Analysis of 14 β-Agonists in Pork Using Automated Wooden Tip Based SPME Device and UPLC-MS/MS
preprint
OA: closed
AI-generated summary
This study developed an automated wooden tip SPME-UPLC-MS/MS method for detecting 14 β-agonists in pork, demonstrating high recovery, low detection limits, and improved accuracy compared to national standards.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
Abstract
This study presents an innovative analytical method for the detection and quantification of 14 β-agonists in pork using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method involves the use of a solid phase microextraction (SPME) probe, consisting of a wooden tip coated with polyacrylonitrile (PAN) and molecularly imprinted polymer (MIP). This probe has been integrated into an automated extraction device, designed in our laboratory to extract the target analytes prior to LC-MS/MS analysis. Compared to the traditional solid-phase extraction (SPE) procedure, the proposed approach significantly reduces the costs related to adsorbent ma-terial and solvent consumption, and shortens purification time, thereby reducing both the tech-nical workload and associated expenses. The methodology has been carefully validated in ac-cordance with the National Standard of the People's Republic of China (GB/T 22286-2008), evalu-ating key parameters including the limit of detection (LOD), limit of quantification (LOQ), matrix effects, linearity, and both intra-day and inter-day precision. The average recovery rates for all β-agonists were observed to lie between 71.6% and 82.2%, with relative standard deviations (RSDs) consistently below 15% for both types of precision. The LOD and LOQ values were found to range from 0.09 to 0.39 μg/kg and 0.27 to 0.99 μg/kg, respectively. In terms of accurate detection of positive samples, the developed method demonstrated a closer approximation to the true value of the sample compared to the National Standard method GB/T 31658.22-2022. Overall, the proposed method exhibits substantial promise for the routine assessment of β-agonists in pork and presents a practical alternative for compliance monitoring in regulatory settings.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00