High-Resolution EEG Source Reconstruction from PCA-Corrected BEM-FMM Reciprocal Basis Funcions: A Study with Visual Evoked Potentials from Intermittent Photic Stimulation

preprint OA: closed CC-BY-4.0
📄 Open PDF Full text JSON View at publisher

Abstract

Modern automated human head segmentations can generate high-resolution computational meshes involving many non-nested tissues. However, most source reconstruction software is limited to 3 –4 nested layers of low resolution and a small number of dipolar sources∼ 10, 000. Recently, we introduced modeling techniques for source reconstruction of magnetoencephalographic (MEG) signals using the reciprocal approach and the boundary element fast multipole method (BEM-FMM). The technique of BEM-FMM can process both nested and non-nested models with as many as 4 million surface elements. In this paper, we present an analogue technique for source reconstruction of electroencephalographic (EEG) signals based on cortical global basis functions. The present work uses Helmholtz reciprocity to relate the reciprocally-generated lead-field matrices to their direct counterpart, while resolving the issue of possible biases toward the reference electrode. Our methodology is tested with experimental EEG data collected from a cohort of 12, young and healthy, volunteers subjected to intermittent photic stimulation (IPS). Our novel high-resolution source reconstruction models can have impact on mental health screening as well as brain-computer inter-faces.
Full text 1,437 characters · extracted from oa-doi-fallback · click to expand
Abstract Modern automated human head segmentations can generate high-resolution computational meshes involving many non-nested tissues. However, most source reconstruction software is limited to 3 –4 nested layers of low resolution and a small number of dipolar sources∼ 10, 000. Recently, we introduced modeling techniques for source reconstruction of magnetoencephalographic (MEG) signals using the reciprocal approach and the boundary element fast multipole method (BEM-FMM). The technique of BEM-FMM can process both nested and non-nested models with as many as 4 million surface elements. In this paper, we present an analogue technique for source reconstruction of electroencephalographic (EEG) signals based on cortical global basis functions. The present work uses Helmholtz reciprocity to relate the reciprocally-generated lead-field matrices to their direct counterpart, while resolving the issue of possible biases toward the reference electrode. Our methodology is tested with experimental EEG data collected from a cohort of 12, young and healthy, volunteers subjected to intermittent photic stimulation (IPS). Our novel high-resolution source reconstruction models can have impact on mental health screening as well as brain-computer inter-faces. Competing Interest Statement The authors have declared no competing interest. Footnotes ↵† First two authors share primary authorship. Last two authors share senior authorship.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-05-26T02:00:01.498150+00:00
License: CC-BY-4.0