How Many Tiers Do We Need? Type I Errors and Power in Multiple Baseline Designs

preprint OA: closed
View at publisher

Abstract

Design quality guidelines typically recommend that multiple baseline designs include at least three demonstrations of effects. Despite its widespread adoption, this recommendation does not appear grounded in empirical evidence. The main purpose of our study was to address this issue by assessing Type I error rate and power in multiple baseline designs. First, we generated 10,000 multiple baseline graphs, applied the dual-criteria method to each tier, and computed Type I error rate and power for different number of tiers showing a clear change. Second, two raters categorized the tiers for 300 multiple baseline graphs to replicate our analyses using visual inspection. When multiple baseline designs had at least three tiers and two or more of these tiers showed a clear change, the Type I error rate remained adequate ( .80). In contrast, requiring all tiers to show a clear change resulted in overly stringent conclusions (i.e., unacceptably low power). Therefore, researchers and practitioners should carefully consider limitations in power when requiring all tiers of a multiple baseline design to show a clear change in their analyses.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00