Diagnostic efficacy of single-pass abdominal multidetector-row CT: prospective evaluation of a low dose protocol

Diagnostic accuracy OA: closed
⚙ AI-generated summary by gemini-2.5-flash-lite, 2026-07-17 ⓘ

A low-dose CT protocol with adjusted contrast and noise index safely and effectively diagnosed non-traumatic acute bowel disease in selected patients.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

⚙ AI-generated deep summary by qwen3.7-flash, 2026-08-22 · read from full text ⓘ

This prospective study evaluated the diagnostic efficacy and safety of a low-radiation high-contrast protocol for single-pass abdominal CT in patients with non-traumatic acute bowel disease. The researchers compared younger patients receiving higher contrast doses against older patients receiving standard doses, finding that the adjusted protocol maintained high sensitivity and specificity while significantly reducing radiation exposure without inducing thyrotoxicosis. Although the primary focus is on optimizing imaging techniques for gastrointestinal conditions like inflammatory bowel disease and diverticulitis, the paper mentions abdominal endometriosis as one of several reasons why some patients required additional delayed acquisitions during the scan. Relevance to endometriosis: listed as an incidental finding requiring further imaging, though the paper's main focus is acute bowel disease.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

OBJECTIVE: To evaluate the diagnostic efficacy of single-pass contrast-enhanced multidetector CT (CE-MDCT) performed with a low-radiation high-contrast (LR-HC) dose protocol in selected patients with non-traumatic acute bowel disease. METHODS: 65 (32 males, 33 females; aged 20-67 years) consecutive patients with non-traumatic acute bowel disease underwent single-pass CE-MDCT performed 70-100 s after i.v. bolus injection of a non-ionic iodinated contrast medium (CM) (370 mgI ml-1). In 46 (70%) patients with a clinical and/or ultrasonographic suspicion of inflammatory bowel disease, up to 1.2-1.4 l of a 7% polyethylene-glycol solution was orally administered 45-60 mins prior to the CT examination. Patients were then divided into two groups according to age: Group A (20-44 years; n = 34) and Group B (45-70 years; n = 31). Noise index (NI) and CM dose were selected as follows: Group A (NI = 15; 2.5 ml kg-1) and Group B (NI = 12.5; 2 ml kg-1). All patients of Group A underwent thyroid functional tests at 4-6 weeks. Final diagnoses were obtained by open (n = 12) or laparoscopic surgery (n = 4), endoscopy w/without biopsy (n = 24) and clinical (n = 19) and/or instrumental (ultrasonography) (n = 6) follow-up at 11 ± 4 months (range 6-18 mo.). Statistical analysis was performed by χ2 and Student's t-test for categorical and continuous variables, respectively. RESULTS: Sensitivity and specificity were 91.3 vs 95.4% (p = 0.905) and 90.9 vs 88.8% (p = 0.998) with an overall diagnostic accuracy of 91.1 vs 93.5% (p = 0.756), whereas the radiation (in millisievert) and CM dose (in millilitre) were 7.5 ± 2.8 mSv and 155 ± 30 ml for Group A and 14.1 ± 5.3 mSv and 130 ± 24 ml for Group B (p < 0.001), respectively. No patients of Group A showed laboratory signs of thyrotoxicosis at follow-up. CONCLUSION: The LR-HC has proved to be a safe and a dose-effective protocol in the evaluation of selected young patients with non-traumatic acute bowel disease. Advances in knowledge: (1) As reaching the highest diagnostic benefit to risk ratio (AHARA) appears to be the current principle of MDCT imaging, an increased amount of iodinated CM (0.7-0.9 gI ml-1) can be safely administered to young patients (<40 years) with normal thyroid and renal function to compensate for the lower image quality resulting from low-dose CT protocols performed with the standard filter back-projection algorithm. Such an approach will result in a significant reduction of the radiation dose, which could be otherwise achieved only using iterative reconstruction algorithms combined with either low tube voltage and/or low tube current protocols. (2) An optimal scan delay (Tdelay) for a venous phase caudocranial acquisition can be calculated by the following formula: Tdelay = CI + 25 - TSD, where CI is the duration of the contrast injection, 25 is the average of the sum of abdominal aortic and peak hepatic arrival times and TSD is the scan duration. With such an approach, the radiation exposure resulting from bolus tracking, albeit performed with low-dose scans, can be spared in patients with normal transit times.
Full text 42,286 characters · extracted from oa-html · 11 sections · click to expand

Abstract

Objective: To evaluate the diagnostic efficacy of single-pass contrast-enhanced multidetector CT (CE-MDCT) performed with a low-radiation high-contrast (LR-HC) dose protocol in selected patients with non-traumatic acute bowel disease.

Methods

65 (32 males, 33 females; aged 20–67 years) consecutive patients with non-traumatic acute bowel disease underwent single-pass CE-MDCT performed 70–100 s after i.v. bolus injection of a non-ionic iodinated contrast medium (CM) (370 mgI ml−1). In 46 (70%) patients with a clinical and/or ultrasonographic suspicion of inflammatory bowel disease, up to 1.2–1.4 l of a 7% polyethylene-glycol solution was orally administered 45–60 mins prior to the CT examination. Patients were then divided into two groups according to age: Group A (20–44 years; n = 34) and Group B (45–70 years; n = 31). Noise index (NI) and CM dose were selected as follows: Group A (NI = 15; 2.5 ml kg−1) and Group B (NI = 12.5; 2 ml kg−1). All patients of Group A underwent thyroid functional tests at 4–6 weeks. Final diagnoses were obtained by open (n = 12) or laparoscopic surgery (n = 4), endoscopy w/without biopsy (n = 24) and clinical (n = 19) and/or instrumental (ultrasonography) (n = 6) follow-up at 11 ± 4 months (range 6–18 mo.). Statistical analysis was performed by χ2 and Student's t-test for categorical and continuous variables, respectively.

Results

Sensitivity and specificity were 91.3 vs 95.4% (p = 0.905) and 90.9 vs 88.8% (p = 0.998) with an overall diagnostic accuracy of 91.1 vs 93.5% (p = 0.756), whereas the radiation (in millisievert) and CM dose (in millilitre) were 7.5 ± 2.8 mSv and 155 ± 30 ml for Group A and 14.1 ± 5.3 mSv and 130 ± 24 ml for Group B (p < 0.001), respectively. No patients of Group A showed laboratory signs of thyrotoxicosis at follow-up.

Conclusion

The LR-HC has proved to be a safe and a dose-effective protocol in the evaluation of selected young patients with non-traumatic acute bowel disease. Advances in knowledge: (1) As reaching the highest diagnostic benefit to risk ratio (AHARA) appears to be the current principle of MDCT imaging, an increased amount of iodinated CM (0.7–0.9 gI ml−1) can be safely administered to young patients (<40 years) with normal thyroid and renal function to compensate for the lower image quality resulting from low-dose CT protocols performed with the standard filter back-projection algorithm. Such an approach will result in a significant reduction of the radiation dose, which could be otherwise achieved only using iterative reconstruction algorithms combined with either low tube voltage and/or low tube current protocols. (2) An optimal scan delay (Tdelay) for a venous phase caudocranial acquisition can be calculated by the following formula: Tdelay = CI + 25 − TSD, where CI is the duration of the contrast injection, 25 is the average of the sum of abdominal aortic and peak hepatic arrival times and TSD is the scan duration. With such an approach, the radiation exposure resulting from bolus tracking, albeit performed with low-dose scans, can be spared in patients with normal transit times.

Introduction

Minimizing the radiation dose delivered to patients while preserving the diagnostic accuracy of the CT examination should be a radiologist duty in the current era of multidetector CT (MDCT) technology.1 Indeed, radiologists should always attempt to obtain a diagnostic benefit to risk ratio as high as reasonably achievable (AHARA)1 and such a radiation consciousness should primarily involve patients under 30 years, as the lifetime risk of radiation-induced cancer is greater the younger the patient.2 While several dose reduction strategies can be successfully applied in contrast-enhanced abdominal MDCT, such as the use of iterative reconstruction algorithms combined with either low tube voltage3,4 and/or low tube current protocols,5 these technologies are still not widely available in clinical practice. Moreover, dose reduction in MDCT should primarily result from the optimization of acquisition protocols, as unindicated phases in contrast-enhanced MDCT (CE-MDCT) are a major source of unjustified radiation exposure.6 Radiologists should therefore become familiar with single-pass acquisitions, as they can effectively address the vast majority of clinical questions in contrast-enhanced abdominal CT7 and even in the clinical context of a non-traumatic acute abdomen, there seems to be no diagnostic gain of multiphasic acquisitions compared with venous phase alone.8 However, as improvement in the quality of CT images obtained using low-dose protocols can also be achieved by increasing the amount of iodinated contrast media (CM) administered,9 the possibility of balancing the effects of radiation dose and CM dose on the image quality of contrast-enhanced abdominal CT has been investigated in both an experimental10 as well as a clinical setting.11 In this latter study, we have recently shown that a constant image quality, as assessed by both qualitative and quantitative analysis, could be maintained in contrast-enhanced single-pass multidetector abdominal CT, balancing the amount of radiation and CM dose according to the age of the patients.11 In the present study, we prospectively investigated in the same patient population the diagnostic efficacy of CE-MDCT performed with a low-radiation high-contrast (LR-HC) dose protocol comparing its accuracy with that of a standard dose (SD) protocol in the evaluation of selected patients with non-traumatic acute bowel disease, a clinical condition including several acute gastrointestinal disorders such as inflammatory bowel disease (IBD), acute diverticulitis, small bowel obstruction (SBO) or large bowel obstruction (LBO), infective or autoimmune enteritis, ischaemic or infective colitis etc.12

Methods

AND MATERIALS This prospective study was approved by the local ethical committee board on 26 February 2014, and written informed consent was obtained from all patients. Population From 4 April to 31 October 2014, 80 (41 males, 39 females; aged 20–67 years) consecutive patients referred from the Department of Gastroenterology of our institution to undergo CE-MDCT for non-traumatic acute bowel disease were enrolled in this prospective study. Eligibility criteria included the absence of cardiovascular, renal or thyroid comorbidities. As 12 (15%) patients underwent additional delayed acquisitions for diagnostic needs such as the characterization of incidentally found focal hepatic lesions (n = 4), the evaluation of penetrating Crohn's disease (n = 3), the presence of pelvic abscesses (n = 4) or abdominal wall endometriosis (n = 1) and 3 more patients were lost to follow-up, the final population included 65 patients who were divided into 2 groups according to age: Group A (20–44 years; n = 34, 34 ± 8 years) and Group B (45–70 years; n = 31, 56 ± 7 years). CT technique All patients underwent single-pass CE-MDCT (Aquilion 64™; Toshiba, Tokyo, Japan) with a caudocranial acquisition performed with the following scanning parameters: detector configuration = 1 × 32 mm; table feed 36 mm s−1; rotation time 0.75 s; helical pitch = 27; section thickness = 5 mm; 120 kVp; automated tube current modulation (ATCM). All images were reconstructed with a standard (kernel = 3) filter back-projection algorithm. 46 patients (24 males, 22 females) with a clinical and/or ultrasonographic suspicion of IBD were given 1200–1400 ml of a 7% polyethylene-glycol solution administered orally 45–60′ prior to the CT examination, followed by ingestion of 500 ml of tap water 10–15 mins prior to the CT acquisition.13 For each group, a different noise index (NI) (NI = 12.5 vs 15) was selected in the ATCM system and a different amount (2.0 vs 2.5 ml kg−1) of non-ionic iodinated CM (Iopamiro 370 mgI ml−1; Bracco Imaging, Milan, Italy) was administered as follows: Group A (NI = 15; 2.5 ml kg−1) and Group B (NI = 12.5; 2 ml kg−1). Single-pass contrast-enhanced abdominal CT was then performed according to a LR-HC (NI = 15) (2.5 ml kg−1) dose protocol in Group A and a SD protocol (NI = 12.5; 2 ml kg−1) in Group B. In all patients, the i.v. contrast injection was followed by 100 ml of saline solution administered at the same rate with an automated dual-head injector (Stellant Medrad Inc., Indianola, IA). In each patient, the scan delay was calculated according to the following formula:11 where CI is the duration of contrast injection, TSD is the scan duration and 25 is the average of the sum of the abdominal aortic (15–18 s) and the hepatic arrival times (30–40 s).14 All patients of Group A underwent evaluation of thyroid function (Thyroid Stimulating Hormone or Thyrotropin (TSH), Free triiodothyronine (FT3), Free thyroxine (FT4)) tests at 4–6 weeks to exclude an iodine-induced thyrotoxicosis.15 In all patients, the radiation dose delivered was reported as a dose–length product (in milligray centimetre) and the effective dose (ED) (in millisievert) was calculated by applying a conversion factor of 0.015.16

Reference

standard All CT scans were interpreted by two experienced abdominal radiologists and prospective CT reports were compared with final diagnoses based on open (n = 12) or laparoscopic surgery (n = 4), colonoscopy with (n = 7) or without biopsy (n = 15), gastroscopy (n = 1), ultrasonography-guided biopsy (n = 1) and clinical (n = 19) or instrumental (ultrasonography) follow-up (n = 6) performed at 11 ± 4 months (range 6–18 mo.). Statistical analysis Statistical analysis was performed by using SPSS® v. 20.0 (IBM Corp., New York, NY; formerly SPSS Inc., Chicago, IL). Differences in continuous variables were analyzed by the unpaired Student's t-test, whereas χ2 test was used for categorical variables, both with a level of significance of 0.05.

Results

Patient characteristics Patient features [age, gender, body weight, height and body mass index (BMI)] are summarized in Table 1 along with the serum creatinine (in milligram per millilitre) and Glomerular Filtration Rate (GFR) (millilitre per minute) levels. Gender distribution was similar between Groups A and B, whereas non-significant differences were observed between patient weight, height and BMI of Groups A and B (Table 1). Serum creatinine levels and GFRs of patients of Groups A and B were also not significantly different (Table 1). Table 1. | Patients characteristics | Group A (n = 34) | Group B (n = 31) | p-value | |---|---|---|---| | Age (years) | 20–44 (34 ± 8) | 45–70 (56 ± 7) | – | | Gender | M (n = 17) F (n = 17) | M (n = 15) F (n = 16) | – | | Weight (kg) | 62 ± 12 | 64 ± 13 | 0.428 | | Height (cm) | 167 ± 8 | 165 ± 7 | 0.259 | | BMI (kg m−2) | 21 ± 3 | 23 ± 4 | 0.155 | | GFR (ml min−1) | 106 ± 22 | 97 ± 33 | 0.259 | | Creatinine (mg ml−1) | 0.81 ± 0.17 | 0.75 ± 0.18 | 0.246 | BMI, body mass index. Non-ionic iodinated contrast media No adverse reaction to the non-ionic iodinated CM used was observed in both groups. The amounts of CM injected (in millilitre) were significantly different between the two groups with 155 ± 30 and 128 ± 24 ml for Groups A and B (p < 0.001) corresponding to an iodine dose of 56 ± 11 and 47 ± 8 g, respectively (Table 2). None of the patients of Group A developed signs of thyroid dysfunction at follow-up. Table 2. | Parameter | Group A | Group B | p-value | |---|---|---|---| | DLP (mGy cm) | 500 ± 192 | 940 ± 353 | <0.001 | | ED (mSv) | 7.5 ± 2.8 | 14.1 ± 5.3 | <0.001 | | CM (ml) | 155 ± 30 | 128 ± 24 | <0.001 | | Iodine load (g) | 56 ± 11 | 47 ± 8 | <0.001 | | Scan delay (s) | 76 ± 7 | 78 ± 8 | 0.457 | Effective absorbed dose Dose–length products (in milligray centimetre) and effective absorbed doses (in millisievert) were significantly different between the two groups with respective values of 500 ± 192 mGy cm and 7.5 ± 2.8 mSv for Group A and 940 ± 353 mGy cm and 14.1 ± 5.3 mSv for Group B (p < 0.001) (Table 2). Scan delays Scan delays ranged between 70 and 100 s depending on the duration of contrast injection (CI), which was equal to the body weight as the rate of the injection was kept identical to the amount of iodinated CM administered per kilogram of body weight, and the scan duration which ranged between 12 and 15 s. In detail, scan delays ranged between 70 and 90 s in Group A and between 70 and 100 s in Group B with mean values of 76 ± 7 vs 78 ± 8 s (p = 0.457) for Groups A and B, respectively (Table 2). Diagnostic accuracy Diagnostic accuracies were similar for the LR-HC and the SD protocol with respective values of 91.1% (95% confidence interval = 78.3–98.7) in Group A and 93.5% (95% confidence interval = 81.4–99.2) in Group B (p = 0.756) (Table 3). Sensitivity was higher but not significantly different in Group B (95.4 vs 91.3%; p = 0.905), whereas specificity was higher but not significantly different in Group A (90.9 vs 88.8% p = 0.998) (Table 3). Overall, single-pass CE-MDCT findings were true positive in 42 patients (21 patients in Group A; 21 patients in Group B) and true negative in 18 patients (10 patients in Group A; 8 patients in Group B) with 2 false-negative and 1 false-positive findings in Group A (Table 4) and 1 false-positive and 1 false-negative finding in Group B (Table 5). Table 3. | Diagnostic performance | Group A (CI95%) | Group B (CI95%) | p-value | |---|---|---|---| | Sensitivity | 91.3% (73–98.9) | 95.4% (76.1–99.8) | 0.905 | | Specificity | 90.9% (55.5–99.7) | 88.8% (51.4–98.5) | 0.998 | | Accuracy | 91.1% (78.3–98.7) | 93.5% (81.4–99.2) | 0.756 | | PPV | 95.4% (78–99.8) | 95.4% (78–98.8) | 1 | | NPV | 83.3% (48.2–97.7) | 88.8% (51.7–99.7) | 0.850 | Table 4. | Patient | Age (years) | Sex | CT diagnosis | Reference standard | Test | |---|---|---|---|---|---| | 1 | 31 | F | No evidence of bowel pathology | Clinical follow-up | TN | | 2 | 35 | M | Perforated diverticulitis | Clinical and CT follow-up | TP | | 3 | 31 | F | Budd–Chiari syndrome | Clinical and ultrasonographic follow-up | TP | | 4 | 37 | M | Perforated diverticulitis | Surgery | TP | | 5 | 20 | M | Stricturing Crohn's disease | Retrograde ileoscopy | TP | | 6 | 26 | M | Perforated diverticulitis | Surgery | TP | | 7 | 20 | F | Adhesive SBO | Clinical follow-up | TP | | 8 | 39 | M | Anastomotic fibrotic stricture | Colonoscopy and biopsy (Crohn's recurrence) | FN | | 9 | 44 | F | No evidence of bowel pathology | Clinical follow-up | TN | | 10 | 41 | M | Diverticulosis | Colonoscopy | TN | | 11 | 32 | F | No evidence of bowel pathology | Clinical follow-up | TN | | 12 | 43 | F | Stricturing Crohn's disease | Clinical and ultrasonographic follow-up | TP | | 13 | 29 | M | Penetrating Crohn's disease | Surgery | TP | | 14 | 41 | F | Diverticulosis | Colonoscopy | TN | | 15 | 42 | M | Left ulcerative colitis | Colonoscopy and biopsy | TP | | 16 | 42 | M | Penetrating Crohn's disease | Surgery | TP | | 17 | 44 | F | Adhesive SBO | Clinical follow-up | TP | | 18 | 37 | F | SBO | Clinical and ultrasonographic follow-up (functional disorder) | FP | | 19 | 21 | F | No evidence of bowel pathology | Colonoscopy | TN | | 20 | 39 | M | Stricturing Crohn's disease | Retrograde ileoscopy | TP | | 21 | 44 | M | Penetrating Crohn's disease | Surgery | TP | | 22 | 43 | M | Penetrating Crohn's disease | Surgery | TP | | 23 | 44 | F | Adynamic ileus | Clinical follow-up | TN | | 24 | 44 | F | No evidence of bowel pathology | Retrograde ileoscopy (terminal ileitis) | FN | | 25 | 28 | F | No evidence of bowel pathology | Clinical follow-up | TN | | 26 | 32 | M | Crohn's anastomotic recurrence | Surgery | TP | | 27 | 27 | F | Left ulcerative colitis | Colonoscopy and biopsy | TP | | 28 | 25 | F | No evidence of bowel pathology | Clinical follow-up | TN | | 29 | 34 | M | Stricturing Crohn's disease | Retrograde ileoscopy | TP | | 30 | 25 | M | Left ulcerative colitis | Colonoscopy and biopsy | TP | | 31 | 24 | M | No evidence of bowel pathology | Clinical Follow-up | TN | | 32 | 26 | M | Penetrating Crohn's disease | Surgery | TP | | 33 | 20 | F | Crohn's colitis | Surgery | TP | | 34 | 40 | F | Penetrating Crohn's disease | Surgery | TP | F, female; M, male; SBO, small bowel obstrucion. FN, false negative; FP, false positive; TN, True negative; TP, True positive. Table 5. | Patientt | Age (years) | Sex | CT diagnosis | Reference standard | Test | |---|---|---|---|---|---| | 1 | 58 | M | Ulcerative colitis | Colonoscopy and biopsy | TP | | 2 | 49 | M | Small bowel Crohn's recurrence | Retrograde ileoscopy | TP | | 3 | 59 | M | Sclerosing mesenteritis | Ultrasonography-guided biopsy | TP | | 4 | 60 | M | LBO (sigmoid cancer) | Surgery | TP | | 5 | 57 | M | Diverticulosis | Clinical follow-up | TN | | 6 | 48 | M | No evidence of bowel pathology | Clinical follow-up | TN | | 7 | 55 | F | No evidence of bowel pathology | Colonoscopy | TN | | 8 | 65 | F | No evidence of bowel pathology | Clinical follow-up | TN | | 9 | 60 | F | Stricturing Crohn's disease | Colonoscopy | TP | | 10 | 66 | M | No evidence of bowel pathology | Retrograde ileoscopy (terminal ileitis) | FN | | 11 | 56 | F | LBO (inflammatory stenosis) | Surgery | TP | | 12 | 66 | F | Ischaemic colitis | Colonoscopy | TP | | 13 | 46 | F | Stricturing Crohn's disease | Clinical and ultrasonographic follow-up | TP | | 14 | 52 | M | Diverticulosis | Clinical follow-up | TN | | 15 | 67 | F | Diverticulosis | Clinical follow-up | TN | | 16 | 60 | M | Sclerosing mesenteritis | Surgery | TP | | 17 | 54 | F | Left ulcerative colitis | Colonoscopy and biopsy | TP | | 18 | 67 | M | Ulcerative pancolitis | Colonoscopy and biopsy | TP | | 19 | 45 | M | No evidence of bowel pathology | Clinical follow-up | TN | | 20 | 64 | F | Ulcerative colitis | Colonoscopy and biopsy | TP | | 21 | 50 | M | Penetrating Crohn's disease | Surgery | TP | | 22 | 68 | F | No evidence of bowel pathology | Clinical follow-up | TN | | 23 | 46 | F | Stricturing Crohn's disease | Surgery | TP | | 24 | 57 | F | Crohn's colitis | Colonoscopy (functional disorder) | FP | | 25 | 54 | F | Stricturing Crohn's disease | Clinical and ultrasonographic follow-up | TP | | 26 | 60 | F | Penetrating Crohn's disease | Surgery | TP | | 27 | 49 | F | Peptic stenosis | Gastroscopy | TP | | 28 | 60 | M | Ischaemic colitis | Colonoscopy | TP | | 29 | 46 | M | Stricturing Crohn's disease | Retrograde ileoscopy | TP | | 30 | 53 | M | Stricturing Crohn's disease | Clinical and ultrasonographic follow-up | TP | | 31 | 54 | F | Celiac disease | Clinical follow-up | TP | F, female; LBO, large bowel obstruction; M, male. FN, false negative; FP, false positive; TN, True negative; TP, True positive. In detail, peroral CT enterography performed with an LR-HC protocol (Group A) correctly identified the site, extension and pattern (stricturing or penetrating) of disease in 13 patients with Crohn's disease as assessed by surgery (n = 8) (Figure 1a), colonoscopy with (n = 2) or without (n = 1) biopsy and instrumental (ultrasonography) follow-up (n = 2). True-positive findings were also observed in three patients with ulcerative colitis, as confirmed by colonoscopy with biopsy, whereas true-negative findings were obtained in seven patients, as assessed by endoscopy (n = 3), clinical (n = 2) or instrumental follow-up (n = 2). There were also two false-negative and one false-positive findings (Table 4). In the remaining eight patients of Group A, single-pass CE-MDCT performed with an LR-HC protocol showed true-positive findings in three patients with a perforated acute diverticulitis—two patients operated on and one patient treated conservatively (Figure 2a)—in one patient with Budd–Chiari syndrome and in two patients with adhesive SBO who were both treated conservatively with a nasogastric intubation (Figure 3a), whereas true-negative findings were observed in two patients referred for acute sigmoid diverticulitis, as both confirmed by colonoscopy (Table 4). In Group B, peroral CT enterography (n = 20) correctly identified the site, extension and pattern (stricturing or penetrating) of disease in nine patients with Crohn's disease, as assessed by surgery (n = 3), colonoscopy with (n = 1) or without (n = 2) biopsy (Figure 1b) and clinical and instrumental follow-up (n = 3). True-positive findings were also obtained in four patients with ulcerative colitis, as confirmed by colonoscopy with biopsy, whereas true-negative findings were observed in five patients, as assessed by colonoscopy (n = 1) or clinical and instrumental (ultrasonography) follow-up (n = 4). One false-positive and one false-negative finding was also observed (Table 5). In the remaining 11 patients, true-negative findings were observed in 3 patients referred for acute sigmoid diverticulitis, as confirmed by clinical follow-up, whereas true-positive findings were obtained in 2 patients with non-occlusive ischaemic colitis (Figure 2b), as assessed by colonoscopy in both, in 2 patients with LBO—1 due to a sigmoid cancer and 1 due to a sigmoid inflammatory stenosis (Figure 3b)—who both underwent surgery, and in other 5 patients with miscellaneous disorders such as sclerosing mesenteritis, gastric outlet syndrome and celiac disease (Table 5).

Discussion

As the radiation exposure resulting from unindicated phases in MDCT has become a major issue in the radiological community,6 single-pass protocols have been recommended to address the vast majority of clinical questions in contrast-enhanced abdominal CT.7 Indeed, even in the clinical context of a non-traumatic acute abdomen, there seems to be no diagnostic gain of multiphasic acquisition compared with venous phase alone.8 In the present study, we prospectively investigated the diagnostic efficacy of single-pass CE-MDCT performed according to an LR-HC dose protocol in the evaluation of selected patients with non-traumatic acute bowel disease comparing its accuracy with that of a standard protocol. In the same patient population, we have recently shown that a constant image quality could be maintained balancing the amount of radiation and CM dose according to the age of the patients.11 Indeed, where peak hepatic enhancement was concerned, the LR-HC dose protocol proved to be most dose effective, as the relative figure of merit was significantly higher, despite surprisingly similar signal-to-noise ratios.11 As figure of merit represents the ratio of contrast-to-noise ratio2 to the ED, it is considered a useful mean to compare the effect on image quality of different CT acquisition protocols and to evaluate their dose efficacy.3 In accordance with our previous findings, the present study underscores that the LR-HC is also a dose-effective protocol in the evaluation of selected young patients with non-traumatic acute bowel disease showing a similar diagnostic accuracy as the standard protocol (Table 3) but with a significantly lower ED (Table 2). While several other dose reduction strategies can be successfully applied in CE-MDCT such as the use of iterative reconstruction algorithms to reduce the image noise associated with either low tube voltage or low tube current protocols,3–5 these technologies are still not widely available in clinical practice, whereas our LR-HC protocol simply relies on commercially available ATCM systems to select a higher NI value to reduce the radiation dose,17 compensating the resulting increase in image noise with a larger amount of non-ionic iodinated CM, as first suggested by Watanabe et al.9 To the best of our knowledge, there has been no other study prospectively addressing this issue in clinical practice aside from our previous investigation performed in the same patient population.11 While the possibility of balancing the effect of radiation and CM on image quality was also investigated by Falt et al,10 this was performed retrospectively and the ideal combination of tube load and iodinated contrast to obtain a constant image quality was only extrapolated. While the amounts of non-ionic iodinated CM administered to patients of Group A (0.92 gI kg−1) were largely above the recommended values18 with a mean value of 58 ± 11 g (Table 2), the total iodine load should not be an issue in patients with a normal thyroid15 or renal function.19 Indeed, none of these patients showed signs of a contrast-induced thyrotoxicosis at follow-up. However, recent data seem to indicate that the absorbed dose in contrast-enhanced CT is indeed higher than that in unenhanced acquisition with an average dose increment of 19% for the liver.20 As this is likely the result of the major contribution of photoelectric effect in the attenuation of the X-ray beam by iodine (k-edge = 33.2 keV),21 further studies are needed to assess the benefit to risk ratio of contrast-enhanced examinations in different clinical contexts. In the present one, the LR-HC has resulted in halving of the ED administered to patients of Group A (7.5 ± 2.5 mSv) compared with that delivered to patients of Group B (14.1 ± 5.3 mSv) (Table 2). As there were no significant differences in patient weights, heights and BMI between Groups A and B (Table 1), such a significant dose reduction can be solely attributed to the higher NI value (15 vs 12.5) selected in our ATCM system (Sure Exposure 3D Toshiba, Japan), which was effectively compensated by a significantly higher amount of non-ionic iodinated CM injected (155 ± 30 vs 128 ± 24 cc) (Table 2). As far as the formula we used to calculate the optimal scan delay in each patient is concerned, it was largely derived from the data of Bae,14 with the only difference that the total scan duration was subtracted by the sum of the CI time and the averaged sum of the aortic and peak hepatic transit times. This adjustment was made because in our protocol, hepatic parenchyma was scanned at the end of the caudocranial acquisition.11 As far as the diagnostic performance of our single-pass protocol is concerned, it compares favourably with the most recent literature,8,22,23 with an overall diagnostic accuracy of 91.2% for Group A and 90.3% for Group B (Table 3). There are indeed major discrepancies in the prevalence of different aetiologies of non-traumatic acute bowel disease in our population compared with that of the literature.8,22,23 Several acute gastrointestinal disorders which are fairly common in clinical practice such as appendicitis are not even represented in our population, and the exclusion of patients with cardiac comorbidities may also have underestimated the prevalence of ischaemic bowel disease in Group B. Therefore, further studies are warranted to validate our LR-HC protocol in a larger and unselected series of patients with non-traumatic acute bowel disease. Such discrepancies, however, can be largely accounted for by our institution being a tertiary-care centre without an emergency department but a referral centre for IBD.24 Indeed, up to 70% of the patients (46 out of 65 patients) underwent CE-MDCT performed according to a peroral CT enterography protocol, which is always indicated whenever there is a clinical and/or ultrasonographic suspicion of IBD in the acute setting.25 In particular, peroral CT enterography showed a diagnostic accuracy of 88.4% in Group A and 90% in Group B, both of which are in complete accordance with the literature,26–28 indicating the reliability and reproducibility of CT enterography findings of IBD (Figure 1). As far as the overall radiation dose delivered to patients of Group A is concerned (7.5 ± 2.5 mSv), it also compares favourably with the data reported by both Kambadakone et al26 and Ippolito et al28 using low-dose CT enterography protocols, which resulted in EDs of 8.6 ± 2.5 and 9.07 ± 2.71 mSv, respectively, whereas they were higher than the values reported by Kaza et al27 using low-kilovoltage CT enterography protocols which delivered EDs as low as 4.6 ± 1.05 mSv. However, all these studies used iterative methods such as reconstruction algorithms and compared them with either filter back-projection26,27 or the use of standard kilovoltage settings,28 which respectively resulted in EDs of 14 ± 6, 14.6 ± 6.6 and 15.8 ± 3.7 mSv, all comparable with the figures observed in the present study in Group B (Table 2). While the radiation exposure would not be a concern using MR enterograhy, which has indeed shown a similar diagnostic accuracy as CT enterography in evaluating Crohn's disease similar to CT enterography,29 MR is less suited for the acute setting.25 This is mainly due to the complexity and overall duration of the MR examination, which may also result in a suboptimal image quality compared with CT enterography.29 In the eight patients referred for acute diverticulitis, single-pass CE-MDCT performed with either an LR-HC (n = 5) (Figure 2a) or a standard protocol (n = 3) did not show false-negative or false-positive findings with an overall diagnostic accuracy of 100%. While this figure is likely the result of the small sample size, a diagnostic accuracy as high as 98% has been reported in a much larger series by Werner et al.30 Similarly, no false-negative or false-positive results were observed in the four patients referred for either SBO or LBO, who underwent single-pass CE-MDCT according to either the LR-HC protocol (n = 2) (Figure 3a) or the standard protocol (n = 2) (Figure 3b). However, the diagnostic role of CE-MDCT in the clinical setting of either SBO or LBO is well acknowledged and undisputed.31 True-positive findings were finally observed in two patients with non-occlusive ischaemic colitis (Figure 2b), whose CT findings are often pathognomonic,32 and in other miscellaneous disorders such as acute Budd–Chiari syndrome, which usually manifests with hepatic vein thrombosis,33 gastric outlet syndrome and sclerosing mesenteritis. This latter patient has been described in detail elsewhere.34 Our study has several limitations. First, there was a selection bias in patient enrolment, as patients with thyroid, cardiovascular or renal comorbidities were excluded. However, as we did not use a bolus tracking technique, patients with cardiac diseases had to be excluded because of unpredictable transit times,14 whereas the presence of either thyroid or renal comorbidities represented a contraindication for being included in the LR-HC protocol, considering that the amount of iodine administered to this group was above the recommended values.18 Second, the prevalence of different aetiologies in the present series is quite different from that reported in the literature.8,22,23 However, we wanted to test our protocol in the evaluation of non-traumatic acute bowel disease, a clinical context we are commonly faced with at out institution, which is a tertiary-care centre without an emergency department but a referral centre for IBD.24 Third, as the patients were grouped according to age, the spectrum of pathologies encountered was different in the two groups and direct comparison of the diagnostic performance of CE-MDCT was not always possible (Figures 1–3). As far as the age threshold chosen is concerned, although arbitrary, it was based on epidemiological data.2 Finally, we are aware that the amount of iodinated CM injected according to the standard protocol (Group B) is indeed higher (0.74 gI kg−1) than the recommended dose of 0.5–0.6 gI kg−1 of total body weight.18 However, it is close to the maximum dose of 0.75 gI kg−1 of lean body weight.

Conclusion

The results of the present study indicate that single-pass CE-MDCT can be safely and effectively performed in selected patients with non-traumatic acute bowel disease according to an LR-HC dose protocol, which showed the highest benefit to risk ratio according to the AHARA principle of CT imaging,1 with a similar diagnostic accuracy as a standard protocol but a significantly lower ED comparing favourably with the values delivered using iterative methods such as reconstruction algorithms. Further studies are needed to validate such an approach in a much larger and unselected series of patients and possibly expand it to other clinical contexts. Contributor Information Luigi Camera, Email: [email protected]. Immacolata Liccardo, Email: [email protected]. Federica Romano, Email: [email protected]. Raffaele Liuzzi, Email: [email protected]. Antonio Rispo, Email: [email protected]. Massimo Imbriaco, Email: [email protected]. Anna Testa, Email: [email protected]. Gaetano Luglio, Email: [email protected]. Simona De Fronzo, Email: [email protected]. Fabiana Castiglione, Email: [email protected]. Luigi Bucci, Email: [email protected]. Arturo Brunetti, Email: [email protected].

References

- 1.Thrall JH. Radiation exposure in CT scanning and risk: where are we? Radiology 2012; 264: 325–8. doi: https://doi.org/10.1148/radiol.12121137 [DOI] [PubMed] [Google Scholar] - 2.Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007; 357: 2277–84. doi: https://doi.org/10.1056/NEJMra072149 [DOI] [PubMed] [Google Scholar] - 3.Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, et al. Low-tube-voltage, high-tube-current multi-detector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience. Radiology 2010; 254: 145–53. doi: https://doi.org/10.1148/radiol.09090094 [DOI] [PubMed] [Google Scholar] - 4.Hough DM, Fletcher JC, Grant KL, Fidler JL, Yu L, Geske JR, et al. Lowering kilo-voltage to reduce radiation dose in contrast enhanced abdominal CT: initial assessment of a prototype automated kilo-voltage selection tool. AJR Am J Roentgenol 2012; 199: 1070–7. doi: https://doi.org/10.2214/AJR.12.8637 [DOI] [PubMed] [Google Scholar] - 5.Kidoh M, Nakaura T, Nakamura S, Oda S, Utsunomiya D, Sakay Y, et al. Low-dose abdominal CT: comparison of low tube voltage with moderate-level iterative reconstruction and standard tube voltage, low tube current with high-level iterative reconstruction. Clin Radiol 2013; 68: 1008–15. doi: https://doi.org/10.1016/j.crad.2013.04.008 [DOI] [PubMed] [Google Scholar] - 6.Guite KM, Hinshaw JL, Ranallo FN, Lindstrom MJ, Lee FT, Jr. Ionizing radiation in abdominal CT: unindicated multiphase scans are an important source of medically unnecessary exposure. J Am Coll Radiol 2011; 8: 756–61. doi: https://doi.org/10.1016/j.jacr.2011.05.011 [DOI] [PMC free article] [PubMed] [Google Scholar] - 7.Johnson PT, Fishman EK. Routine use of pre-contrast and delayed acquisitions in abdominal CT: time for change. Abdom Imaging 2013; 38: 215–23. doi: https://doi.org/10.1007/s00261-012-9964-5 [DOI] [PubMed] [Google Scholar] - 8.Hwang SH, You JS, Song MK, Choi JY, Kim MJ, Chung YE. Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction. Eur Radiol 2015; 25: 1048–58. doi: https://doi.org/10.1007/s00330-014-3481-6 [DOI] [PubMed] [Google Scholar] - 9.Watanabe H, Kanematsu M, Miyoshi T, Goshima S, Kondo H, Moriyama N, et al. Improvement of image quality of low radiation dose abdominal CT by increasing contrast enhancement. AJR Am J Roengenol 2010; 195: 986–92. doi: https://doi.org/10.2214/AJR.10.4456 [DOI] [PubMed] [Google Scholar] - 10.Falt T, Soderberg M, Horberg L, Carlgren I, Leander P. Seesaw balancing radiation dose and IV contrast dose: evaluation of a new abdominal CT protocol for reducing age-specific risk. AJR Am J Roengenol 2013; 200: 383–8. [DOI] [PubMed] [Google Scholar] - 11.Camera L, Romano F, Liccardo I, Liuzzi R, Imbriaco M, Mainenti PP, et al. Balancing radiation and contrast media dose in single-pass abdominal multidetector CT: prospective evaluation of image quality. Acad Radiol 2015; 22: 1419–26. doi: https://doi.org/10.1016/j.acra.2015.06.016 [DOI] [PubMed] [Google Scholar] - 12.Mangini M, Carrafiello G, Laganà D, Palma L, Novario R, Dionigi G, et al. Non traumatic acute bowel disease: differential diagnosis with 64-row MDCT. Emerg Radiol 2008; 15: 171–8. doi: https://doi.org/10.1007/s10140-007-0692-z [DOI] [PubMed] [Google Scholar] - 13.Fletcher JG. CT enterography technique: theme and variations. Abdom Imaging 2009; 34: 283–8. doi: https://doi.org/10.1007/s00261-008-9411-9 [DOI] [PubMed] [Google Scholar] - 14.Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010; 256: 32–61. doi: https://doi.org/10.1148/radiol.10090908 [DOI] [PubMed] [Google Scholar] - 15.van der Molen AJ, Thomsen HS, Morcos SK; Contrast Media Safety Committee, European Society of Urogenital Radiology (ESUR). Effect of iodinated contrast media on thyroid function in adults. Eur Radiol 2004; 14: 902–7. doi: https://doi.org/10.1007/s00330-004-2238-z [DOI] [PubMed] [Google Scholar] - 16.Coakley FV, Gould R, Yeh BM, Arenson RL. CT radiation dose: what can you do right now in your practice? AJR Am J Roengenol 2011; 196: 619–25. doi: https://doi.org/10.2214/AJR.10.5043 [DOI] [PubMed] [Google Scholar] - 17.Maldijan PD, Goldman AR. Reducing radiation dose in body CT: a primer on dose metrics and key CT technical parameters. AJR Am J Roentgenol 2013; 200: 741–7. doi: https://doi.org/10.2214/AJR.12.9768 [DOI] [PubMed] [Google Scholar] - 18.Kondo H, Kanematsu M, Goshima S, Watanabe H, Kawada H, Moriyama N, et al. Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight? Eur Radiol 2013; 23: 1855–61. doi: https://doi.org/10.1007/s00330-013-2808-z [DOI] [PubMed] [Google Scholar] - 19.Thomsen HS, Stacul F. CIN: can we forget it? Acta Radiol 2014; 55: 1027–30. doi: https://doi.org/10.1177/0284185114545153 [DOI] [PubMed] [Google Scholar] - 20.Amato E, Salomone I, Naso S, Bottari A, Gaeta M, Blandino A. Can contrast media increase organ doses in CT examinations? A clinical study. AJR Am J Roentgenol 2013; 200: 1288–93. doi: https://doi.org/10.2214/AJR.12.8958 [DOI] [PubMed] [Google Scholar] - 21.Itatani R, Oda S, Utsunomiya D, Funama Y, Honda K, Katahira K, et al. Reduction in radiation and contrast medium dose via optimization of low-kilovoltage CT protocols using a hybrid iterative reconstruction algorithm at 256-slice body CT: Phantom study and clinical correlation. Clin Radiol 2013; 268: 128–35. doi: https://doi.org/10.1016/j.crad.2012.10.014 [DOI] [PubMed] [Google Scholar] - 22.van Randen A, Laméris W, van Es HW, van Heesewijk HP, van Ramshorst B, Ten Hove W, et al. A comparison of the accuracy of ultrasound and computed tomography in common diagnoses causing acute abdominal pain. Eur Radiol 2011; 21: 1535–45. doi: https://doi.org/10.1007/s00330-011-2087-5 [DOI] [PMC free article] [PubMed] [Google Scholar] - 23.Priola AM, Priola SM, Volpicelli G, Giraudo MT, Martino V, Fava C, et al. Accuracy of 64-row multi-detector CT in the diagnosis of surgically treated acute abdomen. Clin Imaging 2013; 37: 902–7. doi: https://doi.org/10.1016/j.clinimag.2013.02.016 [DOI] [PubMed] [Google Scholar] - 24.Castiglione F, Diaferia M, Morace F, Labianca O, Meucci C, Cuomo A, et al. Risk factors for inflammatory bowel disease according to the “hygiene hypothesis”: a case-control, multi-centre, prospective study in Southern Italy. J Crohns Colitis 2012; 6: 324–9. doi: https://doi.org/10.1016/j.crohns.2011.09.003 [DOI] [PubMed] [Google Scholar] - 25.Kim DH, Carucci LR, Baker ME, Cash BD, Dillmann JR, Feig BW, et al. ACR appropriateness criteria Crohn disease. J Am Coll Radiol 2015; 12: 1048–57. doi: https://doi.org/10.1016/j.jacr.2015.07.005 [DOI] [PubMed] [Google Scholar] - 26.Kambadakone AR, Chaudhary NA, Desai GS, Nguyen DD, Kulkarni NM, Sahani DV. Low-dose MDCT and CT enterography of patients with Crohn disease: feasibility of adaptive statistical iterative reconstruction. AJR Am J Roentgenol 2011; 196: W743–52. doi: https://doi.org/10.2214/AJR.10.5303 [DOI] [PubMed] [Google Scholar] - 27.Kaza RK, Plat JF, Al-Hawary MM, Wasnik A, Liu PS, Pandya A. CT Enterography at 80 kVp with adaptive statistical iterative reconstruction versus at 120 kVp with standard reconstruction: image quality, diagnostic adequacy and dose reduction. AJR Am J Roentgenol 2012; 198: 1084–92. doi: https://doi.org/10.2214/AJR.11.6597 [DOI] [PubMed] [Google Scholar] - 28.Ippolito D, Lombardi S, Trattenero C, Taleo Franzesi C, Bonaffini PA, Sironi S. CT enterography: diagnostic value of 4th generation iterative reconstruction algorithm in low dose studies in comparison with standard dose protocol for follow-up of patients with Crohn's disease. Eur J Radiol 2016; 85: 268–73. doi: https://doi.org/10.1016/j.ejrad.2015.10.011 [DOI] [PubMed] [Google Scholar] - 29.Siddiki HA, Fidler JL, Fletcher JG, Burton SS, Huprich JE, Hough DM, et al. Prospective comparison of state-of-the-art MR and CT enterography in small bowel Crohn's disease. AJR Am J Roentgenol 2009; 193: 113–21. doi: https://doi.org/10.2214/AJR.08.2027 [DOI] [PubMed] [Google Scholar] - 30.Werner A, Diehl SJ, Farag-Soliman M, Duber C. Multi-slice CT in routine diagnosis of suspected acute left-sided colonic diverticulitis: a prospective study of 120 patients. Eur Radiol 2003; 13: 2596–603. doi: https://doi.org/10.1007/s00330-003-1887-7 [DOI] [PubMed] [Google Scholar] - 31.Stoker J, van Randen A, Lameris W, Boermeester MA. Imaging patients with acute abdominal pain. Radiology 2009; 253: 31–46. doi: https://doi.org/10.1148/radiol.2531090302 [DOI] [PubMed] [Google Scholar] - 32.Taourel P, Aufort S, Merigeaud S, Doyon FC, Hoquet MD, Delabrousse E. Imaging of ischemic colitis. Radiol Clin North Am 2008; 46: 909–24. doi: https://doi.org/10.1016/j.rcl.2008.06.003 [DOI] [PubMed] [Google Scholar] - 33.Faraoun SA, Boudjella Mel A, Debzi N, Benidir N, Afredj N, Guerrache Y, et al. Budd-Chiari syndrome: a prospective analysis of hepatic vein obstruction on ultrasonography, multidetector-row computed tomography and MR imaging. Abdom Imaging 2015; 40: 1500–9. doi: https://doi.org/10.1007/s00261-015-0380-5 [DOI] [PubMed] [Google Scholar] - 34.Rispo A, Sica M, Bucci L, Musto D, Camera L, Ciancia G, et al. Protein-loosing enteropathy in sclerosing mesenteritis. Eur Rev Med Pharmacol Sci 2015; 19: 477–80. [PubMed] [Google Scholar]

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

⚙ Ask this paper AI returns verbatim quotes from the full text · source: oa-html ⓘ

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

MeSH descriptors

Colonic Diseases Colonoscopy Multidetector Computed Tomography Acute Disease Adult Aged Colonic Diseases Colonoscopy Colonoscopy Dose-Response Relationship, Drug Female Humans Male Middle Aged Multidetector Computed Tomography Multidetector Computed Tomography Prospective Studies Radiation Dosage Sensitivity and Specificity Young Adult

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-10-11T09:27:45.537177+00:00
pubmed
last seen: 2026-10-08T21:18:51.237577+00:00
unpaywall
last seen: 2026-10-14T06:23:58.021457+00:00