Fully Automated Delineation of the Optic Radiation for Surgical Planning using Clinically Accessible Sequences
preprint
OA: closed
Abstract
1 Quadrantanopia caused by inadvertent severing of Meyer’s Loop of the optic radiation is a well-recognised complication of temporal lobectomy for conditions such as epilepsy. Dissection studies indicate that the anterior extent of Meyer’s Loop varies considerably between individuals. Quantifying this for individual patients is thus an important step to improve the safety profile of temporal lobectomies. Previous attempts to delineate Meyer’s Loop using diffusion MRI tractography have had difficulty estimating its full anterior extent, required manual ROI placement, and/or relied on advanced diffusion sequences that cannot be acquired routinely in most clinics. Here we present CONSULT – a pipeline that can delineate the optic radiation from raw DICOM data in a completely automated way via a combination of robust preprocessing, segmentation, and alignment stages, plus simple improvements that bolster the efficiency and reliability of standard tractography. We tested CONSULT on 694 scans of predominantly healthy participants (538 unique brains), including both advanced acquisitions and simpler acquisitions that could be acquired in clinically acceptable timeframes. Delineations completed without error in 99.4% of the scans. The distance between Meyer’s Loop and the temporal pole closely matched both averages and ranges reported in dissection studies for all tested sequences. Median scan-rescan error of this distance was 1mm. When tested on two participants with considerable pathology, delineations were successful and realistic. Through this, we demonstrate not only how to identify Meyer’s Loop with clinically accessible sequences, but also that this can be achieved without fundamental changes to tractography algorithms or complex post-processing methods. Highlights We propose a fully automated means of delineating the optic radiation using diffusion MRI from DICOM data Anatomical measurements from tractography of over 500 brains align well with previous dissection studies The proposed pipeline works well with clinically accessible and advanced acquisitions Median scan-rescan error was 1mm Plausible tractography was generated when pathology was present
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00