Can mobile-bearing unicompartmental knee arthroplasty achieve natural gap-balancing: an observational study with novel pressure sensor
preprint
OA: closed
CC-BY-4.0
Abstract
Background: Mobile-bearing unicompartmental knee arthroplasty (MB-UKA) is an effective treatment for anteromedial knee osteoarthritis. Meticulous intraoperative soft tissue balancing remains challenging yet consequential for a successful operation. Currently, surgeons rely mostly on their experience during soft tissue balancing, yielding unreproducible results. This study aimed to further optimize clinical results of MB-UKA through quantitative measurements of intraoperative medial compartment soft tissue tension and determination of target tension values most consistent with the natural state. Methods: This was an observational study of 24 consecutive patients. All 30 UKAs were performed by a single surgeon. The piezoresistive sensor was custom designed to fit in the medial compartment gap. Contact pressures were measured at 5 angular positions of the knee intraoperatively: 0°, 20°, 45°, 90°, and 110° of flexion. The change in pressure from extension (20° position) and flexion (110° position) was also calculated (E-FPD). Data on age, sex, body mass index, operative side, and bearing size were collected. Outcome measures were measured at baseline and at the 6-month postoperative follow-up; Oxford Knee Score, visual analog scale score, and range of motion were compared to evaluate clinical outcomes. Results: There was a significant improvement in patients in all measured outcomes at 6 months from baseline. The E-FPD of 14.9 N (8.9, 24.6) was indicative of appropriate soft tissue balancing throughout the functional range of knee motion. Of 30 knees, 22 were 3-mm bearing and 8 were 4- or 5-mm bearing. The pressure data of the 3-mm bearing group was larger than that of the non-3-mm bearing group for each knee flexion degree, but the difference was not statistically significant. Conclusions: Objective data from sensor output may assist surgeons in decreasing loading variability during MB-UKA. The data suggested that MB-UKA could not accurately restore soft tissue tension to the natural state, which was related to the inability of MB-UKA surgical instruments to fine adjust the bone cut and soft tissue release. We suggest designing a new type of 3.5 G-clamp to help better obtain the soft tissue tension close to the natural tension. Study registration: Chinese Clinical Trial Registry (http://www.chictr.org.cn): ChiCTR1900024146.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00
- unpaywall
- last seen: 2026-05-26T02:00:01.498150+00:00
License: CC-BY-4.0