Full text
30,482 characters
· extracted from
preprint-html
· click to expand
Multi-species cryoEM calibration and workflow verification standard | bioRxiv /* */ /* */ <!-- <!-- /*! * yepnope1.5.4 * (c) WTFPL, GPLv2 */ (function(a,b,c){function d(a){return"[object Function]"==o.call(a)}function e(a){return"string"==typeof a}function f(){}function g(a){return!a||"loaded"==a||"complete"==a||"uninitialized"==a}function h(){var a=p.shift();q=1,a?a.t?m(function(){("c"==a.t?B.injectCss:B.injectJs)(a.s,0,a.a,a.x,a.e,1)},0):(a(),h()):q=0}function i(a,c,d,e,f,i,j){function k(b){if(!o&&g(l.readyState)&&(u.r=o=1,!q&&h(),l.onload=l.onreadystatechange=null,b)){"img"!=a&&m(function(){t.removeChild(l)},50);for(var d in y[c])y[c].hasOwnProperty(d)&&y[c][d].onload()}}var j=j||B.errorTimeout,l=b.createElement(a),o=0,r=0,u={t:d,s:c,e:f,a:i,x:j};1===y[c]&&(r=1,y[c]=[]),"object"==a?l.data=c:(l.src=c,l.type=a),l.width=l.height="0",l.onerror=l.onload=l.onreadystatechange=function(){k.call(this,r)},p.splice(e,0,u),"img"!=a&&(r||2===y[c]?(t.insertBefore(l,s?null:n),m(k,j)):y[c].push(l))}function j(a,b,c,d,f){return q=0,b=b||"j",e(a)?i("c"==b?v:u,a,b,this.i++,c,d,f):(p.splice(this.i++,0,a),1==p.length&&h()),this}function k(){var a=B;return a.loader={load:j,i:0},a}var l=b.documentElement,m=a.setTimeout,n=b.getElementsByTagName("script")[0],o={}.toString,p=[],q=0,r="MozAppearance"in l.style,s=r&&!!b.createRange().compareNode,t=s?l:n.parentNode,l=a.opera&&"[object Opera]"==o.call(a.opera),l=!!b.attachEvent&&!l,u=r?"object":l?"script":"img",v=l?"script":u,w=Array.isArray||function(a){return"[object Array]"==o.call(a)},x=[],y={},z={timeout:function(a,b){return b.length&&(a.timeout=b[0]),a}},A,B;B=function(a){function b(a){var a=a.split("!"),b=x.length,c=a.pop(),d=a.length,c={url:c,origUrl:c,prefixes:a},e,f,g;for(f=0;f<d;f++)g=a[f].split("="),(e=z[g.shift()])&&(c=e(c,g));for(f=0;f<b;f++)c=x[f](c);return c}function g(a,e,f,g,h){var i=b(a),j=i.autoCallback;i.url.split(".").pop().split("?").shift(),i.bypass||(e&&(e=d(e)?e:e[a]||e[g]||e[a.split("/").pop().split("?")[0]]),i.instead?i.instead(a,e,f,g,h):(y[i.url]?i.noexec=!0:y[i.url]=1,f.load(i.url,i.forceCSS||!i.forceJS&&"css"==i.url.split(".").pop().split("?").shift()?"c":c,i.noexec,i.attrs,i.timeout),(d(e)||d(j))&&f.load(function(){k(),e&&e(i.origUrl,h,g),j&&j(i.origUrl,h,g),y[i.url]=2})))}function h(a,b){function c(a,c){if(a){if(e(a))c||(j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}),g(a,j,b,0,h);else if(Object(a)===a)for(n in m=function(){var b=0,c;for(c in a)a.hasOwnProperty(c)&&b++;return b}(),a)a.hasOwnProperty(n)&&(!c&&!--m&&(d(j)?j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}:j[n]=function(a){return function(){var b=[].slice.call(arguments);a&&a.apply(this,b),l()}}(k[n])),g(a[n],j,b,n,h))}else!c&&l()}var h=!!a.test,i=a.load||a.both,j=a.callback||f,k=j,l=a.complete||f,m,n;c(h?a.yep:a.nope,!!i),i&&c(i)}var i,j,l=this.yepnope.loader;if(e(a))g(a,0,l,0);else if(w(a))for(i=0;i (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0];var j=d.createElement(s);var dl=l!='dataLayer'?'&l='+l:'';j.src='//www.googletagmanager.com/gtm.js?id='+i+dl;j.type='text/javascript';j.async=true;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-M677548'); Skip to main content Home About Submit ALERTS / RSS Search for this keyword Advanced Search New Results Multi-species cryoEM calibration and workflow verification standard View ORCID Profile Daija Bobe , View ORCID Profile Mykhailo Kopylov , View ORCID Profile Jessalyn Miller , View ORCID Profile Aaron P. Owji , View ORCID Profile Edward T. Eng doi: https://doi.org/10.1101/2024.08.05.606612 Daija Bobe 1 Simons Electron Microscopy Center, New York Structural Biology Center , New York, NY 10027, USA Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Daija Bobe Mykhailo Kopylov 1 Simons Electron Microscopy Center, New York Structural Biology Center , New York, NY 10027, USA Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Mykhailo Kopylov Jessalyn Miller 1 Simons Electron Microscopy Center, New York Structural Biology Center , New York, NY 10027, USA Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Jessalyn Miller Aaron P. Owji 1 Simons Electron Microscopy Center, New York Structural Biology Center , New York, NY 10027, USA Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Aaron P. Owji Edward T. Eng 1 Simons Electron Microscopy Center, New York Structural Biology Center , New York, NY 10027, USA Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Edward T. Eng For correspondence: eeng{at}nysbc.org Abstract Full Text Info/History Metrics Supplementary material Data/Code Preview PDF Abstract Cryogenic electron microscopy (cryoEM) is a rapidly growing structural biology modality that has been successful in revealing molecular details of biological systems. However, unlike established biophysical and analytical techniques with calibration standards, cryoEM has lacked comprehensive biological test samples. We introduce a cryoEM calibration sample that is a mixture of compatible macromolecules that can be used not only for resolution optimization but also provides multiple reference points for evaluating instrument performance, data quality, and image processing workflows in a single experiment. This combined test specimen provides researchers a reference point for validating their cryoEM pipeline, benchmarking their methodologies, and testing new algorithms. Introduction Cryogenic electron microscopy (cryoEM) has grown increasingly popular in structural biology as the quality and reliability of cryo-transmission electron microscopes have improved. However, due to the complex nature of the instrumentation, each microscope in operation is unique. Microscope builds can feature different gun sources, accelerating voltages, condenser systems, aberration correctors and filters, and camera types. Each microscope is affected by its local environment such as temperature, humidity, vibrations and electromagnetic fields, all of which influence data quality 1 , 2 . To ensure optimal performance, cryoEM practitioners rely on workflow validation tests using an analytical benchmark standard 3 – 5 . Current requirements for cryoEM benchmarking standard are: Accessible : can either be commercially purchased or has straightforward sample preparation with low maintenance requirements. Stable : can be stored for prolonged periods of time without compromising structural integrity. Homogeneous : minimal conformational and compositional heterogeneity. Reproducible : grid preparation can be standardized reducing grid-to-grid variability. Common benchmarking samples, including ribosomes, tobacco mosaic virus, beta-galactosidase, aldolase and apoferritin, meet the above criteria and have proven useful for resolution optimization 3 , 6 – 8 . Despite its importance, maximizing resolution is not the only goal of the cryoEM workflow. The datasets acquired for benchmarking resolution can also be used to support other aspects of the cryoEM workflow such as pixel size calibration, neural network training, helical and single-particle processing, etc. Here, we introduce a dedicated cryoEM calibration standard called the “EM ladder”, which extends beyond resolution benchmarking. A key aspect of the EM ladder is its ability to be used reproducibly under a wide variety of experimental conditions and pixel sizes for calibration, commissioning, and certification of standard operating procedures. Similar to calibration standards for SDS-PAGE, size exclusion chromatography, and mass photometry, there is not a single calibration reagent, but a mixture of components to be compatible with the full experimental workflow. We have combined a mixture of four samples: apoferritin (ApoF - O symmetry, ∼486 kDa, 20 kDa monomer), beta-galactosidase (β-gal - D2 symmetry, ∼465 kDa, 116 kDa monomer), a virus-like particle (PP7 - I symmetry, ∼3.4 MDa, 28 kDa monomer), and tobacco mosaic virus (TMV - H symmetry ∼40 MDa, 18 kDa monomer). The main focus of this calibration standard is to provide a stable and well-characterized reference point that ensures that the full workflow of grid preparation, data collection, processing, and analysis is reliable. As cryoEM continues to evolve and be applied to new fields, this calibration standard broadens the scope where structural insights are not just high in resolution but also high in accuracy, enabling the full potential of structural biological research. Materials and Methods Samples The stock apoferritin (ferritin human H chain, ApoF) was purified in 50 mM Tris pH 7.5, 100 mM NaCl, and 0.5 mM TCEP by the Center on Membrane Protein Production and Analysis (COMPPÅ) at the New York Structural Biology Center. The original plasmid LF2422 contains ferritin human H chain cloned into pGEX2T with a TEV site instead of thrombin from the Protex facility at the University of Leicester, and gifted to NYSBC by Louise Fairall and Christos Savva. Thyroglobulin (ThG) was purchased from Sigma (Product Number T1001). The lyophilized powder (40 mg) was reconstituted in a storage buffer consisting of 20mM HEPES pH 7.4, 150 mM NaCl buffer. Beta-galactosidase (β-gal) was purchased from Sigma (Product Number G5635). The lyophilized β-gal (50 mg) was reconstituted in a storage buffer consisting of 50 mM Tris HCl, 10 mM MgCl2, 10 mM beta-mercaptoethanol at pH 7.3. PP7 VLPs were a gift from M.G. Finn’s group. PP7 WT sample was provided as a 1 mg/mL solution in 100 mM PBS pH 7.0 as previously described 9 . Tobacco Mosaic Virus (TMV) at a stock concentration of 34.85 mg/mL in TBS was a gift from Ruben Diaz-Avalos. For the final mix that was used for cryoEM imaging, each protein was diluted with 50 mM HEPES pH 7.5, 100 mM NaCl. This buffer was chosen for its compatibility with each protein. The final concentration for each protein prior to mixing was as follows: 0.16 mg/mL apoferritin, 0.10 mg/mL PP7, 1 mg/mL β-gal, 0.17 mg/mL TMV. To create the final mix, 2 μL of each protein was added together. The concentrations of each protein in the final mix were as follows: 0.04 mg/mL ApoF, 0.025 mg/mL PP7, 0.25 mg/mL β-gal, 0.0425 mg/mL TMV. The mix was aliquoted, snap frozen, and stored at –80C for later use. Negative stain grid preparation Continuous carbon grids made in-house were plasma cleaned with a hydrogen/oxygen mix for 30 s on a Gatan Solarus. Two 20 μL droplets of distilled water were added to parafilm followed by three 20 μL droplets of 2% uranyl formate. 3 μL of sample was applied to the continuous carbon grid for 45 s to 1 min. The grid was side blotted, then followed the sequence of dipping into a droplet carbon side down and side blotting for both water droplets and two uranyl formate droplets. The grid was held in the last uranyl formate droplet for 1 min before side blotting and back blotting to remove excess stain. CryoEM grid preparation 3 μL of freshly thawed protein from the final mix was applied to plasma-cleaned UltrAuFoil R1.2/1.3 300 mesh holey gold grids (Quantifoil® Micro Tools, Großlöbichau, Germany), blotted for 2.5 s after a 30 s wait time, and then plunge frozen in liquid ethane, cooled by liquid nitrogen, using the Vitrobot Mark III (FEI, Hillsboro, OR) at 75% relative humidity. Screening For screening a Thermo Fisher Scientific Tecnai 12 with a Gatan TVIPS F416 CMOS camera was operated at 120 kV with a 100 μm objective aperture. Images were collected at a pixel size of 2.46 Å using Leginon 10 at 800 ms per exposure with a dose of ∼50 e-/Å2 and at a nominal defocus range of 2–4 μm. Data acquisition For final data acquisition a Thermo Fisher Scientific Titan Krios G2 with a spherical aberration corrector and a post-column Gatan Image Filter (GIF) and Gatan K2 Summit was operated at 300 kV with a 70 μm C2 aperture and 100 μm objective aperture. Images were collected in counting mode with a 30 eV slit width and calibrated pixel size of 1.096 Å using Leginon 10 at a dose rate of 6.95 e−/Å 2 /s with a total exposure of 10 s, for an accumulated dose of 69.46 e−/Å 2 . A total of 3,996 images were collected at a nominal defocus range of 1.5–2.5 μm. Given data retention policies the original movies were not archived and the MotionCor2 with dose weighting 11 aligned summed images by the Appion 12 pre-processing pipeline were stored as JPEG for Appion image viewer functionality 13 . For this study, those images were converted back to 32-bit MRC files using EMAN2 14 for further processing in cryoSPARC 15 . Image Processing The 19jan04d dataset was manually curated and 1,862 out of the 3,996 images had three or more protein types. After conversion to 32-bit MRC, selected images were imported into cryoSPARC as micrographs for CTF estimation, particle picking and extraction, and subjected to 2D and 3D classification, initial model generation and refinement. Processing settings for the one-shot processing are reported in Table 1 with all non-default settings highlighted. Additional details and intermediate results of the processing of individual components are provided in supplemental information. View this table: View inline View popup Table 1. CryoSPARC processing parameters for one-shot parallel processing. Gray rows - processing common to all four species; blue rows - ApoF specific steps; red rows - β-gal specific steps; yellow rows - PP7 specific steps; green rows - TMV specific steps. Results and Discussion Four components were chosen for the EM ladder: ApoF, β-gal, PP7 and TMV. ApoF is an octahedral protein cage and a widely used specimen for characterization of the resolution limit of cryoEM microscopes. Mouse ApoF has yielded the highest available resolution from cryoEM single-particle analysis. Commercially available horse spleen ApoF can be used resulting in ∼2 Å reconstructions 8 , 16 . However, ApoF is notoriously difficult to reconstruct from poor-quality data acquired from thick ice, charge-coupled detectors (CCDs), or low-voltage microscopes 17 – 19 , so β-gal in this EM ladder mix serves as a low-symmetry (D2) standard. It is commercially available and has been used extensively as a high-resolution test specimen. Prior to vitrification, β-gal can be incubated with various ligands, such as PETG, for additional stability 6 . β-gal can be replaced in this mix with aldolase, conalbumin or any other low-symmetry small protein, although particle concentration and ratio of the mix may differ. PP7 VLPs are ∼22 nm icosahedral particles that can be reconstructed in a broad resolution range - from 30 Å to 2.5 Å. PP7 particles are twice the diameter of ApoF and can serve as an alternative for ApoF as a pixel size calibration standard. PP7 VLPs can be replaced with other large particles such as AAV, Q-beta, proteasome or GroEL. Finally, TMV has been used extensively as a resolution test specimen. It can be effectively used as another alternative for pixel size calibration and for processing as it provides a good starting point in learning helical processing. TMV can be replaced with similar helical viruses, microtubules or other helically-symmetric elongated constructs. 3,996 micrographs of the EM ladder were acquired, and each micrograph was manually selected for containing at least 3 species in the field of view, good ice and little to no gold included in the image. All four species can be easily identified in a micrograph - ApoF “donuts”, small spindle-shaped β-gal, large hexagons of PP7 VLPs and “train tracks” of TMV ( Figure 1A ). Processing these data also provides clear and easily interpretable results from particle picking, through 2D classification and initial model generation, to 3D refinement ( Figure 1B ). Despite the different sizes and symmetry types present in this dataset, initial processing can be done in only 22 cryoSPARC jobs following a one-shot processing strategy, where a single box size is used for all particles ( Table 1 , Figure S1). This results in sub-3 Å reconstructions for two species - the most abundant ApoF and helical TMV. Particle picking, box size, and classification and refinement strategies can be optimized from this point (Figure S2-S5). Final reconstructions for this multi-species dataset resulted in a GSFSC resolution of 2.47 Å for ApoF, 2.74 Å for β-gal, 3.37 Å for PP7 and 2.46 Å for TMV ( Figure 2 ). Download figure Open in new tab Figure 1. Multi-species dataset overview. A) An exemplar micrograph with four types of particles boxed out. B) Typical processing results: individual extracted particles, 2D class averages, x-y slice through the center of ab-initio reconstruction, 3D map visualized in ChimeraX. Download figure Open in new tab Figure 2. CryoEM reconstructions from multi-species dataset. A) Isosurface representations of (from left to right) : ApoF, β-gal, TMV, and PP7. B) PDB model fit to map in mesh of (from left to right) : ApoF 1FHA chain A: 14-42, β-gal 6X1Q chain A: 429-448, TMV 6R7M chain A: 107-136, and PP7 1DWN chain A: 96-121. C) Histogram and directional FSC plot with sphericity representation and transparent isosurface view (from left to right) : ApoF at a global resolution of 2.47 Å with 164,200 particles and sphericity of 0.985, β-gal at a global resolution of 2.74 Å with 37,617 particles and sphericity of 0.976, TMV at a global resolution of 2.46 Å with 12,038 particles and sphericity of 0.977, and PP7 at a global resolution of 3.37 Å with 1,803 particles and sphericity of 0.980. After negative stain screening of the initial mix, the concentration of ApoF was halved due to it being the dominant protein in the micrographs ( Figure 3 ). Each mix was subsequently changed based on the amount of each protein seen during screening. The decision to switch to cryo for screening was made after observation that a mix that had a good distribution of each protein in negative stain did not have the same distribution in cryo. During cryo screening, broken ends of thyroglobuin (ThG) were visible in the background of the micrographs. ThG requires detergent, such as CHAPS, to remain fully intact in cryo. For further mixes, ThG was switched to β-gal in order for all proteins in the mix to be fully reconstructed without adding detergent to the buffer. Download figure Open in new tab Figure 3. Representative images from trials of multi-protein mixtures. A through E: negative stain micrographs of mixes 1 through 5. F through I: cryo micrographs of mixes 6 through 9. A=mix 1, B=mix 2, C=mix 3, D=mix 4, E=mix 5, F=mix 6, G=mix 7, H=mix 8, I=mix 9. Exact mix compositions are shown in Table 2 . Although ApoF has become a widely used benchmarking standard for high resolution testing of all transmission electron microscopes 20 – 22 , it still presents a challenge when processing. Due to the similar size of β-gal and ApoF, having both present within a micrograph is useful to test several particle pickers for their ability to differentiate between the two species, while also being able to benchmark the microscope. In contrast to ApoF, VLPs are larger, simple to pick, and can be used for low resolution testing as well as calibrating pixel sizes. In addition to the single particle processing practice, including TMV in the mix presents the opportunity to learn or improve the ability to do helical processing. TMV has been widely studied, so knowing the pitch, rise and twist is helpful whether you are processing from scratch and needing to confirm parameters, or if you are just trying to learn the different steps involved in helical processing versus single particle processing. View this table: View inline View popup Download powerpoint Table 2. Protein composition mix trials with representative images in Figure 3 . Concentrations are in mg/ml. As new practitioners adopt cryoEM workflows in their research programs, they need guidelines to not only ensure that their pipelines are compatible with their experimental requirements but also to be confident that their instrumentation can yield reliable and accurate results. Within a single experiment using a cryoEM calibration standard, researchers can validate a particular imaging condition or generate training datasets that can be used for benchmarking and cryoEM education. Conclusions The introduction of dedicated cryoEM calibration standards extends far beyond benchmarking instrumentation by providing baseline control experiments for researchers to standardize their entire workflow for use in biophysical and structural biology research. The EM ladder can be used for high-resolution reconstructions but ensure the quality and reproducibility of data. Furthermore, this standardization endeavor extends to imaging settings, offering a reliable foundation for electron microscopes to consistently cater to a diverse array of biological samples. As cryoEM methodologies continue to evolve, control experiments form a necessary foundation of consistency and precision for integrative analysis. Taken together, the cryoEM calibration standard concept facilitates cross-disciplinary structural biology methodologies that rely on the reproducibility of cryoEM data. Conflicts of interest The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. Data availability The cryoEM maps of all four components processed following the workflows described here were deposited to the Electron Microscopy Data Bank (EMDB) with accession codes: Human Apoferritin: EMD-41923, β-galactosidase: EMD-41919, PP7 virus-like particles: EMD-41917, and Tobacco mosaic virus: EMD-41924. Electron micrographs were made available at the Electron Microscopy Image Archive (EMPIAR) with accession code EMPIAR-11693. VLP aliquots may be provided upon request. Acknowledgements This work was performed at the Simons Electron Microscopy Center located at the New York Structural Biology Center, supported by grants from the Simons Foundation (SF349247), NYSTAR, NY State Assembly, and the NIH National Institute of General Medical Sciences (GM103310) with additional support from U24 GM129539. We thank Louise Fairall and Christos Savvy from the Protex facility at the University of Leicester for ferritin human H chain, and Ruben Diaz-Avalos from the La Jolla Institute for Immunology for the tobacco mosaic virus samples. Footnotes https://doi.org/10.6019/EMPIAR-11693 References 1. ↵ Mills DJ . Setting up and operating a cryo-EM laboratory . Q Rev Biophys . 2021 Jan 8; 54 : e2 . PMID: 33413714 OpenUrl PubMed 2. ↵ Alink LM , Eng ET , Gheorghita R , Rice W , Cheng A , Carragher B , Potter CS . System Environmental Metrics Collector for EM facilities [Internet] . bioRxiv ; 2021 [cited 2024 Jul 22 ]. p. 2021.11.04.467268. Available from: https://www.biorxiv.org/content/10.1101/2021.11.04.467268v1 3. ↵ Kim LY , Rice WJ , Eng ET , Kopylov M , Cheng A , Raczkowski AM , Jordan KD , Bobe D , Potter CS , Carragher B. Benchmarking cryo-EM Single Particle Analysis Workflow . Front Mol Biosci . 2018 ; 5 : 50 . PMCID: PMC6009202 OpenUrl 4. Danev R , Yanagisawa H , Kikkawa M. Cryo-EM performance testing of hardware and data acquisition strategies . Microsc Oxf Engl . 2021 Nov 24; 70 ( 6 ): 487 – 497 . PMID: 33969878 OpenUrl PubMed 5. ↵ Gijsbers A , Zhang Y , Gao Y , Peters PJ , Ravelli RBG . Mycobacterium tuberculosis ferritin: a suitable workhorse protein for cryo-EM development . Acta Crystallogr Sect Struct Biol . 2021 Aug 1; 77 ( Pt 8 ): 1077 – 1083 . PMCID: PMC8329864 OpenUrl 6. ↵ Bartesaghi A , Aguerrebere C , Falconieri V , Banerjee S , Earl LA , Zhu X , Grigorieff N , Milne JLS , Sapiro G , Wu X , Subramaniam S. Atomic Resolution Cryo-EM Structure of β-Galactosidase . Struct Lond Engl 1993 . 2018 Jun 5; 26 ( 6 ): 848 - 856 .e3. PMCID: PMC6129192 OpenUrl 7. Yip KM , Fischer N , Paknia E , Chari A , Stark H. Atomic-resolution protein structure determination by cryo-EM . Nature . 2020 Nov ; 587 ( 7832 ): 157 – 161 . PMID: 33087927 OpenUrl CrossRef PubMed 8. ↵ Nakane T , Kotecha A , Sente A , McMullan G , Masiulis S , Brown PMGE , Grigoras IT , Malinauskaite L , Malinauskas T , Miehling J , Uchański T , Yu L , Karia D , Pechnikova EV , de Jong E , Keizer J , Bischoff M , McCormack J , Tiemeijer P , Hardwick SW , Chirgadze DY , Murshudov G , Aricescu AR , Scheres SHW . Single-particle cryo-EM at atomic resolution . Nature . 2020 Nov ; 587 ( 7832 ): 152 – 156 . PMCID: PMC7611073 OpenUrl CrossRef PubMed 9. ↵ Zhao L , Kopylov M , Potter CS , Carragher B , Finn MG . Engineering the PP7 Virus Capsid as a Peptide Display Platform . ACS Nano . 2019 Apr 23; 13 ( 4 ): 4443 – 4454 . PMCID: PMC6991139 OpenUrl CrossRef 10. ↵ Suloway C , Pulokas J , Fellmann D , Cheng A , Guerra F , Quispe J , Stagg S , Potter CS , Carragher B. Automated molecular microscopy: the new Leginon system . J Struct Biol . 2005 Jul ; 151 ( 1 ): 41 – 60 . PMID: 15890530 OpenUrl CrossRef PubMed Web of Science 11. ↵ Zheng SQ , Palovcak E , Armache JP , Verba KA , Cheng Y , Agard DA . MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy . Nat Methods . 2017 Apr ; 14 ( 4 ): 331 – 332 . PMCID: PMC5494038 OpenUrl CrossRef PubMed 12. ↵ Lander GC , Stagg SM , Voss NR , Cheng A , Fellmann D , Pulokas J , Yoshioka C , Irving C , Mulder A , Lau PW , Lyumkis D , Potter CS , Carragher B. Appion: an integrated, database-driven pipeline to facilitate EM image processing . J Struct Biol . 2009 Apr ; 166 ( 1 ): 95 – 102 . PMCID: PMC2775544 OpenUrl CrossRef PubMed Web of Science 13. ↵ Eng ET , Kopylov M , Negro CJ , Dallaykan S , Rice WJ , Jordan KD , Kelley K , Carragher B , Potter CS . Reducing cryoEM file storage using lossy image formats . J Struct Biol . 2019 Jul 1; 207 ( 1 ): 49 – 55 . PMCID: PMC6597182 OpenUrl 14. ↵ Tang G , Peng L , Baldwin PR , Mann DS , Jiang W , Rees I , Ludtke SJ . EMAN2: an extensible image processing suite for electron microscopy . J Struct Biol . 2007 Jan ; 157 ( 1 ): 38 – 46 . PMID: 16859925 OpenUrl CrossRef PubMed Web of Science 15. ↵ Punjani A , Rubinstein JL , Fleet DJ , Brubaker MA . cryoSPARC: algorithms for rapid unsupervised cryo-EM structure determination . Nat Methods . 2017 Mar ; 14 ( 3 ): 290 – 296 . PMID: 28165473 OpenUrl CrossRef PubMed 16. ↵ Kopylov M , Kelley K , Yen LY , Rice WJ , Eng ET , Carragher B , Potter CS . Horse spleen apoferritin light chain . 2019 . doi: 10.2210/pdb6PXM/pdb OpenUrl CrossRef 17. ↵ Neselu K , Wang B , Rice WJ , Potter CS , Carragher B , Chua EYD . Measuring the effects of ice thickness on resolution in single particle cryo-EM . J Struct Biol X . 2023 ; 7 : 100085 . PMCID: PMC9894782 OpenUrl CrossRef 18. Henderson R , McMullan G. Problems in obtaining perfect images by single-particle electron cryomicroscopy of biological structures in amorphous ice . Microsc Oxf Engl . 2013 Feb ; 62 ( 1 ): 43 – 50 . PMCID: PMC3767125 OpenUrl 19. ↵ Russo CJ , Passmore LA . Electron microscopy: Ultrastable gold substrates for electron cryomicroscopy . Science . 2014 Dec 12; 346 ( 6215 ): 1377 – 1380 . PMCID: PMC4296556 OpenUrl Abstract / FREE Full Text 20. ↵ Chan LM , Courteau BJ , Maker A , Wu M , Basanta B , Mehmood H , Bulkley D , Joyce D , Lee BC , Mick S , Czarnik C , Gulati S , Lander GC , Verba KA . High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector . J Struct Biol . 2024 Jun 27; 216 ( 3 ): 108108 . PMID: 38944401 OpenUrl PubMed 21. Sun M , Azumaya CM , Tse E , Bulkley DP , Harrington MB , Gilbert G , Frost A , Southworth D , Verba KA , Cheng Y , Agard DA . Practical considerations for using K3 cameras in CDS mode for high-resolution and high-throughput single particle cryo-EM . J Struct Biol . 2021 Sep ; 213 ( 3 ): 107745 . PMID: 33984504 OpenUrl CrossRef PubMed 22. ↵ Peng R , Fu X , Mendez JH , Randolph PS , Bammes BE , Stagg SM . Characterizing the resolution and throughput of the Apollo direct electron detector . J Struct Biol X . 2023 ; 7 : 100080 . PMCID: PMC9791170 OpenUrl View the discussion thread. Back to top Previous Next Posted August 05, 2024. Download PDF Supplementary Material Data/Code Email Thank you for your interest in spreading the word about bioRxiv. NOTE: Your email address is requested solely to identify you as the sender of this article. Your Email * Your Name * Send To * Enter multiple addresses on separate lines or separate them with commas. You are going to email the following Multi-species cryoEM calibration and workflow verification standard Message Subject (Your Name) has forwarded a page to you from bioRxiv Message Body (Your Name) thought you would like to see this page from the bioRxiv website. Your Personal Message CAPTCHA This question is for testing whether or not you are a human visitor and to prevent automated spam submissions. Share Multi-species cryoEM calibration and workflow verification standard Daija Bobe , Mykhailo Kopylov , Jessalyn Miller , Aaron P. Owji , Edward T. Eng bioRxiv 2024.08.05.606612; doi: https://doi.org/10.1101/2024.08.05.606612 Share This Article: Copy Citation Tools Multi-species cryoEM calibration and workflow verification standard Daija Bobe , Mykhailo Kopylov , Jessalyn Miller , Aaron P. Owji , Edward T. Eng bioRxiv 2024.08.05.606612; doi: https://doi.org/10.1101/2024.08.05.606612 Citation Manager Formats BibTeX Bookends EasyBib EndNote (tagged) EndNote 8 (xml) Medlars Mendeley Papers RefWorks Tagged Ref Manager RIS Zotero Tweet Widget Facebook Like Google Plus One Subject Area Biochemistry Subject Areas All Articles Animal Behavior and Cognition (7643) Biochemistry (17717) Bioengineering (13910) Bioinformatics (42018) Biophysics (21480) Cancer Biology (18629) Cell Biology (25537) Clinical Trials (138) Developmental Biology (13392) Ecology (19935) Epidemiology (2067) Evolutionary Biology (24356) Genetics (15617) Genomics (22531) Immunology (17755) Microbiology (40438) Molecular Biology (17200) Neuroscience (88706) Paleontology (667) Pathology (2840) Pharmacology and Toxicology (4832) Physiology (7657) Plant Biology (15171) Scientific Communication and Education (2046) Synthetic Biology (4304) Systems Biology (9828) Zoology (2272)
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.