Clinical impact of patient-prosthesis mismatch after aortic valve replacement with a mechanical or biological prosthesis

preprint OA: closed
View at publisher

Abstract

Objectives: Patient-prosthesis mismatch (PPM) may impair functional capacity and survival after aortic valve replacement (AVR). A mechanical prosthesis tends to have less PPM than a biological prosthesis, but these differences in clinical outcomes remain unclear. This study aimed to investigate the impact of PPM on long-term survival and quality of life (QoL) after mechanical and biological AVRs. Methods: : The presence of PPM was defined in 595 consecutive patients who had undergone isolated AVR. Patients were divided into two groups according to whether they had received a biological or mechanical prosthesis. The groups with and without PPM present were compared with regard to baseline characteristics, operative characteristics, survival, severe complications, freedom from angina and QoL up to 6 years of follow-up. PPM calculation was performed using the EOA value provided by the manufacturer for every prosthesis divided by the patient’s body surface area. Results: : The moderate-to-severe PPM rates were 69.8% and 3.7% after biological and mechanical prostheses implantation, respectively. Patients with a biological prosthesis implanted had mean survival significantly shorter in the PPM group (50.2 months, 95% confidence interval [CI] 45.2-55.3) when compared to the no-PPM group (60.1 months, 95% CI 55.7-64.4) (p = 0.035). In the mechanical prosthesis group, there was no difference in mean survival between the PPM group (66.6 months, 95% CI 58.3-74.9) when compared to the no-PPM group (64.9 months, 95% CI 62.6-67.2) (p = 0.50). The physical score of the QoL questionnaire was significantly lower in the PPM group when compared to the no-PPM group with a biological prosthesis (39.4 ± 8.4 vs. 45.7 ± 10.1, p < 0.001) compared to patients with a mechanical prosthesis (43.9 ± 9.4 vs. 46.9 ± 8.3, p = 0.18). Conclusions: : PPM is common after biological valve implantation and significantly impacts long-term survival and QoL. If the risk of PPM after implantation of a biological prosthesis is suspected, prospective strategies to avoid PPM at the time of operation are warranted.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-06-13T06:42:57.164913+00:00