy limitation\u003c/h2\u003e \u003cp\u003eThe present study has some limitation including, the expense of maintaining room sterilization was not considered in the current analysis, which would have increased the price of processing re-fURSs. Another limitation of this study is that the waste processing of su-fURSs was not included in the cost analysis. Additionally, post operative possible infection and its treatment cost that may include hospital readmission were not evaluated in the study.\u003c/p\u003e \u003c/div\u003e"},{"header":"Conclusions","content":"\u003cp\u003eSeveral factors affect the cost analysis of su-fURSs compared to re-fURSs, such as the number and type of procedures and equipment cost. When considering the cost of sterilization and the time spent in cleaning, su-fURS may be more cost-effective than re-fURS in secondary hospitals with an average flow rate of patients. Moreover, su-fURS may be more reliable than re-fURS regarding wear and tear. Finally, it is essential to consider all these factors when determining which scope is most cost-effective for a particular procedure.\u003c/p\u003e"},{"header":"Abbreviations","content":"\u003cp\u003efURS: flexible ureteroscope\u003c/p\u003e\n\u003cp\u003eSAR:\u0026nbsp;Saudi\u0026nbsp;Arabian\u0026nbsp;Riyal USD: United States Dollar\u003c/p\u003e\n\u003cp\u003esu-fURS: single-use flexible ureteroscope re-fURS: reusable flexible ureteroscope\u003c/p\u003e"},{"header":"Declarations","content":"\u003cp\u003eEthics\u0026nbsp;approval\u0026nbsp;:\u0026nbsp;IRB\u0026nbsp;approval\u0026nbsp;number\u0026nbsp;(0535301122-\u0026nbsp;Security\u0026nbsp;Force\u0026nbsp;Hospital\u0026nbsp;/\u0026nbsp;Makkah.\u0026nbsp;Saudia\u0026nbsp;Arabia) Consent for publication: Consent for publication was obtained\u003c/p\u003e\n\u003cp\u003eFunding: None\u003c/p\u003e\n\u003cp\u003eConflict of interrest :\u0026nbsp;\u0026nbsp;there are no financial or institutional conflicts of interest influencing the present study.\u003c/p\u003e\u003ch2\u003eAuthor Contribution\u003c/h2\u003e\u003cp\u003eA. I. A.: Idea owner, helped in writing the manuscript, data collectionA. A: helped in writing manuscriptS. A. K.: writing the manuscript and data collectionA. T.: data collectionA. A.\u0026nbsp;: Data collectionW. A.: Data collectionA. M.: writing manuscriptA. B: data collectionS. A.: data collectionA.H.: writing manuscript, data collection\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\n\u003cli\u003eT\u0026uuml;rk, , et al., \u003cem\u003eEAU guidelines on interventional treatment for urolithiasis. \u003c/em\u003eEuropean urology, 2016. \u003cstrong\u003e69\u003c/strong\u003e(3): p. 475-482.\u003c/li\u003e\n\u003cli\u003eRoupr\u0026ecirc;t, , et al., \u003cem\u003eEuropean Association of Urology guidelines on upper urinary tract urothelial carcinoma: 2020 update. \u003c/em\u003eEuropean urology, 2021. \u003cstrong\u003e79\u003c/strong\u003e(1): p. 62-79.\u003c/li\u003e\n\u003cli\u003eSeisen, T., et al., \u003cem\u003eOncologic outcomes of kidney-sparing surgery versus radical\u0026nbsp;\u003c/em\u003e\u003cem\u003enephroureterectomy for upper tract urothelial carcinoma: a systematic review by the EAU non- muscle invasive bladder cancer guidelines panel. \u003c/em\u003eEuropean urology, 2016. \u003cstrong\u003e70\u003c/strong\u003e(6): p. 1052-1068.\u003c/li\u003e\n\u003cli\u003eSemins, J., et al., \u003cem\u003eUreteroscope cleaning and sterilization by the urology operating room team: the effect on repair costs. \u003c/em\u003eJournal of endourology, 2009. \u003cstrong\u003e23\u003c/strong\u003e(6): p. 903-905.\u003c/li\u003e\n\u003cli\u003eOfstead, L., et al., \u003cem\u003eThe effectiveness of sterilization for flexible ureteroscopes: A real-world study. \u003c/em\u003eAmerican journal of infection control, 2017. \u003cstrong\u003e45\u003c/strong\u003e(8): p. 888-895.\u003c/li\u003e\n\u003cli\u003eSabnis, B., A. Bhattu, and V. Mohankumar, \u003cem\u003eSterilization of endoscopic instruments. \u003c/em\u003eCurrent Opinion in Urology, 2014. \u003cstrong\u003e24\u003c/strong\u003e(2): p. 195-202.\u003c/li\u003e\n\u003cli\u003eKaraolides, , et al., \u003cem\u003eImproving the durability of digital flexible ureteroscopes. \u003c/em\u003eUrology, 2013.\u003cstrong\u003e81\u003c/strong\u003e(4): p. 717-722.\u003c/li\u003e\n\u003cli\u003eCarey, I., et al., \u003cem\u003eFrequency of ureteroscope damage seen at a tertiary care center. \u003c/em\u003eThe Journal of urology, 2006. \u003cstrong\u003e176\u003c/strong\u003e(2): p. 607-610.\u003c/li\u003e\n\u003cli\u003eCarey, R.I., C.J. Martin, and J.R. Knego, \u003cem\u003eProspective evaluation of refurbished flexible ureteroscope durability seen in a large public tertiary care center with multiple \u003c/em\u003eUrology, 2014. \u003cstrong\u003e84\u003c/strong\u003e(1): p. 42-45.\u003c/li\u003e\n\u003cli\u003eLegemate, J.D., et al., \u003cem\u003eDurability of flexible ureteroscopes: a prospective evaluation of longevity, the factors that affect it, and damage \u003c/em\u003eEuropean urology focus, 2019. \u003cstrong\u003e5\u003c/strong\u003e(6): p. 1105- 1111.\u003c/li\u003e\n\u003cli\u003eVentimiglia, , B.K. Somani, and O. Traxer, \u003cem\u003eFlexible ureteroscopy: reuse? Or is single use the new direction? \u003c/em\u003eCurrent Opinion in Urology, 2020. \u003cstrong\u003e30\u003c/strong\u003e(2): p. 113-119.\u003c/li\u003e\n\u003cli\u003eSchlager, , et al., \u003cem\u003ePerformance of single-use flexorvue vs reusable boavision ureteroscope for\u0026nbsp;\u003c/em\u003e\u003cem\u003evisualization of calices and stone extraction in an artificial kidney model. \u003c/em\u003eJournal of endourology, 2017. \u003cstrong\u003e31\u003c/strong\u003e(11): p. 1139-1144.\u003c/li\u003e\n\u003cli\u003eProietti, S., et al., \u003cem\u003eComparison of new single-use digital flexible ureteroscope versus nondisposable fiber optic and digital ureteroscope in a cadaveric \u003c/em\u003eJournal of endourology, 2016. \u003cstrong\u003e30\u003c/strong\u003e(6): p. 655-659.\u003c/li\u003e\n\u003cli\u003eVentimiglia, , et al., \u003cem\u003eCost comparison of single-use versus reusable flexible ureteroscope: A systematic review. \u003c/em\u003eTurkish journal of urology, 2020. \u003cstrong\u003e46\u003c/strong\u003e(Suppl 1): p. S40.\u003c/li\u003e\n\u003cli\u003eHennessey, B., et al., \u003cem\u003eSingle-use disposable digital flexible ureteroscopes: an ex vivo assessment and cost analysis. \u003c/em\u003eBJU international, 2018. \u003cstrong\u003e121\u003c/strong\u003e: p. 55-61.\u003c/li\u003e\n\u003cli\u003eAssimos, , et al., \u003cem\u003eSurgical management of stones: American urological\u0026nbsp;\u003c/em\u003e\u003cem\u003eassociation/endourological society guideline, PART I. \u003c/em\u003eThe Journal of urology, 2016. \u003cstrong\u003e196\u003c/strong\u003e(4): p. 1153-1160.\u003c/li\u003e\n\u003cli\u003eSomani, K., et al., \u003cem\u003eOutcomes of flexible ureterorenoscopy and laser fragmentation for renal stones: comparison between digital and conventional ureteroscope. \u003c/em\u003eUrology, 2013. \u003cstrong\u003e82\u003c/strong\u003e(5): p. 1017-1019.\u003c/li\u003e\n\u003cli\u003eEmiliani, and O. Traxer, \u003cem\u003eSingle use and disposable flexible ureteroscopes. \u003c/em\u003eCurrent opinion in urology, 2017. \u003cstrong\u003e27\u003c/strong\u003e(2): p. 176-181.\u003c/li\u003e\n\u003cli\u003eKnudsen, , et al., \u003cem\u003eDurability of the next-generation flexible fiberoptic ureteroscopes: a\u0026nbsp;\u003c/em\u003e\u003cem\u003erandomized prospective multi-institutional clinical trial. \u003c/em\u003eUrology, 2010. \u003cstrong\u003e75\u003c/strong\u003e(3): p. 534-538.\u003c/li\u003e\n\u003cli\u003eMonga, , et al., \u003cem\u003edurability of flexible ureteroscopes: a randomized, prospective study. \u003c/em\u003eThe Journal of urology, 2006. \u003cstrong\u003e176\u003c/strong\u003e(1): p. 137-141.\u003c/li\u003e\n\u003cli\u003eAFANE, S., et al., \u003cem\u003eFlexible ureteroscopes: a single center evaluation of the durability and\u0026nbsp;\u003c/em\u003e\u003cem\u003efunction of the new endoscopes smaller than 9Fr. \u003c/em\u003eThe Journal of urology, 2000. \u003cstrong\u003e164\u003c/strong\u003e(4): p. 1164- 1168.\u003c/li\u003e\n\u003cli\u003eLegemate, D., et al., \u003cem\u003ePre-use ureteroscope contamination after high level disinfection:\u0026nbsp;\u003c/em\u003e\u003cem\u003ereprocessing effectiveness and the relation with cumulative ureteroscope use. \u003c/em\u003eThe Journal of Urology, 2019. \u003cstrong\u003e201\u003c/strong\u003e(6): p. 1144-1151.\u003c/li\u003e\n\u003cli\u003eBinbay, , et al., \u003cem\u003eIs there a difference in outcomes between digital and fiberoptic flexible ureterorenoscopy procedures? \u003c/em\u003eJournal of endourology, 2010. \u003cstrong\u003e24\u003c/strong\u003e(12): p. 1929-1934.\u003c/li\u003e\n\u003cli\u003eCollins, , F. Keeley, and A. Timoney, \u003cem\u003eCost analysis of flexible ureterorenoscopy. \u003c/em\u003eBJU international, 2004. \u003cstrong\u003e93\u003c/strong\u003e(7): p. 1023-1026.\u003c/li\u003e\n\u003cli\u003eUser, M., et al., \u003cem\u003ePerformance and durability of leading flexible ureteroscopes. \u003c/em\u003eJournal of endourology, 2004. \u003cstrong\u003e18\u003c/strong\u003e(8): p. 735-738.\u003c/li\u003e\n\u003cli\u003eDing, , et al., \u003cem\u003eComparing the efficacy of a multimodular flexible ureteroscope with its\u0026nbsp;\u003c/em\u003e\u003cem\u003econventional counterpart in the management of renal stones. \u003c/em\u003eUrology, 2015. \u003cstrong\u003e86\u003c/strong\u003e(2): p. 224-229.\u003c/li\u003e\n\u003cli\u003eGu, S.-P., et al., \u003cem\u003eClinical effectiveness of the PolyScope\u0026trade; endoscope system combined with\u0026nbsp;\u003c/em\u003e\u003cem\u003eholmium laser lithotripsy in the treatment of upper urinary calculi with a diameter of less than 2 cm. \u003c/em\u003eExperimental and therapeutic medicine, 2013. \u003cstrong\u003e6\u003c/strong\u003e(2): p. 591-595.\u003c/li\u003e\n\u003cli\u003eBansal, , et al., \u003cem\u003ePolyscope: a new era in flexible ureterorenoscopy. \u003c/em\u003eJournal of endourology, 2011. \u003cstrong\u003e25\u003c/strong\u003e(2): p. 317-321.\u003c/li\u003e\n\u003cli\u003eUsawachintachit, , et al., \u003cem\u003eA prospective case\u0026ndash;control study comparing LithoVue, a single-use, flexible disposable ureteroscope, with flexible, reusable fiber-optic ureteroscopes. \u003c/em\u003eJournal of endourology, 2017. \u003cstrong\u003e31\u003c/strong\u003e(5): p. 468-475.\u003c/li\u003e\n\u003cli\u003eBoylu, , et al., \u003cem\u003eIn vitro comparison of a disposable flexible ureteroscope and conventional flexible ureteroscopes. \u003c/em\u003eThe Journal of urology, 2009. \u003cstrong\u003e182\u003c/strong\u003e(5): p. 2347-2351.\u003c/li\u003e\n\u003cli\u003eSalvad\u0026oacute;, A., et al., \u003cem\u003eClinical Comparison between Three Single-Use Flexible Ureteroscope Models: A Real-World Experience. \u003c/em\u003eUrologia Internationalis, 2022. \u003cstrong\u003e106\u003c/strong\u003e(12): p. 1220-1225.\u003c/li\u003e\n\u003cli\u003eDale, , et al., \u003cem\u003eEvaluation of a novel single-use flexible ureteroscope. \u003c/em\u003eJournal of endourology, 2021. \u003cstrong\u003e35\u003c/strong\u003e(6): p. 903-907.\u003c/li\u003e\n\u003cli\u003eGhodoussipour, , et al., \u003cem\u003eMp50-08 Limitations of the lithovue single use digital flexible ureteroscope. \u003c/em\u003eThe Journal of Urology, 2017. \u003cstrong\u003e197\u003c/strong\u003e(4S): p. e686-e687.\u003c/li\u003e\n\u003cli\u003eTom, R., et al., \u003cem\u003eNext-generation single-use ureteroscopes: an in vitro comparison. \u003c/em\u003eJournal of endourology, 2017. \u003cstrong\u003e31\u003c/strong\u003e(12): p. 1301-1306.\u003c/li\u003e\n\u003cli\u003eDavis, , et al., \u003cem\u003eSingle-use flexible ureteropyeloscopy: a systematic review. \u003c/em\u003eWorld Journal of Urology, 2018. \u003cstrong\u003e36\u003c/strong\u003e: p. 529-536.\u003c/li\u003e\n\u003cli\u003eMarchini, S., et al., \u003cem\u003eA comprehensive literature-based equation to compare cost-effectiveness of a flexible ureteroscopy program with single-use versus reusable devices. \u003c/em\u003eInternational braz j urol, 2019. \u003cstrong\u003e45\u003c/strong\u003e: p. 658-670.\u003c/li\u003e\n\u003cli\u003eGurbuz, , et al., \u003cem\u003eThe cost analysis of flexible ureteroscopic lithotripsy in 302 cases. \u003c/em\u003eUrolithiasis, 2014. \u003cstrong\u003e42\u003c/strong\u003e: p. 155-158.\u003c/li\u003e\n\u003cli\u003eMager, R., et al., \u003cem\u003eClinical outcomes and costs of reusable and single-use flexible\u0026nbsp;\u003c/em\u003e\u003cem\u003eureterorenoscopes: a prospective cohort study. \u003c/em\u003eUrolithiasis, 2018. \u003cstrong\u003e46\u003c/strong\u003e: p. 587-593.\u003c/li\u003e\n\u003cli\u003eIsaacson, , et al., \u003cem\u003eDefining the costs of reusable flexible ureteroscope reprocessing using time- driven activity-based costing. \u003c/em\u003eJournal of endourology, 2017. \u003cstrong\u003e31\u003c/strong\u003e(10): p. 1026-1031.\u003c/li\u003e\n\u003cli\u003eTaguchi, , et al., \u003cem\u003eMicro-costing analysis demonstrates comparable costs for LithoVue compared to reusable flexible fiberoptic ureteroscopes. \u003c/em\u003eJournal of endourology, 2018. \u003cstrong\u003e32\u003c/strong\u003e(4): p. 267-273.\u003c/li\u003e\n\u003cli\u003eStern, M., J. Yiee, and S. Park, \u003cem\u003eSafety and efficacy of ureteral access sheaths. \u003c/em\u003eJournal of endourology, 2007. \u003cstrong\u003e21\u003c/strong\u003e(2): p. 119-123.\u003c/li\u003e\n\u003cli\u003eSiu, J.-Y., et al., \u003cem\u003eThe Cost-Effectiveness of Treatment Modalities for Ureteral Stones: A National Comprehensive Study. \u003c/em\u003eINQUIRY: The Journal of Health Care Organization, Provision, and Financing, 2016. \u003cstrong\u003e53\u003c/strong\u003e: p. 0046958016669015.\u003c/li\u003e\n\u003cli\u003eMartin, J., et al., \u003cem\u003eThe economic implications of a reusable flexible digital ureteroscope: a cost- benefit analysis. \u003c/em\u003eThe Journal of urology, 2017. \u003cstrong\u003e197\u003c/strong\u003e(3): p. 730-735.\u003c/li\u003e\n\u003cli\u003eOzimek, , et al., \u003cem\u003eRetrospective cost analysis of a single-center reusable flexible\u0026nbsp;\u003c/em\u003e\u003cem\u003eureterorenoscopy program: a comparative cost simulation of disposable fURS as an alternative.\u0026nbsp;\u003c/em\u003eJournal of Endourology, 2017. \u003cstrong\u003e31\u003c/strong\u003e(12): p. 1226-1230.\u003c/li\u003e\n\u003c/ol\u003e"},{"header":"Tables","content":"\u003cp\u003eTable 1 and 2 are available in the Supplementary Files section.\u003c/p\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"[email protected]","identity":"african-journal-of-urology","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"afju","sideBox":"Learn more about [African Journal of Urology](http://link.springer.com/journal/12293)","snPcode":"12301","submissionUrl":"https://submission.springernature.com/new-submission/12301/3","title":"African Journal of Urology","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Springer Hybrid","inReviewEnabled":true,"inReviewRevisionsEnabled":false},"keywords":"Cost, flexible, ureteroscopy","lastPublishedDoi":"10.21203/rs.3.rs-5069441/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-5069441/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003eBackground: The goal of our study is to analyze the possible economic benefits of single-use flexible ureteroscopes (su-fURSs) and compare their cost effectiveness with that of reusable flexible ureteroscopes (re-fURSs) in secondary hospitals with an average patient flow rate.\u003c/p\u003e\n\u003cp\u003eMethodes: The present study is a single-center, retrospective study conducted at Security Force Hospital, Makkah, Saudia Arabia. The study included data from all flexible ureteroscopy procedures performed in the urology department of the hospitals between June 2021 and December 2023. Karl Storz FLEX-X2S fiber-optic ureteroscopes were used for the procedures involving re-fURS, and the cost assessment took into account the initial cost of purchasing, the cost of reprocessing, and the cost of replacement split by the number of cases. This cost was compared with the costs of using WiScope (OTU Medical Inc.), a digital su-fURS.\u003c/p\u003e\n\u003cp\u003eResults: Out of the total cases included in the study, 180 utilized su-fURSs, and 59 utilized re- fURSs with one repair exchange done during the observed study period. The average cost of using a re-fURS was approximately SAR 3,668 (USD 975) per case, while the cost of using a su- fURS was approximately SAR 1,650 (USD 438) per case.\u003c/p\u003e\n\u003cp\u003eConclusions: Su-fURS is a more cost-effective procedure than re-fURS performed in secondary hospitals with an average patient flow. Su-fURS may be more reliable than re-fURS regarding wear and tear. It is essential to consider different factors such as the cost of sterilization and the time spent in cleaning when determining which scope is most cost-effective for a particular procedure.\u003c/p\u003e","manuscriptTitle":"Economic evaluation of a Single use Flexible Digital Ureteroscope : Cost Analysis","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2025-05-28 07:52:19","doi":"10.21203/rs.3.rs-5069441/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"decision","content":"Accepted","date":"2025-06-03T01:00:13+00:00","index":"","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2025-05-26T19:59:31+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"196009172483494213902441477368211342635","date":"2025-05-26T19:49:34+00:00","index":"hide","fulltext":""},{"type":"reviewersInvited","content":"","date":"2025-05-26T19:04:35+00:00","index":"","fulltext":""},{"type":"checksComplete","content":"","date":"2025-05-26T00:41:12+00:00","index":"","fulltext":""},{"type":"submitted","content":"African Journal of Urology","date":"2025-05-25T16:55:53+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"[email protected]","identity":"african-journal-of-urology","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"afju","sideBox":"Learn more about [African Journal of Urology](http://link.springer.com/journal/12293)","snPcode":"12301","submissionUrl":"https://submission.springernature.com/new-submission/12301/3","title":"African Journal of Urology","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Springer Hybrid","inReviewEnabled":true,"inReviewRevisionsEnabled":false}}],"origin":"","ownerIdentity":"fb2b97f5-4f82-4577-94b4-2d299efc326c","owner":[],"postedDate":"May 28th, 2025","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[],"tags":[],"updatedAt":"2025-06-23T16:03:15+00:00","versionOfRecord":{"articleIdentity":"rs-5069441","link":"https://doi.org/10.1186/s12301-025-00510-0","journal":{"identity":"african-journal-of-urology","isVorOnly":false,"title":"African Journal of Urology"},"publishedOn":"2025-06-18 15:57:14","publishedOnDateReadable":"June 18th, 2025"},"versionCreatedAt":"2025-05-28 07:52:19","video":"","vorDoi":"10.1186/s12301-025-00510-0","vorDoiUrl":"https://doi.org/10.1186/s12301-025-00510-0","workflowStages":[]},"version":"v1","identity":"rs-5069441","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-5069441","identity":"rs-5069441","version":["v1"]},"buildId":"8U1c8b4HqxoKbykW_rLl7","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00