Experimental comparison of non-contact and tactile R-test instruments in dynamic measurement | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Research Article Experimental comparison of non-contact and tactile R-test instruments in dynamic measurement Soichi Ibaraki, Koki Onodera, Wen-Yuh Jywe, Chia-Ming Hsu, Yu-Wei Chang This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-2713610/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 07 Sep, 2023 Read the published version in The International Journal of Advanced Manufacturing Technology → Version 1 posted 4 You are reading this latest preprint version Abstract The R-Test measures the three-dimensional displacement of a tool center point with respect to a work table in five-axis machine tool, as linear axes are driven synchronously with a rotary axis. This paper experimentally compares the measuring performance of the R-Test instruments with 1) tactile linear displacement sensors, 2) laser displacement sensors based on the refraction in a glass ball lens (Laser R-Test), and 3) laser interferometers, in dynamic tests described in ISO 10791-6:2014. A tactile displacement sensor pushes its measuring contact to the target surface by a spring, and its stiffness can limit the measurement bandwidth. This paper experimentally investigates this influence in the measurement of dynamic synchronization error of rotary and linear axes particularly near the reversal point in the present tests. This paper also presents a test to measure the bandwidth of a tactile displacement sensor. R-Test five-axis machine tools dynamic measurement geometric errors Full Text Cite Share Download PDF Status: Published Journal Publication published 07 Sep, 2023 Read the published version in The International Journal of Advanced Manufacturing Technology → Version 1 posted Reviewers invited by journal 28 Apr, 2023 Reviewers agreed at journal 28 Mar, 2023 Editor assigned by journal 20 Mar, 2023 First submitted to journal 20 Mar, 2023 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-2713610","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Research Article","associatedPublications":[],"authors":[{"id":187094330,"identity":"c1e27e71-3456-4061-b6dc-420c0d6f38fa","order_by":0,"name":"Soichi Ibaraki","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAABB0lEQVRIiWNgGAWjYBACNgkQeUBCzoAZSDM2SMBlmAlpMSZeCwNEC0PiBgawFiIcxifd/OzDjzMW6dvZeR8+/LnDIpq/gceA4UcNA7s5LofJHDOe2XNDIndnM7uxMe8ZidwZB3gMGHuOMTBb4rCSTSLBmIHng0TuhsNsbNKMbRK5DfffGDDwNjAwGxzApSX9M+OfDxLpBkAtkj+BWuaDbPmLV0uOMTPPDYkEkBYJXqCWDUAtzHhtkTlTzCxzRsIQ6DBmY5CWjQfYCg7LHJPA6Rf52e2bGd8cq5M3OH+M8eHPtrrceQeYNz58U2OTjCvEsAOgkySSDUjSAgJ2pGsZBaNgFIyCYQoAfs9SNJmu3igAAAAASUVORK5CYII=","orcid":"https://orcid.org/0000-0002-3527-2036","institution":"Kyoto University","correspondingAuthor":true,"submittingAuthor":false,"prefix":"","firstName":"Soichi","middleName":"","lastName":"Ibaraki","suffix":""},{"id":187094331,"identity":"74485e77-d388-42a5-8d00-f1d97e8b0c3d","order_by":1,"name":"Koki Onodera","email":"","orcid":"","institution":"","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Koki","middleName":"","lastName":"Onodera","suffix":""},{"id":187094332,"identity":"3199cf22-2573-4f5c-8112-feff599b5f69","order_by":2,"name":"Wen-Yuh Jywe","email":"","orcid":"","institution":"","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Wen-Yuh","middleName":"","lastName":"Jywe","suffix":""},{"id":187094333,"identity":"c20505db-e8b2-45d1-b158-0c94ea7934a0","order_by":3,"name":"Chia-Ming Hsu","email":"","orcid":"","institution":"","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Chia-Ming","middleName":"","lastName":"Hsu","suffix":""},{"id":187094334,"identity":"97b03142-a009-46c9-9433-6fe88f7c2dc3","order_by":4,"name":"Yu-Wei Chang","email":"","orcid":"","institution":"","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Yu-Wei","middleName":"","lastName":"Chang","suffix":""}],"badges":[],"createdAt":"2023-03-20 10:45:29","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-2713610/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-2713610/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1007/s00170-023-12178-3","type":"published","date":"2023-09-07T15:09:54+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":42948043,"identity":"988da50d-7120-404c-b5b0-d1f7669274a0","added_by":"auto","created_at":"2023-09-11 15:12:19","extension":"pdf","order_by":1,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":630720,"visible":true,"origin":"","legend":"","description":"","filename":"ijamt20onodera.pdf","url":"https://assets-eu.researchsquare.com/files/rs-2713610/v1_covered_119dc753-2f27-47c1-b5b9-5c66a748353f.pdf"}],"financialInterests":"","formattedTitle":"Experimental comparison of non-contact and tactile R-test instruments in dynamic measurement","fulltext":[],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":false,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":true,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":true,"isPdf":true,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"
[email protected]","identity":"the-international-journal-of-advanced-manufacturing-technology","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"jamt","sideBox":"Learn more about [The International Journal of Advanced Manufacturing Technology](https://www.springer.com/journal/170)","snPcode":"170","submissionUrl":"https://submission.nature.com/new-submission/170/3","title":"The International Journal of Advanced Manufacturing Technology","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"em","reportingPortfolio":"Springer Hybrid","inReviewEnabled":true,"inReviewRevisionsEnabled":false},"keywords":"R-Test, five-axis machine tools, dynamic measurement, geometric errors","lastPublishedDoi":"10.21203/rs.3.rs-2713610/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-2713610/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"The R-Test measures the three-dimensional displacement of a tool center point with respect to a work table in five-axis machine tool, as linear axes are driven synchronously with a rotary axis. This paper experimentally compares the measuring performance of the R-Test instruments with 1) tactile linear displacement sensors, 2) laser displacement sensors based on the refraction in a glass ball lens (Laser R-Test), and 3) laser interferometers, in dynamic tests described in ISO 10791-6:2014. A tactile displacement sensor pushes its measuring contact to the target surface by a spring, and its stiffness can limit the measurement bandwidth. This paper experimentally investigates this influence in the measurement of dynamic synchronization error of rotary and linear axes particularly near the reversal point in the present tests. This paper also presents a test to measure the bandwidth of a tactile displacement sensor.","manuscriptTitle":"Experimental comparison of non-contact and tactile R-test instruments in dynamic measurement","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2023-03-29 11:48:03","doi":"10.21203/rs.3.rs-2713610/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"reviewersInvited","content":"","date":"2023-04-28T19:21:39+00:00","index":"","fulltext":""},{"type":"reviewerAgreed","content":"","date":"2023-03-28T08:45:38+00:00","index":0,"fulltext":""},{"type":"editorAssigned","content":"","date":"2023-03-21T02:33:07+00:00","index":"","fulltext":""},{"type":"submitted","content":"The International Journal of Advanced Manufacturing Technology","date":"2023-03-20T06:45:16+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"
[email protected]","identity":"the-international-journal-of-advanced-manufacturing-technology","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"jamt","sideBox":"Learn more about [The International Journal of Advanced Manufacturing Technology](https://www.springer.com/journal/170)","snPcode":"170","submissionUrl":"https://submission.nature.com/new-submission/170/3","title":"The International Journal of Advanced Manufacturing Technology","twitterHandle":"","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"em","reportingPortfolio":"Springer Hybrid","inReviewEnabled":true,"inReviewRevisionsEnabled":false}}],"origin":"","ownerIdentity":"8ece5924-78fc-4703-beb2-5b458ef0d7f8","owner":[],"postedDate":"March 29th, 2023","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[],"tags":[],"updatedAt":"2023-09-11T15:11:49+00:00","versionOfRecord":{"articleIdentity":"rs-2713610","link":"https://doi.org/10.1007/s00170-023-12178-3","journal":{"identity":"the-international-journal-of-advanced-manufacturing-technology","isVorOnly":false,"title":"The International Journal of Advanced Manufacturing Technology"},"publishedOn":"2023-09-07 15:09:54","publishedOnDateReadable":"September 7th, 2023"},"versionCreatedAt":"2023-03-29 11:48:03","video":"","vorDoi":"10.1007/s00170-023-12178-3","vorDoiUrl":"https://doi.org/10.1007/s00170-023-12178-3","workflowStages":[]},"version":"v1","identity":"rs-2713610","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-2713610","identity":"rs-2713610","version":["v1"]},"buildId":"WrCJVZZCHTDjtuVLN7oU0","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.