Physicians recognized and could differentiate dural puncture click sensations among needle types, which correlated well with objective force measurements of needle penetration.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

Background We hypothesized that the click perceived when puncturing the dura-arachnoid with fine-gauge spinal needles can be subjectively identified, and investigated whether it may be distinguishable among different needle types. Methods Subjective and objective evaluations were performed. First, physicians punctured the polyamide film or porcine dura mater (n=70 and n=20, respectively) with seven types of spinal needles and numerically evaluated the perceived click sensations. Using an 11-point numerical rating scale (from “0” for “no click sensation” to “10” for “the strongest click perceived”) data, subjective differentiation among needle types was assessed. Second, in the objective part of the study, total forces elicited by polyamide film or porcine dura mater punctures with each needle were measured using a biomechanical testing device, and load-displacement curves evaluated. Third, the results of subjective and objective evaluations were compared. Results All participants recognized the click and could discriminate among needles of different tip shape. The load-displacement curves for polyamide film and porcine dura mater were similar and needle-specific. The subjective numerical rating scale values corresponded well with the objectively measured changes in total forces ( R 2 = 0.862 and R 2 = 0.881 for polyamide film and porcine dura mater, respectively), indicating that an increase in the largest drop in total force value of 0.30 N or 0.21 N would produce an increase of numerical rating scale value of 1 for polyamide film and porcine dura mater, respectively. Conclusions We provide an objective proof of the click sensation felt upon dural puncture using different fine-gauge spinal needles. Click recognition could be used as an additional indicator of successful spinal puncture.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00