3D Printed Skull Cap and Benchtop Fabricated Microwire-based Microelectrode Array for Custom Rat Brain Recordings
preprint
OA: closed
CC-BY-NC-ND-4.0
Abstract
Microwire microelectrode arrays (MEAs) have been a popular low-cost tool for chronic electrophysiological recordings. Multi-MEA implantations can reveal electrical dynamics crucial to brain function. However, both the fabrication and implantation procedures for multi-MEAs on a single rodent are time-consuming and highly manual skill-dependent for quality. To enable in-house design, fabrication, and implantation of custom microwire MEAs, we developed (1) a computer-aided designed and 3D printed skull cap for pre-determined implantation locations of each MEA and (2) a benchtop fabrication approach for low-cost custom microwire MEAs. A proof-of-concept design of 32-channel 4-MEA (8-wire each) recording system was prototyped and tested through Sprague Dawley rat recordings. The skull cap design based on CT-scan of single rat conforms well with multiple Sprague Dawley rats of various size, age, and weight with minimal bregma alignment error. The prototyped 32-channel system were able to record spiking activities over 5 months. In comparison with conventional stereotactic surgeries, the skull cap system simplifies the implantation location alignment for each MEA by embedding them into the pre-printed designs, thus dramatically reducing the surgical time and effort and increasing the accuracy and repeatability. Compared to commercially available custom microwire MEAs, this in-house fabrication method enables neuroscience labs to create a custom recording apparatus with lower cost and shorter lead time for design modifications. A new methodology for neuroscience labs to fabricate and insert custom microwire MEAs has been developed and it could be easily generalized to enable low-cost highly-custom multi-region recording/stimulation studies. Highlights 3D printed skull caps as implantation platform for multi-region rat brain recording Computer-aided design for custom cap geometry and predetermined implantation location Benchtop microwire fabrication approach for in-house custom microelectrode arrays Duplicable and generalizable design, fabrication, and implantation methodologies
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00
- unpaywall
- last seen: 2026-05-30T02:00:01.510937+00:00
License: CC-BY-NC-ND-4.0