A novel approach for the extraction of nucleic acids using a hybrid paper-plastic device

preprint OA: closed
📄 Open PDF Full text JSON View at publisher
AI-generated deep summary by claude@2026-06, 2026-06-24 · read from full text

The paper developed and evaluated a low-cost, equipment-free hybrid paper–plastic microfluidic cassette for rapid extraction of nucleic acids (DNA and RNA) from biological samples, aiming to avoid the cost, time, and instrumentation required by conventional extraction methods. Using Klebsiella pneumoniae (DNA) and HeLa cells (RNA), the authors tested different filter paper or glass fiber substrates and multiple lysis buffer formulations, then quantified nucleic acids by Qubit fluorometry and assessed quality by gel electrophoresis and PCR. They report that certain combinations (LF1 with lysis buffers 2, 4, and 5) produced the highest-quality DNA and RNA with 260/280 ratios around 1.8 and 2.0, and nucleic acid yields comparable to commercial extraction kits, with extracts suitable for direct PCR. The study’s limitations include being demonstrated only on these two cell/source types rather than a broader range of clinical or disease-specific samples. The paper does not explicitly discuss endometriosis or adenomyosis; it was included in the corpus via a keyword match in the upstream search index.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

Nucleic acid–based diagnostics play a crucial role in early and accurate disease detection. However, conventional extraction approaches are expensive, time-consuming, and require complex instrumentation and skilled personnel, which restricts their use in resource-limited settings. To develop and evaluate a simple, low-cost, and equipment-free paper-based microfluidic cassette device for rapid extraction of nucleic acids (DNA and RNA) from biological samples. A paper–plastic cassette was fabricated by laminating filter paper or glass fiber substrates between thermally bonded plastic sheets. The system was tested using Klebsiella pneumoniae (DNA) and HeLa cells (RNA) with different lysis buffer formulations. Extracted nucleic acids were quantified using a Qubit fluorimeter and assessed by gel electrophoresis and PCR amplification. Results were compared with standard commercial extraction kits. Among tested substrates, LF1 combined with lysis buffers 2, 4, and 5 yielded the highest quality DNA and RNA with 260/280 absorbance ratios of approximately 1.8 (DNA) and 2.0 (RNA). The nucleic acid yields were comparable to commercial kits, and the extracted material was suitable for direct downstream applications, including PCR. The developed paper–plastic cassette enables rapid, affordable, and equipment-free extraction of nucleic acids. This platform shows strong potential for point-of-care molecular diagnostics, particularly in low-resource and decentralized healthcare settings.
Full text 1,582 characters · extracted from oa-doi-fallback · click to expand
Abstract Nucleic acid–based diagnostics play a crucial role in early and accurate disease detection. However, conventional extraction approaches are expensive, time-consuming, and require complex instrumentation and skilled personnel, which restricts their use in resource-limited settings. To develop and evaluate a simple, low-cost, and equipment-free paper-based microfluidic cassette device for rapid extraction of nucleic acids (DNA and RNA) from biological samples. A paper–plastic cassette was fabricated by laminating filter paper or glass fiber substrates between thermally bonded plastic sheets. The system was tested using Klebsiella pneumoniae (DNA) and HeLa cells (RNA) with different lysis buffer formulations. Extracted nucleic acids were quantified using a Qubit fluorimeter and assessed by gel electrophoresis and PCR amplification. Results were compared with standard commercial extraction kits. Among tested substrates, LF1 combined with lysis buffers 2, 4, and 5 yielded the highest quality DNA and RNA with 260/280 absorbance ratios of approximately 1.8 (DNA) and 2.0 (RNA). The nucleic acid yields were comparable to commercial kits, and the extracted material was suitable for direct downstream applications, including PCR. The developed paper–plastic cassette enables rapid, affordable, and equipment-free extraction of nucleic acids. This platform shows strong potential for point-of-care molecular diagnostics, particularly in low-resource and decentralized healthcare settings. Competing Interest Statement The authors have declared no competing interest.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-06-13T06:42:57.164913+00:00