Electret Integrated Magnetic Field Sensor Based on Magnetostrictive Polymer Composite with nT Resolution

preprint OA: closed CC-BY-4.0
📄 Open PDF Full text JSON View at publisher

Abstract

Abstract The pursuit for advanced magnetoelectric field sensors has gained momentum, driven by applications in various fields, ranging from biomedical applications to soft robotics and the automotive sector. In this context, a capacitive read-out based magnetostrictive polymer composite (MPC) sensor element is introduced, offering a new perspective on magnetic field detection. The sensor element's unique feature is the possibility to independently tailor its mechanical and magnetic properties. When compared to other composite-based magnetic field sensors, the limit of detection (LoD) is three orders of magnitude lower (95.6 nT/√Hz at a resonance frequency of 160.5 Hz). In contrast to other electret-based ME sensors, the LoD is reduced by a factor of 20. To the best of the authors' knowledge, this work marks the first comprehensive attempt to characterize a sensor magnetically, aligning with the thorough assessment standards of ME sensors. This study aims to narrow the disparity between established magnetic field sensors, featuring consistent characterization protocols, and the novel MPC sensors, which often undergo limited magnetic characterization as part of their evaluation. The presented sensor, built from readily available materials, offers a versatile and tuneable platform for magnetic field detection, and ongoing research aims to unlock its full potential in diverse applications.
Full text 80,825 characters · extracted from preprint-html · click to expand
Electret Integrated Magnetic Field Sensor Based on Magnetostrictive Polymer Composite with nT Resolution | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Article Electret Integrated Magnetic Field Sensor Based on Magnetostrictive Polymer Composite with nT Resolution Lukas Zimoch, Stefan Schröder, Eric Elzenheimer, Sören Kaps, Thomas Strunskus, and 3 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-4600004/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 10 Jan, 2025 Read the published version in Scientific Reports → Version 1 posted 11 You are reading this latest preprint version Abstract The pursuit for advanced magnetoelectric field sensors has gained momentum, driven by applications in various fields, ranging from biomedical applications to soft robotics and the automotive sector. In this context, a capacitive read-out based magnetostrictive polymer composite (MPC) sensor element is introduced, offering a new perspective on magnetic field detection. The sensor element's unique feature is the possibility to independently tailor its mechanical and magnetic properties. When compared to other composite-based magnetic field sensors, the limit of detection (LoD) is three orders of magnitude lower (95.6 nT/√Hz at a resonance frequency of 160.5 Hz). In contrast to other electret-based ME sensors, the LoD is reduced by a factor of 20. To the best of the authors' knowledge, this work marks the first comprehensive attempt to characterize a sensor magnetically, aligning with the thorough assessment standards of ME sensors. This study aims to narrow the disparity between established magnetic field sensors, featuring consistent characterization protocols, and the novel MPC sensors, which often undergo limited magnetic characterization as part of their evaluation. The presented sensor, built from readily available materials, offers a versatile and tuneable platform for magnetic field detection, and ongoing research aims to unlock its full potential in diverse applications. Magnetostrictive Polymer Composite (MPC) Nanoscale Sculptured Aluminum Electret Magnetic Field Sensor Sensor Evaluation Figures Figure 1 Figure 2 Figure 3 1 Introduction The market for magnetoelectric field sensors is experiencing growth due to increasing demand in various industries, such as the automotive sector and especially in biomedical applications for systems with navigation, orientation, and motion tracking. However, they can also be utilized for electronic skins, smart textiles, soft robotics and actuators 1 . The most advanced sensors that are capable of detecting magnetic signals as small as the signals of the human brain are superconducting quantum interference devices (SQUIDs). 2,3 Due to their bulky size and requirement for cryogenic cooling, they result in significant costs, making their widespread use challenging 4,5 . An alternative to SQUIDs are optically pumped magnetometers (OPMs), which achieve performances similar to those of SQUIDs without the need for cryogenic cooling 6,7 . Sensor such as fluxgate magnetometers or Hall effect sensors are limited by magnetic noise and their sensitivity cannot be reduced further 8 . Another common approach for magnetoelectric field sensors is to utilize a combination of a magnetostrictive material, which is sensitive to magnetic fields, and a mechanically linked piezoelectric material, which generates an electrical signal proportional to the magnetic field of interest. These sensors are usually referred as Magnetoelectric (ME) sensors 9,10 . An alternative method involves the integration of a fiber Bragg grating (FBG) with a magnetostrictive cantilever. The deformation of the FBG modifies its reflection spectrum, which can be related to the magnetic signal 11,12 . Cantilever-based sensors face limitations in adjusting mechanical properties independently from the magnetic properties. Cantilever-based sensors have the drawback, that it is not easy to freely change the mechanical properties without changing the magnetic properties. Attempts were undertaken by utilizing an electret to manipulate the resonance frequency of the cantilever resulting in an undamping, which can be related to the electrostatic interactions 13 . The sensor presented in this work uses a magnetostrictive polymer composite, which consists of ferromagnetic particles embedded in a polymer matrix. The mechanical properties are defined by the matrix material, which can be tuned or totally replaced by a different polymer. This gives the opportunity to change the resonance frequency of the sensor without changing the geometry, or to protect the magnetic particles from environmental conditions such as corrosion. On the other hand, the type or number of magnetic particles can be changed. This metamaterial emerges as a compelling candidate for magnetic field sensing, particularly due to its unmatched stretching capabilities under magnetic field exposure. Numerous studies have investigated MPC-based magnetic field sensors by subjecting cantilevers to significant magnetic fields in the mT range. These studies detect cantilever bending through methods such as image processing 14 , monitoring shifts in Bragg wavelength via FBG 11,15 , or by performing magnetoimpedance and evaluating electrical resistance changes 16 . While these investigations thoroughly explore the mechanical and magnetic properties of emerging sensor concepts, comparing measurements across different sensors presents challenges due to their diverse characterization methods. It is also crucial to evaluate if the sensor responses are linear with variations in magnetic field strengths. While some literature defines low magnetic fields as those under 1 T 17 , relevant applications like magnetocardiography (MCG) or magnetoencephalography (MEG) require detecting fields as minute as 10 fT, which is more than 10 orders of magnitude smaller. Claims of measuring fields in the mT range down to 0 mT can be misleading, suggesting the ability to detect any magnetic field. For ME sensors Elzenheimer et al. 18 proposed a sophisticated evaluation scheme, which has been applied to the MPC based sensor of this study. Sensors from various categories require consistent evaluation methods to enable meaningful comparisons, even in the field of highly sensitive magnetometers. The sensors can be fabricated in complex shapes by designing molds beforehand, but it is also possible to cut the sensor after the fabrication mechanically or with a laser. The MPC is electrically contacted with a thin nanoscale sculptured aluminum 19 sheet, which is the key for this concept to work. This sculpturing does not affect bulk properties like conductivity but leaves a rough surface with a hook like structure. This allows a stable mechanical connection to the chemically inert silicone. The contacted composite is clamped on one end and oriented parallel to an electret. The electret has quasi-permanent surface charges Q . 20 Both components form a structure, which can be interpreted as a plate capacitor (cf. Eqs. 1 and 2 ). When an AC magnetic field is applied, the MPC begins to oscillate, which alters the distance d between the two components and subsequently the capacity C : $$C = {\epsilon }_{0}{\epsilon }_{r} \bullet \frac{A}{d}$$ 1 $$U = \frac{Q}{C}$$ 2 where ε 0 is the vacuum permittivity, ε r is the relative permittivity, A is the area of the two plates and U is the voltage signal of the sensor. Because the charges are constant, due to the nature of the electret, the voltage signal is only changed by the displacement of the cantilever. In recent studies, researchers have explored a rudimentary form of magnetostrictive polymer composites consisting of two permanent magnets stacked atop one another 21 . The upper magnet is attached to a silicon cantilever with a piezoelectric thin-film layer. When an external magnetic field is applied, it interacts with the magnetic field between the two magnets. This setup provides insight into the particle interaction within the composite. The magnetic interaction among the particles is affected by the external field, resulting in an effect similar to that observed in magnetostrictive materials. In this study, we employed materials that are readily accessible and cost-effective, including silicone (PDMS), carbonyl iron particles and bulk Teflon. The silicone encapsulates the magnetic particles making the cantilever resistant to harsh environmental conditions due to the chemically inertness of PDMS 22 . The silicone used in this work is also biocompatible making it favorable for biomedical applications. Although the sensor performance is not at the state-of-the-art level in terms of sensitivity and limit of detection values, it presents numerous tuning possibilities, and several parameters still need to be optimized. Unlike some other sensors, there is no need for an initialization step to adjust the magnetic domain structure 23 . In contrast to MPC-based sensors, the attained limit of detection of 95.6 nT/√Hz represents a substantial advancement. 24 2 Results As described in section 2.4, the outer frame of the housing of the sensor element is cube like, which gives the option to orient the sensor in the aluminum tube and measure along all three spatial directions. Figure 2 shows the results. By measuring along the cantilever direction, the sensor generates a signal, which shows a pronounced resonant behavior. By rotating the sensor 90° in the x-z-plane the signal is increased by a factor of 10. If the sensor is rotated 90° (from the original position) within the x-y-plane, the signal magnitude is in the same order of magnitude as in the first case. All consequent measurements were performed along the orientation with the highest signal. The magnetic particle concentration has also an impact on the sensitivity as well. It is given in weight percentages (wt.%) and always refers to the amount of iron particles in comparison to the amount of silicone. Four different sensor elements were investigated ranging from 10 wt.% to 70 wt.%. The different resonance frequencies and resulting sensitivity responses are depicted in Fig. 2 . The sensor element containing 10 wt.% iron particles is not able to detect the applied magnetic fields. The given value for the sensitivity is the average of all the data points of the frequency sweep (cf. supplementary figure S1 ). While the 30 wt.% sensor demonstrates the capability to register the applied magnetic field, the resulting signal remains comparatively modest with 4.3 µV and the frequency sweep is dominated by noise. The most substantial signal, measuring 1.15 mV, is generated by the sensor employing a particle concentration of 50 wt.%. However, a further increase of the concentration, up to 70 wt.%, leads to a reduction in the signal magnitude, which diminishes to 0.67 mV. As described in section 2.5, a DC bias field was applied in the range from − 1 mT to 1 mT. This finding verifies that the magnetization of the sensor itself does not change during magnetic measurements. The largest sensor signal is reached at a bias field of -533 µT (cf. supplementary figure S2). Thus, the following measurements were performed with this bias field. As described in section 2.5, a frequency sweep was performed between 80 Hz and 280 Hz, which reveals a mechanical resonance frequency of 160.5 Hz. This is the point where the sensor is most sensitive and thus detects the smallest magnetic fields (cf. Figure 3 ). The equalized spectral noise density has its minimum at the resonance frequency. A higher or lower frequency results in a decrease in the signal-to-noise ratio (SNR), due to the lower sensitivity of the sensor. The quality factor is 8, which leads to a 3-dB bandwidth of approximately 20 Hz. At resonance the sensitivity is 1.96 V/T. The smallest field, detected by the sensor is 95.6 nT. It is misleading to chase for higher and higher sensitivities. This is only favorable if the noise is not increased in the same way. Schoinas et al. reported on a sensor with a high sensitivity of 14620 V/T 25 . The lowest detectable field is at ± 40 µT. Like the sensor presented in this work, it is cantilever based. Even though the sensitivity is four orders of magnitude lower (1.96 V/T), this works sensor is capable of detecting fields that are three orders of magnitude smaller (√95.6 nT/Hz). 3 Discussion The results show that sensor elements require high particle concentrations to have large sensitivities. When the concentration is too low, the particles interact like individual units and do not influence each other due to the large distance between them. With increasing concentration, the particles in the composite are closer together, which increases the interaction between them and thus, the deflection of the cantilever is more pronounced. There seems to be a maximum distortion of the cantilever at around 50 wt.% most likely on the upper side. This gives the opportunity to increase the signal further just by tweaking the particle concentration. At 70 wt.% the amplitude of the signal is already decreased. By increasing the particle concentration, the composite’s stiffness increases, as the mechanical properties of the iron particles become more prominent. An optimal point is reached where the composite contains a sufficient quantity of magnetic particles to induce maximal deformation in the polymer matrix, while avoiding an excessive level that would compromise the flexibility of the matrix. When the sensor element is exposed to a magnetic field, several interactions occur between the particles. The particles act slightly different on the magnetic field, because they are not perfectly aligned, they change their position towards each other and the particles rotate. Among these interactions, particle rotation emerges as the most influential factor, causing significant deformations in the surrounding matrix and consequently leading to substantial cantilever deflection. The orientation of the magnetic active material plays a crucial role and leads to a true vector sensor, which is sensitive in only one direction. The particles are oriented along the long axis, denoted as the x-axis, of the cantilever. When a magnetic field is applied in the x-direction, the particle rotation remains limited, resulting in a relatively weak signal response. Similarly, when measurements are conducted along the y-axis, the signal strength remains comparatively modest. In this scenario, particle rotation is feasible but constrained by the mechanical rigidity of the aluminum contact. The contact exhibits high stiffness, preventing in-plane deformation induced by the rotating particles. When the field is applied in the z-direction the signal increases by a factor of 10. Similar to the case of the y-direction the particles can rotate, leading to an out-of-plane deformation of the aluminum contact that requires considerably less energy. As a result, this leads to a more pronounced deflection, which is directly proportional to the signal amplitude. The bias measurement shows a constant signal for fields larger than ± 600 µT. This can be explained by the strong electrostatic interaction of the sensor components. The electret is negatively charged and creates positive mirror charges at the electrode below the cantilever. When these two components come closer together even more charges are created. Simultaneously the attractive forces between the positive and negative charges increase drastically. The cantilever snaps to the electret and can only move partially due to the strong attractive forces, thus resulting in a smaller signal. 4 Conclusion and Outlook The novel magnetostrictive polymer composite sensor presented in this study offers promising possibilities for magnetic field detection. By employing silicone as the polymeric matrix and integrating ferromagnetic iron particles, this sensor demonstrates tunability in mechanical and magnetic properties, providing a versatile platform for optimization. The MPC is effectively contacted using nanoscale sculptured aluminum, ensuring a robust and reliable electrical connection and utilizes an electret, which provides a permanent electric field for the read-out. The sensor's resonance frequency, at 160.5 Hz, offers sensitivity to small magnetic fields, with a limit of detection as low as 95.6 nT. This is a big improvement compared to the existing composite-based and electret-based sensors, resulting in a. Its 3-dB bandwidth of 20 Hz and quality factor of 8 suggest a small but sensitive frequency range. Increasing the particle concentration to around 50 wt.% leads to a higher sensitivity. The sensor element has a predominant direction making it suitable for detecting the direction of a magnetic field by combining several elements. It can also reduce directional magnetic noise, by orienting it unfavorable for the noise. The sensor is built by broadly available materials such as silicone, iron, PTFE and aluminum. The manufacturing process is straightforward and allows a tremendous number of tuning possibilities before, during and after the sensor element preparation. By choosing silicone as polymer, the sensor can withstand harsh environmental conditions and is biocompatible. Future improvements may involve the substitution of iron particles with harder magnetic materials, such as Neodymium-Iron-Boron alloys, to reduce noise originating from the magnetic component. Optimization of the aluminum contact and exploration of different geometries could further enhance the sensitivity. 5 Methods 5.1 Magnetostrictive polymer composite fabrication The magnetostrictive polymer composite was fabricated using two-component silicone (Ecoflex 00–30, Smooth-On, PDMS, 20 g). The components were mixed with carbonyl iron particles (Sigma, diameter: 20–100 µm, 20 g) in a paper cup. During the mixing process, air entered the mixture and was removed by subjecting the dispersion to a low-pressure environment in a custom-built desiccator connected to a scroll pump. The pressure was reduced to 1 mbar within the first 30 seconds and was maintained for an additional 5 minutes to eliminate air bubbles from the composite. Subsequently, the desiccator was flooded with air until ambient pressure was reached. The MPC fabrication involved the use of a nanoscale sculptured aluminum sheet (cf. Chapter 2.2) with a thickness of 100 µm as the bottom layer, with the sculptured surface facing upwards, in a 3D-printed polylactic acid (PLA) mold with an inner diameter of 25 mm × 25 mm × 1 mm. The liquid MPC was poured on top of the aluminum sheet and a polymethyl methacrylate (PMMA) plate was placed on top of it to eliminate excess composite and create a smooth, flat surface. While the silicone is liquid, it fills the cavities of the aluminum. The silicone started to become viscous after 30 minutes and fully cured after 4 hours at room temperature. To orient the particles the curing takes place in a magnetic DC field of 100 mT. Due to the hook like structure, the cured MPC is mechanically connected to the aluminum, which serves as the read-out electrode of the sensor. The high viscosity of the MPC prevented the iron particles from fully sedimenting, and the composite can be cut into various shapes using mechanical or laser cutting techniques after curing. 5.2 Electrical contact The establishment of a reliable electrical contact with the MPC presents certain challenges, primarily attributed to the intrinsic properties of silicone. In an initial attempt, the application of silver glue from Acheson, specifically Silver DAG 1415, was explored using a brush. While this approach initially facilitated wetting of the MPC, it caused issues such as delamination during the drying process and deformation of the composite. Subsequently, a 200 nm-thick gold film was investigated, which was deposited through physical vapor deposition. However, this method proved to be less conductive than desired, potentially due to the rough surface topography arising from the 3D printed molds used in the fabrication process. To establish a contact that is both reliable and durable, nanoscale sculptured aluminum was considered. In this approach, 100 µm-thick aluminum sheets underwent an etching process employing hydrochloric acid (HCl) from one side. The HCl solution was prepared at a concentration of 7.25 wt.%, and etching was carried out at room temperature without stirring. This procedure yielded a distinctive hook-like structure comprised of cuboids, oriented at 90° angles to each other. This etching technique exhibited no preferential grain boundary dissolution, but it is defined by the crystallographic orientation of the grains. Specifically, the {100} plane is more stable, resulting in flat surfaces at both nanometer and micrometer scales 19 . 5.3 Electret fabrication The electrets utilized in the current sensors are made from 1 mm thick bulk Polytetrafluoroethylene (PTFE or Teflon) with dimensions of 12 mm × 12 mm, which were obtained from a larger sheet. A self-built corona discharge setup 20 was utilized to impart surface charges on the PTFE. The setup consisted of a metal sheet serving as the ground electrode, with the PTFE placed atop it and a wire serving as the discharge electrode. A voltage of 5 kV was applied for 1 minute. It is important to allow the electret to rest for at least one day prior to use in the sensor to ensure that any shallow charges that may contribute to sensor noise and negatively impact the limit of detection have dissipated. 5.4 Sensor assembly The sensor housing (cf. Figure 1 ) was fabricated using a “Form 2” 3D printer from Formlabs. The Clear V4 resin was used and the part was printed at a resolution of 50 micrometers. The cube-shaped design features clamps for securing the electret on the bottom and the cantilever on the top, with the option of using a double-clamped cantilever for various excitation modes. Its size and shape allow for insertion into a coil pair used to generate magnetic fields for the measurements, but it cannot rotate once inserted. Measurements along all three directions in space can be performed. A copper sheet with a cable soldered to it is attached to the cube, serving as the sensing contact for picking up the generated signal by the MPC. A separate copper contact is positioned near the MPC and used as a reference, enabling differential sensor readout, and reducing overall noise. 5.5 Magnetic field measurements The magnetic field measurements were performed with a custom-made setup, which is placed on a vibration-proof table. A coil pair is used to generate AC and DC magnetic fields. The DC-coil has approximately 1500 windings and is used to generate a magnetic bias field to operate the sensor at the optimal working point. The AC-coil has around 750 windings and creates the desired AC magnetic field, which can be detected by the sensor. Both coils have a length of 15 cm. Everything is in a metal box to shield the sensor from electrical noise coming from the environment. In addition, a thin aluminum tube is inserted into the coils for additional electrical shielding. Both parts are connected to the ground. The coils are wrapped in 5 isolated layers of Mu-Metal with a thickness of 300 µm to shield the sensor from magnetic noise. The sensor has a mechanical resonance frequency at which it is most sensitive. This is determined by a sinusoidal frequency sweep in steps of 2 Hz, followed by a high-resolution measurement to determine the exact frequency 18 . During these measurements, a constant field strength of 100 µT is used. Next, a DC bias field measurement is conducted. This involves applying a constant AC field with a frequency matching to the resonance frequency of the sensor, with an amplitude of 100 µT. A DC field ranging from − 1 mT to 1 mT is then applied in both directions, in order to ensure that the magnetization of the sensor remains unchanged. The optimum working point is identified as the point at which the sensor produces the highest signal. Finally, the smallest detectable field is determined through a series of measurements in which the sensor is operated under ideal bias field conditions and in resonance. During each measurement, the AC magnetic field is gradually reduced. At one point, the generated AC magnetic field reaches the sensor’s noise level. At a certain point, the generated AC magnetic field approaches the sensor’s noise level. At this juncture, the noise power produced by the sensor surpasses the signal power of the generated magnetic field. Declarations Acknowledgement This work was supported by the German Research Foundation (Deutsche Forschungsgemeinschaft, DFG) under project 286471992 (Collaborative Research Centre 1261, “Magnetoelectric Sensors: From Composite Materials to Biomagnetic Diagnostics”). Additional Information DECLARATION OF COMPETING INTERESTS The authors declare that they have no known competing financial interests or personal relationships that could have influenced the work reported in this paper. Data Availability: All relevant data are available from the corresponding author Rainer Adelung, [email protected] upon reasonable request. Any additional information required to replicate the results of this study is also available from the corresponding author upon reasonable request. Author contribution statement Lukas Zimoch 1 : Prepared draft, sample preparation, measurements, data evaluation, figure preparation Stefan Schröder 2 : sample preparation, scientific discussion Eric Elzenheimer 3, 4 : Measurements, data evaluation, proofreading Sören Kaps 1 : Supervision, scientific discussion, proofreading Thomas Strunskus 2 : Scientific discussion, proofreading Franz Faupel 2 : Acquisition, scientific discussion, proofreading Michael Höft 3 : Acquisition, scientific discussion, proofreading Rainer Adelung *, 1 : Acquisition, supervision, scientific discussion, proofreading References Melzer, M., Makarov, D. & Schmidt, O. G. A review on stretchable magnetic field sensorics. J. Phys. D: Appl. Phys. 53, 83002; 10.1088/1361-6463/ab52cf (2020). Fagaly, R. L. Superconducting quantum interference device instruments and applications. Review of Scientific Instruments 77 ; 10.1063/1.2354545 (2006). Sternickel, K. & Braginski, A. I. Biomagnetism using SQUIDs: status and perspectives. Supercond. Sci. Technol. 19, S160-S171; 10.1088/0953-2048/19/3/024 (2006). Annapureddy, V. et al. A pT/√Hz sensitivity ac magnetic field sensor based on magnetoelectric composites using low-loss piezoelectric single crystals. Sensors and Actuators A: Physical 260, 206–211; 10.1016/j.sna.2017.04.017 (2017). Xi, H. et al. A Room Temperature Ultrasensitive Magnetoelectric Susceptometer for Quantitative Tissue Iron Detection. Scientific reports 6, 29740; 10.1038/srep29740 (2016). Boto, E. et al. A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers. NeuroImage 149, 404–414; 10.1016/j.neuroimage.2017.01.034 (2017). Zhang, R. et al. Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers. Applied Physics ; 10.1126/sciadv.aba8792 (2020). Murzin, D. et al. Ultrasensitive Magnetic Field Sensors for Biomedical Applications. Sensors (Basel, Switzerland) 20 ; 10.3390/s20061569 (2020). Elzenheimer, E. et al. Investigation of Converse Magnetoelectric Thin-Film Sensors for Magnetocardiography. IEEE Sensors J. 23, 5660–5669; 10.1109/JSEN.2023.3237910 (2023). Piorra, A. et al. Magnetoelectric thin film composites with interdigital electrodes. Applied Physics Letters 103 ; 10.1063/1.4812706 (2013). Liu, H., Or, S. W. & Tam, H. Y. Magnetostrictive composite–fiber Bragg grating (MC–FBG) magnetic field sensor. Sensors and Actuators A: Physical 173, 122–126; 10.1016/j.sna.2011.11.005 (2012). Chen, J., Huang, S.-Y., Lin, C.-Y. & Liu, W.-F. A Low-Frequency Magnetic Field Sensor Based on Fiber Bragg Gratings. Photonics 9, 102; 10.3390/photonics9020102 (2022). Mintken, M. et al. Nanogenerator and piezotronic inspired concepts for energy efficient magnetic field sensors. Nano Energy 56, 420–425; 10.1016/j.nanoen.2018.11.031 (2019). Glavan, G., Belyaeva, I. A., Ruwisch, K., Wollschläger, J. & Shamonin, M. Magnetoelectric Response of Laminated Cantilevers Comprising a Magnetoactive Elastomer and a Piezoelectric Polymer, in Pulsed Uniform Magnetic Fields. Sensors (Basel, Switzerland) 21 ; 10.3390/s21196390 (2021). Liu, C. et al. Multiparameter sensor based on micro/nano-structured optical fiber and composites. Heliyon 8, e10941; 10.1016/j.heliyon.2022.e10941 (2022). Hu, T., Xuan, S., Ding, L. & Gong, X. Liquid metal circuit based magnetoresistive strain sensor with discriminating magnetic and mechanical sensitivity. Sensors and Actuators B: Chemical 314, 128095; 10.1016/j.snb.2020.128095 (2020). Norhaniza, R. et al. Enhancement of sensitivity of magnetostrictive foam in low magnetic fields for sensor applications. Polymer 211, 123083; 10.1016/j.polymer.2020.123083 (2020). Elzenheimer, E. et al. Quantitative Evaluation for Magnetoelectric Sensor Systems in Biomagnetic Diagnostics. Sensors (Basel, Switzerland) 22 ; 10.3390/s22031018 (2022). Baytekin-Gerngross, M., Gerngross, M. D., Carstensen, J. & Adelung, R. Making metal surfaces strong, resistant, and multifunctional by nanoscale-sculpturing. Nanoscale horizons 1, 467–472; 10.1039/c6nh00140h (2016). Schröder, S., Strunskus, T., Rehders, S., Gleason, K. K. & Faupel, F. Tunable polytetrafluoroethylene electret films with extraordinary charge stability synthesized by initiated chemical vapor deposition for organic electronics applications. Scientific reports 9, 2237; 10.1038/s41598-018-38390-w (2019). Gerhardt, M. et al. Self-powered elementary hybrid magnetoelectric sensor. Nano Energy 115, 108720; 10.1016/j.nanoen.2023.108720 (2023). LeVier_WHAT IS SILICONE_1995. Baumann, J., Göger, D. & Kiencke, U. A MAGNETO-ELASTIC SENSOR FOR MEASURING PRESSURE OSCILLATIONS IN COMMON RAIL SYSTEMS. IFAC Proceedings Volumes 38, 67–72; 10.3182/20050703-6-CZ-1902.01899 (2005). Zhou, Y. et al. Enhanced non-bias-field magnetoelectric response with high detectivity in a sensing system based on electret film and magnetostrictive material. Measurement 207, 112365; 10.1016/j.measurement.2022.112365 (2023). Schoinas, S., El Guamra, A.-M., Moreillon, F. & Passeraub, P. Fabrication and Characterization of a Flexible Fluxgate Sensor with Pad-Printed Solenoid Coils. Sensors (Basel, Switzerland) 20 ; 10.3390/s20082275 (2020). Additional Declarations No competing interests reported. Supplementary Files Supplementarysr.docx Cite Share Download PDF Status: Published Journal Publication published 10 Jan, 2025 Read the published version in Scientific Reports → Version 1 posted Editorial decision: Revision requested 09 Oct, 2024 Reviews received at journal 07 Oct, 2024 Reviewers agreed at journal 04 Sep, 2024 Reviewers agreed at journal 13 Jul, 2024 Reviews received at journal 12 Jul, 2024 Reviewers agreed at journal 09 Jul, 2024 Reviewers invited by journal 24 Jun, 2024 Editor assigned by journal 24 Jun, 2024 Editor invited by journal 21 Jun, 2024 Submission checks completed at journal 19 Jun, 2024 First submitted to journal 18 Jun, 2024 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-4600004","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Article","associatedPublications":[],"authors":[{"id":319644191,"identity":"e6b47e35-5404-41ef-9d79-6b11a14b3781","order_by":0,"name":"Lukas Zimoch","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAA1klEQVRIie3OPwqDMBTH8RcKujx0tVA8w4MuHWzPEhF0EdojBDp08QAewyMouYTQDpaCs6MFoY2lf7bo2CFfCAHxwy8AJtMf5qhTduCriwkmCFYAXE8sdaqcr78EZ5EFvsiIYA7xkqvc9gR0PgqWHwIEOyonCOcy5YpcKsEKihGw1c8oUioyANXh6d6QRPBSmiChkJtxpQ4Fa+ihyL6bIBFI+JCCynFFK8DCFqosJlyOJKcI1Rf9w1w7uXV9QL5TJw3Lhp3v2lGjn3mHv91Z/5tMJpNJ2xMu/j/3gfaNZAAAAABJRU5ErkJggg==","orcid":"","institution":"Kiel University","correspondingAuthor":true,"prefix":"","firstName":"Lukas","middleName":"","lastName":"Zimoch","suffix":""},{"id":319644192,"identity":"df1e38b7-e5c6-4664-9886-f9caa5049d6b","order_by":1,"name":"Stefan Schröder","email":"","orcid":"","institution":"Kiel University","correspondingAuthor":false,"prefix":"","firstName":"Stefan","middleName":"","lastName":"Schröder","suffix":""},{"id":319644193,"identity":"d1008bdb-2554-4318-88da-ebd235bc75d2","order_by":2,"name":"Eric Elzenheimer","email":"","orcid":"","institution":"Kiel University","correspondingAuthor":false,"prefix":"","firstName":"Eric","middleName":"","lastName":"Elzenheimer","suffix":""},{"id":319644194,"identity":"d26d6f00-9e74-47d2-9015-cd22932dd24f","order_by":3,"name":"Sören Kaps","email":"","orcid":"","institution":"Kiel University","correspondingAuthor":false,"prefix":"","firstName":"Sören","middleName":"","lastName":"Kaps","suffix":""},{"id":319644195,"identity":"583051a6-7aa1-4eb9-8f59-5f8d186290e9","order_by":4,"name":"Thomas Strunskus","email":"","orcid":"","institution":"Kiel University","correspondingAuthor":false,"prefix":"","firstName":"Thomas","middleName":"","lastName":"Strunskus","suffix":""},{"id":319644196,"identity":"549724ec-97e1-4df1-a6e3-7fe6af3cdd2f","order_by":5,"name":"Franz Faupel","email":"","orcid":"","institution":"Kiel University","correspondingAuthor":false,"prefix":"","firstName":"Franz","middleName":"","lastName":"Faupel","suffix":""},{"id":319644197,"identity":"68b9b30a-8e4f-4f5d-9047-d2d03ae2dc3e","order_by":6,"name":"Michael Höft","email":"","orcid":"","institution":"Kiel University","correspondingAuthor":false,"prefix":"","firstName":"Michael","middleName":"","lastName":"Höft","suffix":""},{"id":319644198,"identity":"9941b283-2d38-4837-ab8f-0fd29d32e062","order_by":7,"name":"Rainer Adelung","email":"","orcid":"","institution":"Kiel University","correspondingAuthor":false,"prefix":"","firstName":"Rainer","middleName":"","lastName":"Adelung","suffix":""}],"badges":[],"createdAt":"2024-06-18 12:33:18","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-4600004/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-4600004/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1038/s41598-024-85069-6","type":"published","date":"2025-01-10T15:58:07+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":59705105,"identity":"e0355865-67a1-45b5-a5c0-61c616f1d9e9","added_by":"auto","created_at":"2024-07-05 05:45:14","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":65753,"visible":true,"origin":"","legend":"\u003cp\u003eVector behavior and influence of particle concentration.\u003c/p\u003e","description":"","filename":"floatimage1.png","url":"https://assets-eu.researchsquare.com/files/rs-4600004/v1/a4dc6ed24e2d42213c0d0b7a.png"},{"id":59705568,"identity":"af6d9baa-e7a6-4810-92c7-0eb0a4b614f1","added_by":"auto","created_at":"2024-07-05 05:53:14","extension":"png","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":228247,"visible":true,"origin":"","legend":"\u003cp\u003ePerformance of the sensor with 50 wt.% iron particles.\u003c/p\u003e","description":"","filename":"floatimage2.png","url":"https://assets-eu.researchsquare.com/files/rs-4600004/v1/cec3a01970adc74b5ff54e35.png"},{"id":59705107,"identity":"66cdf598-7fea-4b76-a73a-6226b9ef264c","added_by":"auto","created_at":"2024-07-05 05:45:14","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":820360,"visible":true,"origin":"","legend":"\u003cp\u003eAssembled sensor with details.\u003c/p\u003e","description":"","filename":"floatimage3.png","url":"https://assets-eu.researchsquare.com/files/rs-4600004/v1/c9cd2e548abbef0c8e9f11c4.png"},{"id":73694113,"identity":"558f7344-e118-44c2-82c2-9f96e6cba498","added_by":"auto","created_at":"2025-01-13 16:11:08","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":1848416,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-4600004/v1/42cccd9a-c1cb-4b2e-a2ba-f0c9f5129bc3.pdf"},{"id":59705106,"identity":"a0eef0ec-981f-44c2-ac8c-eee32f92b508","added_by":"auto","created_at":"2024-07-05 05:45:14","extension":"docx","order_by":1,"title":"","display":"","copyAsset":false,"role":"supplement","size":72144,"visible":true,"origin":"","legend":"","description":"","filename":"Supplementarysr.docx","url":"https://assets-eu.researchsquare.com/files/rs-4600004/v1/a4e55c66a9b8add8bf5a11c1.docx"}],"financialInterests":"No competing interests reported.","formattedTitle":"Electret Integrated Magnetic Field Sensor Based on Magnetostrictive Polymer Composite with nT Resolution","fulltext":[{"header":"1 Introduction","content":"\u003cp\u003eThe market for magnetoelectric field sensors is experiencing growth due to increasing demand in various industries, such as the automotive sector and especially in biomedical applications for systems with navigation, orientation, and motion tracking. However, they can also be utilized for electronic skins, smart textiles, soft robotics and actuators \u003csup\u003e1\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eThe most advanced sensors that are capable of detecting magnetic signals as small as the signals of the human brain are superconducting quantum interference devices (SQUIDs). \u003csup\u003e2,3\u003c/sup\u003e Due to their bulky size and requirement for cryogenic cooling, they result in significant costs, making their widespread use challenging \u003csup\u003e4,5\u003c/sup\u003e. An alternative to SQUIDs are optically pumped magnetometers (OPMs), which achieve performances similar to those of SQUIDs without the need for cryogenic cooling \u003csup\u003e6,7\u003c/sup\u003e. Sensor such as fluxgate magnetometers or Hall effect sensors are limited by magnetic noise and their sensitivity cannot be reduced further \u003csup\u003e8\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eAnother common approach for magnetoelectric field sensors is to utilize a combination of a magnetostrictive material, which is sensitive to magnetic fields, and a mechanically linked piezoelectric material, which generates an electrical signal proportional to the magnetic field of interest. These sensors are usually referred as Magnetoelectric (ME) sensors \u003csup\u003e9,10\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eAn alternative method involves the integration of a fiber Bragg grating (FBG) with a magnetostrictive cantilever. The deformation of the FBG modifies its reflection spectrum, which can be related to the magnetic signal \u003csup\u003e11,12\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eCantilever-based sensors face limitations in adjusting mechanical properties independently from the magnetic properties. Cantilever-based sensors have the drawback, that it is not easy to freely change the mechanical properties without changing the magnetic properties. Attempts were undertaken by utilizing an electret to manipulate the resonance frequency of the cantilever resulting in an undamping, which can be related to the electrostatic interactions \u003csup\u003e13\u003c/sup\u003e. The sensor presented in this work uses a magnetostrictive polymer composite, which consists of ferromagnetic particles embedded in a polymer matrix. The mechanical properties are defined by the matrix material, which can be tuned or totally replaced by a different polymer. This gives the opportunity to change the resonance frequency of the sensor without changing the geometry, or to protect the magnetic particles from environmental conditions such as corrosion. On the other hand, the type or number of magnetic particles can be changed. This metamaterial emerges as a compelling candidate for magnetic field sensing, particularly due to its unmatched stretching capabilities under magnetic field exposure.\u003c/p\u003e \u003cp\u003eNumerous studies have investigated MPC-based magnetic field sensors by subjecting cantilevers to significant magnetic fields in the mT range. These studies detect cantilever bending through methods such as image processing \u003csup\u003e14\u003c/sup\u003e, monitoring shifts in Bragg wavelength via FBG \u003csup\u003e11,15\u003c/sup\u003e, or by performing magnetoimpedance and evaluating electrical resistance changes \u003csup\u003e16\u003c/sup\u003e.\u003c/p\u003e \u003cp\u003eWhile these investigations thoroughly explore the mechanical and magnetic properties of emerging sensor concepts, comparing measurements across different sensors presents challenges due to their diverse characterization methods. It is also crucial to evaluate if the sensor responses are linear with variations in magnetic field strengths. While some literature defines low magnetic fields as those under 1 T \u003csup\u003e17\u003c/sup\u003e, relevant applications like magnetocardiography (MCG) or magnetoencephalography (MEG) require detecting fields as minute as 10 fT, which is more than 10 orders of magnitude smaller. Claims of measuring fields in the mT range down to 0 mT can be misleading, suggesting the ability to detect any magnetic field. For ME sensors Elzenheimer et al. \u003csup\u003e18\u003c/sup\u003e proposed a sophisticated evaluation scheme, which has been applied to the MPC based sensor of this study. Sensors from various categories require consistent evaluation methods to enable meaningful comparisons, even in the field of highly sensitive magnetometers.\u003c/p\u003e \u003cp\u003eThe sensors can be fabricated in complex shapes by designing molds beforehand, but it is also possible to cut the sensor after the fabrication mechanically or with a laser.\u003c/p\u003e \u003cp\u003eThe MPC is electrically contacted with a thin nanoscale sculptured aluminum \u003csup\u003e19\u003c/sup\u003e sheet, which is the key for this concept to work. This sculpturing does not affect bulk properties like conductivity but leaves a rough surface with a hook like structure. This allows a stable mechanical connection to the chemically inert silicone. The contacted composite is clamped on one end and oriented parallel to an electret. The electret has quasi-permanent surface charges \u003cem\u003eQ\u003c/em\u003e. \u003csup\u003e20\u003c/sup\u003e Both components form a structure, which can be interpreted as a plate capacitor (cf. Eqs.\u0026nbsp;\u003cspan refid=\"Equ1\" class=\"InternalRef\"\u003e1\u003c/span\u003e and \u003cspan refid=\"Equ2\" class=\"InternalRef\"\u003e2\u003c/span\u003e). When an AC magnetic field is applied, the MPC begins to oscillate, which alters the distance \u003cem\u003ed\u003c/em\u003e between the two components and subsequently the capacity \u003cem\u003eC\u003c/em\u003e:\u003cdiv id=\"Equ1\" class=\"Equation\"\u003e\u003cdiv format=\"TEX\" class=\"mathdisplay\" id=\"FileID_Equ1\" name=\"EquationSource\"\u003e\n$$C = {\\epsilon }_{0}{\\epsilon }_{r} \\bullet \\frac{A}{d}$$\u003c/div\u003e\u003cdiv class=\"EquationNumber\"\u003e1\u003c/div\u003e\u003c/div\u003e\u003cdiv id=\"Equ2\" class=\"Equation\"\u003e\u003cdiv format=\"TEX\" class=\"mathdisplay\" id=\"FileID_Equ2\" name=\"EquationSource\"\u003e\n$$U = \\frac{Q}{C}$$\u003c/div\u003e\u003cdiv class=\"EquationNumber\"\u003e2\u003c/div\u003e\u003c/div\u003e\u003c/p\u003e \u003cp\u003ewhere ε\u003csub\u003e0\u003c/sub\u003e is the vacuum permittivity, ε\u003csub\u003er\u003c/sub\u003e is the relative permittivity, A is the area of the two plates and U is the voltage signal of the sensor. Because the charges are constant, due to the nature of the electret, the voltage signal is only changed by the displacement of the cantilever. In recent studies, researchers have explored a rudimentary form of magnetostrictive polymer composites consisting of two permanent magnets stacked atop one another \u003csup\u003e21\u003c/sup\u003e. The upper magnet is attached to a silicon cantilever with a piezoelectric thin-film layer. When an external magnetic field is applied, it interacts with the magnetic field between the two magnets. This setup provides insight into the particle interaction within the composite. The magnetic interaction among the particles is affected by the external field, resulting in an effect similar to that observed in magnetostrictive materials.\u003c/p\u003e \u003cp\u003eIn this study, we employed materials that are readily accessible and cost-effective, including silicone (PDMS), carbonyl iron particles and bulk Teflon. The silicone encapsulates the magnetic particles making the cantilever resistant to harsh environmental conditions due to the chemically inertness of PDMS \u003csup\u003e22\u003c/sup\u003e. The silicone used in this work is also biocompatible making it favorable for biomedical applications.\u003c/p\u003e \u003cp\u003eAlthough the sensor performance is not at the state-of-the-art level in terms of sensitivity and limit of detection values, it presents numerous tuning possibilities, and several parameters still need to be optimized. Unlike some other sensors, there is no need for an initialization step to adjust the magnetic domain structure \u003csup\u003e23\u003c/sup\u003e. In contrast to MPC-based sensors, the attained limit of detection of 95.6 nT/\u0026radic;Hz represents a substantial advancement.\u003csup\u003e24\u003c/sup\u003e\u003c/p\u003e"},{"header":"2 Results","content":"\u003cp\u003eAs described in section 2.4, the outer frame of the housing of the sensor element is cube like, which gives the option to orient the sensor in the aluminum tube and measure along all three spatial directions. Figure\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e2\u003c/span\u003e shows the results. By measuring along the cantilever direction, the sensor generates a signal, which shows a pronounced resonant behavior. By rotating the sensor 90\u0026deg; in the x-z-plane the signal is increased by a factor of 10. If the sensor is rotated 90\u0026deg; (from the original position) within the x-y-plane, the signal magnitude is in the same order of magnitude as in the first case. All consequent measurements were performed along the orientation with the highest signal.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eThe magnetic particle concentration has also an impact on the sensitivity as well. It is given in weight percentages (wt.%) and always refers to the amount of iron particles in comparison to the amount of silicone. Four different sensor elements were investigated ranging from 10 wt.% to 70 wt.%. The different resonance frequencies and resulting sensitivity responses are depicted in Fig.\u0026nbsp;\u003cspan refid=\"Fig3\" class=\"InternalRef\"\u003e2\u003c/span\u003e. The sensor element containing 10 wt.% iron particles is not able to detect the applied magnetic fields. The given value for the sensitivity is the average of all the data points of the frequency sweep (cf. supplementary figure \u003cspan refid=\"MOESM1\" class=\"InternalRef\"\u003eS1\u003c/span\u003e). While the 30 wt.% sensor demonstrates the capability to register the applied magnetic field, the resulting signal remains comparatively modest with 4.3 \u0026micro;V and the frequency sweep is dominated by noise. The most substantial signal, measuring 1.15 mV, is generated by the sensor employing a particle concentration of 50 wt.%. However, a further increase of the concentration, up to 70 wt.%, leads to a reduction in the signal magnitude, which diminishes to 0.67 mV.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eAs described in section 2.5, a DC bias field was applied in the range from \u0026minus;\u0026thinsp;1 mT to 1 mT. This finding verifies that the magnetization of the sensor itself does not change during magnetic measurements. The largest sensor signal is reached at a bias field of -533 \u0026micro;T (cf. supplementary figure S2). Thus, the following measurements were performed with this bias field.\u003c/p\u003e \u003cp\u003eAs described in section 2.5, a frequency sweep was performed between 80 Hz and 280 Hz, which reveals a mechanical resonance frequency of 160.5 Hz. This is the point where the sensor is most sensitive and thus detects the smallest magnetic fields (cf. Figure\u0026nbsp;\u003cspan refid=\"Fig5\" class=\"InternalRef\"\u003e3\u003c/span\u003e). The equalized spectral noise density has its minimum at the resonance frequency. A higher or lower frequency results in a decrease in the signal-to-noise ratio (SNR), due to the lower sensitivity of the sensor. The quality factor is 8, which leads to a 3-dB bandwidth of approximately 20 Hz. At resonance the sensitivity is 1.96 V/T. The smallest field, detected by the sensor is 95.6 nT.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003eIt is misleading to chase for higher and higher sensitivities. This is only favorable if the noise is not increased in the same way. Schoinas et al. reported on a sensor with a high sensitivity of 14620 V/T \u003csup\u003e25\u003c/sup\u003e. The lowest detectable field is at \u0026plusmn;\u0026thinsp;40 \u0026micro;T. Like the sensor presented in this work, it is cantilever based. Even though the sensitivity is four orders of magnitude lower (1.96 V/T), this works sensor is capable of detecting fields that are three orders of magnitude smaller (\u0026radic;95.6 nT/Hz).\u003c/p\u003e"},{"header":"3 Discussion","content":"\u003cp\u003eThe results show that sensor elements require high particle concentrations to have large sensitivities. When the concentration is too low, the particles interact like individual units and do not influence each other due to the large distance between them. With increasing concentration, the particles in the composite are closer together, which increases the interaction between them and thus, the deflection of the cantilever is more pronounced. There seems to be a maximum distortion of the cantilever at around 50 wt.% most likely on the upper side. This gives the opportunity to increase the signal further just by tweaking the particle concentration. At 70 wt.% the amplitude of the signal is already decreased. By increasing the particle concentration, the composite\u0026rsquo;s stiffness increases, as the mechanical properties of the iron particles become more prominent. An optimal point is reached where the composite contains a sufficient quantity of magnetic particles to induce maximal deformation in the polymer matrix, while avoiding an excessive level that would compromise the flexibility of the matrix.\u003c/p\u003e \u003cp\u003eWhen the sensor element is exposed to a magnetic field, several interactions occur between the particles. The particles act slightly different on the magnetic field, because they are not perfectly aligned, they change their position towards each other and the particles rotate. Among these interactions, particle rotation emerges as the most influential factor, causing significant deformations in the surrounding matrix and consequently leading to substantial cantilever deflection. The orientation of the magnetic active material plays a crucial role and leads to a true vector sensor, which is sensitive in only one direction. The particles are oriented along the long axis, denoted as the x-axis, of the cantilever. When a magnetic field is applied in the x-direction, the particle rotation remains limited, resulting in a relatively weak signal response. Similarly, when measurements are conducted along the y-axis, the signal strength remains comparatively modest. In this scenario, particle rotation is feasible but constrained by the mechanical rigidity of the aluminum contact. The contact exhibits high stiffness, preventing in-plane deformation induced by the rotating particles. When the field is applied in the z-direction the signal increases by a factor of 10. Similar to the case of the y-direction the particles can rotate, leading to an out-of-plane deformation of the aluminum contact that requires considerably less energy. As a result, this leads to a more pronounced deflection, which is directly proportional to the signal amplitude.\u003c/p\u003e \u003cp\u003eThe bias measurement shows a constant signal for fields larger than \u0026plusmn;\u0026thinsp;600 \u0026micro;T. This can be explained by the strong electrostatic interaction of the sensor components. The electret is negatively charged and creates positive mirror charges at the electrode below the cantilever. When these two components come closer together even more charges are created. Simultaneously the attractive forces between the positive and negative charges increase drastically. The cantilever snaps to the electret and can only move partially due to the strong attractive forces, thus resulting in a smaller signal.\u003c/p\u003e"},{"header":"4 Conclusion and Outlook","content":"\u003cp\u003eThe novel magnetostrictive polymer composite sensor presented in this study offers promising possibilities for magnetic field detection. By employing silicone as the polymeric matrix and integrating ferromagnetic iron particles, this sensor demonstrates tunability in mechanical and magnetic properties, providing a versatile platform for optimization. The MPC is effectively contacted using nanoscale sculptured aluminum, ensuring a robust and reliable electrical connection and utilizes an electret, which provides a permanent electric field for the read-out.\u003c/p\u003e \u003cp\u003eThe sensor's resonance frequency, at 160.5 Hz, offers sensitivity to small magnetic fields, with a limit of detection as low as 95.6 nT. This is a big improvement compared to the existing composite-based and electret-based sensors, resulting in a. Its 3-dB bandwidth of 20 Hz and quality factor of 8 suggest a small but sensitive frequency range.\u003c/p\u003e \u003cp\u003eIncreasing the particle concentration to around 50 wt.% leads to a higher sensitivity. The sensor element has a predominant direction making it suitable for detecting the direction of a magnetic field by combining several elements. It can also reduce directional magnetic noise, by orienting it unfavorable for the noise. The sensor is built by broadly available materials such as silicone, iron, PTFE and aluminum. The manufacturing process is straightforward and allows a tremendous number of tuning possibilities before, during and after the sensor element preparation. By choosing silicone as polymer, the sensor can withstand harsh environmental conditions and is biocompatible.\u003c/p\u003e \u003cp\u003eFuture improvements may involve the substitution of iron particles with harder magnetic materials, such as Neodymium-Iron-Boron alloys, to reduce noise originating from the magnetic component. Optimization of the aluminum contact and exploration of different geometries could further enhance the sensitivity.\u003c/p\u003e"},{"header":"5 Methods","content":"\u003cdiv id=\"Sec6\" class=\"Section2\"\u003e \u003ch2\u003e5.1 Magnetostrictive polymer composite fabrication\u003c/h2\u003e \u003cp\u003eThe magnetostrictive polymer composite was fabricated using two-component silicone (Ecoflex 00\u0026ndash;30, Smooth-On, PDMS, 20 g). The components were mixed with carbonyl iron particles (Sigma, diameter: 20\u0026ndash;100 \u0026micro;m, 20 g) in a paper cup. During the mixing process, air entered the mixture and was removed by subjecting the dispersion to a low-pressure environment in a custom-built desiccator connected to a scroll pump. The pressure was reduced to 1 mbar within the first 30 seconds and was maintained for an additional 5 minutes to eliminate air bubbles from the composite. Subsequently, the desiccator was flooded with air until ambient pressure was reached.\u003c/p\u003e \u003cp\u003eThe MPC fabrication involved the use of a nanoscale sculptured aluminum sheet (cf. Chapter\u0026nbsp;2.2) with a thickness of 100 \u0026micro;m as the bottom layer, with the sculptured surface facing upwards, in a 3D-printed polylactic acid (PLA) mold with an inner diameter of 25 mm \u0026times; 25 mm \u0026times; 1 mm. The liquid MPC was poured on top of the aluminum sheet and a polymethyl methacrylate (PMMA) plate was placed on top of it to eliminate excess composite and create a smooth, flat surface. While the silicone is liquid, it fills the cavities of the aluminum. The silicone started to become viscous after 30 minutes and fully cured after 4 hours at room temperature. To orient the particles the curing takes place in a magnetic DC field of 100 mT.\u003c/p\u003e \u003cp\u003eDue to the hook like structure, the cured MPC is mechanically connected to the aluminum, which serves as the read-out electrode of the sensor. The high viscosity of the MPC prevented the iron particles from fully sedimenting, and the composite can be cut into various shapes using mechanical or laser cutting techniques after curing.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec7\" class=\"Section2\"\u003e \u003ch2\u003e5.2 Electrical contact\u003c/h2\u003e \u003cp\u003eThe establishment of a reliable electrical contact with the MPC presents certain challenges, primarily attributed to the intrinsic properties of silicone. In an initial attempt, the application of silver glue from Acheson, specifically Silver DAG 1415, was explored using a brush. While this approach initially facilitated wetting of the MPC, it caused issues such as delamination during the drying process and deformation of the composite. Subsequently, a 200 nm-thick gold film was investigated, which was deposited through physical vapor deposition. However, this method proved to be less conductive than desired, potentially due to the rough surface topography arising from the 3D printed molds used in the fabrication process.\u003c/p\u003e \u003cp\u003eTo establish a contact that is both reliable and durable, nanoscale sculptured aluminum was considered. In this approach, 100 \u0026micro;m-thick aluminum sheets underwent an etching process employing hydrochloric acid (HCl) from one side. The HCl solution was prepared at a concentration of 7.25 wt.%, and etching was carried out at room temperature without stirring. This procedure yielded a distinctive hook-like structure comprised of cuboids, oriented at 90\u0026deg; angles to each other. This etching technique exhibited no preferential grain boundary dissolution, but it is defined by the crystallographic orientation of the grains. Specifically, the {100} plane is more stable, resulting in flat surfaces at both nanometer and micrometer scales \u003csup\u003e19\u003c/sup\u003e.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec8\" class=\"Section2\"\u003e \u003ch2\u003e5.3 Electret fabrication\u003c/h2\u003e \u003cp\u003eThe electrets utilized in the current sensors are made from 1 mm thick bulk Polytetrafluoroethylene (PTFE or Teflon) with dimensions of 12 mm \u0026times; 12 mm, which were obtained from a larger sheet. A self-built corona discharge setup \u003csup\u003e20\u003c/sup\u003e was utilized to impart surface charges on the PTFE. The setup consisted of a metal sheet serving as the ground electrode, with the PTFE placed atop it and a wire serving as the discharge electrode. A voltage of 5 kV was applied for 1 minute. It is important to allow the electret to rest for at least one day prior to use in the sensor to ensure that any shallow charges that may contribute to sensor noise and negatively impact the limit of detection have dissipated.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec9\" class=\"Section2\"\u003e \u003ch2\u003e5.4 Sensor assembly\u003c/h2\u003e \u003cp\u003eThe sensor housing (cf. Figure\u0026nbsp;\u003cspan refid=\"Fig6\" class=\"InternalRef\"\u003e1\u003c/span\u003e) was fabricated using a \u0026ldquo;Form 2\u0026rdquo; 3D printer from Formlabs. The Clear V4 resin was used and the part was printed at a resolution of 50 micrometers. The cube-shaped design features clamps for securing the electret on the bottom and the cantilever on the top, with the option of using a double-clamped cantilever for various excitation modes. Its size and shape allow for insertion into a coil pair used to generate magnetic fields for the measurements, but it cannot rotate once inserted. Measurements along all three directions in space can be performed. A copper sheet with a cable soldered to it is attached to the cube, serving as the sensing contact for picking up the generated signal by the MPC. A separate copper contact is positioned near the MPC and used as a reference, enabling differential sensor readout, and reducing overall noise.\u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003cp\u003e \u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec10\" class=\"Section2\"\u003e \u003ch2\u003e5.5 Magnetic field measurements\u003c/h2\u003e \u003cp\u003eThe magnetic field measurements were performed with a custom-made setup, which is placed on a vibration-proof table. A coil pair is used to generate AC and DC magnetic fields. The DC-coil has approximately 1500 windings and is used to generate a magnetic bias field to operate the sensor at the optimal working point. The AC-coil has around 750 windings and creates the desired AC magnetic field, which can be detected by the sensor. Both coils have a length of 15 cm. Everything is in a metal box to shield the sensor from electrical noise coming from the environment. In addition, a thin aluminum tube is inserted into the coils for additional electrical shielding. Both parts are connected to the ground. The coils are wrapped in 5 isolated layers of Mu-Metal with a thickness of 300 \u0026micro;m to shield the sensor from magnetic noise.\u003c/p\u003e \u003cp\u003eThe sensor has a mechanical resonance frequency at which it is most sensitive. This is determined by a sinusoidal frequency sweep in steps of 2 Hz, followed by a high-resolution measurement to determine the exact frequency \u003csup\u003e18\u003c/sup\u003e. During these measurements, a constant field strength of 100 \u0026micro;T is used. Next, a DC bias field measurement is conducted. This involves applying a constant AC field with a frequency matching to the resonance frequency of the sensor, with an amplitude of 100 \u0026micro;T. A DC field ranging from \u0026minus;\u0026thinsp;1 mT to 1 mT is then applied in both directions, in order to ensure that the magnetization of the sensor remains unchanged. The optimum working point is identified as the point at which the sensor produces the highest signal. Finally, the smallest detectable field is determined through a series of measurements in which the sensor is operated under ideal bias field conditions and in resonance. During each measurement, the AC magnetic field is gradually reduced. At one point, the generated AC magnetic field reaches the sensor\u0026rsquo;s noise level. At a certain point, the generated AC magnetic field approaches the sensor\u0026rsquo;s noise level. At this juncture, the noise power produced by the sensor surpasses the signal power of the generated magnetic field.\u003c/p\u003e \u003c/div\u003e"},{"header":"Declarations","content":"\u003ch1\u003eAcknowledgement\u003c/h1\u003e\n\u003cp\u003eThis work was supported by the German Research Foundation (Deutsche Forschungsgemeinschaft, DFG) under project 286471992 (Collaborative Research Centre 1261, \u0026ldquo;Magnetoelectric Sensors: From Composite Materials to Biomagnetic Diagnostics\u0026rdquo;).\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Information\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eDECLARATION OF COMPETING INTERESTS\u003c/p\u003e\n\u003cp\u003eThe authors declare that they have no known competing financial interests or personal relationships that could have influenced the work reported in this paper.\u003c/p\u003e\n\u003cp\u003eData Availability:\u003c/p\u003e\n\u003cp\u003eAll relevant data are available from the corresponding author Rainer Adelung, [email protected] upon reasonable request. Any additional information required to replicate the results of this study is also available from the corresponding author upon reasonable request.\u003c/p\u003e\u003cp\u003eAuthor contribution statement\u003c/p\u003e\n\u003cp\u003eLukas Zimoch\u003csup\u003e1\u003c/sup\u003e: Prepared draft, sample preparation, measurements, data evaluation, figure preparation\u003c/p\u003e\n\u003cp\u003eStefan Schr\u0026ouml;der\u003csup\u003e2\u003c/sup\u003e: sample preparation, scientific discussion\u003c/p\u003e\n\u003cp\u003eEric Elzenheimer\u003csup\u003e3, 4\u003c/sup\u003e: Measurements, data evaluation, proofreading\u003c/p\u003e\n\u003cp\u003eS\u0026ouml;ren Kaps\u003csup\u003e1\u003c/sup\u003e: Supervision, scientific discussion, proofreading\u003c/p\u003e\n\u003cp\u003eThomas Strunskus\u003csup\u003e2\u003c/sup\u003e: Scientific discussion, proofreading\u003c/p\u003e\n\u003cp\u003eFranz Faupel\u003csup\u003e2\u003c/sup\u003e: Acquisition, scientific discussion, proofreading\u003c/p\u003e\n\u003cp\u003eMichael H\u0026ouml;ft\u003csup\u003e3\u003c/sup\u003e: Acquisition, scientific discussion, proofreading\u003c/p\u003e\n\u003cp\u003eRainer Adelung\u003csup\u003e*, 1\u003c/sup\u003e: Acquisition, supervision, scientific discussion, proofreading\u003c/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\n\u003cli\u003eMelzer, M., Makarov, D. \u0026amp; Schmidt, O. G. A review on stretchable magnetic field sensorics. \u003cem\u003eJ. Phys. D: Appl. Phys. \u003c/em\u003e\u003cstrong\u003e53, \u003c/strong\u003e83002; 10.1088/1361-6463/ab52cf (2020).\u003c/li\u003e\n\u003cli\u003eFagaly, R. L. Superconducting quantum interference device instruments and applications. \u003cem\u003eReview of Scientific Instruments \u003c/em\u003e\u003cstrong\u003e77\u003c/strong\u003e; 10.1063/1.2354545 (2006).\u003c/li\u003e\n\u003cli\u003eSternickel, K. \u0026amp; Braginski, A. I. Biomagnetism using SQUIDs: status and perspectives. \u003cem\u003eSupercond. Sci. Technol. \u003c/em\u003e\u003cstrong\u003e19, \u003c/strong\u003eS160-S171; 10.1088/0953-2048/19/3/024 (2006).\u003c/li\u003e\n\u003cli\u003eAnnapureddy, V.\u003cem\u003e et al. \u003c/em\u003eA pT/\u0026radic;Hz sensitivity ac magnetic field sensor based on magnetoelectric composites using low-loss piezoelectric single crystals. \u003cem\u003eSensors and Actuators A: Physical \u003c/em\u003e\u003cstrong\u003e260, \u003c/strong\u003e206\u0026ndash;211; 10.1016/j.sna.2017.04.017 (2017).\u003c/li\u003e\n\u003cli\u003eXi, H.\u003cem\u003e et al. \u003c/em\u003eA Room Temperature Ultrasensitive Magnetoelectric Susceptometer for Quantitative Tissue Iron Detection. \u003cem\u003eScientific reports \u003c/em\u003e\u003cstrong\u003e6, \u003c/strong\u003e29740; 10.1038/srep29740 (2016).\u003c/li\u003e\n\u003cli\u003eBoto, E.\u003cem\u003e et al. \u003c/em\u003eA new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers. \u003cem\u003eNeuroImage \u003c/em\u003e\u003cstrong\u003e149, \u003c/strong\u003e404\u0026ndash;414; 10.1016/j.neuroimage.2017.01.034 (2017).\u003c/li\u003e\n\u003cli\u003eZhang, R.\u003cem\u003e et al. \u003c/em\u003eRecording brain activities in unshielded Earth\u0026rsquo;s field with optically pumped atomic magnetometers. \u003cem\u003eApplied Physics\u003c/em\u003e; 10.1126/sciadv.aba8792 (2020).\u003c/li\u003e\n\u003cli\u003eMurzin, D.\u003cem\u003e et al. \u003c/em\u003eUltrasensitive Magnetic Field Sensors for Biomedical Applications. \u003cem\u003eSensors (Basel, Switzerland) \u003c/em\u003e\u003cstrong\u003e20\u003c/strong\u003e; 10.3390/s20061569 (2020).\u003c/li\u003e\n\u003cli\u003eElzenheimer, E.\u003cem\u003e et al. \u003c/em\u003eInvestigation of Converse Magnetoelectric Thin-Film Sensors for Magnetocardiography. \u003cem\u003eIEEE Sensors J. \u003c/em\u003e\u003cstrong\u003e23, \u003c/strong\u003e5660\u0026ndash;5669; 10.1109/JSEN.2023.3237910 (2023).\u003c/li\u003e\n\u003cli\u003ePiorra, A.\u003cem\u003e et al. \u003c/em\u003eMagnetoelectric thin film composites with interdigital electrodes. \u003cem\u003eApplied Physics Letters \u003c/em\u003e\u003cstrong\u003e103\u003c/strong\u003e; 10.1063/1.4812706 (2013).\u003c/li\u003e\n\u003cli\u003eLiu, H., Or, S. W. \u0026amp; Tam, H. Y. Magnetostrictive composite\u0026ndash;fiber Bragg grating (MC\u0026ndash;FBG) magnetic field sensor. \u003cem\u003eSensors and Actuators A: Physical \u003c/em\u003e\u003cstrong\u003e173, \u003c/strong\u003e122\u0026ndash;126; 10.1016/j.sna.2011.11.005 (2012).\u003c/li\u003e\n\u003cli\u003eChen, J., Huang, S.-Y., Lin, C.-Y. \u0026amp; Liu, W.-F. A Low-Frequency Magnetic Field Sensor Based on Fiber Bragg Gratings. \u003cem\u003ePhotonics \u003c/em\u003e\u003cstrong\u003e9, \u003c/strong\u003e102; 10.3390/photonics9020102 (2022).\u003c/li\u003e\n\u003cli\u003eMintken, M.\u003cem\u003e et al. \u003c/em\u003eNanogenerator and piezotronic inspired concepts for energy efficient magnetic field sensors. \u003cem\u003eNano Energy \u003c/em\u003e\u003cstrong\u003e56, \u003c/strong\u003e420\u0026ndash;425; 10.1016/j.nanoen.2018.11.031 (2019).\u003c/li\u003e\n\u003cli\u003eGlavan, G., Belyaeva, I. A., Ruwisch, K., Wollschl\u0026auml;ger, J. \u0026amp; Shamonin, M. Magnetoelectric Response of Laminated Cantilevers Comprising a Magnetoactive Elastomer and a Piezoelectric Polymer, in Pulsed Uniform Magnetic Fields. \u003cem\u003eSensors (Basel, Switzerland) \u003c/em\u003e\u003cstrong\u003e21\u003c/strong\u003e; 10.3390/s21196390 (2021).\u003c/li\u003e\n\u003cli\u003eLiu, C.\u003cem\u003e et al. \u003c/em\u003eMultiparameter sensor based on micro/nano-structured optical fiber and composites. \u003cem\u003eHeliyon \u003c/em\u003e\u003cstrong\u003e8, \u003c/strong\u003ee10941; 10.1016/j.heliyon.2022.e10941 (2022).\u003c/li\u003e\n\u003cli\u003eHu, T., Xuan, S., Ding, L. \u0026amp; Gong, X. Liquid metal circuit based magnetoresistive strain sensor with discriminating magnetic and mechanical sensitivity. \u003cem\u003eSensors and Actuators B: Chemical \u003c/em\u003e\u003cstrong\u003e314, \u003c/strong\u003e128095; 10.1016/j.snb.2020.128095 (2020).\u003c/li\u003e\n\u003cli\u003eNorhaniza, R.\u003cem\u003e et al. \u003c/em\u003eEnhancement of sensitivity of magnetostrictive foam in low magnetic fields for sensor applications. \u003cem\u003ePolymer \u003c/em\u003e\u003cstrong\u003e211, \u003c/strong\u003e123083; 10.1016/j.polymer.2020.123083 (2020).\u003c/li\u003e\n\u003cli\u003eElzenheimer, E.\u003cem\u003e et al. \u003c/em\u003eQuantitative Evaluation for Magnetoelectric Sensor Systems in Biomagnetic Diagnostics. \u003cem\u003eSensors (Basel, Switzerland) \u003c/em\u003e\u003cstrong\u003e22\u003c/strong\u003e; 10.3390/s22031018 (2022).\u003c/li\u003e\n\u003cli\u003eBaytekin-Gerngross, M., Gerngross, M. D., Carstensen, J. \u0026amp; Adelung, R. Making metal surfaces strong, resistant, and multifunctional by nanoscale-sculpturing. \u003cem\u003eNanoscale horizons \u003c/em\u003e\u003cstrong\u003e1, \u003c/strong\u003e467\u0026ndash;472; 10.1039/c6nh00140h (2016).\u003c/li\u003e\n\u003cli\u003eSchr\u0026ouml;der, S., Strunskus, T., Rehders, S., Gleason, K. K. \u0026amp; Faupel, F. Tunable polytetrafluoroethylene electret films with extraordinary charge stability synthesized by initiated chemical vapor deposition for organic electronics applications. \u003cem\u003eScientific reports \u003c/em\u003e\u003cstrong\u003e9, \u003c/strong\u003e2237; 10.1038/s41598-018-38390-w (2019).\u003c/li\u003e\n\u003cli\u003eGerhardt, M.\u003cem\u003e et al. \u003c/em\u003eSelf-powered elementary hybrid magnetoelectric sensor. \u003cem\u003eNano Energy \u003c/em\u003e\u003cstrong\u003e115, \u003c/strong\u003e108720; 10.1016/j.nanoen.2023.108720 (2023).\u003c/li\u003e\n\u003cli\u003eLeVier_WHAT IS SILICONE_1995.\u003c/li\u003e\n\u003cli\u003eBaumann, J., G\u0026ouml;ger, D. \u0026amp; Kiencke, U. A MAGNETO-ELASTIC SENSOR FOR MEASURING PRESSURE OSCILLATIONS IN COMMON RAIL SYSTEMS. \u003cem\u003eIFAC Proceedings Volumes \u003c/em\u003e\u003cstrong\u003e38, \u003c/strong\u003e67\u0026ndash;72; 10.3182/20050703-6-CZ-1902.01899 (2005).\u003c/li\u003e\n\u003cli\u003eZhou, Y.\u003cem\u003e et al. \u003c/em\u003eEnhanced non-bias-field magnetoelectric response with high detectivity in a sensing system based on electret film and magnetostrictive material. \u003cem\u003eMeasurement \u003c/em\u003e\u003cstrong\u003e207, \u003c/strong\u003e112365; 10.1016/j.measurement.2022.112365 (2023).\u003c/li\u003e\n\u003cli\u003eSchoinas, S., El Guamra, A.-M., Moreillon, F. \u0026amp; Passeraub, P. Fabrication and Characterization of a Flexible Fluxgate Sensor with Pad-Printed Solenoid Coils. \u003cem\u003eSensors (Basel, Switzerland) \u003c/em\u003e\u003cstrong\u003e20\u003c/strong\u003e; 10.3390/s20082275 (2020).\u003c/li\u003e\n\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"[email protected]","identity":"scientific-reports","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"scirep","sideBox":"Learn more about [Scientific Reports](http://www.nature.com/srep/)","snPcode":"","submissionUrl":"","title":"Scientific Reports","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Scientific Reports","inReviewEnabled":true,"inReviewRevisionsEnabled":true},"keywords":"Magnetostrictive Polymer Composite (MPC), Nanoscale Sculptured Aluminum, Electret, Magnetic Field Sensor, Sensor Evaluation","lastPublishedDoi":"10.21203/rs.3.rs-4600004/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-4600004/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003eThe pursuit for advanced magnetoelectric field sensors has gained momentum, driven by applications in various fields, ranging from biomedical applications to soft robotics and the automotive sector. In this context, a capacitive read-out based magnetostrictive polymer composite (MPC) sensor element is introduced, offering a new perspective on magnetic field detection. The sensor element's unique feature is the possibility to independently tailor its mechanical and magnetic properties.\u003c/p\u003e \u003cp\u003eWhen compared to other composite-based magnetic field sensors, the limit of detection (LoD) is three orders of magnitude lower (95.6 nT/\u0026radic;Hz at a resonance frequency of 160.5 Hz). In contrast to other electret-based ME sensors, the LoD is reduced by a factor of 20. To the best of the authors' knowledge, this work marks the first comprehensive attempt to characterize a sensor magnetically, aligning with the thorough assessment standards of ME sensors. This study aims to narrow the disparity between established magnetic field sensors, featuring consistent characterization protocols, and the novel MPC sensors, which often undergo limited magnetic characterization as part of their evaluation. The presented sensor, built from readily available materials, offers a versatile and tuneable platform for magnetic field detection, and ongoing research aims to unlock its full potential in diverse applications.\u003c/p\u003e","manuscriptTitle":"Electret Integrated Magnetic Field Sensor Based on Magnetostrictive Polymer Composite with nT Resolution","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2024-07-05 05:45:09","doi":"10.21203/rs.3.rs-4600004/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"decision","content":"Revision requested","date":"2024-10-09T07:10:10+00:00","index":"","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2024-10-08T01:12:52+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"11866880422026396856448727853894458825","date":"2024-09-05T00:47:33+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"24464375549989382243553479018813790011","date":"2024-07-13T20:38:45+00:00","index":"hide","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2024-07-12T07:52:07+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"142629065018654740595783795439009323725","date":"2024-07-09T10:34:01+00:00","index":"hide","fulltext":""},{"type":"reviewersInvited","content":"","date":"2024-06-24T15:44:58+00:00","index":"","fulltext":""},{"type":"editorAssigned","content":"","date":"2024-06-24T15:39:05+00:00","index":"","fulltext":""},{"type":"editorInvited","content":"","date":"2024-06-21T14:41:56+00:00","index":"","fulltext":""},{"type":"checksComplete","content":"","date":"2024-06-19T10:12:57+00:00","index":"","fulltext":""},{"type":"submitted","content":"Scientific Reports","date":"2024-06-18T12:31:57+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"[email protected]","identity":"scientific-reports","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"scirep","sideBox":"Learn more about [Scientific Reports](http://www.nature.com/srep/)","snPcode":"","submissionUrl":"","title":"Scientific Reports","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"stoa","reportingPortfolio":"Scientific Reports","inReviewEnabled":true,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"29a81c09-79cf-4b1a-9ba4-a1011609ba0a","owner":[],"postedDate":"July 5th, 2024","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[],"tags":[],"updatedAt":"2025-01-13T16:05:19+00:00","versionOfRecord":{"articleIdentity":"rs-4600004","link":"https://doi.org/10.1038/s41598-024-85069-6","journal":{"identity":"scientific-reports","isVorOnly":false,"title":"Scientific Reports"},"publishedOn":"2025-01-10 15:58:07","publishedOnDateReadable":"January 10th, 2025"},"versionCreatedAt":"2024-07-05 05:45:09","video":"","vorDoi":"10.1038/s41598-024-85069-6","vorDoiUrl":"https://doi.org/10.1038/s41598-024-85069-6","workflowStages":[]},"version":"v1","identity":"rs-4600004","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-4600004","identity":"rs-4600004","version":["v1"]},"buildId":"qtupq5eGEP_6zYnWcrvyt","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2024) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-06-04T02:00:05.705006+00:00
License: CC-BY-4.0