Clustering of Circular Consensus Sequences: Accurate Error Correction and Assembly of Single Molecule Real-Time Reads from Multiplexed Amplicon Libraries

preprint OA: closed CC-BY-NC-4.0
📄 Open PDF View at publisher
AI-generated summary by claude@2026-07, 2026-07-15

The C3S-LAA pipeline accurately corrects errors and assembles circular consensus sequences from SMRT reads of pooled amplicons, outperforming the standard Pacific Biosciences long amplicon analysis module.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

BACKGROUND Targeted resequencing with high-throughput sequencing (HTS) platforms can be used to efficiently interrogate the genomes of large numbers of individuals. A critical challenge for research and applications using HTS data, especially from long-read platforms, is errors arising from technological limits and bioinformatic algorithms. RESULTS A single molecule real-time (SMRT) sequencing-error correction and assembly pipeline, C3S-LAA, was developed for libraries of pooled amplicons. By uniquely leveraging the structure of SMRT sequence data (comprised of multiple low quality subreads from which higher quality circular consensus sequences are formed) to cluster raw reads, C3S-LAA produced accurate consensus sequences and assemblies of overlapping amplicons from single sample and multiplexed libraries. In contrast, despite read depths in excess of 100X per amplicon, the standard long amplicon analysis module from Pacific Biosciences generated unexpected numbers of amplicon sequences with substantial inaccuracies in the consensus sequences. A bootstrap analysis showed that the C3S-LAA pipeline per se was effective at removing bioinformatic sources of error, but in rare cases a read depth of nearly 400X was not sufficient to overcome minor but systematic errors inherent to amplification or sequencing. CONCLUSIONS C3S-LAA uses a novel processing algorithm for SMRT amplicon-sequence data that produces accurate consensus sequences and local sequence assemblies. The community standard long amplicon analysis module from Pacific Biosciences is prone to substantial errors that raise concerns about findings based on this pipeline. The method developed here removed this confounding bioinformatics source of error, allowing for the identification of limited instances of errors due to DNA amplification or sequencing.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-27T02:00:06.600101+00:00
License: CC-BY-NC-4.0