MPV vs. Optical Platelet Volume Measurement: Which Is a Better Indicator for Neonatal Sepsis?

preprint OA: closed
Full text JSON View at publisher
Full text 65,321 characters · extracted from preprint-html · click to expand
MPV vs. Optical Platelet Volume Measurement: Which Is a Better Indicator for Neonatal Sepsis? | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Article MPV vs. Optical Platelet Volume Measurement: Which Is a Better Indicator for Neonatal Sepsis? Hao Yang, Jiqian Bao, Siqi Guo, Jiajing He, Lei Ye, Yingjun Zhang, and 2 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-5332746/v1 This work is licensed under a CC BY 4.0 License Status: Posted Version 1 posted You are reading this latest preprint version Abstract Objective To evaluate the accuracy of mean platelet volume (MPV) testing in the neonatal population and assess the applicability of the optical platelet volume measurement method on Sysmex XN9000 in this demographic. Method From June 2023 to June 2024, we analyzed complete blood count (CBC) data from 1070 neonates with infections to assess MPV testing reliability using instrument alerts and histograms. Additionally, 284 neonates without infections or hematologic diseases were included to evaluate the Sysmex optical platelet volume indicator (PLT-F-Y) reliability. Finally, four cases of neonatal sepsis were examined to determine the correlation between PLT-F-Y and neonatal sepsis. Results In neonates with infections, 24.67% of MPV data did not accurately reflect platelet volume, and this issue was not confined to cases with low platelet counts. The PLT-F-Y indicator demonstrated superior accuracy in measuring platelet volume, with a reference range of approximately 42.6-64.2 MFI for neonates. Additionally, PLT-F-Y correlated with the progression of neonatal sepsis. Conclusion MPV is not a “perfect” indicator for newborns, whereas PLT-F-Y may serve as a potential better alternative. Health sciences/Diseases/Infectious diseases/Neonatal sepsis Health sciences/Medical research/Study design/Clinical trials Figures Figure 1 Figure 2 Figure 3 Figure 4 Introduction Sepsis is a systemic inflammatory response syndrome caused by pathogenic microorganisms such as bacteria. Critically ill patients often experience insufficient organ perfusion in addition to systemic inflammatory response and primary infectious lesions [1] . With over 18 million severe sepsis cases globally each year, and an annual rise of 1.5%-8.0%, the condition remains highly prevalent [2] . In China, prospective multicenter research reported a sepsis incidence of 77.6% (843/1,087 cases), and a septic shock rate of 38.7% (423/1,087 cases) [3] . Due to undeveloped immune systems of newborns, neonatal sepsis (NS) poses higher risks, particularly among very low birth weight infants and premature infants, ranging from 1 to 10 in every 1,000 neonates and 1% to 70%, respectively [4] . Confirmation of NS typically relies on body fluid cultivation, which is time-consuming and prone to false negatives, limiting its clinical utility [5] . Other diagnostic methods include white blood cell counting and inflammatory markers such as C-reaction protein (CRP). While CRP is effective for ruling out infections, it has limited sensitivity in the early stages of infection [6] . Platelet-related parameters in complete blood count, such as platelet (PLT) count, mean platelet volume (MPV), and plateletcrit (PCT), are measured using the Sysmex XN9000 analyzer [7] . Previous studies have reported a close relationship between MPV and NS, with MPV potentially indicating the occurrence, progression, and recovery of the condition [8] . As NS worthens, platelet volume increases. However, MPV is not an ideal marker due to limitations with traditional impedance method. On blood analyzer, traditional impedance method may misclassify small red blood cells (RBCs), RBC debris, and varying-sized platelets, leading to inaccurate MPV measurement [9] . In neonates, Capillary blood and the high production of macroplatelets during infections further complicate accurate MPV measurement. Our study of 1,070 infectious newborns found that MPV could not be measured in 24.67% of cases, with alarm information in PLT parameters indicating unavoidable issues. Of 479 cases with undetermined MPV values, 76 had “PLT aggregation”, 118 had “thrombocytopenia” and 285 had “unequal size of RBC” (Table 1), with some histograms showing alarms despite MPV values, which were unreliable. These findings highlight the limitations of current MPV detection methods and suggest a need for more reliable approaches for measuring neonatal platelet volume. Since 2000s, a novel method for measuring PLT count, known as Fluorescence PLT (PLT-F), has been invented and applied on Sysmex XN9000 blood analyzer. This technique utilizes a new fluorescent dye with high specificity, staining only platelets and minimizing interference from reticulocytes and erythrocytes [10] . The platelet count is still determined using flow cytometry, where the X-axis of PLT-F histogram represents side scatter (SSC), and the Y-axis represents forward scattered light (FSC). Since FSC reflects particle volume, we are wondering whether the Y-axis value of PLT-F histogram (PLT-F-Y) can serve as an indicator of platelet volume and aid in predicting the onset, progression, and recovery of NS. Results 1. Normal reference range of neonatal PLT-F-Y was established. According to the guidance of the China National Accreditation Service for Conformity Assessment, 240infection-free neonates were involved in this establishment. Half of them were boys while others were girls. The reference range for boy neonates was 41.8-64.8 MFI, and for girl neonates was 42.8-63.5 MFI. No significant gender differences were found (P=0.46) (Table 2). Thus, the data were combined, yielding a reference range of 42.6-64.2 MFI for neonates (Table 3). 2.Values of PLT-F-Y had a good correlation with those of MPV. A total of 200 neonatal blood samples were analyzed to ensure normal histogram distributions. The correlation between the traditional MPV measurement and the newly established PLT-F-Y method was assessed using paired T-test. Results showed that the correlation coefficient was 0.942, which indicated a strong relationship between PLT-F-Y and MPV when histograms were normal. This suggests that PLT-F-Y may serve as a viable alternative for MPV determination [11] . 3. There was a correlation between PLT-F-Y and neonatal sepsis. In cases of neonatal sepsis, different stages of the disease were monitered during hospitalization. Weekly measurements of MPV, PLT-F-Y, and CRP were taken. A strong correlation was observed between PLT-F-Y values and the severity of neonatal sepsis. PLT-F-Y values increased with worsening infection severity and decreases as recovery progressed, aligning with previous studies (Fig.1) [8] . These results indicate that PLT-F-Y closely correlates with the stages of NS. In addition, blood samples were collected from neonates without sepsis to serve as a control group, while neonates with NS were designated as experimental group. Measurements of MPV and PLT-F-Y were taken for both groups. Compared to experimental group, values of PLT-F-Y were lower in control group, which was consistent with MPV changing trend (Fig.2). Both PLT-F-Y and MPV were effective indicators for predicting and monitoring neonatal sepsis. However, there was a significant issue with MPV detection, with a 40% failure rate (Table 4). This suggests that PLT-F-Y may provide a more stable and reliable measurement. We investigated whether PLT-F-Y could predict the prognosis in patients with NS by comparing values in discharge and during follow-up visits. Our analysis revealed that patients with higher PLT-F-Y values at discharge had more frequent follow-up visits compared to those with lower PLT-F-Y values (Fig. 3, P <0.05). Unfortunately, a patient with persistently high PLT-F-Y levels ultimately passed away, suggesting that elevated PLT-F-Y level is associated with poor prognosis. These findings indicate that PLT-F-Y is a valuable indicator for predicting the prognosis of NS. 4. Observation of platelet sizes in different stages Blood samples from the “before treatment”, “in treatment” and “post-treatment” stages were collected. Smears were prepared, stained by Wright-Giemsa method, and examined with an automatic smear. Results showed that PLT sizes were larger before treatment. As treatment progressed, platelet volumes decreased, confirming that PLT volume reduced with the improvement of NS (Fig.4). Discussion Neonatal sepsis is a critical condition that poses a severe threat to newborns, making early assessment essential. Although there are several diagnostic methods for neonatal sepsis, many are time-consuming [2] . Mean platelet volume is fundamental indicator in blood routine test and has been shown to correlate well with neonatal sepsis. Previous research indicates a significant increase in MPV values in infants with sepsis [12] , suggesting that MPV may be a potential indicator for predicting the disease. However, MPV measurements can be unreliable due to factors such as uneven red blood cell sizes, the presence of immature red blood cells, or severe infection, which may interfere with accurate readings by blood analyzers. This underscores the need for alternative assessment method. The PLT-F-Y channel on the Sysmex XN9000 represents a novel approach for PLT determination, utilizing nucleic acid fluorescence staining to specifically differentiate platelets from other blood components. This method provides a scatter diagram on the analyzer, where the Y-axis is the set of forward scattered light, reflecting the average size of PLT [13] . Given this, PLT-F-Y values could potentially serve as an indicator for measuring MPV. To determine whether the value of PLT-F-Y was increasing or decreasing, a normal range of PLT-F-Y was established. Our study demonstrated that as the severity of infection worsened, value increased. This change can be attributed to the alterations in the coagulation cascade characteristic of sepsis. During sepsis, multiple pro- and anti-inflammatory cytokines are released, which can lead to thrombus formation and the subsequent depletion of fibrinolytic factors and fibrinogen, resulting in further platelet destruction [14] . Additionally, P-selectin, which is expressed on the surface of platelets during systemic inflammation, enhances platelet adhesion to white blood cells and promotes platelet aggregation [15] . In neonatal sepsis, platelet depletion and thrombus formation due to active endothelium contribute to thrombocytopenia [16] . Meanwhile, C-reactive protein, which peaks around 50 hours, aids in complement binding to foreign or damaged cells, playing a role in the inflammatory response. Although a non-specific marker, CRP can be a help in diagnosing sepsis, which is consistent with our findings [17] . Furthermore, Platelet activation is a significant physiological feature of NS. The increased production of young, larger platelets in the bone marrow leads to elevated PLT-F-Y values on the Sysmex XN9000, indicating its potential to predict the onset and progression of NS. As mentioned above, MPV measurements in neonates can sometimes be challenging in our laboratory. One reason is the sample type; neonatal samples are often collected from capillary blood, which can be contaminated with tissue fluid due to compression. This contamination may lead the analyzer to misidentify tissue fluid components as platelets, thus affecting the accuracy of platelet-related indicators like MPV [18] . Additionally, anemia in neonates can further impact MPV readings. Overall, multiple factors can influence the accuracy of MPV detection. The prognosis of NS is a critical concern for clinicians. Our study found that patients with higher PLT-F-Y values at discharge required more frequent follow-up visits, and a patient with persistently high PLT-F-Y levels unfortunately passed away. This observation aligns with previous research indicating that more severe NS is associated with higher MPV values. Therefore, PLT-F-Y may be able to provide a valuable prognostic indicator. If a patient’s PLT-F-Y value exceeds the reference upper limit at discharge, clinician should exercise heighted vigilance. Overall, platelet volume appears to have a strong correlation with the prognosis of NS. In our study, we noted an unusual case where, despite the progression of sepsis and consistently low platelet counts on different days, values of MPV remained within the normal range. Interestingly, the PLT-F-Y values were consistent with the MPV values. As the CRP values decreased, PLT-F-Y and MPV values elevated. We hypothesized that after the resolution of infection, the platelet production function in the bone marrow recovered well, leading to the recovery of PLT count, resulting in the increase of MPV. The study still has some limitations. Firstly, observational studies are influenced by confounding variables, which may affect true overall effect. Secondly, there is an incomplete data on some patients’ treatment processes, thus limiting our ability to further track the mortality and recurrence rates. Lastly, relationship between PLT-F-Y and other infectious diseases may be discussed in the future. Methods 1. Establishment of a normal reference range for PLT-F-Y in newborns According to Reference intervals of blood cell analysis in children (WS/T 779-2021), Peripheral blood samples of 285 newborns without infections under 28 days old were collected. PLT counts were examined using the PLT-F channel on Sysmex XN9000 blood analyzer (Sysmex, Japan). The Y-axis values of the PLT-F histogram were recorded and analyzed using SPSS statistics to determine the normal reference range. The inclusion criteria for normal newborns were as follows: ① full-term infants without infections or hematological diseases, ② white blood cell counts, hemoglobin levels and platelet counts within normal ranges, ③ MPV within the normal range and no triggering of histogram alarm. This research involving human subjects adhered to all relevant national regulations, institutional policies and was conducted in accordance with the principles of the Helsinki Declaration (as revised in 2008). The study was approved by the Biomedical Ethics Committee of West China Second University Hospital. Informed consent was obtained from all subjects and their legal guardians. 2. Verify the relationship between PLT-F-Y and NS Neonates with sepsis were grouped as the “sepsis” group, while a matching number of healthy neonates served as control group. Blood samples were collected at various stages of neonatal sepsis and from normal infantes at the same time. PLT counts and PLT-F-Y values were examined using the PLT-F channel. In the meantime, C-reaction protein concentrations were also assessed. GraphPad prism 9 was used to analyze the relationship among these metrics. 3. PLT size observation by an automatic smear reader Peripheral blood smears of collected blood samples were prepared using an automatic blood smear preparer (SP-50, Sysmex). These smears were then examined with an automatic smear reader (DI-60, Sysmex), which captured images of platelets of varying sizes using its camera. Declarations Acknowledgements We thank Dr. Maoting Xie from Department of Research & Sciences (Sysmex) for supporting us with data export from Sysmex XN9000. Funding Statement This work was supported by Health Commission of Sichuan Province Medical Science and Technology Program (No.24QNMP025). Author Contributions Hao Yang conducted these experiments and wrote the manuscript, Jiqian Bao conducted the experiments, Siqi Guo and Jiajing He analyzed these data, Lei Ye collected blood samples, Yingjun Zhang and Qingkai Dai modified the manuscript, and Ge Zhang designed these experiments. Data Availability Statement The datasets generated and analyzed during the current study are available in supplementary files. Competing Interests Statement The authors declare no competing interests. Ethical Approval and Informed Consent Research involving human subjects complied with all relevant national regulations, institutional policies, and is in accordance with the tenets of the Helsinki Declaration (as revised in 2008). Research has been approved by the Biomedical Ethics Committee of West China Second University Hospital. Informed consent was obtained from all subjects and their legal guardians. References Kellum, J. A., Formeck, C. L., Kernan, K. F., Gómez, H. & Carcillo, J. A. Subtypes and Mimics of Sepsis. Crit Care Clin 38 , 195-211, doi:10.1016/j.ccc.2021.11.013 (2022). Celik, I. H., Hanna, M., Canpolat, F. E. & Mohan, P. Diagnosis of neonatal sepsis: the past, present and future. Pediatr Res 91 , 337-350, doi:10.1038/s41390-021-01696-z (2022). Cao, Y. et al. Assessment of Neonatal Intensive Care Unit Practices, Morbidity, and Mortality Among Very Preterm Infants in China. JAMA Netw Open 4 , e2118904, doi:10.1001/jamanetworkopen.2021.18904 (2021). Yadav, P. & Yadav, S. K. Progress in Diagnosis and Treatment of Neonatal Sepsis: A Review Article. JNMA J Nepal Med Assoc 60 , 318-324, doi:10.31729/jnma.7324 (2022). Gopal, N. et al. Advancement in biomarker based effective diagnosis of neonatal sepsis. Artif Cells Nanomed Biotechnol 51 , 476-490, doi:10.1080/21691401.2023.2252016 (2023). Ruan, L. et al. The combination of procalcitonin and C-reactive protein or presepsin alone improves the accuracy of diagnosis of neonatal sepsis: a meta-analysis and systematic review. Crit Care 22 , 316, doi:10.1186/s13054-018-2236-1 (2018). Dixon, L. R. The complete blood count: physiologic basis and clinical usage. J Perinat Neonatal Nurs 11 , 1-18, doi:10.1097/00005237-199712000-00003 (1997). Milas, G. P., Karageorgiou, V. & Bellos, I. Mean platelet volume and neonatal sepsis: a systematic review and meta-analysis of diagnostic accuracy. J Matern Fetal Neonatal Med 35 , 5324-5336, doi:10.1080/14767058.2021.1879039 (2022). Park, M. J. et al. The relationship between iron parameters and platelet parameters in women with iron deficiency anemia and thrombocytosis. Platelets 24 , 348-351, doi:10.3109/09537104.2012.699641 (2013). Kim, H. et al. Performance of Platelet Counting in Thrombocytopenic Samples: Comparison between Mindray BC-6800Plus and Sysmex XN-9000. Diagnostics (Basel) 12 , doi:10.3390/diagnostics12010068 (2021). Schober, P., Boer, C. & Schwarte, L. A. Correlation Coefficients: Appropriate Use and Interpretation. Anesth Analg 126 , 1763-1768, doi:10.1213/ane.0000000000002864 (2018). Hanaganahalli, S. B. et al. Is MPV a Predictive Marker for Neonatal Sepsis? A Pilot Study. J Pediatr Hematol Oncol 40 , 548-552, doi:10.1097/mph.0000000000001272 (2018). Chen, H. T., Fu, L. M., Huang, H. H., Shu, W. E. & Wang, Y. N. Particles small angle forward-scattered light measurement based on photovoltaic cell microflow cytometer. Electrophoresis 35 , 337-344, doi:10.1002/elps.201300189 (2014). Akhmaltdinova, L. et al. Influence of Pathogen Type on Neonatal Sepsis Biomarkers. Int J Inflam 2021 , 1009231, doi:10.1155/2021/1009231 (2021). Tunjungputri, R. N. et al. Higher platelet reactivity and platelet-monocyte complex formation in Gram-positive sepsis compared to Gram-negative sepsis. Platelets 28 , 595-601, doi:10.1080/09537104.2016.1252837 (2017). Iba, T. & Levy, J. H. Inflammation and thrombosis: roles of neutrophils, platelets and endothelial cells and their interactions in thrombus formation during sepsis. J Thromb Haemost 16 , 231-241, doi:10.1111/jth.13911 (2018). Mair, R. J., Joy, A. H., Finney, H. & Weaver, A. Creating an algorithm for requesting C-reactive protein in the emergency department. Eur J Emerg Med 17 , 125-126, doi:10.1097/MEJ.0b013e3283366ceb (2010). Surma, M., Sawicki, T., Piskuła, M. & Wiczkowski, W. Relationship between the Consumption of Fermented Red Beetroot Juice and Levels of Perfluoroalkyl Substances in the Human Body's Fluids and Blood Parameters. Int J Mol Sci 24 , doi:10.3390/ijms241813956 (2023). Tables Table 1 Reasons why MPV cannot be detected. Erythrocyte effect was the most common. Instrument warning Case quantity Proportion Total amount Platelet Aggregation 76 15.87% 479 Low platelet count 118 24.64% Erythrocyte effect 285 59.49% Table 2 Both sets of data were normally distributed. There was no significance between reference ranges of two genders. Gender Case quantity Normal distribution test (Kolmogorov Test) Reference range Significance PLT-F-Y MPV P>0.05 Male neonates 147 P>0.05 41.8-64.8 9.0-12.9 Female neonates 137 P>0.05 43.8-63.5 9.2-12.5 Table 3 This set of data was normally distributed. The reference ranges of PLT-F-Y and MPV were successfully obtained. Object Case quantity Normal distribution test (Kolmogorov Test) Reference range PLT-F-Y MPV Neonates 284 P>0.05 42.6-64.2 9.2-12.8 Table 4 Comparison of the probability that two indicators cannot be detected in the four cases. The proportion of the former was much higher than the latter. PLT-F-Y was always detectable on Sysmex XN-9000. Indicator Having results No result Proportion (No result) MPV 23 16 41.02% PlT-F-Y 39 0 0.00% Additional Declarations No competing interests reported. Supplementary Files Dataofcollectedpatients.xlsx Dataofneonates.xlsx ReasonswhyMPVundetermined.xlsx Cite Share Download PDF Status: Posted Version 1 posted You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-5332746","acceptedTermsAndConditions":true,"allowDirectSubmit":true,"archivedVersions":[],"articleType":"Article","associatedPublications":[],"authors":[{"id":383264292,"identity":"d6774f76-611a-4eff-b6cf-6cfd231834a0","order_by":0,"name":"Hao Yang","email":"","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":false,"prefix":"","firstName":"Hao","middleName":"","lastName":"Yang","suffix":""},{"id":383264293,"identity":"60bf3744-4680-4778-aa90-1073241d1883","order_by":1,"name":"Jiqian Bao","email":"","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":false,"prefix":"","firstName":"Jiqian","middleName":"","lastName":"Bao","suffix":""},{"id":383264294,"identity":"54e4a897-f351-48bb-9703-10d640cd472f","order_by":2,"name":"Siqi Guo","email":"","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":false,"prefix":"","firstName":"Siqi","middleName":"","lastName":"Guo","suffix":""},{"id":383264295,"identity":"3fa24af8-2e79-4f13-996a-e234ce67c0d5","order_by":3,"name":"Jiajing He","email":"","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":false,"prefix":"","firstName":"Jiajing","middleName":"","lastName":"He","suffix":""},{"id":383264296,"identity":"93540c28-c537-44f4-afad-6e18191f2ac6","order_by":4,"name":"Lei Ye","email":"","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":false,"prefix":"","firstName":"Lei","middleName":"","lastName":"Ye","suffix":""},{"id":383264297,"identity":"58a7a736-2cce-46ec-b672-6dbd4169aa18","order_by":5,"name":"Yingjun Zhang","email":"","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":false,"prefix":"","firstName":"Yingjun","middleName":"","lastName":"Zhang","suffix":""},{"id":383264298,"identity":"2086023b-df5a-47bc-912c-e5da5222d11f","order_by":6,"name":"Qingkai Dai","email":"","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":false,"prefix":"","firstName":"Qingkai","middleName":"","lastName":"Dai","suffix":""},{"id":383264299,"identity":"9788624d-df3c-44e8-addc-bff4b151ba10","order_by":7,"name":"Ge Zhang","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAu0lEQVRIiWNgGAWjYBACNvbmAwcS/7DV9xOthY/nWOKBjw18jDMbiNUiJ5GjfHBmgxzjhgNEO4znDMNh3h1mzMbHkzcw/KjYRoQW9t4Dh3nPpLGZnXlWwNhz5jYxtpxLOMzDdozH7EaOATNjGzFaJHIMgFr+SxjPIEXLwZltbAYGEkRr4TmWcODDGbYECaBfDhLlF/n25sMfEirYEvjbkzc++FFBhBYkkGBwgCT1YC2k6hgFo2AUjIIRAgC1xkCi3emnNgAAAABJRU5ErkJggg==","orcid":"","institution":"West China Second University Hospital, Sichuan University Key Laboratory of Birth Defects and Related Diseases of Women and Children, Sichuan University","correspondingAuthor":true,"prefix":"","firstName":"Ge","middleName":"","lastName":"Zhang","suffix":""}],"badges":[],"createdAt":"2024-10-25 13:38:17","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-5332746/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-5332746/v1","draftVersion":[],"editorialEvents":[],"editorialNote":"","failedWorkflow":false,"files":[{"id":71564521,"identity":"90201f08-df8e-4148-ac0e-fa60381819be","added_by":"auto","created_at":"2024-12-16 17:24:19","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":716332,"visible":true,"origin":"","legend":"\u003cp\u003eFour cases of neonatal sepsis were collected. PLT-F-Y and CRP showed the same trend of change. As the value of CRP increased, PLT-F-Y increased. As the condition gradually improved, both CRP and PLT-F-Y decreased simultaneously.\u003c/p\u003e","description":"","filename":"Figure1.png","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/4c9a321c40817c33e13b8a2f.png"},{"id":71565233,"identity":"5eead4b5-cd17-4caa-aa7e-f4d37b47ae75","added_by":"auto","created_at":"2024-12-16 17:32:19","extension":"png","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":312345,"visible":true,"origin":"","legend":"\u003cp\u003eComparison of patients and control group in values of PLT-F-Y and MPV. Values of PLT-F-Y and MPV were significantly higher in patient group.\u003c/p\u003e","description":"","filename":"Figure2.png","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/d60644025d190f66ce5cec44.png"},{"id":71564526,"identity":"48d90456-e8c0-4326-b98c-67d7caf06a43","added_by":"auto","created_at":"2024-12-16 17:24:19","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":254815,"visible":true,"origin":"","legend":"\u003cp\u003eRelationship between PLT-F-Y and prognostic visits. The higher the PLT-F-Y value at discharge was the more prognostic visit times patient suffered.\u003c/p\u003e","description":"","filename":"Figure3.png","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/c0022c3e60768869ba0a81f6.png"},{"id":71564525,"identity":"275103c5-bd89-4dca-9059-051086f92b44","added_by":"auto","created_at":"2024-12-16 17:24:19","extension":"png","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":7131894,"visible":true,"origin":"","legend":"\u003cp\u003ePLT size observation at different stages of neonatal sepsis. As the teeatment progressed, the volume of PLT decreased from large to normal.\u003c/p\u003e","description":"","filename":"Figure4.png","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/215c4e0cd7e000b4c97a33a4.png"},{"id":76188052,"identity":"9dc3ed87-52d9-4872-a0ba-73d49cac2964","added_by":"auto","created_at":"2025-02-13 08:54:48","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":15360357,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/4c2959a4-1b89-4f32-a746-defac65f4b5c.pdf"},{"id":71564520,"identity":"fc3a96dc-2420-4056-b352-266ef0247df7","added_by":"auto","created_at":"2024-12-16 17:24:19","extension":"xlsx","order_by":0,"title":"","display":"","copyAsset":false,"role":"supplement","size":26603,"visible":true,"origin":"","legend":"","description":"","filename":"Dataofcollectedpatients.xlsx","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/e3d19de8f1c8a0ff793fceea.xlsx"},{"id":71564522,"identity":"2d6b8128-052d-4419-886c-02b5ddbfa4f1","added_by":"auto","created_at":"2024-12-16 17:24:19","extension":"xlsx","order_by":1,"title":"","display":"","copyAsset":false,"role":"supplement","size":20941,"visible":true,"origin":"","legend":"","description":"","filename":"Dataofneonates.xlsx","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/a40404fbda264c92512565d9.xlsx"},{"id":71565234,"identity":"1a8aecda-41e4-435e-9400-177a423fed24","added_by":"auto","created_at":"2024-12-16 17:32:19","extension":"xlsx","order_by":2,"title":"","display":"","copyAsset":false,"role":"supplement","size":145979,"visible":true,"origin":"","legend":"","description":"","filename":"ReasonswhyMPVundetermined.xlsx","url":"https://assets-eu.researchsquare.com/files/rs-5332746/v1/74a6c1f3499c74186ad3f756.xlsx"}],"financialInterests":"No competing interests reported.","formattedTitle":"MPV vs. Optical Platelet Volume Measurement: Which Is a Better Indicator for Neonatal Sepsis?","fulltext":[{"header":"Introduction","content":"\u003cp\u003eSepsis is a systemic inflammatory response syndrome caused by pathogenic microorganisms such as bacteria. Critically ill patients often experience insufficient organ perfusion in addition to systemic inflammatory response and primary infectious lesions\u003csup\u003e[1]\u003c/sup\u003e. With over 18 million severe sepsis cases globally each year, and an annual rise of 1.5%-8.0%, the condition remains highly prevalent\u003csup\u003e[2]\u003c/sup\u003e. In China, prospective multicenter research reported a sepsis incidence of 77.6% (843/1,087 cases), and a septic shock rate of 38.7% (423/1,087 cases)\u003csup\u003e[3]\u003c/sup\u003e. Due to undeveloped immune systems of newborns, neonatal sepsis (NS) poses higher risks, particularly among very low birth weight infants and premature infants, ranging from 1 to 10 in every 1,000 neonates and 1% to 70%, respectively\u003csup\u003e[4]\u003c/sup\u003e.\u003c/p\u003e\n\u003cp\u003eConfirmation of NS typically relies on body fluid cultivation, which is time-consuming and prone to false negatives, limiting its clinical utility\u003csup\u003e[5]\u003c/sup\u003e. Other diagnostic methods include white blood cell counting and inflammatory markers such as C-reaction protein (CRP). While CRP is effective for ruling out infections, it has limited sensitivity in the early stages of infection\u003csup\u003e[6]\u003c/sup\u003e.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003ePlatelet-related parameters in complete blood count, such as platelet (PLT) count, mean platelet volume (MPV), and plateletcrit (PCT), are measured using the Sysmex XN9000 analyzer\u003csup\u003e[7]\u003c/sup\u003e. Previous studies have reported a close relationship between MPV and NS, with MPV potentially indicating the occurrence, progression, and recovery of the condition\u003csup\u003e[8]\u003c/sup\u003e. As NS worthens, platelet volume increases. However, MPV is not an ideal marker due to limitations with traditional impedance method. On blood analyzer, traditional impedance method may misclassify small red blood cells (RBCs), RBC debris, and varying-sized platelets, leading to inaccurate MPV measurement\u003csup\u003e[9]\u003c/sup\u003e. In neonates, Capillary blood and the high production of macroplatelets during infections further complicate accurate MPV measurement.\u0026nbsp;Our study of 1,070 infectious newborns found that MPV could not be measured in 24.67% of cases, with alarm information in PLT parameters indicating unavoidable issues. Of 479 cases with undetermined MPV values, 76 had \u0026ldquo;PLT aggregation\u0026rdquo;, 118 had \u0026ldquo;thrombocytopenia\u0026rdquo; and 285 had \u0026ldquo;unequal size of RBC\u0026rdquo; (Table 1), with some histograms showing alarms despite MPV values, which were unreliable.\u0026nbsp;These findings highlight the limitations of current MPV detection methods and suggest a need for more reliable approaches for measuring neonatal platelet volume.\u003c/p\u003e\n\u003cp\u003eSince 2000s, a novel method for measuring PLT count, known as Fluorescence PLT (PLT-F), has been invented and applied on Sysmex XN9000 blood analyzer. This technique utilizes a new fluorescent dye with high specificity, staining only platelets and minimizing interference from reticulocytes and erythrocytes\u003csup\u003e[10]\u003c/sup\u003e. The platelet count is still determined using flow cytometry, where the X-axis of PLT-F histogram represents side scatter (SSC), and the Y-axis represents forward scattered light (FSC). Since FSC reflects particle volume, we are wondering whether the Y-axis value of PLT-F histogram (PLT-F-Y) can serve as an indicator of platelet volume and aid in predicting the onset, progression, and recovery of NS.\u003c/p\u003e"},{"header":"Results","content":"\u003cp\u003e1. \u0026nbsp;Normal reference range of neonatal PLT-F-Y was established.\u003c/p\u003e\n\u003cp\u003eAccording to the guidance of the China National Accreditation Service for Conformity Assessment, 240infection-free neonates were involved in this establishment. Half of them were boys while others were girls. The reference range for boy neonates was 41.8-64.8 MFI, and for girl neonates was 42.8-63.5 MFI.\u0026nbsp;No significant gender differences were found (P=0.46) (Table 2). Thus, the data were combined, yielding a reference range of 42.6-64.2 MFI for neonates (Table 3).\u003c/p\u003e\n\u003cp\u003e2.Values of PLT-F-Y had a good correlation with those of MPV.\u003c/p\u003e\n\u003cp\u003eA total of 200 neonatal blood samples were analyzed to ensure normal histogram distributions. The correlation between the traditional MPV measurement and the newly established PLT-F-Y method was assessed using paired T-test. Results showed that the correlation coefficient was 0.942, which indicated a strong relationship between PLT-F-Y and MPV when histograms were normal. This suggests that PLT-F-Y may serve as a viable alternative for MPV determination\u003csup\u003e[11]\u003c/sup\u003e.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003e3. There was a correlation between PLT-F-Y and neonatal sepsis.\u003c/p\u003e\n\u003cp\u003eIn cases of neonatal sepsis, different stages of the disease were monitered during hospitalization. Weekly measurements of MPV, PLT-F-Y, and CRP were taken. A strong correlation was observed between PLT-F-Y values and the severity of neonatal sepsis. PLT-F-Y values increased with worsening infection severity and decreases as recovery progressed, aligning with previous studies (Fig.1)\u003csup\u003e[8]\u003c/sup\u003e. These results indicate that PLT-F-Y closely correlates with the stages of NS.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eIn addition, blood samples were collected from neonates without sepsis to serve as a control group, while neonates with NS were designated as experimental group. Measurements of MPV and PLT-F-Y were taken for both groups. Compared to experimental group, values of PLT-F-Y were lower in control group, which was consistent with MPV changing trend (Fig.2). Both PLT-F-Y and MPV were effective indicators for predicting and monitoring neonatal sepsis. However, there was a significant issue with MPV detection, with a 40% failure rate (Table 4). This suggests that PLT-F-Y may provide a more stable and reliable measurement.\u003c/p\u003e\n\u003cp\u003eWe investigated whether PLT-F-Y could predict the prognosis in patients with NS by comparing values in discharge and during follow-up visits. Our analysis revealed that patients with higher PLT-F-Y values at discharge had more frequent follow-up visits compared to those with lower PLT-F-Y values (Fig. 3, \u003cem\u003eP\u003c/em\u003e\u0026lt;0.05). Unfortunately, a patient with persistently high PLT-F-Y levels ultimately passed away, suggesting that elevated PLT-F-Y level is associated with poor prognosis. These findings indicate that PLT-F-Y is a valuable indicator for predicting the prognosis of NS.\u003c/p\u003e\n\u003cp\u003e4. Observation of platelet sizes in different stages\u003c/p\u003e\n\u003cp\u003eBlood samples from the \u0026ldquo;before treatment\u0026rdquo;, \u0026ldquo;in treatment\u0026rdquo; and \u0026ldquo;post-treatment\u0026rdquo; stages were collected. Smears were prepared, stained by Wright-Giemsa method, and examined with an automatic smear. Results showed that PLT sizes were larger before treatment. As treatment progressed, platelet volumes decreased, confirming that PLT volume reduced with the improvement of NS (Fig.4).\u003c/p\u003e"},{"header":"Discussion","content":"\u003cp\u003eNeonatal sepsis is a critical condition that poses a severe threat to newborns, making early assessment essential. Although there are several diagnostic methods for neonatal sepsis, many are time-consuming\u003csup\u003e[2]\u003c/sup\u003e. Mean platelet volume is fundamental indicator in blood routine test and has been shown to correlate well with neonatal sepsis. Previous research indicates a significant increase in MPV values in infants with sepsis\u003csup\u003e[12]\u003c/sup\u003e, suggesting that MPV may be a potential indicator for predicting the disease. However, MPV measurements can be unreliable due to factors such as uneven red blood cell sizes, the presence of immature red blood cells, or severe infection, which may interfere with accurate readings by blood analyzers. This underscores the need for alternative assessment method. The PLT-F-Y channel on the Sysmex XN9000 represents a novel approach for PLT determination, utilizing nucleic acid fluorescence staining to specifically differentiate platelets from other blood components. This method provides a scatter diagram on the analyzer, where the Y-axis is the set of forward scattered light, reflecting the average size of PLT\u003csup\u003e[13]\u003c/sup\u003e. Given this, PLT-F-Y values could potentially serve as an indicator for measuring MPV. To determine whether the value of PLT-F-Y was increasing or decreasing, a normal range of PLT-F-Y was established.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003e\u0026nbsp; \u0026nbsp; \u0026nbsp;Our study demonstrated that as the severity of infection worsened, value increased. This change can be attributed to the alterations in the coagulation cascade characteristic of sepsis. During sepsis, multiple pro- and anti-inflammatory cytokines are released, which can lead to thrombus formation and the subsequent depletion of fibrinolytic factors and fibrinogen, resulting in further platelet destruction\u003csup\u003e[14]\u003c/sup\u003e. Additionally, P-selectin, which is expressed on the surface of platelets during systemic inflammation, enhances platelet adhesion to white blood cells and promotes platelet aggregation\u003csup\u003e[15]\u003c/sup\u003e. In neonatal sepsis, platelet depletion and thrombus formation due to active endothelium contribute to thrombocytopenia\u003csup\u003e[16]\u003c/sup\u003e. Meanwhile, C-reactive protein, which peaks around 50 hours, aids in complement binding to foreign or damaged cells, playing a role in the inflammatory response. Although a non-specific marker, CRP can be a help in diagnosing sepsis, which is consistent with our findings\u003csup\u003e[17]\u003c/sup\u003e. Furthermore, Platelet activation is a significant physiological feature of NS. The increased production of young, larger platelets in the bone marrow leads to elevated PLT-F-Y values on the Sysmex XN9000, indicating its potential to predict the onset and progression of NS.\u003c/p\u003e\n\u003cp\u003eAs mentioned above, MPV measurements in neonates can sometimes be challenging in our laboratory. One reason is the sample type; neonatal samples are often collected from capillary blood, which can be contaminated with tissue fluid due to compression. This contamination may lead the analyzer to misidentify tissue fluid components as platelets, thus affecting the accuracy of platelet-related indicators like MPV\u003csup\u003e[18]\u003c/sup\u003e. Additionally, anemia in neonates can further impact MPV readings. Overall, multiple factors can influence the accuracy of MPV detection.\u003c/p\u003e\n\u003cp\u003eThe prognosis of NS is a critical concern for clinicians. Our study found that patients with higher PLT-F-Y values at discharge required more frequent follow-up visits, and a patient with persistently high PLT-F-Y levels unfortunately passed away. This observation aligns with previous research indicating that more severe NS is associated with higher MPV values. Therefore, PLT-F-Y may be able to provide a valuable prognostic indicator. If a patient\u0026rsquo;s PLT-F-Y value exceeds the reference upper limit at discharge, clinician should exercise heighted vigilance. Overall, platelet volume appears to have a strong correlation with the prognosis of NS.\u003c/p\u003e\n\u003cp\u003eIn our study, we noted an unusual case where, despite the progression of sepsis and consistently low platelet counts on different days, values of MPV remained within the normal range. Interestingly, the PLT-F-Y values were consistent with the MPV values. As the CRP values decreased, PLT-F-Y and MPV values elevated. We hypothesized that after the resolution of infection, the platelet production function in the bone marrow recovered well, leading to the recovery of PLT count, resulting in the increase of MPV.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eThe study still has some limitations. Firstly, observational studies are influenced by confounding variables, which may affect true overall effect. Secondly, there is an incomplete data on some patients\u0026rsquo; treatment processes, thus limiting our ability to further track the mortality and recurrence rates. Lastly, relationship between PLT-F-Y and other infectious diseases may be discussed in the future.\u0026nbsp;\u003c/p\u003e"},{"header":"Methods","content":"\u003cp\u003e1.\u0026nbsp; \u0026nbsp;Establishment of a normal reference range for PLT-F-Y in newborns\u003c/p\u003e\n\u003cp\u003eAccording to Reference intervals of blood cell analysis in children (WS/T 779-2021),\u0026nbsp;Peripheral blood samples of 285 newborns without infections under 28 days old were collected. PLT counts were examined using the PLT-F channel on Sysmex XN9000 blood analyzer (Sysmex, Japan). The Y-axis values of the PLT-F histogram were recorded and analyzed using SPSS statistics to determine the normal reference range.\u003c/p\u003e\n\u003cp\u003eThe inclusion criteria for normal newborns were as follows:\u003c/p\u003e\n\u003cp\u003e①\u0026nbsp;full-term infants without infections or hematological diseases,\u003c/p\u003e\n\u003cp\u003e②\u0026nbsp;white blood cell counts, hemoglobin levels and platelet counts within normal ranges,\u003c/p\u003e\n\u003cp\u003e③\u0026nbsp;MPV within the normal range and no triggering of histogram alarm.\u003c/p\u003e\n\u003cp\u003eThis research involving human subjects adhered to all relevant national regulations, institutional policies and was conducted in accordance with the principles of the Helsinki Declaration (as revised in 2008). The study was approved by the Biomedical Ethics Committee of West China Second University Hospital.\u0026nbsp;Informed consent was obtained from all subjects and their legal guardians.\u003c/p\u003e\n\u003cp\u003e2.\u0026nbsp; \u0026nbsp;Verify the relationship between PLT-F-Y and NS\u003c/p\u003e\n\u003cp\u003eNeonates with sepsis were grouped as the \u0026ldquo;sepsis\u0026rdquo; group, while a matching number of healthy neonates\u0026nbsp;served as control group. Blood samples were collected at various stages of neonatal sepsis and from normal infantes at the same time. PLT counts and PLT-F-Y values were examined using the PLT-F channel. In the meantime, C-reaction protein concentrations were also assessed. GraphPad prism 9 was used to analyze the relationship among these metrics.\u003c/p\u003e\n\u003cp\u003e3. PLT size observation by an automatic smear reader\u003c/p\u003e\n\u003cp\u003ePeripheral blood smears of collected blood samples were prepared using an automatic blood smear preparer (SP-50, Sysmex). These smears were then examined with an automatic smear reader (DI-60, Sysmex), which captured images of platelets of varying sizes using its camera.\u003c/p\u003e"},{"header":"Declarations","content":"\u003cp\u003eAcknowledgements\u003c/p\u003e\n\u003cp\u003eWe thank Dr. Maoting Xie from Department of Research \u0026amp; Sciences (Sysmex) for supporting us with data export from Sysmex XN9000.\u003c/p\u003e\n\u003cp\u003eFunding Statement\u003c/p\u003e\n\u003cp\u003eThis work was supported by Health Commission of Sichuan Province Medical Science and Technology Program (No.24QNMP025).\u003c/p\u003e\n\u003cp\u003eAuthor Contributions\u003c/p\u003e\n\u003cp\u003eHao Yang conducted these experiments and wrote the manuscript, Jiqian Bao conducted the experiments, Siqi Guo and Jiajing He analyzed these data, Lei Ye collected blood samples, Yingjun Zhang and Qingkai Dai modified the manuscript, and Ge Zhang designed these experiments.\u003c/p\u003e\n\u003cp\u003eData Availability Statement\u003c/p\u003e\n\u003cp\u003eThe datasets generated and analyzed during the current study are available in supplementary files.\u003c/p\u003e\n\u003cp\u003eCompeting Interests Statement\u003c/p\u003e\n\u003cp\u003eThe authors declare no competing interests.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eEthical Approval and Informed Consent\u003c/p\u003e\n\u003cp\u003eResearch involving human subjects complied with all relevant national regulations, institutional policies, and is in accordance with the tenets of the Helsinki Declaration (as revised in 2008). Research has been approved by the Biomedical Ethics Committee of West China Second University Hospital. Informed consent was obtained from all subjects and their legal guardians.\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\n \u003cli\u003eKellum, J. A., Formeck, C. L., Kernan, K. F., G\u0026oacute;mez, H. \u0026amp; Carcillo, J. A. Subtypes and Mimics of Sepsis. \u003cem\u003eCrit Care Clin\u003c/em\u003e \u003cstrong\u003e38\u003c/strong\u003e, 195-211, doi:10.1016/j.ccc.2021.11.013 (2022).\u003c/li\u003e\n \u003cli\u003eCelik, I. H., Hanna, M., Canpolat, F. E. \u0026amp; Mohan, P. Diagnosis of neonatal sepsis: the past, present and future. \u003cem\u003ePediatr Res\u003c/em\u003e \u003cstrong\u003e91\u003c/strong\u003e, 337-350, doi:10.1038/s41390-021-01696-z (2022).\u003c/li\u003e\n \u003cli\u003eCao, Y.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e Assessment of Neonatal Intensive Care Unit Practices, Morbidity, and Mortality Among Very Preterm Infants in China. \u003cem\u003eJAMA Netw Open\u003c/em\u003e \u003cstrong\u003e4\u003c/strong\u003e, e2118904, doi:10.1001/jamanetworkopen.2021.18904 (2021).\u003c/li\u003e\n \u003cli\u003eYadav, P. \u0026amp; Yadav, S. K. Progress in Diagnosis and Treatment of Neonatal Sepsis: A Review Article. \u003cem\u003eJNMA J Nepal Med Assoc\u003c/em\u003e \u003cstrong\u003e60\u003c/strong\u003e, 318-324, doi:10.31729/jnma.7324 (2022).\u003c/li\u003e\n \u003cli\u003eGopal, N.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e Advancement in biomarker based effective diagnosis of neonatal sepsis. \u003cem\u003eArtif Cells Nanomed Biotechnol\u003c/em\u003e \u003cstrong\u003e51\u003c/strong\u003e, 476-490, doi:10.1080/21691401.2023.2252016 (2023).\u003c/li\u003e\n \u003cli\u003eRuan, L.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e The combination of procalcitonin and C-reactive protein or presepsin alone improves the accuracy of diagnosis of neonatal sepsis: a meta-analysis and systematic review. \u003cem\u003eCrit Care\u003c/em\u003e \u003cstrong\u003e22\u003c/strong\u003e, 316, doi:10.1186/s13054-018-2236-1 (2018).\u003c/li\u003e\n \u003cli\u003eDixon, L. R. The complete blood count: physiologic basis and clinical usage. \u003cem\u003eJ Perinat Neonatal Nurs\u003c/em\u003e \u003cstrong\u003e11\u003c/strong\u003e, 1-18, doi:10.1097/00005237-199712000-00003 (1997).\u003c/li\u003e\n \u003cli\u003eMilas, G. P., Karageorgiou, V. \u0026amp; Bellos, I. Mean platelet volume and neonatal sepsis: a systematic review and meta-analysis of diagnostic accuracy. \u003cem\u003eJ Matern Fetal Neonatal Med\u003c/em\u003e \u003cstrong\u003e35\u003c/strong\u003e, 5324-5336, doi:10.1080/14767058.2021.1879039 (2022).\u003c/li\u003e\n \u003cli\u003ePark, M. J.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e The relationship between iron parameters and platelet parameters in women with iron deficiency anemia and thrombocytosis. \u003cem\u003ePlatelets\u003c/em\u003e \u003cstrong\u003e24\u003c/strong\u003e, 348-351, doi:10.3109/09537104.2012.699641 (2013).\u003c/li\u003e\n \u003cli\u003e Kim, H.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e Performance of Platelet Counting in Thrombocytopenic Samples: Comparison between Mindray BC-6800Plus and Sysmex XN-9000. \u003cem\u003eDiagnostics (Basel)\u003c/em\u003e \u003cstrong\u003e12\u003c/strong\u003e, doi:10.3390/diagnostics12010068 (2021).\u003c/li\u003e\n \u003cli\u003e Schober, P., Boer, C. \u0026amp; Schwarte, L. A. Correlation Coefficients: Appropriate Use and Interpretation. \u003cem\u003eAnesth Analg\u003c/em\u003e \u003cstrong\u003e126\u003c/strong\u003e, 1763-1768, doi:10.1213/ane.0000000000002864 (2018).\u003c/li\u003e\n \u003cli\u003e Hanaganahalli, S. B.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e Is MPV a Predictive Marker for Neonatal Sepsis? A Pilot Study. \u003cem\u003eJ Pediatr Hematol Oncol\u003c/em\u003e \u003cstrong\u003e40\u003c/strong\u003e, 548-552, doi:10.1097/mph.0000000000001272 (2018).\u003c/li\u003e\n \u003cli\u003e Chen, H. T., Fu, L. M., Huang, H. H., Shu, W. E. \u0026amp; Wang, Y. N. Particles small angle forward-scattered light measurement based on photovoltaic cell microflow cytometer. \u003cem\u003eElectrophoresis\u003c/em\u003e \u003cstrong\u003e35\u003c/strong\u003e, 337-344, doi:10.1002/elps.201300189 (2014).\u003c/li\u003e\n \u003cli\u003e Akhmaltdinova, L.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e Influence of Pathogen Type on Neonatal Sepsis Biomarkers. \u003cem\u003eInt J Inflam\u003c/em\u003e \u003cstrong\u003e2021\u003c/strong\u003e, 1009231, doi:10.1155/2021/1009231 (2021).\u003c/li\u003e\n \u003cli\u003e Tunjungputri, R. N.\u003cem\u003e\u0026nbsp;et al.\u003c/em\u003e Higher platelet reactivity and platelet-monocyte complex formation in Gram-positive sepsis compared to Gram-negative sepsis. \u003cem\u003ePlatelets\u003c/em\u003e \u003cstrong\u003e28\u003c/strong\u003e, 595-601, doi:10.1080/09537104.2016.1252837 (2017).\u003c/li\u003e\n \u003cli\u003e Iba, T. \u0026amp; Levy, J. H. Inflammation and thrombosis: roles of neutrophils, platelets and endothelial cells and their interactions in thrombus formation during sepsis. \u003cem\u003eJ Thromb Haemost\u003c/em\u003e \u003cstrong\u003e16\u003c/strong\u003e, 231-241, doi:10.1111/jth.13911 (2018).\u003c/li\u003e\n \u003cli\u003e Mair, R. J., Joy, A. H., Finney, H. \u0026amp; Weaver, A. Creating an algorithm for requesting C-reactive protein in the emergency department. \u003cem\u003eEur J Emerg Med\u003c/em\u003e \u003cstrong\u003e17\u003c/strong\u003e, 125-126, doi:10.1097/MEJ.0b013e3283366ceb (2010).\u003c/li\u003e\n \u003cli\u003e Surma, M., Sawicki, T., Piskuła, M. \u0026amp; Wiczkowski, W. Relationship between the Consumption of Fermented Red Beetroot Juice and Levels of Perfluoroalkyl Substances in the Human Body\u0026apos;s Fluids and Blood Parameters. \u003cem\u003eInt J Mol Sci\u003c/em\u003e \u003cstrong\u003e24\u003c/strong\u003e, doi:10.3390/ijms241813956 (2023).\u003c/li\u003e\n\u003c/ol\u003e"},{"header":"Tables","content":"\u003cp\u003eTable 1 Reasons why MPV cannot be detected. Erythrocyte effect was the most common.\u0026nbsp;\u003c/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"576\"\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eInstrument warning\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eCase quantity\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eProportion\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eTotal amount\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003ePlatelet Aggregation\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e76\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e15.87%\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd rowspan=\"3\" valign=\"top\"\u003e\n \u003cp\u003e479\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eLow platelet count\u0026nbsp;\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e118\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e24.64%\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eErythrocyte effect\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e285\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e59.49%\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003c/tbody\u003e\n\u003c/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c/p\u003e\n\u003cp\u003eTable 2 Both sets of data were normally distributed. There was no significance between reference ranges of two genders.\u003c/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eGender\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eCase quantity\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eNormal distribution test (Kolmogorov Test)\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd colspan=\"2\" valign=\"top\"\u003e\n \u003cp\u003eReference range\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eSignificance\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd colspan=\"3\" valign=\"top\"\u003e\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\u0026nbsp;\u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003ePLT-F-Y\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eMPV\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd rowspan=\"3\" valign=\"top\"\u003e\n \u003cp\u003eP\u0026gt;0.05\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eMale neonates\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e147\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eP\u0026gt;0.05\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e41.8-64.8\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e9.0-12.9\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eFemale neonates\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e137\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eP\u0026gt;0.05\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e43.8-63.5\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e9.2-12.5\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003c/tbody\u003e\n\u003c/table\u003e\n\u003cp\u003eTable 3 This set of data was normally distributed. The reference ranges of PLT-F-Y and MPV were successfully obtained.\u003c/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"562\"\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eObject\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eCase quantity\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eNormal distribution test (Kolmogorov Test)\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd colspan=\"2\" valign=\"top\"\u003e\n \u003cp\u003eReference range\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd colspan=\"3\" valign=\"top\"\u003e\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\u0026nbsp;\u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003ePLT-F-Y\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eMPV\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e\u0026nbsp;Neonates\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e284\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eP\u0026gt;0.05\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e42.6-64.2\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e9.2-12.8\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003c/tbody\u003e\n\u003c/table\u003e\n\u003cp\u003eTable 4 Comparison of the probability that two indicators cannot be detected in the four cases. The proportion of the former was much higher than the latter. PLT-F-Y was always detectable on Sysmex XN-9000.\u003c/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"568\"\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eIndicator\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eHaving results\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eNo result\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eProportion (No result)\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003eMPV\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e23\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e16\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e41.02%\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003ctr\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003ePlT-F-Y\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e39\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e0\u003c/p\u003e\n \u003c/td\u003e\n \u003ctd valign=\"top\"\u003e\n \u003cp\u003e0.00%\u003c/p\u003e\n \u003c/td\u003e\n \u003c/tr\u003e\n \u003c/tbody\u003e\n\u003c/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":true,"highlight":"","institution":"","isAcceptedByJournal":false,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true},"keywords":"","lastPublishedDoi":"10.21203/rs.3.rs-5332746/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-5332746/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003eObjective\u003c/p\u003e\n\u003cp\u003eTo evaluate the accuracy of mean platelet volume (MPV) testing in the neonatal population and assess the applicability of the optical platelet volume measurement method on Sysmex XN9000 in this demographic.\u003c/p\u003e\n\u003cp\u003eMethod\u003c/p\u003e\n\u003cp\u003eFrom June 2023 to June 2024, we analyzed complete blood count (CBC) data from 1070 neonates with infections to assess MPV testing reliability using instrument alerts and histograms. Additionally, 284 neonates without infections or hematologic diseases were included to evaluate the Sysmex optical platelet volume indicator (PLT-F-Y) reliability. Finally, four cases of neonatal sepsis were examined to determine the correlation between PLT-F-Y and neonatal sepsis.\u003c/p\u003e\n\u003cp\u003eResults\u003c/p\u003e\n\u003cp\u003eIn neonates with infections, 24.67% of MPV data did not accurately reflect platelet volume, and this issue was not confined to cases with low platelet counts. The PLT-F-Y indicator demonstrated superior accuracy in measuring platelet volume, with a reference range of approximately 42.6-64.2 MFI for neonates. Additionally, PLT-F-Y correlated with the progression of neonatal sepsis.\u003c/p\u003e\n\u003cp\u003eConclusion\u003c/p\u003e\n\u003cp\u003eMPV is not a “perfect” indicator for newborns, whereas PLT-F-Y may serve as a potential better alternative.\u003c/p\u003e","manuscriptTitle":"MPV vs. Optical Platelet Volume Measurement: Which Is a Better Indicator for Neonatal Sepsis?","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2024-12-16 17:24:14","doi":"10.21203/rs.3.rs-5332746/v1","editorialEvents":[{"type":"communityComments","content":0}],"status":"published","journal":{"display":true,"email":"[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"9ab72ff3-68f3-489d-b69d-a3d65d02acc1","owner":[],"postedDate":"December 16th, 2024","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"posted","subjectAreas":[{"id":40822002,"name":"Health sciences/Diseases/Infectious diseases/Neonatal sepsis"},{"id":40822003,"name":"Health sciences/Medical research/Study design/Clinical trials"}],"tags":[],"updatedAt":"2025-02-13T08:53:36+00:00","versionOfRecord":[],"versionCreatedAt":"2024-12-16 17:24:14","video":"","vorDoi":"","vorDoiUrl":"","workflowStages":[]},"version":"v1","identity":"rs-5332746","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-5332746","identity":"rs-5332746","version":["v1"]},"buildId":"qtupq5eGEP_6zYnWcrvyt","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2024) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00