Image-guided laparoscopic surgery in an open MRI operating theater

Surgical endoscopy · 2013 · vol. 27(6) , pp. 2178–84 · doi:10.1007/s00464-012-2737-y · PMID:23355150
Case report OA: closed
View on PubMed View at publisher
⚙ AI-generated summary by qwen3.7-flash, 2026-08-23 ⓘ

Five patients underwent laparoscopic surgery in a 0.4-T open MRI operating theater, demonstrating that real-time augmented reality navigation with intraperitoneal structures is feasible using magnetic resonance-incompatible instruments outside the 5-Gs restriction area.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

BACKGROUND: The recent development of open magnetic resonance imaging (MRI) has provided an opportunity for the next stage of image-guided surgical and interventional procedures. The purpose of this study was to evaluate the feasibility of laparoscopic surgery under the pneumoperitoneum with the system of an open MRI operating theater. METHODS: Five patients underwent laparoscopic surgery with a real-time augmented reality navigation system that we previously developed in a horizontal-type 0.4-T open MRI operating theater. RESULTS: All procedures were performed in an open MRI operating theater. During the operations, the laparoscopic monitor clearly showed the augmented reality models of the intraperitoneal structures, such as the common bile ducts and the urinary bladder, as well as the proper positions of the prosthesis. The navigation frame rate was 8 frames per min. The mean fiducial registration error was 6.88 ± 6.18 mm in navigated cases. We were able to use magnetic resonance-incompatible surgical instruments out of the 5-Gs restriction area, as well as conventional laparoscopic surgery, and we developed a real-time augmented reality navigation system using open MRI. CONCLUSIONS: Laparoscopic surgery with our real-time augmented reality navigation system in the open MRI operating theater is a feasible option.

My notes (saved in your browser only)

MeSH descriptors

Laparoscopy Magnetic Resonance Imaging, Interventional Surgery, Computer-Assisted Adenomyosis Adenomyosis Aged Cholecystectomy, Laparoscopic Cholecystectomy, Laparoscopic Cholecystolithiasis Cholecystolithiasis Feasibility Studies Female Hernia, Ventral Hernia, Ventral Herniorrhaphy Herniorrhaphy Humans Laparoscopy Magnetic Resonance Imaging, Interventional Male

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-10-11T09:27:45.537177+00:00
pubmed
last seen: 2026-10-08T21:11:19.299510+00:00
unpaywall