A Comparison of Trueness and Precision of 9 Intra-Oral Digital Scanners and 4 Lab Digital Scanners

preprint OA: closed CC-BY-4.0
🔓 Open OA copy View at publisher

Abstract

(1) Background: The purpose of this study is to evaluate the full arch scan accuracy (precision and trueness) of nine digital intra-oral scanners and four lab scanners. Previous studies have compared the accuracy of some intra-oral scanners, but as this is a field of quickly developing technologies, a more up-to-date study was needed to assess the capabilities of currently available models.; (2) Methods: The present in vitro study compared nine different intraoral scanners (Omnicam 4.6; Omnicam 5.1; Primescan; CS 3600; Trios 3; Trios 4; Runyes; i500 and DL206) as well as four lab light scanners (Einscan SE; 300e; E2 and Ineos X5) to investigate the accuracy of each scanner by examining the overall trueness and precision. Ten aligned and cut scans from each of the intra-oral and lab scanners in the in vitro study were brought into CloudCompare. A comparison was made with the master STL using the CloudCompare 3D analysis best-fit algorithm. The results were recorded along with individual standard deviation and a colorimetric map of the deviation across the surface of the STL mesh; a comparison was made to the master STL, quantified at specific points. ; (3) Results: In the present study, the Primescan had the best overall trueness (17.3 ± 4.9). Followed by (in order of increasing deviation) the Trios 4 (20.8 ± 6.2), i500 (25.2 ± 7.3), CS3600 (26.9 ± 15.9), Trios 3 (27.7 ± 6.8), Runyes (47.2 ± 5.4), Omnicam 5.1 (55.1 ± 9.5), Omnicam 4.6 (57.5 ± 3.2) and Launca DL206 (58.5 ± 22.0). Regarding the lab light scanners, the Ineos X5 had the best overall trueness with (0.0 ± 1.9). Followed by (in order of increasing deviation) the 3Shape E2 (3.6 ± 2.2), Up3D 300E (12.8 ± 2.7), and Einscan SE (14.9 ± 9.5); (4) Conclusions: This study confirms that all current generations of intra-oral digital scanners can capture a reliable, reproducible full arch scan in dentate patients. Out of the intra-oral scanners tested, no scanner produced results significantly similar in trueness to the Ineos X5. However, the Primescan was the only one to be statistically of a similar level of trueness to the 3Shape E2 lab scanner. All scanners in the study had mean trueness of under 60-micron deviation. While this study can compare the scanning accuracy of this sample in a dentate arch, the scanning of a fully edentulous arch is more challenging. The accuracy of these scanners in edentulous cases should be examined in further studies.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-28T02:00:01.590549+00:00
License: CC-BY-4.0