Polyetheretherketone for Craniomaxillofacial Defects: Cases Report, Evaluation of Patients’ Satisfaction and a Systematic Literature Review | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Research Article Polyetheretherketone for Craniomaxillofacial Defects: Cases Report, Evaluation of Patients’ Satisfaction and a Systematic Literature Review Yuliya Menchisheva, Alvaro Varela Morillas, Nunzianda Frascione This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-7289687/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 24 Oct, 2025 Read the published version in Maxillofacial Plastic and Reconstructive Surgery → Version 1 posted 11 You are reading this latest preprint version Abstract Background : Craniomaxillofacial reconstruction poses significant clinical challenges due to the complexity of the anatomy and the varied causes of defects. Selecting the optimal implant material remains a crucial factor in achieving successful functional and aesthetic outcomes. This study combined a systematic review and a retrospective case series conducted at the Hospital 5, Almaty, Kazakhstan. The sample consisted of 52 patients who underwent craniomaxillofacial reconstruction between 2021 and 2024, receiving either PEEK, titanium, PMMA, or silicone implants. Following the surgical procedures, patients were invited to participate in an online survey to evaluate their satisfaction with long-term outcomes. Results : PEEK implants demonstrated the complication rate at 22.2%, attributable only to hematoma. Titanium implants exhibited the complication rate - 22.7%, with cases of asymmetry and diplopia (4.5%), exposure (9.1%), hematoma (4.5%), and infection with rejection (9.1%). Aesthetic outcome scores, measured by the ANA scale, varied across materials. PEEK implants achieved the highest mean ANA rating with 8.86 (SD=0.35; 8.25 – 9.25), showing a significant difference over PMMA, silicone and titanium . Conclusions : PEEK implants demonstrated promising clinical and aesthetic outcomes in craniomaxillofacial reconstruction. However, material selection should be personalised, considering defect location, soft tissue coverage to optimise results. PEEK Reconstruction Surgical procedures Postoperative complications Patient outcome assessment Implant materials Figures Figure 1 Figure 2 Figure 3 Figure 4 1. Introduction Reconstruction of defects in the maxillofacial region poses an ongoing challenge for clinicians. Different biomaterials such as titanium, autologous bone grafts, and polymers are being used for facial defect reconstruction ( 1 ). However, for larger and more complex defects, physicians are still struggling to find optimal solutions that can improve clinical and aesthetic outcomes and ensure patient satisfaction with the treatment results ( 2 ). Facial bone defects can cause facial deformities, impairments in chewing and speech, and have a profound impact on the physical and mental health of patients, seriously reducing their quality of life ( 3 ). These defects and deformities in maxillofacial area could be congenital or acquired, resulting from traumas, resection due to benign and malignant tumours, odontogenic and non-odontogenic infections as well as osteonecrosis. The main groups of alloplastic materials for facial plastic and reconstructive surgery include metals such as titanium, silicone, polymers like polyethylene, methylmethacrylate and polyetheretherketone (PEEK) and ceramics like hydroxyapatite ( 4 ). Depending on the intended use of an implant materials’ (load-bearing or aesthetic region) the distinct qualities of the material should be carefully considered before their application ( 5 ). Recent reports acknowledge that PEEK implants are an excellent treatment option and could effectively restore both bone and soft tissue deformities in facial surgery, meeting patients' desires and requirements for reconstructive or cosmetic purposes ( 6 – 12 ). PEEK is a polyaromatic semi-crystalline thermoplastic polymer which has all the mechanical properties suitable for bio-medical applications ( 13 ). It is a lasting material which is widely used in different fields of medicine especially for surgical purposes including oral and maxillofacial, orthopaedic, spine, plastic and reconstructive surgeries. Its benefits within the field of reconstructive surgery have been significantly supported by various studies ( 9 , 10 , 14 , 15 ). Over the past decade, there have been several reports on the utilization of PEEK material in maxillofacial reconstructive surgery. These reports are based on the analysis of sequential clinical cases ( 2 , 16 – 18 ). However, further studies with larger cohorts and comparative analysis with alternative implant materials are needed to validate the accuracy of these findings. The purpose of this study was to perform a comprehensive systematic review of the literature and to conduct a retrospective review of clinical cases to evaluate the various materials utilized for craniomaxillofacial reconstruction, comparing their advantages, disadvantages, clinical applications, mechanical properties, aesthetical outcomes, and complications. Patient satisfaction with surgical outcomes was also evaluated in the long-term postoperative period through an online survey. The authors of this study hypothesize that PEEK implants offer superior clinical and aesthetical outcomes in craniomaxillofacial reconstruction compared to titanium, PMMA and silicone, due to its favourable mechanical properties and biocompatibility. Further, it is proposed that careful patient selection and implant material choice will optimize outcomes and patient satisfaction. The specific aims of this study were to: 1) systematically review the literature on materials used for craniomaxillofacial reconstruction, 2) compare the advantages and disadvantages of widely used implant materials based on clinical applications, mechanical properties, biocompatibility, aesthetic outcomes, and complications, 3) analyse a retrospective review of 52 cases of craniomaxillofacial reconstruction surgeries to share insights from past clinical experience, including surgical outcomes and complications, 4) evaluate patient satisfaction with surgical outcomes in the long-term postoperative period through an online survey. The findings from this study contribute to the growing body of evidence regarding material selection in craniomaxillofacial reconstruction. By combining a systematic review of the literature with clinical data and patient satisfaction surveys, this research provides a multifaceted evaluation of implant materials. 2. Material and methods The protocol for this study was registered in PROSPERO (ID: CRD420251079557, https://www.crd.york.ac.uk/PROSPERO/view/CRD420251079557 ) and compiled by the Preferred Items for Systematic Reviews and Meta-Analyses (PRISMA) reporting guidelines.( 19 ) The study selection process is illustrated using the PRISMA flow chart.( 20 ) Supplemental materials have more details on the search methodology. 2.1 Eligibility criteria Specific inclusion and exclusion criteria to ensure the selection of relevant studies were established (Supplemental Table 1). 2.2 Search strategy The Population, Intervention, Comparison, Outcome (PICO) framework was applied to ensure a structured and systematic approach to formulating the research question and guiding the literature search. PICO Framework : • Population (P): Patients with maxillofacial defects who underwent reconstructive surgery. • Intervention (I): Use of PEEK implants for reconstruction. • Comparison (C): Other implant materials such as titanium, polymethylmethacrylate (PMMA), silicone, polyethylene, hydroxyapatite. • Outcome (O): clinical outcomes (implant success rates, complication rates), patient satisfaction, functional outcomes (improvement in chewing, speech, and overall quality of life). A literature search for the review of facial implant materials in maxillofacial surgery was conducted through MEDLINE (PubMed), EMBASE and The Cochrane Library databases. All human studies published in the English language from the year 2000 onwards reporting on implants used in facial reconstruction were considered eligible for inclusion. The electronic search strategy was based on specific inclusion criteria, utilizing a combination of Medical Subject Headings (MeSH) and entry terms. The following search terms were applied: (“PEEK implants” OR “polyetheretherketone implants” OR “titanium implants” OR “PMMA implants” OR “silicone implants” OR “polyethylene implants” OR “hydroxyapatite implants”) AND (“maxillofacial reconstruction” OR “facial bone defects” OR “craniofacial reconstruction”) AND (“patient satisfaction” OR “clinical outcomes” OR “aesthetical outcomes” OR “complication” OR “functional outcomes”). According to the inclusion and exclusion criteria, the articles were chosen based on their titles and abstracts (Appendix A). 2.3 Selection process All the studies retrieved were screened in two stages using Rayyan software for systematic review. First, two independent reviewers evaluated the titles and abstracts to determine relevance. Then, full texts of the selected studies were reviewed, and only those meeting the inclusion and exclusion criteria were considered eligible for analysis. 2.4 Data collection process EndNote, a reference management software, was used to streamline the data collection and organisation process. Duplicate articles were removed. The articles were selected by title and abstract for relevance according to the specified inclusion and exclusion criteria outlined below. All abstracts were independently reviewed. Any disagreements were resolved by the third author's involvement (AM)( 21 ). Google Scholar Alerts was used to update citations extended to 31st March 2025 in order to ensure the inclusion of the most recent and relevant publications. 2.5 Study risk of bias assessment The risk of bias assessment was conducted using two validated tools based on study design. The Joanna Briggs Institute (JBI) critical appraisal checklist (Australia, JBI) was used for case reports and case series. For retrospective and prospective studies, the Risk of Bias in Non-Randomised Studies of Interventions (ROBINS-I) (UK, Cochrane) was applied to assess potential biases in studies. 2.6 Selection Criteria The inclusion and exclusion criteria for study eligibility were established in the study protocol. The current evaluation covered every kind of clinical investigation involving human participants, including controlled clinical trials, prospective and retrospective studies, case series, and case reports. On the other hand, review papers and experiments conducted in vitro or on animals were not included. The records where the titles and abstracts included the words “dental”, “prosthetic rehabilitation”, “use of injectable implants/fillers”, literature reviews without clinical cases, systematic reviews, meta-analysis, in-vitro studies and animal studies were excluded. 2.7 Retrospective study Data from medical records of all 18–74 years old patients who underwent maxillofacial reconstruction procedures using different implant materials such as PEEK, titanium, PMMA and silicone at Hospital 5 in Almaty, Kazakhstan, between 2021 and 2024 were collected. The informed consent for the use of patient data was obtained through an ethical process. The hospital administrator initially contacted eligible patients via phone, explaining the study’s purpose and requesting verbal consent for the retrospective analysis of existing medical records. The study protocol was approved by the Research Ethics Committee of King’s College London (Ref. number LRS/DP-24/25-4531 from October 3, 2024). Data such as age, sex, diagnosis, localization of the bone defect or deformity, cause of the bone defect or deformity, material of the implant that was used for reconstruction, type of reconstruction (primary or delayed), duration of operation in minutes, number of occupied bed days, postoperative complications, comorbidities, bad habits, presence of preoperative or postoperative radiotherapy or bisphosphonate medication were collected. All data were anonymised. Assessment of the incidence of complications, such as infection, hematoma, implant failure and others, following facial reconstructions using PEEK, titanium, PMMA and silicone implants was also provided. Surgical technique: All surgeries were performed under general anaesthesia using standardised protocols by the same surgical team. Implant fit was pre-planned using CAD/CAM (Computer-aided design and manufacturing) design and patient-specific 3D models. All implants were customised and fabricated according to defect location and contour. PEEK implants were fixated using self-tapping titanium screws (1.5-2.0 mm), with bicortical engagement where possible, typically in 3–4 quadrants. Titanium implants fixation followed standard osteosynthesis principles. PMMA implants were prefabricated preoperatively and sterilised using ethylene oxide. Implants were seated into the defect and secured with titanium screws to the surrounding bone. Silicone implants were preformed and positioned in subperiosteal pockets. Fixation was performed using titanium microscrews. Hemostasis was carefully achieved using bipolar cautery and absorbable hemostatic agents. In all xases, layered wound closure was performed with resorbable 3 − 0, 4 − 0 or 5 − 0 sutures. A closed-suction drain was placed where indicated and removed after 24–48 hours. Postoperative protocol: Postoperative care included antibiotics (ceftriaxone 1g IV for 5 days). Analgesia was administered via NSAIDs. Wound care involved sterile dressing changes every 24 hours until suture removal (at day 7–10). Patients were monitored in the inpatient ward for an average6.13±0.23 days. All patients underwent standardised clinical follow-up at 1 week, 1 month, 3 months, and 12 months postoperatively. Complications were assessed during each follow-up period by the same clinical team using a uniform checklist. 2.8 Aesthetic outcomes The study included an assessment of the aesthetic outcomes of patients who already underwent surgical procedures using different implant materials for maxillofacial defects and deformities at Hospital 5 in Almaty, Kazakhstan between the years 2021 and 2024. The survey was conducted anonymously using a structured questionnaire. The questionnaire was designed using the Google Forms application to assess the patient's satisfaction with the aesthetic outcome of their surgery. For the online survey, additional consent was obtained. All participants received the information sheet and consent form via WhatsApp. A series of questions rated on an eleven-point scale according to the “Aesthetic Numeric Analogue” (ANA) were included (Fig. 1 ). Patients were asked to select the word that best described their level of satisfaction with the aesthetic results of their reconstructive surgery. The responses from the questionnaires were collected and coded numerically, with each descriptor assigned a specific score. The survey was conducted in accordance with the ethical standards of the committee responsible for human experimentation (institutional and national), and with the Helsinki Declaration of 1975, as revised in 2013 ( http://ethics.iit.edu/ecodes/node/3931 ). Written consent was obtained from all parents/legal guardians of participants enrolled in the study. 2.9 Statistical analysis Descriptive statistics summarised the patient characteristics and outcomes. Chi-square tests compared the complication rates, while the Kruskal-Wallis test was used to analyse aesthetic outcomes across the four implant materials (PEEK, titanium, PMMA, silicone). To evaluate the adequacy of the sample size for detecting differences in complication rates among the four implant material groups, a post-hoc power analysis was conducted using G*Power 3.1. software. The analysis assumed an effect size f = 0.35 (medium-to-large), α = 0.05, and power 1 - β = 0.80. The observed effect sizes were computed and interpreted with corresponding 95% confidence intervals. Additionally, power calculations were repeated using smaller effect sizes (f = 0.20–0.25) to determine the minimum detectable differences under more conservative assumptions. 3. Results 3.1 Systematic literature review There were 3685 patients in 150 studies overall. There were 42 studies (with 821 patients) in the titanium group, 12 studies (with 806 patients) in the silicone group, 24 studies (with 914 patients) in the polyethylene group, 18 studies (with 382 patients) in the acrylic material - PMMA group, 41 studies (with 479 patients) in the PEEK group, 13 studies (with 283 patients) in the hydroxyapatite group. The PRISMA flow diagram is illustrated in Fig. 2 . 3.1.1 Titanium Titanium is widely used in reconstructive maxillofacial surgery, particularly for zygomatic-orbital defects, due to its high mechanical strength, corrosion resistance and biocompatibility ( 22 ). The main advantages of titanium implants are their durability, stability, rigidity and ability to provide osseointegration ( 13 , 23 ). However, titanium’s extreme rigidity limits its use in aesthetic augmentation. Its thermal sensitivity can result in an uncomfortable sensation of cold that frequently leads to removal due to the implant's higher heat conductivity than the surrounding tissues ( 24 ). It also produces imaging artifacts and carries risks of implant rejection ( 25 ). Studies also highlighted the challenges in precise reconstruction with titanium ( 26 ). Pietzka et al. ( 27 ) reported a 66.6% inaccuracy rate in orbital reconstructions using patient-specific titanium implants. In the zygomatic-orbital region, implant exposure has been observed due to thin overlying soft tissue, compromising cosmetic results ( 13 ), ( 28 – 30 ). Titanium nasal implants, introduced in 2003, aimed to improve airway patency ( 31 ). Titanium meshes and plates are often used for structural support in reconstructive surgery and to replicate maxillary or mandibular contours ( 32 , 33 ). Mounir et al. ( 34 ) documented three failures out of seven cases using patient-specific titanium endoprostheses for mandibular reconstruction, due to mucosal dehiscence and fistula formation. In contrast, Woo et al. ( 35 ) demonstrated successful contour restoration of the mandibular angle and its lower border using titanium implants. Although titanium is corrosion-resistant, allergic reactions have been reported ( 36 ) ( 37 ) ( 38 ). 3.1.2 Silicone Silicone is widely used in facial skeleton implants especially for aesthetic purposes. Silicone implants can be premanufactured (i.e., malar, chin, mandibular implants) or a silicone block can be used, from which the surgeon cuts out the required sized implant. It is worth to acknowledge that this material has higher incidence of infections and displacements, depending on the implanted area ( 39 ). The chin and mandibular area are considered the safest, while malar implants have a high incidence of prominence ( 40 ). However, Al-Jandan et al. ( 41 ) reported cases of displacement of silicone implants in mandibular angle augmentation. According to a recent narrative review by Gafar Ahmed et al. ( 39 ) silicone implantation has a range of complications such as asymmetry, bone resorption or erosion, displacement, dissatisfaction, oedema, hematoma, infection, mucosal irritation, pain, and paraesthesia. Over time, the substance usually becomes encapsulated by a fibrous membrane and is not integrated into the host. This makes removal easier but needed due to seroma formation, extrusion, undesired implant displacement, and poor cosmetic results ( 25 ). In comparison to porous polyethylene and hydroxyapatite, silicone implants had one of the highest removal rates according to Rubin et al. ( 42 ) It is worth acknowledging that the use of silicone implants is popular among cases of augmentation rhinoplasty. Despite its benefits, using silicone implants can lead to negative outcomes, including contracture deformity, immediate and delayed infection, and an improper implant contour necessitating revision surgery ( 43 ). Poor implant location and selection may be the cause of most malformations. The replacement of existing grafts with specially carved silicone implants achieves the desired aesthetic results ( 44 ). The utilization of cheek silicone implants has proven to be an excellent technique for rejuvenating midfacial volume. The main challenge in this operation lies in choosing the right type, shape, and size of the silicone implant ( 45 ). 3.1.3 Polyethylene As an alternative to bone grafts, polyethylene is a biocompatible, porous, high-density implant material. It is commonly used in aesthetic plastic surgery for contour enhancement in cases of rhinoplasty, chin, mandibular and malar augmentation. In addition, polyethylene is utilized in congenital malformations, closure of post-traumatic defects and reconstruction after tumour removal ( 46 ). Significant vascular and soft-tissue ingrowth is made possible by its porous nature. Soft tissue ingrowths, collagen deposition, and eventual vascularization were confirmed by biopsies in a recent study by Niechajev ( 47 ). One of the most popular applications in the use of polyethylene is auricular reconstruction for congenital malformations. The synthetic polyethylene material called Medpor is currently used to replace missing face cartilage, although it is not a suitable substitute for complex defects reconstruction due to its high rate of surgical complications, such as infection and extrusion ( 48 ). Also, porous polyethylene implants are widely used with rib cartilage for microtia reconstruction. According to Ku et al. in their study 5 (15.2%) of 33 hybrid frameworks cases (polyethylene + rib) were removed due to infection or extrusion, which is considered as a high explantation rate ( 49 ). However, according to different recent research, nasal and paranasal augmentation using porous polyethylene is a dependable technique that causes the least amount of morbidity in patients with soft tissue insufficiency ( 50 , 51 ). 3.1.4 Polymethyl methacrylate Polymethyl methacrylate (PMMA) has been applied to numerous cases of orbital ( 52 ), fronto-orbital ( 53 , 54 ), zygomatic reconstruction and cranioplasty ( 55 , 56 ), midface and mandibular augmentation ( 57 ). PMMA is a biocompatible and nondegradable acrylic resin-based implant ( 58 ); and it also presents radiolucent properties, which makes it hard to detect in radiographs but benefits in ease post-operative imaging in the follow-up period ( 59 ). PPMA implants are encapsulated during the time with fibrous connective tissue. If pathology recurs and revision surgery is necessary, this guarantees a straightforward removal ( 60 ). The initial flexibility of the material can be attributed to the combination of the liquid polymer and the monomeric powder. Eventually, the substance undergoes an exothermic reaction and solidifies into a highly resilient material, achieving the desired shape ( 61 ). Bruens et al. ( 56 ) reported long-term results of using the porous form of PMMA in patients with craniofacial defects over 20 years. An aqueous, biodegradable carboxymethylcellulose gel was dispersed to create pores in implants. PMMA was prepared using the traditional bone cement composition of methylmethacrylate liquid and PMMA powder. The pores provided space for bone resorption improving prosthesis fixation. Jain et al. ( 57 ) believe that patient-specific PMMA implants have become the gold standard for reconstructing cranial abnormalities, with outstanding long-term outcomes. However, PMMA was shown to have a relative rate of hematoma formation and infection following implantation, according to a meta-analysis of facial implant materials ( 62 ). On the other hand, the meta-analysis conducted by Leao et al. ( 63 ) indicated that the use of PMMA yields complication rates near those of autologous bone and titanium mesh. PMMA material is not usually used for midfacial augmentation or reconstruction, especially in load-bearing areas, because of the difficulty in reshaping it, the risk of infections and plate fractures, and the lack of osseointegration ( 13 ). 3.1.5 Bioceramics Recent studies have demonstrated that hydroxyapatite (HA) based implants outperform other alloplastic implants in terms of promoting cellular adhesion and integration ( 64 – 67 ). HA plates are used for grafting facial bones, such as zygoma, maxilla and mandible. The remarkable bio-acceptance of HA for facial augmentation was confirmed by the authors' discovery that the HA granules are enveloped by host collagen and gradually replaced by neo-bone, including osteoblasts and osteocytes ( 68 ). Another main advantage of using HA implants is their biocompatibility. As HA is a naturally occurring mineral found in human bones, there is a lower risk of immune rejection or adverse reactions compared to other materials ( 65 ). This also means that the implant is less likely to cause inflammation or infection. However, it works well when used in the form of plates and meshes, while solid implants are significantly brittle. Researchers have reported that HA implants have a lower mechanical strength and toughness than titanium and PEEK implants, which make HA implants more prone to fracture or failure under mechanical stress, especially in load-bearing areas such as the mandible and maxilla ( 69 ). Zhang et al. ( 70 ) emphasised the lack of confidence on the optimal balance between strength and osseointegration. 3.1.6 Polyetheretherketone The use of PEEK implants in maxillofacial reconstructive surgery has gained significant popularity in recent years due to its many advantages over other implant materials. Commercialized for industry in the 1980s ( 71 ), PEEK first described in cranioplasty by Hanasono et al. and has gained popularity since the early 2000s ( 72 ). According to Ma et al. ( 73 ), PEEK contains an aromatic molecular backbone and functional groups located between the acrylic rings that are a mix of ether and ketone. PEEK has superior mechanical properties including high strength, stiffness, and toughness which make it an ideal material for load-bearing applications ( 7 , 15 , 74 ). When compared to alternative alloplastic implant materials, PEEK offers a number of benefits. PEEK does not cause artifacts on radiographic imaging and exhibits radiographic translucency, greatly enhancing picture quality, making it easier to radiologically analyse the tissues surrounding the implant ( 75 ). This is advantageous for CT-based adjuvant radiation planning and radiological tumor follow-up ( 76 ). In addition, PEEK does not undergo exothermic reactions like methyl methacrylate and is neither allergic nor magnetic ( 77 ). Moreover, PEEK's flexibility is similar to that of cortical bone ( 73 ). However, PEEK's bio-inertia causes challenging osteogenesis and weak osteoconductive qualities ( 78 ). To improve its osteoinductive and antimicrobial capabilities, different types of functionalization of PEEK surfaces and changes in PEEK structure have been proposed by various authors ( 79 , 80 ). In contrast, PEEK implants are a relatively new material and have not been extensively studied in long-term clinical trials. The advantages and disadvantages of the six discussed implant materials used in reconstructive maxillofacial surgery are summarised in Table 1 . Table 1 Main advantages and disadvantages of the most common materials for reconstructive surgery. Material Advantages Disadvantages Titanium Excellent biocompatibility, corrosion resistance, high mechanical strength, osseointegration, not ferromagnetic, durable, stable, rigid. Thermal sensitivity, not translucent - cause radiographic distorge, cosmetic issues, potential for allergic reactions (as a result lead to rejection). Silicone Suitable for aesthetic purposes, flexible, easy removal due to encapsulation. Bone resorption, lack of osseointegration, high infection and displacement rates, high rate of asymmetry due to displacement, high removal rate, poor integration. Polyethylene Allows tissue ingrowth, availability. Thermal sensitivity, hard to remove, high risk of infection and extrusion, lack of rigidity (not ideal for load-bearing areas). PMMA Radiolucent, customizable before polymerization, biocompatible, bone ingrowth in porous form implants, cost-effective. Provide exothermic reaction, difficulty in reshaping after polymerization, lack of osseointegration (non-porous forms), high risk of infection (for porous implants), not load-bearing. Bioceramics (HА) Promotes cellular adhesion and osseointegration, excellent biocompatibility, osseoconductivity, replaced by newly formed bone, low immune rejection risk Brittle, low mechanical strength, prone to fracture, potential infection, less suitable for load-bearing areas. PEEK High strength and stiffness, radiolucent, non-magnetic, resistant to gamma radiation, no thermal reactions and thermal sensitivity, low weight, similar flexibility to bone, steam sterilization. Bio-inert, requires surface modification, poor adhesion, incidence of infection, higher cost, limited long-term data. Anatomical areas of implementation and complications associated with different implant materials in craniomaxillofacial reconstruction were analysed and presented in Appendix B and Fig. 3 . Among 3685 reconstruction cases reviewed, complication rates varied significantly across implant materials. PEEK demonstrated a complication rate of 13.4% (64/479) with the highest patient satisfaction. Titanium had a complication rate of 4.8% (39/821) and remained the preferred material for load-bearing regions, although it presented risks of exposure. PMMA showed an 11.04% (38/382) complication rate and proved effectiveness in cranial reconstructions but was associated with hematomas and dural tears. Polyethelene had the highest complication rate at 15.75% (144/914), with frequent infections and implant exposures. Silicone showed a 13.4% (108/806) complication rate, most commonly involving bone resorption and displacement. HA had a moderate complication rate of 9.5% (27/283), with infection being the primary issue. Statistical comparison using Pearson’s Chi-square test revealed a significant difference in complication rates across the six materials (p < 0.01), underscoring the need for individualised implant selection. These findings highlight the importance of choosing implant materials based on anatomical location, functional demands, and complication profiles to optimise reconstructive outcomes and enhance patient satisfaction. 3.2 Retrospective analysis 3.2.1 Patient characteristics The study population comprised 22 females and 30 males with a mean age of 37.46 ± 1.36 years and with an age range of 18–67 years. The patient characteristics are presented in Table 2 . Table 2 Patient demographics and case characteristics. Sex Female 22 (42.3%) Male 30 (57.7%) Etiology Congenital 12 (23.1%) Infection 2 (3.8%) Systematic disease 2 (3.8%) Trauma 33 (63.5%) Tumor 3 (5.8%) Type of operation Delayed 13 (25.0%) Primary 39 (75.0%) Implant material PEEK 9 (17.3%) Silicone 14 (26.9%) PMMA 6 (11.5%) Titanium 23 (44.23%) Complications Asymmetry 1 (1.9%) Diplopia 1 (1.9%) Exposure 2 (3.8%) Extrusion 2 (3.8%) Hematoma 4 (7.7%) Infection, rejection 2 (3.8%) Mean duration of operation in min 121.06 ± 10.306 Mean number of in-patient department bed days 6.13 ± 0.231 3.2.2 Complications In a retrospective analysis of 52 craniomaxillofacial reconstruction cases, complications varied across the implant materials used. PEEK implants demonstrated a low complication rate, with hematoma occurring in 2 cases (22.2%) and no reports of extrusion, infection, or rejection. PMMA implants showed one case of extrusion (16.7%) but no other complications. Silicone implants exhibited a broader range of complications, including asymmetry (7.1%), extrusion (7.1%), and hematoma (7.1%), accounting for a total complication rate of 21.4%. Titanium implants had the highest complication rate, with cases of asymmetry and diplopia (4.5%), exposure (9.1%), hematoma (4.5%), and infection with rejection (9.1%), resulting in a total complication rate of 22.7% (Table 3 ). Table 3 Complications across the implant materials used during craniomaxillofacial surgeries. Material of implants Complication Valid percent Cumulative percent PEEK hematoma 2 22.2 no 7 77.8 PMMA extrusion 1 16.7 no 5 83.3 Silicone asymmetry 1 7.1 extrusion 1 7.1 hematoma 1 7.1 no 11 78.6 Titanium asymmetry, diplopia 1 4.5 exposure 2 9.1 hematoma 1 4.5 infection, rejection 2 9.1 no 17 77.3 The initial post-hoc power analysis, based on an assumed effect size of f = 0.35, indicated that the available sample size (n = 52) was sufficient to detect medium-to-large differences in complication rates among the implant groups at 80% power and α = 0.05. However, the actual observed complication rates were similar across materials – 22.2% for PEEK, 22.7% for titanium, and comparable frequencies for PMMA and silicone – indicating that the true effect size may be smaller than anticipated. Given these findings, additional power calculations were conducted using more conservative effect sizes. When assuming f = 0.25 or lower, the current sample size was found to be underpowered to detect small-to-moderate differences. This limitation suggests a reduced likelihood of identifying statistically relevant variations exist, particularly given the uneven distribution of cases across the four material groups. Therefore, non-significant results in the comparison of complication rates should be interpreted with caution. The possibility of a type II error due to insufficient power especially in detecting subtle differences cannot be excluded. These constraints highlight the need for larger, more evenly distributed samples in future research to confirm or refute observed trends. 3.3 Aesthetical outcomes Patient satisfaction with craniofacial reconstruction was assessed through an online survey covering five key aspects: aesthetic outcomes, symmetry, surgical site appearance, implant integration, and overall recommendation. The responses revealed significant differences between the four materials studied - PEEK, PMMA, silicone, and titanium which are shown in Appendix C. For aesthetic outcomes, PEEK implants achieved the highest ratings, with 66.7% of patients marking their satisfaction as “Highly satisfied” and 33.3% as “Harmonic”, indicating a consistently positive response. PMMA had mixed results, with 16.7% of patients “Highly satisfied”, 16.7% “Harmonic”, and 50% “As requested”. Silicone showed more variable results, with 42.9% rating as “Satisfied” or “As requested”, but only 7.1% achieving “Harmonic”. Titanium exhibited a wider range, with 43.5% marking “Harmonic” and 17.4% “Highly satisfied”, but also 17.4% rating as “Unsatisfied”, reflecting some dissatisfaction with its aesthetic outcomes. For symmetry, PEEK implants again led with 55.6% of patients rating “Highly satisfied”, 33.3% “Harmonic”, and 11.1% “Perfect”, showcasing excellent outcomes in this category. PMMA implants showed 66.7% “Harmonic”, 16.7% “Highly satisfied”, and 16.7% “Agreed”, indicating moderate success. Silicone results were split, with 42.9% rating as “Satisfied”, 28.6% “Harmonic”, and 14.3% “As requested”. Titanium showed strong results, with 39.1% “Highly satisfied”, 30.4% “Harmonic”, but also 8.7% “Unsatisfied”, reflecting variability in outcomes. Regarding surgical site appearance, including scar visibility and contour, PEEK performed well, with 55.6% “Highly satisfied”, 33.3% “Harmonic”, and 11.1% “Perfect”. PMMA implants were also favourable, with 66.7% “Harmonic”, 16.7% “Highly satisfied”, and 16.7% “Satisfied”. Silicone was moderately rated, with 28.6% each for “Harmonic” and “As requested”, and 21.4% “Highly satisfied” or “Satisfied”. Titanium implants had 34.8% “Highly satisfied”, 21.7% “Harmonic”, 13% “Perfect”, but 4.3% “Unsatisfied”. For implant integration with natural facial structure, PEEK achieved exceptional results, with 77.8% “Highly satisfied” and 22.2% “Perfect”, indicating complete patient approval. PMMA showed 66.7% “Harmonic”, 16.7% “Highly satisfied”, and 16.7% “Agreed”. Silicone had mixed feedback, with 42.9% rating as “Satisfied” and “As requested”, and 14.3% as “Harmonic”. Titanium was more varied, with 39.1% “Highly satisfied”, 21.7% “Harmonic”, and 8.7% “Unsatisfied”. Average ANA scores of patient satisfaction with craniofacial reconstruction presented in Fig. 4 . Finally, for recommendations, 100% of PEEK patients would recommend the material, compared to 83.3% for PMMA, 71.4% for silicone, and 73.9% for titanium. In summary, PEEK consistently outperformed the other materials across all categories, achieving the highest satisfaction ratings for aesthetics, symmetry, site appearance, and implant integration, coupled with universal patient recommendations. PEEK implants resulted in a mean ANA score of 8.86 (SD = 0.35; 8.25–9.25). Furthermore, the Kruskal-Wallis test revealed a statistically significant difference (H = 16.7605, df = 3, p = 0.000792). 4. Discussion The presented study examined several commonly used implant materials - PEEK, titanium, PMMA, and silicone in craniomaxillofacial reconstruction. This discussion synthesizes the findings with complications reported in other studies, providing a comparative perspective. The gathered data demonstrated the advantages of PEEK implants, including superior mechanical properties, aesthetic outcomes, and patient satisfaction. In our cohort of 52 cases, PEEK showed minimal complications, with only two hematoma cases. Patient satisfaction was high, with 77.8% rating implant integration as “highly satisfied” and 100% recommending it. Comparatively, Ha et al. ( 81 ) reported complications in 17.2% of their 29 cases with PEEK and titanium implants alloy, including screw loosening, dissatisfaction, and postoperative infections. Nguyen et al. (2018) documented a 4.4% infection rate in PEEK reconstructions among 136 cases. Li et al. ( 81 ) documented implant exposure in one patient (16.7%) among six patients after 10 months, while Ahmad et al. ( 81 ) observed implant removal due to recurrent infection in one case (10%) out of 10 patients. Anabtawi et al. (2021) identified complications in three cases (30%) among 10 patients, including recurrent oedema, bilateral mental nerve paraesthesia, and recurrent sinusitis. Alonso-Rodriguez et al. (2015) reported infections in two cases (14.3%) among 14 patients, with one requiring implant removal. Similarly, Kim et al. (2009) noted dehiscence in one patient (25%) among four with complex defects, and O’Reilly et al. (2015) described complications among 19 patients, including two cases of MRSA wound infections, one case of traumatic exposure, one poor cosmetic outcome, and one case of epidural fluid collection. Despite these reported complications, the rates remain relatively low and are often case-specific. These findings reinforce PEEK’s reputation as a reliable material with consistent clinical and aesthetic outcomes. However, the bio-inert nature of PEEK and occasional postoperative challenges (e.g., infection or exposure) highlight the need for further innovations in surface modifications to enhance osteoconductivity and reduce infection risks. Titanium implants had a complication rate of 22.7%, including infection, hematoma, and implant exposure. Patient satisfaction was varied, with 39.1% highly satisfied but 8.7% unsatisfied. Düzgün et al. (2020) observed similar trends in their 62 orbital reconstruction cases, reporting complications such as infection (1.6%), permanent diplopia (1.6%), and enophthalmos (1.6%). Chen et al. (2015) highlighted delayed healing in 28.6% of cases, particularly in diabetic patients. Nguyen et al. (2018) reported one infection and one case of dehiscence in titanium implants. These data underscore titanium’s utility in load bearing but its limitations in aesthetics outcomes. On the other hand, PMMA implants achieved a moderate satisfaction rate (66.7% rated symmetry as “harmonic”) but faced complications in 16.7% of cases, including implant extrusion. These align with Schön et al. (2021), who reported a 43.8% complication rate in 16 skull defect cases, including extra-axial hematomas (37.5%). Ming-Chi Hsieh et al. (2020) documented a 13.3% complication rate in occipital augmentation with PMMA implants, and Desai et al. (2019) noted a 13.3% infection rate in 30 cranioplasty cases. Our results align with these studies, highlighting its limitations in load-bearing regions and susceptibility to infection and extrusion. Finally, silicone had a complication rate of 21.4%, including asymmetry, extrusion, and patient dissatisfaction (rated appearance as “harmonic”). Al-Jandan et al. (2018) reported a 4.3% infection rate and a 13.8% displacement rate in 58 mandibular augmentation cases. Similarly, Kook et al. (2023) and Pelle-Ceravolo et al. ( 81 ) identified frequent complications, including infections, resorption, and implant displacement. These findings mirror the results from this study, confirming the high rates of revision and mixed aesthetic outcomes associated with silicone. PEEK demonstrates promising outcomes as an implant material, particularly in aesthetics and patient satisfaction. However, further comparative studies with longer follow-up are warranted to confirm its superiority over other materials. Despite promising findings, the claim of PEEK’s superiority must be interpreted with caution due to higher cost, limited global availability, and lack of long-term multicentric studies. Complications associated with PEEK implants appear to vary depending on the anatomical site of reconstruction. In current study, the two cases of hematoma associated with PEEK occurred in the frontal and parietal regions, where extensive subgaleal dissection and vascular plexus manipulation increase bleeding risk postoperatively. No complications were recorded in PEEK reconstruction involving the mandibular contour, zygoma, or infraorbital regions, which may reflect lower vascular density and more rigid tissue compartments. This suggests that complication profiles of PEEK implants are highly site-specific, emphasising the need for tailored surgical planning based on regional anatomy, soft tissue envelope, and vascularity. Optimising implant design to anatomical contours and ensuring adequate soft tissue coverage are critical to minimising complications in high-risks zones. In conclusion, while each material has specific advantages and limitations, PEEK offers the most balanced combination of mechanical properties, aesthetic outcomes, and patient satisfaction, with a lower risk of complications. Titanium remains effective for load-bearing applications but may require adjunctive measures to address aesthetic concerns. PMMA and silicone are best suited for selective cases but require caution due to their associated risks. These findings highlight the importance of personalised material selection in optimising reconstructive outcomes. Conclusion This study highlights the importance of material selection in craniomaxillofacial reconstruction to achieve optimal functional and aesthetic outcomes. PEEK emerged as the most promising material due to its superior patient satisfaction, low complication rates, and balanced mechanical and aesthetic properties. However, based on the findings and literature review, implant material selection in craniomaxillofacial reconstruction should be guided by anatomical location, functional load requirements, soft tissue coverage, patient comorbidities, and aesthetic expectations. PEEK implants are most suitable for moderate-load, aesthetically sensitive regions such as the zygoma, infraorbital rim, frontal bone, and mandibular angle, where its radiolucency and contouring precision are advatageous. Titanium remains effective for high-load-bearing areas, such as mandibular body and condyle, due to its strength and osseintegration capacity. Its use in aesthetic zones may be limited when soft tissue is thin, due to increased risk of exposure and palpability. PMMA is well-suited for cranial vault and frontal bone reconstruction, especially when economic constraints or availability limit other options. However, due to its exothermic curing and infection risk, it should be avoided in load-bearing areas or where soft tissue is limited. Silicone implants are appropriate for selective aesthetic augmentations, such as the chin and nasal dorsum, particularly when cost-effective options are needed, and soft tissue coverage is sufficient. Its use should be limited in areas with dynamic soft tissue movement or bone resorption risk. Incorporating these practical considerations into preoperative planning may optimise outcomes, minimise complications, and support patient-centered care. Abbreviations PEEK polyetheretherketone PMMA polymethylmethacrylate HA hydroxyapatite PICO The Population, Intervention, Comparison, Outcome PRISMA Preferred Items for Systematic Reviews and Meta-Analyses CAD/CAM Computer-aided design and manufacturing 3D three-dimensional CT computed tomography JBI Joanna Briggs Institute ROBINS-I Risk of Bias in Non-Randomised Studies of Interventions UK the United Kingdom NSAID nonsteroidal anti-inflammatory drug MRSA Methicillin-resistant Staphylococcus aureus ANA Aesthetic Numeric Analogue Declarations Ethics statement and consent statement The study protocol was approved by the Research Ethics Committee of the King’s College London (Ref. number LRS/DP-24/25-4531 from October 3, 2024). All procedures were conducted in accordance with the Declaration of Helsinki. Informed consent was obtained from all participants. All participants provided consent for the publication of anonymized data. Funding statement No funding was obtained. Author Contribution Manuscript Title: Polyetheretherketone for craniomaxillofacial defects: cases report, evaluation of patients’ satisfaction and a systematic literature reviewList of all Authors: Yuliya Menchisheva, Alvaro Varela Morillas, Nunzianda FrascioneCorresponding Author: Yuliya MenchishevaThis statement is to certify that all authors have seen and approved the manuscript being submitted, have contributed significantly to the work, attest to the validity and legitimacy of the data and its interpretation, and agree to its submission to the Maxillofacial Plastic and Reconstructive Surgery.Authors' contributionsY Menchisheva: Project development, Investigation, Methodology, Data collection, Data analysis, Manuscript writing and editing.AV Morillas: Project development, Visualization, Manuscript writing and editing.N Frascione: Supervision, Project development, Manuscript writing and editing.We the undersigned declare that this manuscript is original, has not been published before and is not currently being considered for publication elsewhere. We confirm that the manuscript has been read and approved by all named authors and that there are no other persons who satisfied the criteria for authorship but are not listed. We further confirm that the order of authors listed in the manuscript has been approved by all of us. We understand that the Corresponding Author is the sole contact for the Editorial process. She is responsible for communicating with the other authors about progress, submissions of revisions and final approval of proofs Signed by all authors as follows: Yuliya MenchishevaAlvaro Varela MorillasNunzianda Frascione Data Availability The datasets generated and analysed during the current study are availbale from the corresponding author upon reasonable request. Data sharing is subject to institutional and ethical regulations to protect participant confidentiality. References Gerbino G, Zavattero E, Zenga F, Bianchi FA, Garzino-Demo P, Berrone S (2015) Primary and secondary reconstruction of complex craniofacial defects using polyetheretherketone custom-made implants. J Craniomaxillofac Surg 43(8):1356–1363 Alasseri N, Alasraj A (2020) Patient-specific implants for maxillofacial defects: challenges and solutions. Maxillofac Plast Reconstr Surg 42(1):15 Kumar BP, Venkatesh V, Kumar KA, Yadav BY, Mohan SR (2016) Mandibular Reconstruction: Overview. J Maxillofac Oral Surg 15(4):425–441 Panayotov IV, Orti V, Cuisinier F, Yachouh J (2016) Polyetheretherketone (PEEK) for medical applications. J Mater Sci Mater Med 27(7):118 Jessop ZM, Hague A, Dobbs TD, Stewart KJ, Whitaker IS (2021) Facial Cartilaginous Reconstruction-A Historical Perspective, State-of-the-Art, and Future Directions. Front Surg 8:680186 Moharil S, Reche A, Durge K (2023) Polyetheretherketone (PEEK) as a Biomaterial: An Overview. Cureus 15(8):e44307 Li Y, Li Z, Tian L, Li D, Lu B, Shi C et al (2022) Clinical application of 3D-printed PEEK implants for repairing mandibular defects. J Craniomaxillofac Surg 50(8):621–626 Nocini R, D'Agostino A, Trevisiol L, Favero V (2022) Mandibular recontouring with polyetheretherketone (PEEK) patient-specific implants. BMJ Case Rep. ;15(4) Ahmad AF, Yaakob H, Khalil A, Georges P (2022) Evaluating patients' satisfaction level after using 3D printed PEEK facial implants in repairing maxillofacial deformities. Ann Med Surg (Lond) 79:104095 Alonso-Rodriguez E, Cebrián JL, Nieto MJ, Del Castillo JL, Hernández-Godoy J, Burgueño M (2015) Polyetheretherketone custom-made implants for craniofacial defects: Report of 14 cases and review of the literature. J Cranio-Maxillofacial Surg 43(7):1232–1238 Yan K, Wu Y, Xie Z, Yan S, Qiao C, Qu Y et al (2024) Endoscopic-Assisted Forehead Augmentation with Polyetheretherketone (PEEK) Patient-Specific Implant (PSI) for Aesthetic Considerations. Aesthetic Plast Surg 48(10):1889–1898 Narciso R, Basile E, Bottini DJ, Cervelli V (2021) PEEK Implants: An Innovative Solution for Facial Aesthetic Surgery. Case Rep Surg 2021:5518433 Kauke-Navarro M, Knoedler L, Knoedler S, Deniz C, Stucki L, Safi AF (2024) Balancing beauty and science: a review of facial implant materials in craniofacial surgery. Front Surg 11:1348140 Anabtawi M, Thomas M, Lee NJ (2021) The Use of Interlocking Polyetheretherketone (PEEK) Patient-Specific Facial Implants in the Treatment of Facial Deformities. A Retrospective Review of Ten Patients. J Oral Maxillofac Surg 79(5):1145. .e1-.e9 Kim MM, Boahene KD, Byrne PJ (2009) Use of customized polyetheretherketone (PEEK) implants in the reconstruction of complex maxillofacial defects. Arch Facial Plast Surg 11(1):53–57 Atef M, Mounir M, Shawky M, Mounir S, Gibaly A (2022) Polyetheretherketone patient-specific implants (PPSI) for the reconstruction of two different mandibular contour deformities. Oral Maxillofac Surg 26(2):299–309 Habib LA, Yoon MK (2021) Patient specific implants in orbital reconstruction: A pilot study. Am J Ophthalmol Case Rep 24:101222 Jalbert F, Boetto S, Nadon F, Lauwers F, Schmidt E, Lopez R (2014) One-step primary reconstruction for complex craniofacial resection with PEEK custom-made implants. J Craniomaxillofac Surg 42(2):141–148 Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD et al (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372:n71 Haddaway NR, Page MJ, Pritchard CC, McGuinness LA (2022) PRISMA2020: An R package and Shiny app for producing PRISMA 2020-compliant flow diagrams, with interactivity for optimised digital transparency and Open Synthesis. Campbell Syst Rev 18(2):e1230 de Vet HCW, Dikmans RE, Eekhout I (2017) Specific agreement on dichotomous outcomes can be calculated for more than two raters. J Clin Epidemiol 83:85–89 Sarfraz S, Mäntynen PH, Laurila M, Rossi S, Leikola J, Kaakinen M et al (2022) Comparison of Titanium and PEEK Medical Plastic Implant Materials for Their Bacterial Biofilm Formation Properties. Polym (Basel). ;14(18) Meyer H, Khalid SI, Dorafshar AH, Byrne RW (2021) The Materials Utilized in Cranial Reconstruction: Past, Current, and Future. Plast Surg (Oakv) 29(3):184–196 Pan Z, Patil PM (2014) Titanium osteosynthesis hardware in maxillofacial trauma surgery: to remove or remain? A retrospective study. Eur J Trauma Emerg Surg 40(5):587–591 Quatela VC, Chow J (2008) Synthetic facial implants. Facial Plast Surg Clin North Am 16(1):1–10 Faot F, Nascimento GG, Bielemann AM, Campão TD, Leite FR, Quirynen M (2015) Can peri-implant crevicular fluid assist in the diagnosis of peri-implantitis? A systematic review and meta-analysis. J Periodontol 86(5):631–645 Pietzka S, Wenzel M, Winter K, Wilde F, Schramm A, Ebeling M et al (2023) Comparison of Anatomical Preformed Titanium Implants and Patient-Specific CAD/CAM Implants in the Primary Reconstruction of Isolated Orbital Fractures-A Retrospective Study. J Pers Med. ;13(5) Rotaru H, Schumacher R, Kim S-G, Dinu C (2015) Selective laser melted titanium implants: a new technique for the reconstruction of extensive zygomatic complex defects. Maxillofacial Plast Reconstr Surg 37(1):1 Li J, Li P, Lu H, Shen L, Tian W, Long J et al (2013) Digital design and individually fabricated titanium implants for the reconstruction of traumatic zygomatico-orbital defects. J Craniofac Surg 24(2):363–368 Chattopadhyay C (2019) Reconstruction of Acquired Frontal Bone Defects Using Titanium Mesh Implants: A Retrospective Study. J Maxillofac Oral Surg 18(1):34–39 àWengen DF (2022) Titanium Implants in the Nose: State of the Art. Facial Plast Surg 38(5):461–467 Al-Sukhun J (2023) A Novel Method to Reconstruct the Upper and Lower Jaws Using 3D-Custom-Made Titanium Implants. J Craniofac Surg 34(3):e244–e6 Lim H-K, Choi Y-J, Choi W-C, Song I-S, Lee U-L (2022) Reconstruction of maxillofacial bone defects using patient-specific long-lasting titanium implants. Sci Rep 12(1):7538 Mounir M, Abou-ElFetouh A, ElBeialy W, Mounir R (2020) Patient-specific alloplastic endoprosthesis for reconstruction of the mandible following segmental resection: A case series. J Craniomaxillofac Surg 48(8):719–723 Woo JM, Baek SH, Kim JC, Choi JY (2018) Contour Restoration of Over-Resected Mandibular Angle and Lower Border by Reduction Mandibuloplasty Using Three-Dimensional Planning and Computer-Aided Design and Manufacturing Custom-Made Titanium Implants. J Craniofac Surg 29(4):e340–e3 Basketter DA, Whittle E, Monk B (2000) Possible allergy to complex titanium salt. Contact Dermat 42(5):310–311 Pigatto PD, Guastella C, Guzzi G (2017) Titanium Exposure Outcome in Facial Plastic and Reconstructive Surgery. Plast Reconstr Surg. ;139(1) Poli PP, de Miranda FV, Polo TOB, Santiago Júnior JF, Lima Neto TJ, Rios BR et al (2021) Titanium Allergy Caused by Dental Implants: A Systematic Literature Review and Case Report. Mater (Basel). ;14(18) Gafar Ahmed M, AlHammad ZA, Al-Jandan B, Almohammadi T, Khursheed Alam M, Bagde H (2023) Silicone Facial Implants, to Fixate or Not to Fixate: A Narrative Review. Cureus 15(2):e34524 Rojas YA, Sinnott C, Colasante C, Samas J, Reish RG (2018) Facial Implants: Controversies and Criticism. A Comprehensive Review of the Current Literature. Plast Reconstr Surg 142(4):991–999 Al-Jandan B, Marei HF (2018) Mandibular angle augmentation using solid silicone implants. Dent Med Probl 55(4):367–370 Rubin JP, Yaremchuk MJ (1997) Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature. Plast Reconstr Surg 100(5):1336–1353 Kook WS, Ryu DH, Baek W, Kook HM, Jang YY, Lew DH (2023) Prevention and Resolution of Silicone Implant-Related Problems in Secondary Rhinoplasty Using a Cross-Linked Human Acellular Dermal Matrix. Plast Reconstr Surg 152(1):45–54 Slupchynskyj O, Rahimi M (2014) Revision rhinoplasty in ethnic patients: pollybeak deformity and persistent bulbous tip. Facial Plast Surg 30(4):477–484 Pelle-Ceravolo M, Angelini M (2022) Zygomatic Implants through a Face-Lift Approach: Analysis of 30 Years' Experience. Plast Reconstr Surg 150(5):995–1005 Gosau M, Schiel S, Draenert GF, Ihrler S, Mast G, Ehrenfeld M (2006) [Craniofacial augmentation with porous polyethylene implants (Medpor: first clinical results]. Mund Kiefer Gesichtschir 10(3):178–184 Niechajev I (2012) Facial reconstruction using porous high-density polyethylene (medpor): long-term results. Aesthetic Plast Surg 36(4):917–927 Griffin M, Kalaskar D, Butler P (2019) Argon plasma modified nanocomposite polyurethane scaffolds provide an alternative strategy for cartilage tissue engineering. J Nanobiotechnol 17(1):51 Ku PKM, Vlantis AC, Tong MC, Chan TTT, Yeung ZWC, Cho RHW et al (2024) A Hybrid Auricular Framework of Autologous Rib Cartilage and a Porous Polyethylene Implant for Reconstruction of Congenital Microtia: A Modification of Nagata's Technique. Facial Plast Surg Aesthet Med 26(1):15–22 Scopelliti D, Amodeo G (2016) Nasal Dorsum Reconstruction With Alloplastic Material. J Craniofac Surg 27(7):e676–e8 Park JH, Kim JW, Kim SJ (2016) Midfacial Soft-Tissue Changes after Paranasal Augmentation with Porous Polyethylene. Facial Plast Surg 32(2):232–237 Groth MJ, Bhatnagar A, Clearihue WJ, Goldberg RA, Douglas RS (2006) Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects. Arch Facial Plast Surg 8(6):381–389 Ghosh S, Pramanick D, Ray A, Burman R, Saha A (2017) Fronto-orbital reconstruction using polymethyl methacrylate implant. Natl J Maxillofac Surg 8(2):153–156 Martinez-Seijas P, Díaz-Galvis LA, Hernando J, Leizaola-Cardesa IO, Aguilar-Salvatierra A, Gómez-Moreno G (2018) Polymethyl Methacrylate Custom-Made Prosthesis: A Novel Three-Dimension Printing-Aided Fabrication Technique for Cranial and/or Orbital Reconstruction. J Craniofac Surg 29(5):e438–e40 Schön SN, Skalicky N, Sharma N, Zumofen DW, Thieringer FM (2021) 3D-Printer-Assisted Patient-Specific Polymethyl Methacrylate Cranioplasty: A Case Series of 16 Consecutive Patients. World Neurosurg 148:e356–e62 Bruens ML, Pieterman H, de Wijn JR, Vaandrager JM (2003) Porous polymethylmethacrylate as bone substitute in the craniofacial area. J Craniofac Surg 14(1):63–68 Jain R, Mahendru S, Aggarwal A, Brajesh V, Aulakh HS, Singh S et al (2021) Feasibility of Customised Polymethyl Methacrylate Implants Fabricated Using 3D Printed Flexible Moulds for Correction of Facial Skeletal Deformities. J Craniofac Surg 32(6):1981–1985 Fernandes da Silva AL, Borba AM, Simão NR, Pedro FL, Borges AH, Miloro M (2014) Customized polymethyl methacrylate implants for the reconstruction of craniofacial osseous defects. Case Rep Surg 2014:358569 Aldabib J (2020) Reinforcement of poly (methyl methacrylate) denture base material. Dent Med Journal-Review 2(2):46–53 Thayaparan GK, Lewis PM, Thompson RG, D'Urso PS (2021) Patient-specific implants for craniomaxillofacial surgery: A manufacturer's experience. Ann Med Surg (Lond) 66:102420 Hsieh TY, Dhir K, Binder WJ, Hilger PA (2021) Alloplastic Facial Implants. Facial Plast Surg 37(6):741–750 Oliver JD, Eells AC, Saba ES, Boczar D, Restrepo DJ, Huayllani MT et al (2019) Alloplastic Facial Implants: A Systematic Review and Meta-Analysis on Outcomes and Uses in Aesthetic and Reconstructive Plastic Surgery. Aesthetic Plast Surg 43(3):625–636 Leão RS, Maior JRS, Lemos CAA, Vasconcelos B, Montes M, Pellizzer EP et al (2018) Complications with PMMA compared with other materials used in cranioplasty: a systematic review and meta-analysis. Braz Oral Res 32:e31 Kattimani VS, Chakravarthi PS, Prasad LK (2016) Biograft Block Hydroxyapatite: A Ray of Hope in the Reconstruction of Maxillofacial Defects. J Craniofac Surg 27(1):247–252 Systermans S, Cobraiville E, Camby S, Meyer C, Louvrier A, Lie SA et al (2024) An innovative 3D hydroxyapatite patient-specific implant for maxillofacial bone reconstruction: A case series of 13 patients. J Craniomaxillofac Surg 52(4):420–431 Brie J, Chartier T, Chaput C, Delage C, Pradeau B, Caire F et al (2013) A new custom made bioceramic implant for the repair of large and complex craniofacial bone defects. J Craniomaxillofac Surg 41(5):403–407 Staffa G, Barbanera A, Faiola A, Fricia M, Limoni P, Mottaran R et al (2012) Custom made bioceramic implants in complex and large cranial reconstruction: a two-year follow-up. J Craniomaxillofac Surg 40(3):e65–70 Huggins RJ, Mendelson BC (2016) Biologic Behavior of Hydroxyapatite Used in Facial Augmentation. Aesthetic Plast Surg 41(1):179–184 Siddiqui HA, Pickering KL, Mucalo MR (2018) A Review on the Use of Hydroxyapatite-Carbonaceous Structure Composites in Bone Replacement Materials for Strengthening Purposes. Mater (Basel). ;11(10) Zhang L, Shen S, Yu H, Shen SG, Wang X (2015) Computer-Aided Design and Computer-Aided Manufacturing Hydroxyapatite/Epoxide Acrylate Maleic Compound Construction for Craniomaxillofacial Bone Defects. J Craniofac Surg 26(5):1477–1481 Bawn C (1987) Encyclopedia of polymer science and engineering. Polymer 28(7):1234 Nigam M, Kotha V, Weinzweig J, Baker SB (2022) 30 - Aesthetic cranioplasty. In: Baker SB, Patel PK, Weinzweig J (eds) Aesthetic Surgery of the Facial Skeleton. Elsevier, London, pp 299–310 Ma R, Tang T (2014) Current strategies to improve the bioactivity of PEEK. Int J Mol Sci 15(4):5426–5445 Long J, Zhang J, Kang J, Fan Y, Zhang Z, Shi J et al (2023) Customed 3D-printed Polyetheretherketone (PEEK) Implant for Secondary Salvage Reconstruction of Mandibular Defects: Case Report and Literature Review. J Craniofac Surg 34(8):2460–2463 Nieminen T, Kallela I, Wuolijoki E, Kainulainen H, Hiidenheimo I, Rantala I (2008) Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow‐up. J Biomedical Mater Res Part A 84(2):377–383 Lommen J, Schorn L, Sproll C, Haussmann J, Kübler NR, Budach W et al (2022) Reduction of CT Artifacts Using Polyetheretherketone (PEEK), Polyetherketoneketone (PEKK), Polyphenylsulfone (PPSU), and Polyethylene (PE) Reconstruction Plates in Oral Oncology. J Oral Maxillofac Surg 80(7):1272–1283 Shah AM, Jung H, Skirboll S (2014) Materials used in cranioplasty: a history and analysis. NeuroSurg Focus 36(4):E19 Chen J, Xiao J, Han X, Sima X, Guo W (2023) An HA/PEEK scaffold with modified crystallinity via 3D-bioprinting for multiple applications in hard tissue engineering. Biomed Mater. ;18(6) Yu D, Lei X, Zhu H (2022) Modification of polyetheretherketone (PEEK) physical features to improve osteointegration. J Zhejiang Univ Sci B 23(3):189–203 Dondani JR, Iyer J, Tran SD (2023) Surface Treatments of PEEK for Osseointegration to Bone. Biomolecules. ;13(3) WHO Classification of Tumours Editorial Board. Head and neck tumours. Lyon (France): International Agency for Research on Cancer (2022) (WHO classification of tumours series te Additional Declarations No competing interests reported. Supplementary Files AppendixAnew.docx AppendixB.docx AppendixC.docx Cite Share Download PDF Status: Published Journal Publication published 24 Oct, 2025 Read the published version in Maxillofacial Plastic and Reconstructive Surgery → Version 1 posted Editorial decision: Revision requested 18 Aug, 2025 Reviews received at journal 18 Aug, 2025 Reviews received at journal 18 Aug, 2025 Reviews received at journal 10 Aug, 2025 Reviewers agreed at journal 09 Aug, 2025 Reviewers agreed at journal 08 Aug, 2025 Reviewers agreed at journal 08 Aug, 2025 Reviewers invited by journal 07 Aug, 2025 Editor assigned by journal 07 Aug, 2025 Submission checks completed at journal 07 Aug, 2025 First submitted to journal 04 Aug, 2025 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-7289687","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Research Article","associatedPublications":[],"authors":[{"id":498395893,"identity":"ac7b9032-2679-46fc-830c-38b7519e7c85","order_by":0,"name":"Yuliya Menchisheva","email":"data:image/png;base64,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","orcid":"","institution":"King's College London","correspondingAuthor":true,"prefix":"","firstName":"Yuliya","middleName":"","lastName":"Menchisheva","suffix":""},{"id":498395894,"identity":"86edcd66-6937-4279-a1e1-4b67007cb93f","order_by":1,"name":"Alvaro Varela Morillas","email":"","orcid":"","institution":"King's College London","correspondingAuthor":false,"prefix":"","firstName":"Alvaro","middleName":"Varela","lastName":"Morillas","suffix":""},{"id":498395895,"identity":"d0b8c1bb-0073-4752-a034-a08fe2bee4b1","order_by":2,"name":"Nunzianda Frascione","email":"","orcid":"","institution":"King's College London","correspondingAuthor":false,"prefix":"","firstName":"Nunzianda","middleName":"","lastName":"Frascione","suffix":""}],"badges":[],"createdAt":"2025-08-04 09:53:42","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-7289687/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-7289687/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1186/s40902-025-00482-9","type":"published","date":"2025-10-24T16:16:31+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":89229353,"identity":"e5b80962-f8a7-49b5-bd75-266ac59c6107","added_by":"auto","created_at":"2025-08-17 14:05:51","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":24628,"visible":true,"origin":"","legend":"\u003cp\u003eAesthetic Numeric Analogue scale. Created with BioRender.com\u003c/p\u003e","description":"","filename":"Figure1.png","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/a9cea60f0847b90c04461eee.png"},{"id":89229343,"identity":"ca493870-d295-47a8-9f5f-5cde1a672a67","added_by":"auto","created_at":"2025-08-17 14:05:50","extension":"jpg","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":394158,"visible":true,"origin":"","legend":"\u003cp\u003eThe PRISMA flow chart. Created with Github.com\u003c/p\u003e","description":"","filename":"Figure2.jpg","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/dc039eb595c1601b0e509069.jpg"},{"id":89229350,"identity":"9670ba6a-d098-4d0b-8fcc-820da18c7530","added_by":"auto","created_at":"2025-08-17 14:05:51","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":1066568,"visible":true,"origin":"","legend":"\u003cp\u003eBreakdown of research sample by facial implant location and complications in A) HA B) Silicone C) Polyethylene D) PMMA E) Titanium F) PEEK implant materials. Created with BioRender.com\u003c/p\u003e","description":"","filename":"3.png","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/5a7f740ca8e94b844f405fab.png"},{"id":89229357,"identity":"28d6f2b4-f5ba-4dcc-a89f-898f5aae52cc","added_by":"auto","created_at":"2025-08-17 14:05:51","extension":"png","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":84282,"visible":true,"origin":"","legend":"\u003cp\u003eANA scores of patient satisfaction with craniofacial reconstruction (presented as mean, minimum and maximum values). Created with BioRender.com\u003c/p\u003e","description":"","filename":"Figure4.png","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/5e88bf740e94662a1d71ede8.png"},{"id":94490318,"identity":"ae860b99-5c16-4265-8552-a2054c4e0533","added_by":"auto","created_at":"2025-10-27 17:09:08","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":2367178,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/c8215787-d458-4d62-81ce-00a3789ae96c.pdf"},{"id":89230281,"identity":"9e6163d0-c2c0-4503-ba72-6f666aeb670d","added_by":"auto","created_at":"2025-08-17 14:13:51","extension":"docx","order_by":1,"title":"","display":"","copyAsset":false,"role":"supplement","size":8729915,"visible":true,"origin":"","legend":"","description":"","filename":"AppendixAnew.docx","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/faad712a8cbb84bf1de68f9e.docx"},{"id":89229348,"identity":"c6f0c509-af5f-4a6b-a2b5-4a8118794270","added_by":"auto","created_at":"2025-08-17 14:05:51","extension":"docx","order_by":2,"title":"","display":"","copyAsset":false,"role":"supplement","size":51083,"visible":true,"origin":"","legend":"","description":"","filename":"AppendixB.docx","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/668de38d855dae8e9a2ff93f.docx"},{"id":89229365,"identity":"100016d7-400c-4511-95dc-9bc1aa06e3ee","added_by":"auto","created_at":"2025-08-17 14:05:51","extension":"docx","order_by":3,"title":"","display":"","copyAsset":false,"role":"supplement","size":17908,"visible":true,"origin":"","legend":"","description":"","filename":"AppendixC.docx","url":"https://assets-eu.researchsquare.com/files/rs-7289687/v1/1846c173f8ebc6d6e88dc01e.docx"}],"financialInterests":"No competing interests reported.","formattedTitle":"\u003cp\u003ePolyetheretherketone for Craniomaxillofacial Defects: Cases Report, Evaluation of Patients’ Satisfaction and a Systematic Literature Review\u003c/p\u003e","fulltext":[{"header":"1. Introduction","content":"\u003cp\u003eReconstruction of defects in the maxillofacial region poses an ongoing challenge for clinicians. Different biomaterials such as titanium, autologous bone grafts, and polymers are being used for facial defect reconstruction (\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e). However, for larger and more complex defects, physicians are still struggling to find optimal solutions that can improve clinical and aesthetic outcomes and ensure patient satisfaction with the treatment results (\u003cspan citationid=\"CR2\" class=\"CitationRef\"\u003e2\u003c/span\u003e).\u003c/p\u003e\u003cp\u003eFacial bone defects can cause facial deformities, impairments in chewing and speech, and have a profound impact on the physical and mental health of patients, seriously reducing their quality of life (\u003cspan citationid=\"CR3\" class=\"CitationRef\"\u003e3\u003c/span\u003e). These defects and deformities in maxillofacial area could be congenital or acquired, resulting from traumas, resection due to benign and malignant tumours, odontogenic and non-odontogenic infections as well as osteonecrosis.\u003c/p\u003e\u003cp\u003eThe main groups of alloplastic materials for facial plastic and reconstructive surgery include metals such as titanium, silicone, polymers like polyethylene, methylmethacrylate and polyetheretherketone (PEEK) and ceramics like hydroxyapatite (\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e). Depending on the intended use of an implant materials\u0026rsquo; (load-bearing or aesthetic region) the distinct qualities of the material should be carefully considered before their application (\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e).\u003c/p\u003e\u003cp\u003eRecent reports acknowledge that PEEK implants are an excellent treatment option and could effectively restore both bone and soft tissue deformities in facial surgery, meeting patients' desires and requirements for reconstructive or cosmetic purposes (\u003cspan additionalcitationids=\"CR7 CR8 CR9 CR10 CR11\" citationid=\"CR6\" class=\"CitationRef\"\u003e6\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR12\" class=\"CitationRef\"\u003e12\u003c/span\u003e).\u003c/p\u003e\u003cp\u003ePEEK is a polyaromatic semi-crystalline thermoplastic polymer which has all the mechanical properties suitable for bio-medical applications (\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e). It is a lasting material which is widely used in different fields of medicine especially for surgical purposes including oral and maxillofacial, orthopaedic, spine, plastic and reconstructive surgeries. Its benefits within the field of reconstructive surgery have been significantly supported by various studies (\u003cspan citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e, \u003cspan citationid=\"CR10\" class=\"CitationRef\"\u003e10\u003c/span\u003e, \u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e, \u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e). Over the past decade, there have been several reports on the utilization of PEEK material in maxillofacial reconstructive surgery. These reports are based on the analysis of sequential clinical cases (\u003cspan citationid=\"CR2\" class=\"CitationRef\"\u003e2\u003c/span\u003e, \u003cspan additionalcitationids=\"CR17\" citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e). However, further studies with larger cohorts and comparative analysis with alternative implant materials are needed to validate the accuracy of these findings.\u003c/p\u003e\u003cp\u003eThe purpose of this study was to perform a comprehensive systematic review of the literature and to conduct a retrospective review of clinical cases to evaluate the various materials utilized for craniomaxillofacial reconstruction, comparing their advantages, disadvantages, clinical applications, mechanical properties, aesthetical outcomes, and complications. Patient satisfaction with surgical outcomes was also evaluated in the long-term postoperative period through an online survey.\u003c/p\u003e\u003cp\u003eThe authors of this study hypothesize that PEEK implants offer superior clinical and aesthetical outcomes in craniomaxillofacial reconstruction compared to titanium, PMMA and silicone, due to its favourable mechanical properties and biocompatibility. Further, it is proposed that careful patient selection and implant material choice will optimize outcomes and patient satisfaction.\u003c/p\u003e\u003cp\u003eThe specific aims of this study were to: 1) systematically review the literature on materials used for craniomaxillofacial reconstruction, 2) compare the advantages and disadvantages of widely used implant materials based on clinical applications, mechanical properties, biocompatibility, aesthetic outcomes, and complications, 3) analyse a retrospective review of 52 cases of craniomaxillofacial reconstruction surgeries to share insights from past clinical experience, including surgical outcomes and complications, 4) evaluate patient satisfaction with surgical outcomes in the long-term postoperative period through an online survey.\u003c/p\u003e\u003cp\u003eThe findings from this study contribute to the growing body of evidence regarding material selection in craniomaxillofacial reconstruction. By combining a systematic review of the literature with clinical data and patient satisfaction surveys, this research provides a multifaceted evaluation of implant materials.\u003c/p\u003e"},{"header":"2. Material and methods","content":"\u003cp\u003eThe protocol for this study was registered in PROSPERO (ID: CRD420251079557,\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://www.crd.york.ac.uk/PROSPERO/view/CRD420251079557\u003c/span\u003e\u003cspan address=\"https://www.crd.york.ac.uk/PROSPERO/view/CRD420251079557\" targettype=\"URL\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e) and compiled by the Preferred Items for Systematic Reviews and Meta-Analyses (PRISMA) reporting guidelines.(\u003cspan citationid=\"CR19\" class=\"CitationRef\"\u003e19\u003c/span\u003e) The study selection process is illustrated using the PRISMA flow chart.(\u003cspan citationid=\"CR20\" class=\"CitationRef\"\u003e20\u003c/span\u003e) Supplemental materials have more details on the search methodology.\u003c/p\u003e\u003cdiv id=\"Sec3\" class=\"Section2\"\u003e\u003ch2\u003e2.1 Eligibility criteria\u003c/h2\u003e\u003cp\u003eSpecific inclusion and exclusion criteria to ensure the selection of relevant studies were established (Supplemental Table\u0026nbsp;1).\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec4\" class=\"Section2\"\u003e\u003ch2\u003e2.2 Search strategy\u003c/h2\u003e\u003cp\u003eThe Population, Intervention, Comparison, Outcome (PICO) framework was applied to ensure a structured and systematic approach to formulating the research question and guiding the literature search.\u003c/p\u003e\u003cp\u003e\u003cb\u003ePICO Framework\u003c/b\u003e:\u003c/p\u003e\u003cp\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u0026bull; Population (P): Patients with maxillofacial defects who underwent reconstructive surgery.\u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003e\u0026bull; Intervention (I): Use of PEEK implants for reconstruction.\u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003e\u0026bull; Comparison (C): Other implant materials such as titanium, polymethylmethacrylate (PMMA), silicone, polyethylene, hydroxyapatite.\u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003e\u0026bull; Outcome (O): clinical outcomes (implant success rates, complication rates), patient satisfaction, functional outcomes (improvement in chewing, speech, and overall quality of life).\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/p\u003e\u003cp\u003eA literature search for the review of facial implant materials in maxillofacial surgery was conducted through MEDLINE (PubMed), EMBASE and The Cochrane Library databases. All human studies published in the English language from the year 2000 onwards reporting on implants used in facial reconstruction were considered eligible for inclusion. The electronic search strategy was based on specific inclusion criteria, utilizing a combination of Medical Subject Headings (MeSH) and entry terms. The following search terms were applied: (\u0026ldquo;PEEK implants\u0026rdquo; OR \u0026ldquo;polyetheretherketone implants\u0026rdquo; OR \u0026ldquo;titanium implants\u0026rdquo; OR \u0026ldquo;PMMA implants\u0026rdquo; OR \u0026ldquo;silicone implants\u0026rdquo; OR \u0026ldquo;polyethylene implants\u0026rdquo; OR \u0026ldquo;hydroxyapatite implants\u0026rdquo;) AND (\u0026ldquo;maxillofacial reconstruction\u0026rdquo; OR \u0026ldquo;facial bone defects\u0026rdquo; OR \u0026ldquo;craniofacial reconstruction\u0026rdquo;) AND (\u0026ldquo;patient satisfaction\u0026rdquo; OR \u0026ldquo;clinical outcomes\u0026rdquo; OR \u0026ldquo;aesthetical outcomes\u0026rdquo; OR \u0026ldquo;complication\u0026rdquo; OR \u0026ldquo;functional outcomes\u0026rdquo;). According to the inclusion and exclusion criteria, the articles were chosen based on their titles and abstracts (Appendix A).\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec5\" class=\"Section2\"\u003e\u003ch2\u003e2.3 Selection process\u003c/h2\u003e\u003cp\u003eAll the studies retrieved were screened in two stages using Rayyan software for systematic review. First, two independent reviewers evaluated the titles and abstracts to determine relevance. Then, full texts of the selected studies were reviewed, and only those meeting the inclusion and exclusion criteria were considered eligible for analysis.\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec6\" class=\"Section2\"\u003e\u003ch2\u003e2.4 Data collection process\u003c/h2\u003e\u003cp\u003eEndNote, a reference management software, was used to streamline the data collection and organisation process. Duplicate articles were removed. The articles were selected by title and abstract for relevance according to the specified inclusion and exclusion criteria outlined below. All abstracts were independently reviewed. Any disagreements were resolved by the third author's involvement (AM)(\u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e). Google Scholar Alerts was used to update citations extended to 31st March 2025 in order to ensure the inclusion of the most recent and relevant publications.\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec7\" class=\"Section2\"\u003e\u003ch2\u003e2.5 Study risk of bias assessment\u003c/h2\u003e\u003cp\u003eThe risk of bias assessment was conducted using two validated tools based on study design. The Joanna Briggs Institute (JBI) critical appraisal checklist (Australia, JBI) was used for case reports and case series. For retrospective and prospective studies, the Risk of Bias in Non-Randomised Studies of Interventions (ROBINS-I) (UK, Cochrane) was applied to assess potential biases in studies.\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec8\" class=\"Section2\"\u003e\u003ch2\u003e2.6 Selection Criteria\u003c/h2\u003e\u003cp\u003e The inclusion and exclusion criteria for study eligibility were established in the study protocol. The current evaluation covered every kind of clinical investigation involving human participants, including controlled clinical trials, prospective and retrospective studies, case series, and case reports. On the other hand, review papers and experiments conducted in vitro or on animals were not included. The records where the titles and abstracts included the words \u0026ldquo;dental\u0026rdquo;, \u0026ldquo;prosthetic rehabilitation\u0026rdquo;, \u0026ldquo;use of injectable implants/fillers\u0026rdquo;, literature reviews without clinical cases, systematic reviews, meta-analysis, in-vitro studies and animal studies were excluded.\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec9\" class=\"Section2\"\u003e\u003ch2\u003e2.7 Retrospective study\u003c/h2\u003e\u003cp\u003eData from medical records of all 18\u0026ndash;74 years old patients who underwent maxillofacial reconstruction procedures using different implant materials such as PEEK, titanium, PMMA and silicone at Hospital 5 in Almaty, Kazakhstan, between 2021 and 2024 were collected. The informed consent for the use of patient data was obtained through an ethical process. The hospital administrator initially contacted eligible patients via phone, explaining the study\u0026rsquo;s purpose and requesting verbal consent for the retrospective analysis of existing medical records. The study protocol was approved by the Research Ethics Committee of King\u0026rsquo;s College London (Ref. number LRS/DP-24/25-4531 from October 3, 2024). Data such as age, sex, diagnosis, localization of the bone defect or deformity, cause of the bone defect or deformity, material of the implant that was used for reconstruction, type of reconstruction (primary or delayed), duration of operation in minutes, number of occupied bed days, postoperative complications, comorbidities, bad habits, presence of preoperative or postoperative radiotherapy or bisphosphonate medication were collected. All data were anonymised. Assessment of the incidence of complications, such as infection, hematoma, implant failure and others, following facial reconstructions using PEEK, titanium, PMMA and silicone implants was also provided.\u003c/p\u003e\u003cp\u003eSurgical technique: All surgeries were performed under general anaesthesia using standardised protocols by the same surgical team. Implant fit was pre-planned using CAD/CAM (Computer-aided design and manufacturing) design and patient-specific 3D models. All implants were customised and fabricated according to defect location and contour. PEEK implants were fixated using self-tapping titanium screws (1.5-2.0 mm), with bicortical engagement where possible, typically in 3\u0026ndash;4 quadrants. Titanium implants fixation followed standard osteosynthesis principles. PMMA implants were prefabricated preoperatively and sterilised using ethylene oxide. Implants were seated into the defect and secured with titanium screws to the surrounding bone. Silicone implants were preformed and positioned in subperiosteal pockets. Fixation was performed using titanium microscrews. Hemostasis was carefully achieved using bipolar cautery and absorbable hemostatic agents. In all xases, layered wound closure was performed with resorbable 3\u0026thinsp;\u0026minus;\u0026thinsp;0, 4\u0026thinsp;\u0026minus;\u0026thinsp;0 or 5\u0026thinsp;\u0026minus;\u0026thinsp;0 sutures. A closed-suction drain was placed where indicated and removed after 24\u0026ndash;48 hours.\u003c/p\u003e\u003cp\u003ePostoperative protocol: Postoperative care included antibiotics (ceftriaxone 1g IV for 5 days). Analgesia was administered via NSAIDs. Wound care involved sterile dressing changes every 24 hours until suture removal (at day 7\u0026ndash;10). Patients were monitored in the inpatient ward for an average6.13\u0026plusmn;0.23 days. All patients underwent standardised clinical follow-up at 1 week, 1 month, 3 months, and 12 months postoperatively. Complications were assessed during each follow-up period by the same clinical team using a uniform checklist.\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec10\" class=\"Section2\"\u003e\u003ch2\u003e2.8 Aesthetic outcomes\u003c/h2\u003e\u003cp\u003eThe study included an assessment of the aesthetic outcomes of patients who already underwent surgical procedures using different implant materials for maxillofacial defects and deformities at Hospital 5 in Almaty, Kazakhstan between the years 2021 and 2024.\u003c/p\u003e\u003cp\u003eThe survey was conducted anonymously using a structured questionnaire. The questionnaire was designed using the Google Forms application to assess the patient's satisfaction with the aesthetic outcome of their surgery. For the online survey, additional consent was obtained. All participants received the information sheet and consent form via WhatsApp. A series of questions rated on an eleven-point scale according to the \u0026ldquo;Aesthetic Numeric Analogue\u0026rdquo; (ANA) were included (Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e1\u003c/span\u003e). Patients were asked to select the word that best described their level of satisfaction with the aesthetic results of their reconstructive surgery.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe responses from the questionnaires were collected and coded numerically, with each descriptor assigned a specific score. The survey was conducted in accordance with the ethical standards of the committee responsible for human experimentation (institutional and national), and with the Helsinki Declaration of 1975, as revised in 2013 (\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttp://ethics.iit.edu/ecodes/node/3931\u003c/span\u003e\u003cspan address=\"http://ethics.iit.edu/ecodes/node/3931\" targettype=\"URL\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e). Written consent was obtained from all parents/legal guardians of participants enrolled in the study.\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec11\" class=\"Section2\"\u003e\u003ch2\u003e2.9 Statistical analysis\u003c/h2\u003e\u003cp\u003eDescriptive statistics summarised the patient characteristics and outcomes. Chi-square tests compared the complication rates, while the Kruskal-Wallis test was used to analyse aesthetic outcomes across the four implant materials (PEEK, titanium, PMMA, silicone).\u003c/p\u003e\u003cp\u003eTo evaluate the adequacy of the sample size for detecting differences in complication rates among the four implant material groups, a post-hoc power analysis was conducted using G*Power 3.1. software. The analysis assumed an effect size f\u0026thinsp;=\u0026thinsp;0.35 (medium-to-large), α\u0026thinsp;=\u0026thinsp;0.05, and power 1 - β\u0026thinsp;=\u0026thinsp;0.80. The observed effect sizes were computed and interpreted with corresponding 95% confidence intervals. Additionally, power calculations were repeated using smaller effect sizes (f\u0026thinsp;=\u0026thinsp;0.20\u0026ndash;0.25) to determine the minimum detectable differences under more conservative assumptions.\u003c/p\u003e\u003c/div\u003e"},{"header":"3. Results","content":"\u003cdiv id=\"Sec13\" class=\"Section2\"\u003e\u003ch2\u003e3.1 Systematic literature review\u003c/h2\u003e\u003cp\u003eThere were 3685 patients in 150 studies overall. There were 42 studies (with 821 patients) in the titanium group, 12 studies (with 806 patients) in the silicone group, 24 studies (with 914 patients) in the polyethylene group, 18 studies (with 382 patients) in the acrylic material - PMMA group, 41 studies (with 479 patients) in the PEEK group, 13 studies (with 283 patients) in the hydroxyapatite group. The PRISMA flow diagram is illustrated in Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e2\u003c/span\u003e.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cdiv id=\"Sec14\" class=\"Section3\"\u003e\u003ch2\u003e3.1.1 Titanium\u003c/h2\u003e\u003cp\u003eTitanium is widely used in reconstructive maxillofacial surgery, particularly for zygomatic-orbital defects, due to its high mechanical strength, corrosion resistance and biocompatibility (\u003cspan citationid=\"CR22\" class=\"CitationRef\"\u003e22\u003c/span\u003e). The main advantages of titanium implants are their durability, stability, rigidity and ability to provide osseointegration (\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e, \u003cspan citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e). However, titanium\u0026rsquo;s extreme rigidity limits its use in aesthetic augmentation. Its thermal sensitivity can result in an uncomfortable sensation of cold that frequently leads to removal due to the implant's higher heat conductivity than the surrounding tissues (\u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e). It also produces imaging artifacts and carries risks of implant rejection (\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e). Studies also highlighted the challenges in precise reconstruction with titanium (\u003cspan citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e). Pietzka et al. (\u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e) reported a 66.6% inaccuracy rate in orbital reconstructions using patient-specific titanium implants. In the zygomatic-orbital region, implant exposure has been observed due to thin overlying soft tissue, compromising cosmetic results (\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e), (\u003cspan additionalcitationids=\"CR29\" citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR30\" class=\"CitationRef\"\u003e30\u003c/span\u003e). Titanium nasal implants, introduced in 2003, aimed to improve airway patency (\u003cspan citationid=\"CR31\" class=\"CitationRef\"\u003e31\u003c/span\u003e). Titanium meshes and plates are often used for structural support in reconstructive surgery and to replicate maxillary or mandibular contours (\u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e, \u003cspan citationid=\"CR33\" class=\"CitationRef\"\u003e33\u003c/span\u003e). Mounir et al. (\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e) documented three failures out of seven cases using patient-specific titanium endoprostheses for mandibular reconstruction, due to mucosal dehiscence and fistula formation. In contrast, Woo et al. (\u003cspan citationid=\"CR35\" class=\"CitationRef\"\u003e35\u003c/span\u003e) demonstrated successful contour restoration of the mandibular angle and its lower border using titanium implants. Although titanium is corrosion-resistant, allergic reactions have been reported (\u003cspan citationid=\"CR36\" class=\"CitationRef\"\u003e36\u003c/span\u003e) (\u003cspan citationid=\"CR37\" class=\"CitationRef\"\u003e37\u003c/span\u003e) (\u003cspan citationid=\"CR38\" class=\"CitationRef\"\u003e38\u003c/span\u003e).\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec15\" class=\"Section3\"\u003e\u003ch2\u003e3.1.2 Silicone\u003c/h2\u003e\u003cp\u003eSilicone is widely used in facial skeleton implants especially for aesthetic purposes. Silicone implants can be premanufactured (i.e., malar, chin, mandibular implants) or a silicone block can be used, from which the surgeon cuts out the required sized implant. It is worth to acknowledge that this material has higher incidence of infections and displacements, depending on the implanted area (\u003cspan citationid=\"CR39\" class=\"CitationRef\"\u003e39\u003c/span\u003e). The chin and mandibular area are considered the safest, while malar implants have a high incidence of prominence (\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e). However, Al-Jandan et al. (\u003cspan citationid=\"CR41\" class=\"CitationRef\"\u003e41\u003c/span\u003e) reported cases of displacement of silicone implants in mandibular angle augmentation. According to a recent narrative review by Gafar Ahmed et al. (\u003cspan citationid=\"CR39\" class=\"CitationRef\"\u003e39\u003c/span\u003e) silicone implantation has a range of complications such as asymmetry, bone resorption or erosion, displacement, dissatisfaction, oedema, hematoma, infection, mucosal irritation, pain, and paraesthesia. Over time, the substance usually becomes encapsulated by a fibrous membrane and is not integrated into the host. This makes removal easier but needed due to seroma formation, extrusion, undesired implant displacement, and poor cosmetic results (\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e). In comparison to porous polyethylene and hydroxyapatite, silicone implants had one of the highest removal rates according to Rubin et al. (\u003cspan citationid=\"CR42\" class=\"CitationRef\"\u003e42\u003c/span\u003e) It is worth acknowledging that the use of silicone implants is popular among cases of augmentation rhinoplasty. Despite its benefits, using silicone implants can lead to negative outcomes, including contracture deformity, immediate and delayed infection, and an improper implant contour necessitating revision surgery (\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e). Poor implant location and selection may be the cause of most malformations. The replacement of existing grafts with specially carved silicone implants achieves the desired aesthetic results (\u003cspan citationid=\"CR44\" class=\"CitationRef\"\u003e44\u003c/span\u003e). The utilization of cheek silicone implants has proven to be an excellent technique for rejuvenating midfacial volume. The main challenge in this operation lies in choosing the right type, shape, and size of the silicone implant (\u003cspan citationid=\"CR45\" class=\"CitationRef\"\u003e45\u003c/span\u003e).\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec16\" class=\"Section3\"\u003e\u003ch2\u003e3.1.3 Polyethylene\u003c/h2\u003e\u003cp\u003eAs an alternative to bone grafts, polyethylene is a biocompatible, porous, high-density implant material. It is commonly used in aesthetic plastic surgery for contour enhancement in cases of rhinoplasty, chin, mandibular and malar augmentation. In addition, polyethylene is utilized in congenital malformations, closure of post-traumatic defects and reconstruction after tumour removal (\u003cspan citationid=\"CR46\" class=\"CitationRef\"\u003e46\u003c/span\u003e). Significant vascular and soft-tissue ingrowth is made possible by its porous nature. Soft tissue ingrowths, collagen deposition, and eventual vascularization were confirmed by biopsies in a recent study by Niechajev (\u003cspan citationid=\"CR47\" class=\"CitationRef\"\u003e47\u003c/span\u003e).\u003c/p\u003e\u003cp\u003eOne of the most popular applications in the use of polyethylene is auricular reconstruction for congenital malformations. The synthetic polyethylene material called Medpor is currently used to replace missing face cartilage, although it is not a suitable substitute for complex defects reconstruction due to its high rate of surgical complications, such as infection and extrusion (\u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e). Also, porous polyethylene implants are widely used with rib cartilage for microtia reconstruction. According to Ku et al. in their study 5 (15.2%) of 33 hybrid frameworks cases (polyethylene\u0026thinsp;+\u0026thinsp;rib) were removed due to infection or extrusion, which is considered as a high explantation rate (\u003cspan citationid=\"CR49\" class=\"CitationRef\"\u003e49\u003c/span\u003e). However, according to different recent research, nasal and paranasal augmentation using porous polyethylene is a dependable technique that causes the least amount of morbidity in patients with soft tissue insufficiency (\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e, \u003cspan citationid=\"CR51\" class=\"CitationRef\"\u003e51\u003c/span\u003e).\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec17\" class=\"Section3\"\u003e\u003ch2\u003e3.1.4 Polymethyl methacrylate\u003c/h2\u003e\u003cp\u003ePolymethyl methacrylate (PMMA) has been applied to numerous cases of orbital (\u003cspan citationid=\"CR52\" class=\"CitationRef\"\u003e52\u003c/span\u003e), fronto-orbital (\u003cspan citationid=\"CR53\" class=\"CitationRef\"\u003e53\u003c/span\u003e, \u003cspan citationid=\"CR54\" class=\"CitationRef\"\u003e54\u003c/span\u003e), zygomatic reconstruction and cranioplasty (\u003cspan citationid=\"CR55\" class=\"CitationRef\"\u003e55\u003c/span\u003e, \u003cspan citationid=\"CR56\" class=\"CitationRef\"\u003e56\u003c/span\u003e), midface and mandibular augmentation (\u003cspan citationid=\"CR57\" class=\"CitationRef\"\u003e57\u003c/span\u003e). PMMA is a biocompatible and nondegradable acrylic resin-based implant (\u003cspan citationid=\"CR58\" class=\"CitationRef\"\u003e58\u003c/span\u003e); and it also presents radiolucent properties, which makes it hard to detect in radiographs but benefits in ease post-operative imaging in the follow-up period (\u003cspan citationid=\"CR59\" class=\"CitationRef\"\u003e59\u003c/span\u003e). PPMA implants are encapsulated during the time with fibrous connective tissue. If pathology recurs and revision surgery is necessary, this guarantees a straightforward removal (\u003cspan citationid=\"CR60\" class=\"CitationRef\"\u003e60\u003c/span\u003e).\u003c/p\u003e\u003cp\u003eThe initial flexibility of the material can be attributed to the combination of the liquid polymer and the monomeric powder. Eventually, the substance undergoes an exothermic reaction and solidifies into a highly resilient material, achieving the desired shape (\u003cspan citationid=\"CR61\" class=\"CitationRef\"\u003e61\u003c/span\u003e). Bruens et al. (\u003cspan citationid=\"CR56\" class=\"CitationRef\"\u003e56\u003c/span\u003e) reported long-term results of using the porous form of PMMA in patients with craniofacial defects over 20 years. An aqueous, biodegradable carboxymethylcellulose gel was dispersed to create pores in implants. PMMA was prepared using the traditional bone cement composition of methylmethacrylate liquid and PMMA powder. The pores provided space for bone resorption improving prosthesis fixation. Jain et al. (\u003cspan citationid=\"CR57\" class=\"CitationRef\"\u003e57\u003c/span\u003e) believe that patient-specific PMMA implants have become the gold standard for reconstructing cranial abnormalities, with outstanding long-term outcomes. However, PMMA was shown to have a relative rate of hematoma formation and infection following implantation, according to a meta-analysis of facial implant materials (\u003cspan citationid=\"CR62\" class=\"CitationRef\"\u003e62\u003c/span\u003e). On the other hand, the meta-analysis conducted by Leao et al. (\u003cspan citationid=\"CR63\" class=\"CitationRef\"\u003e63\u003c/span\u003e) indicated that the use of PMMA yields complication rates near those of autologous bone and titanium mesh.\u003c/p\u003e\u003cp\u003ePMMA material is not usually used for midfacial augmentation or reconstruction, especially in load-bearing areas, because of the difficulty in reshaping it, the risk of infections and plate fractures, and the lack of osseointegration (\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e).\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec18\" class=\"Section3\"\u003e\u003ch2\u003e3.1.5 Bioceramics\u003c/h2\u003e\u003cp\u003eRecent studies have demonstrated that hydroxyapatite (HA) based implants outperform other alloplastic implants in terms of promoting cellular adhesion and integration (\u003cspan additionalcitationids=\"CR65 CR66\" citationid=\"CR64\" class=\"CitationRef\"\u003e64\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR67\" class=\"CitationRef\"\u003e67\u003c/span\u003e). HA plates are used for grafting facial bones, such as zygoma, maxilla and mandible. The remarkable bio-acceptance of HA for facial augmentation was confirmed by the authors' discovery that the HA granules are enveloped by host collagen and gradually replaced by neo-bone, including osteoblasts and osteocytes (\u003cspan citationid=\"CR68\" class=\"CitationRef\"\u003e68\u003c/span\u003e). Another main advantage of using HA implants is their biocompatibility. As HA is a naturally occurring mineral found in human bones, there is a lower risk of immune rejection or adverse reactions compared to other materials (\u003cspan citationid=\"CR65\" class=\"CitationRef\"\u003e65\u003c/span\u003e). This also means that the implant is less likely to cause inflammation or infection. However, it works well when used in the form of plates and meshes, while solid implants are significantly brittle. Researchers have reported that HA implants have a lower mechanical strength and toughness than titanium and PEEK implants, which make HA implants more prone to fracture or failure under mechanical stress, especially in load-bearing areas such as the mandible and maxilla (\u003cspan citationid=\"CR69\" class=\"CitationRef\"\u003e69\u003c/span\u003e). Zhang et al. (\u003cspan citationid=\"CR70\" class=\"CitationRef\"\u003e70\u003c/span\u003e) emphasised the lack of confidence on the optimal balance between strength and osseointegration.\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec19\" class=\"Section3\"\u003e\u003ch2\u003e3.1.6 Polyetheretherketone\u003c/h2\u003e\u003cp\u003eThe use of PEEK implants in maxillofacial reconstructive surgery has gained significant popularity in recent years due to its many advantages over other implant materials. Commercialized for industry in the 1980s (\u003cspan citationid=\"CR71\" class=\"CitationRef\"\u003e71\u003c/span\u003e), PEEK first described in cranioplasty by Hanasono et al. and has gained popularity since the early 2000s (\u003cspan citationid=\"CR72\" class=\"CitationRef\"\u003e72\u003c/span\u003e). According to Ma et al. (\u003cspan citationid=\"CR73\" class=\"CitationRef\"\u003e73\u003c/span\u003e), PEEK contains an aromatic molecular backbone and functional groups located between the acrylic rings that are a mix of ether and ketone.\u003c/p\u003e\u003cp\u003ePEEK has superior mechanical properties including high strength, stiffness, and toughness which make it an ideal material for load-bearing applications (\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e, \u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e, \u003cspan citationid=\"CR74\" class=\"CitationRef\"\u003e74\u003c/span\u003e). When compared to alternative alloplastic implant materials, PEEK offers a number of benefits. PEEK does not cause artifacts on radiographic imaging and exhibits radiographic translucency, greatly enhancing picture quality, making it easier to radiologically analyse the tissues surrounding the implant (\u003cspan citationid=\"CR75\" class=\"CitationRef\"\u003e75\u003c/span\u003e). This is advantageous for CT-based adjuvant radiation planning and radiological tumor follow-up (\u003cspan citationid=\"CR76\" class=\"CitationRef\"\u003e76\u003c/span\u003e). In addition, PEEK does not undergo exothermic reactions like methyl methacrylate and is neither allergic nor magnetic (\u003cspan citationid=\"CR77\" class=\"CitationRef\"\u003e77\u003c/span\u003e). Moreover, PEEK's flexibility is similar to that of cortical bone (\u003cspan citationid=\"CR73\" class=\"CitationRef\"\u003e73\u003c/span\u003e). However, PEEK's bio-inertia causes challenging osteogenesis and weak osteoconductive qualities (\u003cspan citationid=\"CR78\" class=\"CitationRef\"\u003e78\u003c/span\u003e). To improve its osteoinductive and antimicrobial capabilities, different types of functionalization of PEEK surfaces and changes in PEEK structure have been proposed by various authors (\u003cspan citationid=\"CR79\" class=\"CitationRef\"\u003e79\u003c/span\u003e, \u003cspan citationid=\"CR80\" class=\"CitationRef\"\u003e80\u003c/span\u003e). In contrast, PEEK implants are a relatively new material and have not been extensively studied in long-term clinical trials.\u003c/p\u003e\u003cp\u003eThe advantages and disadvantages of the six discussed implant materials used in reconstructive maxillofacial surgery are summarised in Table\u0026nbsp;\u003cspan refid=\"Tab1\" class=\"InternalRef\"\u003e1\u003c/span\u003e.\u003c/p\u003e\u003cp\u003e\u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab1\" border=\"1\"\u003e\u003ccaption language=\"En\"\u003e\u003cdiv class=\"CaptionNumber\"\u003eTable 1\u003c/div\u003e\u003cdiv class=\"CaptionContent\"\u003e\u003cp\u003eMain advantages and disadvantages of the most common materials for reconstructive surgery.\u003c/p\u003e\u003c/div\u003e\u003c/caption\u003e\u003ccolgroup cols=\"3\"\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e\u003cthead\u003e\u003ctr\u003e\u003cth align=\"left\" colname=\"c1\"\u003e\u003cp\u003eMaterial\u003c/p\u003e\u003c/th\u003e\u003cth align=\"left\" colname=\"c2\"\u003e\u003cp\u003eAdvantages\u003c/p\u003e\u003c/th\u003e\u003cth align=\"left\" colname=\"c3\"\u003e\u003cp\u003eDisadvantages\u003c/p\u003e\u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eTitanium\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eExcellent biocompatibility, corrosion resistance, high mechanical strength, osseointegration, not ferromagnetic, durable, stable, rigid.\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e\u003cp\u003eThermal sensitivity, not translucent - cause radiographic distorge, cosmetic issues, potential for allergic reactions (as a result lead to rejection).\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eSilicone\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eSuitable for aesthetic purposes, flexible, easy removal due to encapsulation.\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e\u003cp\u003eBone resorption, lack of osseointegration, high infection and displacement rates, high rate of asymmetry due to displacement, high removal rate, poor integration.\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003ePolyethylene\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eAllows tissue ingrowth,\u003c/p\u003e\u003cp\u003eavailability.\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e\u003cp\u003eThermal sensitivity, hard to remove, high risk of infection and extrusion, lack of rigidity (not ideal for load-bearing areas).\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003ePMMA\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eRadiolucent, customizable before polymerization, biocompatible, bone ingrowth in porous form implants, cost-effective.\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e\u003cp\u003eProvide exothermic reaction,\u003c/p\u003e\u003cp\u003edifficulty in reshaping after polymerization, lack of osseointegration (non-porous forms), high risk of infection (for porous implants), not load-bearing.\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eBioceramics (HА)\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003ePromotes cellular adhesion and osseointegration, excellent biocompatibility, osseoconductivity, replaced by newly formed bone, low immune rejection risk\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e\u003cp\u003eBrittle, low mechanical strength, prone to fracture, potential infection, less suitable for load-bearing areas.\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003ePEEK\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eHigh strength and stiffness,\u003c/p\u003e\u003cp\u003eradiolucent, non-magnetic,\u003c/p\u003e\u003cp\u003eresistant to gamma radiation, no thermal reactions and thermal sensitivity, low weight, similar flexibility to bone, steam sterilization.\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c3\"\u003e\u003cp\u003eBio-inert, requires surface modification, poor adhesion, incidence of infection, higher cost, limited long-term data.\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/colgroup\u003e\u003c/table\u003e\u003c/div\u003e\u003c/p\u003e\u003cp\u003eAnatomical areas of implementation and complications associated with different implant materials in craniomaxillofacial reconstruction were analysed and presented in Appendix B and Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e3\u003c/span\u003e. Among 3685 reconstruction cases reviewed, complication rates varied significantly across implant materials. PEEK demonstrated a complication rate of 13.4% (64/479) with the highest patient satisfaction. Titanium had a complication rate of 4.8% (39/821) and remained the preferred material for load-bearing regions, although it presented risks of exposure. PMMA showed an 11.04% (38/382) complication rate and proved effectiveness in cranial reconstructions but was associated with hematomas and dural tears. Polyethelene had the highest complication rate at 15.75% (144/914), with frequent infections and implant exposures. Silicone showed a 13.4% (108/806) complication rate, most commonly involving bone resorption and displacement. HA had a moderate complication rate of 9.5% (27/283), with infection being the primary issue.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eStatistical comparison using Pearson\u0026rsquo;s Chi-square test revealed a significant difference in complication rates across the six materials (p\u0026thinsp;\u0026lt;\u0026thinsp;0.01), underscoring the need for individualised implant selection. These findings highlight the importance of choosing implant materials based on anatomical location, functional demands, and complication profiles to optimise reconstructive outcomes and enhance patient satisfaction.\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv id=\"Sec20\" class=\"Section2\"\u003e\u003ch2\u003e3.2 Retrospective analysis\u003c/h2\u003e\u003cdiv id=\"Sec21\" class=\"Section3\"\u003e\u003ch2\u003e3.2.1 Patient characteristics\u003c/h2\u003e\u003cp\u003eThe study population comprised 22 females and 30 males with a mean age of 37.46\u0026thinsp;\u0026plusmn;\u0026thinsp;1.36 years and with an age range of 18\u0026ndash;67 years. The patient characteristics are presented in Table\u0026nbsp;\u003cspan refid=\"Tab2\" class=\"InternalRef\"\u003e2\u003c/span\u003e.\u003c/p\u003e\u003cp\u003e\u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab2\" border=\"1\"\u003e\u003ccaption language=\"En\"\u003e\u003cdiv class=\"CaptionNumber\"\u003eTable 2\u003c/div\u003e\u003cdiv class=\"CaptionContent\"\u003e\u003cp\u003ePatient demographics and case characteristics.\u003c/p\u003e\u003c/div\u003e\u003c/caption\u003e\u003ccolgroup cols=\"2\"\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e\u003cthead\u003e\u003ctr\u003e\u003cth align=\"left\" colspan=\"2\" nameend=\"c2\" namest=\"c1\"\u003e\u003cp\u003eSex\u003c/p\u003e\u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eFemale\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e22 (42.3%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eMale\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e30 (57.7%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colspan=\"2\" nameend=\"c2\" namest=\"c1\"\u003e\u003cp\u003e\u003cb\u003eEtiology\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eCongenital\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e12 (23.1%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eInfection\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e2 (3.8%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eSystematic disease\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e2 (3.8%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eTrauma\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e33 (63.5%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eTumor\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e3 (5.8%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colspan=\"2\" nameend=\"c2\" namest=\"c1\"\u003e\u003cp\u003e\u003cb\u003eType of operation\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eDelayed\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e13 (25.0%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003ePrimary\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e39 (75.0%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colspan=\"2\" nameend=\"c2\" namest=\"c1\"\u003e\u003cp\u003e\u003cb\u003eImplant material\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003ePEEK\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e9 (17.3%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eSilicone\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e14 (26.9%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003ePMMA\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e6 (11.5%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eTitanium\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e23 (44.23%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colspan=\"2\" nameend=\"c2\" namest=\"c1\"\u003e\u003cp\u003e\u003cb\u003eComplications\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eAsymmetry\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e1 (1.9%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eDiplopia\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e1 (1.9%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eExposure\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e2 (3.8%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eExtrusion\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e2 (3.8%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eHematoma\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e4 (7.7%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eInfection, rejection\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e2 (3.8%)\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eMean duration of operation in min\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e121.06\u0026thinsp;\u0026plusmn;\u0026thinsp;10.306\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\"\u003e\u003cp\u003eMean number of in-patient department bed days\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003e6.13\u0026thinsp;\u0026plusmn;\u0026thinsp;0.231\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/colgroup\u003e\u003c/table\u003e\u003c/div\u003e\u003c/p\u003e\u003c/div\u003e\u003cdiv id=\"Sec22\" class=\"Section3\"\u003e\u003ch2\u003e3.2.2 Complications\u003c/h2\u003e\u003cp\u003eIn a retrospective analysis of 52 craniomaxillofacial reconstruction cases, complications varied across the implant materials used. PEEK implants demonstrated a low complication rate, with hematoma occurring in 2 cases (22.2%) and no reports of extrusion, infection, or rejection. PMMA implants showed one case of extrusion (16.7%) but no other complications. Silicone implants exhibited a broader range of complications, including asymmetry (7.1%), extrusion (7.1%), and hematoma (7.1%), accounting for a total complication rate of 21.4%. Titanium implants had the highest complication rate, with cases of asymmetry and diplopia (4.5%), exposure (9.1%), hematoma (4.5%), and infection with rejection (9.1%), resulting in a total complication rate of 22.7% (Table\u0026nbsp;\u003cspan refid=\"Tab3\" class=\"InternalRef\"\u003e3\u003c/span\u003e).\u003c/p\u003e\u003cp\u003e\u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab3\" border=\"1\"\u003e\u003ccaption language=\"En\"\u003e\u003cdiv class=\"CaptionNumber\"\u003eTable 3\u003c/div\u003e\u003cdiv class=\"CaptionContent\"\u003e\u003cp\u003eComplications across the implant materials used during craniomaxillofacial surgeries.\u003c/p\u003e\u003c/div\u003e\u003c/caption\u003e\u003ccolgroup cols=\"4\"\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e\u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e\u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e\u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e\u003cthead\u003e\u003ctr\u003e\u003cth align=\"left\" colname=\"c1\"\u003e\u003cp\u003eMaterial of implants\u003c/p\u003e\u003c/th\u003e\u003cth align=\"left\" colname=\"c2\"\u003e\u003cp\u003eComplication\u003c/p\u003e\u003c/th\u003e\u003cth align=\"left\" colname=\"c3\"\u003e\u003cp\u003eValid\u003c/p\u003e\u003cp\u003epercent\u003c/p\u003e\u003c/th\u003e\u003cth align=\"left\" colname=\"c4\"\u003e\u003cp\u003eCumulative percent\u003c/p\u003e\u003c/th\u003e\u003c/tr\u003e\u003c/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\" morerows=\"1\" rowspan=\"2\"\u003e\u003cp\u003ePEEK\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003ehematoma\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e2\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e22.2\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eno\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e7\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e77.8\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\" morerows=\"1\" rowspan=\"2\"\u003e\u003cp\u003ePMMA\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eextrusion\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e1\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e16.7\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eno\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e5\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e83.3\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\" morerows=\"3\" rowspan=\"4\"\u003e\u003cp\u003eSilicone\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003easymmetry\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e1\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e7.1\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eextrusion\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e1\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e7.1\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003ehematoma\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e1\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e7.1\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eno\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e11\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e78.6\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c1\" morerows=\"4\" rowspan=\"5\"\u003e\u003cp\u003eTitanium\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003easymmetry, diplopia\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e1\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e4.5\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eexposure\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e2\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e9.1\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003ehematoma\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e1\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e4.5\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003einfection, rejection\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e2\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e9.1\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd align=\"left\" colname=\"c2\"\u003e\u003cp\u003eno\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e\u003cp\u003e17\u003c/p\u003e\u003c/td\u003e\u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e\u003cp\u003e77.3\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/colgroup\u003e\u003c/table\u003e\u003c/div\u003e\u003c/p\u003e\u003cp\u003eThe initial post-hoc power analysis, based on an assumed effect size of f\u0026thinsp;=\u0026thinsp;0.35, indicated that the available sample size (n\u0026thinsp;=\u0026thinsp;52) was sufficient to detect medium-to-large differences in complication rates among the implant groups at 80% power and α\u0026thinsp;=\u0026thinsp;0.05. However, the actual observed complication rates were similar across materials \u0026ndash; 22.2% for PEEK, 22.7% for titanium, and comparable frequencies for PMMA and silicone \u0026ndash; indicating that the true effect size may be smaller than anticipated.\u003c/p\u003e\u003cp\u003eGiven these findings, additional power calculations were conducted using more conservative effect sizes. When assuming f\u0026thinsp;=\u0026thinsp;0.25 or lower, the current sample size was found to be underpowered to detect small-to-moderate differences. This limitation suggests a reduced likelihood of identifying statistically relevant variations exist, particularly given the uneven distribution of cases across the four material groups.\u003c/p\u003e\u003cp\u003eTherefore, non-significant results in the comparison of complication rates should be interpreted with caution. The possibility of a type II error due to insufficient power especially in detecting subtle differences cannot be excluded. These constraints highlight the need for larger, more evenly distributed samples in future research to confirm or refute observed trends.\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv id=\"Sec23\" class=\"Section2\"\u003e\u003ch2\u003e3.3 Aesthetical outcomes\u003c/h2\u003e\u003cp\u003ePatient satisfaction with craniofacial reconstruction was assessed through an online survey covering five key aspects: aesthetic outcomes, symmetry, surgical site appearance, implant integration, and overall recommendation. The responses revealed significant differences between the four materials studied - PEEK, PMMA, silicone, and titanium which are shown in Appendix C.\u003c/p\u003e\u003cp\u003eFor aesthetic outcomes, PEEK implants achieved the highest ratings, with 66.7% of patients marking their satisfaction as \u0026ldquo;Highly satisfied\u0026rdquo; and 33.3% as \u0026ldquo;Harmonic\u0026rdquo;, indicating a consistently positive response. PMMA had mixed results, with 16.7% of patients \u0026ldquo;Highly satisfied\u0026rdquo;, 16.7% \u0026ldquo;Harmonic\u0026rdquo;, and 50% \u0026ldquo;As requested\u0026rdquo;. Silicone showed more variable results, with 42.9% rating as \u0026ldquo;Satisfied\u0026rdquo; or \u0026ldquo;As requested\u0026rdquo;, but only 7.1% achieving \u0026ldquo;Harmonic\u0026rdquo;. Titanium exhibited a wider range, with 43.5% marking \u0026ldquo;Harmonic\u0026rdquo; and 17.4% \u0026ldquo;Highly satisfied\u0026rdquo;, but also 17.4% rating as \u0026ldquo;Unsatisfied\u0026rdquo;, reflecting some dissatisfaction with its aesthetic outcomes.\u003c/p\u003e\u003cp\u003eFor symmetry, PEEK implants again led with 55.6% of patients rating \u0026ldquo;Highly satisfied\u0026rdquo;, 33.3% \u0026ldquo;Harmonic\u0026rdquo;, and 11.1% \u0026ldquo;Perfect\u0026rdquo;, showcasing excellent outcomes in this category. PMMA implants showed 66.7% \u0026ldquo;Harmonic\u0026rdquo;, 16.7% \u0026ldquo;Highly satisfied\u0026rdquo;, and 16.7% \u0026ldquo;Agreed\u0026rdquo;, indicating moderate success. Silicone results were split, with 42.9% rating as \u0026ldquo;Satisfied\u0026rdquo;, 28.6% \u0026ldquo;Harmonic\u0026rdquo;, and 14.3% \u0026ldquo;As requested\u0026rdquo;. Titanium showed strong results, with 39.1% \u0026ldquo;Highly satisfied\u0026rdquo;, 30.4% \u0026ldquo;Harmonic\u0026rdquo;, but also 8.7% \u0026ldquo;Unsatisfied\u0026rdquo;, reflecting variability in outcomes.\u003c/p\u003e\u003cp\u003eRegarding surgical site appearance, including scar visibility and contour, PEEK performed well, with 55.6% \u0026ldquo;Highly satisfied\u0026rdquo;, 33.3% \u0026ldquo;Harmonic\u0026rdquo;, and 11.1% \u0026ldquo;Perfect\u0026rdquo;. PMMA implants were also favourable, with 66.7% \u0026ldquo;Harmonic\u0026rdquo;, 16.7% \u0026ldquo;Highly satisfied\u0026rdquo;, and 16.7% \u0026ldquo;Satisfied\u0026rdquo;. Silicone was moderately rated, with 28.6% each for \u0026ldquo;Harmonic\u0026rdquo; and \u0026ldquo;As requested\u0026rdquo;, and 21.4% \u0026ldquo;Highly satisfied\u0026rdquo; or \u0026ldquo;Satisfied\u0026rdquo;. Titanium implants had 34.8% \u0026ldquo;Highly satisfied\u0026rdquo;, 21.7% \u0026ldquo;Harmonic\u0026rdquo;, 13% \u0026ldquo;Perfect\u0026rdquo;, but 4.3% \u0026ldquo;Unsatisfied\u0026rdquo;.\u003c/p\u003e\u003cp\u003eFor implant integration with natural facial structure, PEEK achieved exceptional results, with 77.8% \u0026ldquo;Highly satisfied\u0026rdquo; and 22.2% \u0026ldquo;Perfect\u0026rdquo;, indicating complete patient approval. PMMA showed 66.7% \u0026ldquo;Harmonic\u0026rdquo;, 16.7% \u0026ldquo;Highly satisfied\u0026rdquo;, and 16.7% \u0026ldquo;Agreed\u0026rdquo;. Silicone had mixed feedback, with 42.9% rating as \u0026ldquo;Satisfied\u0026rdquo; and \u0026ldquo;As requested\u0026rdquo;, and 14.3% as \u0026ldquo;Harmonic\u0026rdquo;. Titanium was more varied, with 39.1% \u0026ldquo;Highly satisfied\u0026rdquo;, 21.7% \u0026ldquo;Harmonic\u0026rdquo;, and 8.7% \u0026ldquo;Unsatisfied\u0026rdquo;. Average ANA scores of patient satisfaction with craniofacial reconstruction presented in Fig.\u0026nbsp;\u003cspan refid=\"Fig8\" class=\"InternalRef\"\u003e4\u003c/span\u003e.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eFinally, for recommendations, 100% of PEEK patients would recommend the material, compared to 83.3% for PMMA, 71.4% for silicone, and 73.9% for titanium.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eIn summary, PEEK consistently outperformed the other materials across all categories, achieving the highest satisfaction ratings for aesthetics, symmetry, site appearance, and implant integration, coupled with universal patient recommendations. PEEK implants resulted in a mean ANA score of 8.86 (SD\u0026thinsp;=\u0026thinsp;0.35; 8.25\u0026ndash;9.25). Furthermore, the Kruskal-Wallis test revealed a statistically significant difference (H\u0026thinsp;=\u0026thinsp;16.7605, df\u0026thinsp;=\u0026thinsp;3, p\u0026thinsp;=\u0026thinsp;0.000792).\u003c/p\u003e\u003c/div\u003e"},{"header":"4. Discussion","content":"\u003cp\u003eThe presented study examined several commonly used implant materials - PEEK, titanium, PMMA, and silicone in craniomaxillofacial reconstruction. This discussion synthesizes the findings with complications reported in other studies, providing a comparative perspective.\u003c/p\u003e\u003cp\u003eThe gathered data demonstrated the advantages of PEEK implants, including superior mechanical properties, aesthetic outcomes, and patient satisfaction. In our cohort of 52 cases, PEEK showed minimal complications, with only two hematoma cases. Patient satisfaction was high, with 77.8% rating implant integration as \u0026ldquo;highly satisfied\u0026rdquo; and 100% recommending it. Comparatively, Ha et al. (\u003cspan citationid=\"CR81\" class=\"CitationRef\"\u003e81\u003c/span\u003e) reported complications in 17.2% of their 29 cases with PEEK and titanium implants alloy, including screw loosening, dissatisfaction, and postoperative infections. Nguyen et al. (2018) documented a 4.4% infection rate in PEEK reconstructions among 136 cases. Li et al. (\u003cspan citationid=\"CR81\" class=\"CitationRef\"\u003e81\u003c/span\u003e) documented implant exposure in one patient (16.7%) among six patients after 10 months, while Ahmad et al. (\u003cspan citationid=\"CR81\" class=\"CitationRef\"\u003e81\u003c/span\u003e) observed implant removal due to recurrent infection in one case (10%) out of 10 patients. Anabtawi et al. (2021) identified complications in three cases (30%) among 10 patients, including recurrent oedema, bilateral mental nerve paraesthesia, and recurrent sinusitis. Alonso-Rodriguez et al. (2015) reported infections in two cases (14.3%) among 14 patients, with one requiring implant removal. Similarly, Kim et al. (2009) noted dehiscence in one patient (25%) among four with complex defects, and O\u0026rsquo;Reilly et al. (2015) described complications among 19 patients, including two cases of MRSA wound infections, one case of traumatic exposure, one poor cosmetic outcome, and one case of epidural fluid collection. Despite these reported complications, the rates remain relatively low and are often case-specific. These findings reinforce PEEK\u0026rsquo;s reputation as a reliable material with consistent clinical and aesthetic outcomes. However, the bio-inert nature of PEEK and occasional postoperative challenges (e.g., infection or exposure) highlight the need for further innovations in surface modifications to enhance osteoconductivity and reduce infection risks.\u003c/p\u003e\u003cp\u003eTitanium implants had a complication rate of 22.7%, including infection, hematoma, and implant exposure. Patient satisfaction was varied, with 39.1% highly satisfied but 8.7% unsatisfied. D\u0026uuml;zg\u0026uuml;n et al. (2020) observed similar trends in their 62 orbital reconstruction cases, reporting complications such as infection (1.6%), permanent diplopia (1.6%), and enophthalmos (1.6%). Chen et al. (2015) highlighted delayed healing in 28.6% of cases, particularly in diabetic patients. Nguyen et al. (2018) reported one infection and one case of dehiscence in titanium implants. These data underscore titanium\u0026rsquo;s utility in load bearing but its limitations in aesthetics outcomes.\u003c/p\u003e\u003cp\u003eOn the other hand, PMMA implants achieved a moderate satisfaction rate (66.7% rated symmetry as \u0026ldquo;harmonic\u0026rdquo;) but faced complications in 16.7% of cases, including implant extrusion. These align with Sch\u0026ouml;n et al. (2021), who reported a 43.8% complication rate in 16 skull defect cases, including extra-axial hematomas (37.5%). Ming-Chi Hsieh et al. (2020) documented a 13.3% complication rate in occipital augmentation with PMMA implants, and Desai et al. (2019) noted a 13.3% infection rate in 30 cranioplasty cases. Our results align with these studies, highlighting its limitations in load-bearing regions and susceptibility to infection and extrusion.\u003c/p\u003e\u003cp\u003eFinally, silicone had a complication rate of 21.4%, including asymmetry, extrusion, and patient dissatisfaction (rated appearance as \u0026ldquo;harmonic\u0026rdquo;). Al-Jandan et al. (2018) reported a 4.3% infection rate and a 13.8% displacement rate in 58 mandibular augmentation cases. Similarly, Kook et al. (2023) and Pelle-Ceravolo et al. (\u003cspan citationid=\"CR81\" class=\"CitationRef\"\u003e81\u003c/span\u003e) identified frequent complications, including infections, resorption, and implant displacement. These findings mirror the results from this study, confirming the high rates of revision and mixed aesthetic outcomes associated with silicone.\u003c/p\u003e\u003cp\u003ePEEK demonstrates promising outcomes as an implant material, particularly in aesthetics and patient satisfaction. However, further comparative studies with longer follow-up are warranted to confirm its superiority over other materials. Despite promising findings, the claim of PEEK\u0026rsquo;s superiority must be interpreted with caution due to higher cost, limited global availability, and lack of long-term multicentric studies.\u003c/p\u003e\u003cp\u003eComplications associated with PEEK implants appear to vary depending on the anatomical site of reconstruction. In current study, the two cases of hematoma associated with PEEK occurred in the frontal and parietal regions, where extensive subgaleal dissection and vascular plexus manipulation increase bleeding risk postoperatively. No complications were recorded in PEEK reconstruction involving the mandibular contour, zygoma, or infraorbital regions, which may reflect lower vascular density and more rigid tissue compartments. This suggests that complication profiles of PEEK implants are highly site-specific, emphasising the need for tailored surgical planning based on regional anatomy, soft tissue envelope, and vascularity. Optimising implant design to anatomical contours and ensuring adequate soft tissue coverage are critical to minimising complications in high-risks zones.\u003c/p\u003e\u003cp\u003eIn conclusion, while each material has specific advantages and limitations, PEEK offers the most balanced combination of mechanical properties, aesthetic outcomes, and patient satisfaction, with a lower risk of complications. Titanium remains effective for load-bearing applications but may require adjunctive measures to address aesthetic concerns. PMMA and silicone are best suited for selective cases but require caution due to their associated risks. These findings highlight the importance of personalised material selection in optimising reconstructive outcomes.\u003c/p\u003e"},{"header":"Conclusion","content":"\u003cp\u003eThis study highlights the importance of material selection in craniomaxillofacial reconstruction to achieve optimal functional and aesthetic outcomes. PEEK emerged as the most promising material due to its superior patient satisfaction, low complication rates, and balanced mechanical and aesthetic properties. However, based on the findings and literature review, implant material selection in craniomaxillofacial reconstruction should be guided by anatomical location, functional load requirements, soft tissue coverage, patient comorbidities, and aesthetic expectations. PEEK implants are most suitable for moderate-load, aesthetically sensitive regions such as the zygoma, infraorbital rim, frontal bone, and mandibular angle, where its radiolucency and contouring precision are advatageous. Titanium remains effective for high-load-bearing areas, such as mandibular body and condyle, due to its strength and osseintegration capacity. Its use in aesthetic zones may be limited when soft tissue is thin, due to increased risk of exposure and palpability. PMMA is well-suited for cranial vault and frontal bone reconstruction, especially when economic constraints or availability limit other options. However, due to its exothermic curing and infection risk, it should be avoided in load-bearing areas or where soft tissue is limited. Silicone implants are appropriate for selective aesthetic augmentations, such as the chin and nasal dorsum, particularly when cost-effective options are needed, and soft tissue coverage is sufficient. Its use should be limited in areas with dynamic soft tissue movement or bone resorption risk. Incorporating these practical considerations into preoperative planning may optimise outcomes, minimise complications, and support patient-centered care.\u003c/p\u003e"},{"header":"Abbreviations","content":"\u003cdiv class=\"DefinitionList\"\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003ePEEK\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003epolyetheretherketone\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003ePMMA\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003epolymethylmethacrylate\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eHA\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003ehydroxyapatite\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003ePICO\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003eThe Population, Intervention, Comparison, Outcome\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003ePRISMA\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003ePreferred Items for Systematic Reviews and Meta-Analyses\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eCAD/CAM\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003eComputer-aided design and manufacturing\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003e3D\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003ethree-dimensional\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eCT\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003ecomputed tomography\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eJBI\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003eJoanna Briggs Institute\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eROBINS-I\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003eRisk of Bias in Non-Randomised Studies of Interventions\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eUK\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003ethe United Kingdom\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eNSAID\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003enonsteroidal anti-inflammatory drug\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eMRSA\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003eMethicillin-resistant Staphylococcus aureus\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003cdiv class=\"DefinitionListEntry\"\u003e\u003cdiv class=\"Term\"\u003eANA\u003c/div\u003e\u003cdiv class=\"Description\"\u003e\u003cp\u003eAesthetic Numeric Analogue\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/div\u003e"},{"header":"Declarations","content":"\u003ch2\u003eEthics statement and consent statement\u003c/h2\u003e\n\u003cp\u003eThe study protocol was approved by the Research Ethics Committee of the King\u0026rsquo;s College London (Ref. number LRS/DP-24/25-4531 from October 3, 2024). All procedures were conducted in accordance with the Declaration of Helsinki. Informed consent was obtained from all participants. All participants provided consent for the publication of anonymized data.\u003c/p\u003e\u003ch2\u003eFunding statement\u003c/h2\u003e\u003cp\u003eNo funding was obtained.\u003c/p\u003e\u003ch2\u003eAuthor Contribution\u003c/h2\u003e\u003cp\u003eManuscript Title: Polyetheretherketone for craniomaxillofacial defects: cases report, evaluation of patients\u0026rsquo; satisfaction and a systematic literature reviewList of all Authors: Yuliya Menchisheva, Alvaro Varela Morillas, Nunzianda FrascioneCorresponding Author: Yuliya MenchishevaThis statement is to certify that all authors have seen and approved the manuscript being submitted, have contributed significantly to the work, attest to the validity and legitimacy of the data and its interpretation, and agree to its submission to the Maxillofacial Plastic and Reconstructive Surgery.Authors' contributionsY Menchisheva: Project development, Investigation, Methodology, Data collection, Data analysis, Manuscript writing and editing.AV Morillas: Project development, Visualization, Manuscript writing and editing.N Frascione: Supervision, Project development, Manuscript writing and editing.We the undersigned declare that this manuscript is original, has not been published before and is not currently being considered for publication elsewhere. We confirm that the manuscript has been read and approved by all named authors and that there are no other persons who satisfied the criteria for authorship but are not listed. We further confirm that the order of authors listed in the manuscript has been approved by all of us. We understand that the Corresponding Author is the sole contact for the Editorial process. She is responsible for communicating with the other authors about progress, submissions of revisions and final approval of proofs Signed by all authors as follows: Yuliya MenchishevaAlvaro Varela MorillasNunzianda Frascione\u003c/p\u003e\u003ch2\u003eData Availability\u003c/h2\u003e\u003cp\u003eThe datasets generated and analysed during the current study are availbale from the corresponding author upon reasonable request. Data sharing is subject to institutional and ethical regulations to protect participant confidentiality.\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\u003cli\u003e\u003cspan\u003eGerbino G, Zavattero E, Zenga F, Bianchi FA, Garzino-Demo P, Berrone S (2015) Primary and secondary reconstruction of complex craniofacial defects using polyetheretherketone custom-made implants. J Craniomaxillofac Surg 43(8):1356\u0026ndash;1363\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAlasseri N, Alasraj A (2020) Patient-specific implants for maxillofacial defects: challenges and solutions. Maxillofac Plast Reconstr Surg 42(1):15\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eKumar BP, Venkatesh V, Kumar KA, Yadav BY, Mohan SR (2016) Mandibular Reconstruction: Overview. J Maxillofac Oral Surg 15(4):425\u0026ndash;441\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePanayotov IV, Orti V, Cuisinier F, Yachouh J (2016) Polyetheretherketone (PEEK) for medical applications. J Mater Sci Mater Med 27(7):118\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eJessop ZM, Hague A, Dobbs TD, Stewart KJ, Whitaker IS (2021) Facial Cartilaginous Reconstruction-A Historical Perspective, State-of-the-Art, and Future Directions. Front Surg 8:680186\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eMoharil S, Reche A, Durge K (2023) Polyetheretherketone (PEEK) as a Biomaterial: An Overview. Cureus 15(8):e44307\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eLi Y, Li Z, Tian L, Li D, Lu B, Shi C et al (2022) Clinical application of 3D-printed PEEK implants for repairing mandibular defects. J Craniomaxillofac Surg 50(8):621\u0026ndash;626\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eNocini R, D'Agostino A, Trevisiol L, Favero V (2022) Mandibular recontouring with polyetheretherketone (PEEK) patient-specific implants. BMJ Case Rep. ;15(4)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAhmad AF, Yaakob H, Khalil A, Georges P (2022) Evaluating patients' satisfaction level after using 3D printed PEEK facial implants in repairing maxillofacial deformities. Ann Med Surg (Lond) 79:104095\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAlonso-Rodriguez E, Cebri\u0026aacute;n JL, Nieto MJ, Del Castillo JL, Hern\u0026aacute;ndez-Godoy J, Burgue\u0026ntilde;o M (2015) Polyetheretherketone custom-made implants for craniofacial defects: Report of 14 cases and review of the literature. J Cranio-Maxillofacial Surg 43(7):1232\u0026ndash;1238\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eYan K, Wu Y, Xie Z, Yan S, Qiao C, Qu Y et al (2024) Endoscopic-Assisted Forehead Augmentation with Polyetheretherketone (PEEK) Patient-Specific Implant (PSI) for Aesthetic Considerations. Aesthetic Plast Surg 48(10):1889\u0026ndash;1898\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eNarciso R, Basile E, Bottini DJ, Cervelli V (2021) PEEK Implants: An Innovative Solution for Facial Aesthetic Surgery. Case Rep Surg 2021:5518433\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eKauke-Navarro M, Knoedler L, Knoedler S, Deniz C, Stucki L, Safi AF (2024) Balancing beauty and science: a review of facial implant materials in craniofacial surgery. Front Surg 11:1348140\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAnabtawi M, Thomas M, Lee NJ (2021) The Use of Interlocking Polyetheretherketone (PEEK) Patient-Specific Facial Implants in the Treatment of Facial Deformities. A Retrospective Review of Ten Patients. J Oral Maxillofac Surg 79(5):1145. \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e.e1-.e9\u003c/span\u003e\u003cspan address=\"http://.e1-.e9\" targettype=\"URL\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eKim MM, Boahene KD, Byrne PJ (2009) Use of customized polyetheretherketone (PEEK) implants in the reconstruction of complex maxillofacial defects. Arch Facial Plast Surg 11(1):53\u0026ndash;57\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAtef M, Mounir M, Shawky M, Mounir S, Gibaly A (2022) Polyetheretherketone patient-specific implants (PPSI) for the reconstruction of two different mandibular contour deformities. Oral Maxillofac Surg 26(2):299\u0026ndash;309\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eHabib LA, Yoon MK (2021) Patient specific implants in orbital reconstruction: A pilot study. Am J Ophthalmol Case Rep 24:101222\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eJalbert F, Boetto S, Nadon F, Lauwers F, Schmidt E, Lopez R (2014) One-step primary reconstruction for complex craniofacial resection with PEEK custom-made implants. J Craniomaxillofac Surg 42(2):141\u0026ndash;148\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePage MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD et al (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372:n71\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eHaddaway NR, Page MJ, Pritchard CC, McGuinness LA (2022) PRISMA2020: An R package and Shiny app for producing PRISMA 2020-compliant flow diagrams, with interactivity for optimised digital transparency and Open Synthesis. Campbell Syst Rev 18(2):e1230\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ede Vet HCW, Dikmans RE, Eekhout I (2017) Specific agreement on dichotomous outcomes can be calculated for more than two raters. J Clin Epidemiol 83:85\u0026ndash;89\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eSarfraz S, M\u0026auml;ntynen PH, Laurila M, Rossi S, Leikola J, Kaakinen M et al (2022) Comparison of Titanium and PEEK Medical Plastic Implant Materials for Their Bacterial Biofilm Formation Properties. Polym (Basel). ;14(18)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eMeyer H, Khalid SI, Dorafshar AH, Byrne RW (2021) The Materials Utilized in Cranial Reconstruction: Past, Current, and Future. Plast Surg (Oakv) 29(3):184\u0026ndash;196\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePan Z, Patil PM (2014) Titanium osteosynthesis hardware in maxillofacial trauma surgery: to remove or remain? A retrospective study. Eur J Trauma Emerg Surg 40(5):587\u0026ndash;591\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eQuatela VC, Chow J (2008) Synthetic facial implants. Facial Plast Surg Clin North Am 16(1):1\u0026ndash;10\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eFaot F, Nascimento GG, Bielemann AM, Camp\u0026atilde;o TD, Leite FR, Quirynen M (2015) Can peri-implant crevicular fluid assist in the diagnosis of peri-implantitis? A systematic review and meta-analysis. J Periodontol 86(5):631\u0026ndash;645\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePietzka S, Wenzel M, Winter K, Wilde F, Schramm A, Ebeling M et al (2023) Comparison of Anatomical Preformed Titanium Implants and Patient-Specific CAD/CAM Implants in the Primary Reconstruction of Isolated Orbital Fractures-A Retrospective Study. J Pers Med. ;13(5)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eRotaru H, Schumacher R, Kim S-G, Dinu C (2015) Selective laser melted titanium implants: a new technique for the reconstruction of extensive zygomatic complex defects. Maxillofacial Plast Reconstr Surg 37(1):1\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eLi J, Li P, Lu H, Shen L, Tian W, Long J et al (2013) Digital design and individually fabricated titanium implants for the reconstruction of traumatic zygomatico-orbital defects. J Craniofac Surg 24(2):363\u0026ndash;368\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eChattopadhyay C (2019) Reconstruction of Acquired Frontal Bone Defects Using Titanium Mesh Implants: A Retrospective Study. J Maxillofac Oral Surg 18(1):34\u0026ndash;39\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003e\u0026agrave;Wengen DF (2022) Titanium Implants in the Nose: State of the Art. Facial Plast Surg 38(5):461\u0026ndash;467\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAl-Sukhun J (2023) A Novel Method to Reconstruct the Upper and Lower Jaws Using 3D-Custom-Made Titanium Implants. J Craniofac Surg 34(3):e244\u0026ndash;e6\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eLim H-K, Choi Y-J, Choi W-C, Song I-S, Lee U-L (2022) Reconstruction of maxillofacial bone defects using patient-specific long-lasting titanium implants. Sci Rep 12(1):7538\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eMounir M, Abou-ElFetouh A, ElBeialy W, Mounir R (2020) Patient-specific alloplastic endoprosthesis for reconstruction of the mandible following segmental resection: A case series. J Craniomaxillofac Surg 48(8):719\u0026ndash;723\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eWoo JM, Baek SH, Kim JC, Choi JY (2018) Contour Restoration of Over-Resected Mandibular Angle and Lower Border by Reduction Mandibuloplasty Using Three-Dimensional Planning and Computer-Aided Design and Manufacturing Custom-Made Titanium Implants. J Craniofac Surg 29(4):e340\u0026ndash;e3\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eBasketter DA, Whittle E, Monk B (2000) Possible allergy to complex titanium salt. Contact Dermat 42(5):310\u0026ndash;311\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePigatto PD, Guastella C, Guzzi G (2017) Titanium Exposure Outcome in Facial Plastic and Reconstructive Surgery. Plast Reconstr Surg. ;139(1)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePoli PP, de Miranda FV, Polo TOB, Santiago J\u0026uacute;nior JF, Lima Neto TJ, Rios BR et al (2021) Titanium Allergy Caused by Dental Implants: A Systematic Literature Review and Case Report. Mater (Basel). ;14(18)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eGafar Ahmed M, AlHammad ZA, Al-Jandan B, Almohammadi T, Khursheed Alam M, Bagde H (2023) Silicone Facial Implants, to Fixate or Not to Fixate: A Narrative Review. Cureus 15(2):e34524\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eRojas YA, Sinnott C, Colasante C, Samas J, Reish RG (2018) Facial Implants: Controversies and Criticism. A Comprehensive Review of the Current Literature. Plast Reconstr Surg 142(4):991\u0026ndash;999\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAl-Jandan B, Marei HF (2018) Mandibular angle augmentation using solid silicone implants. Dent Med Probl 55(4):367\u0026ndash;370\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eRubin JP, Yaremchuk MJ (1997) Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature. Plast Reconstr Surg 100(5):1336\u0026ndash;1353\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eKook WS, Ryu DH, Baek W, Kook HM, Jang YY, Lew DH (2023) Prevention and Resolution of Silicone Implant-Related Problems in Secondary Rhinoplasty Using a Cross-Linked Human Acellular Dermal Matrix. Plast Reconstr Surg 152(1):45\u0026ndash;54\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eSlupchynskyj O, Rahimi M (2014) Revision rhinoplasty in ethnic patients: pollybeak deformity and persistent bulbous tip. Facial Plast Surg 30(4):477\u0026ndash;484\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePelle-Ceravolo M, Angelini M (2022) Zygomatic Implants through a Face-Lift Approach: Analysis of 30 Years' Experience. Plast Reconstr Surg 150(5):995\u0026ndash;1005\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eGosau M, Schiel S, Draenert GF, Ihrler S, Mast G, Ehrenfeld M (2006) [Craniofacial augmentation with porous polyethylene implants (Medpor: first clinical results]. Mund Kiefer Gesichtschir 10(3):178\u0026ndash;184\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eNiechajev I (2012) Facial reconstruction using porous high-density polyethylene (medpor): long-term results. Aesthetic Plast Surg 36(4):917\u0026ndash;927\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eGriffin M, Kalaskar D, Butler P (2019) Argon plasma modified nanocomposite polyurethane scaffolds provide an alternative strategy for cartilage tissue engineering. J Nanobiotechnol 17(1):51\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eKu PKM, Vlantis AC, Tong MC, Chan TTT, Yeung ZWC, Cho RHW et al (2024) A Hybrid Auricular Framework of Autologous Rib Cartilage and a Porous Polyethylene Implant for Reconstruction of Congenital Microtia: A Modification of Nagata's Technique. Facial Plast Surg Aesthet Med 26(1):15\u0026ndash;22\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eScopelliti D, Amodeo G (2016) Nasal Dorsum Reconstruction With Alloplastic Material. J Craniofac Surg 27(7):e676\u0026ndash;e8\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003ePark JH, Kim JW, Kim SJ (2016) Midfacial Soft-Tissue Changes after Paranasal Augmentation with Porous Polyethylene. Facial Plast Surg 32(2):232\u0026ndash;237\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eGroth MJ, Bhatnagar A, Clearihue WJ, Goldberg RA, Douglas RS (2006) Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects. Arch Facial Plast Surg 8(6):381\u0026ndash;389\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eGhosh S, Pramanick D, Ray A, Burman R, Saha A (2017) Fronto-orbital reconstruction using polymethyl methacrylate implant. Natl J Maxillofac Surg 8(2):153\u0026ndash;156\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eMartinez-Seijas P, D\u0026iacute;az-Galvis LA, Hernando J, Leizaola-Cardesa IO, Aguilar-Salvatierra A, G\u0026oacute;mez-Moreno G (2018) Polymethyl Methacrylate Custom-Made Prosthesis: A Novel Three-Dimension Printing-Aided Fabrication Technique for Cranial and/or Orbital Reconstruction. J Craniofac Surg 29(5):e438\u0026ndash;e40\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eSch\u0026ouml;n SN, Skalicky N, Sharma N, Zumofen DW, Thieringer FM (2021) 3D-Printer-Assisted Patient-Specific Polymethyl Methacrylate Cranioplasty: A Case Series of 16 Consecutive Patients. World Neurosurg 148:e356\u0026ndash;e62\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eBruens ML, Pieterman H, de Wijn JR, Vaandrager JM (2003) Porous polymethylmethacrylate as bone substitute in the craniofacial area. J Craniofac Surg 14(1):63\u0026ndash;68\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eJain R, Mahendru S, Aggarwal A, Brajesh V, Aulakh HS, Singh S et al (2021) Feasibility of Customised Polymethyl Methacrylate Implants Fabricated Using 3D Printed Flexible Moulds for Correction of Facial Skeletal Deformities. J Craniofac Surg 32(6):1981\u0026ndash;1985\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eFernandes da Silva AL, Borba AM, Sim\u0026atilde;o NR, Pedro FL, Borges AH, Miloro M (2014) Customized polymethyl methacrylate implants for the reconstruction of craniofacial osseous defects. Case Rep Surg 2014:358569\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eAldabib J (2020) Reinforcement of poly (methyl methacrylate) denture base material. Dent Med Journal-Review 2(2):46\u0026ndash;53\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eThayaparan GK, Lewis PM, Thompson RG, D'Urso PS (2021) Patient-specific implants for craniomaxillofacial surgery: A manufacturer's experience. Ann Med Surg (Lond) 66:102420\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eHsieh TY, Dhir K, Binder WJ, Hilger PA (2021) Alloplastic Facial Implants. Facial Plast Surg 37(6):741\u0026ndash;750\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eOliver JD, Eells AC, Saba ES, Boczar D, Restrepo DJ, Huayllani MT et al (2019) Alloplastic Facial Implants: A Systematic Review and Meta-Analysis on Outcomes and Uses in Aesthetic and Reconstructive Plastic Surgery. Aesthetic Plast Surg 43(3):625\u0026ndash;636\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eLe\u0026atilde;o RS, Maior JRS, Lemos CAA, Vasconcelos B, Montes M, Pellizzer EP et al (2018) Complications with PMMA compared with other materials used in cranioplasty: a systematic review and meta-analysis. Braz Oral Res 32:e31\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eKattimani VS, Chakravarthi PS, Prasad LK (2016) Biograft Block Hydroxyapatite: A Ray of Hope in the Reconstruction of Maxillofacial Defects. J Craniofac Surg 27(1):247\u0026ndash;252\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eSystermans S, Cobraiville E, Camby S, Meyer C, Louvrier A, Lie SA et al (2024) An innovative 3D hydroxyapatite patient-specific implant for maxillofacial bone reconstruction: A case series of 13 patients. J Craniomaxillofac Surg 52(4):420\u0026ndash;431\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eBrie J, Chartier T, Chaput C, Delage C, Pradeau B, Caire F et al (2013) A new custom made bioceramic implant for the repair of large and complex craniofacial bone defects. J Craniomaxillofac Surg 41(5):403\u0026ndash;407\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eStaffa G, Barbanera A, Faiola A, Fricia M, Limoni P, Mottaran R et al (2012) Custom made bioceramic implants in complex and large cranial reconstruction: a two-year follow-up. J Craniomaxillofac Surg 40(3):e65\u0026ndash;70\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eHuggins RJ, Mendelson BC (2016) Biologic Behavior of Hydroxyapatite Used in Facial Augmentation. Aesthetic Plast Surg 41(1):179\u0026ndash;184\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eSiddiqui HA, Pickering KL, Mucalo MR (2018) A Review on the Use of Hydroxyapatite-Carbonaceous Structure Composites in Bone Replacement Materials for Strengthening Purposes. Mater (Basel). ;11(10)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eZhang L, Shen S, Yu H, Shen SG, Wang X (2015) Computer-Aided Design and Computer-Aided Manufacturing Hydroxyapatite/Epoxide Acrylate Maleic Compound Construction for Craniomaxillofacial Bone Defects. J Craniofac Surg 26(5):1477\u0026ndash;1481\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eBawn C (1987) Encyclopedia of polymer science and engineering. Polymer 28(7):1234\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eNigam M, Kotha V, Weinzweig J, Baker SB (2022) 30 - Aesthetic cranioplasty. In: Baker SB, Patel PK, Weinzweig J (eds) Aesthetic Surgery of the Facial Skeleton. Elsevier, London, pp 299\u0026ndash;310\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eMa R, Tang T (2014) Current strategies to improve the bioactivity of PEEK. Int J Mol Sci 15(4):5426\u0026ndash;5445\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eLong J, Zhang J, Kang J, Fan Y, Zhang Z, Shi J et al (2023) Customed 3D-printed Polyetheretherketone (PEEK) Implant for Secondary Salvage Reconstruction of Mandibular Defects: Case Report and Literature Review. J Craniofac Surg 34(8):2460\u0026ndash;2463\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eNieminen T, Kallela I, Wuolijoki E, Kainulainen H, Hiidenheimo I, Rantala I (2008) Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow‐up. J Biomedical Mater Res Part A 84(2):377\u0026ndash;383\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eLommen J, Schorn L, Sproll C, Haussmann J, K\u0026uuml;bler NR, Budach W et al (2022) Reduction of CT Artifacts Using Polyetheretherketone (PEEK), Polyetherketoneketone (PEKK), Polyphenylsulfone (PPSU), and Polyethylene (PE) Reconstruction Plates in Oral Oncology. J Oral Maxillofac Surg 80(7):1272\u0026ndash;1283\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eShah AM, Jung H, Skirboll S (2014) Materials used in cranioplasty: a history and analysis. NeuroSurg Focus 36(4):E19\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eChen J, Xiao J, Han X, Sima X, Guo W (2023) An HA/PEEK scaffold with modified crystallinity via 3D-bioprinting for multiple applications in hard tissue engineering. Biomed Mater. ;18(6)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eYu D, Lei X, Zhu H (2022) Modification of polyetheretherketone (PEEK) physical features to improve osteointegration. J Zhejiang Univ Sci B 23(3):189\u0026ndash;203\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eDondani JR, Iyer J, Tran SD (2023) Surface Treatments of PEEK for Osseointegration to Bone. Biomolecules. ;13(3)\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan\u003eWHO Classification of Tumours Editorial Board. Head and neck tumours. Lyon (France): International Agency for Research on Cancer (2022) (WHO classification of tumours series te\u003c/span\u003e\u003c/li\u003e\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"
[email protected]","identity":"maxillofacial-plastic-and-reconstructive-surgery","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"mprs","sideBox":"Learn more about [Maxillofacial Plastic and Reconstructive Surgery](http://jkamprs.springeropen.com/)","snPcode":"40902","submissionUrl":"https://submission.springernature.com/new-submission/40902/3","title":"Maxillofacial Plastic and Reconstructive Surgery","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Springer Open","inReviewEnabled":true,"inReviewRevisionsEnabled":true},"keywords":"PEEK, Reconstruction, Surgical procedures, Postoperative complications, Patient outcome assessment, Implant materials","lastPublishedDoi":"10.21203/rs.3.rs-7289687/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-7289687/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003e\u003cstrong\u003eBackground\u003c/strong\u003e: Craniomaxillofacial reconstruction poses significant clinical challenges due to the complexity of the anatomy and the varied causes of defects. Selecting the optimal implant material remains a crucial factor in achieving successful functional and aesthetic outcomes.\u003c/p\u003e\n\u003cp\u003eThis study combined a systematic review and a retrospective case series conducted at the Hospital 5, Almaty, Kazakhstan. The sample consisted of 52 patients who underwent craniomaxillofacial reconstruction between 2021 and 2024, receiving either PEEK, titanium, PMMA, or silicone implants. Following the surgical procedures, patients were invited to participate in an online survey to evaluate their satisfaction with long-term outcomes.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eResults\u003c/strong\u003e: PEEK implants demonstrated the complication rate at 22.2%, attributable only to hematoma. Titanium implants exhibited the complication rate - 22.7%, with cases of asymmetry and diplopia (4.5%), exposure (9.1%), hematoma (4.5%), and infection with rejection (9.1%). Aesthetic outcome scores, measured by the ANA scale, varied across materials. PEEK implants achieved the highest mean ANA rating with 8.86 (SD=0.35; 8.25 – 9.25), showing a significant difference over PMMA, silicone and titanium\u003cstrong\u003e.\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eConclusions\u003c/strong\u003e: PEEK implants demonstrated promising clinical and aesthetic outcomes in craniomaxillofacial reconstruction. However, material selection should be personalised, considering defect location, soft tissue coverage to optimise results.\u003c/p\u003e","manuscriptTitle":"Polyetheretherketone for Craniomaxillofacial Defects: Cases Report, Evaluation of Patients’ Satisfaction and a Systematic Literature Review","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2025-08-17 14:05:44","doi":"10.21203/rs.3.rs-7289687/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"decision","content":"Revision requested","date":"2025-08-19T03:43:30+00:00","index":"","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2025-08-19T02:44:33+00:00","index":"hide","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2025-08-18T23:35:00+00:00","index":"hide","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2025-08-10T22:18:33+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"229006759860991461845807086851775487348","date":"2025-08-10T02:36:37+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"2467410865898792618859647277997360348","date":"2025-08-08T08:29:56+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"242556787801490691688468794117838544389","date":"2025-08-08T06:19:23+00:00","index":"hide","fulltext":""},{"type":"reviewersInvited","content":"","date":"2025-08-08T01:15:54+00:00","index":"","fulltext":""},{"type":"editorAssigned","content":"","date":"2025-08-07T09:40:41+00:00","index":"","fulltext":""},{"type":"checksComplete","content":"","date":"2025-08-07T09:38:59+00:00","index":"","fulltext":""},{"type":"submitted","content":"Maxillofacial Plastic and Reconstructive Surgery","date":"2025-08-04T09:47:56+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"
[email protected]","identity":"maxillofacial-plastic-and-reconstructive-surgery","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"mprs","sideBox":"Learn more about [Maxillofacial Plastic and Reconstructive Surgery](http://jkamprs.springeropen.com/)","snPcode":"40902","submissionUrl":"https://submission.springernature.com/new-submission/40902/3","title":"Maxillofacial Plastic and Reconstructive Surgery","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Springer Open","inReviewEnabled":true,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"9d709372-7756-4f93-9573-7127384119ad","owner":[],"postedDate":"August 17th, 2025","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[],"tags":[],"updatedAt":"2025-10-27T16:33:28+00:00","versionOfRecord":{"articleIdentity":"rs-7289687","link":"https://doi.org/10.1186/s40902-025-00482-9","journal":{"identity":"maxillofacial-plastic-and-reconstructive-surgery","isVorOnly":false,"title":"Maxillofacial Plastic and Reconstructive Surgery"},"publishedOn":"2025-10-24 16:16:31","publishedOnDateReadable":"October 24th, 2025"},"versionCreatedAt":"2025-08-17 14:05:44","video":"","vorDoi":"10.1186/s40902-025-00482-9","vorDoiUrl":"https://doi.org/10.1186/s40902-025-00482-9","workflowStages":[]},"version":"v1","identity":"rs-7289687","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-7289687","identity":"rs-7289687","version":["v1"]},"buildId":"XKTyCvWXoU3ODBz1xrDgd","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.