Percutaneous coronary angiography and interventions in the porcine model: A feasible and safe proposal

preprint OA: closed CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Background: /Purpose Coronary angiography and percutaneous coronary intervention (PCI) procedural details in swine are similar to those performed to humans, since their heart and coronary anatomy closely resembles. However, only a few detailed descriptions of the procedure are available, containing notable differences. We present a feasible and reproducible protocol for percutaneous coronary interventions in porcine experimental models, utilizing ultrasound-guided femoral approach. Methods/Materials Nine female pigs were studied to explore the feasibility of superficial femoral arterial (SFA) access for coronary angiography and provisional PCI, as well as the most suitable guiding coronary catheters and angiographic projections for the above interventions. Experiments were performed under general anesthesia, using ultrasound-guided puncture of the SFA to gain arterial access. The Amplatzer AR1® catheter, and the Right Coronary Bypass® catheter were used for the selective engagement of the right and the left coronary artery respectively. Results Successful arterial access and subsequent cardiac catheterization were performed in all pigs. Only one animal required a second puncture for femoral artery access. None of the 9 animals presented any significant tachycardia or hypotensive episode. One animal developed an access site-related complication following the first catheterization procedure. During follow-up, 100% success of SFA catheterization was achieved using the same ultrasound-guided technique. Conclusions The ultrasound-guided superficial femoral artery access for coronary angiography and provisional interventions in porcine models is a quick and safe alternative to the carotid artery approach. The RCB and AR1 catheters may be the best choice for the quick and easy selective coronary engagement of the right and left ostia respectively.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-29T02:00:03.542394+00:00
License: CC-BY-4.0