Automated Contouring and Planning for Hippocampal-Avoidant Whole-Brain Radiotherapy

preprint OA: closed
📄 Open PDF View at publisher

Abstract

Purpose Design: and evaluate a workflow using commercially available artificial intelligence tools for automated hippocampal segmentation and treatment planning to efficiently generate clinically acceptable hippocampal-avoidant whole brain (HA-WBRT) radiotherapy plans. Methods and Materials We retrospectively identified 100 consecutive adult patients treated for brain metastases outside the hippocampal region. Each patient’s T1 post-contrast brain MRI was processed using FDA-approved software that provides segmentations of brain structures in 5-7 minutes. Automated hippocampal segmentations were reviewed for accuracy and edited manually if necessary, then converted to files compatible with a commercial treatment planning system, where hippocampal avoidance regions and planning target volumes (PTV) were generated. Other organs-at-risk (OARs) were previously contoured per clinical routine. A RapidPlan knowledge-based planning routine was applied for a prescription of 30 Gy in 10 fractions using volumetric modulated arc therapy (VMAT) delivery. Plans were evaluated based on NRG CC001 dose-volume objectives. Results Of the 100 cases, 99 (99%) had acceptable automated hippocampi segmentations without manual intervention. Knowledge-based planning was applied to all cases; the median processing time was 9 minutes 59 seconds (range 6:53 – 13:31). All plans met per-protocol dose-volume objectives for PTV per the NRG CC001 protocol. For comparison, only 66.0% of plans on NRG CC001 met PTV goals per protocol, with 26.3% within acceptable variation. In this study, 43 plans (43%) met OAR constraints, and the remaining 57 (57%) were within acceptable variation, compared to 42.9% and 48.6% on NRG CC001, respectively. No plans in this study had unacceptable dose to OARs, compared to 0.8% of manually generated plans from NRG CC001. Conclusion An automated pipeline harnessing the efficiency of commercially available artificial intelligence tools can generate clinically acceptable VMAT HA-WBRT plans with minimal manual intervention. This process could improve clinical efficiency for a treatment established to improve patient outcomes over standard WBRT.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-06-13T06:42:57.164913+00:00