SARS-CoV-2 air and surface contamination on a COVID-19 ward and at home
preprint
OA: gold
CC-BY-4.0
Abstract
SARS-CoV-2 has been detected both in air and on surfaces, but questions remain about the patient-specific and environmental factors affecting virus transmission to the environment. Additionally, more detailed information on viral findings in air is needed. This cross-sectional study presents results from 259 air and 252 surface samples from the surroundings of 23 hospitalized and eight home-treated COVID-19 patients between July 2020 and March 2021 and compares the results between the measured environments and patient factors. The proportions of PCR-positive air and surface samples showed statistical similarity in hospital and in the home. In four cases, positive environmental samples were detected even after the patients had developed a neutralizing IgG response. SARS-CoV-2 RNA was detected in the following particle sizes: 0.65–4.7 µm, >7 µm, >10 µm, and <100 µm. Appropriate infection control against airborne and surface transmission routes is needed in both environments, even after antibody production has begun.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.