Carbon Cybernetics Array: a miniaturized carbon-based microelectrode array for intracortical recording

preprint OA: closed CC-BY-NC-ND-4.0
📄 Open PDF Full text JSON View at publisher

Abstract

ABSTRACT Implantable brain-machine interfaces, capable of capturing high-resolution neural signals, hold great promise for treating neurological conditions and advancing neuroscience research. As the field moves toward chronic, fully implantable systems, ensuring the long-term safety and stability of the microelectrode arrays, the core component of these interfaces, remains a significant challenge. Hermetic sealing, which prevents moisture and contaminants from entering the device, is a critical yet often overlooked factor in array designs. This study reports the Carbon Cybernetics Array, a hermetically sealed, carbon-based microelectrode array for neural interfacing. Carbon fiber electrodes are anchored on a diamond substrate via a hermetic feedthrough structure, with hermeticity validated through helium leak testing. These ultrathin and flexible carbon fibers require minimal insertion force, cause little tissue damage after six months of implantation in rats and enable single-unit neural recordings. Furthermore, a low-cost, manually controllable insertion toolset is developed for precise array implantation in the sheep brain through a small burr hole, demonstrating a step toward clinical translation. Finally, the scalability of the fabrication approach is exemplified by arrays with over 1000 fibers. Together, this hermetically sealed feedthrough structure will lay the foundation for a future fully implantable device with wireless capabilities.
Full text 1,922 characters · extracted from oa-doi-fallback · click to expand
ABSTRACT Implantable brain-machine interfaces, capable of capturing high-resolution neural signals, hold great promise for treating neurological conditions and advancing neuroscience research. As the field moves toward chronic, fully implantable systems, ensuring the long-term safety and stability of the microelectrode arrays, the core component of these interfaces, remains a significant challenge. Hermetic sealing, which prevents moisture and contaminants from entering the device, is a critical yet often overlooked factor in array designs. This study reports the Carbon Cybernetics Array, a hermetically sealed, carbon-based microelectrode array for neural interfacing. Carbon fiber electrodes are anchored on a diamond substrate via a hermetic feedthrough structure, with hermeticity validated through helium leak testing. These ultrathin and flexible carbon fibers require minimal insertion force, cause little tissue damage after six months of implantation in rats and enable single-unit neural recordings. Furthermore, a low-cost, manually controllable insertion toolset is developed for precise array implantation in the sheep brain through a small burr hole, demonstrating a step toward clinical translation. Finally, the scalability of the fabrication approach is exemplified by arrays with over 1000 fibers. Together, this hermetically sealed feedthrough structure will lay the foundation for a future fully implantable device with wireless capabilities. Competing Interest Statement SH and SLCA were formerly employees of Carbon Cybernetics Pty Ltd. (Melbourne), a company that was developing diamond and carbon-based medical device components. SLCA, MRI, RH, MIM, DJG and SP are shareholders and/or officers of Carbon Cybernetics Canada Ltd. SP was previously a shareholder in iBIONICS, a company developing a diamond-based retinal implant. All authors declare that they have no other competing interests.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: oa-doi-fallback

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2026) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-05-26T02:00:01.498150+00:00
License: CC-BY-NC-ND-4.0