A 3.55-μm ultrathin, skin-like mechanoresponsive, compliant, and seamless ionic conductive electrode for epidermal electrophysiological signal acquisition and human-machine-interaction | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Research Article A 3.55-μm ultrathin, skin-like mechanoresponsive, compliant, and seamless ionic conductive electrode for epidermal electrophysiological signal acquisition and human-machine-interaction Likun Zhang, Zhenglin Chen, Huazhang Ying, Zhicheng Du, Ziwu Song, and 11 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-3892812/v1 This work is licensed under a CC BY 4.0 License Status: Posted Version 1 posted You are reading this latest preprint version Abstract Flexible ionic conductive electrodes, as a fundamental component for electrical signal transmission, play a crucial role in skin-surface electronic devices. Developing a skin-seamlessly electrode that can effectively capture long-term, artifacts-free, and high-quality electrophysiological signals, remains a challenge. Herein, we report an ultra-thin and dry electrode consisting of deep eutectic solvent (DES) and zwitterions (CEAB), which exhibit significantly lower reactance and noise in both static and dynamic monitoring compared to standard Ag/AgCl gel electrodes. Our electrodes have skin-like mechanical properties (strain-rigidity relationship and flexibility), outstanding adhesion, and high electrical conductivity. Consequently, they excel in consistently capturing high-quality epidermal biopotential signals, such as the electrocardiogram (ECG), electromyogram (EMG), and electroencephalogram (EEG) signals. Furthermore, we demonstrate the promising potential of the electrodes in clinical applications by effectively distinguishing aberrant EEG signals associated with depressive patients. Meanwhile, through the integration of CEAB electrodes with digital processing and advanced algorithms, valid gesture control of artificial limbs based on EMG signals is achieved, highlighting its capacity to significantly enhance human-machine interaction. Electronic Materials and Devices ultrathin skin-like mechanoresponsive compliant seamless ionic conductive electrode Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Introduction Flexible ionic conductive electrodes play a pivotal role in skin-surface electronic devices by facilitating electrical signal transmission 1 – 4 . They are indispensable for tasks such as continuous, non-invasive health monitoring 5 – 7 and swift, efficient human-computer interactions 8 – 10 . For effective long-term acquisition of electrophysiological signals from the skin surface, electrode materials must possess specific attributes: adhesion 11 – 13 , stretchability 13 , 14 , Young's modulus similar to skin 14 , 15 , excellent conductivity 16 , 17 , and self-healing 18 – 21 after external damage. Two types of skin electrodes: metal dry electrodes 22 – 27 and hydrogel wet electrodes 28 , 29 , are available on the market. While metal dry electrodes have stable physical and chemical characteristics, their limited stretchability and adhesive capabilities can cause signal distortions due to human movement 30 – 32 . In contrast, hydrogel electrodes excel in biocompatibility 33 , 34 , conductivity, and skin conformity 35 . Yet, they lose water over time 36 , diminishing their conductivity, stretchability, and softness; especially freezing at low temperatures and dehydration at high temperatures can compromise signal acquisition 37 , 38 . Deep eutectic solvents (DESs) are promising, safe, and stable alternatives to conventional soft ionic conductors 39 , 40 . Comprising hydrogen bond donors (e.g., ethylene glycol, EG) and acceptors (e.g., choline chloride, ChCl) 40 , 41 , these solvents are water-free, have low vapor pressure, and exhibit strong conductivity and biocompatibility 42 , 43 . The composite advantages of DESs have spurred rapid development in ionic conductors 44 , 45 . Li et al combined acrylic acid (AA) with DESs to prepare the DES gel with stretchability (> 1000%), high conductivity (1.26 mSžcm − 1 ), and high adhesion to the skin (~ 100 Nžm − 1 ) 46 . Despite these advancements, creating a DES gel with both self-healing and skin-like mechanical properties remains a challenge. Human skin is self-repairable, restoring both its mechanical and electrical functionalities 47 . Distinctively, human skin exhibits a nonlinear stress-strain relationship, resembling the shape of J 48 – 50 . While it feels soft upon touch, and swiftly stiffens under high strains to prevent damage. Inspired by skin’s mechanic properties, a hybrid network that blends weakly complex zwitterions with robust hydrogen bond interactions can emulate skin's softness while rapidly stiffening under strain, mimicking its protective mechanism. In this study, we develop an ionic, conductive, compliant, dry, adhesive, and self-healing electrode for epidermal electrophysiology monitoring, depression detection, and human-machine interaction. We use ChCl and EG as the deep eutectic solvent (DES), betaine as the zwitterionic network and crosslinker, and AA to form the conductive framework. This novel CEAB electrode surpasses traditional Ag/AgCl gel electrodes in epidermal biopotential monitoring. It ensures improved conductivity across a wide temperature range, offers gentle conformability to the skin, and significantly reduces noise levels during dynamic detections. we can use the CEAB electrodes to capture high-quality epidermal biopotential signals consistently, such as electrocardiogram (ECG), electromyogram (EMG), and electroencephalogram (EEG) 51 , even amidst movement. Furthermore, we develop a machine-learning algorithm that effectively identifies abnormal EEG patterns in patients with depression. Meanwhile, by integrating this electrode with shallow CNN (Convolution Neural Network) algorithm, we demonstrate prosthetic limb control as gesture replication based on EMG signals. A comparison of CEAB electrodes to representative electrodes for biopotential applications is shown in Supplementary Table 1. Results Fabrication and characterization of CEAB We first develop a method to prepare CEAB film with controlled thickness and scalability, based on the pressure exertion. The fabrication process of the electrode is illustrated in Fig. 1 b (Further setup details in Supplementary Fig. S1a). Firstly, the DES is synthesized by mixing ChCl and EG stirred at 80 ℃ for 20 mins. Then monomer AA is dissolved in DES to form a clear solution 46 . After that, the betaine as zwitterion, and Irgacure 2959 as the photoinitiator are dissolved in the solution to prepare the CEAB precursor. The precursor solution consists of ChCl, EG, AA, and betaine in a molar ratio of 2:4:4:1, and the weight percentage of Irgacure 2959 is 0.1% (Fig. 1 a). The transparent precursor (Supplementary Fig. S1b) is then cast between two pieces of Polyethylene terephthalate (PET) supporting films, covered by a flat glass mold, different forces are exerted on the surface to generate precursor layer with different thickness. Upon polymerization of the precursor using UV light (365 nm, 10 W power, 5 min), the resulting CEAB gel serves as an adhesive and stretchable dry electrode for capturing epidermal biopotentials such as ECG, EMG, and EEG (Fig. 1 d). The thickness of the CEAB film is influenced primarily by two main factors: the magnitude and duration of pressure. Ensuring proper duration of pressure facilitates precursor diffusion between the PET films, subsequently impacting the film's thickness post-photopolymerization. Precursor diffusion largely completes within 5 minutes under free load, as evidenced in Supplementary Movie 1. Therefore, we set the pressure duration to 5 minutes. Figure 2 a demonstrates that the CEAB film's thickness can be varied via the applied forces on the glass surface. Specifically, when controlling the pressure from 4109 to 0 Pa, the thickness is changed from 3.55 µm to approximately 46.9 µm. For films with a thickness surpassing 50 µm, we employ a molding strategy. This involves placing a spacer with a specific thickness between two glass plates and PET support films, followed by film removal post-curing. We coat the PET film's surface with silicone oil to ease the CEAB film's separation, a critical step for maintaining the structural integrity of sub-5µm freestanding samples 52 . Scanning electron microscope (SEM) and atomic force microscope (AFM) (Fig. 2 b and 2 c) both show the freestanding CEAB film's smooth morphology, indicating considerable macro-scale homogeneity. Moreover, the AFM height image reveals that the CEAB film's surface roughness remains below 10 nm (Fig. 2 c and Supplementary Fig.S2). In comparison to traditional techniques, our pressure-diffusion approach can provide a broad film thickness control range and extensive surface homogeneity. Supplementary Fig. S3 further illustrates the self-adhesion of a 200 µm thick CEAB film on the palm, showcasing its capability to replicate complex, curved surfaces over large areas. The 200 µm CEAB film demonstrates an impressive optical transmittance exceeding 95% between 400–800 nm wavelengths (Fig. 2 d). This exceptional transmittance results from macroscopic averaging of compositional and structural factors. Furthermore, a QR code enveloped by this CEAB film remains effortlessly scannable, as depicted in the inset of Fig. 2 d. Utilizing Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR) spectroscopy, we delineate the characteristic peaks of the CEAB film and discern their interactions (Fig. 2 e). CEAB film and EG show OH peak at 3307 cm − 1 and 3297 cm − 1 , this redshift of OH group indicates the hydrogen bond formation 53 , which is a characteristic of DES. For CEAB, both the ν(C = O) of AA and betaine shift to higher wavenumbers, while ν(C-N) of betaine shift to lower wavenumbers, suggesting the formation of [N(CH 3 ) 3 ] + :[COO − ] ion pairs 50 , 54 . Additionally, thermogravimetric analysis (TGA; Fig. 2 f) confirms the film's exceptional temperature stability, with minimal weight loss (< 5%) until 82.5°C, and a decomposition temperature nearing 240°C, suitable for high demanding conditions. Concurrently, differential scanning calorimetry (DSC) in Fig. 2 g establishes that the CEAB's glass transition temperature (Tg) remains below − 60°C, underscoring its flexibility even at low temperatures. Supplementary Fig. S4 further demonstrates the flexibility of 2 mm thick CEAB film that it can be easily twisted at both 25 ℃ and − 30 ℃. Figure 2 h reveals that, in contrast to Ag/AgCl hydrogel, the CEAB gel exhibits a weight increase of approximately 15% at 60% relative humidity (RH) and experiences minimal weight loss (below 5%) at 10% RH over 7 days. This result underscores the CEAB film's potential for effective epidermal moisture retention. Figure 2 i details the temperature-dependent ionic conductivity within a range of -50 to 60°C. To determine the electrical conductivity (σ) of CEAB film, the formula σ = d/RS is employed, where d represents the gel thickness, S signifies the gel area, and R denotes the value where the plot intersects the Z' axis. As temperature ascends, CEAB exhibits enhanced conductivity; for instance, its conductivity registers as 1.69 × 10 − 2 , 1.33, and 8.18 mS·cm − 1 at temperatures of -25°C, 25°C, and 60°C respectively (Supplementary Fig. S5a). Besides, the ionic conductivity's temperature dependency follows with the Vogel − Fulcher − Tammann (VFT) relationship 55 , demonstrating a robust congruence between theory and empirical findings (Supplementary Fig. S5b). Such elevated conductivities arise from rapid proton migration within the CEAB at high temperatures, inferred from its composition. DES contains ionized components such as hydrogen donors and hydrogen acceptors, which offer more protons to increase the conductivity. In addition, the low melting point of DES contributes to the free mobility of the protons, thus providing high conductivity of CEAB. Mechanical properties and self-healing ability Mechanical properties akin to the skin are pivotal for the application of epidermal electrodes, serving as a seamless interface between skin and electronics 14 , 15 . To evaluate the mechanical attributes of the CEAB film, a uniaxial tensile setup is employed. The true stress-strain curve (Fig. 3 a) of the CEAB film, varying in thickness, reveals strain-stiffening behaviors reminiscent of skin. This indicates the film presents a soft texture upon initial touch but swiftly stiffens, safeguarding against damage under elevated strains. Additionally, Young’s moduli of the CEAB films range from 3.23 to 59.74 kPa, aligning with values measured in the fibrous dermis (35–150 kPa) and the hypodermis (2 kPa) 56 . As delineated in Supplementary Table 2, Young’s modulus increases twentyfold as the film's thickness dwindles from 500 µm (3.23 kPa) to 3.55 µm (59.74 kPa). This enhancement stems from denser cross-linking for thinner precursors under identical UV exposure durations. Impressively, the CEAB film can stretch approximately 800% (engineering strain) of its original length without exhibiting discernible mechanical failure, a capability aligning well with on-skin electronics requirements, given that skin typically endures a maximum strain of around 30% 56 . CEAB gel demonstrates rapid self-healing attributes, which meet the requirement of an ideal epidermal electrode that self-recovers from external mechanical damage. As depicted in Fig. 3 b, the scar on the CEAB film vanishes entirely within 10 minutes at room temperature, with bubbles near the scar dissipating within 8 hours (Supplementary Movie 2). This self-healing process is attributed to the electrostatic interaction in betaine, reversible H-bonds in ChCl, EG, and polyacrylic acid, facilitating polymer chain diffusion at the interfaces. To assess CEAB film's self-adhesion on porcine skin, a 90° peeling experiment is conducted, as illustrated in Fig. 3 c. Within a thickness range from 3.55 µm to 500 µm, the CEAB exhibits a peeling interface toughness ranging between 5–20 J/m 2 , demonstrating strong adhesive capability for artifact-resistant epidermal electrical signal collection during movement. Supplementary Fig. S6a-d further verifies the strong adhesion to plastic tubes, paper, PET film, and rubber gloves respectively. Concurrently, the 500 µm CEAB film demonstrates a shear strength of 63 kPa on the porcine skin (Fig. 3 d), translating to a maximal shear force of 12.60 N—70 times of the 90° peel force (0.18N). Despite its superior adhesive qualities, the CEAB film allows for effortless and comfortable removal, as depicted in Fig. 3 e. Unlike conventional tapes (3M VHB) that often induce discomfort due to excessive adhesion and residual islands, the CEAB film ensures a user-friendly detachment. Conformability and biocompatibility CEAB films demonstrate remarkable conformability across diverse rough surfaces. Two primary factors influencing a material's conformability are its Young’s modulus and thickness; a decrease in both parameters enhances the material's ability to conform to irregular surfaces 57 . Supplementary Fig. S7a-d reveal that both 50 µm and 200 µm CEAB films adhere tightly to human skin due to their ultrasoft nature, fostered by hydrogen bonding on both the electrode-skin boundary and internal electrode, as well as weak electrostatic interactions in the electrode. These CEAB films readily accommodate skin deformations, such as stretching and squeezing. In Supplementary Fig. S8a-c, a 50 µm CEAB film affixed to the dorsal hand synchronizes with skin movements seamlessly—elongating upon stretching and forming wrinkles similar to skin creases during compression. In contrast, a 50 µm PET adhesive tape partially loses contact with the skin, failing to emulate the skin's subtle wrinkles due to modulus disparities between the skin and the PET film. Additionally, the 50 µm CEAB film exhibits conformal adhesion to fruit peels, including apples and avocados, as depicted in Supplementary Fig. S9, whereas PET tape demonstrates partial attachment from these fruit surfaces. Besides, since the geometry of the glyphic patterns at hands varies at the different locations, 3.55 µm and 200 µm thick CEAB film are attached to different regions of the hand to investigate the local texture conformability, including distal phalanges, proximal phalanges, metacarpophalangeal, and palm. Silicon rubber is used as the human hand replica, and bare skin without an attached electrode is captured to demonstrate the primitive morphology. As depicted in Fig. 4 a, with 3.55 µm thick CEAB film covering the surface, glyphic lines on proximal phalanges and metacarpophalangeal, including primary, secondary, tertiary, and even quaternary lines can be distinguished under the optical microscope. Additionally, the 3.55 µm thick CEAB film precisely conforms to the ridges and valleys, revealing fine structures including dense and directionally varying grooves, as well as irregular elevations between furrows with high resolution. The intimate contact between the fingerprint replica and 3.55 µm CEAB film is further investigated using SEM (Fig. 4 b), which reveals a secure adherence of the 3.55 µm CEAB film to the fingerprint replica, indicating distinct ridges and valleys with no detectable formation of air gaps. However, as the thickness of the CEAB film increases to 200 µm, the ability to discern fine structures such as grooves and papules is restricted due to a size mismatch; specifically, the depth between ridges and valleys is typically less than 60 µm 58 . Nonetheless, covered by the 200 µm CEAB film, the ridges, and valleys on the distal phalanges and palm remain discernible due to their ultrasoft mechanical properties. In agreement with optical images, ridges, and valleys can be discerned on the metacarpophalangeal replica covered by 200 µm CEAB film, with no observable air gaps due to the ultrasoft mechanical properties. The cytotoxicity assay with NIH3T3 cells proves the biocompatibility of CEAB gel that is suitable for on-skin applications (Fig. 4 c). As depicted in Fig. 4 d, for both the control group and the CEAB-conditioned group, NIH3T3 fibroblasts exhibit a flattened morphology after 12-hour incubation, followed by the development of fine cytoplasmic extensions after 24 hours of incubation. The water vapor transmission ability of CEAB film is compared with common interactive materials for human-machine interface substrates, such as PDMS and Parylene. After 5 days, CEAB had nearly 50% water vapor transmission, while PDMS and PET only had 10% or less water vapor transmission (Fig. 4 e). This indicates that CEAB film, as a wearable electrode material, will not block the skin surface and affect skin respiration. We summarize the overall comparison of our CEAB film with the most representative ionic gels in Supplementary Table 3. Electrode/skin contact impedance and epidermal biopotential detection The electrode/skin contact impedance within 1 h of the CEAB electrode is measured in the frequency range of 1-10 4 Hz. The CEAB electrode shows stable electrode/skin contact impedance (Supplementary Fig. S10a). The average electrode/skin impedance with 1 h of CEAB electrode is much lower than the commercial Ag/AgCl gel electrode, i.e., 284.259 kΩ, 1873.981 kΩ for the former and 337.698 kΩ, 2450.774 kΩ for the latter at 100 Hz and 10 Hz, respectively (Supplementary Fig. S10b). Stable and lower electrode/skin contact impedance contributes to high-quality biopotential acquisition. The wearable 200 µm CEAB electrodes are employed to investigate epidermal ECG, EMG, and EEG. Figure 1 d illustrates two CEAB electrodes attached to a volunteer's chest for ECG signal recording. Notably, rhythm-related parameters—including P, Q, R, S, and T waves—are distinctly identifiable in both static and dynamic states, crucial for clinical diagnoses 59 , as shown in Fig. 5 a. In contrast, the Ag/AgCl gel electrode exhibits higher noise levels and unstable peaks during motion. Benefitting from its robust adhesion and conformability, the CEAB electrode has superior signal-to-noise ratios (SNR) of 32.7 dB and 29.9 dB in static and dynamic states, respectively, surpassing the 28.0 dB and 18.8 dB of the Ag/AgCl gel electrode, as depicted in Fig. 5 b. This performance underscores the CEAB electrode's resilience against motion artifacts. Additionally, to capture muscle biopotentials, two CEAB electrodes are affixed to the forearm as working electrodes, while one is placed on the elbow as a reference electrode. By sustaining a grip force of 50 N, we assess the SNR and noise level of CEAB electrodes during EMG signal acquisition. Figure 5 c illustrates the noise analysis using RMS (root mean square) on baseline signals acquired during rest periods. The average noise level of the CEAB electrode (21.7 µV) is reduced by 33.6% over the 3.5 h monitoring period compared to the Ag/AgCl gel electrode (32.7 µV). Furthermore, the CEAB electrodes consistently outperform Ag/AgCl gel electrodes in SNR, averaging 12.5 dB—a 48.9% improvement over the 18.7 dB of the Ag/AgCl gel electrodes. This evidence solidifies that CEAB electrodes offer superior noise reduction and enhanced SNR compared to commercially available Ag/AgCl gel electrodes. Subsequent tests involving varied grip forces of 50 N, 320 N, and 650 N confirm that EMG signals remain distinguishable, aligning with the Ag/AgCl gel electrodes (Fig. 5 d). Notably, the CEAB electrode captures more stable EMG signals with minimal baseline fluctuations, demonstrating superior reliability. Supplementary Fig. S11 further illustrates that CEAB electrodes effectively differentiate EMG signals across various hand gestures, essential for human-machine interface applications. Coincidently, Supplementary Movie 3 further demonstrates the EMG signals of the forearm during various single-finger and hand movements. The facial muscles typically exhibit non-uniform distribution, and facial skin is prone to wrinkles development with facial expressions, undergoing substantial deformation 60 . Acquiring stable and high-quality facial EMG signals using flexible electrodes with excellent conformality remains a significant challenge. To ascertain the efficacy of CEAB electrodes as proficient facial EMG electrodes, we collect facial EMG data during volunteers' smiling episodes, with Ag/AgCl gel electrodes serving as a reference. As illustrated in Fig. 5 e, both electrodes demonstrate the capability to capture signals of good quality during volunteer smiles. However, the CEAB electrodes exhibit lower baseline noise. Throughout the entire data-acquisition process, the signals acquired by the CEAB electrodes have consistent baseline noise levels. In contrast, with an increasing time of smiles, substantial noise emerges between adjacent peaks for the Ag/AgCl gel electrode after 4 seconds. This occurrence can be attributed to the wrinkles induced by smiling, leading to motion artifacts between the Ag/AgCl gel electrode and the skin surface. The superior stretching ability and Young's modulus comparable to that of the skin of CEAB film facilitate accurate EMG signal acquisition, particularly during facial motion. Given the CEAB electrode's superior resistance to motion artifacts, minimal baseline noise, and enhanced SNR compared to Ag/AgCl gel electrodes, we utilize it for long-term EEG recordings on a volunteer, spanning up to 12 hours. Throughout this long duration, the volunteer is engaged in varied activities, including sleep, exercise, and relaxation. Notably, the quality of EEG signals remains consistent, even when the volunteer perspires during physical activities. Figure 5 f illustrates three distinct EEG signals corresponding to different mental states: heightened activity during exercise and reduced activity during sleep. By employing fast-Fourier transformation (FFT), we segment the EEG brainwaves into specific frequency bands: δ (0-2.5 Hz), θ (3.5–6.75 Hz), α (7.5-11.75 Hz), β (13–30 Hz), and γ (31–50 Hz) 61 . The β waves, are associated with increased energy levels and can reflect the degree of mental concentration and physical involvement 62 , 63 . Then we extract the β wave from the signal and compare the discrepancy. As depicted in Fig. 5 g, the intensity of β wave during exercise state is much stronger than that at rest or sleep status, which accords with the fact that β usually increases during physical exertion. Clinical detection and depression detection The knee jerk reflex is classified as a monosynaptic stretch reflex. In clinical settings 64 , tendon reflex examinations are commonly employed to assess the circuit integrity of the stretch reflex arc and to evaluate motor neuron functionality. To diagnose spinal pathway function, we affix CEAB electrodes to a healthy volunteer's thigh muscle. Consistent with hospital tests, when the kneecap is tapped with a small hammer, the CEAB electrodes capture a rapid surge in muscle electrophysiological activity, as depicted in Fig. 6 a. This observation aligns with findings from clinical studies and literature. Moreover, the CEAB electrodes monitor voluntary thigh muscle contractions during leg extensions. Unlike the knee-jerk reflex, these stronger contractions manifest larger amplitudes and prolonged durations due to the engagement of multiple motor units, resulting in more pronounced motor unit action potentials, as illustrated in Fig. 6 b. Depression is a severe mental disorder characterized by persistent feelings of sadness and potential suicidal tendencies 65 , 66 . According to the World Health Organization (WHO), as of 2023, over 264 million people globally are afflicted with depression, underscoring the urgency for early diagnosis and intervention 67 . Given EEG‘s ability to provide a direct reflection of brain neurological activity with high temporal resolution, EEG is increasingly recognized as a potent tool for non-invasive depression diagnosis 68 , 69 . Utilizing the CEAB electrode, we have designed a machine-learning approach to analyze single-channel EEG data of subjects at rest state, facilitating swift and reliable depression diagnosis, as depicted in Fig. 6 c-f. Specifically, real-time data collection is conducted, followed by preprocessing with Python 3.8. EEG signals inherently display temporal variability and dynamics, and different frequency components correspond to different temporal and physiological states 70 . To build extensive training datasets for machine learning, we segment the EEG data into 2-second intervals, incorporating a 50% overlap to capture the intricate and dynamic attributes of EEG effectively (Fig. 6 c). This windowing strategy has been demonstrated to encapsulate relevant information across varied EEG types, thereby enhancing classification outcomes 71 . Our dataset encompasses 633 samples, balanced between healthy and depression-afflicted samples. As showcased in Fig. 6 d, we apply FFT to the original EEG signals, delineating frequency bands and deriving eSense values via NeuroSky's algorithm 72 , 73 . This algorithm can express the mental state information (attention and meditation) of the human brain with eSense values. Then we extract two distinct feature categories from the EEG data: linear attributes, including Variance, Absolute Power, Mean, and Coherence, juxtaposed against nonlinear attributes like Entropy and C0-Complexity 74 (Fig. 6 e). Linear features contain signal specificity, whereas nonlinear attributes underscore intricacy and stability 74 . Subsequently, these features are concatenated and then input into a range of classifiers, namely Supporting Vector Machine (SVM) 75 , K-Nearest Neighbor (KNN) 76 , XGBoost 77 , and Random Forest (RF) 78 for depression detection (Fig. 6 f). As illustrated in Table 1 , the RF performs the best accuracy of 92.91%, recall of 92.91%, and precision of 93.19% on test dataset. Figure 6 g further illustrates the confusion matrix of RF models on depression prediction. Table 1 Machine Learning model results. KNN XGBoost SVM RF Precision 89.78% 89.78% 69.28% 93.19% Recall 89.76% 89.76% 69.29% 92.91% F1 score 89.77% 89.77% 69.28% 92.91% To delve deeper into understanding feature contributions for predicting depression, we employed the Gini importance method within scikit-learn for enhanced feature analysis 79 . Utilizing the RF model, individual feature importance is computed and graphically depicted in Supplementary Fig. S12. The histogram highlights four paramount features: mean attention, standard deviation σ, mean of the low γ band, and mean of the δ band (Supplementary Fig. S13a-d). Approximately 80% of individuals with depression exhibit diminished attention compared to healthy counterparts. Furthermore, ~ 20% of samples manifest higher σ, where higher variance indicates greater emotion change among subjects with depression 80 . Notably, the low γ band's sensitivity to emotional nuances indicates a trend that a majority of depression patients register elevated low γ values, thereby identifying these metrics as potential depression biomarkers 81 , 82 . Additionally, over 80% of depression samples have lower mean δ values, which is correlated to heightened psychological distress, potentially amplifying depression vulnerability 83 . Leveraging CEAB electrodes, we build a single-channel RF model finding digital depression biomarkers. EEG with CEAB electrodes offers an efficient, user-friendly, and feasible solution for depression detection via a single-channel wearable EEG headband. Hand gesture replication by robotic hands Hand gestures play a pivotal role in conveying concise messages and carrying emotional implications, making them essential in both realistic and digital communication, especially within human-machine interaction applications 84 . While traditional methods of gesture sensing and recognition primarily depend on algorithms to semantically interpret images or videos 85 – 88 , they often face challenges due to environmental interferences such as obstructed objects and varying lighting conditions 89 . Unlike traditional methods, EMG, which captures signals before muscle contraction, provides a robust solution for hand gesture recognition without interference from external environmental factors 90 . We utilize CEAB electrodes to record forearm EMG signals from volunteers performing six distinct hand gestures. The captured signals are subsequently combined with sophisticated algorithms and embedded techniques to instruct robotic arms to mimic the recorded hand movements. Firstly, we collect an EMG dataset of different gestures from volunteers, encompassing categories of "rest", "six", "eight", "good", "yeah", "ok", and "fist". These samples are carefully segmented into intervals with 1000 data points with a 95% overlap, strategically designed to augment the dataset and encapsulate essential biopotential information related to gesture motion. Subsequently, we establish a two-layer Convolutional Neural Network (CNN) model tailored for efficient gesture classification. Figure 7 a provides a visual representation of this CNN model's architecture. The analysis begins by reshaping the input data into a 2D array, followed by convolutional and pooling layers to extract pertinent features. The following steps include flattening and deploying dense layers to achieve multi-label classification. Figure 7 b presents the confusion matrix results for gesture recognition, where the predicted and actual type counts are consistent, differing only in one or two instances. The training loss and accuracy are shown in Supplementary Fig. S14, highlighting the model's gesture recognition capabilities. Our results achieve 99.78% for precision, recall, and accuracy due to larger signal differences (Supplementary Fig. S11b) captured by CEAB electrodes among various gestures. Subsequently, we utilize the algorithm to recognize gestures and instruct the robotic arms to replicate human gestures. Upon feeding the forearm biopotential data of various gestures into the trained models, the system returns a predicted label in approximately 150 ms. This label is then relayed to the robotic arm, instructing it to execute the corresponding gesture. To account for the time delay required for the robotic arm's movement, we set an appropriate delay before accepting the subsequent EMG input. Figure 7 c-e demonstrates the hand gestures replication by the robotic arm. Details of forearm biopotential driving the robotic arm to imitate human gestures can be found in Supplementary Movie 4. Discussions In conclusion, our study develops an ionic, flexible, dry, and self-healing electrode, named CEAB, through the utilization of deep eutectic solvents (DESs) and ionically cooperative conductors. We propose a streamlined method for crafting an ultrathin ionic electrode film, achieving a thickness of as small as 3.55 μm. The CEAB electrode has exceptional attributes, including high conductivity, minimized noise levels, and the uninterrupted capture of epidermal biopotential signals (e.g., ECG, sEMG, EEG) during dynamic detection. Through seamless integration with digital signal processing and analysis algorithms, using a one-channel wearable device, the electrode adeptly identifies abnormal EEG signals associated with depressive patients in clinical scenarios. Furthermore, this integration enables hand gesture repetition by robotic arms based on EMG signals, underscoring the transformative potential of this technology in health monitoring and human-machine interactions. Methods Materials Choline chloride (ChCl) (AR, 98%), Ethylene Glycol (AR, ≥ 99%), Acrylic acid (AA) (AR, ≥ 99%), Betaine (AR, 98%), Irgacure 2959 (AR, 98%), were all purchased Shanghai Macklin Biochemical Company (China). All reagents are used without further purification. Preparation of CEAB film To prepare the deep eutectic solvent (DES), we first mixed the hydrogen bond acceptor, choline chloride (ChCl), and the hydrogen bond donor, EG, in a 1:2 molar ratio. Following this, the mixture was stirred at 100 °C for 2 hours. Then, acrylic acid (AA) was dissolved in the DES. Subsequently, we added betaine and Irgacure 2959 to the solution and vigorously stirred the mixture for 1 hour until it dissolved completely, resulting in a clear precursor solution. The precursor solution consisted of ChCl, EG, AA, and betaine in a molar ratio of 2:4:4:1, and the weight percentage of 2959 was 0.1%. Afterward, the solution was allowed to stand overnight to eliminate all bubbles. Next, we coated the CEAB precursor between two PET release membranes pre-treated with silicone oil and affixed it to the surface of a flat glass mold. Afterward, another flat glass was positioned above. Uniform pressure was applied to the surface glass, and the duration was set as 5 min. The thickness of the precursor layer could be controlled by adjusting the pressure and duration applied to the glass surface. Finally, the glass mold was placed 5 centimeters above a 365-nanometer UV lamp with an output of 10 watts and exposure of 5 minutes. After photopolymerization, we rapidly removed the support PET film to obtain an independent ultra-thin organic gel film. Scanning electron microscope (SEM) The gross morphology of a freeze-dried CEAB film was observed via the Hitachi SU8010 under an accelerating voltage of 5 kV. The gel samples were then freeze-dried for 24 hours and sputter-coated with gold before imaging. For the gel/skin replica samples, a 3.55 and 200 µm gel film was cut into small pieces with sharp edges and then directly attached to an EcoflexTM rubber skin replica. To remove the remaining organic solvent, all samples were freeze-dried before being introduced to the SEM chamber. Fourier Transform Infrared Spectroscopy (FTIR) The samples were dried in a vacuum drying oven before testing. FTIR spectra of the samples were recorded using a spectrometer (Thermo Scientific Nicolet™ iS50) within the wavenumber range of 400 to 4000 cm -1 . Thermogravimetric Analysis (TGA) After drying the gels, thermodynamic properties were analyzed using a thermogravimetric analyzer (NETZSCH's STA 449 F3 Jupiter®). The initial mass of the sample was 5-10 mg, and it was heated from room temperature to 600 ℃ at a rate of 10 ℃/min under a nitrogen (N 2 ) atmosphere. Differential Scanning Calorimeter (DSC) The thermal transition behavior of the polymers was investigated using differential scanning calorimetry (Mettler-Toledo DSC 3). The initial mass of the sample was 20-50 mg, and heating was performed at a rate of 10 ℃/min within the temperature range of –60 to 100 ℃ under a nitrogen (N 2 ) atmosphere. In the freezing stretch tests, Ag/AgCl gel and CEAB samples (6 cm in length, 1 cm in width, and 200 μm in thickness) were exposed to -30 ℃ for a duration of 24 hours. Following this cold exposure, the samples were twisted to assess their flexibility. For the moisture retention tests, CEAB and Ag/AgCl gels with identical weight and shape were kept at consistent temperatures of 37 ℃, while exposing them to varying relative humidity levels (RH: 10 % and 60 %) for a duration of 7 days. The weight of the samples was recorded at different time intervals during the test. Weight loss was calculated using the following formula: Weight percent (%) =*100 % Here, represents the initial weight of the gel, and is the weight after storage at a specific time. Electrical Measurement To determine the ionic conductivities of the materials, we performed complex impedance measurements using an electrochemical workstation (PARSTAT 4000A, Princeton) across a frequency range from 0.1 Hz to 1 MHz, employing an alternating-current sine wave with an amplitude of 500 mV. In this procedure, a CEAB sample was cut into a cylindrical shape with dimensions of 6 mm in diameter and 3 mm in depth, and it was placed between two round steel electrodes. The material was kept at the specific temperature of -25, -20, 0, 20, 25, 40, and 60 ℃ for 30 min before testing. To obtain the bulk resistance (R) of the materials, we identified the intercept on the real axis of the Nyquist plot at a high frequency, utilizing the Z-view software. Subsequently, the conductivity of the CEAB was calculated using the formula σ = L / (A·R), where L represents the distance between the electrodes, and a signifies the cross-sectional area of the sample. Evaluation of Mechanical Properties The tensile mechanical properties were assessed through uniaxial tensile and unconfined compression tests conducted using a LISHI LE3104 setup with a 10 N loading capacity. Different thickness of 3.55, 50, 150, 250, and 500 μm CEAB film was cut to dimensions of 100 mm × 20 mm. To prevent the occurrence of cracks at the clamping positions, both ends of the sample were securely attached to two pieces of paper before being connected to the fixture. The test was conducted with a consistent peeling speed of 30 mm/min. For the assessment of interfacial adhesion properties, we employed a 90° peel-off test, as introduced in Supplementary Fig. S13 and Supplementary Movie S4 in the Supporting Information. In this evaluation, a 3.55, 50, 250, and 500 µm thick CEAB film, cut to dimensions of 100 mm × 20 mm, was securely attached to a fresh porcine skin specimen, respectively. The test was conducted with a consistent peeling speed of 30 mm/min. Evaluation of Self-Healing Property The precursor was cured for 5 min under UV light. After the photoreaction, a piece of elongated hydrogel was cut into two sections, which were then covered. After 8 hours, the two sections are completely self-healed under a photomicroscope. In vitro Biocompatibility Testing The biocompatibility of CEAB gel was assessed in vitro using the assay (CCK-8 kit, Yeasen, Guangzhou, China). A piece of CEAB gel (2.0 g) is immersed in 10 mL of deionized water for 24 h at room temperature. Then the mouse embryonic fibroblasts cell line (NIH3T3) was plated in a 96-well plate (2000 cells/well) with six parallel Wells (n=6) in which NIH3T3 cells were cultured in Dulbecco's Modified Eagle Medium (DMEM) medium (HyClone, USA) and complete growth medium with 10% fetal bovine serum, 100 U mL-1 penicillin and 0.1 mg mL-1 streptomycin (Thermo Fisher Scientific, USA) at 37 ° C in 5% CO 2 . The total volume of the medium used in this work was 100 uL. After 12h of cell culture, 10 μL CEAB gel extract was added to the medium, and the cells were then incubated at 37 ℃ for 24 h. At the time point to be measured, CCK-8 (10 μL), 10% of the total volume of the medium, was added and incubated for 2h in the dark. The absorbance of the 96-well plate was measured at 450 nm using a microplate reader (Tecan MicroplateReader Spark, USA). The cell viability is calculated according to the formula. The blank control was not seeded with NIH3T3 cells in the 96-well plate, and the negative control was only added DMEM complete medium after seeding NIH3T3 cells in the 96-well plate. Where OD S , OD C , and OD N were the OD values of the samples, blank control, and negative control, respectively. Cell Recovery The frozen storage tube containing 1 mL of cell suspension was quickly shaken and thawed in a 37 ℃-water bath, and 4 mL of medium was added to mix well. Centrifuge at 1000 rpm for 3 min, discard the supernatant, add 1-2 mL culture medium, and then blow well. All cell suspensions were then added to a culture dish with an appropriate complete culture medium. Cell Passage Discard the upper culture medium and rinse the cells with calcium- and magnesium-free PBS 1-2 times. Add 1 mL of digestion solution (0.25% Trypsin-0.53mM EDTA) to the culture flask, and place the culture flask in a 37°C incubator for 1 min. Then 2-3 mL of complete culture medium is added to terminate digestion. After quick, gentle mixing, transfer the contents to a sterile centrifuge tube, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, add 1-2 mL of culture medium, and resuspend the cells with the appropriate complete culture medium in new culture dishes. Water Vapor Transmission Rate (WVTR) test Water vapor permeability was evaluated by measuring the weight of water in a bottle where the opening was covered by the target films. Pure water (1 g) was placed in a sample bottle with a diameter of 15 mm. The CEAB gel film (200μm) was attached to the opening of the bottle with an adhesive (Araldite, Nichiban). This bottle was stored in a thermostatic chamber at 25 ℃ and a humidity of 42% for 5 days, and the subsequent decrease in weight was measured. As a comparison sample, a 4-µm-thick Parylene film, and a 50-μm-thick PDMS layer film were used. A bottle without any covering was used as the reference sample. Electrode/skin contact impedance and biopotential signals extraction The electrode/skin contact impedance was measured by positioning two electrodes, namely commercial Ag/AgCl gel electrodes (1 mm, 1.77 cm²) or CEAB electrodes (1.5 mm, 1.77 cm²), at a distance of 7 cm on the anterior surface of a volunteer's forearm. These electrodes were then linked to the electrochemical workstation (CHI 760E). Impedance spectra were captured within the frequency range of 1 to 10 4 Hz, with the AC voltage amplitude fixed at 0.1 V. The EMG signal recording setup comprises two main components: a microcontroller (Arduino UNO microcontroller) and a detector (Muscle SpikerBox Pro). The EMG signals are captured by the Spikershield box through potential differences between the working electrodes on the target area and the reference electrodes. Signal processing algorithms are applied to the collected data using Python for fundamental signal analysis (Root-Mean-Square). The ECG data acquisition device employs a portable, wearable chest adhesive ECG sensor based on the BMD101 chip. The BMD101 chip comprises two main components: a low-noise amplifier and an ADC (Analog-to-Digital Converter). These components work in tandem, with the BMD101 chip capturing and amplifying faint bioelectrical signals originating from the heart via chest electrodes. Once the ECG signals are converted into digital form by the ADC, the BMD101 chip processes them digitally, including tasks like filtering, sampling, and data compression. Finally, the chip transmits the data to a smartphone via Bluetooth, enabling real-time monitoring of cardiac activity and subsequent recording and analysis. The ECG signals were analyzed using the Python envelope function. In EMG testing, in cases recording the grip force muscle potential and collecting EMG signals during various hand gestures, two CEAB electrodes were placed on the forearm, with a CEAB film used as the reference electrode on the posterior elbow. These electrodes recorded signals generated by the brachioradialis muscle. For cases involving the collection of EMG signals during knee reflex tests, two CEAB electrodes were positioned on the anterior thigh, and a CEAB film was applied to the knee as the reference electrode. These electrodes captured signals generated by the quadriceps muscle. In cases where EMG signals during finger flexion and extension were collected, two CEAB electrodes were positioned on the forearm. In cases where facial EMG is collected when a volunteer smiles, two CEAB electrodes are attached to the risorius and zygomaticus, and a reference CEAB electrode is attached behind the ear. The Ag/AgCl gel electrodes are also attached to the same locations in the cases as the comparison. The ECG signals were acquired by placing two CEAB film electrodes in specific positions: one below the clavicle, in the 3rd intercostal space, near the heart, and the other in a position symmetrically aligned with the midline of the chest. Subsequently, these electrodes were connected to an ECG sensor based on the BMD101 chip's signal recording device. The acquired ECG signals could then be monitored in real time on a laptop and subsequently analyzed using Python's envelope function. In EEG measurements, CEAB electrodes were positioned according to the 10-20 system for electrode placement on the head. The CEAB electrode was located at the FP1 site (at the left side of the forehead) as the working electrode, with the FPz site (at the frontal region of the brain) serving as the reference electrode. Another CEAB film electrode was placed behind the ear to serve as the ground electrode. Motion artifact characterization. The electromechanical vibrator was placed near the working electrodes (about 2 cm) to induce skin vibration, which is similar to vibration near the chest during body movement. Long-time monitoring of EEG Brain activity was assessed using EEG signals recorded with an ECG sensor based on the BMD101 chip. The working electrode was positioned at the FP1 site, the reference electrode at the FPz site, and the ground electrode behind the ear. During the 12-hour monitoring period, the volunteer slept for 1 hour, engaged in 0.5 hours of exercise, and finally returned to a state of calm without removing the CEAB electrodes. Subsequently, the EEG signal is analyzed using Python and Fast Fourier Transformation. Depression detection Depression data collection. We recruited 6 depressed and 6 healthy volunteers from the Fifth Affiliated Hospital of Wenzhou Medical University in China (all the depressed volunteers were diagnosed by the Hamilton Depression Scale in the hospital). EEG signals were recorded by a portable TGAM EEG device with a single channel. The ring-shaped EEG sensor was tied to the head, and all people were asked to keep calm and their eyes closed for 1 minute without any interruption. Depression data preprocess. Building upon the TGAM module, the embedded algorithms filtered power line frequency noise. The dataset encompassed both the raw EEG original values and transformed values across various frequency bands. The data were firstly cleaned by deleting invalid “0” values received at the beginning stage, then aligned following the sampling frequency of 512 Hz. A 2-second duration of data was set as a sample, with an overlap of 50%. Features extraction. Twelve linear features including original value mean, original value σ (standard deviation), attention mean, attention σ, δ mean, θ mean, low α mean, high α mean, low β mean, high β mean, low γ mean, mid γ mean, low β mean / θ mean, high β mean / θ mean, and two nonlinear features including Co complexity and Power Spectral Entropy were extracted as features for normal, depression classification. Machine learning models construction. SVM, KNN, XGBOOST, and RF were constructed by sklearn toolkit, python 3.8. Hand gesture replication by robotic hands Gesture dataset collection. Ten volunteers are instructed to repeat six different gestures—six, eight, good, yeah, ok, and fist—each lasting 5 seconds, with a 5-second rest between consecutive gestures to prevent muscle fatigue. This entire sequence is collected over 1 minute and repeated for ten volunteers. Data preprocess. The gesture data is firstly sliced at the length of 1000, overlapped at 95%, normalized, and then reshaped as 20×50 dimension. CNN model construction. The CNN architecture is established by the Keras toolkit in Python 3.8. Declarations Authorship contribution Conceptualization: Zhenglin Chen, Likun Zhang, Dongmei Yu, Peiwu Qin Methodology: Likun Zhang, Huazhang Ying, Zhicheng Du, Ziwu Song, Jiaju Chen. Investigation: Zhenglin Chen, Likun Zhang. Visualization: Likun Zhang, Zhenglin Chen, Huazhang Ying, Xi Yuan, Ping Zhang, Jiaju Chen. Supervision: Dongmei Yu, Peiwu Qin, Zhenglin Chen, Chenggang Yan. Writing—original draft: Likun Zhang, Zhenglin chen. Writing—review & editing: Zhenglin Chen, Peiwu Qin, Wenbo Ding, Canhui Yang, Vijay Pandey, Xinhui Xing, Jiansong Ji, Chenggang Yan. Code availability The codes for EMG, EEG, ECG signal recording, and analysis used in this study are available from the corresponding authors upon request. Declaration of competing interest The authors declare that they have no competing interests. The authors claim that none of the material in the paper has been published or is under consideration for publication elsewhere. All authors have seen the manuscript and approved to submit to your journal. Ethical declaration The study protocol was thoroughly reviewed and approved by the ethical committee of the Tsinghua Shenzhen International Graduate School, Tsinghua University (approval number 2023-F036). Acknowledgments We thank the support from the National Natural Science Foundation of China 31970752,32350410397; Science, Technology, Innovation Commission of Shenzhen Municipality, JCYJ20220530143014032, JCYJ20230807113017035, WDZC20200820173710001, Shenzhen Medical Research Funds, D2301002; Department of Chemical Engineering-iBHE special cooperation joint fund project, DCE-iBHE-2022-3; Tsinghua Shenzhen International Graduate School Cross-disciplinary Research and Innovation Fund Research Plan, JC2022009; and Bureau of Planning, Land and Resources of Shenzhen Municipality (2022) 207. References Imani, S. et al. A wearable chemical–electrophysiological hybrid biosensing system for real-time health and fitness monitoring. 7, 11650 (2016). Liu, Y., Pharr, M. & Salvatore, G. A. Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring. ACS Nano 11, 9614–9635, doi: 10.1021/acsnano.7b04898 (2017). Jang, K.-I. et al. Self-assembled three dimensional network designs for soft electronics. 8, 15894 (2017). Zhou, Z., Zhang, H., Liu, J. & Huang, W. J. G. Flexible electronics from intrinsically soft materials. 6, 100051 (2021). Bihar, E. et al. Fully printed electrodes on stretchable textiles for long-term electrophysiology. 2, 1600251 (2017). Chen, Z., Wang, Y. J. S. & Diagnostics. Organic ionic fluid-based wearable sensors for healthcare. 1, 598–613 (2022). Zhao, Y. et al. Ultra-conformal skin electrodes with synergistically enhanced conductivity for long-time and low-motion artifact epidermal electrophysiology. 12, 4880 (2021). Kim, T. H. et al. Flexible biomimetic block copolymer composite for temperature and long-wave infrared sensing. 9, eade0423, doi:doi: 10.1126/sciadv.ade0423 (2023). Cheng, L., Li, J., Guo, A. & Zhang, J. Recent advances in flexible noninvasive electrodes for surface electromyography acquisition. npj Flexible Electronics 7, 39, doi: 10.1038/s41528-023-00273-0 (2023). Yuk, H., Wu, J. & Zhao, X. J. N. R. M. Hydrogel interfaces for merging humans and machines. 7, 935–952 (2022). Jinkins, K. R. et al. Thermally switchable, crystallizable oil and silicone composite adhesives for skin-interfaced wearable devices. 8, eabo0537, doi:doi: 10.1126/sciadv.abo0537 (2022). Chen, F. et al. Wet-Adaptive Electronic Skin. 35, 2305630 (2023). Hao, Y. et al. A Stretchable, Breathable, And Self-Adhesive Electronic Skin with Multimodal Sensing Capabilities for Human‐Centered Healthcare. 33, 2303881 (2023). Lim, C. et al. Stretchable conductive nanocomposite based on alginate hydrogel and silver nanowires for wearable electronics. 7 (2019). Lim, C. et al. Tissue-like skin-device interface for wearable bioelectronics by using ultrasoft, mass-permeable, and low-impedance hydrogels. 7, eabd3716 (2021). Wang, B. & Facchetti, A. J. A. M. Mechanically flexible conductors for stretchable and wearable e-skin and e‐textile devices. 31, 1901408 (2019). Wang, J. et al. Ultrastretchable E-Skin Based on Conductive Hydrogel Microfibers for Wearable Sensors. 2305951 (2023). Xun, X. et al. Highly robust and self-powered electronic skin based on tough conductive self-healing elastomer. 14, 9066–9072 (2020). Khatib, M., Zohar, O., Saliba, W. & Haick, H. J. A. M. A multifunctional electronic skin empowered with damage mapping and autonomic acceleration of self-healing in designated locations. 32, 2000246 (2020). Kang, J. et al. Tough and water-insensitive self‐healing elastomer for robust electronic skin. 30, 1706846 (2018). Lin, X. et al. Biocompatible multifunctional e-skins with excellent self-healing ability enabled by clean and scalable fabrication. 13, 1–14 (2021). Fernandez, M., Pallas-Areny, R. J. B. i. & technology. Ag-AgCl electrode noise in high-resolution ECG measurements. 34, 125–130 (2000). Huigen, E., Peper, A., Grimbergen, C. J. M., engineering, b. & computing. Investigation into the origin of the noise of surface electrodes. 40, 332–338 (2002). Meziane, N., Webster, J., Attari, M. & Nimunkar, A. J. P. m. Dry electrodes for electrocardiography. 34, R47 (2013). Chi, Y. M., Jung, T.-P. & Cauwenberghs, G. J. I. r. i. b. e. Dry-contact and noncontact biopotential electrodes: Methodological review. 3, 106–119 (2010). De Luca, C., Le Fever, R., Stulen, F. J. M., engineering, b. & computing. Pasteless electrode for clinical use. 17, 387–390 (1979). Hoffmann, K.-P., Ruff, R. & Poppendieck, W. in 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. 2239–2242 (IEEE). Fan, D. et al. Self-shrinking soft demoulding for complex high-aspect-ratio microchannels. 13, 5083 (2022). Chen, Z. et al. Temperature tolerant all-solid-state touch panel with high stretchablity, transparency and self-healing ability. 451, 138672 (2023). Zou, Y., Nathan, V., Jafari, R. J. I. j. o. b. & informatics, h. Automatic identification of artifact-related independent components for artifact removal in EEG recordings. 20, 73–81 (2014). Green, R. M. et al. Benefits, shortcomings, and costs of EEG monitoring. 201, 785 (1985). Rudiger, A., Hellermann, J. P., Mukherjee, R., Follath, F. & Turina, J. J. T. A. j. o. e. m. Electrocardiographic artifacts due to electrode misplacement and their frequency in different clinical settings. 25, 174–178 (2007). Nie, J., Fu, J. & He, Y. J. S. Hydrogels: the next generation body materials for microfluidic chips? 16, 2003797 (2020). Zainal, S. H. et al. Preparation of cellulose-based hydrogel: A review. 10, 935–952 (2021). Ohm, Y. et al. An electrically conductive silver–polyacrylamide–alginate hydrogel composite for soft electronics. 4, 185–192 (2021). Hu, C. et al. Stable, strain-sensitive conductive hydrogel with antifreezing capability, remoldability, and reusability. 10, 44000–44010 (2018). Zhao, X. et al. Bioinspired ultra-stretchable and anti-freezing conductive hydrogel fibers with ordered and reversible polymer chain alignment. 9, 3579 (2018). Han, L. et al. Mussel-inspired adhesive and conductive hydrogel with long‐lasting moisture and extreme temperature tolerance. 28, 1704195 (2018). Zhang, Q., Vigier, K. D. O., Royer, S. & Jérôme, F. J. C. S. R. Deep eutectic solvents: syntheses, properties and applications. 41, 7108–7146 (2012). Smith, E. L., Abbott, A. P. & Ryder, K. S. J. C. r. Deep eutectic solvents (DESs) and their applications. 114, 11060–11082 (2014). Stefanovic, R., Ludwig, M., Webber, G. B., Atkin, R. & Page, A. J. J. P. C. C. P. Nanostructure, hydrogen bonding and rheology in choline chloride deep eutectic solvents as a function of the hydrogen bond donor. 19, 3297–3306 (2017). Zhao, B.-Y. et al. Biocompatible deep eutectic solvents based on choline chloride: characterization and application to the extraction of rutin from Sophora japonica. 3, 2746–2755 (2015). Paiva, A. et al. Natural deep eutectic solvents–solvents for the 21st century. 2, 1063–1071 (2014). Qin, H., Owyeung, R. E., Sonkusale, S. R. & Panzer, M. J. J. J. o. M. C. C. Highly stretchable and nonvolatile gelatin-supported deep eutectic solvent gel electrolyte-based ionic skins for strain and pressure sensing. 7, 601–608 (2019). Lai, C.-W., Yu, S.-S. J. A. a. m. & interfaces. 3D printable strain sensors from deep eutectic solvents and cellulose nanocrystals. 12, 34235–34244 (2020). Li, G. et al. A stretchable and adhesive ionic conductor based on polyacrylic acid and deep eutectic solvents. npj Flexible Electronics 5, 23, doi: 10.1038/s41528-021-00118-8 (2021). Kang, J., Tok, J. B. H. & Bao, Z. Self-healing soft electronics. Nature Electronics 2, 144–150, doi: 10.1038/s41928-019-0235-0 (2019). Vatankhah-Varnosfaderani, M. et al. Chameleon-like elastomers with molecularly encoded strain-adaptive stiffening and coloration. Science 359, 1509–1513, doi: 10.1126/science.aar5308 (2018). Storm, C., Pastore, J. J., MacKintosh, F. C., Lubensky, T. C. & Janmey, P. A. Nonlinear elasticity in biological gels. Nature 435, 191–194, doi: 10.1038/nature03521 (2005). Zhang, W., Wu, B., Sun, S. & Wu, P. Skin-like mechanoresponsive self-healing ionic elastomer from supramolecular zwitterionic network. Nature Communications 12, 4082, doi: 10.1038/s41467-021-24382-4 (2021). Reilly, R. B., Lee, T. C. J. T. & Care, H. Electrograms (ecg, eeg, emg, eog). 18, 443–458 (2010). Cheng, S. et al. Ultrathin Hydrogel Films toward Breathable Skin-Integrated Electronics. 35, 2206793 (2023). Lim, C. Y. et al. Desulfurization performance of choline chloride-based deep eutectic solvents in the presence of graphene oxide. 7, 97 (2020). Sarma, A. V. et al. Solution NMR of a 463-residue phosphohexomutase: domain 4 mobility, substates, and phosphoryl transfer defect. 51, 807–819 (2012). Smedley, S. I. The interpretation of ionic conductivity in liquids . (Springer Science & Business Media, 2012). Guimarães, C. F., Gasperini, L., Marques, A. P. & Reis, R. L. The stiffness of living tissues and its implications for tissue engineering. Nature Reviews Materials 5, 351–370, doi: 10.1038/s41578-019-0169-1 (2020). Liu, S., Rao, Y., Jang, H., Tan, P. & Lu, N. J. M. Strategies for body-conformable electronics. 5, 1104–1136 (2022). Ashbaugh, D. R. Quantitative-qualitative friction ridge analysis: an introduction to basic and advanced ridgeology . (CRC press, 1999). Hurst, J. W. J. C. Naming of the waves in the ECG, with a brief account of their genesis. 98, 1937–1942 (1998). Fujimura, T., Hotta, M. J. S. R. & Technology. The preliminary study of the relationship between facial movements and wrinkle formation. 18, 219–224 (2012). Kandel, E. R. et al. Principles of neural science . Vol. 4 (McGraw-hill New York, 2000). Mari-Acevedo, J., Yelvington, K. & Tatum, W. O. in Handbook of Clinical Neurology Vol. 160 (eds Kerry H. Levin & Patrick Chauvel) 143–160 (Elsevier, 2019). French, J. A. in Rowan's Primer of EEG (Second Edition) (eds Lara V. Marcuse, Madeline C. Fields, & Jiyeoun Yoo) vii (Elsevier, 2016). Twitmyer, E. B. J. J. o. E. P. A study of the knee jerk. 103, 1047 (1974). Horwitz, A. V. & Wakefield, J. C. The loss of sadness: How psychiatry transformed normal sorrow into depressive disorder . (Oxford University Press, 2007). Fekadu, N., Shibeshi, W. & Engidawork, E. J. J. D. A. Major depressive disorder: pathophysiology and clinical management. 6, 255–257 (2017). Baroiu, L. et al. Assessment of Depression in Patients with COVID-19. 12, 254–264 (2021). de Aguiar Neto, F. S., Rosa, J. L. G. J. N. & Reviews, B. Depression biomarkers using non-invasive EEG: A review. 105, 83–93 (2019). Voetterl, H. T. S. et al. Alpha peak frequency-based Brainmarker-I as a method to stratify to pharmacotherapy and brain stimulation treatments in depression. Nature Mental Health 1, 1023–1032, doi: 10.1038/s44220-023-00160-7 (2023). Márton, L., Brassai, S. T., Bakó, L. & Losonczi, L. J. P. T. Detrended fluctuation analysis of EEG signals. 12, 125–132 (2014). Duan, L. et al. Machine learning approaches for MDD detection and emotion decoding using EEG signals. 14, 284 (2020). Yin, L., Zhang, C. & Cui, Z. J. C. C. Experimental research on real-time acquisition and monitoring of wearable EEG based on TGAM module. 151, 76–85 (2020). Wu, Y., Xie, N. J. C. & Medicine, M. M. i. Attention Optimization Method for EEG via the TGAM. 2020 (2020). Acharya, U. R. et al. Computer-aided diagnosis of depression using EEG signals. 73, 329–336 (2015). Huang, S. et al. Applications of support vector machine (SVM) learning in cancer genomics. 15, 41–51 (2018). Cai, H. et al. Feature-level fusion approaches based on multimodal EEG data for depression recognition. 59, 127–138 (2020). Zulfiker, M. S., Kabir, N., Biswas, A. A., Nazneen, T. & Uddin, M. S. J. C. r. i. b. s. An in-depth analysis of machine learning approaches to predict depression. 2, 100044 (2021). Cacheda, F., Fernandez, D., Novoa, F. J. & Carneiro, V. J. J. o. m. I. r. Early detection of depression: social network analysis and random forest techniques. 21, e12554 (2019). Menze, B. H. et al. A comparison of random forest and its Gini importance with standard chemometric methods for the feature selection and classification of spectral data. 10, 1–16 (2009). Jamal, R. & Kullar, M. Multivariate Time-Series Signals of Affect Dynamics and Neural Oscillations with Suggested Applications to Technology to Identify Depression Risk. (2022). Roh, S.-C., Park, E.-J., Shim, M. & Lee, S.-H. J. J. o. a. d. EEG beta and low gamma power correlates with inattention in patients with major depressive disorder. 204, 124–130 (2016). Watts, D. et al. Predicting treatment response using EEG in major depressive disorder: A machine-learning meta-analysis. 12, 332 (2022). Meerwijk, E. L., Ford, J. M. & Weiss, S. J. J. B. p. Resting-state EEG delta power is associated with psychological pain in adults with a history of depression. 105, 106–114 (2015). De Stefani, E. & De Marco, D. J. F. i. P. Language, gesture, and emotional communication: An embodied view of social interaction. 10, 2063 (2019). Zhang, R. et al. RCMNet: A deep learning model assists CAR-T therapy for leukemia. 150, 106084 (2022). Bhardwaj, V. et al. Machine learning for endometrial cancer prediction and prognostication. 12, 852746 (2022). Liu, Y. et al. Mixed-UNet: Refined class activation mapping for weakly-supervised semantic segmentation with multi-scale inference. 4, 1036934 (2022). Zhang, L. et al. AI-boosted CRISPR-Cas13a and total internal reflection fluorescence microscopy system for SARS-CoV-2 detection. 3, 1015223 (2022). Qi, J., Ma, L., Cui, Z., Yu, Y. J. C. & Systems, I. Computer vision-based hand gesture recognition for human-robot interaction: a review. 1–26 (2023). Kim, J., Mastnik, S. & André, E. in Proceedings of the 13th international conference on Intelligent user interfaces. 30–39. Additional Declarations The authors declare no competing interests. Supplementary Files manusriptsupplementary.docx SI information SupplementaryTables.docx Cite Share Download PDF Status: Posted Version 1 posted You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-3892812","acceptedTermsAndConditions":true,"allowDirectSubmit":true,"archivedVersions":[],"articleType":"Research Article","associatedPublications":[],"authors":[{"id":268937107,"identity":"6a320396-f76a-4bea-9391-0b358d92f33a","order_by":0,"name":"Likun Zhang","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Likun","middleName":"","lastName":"Zhang","suffix":""},{"id":268937108,"identity":"b33d3b09-4639-4694-a18d-262fa4aaa4e2","order_by":1,"name":"Zhenglin Chen","email":"data:image/png;base64,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","orcid":"","institution":"Tsinghua university","correspondingAuthor":true,"submittingAuthor":false,"prefix":"","firstName":"Zhenglin","middleName":"","lastName":"Chen","suffix":""},{"id":268937109,"identity":"ff7b1054-5e4f-4241-96b4-9f3a564f950a","order_by":2,"name":"Huazhang Ying","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Huazhang","middleName":"","lastName":"Ying","suffix":""},{"id":268937110,"identity":"16047b4d-8ace-47f0-a693-9a86c3139588","order_by":3,"name":"Zhicheng Du","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Zhicheng","middleName":"","lastName":"Du","suffix":""},{"id":268937111,"identity":"4ba0a919-89ab-4b18-ba45-959e7117832a","order_by":4,"name":"Ziwu Song","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Ziwu","middleName":"","lastName":"Song","suffix":""},{"id":268937112,"identity":"cccfc829-caec-4e62-9cbe-46414b2baad8","order_by":5,"name":"Jiaju Chen","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Jiaju","middleName":"","lastName":"Chen","suffix":""},{"id":268937113,"identity":"e43aed0e-5f1e-4e02-8545-56b1b643c26a","order_by":6,"name":"Xi Yuan","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Xi","middleName":"","lastName":"Yuan","suffix":""},{"id":268937114,"identity":"5de9c199-4a31-4413-91b9-2b84cd0b332f","order_by":7,"name":"Canhui Yang","email":"","orcid":"","institution":"Southern University of Science and Technology","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Canhui","middleName":"","lastName":"Yang","suffix":""},{"id":268937115,"identity":"815636b9-897a-4463-8fff-ebf09bc002a4","order_by":8,"name":"Vijay Pandey","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Vijay","middleName":"","lastName":"Pandey","suffix":""},{"id":268937116,"identity":"bb4658bc-f36d-4115-b388-824a17c43361","order_by":9,"name":"Can Yang Zhang","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Can","middleName":"Yang","lastName":"Zhang","suffix":""},{"id":268937117,"identity":"89312dcf-c8cc-4c6e-b142-636e98b51e1a","order_by":10,"name":"Dongmei Yu","email":"","orcid":"","institution":"Shandong University","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Dongmei","middleName":"","lastName":"Yu","suffix":""},{"id":268937118,"identity":"4073361b-44ee-40c1-b626-70fadbdb9bca","order_by":11,"name":"Wenbo Ding","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Wenbo","middleName":"","lastName":"Ding","suffix":""},{"id":268937119,"identity":"c4083482-e205-4a9d-be3d-63797689a10b","order_by":12,"name":"Xinhui Xing","email":"","orcid":"","institution":"Tsinghua university","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Xinhui","middleName":"","lastName":"Xing","suffix":""},{"id":268937120,"identity":"3bc1a835-733d-4469-82ac-29c122f663e6","order_by":13,"name":"Jiansong Ji","email":"","orcid":"","institution":"The Fifth Affiliated Hospital of Wenzhou Medical University","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Jiansong","middleName":"","lastName":"Ji","suffix":""},{"id":268937121,"identity":"80db9e88-9720-4834-9cd0-9f5b73dbe12e","order_by":14,"name":"Chenggang Yan","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAqElEQVRIiWNgGAWjYHACxscMbCA6gXgtzMYka2GTJk2L/IzkbdUFZYcZ+NlzDBh+7iBCi8GNtLLbM84dZpDseWPA2HuGGC0SOWa3edsOA/XmGDAzthHlsByzYpAWe6K1MNzIMWMG2yJBrBaDM8+KpXnOpfNInHlWcLCXKIe1J2/8zFNmLccPZDz4SZTDBBIMQBQPiDhAjAYGBv4DBsQpHAWjYBSMgpELAMStMXi81d67AAAAAElFTkSuQmCC","orcid":"","institution":"Hangzhou Dianzi University","correspondingAuthor":true,"submittingAuthor":false,"prefix":"","firstName":"Chenggang","middleName":"","lastName":"Yan","suffix":""},{"id":268937122,"identity":"66700159-8d31-4c6f-967c-b9acae557093","order_by":15,"name":"Peiwu Qin","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAA+klEQVRIiWNgGAWjYJCCAwwVMAYIAYEEYS1ngCQbKVoYGNsgWhiI0mIukbzxcOG8OnsG+faHhwt+3Unsb2A+eJuHwS4PlxbLGWkFh2duO8zMwMZjcHhm37PEGQfYkq15GJKLcWkxuJ1jcJh32wE2oBaGw7w9hxMbDvCYSfMwHEhswKtlTh0PAxv7A7CW+Qf4vxGhpYFZAuh9g8M8Pw4nbjjAw4ZXi+X8ZwWHeY4dNmBjA+s9bLzxMJux5RyDZJxazHkOb/7MU1Nnz898/PFnnj+HZecdb354402FHW6HgREDNFrAEcQMFccFDFBl/+BWOQpGwSgYBSMXAADIn1m98xx0BgAAAABJRU5ErkJggg==","orcid":"","institution":"Tsinghua university","correspondingAuthor":true,"submittingAuthor":false,"prefix":"","firstName":"Peiwu","middleName":"","lastName":"Qin","suffix":""}],"badges":[],"createdAt":"2024-01-24 04:00:54","currentVersionCode":1,"declarations":{"humanSubjects":true,"vertebrateSubjects":false,"conflictsOfInterestStatement":false,"humanSubjectEthicalGuidelines":true,"humanSubjectConsent":true,"humanSubjectClinicalTrial":false,"humanSubjectCaseReport":false,"vertebrateSubjectEthicalGuidelines":false,"coiExplicitlySet":false},"doi":"10.21203/rs.3.rs-3892812/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-3892812/v1","draftVersion":[],"editorialEvents":[],"editorialNote":"","failedWorkflow":false,"files":[{"id":50174813,"identity":"7d83ae24-ed82-4964-aa4f-96dad654e96c","added_by":"auto","created_at":"2024-01-25 16:15:00","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":547879,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cstrong\u003eSchematic illustration for the preparation and application of CEAB films. a \u003c/strong\u003eChemical structure of ChCl, EG, AA, zwitterions, and photoinitiator.\u003cstrong\u003e b\u003c/strong\u003e Fabrication of the CEAB films: firstly, prepare the precursors; secondly, cast the precursor between the PET films and maintain pressure exertion; thirdly, polymerize the precursor. \u003cstrong\u003ec \u003c/strong\u003eSchematic structure of CEAB elastomer. \u003cstrong\u003ed\u003c/strong\u003e CEAB gel for epidermal biopotentials’ detection and application.\u003c/p\u003e","description":"","filename":"1.png","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/fc5a2336195793ea7b3e955f.png"},{"id":50175647,"identity":"0dcf1963-b633-41fa-9fea-799d5c6674b1","added_by":"auto","created_at":"2024-01-25 16:23:00","extension":"png","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":564981,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cstrong\u003eCEAB fabrication and characterization.\u003c/strong\u003e \u003cstrong\u003ea \u003c/strong\u003eThe relationship between thickness and pressure of CEAB film\u003cstrong\u003e. \u003c/strong\u003eCEAB film morphology characterized by\u003cstrong\u003eb \u003c/strong\u003eSEM (scale bar 1 μm) and\u003cstrong\u003e c \u003c/strong\u003eAFM (scale bar 4 μm). \u003cstrong\u003ed\u003c/strong\u003e Transmittance of CEAB film and photographs of logo covered by 200 μm thick CEAB films (inset). \u003cstrong\u003ee\u003c/strong\u003e ATR-FTIR of individual components and CEAB film. \u003cstrong\u003ef\u003c/strong\u003e TGA curve of CEAB film. \u003cstrong\u003eg\u003c/strong\u003e DSC curve of CEAB film. \u003cstrong\u003eh\u003c/strong\u003e Weight changes of CEAB and commercial hydrogel at 10%, 60% RH within 7 days. \u003cstrong\u003ei\u003c/strong\u003eDemonstration of the electrical property of CEAB film: Nyquist plots at temperatures from -25 ~ 60 ℃.\u003c/p\u003e","description":"","filename":"2.png","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/4eb85514f228a017c8257519.png"},{"id":50175646,"identity":"cf1e3c04-d49f-4738-abcd-bb2682b64813","added_by":"auto","created_at":"2024-01-25 16:23:00","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":652725,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cstrong\u003eMechanical properties and self-healing ability of CEAB films. a \u003c/strong\u003eRepresentative true tension stress-strain curves of CEAB films with variable thicknesses. \u003cstrong\u003eb \u003c/strong\u003eThe bright-field microscope images of a 2 mm thick CEAB film obtained at self-healing intervals of 0, 10 mins, and 8 h. \u003cstrong\u003ec \u003c/strong\u003eRepresentative curves of the peeling force per width (F/W) versus displacement with variable thicknesses of the CEAB films.\u003cstrong\u003e d \u003c/strong\u003eThe representative curve of the shear strength versus displacement of a 500 μm thick CEAB film. \u003cstrong\u003ee \u003c/strong\u003eA snapshot of the moment when the 500 μm thick CEAB film is peeled off from the dorsal hand.\u003c/p\u003e","description":"","filename":"3.png","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/df950b6d7bc730f76fd57c71.png"},{"id":50174819,"identity":"a45cb42b-30ac-4d1e-96aa-32e199aa89f2","added_by":"auto","created_at":"2024-01-25 16:15:00","extension":"png","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":2420368,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cstrong\u003eConformability and Biocompatibility of CEAB films. a\u003c/strong\u003e The conformability of CEAB films with different thicknesses on the skin: The structure of a human hand (left) and optical images (right) depicting the surface texture of the bare replica and the replica covered by 3.55 µm, 200 µm CEAB film, respectively. \u003cstrong\u003eb \u003c/strong\u003eThe SEM image of the replica covered by 3.55 µm, and 200 µm CEAB film, respectively. \u003cstrong\u003ec \u003c/strong\u003eCCK-8 results and \u003cstrong\u003ed\u003c/strong\u003emicroscope images of 3T3 cells cultured with regular medium or regular medium plus CEAB extracts at 12 h and 24 h, respectively. \u003cstrong\u003ee \u003c/strong\u003eThe comparison of water vapor transmission rate for a 200 µm thick CEAB film, a 50 µm thick PDMS, and a 4 µm thick PET film at RH 40% for 5 d.\u003c/p\u003e","description":"","filename":"4.png","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/e86f84811e668f6231a14c55.png"},{"id":50174820,"identity":"afa28ce4-e8cb-49d6-8829-916041ad5df9","added_by":"auto","created_at":"2024-01-25 16:15:00","extension":"png","order_by":5,"title":"Figure 5","display":"","copyAsset":false,"role":"figure","size":618221,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cstrong\u003eBiopotentials acquisition based on CEAB electrodes and signals quality evaluation.\u003c/strong\u003e \u003cstrong\u003ea\u003c/strong\u003e ECG measured by Ag/AgCl (black) gel, CEAB electrode (red) without and with vibration. Rhythmics-relevant P, Q, R, S, and T waves are identified, even when vibration is exerted near the CEAB electrode. \u003cstrong\u003eb \u003c/strong\u003eThe SNR of the ECG signal collected by Ag/AgCl (purple) gel, and CEAB (blue) electrode at static and vibration state, respectively. \u003cstrong\u003ec \u003c/strong\u003eThe EMG\u003cstrong\u003e \u003c/strong\u003eSNR (full lines) and noise RMS (dotted lines) of Ag/AgCl (black) gel, CEAB electrode (red). \u003cstrong\u003ed\u003c/strong\u003e The EMG signals recorded using Ag/AgCl (black) gel and CEAB electrode (red) during grip force exertions of 50 N, 320 N, and 650 N, respectively. \u003cstrong\u003ee \u003c/strong\u003eThe facial EMG signals recorded by Ag/AgCl (black) gel and CEAB electrode (red) during smiling episodes. \u003cstrong\u003ef \u003c/strong\u003eThe original EEG signals recorded by CEAB electrode while \u003cstrong\u003eg\u003c/strong\u003e the β band EEG signals obtained through FFT of the original EEG signals, recorded during the volunteer's engagement in exercise, calmness, and sleep.\u003c/p\u003e","description":"","filename":"5.png","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/f5944de03e58e16892e18061.png"},{"id":50176110,"identity":"a950d6cc-069b-490d-a107-93b770866554","added_by":"auto","created_at":"2024-01-25 16:31:00","extension":"png","order_by":6,"title":"Figure 6","display":"","copyAsset":false,"role":"figure","size":525929,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cstrong\u003eClinical detection and depression detection based on CEAB electrodes. a\u003c/strong\u003e The knee jerk reflex EMG signals collected by CEAB electrodes during 4 hammer taps. \u003cstrong\u003eb \u003c/strong\u003eThe thigh muscles' EMG signals are collected by CEAB electrodes during leg voluntary contraction. \u003cstrong\u003ec \u003c/strong\u003eThe EEG signal preprocesses and sample segmentation. \u003cstrong\u003ed\u003c/strong\u003e Eight frequency bands are acquired after FFT and eSense values are extracted. \u003cstrong\u003ee \u003c/strong\u003eThe 16 features are extracted, with 14 linear and 2 non-linear included. \u003cstrong\u003ef \u003c/strong\u003eThe feature data are fed into machine learning models for training and classification. \u003cstrong\u003eg \u003c/strong\u003eConfusion matrix of depression prediction by RF model on test sets, with true categories along the row and predicted types along the column.\u003c/p\u003e","description":"","filename":"6.png","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/50ac741859331822d3420340.png"},{"id":50174816,"identity":"344952cb-206d-453d-b481-27839f4bdd78","added_by":"auto","created_at":"2024-01-25 16:15:00","extension":"png","order_by":7,"title":"Figure 7","display":"","copyAsset":false,"role":"figure","size":1035342,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cstrong\u003eGesture recognition and gesture replication by robotic hands. a \u003c/strong\u003eArchitecture of the gesture-recognition CNN model. \u003cstrong\u003eb \u003c/strong\u003eConfusion matrix of gesture recognition, with actual gesture type along the rows and predicted gesture type along the columns.\u003cstrong\u003e \u003c/strong\u003eBy combining the signal acquisition with CEAB electrodes and data analysis with the CNN model, the EMG biopotentials can instruct the robotic arm to perform the gesture of \u003cstrong\u003ec \u003c/strong\u003eyeah\u003cstrong\u003e d \u003c/strong\u003efist\u003cstrong\u003e e \u003c/strong\u003eok.\u003c/p\u003e","description":"","filename":"7.png","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/b9c35862613ce1d37c6c611b.png"},{"id":50176315,"identity":"f0cd24c5-ff90-4d9c-ab2f-7c1652f2a181","added_by":"auto","created_at":"2024-01-25 16:39:02","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":5950228,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/08e58d39-9db8-4449-94c1-102ff49ea736.pdf"},{"id":50174818,"identity":"064ce4e4-0d85-48ff-a16a-1c0ba92ad0f1","added_by":"auto","created_at":"2024-01-25 16:15:00","extension":"docx","order_by":1,"title":"","display":"","copyAsset":false,"role":"supplement","size":4938243,"visible":true,"origin":"","legend":"\u003cp\u003eSI information\u003c/p\u003e","description":"","filename":"manusriptsupplementary.docx","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/02bab0e1691ccc50b01fb67b.docx"},{"id":50174812,"identity":"bbfd1581-6c15-45b1-9919-306a79b895e4","added_by":"auto","created_at":"2024-01-25 16:15:00","extension":"docx","order_by":2,"title":"","display":"","copyAsset":false,"role":"supplement","size":16793,"visible":true,"origin":"","legend":"\u003cp\u003e\u003cbr\u003e\u003c/p\u003e","description":"","filename":"SupplementaryTables.docx","url":"https://assets-eu.researchsquare.com/files/rs-3892812/v1/84de756aab736becafcaf951.docx"}],"financialInterests":"The authors declare no competing interests.","formattedTitle":"\u003cp\u003eA 3.55-μm ultrathin, skin-like mechanoresponsive, compliant, and seamless ionic conductive electrode for epidermal electrophysiological signal acquisition and human-machine-interaction\u003c/p\u003e","fulltext":[{"header":"Introduction","content":"\u003cp\u003eFlexible ionic conductive electrodes play a pivotal role in skin-surface electronic devices by facilitating electrical signal transmission\u003csup\u003e\u003cspan additionalcitationids=\"CR2 CR3\" citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e\u003c/sup\u003e. They are indispensable for tasks such as continuous, non-invasive health monitoring\u003csup\u003e\u003cspan additionalcitationids=\"CR6\" citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e\u003c/sup\u003e and swift, efficient human-computer interactions\u003csup\u003e\u003cspan additionalcitationids=\"CR9\" citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR10\" class=\"CitationRef\"\u003e10\u003c/span\u003e\u003c/sup\u003e. For effective long-term acquisition of electrophysiological signals from the skin surface, electrode materials must possess specific attributes: adhesion\u003csup\u003e\u003cspan additionalcitationids=\"CR12\" citationid=\"CR11\" class=\"CitationRef\"\u003e11\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e\u003c/sup\u003e, stretchability\u003csup\u003e\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e,\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e\u003c/sup\u003e, Young's modulus similar to skin\u003csup\u003e\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e,\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e\u003c/sup\u003e, excellent conductivity\u003csup\u003e\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e,\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e\u003c/sup\u003e, and self-healing\u003csup\u003e\u003cspan additionalcitationids=\"CR19 CR20\" citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e\u003c/sup\u003e after external damage. Two types of skin electrodes: metal dry electrodes\u003csup\u003e\u003cspan additionalcitationids=\"CR23 CR24 CR25 CR26\" citationid=\"CR22\" class=\"CitationRef\"\u003e22\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e\u003c/sup\u003e and hydrogel wet electrodes\u003csup\u003e\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e,\u003cspan citationid=\"CR29\" class=\"CitationRef\"\u003e29\u003c/span\u003e\u003c/sup\u003e, are available on the market. While metal dry electrodes have stable physical and chemical characteristics, their limited stretchability and adhesive capabilities can cause signal distortions due to human movement\u003csup\u003e\u003cspan additionalcitationids=\"CR31\" citationid=\"CR30\" class=\"CitationRef\"\u003e30\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e\u003c/sup\u003e. In contrast, hydrogel electrodes excel in biocompatibility\u003csup\u003e\u003cspan citationid=\"CR33\" class=\"CitationRef\"\u003e33\u003c/span\u003e,\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e\u003c/sup\u003e, conductivity, and skin conformity\u003csup\u003e\u003cspan citationid=\"CR35\" class=\"CitationRef\"\u003e35\u003c/span\u003e\u003c/sup\u003e. Yet, they lose water over time\u003csup\u003e\u003cspan citationid=\"CR36\" class=\"CitationRef\"\u003e36\u003c/span\u003e\u003c/sup\u003e, diminishing their conductivity, stretchability, and softness; especially freezing at low temperatures and dehydration at high temperatures can compromise signal acquisition\u003csup\u003e\u003cspan citationid=\"CR37\" class=\"CitationRef\"\u003e37\u003c/span\u003e,\u003cspan citationid=\"CR38\" class=\"CitationRef\"\u003e38\u003c/span\u003e\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eDeep eutectic solvents (DESs) are promising, safe, and stable alternatives to conventional soft ionic conductors\u003csup\u003e\u003cspan citationid=\"CR39\" class=\"CitationRef\"\u003e39\u003c/span\u003e,\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e\u003c/sup\u003e. Comprising hydrogen bond donors (e.g., ethylene glycol, EG) and acceptors (e.g., choline chloride, ChCl)\u003csup\u003e\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e,\u003cspan citationid=\"CR41\" class=\"CitationRef\"\u003e41\u003c/span\u003e\u003c/sup\u003e, these solvents are water-free, have low vapor pressure, and exhibit strong conductivity and biocompatibility\u003csup\u003e\u003cspan citationid=\"CR42\" class=\"CitationRef\"\u003e42\u003c/span\u003e,\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e\u003c/sup\u003e. The composite advantages of DESs have spurred rapid development in ionic conductors\u003csup\u003e\u003cspan citationid=\"CR44\" class=\"CitationRef\"\u003e44\u003c/span\u003e,\u003cspan citationid=\"CR45\" class=\"CitationRef\"\u003e45\u003c/span\u003e\u003c/sup\u003e. Li et al combined acrylic acid (AA) with DESs to prepare the DES gel with stretchability (\u0026gt;\u0026thinsp;1000%), high conductivity (1.26 mS\u0026#158;cm\u003csup\u003e\u0026minus;\u0026thinsp;1\u003c/sup\u003e), and high adhesion to the skin (~\u0026thinsp;100 N\u0026#158;m\u003csup\u003e\u0026minus;\u0026thinsp;1\u003c/sup\u003e)\u003csup\u003e46\u003c/sup\u003e. Despite these advancements, creating a DES gel with both self-healing and skin-like mechanical properties remains a challenge. Human skin is self-repairable, restoring both its mechanical and electrical functionalities\u003csup\u003e\u003cspan citationid=\"CR47\" class=\"CitationRef\"\u003e47\u003c/span\u003e\u003c/sup\u003e. Distinctively, human skin exhibits a nonlinear stress-strain relationship, resembling the shape of J\u003csup\u003e\u003cspan additionalcitationids=\"CR49\" citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e\u003c/sup\u003e. While it feels soft upon touch, and swiftly stiffens under high strains to prevent damage. Inspired by skin\u0026rsquo;s mechanic properties, a hybrid network that blends weakly complex zwitterions with robust hydrogen bond interactions can emulate skin's softness while rapidly stiffening under strain, mimicking its protective mechanism.\u003c/p\u003e \u003cp\u003eIn this study, we develop an ionic, conductive, compliant, dry, adhesive, and self-healing electrode for epidermal electrophysiology monitoring, depression detection, and human-machine interaction. We use ChCl and EG as the deep eutectic solvent (DES), betaine as the zwitterionic network and crosslinker, and AA to form the conductive framework. This novel CEAB electrode surpasses traditional Ag/AgCl gel electrodes in epidermal biopotential monitoring. It ensures improved conductivity across a wide temperature range, offers gentle conformability to the skin, and significantly reduces noise levels during dynamic detections. we can use the CEAB electrodes to capture high-quality epidermal biopotential signals consistently, such as electrocardiogram (ECG), electromyogram (EMG), and electroencephalogram (EEG)\u003csup\u003e\u003cspan citationid=\"CR51\" class=\"CitationRef\"\u003e51\u003c/span\u003e\u003c/sup\u003e, even amidst movement. Furthermore, we develop a machine-learning algorithm that effectively identifies abnormal EEG patterns in patients with depression. Meanwhile, by integrating this electrode with shallow CNN (Convolution Neural Network) algorithm, we demonstrate prosthetic limb control as gesture replication based on EMG signals. A comparison of CEAB electrodes to representative electrodes for biopotential applications is shown in Supplementary Table\u0026nbsp;1.\u003c/p\u003e"},{"header":"Results","content":"\u003cp\u003eFabrication and characterization of CEAB\u003c/p\u003e \u003cp\u003eWe first develop a method to prepare CEAB film with controlled thickness and scalability, based on the pressure exertion. The fabrication process of the electrode is illustrated in Fig.\u0026nbsp;\u003cspan refid=\"Fig1\" class=\"InternalRef\"\u003e1\u003c/span\u003eb (Further setup details in Supplementary Fig. S1a). Firstly, the DES is synthesized by mixing ChCl and EG stirred at 80 ℃ for 20 mins. Then monomer AA is dissolved in DES to form a clear solution\u003csup\u003e\u003cspan citationid=\"CR46\" class=\"CitationRef\"\u003e46\u003c/span\u003e\u003c/sup\u003e. After that, the betaine as zwitterion, and Irgacure 2959 as the photoinitiator are dissolved in the solution to prepare the CEAB precursor. The precursor solution consists of ChCl, EG, AA, and betaine in a molar ratio of 2:4:4:1, and the weight percentage of Irgacure 2959 is 0.1% (Fig.\u0026nbsp;\u003cspan refid=\"Fig1\" class=\"InternalRef\"\u003e1\u003c/span\u003ea). The transparent precursor (Supplementary Fig. S1b) is then cast between two pieces of Polyethylene terephthalate (PET) supporting films, covered by a flat glass mold, different forces are exerted on the surface to generate precursor layer with different thickness. Upon polymerization of the precursor using UV light (365 nm, 10 W power, 5 min), the resulting CEAB gel serves as an adhesive and stretchable dry electrode for capturing epidermal biopotentials such as ECG, EMG, and EEG (Fig.\u0026nbsp;\u003cspan refid=\"Fig1\" class=\"InternalRef\"\u003e1\u003c/span\u003ed).\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eThe thickness of the CEAB film is influenced primarily by two main factors: the magnitude and duration of pressure. Ensuring proper duration of pressure facilitates precursor diffusion between the PET films, subsequently impacting the film's thickness post-photopolymerization. Precursor diffusion largely completes within 5 minutes under free load, as evidenced in Supplementary Movie 1. Therefore, we set the pressure duration to 5 minutes. Figure\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ea demonstrates that the CEAB film's thickness can be varied via the applied forces on the glass surface. Specifically, when controlling the pressure from 4109 to 0 Pa, the thickness is changed from 3.55 \u0026micro;m to approximately 46.9 \u0026micro;m. For films with a thickness surpassing 50 \u0026micro;m, we employ a molding strategy. This involves placing a spacer with a specific thickness between two glass plates and PET support films, followed by film removal post-curing. We coat the PET film's surface with silicone oil to ease the CEAB film's separation, a critical step for maintaining the structural integrity of sub-5\u0026micro;m freestanding samples\u003csup\u003e\u003cspan citationid=\"CR52\" class=\"CitationRef\"\u003e52\u003c/span\u003e\u003c/sup\u003e. Scanning electron microscope (SEM) and atomic force microscope (AFM) (Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003eb and \u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ec) both show the freestanding CEAB film's smooth morphology, indicating considerable macro-scale homogeneity. Moreover, the AFM height image reveals that the CEAB film's surface roughness remains below 10 nm (Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ec and Supplementary Fig.S2). In comparison to traditional techniques, our pressure-diffusion approach can provide a broad film thickness control range and extensive surface homogeneity. Supplementary Fig. S3 further illustrates the self-adhesion of a 200 \u0026micro;m thick CEAB film on the palm, showcasing its capability to replicate complex, curved surfaces over large areas.\u003c/p\u003e \u003cp\u003eThe 200 \u0026micro;m CEAB film demonstrates an impressive optical transmittance exceeding 95% between 400\u0026ndash;800 nm wavelengths (Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ed). This exceptional transmittance results from macroscopic averaging of compositional and structural factors. Furthermore, a QR code enveloped by this CEAB film remains effortlessly scannable, as depicted in the inset of Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ed. Utilizing Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR) spectroscopy, we delineate the characteristic peaks of the CEAB film and discern their interactions (Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ee). CEAB film and EG show OH peak at 3307 cm\u003csup\u003e\u0026minus;\u0026thinsp;1\u003c/sup\u003e and 3297 cm\u003csup\u003e\u0026minus;\u0026thinsp;1\u003c/sup\u003e, this redshift of OH group indicates the hydrogen bond formation\u003csup\u003e\u003cspan citationid=\"CR53\" class=\"CitationRef\"\u003e53\u003c/span\u003e\u003c/sup\u003e, which is a characteristic of DES. For CEAB, both the ν(C\u0026thinsp;=\u0026thinsp;O) of AA and betaine shift to higher wavenumbers, while ν(C-N) of betaine shift to lower wavenumbers, suggesting the formation of [N(CH\u003csub\u003e3\u003c/sub\u003e)\u003csub\u003e3\u003c/sub\u003e]\u003csup\u003e+\u003c/sup\u003e:[COO\u003csup\u003e\u0026minus;\u003c/sup\u003e] ion pairs\u003csup\u003e\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e,\u003cspan citationid=\"CR54\" class=\"CitationRef\"\u003e54\u003c/span\u003e\u003c/sup\u003e. Additionally, thermogravimetric analysis (TGA; Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ef) confirms the film's exceptional temperature stability, with minimal weight loss (\u0026lt;\u0026thinsp;5%) until 82.5\u0026deg;C, and a decomposition temperature nearing 240\u0026deg;C, suitable for high demanding conditions. Concurrently, differential scanning calorimetry (DSC) in Fig.\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003eg establishes that the CEAB's glass transition temperature (Tg) remains below \u0026minus;\u0026thinsp;60\u0026deg;C, underscoring its flexibility even at low temperatures. Supplementary Fig. S4 further demonstrates the flexibility of 2 mm thick CEAB film that it can be easily twisted at both 25 ℃ and \u0026minus;\u0026thinsp;30 ℃. Figure\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003eh reveals that, in contrast to Ag/AgCl hydrogel, the CEAB gel exhibits a weight increase of approximately 15% at 60% relative humidity (RH) and experiences minimal weight loss (below 5%) at 10% RH over 7 days. This result underscores the CEAB film's potential for effective epidermal moisture retention. Figure\u0026nbsp;\u003cspan refid=\"Fig2\" class=\"InternalRef\"\u003e2\u003c/span\u003ei details the temperature-dependent ionic conductivity within a range of -50 to 60\u0026deg;C. To determine the electrical conductivity (σ) of CEAB film, the formula σ\u0026thinsp;=\u0026thinsp;d/RS is employed, where d represents the gel thickness, S signifies the gel area, and R denotes the value where the plot intersects the Z' axis. As temperature ascends, CEAB exhibits enhanced conductivity; for instance, its conductivity registers as 1.69 \u0026times; 10\u003csup\u003e\u0026minus;\u0026thinsp;2\u003c/sup\u003e, 1.33, and 8.18 mS\u0026middot;cm\u003csup\u003e\u0026minus;\u0026thinsp;1\u003c/sup\u003e at temperatures of -25\u0026deg;C, 25\u0026deg;C, and 60\u0026deg;C respectively (Supplementary Fig. S5a). Besides, the ionic conductivity's temperature dependency follows with the Vogel\u0026thinsp;\u0026minus;\u0026thinsp;Fulcher\u0026thinsp;\u0026minus;\u0026thinsp;Tammann (VFT) relationship\u003csup\u003e\u003cspan citationid=\"CR55\" class=\"CitationRef\"\u003e55\u003c/span\u003e\u003c/sup\u003e, demonstrating a robust congruence between theory and empirical findings (Supplementary Fig. S5b). Such elevated conductivities arise from rapid proton migration within the CEAB at high temperatures, inferred from its composition. DES contains ionized components such as hydrogen donors and hydrogen acceptors, which offer more protons to increase the conductivity. In addition, the low melting point of DES contributes to the free mobility of the protons, thus providing high conductivity of CEAB.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eMechanical properties and self-healing ability\u003c/p\u003e \u003cp\u003eMechanical properties akin to the skin are pivotal for the application of epidermal electrodes, serving as a seamless interface between skin and electronics\u003csup\u003e\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e,\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e\u003c/sup\u003e. To evaluate the mechanical attributes of the CEAB film, a uniaxial tensile setup is employed. The true stress-strain curve (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e3\u003c/span\u003ea) of the CEAB film, varying in thickness, reveals strain-stiffening behaviors reminiscent of skin. This indicates the film presents a soft texture upon initial touch but swiftly stiffens, safeguarding against damage under elevated strains. Additionally, Young\u0026rsquo;s moduli of the CEAB films range from 3.23 to 59.74 kPa, aligning with values measured in the fibrous dermis (35\u0026ndash;150 kPa) and the hypodermis (2 kPa)\u003csup\u003e\u003cspan citationid=\"CR56\" class=\"CitationRef\"\u003e56\u003c/span\u003e\u003c/sup\u003e. As delineated in Supplementary Table\u0026nbsp;2, Young\u0026rsquo;s modulus increases twentyfold as the film's thickness dwindles from 500 \u0026micro;m (3.23 kPa) to 3.55 \u0026micro;m (59.74 kPa). This enhancement stems from denser cross-linking for thinner precursors under identical UV exposure durations. Impressively, the CEAB film can stretch approximately 800% (engineering strain) of its original length without exhibiting discernible mechanical failure, a capability aligning well with on-skin electronics requirements, given that skin typically endures a maximum strain of around 30%\u003csup\u003e56\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eCEAB gel demonstrates rapid self-healing attributes, which meet the requirement of an ideal epidermal electrode that self-recovers from external mechanical damage. As depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e3\u003c/span\u003eb, the scar on the CEAB film vanishes entirely within 10 minutes at room temperature, with bubbles near the scar dissipating within 8 hours (Supplementary Movie 2). This self-healing process is attributed to the electrostatic interaction in betaine, reversible H-bonds in ChCl, EG, and polyacrylic acid, facilitating polymer chain diffusion at the interfaces. To assess CEAB film's self-adhesion on porcine skin, a 90\u0026deg; peeling experiment is conducted, as illustrated in Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e3\u003c/span\u003ec. Within a thickness range from 3.55 \u0026micro;m to 500 \u0026micro;m, the CEAB exhibits a peeling interface toughness ranging between 5\u0026ndash;20 J/m\u003csup\u003e2\u003c/sup\u003e, demonstrating strong adhesive capability for artifact-resistant epidermal electrical signal collection during movement. Supplementary Fig. S6a-d further verifies the strong adhesion to plastic tubes, paper, PET film, and rubber gloves respectively. Concurrently, the 500 \u0026micro;m CEAB film demonstrates a shear strength of 63 kPa on the porcine skin (Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e3\u003c/span\u003ed), translating to a maximal shear force of 12.60 N\u0026mdash;70 times of the 90\u0026deg; peel force (0.18N). Despite its superior adhesive qualities, the CEAB film allows for effortless and comfortable removal, as depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e3\u003c/span\u003ee. Unlike conventional tapes (3M VHB) that often induce discomfort due to excessive adhesion and residual islands, the CEAB film ensures a user-friendly detachment.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eConformability and biocompatibility\u003c/p\u003e \u003cp\u003eCEAB films demonstrate remarkable conformability across diverse rough surfaces. Two primary factors influencing a material's conformability are its Young\u0026rsquo;s modulus and thickness; a decrease in both parameters enhances the material's ability to conform to irregular surfaces\u003csup\u003e\u003cspan citationid=\"CR57\" class=\"CitationRef\"\u003e57\u003c/span\u003e\u003c/sup\u003e. Supplementary Fig. S7a-d reveal that both 50 \u0026micro;m and 200 \u0026micro;m CEAB films adhere tightly to human skin due to their ultrasoft nature, fostered by hydrogen bonding on both the electrode-skin boundary and internal electrode, as well as weak electrostatic interactions in the electrode. These CEAB films readily accommodate skin deformations, such as stretching and squeezing. In Supplementary Fig. S8a-c, a 50 \u0026micro;m CEAB film affixed to the dorsal hand synchronizes with skin movements seamlessly\u0026mdash;elongating upon stretching and forming wrinkles similar to skin creases during compression. In contrast, a 50 \u0026micro;m PET adhesive tape partially loses contact with the skin, failing to emulate the skin's subtle wrinkles due to modulus disparities between the skin and the PET film. Additionally, the 50 \u0026micro;m CEAB film exhibits conformal adhesion to fruit peels, including apples and avocados, as depicted in Supplementary Fig. S9, whereas PET tape demonstrates partial attachment from these fruit surfaces.\u003c/p\u003e \u003cp\u003eBesides, since the geometry of the glyphic patterns at hands varies at the different locations, 3.55 \u0026micro;m and 200 \u0026micro;m thick CEAB film are attached to different regions of the hand to investigate the local texture conformability, including distal phalanges, proximal phalanges, metacarpophalangeal, and palm. Silicon rubber is used as the human hand replica, and bare skin without an attached electrode is captured to demonstrate the primitive morphology. As depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003ea, with 3.55 \u0026micro;m thick CEAB film covering the surface, glyphic lines on proximal phalanges and metacarpophalangeal, including primary, secondary, tertiary, and even quaternary lines can be distinguished under the optical microscope. Additionally, the 3.55 \u0026micro;m thick CEAB film precisely conforms to the ridges and valleys, revealing fine structures including dense and directionally varying grooves, as well as irregular elevations between furrows with high resolution. The intimate contact between the fingerprint replica and 3.55 \u0026micro;m CEAB film is further investigated using SEM (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003eb), which reveals a secure adherence of the 3.55 \u0026micro;m CEAB film to the fingerprint replica, indicating distinct ridges and valleys with no detectable formation of air gaps. However, as the thickness of the CEAB film increases to 200 \u0026micro;m, the ability to discern fine structures such as grooves and papules is restricted due to a size mismatch; specifically, the depth between ridges and valleys is typically less than 60 \u0026micro;m\u003csup\u003e\u003cspan citationid=\"CR58\" class=\"CitationRef\"\u003e58\u003c/span\u003e\u003c/sup\u003e. Nonetheless, covered by the 200 \u0026micro;m CEAB film, the ridges, and valleys on the distal phalanges and palm remain discernible due to their ultrasoft mechanical properties. In agreement with optical images, ridges, and valleys can be discerned on the metacarpophalangeal replica covered by 200 \u0026micro;m CEAB film, with no observable air gaps due to the ultrasoft mechanical properties.\u003c/p\u003e \u003cp\u003eThe cytotoxicity assay with NIH3T3 cells proves the biocompatibility of CEAB gel that is suitable for on-skin applications (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003ec). As depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003ed, for both the control group and the CEAB-conditioned group, NIH3T3 fibroblasts exhibit a flattened morphology after 12-hour incubation, followed by the development of fine cytoplasmic extensions after 24 hours of incubation. The water vapor transmission ability of CEAB film is compared with common interactive materials for human-machine interface substrates, such as PDMS and Parylene. After 5 days, CEAB had nearly 50% water vapor transmission, while PDMS and PET only had 10% or less water vapor transmission (Fig.\u0026nbsp;\u003cspan refid=\"Fig4\" class=\"InternalRef\"\u003e4\u003c/span\u003ee). This indicates that CEAB film, as a wearable electrode material, will not block the skin surface and affect skin respiration. We summarize the overall comparison of our CEAB film with the most representative ionic gels in Supplementary Table\u0026nbsp;3.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eElectrode/skin contact impedance and epidermal biopotential detection\u003c/p\u003e \u003cp\u003eThe electrode/skin contact impedance within 1 h of the CEAB electrode is measured in the frequency range of 1-10\u003csup\u003e4\u003c/sup\u003e Hz. The CEAB electrode shows stable electrode/skin contact impedance (Supplementary Fig. S10a). The average electrode/skin impedance with 1 h of CEAB electrode is much lower than the commercial Ag/AgCl gel electrode, i.e., 284.259 kΩ, 1873.981 kΩ for the former and 337.698 kΩ, 2450.774 kΩ for the latter at 100 Hz and 10 Hz, respectively (Supplementary Fig. S10b). Stable and lower electrode/skin contact impedance contributes to high-quality biopotential acquisition. The wearable 200 \u0026micro;m CEAB electrodes are employed to investigate epidermal ECG, EMG, and EEG. Figure\u0026nbsp;\u003cspan refid=\"Fig1\" class=\"InternalRef\"\u003e1\u003c/span\u003ed illustrates two CEAB electrodes attached to a volunteer's chest for ECG signal recording. Notably, rhythm-related parameters\u0026mdash;including P, Q, R, S, and T waves\u0026mdash;are distinctly identifiable in both static and dynamic states, crucial for clinical diagnoses\u003csup\u003e\u003cspan citationid=\"CR59\" class=\"CitationRef\"\u003e59\u003c/span\u003e\u003c/sup\u003e, as shown in Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003ea. In contrast, the Ag/AgCl gel electrode exhibits higher noise levels and unstable peaks during motion. Benefitting from its robust adhesion and conformability, the CEAB electrode has superior signal-to-noise ratios (SNR) of 32.7 dB and 29.9 dB in static and dynamic states, respectively, surpassing the 28.0 dB and 18.8 dB of the Ag/AgCl gel electrode, as depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003eb. This performance underscores the CEAB electrode's resilience against motion artifacts.\u003c/p\u003e \u003cp\u003eAdditionally, to capture muscle biopotentials, two CEAB electrodes are affixed to the forearm as working electrodes, while one is placed on the elbow as a reference electrode. By sustaining a grip force of 50 N, we assess the SNR and noise level of CEAB electrodes during EMG signal acquisition. Figure\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003ec illustrates the noise analysis using RMS (root mean square) on baseline signals acquired during rest periods. The average noise level of the CEAB electrode (21.7 \u0026micro;V) is reduced by 33.6% over the 3.5 h monitoring period compared to the Ag/AgCl gel electrode (32.7 \u0026micro;V). Furthermore, the CEAB electrodes consistently outperform Ag/AgCl gel electrodes in SNR, averaging 12.5 dB\u0026mdash;a 48.9% improvement over the 18.7 dB of the Ag/AgCl gel electrodes. This evidence solidifies that CEAB electrodes offer superior noise reduction and enhanced SNR compared to commercially available Ag/AgCl gel electrodes. Subsequent tests involving varied grip forces of 50 N, 320 N, and 650 N confirm that EMG signals remain distinguishable, aligning with the Ag/AgCl gel electrodes (Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003ed). Notably, the CEAB electrode captures more stable EMG signals with minimal baseline fluctuations, demonstrating superior reliability. Supplementary Fig. S11 further illustrates that CEAB electrodes effectively differentiate EMG signals across various hand gestures, essential for human-machine interface applications. Coincidently, Supplementary Movie 3 further demonstrates the EMG signals of the forearm during various single-finger and hand movements.\u003c/p\u003e \u003cp\u003eThe facial muscles typically exhibit non-uniform distribution, and facial skin is prone to wrinkles development with facial expressions, undergoing substantial deformation\u003csup\u003e\u003cspan citationid=\"CR60\" class=\"CitationRef\"\u003e60\u003c/span\u003e\u003c/sup\u003e. Acquiring stable and high-quality facial EMG signals using flexible electrodes with excellent conformality remains a significant challenge. To ascertain the efficacy of CEAB electrodes as proficient facial EMG electrodes, we collect facial EMG data during volunteers' smiling episodes, with Ag/AgCl gel electrodes serving as a reference. As illustrated in Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003ee, both electrodes demonstrate the capability to capture signals of good quality during volunteer smiles. However, the CEAB electrodes exhibit lower baseline noise. Throughout the entire data-acquisition process, the signals acquired by the CEAB electrodes have consistent baseline noise levels. In contrast, with an increasing time of smiles, substantial noise emerges between adjacent peaks for the Ag/AgCl gel electrode after 4 seconds. This occurrence can be attributed to the wrinkles induced by smiling, leading to motion artifacts between the Ag/AgCl gel electrode and the skin surface. The superior stretching ability and Young's modulus comparable to that of the skin of CEAB film facilitate accurate EMG signal acquisition, particularly during facial motion.\u003c/p\u003e \u003cp\u003eGiven the CEAB electrode's superior resistance to motion artifacts, minimal baseline noise, and enhanced SNR compared to Ag/AgCl gel electrodes, we utilize it for long-term EEG recordings on a volunteer, spanning up to 12 hours. Throughout this long duration, the volunteer is engaged in varied activities, including sleep, exercise, and relaxation. Notably, the quality of EEG signals remains consistent, even when the volunteer perspires during physical activities. Figure\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003ef illustrates three distinct EEG signals corresponding to different mental states: heightened activity during exercise and reduced activity during sleep. By employing fast-Fourier transformation (FFT), we segment the EEG brainwaves into specific frequency bands: δ (0-2.5 Hz), θ (3.5\u0026ndash;6.75 Hz), α (7.5-11.75 Hz), β (13\u0026ndash;30 Hz), and γ (31\u0026ndash;50 Hz)\u003csup\u003e\u003cspan citationid=\"CR61\" class=\"CitationRef\"\u003e61\u003c/span\u003e\u003c/sup\u003e. The β waves, are associated with increased energy levels and can reflect the degree of mental concentration and physical involvement\u003csup\u003e\u003cspan citationid=\"CR62\" class=\"CitationRef\"\u003e62\u003c/span\u003e,\u003cspan citationid=\"CR63\" class=\"CitationRef\"\u003e63\u003c/span\u003e\u003c/sup\u003e. Then we extract the β wave from the signal and compare the discrepancy. As depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e5\u003c/span\u003eg, the intensity of β wave during exercise state is much stronger than that at rest or sleep status, which accords with the fact that β usually increases during physical exertion.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eClinical detection and depression detection\u003c/p\u003e \u003cp\u003eThe knee jerk reflex is classified as a monosynaptic stretch reflex. In clinical settings\u003csup\u003e\u003cspan citationid=\"CR64\" class=\"CitationRef\"\u003e64\u003c/span\u003e\u003c/sup\u003e, tendon reflex examinations are commonly employed to assess the circuit integrity of the stretch reflex arc and to evaluate motor neuron functionality. To diagnose spinal pathway function, we affix CEAB electrodes to a healthy volunteer's thigh muscle. Consistent with hospital tests, when the kneecap is tapped with a small hammer, the CEAB electrodes capture a rapid surge in muscle electrophysiological activity, as depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003ea. This observation aligns with findings from clinical studies and literature. Moreover, the CEAB electrodes monitor voluntary thigh muscle contractions during leg extensions. Unlike the knee-jerk reflex, these stronger contractions manifest larger amplitudes and prolonged durations due to the engagement of multiple motor units, resulting in more pronounced motor unit action potentials, as illustrated in Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003eb.\u003c/p\u003e \u003cp\u003eDepression is a severe mental disorder characterized by persistent feelings of sadness and potential suicidal tendencies\u003csup\u003e\u003cspan citationid=\"CR65\" class=\"CitationRef\"\u003e65\u003c/span\u003e,\u003cspan citationid=\"CR66\" class=\"CitationRef\"\u003e66\u003c/span\u003e\u003c/sup\u003e. According to the World Health Organization (WHO), as of 2023, over 264\u0026nbsp;million people globally are afflicted with depression, underscoring the urgency for early diagnosis and intervention\u003csup\u003e\u003cspan citationid=\"CR67\" class=\"CitationRef\"\u003e67\u003c/span\u003e\u003c/sup\u003e. Given EEG\u0026lsquo;s ability to provide a direct reflection of brain neurological activity with high temporal resolution, EEG is increasingly recognized as a potent tool for non-invasive depression diagnosis\u003csup\u003e\u003cspan citationid=\"CR68\" class=\"CitationRef\"\u003e68\u003c/span\u003e,\u003cspan citationid=\"CR69\" class=\"CitationRef\"\u003e69\u003c/span\u003e\u003c/sup\u003e. Utilizing the CEAB electrode, we have designed a machine-learning approach to analyze single-channel EEG data of subjects at rest state, facilitating swift and reliable depression diagnosis, as depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003ec-f. Specifically, real-time data collection is conducted, followed by preprocessing with Python 3.8. EEG signals inherently display temporal variability and dynamics, and different frequency components correspond to different temporal and physiological states\u003csup\u003e\u003cspan citationid=\"CR70\" class=\"CitationRef\"\u003e70\u003c/span\u003e\u003c/sup\u003e. To build extensive training datasets for machine learning, we segment the EEG data into 2-second intervals, incorporating a 50% overlap to capture the intricate and dynamic attributes of EEG effectively (Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003ec). This windowing strategy has been demonstrated to encapsulate relevant information across varied EEG types, thereby enhancing classification outcomes\u003csup\u003e\u003cspan citationid=\"CR71\" class=\"CitationRef\"\u003e71\u003c/span\u003e\u003c/sup\u003e. Our dataset encompasses 633 samples, balanced between healthy and depression-afflicted samples. As showcased in Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003ed, we apply FFT to the original EEG signals, delineating frequency bands and deriving eSense values via NeuroSky's algorithm\u003csup\u003e\u003cspan citationid=\"CR72\" class=\"CitationRef\"\u003e72\u003c/span\u003e,\u003cspan citationid=\"CR73\" class=\"CitationRef\"\u003e73\u003c/span\u003e\u003c/sup\u003e. This algorithm can express the mental state information (attention and meditation) of the human brain with eSense values. Then we extract two distinct feature categories from the EEG data: linear attributes, including Variance, Absolute Power, Mean, and Coherence, juxtaposed against nonlinear attributes like Entropy and C0-Complexity\u003csup\u003e\u003cspan citationid=\"CR74\" class=\"CitationRef\"\u003e74\u003c/span\u003e\u003c/sup\u003e(Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003ee). Linear features contain signal specificity, whereas nonlinear attributes underscore intricacy and stability\u003csup\u003e\u003cspan citationid=\"CR74\" class=\"CitationRef\"\u003e74\u003c/span\u003e\u003c/sup\u003e. Subsequently, these features are concatenated and then input into a range of classifiers, namely Supporting Vector Machine (SVM)\u003csup\u003e\u003cspan citationid=\"CR75\" class=\"CitationRef\"\u003e75\u003c/span\u003e\u003c/sup\u003e, K-Nearest Neighbor (KNN)\u003csup\u003e\u003cspan citationid=\"CR76\" class=\"CitationRef\"\u003e76\u003c/span\u003e\u003c/sup\u003e, XGBoost\u003csup\u003e\u003cspan citationid=\"CR77\" class=\"CitationRef\"\u003e77\u003c/span\u003e\u003c/sup\u003e, and Random Forest (RF)\u003csup\u003e\u003cspan citationid=\"CR78\" class=\"CitationRef\"\u003e78\u003c/span\u003e\u003c/sup\u003e for depression detection (Fig.\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003ef). As illustrated in Table\u0026nbsp;\u003cspan refid=\"Tab1\" class=\"InternalRef\"\u003e1\u003c/span\u003e, the RF performs the best accuracy of 92.91%, recall of 92.91%, and precision of 93.19% on test dataset. Figure\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e6\u003c/span\u003eg further illustrates the confusion matrix of RF models on depression prediction.\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab1\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 1\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eMachine Learning model results.\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"5\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c5\" colnum=\"5\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e\u0026nbsp;\u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003eKNN\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003eXGBoost\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003eSVM\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c5\"\u003e \u003cp\u003eRF\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003ePrecision\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e89.78%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e89.78%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e \u003cp\u003e69.28%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c5\"\u003e \u003cp\u003e93.19%\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eRecall\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e89.76%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e89.76%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e \u003cp\u003e69.29%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c5\"\u003e \u003cp\u003e92.91%\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eF1 score\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c2\"\u003e \u003cp\u003e89.77%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c3\"\u003e \u003cp\u003e89.77%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e \u003cp\u003e69.28%\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c5\"\u003e \u003cp\u003e92.91%\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003cp\u003eTo delve deeper into understanding feature contributions for predicting depression, we employed the Gini importance method within scikit-learn for enhanced feature analysis\u003csup\u003e\u003cspan citationid=\"CR79\" class=\"CitationRef\"\u003e79\u003c/span\u003e\u003c/sup\u003e. Utilizing the RF model, individual feature importance is computed and graphically depicted in Supplementary Fig. S12. The histogram highlights four paramount features: mean attention, standard deviation σ, mean of the low γ band, and mean of the δ band (Supplementary Fig. S13a-d). Approximately 80% of individuals with depression exhibit diminished attention compared to healthy counterparts. Furthermore, ~ 20% of samples manifest higher σ, where higher variance indicates greater emotion change among subjects with depression\u003csup\u003e\u003cspan citationid=\"CR80\" class=\"CitationRef\"\u003e80\u003c/span\u003e\u003c/sup\u003e. Notably, the low γ band's sensitivity to emotional nuances indicates a trend that a majority of depression patients register elevated low γ values, thereby identifying these metrics as potential depression biomarkers\u003csup\u003e\u003cspan citationid=\"CR81\" class=\"CitationRef\"\u003e81\u003c/span\u003e,\u003cspan citationid=\"CR82\" class=\"CitationRef\"\u003e82\u003c/span\u003e\u003c/sup\u003e. Additionally, over 80% of depression samples have lower mean δ values, which is correlated to heightened psychological distress, potentially amplifying depression vulnerability\u003csup\u003e\u003cspan citationid=\"CR83\" class=\"CitationRef\"\u003e83\u003c/span\u003e\u003c/sup\u003e. Leveraging CEAB electrodes, we build a single-channel RF model finding digital depression biomarkers. EEG with CEAB electrodes offers an efficient, user-friendly, and feasible solution for depression detection via a single-channel wearable EEG headband.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eHand gesture replication by robotic hands\u003c/p\u003e \u003cp\u003eHand gestures play a pivotal role in conveying concise messages and carrying emotional implications, making them essential in both realistic and digital communication, especially within human-machine interaction applications\u003csup\u003e\u003cspan citationid=\"CR84\" class=\"CitationRef\"\u003e84\u003c/span\u003e\u003c/sup\u003e. While traditional methods of gesture sensing and recognition primarily depend on algorithms to semantically interpret images or videos\u003csup\u003e\u003cspan additionalcitationids=\"CR86 CR87\" citationid=\"CR85\" class=\"CitationRef\"\u003e85\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR88\" class=\"CitationRef\"\u003e88\u003c/span\u003e\u003c/sup\u003e, they often face challenges due to environmental interferences such as obstructed objects and varying lighting conditions\u003csup\u003e\u003cspan citationid=\"CR89\" class=\"CitationRef\"\u003e89\u003c/span\u003e\u003c/sup\u003e. Unlike traditional methods, EMG, which captures signals before muscle contraction, provides a robust solution for hand gesture recognition without interference from external environmental factors\u003csup\u003e\u003cspan citationid=\"CR90\" class=\"CitationRef\"\u003e90\u003c/span\u003e\u003c/sup\u003e. We utilize CEAB electrodes to record forearm EMG signals from volunteers performing six distinct hand gestures. The captured signals are subsequently combined with sophisticated algorithms and embedded techniques to instruct robotic arms to mimic the recorded hand movements.\u003c/p\u003e \u003cp\u003eFirstly, we collect an EMG dataset of different gestures from volunteers, encompassing categories of \"rest\", \"six\", \"eight\", \"good\", \"yeah\", \"ok\", and \"fist\". These samples are carefully segmented into intervals with 1000 data points with a 95% overlap, strategically designed to augment the dataset and encapsulate essential biopotential information related to gesture motion. Subsequently, we establish a two-layer Convolutional Neural Network (CNN) model tailored for efficient gesture classification. Figure\u0026nbsp;\u003cspan refid=\"Fig7\" class=\"InternalRef\"\u003e7\u003c/span\u003ea provides a visual representation of this CNN model's architecture. The analysis begins by reshaping the input data into a 2D array, followed by convolutional and pooling layers to extract pertinent features. The following steps include flattening and deploying dense layers to achieve multi-label classification. Figure\u0026nbsp;\u003cspan refid=\"Fig7\" class=\"InternalRef\"\u003e7\u003c/span\u003eb presents the confusion matrix results for gesture recognition, where the predicted and actual type counts are consistent, differing only in one or two instances. The training loss and accuracy are shown in Supplementary Fig. S14, highlighting the model's gesture recognition capabilities. Our results achieve 99.78% for precision, recall, and accuracy due to larger signal differences (Supplementary Fig. S11b) captured by CEAB electrodes among various gestures.\u003c/p\u003e \u003cp\u003eSubsequently, we utilize the algorithm to recognize gestures and instruct the robotic arms to replicate human gestures. Upon feeding the forearm biopotential data of various gestures into the trained models, the system returns a predicted label in approximately 150 ms. This label is then relayed to the robotic arm, instructing it to execute the corresponding gesture. To account for the time delay required for the robotic arm's movement, we set an appropriate delay before accepting the subsequent EMG input. Figure\u0026nbsp;\u003cspan refid=\"Fig7\" class=\"InternalRef\"\u003e7\u003c/span\u003ec-e demonstrates the hand gestures replication by the robotic arm. Details of forearm biopotential driving the robotic arm to imitate human gestures can be found in Supplementary Movie 4.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e"},{"header":"Discussions","content":"\u003cp\u003eIn conclusion, our study develops an ionic, flexible, dry, and self-healing electrode, named CEAB, through the utilization of deep eutectic solvents (DESs) and ionically cooperative conductors. We propose a streamlined method for crafting an ultrathin ionic electrode film, achieving a thickness of as small as 3.55 \u0026mu;m. The CEAB electrode has exceptional attributes, including high conductivity, minimized noise levels, and the uninterrupted capture of epidermal biopotential signals (e.g., ECG, sEMG, EEG) during dynamic detection. Through seamless integration with digital signal processing and analysis algorithms, using a one-channel wearable device, the electrode adeptly identifies abnormal EEG signals associated with depressive patients in clinical scenarios. Furthermore, this integration enables hand gesture repetition by robotic arms based on EMG signals, underscoring the transformative potential of this technology in health monitoring and human-machine interactions.\u003c/p\u003e"},{"header":"Methods","content":"\u003cp\u003eMaterials\u003c/p\u003e\n\u003cp\u003eCholine chloride (ChCl) (AR, 98%), Ethylene Glycol (AR, \u0026ge; 99%), Acrylic acid (AA) (AR, \u0026ge; 99%), Betaine (AR, 98%), Irgacure 2959 (AR, 98%),\u0026nbsp;were all purchased Shanghai Macklin Biochemical Company (China). All reagents are used without further purification.\u003c/p\u003e\n\u003cp\u003ePreparation of CEAB film\u003c/p\u003e\n\u003cp\u003eTo prepare the deep eutectic solvent (DES), we first mixed the hydrogen bond acceptor, choline chloride (ChCl), and the hydrogen bond donor, EG, in a 1:2 molar ratio. Following this, the mixture was stirred at 100 \u0026deg;C for 2 hours. Then, acrylic acid (AA) was dissolved in the DES. Subsequently, we added betaine and Irgacure 2959 to the solution and vigorously stirred the mixture for 1 hour until it dissolved completely, resulting in a clear precursor\u0026nbsp;solution. The precursor solution consisted of ChCl, EG, AA, and betaine in a molar ratio of 2:4:4:1, and the weight percentage of 2959 was 0.1%.\u0026nbsp;Afterward, the solution was allowed to stand overnight to eliminate all bubbles. Next, we coated the CEAB precursor between two PET release membranes pre-treated with silicone oil and affixed it to the surface of a flat glass mold. Afterward, another flat glass was positioned above. Uniform pressure was applied to the surface glass, and the duration was set as 5 min. The thickness of the precursor layer could be controlled by adjusting the pressure and duration applied to the glass surface. Finally, the glass mold was placed 5 centimeters above a 365-nanometer UV lamp with an output of 10 watts and exposure of 5 minutes. After photopolymerization, we rapidly removed the support PET film to obtain an independent ultra-thin organic gel film.\u003c/p\u003e\n\u003cp\u003eScanning electron microscope (SEM)\u003c/p\u003e\n\u003cp\u003eThe gross morphology of a freeze-dried CEAB film was observed via the Hitachi SU8010 under an accelerating voltage of 5\u0026nbsp;kV. The gel samples were then freeze-dried for 24\u0026nbsp;hours and sputter-coated with gold before imaging. For the gel/skin replica samples, a 3.55 and 200 \u0026micro;m gel film was cut into small pieces with sharp edges and then directly attached to an EcoflexTM rubber skin replica. To remove the remaining organic solvent, all samples were freeze-dried before being introduced to the SEM chamber.\u003c/p\u003e\n\u003cp\u003eFourier Transform Infrared Spectroscopy (FTIR)\u003c/p\u003e\n\u003cp\u003eThe samples were dried in a vacuum drying oven before testing. FTIR spectra of the samples were recorded using a spectrometer (Thermo Scientific Nicolet\u0026trade; iS50) within the wavenumber range of 400 to 4000 cm\u003csup\u003e-1\u003c/sup\u003e.\u003c/p\u003e\n\u003cp\u003eThermogravimetric Analysis (TGA)\u003c/p\u003e\n\u003cp\u003eAfter drying the gels, thermodynamic properties were analyzed using a thermogravimetric analyzer (NETZSCH\u0026apos;s STA 449 F3 Jupiter\u0026reg;). The initial mass of the sample was 5-10 mg, and it was heated from room temperature to 600 \u0026nbsp;℃ at a rate of 10 ℃/min under a nitrogen (N\u003csub\u003e2\u003c/sub\u003e) atmosphere.\u003c/p\u003e\n\u003cp\u003eDifferential Scanning Calorimeter (DSC)\u003c/p\u003e\n\u003cp\u003eThe thermal transition behavior of the polymers was investigated using differential scanning calorimetry (Mettler-Toledo DSC 3). The initial mass of the sample was 20-50 mg, and heating was performed at a rate of 10 ℃/min within the temperature range of \u0026ndash;60 to 100 ℃ under a nitrogen (N\u003csub\u003e2\u003c/sub\u003e) atmosphere.\u003c/p\u003e\n\u003cp\u003eIn the freezing stretch tests, Ag/AgCl gel and CEAB samples (6 cm in length, 1 cm in width, and 200 \u0026mu;m in thickness) were exposed to -30 \u0026nbsp;℃ for a duration of 24 hours. Following this cold exposure, the samples were twisted to assess their flexibility.\u003c/p\u003e\n\u003cp\u003eFor the moisture retention tests, CEAB and Ag/AgCl gels with identical weight and shape were kept at consistent temperatures of 37 ℃, while exposing them to varying relative humidity levels (RH: 10 % and 60 %) for a duration of 7 days. The weight of the samples was recorded at different time intervals during the test. Weight loss was calculated using the following formula:\u003c/p\u003e\n\u003cp\u003eWeight percent (%) =*100 %\u003c/p\u003e\n\u003cp\u003eHere, represents the initial weight of the gel, and is the weight after storage at a specific time.\u003c/p\u003e\n\u003cp\u003eElectrical Measurement\u003c/p\u003e\n\u003cp\u003eTo determine the ionic conductivities of the materials, we performed complex impedance measurements using an electrochemical workstation (PARSTAT 4000A, Princeton) across a frequency range from 0.1 Hz to 1 MHz, employing an alternating-current sine wave with an amplitude of 500 mV. In this procedure, a CEAB sample was cut into a cylindrical shape with dimensions of 6 mm in diameter and 3 mm in depth, and it was placed between two round steel electrodes. The material was kept at the specific temperature of -25, -20, 0, 20, 25, 40, and 60 ℃ for 30 min before testing.\u003c/p\u003e\n\u003cp\u003eTo obtain the bulk resistance (R) of the materials, we identified the intercept on the real axis of the Nyquist plot at a high frequency, utilizing the Z-view software. Subsequently, the conductivity of the CEAB was calculated using the formula \u0026sigma; = L / (A\u0026middot;R), where L represents the distance between the electrodes, and a signifies the cross-sectional area of the sample.\u003c/p\u003e\n\u003cp\u003eEvaluation of Mechanical Properties\u003c/p\u003e\n\u003cp\u003eThe tensile mechanical properties were assessed through uniaxial tensile and unconfined compression tests conducted using a LISHI LE3104 setup with a 10 N loading capacity. Different thickness of 3.55, 50, 150, 250, and 500 \u0026mu;m CEAB film was cut to dimensions of 100 mm \u0026times; 20 mm. To prevent the occurrence of cracks at the clamping positions, both ends of the sample were securely attached to two pieces of paper before being connected to the fixture. The test was conducted with a consistent peeling speed of 30 mm/min.\u003c/p\u003e\n\u003cp\u003eFor the assessment of interfacial adhesion properties, we employed a 90\u0026deg; peel-off test, as introduced in Supplementary Fig. S13 and Supplementary Movie S4 in the Supporting Information. In this evaluation, a 3.55, 50, 250, and 500 \u0026micro;m thick CEAB film, cut to dimensions of 100 mm \u0026times; 20 mm, was securely attached to a fresh porcine skin specimen, respectively. The test was conducted with a consistent peeling speed of 30 mm/min.\u003c/p\u003e\n\u003cp\u003eEvaluation of Self-Healing Property\u003c/p\u003e\n\u003cp\u003eThe precursor was cured for 5\u0026nbsp;min under UV light. After the photoreaction, a piece of elongated hydrogel was cut into two sections, which were then covered. After 8 hours, the two sections are completely self-healed under a photomicroscope.\u003c/p\u003e\n\u003cp\u003eIn vitro Biocompatibility Testing\u003c/p\u003e\n\u003cp\u003eThe biocompatibility of CEAB gel was assessed in vitro using the assay (CCK-8 kit, Yeasen, Guangzhou, China). A piece of CEAB gel (2.0 g) is immersed in 10 mL of deionized water for 24 h at room temperature. Then the mouse embryonic fibroblasts cell line (NIH3T3) was plated in a 96-well plate (2000 cells/well) with six parallel Wells (n=6) in which NIH3T3 cells were cultured in Dulbecco\u0026apos;s Modified Eagle Medium (DMEM) medium (HyClone, USA) and complete growth medium with 10% fetal bovine serum, 100 U mL-1 penicillin and 0.1 mg mL-1 streptomycin (Thermo Fisher Scientific, USA) at 37 \u0026deg; C in 5% CO\u003csub\u003e2\u003c/sub\u003e. The total volume of the medium used in this work was 100 uL. After 12h of cell culture, 10 \u0026mu;L CEAB gel extract was added to the medium, and the cells were then incubated at 37 ℃ for 24 h. At the time point to be measured, CCK-8 (10 \u0026mu;L), 10% of the total volume of the medium, was added and incubated for 2h in the dark. The absorbance of the 96-well plate was measured at 450 nm using a microplate reader (Tecan MicroplateReader Spark, USA). The cell viability is calculated according to the formula. The blank control was not seeded with NIH3T3 cells in the 96-well plate, and the negative control was only added DMEM complete medium after seeding NIH3T3 cells in the 96-well plate.\u003c/p\u003e\n\u003cp\u003e\u003cimg src=\"data:image/png;base64,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\"\u003e\u003cbr\u003e\u003c/p\u003e\n\u003cp\u003eWhere \u003cem\u003eOD\u003csub\u003eS\u003c/sub\u003e\u003c/em\u003e, \u003cem\u003eOD\u003csub\u003eC\u003c/sub\u003e\u003c/em\u003e, and \u003cem\u003eOD\u003csub\u003eN\u003c/sub\u003e\u003c/em\u003e were the \u003cem\u003eOD\u003c/em\u003e values of the samples, blank control, and negative control, respectively.\u003c/p\u003e\n\u003cp\u003eCell Recovery\u003c/p\u003e\n\u003cp\u003eThe frozen storage tube containing 1 mL of cell suspension was quickly shaken and thawed in a 37 ℃-water bath, and 4 mL of medium was added to mix well. Centrifuge at 1000 rpm for 3 min, discard the supernatant, add 1-2 mL culture medium, and then blow well. All cell suspensions were then added to a culture dish with an appropriate complete culture medium.\u003c/p\u003e\n\u003cp\u003eCell Passage\u003c/p\u003e\n\u003cp\u003eDiscard the upper culture medium and rinse the cells with calcium- and magnesium-free PBS 1-2 times. Add 1 mL of digestion solution (0.25% Trypsin-0.53mM EDTA) to the culture flask, and place the culture flask in a 37\u0026deg;C incubator for 1 min. Then 2-3 mL of complete culture medium is added to terminate digestion. After quick, gentle mixing, transfer the contents to a sterile centrifuge tube, centrifuge at 1000 rpm for 5 minutes, discard the supernatant, add 1-2 mL of culture medium, and resuspend the cells with the appropriate complete culture medium in new culture dishes.\u003c/p\u003e\n\u003cp\u003eWater Vapor Transmission Rate (WVTR) test\u003c/p\u003e\n\u003cp\u003eWater vapor permeability was evaluated by measuring the weight of water in a bottle where the opening was covered by the target films. Pure water (1 g) was placed in a sample bottle with a diameter of 15 mm. The CEAB gel film (200\u0026mu;m) was attached to the opening of the bottle with an adhesive (Araldite, Nichiban). This bottle was stored in a thermostatic chamber at 25\u0026thinsp; ℃ and a humidity of 42% for 5 days, and the subsequent decrease in weight was measured. As a comparison sample, a 4-\u0026micro;m-thick Parylene film, and a 50-\u0026mu;m-thick PDMS layer film were used. A bottle without any covering was used as the reference sample.\u003c/p\u003e\n\u003cp\u003eElectrode/skin contact impedance and biopotential signals extraction\u003c/p\u003e\n\u003cp\u003eThe electrode/skin contact impedance was measured by positioning two electrodes, namely commercial Ag/AgCl gel electrodes (1 mm, 1.77 cm\u0026sup2;) or CEAB electrodes (1.5 mm, 1.77 cm\u0026sup2;), at a distance of 7 cm on the anterior surface of a volunteer\u0026apos;s forearm. These electrodes were then linked to the electrochemical workstation (CHI 760E). Impedance spectra were captured within the frequency range of 1 to 10\u003csup\u003e4\u003c/sup\u003e Hz, with the AC voltage amplitude fixed at 0.1 V.\u003c/p\u003e\n\u003cp\u003eThe EMG signal recording setup comprises two main components: a microcontroller (Arduino UNO microcontroller) and a detector (Muscle SpikerBox Pro). The EMG signals are captured by the Spikershield box through potential differences between the working electrodes on the target area and the reference electrodes. Signal processing algorithms are applied to the collected data using Python for fundamental signal analysis (Root-Mean-Square).\u003c/p\u003e\n\u003cp\u003eThe ECG data acquisition device employs a portable, wearable chest adhesive ECG sensor based on the BMD101 chip. The BMD101 chip comprises two main components: a low-noise amplifier and an ADC (Analog-to-Digital Converter). These components work in tandem, with the BMD101 chip capturing and amplifying faint bioelectrical signals originating from the heart via chest electrodes. Once the ECG signals are converted into digital form by the ADC, the BMD101 chip processes them digitally, including tasks like filtering, sampling, and data compression. Finally, the chip transmits the data to a smartphone via Bluetooth, enabling real-time monitoring of cardiac activity and subsequent recording and analysis. The ECG signals were analyzed using the Python envelope function.\u003c/p\u003e\n\u003cp\u003eIn EMG testing, in cases recording the grip force muscle potential and collecting EMG signals during various hand gestures, two CEAB electrodes were placed on the forearm, with a CEAB film used as the reference electrode on the posterior elbow. These electrodes recorded signals generated by the brachioradialis muscle. For cases involving the collection of EMG signals during knee reflex tests, two CEAB electrodes were positioned on the anterior thigh, and a CEAB film was applied to the knee as the reference electrode. These electrodes captured signals generated by the quadriceps muscle. In cases where EMG signals during finger flexion and extension were collected, two CEAB electrodes were positioned on the forearm. In cases where facial EMG is collected when a volunteer smiles, two CEAB electrodes are attached to the risorius and zygomaticus, and a reference CEAB electrode is attached behind the ear. The Ag/AgCl gel electrodes are also attached to the same locations in the cases as the comparison.\u003c/p\u003e\n\u003cp\u003eThe ECG signals were acquired by placing two CEAB film electrodes in specific positions: one below the clavicle, in the 3rd intercostal space, near the heart, and the other in a position symmetrically aligned with the midline of the chest. Subsequently, these electrodes were connected to an ECG sensor based on the BMD101 chip\u0026apos;s signal recording device. The acquired ECG signals could then be monitored in real time on a laptop and subsequently analyzed using Python\u0026apos;s envelope function.\u003c/p\u003e\n\u003cp\u003eIn EEG measurements, CEAB electrodes were positioned according to the 10-20 system for electrode placement on the head. The CEAB electrode was located at the FP1 site (at the left side of the forehead) as the working electrode, with the FPz site (at the frontal region of the brain) serving as the reference electrode. Another CEAB film electrode was placed behind the ear to serve as the ground electrode.\u003c/p\u003e\n\u003cp\u003eMotion artifact characterization. The electromechanical vibrator was placed near the working electrodes (about 2 cm) to induce skin vibration, which is similar to vibration near the chest during body movement.\u003c/p\u003e\n\u003cp\u003eLong-time monitoring of EEG\u003c/p\u003e\n\u003cp\u003eBrain activity was assessed using EEG signals recorded with an ECG sensor based on the BMD101 chip. The working electrode was positioned at the FP1 site, the reference electrode at the FPz site, and the ground electrode behind the ear. During the 12-hour monitoring period, the volunteer slept for 1 hour, engaged in 0.5 hours of exercise, and finally returned to a state of calm without removing the CEAB electrodes. Subsequently, the EEG signal is analyzed using Python and Fast Fourier Transformation.\u003c/p\u003e\n\u003cp\u003eDepression detection\u003c/p\u003e\n\u003cp\u003eDepression data collection. We recruited 6 depressed and 6 healthy volunteers from the Fifth Affiliated Hospital of Wenzhou Medical University in China (all the depressed volunteers were diagnosed by the Hamilton Depression Scale in the hospital). EEG signals were recorded by a portable TGAM EEG device with a single channel. The ring-shaped EEG sensor was tied to the head, and all people were asked to keep calm and their eyes closed for 1 minute without any interruption.\u003c/p\u003e\n\u003cp\u003eDepression data preprocess. Building upon the TGAM module, the embedded algorithms filtered power line frequency noise. The dataset encompassed both the raw EEG original values and transformed values across various frequency bands. The data were firstly cleaned by deleting invalid \u0026ldquo;0\u0026rdquo; values received at the beginning stage, then aligned following the sampling frequency of 512 Hz. A 2-second duration of data was set as a sample, with an overlap of 50%.\u003c/p\u003e\n\u003cp\u003eFeatures extraction. Twelve linear features including original value mean, original value \u0026sigma; (standard deviation), attention mean, attention \u0026sigma;, \u0026delta; mean, \u0026theta; mean, low \u0026alpha; mean, high \u0026alpha; mean, low \u0026beta; mean, high \u0026beta; mean, low \u0026gamma; mean, mid \u0026gamma; mean, low \u0026beta; mean / \u0026theta; mean, high \u0026beta; mean / \u0026theta; mean, and two nonlinear features including Co complexity and Power Spectral Entropy were extracted as features for normal, depression classification.\u003c/p\u003e\n\u003cp\u003eMachine learning models construction. SVM, KNN, XGBOOST, and RF were constructed by sklearn toolkit, python 3.8.\u003c/p\u003e\n\u003cp\u003eHand gesture replication by robotic hands\u003c/p\u003e\n\u003cp\u003eGesture dataset collection. Ten volunteers are instructed to repeat six different gestures\u0026mdash;six, eight, good, yeah, ok, and fist\u0026mdash;each lasting 5 seconds, with a 5-second rest between consecutive gestures to prevent muscle fatigue. This entire sequence is collected over 1 minute and repeated for ten volunteers.\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eData preprocess. The gesture data is firstly sliced at the length of 1000, overlapped at 95%, normalized, and then reshaped as 20\u0026times;50 dimension.\u003c/p\u003e\n\u003cp\u003eCNN model construction. The CNN architecture is established by the Keras toolkit in Python 3.8.\u003c/p\u003e"},{"header":"Declarations","content":"\u003cp\u003e\u003cstrong\u003eAuthorship contribution\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eConceptualization: Zhenglin Chen, Likun Zhang, Dongmei Yu, Peiwu Qin\u003c/p\u003e\n\u003cp\u003eMethodology: Likun Zhang, Huazhang Ying, Zhicheng Du, Ziwu Song, Jiaju Chen.\u003c/p\u003e\n\u003cp\u003eInvestigation: Zhenglin Chen, Likun Zhang.\u003c/p\u003e\n\u003cp\u003eVisualization: Likun Zhang, Zhenglin Chen, Huazhang Ying, Xi Yuan, Ping Zhang, Jiaju Chen.\u003c/p\u003e\n\u003cp\u003eSupervision: Dongmei Yu, Peiwu Qin, Zhenglin Chen, Chenggang Yan.\u003c/p\u003e\n\u003cp\u003eWriting\u0026mdash;original draft:\u0026nbsp;Likun Zhang, Zhenglin chen.\u003c/p\u003e\n\u003cp\u003eWriting\u0026mdash;review \u0026amp; editing: Zhenglin Chen, Peiwu Qin, Wenbo Ding, Canhui Yang, Vijay Pandey, Xinhui Xing, Jiansong Ji, Chenggang Yan.\u003c/p\u003e\n\u003cp\u003e\u0026nbsp;\u003cstrong\u003eCode availability\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThe codes for EMG, EEG, ECG signal recording, and analysis used in this study are available from the corresponding authors upon request.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eDeclaration of competing interest\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThe authors declare that they have no competing interests. The authors claim that none of the material in the paper has been published or is under consideration for publication elsewhere. All authors have seen the manuscript and approved to submit to your journal.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eEthical declaration\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThe study protocol was thoroughly reviewed and approved by the ethical committee of the Tsinghua Shenzhen International Graduate School, Tsinghua University (approval number 2023-F036).\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAcknowledgments\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eWe thank the support from the National Natural Science Foundation of China 31970752,32350410397; Science, Technology, Innovation Commission of Shenzhen Municipality, JCYJ20220530143014032, JCYJ20230807113017035, WDZC20200820173710001, Shenzhen Medical Research Funds, D2301002; Department of Chemical Engineering-iBHE special cooperation joint fund project, DCE-iBHE-2022-3; Tsinghua Shenzhen International Graduate School Cross-disciplinary Research and Innovation Fund Research Plan, JC2022009; and Bureau of Planning, Land and Resources of Shenzhen Municipality (2022) 207.\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\u003cli\u003e\u003cspan\u003eImani, S. \u003cem\u003eet al.\u003c/em\u003e A wearable chemical\u0026ndash;electrophysiological hybrid biosensing system for real-time health and fitness monitoring. 7, 11650 (2016).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLiu, Y., Pharr, M. \u0026amp; Salvatore, G. A. Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring. ACS Nano 11, 9614\u0026ndash;9635, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1021/acsnano.7b04898\u003c/span\u003e\u003cspan address=\"10.1021/acsnano.7b04898\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2017).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eJang, K.-I. \u003cem\u003eet al.\u003c/em\u003e Self-assembled three dimensional network designs for soft electronics. 8, 15894 (2017).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhou, Z., Zhang, H., Liu, J. \u0026amp; Huang, W. J. G. Flexible electronics from intrinsically soft materials. 6, 100051 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBihar, E. \u003cem\u003eet al.\u003c/em\u003e Fully printed electrodes on stretchable textiles for long-term electrophysiology. 2, 1600251 (2017).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eChen, Z., Wang, Y. J. S. \u0026amp; Diagnostics. Organic ionic fluid-based wearable sensors for healthcare. 1, 598\u0026ndash;613 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhao, Y. \u003cem\u003eet al.\u003c/em\u003e Ultra-conformal skin electrodes with synergistically enhanced conductivity for long-time and low-motion artifact epidermal electrophysiology. 12, 4880 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKim, T. H. \u003cem\u003eet al.\u003c/em\u003e Flexible biomimetic block copolymer composite for temperature and long-wave infrared sensing. 9, eade0423, doi:doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1126/sciadv.ade0423\u003c/span\u003e\u003cspan address=\"10.1126/sciadv.ade0423\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCheng, L., Li, J., Guo, A. \u0026amp; Zhang, J. Recent advances in flexible noninvasive electrodes for surface electromyography acquisition. npj Flexible Electronics 7, 39, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1038/s41528-023-00273-0\u003c/span\u003e\u003cspan address=\"10.1038/s41528-023-00273-0\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYuk, H., Wu, J. \u0026amp; Zhao, X. J. N. R. M. Hydrogel interfaces for merging humans and machines. 7, 935\u0026ndash;952 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eJinkins, K. R. \u003cem\u003eet al.\u003c/em\u003e Thermally switchable, crystallizable oil and silicone composite adhesives for skin-interfaced wearable devices. 8, eabo0537, doi:doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1126/sciadv.abo0537\u003c/span\u003e\u003cspan address=\"10.1126/sciadv.abo0537\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eChen, F. \u003cem\u003eet al.\u003c/em\u003e Wet-Adaptive Electronic Skin. 35, 2305630 (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHao, Y. \u003cem\u003eet al.\u003c/em\u003e A Stretchable, Breathable, And Self-Adhesive Electronic Skin with Multimodal Sensing Capabilities for Human‐Centered Healthcare. 33, 2303881 (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLim, C. \u003cem\u003eet al.\u003c/em\u003e Stretchable conductive nanocomposite based on alginate hydrogel and silver nanowires for wearable electronics. 7 (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLim, C. \u003cem\u003eet al.\u003c/em\u003e Tissue-like skin-device interface for wearable bioelectronics by using ultrasoft, mass-permeable, and low-impedance hydrogels. 7, eabd3716 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWang, B. \u0026amp; Facchetti, A. J. A. M. Mechanically flexible conductors for stretchable and wearable e-skin and e‐textile devices. 31, 1901408 (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWang, J. \u003cem\u003eet al.\u003c/em\u003e Ultrastretchable E-Skin Based on Conductive Hydrogel Microfibers for Wearable Sensors. 2305951 (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eXun, X. \u003cem\u003eet al.\u003c/em\u003e Highly robust and self-powered electronic skin based on tough conductive self-healing elastomer. 14, 9066\u0026ndash;9072 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKhatib, M., Zohar, O., Saliba, W. \u0026amp; Haick, H. J. A. M. A multifunctional electronic skin empowered with damage mapping and autonomic acceleration of self-healing in designated locations. 32, 2000246 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKang, J. \u003cem\u003eet al.\u003c/em\u003e Tough and water-insensitive self‐healing elastomer for robust electronic skin. 30, 1706846 (2018).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLin, X. \u003cem\u003eet al.\u003c/em\u003e Biocompatible multifunctional e-skins with excellent self-healing ability enabled by clean and scalable fabrication. 13, 1\u0026ndash;14 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eFernandez, M., Pallas-Areny, R. J. B. i. \u0026amp; technology. Ag-AgCl electrode noise in high-resolution ECG measurements. 34, 125\u0026ndash;130 (2000).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHuigen, E., Peper, A., Grimbergen, C. J. M., engineering, b. \u0026amp; computing. Investigation into the origin of the noise of surface electrodes. 40, 332\u0026ndash;338 (2002).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMeziane, N., Webster, J., Attari, M. \u0026amp; Nimunkar, A. J. P. m. Dry electrodes for electrocardiography. 34, R47 (2013).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eChi, Y. M., Jung, T.-P. \u0026amp; Cauwenberghs, G. J. I. r. i. b. e. Dry-contact and noncontact biopotential electrodes: Methodological review. 3, 106\u0026ndash;119 (2010).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDe Luca, C., Le Fever, R., Stulen, F. J. M., engineering, b. \u0026amp; computing. Pasteless electrode for clinical use. 17, 387\u0026ndash;390 (1979).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHoffmann, K.-P., Ruff, R. \u0026amp; Poppendieck, W. in 2006 \u003cem\u003eInternational Conference of the IEEE Engineering in Medicine and Biology Society.\u003c/em\u003e 2239\u0026ndash;2242 (IEEE).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eFan, D. \u003cem\u003eet al.\u003c/em\u003e Self-shrinking soft demoulding for complex high-aspect-ratio microchannels. 13, 5083 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eChen, Z. \u003cem\u003eet al.\u003c/em\u003e Temperature tolerant all-solid-state touch panel with high stretchablity, transparency and self-healing ability. 451, 138672 (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZou, Y., Nathan, V., Jafari, R. J. I. j. o. b. \u0026amp; informatics, h. Automatic identification of artifact-related independent components for artifact removal in EEG recordings. 20, 73\u0026ndash;81 (2014).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGreen, R. M. \u003cem\u003eet al.\u003c/em\u003e Benefits, shortcomings, and costs of EEG monitoring. 201, 785 (1985).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRudiger, A., Hellermann, J. P., Mukherjee, R., Follath, F. \u0026amp; Turina, J. J. T. A. j. o. e. m. Electrocardiographic artifacts due to electrode misplacement and their frequency in different clinical settings. 25, 174\u0026ndash;178 (2007).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNie, J., Fu, J. \u0026amp; He, Y. J. S. Hydrogels: the next generation body materials for microfluidic chips? 16, 2003797 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZainal, S. H. \u003cem\u003eet al.\u003c/em\u003e Preparation of cellulose-based hydrogel: A review. 10, 935\u0026ndash;952 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eOhm, Y. \u003cem\u003eet al.\u003c/em\u003e An electrically conductive silver\u0026ndash;polyacrylamide\u0026ndash;alginate hydrogel composite for soft electronics. 4, 185\u0026ndash;192 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHu, C. \u003cem\u003eet al.\u003c/em\u003e Stable, strain-sensitive conductive hydrogel with antifreezing capability, remoldability, and reusability. 10, 44000\u0026ndash;44010 (2018).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhao, X. \u003cem\u003eet al.\u003c/em\u003e Bioinspired ultra-stretchable and anti-freezing conductive hydrogel fibers with ordered and reversible polymer chain alignment. 9, 3579 (2018).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHan, L. \u003cem\u003eet al.\u003c/em\u003e Mussel-inspired adhesive and conductive hydrogel with long‐lasting moisture and extreme temperature tolerance. 28, 1704195 (2018).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhang, Q., Vigier, K. D. O., Royer, S. \u0026amp; J\u0026eacute;r\u0026ocirc;me, F. J. C. S. R. Deep eutectic solvents: syntheses, properties and applications. 41, 7108\u0026ndash;7146 (2012).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSmith, E. L., Abbott, A. P. \u0026amp; Ryder, K. S. J. C. r. Deep eutectic solvents (DESs) and their applications. 114, 11060\u0026ndash;11082 (2014).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eStefanovic, R., Ludwig, M., Webber, G. B., Atkin, R. \u0026amp; Page, A. J. J. P. C. C. P. Nanostructure, hydrogen bonding and rheology in choline chloride deep eutectic solvents as a function of the hydrogen bond donor. 19, 3297\u0026ndash;3306 (2017).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhao, B.-Y. \u003cem\u003eet al.\u003c/em\u003e Biocompatible deep eutectic solvents based on choline chloride: characterization and application to the extraction of rutin from Sophora japonica. 3, 2746\u0026ndash;2755 (2015).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePaiva, A. \u003cem\u003eet al.\u003c/em\u003e Natural deep eutectic solvents\u0026ndash;solvents for the 21st century. 2, 1063\u0026ndash;1071 (2014).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eQin, H., Owyeung, R. E., Sonkusale, S. R. \u0026amp; Panzer, M. J. J. J. o. M. C. C. Highly stretchable and nonvolatile gelatin-supported deep eutectic solvent gel electrolyte-based ionic skins for strain and pressure sensing. 7, 601\u0026ndash;608 (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLai, C.-W., Yu, S.-S. J. A. a. m. \u0026amp; interfaces. 3D printable strain sensors from deep eutectic solvents and cellulose nanocrystals. 12, 34235\u0026ndash;34244 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLi, G. \u003cem\u003eet al.\u003c/em\u003e A stretchable and adhesive ionic conductor based on polyacrylic acid and deep eutectic solvents. npj Flexible Electronics 5, 23, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1038/s41528-021-00118-8\u003c/span\u003e\u003cspan address=\"10.1038/s41528-021-00118-8\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKang, J., Tok, J. B. H. \u0026amp; Bao, Z. Self-healing soft electronics. Nature Electronics 2, 144\u0026ndash;150, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1038/s41928-019-0235-0\u003c/span\u003e\u003cspan address=\"10.1038/s41928-019-0235-0\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eVatankhah-Varnosfaderani, M. \u003cem\u003eet al.\u003c/em\u003e Chameleon-like elastomers with molecularly encoded strain-adaptive stiffening and coloration. Science 359, 1509\u0026ndash;1513, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1126/science.aar5308\u003c/span\u003e\u003cspan address=\"10.1126/science.aar5308\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2018).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eStorm, C., Pastore, J. J., MacKintosh, F. C., Lubensky, T. C. \u0026amp; Janmey, P. A. Nonlinear elasticity in biological gels. Nature 435, 191\u0026ndash;194, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1038/nature03521\u003c/span\u003e\u003cspan address=\"10.1038/nature03521\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2005).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhang, W., Wu, B., Sun, S. \u0026amp; Wu, P. Skin-like mechanoresponsive self-healing ionic elastomer from supramolecular zwitterionic network. Nature Communications 12, 4082, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1038/s41467-021-24382-4\u003c/span\u003e\u003cspan address=\"10.1038/s41467-021-24382-4\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eReilly, R. B., Lee, T. C. J. T. \u0026amp; Care, H. Electrograms (ecg, eeg, emg, eog). 18, 443\u0026ndash;458 (2010).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCheng, S. \u003cem\u003eet al.\u003c/em\u003e Ultrathin Hydrogel Films toward Breathable Skin-Integrated Electronics. 35, 2206793 (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLim, C. Y. \u003cem\u003eet al.\u003c/em\u003e Desulfurization performance of choline chloride-based deep eutectic solvents in the presence of graphene oxide. 7, 97 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSarma, A. V. \u003cem\u003eet al.\u003c/em\u003e Solution NMR of a 463-residue phosphohexomutase: domain 4 mobility, substates, and phosphoryl transfer defect. 51, 807\u0026ndash;819 (2012).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSmedley, S. I. \u003cem\u003eThe interpretation of ionic conductivity in liquids\u003c/em\u003e. (Springer Science \u0026amp; Business Media, 2012).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGuimar\u0026atilde;es, C. F., Gasperini, L., Marques, A. P. \u0026amp; Reis, R. L. The stiffness of living tissues and its implications for tissue engineering. Nature Reviews Materials 5, 351\u0026ndash;370, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1038/s41578-019-0169-1\u003c/span\u003e\u003cspan address=\"10.1038/s41578-019-0169-1\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLiu, S., Rao, Y., Jang, H., Tan, P. \u0026amp; Lu, N. J. M. Strategies for body-conformable electronics. 5, 1104\u0026ndash;1136 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAshbaugh, D. R. \u003cem\u003eQuantitative-qualitative friction ridge analysis: an introduction to basic and advanced ridgeology\u003c/em\u003e. (CRC press, 1999).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHurst, J. W. J. C. Naming of the waves in the ECG, with a brief account of their genesis. 98, 1937\u0026ndash;1942 (1998).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eFujimura, T., Hotta, M. J. S. R. \u0026amp; Technology. The preliminary study of the relationship between facial movements and wrinkle formation. 18, 219\u0026ndash;224 (2012).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKandel, E. R. \u003cem\u003eet al. Principles of neural science\u003c/em\u003e. Vol. 4 (McGraw-hill New York, 2000).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMari-Acevedo, J., Yelvington, K. \u0026amp; Tatum, W. O. in \u003cem\u003eHandbook of Clinical Neurology\u003c/em\u003e Vol. 160 (eds Kerry H. Levin \u0026amp; Patrick Chauvel) 143\u0026ndash;160 (Elsevier, 2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eFrench, J. A. in \u003cem\u003eRowan's Primer of EEG (Second Edition)\u003c/em\u003e (eds Lara V. Marcuse, Madeline C. Fields, \u0026amp; Jiyeoun Yoo) vii (Elsevier, 2016).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eTwitmyer, E. B. J. J. o. E. P. A study of the knee jerk. 103, 1047 (1974).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHorwitz, A. V. \u0026amp; Wakefield, J. C. \u003cem\u003eThe loss of sadness: How psychiatry transformed normal sorrow into depressive disorder\u003c/em\u003e. (Oxford University Press, 2007).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eFekadu, N., Shibeshi, W. \u0026amp; Engidawork, E. J. J. D. A. Major depressive disorder: pathophysiology and clinical management. 6, 255\u0026ndash;257 (2017).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBaroiu, L. \u003cem\u003eet al.\u003c/em\u003e Assessment of Depression in Patients with COVID-19. 12, 254\u0026ndash;264 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ede Aguiar Neto, F. S., Rosa, J. L. G. J. N. \u0026amp; Reviews, B. Depression biomarkers using non-invasive EEG: A review. 105, 83\u0026ndash;93 (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eVoetterl, H. T. S. \u003cem\u003eet al.\u003c/em\u003e Alpha peak frequency-based Brainmarker-I as a method to stratify to pharmacotherapy and brain stimulation treatments in depression. Nature Mental Health 1, 1023\u0026ndash;1032, doi:\u003cspan class=\"ExternalRef\"\u003e\u003cspan class=\"RefSource\"\u003e10.1038/s44220-023-00160-7\u003c/span\u003e\u003cspan address=\"10.1038/s44220-023-00160-7\" targettype=\"DOI\" class=\"RefTarget\"\u003e\u003c/span\u003e\u003c/span\u003e (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eM\u0026aacute;rton, L., Brassai, S. T., Bak\u0026oacute;, L. \u0026amp; Losonczi, L. J. P. T. Detrended fluctuation analysis of EEG signals. 12, 125\u0026ndash;132 (2014).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDuan, L. \u003cem\u003eet al.\u003c/em\u003e Machine learning approaches for MDD detection and emotion decoding using EEG signals. 14, 284 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYin, L., Zhang, C. \u0026amp; Cui, Z. J. C. C. Experimental research on real-time acquisition and monitoring of wearable EEG based on TGAM module. 151, 76\u0026ndash;85 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWu, Y., Xie, N. J. C. \u0026amp; Medicine, M. M. i. Attention Optimization Method for EEG via the TGAM. 2020 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAcharya, U. R. \u003cem\u003eet al.\u003c/em\u003e Computer-aided diagnosis of depression using EEG signals. 73, 329\u0026ndash;336 (2015).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHuang, S. \u003cem\u003eet al.\u003c/em\u003e Applications of support vector machine (SVM) learning in cancer genomics. 15, 41\u0026ndash;51 (2018).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCai, H. \u003cem\u003eet al.\u003c/em\u003e Feature-level fusion approaches based on multimodal EEG data for depression recognition. 59, 127\u0026ndash;138 (2020).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZulfiker, M. S., Kabir, N., Biswas, A. A., Nazneen, T. \u0026amp; Uddin, M. S. J. C. r. i. b. s. An in-depth analysis of machine learning approaches to predict depression. 2, 100044 (2021).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCacheda, F., Fernandez, D., Novoa, F. J. \u0026amp; Carneiro, V. J. J. o. m. I. r. Early detection of depression: social network analysis and random forest techniques. 21, e12554 (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMenze, B. H. \u003cem\u003eet al.\u003c/em\u003e A comparison of random forest and its Gini importance with standard chemometric methods for the feature selection and classification of spectral data. 10, 1\u0026ndash;16 (2009).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eJamal, R. \u0026amp; Kullar, M. Multivariate Time-Series Signals of Affect Dynamics and Neural Oscillations with Suggested Applications to Technology to Identify Depression Risk. (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRoh, S.-C., Park, E.-J., Shim, M. \u0026amp; Lee, S.-H. J. J. o. a. d. EEG beta and low gamma power correlates with inattention in patients with major depressive disorder. 204, 124\u0026ndash;130 (2016).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWatts, D. \u003cem\u003eet al.\u003c/em\u003e Predicting treatment response using EEG in major depressive disorder: A machine-learning meta-analysis. 12, 332 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMeerwijk, E. L., Ford, J. M. \u0026amp; Weiss, S. J. J. B. p. Resting-state EEG delta power is associated with psychological pain in adults with a history of depression. 105, 106\u0026ndash;114 (2015).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDe Stefani, E. \u0026amp; De Marco, D. J. F. i. P. Language, gesture, and emotional communication: An embodied view of social interaction. 10, 2063 (2019).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhang, R. \u003cem\u003eet al.\u003c/em\u003e RCMNet: A deep learning model assists CAR-T therapy for leukemia. 150, 106084 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBhardwaj, V. \u003cem\u003eet al.\u003c/em\u003e Machine learning for endometrial cancer prediction and prognostication. 12, 852746 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLiu, Y. \u003cem\u003eet al.\u003c/em\u003e Mixed-UNet: Refined class activation mapping for weakly-supervised semantic segmentation with multi-scale inference. 4, 1036934 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhang, L. \u003cem\u003eet al.\u003c/em\u003e AI-boosted CRISPR-Cas13a and total internal reflection fluorescence microscopy system for SARS-CoV-2 detection. 3, 1015223 (2022).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eQi, J., Ma, L., Cui, Z., Yu, Y. J. C. \u0026amp; Systems, I. Computer vision-based hand gesture recognition for human-robot interaction: a review. 1\u0026ndash;26 (2023).\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKim, J., Mastnik, S. \u0026amp; Andr\u0026eacute;, E. in \u003cem\u003eProceedings of the 13th international conference on Intelligent user interfaces.\u003c/em\u003e 30\u0026ndash;39.\u003c/span\u003e\u003c/li\u003e\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[{"identity":"8d43197f-548e-407a-84dd-81e633d64653","identifier":"10.13039/501100001809","name":"National Natural Science Foundation of China","awardNumber":"31970752,32350410397","order_by":0}],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":true,"hideJournal":true,"highlight":"","institution":"Tsinghua University","isAcceptedByJournal":false,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"
[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true},"keywords":"ultrathin, skin-like mechanoresponsive, compliant, seamless, ionic conductive electrode","lastPublishedDoi":"10.21203/rs.3.rs-3892812/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-3892812/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003eFlexible ionic conductive electrodes, as a fundamental component for electrical signal transmission, play a crucial role in skin-surface electronic devices. Developing a skin-seamlessly electrode that can effectively capture long-term, artifacts-free, and high-quality electrophysiological signals, remains a challenge. Herein, we report an ultra-thin and dry electrode consisting of deep eutectic solvent (DES) and zwitterions (CEAB), which exhibit significantly lower reactance and noise in both static and dynamic monitoring compared to standard Ag/AgCl gel electrodes. Our electrodes have skin-like mechanical properties (strain-rigidity relationship and flexibility), outstanding adhesion, and high electrical conductivity. Consequently, they excel in consistently capturing high-quality epidermal biopotential signals, such as the electrocardiogram (ECG), electromyogram (EMG), and electroencephalogram (EEG) signals. Furthermore, we demonstrate the promising potential of the electrodes in clinical applications by effectively distinguishing aberrant EEG signals associated with depressive patients. Meanwhile, through the integration of CEAB electrodes with digital processing and advanced algorithms, valid gesture control of artificial limbs based on EMG signals is achieved, highlighting its capacity to significantly enhance human-machine interaction.\u003c/p\u003e","manuscriptTitle":"A 3.55-μm ultrathin, skin-like mechanoresponsive, compliant, and seamless ionic conductive electrode for epidermal electrophysiological signal acquisition and human-machine-interaction","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2024-01-25 16:14:55","doi":"10.21203/rs.3.rs-3892812/v1","editorialEvents":[{"type":"communityComments","content":0}],"status":"published","journal":{"display":true,"email":"
[email protected]","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"44d09a9f-55e4-4d6f-a610-51f3314c5896","owner":[],"postedDate":"January 25th, 2024","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"posted","subjectAreas":[{"id":28333595,"name":"Electronic Materials and Devices"}],"tags":[],"updatedAt":"2024-01-25T16:14:55+00:00","versionOfRecord":[],"versionCreatedAt":"2024-01-25 16:14:55","video":"","vorDoi":"","vorDoiUrl":"","workflowStages":[]},"version":"v1","identity":"rs-3892812","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-3892812","identity":"rs-3892812","version":["v1"]},"buildId":"7rjqhiLT3MXkJMwkYKINL","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.