The Ability of a Submaximal Cycle Ergometer Test to Detect Longitudinal Changes in VO2Max

preprint OA: closed CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Background: The purpose of the present study was to examine the ability of a submaximal cycling test to detect longitudinal changes in maximal oxygen uptake (VO 2 max) and examine the conformity between changes in measured and estimated VO 2 max over a time span of 5–8 years. Methods A total of 35 participants (21 men and 14 women), aged 29 to 63 years, performed the Ekblom-Bak (EB) submaximal cycle test for estimation of VO 2 max and a maximal treadmill running test for direct measurement of VO 2 max. The baseline tests were conducted between 2009 and 2012, and the follow-up tests were completed 5 to 8 years later. Pearson’s coefficient of correlation ( r ) and paired sample t- test were used to analyse the association between change in measured and estimated VO 2 max. Random and systematic errors between the measured and estimated VO 2 max were evaluated using Bland-Altman plots. Repeated measures ANOVA were used to test differences between changes over time. Results There was no significant change in mean measured VO 2 max between baseline and follow-up ( p  = 0.91), however large individual variations were noted (-0.78 to 0.61 L/min). The correlation between individual change in measured and estimated VO 2 max was r  = 0.75 ( p  < 0.05), and the unstandardised B-coefficient from linear regression modelling was 0.88 (95% CI: 0.61 to 1.15), i.e. , for each litre of change in estimated VO 2 max, the measured value had changed 0.88 L. The correlation between baseline and follow-up errors (the difference between estimated-measured VO 2 max at each occasion) was r  = 0.84 ( p  < 0.05). With regard to the testing procedure, repeated measures ANOVA revealed that there was no significant difference between the group who exercised at the same work rates at baseline and follow-up (n = 25), and those who required a change in work rate (n = 10). Conclusion The EB test detected a change in VO 2 max with reasonably good precision over a time span of 5–8 years. Further studies are needed to evaluate if the test can be used in clinical populations and in subjects with different medications.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-26T02:00:01.498150+00:00
License: CC-BY-4.0