Incorporating End-Users’ Voices into the Development of an Implant for HIV Prevention: A Discrete Choice Experiment in South Africa and Zimbabwe

preprint OA: closed CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Background: Input from end-users during preclinical phases can support market fit for new HIV prevention technologies. With several long-acting pre-exposure prophylaxis (PrEP) implants in development, we aimed to understand young women’s preferences for PrEP implants to inform optimal design. Methods: . We developed a discrete choice experiment and surveyed 800 young women in Harare, Zimbabwe and Tshwane, South Africa between September-November 2020. Women aged 18 to 30 years who were nulliparous, postpartum, or exchanged sex in prior year were eligible. The DCE asked participants to choose between two hypothetical implants for HIV prevention in a series of nine questions. Implants were described by: size, number of rods and insertion sites, duration (6-months, 1-year, 2-years), flexibility, and biodegradability. Random-parameters logit models estimated preference weights. Results: . Median age was 24 years (interquartile range 21-27). By design, 36% had used contraceptive implants. Duration of protection was most important feature, with strong preference for a 2-year over 6-month implant. In Zimbabwe, the number of rods/insertion sites was second most important and half as important as duration. Nonetheless, to achieve an implant lasting 2-years, 74% were estimated to accept two rods, one in each arm. In South Africa, preference was for longer, flexible implants that required removal, although each of these attributes were one-third as important as duration. On average, biodegradability and size did not influence Zimbabwean women’s choices. Contraceptive implant experience and parity did not influence relative importance of attributes. Conclusions: . While duration of protection was a prominent attribute shaping women’s choices for PrEP implants, other characteristics related to discreetness were relevant. Optimizing for longest dosing while also ensuring minimal detection of implant placement seemed most attractive to potential users.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-27T02:00:06.600101+00:00
License: CC-BY-4.0