Diffusion-based size determination of solute particles: a method adapted for postsynaptic proteins

preprint OA: closed CC-BY-4.0
📄 Open PDF Full text JSON View at publisher

Abstract

The postsynaptic density (PSD) is a complex, multi-layered protein network largely situated on the internal surface of the postsynaptic membrane. It is the first processing unit for incoming synaptic transmissions, and changes in its internal structure are associated with synaptic strength and plasticity. These structural changes are largely governed by multivalent interactions between its components. The in vitro characterization of such complexes requires unbiased methods that can be used to estimate the size of the emerging assemblies for systems with multiple possible stoichiometries. Here we present an experimental method for detecting specific PSD proteins as well as their complexes based on their diffusion in a microfluidic environment. The method requires a fluorescent labelling technique that does not disrupt the function of labelled proteins, a microfluidic device that can maintain laminar flow for protein solutions, a microscope that can record the fluorescent signal emitted by these solutions, and an analytic software package that can process the collected experimental data and convert them into approximate particle sizes. We demonstrate the applicability of our method on protein constructs of various postsynaptic proteins, including the multivalent assembly between GKAP and LC8.
Full text 1,527 characters · extracted from oa-doi-fallback · click to expand
Abstract The postsynaptic density (PSD) is a complex, multi-layered protein network largely situated on the internal surface of the postsynaptic membrane. It is the first processing unit for incoming synaptic transmissions, and changes in its internal structure are associated with synaptic strength and plasticity. These structural changes are largely governed by multivalent interactions between its components. The in vitro characterization of such complexes requires unbiased methods that can be used to estimate the size of the emerging assemblies for systems with multiple possible stoichiometries. Here we present an experimental method for detecting specific PSD proteins as well as their complexes based on their diffusion in a microfluidic environment. The method requires a fluorescent labelling technique that does not disrupt the function of labelled proteins, a microfluidic device that can maintain laminar flow for protein solutions, a microscope that can record the fluorescent signal emitted by these solutions, and an analytic software package that can process the collected experimental data and convert them into approximate particle sizes. We demonstrate the applicability of our method on protein constructs of various postsynaptic proteins, including the multivalent assembly between GKAP and LC8. Competing Interest Statement The authors have declared no competing interest. Footnotes Additional experiments have been included and the purpose of our work has been clarified in the introduction section.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-05-28T02:00:01.590549+00:00
License: CC-BY-4.0