Compressive axial-integrated planar scanning (CAPS) microscopy for high-speed volumetric imaging of cardiac dynamics

preprint OA: closed

Abstract

Investigating cardiac dynamics, including contractile function and intracardiac flow, requires volumetric imaging capable of resolving whole-organ events at micrometer resolution and millisecond timescales. However, the limited readout bandwidth of detectors imposes fundamental trade-offs among spatial sampling, field of view, and achievable volume rates. Here we introduce compressive axial-integrated planar scanning (CAPS) microscopy, a computational imaging framework that combines rapid light-sheet scanning, detection-side axial multiplexing with model-based reconstruction to enhance detector bandwidth utilization for high-speed volumetric imaging. Using widely accessible optical sensors and components, CAPS achieves cellular-scale resolving power across heart chambers at 200 volumes per second with an effective detector pixel rate of 5.82 GHz, representing a ∼15-fold increase in spatiotemporal throughput relative to uncompressed volumetric acquisition. Coordinated high-speed encoding and computational reconstruction further mitigate rolling-shutter distortions in CMOS sensors while preserving frame rate and intrinsic optical sectioning. We demonstrate that CAPS enables beat-resolved imaging of single-cell cardiomyocyte kinematics, chamber-scale contractile dynamics, and intracardiac hemodynamics in zebrafish larvae under both healthy and pharmacologically perturbed conditions. Collectively, these advances establish CAPS as a powerful framework for quantitative, in vivo characterization of coordinated and disrupted cardiac dynamics at cellular resolution, supporting high-speed volumetric interrogation of organ-level function and disease progression.
Full text 1,866 characters · extracted from oa-html · click to expand
Abstract Investigating cardiac dynamics, including contractile function and intracardiac flow, requires volumetric imaging capable of resolving whole-organ events at micrometer resolution and millisecond timescales. However, the limited readout bandwidth of detectors imposes fundamental trade-offs among spatial sampling, field of view, and achievable volume rates. Here we introduce compressive axial-integrated planar scanning (CAPS) microscopy, a computational imaging framework that combines rapid light-sheet scanning, detection-side axial multiplexing with model-based reconstruction to enhance detector bandwidth utilization for high-speed volumetric imaging. Using widely accessible optical sensors and components, CAPS achieves cellular-scale resolving power across heart chambers at 200 volumes per second with an effective detector pixel rate of 5.82 GHz, representing a ∼15-fold increase in spatiotemporal throughput relative to uncompressed volumetric acquisition. Coordinated high-speed encoding and computational reconstruction further mitigate rolling-shutter distortions in CMOS sensors while preserving frame rate and intrinsic optical sectioning. We demonstrate that CAPS enables beat-resolved imaging of single-cell cardiomyocyte kinematics, chamber-scale contractile dynamics, and intracardiac hemodynamics in zebrafish larvae under both healthy and pharmacologically perturbed conditions. Collectively, these advances establish CAPS as a powerful framework for quantitative, in vivo characterization of coordinated and disrupted cardiac dynamics at cellular resolution, supporting high-speed volumetric interrogation of organ-level function and disease progression. Full Text Availability The license terms selected by the author(s) for this preprint version do not permit archiving in PMC. The full text is available from the preprint server.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-06-13T06:42:57.164913+00:00