Physical activity traits from wrist sensors correlate with clinical status in pediatric pulmonary hypertension

preprint OA: closed
📄 Open PDF Full text JSON View at publisher

Abstract

Physical activity (PA) estimated by a wearable sensor may reflect clinical status in pediatric pulmonary hypertension (PH). Prior studies used research-grade hip-anchored sensors or commercial wrist sensors with proprietary scoring algorithms. Wrist sensors offer better acceptability in children, however, their ability to detect associations between PA and clinical characteristics is unknown. Youth 8-18 years with PH [Groups 1-4, functional class (FC) I-II] and healthy controls wore a GENEActiv accelerometer on the non-dominant wrist for 14 days. Raw acceleration data were processed using the open-source GGIR R-package. Participants completed a 6-minute walk distance (6MWD) and quality-of-life questionnaire. Muscle mass and strength were assessed by densitometry and handgrip dynamometry. Most recent cardiac testing was extracted from the medical record. Groups were compared by Fisher’s exact test, unpaired t-test, or Wilcoxon rank sum test. Multivariate regression models assessed for associations between PA and clinical metrics. Thirty PH participants (median 13.9 years, 57% female, 57% Group 1, 50% FC I) and 29 controls were included. Total PA was similar. PH participants demonstrated fewer and shorter bouts of moderate-to-vigorous PA ≥10 minutes and more time spent at lower PA intensities. In PH participants, muscle mass was positively associated with PA but 6MWD was negatively associated with PA. PA was not associated with quality-of-life. Within the PH group, worse PA traits were associated with lower FC and worse clinical testing. Wrist sensors reveal deficits in PA traits including reduced moderate-to-vigorous activity bouts and lower intensity gradients in pediatric PH.
Full text 63,164 characters · extracted from preprint-html · click to expand
Physical activity traits from wrist sensors correlate with clinical status in pediatric pulmonary hypertension | medRxiv /* */ /* */ <!-- <!-- /*! * yepnope1.5.4 * (c) WTFPL, GPLv2 */ (function(a,b,c){function d(a){return"[object Function]"==o.call(a)}function e(a){return"string"==typeof a}function f(){}function g(a){return!a||"loaded"==a||"complete"==a||"uninitialized"==a}function h(){var a=p.shift();q=1,a?a.t?m(function(){("c"==a.t?B.injectCss:B.injectJs)(a.s,0,a.a,a.x,a.e,1)},0):(a(),h()):q=0}function i(a,c,d,e,f,i,j){function k(b){if(!o&&g(l.readyState)&&(u.r=o=1,!q&&h(),l.onload=l.onreadystatechange=null,b)){"img"!=a&&m(function(){t.removeChild(l)},50);for(var d in y[c])y[c].hasOwnProperty(d)&&y[c][d].onload()}}var j=j||B.errorTimeout,l=b.createElement(a),o=0,r=0,u={t:d,s:c,e:f,a:i,x:j};1===y[c]&&(r=1,y[c]=[]),"object"==a?l.data=c:(l.src=c,l.type=a),l.width=l.height="0",l.onerror=l.onload=l.onreadystatechange=function(){k.call(this,r)},p.splice(e,0,u),"img"!=a&&(r||2===y[c]?(t.insertBefore(l,s?null:n),m(k,j)):y[c].push(l))}function j(a,b,c,d,f){return q=0,b=b||"j",e(a)?i("c"==b?v:u,a,b,this.i++,c,d,f):(p.splice(this.i++,0,a),1==p.length&&h()),this}function k(){var a=B;return a.loader={load:j,i:0},a}var l=b.documentElement,m=a.setTimeout,n=b.getElementsByTagName("script")[0],o={}.toString,p=[],q=0,r="MozAppearance"in l.style,s=r&&!!b.createRange().compareNode,t=s?l:n.parentNode,l=a.opera&&"[object Opera]"==o.call(a.opera),l=!!b.attachEvent&&!l,u=r?"object":l?"script":"img",v=l?"script":u,w=Array.isArray||function(a){return"[object Array]"==o.call(a)},x=[],y={},z={timeout:function(a,b){return b.length&&(a.timeout=b[0]),a}},A,B;B=function(a){function b(a){var a=a.split("!"),b=x.length,c=a.pop(),d=a.length,c={url:c,origUrl:c,prefixes:a},e,f,g;for(f=0;f<d;f++)g=a[f].split("="),(e=z[g.shift()])&&(c=e(c,g));for(f=0;f<b;f++)c=x[f](c);return c}function g(a,e,f,g,h){var i=b(a),j=i.autoCallback;i.url.split(".").pop().split("?").shift(),i.bypass||(e&&(e=d(e)?e:e[a]||e[g]||e[a.split("/").pop().split("?")[0]]),i.instead?i.instead(a,e,f,g,h):(y[i.url]?i.noexec=!0:y[i.url]=1,f.load(i.url,i.forceCSS||!i.forceJS&&"css"==i.url.split(".").pop().split("?").shift()?"c":c,i.noexec,i.attrs,i.timeout),(d(e)||d(j))&&f.load(function(){k(),e&&e(i.origUrl,h,g),j&&j(i.origUrl,h,g),y[i.url]=2})))}function h(a,b){function c(a,c){if(a){if(e(a))c||(j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}),g(a,j,b,0,h);else if(Object(a)===a)for(n in m=function(){var b=0,c;for(c in a)a.hasOwnProperty(c)&&b++;return b}(),a)a.hasOwnProperty(n)&&(!c&&!--m&&(d(j)?j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}:j[n]=function(a){return function(){var b=[].slice.call(arguments);a&&a.apply(this,b),l()}}(k[n])),g(a[n],j,b,n,h))}else!c&&l()}var h=!!a.test,i=a.load||a.both,j=a.callback||f,k=j,l=a.complete||f,m,n;c(h?a.yep:a.nope,!!i),i&&c(i)}var i,j,l=this.yepnope.loader;if(e(a))g(a,0,l,0);else if(w(a))for(i=0;i (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0];var j=d.createElement(s);var dl=l!='dataLayer'?'&l='+l:'';j.src='//www.googletagmanager.com/gtm.js?id='+i+dl;j.type='text/javascript';j.async=true;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-P4HH5NV'); Skip to main content Home About Submit ALERTS / RSS Search for this keyword Advanced Search Physical activity traits from wrist sensors correlate with clinical status in pediatric pulmonary hypertension Catherine M. Avitabile , Pin-Wei Chen , Walter Faig , View ORCID Profile Babette Zemel , Jonathan A. Mitchell doi: https://doi.org/10.1101/2025.10.26.25338733 Catherine M. Avitabile 1 Department of Pediatrics, University of Pennsylvania, Perelman School of Medicine; 2 Division of Cardiology, Children’s Hospital of Philadelphia; MD Find this author on Google Scholar Find this author on PubMed Search for this author on this site For correspondence: avitabilec{at}chop.edu Pin-Wei Chen 3 Data Science and Biostatistics Unit, Department of Biomedical and Health Informatics, Children’s Hospital of Philadelphia; PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site Walter Faig 4 Biostatistics and Data Management Core, Children’s Hospital of Philadelphia; PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site Babette Zemel 1 Department of Pediatrics, University of Pennsylvania, Perelman School of Medicine; 5 Division of Gastroenterology, Hepatology, and Nutrition, Children’s Hospital of Philadelphia PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Babette Zemel Jonathan A. Mitchell 1 Department of Pediatrics, University of Pennsylvania, Perelman School of Medicine; 5 Division of Gastroenterology, Hepatology, and Nutrition, Children’s Hospital of Philadelphia PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site Abstract Full Text Info/History Metrics Data/Code Preview PDF Abstract Physical activity (PA) estimated by a wearable sensor may reflect clinical status in pediatric pulmonary hypertension (PH). Prior studies used research-grade hip-anchored sensors or commercial wrist sensors with proprietary scoring algorithms. Wrist sensors offer better acceptability in children, however, their ability to detect associations between PA and clinical characteristics is unknown. Youth 8-18 years with PH [Groups 1-4, functional class (FC) I-II] and healthy controls wore a GENEActiv accelerometer on the non-dominant wrist for 14 days. Raw acceleration data were processed using the open-source GGIR R-package. Participants completed a 6-minute walk distance (6MWD) and quality-of-life questionnaire. Muscle mass and strength were assessed by densitometry and handgrip dynamometry. Most recent cardiac testing was extracted from the medical record. Groups were compared by Fisher’s exact test, unpaired t-test, or Wilcoxon rank sum test. Multivariate regression models assessed for associations between PA and clinical metrics. Thirty PH participants (median 13.9 years, 57% female, 57% Group 1, 50% FC I) and 29 controls were included. Total PA was similar. PH participants demonstrated fewer and shorter bouts of moderate-to-vigorous PA ≥10 minutes and more time spent at lower PA intensities. In PH participants, muscle mass was positively associated with PA but 6MWD was negatively associated with PA. PA was not associated with quality-of-life. Within the PH group, worse PA traits were associated with lower FC and worse clinical testing. Wrist sensors reveal deficits in PA traits including reduced moderate-to-vigorous activity bouts and lower intensity gradients in pediatric PH. Introduction Pediatric pulmonary hypertension (PH) is a rare but lethal disease with a reported prevalence of 30 per million children and 75% 5-year survival ( 1 – 5 ). Increased right ventricular afterload leads to right heart dysfunction, heart failure, and high risk of mortality without treatment. Only two pulmonary vasodilator medications are approved by the United States Food and Drug Administration for treatment of pediatric PH. One of the limitations to clinical trials in pediatric PH is the lack of non-invasive, easily accessible endpoints reflective of functional status in children of all ages. As dyspnea and exercise intolerance are common complaints in both children and adults with PH, the 6-minute walk distance (6MWD) is the most common functional endpoint in adult PH trials. However, the test is technically challenging or even impossible in many children due to age or developmental status ( 6 ) and typically requires travel to a dedicated pediatric PH center. Wearable devices with an accelerometer sensor enable naturalistic estimation of physical activity (PA) in a patient’s daily life and may be more reflective of functional status than periodic, brief exercise testing. Multiple adult PH studies have demonstrated associations between lower PA measures and worse disease severity including worse quality of life, higher fatigue scores, lower 6MWD, and worse performance on cardiopulmonary exercise testing ( 7 – 13 ). In pediatric PH, PA measured by a hip-worn sensor correlated positively with 6MWD and negatively with functional class (reflecting worse symptoms) ( 14 ). However, children seem to be more compliant with wrist-worn sensors ( 15 – 17 ) which has led to interest in using wrist sensors in clinical trials with repeat activity assessments. Since commercial wrist sensors are subject to proprietary data and processing algorithms, capturing raw sensor data with a research-grade device and processing the data with open-source software is a more rigorous and reproducible approach for both observational studies and clinical trials. Standardized data processing methods are necessary to advance the use of accelerometry in PH research and clinical care. To date, no studies have estimated PA using open-source scoring software to process raw sensor data captured by a wrist-worn wearable in children with PH. Additionally, the associations between PA measured by a research-grade wrist-worn sensor and functional health status in youth with PH are unknown. Therefore, the goals of the current study were to 1) compare PA estimates between children with PH and healthy controls and 2) to explore the associations between PA and markers of functional health status (6MWD, skeletal muscle mass and strength, quality-of-life questionnaire score, cardiac testing) in children with PH using a research-grade wrist sensor and processing the raw sensor data with open-source software to generate PA traits. Methods Study population Ambulatory children and adolescents ages 8-18 years with World Symposium of PH Groups 1-4 and World Health Organization functional class (FC) I-II were enrolled in a cross-sectional study and compared to healthy, typically developing control participants in the same age range. For each PH participant, one control participant was enrolled matched on age in years, race, sex, and body mass index category (85 th percentile=overweight/obese). PH participants were excluded for single ventricle physiology, moderate-severe renal or hepatic impairment, pregnancy, or significant developmental delay/inability to comply with instructions to complete the procedures. Control participants were excluded for PH, congenital or acquired heart disease, moderate-severe asthma or other pulmonary disease, musculoskeletal condition, pregnancy, moderate to severe renal or hepatic impairment, significant developmental delay/inability to comply with instructions to complete the procedures, or any chronic condition requiring routine care by a specialist. Informed consent was obtained from the parent/legal guardian of participants <18 years and of participants 18 years of age; informed assent was obtained from participants <18 years. This study was approved by the Children’s Hospital of Philadelphia Institutional Review Board (IRB #20-017827, and all data were collected between 2021 and 2024. Study procedures PH history PH classification, functional class, medications, brain type natriuretic peptide level, and data from most recent echocardiogram and cardiac catheterization were abstracted from the medical record. Echocardiographic data included tricuspid annular plane systolic excursion Z-score, right ventricular fractional area change, right ventricular longitudinal and free wall strain, left ventricular eccentricity index, and right ventricular/left ventricular ratio as per our comprehensive PH and right ventricular function echocardiography protocol. Right ventricular fractional area change was calculated as the end-diastolic area minus the end-systolic area divided by the end-diastolic area ( 18 ). Right ventricular longitudinal and free wall strain were measured from apical 4-chamber view using the vendor package with adjustment of the auto-tracings. By convention, strain is reported as a negative number, with greater absolute value indicating better systolic function ( 19 ). Absolute value of the strain measures was used in this study. Abnormal ventricular septal position was measured by end-systolic left ventricular eccentricity index, the ratio of the left ventricular dimension parallel to the ventricular septum to the left ventricular dimension perpendicular to the ventricular septum in parasternal short axis view at the level of the papillary muscles ( 18 ). In one report, end-systolic left ventricular eccentricity index > 1.16 best identified the presence of PH ( 20 ). Two-dimensional systolic right ventricular/left ventricular ratio was also measured in the parasternal short axis view at the level of the papillary muscles ( 18 ). Right ventricular/left ventricular ratio increases with worsening right ventricular dilation, and a value > 1 is associated with worse clinical events in PH ( 21 ). Anthropometry Weight was measured to the nearest 0.1 kg on a digital scale (Scaletronix, Skaneateles, NY). Height and sitting height were measured to the nearest 0.1 cm with a wall-mounted stadiometer (Holtain, Crymych, UK) and a sitting platform without shoes or hair adornments. Leg length was calculated as height minus sitting height. Growth variables were converted to Z-scores (standard deviation scores) as per prior studies from our team ( 22 – 26 ). Sex-specific Z-scores for height, weight, and body mass index relative to age were calculated using the 2000 Centers for Disease Control and Prevention growth charts ( 27 ). Densitometry measures of lean mass Body composition was measured using a Hologic Horizon fan-beam dual energy X-ray densitometer (DXA; Bedford, MA). The machine was set to array mode using Apex software. Regional and whole-body measurement of bone mineral content and density, fat mass, fat free mass, lean body mass, percent body fat, and fat distribution was obtained. Published body composition reference data were used to calculate sex- and race-specific leg lean mass Z-scores (LLMZ) relative to age ( 28 , 29 ). As PH physiology is associated with impaired linear growth ( 30 ), LLMZ was further adjusted for leg length Z-score ( 31 ). Upper extremity muscle strength Bilateral forearm strength was measured with a handgrip dynamometer (Takei, Tokyo, Japan) ( 32 ). The participant stood upright with the shoulder adducted holding the dynamometer, not touching the trunk. The handle was adjusted to the hand size of the participant, and no extra body movement was allowed during testing. For each hand, 3 maximal effort trials lasting 4-5 seconds interspersed with 60-second rests were carried out. The highest value (kg) from each hand was retained for analysis. Sex-specific dominant and non-dominant handgrip Z-scores were generated using data from the 2011-2012 and 2013-2014 releases of the US National Health and Nutrition Examination Survey (NHANES) ( 29 , 33 ). Heath-related quality of life Participants and parents or legal guardians completed the PedsQL (version 3.0, Cardiac Module: Pulmonary Hypertension for PH participants and standard PedsQL for control participants), a brief, practical, reliable, vaildated instrument to assess health related quality of life ( 34 ), the perception of the impact of an illness, medical therapy, or condition on a person’s ability to participate in and find satisfaction in life’s shared experiences. It assesses physical, emotional, social, and school functioning. A total summary score and physical and psychosocial health subscores are generated. Scores of 0-100 are possible with higher scores representing better quality of life. 6-minute walk distance (6MWD): Control participants performed a 6MWD at their study visit. For PH participants, the most recent standard of care 6MWD was included. As much as possible, the study visit occurred the same day as a routine clinical visit in PH participants, and the standard of care 6MWD was performed the same day as other research testing. All tests were performed according to American Thoracic Society guidelines ( 35 ). Patients walked at their own pace to cover as much distance as possible in 6 minutes along a 45-m course marked at 1-m intervals in a level hospital corridor. Heart rate and oxygen saturation were measured continuously by non-invasive pulse oximetry (Nelcor Oximax N-65, Minneapolis, MN). Estimation of physical activity by wearable sensor Participants wore a GENEActiv device on their non-dominant wrist for 14 days after the study visit. Raw sensor data were collected at a sampling rate of 30 Hz. The GGIR R-package version 3.0-0 ( 36 ) was used to process the multiple days of raw gravitational acceleration data (g/m 2 ) to estimate PA parameters. First, all raw data files were auto calibrated, with the imputation processes enabled ( 37 ), and processed using the Euclidian norm minus one (ENMO) approach ( 38 ). The auto-calibration algorithm and ENMO are preprocessing steps typical in most accelerometer data. Auto-calibration estimates potential sensor calibration errors and recalibrates the activity data ( 37 ). The ENMO algorithm separates the gravitational components and the movement components, turning raw data into an easier-to-process activity intensity ( 38 ). Second, the GGIR default non-wear detection algorithm was applied ( 39 ). GGIR non-wear detection uses standard deviation and range of low acceleration values to estimate whether one is wearing the watch. Third, the Cole-Kripke sleep scoring algorithm was used with the “Heuristic algorithm looking at Distribution of Change in Z-Angle” (HDCZA) to detect sleep periods ( 40 ). HDCZA uses the estimated z-axis angle to make basic assumptions about sleep start and stop ( 40 ). This is done when there is no sleep diary to guide the sleep algorithm to accurately predict sleep onset and offset. The Cole-Kripke algorithm is one of the classic sleep algorithms to determine sleep-wake cycles. Lastly, PA levels were quantified during the remaining wake periods for each day. Since there are no PA intensity cut points validated for the PH population, we investigated three cut point settings including the most commonly used cut point in GGIR (GGIR default) and two that partially matched with the study age group and device/wear location: Schaefer 2014 (children ages 6-11 years, GENEActiv wrist) ( 41 ) and Hildebrand 2014 (adults and children ages 7-11 years, ActiGraph hip/GENEActiv wrist) ( 42 ). When examining the face validity of the moderate-to-vigorous PA (MVPA) outputs, daily estimates were either much too low (median 0 minutes with no range with Hildebrand) or too high (median 25-30 minutes with Schaefer) based on prior work in the PH population. Therefore, even if these settings matched with the specific age range/device, the face validity did not support using them when studying pediatric PH participants and comparing them to a group of relatively healthy individuals of the same age range. Based on this, we used the most common GGIR default cut points which demonstrated better face validity. Three general filters were used to screen out days with extreme values: 1) daytime data ≤ 8 hours; 2) daytime non-wear percentage ≥25%; and 3) daytime accumulation >24 hours. These filters serve to reduce the number of errors from GGIR estimations. The default GGIR cut points were used to estimate time spent in sedentary behavior and PA intensities (minutes per day): sedentary, <30 gravitational units; light physical activity, 30-100 gravitational units; moderate physical activity, 101-400 gravitational units; and vigorous physical activity, ≥400 gravitational units. Since typical arm movements may inflate PA estimates, bouts of physical activity were also estimated. For MVPA, bouts were reported at 1-, 5-, and 10-minute intervals; for light PA and sedentary behavior, bouts were calculated at 1-, 10-, 30-minute intervals. Note, a bout was defined as a timed interval of continuous movement, of which ≥80% of the time interval is spent in sedentary behavior or at a specific PA intensity. GGIR was also used to generate the PA intensity gradient ( 43 ). The intensity gradient sorts the participant’s full spectrum of PA data into intensity-based bins and uses the log–log slope of the intensity and time accumulated at each intensity to quantify the distribution of the individual’s PA intensity. The intensity gradient is a cut point-independent metric. The slope of the intensity gradient is negative to reflect less time spent at higher intensities. A steeper, more negative, slope with a higher constant (y-intercept) indicates a steep drop in time accumulated with increasing intensity and an uneven distribution of time spent across all intensities (e.g., more time at lower intensities); a shallower slope indicates a more even distribution of time spent at all PA intensities (e.g., more time at higher intensities) ( 43 ). Statistical analyses Standard descriptive statistics [mean ± standard deviation or median (interquartile range)] were used to summarize demographics, clinical characteristics, LLMZ, handgrip Z-scores, quality of life scores, and PA. All days of PA data were analyzed and daily averages over the observation period are presented. Comparisons between PH and control participants were performed by Fisher’s exact test for categorical variables and unpaired t-test or Wilcoxon rank sum test (if not normally distributed) for continuous variables. Multivariate regression models were created to assess for associations between PA and demographic characteristics (including age, sex, and height Z-score), LLMZ, handgrip Z-score, quality of life scores in PH and control participants. Univariate regression was used to assess for associations between PA and PH disease-specific characteristics in PH participants. 6MWD was scaled by 100-meter change. Variable-by-PH status interaction terms were included to consider differential associations by PH status. Analyses were conducted in SAS with two-sided tests of hypotheses and a p - value <0.05 as the criterion for clinical significance. Results Thirty PH participants and 30 healthy control participants were enrolled. One healthy control participant was excluded from analysis due to ≤ 8 hours of daytime data on all observation days. Age, sex, race, and ethnicity compositions were similar between the PH and control participants ( Table 1 ). Height and weight Z-scores, LLMZ, handgrip Z-scores, and 6MWD were lower in PH participants compared to control participants ( Table 1 ). PedsQL total scores were comparable between PH and control participants ( Table 1 ). View this table: View inline View popup Download powerpoint Table 1. Characteristics of PH and healthy control participants 1 In PH participants, the median (interquartile range) time interval between 6MWD and start of PA assessment was 0 (0,0) days. Data expressed as count (%) or median (interquartile range). PH, pulmonary hypertension; BMI, body mass index; 6MWD, 6-minute walk distance Clinical characteristics of the PH participants are detailed in Table 2 . Most participants were World Symposium of PH Group 1 or 3. Participants were evenly split between FC I and II. Most were treated with dual enteral vasodilator therapy at the time of the study, however 23% were on triple therapy. Median BNP was low. Quantitative echocardiographic assessment reflected normal to mildly diminished right ventricular systolic function without significant right ventricular dilation on average. Summary cardiac catheterization data for the cohort were consistent with mild elevation in pulmonary artery pressure and pulmonary vascular resistance and normal cardiac index. View this table: View inline View popup Download powerpoint Table 2. PH-specific clinical characteristics PA characteristics are displayed in Table 3 . The number of valid wear days was similar between the groups. Total PA time and time by intensity level (sedentary, light PA, and MVPA) did not differ between the groups. However, there were differences in bouts of MVPA. PH participants demonstrated fewer [median 0.5 (IQR 0.13, 1.5) in PH vs. 1.6 (0.9, 3.8) in controls] and shorter [7.7 (1.3, 16.6) in PH vs. 24.8 (11.0, 44.5) in controls] bouts of MVPA ≥10 minutes. PH participants, on average, engaged in 15 minutes less MVPA when defined in bouts ≥10 minutes. PH participants also demonstrated greater number [7 ( 4 , 9 ) in PH vs. 4 ( 2 , 7 ) in controls] and higher percentage [69 ( 38 , 88) in PH vs. 33 ( 15 , 62) in controls] of days with zero bouts of MVPA ≥10 minutes achieved. View this table: View inline View popup Download powerpoint Table 3. Physical activity characteristics summarized over observation period The slope of the intensity gradient was more negative in PH participants compared to control participants ( Table 3 ). This finding reflects a steeper slope of the intensity gradient and more time spent at lower intensities. The intercept of the intensity gradient was comparable between PH and control participants. When adjusted for age, sex, and height Z-score, PH status remained associated with shorter MVPA bouts ≥10 minutes (p<0.01) and steeper slope of the intensity gradient (p<0.01) compared to control participants. PH status nearly reached statistical significance for number of MVPA bouts ≥10 minutes (p=0.05). PH status was not significant for other PA traits when adjusted for age, sex, and height Z-score. Multivariate regression models for associations between PA and participant characteristics in PH and healthy controls are displayed in Table 4 . Each model included a single PA trait. In comparing PH participants to healthy controls, the interaction analyses revealed several instances where PH status changed the impact of an exposure on the PA traits including unbouted MVPA, MVPA bouts ≥10 minutes, and slope of the intensity gradient. On average, unbouted MVPA was lower in female participants compared to male participants. However, PH status attenuated the lower MVPA in females compared to males ( Table 4 A, model #1). For example, compared to control males, average daily unbouted MVPA was 12.5 minutes less in control females, 14.5 minutes less in PH males, and 9.1 minutes less in PH females. Sex differences in MVPA were less pronounced in PH participants compared to control participants. Similarly, on average, unbouted MVPA was lower in Black participants compared to non-Black participants. Again, PH status attenuated the lower MVPA in Black participants compared to non-Black participants ( Table 4 A, model #2). Compared to non-Black control participants, average daily unbouted MVPA was 16 minutes less in Black controls, 6.9 minutes less in non-Black PH participants, and 7.1 minutes less in Black PH participants. Racial differences in MVPA were less pronounced in PH participants compared to control participants. View this table: View inline View popup Download powerpoint Table 4. General linear regression models for the associations between PA and participant characteristics in PH and healthy controls. Multivariate models with A) unbouted MVPA as dependent variable, B) slope of the intensity gradient as dependent variable, C) number of MVPA bouts ≥10 minutes as dependent variable, and D) duration of MVPA bouts ≥10 minutes as dependent variable. Each model includes a single PA trait. Similar findings were seen with the slope of the intensity gradient ( Table 4 B). On average, the slope of the intensity gradient was more negative (steeper = more time spent at lower intensities) in female participants compared to male participants and Black participants compared to non-Black participants. However, PH status attenuated these sex and race group differences and resulted in a shallower slope of the intensity gradient ( Table 4 B, model #1 and #2). In PH participants, LLMZ attenuated the negative slope of the intensity gradient ( Table 4 B, model #3) and was positively associated with longer MVPA bouts ≥ 10 minutes ( Table 4 D, model #1). However, while 6MWD was positively associated with PA overall, the association was negative in PH participants. In PH participants, 6MWD was negatively associated with the number ( Table 4 C, model #1) and duration ( Table 4 D, model #2) of MVPA bouts ≥ 10 minutes. For each 100-meter increase in 6MWD, the number of daily MVPA bouts ≥ 10 minutes decreased by 0.4 and the duration of MVPA bouts ≥ 10 minutes decreased by 0.37 minute. This negative association persisted after controlling for age, gender, and height Z-score. Univariate regression models within the PH group are displayed in Table 5 . Each model included one PA trait and one PH characteristic. Associations were identified between individual PA traits (unbouted MVPA, duration of MVPA bouts ≥10 min, and slope of the intensity gradient) and indicators of PH severity [right heart function measured by right ventricular fractional area change on echocardiogram, cardiac catheterization hemodynamics (mean pulmonary artery pressure, cardiac index, indexed pulmonary vascular resistance), and functional class (symptom severity)]. Associations were consistent with clinical severity: higher right ventricular fractional area change (better heart function) was associated with better PA traits while higher mean pulmonary artery pressure and indexed pulmonary vascular resistance (worse hemodynamics) and higher functional class (worse symptomatology) were associated with worse PA traits. PA traits discriminated by functional class (Figure). There were no associations between PA and brain type natriuretic peptide level or other echocardiographic measures right heart function within the PH group. View this table: View inline View popup Download powerpoint Table 5. General linear regression models for the associations between PA and PH characteristics. Univariable models with A) unbouted MVPA as dependent variable, B) duration of MVPA bouts ≥10 minutes and C) slope of the intensity gradient as dependent variable. Each model includes one PA trait and one PH characteristic. Discussion This is the first study to process raw acceleration data from a research-grade wrist sensor to derive estimates of PA in pediatric PH patients and demonstrate deficits in PA levels compared to healthy peers and in relation to PH disease severity. We observed that PH participants demonstrated fewer and shorter daily MVPA bouts greater than 10 minutes and steeper decline in the intensity gradient indicating an uneven distribution of time spent across all PA intensities and more time spent at lower intensities. In PH participants, LLMZ attenuated the negative slope of the intensity gradient and was positively associated with PA bouts suggesting an important role for skeletal muscle in these patients. Within the PH group, less time spent in MVPA (overall and in bouts) and steeper decline in the intensity gradient were associated with higher PH severity. These findings indicate that bouted MVPA estimates and intensity gradient estimates may have utility in pediatric PH. Unbouted MVPA estimates from wrist-worn devices are likely less reliable due to brief motion artifacts such as short arm movements which are not reflective of physical exertion. Uncovering differences in bouted PA may reflect a fundamental lack of endurance in PH and lead to new clinical trial outcomes. Despite many medication trials in adult PH, there have been very few in children ( 44 – 46 ). One major limitation to clinical trials is the lack of relevant trial endpoints reflective of hemodynamics or functional status in children in whom standard exercise testing is impractical, unreliable, or not reproducible ( 6 ). Wearable sensors facilitate observation of patients at home without travel to a sophisticated testing center. MVPA estimated by a research-grade hip-worn sensor and analyzed in the vendor’s software platform was associated with longer 6MWD and lower functional class ( 14 ). However, greater acceptability of and compliance with wrist worn devices in children ( 16 ) has generated enthusiasm for using these sensors in clinical care and clinical trials ( 47 ). In a multi-center observational study performed within the North American Pediatric Pulmonary Hypertension Network (PPHNet), it was feasible to measure PA in even the youngest pediatric PH patients using both a research-grade hip sensor and a commercial wrist-worn sensor ( 48 ). In contrast to the raw acceleration data obtained from research-grade sensors ( 49 , 50 ), commercial wrist sensors use proprietary software and non-transparent data processing algorithms to convert raw acceleration data to activity volume and intensity. Raw data are not available to the investigator, limiting data analyses. Algorithms can change or devices can be removed from the market without notice, disrupting research and clinical care. Additionally, U.S. federal legislation – the Children’s Online Privacy Protection Act – limits the upload of activity data to commercial websites or online services, such as commercial activity tracker platforms, in kids younger than 13 years. Even with parent accounts, computing expertise is needed to draw data from commercial cloud storage into a research database. Ours is the first pediatric PH study to measure PA with the research-grade GENEActiv wrist sensor, analyze the raw PA data, and demonstrate associations between wrist-derived PA and clinical parameters. The raw data can be re-analyzed as new open-source methodologies become available, increasing rigor and reproducibility. When using research-grade devices, investigators apply published “cut points” to translate activity counts to PA intensity levels [e.g. sedentary, light, MVPA] ( 51 , 52 ). In other pediatric PH studies, this has been done within the ActiGraph vendor’s software ( 14 , 48 ). Various cut points are published from distinct, small metabolic studies of healthy people within limited age ranges ( 53 – 55 ). This limits comparisons among studies with different conditions, ages, devices, or wear locations. PA data from prior studies in pediatric PH have been analyzed using hip cut points ( 14 , 56 ). Thresholds of activity counts and MVPA that correspond to changes in clinical parameters in children with PH have been published for hip worn ActiGraph sensors using hip-derived cut points ( 57 ), however, it is critical to note that the best cut-point for estimation of PA intensity from wrist-worn devices in children is unknown. It is important that hip thresholds are not applied to wrist acceleration data since wrist acceleration is greater than hip acceleration with certain activities ( 16 , 49 ). Cut points to estimate time spent in PA intensities, specific to wrist acceleration data, are available in GGIR. In our study, there were no differences in total PA, PA of various intensity levels (sedentary, light, MVPA), or unbouted PA in PH participants compared to healthy control participants. However, when bouts of MVPA greater than 10 minutes were examined, PH participants demonstrated fewer and shorter bouts. They had more days without any 10-minute bouted activity compared to healthy control children. These findings suggest that total PA intensity and volume measured by a wrist sensor may be contaminated by brief arm movements not reflective of full body PA. Measuring MVPA bouts may be more reflective of sustained exertion. Our study also highlights the potential importance of the intensity gradient, a cut point-independent metric in pediatric PH. PH participants demonstrated steeper (more negative) slope of the intensity gradient reflecting an uneven distribution of time spent across all intensities with more time at lower intensities and less time at higher intensities. The impact of PH status on duration of MVPA bouts ≥10 min and slope of the intensity gradient persisted after controlling for age, sex, and height Z-score. These findings may reveal unique limitations in endurance in pediatric PH and may be new targets for clinical trials. Both known (MVPA) and new (MVPA bouts and intensity gradient) traits associated with PH severity by echocardiogram, cardiac catheterization, and functional classification in the expected direction. Even in these “stable,” prevalent PH patients with relatively “reassuring” echocardiographic and hemodynamic assessment, PA was different than control patients and correlated with clinical severity. The findings suggest that PA estimated by a research-grade wrist sensor may have potential as a functional endpoint in pediatric PH. It is key to study these individual wrist-derived PA traits in larger studies to evaluate their suitability as outcomes in clinical trials. PH status attenuated sex- and race-group differences in wrist-derived PA metrics, indicating that PH physiology has a greater effect on PA than other demographic characteristics. However, the effect of LLMZ on some PA traits was greater in PH participants compared to healthy control participants. This finding is consistent with our prior data demonstrating LLMZ deficits (skeletal muscle deficits) in association with poor exercise performance in youth with PH ( 24 , 25 ). Interventions to augment skeletal muscle deficits may improve PA and exercise performance in children with PH, as has been demonstrated in several adult PH exercise trials ( 58 – 60 ). Interestingly, the effect of 6MWD on some PA traits was less in PH participants compared to healthy control participants. These findings should be explored in larger studies with longitudinal data to determine if there is an association between wrist-measured PA and 6MWD in children with PH. PA estimation by a wearable sensor may augment home monitoring rather than one-time evaluation in a testing environment, especially in individuals who have difficulty performing standard exercise testing. Our study has limitations. First, the sample is relatively small and originates from a single center PH program. The study included patients from World Symposium of PH Groups 1-4 which may contribute to heterogeneity of results. A larger, multi-center study may identify activity profiles specific to PH Groups (i.e. Group 1 vs. Group 3). Participants were limited to those in functional classes I and II. More profound differences in PA traits and stronger associations with clinical characteristics may be evident with a broader sample including PH patients with more advanced disease. Secondly, the study included patients 8-18 years of age. Future studies will apply these methods to wrist sensors in younger children (≤8 years) who universally cannot perform the 6MWD and other exercise testing and have the most urgent need for age-appropriate endpoints. Third, this study included prevalent PH patients, often several years from presentation and diagnosis, examined in a cross-sectional design. This study design does not allow us to predict clinical status from PA traits. However, it is notable that despite our aggressive treatment, well-managed disease, and relatively “reassuring” cardiac testing, these patients have reduced PA compared to controls and their PA parameters correlate with clinical severity. These findings should be testing in longitudinal studies including incident patients. Finally, the PA metrics in this study (other than intensity gradient) are cut point dependent. Future studies will explore device- and cut point-independent metrics including monitor independent movement summary (MIMS) units and PA percentiles derived from national representative PA data ( 61 ). In conclusion, PH participants engaged in less PA compared to healthy controls as indicated by fewer and shorter MVPA bouts ≥10 minutes and steeper slope of the intensity gradient estimated by a wrist-worn accelerometer and an open-source scoring algorithm. PA traits also associated with disease severity in PH participants. With further research, these traits may reveal important endurance deficits in this population and could be potential targets for clinical trials. Data Availability All data produced in the present study are available upon reasonable request to the authors. Figure legend PA traits including unbouted MVPA, number and duration of MVPA bouts, and intensity gradient discriminate by functional class (Blue=Functional Class I, Red=Functional Class II). Conflicting interests The Authors declare that there is no conflict of interest. Funding Funding source: NIH K23HL150337 to CMA. 100% of the project support was from federal funding. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. Ethical approval The study was approved by Children’s Hospital Institutional Review Board, protocol #20-017827. Guarantor Catherine M. Avitabile MD Contributorship CMA designed and executed the study and wrote the manuscript. P-WC performed analyses of sensor data, contributed to data interpretation, and edited the manuscript. WF performed statistical analyses and edited the manuscript. BSZ and JAM provided senior mentorship in study design and execution, contributed to data interpretation, and edited the manuscript. Acknowledgments We express our appreciation to all the participants in the study as well as the various study coordinators who supported the study. Footnotes Funding source: NIH K23HL150337 to CMA References 1. ↵ Moledina S , Hislop AA , Foster H , et al. Childhood idiopathic pulmonary arterial hypertension: a national cohort study . Heart . 2010 Sep ; 96 ( 17 ): 1401 – 6 . OpenUrl Abstract / FREE Full Text 2. ↵ van Loon RL , Roofthooft MT , Hillege HL , et al. Pediatric pulmonary hypertension in the Netherlands: epidemiology and characterization during the period 1991 to 2005 . Circulation . 2011 Oct 18; 124 ( 16 ): 1755 – 64 . OpenUrl Abstract / FREE Full Text 3. Barst RJ , McGoon MD , Elliott CG , et al. Survival in childhood pulmonary arterial hypertension: insights from the registry to evaluate early and long-term pulmonary arterial hypertension disease management . Circulation . 2012 Jan 3; 125 ( 1 ): 113 – 22 . OpenUrl Abstract / FREE Full Text 4. ↵ Zijlstra WMH , Douwes JM , Rosenzweig EB , et al. Survival differences in pediatric pulmonary arterial hypertension: clues to a better understanding of outcome and optimal treatment strategies . J Am Coll Cardiol 2014 May 27; 63 ( 20 ): 2159 – 69 . OpenUrl FREE Full Text 5. ↵ Fraisse A , Jais X , Schleich JM , et al. Characteristics and prospective 2-year follow-up of children with pulmonary arterial hypertension in France . Arch Cardiovasc Dis . 2010 Feb ; 103 ( 2 ): 66 – 74 . OpenUrl CrossRef PubMed Web of Science 6. ↵ Ivy DD , Abman S . Beyond the 6-minute walk test for assessing pediatric pulmonary hypertension: making strides through combination end points . Chest . 2015 Sep ; 148 ( 3 ): 576 – 7 . OpenUrl PubMed 7. ↵ Saxer S , Lichtblau M , Berlier C , et al. Physical activity in incident patients with pulmonary arterial and chronic thromboembolic hypertension . Lung . 2019 Oct ; 197 ( 5 ): 617 – 625 . doi: 10.1007/s00408-019-00248-x . Epub 2019 Jul 1. PMID: 31263960 . OpenUrl CrossRef PubMed 8. Mainguy V , Provencher S , Maltais F , et al. Assessment of daily life physical activities in pulmonary arterial hypertension . PLoS One . 2011 ; 6 ( 11 ): e27993 . doi: 10.1371/journal.pone.0027993 . Epub 2011 Nov 16. PMID: 22110770 ; PMCID: PMC3218075 . OpenUrl CrossRef PubMed 9. ↵ Okumus G , Aslan GK , Arseven O , et al. The role of an activity monitor in the objective evaluation of patients with pulmonary hypertension . Clin Respir J . 2018 Jan ; 12 ( 1 ): 119 – 125 . doi: 10.1111/crj.12495 . Epub 2016 May 23. PMID: 27149246 . OpenUrl CrossRef PubMed 10. Ulrich S , Fischler M , Speich R , et al. Wrist actigraphy predicts outcome in patients with pulmonary hypertension . Respiration . 2013 ; 86 ( 1 ): 45 – 51 . doi: 10.1159/000342351 . Epub 2012 Dec 11. PMID: 23234873 . OpenUrl CrossRef PubMed 11. Matura LA , Shou H , Fritz JS , et al. Physical activity and symptoms in pulmonary arterial hypertension . Chest . 2016 Jul ; 150 ( 1 ): 46 - 56 . doi: 10.1016/j.chest.2016.02.633 . Epub 2016 Feb 15. PMID: 26892602 ; PMCID: PMC4980549 . OpenUrl CrossRef PubMed 12. González-Saiz L , Santos-Lozano A , Fiuza-Luces C , et al. Physical activity levels are low in patients with pulmonary hypertension . Ann Transl Med . 2018 Jun ; 6 ( 11 ): 205 . doi: 10.21037/atm.2018.05.37 . PMID: 30023368 ; PMCID: PMC6035982 . OpenUrl CrossRef PubMed 13. ↵ Minhas J , Shou H , Hershman S , et al. Physical activity and its association with traditional outcome measures in pulmonary arterial hypertension . Ann Am Thorac Soc . 2022 Apr ; 19 ( 4 ): 572 – 582 . doi: 10.1513/AnnalsATS.202105-560OC . PMID: 34473938 ; PMCID: PMC8996274 . OpenUrl CrossRef PubMed 14. ↵ Zijlstra WMH , Ploegstra MJ , Vissia-Kazemier T , et al. Physical activity in pediatric pulmonary arterial hypertension measured by accelerometry. A candidate clinical endpoint . Am J Respir Crit Care Med . 2017 Jul 15; 196 ( 2 ): 220 – 227 . doi: 10.1164/rccm.201608-1576OC . PMID: 28178426 . OpenUrl CrossRef PubMed 15. ↵ Chandler JL , Brazendale K , Beets MW , et al. Classification of physical activity intensities using a wrist-worn accelerometer in 8-12-year-old children . Pediatr Obes . 2016 Apr ; 11 ( 2 ): 120 – 7 . doi: 10.1111/ijpo.12033 . Epub 2015 Apr 20. PMID: 25893950 . OpenUrl CrossRef PubMed 16. ↵ Fairclough SJ , Noonan R , Rowlands AV , et al. Wear compliance and activity in children wearing wrist- and hip-mounted accelerometers . Med Sci Sports Exerc . 2016 Feb ; 48 ( 2 ): 245 – 53 . doi: 10.1249/MSS.0000000000000771 . PMID: 26375253 . OpenUrl CrossRef PubMed 17. ↵ Bagot KS , Matthews SA , Mason M , et al. Current, future and potential use of mobile and wearable technologies and social media data in the ABCD study to increase understanding of contributors to child health . Dev Cogn Neurosci . 2018 Aug ; 32 : 121 – 129 . doi: 10.1016/j.dcn.2018.03.008 . Epub 2018 Mar 28. PMID: 29636283 ; PMCID: PMC6447367 . OpenUrl CrossRef PubMed 18. ↵ Koestenberger M , Friedberg MK , Nestaas E , et al. Transthoracic echocardiography in the evaluation of pediatric pulmonary hypertension and ventricular dysfunction . Pulm Circ 2016 ; 6 : 15 – 29 . OpenUrl PubMed 19. ↵ Levy PT , Sanchez Mejia AA , Machefsky A , et al. Normal ranges of right ventricular systolic and diastolic strain measures in children: a systematic review and meta-analysis . J Am Soc Echocardiogr 2014 ; 27 : 549 – 560,e543 . OpenUrl CrossRef PubMed 20. ↵ Burkett DA , Patel SS , Mertens L , et al. Relationship between left ventricular geometry and invasive hemodynamics in pediatric pulmonary hypertension . Circ Cardiovasc Imaging . 2020 ; 13 : e009825 . doi: 10.1161/CIRCIMAGING.119.009825 . Epub 2020 May 15. OpenUrl CrossRef PubMed 21. ↵ Jone PN , Hinzman J , Wagner BD , et al. Right ventricular to left ventricular diameter ratio at end-systole in evaluating outcomes in children with pulmonary hypertension . J Am Soc Echocardiogr . 2014 ; 27 : 172 – 8 . OpenUrl CrossRef PubMed 22. ↵ Avitabile CM , Leonard MB , Zemel BS , et al. Lean mass deficits, vitamin D status and exercise capacity in children and young adults after Fontan palliation . Heart . 2014 Nov ; 100 ( 21 ): 1702 – 7 . doi: 10.1136/heartjnl-2014-305723 . Epub 2014 Jun 27. PMID: 24973081 ; PMCID: PMC4386691 . OpenUrl Abstract / FREE Full Text 23. Avitabile CM , Goldberg DJ , Leonard MB , et al. Leg lean mass correlates with exercise systemic output in young Fontan patients . Heart . 2018 Apr ; 104 ( 8 ): 680 – 684 . doi: 10.1136/heartjnl-2017-311661 . Epub 2017 Oct 7. PMID: 28988207 ; PMCID: PMC7831371 . OpenUrl Abstract / FREE Full Text 24. ↵ Avitabile CM , Saavedra S , Sivakumar N , et al. Marked skeletal muscle deficits are associated with 6-minute walk distance in paediatric pulmonary hypertension . Cardiol Young . 2021 Sep ; 31 ( 9 ): 1426 – 1433 . doi: 10.1017/S1047951121000342 . Epub 2021 Feb 11. PMID: 33568240 . OpenUrl CrossRef PubMed 25. ↵ Avitabile CM , McBride MG , Harris MA , et al. Skeletal muscle deficits are associated with worse exercise performance in pediatric pulmonary hypertension . Front Pediatr . 2022 Oct 5; 10 : 1025420 . doi: 10.3389/fped.2022.1025420 . PMID: 36275051 ; PMCID: PMC9579321 . OpenUrl CrossRef PubMed 26. ↵ Avitabile CM , McBride MG , Zhang X , et al. Peak work rate increases with lower extremity-focused exercise training in adolescents with Fontan circulation . J Am Heart Assoc . 2022 Dec 20; 11 ( 24 ): e027464 . doi: 10.1161/JAHA.122.027464 . Epub 2022 Dec 14. PMID: 36515264 ; PMCID: PMC9798796 . OpenUrl CrossRef PubMed 27. ↵ Ogden CL , Kuczmarski RJ , Flegal KM , et al. Centers for Disease Control and Prevention 2000 growth charts for the United States: improvements to the 1977 National Center for Health Statistics version . Pediatrics . 2002 Jan ; 109 ( 1 ): 45 – 60 . doi: 10.1542/peds.109.1.45 . PMID: 11773541 . OpenUrl CrossRef PubMed Web of Science 28. ↵ Zemel BS , Shepherd JA , Grant SFA , et al. Reference ranges for body composition indices by dual energy X-ray absorptiometry from the Bone Mineral Density in Childhood Study Cohort . Am J Clin Nutr . 2023 Oct ; 118 ( 4 ): 792 – 803 . doi: 10.1016/j.ajcnut.2023.08.006 . Epub 2023 Aug 19. PMID: 37598746 ; PMCID: PMC10579045 . OpenUrl CrossRef PubMed 29. ↵ Cole TJ . The LMS method for constructing normalized growth standards . Eur J Clin Nutr ( 1990 ) 44 : 45 – 60 . OpenUrl PubMed Web of Science 30. ↵ Ploegstra MJ , Ivy DD , Wheeler JG , et al. Growth in children with pulmonary arterial hypertension: a longitudinal retrospective multiregistry study . Lancet Respir Med ( 2016 ) 4 : 281 – 290 . OpenUrl PubMed 31. ↵ Zemel BS , Leonard MB , Kelly A , et al. Height adjustment in assessing dual energy x-ray absorptiometry measurements of bone mass and density in children . J Clin Endocrinol Metab ( 2010 ) 95 : 1265 – 1273 . OpenUrl CrossRef PubMed Web of Science 32. ↵ Dougherty KA , Schall JI , Rovner AJ , et al. Attenuated maximal muscle strength and peak power in children with sickle cell disease . J Pediatr Hematol Oncol . 2011 Mar ; 33 ( 2 ): 93 – 7 . doi: 10.1097/MPH.0b013e318200ef49 . PMID: 21228717 ; PMCID: PMC3078038 . OpenUrl CrossRef PubMed 33. ↵ Avitabile CM , Weber DR , Zemel BS . Paediatric dominant and non-dominant handgrip reference curves and the association with body composition . Ann Hum Biol . 2024 Feb ; 51 ( 1 ): 2298474 . doi: 10.1080/03014460.2023.2298474 . Epub 2024 Jan 22. PMID: 38293777 ; PMCID: PMC11164034 . OpenUrl CrossRef PubMed 34. ↵ Varni JW , Seid M , Rode CA . The PedsQL: measurement model for the pediatric quality of life inventory . Med Care . 1999 Feb ; 37 ( 2 ): 126 – 39 . PMID: 10024117 . OpenUrl CrossRef PubMed Web of Science 35. ↵ ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories . ATS statement: guidelines for the six-minute walk test . Am J Respir Crit Care Med . 2002 Jul 1; 166 ( 1 ): 111 – 7 . doi: 10.1164/ajrccm.166.1.at1102 . Erratum in: Am J Respir Crit Care Med. 2016 May 15;193(10):1185. doi: 10.1164/rccm.19310erratum. PMID: 12091180 . OpenUrl CrossRef PubMed Web of Science 36. ↵ Migueles JH , Rowlands AV , Huber F , et al. GGIR: a research community–driven open-source R package for generating physical activity and sleep outcomes from multi-day raw accelerometer data . J Meas Phys Behav 2019 ; 2 : 188 – 196 . doi: 10.1123/jmpb.2018-0063 . OpenUrl CrossRef 37. ↵ van Hees VT , Fang Z , Langford J , et al. Autocalibration of accelerometer data for free-living physical activity assessment using local gravity and temperature: an evaluation on four continents . J Appl Physiol (1985) . 2014 Oct 1; 117 ( 7 ): 738 – 44 . doi: 10.1152/japplphysiol.00421.2014 . Epub 2014 Aug 7. PMID: 25103964 ; PMCID: PMC4187052 . OpenUrl CrossRef PubMed 38. ↵ van Hees VT , Gorzelniak L , Dean León EC , et al. Separating movement and gravity components in an acceleration signal and implications for the assessment of human daily physical activity . PLoS One . 2013 Apr 23; 8 ( 4 ): e61691 . doi: 10.1371/journal.pone.0061691 . PMID: 23626718 ; PMCID: PMC3634007 . OpenUrl CrossRef PubMed 39. ↵ 39 https://wadpac.github.io/GGIR/articles/chapter3_QualityAssessment.html#non-wear-detection . 40. ↵ van Hees VT , Sabia S , Jones SE , et al. Estimating sleep parameters using an accelerometer without sleep diary . Sci Rep . 2018 Aug 28; 8 ( 1 ): 12975 . doi: 10.1038/s41598-018-31266-z . PMID: 30154500 ; PMCID: PMC6113241 . OpenUrl CrossRef PubMed 41. ↵ Schaefer CA , Nigg CR , Hill JO , et al. Establishing and evaluating wrist cutpoints for the GENEActiv accelerometer in youth . Med Sci Sports Exerc . 2014 Apr ; 46 ( 4 ): 826 – 33 . doi: 10.1249/MSS.0000000000000150 . PMID: 24121241 ; PMCID: PMC3960318 . OpenUrl CrossRef PubMed 42. ↵ Hildebrand M , Hansen BH , van Hees VT , et al. Evaluation of raw acceleration sedentary thresholds in children and adults . Scand J Med Sci Sports . 2017 Dec ; 27 ( 12 ): 1814 – 1823 . doi: 10.1111/sms.12795 . Epub 2016 Nov 22. PMID: 27878845 . OpenUrl CrossRef PubMed 43. ↵ Rowlands AV , Edwardson CL , Davies MJ , et al. Beyond cut points: accelerometer metrics that capture the physical activity profile . Med Sci Sports Exerc . 2018 Jun ; 50 ( 6 ): 1323 – 1332 . doi: 10.1249/MSS.0000000000001561 . PMID: 29360664 . OpenUrl CrossRef PubMed 44. ↵ Barst RJ , Ivy DD , Gaitan G , et al. A randomized, double-blind, placebo-controlled, dose-ranging study of oral sildenafil citrate in treatment-naive children with pulmonary arterial hypertension . Circulation . 2012 Jan 17; 125 ( 2 ): 324 – 34 . doi: 10.1161/CIRCULATIONAHA.110.016667 . Epub 2011 Nov 29. PMID: 22128226 . OpenUrl Abstract / FREE Full Text 45. Barst RJ , Beghetti M , Pulido T , et al ; STARTS-2 Investigators. STARTS-2: long-term survival with oral sildenafil monotherapy in treatment-naive pediatric pulmonary arterial hypertension . Circulation . 2014 May 13;129( 19 ): 1914 – 23 . doi: 10.1161/CIRCULATIONAHA.113.005698 . Epub 2014 Mar 17. PMID: 24637559 . OpenUrl Abstract / FREE Full Text 46. ↵ Collaco JM , Abman SH , Austin ED , et al. Kids Mod PAH trial: A multicenter trial comparing mono-versus duo-therapy for initial treatment of pediatric pulmonary hypertension . Pulm Circ . 2023 Oct 31; 13 ( 4 ): e12305 . doi: 10.1002/pul2.12305 . PMID: 37915400 ; PMCID: PMC10617301 . OpenUrl CrossRef PubMed 47. ↵ Avitabile CM , Krishnan US , Yung D , et al. Actigraphy methodology in the Kids Mod PAH trial: Physical activity as a functional endpoint in pediatric clinical trials . Pulm Circ . 2024 Mar 8; 14 ( 1 ): e12339 . doi: 10.1002/pul2.12339 . PMID: 38464344 ; PMCID: PMC10923039 . OpenUrl CrossRef PubMed 48. ↵ Avitabile CM , Yung D , Handler S , et al. Measurement of physical activity by actigraphy in infants and young children with pulmonary arterial hypertension . J Pediatr . 2023 Nov ; 262 : 113639 . doi: 10.1016/j.jpeds.2023.113639 . Epub2023 Jul 28. PMID: 37517653 ; PMCID: PMC11164018 . OpenUrl CrossRef PubMed 49. ↵ Migueles JH , Cadenas-Sanchez C , Ekelund U , et al. Accelerometer data collection and processing criteria to assess physical activity and other outcomes: a systematic review and practical considerations . Sports Med . 2017 Sep ; 47 ( 9 ): 1821 – 1845 . doi: 10.1007/s40279-017-0716-0 . PMID: 28303543 ; PMCID: PMC6231536 . OpenUrl CrossRef PubMed 50. ↵ Ngueleu AM , Barthod C , Best KL , et al. Criterion validity of ActiGraph monitoring devices for step counting and distance measurement in adults and older adults: a systematic review . J Neuroeng Rehabil . 2022 Oct 17; 19 ( 1 ): 112 . doi: 10.1186/s12984-022-01085-5 . PMID: 36253787 ; PMCID: PMC9575229 . OpenUrl CrossRef PubMed 51. ↵ Neishabouri A , Nguyen J , Samuelsson J , et al. Quantification of acceleration as activity counts in ActiGraph wearable . Sci Rep . 2022 Jul 13; 12 ( 1 ): 11958 . doi: 10.1038/s41598-022-16003-x . PMID: 35831446 ; PMCID: PMC9279376 . OpenUrl CrossRef PubMed 52. ↵ Bianchim MS , McNarry MA , Larun L , et al. Calibration and validation of accelerometry using cut-points to assess physical activity in paediatric clinical groups: A systematic review . Prev Med Rep . 2020 Jun 8; 19 : 101142 . doi: 10.1016/j.pmedr.2020.101142 . PMID: 32637301 ; PMCID: PMC7327836 . OpenUrl CrossRef PubMed 53. ↵ Johansson E , Larisch LM , Marcus C , et al. Calibration and validation of a wrist- and hip-worn Actigraph accelerometer in 4-year-old children . PLoS One . 2016 Sep 12; 11 ( 9 ): e0162436 . doi: 10.1371/journal.pone.0162436 . PMID: 27617962 ; PMCID: PMC5019366 . OpenUrl CrossRef PubMed 54. Chandler JL , Brazendale K , Beets MW , et al. Classification of physical activity intensities using a wrist-worn accelerometer in 8-12-year-old children . Pediatr Obes . 2016 Apr ; 11 ( 2 ): 120 – 7 . doi: 10.1111/ijpo.12033 . Epub 2015 Apr 20. PMID: 25893950 . OpenUrl CrossRef PubMed 55. ↵ Crouter SE , Flynn JI , Bassett DR Jr . Estimating physical activity in youth using a wrist accelerometer . Med Sci Sports Exerc . 2015 May ; 47 ( 5 ): 944 – 51 . doi: 10.1249/MSS.0000000000000502 . PMID: 25207928 ; PMCID: PMC4362848 . OpenUrl CrossRef PubMed 56. ↵ Evenson KR , Catellier DJ , Gill K , Ondrak KS , McMurray RG . Calibration of two objective measures of physical activity for children . J Sports Sci . 2008 Dec ; 26 ( 14 ): 1557 – 65 . doi: 10.1080/02640410802334196 . PMID: 18949660 . OpenUrl CrossRef PubMed Web of Science 57. ↵ Ploegstra MJ , Ferreira RJ , Lokhorst C , et al. Physical activity measured by hip-anchored accelerometry in pediatric pulmonary hypertension: association with disease severity & estimation of minimal important differences . Chest . 2025 Feb 8:S0012-3692(25)00156-4. doi: 10.1016/j.chest.2025.01.038 . Epub ahead of print. PMID: 39929278 . OpenUrl CrossRef PubMed 58. ↵ González-Saiz L , Fiuza-Luces C , Sanchis-Gomar F , et al. Benefits of skeletal-muscle exercise training in pulmonary arterial hypertension: The WHOLEi+12 trial . Int J Cardiol . 2017 Mar 15; 231 : 277 – 283 . doi: 10.1016/j.ijcard.2016.12.026 . PMID: 28189191 . OpenUrl CrossRef PubMed 59. Mainguy V , Maltais F , Saey D , et al. Effects of a rehabilitation program on skeletal muscle function in idiopathic pulmonary arterial hypertension . J Cardiopulm Rehabil Prev . 2010 Sep-Oct ; 30 ( 5 ): 319 – 23 . doi: 10.1097/HCR.0b013e3181d6f962 . PMID: 20410828 . OpenUrl CrossRef PubMed 60. ↵ de Man FS , Handoko ML , Groepenhoff H , et al. Effects of exercise training in patients with idiopathic pulmonary arterial hypertension . Eur Respir J . 2009 Sep ; 34 ( 3 ): 669 – 75 . doi: 10.1183/09031936.00027909 . PMID: 19720810 . OpenUrl Abstract / FREE Full Text 61. ↵ Belcher BR , Wolff-Hughes DL , Dooley EE , et al. US population-referenced percentiles for wrist-worn accelerometer-derived activity . Med Sci Sports Exerc . 2021 Nov 1; 53 ( 11 ): 2455 - 2464 . doi: 10.1249/MSS.0000000000002726 . PMID: 34115727 ; PMCID: PMC8516690 . OpenUrl CrossRef PubMed View the discussion thread. Back to top Previous Next Posted October 28, 2025. Download PDF Data/Code Email Thank you for your interest in spreading the word about medRxiv. NOTE: Your email address is requested solely to identify you as the sender of this article. Your Email * Your Name * Send To * Enter multiple addresses on separate lines or separate them with commas. You are going to email the following Physical activity traits from wrist sensors correlate with clinical status in pediatric pulmonary hypertension Message Subject (Your Name) has forwarded a page to you from medRxiv Message Body (Your Name) thought you would like to see this page from the medRxiv website. Your Personal Message CAPTCHA This question is for testing whether or not you are a human visitor and to prevent automated spam submissions. Share Physical activity traits from wrist sensors correlate with clinical status in pediatric pulmonary hypertension Catherine M. Avitabile , Pin-Wei Chen , Walter Faig , Babette Zemel , Jonathan A. Mitchell medRxiv 2025.10.26.25338733; doi: https://doi.org/10.1101/2025.10.26.25338733 Share This Article: Copy Citation Tools Physical activity traits from wrist sensors correlate with clinical status in pediatric pulmonary hypertension Catherine M. Avitabile , Pin-Wei Chen , Walter Faig , Babette Zemel , Jonathan A. Mitchell medRxiv 2025.10.26.25338733; doi: https://doi.org/10.1101/2025.10.26.25338733 Citation Manager Formats BibTeX Bookends EasyBib EndNote (tagged) EndNote 8 (xml) Medlars Mendeley Papers RefWorks Tagged Ref Manager RIS Zotero Tweet Widget Facebook Like Google Plus One Subject Area Pediatrics Subject Areas All Articles Addiction Medicine (567) Allergy and Immunology (863) Anesthesia (297) Cardiovascular Medicine (4411) Dentistry and Oral Medicine (443) Dermatology (380) Emergency Medicine (606) Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1505) Epidemiology (15205) Forensic Medicine (30) Gastroenterology (1119) Genetic and Genomic Medicine (6574) Geriatric Medicine (666) Health Economics (994) Health Informatics (4511) Health Policy (1365) Health Systems and Quality Improvement (1608) Hematology (537) HIV/AIDS (1263) Infectious Diseases (except HIV/AIDS) (15903) Intensive Care and Critical Care Medicine (1103) Medical Education (620) Medical Ethics (144) Nephrology (666) Neurology (6573) Nursing (345) Nutrition (998) Obstetrics and Gynecology (1139) Occupational and Environmental Health (954) Oncology (3319) Ophthalmology (968) Orthopedics (369) Otolaryngology (420) Pain Medicine (435) Palliative Medicine (129) Pathology (662) Pediatrics (1689) Pharmacology and Therapeutics (691) Primary Care Research (710) Psychiatry and Clinical Psychology (5422) Public and Global Health (9205) Radiology and Imaging (2191) Rehabilitation Medicine and Physical Therapy (1367) Respiratory Medicine (1191) Rheumatology (593) Sexual and Reproductive Health (709) Sports Medicine (529) Surgery (709) Toxicology (99) Transplantation (288) Urology (265) (function(){function c(){var b=a.contentDocument||a.contentWindow.document;if(b){var d=b.createElement('script');d.innerHTML="window.__CF$cv$params={r:'9fe9a00c1a6906eb',t:'MTc3OTI2MjExMg=='};var a=document.createElement('script');a.src='/cdn-cgi/challenge-platform/scripts/jsd/main.js';document.getElementsByTagName('head')[0].appendChild(a);";b.getElementsByTagName('head')[0].appendChild(d)}}if(document.body){var a=document.createElement('iframe');a.height=1;a.width=1;a.style.position='absolute';a.style.top=0;a.style.left=0;a.style.border='none';a.style.visibility='hidden';document.body.appendChild(a);if('loading'!==document.readyState)c();else if(window.addEventListener)document.addEventListener('DOMContentLoaded',c);else{var e=document.onreadystatechange||function(){};document.onreadystatechange=function(b){e(b);'loading'!==document.readyState&&(document.onreadystatechange=e,c())}}}})();

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-06-13T06:42:57.164913+00:00