Reflected Inline Detection in Epi Oblique Plane Microscopy

preprint OA: closed
📄 Open PDF Full text JSON View at publisher
Full text 1,666 characters · extracted from oa-doi-fallback · click to expand
Abstract Epi oblique illumination selective plane microscopy (OPM) facilitates open-top, straightforward sample mounting, enabling high-resolution and high-speed imaging without perturbing biological specimens. However, current OPM systems typically require three separate microscopes equipped with specialized objectives. This configuration leads to complex and costly setups, significant long-term drift during imaging, reduced numerical aperture, and limited flexibility in adjusting the illumination tilt angle. We introduce Reflected Inline Detection in Epi-Oblique Plane Microscopy (RIDE-OPM), a novel, simplified, and cost-effective design that removes the necessity for a separate inline tertiary microscope and specialized objectives. Our tilt-angle-independent approach leverages the maximum NA of standard objectives, ensuring optimal illumination across the entire field of view without compromising imaging speed or quality, while significantly reducing long-term system drift. The compact and stable RIDE-OPM platform demonstrates robust, unsupervised long-term imaging capabilities. We validated this performance by successfully imaging various biological specimens, including C. elegans, Drosophila fly brain, human and mouse epithelial cells, and live E. coli, underscoring its suitability for advanced long-term biological imaging applications. Competing Interest Statement T.C. and M.N.H.P. have filed a patent application (United States Patent and Trademark Office application) for the RIDE-OPM microscope mentioned here. The remaining authors declare no competing interests. Footnotes Several sections to clarify, All figures, Supplemental files

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc