Abstract
Importance: SARS-CoV-2 genom ic variants impacts the overall sensitivity of COVID -19
diagnosis, leading to false-negative diagnosis and the continued spread of the virus. Objective:
To evaluate how nucleotide variability in target primer binding sites of the SARS-CoV-2
genomes may impact diagnosis using different recommended primer/probe sets, as well as to
suggest the best primer/probes for diagnosis. Design: We downloaded 105,118 public SARS-
CoV-2 genomes from GISAID (Sept, 25th, 2020), r emoved genomes of apparent worst quality
(genome length 5% ambiguous bases) and missing metadata, and performed an
analysis of complementarity for the 13 most used diagnostic primers/probe sets for RT -PCR
detection. We calculated the N rate and % of genome re covery, with all primer/probe -sets
considering viral origin and clade. Results: Our findings indicate that currently, the Paris_nCoV-
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
IP2, -IP4 and WHO|E_Sarbeco primer/probe sets for COVID -19, to perform the best
diagnostically worldwide, recovering >99.5% of the good quality SARS -CoV-2 genomes from
GISAID, with no mismatches . The Chinese_CDC|2019-nCoV-NP primer/probe set, among the
first to be designed during the pandemic, was the most susceptible to currently most abundant
SARS-CoV-2 variants. Mismatches encompassing the binding sites for this set are more frequent
in Clade-GR and are highly prevalent in over 30 countries globally, including Brazil and India ,
two of the hardest hit countries. Conclusions: Detection of SARS -CoV-2 in patients may be
hampered by s ignificant variability in parts of the viral genome that are targeted by some
widely used primer sets. The geographic distribution of different viral clades indicates that
continuous assessment of primer sets via sequencing-based surveillance and viral evolutionary
analysis is critical to accurate diagnostics. This study highlights sequence variance in target
regions that may reduce the efficiency of primer:target hybridization that in turn may lead to
the undetected spread of the virus. As such, due to this variance, the Chinese_CDC|2019-nCoV-
NP-set should be used with caution, or avoided, especially in countries with high prevalence of
the GR clade.
Introduction
The current COVID -19 pandemic that resulted from the global spreading of SARS -CoV-2 has
shown the importance of fast access to reliable viral detection methods. Indeed, v iral
containment measures can only be effective through the fast, broad , and accurate
identification of subjects who carry active infection and may be actively spreading SARS-CoV-
2. In this sense, the identification and isolation of SARS-CoV-2 cases is one of the most effective
means by which to halt the viral spread and to re duce the number of new cases of COVID -19
(1,2).
RT-qPCR using primer (and probe) sets that target selected regions of the viral genome is the
current gold standard and most common diagnostic tool for SARS-CoV-2. Hence, for high
specificity and to avoid fal se-negatives, genomic variants need to be taken into consideration
for the primer/probe designs, such that they can avoid target variations that would restrict or
inhibit primer-template interaction during amplification. Due to continuous evolutionary
selection by targeting sites of the viral genome, as well as viral genome drift, the primers and
probes used for SARS-CoV-2 detection, as well as for other related methods like Loop-mediated
isothermal amplification (LAMP) assays or other similar approaches -- should be constantly
revisited in light of emerging genetic variation and fixation.
Here we evaluated the binding sites of the primers/probes most commonly used for COVID-19
diagnosis, among SARS-CoV-2 genomes downloaded from the GISAID database
(www.gisaid.org - as of Sept., 25th, 2020 - deposited since Dec. 2019 ). This enabled the
investigation of viral genome evolution, diversity and variant -spreading during the COVID -19
pandemics. Our data suggests that the continued emergence of genomic variants in SARS_CoV-
2 may increase false -negative rates and lead us to recommend that: i) the use of
Chinese_CDC|2019-nCoV-NP-set should be immediately discontinued; i i) more than one
primer/probe-set should be used to reduce the frequency of false-negatives; iii) SARS -CoV-2
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
genomic variability should be continuously assessed by sequencing as a means of constant
monitoring variations that may affect diagnosis.
Results
We investigated the capability of 13 of the most used primer/probe sets for COVID-19 diagnosis
(Table S1), to recover SARS-CoV-2 genomes from GISAID considering first no mismatches and
also a maximum of two mismatches. After the exclusion of poor quality genomes (5% of ambiguous ‘N’ bases) or missing metadata, 93,143 genomes remained (88.6%) (Fig. S1).
The places of origin and clades of these viral genomes were also considered and, in some cases,
genomes from distinct locations were clustered ( e.g. England and Scotland , merged as the
United Kingdom). Also, only countries/clusters with at least 10 viral genomes available were
evaluated.
The Chinese_CDC|2019-nCoV-NP set displayed acceptable recovery rates in a few countries
from Asia (Fig. 1a and Table S2). Despite this, this set performs poorly in recovering most SARS-
CoV-2 genomes from GISAID. When no mismatches are allowed , recovery rates below 60%
were obtained for >30 countries on three different continents (South America, Europe and
Asia), including countries with significant burden such as India and Brazil ( Fig. 1a). Assuming
that that two mismatches would still allow sensitive amplification, the picture is still worrisome
for most regions of the world (Fig.1b), a finding that reflects expectant evolutionary changes in
this region of the SARS-CoV-2 genome. We observe that the variants in the binding site of the
Chinese_CDC|2019-nCoV-NP set are more frequent in the clade GR, allowing recovery rates
(no mismatches) from 80.8% in North America to 33.9% in Oceania (Table S2). Clade O appears
to concentrate variants in binding sites of US_CDC|2019 -nCoV_N1 and US_CDC|2019 -
nCoV_N3 sets (Fig. 1a, 1c).
Other primer/probe sets also showed low recovery rates for specific regions, such as HKU-N for
Brazil (total 6 variant positions distributed in primers F, R and the probe); US_CDC|2019 -
nCoV_N1 for Malaysia and Singapore (3 variant positions located in primer F and the probe);
and US_CDC|2019-nCoV_N3 for Bahr ain and Kazakhstan (7 varian ts for primers F, R and the
probe) ( Table S3 ). Caution should be used as the numbers of viral genomes in GISAID are
tremendously biased towards Europe and the US, and the minimum of 10 genomes used here
may not reflect actual viral diversity present in some countries.
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Figure 1a
Figure 1b
Brazil
Turkey
Romania
Ecuador
Nigeria
Portugal
United Kingdom
Hungary
Jordan
India
Chile
Austria
Belgium
Uganda
Italy
Japan
Sweden
Switzerland
Gibraltar
Montenegro
Serbia
Bangladesh
Gambia
Greece
Poland
Australia
Oman
Latvia
Russia
Peru
Argentina
Bulgaria
Estonia
Malaysia
Singapore
Bahrein
Kazakhstan
Ireland
Benin
Mali
Egypt
Finland
Lithuania
China
Panama
Denmark
France
Kenya
Georgia
Suriname
Croatia
Luxembourg
Spain
Israel
Thailand
Colombia
Senegal
Indonesia
Uruguay
Morocco
Ukraine
Germany
Netherlands
Canada
Norway
Vietnam
Congo
USA
Mexico
Iceland
SaudiArabia
NIID_2019−nCOV_N_2
CHINA_CDC|2019−nCoV−NP
US_CDC|2019−nCoV_N1
US_CDC|2019−nCoV_N3
WH−NIC−N
HKU−N
WHO|RdRP_SARSr
CHINA_CDC|2019−nCoV−OP
Hongkong|HKU−ORF1b−nsp14
Paris|nCoV_IP2
WHO|E_Sarbeco
Paris|nCoV_IP4
US_CDC|2019−nCoV_N2
clade
p
Continent Continent
Africa
Asia
Central America
Europe
North America
Oceania
South America
p
90
30
clade
G
GH
GR
L
O
S
0
0.2
0.4
0.6
0.8
1
Luxembourg
Spain
Singapore
Bahrein
China
Finland
Malaysia
Suriname
Georgia
Denmark
France
Croatia
Lithuania
Kenya
Benin
Egypt
Mali
Kazakhstan
Panama
Canada
Congo
Israel
Indonesia
Colombia
Thailand
USA
Senegal
Norway
Mexico
Vietnam
Ireland
Ukraine
Uruguay
Iceland
SaudiArabia
Germany
Netherlands
Australia
Poland
Greece
Peru
Oman
Russia
Gibraltar
Montenegro
Serbia
Brazil
Bangladesh
Gambia
Morocco
Austria
Belgium
Chile
Italy
Jordan
Sweden
Uganda
India
Switzerland
Argentina
Bulgaria
Estonia
Turkey
Japan
Romania
United Kingdom
Hungary
Portugal
Nigeria
Ecuador
Latvia
CHINA_CDC|2019−nCoV−NP
CHINA_CDC|2019−nCoV−OP
Hongkong|HKU−ORF1b−nsp14
NIID_2019−nCOV_N_2
HKU−N
WHO|RdRP_SARSr
WH−NIC−N
US_CDC|2019−nCoV_N2
WHO|E_Sarbeco
US_CDC|2019−nCoV_N1
Paris|nCoV_IP2
Paris|nCoV_IP4
US_CDC|2019−nCoV_N3
clade
p
Continent Continent
Africa
Asia
Central America
Europe
North America
Oceania
South America
p
90
30
clade
G
GH
GR
L
O
S
0.2
0.4
0.6
0.8
1
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Figure 1c
Legend Figure 1: Heatmaps showing recovery rates of genomes from distinct countries of the
world according to the presence of nucleotide variants in the binding sites of primers/probes
and SARS -CoV-2 genomes. The recovery rate results when the requirement of a perfect
complementarity between primers/probes for successful amplification is applied is shown in
Fig. 1a, whereas recovery rates when up to two mismatches are allowed (Fig. 1b). Top colored
lines indicate the continental location of the countries; the next two lines show the proportion
of the predominant clade in a particular region (p) and the respective predominant clade
(clades). Fig. 1c shows the efficacy of viral recovery (no mismatches allowed) for each viral clade
and for each primer/probe set. Numbers inside parentheses indicate the number of genomes
0.00
0.94
0.99
0.99
0.99
0.99
1.00
1.00
0.98
0.99
1.00
0.98
0.99
0.00
0.97
0.99
0.99
0.99
0.99
0.99
1.00
0.99
1.00
0.99
0.99
0.98
0.00
0.00
0.99
0.99
0.98
0.98
1.00
1.00
1.00
0.99
0.99
0.98
0.99
0.00
0.99
0.99
0.98
1.00
1.00
0.99
0.99
1.00
1.00
1.00
0.97
0.99
0.00
0.95
0.59
0.89
0.99
0.99
1.00
0.99
0.98
0.98
0.98
0.98
0.99
0.00
0.95
0.94
0.99
0.99
0.99
1.00
1.00
1.00
1.00
1.00
0.99
1.00
0.00
0.97
0.96
1.00
1.00
0.99
1.00
0.99
1.00
1.00
1.00
0.98
0.96
G (21375)
GH (22620)
GR (32739)
L (3592)
O (3264)
S (5053)
V (4500)
NIID_2019−nCOV_N_2
CHINA_CDC|2019−nCoV−NP
US_CDC|2019−nCoV_N1
US_CDC|2019−nCoV_N3
HKU−N
US_CDC|2019−nCoV_N2
Paris|nCoV_IP2
WHO|E_Sarbeco
WHO|RdRP_SARSr
Hongkong|HKU−ORF1b−nsp14
Paris|nCoV_IP4
CHINA_CDC|2019−nCoV−OP
WH−NIC−N
0
0.2
0.4
0.6
0.8
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
for a given clade. For the NIID_2019-nCOV_N_2 and WHO_RdRP_R sets, see Suppl. Information
for typos and errors in published primer-sequences.
Next, we investigated the temporal prevalence of each clade since the start of the pandemic.
We charted significant fluctuations in clade prevalence and found SARS-CoV-2 clades G, GH and
GR to have increased significantly relative to others, suggestive of positive selection of these
variants (Figure 2) . These results however, can also be explained by reduced diagnostic
accuracy as a consequence of the mismatched evolving target sites. Acc ordingly, genomic
variations should be considered when primers/probes sets are to be selected.
When considering the top-three countries in the world in terms of number of COVID -19 cases
(USA, India and Brazil - Fig. S2) we see that - despite the reduced number of genomes from
Brazil - the proportion of viral clades varies significantly for all these 3 countries . This result
highlights the importance of considering regional and temporal clade structures for selecting
primer/probe sets for diagnosis.
Legend Figure 2 - Percentage of SARS-CoV-2 clades in the world according to month when the
sequences were deposited in GISAID. The number of genomes from each month are indicated
(parenthesis). Genomes with no information about the month in which they were sequenced
(~1%) have not been considered.
As an exercise to evaluate variations in the binding sites from patient -derived samples that
utilized RNA-sequencing to profile the virus, we also analyzed the shotgun sequencing of 926
COVID-19 positive samples from New York -Presbyterian and Weill Cornell Medicine patients,
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
from New York City. Again, most mismatches were seen for the Chinese_CDC|2019 -nCoV-NP
set, but we have also observed variations in the binding sites for the reverse primers of the
US_CDC|2019-nCoV_N2 and N3 sets as well as WH_NIC sets (Fig. S3). The most frequent SARS-
CoV-2 genomic alteration affecting the Chinese_CDC|2019-nCoV-NP corresponds to the 5’-end
of the binding site of the forward primer ( 3) - a continuous stretch of three nucleotide
substitutions (GGG→AAC). Viral genomes with this variation corresponded to ~13% of the
available SARS-CoV-2 genomes as of 22 March 2020 (3) but have now reached ~64% of GISAID
sequences. This variation found in 8 8% of a SARS -CoV-2 genome cohort comprised of 640
sequences from Indian patients and in all of 40 recently confirmed cases in São Paulo, Brazil.
These findings provide multiple lines of evidence of these variations and their significant
frequency in patient-derived samples. Whereas a scenario of high/medium viral load may not
lead to false-negatives after diagnosis with this set (as the most frequent variant would affect
the 5’ end of the F-primer), one possibility is that in cases of low viral loads or less efficient
swabbing, Ct values may be shifted above the detection threshold , leading to false-negatives
and a consequent spreading of this variant. While Vogels et al. 2020 (3), argue that the precise
location of this mismatched sequence may not impact COVID-19 diagnosis, the hypothesis
remains to be tested.
The continued evolution of the virus may result in more variants in these binding sites and other
genome regions and, in this case, the continued use of the Chinese_CDC|2019-nCoV-NP
primer-set may increase false-negatives rates. As can be seen from Table S3 other variants in
the binding sites of F and R primers of the Chinese_CDC|2019-nCoV-NP set have also been
detected in our analysis. Furthermore, it is relevant to document that 2/40 cases sequenced in
Brazil showed two additional substitutions, one detected at the 7th nt from the 5’end (C>A) and
the other at the 4th nt from the 3’end (G>T). These changes, which may have stronger impacts
on primer efficacy – especially if combined with the more upstream mismatches, indicate that
nucleotide substitutions continue to accumulate in this genome region. Importantly, none of
these two extra variations have been described in this GISAID -version, further reinforcing the
need to a continuous effort on cataloguing viral genome sequences.
As the identification of subjects carrying SARS -CoV-2 is in itself an important barrier to the
propagation of the virus, we speculate that the increased global spread of viruses carrying this
variant may be a consequence of using primer/probe sets that fail to properly identify positive
cases. It is worth mentioning the early use of the Chinese_CDC|2019 -nCoV-NP primer set in
earlier manuscripts (4-7). While mass screening is needed to control the spread of the disease,
the lack of proper detection of viruses carrying some variants will not only result in problems
at individual/community level as well as on a glob al scale. Moreover, such missed diagnoses
could contribute to the ongoing spread of the virus , increasing the number of new cases and
deaths from COVID-19, and lead to continued pandemic spread due to misdiagnoses.
The variations seen here may impact COVID-19 diagnosis by RT-PCR, but may also impact other
diagnostic approaches such as LAMP (8) and the Ion AmpliSeq™ SARS -CoV-2 Research Panel .
There we observe that a synonymous variation (c.14143C>T; p.Leu4715Leu; orf1ab) in the
binding site of the ORF1AB primer resulted in decreased coverage of this amplicon by 1-2 orders
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
of magnitude (16/25 samples from a Polish clinical cohort ). An analysis of GISAID genomes
showed this variant to be present in 10% of Polish sequences and in about 17% of sequences
from other European countries as well as other continents (Fig. S4)
Conversely, our study also revealed primers that can currently be used with confidence. Using
current data, we foun d that Paris_nCoV -IP2 and -IP4, and WHO|E_Sarbeco have shown the
best performance in terms of full match to SARS-CoV-2 genomes worldwide, all capturing above
99.5% of the good quality SARS -CoV-2 viruses (Table S4). Importantly, geographic variations
need to be considered and monitored overtime, despite the good performance of these
primers at this time.
Although the current ly observed genome variations would not always impact SARS -CoV-2
detection, since partial amplification can still occur, we propose: i) the use of more than one
primer/probe set to minimize false-negative rates; ii) the use of the Chinese_CDC|2019-nCoV-
NP set to be discontinued; iii) the permanent sequencing surveillance of SARS -CoV-2 genome
around the world , especially from non -primer-biased, environmental samples - allowing viral
genome variant monitoring and the careful selection of the best primers/probes as a means to
reduce false-negatives and disease spreading.
Acknowledgements
– DMC and ED-N acknowledge Conselho Nacional de Pesquisas (CNPq –
Brazil). ED-N is thankful for the support received from Associação Beneficente Alzira Denise
Hertzog Silva (ABADHS, Brazil).
References
1. Peck KR. Early diagnosis and rapid isolation: response to COVID-19 outbreak in Korea. Clin
Microbiol Infect. 2020;26(7):805-807.
2. Lescure FX, Bouadma L, Nguyen D, et al. Clinical and virological data of the first cases of
COVID-19 in Europe: a case series. Lancet Infect Dis. 2020;20(6):697-706.
3. Vogels CBF, Brito AF, Wyllie AL, et al. Analytical sensitivity and efficiency comparisons of
SARS-CoV-2 RT-qPCR primer-probe sets. Nat Microbiol. 2020;5(10):1299-1305.
4. Chen T, Wu D, Chen H et al., Clinical characteristics of 113 deceased patients with
coronavirus disease 2019: retrospective study. Br Med J. 2020;368:m1091.
5. Guan W, Ni Z, Hu Y, et al. Clinical characteristics of coronavirus disease 2019 in China. N
Engl J Med. 2020;382:1708-20.
6. Xu Y, Li X, Zhu B, et al. Characteristics of pediatric SARS-CoV-2 infection and potential
evidence for persistent fecal viral shedding. Nat Med. 2020;26(4):502-505.
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
7. Wang D, Hu B, Hu C, et al. Clinical Characteristics of 138 Hospitalized Patients With 2019
Novel Coronavirus-Infected Pneumonia in Wuhan, China. JAMA. 2020;323(11):1061-1069.
8. Butler D, Mozsary C, Meydan C, et. al. Shotgun transcriptome and isothermal profiling of
SARS-CoV-2 infection reveals unique host responses, viral diversification, and drug
interactions. Pre-print. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7255793/
Supplementary Information
Supplementary Note
The WHO_RdRP_R primer contains an error in a degenerate base at position 12 (instead of S -
C/G – it is certainly a T; see (S1), leading to zero-recovery in our analysis (Fig. 1a). The correction
of this mistake would allow for recovery of 91.19% of GISAID genomes (Fig. S-MCB.1 & S-MCB.2;
see online material for detailed analysis). Extra attention should b e given to this as the wrong
primer sequence is still widely found in the literature.
The NIID_2019-nCOV_N_R2 primer appears to have an error/typo even in the erratum where
it is indicated that “The reverse primer (NIID_2019-nCOV_N_R2) sequence should be replaced
with TGGCAGCTGTGTAGGTCAAC. The corrected nucleotide is bold and underlined.” However,
our analy sis suggest s there to be another typo and the correct primer sequence should be
TGGCACCTGTGTAGGTCAAC (with the previously wrong base marked in bold and underlined).
In order to highlight this discrepancy we performed our searches according to the erratum (S2).
Bioinformatics
Genomes, primers and probes evaluation analyses w ere performed by run ning in -house
pipelines. We first downloaded all SARS-CoV-2 RNA sequences (N=105,118) available at GISAID
as of September 25 th. After removal of Ns from up and downstream of each virus genome
sequence, only genome sequences with at least 29Kb and a maximum of 5% of N (ambiguous
bases) were used for the alignment of primers and probes . The se sequences (N=13
primer/probe sets) were matched against the filtered genomic sequences with the software
bowtie2 (v2.3.5.1) (S3); command line options: --end-to-end --very-sensitive -a ) in paired-end
alignment mode. After, probes sequence from each pair of primers were mapped to each virus
sequence by bowtie2 and then merged with the primer alignments result s. Exact proper pair
alignments allowing up to 2 mismatches outside of the last 5bps of the 3’ end of each primer
were considered for further analyses.
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Table S1 - Primers and probes evaluated
Primer F_primer_seq R_primer_seq P_probe_seq
Chinese_CDC|2019
-nCoV-NP GGGGAACTTCTCCTGCTAGAAT CAGCTTGAGAGCAAAATGTCTG TTGCTGCTGCTTGACAGATT
Chinese_CDC|2019
-nCoV-OP CCCTGTGGGTTTTACACTTAA TCAGCTGATGCACAATCGT
CCGTCTGCGGTATGTGGAAAGGTTATG
G
HKU-NF TAATCAGACAAGGAACTGATTA CATGGAAGTCACACCTTCG GCAAATTGTGCAATTTGCGG
Hongkong|HKU-
ORF1b-nsp14 TGGGGYTTTACRGGTAACCT GAGTGCTTTGTTAAGCGYGTT TAGTTGTGATGCWATCATGACTAG
NIID_2019-
nCOV_N_F2 AAATTTTGGGGACCAGGAAC GTTGACCTACACAGCTGCCA TGTCGCGCATTGGCATGGA
Paris|nCoV_IP2 ATGAGCTTAGTCCTGTTG ACAACACAACAAAGGGAG AGATGTCTTGTGCTGCCGGTA
Paris|nCoV_IP4 GGTAACTGGTATGATTTCG CCTATATTAACCTTGACCAG TCATACAAACCACGCCAGG
US_CDC|2019-
nCoV_N1 GACCCCAAAATCAGCGAAAT CAGATTCAACTGGCAGTAACCAGA ACCCCGCATTACGTTTGGTGGACC
US_CDC|2019-
nCoV_N2 TTACAAACATTGGCCGCAAA TTCTTCGGAATGTCGCGC ACAATTTGCCCCCAGCGCTTCAG
US_CDC|2019-
nCoV_N3 GGGAGCCTTGAATACACCAAAA CAATGCTGCAATCGTGCTACA ACATTGGCACCCGCAATCCTG
WH-NIC-N CGTTTGGTGGACCCTCAGAT AATGGAGAACGCAGTGGGG CAACTGGCAGTAACCA
WHO|E_Sarbeco ACAGGTACGTTAATAGTTAATAGCGT TGTGTGCGTACTGCTGCAATAT ACACTAGCCATCCTTACTGCGCTTCG
WHO|RdRP_SARS* GTGARATGGTCATGTGTGGCGG
TATGCTAATAGTGTSTTTAACATYT
G CAGGTGGAACCTCATCAGGAGATGC
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Table S2 - Chinese_CDC|2019-nCoV-NP primers/probe set performance in the different world
regions with zero mismatches allowed. The percentage of matching sequences were calculated
based on the number of amplicons of non-zero length.
World region Total genomes Genomes matched (%)
Africa 809 80.96
South America 1350 34.44
Oceania 6489 30.68
Asia 6795 69.95
North America 26518 82.57
Europe 51118 54.39
Table S3 - Variations found for SARS-CoV-2 genomes from the GISAID database at each
nucleotide base (from 5’- to 3’-end) of the most varying primer/probe sets according to Figure
1a. Numbers in each cell represent how many genomes carry that specific nucleotide of the
indicated primers or probes.
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Table S4 – Genome recovery rates for different primers and probes, with and without
mismatches.
Genomes recovered with
no mismatches
Genomes recovered with
up to two mismatches
Bad hits1
Primer-set F+R F+R+probe F+R F+R+probe
NIID_2019-nCOV_N 0 0 92950 92918 199
CHINA_CDC|2019-
nCoV-NP
57859 57794 59366 59337 312
US_CDC|2019-
nCoV_N1
92521 90560 92956 92935 219
CHINA_CDC|2019-
nCoV-OP
92090 91769 92332 92181 182
US_CDC|2019-
nCoV_N2
92242 91893 93091 93055 67
US_CDC|2019-
nCoV_N3
92296 91958 93111 93086 68
WH-NIC-N 92140 91958 92863 92848 303
HKU-NF 92258 92009 93064 93023 96
Hongkong|HKU-
ORF1b-nsp14
92486 92268 92826 92608 246
WHO|RdRP_SARSr 92639 92418 93006 92982 113
Paris|nCoV_IP4 92765 92477 93089 93053 103
WHO|E_Sarbeco 92961 92748 93076 92985 114
Paris|nCoV_IP2 92865 92778 93012 92991 152
Note: The total number of genomes investigated is 93,143 . The table has been ordered
according to the total number of recovered genomes, with no mismatches for primers F+R and
the probe. Bad hits 1 indicates genomes with mismatches corresponding to the very 3’ end of
the primers or probes, which shall preclude the proper amplification of the target.
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Suppl. Figures
Figure S1. Analysis pipeline
Fig. S2a - Brazil
0.00
0.25
0.50
0.75
1.00
2020−02 (4)
2020−03 (204)
2020−04 (445)
2020−05 (43)
2020−06 (9)
2020−07 (13)
2020−08 (1)
proportion of total
clade
G
GH
GR
L
O
S
V
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Fig. S2b - India
Fig. S2c - USA
0.00
0.25
0.50
0.75
1.00
2020−01 (2)
2020−03 (133)
2020−04 (396)
2020−05 (851)
2020−06 (780)
2020−07 (110)
2020−08 (181)
2020−09 (2)
proportion of total
clade
G
GH
GR
L
O
S
V
0.00
0.25
0.50
0.75
1.00
2020−01 (14)
2020−02 (98)
2020−03 (6844)
2020−04 (6416)
2020−05 (4188)
2020−06 (5396)
2020−07 (1575)
2020−08 (558)
2020−09 (231)
proportion of total
clade
G
GH
GR
L
O
S
V
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Fig. S3
Legend Fig. S3 -Presence of variations in primer-probe regions found from nasopharyngeal (NP)
swab data from New York -Presbyterian and Weill Cornell Medicine patients. Total RNA was
sequenced and viral reads were isolated and assembled from 926 NP swabs (see Butler et al.,
submitted 2020). Eleven variant alleles across binding sites for 13 primer/probe -sets were
detected in viral genomes isolated from patient samples, including patients who exhibited
variants in the coordinates corresponding to binding sites of the Chine se_CDC|2019-nCoV-NP
set including the 3bp stretch of the forward primer (pos 28881 -28883) and other variations
along the binding site of this same forward primer (28896) as well as its reverse primer (28968
and 28969), along with variants in the binding si tes for reverse primers of US_CDC|2019 -
nCoV_N2 (29218), US_CDC|2019-nCoV_N3 (pos 28747), WH-NIC-N (28373) and the vicinity of
other primers/probes. Color shades correspond to depth of sequencing at each site (low
coverage indicates <= 10 reads covering that site).
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Fig. S4
Figure S4 Variation in primer binding site of AmpliSeq™ SARS -CoV-2 Research Panel -
c.14143C>T; p.Leu 4715Leu; localized in ORF1ab. Top panel shows frequencies for Polish
sequences with the 14408 -variation of multi -aligned coordinates of 225 (110 from MCB, 115
from GISAID) Polish sequences. Bottom panel shows frequencies for other European countries
with t he variation in question localized on position 144858 of multi -aligned coordinates of
52983 European sequences. Variation frequencies found in other continents follow the same
European pattern.
Supplementary References
SR1. Vogels CBF, Brito AF, Wyllie AL, et al. Analytical sensitivity and efficiency comparisons of
SARS-CoV-2 RT-qPCR primer-probe sets. Nat Microbiol. 2020;5(10):1299-1305.
SR2 - https://www.who.int/docs/default-source/coronaviruse/method-niid-20200123-
2.pdf?sfvrsn=fbf75320_7 - Erratum: Nao, N., et al. Detection of second case of 2019-nCoV
infection in Japan.
SR3 - Langmead B, Salzberg SL. Fast gapped-read alignment with Bowtie 2. Nat Methods.
2012; 9(4):357-9.
. CC-BY-NC-ND 4.0 International licenseIt is made available under a
is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.(which was not certified by peer review)preprint
The copyright holder for thisthis version posted December 11, 2020. ; https://doi.org/10.1101/2020.12.10.20236943doi: medRxiv preprint
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.