Robotic-Assisted Laparoscopic Repair of Post-Hysterectomy Vesicovaginal Fistula Using Omental Interposition Flap
OA: gold
AI-generated summary
This video article demonstrates a robotic-assisted laparoscopic technique for repairing post-hysterectomy vesicovaginal fistula using an omental interposition flap, presented as a seven-step systematic repair.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
Study Objective To demonstrate, via robotic-assisted laparoscopy, a transperitoneal technique for repair of post-hysterectomy vesicovaginal fistula (VVF) using an omental interposition flap. Design Video article. Setting University Hospital and referral center for Gynaecological disease. Patients or Participants A 52-year-old woman with VVF after laparoscopic hysterectomy. Interventions Repair of post-hysterectomy VVF with omental flap interposition. Measurements and Main Results A 52-year-old woman with a history of menorrhagia refractory to medical treatment underwent a total laparoscopic hysterectomy and bilateral salpingectomy. Histology of the uterus showed multiple uterine fibroids and adenomyosis. Twelve days following the hysterectomy, she developed leakage of urine per vagina. Computed tomography scan and cystourethrogram demonstrated normal ureters and presence of a vesicovaginal fistula. An indwelling catheter was inserted to rest the bladder and allow the acute inflammation surrounding the fistula to subside prior to definitive surgical repair six weeks later. The repair consisted of seven steps: 1. Restoration of anatomy2 Opening the vaginal vault3 Identification of fistula defect4 Resection of fistula tract5 Dissection of vesicovaginal space6 Closure of vesical and vaginal defects7 Interposition of omental graft The patient was discharged 48 hours after surgery. The indwelling catheter was maintained for 14 days. Cystourethrogram was carried out to confirm the integrity of the bladder prior to catheter removal. There was no further vaginal loss. Clinical follow up at six weeks and three months post-repair showed no bladder or vaginal dysfunction. Conclusion Robotic-assisted laparoscopy is a feasible approach for repair of VVF, which can be performed systematically using seven steps. This technology lends itself well to procedures requiring intricate dissection and multi-layered suturing as demonstrated in this case.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-09-15T06:16:59.523076+00:00