Accuracy assessment of removable partial denture frameworks fabricated by selective laser melting using two different  workflows. A cross-over  Clinical Study.

preprint OA: closed CC-BY-4.0
📄 Open PDF Full text JSON View at publisher
AI-generated summary by claude@2026-07, 2026-07-15

A fully-digital workflow for fabricating selective laser melting RPD frameworks showed superior accuracy in key areas compared to a combined analog-digital workflow.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

AI-generated deep summary by claude@2026-07, 2026-07-15 · read from full text

This crossover clinical study evaluated the overall accuracy and component-level misfit of mandibular Kennedy class I cobalt-chromium removable partial denture (RPD) frameworks fabricated by selective laser melting (SLM) using two workflows: a combined analog-digital route (physical impressions → stone casts → lab scanner) versus a fully digital route (intraoral scan → STL). Twenty-four participants each received both types of frameworks designed in the same software (3Shape), with accuracy assessed by intra-oral digital superimposition and STL color-map analysis at rest and in specific areas (rest, proximal plate, lingual plate, and I-bar clasp terminal), using paired t-tests. The combined analog-digital workflow showed more gaps, especially in lingual and proximal plates, while the fully digital workflow was significantly superior for overall accuracy in multiple measured locations, though both were reported as clinically acceptable within study limitations. The paper does not explicitly discuss endometriosis or adenomyosis; it was included in the corpus via a keyword match in the upstream search index.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

Abstract Background: Rapid advancements in computer-aided design and computer-aided manufacturing (CAD-CAM) have opened new pathways in the fabrication of removable partial dentures (RPDs). Digital impression serves as the first step of (CAD-CAM) technique, which includes two methods for data acquisition: direct intraoral scanning or indirect extraoral scanning. RPD frameworks may be considered the definitive test of accuracy for a digital workflow. This cross-over clinical study aimed to evaluate the overall accuracy of various parts for mandibular metallic RPD frameworks made by selective laser melting (SLM) using fully-digital versus combined analog-digital workflows. Methods: This study was carried out on 24 participants with mandibular Kennedy class I arches. Each participant received two RPDs frameworks, one fabricated using a combined analog-digital workflow (Group I) and the other using a fully- digital workflow (Group II). In Group I, the analog steps involved taking physical impressions and creating stone casts followed by scanning the casts with a laboratory scanner to create virtual casts. In Group II, a definitive scan STL file was created using an intraoral digital scanner. Both groups used 3Shape software for digital design of the RPD framework, ensuring consistency by using the same design, and subsequent fabrication using selective laser melting (SLM). To evaluate the accuracy, STL data analysis was performed through intra-oral digital superimposition evaluation, a color map was assessed and overall accuracy and the misfit (distance between each framework component and the reference intra-oral scan STL file) were measured at rest, proximal plate, lingual plate and I-bar retentive clasp terminal areas. The Paired t-test was utilized for statistical analysis of the data. Results: In Group I: combined analog-digital workflow color map assessment revealed more gaps particularly in the lingual plate and proximal plate areas, whereas Group II: fully-digital workflow showed better accuracy. Regarding the overall accuracy in the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal, Group II was significantly superior to Group I (P= 0.0125, 0.0019, <0.001, <0.001, and 0.0119, respectively). Conclusions: Within the limitations of this study, both workflows resulted in frameworks with clinically acceptable accuracy. However, SLM RPD frameworks fabricated using the fully-digital workflow showed superior accuracy in key areas such as the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal areas, when compared to the combined analog-digital workflow. Trial registration: Retrospectively registered (NCT06412159) 03/05/2024.
Full text 107,805 characters · extracted from preprint-html · click to expand
Accuracy assessment of removable partial denture frameworks fabricated by selective laser melting using two different workflows. A cross-over Clinical Study. | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Research Article Accuracy assessment of removable partial denture frameworks fabricated by selective laser melting using two different workflows. A cross-over Clinical Study. Mohamed Elgamal, Abdallah Mohammed Ibrahim, Basem Tarek Fadl, and 1 more This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-5073463/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 28 May, 2025 Read the published version in BMC Oral Health → Version 1 posted 9 You are reading this latest preprint version Abstract Background: Rapid advancements in computer-aided design and computer-aided manufacturing (CAD-CAM) have opened new pathways in the fabrication of removable partial dentures (RPDs). Digital impression serves as the first step of (CAD-CAM) technique, which includes two methods for data acquisition: direct intraoral scanning or indirect extraoral scanning. RPD frameworks may be considered the definitive test of accuracy for a digital workflow. This cross-over clinical study aimed to evaluate the overall accuracy of various parts for mandibular metallic RPD frameworks made by selective laser melting (SLM) using fully-digital versus combined analog-digital workflows. Methods: This study was carried out on 24 participants with mandibular Kennedy class I arches. Each participant received two RPDs frameworks, one fabricated using a combined analog-digital workflow (Group I) and the other using a fully- digital workflow (Group II). In Group I, the analog steps involved taking physical impressions and creating stone casts followed by scanning the casts with a laboratory scanner to create virtual casts. In Group II, a definitive scan STL file was created using an intraoral digital scanner. Both groups used 3Shape software for digital design of the RPD framework, ensuring consistency by using the same design, and subsequent fabrication using selective laser melting (SLM). To evaluate the accuracy, STL data analysis was performed through intra-oral digital superimposition evaluation, a color map was assessed and overall accuracy and the misfit (distance between each framework component and the reference intra-oral scan STL file) were measured at rest, proximal plate, lingual plate and I-bar retentive clasp terminal areas. The Paired t-test was utilized for statistical analysis of the data. Results: In Group I: combined analog-digital workflow color map assessment revealed more gaps particularly in the lingual plate and proximal plate areas, whereas Group II: fully-digital workflow showed better accuracy. Regarding the overall accuracy in the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal, Group II was significantly superior to Group I (P= 0.0125, 0.0019, <0.001, <0.001, and 0.0119, respectively). Conclusions: Within the limitations of this study, both workflows resulted in frameworks with clinically acceptable accuracy. However, SLM RPD frameworks fabricated using the fully-digital workflow showed superior accuracy in key areas such as the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal areas, when compared to the combined analog-digital workflow. Trial registration: Retrospectively registered (NCT06412159) 03/05/2024. Selective laser melting Removable partial denture accuracy fully-digital workflow combined analog-digital workflow Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Background There are several treatment options to restore partially edentulous arches, including tooth and implants-supported restorations [1]. Despite the high success rates of implant treatments, removable partial dentures (RPDs) remain the treatment of choice for a large number of patients especially when patients have medical problems that may be associated with absolute contraindications to implant rehabilitation like recent myocardial infarction, valvular prosthesis surgery, immunosuppression, bleeding issues, active treatment of malignancy, drug abuse, psychiatric illness, as well as intravenous bisphosphonate or relative contraindications like adolescence, aging, osteoporosis, smoking, diabetes, radiation therapy and cardiovascular disease [2, 3]. RPDs are conventionally made using the lost wax method, which can result in an ill-fitting casting due to refractory cast distortion and wax pattern distortion [4]. Digital technologies have been recently utilized to fabricate RPDs aiming to minimize human error, save time, and reduce material usage [5, 6]. Additionally, recent data indicates that, in comparison to conventionally manufactured RPDs, RPDs fabricated with digital technology resulted in higher patient satisfaction [7]. Recent developments in computer-aided design and computer-aided manufacturing (CAD-CAM) have opened up new possibilities for fabricating RPD frameworks through both additive and subtractive methods directly from digital designs. Selective laser melting (SLM) are among ten additive manufacturing 3-dimensional (3D) printing techniques [8]. SLM is a process that uses high-power lasers to melt metal powders, fusing the powder particles into a solid layer. Titanium and cobalt-chromium alloy (Co- Cr) can be printed using this method to construct RPD frameworks [9, 10]. RPD frameworks fabricated using the SLM technology was found to yield clinically satisfactory results [11]. Moreover, it has been reported that SLM Co-Cr alloy frameworks exhibited superior mechanical and microstructural qualities compared to cast or milled RPD frameworks [12]. Furthermore, the alloy would be more resistant to distortion due to this manufacturing technique, which could result in a more advantageous distribution of occlusal force across the remaining teeth or supporting tissues [13]. Creating a digital model of the intraoral hard and soft tissues is part of the standard digital workflow. For a fully-digital workflow, it can be done directly by using an intraoral scanner. Alternatively, for a combined analog-digital workflow, it can be done by scanning the stone cast itself using a laboratory scanner [14, 15]. Regarding the accuracy of intraoral digital scans of partially edentulous arches, the literature is inconsistent. For teeth in partially dentate arches the literature generally indicates that digital scans are as accurate as conventional impressions [16]. Moreover recent research has demonstrated that digital scans incorporating intra-oral scans (IOSs) are significantly more accurate than impressions made of silicone for partially edentulous arches [16–18]. Conversely, some research has found that scanning edentulous tissue is more challenging and less accurate than scanning hard tissue [19, 20]. It should be noted that soft tissues can depress up to 300 µm below the distal extension of a RPD so, high accuracy is not crucial in edentulous regions, however the potential for soft tissue displacement and the risk of decubitus must be considered [19]. Proper accuracy of RPD frameworks is crucial for the success of such restorations [21]. With the advent of new digital technologies, new assessment methods for the accuracy of an RPD framework are being possible as these techniques can measure 3D discrepancies directly, like digital superimposition, without the need for an intermediary substrate [22]. Additionally, the color mapping features in these new technologies provides important general data about the accuracy and adaptability of these restorations [20, 23, 24]. There is still much debate in the literature regarding the accuracy of fully- digital RPD frameworks compared to combined analog-digital workflows. While digitally created frameworks have shown to meet clinical requirements, the results of accuracy vary between studies due to differences in assessment techniques. However, there has been no research to directly compare the accuracy of fully-digital RPD frameworks with hybrid analog-digital fabrication workflows. The aim of this study was to use STL data analysis and intra-oral digital superimposition evaluation to assess overall accuracy of fully-digital versus combined analog-digital workflows, as well as the accuracy of each component of the RPD framework. The null hypothesis is that there would be no significant differences in the accuracy of RPD frameworks fabricated using the two workflows. Materials and methods Study design In this crossover study, each participant received two cobalt chromium SLM RPD frameworks using two different workflows. The standardization of variables that affect results was made possible by this design, as each participant was his own control. The first workflow was a combined analog-digital workflow (group I), while the second was a fully-digital one (group II). The same lab technician used the same machinery and followed the same procedures for fabricating all SLM RPD frameworks. To compare the two frameworks, the following parameters were assessed using intra-oral digital superimposition technology: 1) overall accuracy, and 2) accuracy of specific components such as occlusal rests, proximal plate, lingual plate, and retentive terminal of I-bar clasp. Sample size calculation A computer software program (G*power version 3.1.5; Heinrich Heine University Düsseldorf) was used to calculate the sample size through a power analysis. The computations were based on data from a previous study [25]. This study found a significant difference in accuracy between the major connectors of RPDs obtained from extraoral and intraoral digital impressions. The sample size was determined to be 24 participants [Pooled SD = 8.52, Effect size = 0.42, type I error (α) = 0.05, type II error (β) = 0.80]. The Ethics Committee of the faculty reviewed and approved the study (KFSIRB200-130) which was also registered on Clinical Trials.gov (NCT06412159), and complied with the Consolidated Standards of Reporting Trials (CONSORT) recommendations for clinical trials. Participants were informed about the study and provided their consent by signing an informed consent form. Inclusion Criteria : Twenty-four partially edentulous participants between the ages of 50 and 65 were included from the outpatient clinic of the Prosthodontic Department at the Faculty of Dentistry. The inclusion criteria for this study were as follows: Mandibular arches with bilateral distal extension areas (classified as Class I according to the Kennedy classification) Figure (1) , healthy and firm mucosa covering the ridges, remaining periodontally healthy teeth with no mobility including the first premolars on both sides which was opposed by either maxillary natural teeth or fixed restorations. Vestibular depth had to be sufficient to allow the I-bar clasp to be kept 3 mm away from the gingival margin. Fabrication of RPD frameworks: For all participants, cingulum rest seats on canines, mesial saucer shaped occlusal rests and distal guiding planes of 1.5 mm height were prepared in the mandibular first premolars. For group I (combined analog-digital workflow), mandibular primary irreversible hydrocolloid (C A 37 Superior Pink, Cavex, Holland bv) impression was recorded and poured in dental stone (Moldano, Bayer Dental D-5090 Lever Kusen). Custom tray was fabricated using light-cured acrylic material (Vertex Dental, Soesterberg, Netherlands) with a 3 mm spacer and four equally distributed stops. In the edentulous areas, border molding was accomplished using green modeling plastic impression compound (Green Stick Compound; Kerr Corp). The intaglio surface was coated with tray adhesive (VPS Tray adhesive, Kerr Corporation, Orange, CA, USA) and a physical definitive mandibular medium body polyvinyl siloxane (Zhermack INC., 45021 Badia, Polesine, Rovigo, Italy) impression was made and a stone cast was poured using Type IV stone (Silky-Rock; Whip Mix Corp). A laboratory scanner (3-shape D900 digital scanner) was then used to scan the cast and generate a virtual 3D master model. For group II (fully-digital workflow), a direct digital scan was made using an IOS (TRIOS 3; 3Shape) to create a definitive scan, that will serve as the reference scan STL file (RS-STL). To ensure high-quality IOS, specific precautions were taken to control moisture effectively by suction devices, or air-drying techniques to ensure the scanning area were dry and free of moisture before and during the scan. Special attention was given to dry the rest seats effectively before scanning by a gentle blotting with sterile gauze, cleaning the surfaces and scan powder was applied to improve the contrast. The scanning strategy (T-R) described by Chang et al [26] was followed, starting from the dentate area and moving to the edentulous region. The edentulous region posteriorly was then scanned in a zig-zag pattern after the dentate area, while keeping a distance of 10.0 mm between the tip of the scanner and the area to be recorded, as recommended by Rotar et al [27] for achieving the most accurate results. The same participant STL files were uploaded to the CAD software (3Shape Dental System; 3 Shape A/S, Copenhagen, Denmark) for both workflows. This allowed for the digital design of the RPD framework (the same design was used for consistency), which included a lingual plate mandibular major connector, meshworks on both edentulous ridges, a distal proximal plate, a mesial occlusal rest and I-bar retentive clasp arms on the mandibular first premolars. That was followed by exporting and sending the digital RPD framework designs to be SLM (NCL-M2150X; Nanjing Chamlion Laser Technology Co., Nanjing, China) formed in Co-Cr alloy (EOS Cobalt Chrome SP2; EOS GmbH). After printing, SLM frameworks were finished by sandblasting and diamond burs and subsequently polished with silicone rubber cups before being tried in the participant's mouth. Finishing and polishing were done by the same dental technician Figure (2 A& B) During try in a structured clinical assessment was followed, where RPD frameworks was inspected clinically by mirror and explored, when rest seats are correctly seated, the metallic parts adapt properly on the teeth, and the soft tissues are not impinged on by any part of the RPD considered a well fitted. Then the framworks seating, retention, and stability was assessed in the oral cavity to ensure that no significant discrepancies were present. Assessment using the 3 Scans Technique The accuracy for each framework in both groups was evaluated using intra-oral digital superimposition, utilizing the 3 scans technique [22, 28]. First scan: An intraoral scan without the framework (RS-STL). Second scan: An intraoral scan with the framework seated inside the participant’s mouth to help in the future alignment of the scans. Third scan: An extra oral scan of the framework alone using intraoral scanner, both polished and fitting surfaces of the framework were captured outside the participant’s mouth producing (TS-STL) file. Figures (3 A, B& C) . During the third scan the framework was fixed to the scanning table using two pieces of plasticine attached to the lower border of the lingual plate, and the scanning procedure was performed from various angles to obtain both the fitting surface and the polished surface of the framework. Furthermore, reflective surfaces of the RPD frameworks were managed using scan powder to minimize scanning errors due to surface reflectivity. An even, thin layer of powder was applied to all metal objects, furthermore excess powder or residue left carefully wiped away to avoid any inaccuracies on the scanning process. The TS-STL file was superimposed over the RS-STL file using the automatic alignment tool in the software (Medit Compare v1.1.1.61, Medit, Seoul, Republic of Korea) Figure (4) . Once the three scans were accurately aligned, the second scan was excluded and the gaps were measured vertically between the first and third scan to conduct the accuracy assessments [22]. Color map evaluation The color maps in Figure (5) show the differences in surface matching between the frameworks from each group and the reference scan. A close accuracy between the framework and the tooth structure would result in a green color, while blue areas indicate excessive contacts, yellow to orange areas indicate gaps but within acceptable accuracy, and red areas mean more gaps between the framework and the RS-STL file indicate an unacceptable accuracy. Accuracy measurements The accuracy of measurement was evaluated using a non-metrology grade Medit software program. Both the overall accuracy as well as the misfit in certain areas (the rest/rest seat areas of premolars using the cross sectional measurements, the right and left guide plane/plate area, the superior border of the lingual plate area, and retentive terminal of I-bar clasp were assessed. Figures (6, 7 & 8) All measurements were conducted by the same investigator and repeated five times to ensure reliability. The average measurement error was found to be approximately 0.002 mm. In evaluating the misfit, we considered a distance of 0 to 0.05 mm to indicate close contact with no gap, and a distance of 0.05 to 0.31 mm to be an acceptable accuracy from a clinical standpoint. All gaps greater than 0.31 mm would, therefore, be deemed clinically unacceptable. [29–31] Statistical analysis Data were tabulated and statistical analysis was performed on the data using SPSS software (SPSS v25, Inc., Chicago, IL). The data are displayed as the mean and standard deviation (SD), and Paired t-test was employed. The overall accuracy as well as the accuracy of each area was compared in this analysis. Statistical significance was determined by considering P < 0.05. Results Color map evaluation Regarding the visual analysis of the color map, the results showed a higher amount of spaced areas (indicated by the yellow color) in Group I: combined analog-digital workflow, particularly in the proximal plate and lingual plate areas. This suggests that there was more space between the scanned fitting surface and the RS-STL file, indicating that the frameworks were not fully adapted on the tissues intraorally. In contrast, Group II: fully-digital workflow displayed a more distribution of green color on the map, indicating that the frameworks were more adapted on the tissues intraorally. Accuracy measurements In terms of evaluating the accuracy, the distances between each framework and the reference scan were measured in millimeters (mm) for each framework in each group. The overall mean distance (gap) between the frameworks and the reference scans was significantly greater in Group I than in Group II. Table (1), Figure (9) Table 2 presents additional measurements taken between the frameworks and the reference scan for each participant in specific areas, including occlusal rests, proximal plates, the lingual plate major connector and I-bar clasp arm terminals. The mean distance (gap) between the frameworks and the reference scans was significantly higher in Group I than in Group II for all specified areas: the rest areas, the proximal plates, the lingual plate area, as well as the I-bar clasp arm terminal area Table (2), Figure (10) Table 1 Comparison of the overall mean accuracy (mm) for all frameworks of each group. Component Group I: (combined analog-digital workflow) (Mean ± SD) Group II: (fully-digital workflow) (Mean ± SD) t -test P value Overall mean accuracy 0.112 ± 0.018 0.101 ± 0.013 2.5683 0.0125* (Paired t-test, P < 0.05) *P is significant at 5% level. Table 2 Comparison of mean accuracy (mm) under occlusal rest, proximal plate, lingual plate major connector and terminal end of I-bar clasp retentive arm for each group. Component Group I: (combined analog-digital workflow) (Mean ± SD) Group II: (fully-digital workflow) (Mean ± SD) t- test P value Rest area accuracy 0.104 ± 0.007 0.098 ± 0.006 3.7974 0.0019* Proximal plate area accuracy 0.099 ± 0.008 0.085 ± 0.008 6.8560 < 0.001* Lingual plate area accuracy 0.134 ± 0.012 0.119 ± 0.007 5.6748 < 0.001* Terminal end of I-bar clasp retentive arm 0.109 ± 0.013 0.101 ± 0.009 2.5974 0.0119* (Paired t-test, P < 0.05) *P is significant at 5% level. Discussion In this study, the null hypothesis was rejected as the frameworks constructed following the fully-digital workflow exhibited significantly better accuracy values than those fabricated following the combined analog-digital workflow. RPDs may be considered the definitive assessment test of accuracy for a digital workflow as the fabrication of the RPD framework necessitates precise capture of both hard and soft tissue anatomy. Close adaptation and the relationship between the different RPD components and their supporting abutment teeth are critical not only for their effectiveness, but more importantly to minimize any adverse effects on the supporting abutments and avoid any patient discomfort. Moreover, any gaps between the prosthesis and mucosa may create possible plaque-retentive food traps that may promote tissue inflammation. [22] In the current study, visual assessment of the color map was used to evaluate the accuracy to determine the clinical value of two different workflows for fabricating SLM RPD frameworks. Overall, the mean accuracy results were considered acceptable for both workflows, as all recorded values were less than 0.31 mm. [29–31]. This finding is consistent with the findings of previous studies. According to the study conducted by Gan et al., RPD major connectors fabricated using both the fully digital and the combined- conventional workflows demonstrated clinically acceptable adaptation [25]. Kattadiyil et al. [17] effectively created an RPD through the use of a digital workflow and it was clinically acceptable. Suzuki et al. [32] illustrated how an RPD made using TRIOS 3 to obtain the digital impression could achieve excellent adaptive accuracy. Schimmel et al. [33] pointed out that whatever the degree of experience of the clinician, newer versions of IOS scanners might be appropriate for the creation of clinically acceptable RPD frameworks. Despite the limited number of clinical trials about the use of IOS and digital workflow in the fabrication of RPD frameworks, these studies justify our results as they reinforce the claim that the accuracy of RPDs fabricated using a fully digital workflow was acceptable. It is worth mentioning however, that there was a significant difference in the accuracy between the two workflows. The overall mean accuracy values for the combined analog-digital workflow and the fully-digital workflow was 0.112 ± 0.018 mm and 0.101 ± 0.013 mm, respectively. This indicates that the fully-digital workflow resulted in frameworks with superior accuracy. In addition to the mean overall accuracy, the accuracy of the individually tested RPD framework components was also superior in the fully-digital workflow group as compared to the combined analog-digital workflow group. This may be attributed to the fact that the process of transitioning between analog and digital workflows can lead to a buildup of errors at each step [22, 23]. The weakest point in combined workflows for RPD fabrication is probably during the impression stage. One possible explanation for this is the accumulation of mistakes during the physical impression, pouring it into the stone, and scanning it into a digital cast. These three steps inherently contain errors that could result in noticeable discrepancies in a rigid RPD framework [36]. In line with our research, a clinical study conducted by Tregerman et al. [36] evaluated the effectiveness of three different fabrication methods for RPD frameworks: analog, combined analog-digital and fully-digital where each participant received three RPD frameworks using each of the three techniques. Their assessed was based on a subjective clinical evaluation using a yes/no questionnaire survey, not objective assessments that depended on actual accuracy measurements as used in the current study. However, despite this difference, their subjective results were consistent with the objective results of the current study, as the fully-digital workflow (including IOS, designing, and SLM printing) was significantly more effective than the other two workflows including the combined analogue-digital workflow. The authors attributed the high performance of the fully digital workflow to the greater accuracy of intraoral scanning compared to traditional impressions [36]. Tasaka et al. [23] also confirmed our results through an in vitro study comparing the accuracy of castable 3D-printed resin pattern frameworks (a combination of analog and digital workflow) and SLS metal printed frameworks (a fully-digital workflow). The study reported a significant difference in accuracy at the rests, proximal plates, connectors, and clasp arms, with more discrepancy in the combined workflow compared to the fully digital SLS printed group. Furthermore, recent in vitro studies, have suggested that completely digitally fabricated RPD frameworks have superior accuracy compared to purely analog or combined analog-digital workflows. [23, 37, 38] However, these in vitro studies have several limitations, including the lack of consideration for environmental factors such as saliva, blood, and soft tissue changes. On the contrary, a study conducted by Gan et al. [25] compared the adaptation of RPD major connectors fabricated from intraoral and extraoral digital impressions using printed resin frameworks. They found that the adaptation of maxillary major connectors fabricated from intraoral digital impressions was inferior to those fabricated from extraoral digital impressions. This difference may be related to the different assessment methodology they used. They assessed adaptation intraorally and palatally only using light body silicone impression materials. Another in vitro study conducted by Korkes et al.,[39] on a Kennedy class III modification 1 partially edentulous mandibular arch cast, aimed to evaluate the seating accuracy of RPD frameworks fabricated using two digital workflows. Unlike our study, the marginal gap was assessed using an optical traveling microscope and the results showed that the combined analog-digital workflow group had the most superior accuracy, followed by the fully digital workflow group, with the conventional workflow group showing the least accuracy. The difference between their study and the current study, maybe related to the Kennedy Class and complexity of the frameworks. Frameworks in the current study had different dimensions with less components and a simpler design as there were no modification areas. One limitation of this study is that it only included cases with a mandibular Kennedy class I design. Future studies could expand the scope by including more complex cases, such as Kennedy class III or Class II designs with modification areas as they will include more RPD components, as well as cases with different edentulous span lengths. This could provide a more comprehensive understanding of accuracy of RPD frameworks of different designs. Another limitation is that the study measured the accuracy at only four locations of the RPD framework. This may not provide a comprehensive assessment of the accuracy in all areas including tissue-related areas. We recommend future studies evaluating soft tissue contact that could provide several advantages in assessing the overall accuracy of an RPD framework and would provide a more holistic assessment of framework accuracy. Other limitation of our study that direct accuracy validation of Medit Compare (non metrology-grade software) used in this specific workflow against other metrology-grade software was not performed. Additionally, it is important to note that the resolution of the scanner used can have an influential impact, potentially leading to measurement errors [40]. To overcome limitation of using single reference scan (RS-STL) in accuracy assessments, we recommend future studies using a cross-over design such as comparing the intraoral scan with the scans from the combined analog-digital workflow or superimposing the scanned RPDs from both methods on laboratory scans of conventional casts that could provide additional insights, help to minimize the potential bias introduced by using the same intraoral scan (RS-STL) as reference for both the accuracy evaluation and the fully-digital workflow. Therefore, it is important to consider these factors when interpreting the current results Conclusions Within the limitations of this study, it was found that both workflows resulted in frameworks with clinically acceptable accuracy. However, SLM RPD frameworks fabricated using the fully-digital workflow showed superior accuracy in key areas such as the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal areas, when compared to the combined analog-digital workflow. Abbreviations SLM selective laser melting RPD removable partial denture CAD-CAM computer-aided design and computer-aided manufacturing Co- Cr cobalt-chromium IOS intra-oral scanner 3D 3-dimensional RS-STL reference scan STL file TS-STL test scan STL file SD standard deviation Declarations Funding This research is self-funded. Open access publication is provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB). The present study was not funded, nor supported by any grant; therefore, the authors have no conflict of interest related to the present work. Author information Authors and Affiliations Department of Removable prosthodontics, Faculty of Dentistry, Mansoura University, #68 ElGomhoria Street, ElMansoura, P.O.Box: 35516, Eldakahlia, Egypt Mohamed Elgamal & Abdallah Mohammed Ibrahim, Department of Removable prosthodontics, Faculty of Dentistry, Horus University, Damietta, Egypt Mohamed Elgamal. Department of prosthodontics, Faculty of Dentistry, Kafrelsheikh University, Kafrelsheikh, Egypt Basem Tarek Fadl, Nourhan ahmed Ragheb. Contributions Elgamal.M., as the first and corresponding author, conceived the idea, prepared the manuscript and supervised all the procedures. Ibrahim.A.M. designed the study, collected the clinical data and performed the statistical analysis. Fadl B.T. performed all clinical procedures with participants and supervised lab work procedures. Ragheb.N.A. selected participants, drafted the manuscript and interpreted the data. All authors critically discussed the results, revised the manuscript, and approved the final version. Corresponding author Correspondence to Mohamed Elgamal Ethics declarations Ethics approval and consent to participate. The patients were fully informed about the purpose and procedures of this study and provided written informed consent. The study was approved by the local ethical committee of the Faculty of Dentistry, Kafrelsheikh University (KFSIRB200-130) and retrospectively registered at ClinicalTrials.gov (ClinicalTrials.gov Identifier: NCT06412159) (03/05/2024). Consent for publication Not applicable. Competing interests The authors declare no competing interests. References Ali Z, Baker SR, Shahrbaf S,Martin N, Vettore MV. Oral health-related quality of life after prosthodontic treatment for patients with partial edentulism: a systematic review and meta-analysis. J Prosthet Dent.2019;121:59–68. Hwang D, Wang HL. Medical contraindications to implant therapy: part I: absolute contraindications. Implant Dent. 2006;15(4):353-360. Hwang D, Wang HL. Medical contraindications to implant therapy: Part II: Relative contraindications. Implant Dent. 2007;16(1):13-23. Viswambaran M, Sundaram RK. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures. Contemp Clin Dent 2015;4:471-6. Lang LA, Tulunoglu I. A critically appraised topic review of computer aided design/computer-aided machining of removable partial denture frameworks. Dent Clin North Am. 2014;58:247–55 Barraclough O, Gray D, Ali Z, Nattress B. Modern partial dentures—part 1: novel manufacturing techniques. Br Dent J. 2021;230:651–57. Almufleh B, Arellanob A, Tamimi F. Patient-reported outcomes and framework fit accuracy of removable partial dentures fabricated using digital techniques: A systematic review and meta-analysis. J Prosthodont. 2024;33(7):626-636. Azari A, Nikzad S. The evolution of rapid prototyping in dentistry: a review. Rapid Prototyping Journal 2009;15:216-25. Hazeveld A, Huddleston Slater JJ, Ren Y. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofacial Orthop . 2014;145(1):108-115. Dawood A, Marti BM, Sauret-Jackson V, Darwood A. 3D printing in dentistry. Br Dent J 2015;219:521-9. Ye H, Ning J, Li M, Niu L, Yang J, Sun Y, et al. Preliminary clinical application of removable partial denture frameworks fabricated using computer-aided design and rapid prototyping techniques. Int J Prosthodont 2017;30:348-53. Zhou Y, Li N, Yan J, Zeng Q. Comparative analysis of the microstructures and mechanical properties of Co-Cr dental alloys fabricated by different methods. J Prosthet Dent 2018;120:617-23. Salim S, Salleh NM, Abidin ZZ, Yunus N, Rahmat R, Ibrahim N. Physicomechanical properties of cobalt-chromium removable partial denture palatal major connectors fabricated by selective laser melting. J Prosthet Dent . 2022;128:530.e1–530.e7. Renne W, Ludlow M, Fryml J, Schurch Z, Mennito A, Kessler R, et al. Evaluation of the accuracy of 7 digital scanners: an in vitro analysis based on 3-dimensional comparisons. J Prosthet Dent 2017;118:36-42. Sim JY, Jang Y, Kim WC, Kim HY, Lee DH, Kim JH. Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows. J Prosthodont Res . 2019;63(1):25-30. Hayama H, Fueki K, Wadachi J, Wakabayashi N. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible. J Prosthodont Res 2018;62:347-52. Kattadiyil MT, Mursic Z, AlRumaih H, Goodacre CJ. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent . 2014;112(3):444-448. Krahenbuhl JT, Cho SH, Irelan J, Bansal NK. Accuracy and precision of occlusal contacts of stereolithographic casts mounted by digital interocclusal registrations. J Prosthet Dent . 2016;116(2):231-236. Lytle RB. Soft tissue displacement beneath removable partial and complete dentures. J Prosthet Dent 1962;12:34-43. Müller P, Ender A, Joda T, Katsoulis J. Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner. Quintessence Int 2016;47:343-9. Frank, R.P.; Brudvik, J.S.; Leroux, B.; Milgrom, P.; Hawkins, N. Relationship between the standards of removable partial denture construction, clinical acceptability, and patient satisfaction. J. Prosthet. Dent. 2000; 83: 521–527. Rokhshad R, Tehrani AM, Nahidi R, Zarbakhsh A. Fit of removable partial denture frameworks fabricated from 3D printed patterns versus the conventional method: An in vitro comparison. J Prosthet Dent. 2024;131(6):1144-1149. Tasaka A, Shimizu T, Kato Y, et al. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering. J Prosthodont Res . 2020;64(2):224-230. Wu J, Cheng Y, Gao B, Yu H. A novel digital altered cast impression technique for fabricating a removable partial denture with a distal extension. J Am Dent Assoc . 2020;151(4):297-302. Gan N, Ruan Y, Sun J, Xiong Y, Jiao T. Comparison of Adaptation between the Major Connectors Fabricated from Intraoral Digital Impressions and Extraoral Digital Impressions. Sci Rep . 2018;8(1):529. Chang IC, Hung CC, Du JK, Liu CT, Lai PL, Lan TH. Accuracy of intraoral scanning methods for maxillary Kennedy class I arch. J Dent Sci . 2023;18(2):747-753. Rotar RN, Faur AB, Pop D, Jivanescu A. Scanning Distance Influence on the Intraoral Scanning Accuracy-An In Vitro Study. Materials (Basel). 2022;15(9):3061. Conceição P, Portugal J, Franco M, Alves NM, Marques D, Neves CB. Comparison between digital superimposition and microcomputed tomography methods of fit assessment of removable partial denture frameworks. J Prosthet Dent. 2024;131(3):479-486. Stern MA, Brudvik JS, Frank RP: Clinical evaluation of removable partial denture rest seat adaptation. J Prosthet Dent 1985;53:658-662. Eggbeer D, Bibb R, Williams R: The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks. Proc Inst Mech Eng 2005;219:195- 202. Soltanzadeh P, Suprono MS, Kattadiyil MT, Goodacre C, Gregorius W. An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks. J Prosthodont. 2019;28(5):547-555. Suzuki Y, Harada N, Watanabe KI, Maruo R, Shimpo H, Ohkubo C. Clinical application of an intraoral scanner and CAD/CAM system for a Kennedy class I partially edentulous patient. J Oral Sci . 2022;64(1):109-111. Schimmel M, Akino N, Srinivasan M, Wittneben JG, Yilmaz B, Abou-Ayash S. Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis. Clin Oral Investig . 2021;25(4):1839-1847. Wang X, Zhang F, Ma D, et al. Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison. Heliyon . 2024;10(10):e31063. Lee JH, Yun JH, Han JS, Yeo IL, Yoon HI. Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study. J Clin Med. 2019;8(8):1187. Tregerman I, Renne W, Kelly A, Wilson D. Evaluation of removable partial denture frameworks fabricated using 3 different techniques. J Prosthet Dent. 2019;122(4):390-395. Bajunaid SO, Altwaim B, Alhassan M, Alammari R. The Fit Accuracy of Removable Partial Denture Metal Frameworks Using Conventional and 3D Printed Techniques: An In Vitro Study. J Contemp Dent Pract. 2019;20(4):476-481. Ahmed N, Abbasi MS, Haider S, et al. Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review. Biomed Res Int . 2021;2021:3194433. Korkes A, Jomaa J, Kavouris A, et al. Seating accuracy of removable partial denture frameworks fabricated by different digital workflows in comparison to conventional workflow. J Prosthodont. Published online August 8, 2024. Conceição P, Portugal J, Neves CB. Evaluation of Removable Partial Denture Metal Frameworks Produced by Digital Methods—A Systematic Review. Applied Sciences. 2023; 13(19):10824. Alabdullah SA, Hannam AG, Wyatt CC, McCullagh APG, Aleksejuniene J, Mostafa NZ. Comparison of digital and conventional methods of fit evaluation of partial removable dental prosthesis frameworks fabricated by selective laser melting. J Prosthet Dent . 2022;127(3):478.e1-478.e10. Additional Declarations No competing interests reported. Cite Share Download PDF Status: Published Journal Publication published 28 May, 2025 Read the published version in BMC Oral Health → Version 1 posted Editorial decision: Revision requested 15 May, 2025 Editor assigned by journal 15 May, 2025 Reviews received at journal 13 May, 2025 Reviewers agreed at journal 08 May, 2025 Reviews received at journal 04 May, 2025 Reviewers agreed at journal 04 May, 2025 Reviewers invited by journal 02 May, 2025 Submission checks completed at journal 02 May, 2025 First submitted to journal 24 Apr, 2025 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-5073463","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Research Article","associatedPublications":[],"authors":[{"id":447293737,"identity":"057b5b66-c658-4f3d-8d87-e405b2327010","order_by":0,"name":"Mohamed Elgamal","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAA+0lEQVRIie2PsYrCQBCGZwlsms1eu2FFXyFi6cm9ygbBTrgHOLiAsOVZ+xZCIHXCgtfEqwNbpbZRFBEMchFBDzxWS8H9mhl+5pthACyWRyQFlB4rdaNzclM5zWCSXpI7FSbuVKhWabb5SFrYX4Tr9wqatBCo3BgU/2cgVGOm25IPYz6R0PEL4XQaBiXISaAY1qhWptyLIJwWAnNmVF6Wih30m/Tn8Z5U8Fkr7t6sEMhWUoeSeQknGERQX0FL0y85DhT60n1JhknXk6w9ycsRNxhAc6csd1vdG7vzWJPqtUW/+9lqZ3JqHHLpj0+g6G/yL+hq53VisVgsz8wvKJFVYs0hVIsAAAAASUVORK5CYII=","orcid":"","institution":"Mansoura University","correspondingAuthor":true,"prefix":"","firstName":"Mohamed","middleName":"","lastName":"Elgamal","suffix":""},{"id":447293738,"identity":"5f3973a4-8f77-4819-b310-21f73ba98309","order_by":1,"name":"Abdallah Mohammed Ibrahim","email":"","orcid":"","institution":"Mansoura University","correspondingAuthor":false,"prefix":"","firstName":"Abdallah","middleName":"Mohammed","lastName":"Ibrahim","suffix":""},{"id":447293739,"identity":"a17219d1-1f67-4fc2-acd5-658c90b59efb","order_by":2,"name":"Basem Tarek Fadl","email":"","orcid":"","institution":"Kafrelsheikh University","correspondingAuthor":false,"prefix":"","firstName":"Basem","middleName":"Tarek","lastName":"Fadl","suffix":""},{"id":447293740,"identity":"e2212cd1-aca8-4195-9439-90411c67bc71","order_by":3,"name":"Nourhan Ahmed Ragheb","email":"","orcid":"","institution":"Kafrelsheikh University","correspondingAuthor":false,"prefix":"","firstName":"Nourhan","middleName":"Ahmed","lastName":"Ragheb","suffix":""}],"badges":[],"createdAt":"2024-09-11 20:44:31","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-5073463/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-5073463/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1186/s12903-025-06214-9","type":"published","date":"2025-05-28T15:57:08+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":82032054,"identity":"cf25d497-cc8d-40a8-af4d-a8d37bc1140a","added_by":"auto","created_at":"2025-05-06 07:26:11","extension":"jpg","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":283690,"visible":true,"origin":"","legend":"\u003cp\u003eMandibular arch with bilateral distal extension areas with the first premolars as the last standing abutments.\u003c/p\u003e","description":"","filename":"Figure1.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/73f0d3d449b642082848a92d.jpg"},{"id":82028605,"identity":"d10838d4-b489-4ae8-9840-183ebeeda08e","added_by":"auto","created_at":"2025-05-06 07:02:10","extension":"jpg","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":83829,"visible":true,"origin":"","legend":"\u003cp\u003eSLM Framework. A-Extra-oral after finishing and polishing steps.\u003c/p\u003e","description":"","filename":"2.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/76dd49932b1a36daac2d8f6e.jpg"},{"id":82027905,"identity":"6b6b3510-c3c1-4f17-927b-9f79dc59c1dc","added_by":"auto","created_at":"2025-05-06 06:54:10","extension":"jpg","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":46165,"visible":true,"origin":"","legend":"\u003cp\u003eThe STL files for the reference scan and the test scan were uploaded into Medit Compare software.\u003c/p\u003e\n\u003cp\u003eA- STL file of the intraoral scan without the framework (RS-STL) (1-st scan)\u003c/p\u003e\n\u003cp\u003eB- STL file of the intraoral scan with the seated framework (2-nd scan)\u003c/p\u003e\n\u003cp\u003eC- STL file of the extraoral scan of the framework alone (TS-STL) (3-rd scan).\u003c/p\u003e","description":"","filename":"3.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/004e483e3a3ac5933a0fcd20.jpg"},{"id":82029755,"identity":"c1f5e190-ddf5-4807-8ecd-99c4eb74882b","added_by":"auto","created_at":"2025-05-06 07:10:10","extension":"jpg","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":89308,"visible":true,"origin":"","legend":"\u003cp\u003eAutomatic alignment was used to align STL files. The arrow indicates the tool to be used for the alignment of the reference and test scan STL files.\u003c/p\u003e","description":"","filename":"Figure4.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/acee160b5bfffe517bbd8c51.jpg"},{"id":82028610,"identity":"d75e98f0-a181-4455-885f-30d71d1115e1","added_by":"auto","created_at":"2025-05-06 07:02:11","extension":"jpg","order_by":5,"title":"Figure 5","display":"","copyAsset":false,"role":"figure","size":63023,"visible":true,"origin":"","legend":"\u003cp\u003eColor maps representative samples of the accuracy generated by the superimposition of TS-STL file over the RS-STL. (A) framework for Group I: combined analog-digital workflow. (B) framework for Group II: fully-digital workflow.\u003c/p\u003e","description":"","filename":"5.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/746bbedd5ae924891a8d8ae7.jpg"},{"id":82030833,"identity":"52c8c229-e4ab-4359-858d-b6246acbeab1","added_by":"auto","created_at":"2025-05-06 07:18:10","extension":"jpg","order_by":6,"title":"Figure 6","display":"","copyAsset":false,"role":"figure","size":61543,"visible":true,"origin":"","legend":"\u003cp\u003eAfter digital superimposition, Medit Compare automatically calculates the accuracy measurement of specific areas throughout the entire framework and shows the distance between the RS-STL file made with an IOS and the TS -STL file. The arrow indicates the tool to be used for the measurement of distance between the two STL files.\u003c/p\u003e","description":"","filename":"Figure6.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/e69afa57247bcb97dc3b8f81.jpg"},{"id":82027910,"identity":"5c68fe93-efc6-4179-8e74-74efdb2c35fe","added_by":"auto","created_at":"2025-05-06 06:54:10","extension":"jpg","order_by":7,"title":"Figure 7","display":"","copyAsset":false,"role":"figure","size":67411,"visible":true,"origin":"","legend":"\u003cp\u003eMedit compare software used for gap measurement between the framework and the teeth, A- At proximal plate area B- At rest area C- 2D cross sectional gap measurement between the rest and rest seat area.\u003c/p\u003e","description":"","filename":"7.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/69dec3ce435649be859704a0.jpg"},{"id":82027914,"identity":"ada63980-4318-4cd6-9373-75f64155fb1e","added_by":"auto","created_at":"2025-05-06 06:54:11","extension":"jpg","order_by":8,"title":"Figure 8","display":"","copyAsset":false,"role":"figure","size":95832,"visible":true,"origin":"","legend":"\u003cp\u003eDigital superimposition and measurement the accuracy of specific areas throughout the whole framework and shows the distance between the RS-STL file made with an IOS and the TS- STL file. The arrow indicates the tool to be used for the measurement of distance between the two STL files.\u003c/p\u003e","description":"","filename":"Figure8.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/6465edcd5572d046b77bd77d.jpg"},{"id":82028607,"identity":"fc06c921-8278-4b38-bc42-f6761e51e994","added_by":"auto","created_at":"2025-05-06 07:02:10","extension":"jpg","order_by":9,"title":"Figure 9","display":"","copyAsset":false,"role":"figure","size":123764,"visible":true,"origin":"","legend":"\u003cp\u003eShowing measuredoverall mean accuracy (mm) of all frameworks for combined and fully-digital workflows.\u003c/p\u003e","description":"","filename":"9.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/44792917cf45c62b661d983c.jpg"},{"id":82027913,"identity":"c9edefdb-1442-48c9-89e4-7f5e8e73b4e6","added_by":"auto","created_at":"2025-05-06 06:54:11","extension":"jpg","order_by":10,"title":"Figure 10","display":"","copyAsset":false,"role":"figure","size":171516,"visible":true,"origin":"","legend":"\u003cp\u003eShowing measured\u003cstrong\u003e \u003c/strong\u003emean accuracy (mm) under occlusal rest, proximal plate, lingual plate major connector and terminal end of I-bar clasp retentive arm for combined and fully-digital workflows.\u003c/p\u003e","description":"","filename":"10.jpg","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/4a3643dfe8e95ea2d36a5ef8.jpg"},{"id":83783074,"identity":"b01588d7-d400-459b-91c5-27f549a149f2","added_by":"auto","created_at":"2025-06-02 16:10:33","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":2037399,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-5073463/v1/4e3d2ee1-6f91-44b0-b47c-ac7ab5b2fa03.pdf"}],"financialInterests":"No competing interests reported.","formattedTitle":"Accuracy assessment of removable partial denture frameworks fabricated by selective laser melting using two different workflows. A cross-over Clinical Study.","fulltext":[{"header":"Background","content":"\u003cp\u003eThere are several treatment options to restore partially edentulous arches, including tooth and implants-supported restorations [1]. Despite the high success rates of implant treatments, removable partial dentures (RPDs) remain the treatment of choice for a large number of patients especially when patients have medical problems that may be associated with absolute contraindications to implant rehabilitation like recent myocardial infarction, valvular prosthesis surgery, immunosuppression, bleeding issues, active treatment of malignancy, drug abuse, psychiatric illness, as well as intravenous bisphosphonate or relative contraindications like adolescence, aging, osteoporosis, smoking, diabetes, radiation therapy and cardiovascular disease [2, 3].\u003c/p\u003e \u003cp\u003eRPDs are conventionally made using the lost wax method, which can result in an ill-fitting casting due to refractory cast distortion and wax pattern distortion [4]. Digital technologies have been recently utilized to fabricate RPDs aiming to minimize human error, save time, and reduce material usage [5, 6]. Additionally, recent data indicates that, in comparison to conventionally manufactured RPDs, RPDs fabricated with digital technology resulted in higher patient satisfaction [7].\u003c/p\u003e \u003cp\u003eRecent developments in computer-aided design and computer-aided manufacturing (CAD-CAM) have opened up new possibilities for fabricating RPD frameworks through both additive and subtractive methods directly from digital designs. Selective laser melting (SLM) are among ten additive manufacturing 3-dimensional (3D) printing techniques [8]. SLM is a process that uses high-power lasers to melt metal powders, fusing the powder particles into a solid layer. Titanium and cobalt-chromium alloy (Co- Cr) can be printed using this method to construct RPD frameworks [9, 10]. RPD frameworks fabricated using the SLM technology was found to yield clinically satisfactory results [11]. Moreover, it has been reported that SLM Co-Cr alloy frameworks exhibited superior mechanical and microstructural qualities compared to cast or milled RPD frameworks [12]. Furthermore, the alloy would be more resistant to distortion due to this manufacturing technique, which could result in a more advantageous distribution of occlusal force across the remaining teeth or supporting tissues [13].\u003c/p\u003e \u003cp\u003eCreating a digital model of the intraoral hard and soft tissues is part of the standard digital workflow. For a fully-digital workflow, it can be done directly by using an intraoral scanner. Alternatively, for a combined analog-digital workflow, it can be done by scanning the stone cast itself using a laboratory scanner [14, 15].\u003c/p\u003e \u003cp\u003eRegarding the accuracy of intraoral digital scans of partially edentulous arches, the literature is inconsistent. For teeth in partially dentate arches the literature generally indicates that digital scans are as accurate as conventional impressions [16]. Moreover recent research has demonstrated that digital scans incorporating intra-oral scans (IOSs) are significantly more accurate than impressions made of silicone for partially edentulous arches [16\u0026ndash;18].\u003c/p\u003e \u003cp\u003eConversely, some research has found that scanning edentulous tissue is more challenging and less accurate than scanning hard tissue [19, 20]. It should be noted that soft tissues can depress up to 300 \u0026micro;m below the distal extension of a RPD so, high accuracy is not crucial in edentulous regions, however the potential for soft tissue displacement and the risk of decubitus must be considered [19].\u003c/p\u003e \u003cp\u003eProper accuracy of RPD frameworks is crucial for the success of such restorations [21]. With the advent of new digital technologies, new assessment methods for the accuracy of an RPD framework are being possible as these techniques can measure 3D discrepancies directly, like digital superimposition, without the need for an intermediary substrate [22]. Additionally, the color mapping features in these new technologies provides important general data about the accuracy and adaptability of these restorations [20, 23, 24].\u003c/p\u003e \u003cp\u003eThere is still much debate in the literature regarding the accuracy of fully- digital RPD frameworks compared to combined analog-digital workflows. While digitally created frameworks have shown to meet clinical requirements, the results of accuracy vary between studies due to differences in assessment techniques. However, there has been no research to directly compare the accuracy of fully-digital RPD frameworks with hybrid analog-digital fabrication workflows. The aim of this study was to use STL data analysis and intra-oral digital superimposition evaluation to assess overall accuracy of fully-digital versus combined analog-digital workflows, as well as the accuracy of each component of the RPD framework. The null hypothesis is that there would be no significant differences in the accuracy of RPD frameworks fabricated using the two workflows.\u003c/p\u003e"},{"header":"Materials and methods","content":"\u003cdiv id=\"Sec3\" class=\"Section2\"\u003e \u003ch2\u003eStudy design\u003c/h2\u003e \u003cp\u003eIn this crossover study, each participant received two cobalt chromium SLM RPD frameworks using two different workflows. The standardization of variables that affect results was made possible by this design, as each participant was his own control. The first workflow was a combined analog-digital workflow (group I), while the second was a fully-digital one (group II). The same lab technician used the same machinery and followed the same procedures for fabricating all SLM RPD frameworks. To compare the two frameworks, the following parameters were assessed using intra-oral digital superimposition technology: 1) overall accuracy, and 2) accuracy of specific components such as occlusal rests, proximal plate, lingual plate, and retentive terminal of I-bar clasp.\u003c/p\u003e \u003c/div\u003e\n\u003ch3\u003eSample size calculation\u003c/h3\u003e\n\u003cp\u003eA computer software program (G*power version 3.1.5; Heinrich Heine University D\u0026uuml;sseldorf) was used to calculate the sample size through a power analysis. The computations were based on data from a previous study [25]. This study found a significant difference in accuracy between the major connectors of RPDs obtained from extraoral and intraoral digital impressions. The sample size was determined to be 24 participants [Pooled SD\u0026thinsp;=\u0026thinsp;8.52, Effect size\u0026thinsp;=\u0026thinsp;0.42, type I error (α)\u0026thinsp;=\u0026thinsp;0.05, type II error (β)\u0026thinsp;=\u0026thinsp;0.80]. The Ethics Committee of the faculty reviewed and approved the study (KFSIRB200-130) which was also registered on Clinical Trials.gov (NCT06412159), and complied with the Consolidated Standards of Reporting Trials (CONSORT) recommendations for clinical trials. Participants were informed about the study and provided their consent by signing an informed consent form.\u003c/p\u003e \u003cp\u003e \u003cb\u003eInclusion Criteria\u003c/b\u003e: Twenty-four partially edentulous participants between the ages of 50 and 65 were included from the outpatient clinic of the Prosthodontic Department at the Faculty of Dentistry. The inclusion criteria for this study were as follows: Mandibular arches with bilateral distal extension areas (classified as Class I according to the Kennedy classification) \u003cb\u003eFigure (1)\u003c/b\u003e, healthy and firm mucosa covering the ridges, remaining periodontally healthy teeth with no mobility including the first premolars on both sides which was opposed by either maxillary natural teeth or fixed restorations. Vestibular depth had to be sufficient to allow the I-bar clasp to be kept 3 mm away from the gingival margin.\u003c/p\u003e\n\u003ch3\u003eFabrication of RPD frameworks:\u003c/h3\u003e\n\u003cp\u003eFor all participants, cingulum rest seats on canines, mesial saucer shaped occlusal rests and distal guiding planes of 1.5 mm height were prepared in the mandibular first premolars.\u003c/p\u003e \u003cp\u003eFor group I (combined analog-digital workflow), mandibular primary irreversible hydrocolloid (C A 37 Superior Pink, Cavex, Holland bv) impression was recorded and poured in dental stone (Moldano, Bayer Dental D-5090 Lever Kusen). Custom tray was fabricated using light-cured acrylic material (Vertex Dental, Soesterberg, Netherlands) with a 3 mm spacer and four equally distributed stops. In the edentulous areas, border molding was accomplished using green modeling plastic impression compound (Green Stick Compound; Kerr Corp). The intaglio surface was coated with tray adhesive (VPS Tray adhesive, Kerr Corporation, Orange, CA, USA) and a physical definitive mandibular medium body polyvinyl siloxane (Zhermack INC., 45021 Badia, Polesine, Rovigo, Italy) impression was made and a stone cast was poured using Type IV stone (Silky-Rock; Whip Mix Corp). A laboratory scanner (3-shape D900 digital scanner) was then used to scan the cast and generate a virtual 3D master model.\u003c/p\u003e \u003cp\u003eFor group II (fully-digital workflow), a direct digital scan was made using an IOS (TRIOS 3; 3Shape) to create a definitive scan, that will serve as the reference scan STL file (RS-STL). To ensure high-quality IOS, specific precautions were taken to control moisture effectively by suction devices, or air-drying techniques to ensure the scanning area were dry and free of moisture before and during the scan. Special attention was given to dry the rest seats effectively before scanning by a gentle blotting with sterile gauze, cleaning the surfaces and scan powder was applied to improve the contrast. The scanning strategy (T-R) described by Chang et al [26] was followed, starting from the dentate area and moving to the edentulous region. The edentulous region posteriorly was then scanned in a zig-zag pattern after the dentate area, while keeping a distance of 10.0 mm between the tip of the scanner and the area to be recorded, as recommended by Rotar et al [27] for achieving the most accurate results.\u003c/p\u003e \u003cp\u003eThe same participant STL files were uploaded to the CAD software (3Shape Dental System; 3 Shape A/S, Copenhagen, Denmark) for both workflows. This allowed for the digital design of the RPD framework (the same design was used for consistency), which included a lingual plate mandibular major connector, meshworks on both edentulous ridges, a distal proximal plate, a mesial occlusal rest and I-bar retentive clasp arms on the mandibular first premolars. That was followed by exporting and sending the digital RPD framework designs to be SLM (NCL-M2150X; Nanjing Chamlion Laser Technology Co., Nanjing, China) formed in Co-Cr alloy (EOS Cobalt Chrome SP2; EOS GmbH). After printing, SLM frameworks were finished by sandblasting and diamond burs and subsequently polished with silicone rubber cups before being tried in the participant's mouth. Finishing and polishing were done by the same dental technician \u003cb\u003eFigure (2 A\u0026amp; B)\u003c/b\u003e\u003c/p\u003e \u003cp\u003eDuring try in a structured clinical assessment was followed, where RPD frameworks was inspected clinically by mirror and explored, when rest seats are correctly seated, the metallic parts adapt properly on the teeth, and the soft tissues are not impinged on by any part of the RPD considered a well fitted. Then the framworks seating, retention, and stability was assessed in the oral cavity to ensure that no significant discrepancies were present.\u003c/p\u003e\n\u003ch3\u003eAssessment using the 3 Scans Technique\u003c/h3\u003e\n\u003cp\u003eThe accuracy for each framework in both groups was evaluated using intra-oral digital superimposition, utilizing the 3 scans technique [22, 28].\u003c/p\u003e \u003cp\u003eFirst scan: An intraoral scan without the framework (RS-STL). Second scan: An intraoral scan with the framework seated inside the participant\u0026rsquo;s mouth to help in the future alignment of the scans. Third scan: An extra oral scan of the framework alone using intraoral scanner, both polished and fitting surfaces of the framework were captured outside the participant\u0026rsquo;s mouth producing (TS-STL) file. Figures\u0026nbsp;(3\u003cb\u003eA, B\u0026amp; C)\u003c/b\u003e. During the third scan the framework was fixed to the scanning table using two pieces of plasticine attached to the lower border of the lingual plate, and the scanning procedure was performed from various angles to obtain both the fitting surface and the polished surface of the framework. Furthermore, reflective surfaces of the RPD frameworks were managed using scan powder to minimize scanning errors due to surface reflectivity. An even, thin layer of powder was applied to all metal objects, furthermore excess powder or residue left carefully wiped away to avoid any inaccuracies on the scanning process.\u003c/p\u003e \u003cp\u003eThe TS-STL file was superimposed over the RS-STL file using the automatic alignment tool in the software (Medit Compare v1.1.1.61, Medit, Seoul, Republic of Korea) \u003cb\u003eFigure (4)\u003c/b\u003e. Once the three scans were accurately aligned, the second scan was excluded and the gaps were measured vertically between the first and third scan to conduct the accuracy assessments [22].\u003c/p\u003e\n\u003ch3\u003eColor map evaluation\u003c/h3\u003e\n\u003cp\u003eThe color maps in \u003cb\u003eFigure (5)\u003c/b\u003e show the differences in surface matching between the frameworks from each group and the reference scan. A close accuracy between the framework and the tooth structure would result in a green color, while blue areas indicate excessive contacts, yellow to orange areas indicate gaps but within acceptable accuracy, and red areas mean more gaps between the framework and the RS-STL file indicate an unacceptable accuracy.\u003c/p\u003e \u003cdiv id=\"Sec8\" class=\"Section2\"\u003e \u003ch2\u003eAccuracy measurements\u003c/h2\u003e \u003cp\u003eThe accuracy of measurement was evaluated using a non-metrology grade Medit software program. Both the overall accuracy as well as the misfit in certain areas (the rest/rest seat areas of premolars using the cross sectional measurements, the right and left guide plane/plate area, the superior border of the lingual plate area, and retentive terminal of I-bar clasp were assessed. Figures\u0026nbsp;(6, \u003cb\u003e7 \u0026amp; 8)\u003c/b\u003e\u003c/p\u003e \u003cp\u003eAll measurements were conducted by the same investigator and repeated five times to ensure reliability. The average measurement error was found to be approximately 0.002 mm. In evaluating the misfit, we considered a distance of 0 to 0.05 mm to indicate close contact with no gap, and a distance of 0.05 to 0.31 mm to be an acceptable accuracy from a clinical standpoint. All gaps greater than 0.31 mm would, therefore, be deemed clinically unacceptable. [29\u0026ndash;31]\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec9\" class=\"Section2\"\u003e \u003ch2\u003eStatistical analysis\u003c/h2\u003e \u003cp\u003eData were tabulated and statistical analysis was performed on the data using SPSS software (SPSS v25, Inc., Chicago, IL). The data are displayed as the mean and standard deviation (SD), and Paired t-test was employed. The overall accuracy as well as the accuracy of each area was compared in this analysis. Statistical significance was determined by considering \u003cem\u003eP\u003c/em\u003e\u0026thinsp;\u0026lt;\u0026thinsp;0.05.\u003c/p\u003e \u003c/div\u003e"},{"header":"Results","content":"\u003cdiv id=\"Sec11\" class=\"Section2\"\u003e \u003ch2\u003eColor map evaluation\u003c/h2\u003e \u003cp\u003eRegarding the visual analysis of the color map, the results showed a higher amount of spaced areas (indicated by the yellow color) in Group I: combined analog-digital workflow, particularly in the proximal plate and lingual plate areas. This suggests that there was more space between the scanned fitting surface and the RS-STL file, indicating that the frameworks were not fully adapted on the tissues intraorally. In contrast, Group II: fully-digital workflow displayed a more distribution of green color on the map, indicating that the frameworks were more adapted on the tissues intraorally.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec12\" class=\"Section2\"\u003e \u003ch2\u003eAccuracy measurements\u003c/h2\u003e \u003cp\u003eIn terms of evaluating the accuracy, the distances between each framework and the reference scan were measured in millimeters (mm) for each framework in each group. The overall mean distance (gap) between the frameworks and the reference scans was significantly greater in Group I than in Group II. \u003cb\u003eTable\u0026nbsp;(1), Figure (9)\u003c/b\u003e\u003c/p\u003e \u003cp\u003eTable\u0026nbsp;\u003cspan refid=\"Tab4\" class=\"InternalRef\"\u003e2\u003c/span\u003e presents additional measurements taken between the frameworks and the reference scan for each participant in specific areas, including occlusal rests, proximal plates, the lingual plate major connector and I-bar clasp arm terminals. The mean distance (gap) between the frameworks and the reference scans was significantly higher in Group I than in Group II for all specified areas: the rest areas, the proximal plates, the lingual plate area, as well as the I-bar clasp arm terminal area \u003cb\u003eTable\u0026nbsp;(2), Figure (10)\u003c/b\u003e\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab1\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 1\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eComparison of the overall mean accuracy (mm) for all frameworks of each group.\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"5\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c5\" colnum=\"5\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e \u003cp\u003eComponent\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003eGroup I:\u003c/p\u003e \u003cp\u003e(combined analog-digital workflow)\u003c/p\u003e \u003cp\u003e(Mean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD)\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003eGroup II:\u003c/p\u003e \u003cp\u003e(fully-digital workflow)\u003c/p\u003e \u003cp\u003e(Mean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD)\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003e\u003cem\u003et\u003c/em\u003e-test\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c5\"\u003e \u003cp\u003e\u003cem\u003eP\u003c/em\u003e value\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003e\u003cb\u003eOverall mean accuracy\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e\u003cb\u003e0.112\u0026thinsp;\u0026plusmn;\u0026thinsp;0.018\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e\u003cb\u003e0.101\u0026thinsp;\u0026plusmn;\u0026thinsp;0.013\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e\u003cb\u003e2.5683\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e\u003cb\u003e0.0125*\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003ctfoot\u003e \u003ctr\u003e\u003ctd colspan=\"5\"\u003e\u003cb\u003e(Paired t-test, P\u0026thinsp;\u0026lt;\u0026thinsp;0.05) *P is significant at 5% level.\u003c/b\u003e\u003c/td\u003e\u003c/tr\u003e \u003c/tfoot\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab2\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 2\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eComparison of mean accuracy (mm) under occlusal rest, proximal plate, lingual plate major connector and terminal end of I-bar clasp retentive arm for each group.\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"5\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\"\u0026plusmn;\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\"\u0026plusmn;\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e \u003cdiv align=\"char\" char=\".\" class=\"colspec\" colname=\"c5\" colnum=\"5\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e \u003cp\u003eComponent\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003eGroup I:\u003c/p\u003e \u003cp\u003e(combined analog-digital workflow)\u003c/p\u003e \u003cp\u003e(Mean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD)\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003eGroup II:\u003c/p\u003e \u003cp\u003e(fully-digital workflow)\u003c/p\u003e \u003cp\u003e(Mean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD)\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003e\u003cem\u003et-\u003c/em\u003etest\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c5\"\u003e \u003cp\u003e\u003cem\u003eP\u003c/em\u003e value\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e \u003cp\u003eRest area accuracy\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003e0.104\u0026thinsp;\u0026plusmn;\u0026thinsp;0.007\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003e0.098\u0026thinsp;\u0026plusmn;\u0026thinsp;0.006\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003e3.7974\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c5\"\u003e \u003cp\u003e0.0019*\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e \u003cp\u003eProximal plate area accuracy\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003e0.099\u0026thinsp;\u0026plusmn;\u0026thinsp;0.008\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003e0.085\u0026thinsp;\u0026plusmn;\u0026thinsp;0.008\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003e6.8560\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c5\"\u003e \u003cp\u003e\u003cem\u003e\u0026lt;\u003c/em\u003e\u0026thinsp;0.001*\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003e\u003cb\u003eLingual plate area accuracy\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\"\u0026plusmn;\" colname=\"c2\"\u003e \u003cp\u003e\u003cb\u003e0.134\u0026thinsp;\u0026plusmn;\u0026thinsp;0.012\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\"\u0026plusmn;\" colname=\"c3\"\u003e \u003cp\u003e\u003cb\u003e0.119\u0026thinsp;\u0026plusmn;\u0026thinsp;0.007\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e \u003cp\u003e\u003cb\u003e5.6748\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c5\"\u003e \u003cp\u003e\u003cb\u003e\u0026lt;\u003c/b\u003e\u0026thinsp;\u003cb\u003e0.001*\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003e\u003cb\u003eTerminal end of I-bar clasp retentive arm\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\"\u0026plusmn;\" colname=\"c2\"\u003e \u003cp\u003e\u003cb\u003e0.109\u0026thinsp;\u0026plusmn;\u0026thinsp;0.013\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\"\u0026plusmn;\" colname=\"c3\"\u003e \u003cp\u003e\u003cb\u003e0.101\u0026thinsp;\u0026plusmn;\u0026thinsp;0.009\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c4\"\u003e \u003cp\u003e\u003cb\u003e2.5974\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"char\" char=\".\" colname=\"c5\"\u003e \u003cp\u003e\u003cb\u003e0.0119*\u003c/b\u003e\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003ctfoot\u003e \u003ctr\u003e\u003ctd colspan=\"5\"\u003e\u003cb\u003e(Paired t-test, P\u0026thinsp;\u0026lt;\u0026thinsp;0.05) *P is significant at 5% level.\u003c/b\u003e\u003c/td\u003e\u003c/tr\u003e \u003c/tfoot\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003c/div\u003e"},{"header":"Discussion","content":"\u003cp\u003eIn this study, the null hypothesis was rejected as the frameworks constructed following the fully-digital workflow exhibited significantly better accuracy values than those fabricated following the combined analog-digital workflow.\u003c/p\u003e \u003cp\u003eRPDs may be considered the definitive assessment test of accuracy for a digital workflow as the fabrication of the RPD framework necessitates precise capture of both hard and soft tissue anatomy. Close adaptation and the relationship between the different RPD components and their supporting abutment teeth are critical not only for their effectiveness, but more importantly to minimize any adverse effects on the supporting abutments and avoid any patient discomfort. Moreover, any gaps between the prosthesis and mucosa may create possible plaque-retentive food traps that may promote tissue inflammation. [22]\u003c/p\u003e \u003cp\u003eIn the current study, visual assessment of the color map was used to evaluate the accuracy to determine the clinical value of two different workflows for fabricating SLM RPD frameworks. Overall, the mean accuracy results were considered acceptable for both workflows, as all recorded values were less than 0.31 mm. [29\u0026ndash;31]. This finding is consistent with the findings of previous studies. According to the study conducted by Gan et al., RPD major connectors fabricated using both the fully digital and the combined- conventional workflows demonstrated clinically acceptable adaptation [25]. Kattadiyil et al. [17] effectively created an RPD through the use of a digital workflow and it was clinically acceptable. Suzuki et al. [32] illustrated how an RPD made using TRIOS 3 to obtain the digital impression could achieve excellent adaptive accuracy. Schimmel et al. [33] pointed out that whatever the degree of experience of the clinician, newer versions of IOS scanners might be appropriate for the creation of clinically acceptable RPD frameworks. Despite the limited number of clinical trials about the use of IOS and digital workflow in the fabrication of RPD frameworks, these studies justify our results as they reinforce the claim that the accuracy of RPDs fabricated using a fully digital workflow was acceptable.\u003c/p\u003e \u003cp\u003eIt is worth mentioning however, that there was a significant difference in the accuracy between the two workflows. The overall mean accuracy values for the combined analog-digital workflow and the fully-digital workflow was 0.112\u0026thinsp;\u0026plusmn;\u0026thinsp;0.018 mm and 0.101\u0026thinsp;\u0026plusmn;\u0026thinsp;0.013 mm, respectively. This indicates that the fully-digital workflow resulted in frameworks with superior accuracy. In addition to the mean overall accuracy, the accuracy of the individually tested RPD framework components was also superior in the fully-digital workflow group as compared to the combined analog-digital workflow group. This may be attributed to the fact that the process of transitioning between analog and digital workflows can lead to a buildup of errors at each step [22, 23]. The weakest point in combined workflows for RPD fabrication is probably during the impression stage. One possible explanation for this is the accumulation of mistakes during the physical impression, pouring it into the stone, and scanning it into a digital cast. These three steps inherently contain errors that could result in noticeable discrepancies in a rigid RPD framework [36].\u003c/p\u003e \u003cp\u003eIn line with our research, a clinical study conducted by Tregerman et al. [36] evaluated the effectiveness of three different fabrication methods for RPD frameworks: analog, combined analog-digital and fully-digital where each participant received three RPD frameworks using each of the three techniques. Their assessed was based on a subjective clinical evaluation using a yes/no questionnaire survey, not objective assessments that depended on actual accuracy measurements as used in the current study. However, despite this difference, their subjective results were consistent with the objective results of the current study, as the fully-digital workflow (including IOS, designing, and SLM printing) was significantly more effective than the other two workflows including the combined analogue-digital workflow. The authors attributed the high performance of the fully digital workflow to the greater accuracy of intraoral scanning compared to traditional impressions [36].\u003c/p\u003e \u003cp\u003eTasaka et al. [23] also confirmed our results through an in vitro study comparing the accuracy of castable 3D-printed resin pattern frameworks (a combination of analog and digital workflow) and SLS metal printed frameworks (a fully-digital workflow). The study reported a significant difference in accuracy at the rests, proximal plates, connectors, and clasp arms, with more discrepancy in the combined workflow compared to the fully digital SLS printed group. Furthermore, recent in vitro studies, have suggested that completely digitally fabricated RPD frameworks have superior accuracy compared to purely analog or combined analog-digital workflows. [23, 37, 38] However, these in vitro studies have several limitations, including the lack of consideration for environmental factors such as saliva, blood, and soft tissue changes.\u003c/p\u003e \u003cp\u003eOn the contrary, a study conducted by Gan et al. [25] compared the adaptation of RPD major connectors fabricated from intraoral and extraoral digital impressions using printed resin frameworks. They found that the adaptation of maxillary major connectors fabricated from intraoral digital impressions was inferior to those fabricated from extraoral digital impressions. This difference may be related to the different assessment methodology they used. They assessed adaptation intraorally and palatally only using light body silicone impression materials. Another in vitro study conducted by Korkes et al.,[39] on a Kennedy class III modification 1 partially edentulous mandibular arch cast, aimed to evaluate the seating accuracy of RPD frameworks fabricated using two digital workflows. Unlike our study, the marginal gap was assessed using an optical traveling microscope and the results showed that the combined analog-digital workflow group had the most superior accuracy, followed by the fully digital workflow group, with the conventional workflow group showing the least accuracy. The difference between their study and the current study, maybe related to the Kennedy Class and complexity of the frameworks. Frameworks in the current study had different dimensions with less components and a simpler design as there were no modification areas.\u003c/p\u003e \u003cp\u003eOne limitation of this study is that it only included cases with a mandibular Kennedy class I design. Future studies could expand the scope by including more complex cases, such as Kennedy class III or Class II designs with modification areas as they will include more RPD components, as well as cases with different edentulous span lengths. This could provide a more comprehensive understanding of accuracy of RPD frameworks of different designs. Another limitation is that the study measured the accuracy at only four locations of the RPD framework. This may not provide a comprehensive assessment of the accuracy in all areas including tissue-related areas. We recommend future studies evaluating soft tissue contact that could provide several advantages in assessing the overall accuracy of an RPD framework and would provide a more holistic assessment of framework accuracy.\u003c/p\u003e \u003cp\u003eOther limitation of our study that direct accuracy validation of Medit Compare (non metrology-grade software) used in this specific workflow against other metrology-grade software was not performed. Additionally, it is important to note that the resolution of the scanner used can have an influential impact, potentially leading to measurement errors [40]. To overcome limitation of using single reference scan (RS-STL) in accuracy assessments, we recommend future studies using a cross-over design such as comparing the intraoral scan with the scans from the combined analog-digital workflow or superimposing the scanned RPDs from both methods on laboratory scans of conventional casts that could provide additional insights, help to minimize the potential bias introduced by using the same intraoral scan (RS-STL) as reference for both the accuracy evaluation and the fully-digital workflow. Therefore, it is important to consider these factors when interpreting the current results\u003c/p\u003e"},{"header":"Conclusions","content":"\u003cp\u003eWithin the limitations of this study, it was found that both workflows resulted in frameworks with clinically acceptable accuracy. However, SLM RPD frameworks fabricated using the fully-digital workflow showed superior accuracy in key areas such as the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal areas, when compared to the combined analog-digital workflow.\u003c/p\u003e"},{"header":"Abbreviations","content":"\u003cp\u003eSLM \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;selective laser melting\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eRPD \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; removable partial denture\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eCAD-CAM \u0026nbsp; \u0026nbsp; computer-aided design and\u0026nbsp;computer-aided manufacturing\u003c/p\u003e\n\u003cp\u003eCo- Cr \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;cobalt-chromium\u0026nbsp;\u003c/p\u003e\n\u003cp\u003eIOS \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;intra-oral scanner\u003c/p\u003e\n\u003cp\u003e3D \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; 3-dimensional\u003c/p\u003e\n\u003cp\u003eRS-STL \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; reference scan STL file\u003c/p\u003e\n\u003cp\u003eTS-STL \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; test scan STL file\u003c/p\u003e\n\u003cp\u003eSD \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; standard deviation\u003c/p\u003e"},{"header":"Declarations","content":"\u003cp\u003e\u003cstrong\u003eFunding\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThis research is self-funded. Open access publication is provided by The Science, Technology \u0026amp; Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB). The present study was not funded, nor supported by any grant; therefore, the authors have no conflict of interest related to the present work.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor information\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eAuthors and Affiliations\u003c/p\u003e\n\u003col start=\"1\" type=\"1\"\u003e\n \u003cli\u003eDepartment of Removable prosthodontics, Faculty of Dentistry, Mansoura University, #68 ElGomhoria Street, ElMansoura, P.O.Box: 35516, Eldakahlia, Egypt\u003c/li\u003e\n\u003c/ol\u003e\n\u003cp\u003eMohamed Elgamal \u0026amp; Abdallah Mohammed Ibrahim,\u0026nbsp;\u003c/p\u003e\n\u003col start=\"2\" type=\"1\"\u003e\n \u003cli\u003eDepartment of Removable prosthodontics, Faculty of Dentistry, Horus University, Damietta, Egypt\u003c/li\u003e\n\u003c/ol\u003e\n\u003cp\u003eMohamed Elgamal.\u003c/p\u003e\n\u003col start=\"3\" type=\"1\"\u003e\n \u003cli\u003eDepartment of prosthodontics, Faculty of Dentistry, Kafrelsheikh University, Kafrelsheikh, Egypt\u003c/li\u003e\n\u003c/ol\u003e\n\u003cp\u003eBasem Tarek Fadl, Nourhan ahmed Ragheb.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eContributions\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eElgamal.M., as the first and corresponding author, conceived the idea, prepared the manuscript and supervised all the procedures. Ibrahim.A.M. designed the study, collected the clinical data and performed the statistical analysis. Fadl B.T. performed all clinical procedures with participants and supervised lab work procedures. Ragheb.N.A. selected participants, drafted the manuscript and interpreted the data. All authors critically discussed the results, revised the manuscript, and approved the final version.\u003c/p\u003e\n\u003cp\u003eCorresponding author\u003c/p\u003e\n\u003cp\u003eCorrespondence to\u0026nbsp;Mohamed Elgamal\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eEthics declarations\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eEthics approval and consent to participate.\u003c/p\u003e\n\u003cp\u003eThe patients were fully informed about the purpose and procedures of this study and provided written informed consent. The study was approved by the local ethical committee of the Faculty of Dentistry, Kafrelsheikh University (KFSIRB200-130)\u0026nbsp;and retrospectively registered at ClinicalTrials.gov (ClinicalTrials.gov Identifier:\u0026nbsp;NCT06412159) (03/05/2024).\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eConsent for publication\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eNot applicable.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompeting interests\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThe authors declare no competing interests.\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\n\u003cli\u003eAli Z, Baker SR, Shahrbaf S,Martin N, Vettore MV. Oral health-related quality of life after prosthodontic treatment for patients with partial edentulism: a systematic review and meta-analysis. J Prosthet Dent.2019;121:59\u0026ndash;68.\u003c/li\u003e\n\u003cli\u003eHwang D, Wang HL. Medical contraindications to implant therapy: part I: absolute contraindications. Implant Dent. 2006;15(4):353-360.\u003c/li\u003e\n\u003cli\u003eHwang D, Wang HL. Medical contraindications to implant therapy: Part II: Relative contraindications. Implant Dent. 2007;16(1):13-23.\u003c/li\u003e\n\u003c/ol\u003e\n\u003col start=\"4\"\u003e\n\u003cli\u003eViswambaran M, Sundaram RK. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures. Contemp Clin Dent 2015;4:471-6.\u003c/li\u003e\n\u003cli\u003eLang LA, Tulunoglu I. A critically appraised topic review of computer aided design/computer-aided machining of removable partial denture frameworks. Dent Clin North Am. 2014;58:247\u0026ndash;55\u003c/li\u003e\n\u003cli\u003eBarraclough O, Gray D, Ali Z, Nattress B. Modern partial dentures\u0026mdash;part 1: novel manufacturing techniques. Br Dent J. 2021;230:651\u0026ndash;57.\u003c/li\u003e\n\u003cli\u003eAlmufleh B, Arellanob A, Tamimi F. Patient-reported outcomes and framework fit accuracy of removable partial dentures fabricated using digital techniques: A systematic review and meta-analysis.\u0026nbsp;J Prosthodont. 2024;33(7):626-636.\u003c/li\u003e\n\u003cli\u003eAzari A, Nikzad S. The evolution of rapid prototyping in dentistry: a review. Rapid Prototyping Journal 2009;15:216-25.\u003c/li\u003e\n\u003cli\u003eHazeveld A, Huddleston Slater JJ, Ren Y. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques.\u0026nbsp;\u003cem\u003eAm J Orthod Dentofacial Orthop\u003c/em\u003e. 2014;145(1):108-115.\u003c/li\u003e\n\u003cli\u003eDawood A, Marti BM, Sauret-Jackson V, Darwood A. 3D printing in dentistry. Br Dent J 2015;219:521-9.\u003c/li\u003e\n\u003cli\u003eYe H, Ning J, Li M, Niu L, Yang J, Sun Y, et al. Preliminary clinical application of removable partial denture frameworks fabricated using computer-aided design and rapid prototyping techniques. Int J Prosthodont 2017;30:348-53.\u003c/li\u003e\n\u003cli\u003eZhou Y, Li N, Yan J, Zeng Q. Comparative analysis of the microstructures and mechanical properties of Co-Cr dental alloys fabricated by different methods. J Prosthet Dent 2018;120:617-23.\u003c/li\u003e\n\u003cli\u003eSalim S, Salleh NM, Abidin ZZ, Yunus N, Rahmat R, Ibrahim N. Physicomechanical properties of cobalt-chromium removable partial denture palatal major connectors fabricated by selective laser melting. \u003cem\u003eJ Prosthet Dent\u003c/em\u003e. 2022;128:530.e1\u0026ndash;530.e7.\u003c/li\u003e\n\u003cli\u003eRenne W, Ludlow M, Fryml J, Schurch Z, Mennito A, Kessler R, et al. Evaluation of the accuracy of 7 digital scanners: an in vitro analysis based on 3-dimensional comparisons. J Prosthet Dent 2017;118:36-42.\u003c/li\u003e\n\u003cli\u003eSim JY, Jang Y, Kim WC, Kim HY, Lee DH, Kim JH. Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows.\u0026nbsp;\u003cem\u003eJ Prosthodont Res\u003c/em\u003e. 2019;63(1):25-30.\u003c/li\u003e\n\u003cli\u003eHayama H, Fueki K, Wadachi J, Wakabayashi N. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible. J Prosthodont Res 2018;62:347-52.\u003c/li\u003e\n\u003cli\u003eKattadiyil MT, Mursic Z, AlRumaih H, Goodacre CJ. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication.\u0026nbsp;\u003cem\u003eJ Prosthet Dent\u003c/em\u003e. 2014;112(3):444-448.\u003c/li\u003e\n\u003cli\u003eKrahenbuhl JT, Cho SH, Irelan J, Bansal NK. Accuracy and precision of occlusal contacts of stereolithographic casts mounted by digital interocclusal registrations.\u0026nbsp;\u003cem\u003eJ Prosthet Dent\u003c/em\u003e. 2016;116(2):231-236.\u003c/li\u003e\n\u003cli\u003eLytle RB. Soft tissue displacement beneath removable partial and complete dentures. J Prosthet Dent 1962;12:34-43.\u003c/li\u003e\n\u003cli\u003eM\u0026uuml;ller P, Ender A, Joda T, Katsoulis J. Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner. Quintessence Int 2016;47:343-9.\u003c/li\u003e\n\u003cli\u003eFrank, R.P.; Brudvik, J.S.; Leroux, B.; Milgrom, P.; Hawkins, N. Relationship between the standards of removable partial denture construction, clinical acceptability, and patient satisfaction. J. Prosthet. Dent. 2000; 83: 521\u0026ndash;527.\u003c/li\u003e\n\u003cli\u003eRokhshad R, Tehrani AM, Nahidi R, Zarbakhsh A. Fit of removable partial denture frameworks fabricated from 3D printed patterns versus the conventional method: An in\u0026nbsp;vitro comparison.\u0026nbsp;J Prosthet Dent. 2024;131(6):1144-1149.\u003c/li\u003e\n\u003cli\u003eTasaka A, Shimizu T, Kato Y, et al. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering.\u0026nbsp;\u003cem\u003eJ Prosthodont Res\u003c/em\u003e. 2020;64(2):224-230.\u003c/li\u003e\n\u003cli\u003eWu J, Cheng Y, Gao B, Yu H. A novel digital altered cast impression technique for fabricating a removable partial denture with a distal extension.\u0026nbsp;\u003cem\u003eJ Am Dent Assoc\u003c/em\u003e. 2020;151(4):297-302.\u003c/li\u003e\n\u003cli\u003eGan N, Ruan Y, Sun J, Xiong Y, Jiao T. Comparison of Adaptation between the Major Connectors Fabricated from Intraoral Digital Impressions and Extraoral Digital Impressions.\u0026nbsp;\u003cem\u003eSci Rep\u003c/em\u003e. 2018;8(1):529.\u003c/li\u003e\n\u003cli\u003eChang IC, Hung CC, Du JK, Liu CT, Lai PL, Lan TH. Accuracy of intraoral scanning methods for maxillary Kennedy class I arch.\u0026nbsp;\u003cem\u003eJ Dent Sci\u003c/em\u003e. 2023;18(2):747-753.\u003c/li\u003e\n\u003cli\u003eRotar RN, Faur AB, Pop D, Jivanescu A. Scanning Distance Influence on the Intraoral Scanning Accuracy-An In Vitro Study.\u0026nbsp;Materials (Basel). 2022;15(9):3061.\u003c/li\u003e\n\u003cli\u003eConcei\u0026ccedil;\u0026atilde;o P, Portugal J, Franco M, Alves NM, Marques D, Neves CB. Comparison between digital superimposition and microcomputed tomography methods of fit assessment of removable partial denture frameworks.\u0026nbsp;J Prosthet Dent. 2024;131(3):479-486.\u003c/li\u003e\n\u003c/ol\u003e\n\u003col start=\"29\"\u003e\n\u003cli\u003eStern MA, Brudvik JS, Frank RP: Clinical evaluation of removable partial denture rest seat adaptation. J Prosthet Dent 1985;53:658-662.\u003c/li\u003e\n\u003cli\u003eEggbeer D, Bibb R, Williams R: The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks. Proc Inst Mech Eng 2005;219:195- 202.\u003c/li\u003e\n\u003cli\u003eSoltanzadeh P, Suprono MS, Kattadiyil MT, Goodacre C, Gregorius W. An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks.\u0026nbsp;J Prosthodont. 2019;28(5):547-555.\u003c/li\u003e\n\u003c/ol\u003e\n\u003col start=\"32\"\u003e\n\u003cli\u003eSuzuki Y, Harada N, Watanabe KI, Maruo R, Shimpo H, Ohkubo C. Clinical application of an intraoral scanner and CAD/CAM system for a Kennedy class I partially edentulous patient.\u0026nbsp;\u003cem\u003eJ Oral Sci\u003c/em\u003e. 2022;64(1):109-111.\u003c/li\u003e\n\u003cli\u003eSchimmel M, Akino N, Srinivasan M, Wittneben JG, Yilmaz B, Abou-Ayash S. Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis.\u0026nbsp;\u003cem\u003eClin Oral Investig\u003c/em\u003e. 2021;25(4):1839-1847.\u003c/li\u003e\n\u003cli\u003eWang X, Zhang F, Ma D, et al. Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An\u0026nbsp;\u003cem\u003ein vitro\u003c/em\u003ecomparison.\u0026nbsp;\u003cem\u003eHeliyon\u003c/em\u003e. 2024;10(10):e31063.\u003c/li\u003e\n\u003cli\u003eLee JH, Yun JH, Han JS, Yeo IL, Yoon HI. Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study.\u0026nbsp;J Clin Med. 2019;8(8):1187.\u003c/li\u003e\n\u003cli\u003eTregerman I, Renne W, Kelly A, Wilson D. Evaluation of removable partial denture frameworks fabricated using 3 different techniques. J Prosthet Dent. 2019;122(4):390-395.\u003c/li\u003e\n\u003cli\u003eBajunaid SO, Altwaim B, Alhassan M, Alammari R. The Fit Accuracy of Removable Partial Denture Metal Frameworks Using Conventional and 3D Printed Techniques: An \u003cem\u003eIn Vitro \u003c/em\u003eStudy. \u003cem\u003eJ Contemp Dent Pract. \u003c/em\u003e2019;20(4):476-481.\u003c/li\u003e\n\u003cli\u003eAhmed N, Abbasi MS, Haider S, et al. Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review.\u0026nbsp;\u003cem\u003eBiomed Res Int\u003c/em\u003e. 2021;2021:3194433.\u003c/li\u003e\n\u003cli\u003eKorkes A, Jomaa J, Kavouris A, et al. Seating accuracy of removable partial denture frameworks fabricated by different digital workflows in comparison to conventional workflow.\u0026nbsp;J Prosthodont. Published online August 8, 2024.\u003c/li\u003e\n\u003cli\u003eConcei\u0026ccedil;\u0026atilde;o P, Portugal J, Neves CB. Evaluation of Removable Partial Denture Metal Frameworks Produced by Digital Methods\u0026mdash;A Systematic Review.\u0026nbsp;Applied Sciences. 2023; 13(19):10824.\u003c/li\u003e\n\u003cli\u003eAlabdullah SA, Hannam AG, Wyatt CC, McCullagh APG, Aleksejuniene J, Mostafa NZ. Comparison of digital and conventional methods of fit evaluation of partial removable dental prosthesis frameworks fabricated by selective laser melting.\u0026nbsp;\u003cem\u003eJ Prosthet Dent\u003c/em\u003e. 2022;127(3):478.e1-478.e10.\u003c/li\u003e\n\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"[email protected]","identity":"bmc-oral-health","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"ohea","sideBox":"Learn more about [BMC Oral Health](http://bmcoralhealth.biomedcentral.com/)","snPcode":"","submissionUrl":"https://www.editorialmanager.com/ohea/default.aspx","title":"BMC Oral Health","twitterHandle":"BMC_series","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"em","reportingPortfolio":"BMC Series","inReviewEnabled":true,"inReviewRevisionsEnabled":true},"keywords":"Selective laser melting, Removable partial denture accuracy, fully-digital workflow, combined analog-digital workflow","lastPublishedDoi":"10.21203/rs.3.rs-5073463/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-5073463/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003e\u003cstrong\u003eBackground: \u003c/strong\u003eRapid advancements in computer-aided design and computer-aided manufacturing (CAD-CAM) have opened new pathways in the fabrication of removable partial dentures (RPDs). Digital impression serves as the first step of (CAD-CAM) technique, which includes two methods for data acquisition: direct intraoral scanning or indirect extraoral scanning. RPD frameworks may be considered the definitive test of accuracy for a digital workflow. This cross-over clinical study aimed to evaluate the overall accuracy of various parts for mandibular metallic RPD frameworks made by selective laser melting (SLM) using fully-digital versus combined analog-digital workflows.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eMethods: \u003c/strong\u003eThis study was carried out on 24 participants with mandibular Kennedy class I arches. Each participant received two RPDs frameworks, one fabricated using a combined analog-digital workflow (Group I) and the other using a fully- digital workflow (Group II). In Group I, the analog steps involved taking physical impressions and creating stone casts followed by scanning the casts with a laboratory scanner to create virtual casts. In Group II, a definitive scan STL file was created using an intraoral digital scanner. Both groups used 3Shape software for digital design of the RPD framework, ensuring consistency by using the same design, and subsequent fabrication using selective laser melting (SLM). To evaluate the accuracy, STL data analysis was performed through intra-oral digital superimposition evaluation, a color map was assessed and overall accuracy and the misfit (distance between each framework component and the reference intra-oral scan STL file) were measured at rest, proximal plate, lingual plate and I-bar retentive clasp terminal areas. The Paired t-test was utilized for statistical analysis of the data.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eResults: \u003c/strong\u003eIn Group I: combined analog-digital workflow color map assessment revealed more gaps particularly in the lingual plate and proximal plate areas, whereas Group II: fully-digital workflow\u003cstrong\u003e \u003c/strong\u003eshowed better accuracy. Regarding the overall accuracy in the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal, Group II \u003cstrong\u003e\u0026nbsp;\u003c/strong\u003ewas significantly superior to Group I \u003cstrong\u003e\u0026nbsp;\u003c/strong\u003e(P= 0.0125, 0.0019, \u0026lt;0.001, \u0026lt;0.001, and 0.0119, respectively).\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eConclusions: \u003c/strong\u003eWithin the limitations of this study, both workflows resulted in frameworks with clinically acceptable accuracy. However, SLM RPD frameworks fabricated using the fully-digital workflow showed superior accuracy in key areas such as the rest, proximal plate, lingual plate, and I-bar clasp retentive terminal areas, when compared to the combined analog-digital workflow.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eTrial registration: \u003c/strong\u003eRetrospectively registered (NCT06412159) 03/05/2024.\u003c/p\u003e","manuscriptTitle":"Accuracy assessment of removable partial denture frameworks fabricated by selective laser melting using two different workflows. A cross-over Clinical Study.","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2025-05-06 06:54:06","doi":"10.21203/rs.3.rs-5073463/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"decision","content":"Revision requested","date":"2025-05-15T04:42:13+00:00","index":"","fulltext":""},{"type":"editorAssigned","content":"","date":"2025-05-15T04:39:10+00:00","index":"","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2025-05-13T13:18:18+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"80630789561551660678474052177626995105","date":"2025-05-08T06:07:06+00:00","index":"hide","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2025-05-04T18:50:31+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"236060195052588760343588556704378845016","date":"2025-05-04T18:48:38+00:00","index":"hide","fulltext":""},{"type":"reviewersInvited","content":"","date":"2025-05-02T18:17:39+00:00","index":"","fulltext":""},{"type":"checksComplete","content":"","date":"2025-05-02T11:35:48+00:00","index":"","fulltext":""},{"type":"submitted","content":"BMC Oral Health","date":"2025-04-24T06:59:04+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"[email protected]","identity":"bmc-oral-health","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"ohea","sideBox":"Learn more about [BMC Oral Health](http://bmcoralhealth.biomedcentral.com/)","snPcode":"","submissionUrl":"https://www.editorialmanager.com/ohea/default.aspx","title":"BMC Oral Health","twitterHandle":"BMC_series","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"em","reportingPortfolio":"BMC Series","inReviewEnabled":true,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"7fca4450-7467-4672-bfb2-6876559045a0","owner":[],"postedDate":"May 6th, 2025","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[],"tags":[],"updatedAt":"2025-06-02T16:06:22+00:00","versionOfRecord":{"articleIdentity":"rs-5073463","link":"https://doi.org/10.1186/s12903-025-06214-9","journal":{"identity":"bmc-oral-health","isVorOnly":false,"title":"BMC Oral Health"},"publishedOn":"2025-05-28 15:57:08","publishedOnDateReadable":"May 28th, 2025"},"versionCreatedAt":"2025-05-06 06:54:06","video":"","vorDoi":"10.1186/s12903-025-06214-9","vorDoiUrl":"https://doi.org/10.1186/s12903-025-06214-9","workflowStages":[]},"version":"v1","identity":"rs-5073463","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-5073463","identity":"rs-5073463","version":["v1"]},"buildId":"8U1c8b4HqxoKbykW_rLl7","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-05-28T02:00:01.590549+00:00
License: CC-BY-4.0