Highly sensitive enzyme- and amplification-free, quantitative DNA detection using YVO 4 :Eu luminescent nanoparticle probes

preprint OA: closed
📄 Open PDF Full text JSON View at publisher

Abstract

The sensitive detection of nucleic acids is crucial for the accurate diagnosis of infections. In this context, amplification-based methods, such as the quantitative Polymerase Chain Reaction (qPCR) are the gold standard for ultrasensitive DNA or RNA detection and quantification. However, despite its widespread use in developed countries during the COVID-19 pandemic, qPCR remains a costly tool, difficult to implement into low-infrastructure locations. Efforts for the development of alternative tools have yielded high sensitivity approaches but sensitivity is typically reached at the expense of complexity. We here report the development of a simple, sensitive, amplification-, and enzyme-free nucleic acid detection technique using YVO 4 :Eu luminescent nanoparticles. We established an optimized interaction scheme to efficiently reveal target DNA fragments with nanoparticles. By exploiting the extremely strong absorption of the vanadate matrix in the UV to excite the nanoparticles inducing the characteristic Eu 3+ emission at 617 nm via energy transfer, we achieved a highly sensitive (down to 500 particles/mm 2 ; 17,000 particles/well) read-out in standard microplates using a home-made optical reader with light-emitting diode (LED), 275-nm excitation. We reached a 50-aM (30,000 copies/mL) sensitivity for the detection of the 72-base DNA fragment of the SARS-CoV-2 n1 gene. Our new quantitative analytical method detects nucleic acids without amplification with performances close to standard PCR (10,000 copies/mL) 1 , and could be the basis for a transportable alternative for the diagnosis of infectious diseases.
Full text 1,770 characters · extracted from oa-doi-fallback · click to expand
Abstract The sensitive detection of nucleic acids is crucial for the accurate diagnosis of infections. In this context, amplification-based methods, such as the quantitative Polymerase Chain Reaction (qPCR) are the gold standard for ultrasensitive DNA or RNA detection and quantification. However, despite its widespread use in developed countries during the COVID-19 pandemic, qPCR remains a costly tool, difficult to implement into low-infrastructure locations. Efforts for the development of alternative tools have yielded high sensitivity approaches but sensitivity is typically reached at the expense of complexity. We here report the development of a simple, sensitive, amplification-, and enzyme-free nucleic acid detection technique using YVO4:Eu luminescent nanoparticles. We established an optimized interaction scheme to efficiently reveal target DNA fragments with nanoparticles. By exploiting the extremely strong absorption of the vanadate matrix in the UV to excite the nanoparticles inducing the characteristic Eu3+ emission at 617 nm via energy transfer, we achieved a highly sensitive (down to 500 particles/mm2; 17,000 particles/well) read-out in standard microplates using a home-made optical reader with light-emitting diode (LED), 275-nm excitation. We reached a 50-aM (30,000 copies/mL) sensitivity for the detection of the 72-base DNA fragment of the SARS-CoV-2 n1 gene. Our new quantitative analytical method detects nucleic acids without amplification with performances close to standard PCR (10,000 copies/mL)1, and could be the basis for a transportable alternative for the diagnosis of infectious diseases. Competing Interest Statement The authors have declared no competing interest. Footnotes ↵† These authors jointly supervised this work.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-06-13T06:42:57.164913+00:00