3D vascular quantitation with application to computational modeling: a pre-clinical light sheet microscopy, high resolution ultrasound, nano-computed tomography comparison study

preprint OA: closed CC-BY-NC-ND-4.0

Abstract

ABSTRACT It is increasingly necessary to both study biology in 3D and obtain quantitative measurements. Not all 3D-reconstructions are created equal, particularly when using the anatomical model as a basis for force calculations, i.e. computational modeling. Here, we compare 3D anatomical reconstructions from two emerging imaging modalities: 4D ultrasound (4DUS) and light sheet fluorescent microscopy (LSFM) against our previous nano-computed tomography (nanoCT) cohort data, using the tortuous highly intricate pharyngeal arch artery system of the chick embryo as a test bed. We highlight modality-specific morphological image acquisition discrepancies and their influence on subsequent computational fluid dynamics results. Overall, LSFM accurately captured quantitative volumetric measurements of small rapidly-changing vascular morphologies while 4DUS systematically inflated small tortuous vessels. Differences in image-based morphology changes led to significant changes in computationally-obtained force magnitudes and flow patterns linked to vessel angle and tortuosity. This validates LSFM as a comparative preclinical vascular quantitative imaging tool and suggests that 4DUS needs extensive 3D anatomical validation for non cardiac chamber vessels.
Full text 1,340 characters · extracted from oa-html · click to expand
ABSTRACT It is increasingly necessary to both study biology in 3D and obtain quantitative measurements. Not all 3D-reconstructions are created equal, particularly when using the anatomical model as a basis for force calculations, i.e. computational modeling. Here, we compare 3D anatomical reconstructions from two emerging imaging modalities: 4D ultrasound (4DUS) and light sheet fluorescent microscopy (LSFM) against our previous nano-computed tomography (nanoCT) cohort data, using the tortuous highly intricate pharyngeal arch artery system of the chick embryo as a test bed. We highlight modality-specific morphological image acquisition discrepancies and their influence on subsequent computational fluid dynamics results. Overall, LSFM accurately captured quantitative volumetric measurements of small rapidly-changing vascular morphologies while 4DUS systematically inflated small tortuous vessels. Differences in image-based morphology changes led to significant changes in computationally-obtained force magnitudes and flow patterns linked to vessel angle and tortuosity. This validates LSFM as a comparative preclinical vascular quantitative imaging tool and suggests that 4DUS needs extensive 3D anatomical validation for non cardiac chamber vessels. Competing Interest Statement The authors have declared no competing interest.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

⚙ Ask this paper AI returns verbatim quotes from the full text · source: oa-html ⓘ

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-05-26T02:00:01.498150+00:00
License: CC-BY-NC-ND-4.0