Accuracy of Intraoperative Estimation of Femoral Stem Anteversion in Cementless Total Hip Arthroplasty by Using a Digital Protractor and a Spirit Level

preprint OA: closed CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Abstract Introduction: The femoral component anteversion during surgery is traditionally assessed by a visual assessment of the surgeon and has proven to be imprecise. We sought to determine the accuracy of a digital protractor and a spirit level to measure the stem anteversion during cementless THA.Methods: A prospective study was conducted among 107 patients (114 hips) who underwent primary cementless THA via posterolateral approach. A pipe with a spirit level was attached to the tibial tubercle and intermalleolar midpoint. While the leg was held perpendicularly to the floor, stem anteversion was estimated by 3 methods: method A by visual assessment; method B by a digital protractor alone; and method C by a digital protractor combined with a spirit level. The angles were compared with the true anteversion measured by postoperative CT scan.Results: The average anteversion by method C (22.8° ± 6.9°, range -2° to 40°) was significantly lower than method A (24.6° ± 5.2°, range 0° to 30°) (p=0.033), but not different from the true anteversion (22.1° ± 8.2°, range -5.4° to 43.1°) (p=0.445). There were no significant differences between method B (23.2° ± 8.2°, range -4° to 45°) and method A, C or the true anteversion. The mean deviation of the intraoperative estimation from the true anteversion was 0.8° ± 3.7° (range -7.1° to 8.0°) by method C; 1.2° ± 5.1° (range -8.8° to 14.3°) by method B; and 2.5° ± 7.4° (range -19.0° to 16.0°) by method A. Estimation error within 5° was found in 107 hips (93.9%) with method C; 86 hips (75.4%) with method B; and 59 hips (51.8%) with method A.Conclusion: Accurate estimation of stem anteversion during cementless THA can be determined intraoperatively by the use of a digital protractor and a spirit level. Trial registration: Thai Clinical Trials Registry (TCTR 20180326003). Registered on 20 March 2018. Retrospectively registered. http://www.clinicaltrials.in.th/index.php?tp=regtrials&menu=trialsearch&smenu=fulltext&task=search&task2=view1&id=3375

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-26T02:00:01.498150+00:00
License: CC-BY-4.0