Risk of Airway Fire with the use of KTP Laser and High Flow Humidified Oxygen Delivery in a Laryngeal Surgery Model | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Research Article Risk of Airway Fire with the use of KTP Laser and High Flow Humidified Oxygen Delivery in a Laryngeal Surgery Model Lucy Huang, Adam Badenoch, Marthinus Vermeulen, Shahid Ullah, and 3 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-926775/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 11 Jan, 2022 Read the published version in Scientific Reports → Version 1 posted 8 You are reading this latest preprint version Abstract Background Airway surgery presents a unique environment for operating room fire to occur. This study aims to explore the factors of combustion when using KTP laser with high flow oxygen in an ex-vivo model. Methods The variables tested were varying tissue type, tissue condition, oxygen concentration, laser setting, and smoke evacuation in a stainless-steel model. Outcome measures were time of lasing to the first spark and/or flame. A multivariate Cox proportional hazard model was used to determine the risk of spark and flame across the different risk factors. Results For every 10% increase in oxygen concentration above 60% the risk of flame increased by a factor of 2.3. Continuous laser setting at 2.6W increased the risk by a factor of 72.8. The risk of lasing adipose tissue is 7.3 times higher than that of muscle. Charred tissue increases the risk of flame by a factor of 92.8. Flame occurred without a preceding spark 93.6% of the time. Conclusions Using KTP laser in the pulsed mode with low wattages, minimising lasing time, reducing the oxygen concentration and avoiding lasing adipose or charred tissue produce a relatively low estimated risk of spark or flame. Other Public Policy Health Policy Anesthesiology & Pain Medicine THRIVE KTP laser airway fire high flow oxygen Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Introduction Operating-room airway fires are serious and potentially fatal complications but fortunately rare in otolaryngologic surgery 1 . Airway fires have been described during adenotonsillectomy, tracheostomy and endoscopic airway surgery 2 . The triad of essential elements required for an airway fire are oxygen, fuel, and an ignition source 3 . Oxygen is in abundance in a shared airway setting where it may be delivered via a facemask, traditional nasal cannulae, supraglottic jet ventilation, endotracheal tube, or high-flow nasal oxygen. The ignition source is usually from the heat generated from electrocautery devices or lasers. Potential fuel sources include endotracheal tubes (ETT), gauze, drapes and the eschar from charred tissue 4 . Transnasal humidified rapid insufflation ventilatory exchange (THRIVE) is a method of oxygenating patients in a shared airway setting by delivering oxygen at a high flow rate to the lungs without an endotracheal tube. It allows for an unobstructed surgical field and eliminates the endotracheal tube as a potential fuel for ignition. Nasal high-flow oxygen used for THRIVE usually delivers 100% oxygen, however devices incorporating oxygen-air blenders are now available to alter the oxygen concentration delivered. Reports of fires during the use of nasal high flow oxygen in conjunction with electrocautery and laser are also emerging 5 – 7 . The use of lasers in laryngeal surgery has increased over recent years, delivering targeted resection with improved haemostasis 8 . The traditionally used carbon dioxide (CO 2 ) laser has a wavelength of 10,600nm, which is strongly absorbed by water and tissue and is associated with most airway fire reports to date 3 , 9 , 10 . By contrast, Potassium-titanyl-phosphate (KTP) laser is a solid-state laser with a wavelength of 532nm, resulting in specific absorption of energy by oxyhaemoglobin in red blood cells, producing photoangiolysis of blood vessels at lower tissue temperature with less vaporisation 11 , 12 . These factors may theoretically reduce the risk of an airway fire when used in upper airway surgery, compared with the CO 2 laser. Studies examining the factors that contribute to the risk of airway fires in clinical practice have largely been conducted using the CO 2 laser 3,13−15 . The study by Roy et al. used a mannequin intubated with a laser safe ETT, demonstrating an immediate sustained fire when the CO 2 laser struck and perforated the ETT cuff. This occurred with oxygen concentration as low as 40% indicating that traditional methods of airway management with an ETT for upper airway laser use are not risk free 2 . Dhar et al studied CO 2 laser in combination with subglottic jet ventilation in a porcine model, identifying oxygen concentration, laser power and dry fuel source as independent risk factors for combustion 13 . A subsequent study by Stuermer et al. confirmed laser power and oxygen concentration as risk factors and identified tissue type (adipose, cartilage, muscle), tissue quality (fresh, charred) and the use of smoke evacuation as additional independent risk factors for combustion in an ex-vivo plexiglass model using CO 2 laser 3 . These two studies were conducted using non-humidified oxygen sources at flow rates significantly lower (jet ventilation at 2 bar and low flow rate at 10L/minute) than those generated when using THRIVE (70L/min) 3 , 13 . It is possible that 100% humidification of the gas mixture and the high flow rate provided by THRIVE reduces the risk of combustion 15 . There has been no study investigating the risk of KTP laser causing an airway fire despite its common use in laryngeal surgery. The aim of this study is to examine the factors associated with combustion when using KTP laser in combination with humidified high-flow nasal oxygen. We developed an ex-vivo model which is designed to simulate laryngeal surgery to facilitate risk prediction of spark and flame under clinically relevant conditions. Methods Human ethics was not required for this study as all experiments were performed using animal tissue (porcine muscle and adipose tissue) purchased from the local butcher. This study is listed on the Animal Register at Flinders University. The ex-vivo experiment took place in the operating theatre using standard anaesthetic and operating equipment. A model was designed by the Biomedical Engineering Department to simulate the upper airway, consisting of a cylindrical stainless-steel chamber (outer diameter: 10cm, inner diameter: 5cm, length: 32cm; Figure 1a and b). Positioned superiorly, are openings for the Optiflow TM nasal canula, KTP laser fibre holder, suction, endoscopic camera, and an oxygen sensor to verify precise tissue oxygen concentration at the point of lasing. A plastic covering was used to reduce oxygen loss and maximise oxygen concentration within the chamber. Inferiorly, positioned 25cm from the opening is a metal platform that holds the tissue being lasered (Figure 1c). The Aura XP Laser Therapy System TM (Boston Scientific) was used with EndoStat 0.4mm laser fibres, using a non-contact firing technique. Optiflow TM (Fisher & Paykel), incorporating an oxygen-air blender, was used to provide flow rates of 70L/minute (min), simulating THRIVE with the ability to alter the oxygen concentration. Porcine adipose and muscle tissue were used, as they represented the most and least flammable tissue type in the study performed by Stuermer et al 3 . The KTP laser settings were chosen based on clinical relevance (2.6W continuous, 5W continuous, 26W pulsed and 35W pulsed settings; pulsed setting set at 15 millisecond pulse width, 2 pulse per second). Lasing was performed on both charred and uncharred, adipose and muscle tissue with variable oxygen concentrations (30%, 40%, 50%, 60%, 70%, 80%, 90%), with and without smoke evacuation. Each piece of tissue was placed in a plastic bag and warmed using a water bath to 30°C. Charring of tissue was conducted using a kitchen blow torch to enable even charring on tissue surface (Figure 2). 100% humidification and gas flow rate at 70L/min were used in every instance. Each combination of variables was repeated at least five times to ensure reproducibility. If a flame occurred, oxygen was immediately reduced to 21% using the oxygen-air blender while maintaining 70L/min flow rates, which rapidly extinguished the flame. Example videos have been provided in Supplementary video 1 and 2. Outcome measures The outcomes were the occurrence of a spark and/or flame. Flame is considered the most important patient-centred outcome; however, sparks are often used clinically as a surrogate marker to indicate increased risk of flame if lasing continues, therefore spark and flame were modelled separately from the same data set. Time was measured from the start of lasing to the time to first spark/flame, or until 60 seconds. A 60 second cut off time was used, as lasing beyond 60 seconds is not clinically relevant. Statistical methods A multivariate Cox proportional hazard model was used to examine the risk of spark/flame across tissue-oxygen concentration, laser setting, tissue type, charring and smoke evacuation. Time to event was measured from the time of lasing onset to the time of spark/flame, experiments were censored at 60 seconds. As each combination of experimental conditions was repeated 5 times the models captured the mixed effect using shared frailty – the same random effect is shared by all repeated events within the same experimental group. The frailties are assumed to be gamma-distributed latent random effects that affect the hazard multiplicatively. The variables included in the final multivariate model were oxygen concentration, laser setting, tissue type and charring. The inclusion criterion was based on clinical importance, and statistical significance at P£0.20 from a univariate model. Variables tested experimentally and included in the univariate analyses were all previously identified as independent risk factors in previous studies using different laser types 3,15 . Smoke evacuation was subsequently excluded from the multivariable model based on non-significance in the univariate model. Additionally, re-inclusion of smoke evacuation into the final model did not result in a statistically significant association or significant change in the model coefficients. Proportional hazard assumption was tested by log-log plot of survival and Schoenfeld residuals and was found to be valid. Linear splines were employed to account for non-linearity of association between oxygen concentration and outcome hazard. The spline cut-off at 60% oxygen was selected based on it being an inflection point in the observed data and a judgement that this cut-off was clinically relevant in terms of the risk of hypoxia when THRIVE is used clinically. Cumulative hazard curves were evaluated by standard Nelson-Aalen cumulative hazard functions. The clinically relevant probabilities of spark or flame were established using the final multivariable Cox proportion hazard models by restricting the predictive model to 5 seconds of lasing (or time to event if <5 seconds) to facilitate a pragmatic and clinically relevant risk assessment. Probabilities were generated based on calculation of coefficients from the regression model and estimates of 5-second risk of spark or flame. In particular, the coefficient was multiplied by the value of the variable and then summed for each variable to get the scores. The baseline survival function was then exponentiated by the score and then subtracted from 1 to calculate the 5-second risk. Finally, the adjusted predictions were displayed after using a restricted cubic spline to account for non-linear relationships between oxygen concentration and the risk of spark or flame. Model diagnostics and goodness of fit were evaluated by Harrell's C concordance statistic. The two-sided test was performed for all analysis and the level of significance was set at p <0.05. Results The ex-vivo testing resulted in 2,182 firing episodes across a total of 224 combinations of variables. There were no missing data. Flames were preceded by sparks in 6.4% of instances and occurred without sparks 93.6% of the time. In those instances where sparks preceded flames the median (25th -75th percentiles) time difference between spark and flame was 19 (4–44) seconds. Notably, no sparks or flames were observed when laser firing was limited to 5 seconds at fresh tissue irrespective of oxygen concentration, laser setting or tissue type. Oxygen concentration, laser mode, tissue type, and tissue quality were all independent risk factors for spark and flame (Fig. 3 a-d). Smoke evacuation was not a significant predictor of spark nor flame in either the univariate or multivariate analyses and was therefore excluded from the final multivariable model (Fig. 3 e). Results of the final multivariable model for spark and flame are presented in (Fig. 4 ). The Harrell's C concordance statistic for the multivariable model was 0.91 for spark and 0.94 for flame. When compared with uncharred tissue, the risk (95% CI) of spark when lasing at charred tissue was increased by 34.9 (16.8–72.5) [p < 0.001] and the risk of flame increased by 92.8 (31.8-270.4) [p < 0.001] (Fig. 4 (b)). For oxygen concentration within the range 25–59%, the risk (95% CI) of spark increased by 3.9 (2.4–6.3) [p < 0.001] and flame increased by 6.6 (3.0-14.5) [p < 0.001] for every 10% increase in oxygen concentration. For oxygen concentration within the range 60–90%, the risk of spark increased by 1.8 (1.3–2.4) [p < 0.001] and flame increased by 2.3 (1.6–3.4) [p < 0.001] for every 10% increase in oxygen concentration. Compared with pulsed 26W (lowest power setting), pulsed 35W increased the risk (95% CI) of spark by 5.7 (2.0-15.7) [p < 0.01] and the risk of flame by 4.8 (1.2–18.6) (p < 0.05). The risk (95% CI) of spark at continuous 2.6W and 5W are increased by 28.8 (10.0-83.2) [p < 0.001)] and 48.6 (17.0-138.8) [p < 0.001] respectively. The risk (95% CI) of flame at continuous 2.6W and 5W are increased by 72.8 (17.6-300.5) (p < 0.001) and 47.1 (12.0-185.7) [p < 0.001] respectively. There was no statistically significant difference between the risk of spark or flame associated with 2.6W and 5W continuous settings when compared with each other. Compared with muscle, the risk (95% CI) of spark when lasing at adipose tissue is 7.3 (3.6–14.8) [p < 0.001] times higher and the risk of flame is 13.5 (5.0-36.1) [p < 0.001] times higher. Clinical Risk Estimates When modelling specific, clinically relevant scenarios, the risk (95%CI) of flame estimated when using 26W pulsed settings with 40% oxygen was 0.0003% (0 to 0.002) (Fig. 5 a) on uncharred muscle and 0.001% (0 to 0.05) on uncharred adipose tissue (Fig. 5 b). As a comparison, the most flammable combination (5W continuous setting on charred adipose tissue) demonstrated the likelihood of flame within 5 seconds is as high as 0.2% (0-1.6) with 40% oxygen and 5.7% (0-56.7) with 60% oxygen (Fig. 5 c). The inflection point for increased risk of flame with increasing oxygen varies depending on the specific combination of variables (laser mode, tissue type & charred status) (Fig. 5 ). Similar estimates were determined for the occurrence of spark (Supplementary figure S1). The least flammable combination (laser at 26W pulsed setting, on uncharred muscle) (Supplementary figure S1a) resulted in an estimated risk (95%CI) ranging from 0.01% (0-0.04) at 40% oxygen to 0.09% (0-0.5) at 60% oxygen. The most flammable combination (laser at 5W continuous setting, on charred adipose tissue) result in an estimated risk (95%CI) ranging from 1.8% (0-9.8) at 40% oxygen to 20.6% (0-100) at 60% oxygen. Discussion This is the first study to evaluate the risk of fire when using KTP laser in a high flow oxygen setting. Theoretically fire risks are reduced when THRIVE is used with the removal of potential fuel sources, the humidification of gases within the surgical field and the provision of an effective mechanism to remove laser smog. Furthermore, KTP laser has theoretical advantages over CO 2 laser in terms of reduced tissue heating dynamics 8 . However, this study demonstrates that these factors do not negate the possibility of an airway fire. Factors comprising of continuous laser mode, oxygen concentration greater than 60%, increased adiposity and the presence of char provide increased risk estimates of spark or flame, with many instances of flame occurring without a preceding spark. Native tissue that is high in adiposity or has been charred during the surgical process are highly combustible, and therefore a high level of vigilance is required of the surgeon to remove any charring when lasing with THRIVE. Oxygen concentration is an important predictor of the risk of spark and flame. An important clinical question is whether the oxygen concentration required to prevent airway fires is compatible with adequate patient oxygenation. The current recommendation from the Joint Commission on Accreditation of Healthcare Organizations is to use an oxygen concentration of less than 30% when delivered in an open manner during facial surgery 16 . Despite this recommendation, Roy & Smith were able to ignite a non-sustained flame when their laser struck and perforated the cuff of a laser safe endotracheal tube, using 5W CO 2 laser with an oxygen concentration of 29% for an unspecified length of time 2 . Importantly, the wider pulse width of the KTP laser allows slower heating, providing a theoretical smaller risk of combustion compared to CO 2 laser 8 . The current study demonstrates that clinically relevant combinations of oxygen concentration, laser setting and lasing duration result in reasonably low estimated risks; but these may still be considered too high in the clinical setting given the devastating consequences if airway fire is to occur. For example, an estimated risk of flame is 0.05% (5 fires per 10,000 lasing) with an upper limit of the 95% CI of 0.5% (5 fires per 1,000 lasing) at 50% oxygen with a 26W pulsed setting on uncharred adipose tissue. This risk is reduced when oxygen concentration is reduced to 40% (risk of 0.001% with an upper limit of 95% CI of 0.005%) or if the tissue type is uncharred muscle (estimated risk of 0.003% with upper limit of 95% CI of 0.03%). The oxygen concentration delivered during KTP laser use should be titrated according to patient’s oxygen requirements with the potential for delivering higher oxygen concentration when using pulsed KTP settings of lower power. We did not observe any sparks or flames when lasing for less than 5 seconds on uncharred tissue irrespective of oxygen concentration, laser power or tissue type. This indicates that KTP laser and the absence of a fuel source, such as an ETT, reduces the risk of combustion. Furthermore, lasing for less than 5 seconds at a time is highly unlikely to result in combustion. The consequences of an airway fire are severe; therefore, surgeons and anaesthetists should work together with the aim to minimise this risk as much as possible while balancing the risk of hypoxia. An oxygen-air blender can rapidly alter oxygen concentration, providing low oxygen fractions during periods of lasing. Further in-vivo studies are needed to determine the oxygen concentration at the level of the larynx when using an oxygen-air blender with THRIVE. Smoke evacuation using suction was identified as an important factor to reduce combustion of vaporised carbonised tissue (i.e. laser smog) when using CO 2 laser 3 . However, smoke evacuation was not demonstrated as an important factor in the current study. This may reflect the different tissue absorption characteristics of KTP laser with reduced surface temperature, resulting in less tissue vaporisation compared to the CO 2 laser 8 . Alternatively, the high flow rate of THRIVE at 70L/minute may also mean additional smoke evacuation via suction is redundant. In addition to removing laser smog, a high flow rate may also provide continuous positive pressure to reduce atelectasis and shunting of deoxygenated blood through the lungs when used in-vivo which may maintain oxygenation when using lower oxygen concentration. This is demonstrated in one previous study that an oxygen flow rate of 50L/min delivered via the nose is able to provide a positive airway pressure of 7cmH 2 O 1 7 . Spark is commonly used as a warning sign of flame; however, it is important to note that most flames occurred spontaneously without a preceding spark. When a spark did precede a flame, the time between spark and flame was highly variable, often less than 4 seconds. This suggests that sparks should not be used as a reliable indicator of imminent risk of sustained flame. The continuous laser settings of 2.6 W and 5W produced dangerously high clinical risk estimates of spark and flame. Despite 2.6W appearing to be of higher risk than 5W there was no statistical difference in the magnitude of these risk estimates with significant overlap of the 95% confidence interval. Regardless of the estimated clinical risk presented in this study, it would not be advisable to use either of these settings when using KTP laser in conjunction with THRIVE. The flames that occurred in this study were all successfully extinguished by turning the oxygen concentration down to 21% using the oxygen-air blender except for one episode where embers caught a piece of dry gauze underneath the apparatus. This was rapidly extinguished with water. This serves as a reminder that reducing the concentration of oxygen along with adequate safety preparation prior to commencing laser airway surgery are important safety steps in the event of an airway fire. It was also noted that when flame was ignited on charred tissue, it rapidly spread to other sections of the tissue. The spread of the flame can be prevented by removing charred tissue from within the surgical field. Limitations This model does not fully simulate a human respiratory system with gases entering the lungs and exiting along the same pathway (trachea), as most of the gas in this system will escape from the inferior end of the model. It also does not simulate the gas absorption that occurs in the human lungs. Therefore, ascertaining the concentration of oxygen at the level of the patient’s larynx during upper airway procedures using THRIVE is an important next step to translate this data into meaningful clinical recommendations. It would not be ethical nor practical to perform this study using live animals with the risk of airway fires and number of repeat experiments (> 2000 lasing) done to ensure reproducibility. Porcine tissue is frequently used as an analogue for human tissue in forensic sciences 18 and were used instead of human larynges. This study chose the most and least flammable tissue types, allowing us to present the range of risks associated with using KTP laser in this setting. The flammability characteristics of the surface mucous membrane during laryngeal surgery will be different to either adipose or muscle tissue, but will fall within the described range of risk prediction. Each porcine specimen may not have the exact same consistency of adiposity or muscle for each firing, but the chosen specimens were largely of the same tissue type macroscopically. KTP laser has an affinity for oxyhaemoglobin and as the tested tissue is non-living and has no circulating blood, this aspect could not be tested. Conclusion There remains a high risk of combustion when using KTP laser in a humidified oxygen rich environment especially with high oxygen concentration, charring and adiposity. Extreme caution should be taken to reduce or eliminate these factors when using KTP laser in a shared airway setting. When combining high flow oxygen with KTP laser for upper airway surgery with standard clinical equipment in a real operating room environment the following combinations provided low estimated risk of spark or flame: KTP laser in the pulsed mode with low wattages, minimising lasing time, reducing the oxygen concentration and avoiding lasing adipose or charred tissue. Sparks should not be relied on as reliable indicators of imminent flame. Declarations Acknowledgements We acknowledge and thank Olivia Lockwood and Roy Broughton at Flinders Medical Centre Biomedical Engineering Department for their expertise developing the stainless-steel model. Authors’ contribution LH designed the analysis, collected the data, interpreted the data and drafted the manuscript. AB designed the analysis, collected the data, analysed and interpreted the data and drafted the manuscript. MV collected the data and edited the manuscript. SU performed the statistical analysis, assisted with interpretation of the analyses and drafted the manuscript. CW conceived and designed the analysis, interpreted the data and drafted the manuscript. TA conceived and designed the analysis, collected the data, sourced equipment, interpreted the data and drafted the manuscript. EHO conceived and designed the analysis, collected the data, sourced equipment, interpreted the data and drafted the manuscript. All authors contributed to the writing of the manuscript and approved the final manuscript. Competing interests The authors declare that they have no competing interests. Data availability The datasets used and analysed during the current study are made available via the link provided. Ethics declarations Not applicable Consent to publish Not applicable References Day, A. T., Rivera, E., Farlow, J. L., Gourin, C. G. & Nussenbaum, B. Surgical Fires in Otolaryngology: A Systematic and Narrative Review. Otolaryngol Head Neck Surg , 158 , 598–616 https://doi.org/10.1177/0194599817746926 (2018). Roy, S. & Smith, L. P. Surgical fires in laser laryngeal surgery: are we safe enough? Otolaryngol Head Neck Surg , 152 , 67–72 https://doi.org/10.1177/0194599814555853 (2015). Stuermer, K. J., Ayachi, S., Gostian, A. O., Beutner, D. & Huttenbrink, K. B. Hazard of CO(2) laser-induced airway fire in laryngeal surgery: experimental data of contributing factors. Eur Arch Otorhinolaryngol , 270 , 2701–2707 https://doi.org/10.1007/s00405-013-2521-1 (2013). Yardley, I. E. & Donaldson, L. J. Surgical fires, a clear and present danger. The Surgeon , 8 , 87–92 https://doi.org/10.1016/j.surge.2010.01.005 (2010). Greenland, K. B., Stokan, M. J. & Culwick, M. D. Operating theatre fires: Adding more oxygen to the mix. Anaesth Intensive Care , 47 , 399–400 https://doi.org/10.1177/0310057x19860976 (2019). Onwochei, D., El-Boghdadly, K., Oakley, R. & Ahmad, I. Intra‐oral ignition of monopolar diathermy during transnasal humidified rapid‐insufflation ventilatory exchange (THRIVE. Anaesthesia , 72 , 781–783 https://doi.org/10.1111/anae.13873 (2017). Chang, M. Y. et al. Fire safety study on high-flow nasal oxygen in shared-airway surgeries with diathermy and laser: simulation based on a physical model. J. Clin. Monit. Comput , https://doi.org/10.1007/s10877-021-00690-4 (2021). Yan, Y. et al. Use of lasers in laryngeal surgery. J Voice , 24 , 102–109 https://doi.org/10.1016/j.jvoice.2008.09.006 (2010). Santos, P., Ayuso, A., Luis, M., Martinez, G. & Sala, X. Airway ignition during CO2 laser laryngeal surgery and high frequency jet ventilation. Eur J Anaesthesiol , 17 , 204–207 (2000). Sosis, M. B. Airway fire during co2 laser surgery using a Xomed Laser endotracheal tube., 72 , 747–749 https://doi.org/10.1097/00000542-199004000-00027 (1990). Yan, Y. et al. Use of Lasers in Laryngeal Surgery. Journal of Voice , 24 , 102–109 https://doi.org/10.1016/j.jvoice.2008.09.006 (2010). Broadhurst, M. S. et al. Effects of 532 nm pulsed-KTP laser parameters on vessel ablation in the avian chorioallantoic membrane: implications for vocal fold mucosa., 117 , 220–225 https://doi.org/10.1097/mlg.0b013e31802b5c1c (2007). Dhar, V. et al. Impact of oxygen concentration and laser power on occurrence of intraluminal fires during shared-airway surgery: an investigation. J. Laryngol. Otol , 122 , 1335–1338 https://doi.org/10.1017/S0022215108003101 (2008). Roy, S. & Smith, L. P. What does it take to start an oropharyngeal fire? Oxygen requirements to start fires in the operating room. Int J Pediatr Otorhinolaryngol , 75 , 227–230 (2011). Takanashi, S. et al. Airflow through the auxiliary line of the laser fiber prevents ignition of intra-airway fire during endoscopic laser surgery. Lasers Surg Med , 31 , 211–215 https://doi.org/10.1002/lsm.10097 (2002). Lampotang, S., Gravenstein, N., Paulus, D. A. & Gravenstein, D. Reducing the incidence of surgical fires: supplying nasal cannulae with sub-100% O2 gas mixtures from anesthesia machines. Anesth Analg , 101 , 1407–1412 https://doi.org/10.1213/01.Ane.0000180215.50589.02 (2005). Ritchie, J. E., Williams, A. B., Gerard, C. & Hockey, H. Evaluation of a humidified nasal high-flow oxygen system, using oxygraphy, capnography and measurement of upper airway pressures. Anaesth Intensive Care , 39 , 1103–1110 https://doi.org/10.1177/0310057x1103900620 (2011). Matuszewski, S. et al. Pigs vs people: the use of pigs as analogues for humans in forensic entomology and taphonomy research. Int J Legal Med , 134 , 793–810 https://doi.org/10.1007/s00414-019-02074-5 (2020). Additional Declarations No competing interests reported. Supplementary Files SupplementaryFigureS1.jpg Supplementary Figure S1 SupplementaryVideo1.mov Supplementary video 1 SupplementaryVideo2.mov Supplementary video 2 SupplementaryInfoFile.docx Supplementary File Cite Share Download PDF Status: Published Journal Publication published 11 Jan, 2022 Read the published version in Scientific Reports → Version 1 posted Editorial decision: Major revision 11 Nov, 2021 Reviews received at journal 03 Nov, 2021 Reviewers agreed at journal 18 Oct, 2021 Reviewers invited by journal 15 Oct, 2021 Editor assigned by journal 15 Oct, 2021 Editor invited by journal 23 Sep, 2021 Submission checks completed at journal 23 Sep, 2021 First submitted to journal 21 Sep, 2021 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-926775","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Research Article","associatedPublications":[],"authors":[{"id":53734203,"identity":"91332730-45b8-40be-8209-0e44a9a7e00e","order_by":0,"name":"Lucy Huang","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAA8klEQVRIiWNgGAWjYBACPhDB2ADjVgAxM3MDDsUQwIakBUidAWlBmECEFsY2VEuxa5FIfibBuOOwvDn/AvbHvPNqo/nbgVp+VGzDoyXNTILxzGHDnTMeMDbzbjueO+Mw0LaeM7fxaMlhk2BsO8y44cYBxubcbcdyG4BamBnbCGuxh2iZcyx3PrFaEjecbwBqaajJ3UBQC88zY4vEtvTkDTcYG2f/OXYgdyNQy0F8fuFnT35442Obte2G84cPfJxRU5c77/zhgw9+VODWAgQsEgkgSiKxAUgeBgsdwKceCJg/QOwDq6sjoHgUjIJRMApGIgAAKGZcqyPHiXYAAAAASUVORK5CYII=","orcid":"","institution":"Flinders University","correspondingAuthor":true,"prefix":"","firstName":"Lucy","middleName":"","lastName":"Huang","suffix":""},{"id":53734208,"identity":"0e9f0e83-3ecd-4fef-a983-ec1e6700c00e","order_by":1,"name":"Adam Badenoch","email":"","orcid":"","institution":"Flinders Medical Centre","correspondingAuthor":false,"prefix":"","firstName":"Adam","middleName":"","lastName":"Badenoch","suffix":""},{"id":53734210,"identity":"04d51214-bce7-4487-a425-938b5a9b22e4","order_by":2,"name":"Marthinus Vermeulen","email":"","orcid":"","institution":"Flinders Medical Centre","correspondingAuthor":false,"prefix":"","firstName":"Marthinus","middleName":"","lastName":"Vermeulen","suffix":""},{"id":53734212,"identity":"a3bf07e8-5f03-4b74-a4cc-e651dd8405ef","order_by":3,"name":"Shahid Ullah","email":"","orcid":"","institution":"Flinders University","correspondingAuthor":false,"prefix":"","firstName":"Shahid","middleName":"","lastName":"Ullah","suffix":""},{"id":53734214,"identity":"e88ccf13-61c3-42be-aedd-cff52ad1a346","order_by":4,"name":"Charmaine Woods","email":"","orcid":"","institution":"Flinders University","correspondingAuthor":false,"prefix":"","firstName":"Charmaine","middleName":"","lastName":"Woods","suffix":""},{"id":53734216,"identity":"893f87e1-3a73-4f6b-9da2-29254b1cbd07","order_by":5,"name":"Theodore Athanasiadis","email":"","orcid":"","institution":"Flinders Medical Centre","correspondingAuthor":false,"prefix":"","firstName":"Theodore","middleName":"","lastName":"Athanasiadis","suffix":""},{"id":53734217,"identity":"199b495f-68c7-4e19-ac4f-053c96aa8517","order_by":6,"name":"Eng Hooi Ooi","email":"","orcid":"","institution":"Flinders University","correspondingAuthor":false,"prefix":"","firstName":"Eng","middleName":"Hooi","lastName":"Ooi","suffix":""}],"badges":[],"createdAt":"2021-09-21 23:44:02","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-926775/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-926775/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1038/s41598-021-04636-3","type":"published","date":"2022-01-11T11:50:47+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":14081451,"identity":"8623d0c9-8ea6-47ad-be13-d27f2c72ee83","added_by":"auto","created_at":"2021-09-28 18:59:48","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":1959859,"visible":true,"origin":"","legend":"Experimental setup (a) Experimental setup with the stainless steel laryngeal model in an operating theatre environment with OptiflowTM; (b) The inlet of the laryngeal model with a plastic covering, OptiflowTM nasal cannula, oxygen sensor probe and USB camera; (c) The internal view of the model with a stainless-steel platform holding the porcine specimen.","description":"","filename":"Fig1.png","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/d24ffb4496e4d6147ceda89f.png"},{"id":14081454,"identity":"047e0066-71d8-4153-b868-12a08e2d4dcd","added_by":"auto","created_at":"2021-09-28 18:59:48","extension":"png","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":232906,"visible":true,"origin":"","legend":"An example of fresh and charred adipose tissue.","description":"","filename":"Figure2.png","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/f8cd1facf54c47dbd3fb1787.png"},{"id":14081822,"identity":"d7146e6d-5fc3-4265-9666-2cf0b2db8dea","added_by":"auto","created_at":"2021-09-28 19:02:48","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":3278311,"visible":true,"origin":"","legend":"Nelson-Aalen cumulative hazard function of spark and flame by (a) oxygen concentration (b) laser mode (c) tissue type (d) tissue condition (e) smoke evacuation based on ex-vivo experimental data","description":"","filename":"Figure3.png","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/90498485d768be06c9909004.png"},{"id":14081455,"identity":"20e81d63-146d-423b-9d31-62c0d37e4c89","added_by":"auto","created_at":"2021-09-28 18:59:48","extension":"png","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":819035,"visible":true,"origin":"","legend":"Coefficient plot from multivariate Cox proportional hazard models of (a) spark and (b) flame censored after 60 seconds from ex-vivo experimental data.","description":"","filename":"Figure4.png","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/80f329ab6c20bf6ce026a5b4.png"},{"id":14081452,"identity":"6bf39694-355e-4b13-95d9-503079e22ddf","added_by":"auto","created_at":"2021-09-28 18:59:48","extension":"png","order_by":5,"title":"Figure 5","display":"","copyAsset":false,"role":"figure","size":1170919,"visible":true,"origin":"","legend":"Estimated clinical risk of flame when lasing up to 5 seconds by oxygen concentration, laser mode, tissue type and charring based on experimental data. Percentages on the figures show the risks for oxygen concentration 40, 50, 60, and 90 respectively. (a) Laser setting: 26W pulsed, tissue: uncharred muscle; (b) Laser setting: 26W pulsed, tissue: uncharred adipose tissue; (c) Laser setting: 5W continuous, tissue: charred adipose tissue.","description":"","filename":"Figure5.png","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/7879fec0b11e612ff1b5e28e.png"},{"id":17200281,"identity":"76fd9a31-f84c-4d7c-86d1-3919edb84342","added_by":"auto","created_at":"2022-01-11 11:50:50","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":2765412,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/57670d92-1567-4833-852d-03926c99974a.pdf"},{"id":14081821,"identity":"24189e1c-13e3-4812-b890-329479926edc","added_by":"auto","created_at":"2021-09-28 19:02:48","extension":"jpg","order_by":1,"title":"","display":"","copyAsset":false,"role":"supplement","size":990129,"visible":true,"origin":"","legend":"Supplementary Figure S1","description":"","filename":"SupplementaryFigureS1.jpg","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/b3da54059867bddf367302b1.jpg"},{"id":14081461,"identity":"91b23b45-8315-4cf4-91d1-d2588dbf3349","added_by":"auto","created_at":"2021-09-28 18:59:49","extension":"mov","order_by":2,"title":"","display":"","copyAsset":false,"role":"supplement","size":41923714,"visible":true,"origin":"","legend":"Supplementary video 1","description":"","filename":"SupplementaryVideo1.mov","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/ae16a78fadddcfb8df21be0a.mov"},{"id":14081458,"identity":"4865a576-abe9-4015-9cd1-599df353de06","added_by":"auto","created_at":"2021-09-28 18:59:48","extension":"mov","order_by":3,"title":"","display":"","copyAsset":false,"role":"supplement","size":11999728,"visible":true,"origin":"","legend":"Supplementary video 2","description":"","filename":"SupplementaryVideo2.mov","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/e31c82076bb49faf8bc0d394.mov"},{"id":14081456,"identity":"6b3545c0-cc7d-4059-aa0c-295e7c89a591","added_by":"auto","created_at":"2021-09-28 18:59:48","extension":"docx","order_by":4,"title":"","display":"","copyAsset":false,"role":"supplement","size":13706,"visible":true,"origin":"","legend":"Supplementary File","description":"","filename":"SupplementaryInfoFile.docx","url":"https://assets-eu.researchsquare.com/files/rs-926775/v1/5703f78b9da871da809939d9.docx"}],"financialInterests":"No competing interests reported.","formattedTitle":"\u003cp\u003eRisk of Airway Fire with the use of KTP Laser and High Flow Humidified Oxygen Delivery in a Laryngeal Surgery Model\u003c/p\u003e","fulltext":[{"header":"Introduction","content":"\u003cp\u003eOperating-room airway fires are serious and potentially fatal complications but fortunately rare in otolaryngologic surgery\u003csup\u003e\u003cspan class=\"CitationRef\"\u003e1\u003c/span\u003e\u003c/sup\u003e. Airway fires have been described during adenotonsillectomy, tracheostomy and endoscopic airway surgery\u003csup\u003e\u003cspan class=\"CitationRef\"\u003e2\u003c/span\u003e\u003c/sup\u003e. The triad of essential elements required for an airway fire are oxygen, fuel, and an ignition source\u003csup\u003e\u003cspan class=\"CitationRef\"\u003e3\u003c/span\u003e\u003c/sup\u003e. Oxygen is in abundance in a shared airway setting where it may be delivered via a facemask, traditional nasal cannulae, supraglottic jet ventilation, endotracheal tube, or high-flow nasal oxygen. The ignition source is usually from the heat generated from electrocautery devices or lasers. Potential fuel sources include endotracheal tubes (ETT), gauze, drapes and the eschar from charred tissue\u003csup\u003e\u003cspan class=\"CitationRef\"\u003e4\u003c/span\u003e\u003c/sup\u003e.\u003c/p\u003e\n\u003cp\u003eTransnasal humidified rapid insufflation ventilatory exchange (THRIVE) is a method of oxygenating patients in a shared airway setting by delivering oxygen at a high flow rate to the lungs without an endotracheal tube. It allows for an unobstructed surgical field and eliminates the endotracheal tube as a potential fuel for ignition. Nasal high-flow oxygen used for THRIVE usually delivers 100% oxygen, however devices incorporating oxygen-air blenders are now available to alter the oxygen concentration delivered. Reports of fires during the use of nasal high flow oxygen in conjunction with electrocautery and laser are also emerging\u003csup\u003e\u003cspan class=\"CitationRef\"\u003e5\u003c/span\u003e\u0026ndash;\u003cspan class=\"CitationRef\"\u003e7\u003c/span\u003e\u003c/sup\u003e.\u003c/p\u003e\n\u003cp\u003eThe use of lasers in laryngeal surgery has increased over recent years, delivering targeted resection with improved haemostasis \u003csup\u003e\u003cspan class=\"CitationRef\"\u003e8\u003c/span\u003e\u003c/sup\u003e. The traditionally used carbon dioxide (CO\u003csub\u003e2\u003c/sub\u003e) laser has a wavelength of 10,600nm, which is strongly absorbed by water and tissue and is associated with most airway fire reports to date \u003csup\u003e\u003cspan class=\"CitationRef\"\u003e3\u003c/span\u003e,\u003cspan class=\"CitationRef\"\u003e9\u003c/span\u003e,\u003cspan class=\"CitationRef\"\u003e10\u003c/span\u003e\u003c/sup\u003e. By contrast, Potassium-titanyl-phosphate (KTP) laser is a solid-state laser with a wavelength of 532nm, resulting in specific absorption of energy by oxyhaemoglobin in red blood cells, producing photoangiolysis of blood vessels at lower tissue temperature with less vaporisation \u003csup\u003e\u003cspan class=\"CitationRef\"\u003e11\u003c/span\u003e,\u003cspan class=\"CitationRef\"\u003e12\u003c/span\u003e\u003c/sup\u003e. These factors may theoretically reduce the risk of an airway fire when used in upper airway surgery, compared with the CO\u003csub\u003e2\u003c/sub\u003e laser. Studies examining the factors that contribute to the risk of airway fires in clinical practice have largely been conducted using the CO\u003csub\u003e2\u003c/sub\u003e laser \u003csup\u003e3,13\u0026minus;15\u003c/sup\u003e. The study by Roy et al. used a mannequin intubated with a laser safe ETT, demonstrating an immediate sustained fire when the CO\u003csub\u003e2\u003c/sub\u003e laser struck and perforated the ETT cuff. This occurred with oxygen concentration as low as 40% indicating that traditional methods of airway management with an ETT for upper airway laser use are not risk free \u003csup\u003e\u003cspan class=\"CitationRef\"\u003e2\u003c/span\u003e\u003c/sup\u003e. Dhar et al studied CO\u003csub\u003e2\u003c/sub\u003e laser in combination with subglottic jet ventilation in a porcine model, identifying oxygen concentration, laser power and dry fuel source as independent risk factors for combustion \u003csup\u003e\u003cspan class=\"CitationRef\"\u003e13\u003c/span\u003e\u003c/sup\u003e. A subsequent study by Stuermer et al. confirmed laser power and oxygen concentration as risk factors and identified tissue type (adipose, cartilage, muscle), tissue quality (fresh, charred) and the use of smoke evacuation as additional independent risk factors for combustion in an ex-vivo plexiglass model using CO\u003csub\u003e2\u003c/sub\u003e laser\u003csup\u003e\u003cspan class=\"CitationRef\"\u003e3\u003c/span\u003e\u003c/sup\u003e. These two studies were conducted using non-humidified oxygen sources at flow rates significantly lower (jet ventilation at 2 bar and low flow rate at 10L/minute) than those generated when using THRIVE (70L/min) \u003csup\u003e\u003cspan class=\"CitationRef\"\u003e3\u003c/span\u003e,\u003cspan class=\"CitationRef\"\u003e13\u003c/span\u003e\u003c/sup\u003e. It is possible that 100% humidification of the gas mixture and the high flow rate provided by THRIVE reduces the risk of combustion\u003csup\u003e\u003cspan class=\"CitationRef\"\u003e15\u003c/span\u003e\u003c/sup\u003e.\u003c/p\u003e\n\u003cp\u003eThere has been no study investigating the risk of KTP laser causing an airway fire despite its common use in laryngeal surgery. The aim of this study is to examine the factors associated with combustion when using KTP laser in combination with humidified high-flow nasal oxygen. We developed an ex-vivo model which is designed to simulate laryngeal surgery to facilitate risk prediction of spark and flame under clinically relevant conditions.\u003c/p\u003e"},{"header":"Methods","content":"\u003cp\u003eHuman ethics was not required for this study as all experiments were performed using animal tissue (porcine muscle and adipose tissue) purchased from the local butcher. This study is listed on the Animal Register at Flinders University.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eThe ex-vivo experiment took place in the operating theatre using standard anaesthetic and operating equipment. A model was designed by the Biomedical Engineering Department to simulate the upper airway, consisting of a cylindrical stainless-steel chamber (outer diameter: 10cm, inner diameter: 5cm, length: 32cm; Figure 1a and b). Positioned superiorly, are openings for the Optiflow\u003csup\u003eTM\u003c/sup\u003e nasal canula, KTP laser fibre holder, suction, endoscopic camera, and an oxygen sensor to verify precise tissue oxygen concentration at the point of lasing. A plastic covering was used to reduce oxygen loss and maximise oxygen concentration within the chamber. Inferiorly, positioned 25cm from the opening is a metal platform that holds the tissue being lasered (Figure 1c). The Aura XP Laser Therapy System\u003csup\u003eTM\u003c/sup\u003e (Boston Scientific) was used with EndoStat 0.4mm laser fibres, using a non-contact firing technique. Optiflow\u003csup\u003eTM\u003c/sup\u003e (Fisher \u0026amp; Paykel), incorporating an oxygen-air blender, was used to provide flow rates of 70L/minute (min), simulating THRIVE with the ability to alter the oxygen concentration.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003ePorcine adipose and muscle tissue were used, as they represented \u0026nbsp;the most and least flammable tissue type in the study performed by Stuermer et al \u003csup\u003e3\u003c/sup\u003e. The KTP laser settings were chosen based on clinical relevance (2.6W continuous, 5W continuous, 26W pulsed and 35W pulsed settings; pulsed setting set at 15 millisecond pulse width, 2 pulse per second). Lasing was performed on both charred and uncharred, adipose and muscle tissue with variable oxygen concentrations (30%, 40%, 50%, 60%, 70%, 80%, 90%), with and without smoke evacuation. Each piece of tissue was placed in a plastic bag and warmed using a water bath to 30\u0026deg;C. Charring of tissue was conducted using a kitchen blow torch to enable even charring on tissue surface (Figure 2).\u003c/p\u003e\n\u003cp\u003e100% humidification and gas flow rate at 70L/min were used in every instance. Each combination of variables was repeated at least five times to ensure reproducibility. If a flame occurred, oxygen was immediately reduced to 21% using the oxygen-air blender while maintaining 70L/min flow rates, which rapidly extinguished the flame. Example videos have been provided in Supplementary video 1 and 2.\u003c/p\u003e\n\u003cp\u003e\u003cu\u003eOutcome measures\u003c/u\u003e\u003c/p\u003e\n\u003cp\u003eThe outcomes were the occurrence of a spark and/or flame. Flame is considered the most important patient-centred outcome; however, sparks are often used clinically as a surrogate marker to indicate increased risk of flame if lasing continues, therefore spark and flame were modelled separately from the same data set.\u0026nbsp;Time was measured from the start of lasing to the time to first spark/flame, or until 60 seconds.\u0026nbsp;A 60 second cut off time was used, as lasing beyond 60 seconds is not clinically relevant.\u003c/p\u003e\n\u003cp\u003e\u003cu\u003eStatistical methods\u0026nbsp;\u003c/u\u003e\u003c/p\u003e\n\u003cp\u003eA multivariate Cox proportional hazard model was used to examine the risk of spark/flame across tissue-oxygen concentration, laser setting, tissue type, charring and smoke evacuation. Time to event was measured from the time of lasing onset to the time of spark/flame, experiments were censored at 60 seconds. As each combination of experimental conditions was repeated 5 times the models captured the mixed effect using shared frailty \u0026ndash; the same random effect is shared by all repeated events within the same experimental group. The frailties are assumed to be gamma-distributed latent random effects that affect the hazard multiplicatively.\u0026nbsp;The variables included in the final multivariate model were\u0026nbsp;oxygen concentration, laser setting, tissue type and charring. The inclusion criterion was based on clinical importance, and statistical significance at P\u0026pound;0.20 from a univariate model. Variables tested experimentally and included in the univariate analyses were all previously identified as independent risk factors in previous studies using different laser types\u003csup\u003e3,15\u003c/sup\u003e. Smoke evacuation was subsequently excluded from the multivariable model based on non-significance in the univariate model. Additionally, re-inclusion of smoke evacuation into the final model did not result in a statistically significant association or significant change in the model coefficients. Proportional hazard assumption was tested by log-log plot of survival and Schoenfeld residuals and was found to be valid. Linear splines were employed to account for non-linearity of association between oxygen concentration and outcome hazard. The spline cut-off at 60% oxygen was selected based on it being an inflection point in the observed data and a judgement that this cut-off was clinically relevant in terms of the risk of hypoxia when THRIVE is used clinically. Cumulative hazard curves were evaluated by standard Nelson-Aalen cumulative hazard functions.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eThe clinically relevant probabilities of spark or flame\u0026nbsp;were established using the final multivariable Cox proportion hazard models by restricting the predictive model to 5 seconds of lasing (or time to event if \u0026lt;5 seconds) to facilitate a pragmatic and clinically relevant risk assessment. Probabilities were generated based on calculation of coefficients from the regression model and estimates of 5-second risk of spark or flame. In particular, the coefficient was multiplied by the value of the variable and then summed for each variable to get the scores.\u0026nbsp;The baseline survival function was then exponentiated by the score and then subtracted from 1 to calculate the 5-second risk. Finally, the adjusted predictions were displayed after using a restricted cubic spline to account for non-linear relationships between oxygen concentration and the risk of spark or flame.\u003c/p\u003e\n\u003cp\u003eModel diagnostics and goodness of fit were evaluated by Harrell\u0026apos;s C concordance statistic. The two-sided test was performed for all analysis and the level of significance was set at p \u0026lt;0.05.\u003c/p\u003e"},{"header":"Results","content":"\u003cp\u003eThe ex-vivo testing resulted in 2,182 firing episodes across a total of 224 combinations of variables. There were no missing data.\u003c/p\u003e \u003cp\u003eFlames were preceded by sparks in 6.4% of instances and occurred without sparks 93.6% of the time. In those instances where sparks preceded flames the median (25th -75th percentiles) time difference between spark and flame was 19 (4\u0026ndash;44) seconds.\u003c/p\u003e \u003cp\u003eNotably, no sparks or flames were observed when laser firing was limited to 5 seconds at fresh tissue irrespective of oxygen concentration, laser setting or tissue type.\u003c/p\u003e \u003cp\u003eOxygen concentration, laser mode, tissue type, and tissue quality were all independent risk factors for spark and flame (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e3\u003c/span\u003ea-d). Smoke evacuation was not a significant predictor of spark nor flame in either the univariate or multivariate analyses and was therefore excluded from the final multivariable model (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e3\u003c/span\u003ee). Results of the final multivariable model for spark and flame are presented in (Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e4\u003c/span\u003e). The Harrell's C concordance statistic for the multivariable model was 0.91 for spark and 0.94 for flame.\u003c/p\u003e \u003cp\u003eWhen compared with uncharred tissue, the risk (95% CI) of spark when lasing at charred tissue was increased by 34.9 (16.8\u0026ndash;72.5) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] and the risk of flame increased by 92.8 (31.8-270.4) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] (Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e4\u003c/span\u003e(b)).\u003c/p\u003e \u003cp\u003eFor oxygen concentration within the range 25\u0026ndash;59%, the risk (95% CI) of spark increased by 3.9 (2.4\u0026ndash;6.3) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] and flame increased by 6.6 (3.0-14.5) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] for every 10% increase in oxygen concentration. For oxygen concentration within the range 60\u0026ndash;90%, the risk of spark increased by 1.8 (1.3\u0026ndash;2.4) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] and flame increased by 2.3 (1.6\u0026ndash;3.4) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] for every 10% increase in oxygen concentration.\u003c/p\u003e \u003cp\u003eCompared with pulsed 26W (lowest power setting), pulsed 35W increased the risk (95% CI) of spark by 5.7 (2.0-15.7) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.01] and the risk of flame by 4.8 (1.2\u0026ndash;18.6) (p\u0026thinsp;\u0026lt;\u0026thinsp;0.05). The risk (95% CI) of spark at continuous 2.6W and 5W are increased by 28.8 (10.0-83.2) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001)] and 48.6 (17.0-138.8) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] respectively. The risk (95% CI) of flame at continuous 2.6W and 5W are increased by 72.8 (17.6-300.5) (p\u0026thinsp;\u0026lt;\u0026thinsp;0.001) and 47.1 (12.0-185.7) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] respectively. There was no statistically significant difference between the risk of spark or flame associated with 2.6W and 5W continuous settings when compared with each other.\u003c/p\u003e \u003cp\u003eCompared with muscle, the risk (95% CI) of spark when lasing at adipose tissue is 7.3 (3.6\u0026ndash;14.8) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] times higher and the risk of flame is 13.5 (5.0-36.1) [p\u0026thinsp;\u0026lt;\u0026thinsp;0.001] times higher.\u003c/p\u003e \u003cdiv id=\"Sec5\" class=\"Section2\"\u003e \u003ch2\u003eClinical Risk Estimates\u003c/h2\u003e \u003cp\u003eWhen modelling specific, clinically relevant scenarios, the risk (95%CI) of flame estimated when using 26W pulsed settings with 40% oxygen was 0.0003% (0 to 0.002) (Fig.\u0026nbsp;\u003cspan refid=\"Fig7\" class=\"InternalRef\"\u003e5\u003c/span\u003ea) on uncharred muscle and 0.001% (0 to 0.05) on uncharred adipose tissue (Fig.\u0026nbsp;\u003cspan refid=\"Fig7\" class=\"InternalRef\"\u003e5\u003c/span\u003eb). As a comparison, the most flammable combination (5W continuous setting on charred adipose tissue) demonstrated the likelihood of flame within 5 seconds is as high as 0.2% (0-1.6) with 40% oxygen and 5.7% (0-56.7) with 60% oxygen (Fig.\u0026nbsp;\u003cspan refid=\"Fig7\" class=\"InternalRef\"\u003e5\u003c/span\u003ec). The inflection point for increased risk of flame with increasing oxygen varies depending on the specific combination of variables (laser mode, tissue type \u0026amp; charred status) (Fig.\u0026nbsp;\u003cspan refid=\"Fig7\" class=\"InternalRef\"\u003e5\u003c/span\u003e).\u003c/p\u003e \u003cp\u003eSimilar estimates were determined for the occurrence of spark (Supplementary figure S1). The least flammable combination (laser at 26W pulsed setting, on uncharred muscle) (Supplementary figure S1a) resulted in an estimated risk (95%CI) ranging from 0.01% (0-0.04) at 40% oxygen to 0.09% (0-0.5) at 60% oxygen. The most flammable combination (laser at 5W continuous setting, on charred adipose tissue) result in an estimated risk (95%CI) ranging from 1.8% (0-9.8) at 40% oxygen to 20.6% (0-100) at 60% oxygen.\u003c/p\u003e \u003c/div\u003e"},{"header":"Discussion","content":"\u003cp\u003eThis is the first study to evaluate the risk of fire when using KTP laser in a high flow oxygen setting. Theoretically fire risks are reduced when THRIVE is used with the removal of potential fuel sources, the humidification of gases within the surgical field and the provision of an effective mechanism to remove laser smog. Furthermore, KTP laser has theoretical advantages over CO\u003csub\u003e2\u003c/sub\u003e laser in terms of reduced tissue heating dynamics\u003csup\u003e\u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e\u003c/sup\u003e. However, this study demonstrates that these factors do not negate the possibility of an airway fire. Factors comprising of continuous laser mode, oxygen concentration greater than 60%, increased adiposity and the presence of char provide increased risk estimates of spark or flame, with many instances of flame occurring without a preceding spark. Native tissue that is high in adiposity or has been charred during the surgical process are highly combustible, and therefore a high level of vigilance is required of the surgeon to remove any charring when lasing with THRIVE.\u003c/p\u003e \u003cp\u003eOxygen concentration is an important predictor of the risk of spark and flame. An important clinical question is whether the oxygen concentration required to prevent airway fires is compatible with adequate patient oxygenation. The current recommendation from the Joint Commission on Accreditation of Healthcare Organizations is to use an oxygen concentration of less than 30% when delivered in an open manner during facial surgery\u003csup\u003e\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e\u003c/sup\u003e. Despite this recommendation, Roy \u0026amp; Smith were able to ignite a non-sustained flame when their laser struck and perforated the cuff of a laser safe endotracheal tube, using 5W CO\u003csub\u003e2\u003c/sub\u003e laser with an oxygen concentration of 29% for an unspecified length of time \u003csup\u003e\u003cspan citationid=\"CR2\" class=\"CitationRef\"\u003e2\u003c/span\u003e\u003c/sup\u003e. Importantly, the wider pulse width of the KTP laser allows slower heating, providing a theoretical smaller risk of combustion compared to CO\u003csub\u003e2\u003c/sub\u003e laser\u003csup\u003e\u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e\u003c/sup\u003e. The current study demonstrates that clinically relevant combinations of oxygen concentration, laser setting and lasing duration result in reasonably low estimated risks; but these may still be considered too high in the clinical setting given the devastating consequences if airway fire is to occur. For example, an estimated risk of flame is 0.05% (5 fires per 10,000 lasing) with an upper limit of the 95% CI of 0.5% (5 fires per 1,000 lasing) at 50% oxygen with a 26W pulsed setting on uncharred adipose tissue. This risk is reduced when oxygen concentration is reduced to 40% (risk of 0.001% with an upper limit of 95% CI of 0.005%) or if the tissue type is uncharred muscle (estimated risk of 0.003% with upper limit of 95% CI of 0.03%). The oxygen concentration delivered during KTP laser use should be titrated according to patient\u0026rsquo;s oxygen requirements with the potential for delivering higher oxygen concentration when using pulsed KTP settings of lower power. We did not observe any sparks or flames when lasing for less than 5 seconds on uncharred tissue irrespective of oxygen concentration, laser power or tissue type. This indicates that KTP laser and the absence of a fuel source, such as an ETT, reduces the risk of combustion. Furthermore, lasing for less than 5 seconds at a time is highly unlikely to result in combustion. The consequences of an airway fire are severe; therefore, surgeons and anaesthetists should work together with the aim to minimise this risk as much as possible while balancing the risk of hypoxia. An oxygen-air blender can rapidly alter oxygen concentration, providing low oxygen fractions during periods of lasing. Further in-vivo studies are needed to determine the oxygen concentration at the level of the larynx when using an oxygen-air blender with THRIVE.\u003c/p\u003e \u003cp\u003eSmoke evacuation using suction was identified as an important factor to reduce combustion of vaporised carbonised tissue (i.e. laser smog) when using CO\u003csub\u003e2\u003c/sub\u003e laser\u003csup\u003e\u003cspan citationid=\"CR3\" class=\"CitationRef\"\u003e3\u003c/span\u003e\u003c/sup\u003e. However, smoke evacuation was not demonstrated as an important factor in the current study. This may reflect the different tissue absorption characteristics of KTP laser with reduced surface temperature, resulting in less tissue vaporisation compared to the CO\u003csub\u003e2\u003c/sub\u003e laser\u003csup\u003e\u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e\u003c/sup\u003e. Alternatively, the high flow rate of THRIVE at 70L/minute may also mean additional smoke evacuation via suction is redundant. In addition to removing laser smog, a high flow rate may also provide continuous positive pressure to reduce atelectasis and shunting of deoxygenated blood through the lungs when used in-vivo which may maintain oxygenation when using lower oxygen concentration. This is demonstrated in one previous study that an oxygen flow rate of 50L/min delivered via the nose is able to provide a positive airway pressure of 7cmH\u003csub\u003e2\u003c/sub\u003eO\u003csup\u003e1\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eSpark is commonly used as a warning sign of flame; however, it is important to note that most flames occurred spontaneously without a preceding spark. When a spark did precede a flame, the time between spark and flame was highly variable, often less than 4 seconds. This suggests that sparks should not be used as a reliable indicator of imminent risk of sustained flame.\u003c/p\u003e \u003cp\u003eThe continuous laser settings of 2.6 W and 5W produced dangerously high clinical risk estimates of spark and flame. Despite 2.6W appearing to be of higher risk than 5W there was no statistical difference in the magnitude of these risk estimates with significant overlap of the 95% confidence interval. Regardless of the estimated clinical risk presented in this study, it would not be advisable to use either of these settings when using KTP laser in conjunction with THRIVE.\u003c/p\u003e \u003cp\u003eThe flames that occurred in this study were all successfully extinguished by turning the oxygen concentration down to 21% using the oxygen-air blender except for one episode where embers caught a piece of dry gauze underneath the apparatus. This was rapidly extinguished with water. This serves as a reminder that reducing the concentration of oxygen along with adequate safety preparation prior to commencing laser airway surgery are important safety steps in the event of an airway fire. It was also noted that when flame was ignited on charred tissue, it rapidly spread to other sections of the tissue. The spread of the flame can be prevented by removing charred tissue from within the surgical field.\u003c/p\u003e \u003cdiv id=\"Sec7\" class=\"Section2\"\u003e \u003ch2\u003eLimitations\u003c/h2\u003e \u003cp\u003eThis model does not fully simulate a human respiratory system with gases entering the lungs and exiting along the same pathway (trachea), as most of the gas in this system will escape from the inferior end of the model. It also does not simulate the gas absorption that occurs in the human lungs. Therefore, ascertaining the concentration of oxygen at the level of the patient\u0026rsquo;s larynx during upper airway procedures using THRIVE is an important next step to translate this data into meaningful clinical recommendations.\u003c/p\u003e \u003cp\u003eIt would not be ethical nor practical to perform this study using live animals with the risk of airway fires and number of repeat experiments (\u0026gt;\u0026thinsp;2000 lasing) done to ensure reproducibility. Porcine tissue is frequently used as an analogue for human tissue in forensic sciences \u003csup\u003e\u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e\u003c/sup\u003e and were used instead of human larynges. This study chose the most and least flammable tissue types, allowing us to present the range of risks associated with using KTP laser in this setting. The flammability characteristics of the surface mucous membrane during laryngeal surgery will be different to either adipose or muscle tissue, but will fall within the described range of risk prediction. Each porcine specimen may not have the exact same consistency of adiposity or muscle for each firing, but the chosen specimens were largely of the same tissue type macroscopically. KTP laser has an affinity for oxyhaemoglobin and as the tested tissue is non-living and has no circulating blood, this aspect could not be tested.\u003c/p\u003e \u003c/div\u003e"},{"header":"Conclusion","content":"\u003cp\u003eThere remains a high risk of combustion when using KTP laser in a humidified oxygen rich environment especially with high oxygen concentration, charring and adiposity. Extreme caution should be taken to reduce or eliminate these factors when using KTP laser in a shared airway setting. When combining high flow oxygen with KTP laser for upper airway surgery with standard clinical equipment in a real operating room environment the following combinations provided low estimated risk of spark or flame: KTP laser in the pulsed mode with low wattages, minimising lasing time, reducing the oxygen concentration and avoiding lasing adipose or charred tissue. Sparks should not be relied on as reliable indicators of imminent flame.\u003c/p\u003e"},{"header":"Declarations","content":"\u003ch2\u003eAcknowledgements\u0026nbsp;\u003c/h2\u003e\n\u003cp\u003eWe acknowledge and thank Olivia Lockwood and Roy Broughton at Flinders Medical Centre Biomedical Engineering Department for their expertise developing the stainless-steel model.\u0026nbsp;\u0026nbsp;\u003c/p\u003e\n\u003ch2\u003eAuthors\u0026rsquo;\u0026nbsp;contribution\u0026nbsp;\u003c/h2\u003e\n\u003cp\u003eLH designed the analysis, collected the data, interpreted the data and drafted the manuscript. AB designed the analysis, collected the data, analysed and interpreted the data and drafted the manuscript. MV collected the data and edited the manuscript. SU performed the statistical analysis, assisted with interpretation of the analyses and drafted the manuscript. CW conceived and designed the analysis, interpreted the data and drafted the manuscript. TA conceived and designed the analysis, collected the data, sourced equipment, interpreted the data and drafted the manuscript. EHO conceived and designed the analysis, collected the data, sourced equipment, interpreted the data and drafted the manuscript. All authors contributed to the writing of the manuscript and approved the final manuscript.\u003c/p\u003e\n\u003ch2\u003eCompeting\u0026nbsp;interests\u0026nbsp;\u003c/h2\u003e\n\u003cp\u003eThe authors declare that they have no competing interests.\u0026nbsp;\u003c/p\u003e\n\u003ch2\u003eData availability\u003c/h2\u003e\n\u003cp\u003eThe datasets used and analysed during the current study are made available via the link provided.\u0026nbsp;\u003c/p\u003e\n\u003ch2\u003eEthics declarations\u0026nbsp;\u003c/h2\u003e\n\u003cp\u003eNot applicable\u0026nbsp;\u003c/p\u003e\n\u003ch2\u003eConsent to publish\u003c/h2\u003e\n\u003cp\u003eNot applicable\u0026nbsp;\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\u003cli\u003e\u003cspan\u003eDay, A. T., Rivera, E., Farlow, J. L., Gourin, C. G. \u0026amp; Nussenbaum, B. Surgical Fires in Otolaryngology: A Systematic and Narrative Review. \u003cem\u003eOtolaryngol Head Neck Surg\u003c/em\u003e, \u003cb\u003e158\u003c/b\u003e, 598\u0026ndash;616 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1177/0194599817746926\u003c/span\u003e\u003c/span\u003e (2018).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRoy, S. \u0026amp; Smith, L. P. Surgical fires in laser laryngeal surgery: are we safe enough? \u003cem\u003eOtolaryngol Head Neck Surg\u003c/em\u003e, \u003cb\u003e152\u003c/b\u003e, 67\u0026ndash;72 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1177/0194599814555853\u003c/span\u003e\u003c/span\u003e (2015).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eStuermer, K. J., Ayachi, S., Gostian, A. O., Beutner, D. \u0026amp; Huttenbrink, K. B. Hazard of CO(2) laser-induced airway fire in laryngeal surgery: experimental data of contributing factors. \u003cem\u003eEur Arch Otorhinolaryngol\u003c/em\u003e, \u003cb\u003e270\u003c/b\u003e, 2701\u0026ndash;2707 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00405-013-2521-1\u003c/span\u003e\u003c/span\u003e (2013).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYardley, I. E. \u0026amp; Donaldson, L. J. Surgical fires, a clear and present danger. \u003cem\u003eThe Surgeon\u003c/em\u003e, \u003cb\u003e8\u003c/b\u003e, 87\u0026ndash;92 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.surge.2010.01.005\u003c/span\u003e\u003c/span\u003e (2010).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGreenland, K. B., Stokan, M. J. \u0026amp; Culwick, M. D. Operating theatre fires: Adding more oxygen to the mix. \u003cem\u003eAnaesth Intensive Care\u003c/em\u003e, \u003cb\u003e47\u003c/b\u003e, 399\u0026ndash;400 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1177/0310057x19860976\u003c/span\u003e\u003c/span\u003e (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eOnwochei, D., El-Boghdadly, K., Oakley, R. \u0026amp; Ahmad, I. Intra‐oral ignition of monopolar diathermy during transnasal humidified rapid‐insufflation ventilatory exchange (THRIVE. \u003cem\u003eAnaesthesia\u003c/em\u003e, \u003cb\u003e72\u003c/b\u003e, 781\u0026ndash;783 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1111/anae.13873\u003c/span\u003e\u003c/span\u003e (2017).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eChang, M. Y. \u003cem\u003eet al.\u003c/em\u003e Fire safety study on high-flow nasal oxygen in shared-airway surgeries with diathermy and laser: simulation based on a physical model. \u003cem\u003eJ. Clin. Monit. Comput\u003c/em\u003e, \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s10877-021-00690-4\u003c/span\u003e\u003c/span\u003e (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYan, Y. \u003cem\u003eet al.\u003c/em\u003e Use of lasers in laryngeal surgery. \u003cem\u003eJ Voice\u003c/em\u003e, \u003cb\u003e24\u003c/b\u003e, 102\u0026ndash;109 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.jvoice.2008.09.006\u003c/span\u003e\u003c/span\u003e (2010).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSantos, P., Ayuso, A., Luis, M., Martinez, G. \u0026amp; Sala, X. Airway ignition during CO2 laser laryngeal surgery and high frequency jet ventilation. \u003cem\u003eEur J Anaesthesiol\u003c/em\u003e, \u003cb\u003e17\u003c/b\u003e, 204\u0026ndash;207 (2000).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSosis, M. B. Airway fire during co2 laser surgery using a Xomed Laser endotracheal tube., \u003cb\u003e72\u003c/b\u003e, 747\u0026ndash;749 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1097/00000542-199004000-00027\u003c/span\u003e\u003c/span\u003e (1990).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYan, Y. \u003cem\u003eet al.\u003c/em\u003e Use of Lasers in Laryngeal Surgery. \u003cem\u003eJournal of Voice\u003c/em\u003e, \u003cb\u003e24\u003c/b\u003e, 102\u0026ndash;109 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1016/j.jvoice.2008.09.006\u003c/span\u003e\u003c/span\u003e (2010).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBroadhurst, M. S. \u003cem\u003eet al.\u003c/em\u003e Effects of 532 nm pulsed-KTP laser parameters on vessel ablation in the avian chorioallantoic membrane: implications for vocal fold mucosa., \u003cb\u003e117\u003c/b\u003e, 220\u0026ndash;225 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1097/mlg.0b013e31802b5c1c\u003c/span\u003e\u003c/span\u003e (2007).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDhar, V. \u003cem\u003eet al.\u003c/em\u003e Impact of oxygen concentration and laser power on occurrence of intraluminal fires during shared-airway surgery: an investigation. \u003cem\u003eJ. Laryngol. Otol\u003c/em\u003e, \u003cb\u003e122\u003c/b\u003e, 1335\u0026ndash;1338 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1017/S0022215108003101\u003c/span\u003e\u003c/span\u003e (2008).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRoy, S. \u0026amp; Smith, L. P. What does it take to start an oropharyngeal fire? Oxygen requirements to start fires in the operating room. \u003cem\u003eInt J Pediatr Otorhinolaryngol\u003c/em\u003e, \u003cb\u003e75\u003c/b\u003e, 227\u0026ndash;230 (2011).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eTakanashi, S. \u003cem\u003eet al.\u003c/em\u003e Airflow through the auxiliary line of the laser fiber prevents ignition of intra-airway fire during endoscopic laser surgery. \u003cem\u003eLasers Surg Med\u003c/em\u003e, \u003cb\u003e31\u003c/b\u003e, 211\u0026ndash;215 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1002/lsm.10097\u003c/span\u003e\u003c/span\u003e (2002).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLampotang, S., Gravenstein, N., Paulus, D. A. \u0026amp; Gravenstein, D. Reducing the incidence of surgical fires: supplying nasal cannulae with sub-100% O2 gas mixtures from anesthesia machines. \u003cem\u003eAnesth Analg\u003c/em\u003e, \u003cb\u003e101\u003c/b\u003e, 1407\u0026ndash;1412 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1213/01.Ane.0000180215.50589.02\u003c/span\u003e\u003c/span\u003e (2005).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRitchie, J. E., Williams, A. B., Gerard, C. \u0026amp; Hockey, H. Evaluation of a humidified nasal high-flow oxygen system, using oxygraphy, capnography and measurement of upper airway pressures. \u003cem\u003eAnaesth Intensive Care\u003c/em\u003e, \u003cb\u003e39\u003c/b\u003e, 1103\u0026ndash;1110 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1177/0310057x1103900620\u003c/span\u003e\u003c/span\u003e (2011).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMatuszewski, S. \u003cem\u003eet al.\u003c/em\u003e Pigs vs people: the use of pigs as analogues for humans in forensic entomology and taphonomy research. \u003cem\u003eInt J Legal Med\u003c/em\u003e, \u003cb\u003e134\u003c/b\u003e, 793\u0026ndash;810 \u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003ehttps://doi.org/10.1007/s00414-019-02074-5\u003c/span\u003e\u003c/span\u003e (2020).\u003c/span\u003e\u003c/li\u003e\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"
[email protected]","identity":"scientific-reports","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"scirep","sideBox":"Learn more about [Scientific Reports](http://www.nature.com/srep/)","snPcode":"","submissionUrl":"","title":"Scientific Reports","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Scientific Reports","inReviewEnabled":true,"inReviewRevisionsEnabled":true},"keywords":"THRIVE, KTP laser, airway fire, high flow oxygen","lastPublishedDoi":"10.21203/rs.3.rs-926775/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-926775/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003eBackground \u003c/p\u003e\u003cp\u003eAirway surgery presents a unique environment for operating room fire to occur. This study aims to explore the factors of combustion when using KTP laser with high flow oxygen in an ex-vivo model. \u003c/p\u003e\u003cp\u003eMethods\u003c/p\u003e\u003cp\u003eThe variables tested were varying tissue type, tissue condition, oxygen concentration, laser setting, and smoke evacuation in a stainless-steel model. Outcome measures were time of lasing to the first spark and/or flame. A multivariate Cox proportional hazard model was used to determine the risk of spark and flame across the different risk factors. \u003c/p\u003e\u003cp\u003eResults\u003c/p\u003e\u003cp\u003eFor every 10% increase in oxygen concentration above 60% the risk of flame increased by a factor of 2.3. Continuous laser setting at 2.6W increased the risk by a factor of 72.8. The risk of lasing adipose tissue is 7.3 times higher than that of muscle. Charred tissue increases the risk of flame by a factor of 92.8. \u0026nbsp;Flame occurred without a preceding spark 93.6% of the time. \u003c/p\u003e\u003cp\u003eConclusions \u003c/p\u003e\u003cp\u003eUsing KTP laser in the pulsed mode with low wattages, minimising lasing time, reducing the oxygen concentration and avoiding lasing adipose or charred tissue produce a relatively low estimated risk of spark or flame.\u003c/p\u003e","manuscriptTitle":"Risk of Airway Fire with the use of KTP Laser and High Flow Humidified Oxygen Delivery in a Laryngeal Surgery Model","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2021-09-28 18:59:46","doi":"10.21203/rs.3.rs-926775/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"decision","content":"Major revision","date":"2021-11-11T06:02:05+00:00","index":"","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2021-11-03T14:49:18+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"dc6925e3-3191-4d92-bcbd-6396143280f4","date":"2021-10-19T03:32:59+00:00","index":"hide","fulltext":""},{"type":"reviewersInvited","content":"","date":"2021-10-15T08:34:56+00:00","index":"","fulltext":""},{"type":"editorAssigned","content":"","date":"2021-10-15T08:31:00+00:00","index":"","fulltext":""},{"type":"editorInvited","content":"","date":"2021-09-23T12:51:59+00:00","index":"","fulltext":""},{"type":"checksComplete","content":"","date":"2021-09-23T12:40:06+00:00","index":"","fulltext":""},{"type":"submitted","content":"Scientific Reports","date":"2021-09-21T23:32:11+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"
[email protected]","identity":"scientific-reports","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"scirep","sideBox":"Learn more about [Scientific Reports](http://www.nature.com/srep/)","snPcode":"","submissionUrl":"","title":"Scientific Reports","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Scientific Reports","inReviewEnabled":true,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"2c95411e-b94e-4868-8036-7682b4f823d7","owner":[],"postedDate":"September 28th, 2021","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[{"id":7506833,"name":"Other Public Policy"},{"id":7506834,"name":"Health Policy"},{"id":7506835,"name":"Anesthesiology \u0026 Pain Medicine"}],"tags":[],"updatedAt":"2022-01-11T11:50:47+00:00","versionOfRecord":{"articleIdentity":"rs-926775","link":"https://doi.org/10.1038/s41598-021-04636-3","journal":{"identity":"scientific-reports","isVorOnly":false,"title":"Scientific Reports"},"publishedOn":"2022-01-11 11:50:47","publishedOnDateReadable":"January 11th, 2022"},"versionCreatedAt":"2021-09-28 18:59:46","video":"","vorDoi":"10.1038/s41598-021-04636-3","vorDoiUrl":"https://doi.org/10.1038/s41598-021-04636-3","workflowStages":[]},"version":"v1","identity":"rs-926775","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-926775","identity":"rs-926775","version":["v1"]},"buildId":"_2-kVJe1T_tPrBINL-cwx","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.