Clinical Impact of Digitalis Therapy in a Large Multicenter Cohort of CRT‐Recipients

preprint OA: closed CC-BY-4.0
🔓 Open OA copy View at publisher
⚙ AI-generated summary by gemini-2.5-flash-lite, 2026-07-29 ⓘ

Digitalis therapy in CRT recipients showed no impact on all-cause mortality but was associated with reduced CRT response and increased ventricular arrhythmias requiring ICD shocks.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

Abstract

Introduction: Digitalis use in patients with severe heart failure is controversial. We assessed the effects of digitalis therapy on mortality in a large, observational study in recipients of cardiac resynchronization therapy (CRT). Methods: Consecutive patients receiving a CRT-defibrillator in three European tertiary referral centers were enrolled and followed for a median of 28 months. Digitalis use was assessed at the time of CRT implantation. Multivariate Cox-regression model and propensity score matching was used to determine all-cause mortality as primary endpoint. CRT-response (defined as improvement of ≥1 NYHA class), echocardiographic improvement (defined as improvement of LVEF of ≥ 5%), and ICD shocks were assessed as secondary endpoints. Results: The study comprised 552 CRT recipients with standard indications, including 219 patients (40%) treated with digitalis. Compared to patients without digitalis, they had more often atrial fibrillation, poorer LVEF and higher NYHA class (all p ≤ 0.002). Crude analysis of all-cause mortality demonstrated a similar relative risk of death for patients with and without digitalis (HR=1.14; 95% CI 0.88-1.5; p=0.40). After adjustment for independent predictors of mortality, digitalis therapy did not alter the risk for death (adjusted HR=1.04; 95% CI 0.75-1.45; p=0.82). Also, in comparison to 286 propensity score matched patients, mortality was not affected by digitalis intake (propensity adjusted HR=1.11; 95% CI 0.72-1.70; p=0.64). CRT response was predominant in digitalis non-users concerning both improvement of HF symptoms and LVEF (NYHA p<0.01; LVEF p<0.01) while patients on digitalis had more often ventricular tachyarrhythmias requiring ICD shock (p=0.01). Conclusions: Digitalis therapy had no effect on mortality but did negatively affect CRT response and susceptibility to ventricular arrhythmias requiring ICD shock treatment.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-26T02:00:01.498150+00:00
License: CC-BY-4.0