A survival analysis of bipolar steroid-eluting and unipolar non-steroid-eluting epicardial leads

preprint OA: closed
📄 Open PDF View at publisher
AI-generated summary by gemini-2.5-flash-lite, 2026-06-26

This study performed a survival analysis comparing bipolar steroid-eluting and unipolar non-steroid-eluting epicardial leads.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

Background: Epicardial pacemakers are known as an alternative for endocardial pacemakers in some cases such as heart block, and complex congenital heart diseases. Considering recent advances and improvement of epicardial lead subtypes, it is essential to investigate the long-term function of them. In this study, we aimed to assess the sensing and pacing characteristics, and survival of bipolar steroid-eluting and unipolar non-steroid-eluting epicardial pacemakers. Methods: : We conducted an entirely concentrated search on the documents of all patients who had undergone epicardial lead implantation in the Shaheed Rajaie Cardiovascular, Medical & Research Center during 2015-2018. Implant, and follow up data were extracted. Kaplan Meier analysis and Weibull regression hazards model were applied for the survival analysis. Results: : eighty-nine leads were implanted for 77 patients. Of the total leads, 52.81%, 53.93%, and 47.19% were implanted in children (under-18-year-old), females, and patients with congenital heart diseases, respectively. Bipolar steroid-eluting leads comprised 33.71% of 89 leads. Pacing threshold of unipolar non-steroid-eluting leads that were implanted on the left ventricle and right atrium increased significantly during the follow up to greater records than bipolar steroid-eluting leads. Survival analysis also revealed that bipolar steroid-eluting leads are significantly better in 48-month survival (Weibull HR: 0.13 (95%CI, 0.02-0.99), p-value, 0.049). Age, ventricular location of the lead, and acute pacing characteristics were not associated with survival. Conclusions: : Bipolar steroid-eluting epicardial leads have an acceptable survival compared with unipolar non-steroid-eluting, without a significant difference regarding patients age. Therefore, they could be an excellent alternative for endocardial ones.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-08-30T06:25:36.955031+00:00