Methods
and Materials: Pancreata from five human donors were included.
Immediately after removal from the donor each pancreas was perfused with
histidine-tryptophan-ketoglutarate (HTK) solution and stored in hypothermic
condition (4oC). 31P-MRS was performed on a 1.5 T clinical MR scanner, using
an ISIS sequence. Typical voxel size was ~5×5×14 cm 3. The first spectrum
was acquired 6-10 hours after HTK perfusion start. During the following 17-25
hours subsequent spectra were obtained by repeated examinations, while
preserving the hypothermic environment. Thereafter the pancreas was
exposed to room temperature for 24 hours and the last spectrum was
measured. This spectrum served as a reference for non-viable tissue. The
following metabolites were fitted: phosphomonoesters (PME), inorganic
phosphate (Pi), phosphodiesters (PDE), phosphocreatine (PCr), and
adenosine triphosphate (ATP).
Results
3-ATP and 2-ATP lines decreased to the noise level within 2-4 hours
after the start of
31P-MRS. PME, PDE and '-ATP levels gradually decreased
and Pi increased. Non-viable pancreas tissue revealed dominant Pi and small
PME and PDE intensities.
Conclusion
( 3-ATP+2-ATP)/Pi, PME/Pi and PDE/Pi spectral intensity ratios
obtained by
31P-MRS are promising quantitative parameters for objective non-
invasive assessment of the viability of human pancreas grafts.
B-0002 10:39
Utility of DWI sequences in autoimmune pancreatitis before and after
steroid therapy
B. Pedrinolla, A. Cybulski, R. Negrelli, S. Mehrabi, R. Manfredi, R. Pozzi-
Mucelli; Verona/IT (
[email protected])
Purpose: To evaluate the utility of Diffusion Weighted (DWI) sequences in
Autoimmune Pancreatitis (AIP) and to identify typical values of apparent
diffusion coefficients (ADC) before and after steroid therapy.
Methods
and Materials: Between February 2010 and April 2013 we evaluated
retrospectively 35 Magnetic Resonance examination with Diffusion Weighted
Imaging (DWI) Sequences in 25 patients with diagnosis of AIP (19 men, 6
women, mean age 45.7 years). Ten out of 25 patients performed MRI before
and after steroid therapy, 3/25 only before and 12/25 only after therapy. Two
Radiologists separately analysed each exam, evaluating the signal ntensity of
the affected parenchyma in T1-weighted and DWI sequences and measuring
ADC values, through circular region of interest.
Results
In the acute phase AIP appeared hypointense in T1 sequences in
13/13 (100%) and hyperintense in 11/13 (84.6%) patients, with an ADC value
of 1.12±0.19x10
-3 mm2/s; after steroid treatment the signal intensity remained
hypointense on T1 sequences in 16/22 (72.7%) and decreased in DWI in 17/22
patients (77.3%) with an ADC of 1.44 ±0.16x10
-3 mm2/s, statistically
different from the acute phase value (p=0.0002).
Conclusion
AIP shows a low signal intensity on T1 sequences, an high signal
intensity on DWI and a low ADC value in the acute phase. After steroid
treatment, signal intensity on T1 sequences remains low in the most of the
cases, but intensity signal in DWI decreases and ADC value increases,
reflecting disease activity. DWI and ADC are qualitative and quantitative
complementary parameters in evaluation of response to treatment in AIP.
B-0003 10:48
Stenosis of the main pancreatic duct in focal form of autoimmune
pancreatitis: imaging findings on MR-MRCP
R. Negrelli, E. Boninsegna, B. Pedrinolla, A. Ventriglia, C. Sozzi, S. Mehrabi,
R. Manfredi, R. Pozzi-Mucelli; Verona/IT (
[email protected])
Purpose: To retrospectively evaluate the MR imaging-MR
cholangiopancreatographic (MRCP) findings of focal forms of autoimmune
pancreatitis (AIP) and to describe ductal system involvement at diagnosis.
Methods
and Materials: MR examinations of 123 patients affected from AIP
were considered for inclusion. Out of these cases, we included 26 patients who
satisfied International Consensus Diagnostic Criteria and were suffering from
focal form of AIP. MRI was performed as a technique for the first diagnosis; all
the patients who underwent other imaging techniques were excluded. Image
analysis included: site of pancreatic parenc hymal enlargement, signal intensity
abnormalities, pancreatic enhancement, main pancreatic duct (MPD) diameter,
MPD stenosis, presence of upstream and side branches dilation.
Results
signal intensity abnormalities were localised in the head in 10/26
(38.5%) patients, in the body-tail in 16/26 (61.5%) patients. Lesions showed
hypointensity on T1-weighted images in all 26 patients, hyperintensity on T2-
weighted images in 22/26 (84.6%) cases. The affected parenchyma was
hypovascular during the arterial phase in 25/26 (96.2%) patients with contrast
retention in all patients. MRCP study showed a single MPD stenosis in 12/26
(46.1%) patients and multiple stenoses in 14/26 (53.8%), without an upstream
dilation of the MPD (mean value: 3.83 mm).
Conclusion
MR and MRCP are effective technique for the diagnosis of AIP,
through the finding of indicative signs of the disease, such as the absence of
the physiological lobulation and the typical contrastographic appearance,
(hypovascular during arterial phase with progressive retention of contrast). The
presence of multiple stenoses at MRCP suggests the diagnosis of AIP.
B-0004 10:57
Indication to the use of secretin-enhanced MRCP: experience of a single
large referral center
E. Boninsegna, R. Negrelli, B. Pedrinolla, S. Mehrabi, R. Manfredi, R. Pozzi-
Mucelli; Verona/IT (
[email protected])
Purpose: To retrospectively evaluate the diagnostic utility of secretin-
enhanced MR cholangiopancreatography (S-MRCP) in various pancreas
conditions.
Methods
and Materials: 314 S-MRCP examinations performed on 299
patients in our center in 2012 were analysed. We evaluated the diagnostic role
of S-MRCP in patients with suspected or diagnosed chronic pancreatitis,
severe acute pancreatitis, pancreatoduodenectomy, asymptomatic pancreatic
hyperenzymaemia, suspected solid or cystic tumour. MRCP findings before
and after Secretin administration were compared.
Results
S-MRCP compared to MRCP found 34.2% (49/143) additional
patients with mild-chronic pancreatitis ( P
< 0.01); in 71 patients with already
diagnosed chronic pancreatitis secreti n was useful to assess pancreatic
exocrine reserve (70% Sensibility, 95% Specificity) and to evaluate the
efficiency of pancreatic sphincterotomy (performed in 16/71 patients, 22.5%);
S-MRCP found pancreatic leakage in 12.5% of Patients (3/24) with acute
pancreatitis ( P=0.23); S-MRCP found anastomotic stenosis in 33.3% of
patients with pancreatoduodenectomy (3/9, P=0.21); in the group with
asymptomatic hyperenzymaemia S-MRCP showed mild-chronic pancreatitis in
66.7% of patients (8/12, P
< 0.01); in 17 patients with main pancreatic duct
stenosis S-MRCP differentiated inflammatory pancreatic mass from pancreatic
carcinomas (100% Sensibility, 92% Specificity). In 19 patients with suspected
cystic tumour S-MRCP was not diagnostically superior to MRCP.
Conclusion
Secretin-enhanced MRCP gives valuable information of the
function and anatomy of the pancreas. It is useful to detect signs of mild-
chronic pancreatitis, assess pancreatic exocrine reserve, demonstrate
pancreatic leakage, evaluate results of pancreatoduodenectomy and
sphincterotomy, differentiate inflammatory pancreatic mass from pancreatic
carcinomas.
B-0005 11:06
Pancreatic steatosis in a population-based study and its clinical
relevance determined by magnetic resonance imaging
F. Berthold
1, J. Mayerle1, H. Völzke1, S.B. Reeder2, N. Hosten1, B. Mensel1,
K. Hegenscheid1, P. Meffert1, J.-P. Kühn1; 1Greifswald/DE, 2Madison, WI/US
(
[email protected])
Purpose: To assess the pancreatic fat content and to investigate its clinical
relevance within a population-based study using a quantitative confounder-
corrected MRI method to measure tissue proton density fat-fraction (PDFF).
Methods
and Materials: MRI was performed at 1.5 T including a multi-echo
chemical shift-encoded sequence. PDFF-maps were calculated after correction
for T1-bias, T2*-bias, multi-peak spectral complexity of fat and noise bias. A fat
phantom was constructed to evaluate the PDFF over the range from 0 to
S137
B A C D E F G
Thursday
100%. In addition, 1,367 asymptomatic volunteers, consistent of 633 men 743
women, with a median age of 50 years were grouped into non-diabetics
(1083), prediabetics (208) and non-treated type 2 diabetics (76) following the
oral glucose tolerance test. PDFF was assessed in pancreatic head, body and
tail for each subject. Multi-variate analysis was performed to compare PDFF
with demographic factors, behavioural factors and laboratory data associated
with the metabolic syndrome.
Results
There was excellent agreement between fat content of phantom and
PDFF (r2=0.989) with no differences in slope (p=0.471) and intercept
(p=0.449). In volunteers, the mean-adjusted pancreatic fat content was 4.4%
(head 4.6%; body 4.9%; tail 3.8%; being unequally distributed, p=0.0008).
There was no significant difference between non-diabetic, prediabetic and type
2 diabetic subjects (p=0.757). Pancreatic PDFF was correlated with age, body
mass index (BMI) and serum lipase activity, however (P < 0.001).
Conclusion
MRI is a useful tool to quantify the pancreatic steatosis.
Pancreatic fat is not related to prediabetes and diabetes, which implicates a
limited clinical relevance in the content of the glycaemic status.
B-0006 11:15
MDCT based volumetric analysis for evaluation of pancreas regeneration
following distal pancreatic resection
T. Zahel, V. Phillipp, H. Algül, E.J. Rummeny, M. Dobritz;
Munich/DE (
[email protected])
Purpose: To analyse pancreatic volume after distal pancreatic resection using
a semi-automatic volume software and MDCT-scans.
Methods
and Materials: Residual pancreatic volumes of 25 patients who had
undergone distal pancreatic resection (for benign and malignant reasons) were
determined 2 weeks, 8 weeks, and 6 months after surgery. CT scans were
obtained in the portal-venous phase (5 mm, 256-slice CT scanner). A semi-
automatic volume analysis software with" tumor-tracking" function was used.
Results
Pancreatic volume was determined semi-automatically within
5 minutes for one examination. Mean pancreatic volume of 25 patients (mean
age 63.0 years) was 33.9 ml, 39.2 ml, and 40.5 ml; 2 weeks, 8 weeks, and 6
months after surgery, respectively. Si gnificant increase of pancreatic volume
was already seen 8 weeks after surgery (Wilcoxon's signed rank, p=0.001*).
Six months after surgery pancreatic volume was significantly higher than 2
weeks after surgery (Wilcoxon's signed rank, p=0.002*). Thus, between 8
weeks and 6 months after surgery further volume increase was found
(p=0.0004*).
Conclusion
MDCT based volumetric analysis is a fast and suitable method
for evaluation of pancreas volume following distal pancreatic resection.
Furthermore, pancreas volume shows a tendency to increase already 8 weeks
after surgery.
B-0007 11:24
Detection of active bile leak with Gd-EOB-DTPA-enhanced MR
cholangiography: comparison of 20-25 min delayed and 60-180 min
delayed images
A. Cieszanowski, A. Stadnik, A. Lezak, E. Maj, K. Zieniewicz,
K. Rowinska-Berman, I.P. Grudzinski, M. Krawczyk, O. Rowinski; Warsaw/PL
(
[email protected])
Purpose: To assess the value of contrast-enhanced magnetic resonance
cholangiography (MRC) performed in different time delays after injection of
gadoxetic acid disodium (Gd-EOB-DTPA) for the diagnosis of active bile leak.
Methods
and Materials: This retrospective analysis included Gd-EOB-DTPA-
enhanced MR images of 34 patients suspected of bile leak. Images were
acquired 20-25 min after Gd-EOB-DTPA injection. If there was inadequate
contrast in the bile ducts, then delayed images after 60-90 min and 150-
180 min were obtained. Results were correlated with intraoperative findings,
ERCP results, clinical data, laboratory tests, and follow-up examinations.
Results
Gd-EOB-DTPA-enhanced MRC yielded an overall sensitivity of
96.4%, specificity of 100% and accuracy of 97.1% for the diagnosis of an
active bile leak. The sensitivity of 20-25 min delayed MR images was 42.9%, of
combined 20-25 min and 60-90 min delayed images was 92.9% and of
combined 20-25 min, 60-90 min and 150-180 min delayed images was 96.4%.
Conclusion
Gd-EOB-DTPA-enhanced MRC utilising delayed phase images
was effective for detecting the presence and location of active bile leaks. The
images acquired 60-180 min post-injection enabled identification of bile leaks
even in patients with a dilated biliary system or moderate liver dysfunction.
B-0008 11:33
Xanthogranulomatous cholecystitis: which is the best image tool to
differentiate it from gallbladder carcinoma?
E. Lee, J. Kim, I. Joo, J. Lee, J. Han, B. Choi; Seoul/KR
(
[email protected])
Purpose: To evaluate diagnostic performance and common findings of high-
resolution ultrasound (HRUS), CT, MRI to differentiate xanthogranulomatous
cholecystitis (XGC) from early flat-type gallbladder (GB) cancer.
Methods
and Materials: From January 2000 to May 2012, patients with
surgically proven XGC (n=40) and early GB cancer (T1 or T2) with flat or
infiltrative type (n=46), who underwent at least one imaging study amongst the
HRUS (combined low- and high-MHz transducers, n=43), CT (n=83), or MRI
(n=34) were included this study. Two radiologists independently and
retrospectively estimated the possibility of XGC or GB cancer in each imaging
modality using a five-point scale. They also evaluated the presence or absence
of predefined abnormal findings of the gallbladder on HRUS, CT, and MRI.
Statistical analyses were performed using ROC analysis and Fisher's exact
test.
Results
AUCs of HRUS, CT and MR to differentiate XGC from GB cancer
were more than 0.8 in R1 and R2 with moderate to excellent agreement.
Statistically common HRUS findings for XGC included diffuse and smooth wall
thickening, intramural nodule, gallstone, and collapsed GB (p < 0.01).
Statistically common CT findings for XGC included diffuse and smooth wall
thickening, continuous mucosa, intramural nodule, heterogeneously thick
single layer, transient hepatic atten uation difference, and pericholecystic
infiltration (p < 0.01). Statistically common MRI findings for XGC included
diffuse wall thickening, continuous mucosa, intramural nodule,
heterogeneously thick single layer, and transient hepatic signal difference
(p < 0.01).
Conclusion
All three modalities of HRUS, CT and MRI showed comparable
performance for distinguishing XGC from GB cancer using specific imaging
findings.
Author Disclosures:
B. Choi: Consultant; Research Consultant, Samsung Electronics Co. Ltd.
B-0009 11:42
Dual-energy CT of the pancreas: improved carcinoma-to-pancreas
contrast with a novel mono-energetic reconstruction algorithm
R.W. Bauer, F. Fessler, J.M. Kerl, B. Schulz, C. Frellesen, T.J. Vogl,
J.L. Wichmann; Frankfurt a. Main/DE (
[email protected])
Purpose: To evaluate a novel mono-energetic reconstruction algorithm with
improved noise reduction for dual-energy CT of the pancreas.
Methods
and Materials: 35 patients with suspected pancreatic carcinoma
underwent dual-source dual-energy CT with arterial phase. Images were
reconstructed as virtual 120 kV series (M_0.6) and with the standard mono-
energetic application at 40 keV and 55 keV. Additional image series were
reconstructed with the novel "mono-energetic plus" application promising
improved noise reduction (40+ and 55+). Image quality was compared
between all series with respect to noise, pancreas signal, SNR and pancreas-
to-lesion contrast.
Results
12 carcinomas were detected. Compared to the standard M_0.6
series signal of healthy pancreas tissue was significantly higher for all mono-
energetic reconstructed images. With the standard mono-energetic algorithm
noise increased with lower energies (55: 20 HU; 40: 41 HU), while the novel
algorithm was able to keep the noise at a constantly low level (7 HU for 55+
and 40+) with no significant differences to the M_0.6 series (9 HU). SNR of the
pancreas was significantly superior in the 40+ and 55+ than in the 40 and 55
standard series (35.5 and 20 vs. 7 and 8) and outperformed the M_0.6 series
(9.5). Likewise, pancreas-to-lesion contrast was highest in the 40+ series (12)
and thus significantly higher than in any of the other series (M_0.6: 2; 40: 1; 50:
2; 55+: 5).
Conclusion
A novel algorithm for mono-energetic reconstructed dual-energy
CT data can significantly improve image quality in the diagnosis of pancreatic
carcinoma.
S138
B A C D E F G
Thursday
B-0010 11:51
Imaging findings of ischemic cholecystitis following transarterial
chemoembolisation prior to liver transplantation for hepatocarcinoma
E. Danse, X. Pavard, J. Lerut, P. Goffette, P. Trefois, L. Annet, C. Dragean,
N. Michoux; Brussels/BE (
[email protected])
Purpose: To identify imaging features helping diagnose ischemic cholecystitis
(IC) consecutive to transarterial chemoembolisation (TACE).
Methods
and Materials: A retrospective review of TACE procedures prior to
treat hepatocarcinoma was performed including 46 patients (35 transplanted, 2
died, 9 on the waiting list for liver transplantation). Post TACE US/MRI-derived
features were correlated to the final diagnosis based on pathologic analysis
(35) or biological and clinical follow-up (11). Following were considered at
US/MRI: wall thickening (3 mm), gallbladder distension (short axis > 4 cm),
pericholecystic fluid and infiltration, striated wall, wall irregularities, at MRI: T1
hypersignal of the gallbladder wall on unenhanced sequence, T1
hyperattenuation of the gallbladder wall and/or of the adjacent liver
parenchyma on Gd-enhanced sequence, at Sonography: Murphy sign,
increased colour Doppler signal of the gallbladder wall. Scott's pi was used to
assess inter-modality agreement. A logistic regression was performed to
identify imaging features which contribute significantly to the prediction of IC.
Results
IC was diagnosed in 12 patients. The most common features
(frequency/Se/Sp) were wall thickening (91%/83%/91%), striated wall
(82%/74%/96%), and wall irregularities (73%/75%/95%). Spontaneus
hypersignal T1 signal of the gallbladder wall has a sensitivity and specificity of
66 % and 100%, respectively. These features were significantly more present
in positive patients (p < 0.005). Within a logistic model, they predict IC with a
good performance level (Youden index=0.91). Imaging-Pathology agreement
was good (pi=0.8) as well as US-MRI agreement (0.6< pi< 0.8).
Conclusion
A model based on three imaging features may allow predicting
acute ischemic cholecystitis with US or MRI.
10:30 - 12:00 Room C
Cardiac
SS 103
Acute chest pain, prognosis and risk
stratification
Moderators:
M. Gardarsdottir; Reykjavik/IS
S. Leschka; St. Gallen/CH
B-0011 10:30
Challenges in the use of a computed tomography imaging-based
cardiovascular risk assessment tool in routine practice
P. Jairam, T. Blokhuis, H.M. Verkooijen, P.A. de Jong, F. Rutten, L. Leenen,
W.P.T.M. Mali, Y. van der Graaf; Utrecht/NL (
[email protected])
Purpose: Incorporation of a CT-based cardiovascular disease (CVD) risk
score into clinical practice may complement standard conventional risk factors-
based strategies in cardiovascular risk screening. The current study evaluates
the potential barriers to the introduction of the CT-based CVD risk score in
daily practice.
Methods
and Materials: We conducted a pilot study among referring
physicians, radiologists and general practitioners (GP) involved in the
application of the CT based CVD risk score. Hundred traumatology patients
who underwent chest CT scanning in the UMC Utrecht were included.
Adherence percentages of the referring physicians and radiologists to the
regular and correct application of the CT based CVD risk score were assessed.
Additionally, the GPs attitudes towards follow-up of the CT based CVD risk
score result in primary prevention setting were evaluated.
Results
Among the clinicians referring the patient for CT scanning 18%
specifically requested for CVD risk assessment and 42% conveyed the CVD
risk to the GP. Only 32% of the radiologists assessed the CVD risk score
although it was specifically requested. Among the GPs 14% were negative
towards follow-up of the CVD risk score result in primary prevention setting.
Conclusion
In current daily practice, there are certain barriers that need to be
reduced to make the implementation of the routine use of the CT based CVD
risk score realizable. Main deficiencies identified are: unfamiliarity and incorrect
application of the CT-based CVD risk score, unawareness about the
significance of CVD risk prevention in general, financial- and time constraints.
B-0012 10:39
Prognostic significance of cardiac magnetic resonance Imaging in
patients with acute chest pain, elevated cardiac enzymes and a negative
coronary angiogram
T. Emrich, M. Kros, N. Abegunewardene, T. Münzel, C. Düber, K.-F. Kreitner;
Mainz/DE (
[email protected])
Purpose: To assess the prognostic value of cardiac MRI in patients with acute
chest pain, elevated cardiac enzymes and a negative coronary angiogram.
Methods
and Materials: In a 51 months period, 152 patients allocated by the
chest pain unit could be included in this study. Based on consensus reading of
all available clinical, laboratory and imaging data, there were 54 patients with
myocarditis, 27 patients with dilative ca rdiomyopathy, 21 patients with ischemic
cardiomyopathy, 15 patients with Tako-Tsubo cardiomyopathy and 17 patients
with a hypertensive cardiomyopathy. Furthermore we detected miscellaneous
other cardiac diagnoses (e.g. tachymyopathy, hypertrophic cardiomyopathy or
non-compaction cardiomyopathy n = 18). CMRI enabled correct assignment of
diagnosis in 90 % of cases. All patients could be followed up either by
telephone call or by patients' medical record after a mean of 50 months.
Primary endpoints were the occurrence of MACE (death, stroke, heart failure,
recurrent hospitalisation), secondary endpoints were the initiation of an
interventional respectively operative procedure or a continuous medical
therapy.
Results
Primary and secondary endpoints were reached most often in
patients with dilative cardiomyopathy, non-compaction cardiomyopathy and
tachymyopathy compared with all other diagnoses (p < 0.01), followed by
patients with hypertensive heart disease. The most favorable prognosis had
patients with Tako-Tsubo cardiomyopathy and patients with myocarditis.
Conclusion
CMRI helps establishing the final diagnosis in patients with acute
chest pain, elevated cardiac enzymes and a negative coronary angiogram in
the vast majority of cases and is of prognostic significance.
B-0013 10:48
Usefulness of CT angiography in low and moderate cardiovascular risk
patients with chest pain admitted to emergency room in multimodal
hospital
P.T. Klimeczek, J. Jagas, W. Witkiewicz; Wroclaw/PL
(
[email protected])
Purpose: The purpose of the study was to evaluate usefulness and safety
angio-CT in patients admitted to the ER with chest pain. Angio-CT was
gatekeeper to invasive procedures or non-invasive treatment.
Methods
and Materials: The prospective study covered 206 patients (mean
age 66 +/- 15, 109 F) admitted to the ER with chest pain and low to
intermediate cardiovascular risk. Patients were randomly assembled into two
subgroups. Treatment in Group A comprised of risk assessment and invasive
diagnostics, if necessary (102 pts, 55 F). Group B (104 pts, 52 F) patients
underwent contrast CT-angiography with prospective ECG gating (triple rule
out protocol) appended to the routine proceeding.
Results
In group A, 104 DSCT were performed and subsequently 30 patients
underwent coronary angiography (24 PCI, 4 CABG, 2 muscular bridges). In 74
cases, coronary stenosis as a cause of chest pain was excluded and patients
after short clinical observation were discharged or relegated to another
specialist (due to additional findings). Among 1,096 coronary segments, 92
(8.3%) were nonevaluable (mostly distal parts and small branches). Effective
radiation dose was for DSCT 10.4+/4.2 mSv. In the period of follow-up (mean
342+/-65 days), there were no hospitalisations due to bias in coronary
assessment in CT. DSCT as a diagnostic procedure demonstrated
discriminative value: area under ROC curve 0.977 for 0.95 confidence interval
and p<0.002. Sensivity 100%, Specificity 95.4%, PPV 89% and NPV 100%. In
group B: In 101 patients conventional coronary angiography and next 35 PCI
and 6 CABG were performed. In 60 cases CCA was negative.
Conclusion
DSCT helps to avoid unnecessary invasive procedures due to
coronary stenosis exclusion.
B-0014 10:57
Coronary risk stratification in asymptomatic population: impact of
cardiac CT
D. Caruso, S. Ferretti, D. Bellini, M. Spallone, G. Carlino, M. Rengo, A. Laghi;
Rome/IT (
[email protected])
Purpose: To demonstrate the impact of cardiac CT (CTCA) in the stratification
of cardiovascular risk in a population of asymptomatic patient with classic risk
factors for coronary artery disease (CAD) compared to the systematic coronary
risk evaluation (SCORE).
Methods
and Materials: We included 123 asymptomatic patients (97 men/ 26
women; age 51.3 ±7.2) who underwent CTCA after clinical evaluation during
which a risk for cardiovascular events in 10 years with the SCORE was
calculated. Calcium score was also evaluated. Three possible outcomes were
hypotised: patient with no CAD, patients with non-significant coronary stenosis,
S139
B A C D E F G
Thursday
and patients with significant coronary stenosis. On the basis of CACA results,
we developed a simulation model to evaluate the effect on patient
management.
Results
The pretest risk of cardiovascular events in the asymptomatic
population was 1.06%. The average value of calcium score was
56.48 ± 176.61 (moderate risk). We found 17 patients with significant coronary
stenosis who underwent coronary revascularisation. Over 50 patients with non-
significant coronary stenosis began a medical treatment with statins. The
average risk for cardiovascular events was 0.42 ± 0.66 after a cardiac CT
exam.
Conclusion
We demonstrated an hypothetical reduction of the average risk
for cardiovascular events using cardiac CT.
B-0015 11:06
The incremental prognostic value of dual-source computed tomography
coronary angiography in subjects with suspected or known coronary
artery disease
T. Miszalski-Jamka, B. Kedzierski, T. Kuniej, A. Stoinska, P. Gac, R. Poreba,
P. Jazwiec; Wroclaw/PL
Purpose: To assess incremental prognostic value of double-source computed
tomography (DSCT) coronary angiography over clinical data in patients with
known or suspected coronary artery disease.
Methods
and Materials: Clinical and DSCT data were analysed in 311
consecutive patients who were scheduled for DSCT coronary angiography.
DSCT angiograms were assessed for presence, luminal stenosis severity,
location, and type (non-calcified, mixed or calcified) of coronary atherosclerotic
plaques. 311 patients (164 males, mean age 54.0 ±8.1 years) were followed-up
for 18.3 ±4.0 months. Cardiac events (cardiac death, non-fatal myocardial
infarction (MI), revascularisation and cardiac hospitalisations were related to
clinical and DSCT data. Cox proportional-hazards model was applied in
stepwise forward fashion to identify predictors of outcome.
Results
Coronary plaques were found in 197 patients. Cardiac events
occurred in 25 patients (2 cardiac deaths, 3 MI, 8 revascularisations, 15
hospitalisations). Independent predictors of subsequent events were diabetes
mellitus, prior MI, coronary plaque, and 50% left main stenosis. In sequential
Cox models predictive power of clinical model was strengthened by DSCT data
(p < 0.05).
Conclusion
DSCT coronary angiography enhances prognostic value of
clinical data in patients with suspected or known coronary artery disease.
B-0016 11:15
Anatomic vs functional testing in patients with chronic chest pain
syndrome: a cost-effectiveness analysis
A. Goehler1, T. Mayrhofer2, A. Pursnani2, S. Huber1, J. Bayley2, J. Nolte2,
G. Gazelle2, B. Chow3, U. Hoffmann2; 1New Haven, CT/US, 2Boston, MA/US,
3Ottawa, CT/CA (
[email protected])
Purpose: Improvements in Coronary CT angiography (CTA) have led to
debate about whether anatomic or functional testing is more cost-effective in
patients with suspected obstructive coronary artery disease (CAD). We
simulated clinical outcomes and costs of CTA and functional testing.
Methods
and Materials: We developed a Markov model to simulate CAD
progression and mortality in 3,719 patients from the Ottawa Cardiac CT
Registry. We compared no testing (SOC) to CTA (CTA), stress-EKG/stress-
echo/SPECT (in 20%, 50%, and 30% of the cases) (FT), FT followed by CTA
(FT-CTA) and CTA followed by FT (CTA-FT).
Results
In our population (age 58 years, 52% male, 68% moderate NCEP,
9% high NCEP) the prevalence of CAD was 14% obstructive (54% non-
obstructive). FT correctly identified 11% (13%) at costs of $848/patient; CTA
12% (52%), CTA-FT 10% (52%), FT-CTA 10% (12%) at $892, $762, and $681
per patient, respectively. The model predicted an average remaining life
expectancy of 16.33 quality adjusted life years (QALY) for SOC and 16.44,
16.46, 16.44 and 16.44 QALYs for FT, CTA, CTA-FT, and FT-CTA,
respectively. This resulted in incremental cost-effectiveness ratios (ICER) of
$19,500/QALY for FT-CTA compared to SOC, and $24,300/QALY for CTA vs.
FT-CTA; FT and CTA-FT were both dominated. When including treatment for
non-obstructive CAD, life expectancy increased by 0 to 0.6 QALYS depending
on the percentage of non-obstructive CAD diagnosed; CTA cost-effectiveness
improved to $5,000/QALY; the other strategies were dominated.
Conclusion
Preliminary analyses indicate th at CTA is cost-effective for initial
evaluation of patients with chronic chest pain.
B-0017 11:24
Prognostic value of cardiac CT in a asymptomatic population: 2-years
follow-up
D. Caruso, M.M. Maceroni, F. Vecchietti, D. Bellini, L. Bertana, S. Ferretti,
M. Rengo, A. Laghi; Latina/IT (
[email protected])
Purpose: To evaluate the prognostic value of cardiac CT in a population of
symptomatic patients with intermediate risk of coronary heart disease.
Methods
and Materials: One hundred twenty-three asymptomatic patients
with intermediate cardiovascular risk underwent CT coronary angiography
(CTCA). Calcium score was also evaluated. Patients were classified in three
groups: patients with no CAD, patients with non-significant coronary stenosis,
patients with significant coronary stenosis according to CTCA results.
Development of major cardiac events (cardiac death, non-fatal myocardial
infarction, and unstable angina requiring hospitalisation, coronary
revascularisations) or worsening of clinical conditions was evaluated for a 2-
year period.
Results
None of the patients included in the "no CAD" group (51%) developed
major cardiac events in 2 years. All patients (13.8%) with significant coronary
stenoses underwent revascularisation within 6 months. Half of the patients with
non-significant coronary stenoses (17% of the initial population) developed
symptoms (70% stable angina, 30% unstable angina). The overall rate of major
cardiac events (revascularuisation and unstable angina) was 23.8%.
Conclusion
Multislice CT showed a high prognostic value in patients with
intermediate risk for coronary heart disease. In particular, the prognosis of
patients with negative cardiac CT for coronary heart disease was excellent at
2-years follow-up.
B-0018 11:33
Residents' performance in the interpretation of on-call "triple-rule-out"
CT studies in patients with acute chest pain
A.J. Lewis, K.G. Garrett, U.J. Schoepf, J.R. Silverman, A.W. Krazinski,
L. Geyer, P. Suranyi, F.G. Meinel, P. Costello; Charleston, SC/US
(
[email protected])
Purpose: To evaluate the agreement between preliminary Radiology resident
and final subspecialty attending interpretation of on-call, emergency "Triple-
Rule-Out" (TRO) CT studies in patients with acute chest pain.
Methods
and Materials: The study was IRB-approved and HIPAA compliant.
Data from 617 on-call TRO studies were analysed. Dedicated software enables
subspecialty attendings to grade discrepancies in interpretations between
preliminary trainee reports and their final interpretation as "unlikely to be
significant" (minor discrepancies) or " likely to be significant" for patient
management (major discrepancies). The frequency of minor, major and all
discrepancies was compared with 609 emergent non-ECG-synchronised chest
CT studies using Pearson's 1
2 test.
Results
The total number of discrepancies was significantly higher in the TRO
group (11.2%) compared to the control group (6.7%, p=0.008). Minor
discrepancies occurred more often in the TRO group (9.1% vs. 3.9%,
p < 0.001), but there was no difference in the frequency of major discrepancies
(2.1% vs. 2.8%, p=0.55). Minor discrepancies in the TRO group most
commonly resulted from missed extrathoracic findings with missed liver lesions
being the most frequent. Major discrepancies mostly encompassed cardiac
and extracardiac vascular findings.
Conclusion
On-call resident interpretation of TRO CT studies in patients with
acute chest pain is congruent with final subspecialty attending interpretation in
the overwhelming majority of cases. The rate of discrepancies likely to affect
patient management in this domain is not different from emergent non-ECG-
synchronised chest CT.
Author Disclosures:
U.J. Schoepf: Consultant; Bayer, Bracco, GE, and Siemens. S140
B A C D E F G
Thursday
B-0019 11:42
Assessment of coronary plaque by coronary CT angiography in patients
with acute coronary syndrome non-ST segment elevation
S. Gaman, N. Barysheva, M. Shabanova, I. Merculova, M. Shariya;
Moscow/RU (
[email protected])
Purpose: To evaluate plaque characteristics of culprit lesion in patients with
acute coronary syndrome (ACS) non-ST segment elevation.
Methods
and Materials: 25 patients with ACS non-ST segment elevation
underwent coronary CT angiography (64-MSCT Aquilion, Toshiba, Japan; 100-
120 ml intravenously contrast agent Ultravist 370 ,Bayer, Germany) within 24
hours after onset. The plaques were divided in 4 groups, namely, soft (Group
1), mixed (Group 2), calcified (Group 3), obstructive (Group 4). The level was
between 360-380 HU, the window between 1010-1030 HU. We estimated 5
criteria of culprit lesion: X-ray minimum density, length of plaque, spotty
calcification (diameter < 3 mm), remodeling index, rough contour, the ring-like
enhancement.
Results
We evaluated 25 coronary segments. Soft plaques were in 28%
(n=7). Mixed plaques were in 52% (n=13). Calcified plaques were in 8% (n=2).
Obstructive plaques (with thrombotic component) were in 12% (n=3). Mean
density of plaque in Group 1 was 34.7+10.5 (18-60) HU, in Group 2 was
51.2+24.2 (2-105) HU. Spotty calcification was in 57% (n=4) in Group 1. Rough
contour was identified in all plaques. Mean length of plaques was
16.86+6.94 mm. Positive remodeling was in 88% (n=22). Mean remodeling
index was 1.28+0.13. The ring-like enhancement was in 24% (n=6).
Conclusion
Coronary CT angiography allows detect unstable plaque,
subsequently resulting in ACS.
B-0020 11:51
Right-to-left ventricle ratios on pulmonary CTA in patients with acute
pulmonary embolism: correlation of volumetric ratio, embolus burden
and adverse outcome
B. Mensel, M. Holzinger, J.-P. Kühn, N. Hosten;
Greifswald/DE (
[email protected])
Purpose: The right-to-left ventricle ratio (RV/LV) is an important predictor of
right heart dysfunction in patients with acute pulmonary embolism (APE). We
compared the correlation of volumetric RV/LV, embolus burden expressed by
Mastora score and adverse outcome (AO) of APE with diametrically and
planimetrically determined RV/LV on pulmonary CTA.
Methods
and Materials: CTAs of 97 patients (median age, 63.5 years) were
analysed. For each patient, Mastora scoring was applied, the RV/LV was
determined by semiautomated volumetry (vol), diametry (diam) in axial and 4-
chamber views (4CH) and planimetry (plan) in axial and 4CH views. The time
for ratio measurements was taken.
Results
Correlation coefficients (CC) for RV/LV
vol vs. RV/LV plan4ch were
r=0.678 (P < 0.001), vs. RV/LV plan: r=0.629 (P < 0.001), vs. RV/LV diam4CH:
r=0.580 (P < 0.001) and vs. RV/LV diam: r=0.577 (P < 0.001). CCs for Mastora
scores and RV/LV vol were r=0.663 (P < 0.001), RV/LV plan: r=0.645 (P < 0.001),
RV/LVplan: r=0.606 (P < 0.001), RV/LV diam: r=0.574 (P < 0.001) and
RV/LVdiam4CH: r=0.566 (P < 0.001). The median time needed for determination
of RV/LV vol, RV/LV plan4CH, RV/LV diam4CH, RV/LV plan and RV/LV diam were
16:48 min, 2:11 min, 1:26 min, 57 sec and 25 sec (P < 0.05). ROC analysis for
evaluation of AO revealed an AUC for RV/LV plan4CH of 0.731 (P < 0.003) and
0.700 (P < 0.01) for RV/LVplan. AUC for RV/LVvol was 0.786 (P < 0.001).
Conclusion
Determination of the RV/LV by planimetry is fast and better
correlates with volumetry and the embolus burden than diametry. It is
comparable to volumetry in predicting AO.
10:30 - 12:00 Room D
Chest
SS 104
Lung cancer screening and pulmonary
nodule evaluation
Moderators:
M. Regier; Hamburg/DE
E.J. Stern; Seattle, WA/US
B-0021 10:30
Tobacco smoking and screen-detected lung cancer: does it matter
beyond 30 pack-years?
R. Aktay, P. Mazzone, T.E. Love; Cleveland, OH/US (
[email protected])
Purpose: To investigate whether smoking pack-years among high-risk
individuals incrementally improves prediction of screen-detected lung cancer.
Methods
and Materials: National Lung Screening Trial (NLST) participants
(n=53,452), each with smoking history of 30 pack-years were stratified by
pack-years into three groups ( 60 and 42 identifying high and low;
mean±SD=83±23 and 37 ±4 respectively). For our analytic sample, we
randomly selected 6,000 individuals from the high (2,911) and low (3,089)
strata. We then estimated the propensity (PS) for high-smoker (exposure)
using multivariate logistic regressi on and 48 covariates, including socio-
demographics, occupational exposure, smoking status (former/current), family
history, and medical and extra-pulmonary cancer history. An optimal pairwise
propensity match produced 1,493 pairs of low- and high-smoker individuals. In
the matched sample, we estimated the association between high (vs. low-)
smoking and confirmed lung cancer (outcome), adjusting for PS and covariates
still imbalanced after matching, then compared these results to a model built
for all 6,000 individuals.
Results
High-smokers were older (62 vs. 60 years), and had younger
smoking-onset age (16 vs. 18) than low-smokers. In our matched sample,
logistic regression estimated an odds ratio (OR) of 2.0 (95% CI:1.2 - 3.3;
p=0.008) for confirmed lung cancer, compared to 2.2 (CI:1.6 - 3.1; p < 0.0001)
in the pre-match sample.
Conclusion
In NLST, lung cancer detection is significantly higher (OR=2.0) in
smokers with history of 60 pack-years as compared to 42 pack-years, even
after extensive covariate adjustment. Further analysis might suggest a new
threshold for pack-years as a screening selection criterion to reduce false-
positives and cost.
B-0022 10:39
Overruling of screen test results in a CT lung cancer screening trial:
value of radiologists' expertise
M.A. Heuvelmans
1, R. Vliegenthart1, X. Xie1, P.A. De Jong2, W. P.T.M. Mali2,
M. Oudkerk1; 1Groningen/NL, 2Utrecht/NL (
[email protected])
Purpose: To investigate the impact of radiologists' expertise on test result
decisions made in a CT lung cancer screening trial.
Methods
and Materials: In the Dutch-Belgian randomised lung cancer
screening trial (NELSON), the baseline screen result was based on the lung
nodule with largest volume. According to the protocol, nodule volume 500 mm3 led to a negative, indeterminate and positive
screen result, respectively. However, the NELSON protocol allowed
radiologists to adjust the screen result. All participants in whom the baseline
screen result was based on a solid nodule were included. Baseline nodule
volume and screen result according to protocol were compared to the final
screen result. Nodules were followed for up to 6.8years.
Results
In 3269 participants (2759 male, median age 58.0 years), the
baseline result was based on a solid nodule. In 189 participants (5.8%), the
initial result for the nodule was adjusted by the radiologist. Median follow-up
time of these nodules was 5.5years. The screen result was adjusted from
positive or indeterminate to negative in two and 118 participants, respectively.
None of these nodules turned out malignant. The result was adjusted from
negative or positive to indeterminate in one and 64 participants, respectively.
Lung cancer was detected in two (3.1%) nodules with volume > 500 mm
3 four
years later. In four participants the screen result was adjusted from
indeterminate to positive; two nodules were malignant (50%).
Conclusion
In a baseline lung cancer screening study, the readers adjusted
the screen result in 5.8%. Radiologists' expertise can reduce false-positive and
false-negative screen results.
S141
B A C D E F G
Thursday
B-0023 10:48
Comparison of diameter and volume measurements for the estimation of
nodule size for lung nodules detected in a CT lung cancer screening trial
M.A. Heuvelmans1, R. Vliegenthart1, N. Horeweg2, P.M.A. Van Ooijen1, W.
P.T.M. Mali3, H.J. De Koning2, M. Oudkerk1; 1Groningen/NL, 2Rotterdam/NL,
3Utrecht/NL (
[email protected])
Purpose: To compare congruity of estimation of lung nodule size in a lung
cancer screening trial by calculating volume based on maximal and mean
transversal diameter measurements, and measurements from semi-automated
volumetric software.
Methods
and Materials: The diameter and volume measurements of 7,914
solid pulmonary nodules detected in 3,165 participants from the Dutch-Belgian
randomised lung cancer screening trial (Dutch acronym: NELSON) were
evaluated. CT-scans were performed in low-dose setting. Nodule volumes
were obtained semi-automatically in the LungCARE software, and were
compared to volumes based on the maximal transverse diameter ( D) and the
mean transversal diameter in x-y direction, without taking into account the
diameter standard deviation, and assuming a spherical shape of the nodule
(formula: Volume=(1/6)*pi*D3).
Results
Semi-automated software yielded a median nodule volume of
37.5 mm3 (Interquartile Range (IQR): 23.8-67.7 mm 3). The median estimated
nodule volume using maximal and mean transversal diameter, was 61.6 mm 3
(IQR: 38.8-130.9 mm3), and 47.7 mm 3 (IQR: 28.7-91.9 mm3), respectively. The
use of maximal diameter and mean diameter to estimate nodule size
overestimated nodule volume by 55.6% (median, IQR: 25.3-96.1%) and 23.8%
(median, IQR: 1.6-51.5%), respectively, compared to semi-automated
volumetry. This overestimation would res ult in an increase of positive test
Results
in a lung cancer screening setting based on diameter measurements.
Conclusion
Estimation of nodule volume based on maximal transversal
diameter measurements overestimates nodule size compared to semi-
automated volumetry. We recommend using nodule volume instead of
diameter to assess lung cancer probability and determine thresholds for
screening results.
B-0024 10:57
Ground glass nodules: CT-epidemiological analysis of growth patterns
M. Silva1, F. Centra1, D. Colombi1, C. Rossi1, N. Sverzellati1, A.A. Bankier2;
1Parma/IT, 2Boston, MA/US (
[email protected])
Purpose: To quantify growth patterns of solitary pure ground glass nodules
and to relate these pattern to epidemiological factors.
Methods
and Materials: Between 2008 and 2011, 95 patients were diagnosed
on CT with solitary pure ground glass nodule (pGGN) at our hospital. CT
features of pGGNs were evaluated at an initial and a follow-up CT. pGGNs
were divided into "persisting" or "resol ved". Persisting nodules were further
classified according to potential changes in total or solid component diameter
into "decreased", "unchanged", and "increased". Clinical and demographic data
were recorded. Association of data with morphological pGGNs characteristics
were tested with Kruskall-Wallis test and logistic regression.
Results
After a median follow-up of 16 months, 19/95 (20%) pGGNs resolved
and 76/95 (80%) persisted. Of the persisting pGGNs, 51/76 (67.1%) were
unchanged, 18/76 (23.7%) increased in size, and 7/76 (9.2%) decreased.
Growth was more likely with age 67 years and a diameter 10 mm (OR
4.636; p = 0.016). No significant relation was found between pGGNs growth
and gender, history of cancer, or pGGN location. pGGN resolution was more
likely with age < 67 (OR 3.28; p = 0.04). No difference in diameter was found
between resolved and persisting pGGNs (p = 0.21).
Conclusion
As expected, persisting larger pGGNs were more likely to grow
than small pGGNs. However, solitary pGGNs were more likely to grow in older
than in younger patients. This observation could help to tailor future follow-up
recommendations for pGGNs with regard to the seemingly paradoxical
influence of patient age.
B-0025 11:06
Evaluation of subcentimeter ground-glass nodule at very low dose CT:
impact of different levels of iterative reconstruction
K. Parekh, A.R. Seyal, R. Agrawal, T.H. Grant, A. Goodwin, V. Yaghmai;
Chicago, IL/US (
[email protected])
Purpose: The purpose of our study was to determine the effect of different
levels of iterative reconstruction on the evaluation of ground-glass nodule at
significantly reduced radiation doses.
Methods
and Materials: An anthropomorphic chest phantom containing a
sub-centimeter ground glass lung nodule was scanned at 80, 100 and 120 kV
with 10, 20, 40, 75 and 110 mA. Images were reconstructed with filtered back
projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE)
algorithm using two different strengths of iterative reconstruction (3 and 5).
Forty-five image sets were randomised and shown to two chest radiologists
independently. For each image, both radiologists measured the largest lesion
diameter and evaluated lesion conspicuit y on a five-point scale. A score of 3
was considered acceptable for lesion conspicuity. Data was analysed with
paired t-test, Friedman test and Wilcoxon signed rank test. Kappa statistics
were used for inter-reader agreement.
Results
The lowest radiation dose parameters with an acceptable score were
80 kVp/10 mAs (0.098mSv) for IR-5 and 100 kVp/10 mAs (0.224 mSv) for FBP
and IR-3. Mean lesion diameter was comparable between FBP, IR-3 and IR-5
for effective doses above and below 1 mSv (p > 0.05). The diameter
measurements were similar for both radiologists below 1 mSv for each
reconstruction algorithm (p > 0.05). Inter-reader agreement for subjective
assessment of lesion conspicuity was fair (k=0.259). Image noise, CNR and
SNR were significantly different between the three reconstruction algorithms
(p < 0.001).
Conclusion
Increasing the strength of iterative reconstruction may allow
greater dose reduction without compromising size and conspicuity of ground
glass nodule.
Author Disclosures:
K. Parekh: Research/Grant Support; Educational Grant Support from Siemens
Healthcare. A.R. Seyal: Research/Grant Support; Educational Grant Support
from Siemens Healthcare.
B-0026 11:15
Usefulness of alpha blending of maximum intensity projections or ray
sums with segmented pulmonary nodules and vasculature for the
evaluation of small nodules or ground glass opacity lesions
Y. Nakano
1, K. Maeda1, S. Kitahara1, T. Toyama1, T. Nakaguchi1,
M. Kuwabara1, T. Kubo2; 1Kusatsu/JP, 2Kyoto/JP (
[email protected])
Purpose: There are many small lung nodules and ground glass opacity (GGO)
lesions depicted on computed tomography (CT) scans that are difficult to
diagnose using chest computed radiograph y (CR) or a cine display of serial
chest radiographs obtained with a flat-panel detector (FPD-SR). Alpha
blending was used to display an alpha bitmap, which is a bitmap that has
transparent or semi-transparent pixels. We aimed to use the alpha-blended
images obtained from CT to support the diagnosis of pulmonary nodules.
Methods
and Materials: Using alpha blending, thi ck slab, coronal maximum
intensity projection (MIP), or ray sum images were overlaid with the segmented
pulmonary nodule and vasculature using various transparencies. In the
comparison of the detectability of pulmonary nodules on FPD-SR and chest
CR, 18 patients with 20 nodules were included that were confirmed by CT and
were difficult to diagnose with FPD-SR and CR. For each patient, FPD-SR, CR,
and CT with and without alpha-blended images were evaluated independently
by four radiologists for a subjective image assessment of the diagnostic quality.
Results
Alpha-blended images preserved the depth relationship between the
nodule and the rib or pulmonary vasculature and prevented these small
structures from being obscured. Subjective image analysis illustrated a
significant improvement when employing alpha blending for clinically relevant
criteria such as diagnostic confidence.
Conclusion
Alpha blending of thick slab MIP or ray sum images with
segmented pulmonary nodules and vasculature provides useful information
concerning the exact localisation of small lung nodules, including GGO, on
FPD-SR and CR.
Author Disclosures:
Y. Nakano: Grant Recipient; Canon Inc.
B-0027 11:24
Pulmonary adenocarcinoma presenting as part-solid ground glass
nodule: is measuring solid component only appropriate in current
staging system?
E. Hwang, C. Park, S. Lee, J. Goo, Y. Ryu; Seoul/KR
(
[email protected])
Purpose: To find out appropriate measurement for pulmonary
adenocarcinoma presenting with part-solid ground glass nodule (psGGN), by
comparing disease-free survival (DFS) and overall survival (OS) with
adenocarcinoma appearing as solid nodule (SN).
Methods
and Materials: Our study included 501 patients (304 SN and 197
psGGN) who underwent curative surgery for pathologic stage I
adenocarcinoma between 2002 and 2011. Maximal diameters of lesions were
measured on axial preoperative CT images. For psGGN, maximal diameters of
whole lesions and solid components were separately measured on axial thin
slice (2 mm) images. DFS and OS were calculated from the date of surgery.
To find out significant factor for DFS and OS, Cox proportional hazard
analyses were performed. Afterwards, interaction term between solid
component size and nodule type was inserted to compare prognoses of SN
and psGGN with same size of solid component.
Results
The size of solid component was the only significant factor for DFS
and OS in multivariate Cox analyses in psGGN group only (Hazard ratios 4.68
and 3.46 for DFS and OS, respectively, for 1 cm increase in size) and in whole
patients group (Hazard ratios 1.81 and 1.73 for DFS and OS, respectively).
Comparing prognoses of psGGN and SN based on Cox-regression model with
S142
B A C D E F G
Thursday
interaction term, psGGN showed better DFS and OS when solid components
were 2 cm, but SN showed better prognoses when solid components were
larger.
Conclusion
Measuring solid component only might be an appropriate method
to evaluate adenocarcinoma presenting as psGGN. However, psGGN and SN
showed different prognoses in same size of solid component
B-0028 11:33
Differentiation of invasive pulmonary adenocarcinomas presenting as
pure ground-glass nodules from their preinvasive lesions by using
computerised image feature analysis from multi-detector computerised
tomography images
I. Hwang, C. Park, S. Park, S. Lee, J. Goo, H.-J. Lee; Seoul/KR
(
[email protected])
Purpose: To evaluate the diagnostic feasibility of three-dimensional
computerised image feature analysis of multi-detector computerised
tomography (MDCT) images to aid differentiation of invasive pulmonary
adenocarcinomas (IPAs) presenting as a pure ground-glass nodules (PGGNs)
from their preinvasive lesions.
Methods
and Materials: This retrospective study was finally included a total of
38 patients with 40 pulmonary nodules presenting as PGGN on thin-section
(1 mm section thickness) MDCT without contrast enhancement from January
2005 to February 2013. All of these nodules were pathologically confirmed and
divided into IPA group (n=9) and preinvasive group including atypical
adenomatous hyperplasia (n=13) and adenocarcinoma in situ (n=18). Manual
segmentation was performed in each PGGN on every slice of CT images and
computerised image features were quantitatively extracted using in-house
developed software. To identifying image features between IPAs and their
preinvasive lesions, independent t-test and multivariate logistic regression
analysis were performed.
Results
Between IPA group and preinvasive lesion group, patient's age (60.3
vs. 57.2years, respectively, P=.340) and lesion size (14.6 vs. 11.3 mm,
respectively, P=.441) were not significantly different. By independent t-test of
image features revealed that mean attenuation number (P=.043), standard
deviation of attenuation number (P=.016), 95percentile of attenuation number
(P=.008), entropy (P=.008) and gray-scale co-occurrence matrix contrast
(P=.036) were significantly different bet ween IPA and preinvasive lesion.
However, multivariate logistic regression analysis including those image
features revealed that entropy was the only differentiating variable (P=.020).
Sensitivity and specificity were 22.2% (2/9) and 90.3% (28/31), respectively.
Conclusion
We suggest that entropy are specific image feature and may be
helpful in differentiating IPAs presenting as PGGN from preinvasive lesion.
B-0029 11:42
Dynamic first-pass pulmonary perfusion area-detector CT for lung nodule
assessment: comparison of dose reduction capability between adaptive
iterative dose reduction using 3D processing and filter back projection
Y. Ohno
1, S. Seki1, M. Nishio1, H. Koyama1, T. Yoshikawa1, S. Matsumoto1,
Y. Fujisawa2, N. Sugihara2, K. Sugimura1; 1Kobe/JP, 2Otawara/JP
(
[email protected])
Purpose: To directly compare the capability for radiation dose reduction on
dynamic chest perfusion area-detector CT (ADCT) aiming lung and nodule
perfusion assessments between adaptive iterative dose reduction using 3D
processing (AIDR 3D) and filter back projection (FBP) methods.
Methods
and Materials: 36 consecutive patients with pulmonary nodules
underwent standard-dose perfusion ADCT (SDCT) using the following
parameters: 320×0.5 mm collimation, 80 kVp, 120 mA, and 0.5 sec gantry
rotation time. From SDCT raw data, low-dose perfusion ADCTs (LDCTs) at
80 mA, 60 mA and 40 mA were computationally simulated. Then, SDCT and
each LDCT were reconstructed by AIDR 3D and FBP methods. From each CT
data, perfusion map was computationally generated. Then, image noises of
lung parenchyma and nodule, lung and nodule perfusions were evaluated by
ROI measurements. To determine the utility of AIDR 3D for radiation dose
reduction, both image noises and perfusion parameters from all CT data were
statistically compared each other by using Tukey's HSD test. Correlations and
the limits of agreement on both perfusion parameters at each LDCT were
statistically evaluated.
Results
When applied AIDR 3D, image noises of LDCT at 80 mA and 60 mA
were significantly lower than those by FBP (p < 0.05). Lung and nodule
perfusions had significant and excellent correlations between SDCT and each
LDCT (p < 0.001). The limits of agreement on each LDCT applied AIDR 3D
were smaller than that applied FBP.
Conclusion
AIDR 3D method has better potential for radiation dose reduction
of chest perfusion ADCT than FBP method in routine clinical practice.
Author Disclosures:
Y. Ohno: Research/Grant Support; Toshiba Medical Systems Corporation,
Daiichi-Sankyo, Co. Ltd., Bayer Pharma. S. Seki: None. M. Nishio:
Research/Grant Support; Toshiba Medical SystemsCorporation. H. Koyama:
None. T. Yoshikawa: Research/Grant Support; Toshiba Medical Systems
Corporation.s. Matsumoto: Research/Grant Support; Toshiba Medical
Systems Corporation. Y. Fujisawa: Employee; Toshiba Medical Systems
Corporation. N. Sugihara: Employee; Toshiba Medical Systems Corporation.
K. Sugimura: Research/Grant Support; Daiichi-Sankyo Co. Ltd., Bayer
Pharma.
B-0030 11:51
Prognostic value of spirometry and pulmonary CT biomarkers for
cardiovascular events in a lung cancer screening setting
R.A.P. Takx1, R. Vliegenthart2, H.J. de Koning3, B. van Ginneken4,
W.P.T.M. Mali1, M. Oudkerk2, T. Leiner1, P.A. de Jong1; 1Utrecht/NL,
2Groningen/NL, 3Rotterdam/NL, 4Nijmegen/NL (
[email protected])
Purpose: To assess the prognostic value of spirometry and quantitative
pulmonary CT biomarkers for cardiovascular events.
Methods
and Materials: 3057 male lung cancer screening subject who
underwent spirometry and non-gated chest CT were analysed. Forced
expiratory volume in one second percent predicted (FEV1%predicted) and
FEV1 divided by forced vital capacity (FVC) were obtained. Coronary artery
calcium volume, pulmonary emphysema (Perc15) and bronchial wall thickness
(Pi10) were measured on the CT scans. The primary combined endpoint
included fatal and non-fatal cardiovascular events. The ability of spirometry
and pulmonary CT measures to predict events was evaluated by Cox
proportional hazards analysis. Next, net reclassification improvement (NRI) and
incremental C-indices were calculated.
Results
Median follow-up was 2.9 (25p-75p 2.7-3.3) years and during that
period 183 participants developed a cardiovascular event. Spirometry and
pulmonary CT biomarkers were associated with an increased risk of
cardiovascular events. Age, smoking status and pack-years adjusted hazard
ratios were 0.992 (95%-CI 0.985-0.999) for FEV1%predicted, 1.001 (95%-CI
0.987-1.015) for FEV1/FVC 1.014 (95%-CI 1.004-1.023) for perc15 per 10 HU
and 1.264 (95%-CI 1.019-1.567) for pi10 per 1 mm. Incremental C-index
(< 0.012) and NRI (0.22). In contrast, coronary artery calcium volume had an
adjusted hazard ratio of 1.046 (95%-CI 1.034-1.058) per 100 mm3, a
significant increase in C-index of 0.077 and an impressive NRI of 17.3%
(P < 0.0001).
Conclusion
Spirometry and pulmonary CT biomarkers were significantly
associated with cardiovascular events, but did not provide relevant
independent prognostic information for cardiovascular events in a male lung
cancer screening population.
Author Disclosures:
H.J. de Koning: Advisory Board; Roche Diagnostics. T. Leiner:
Research/Grant Support; Bracco Diagnostics. Speaker; Philips Healthcare,
Bayer Healthcare.
10:30 - 12:00 Board Room B
Emergency Radiology
SS 117
Impact of radiology on emergency
services
Moderators:
D. Nunez; New Haven, CT/US
F. Schwarz; Munich/DE
B-0031 10:30
How does arm positioning of polytraumatised patients in the initial CT
affect image quality and diagnostic accuracy?
J. Kahn, M. Maurer; Berlin/DE (
[email protected])
Purpose: To evaluate the influence of different arm positions on abdominal
image quality during initial whole-body CT (WBCT) in polytraumatised patients
and to assess the risk of missing potentially life-threatening injuries due to arm
artefacts.
Methods
and Materials: Between July 2011 and February 2013, WBCT scans
of 203 patients with arms in the abdominal area during initial WBCT were
analysed. Six different arms-down positions were defined. 203 patients with
elevated arms beside the head served as a control group. Two observers
jointly evaluated image quality of different organ regions using a 4-point-scale
system. Follow-up CT-examinations were analysed to identify findings missed
during initial WBCT due to reduced image quality.
S143
B A C D E F G
Thursday
Results
Image quality was most severely degraded in patients with arms
down alongside the torso, followed by patients with arms crossed in front of the
pelvic area and patients with arms crossed in front of the upper abdomen,
respectively. Positioning with one arm up resulted in significantly better image
quality than both arms down (p < 0.01). Overall, arms-up positioning showed
significantly better image quality than arms-down positions (p < 0.01). In one
case, liver haemorrhage missed in the initial WBCT because of arm artefacts,
was revealed by follow-up CT.
Conclusion
In WBCT arms-down positioning significantly degrades
abdominal image quality and artefacts might even conceal potentially life-
threatening injuries. If the patient's status does not allow elevation of both
arms, image quality can benefit from raising at least one arm. Otherwise, arms
should be placed in front of the upper abdomen instead of alongside the torso.
B-0032 10:39
Indication of whole-body multislice computed tomography in
polytraumatised children
F. Wolfschmidt, I. Platzer, S. Manger, T. Wurmb, T. Bley, W. Kenn;
Würzburg/DE (
[email protected])
Purpose: To retrospectively analyse the applicability of a triage protocol for the
indication of whole-body MSCT as well as epidemiologic data from children
with suspected polytrauma.
Methods
and Materials: 72 children (49 male, aged 1 to 14 years) admitted to
a Level 1 trauma center with suspected polytrauma during 2004 to 2009 were
enrolled. Whole-body MSCT (16-slice SIEMENS Somatom Sensation CT;
sliding gantry) was indicated as in adult patients if one triage criteria basing on
mechanism of injury, vital parameter and injury pattern was fulfilled. Data
analysis included under- and overtriage rates, Injury Severitiy Score (ISS),
mechanism of injury, injury pattern, delayed diagnosis, lethality. ISS 16
defined polytrauma.
Results
The undertriage rate (ISS 16, no whole-body MSCT) was 26.3%
(n=19), the overtriage rate (ISS < 16, whole-body MSCT) was 20.8% (n=15). All
patients subject to undertriage underwent region specific MSCT. The mean
ISS was 26.5 (range 2-75). Typical mechanisms of injuries were motor vehicle
accidents (59.7%) and falls from height (33.3%). Injuries to the head and face
were most common (52.8% and 25.0%), followed by extremitiy (51.4%),
thoracic (36.1%) and abdominal (19.4%) injuries. Delayed diagnosis occurred
in 3 cases. Lethality was 8.3%; in 4 of 6 patients trauma-related death was
caused by injuries to the head.
Conclusion
An adult triage rule for the indication of whole-body MSCT in
children does not seem to be applicable due to high under- and overtriage
rates. Knowledge of epidemiologic data can help to improve radiological
trauma algorithm in the multiple injured child emphasising modalities with low
radiation exposure.
B-0033 10:48
Feasibility of a dual-room sliding gantry CT concept for initial evaluation
of trauma patients
C. Frellesen, M. Böttcher, J. Kerl, J.L. Wichmann, T.J. Vogl, R.W. Bauer;
Frankfurt a. Main/DE (
[email protected])
Purpose: To evaluate the time-saving potential of a dual-room sliding gantry
CT system in comparison with a routine single-room CT for initial assessment
of patients in the trauma room.
Methods
and Materials: We compared the mean amount of time between
initial admittance of the patient to the trauma room, start of the CT scan and
end of initial trauma evaluation. 30 patients each were evaluated using a
traditional single-room CT and a novel dual-room sliding gantry CT. Statistical
analysis was performed using the Wilcoxon-Mann-Whitney-test and Fisher's
exact test.
Results
Patient groups were comparable as to sex, age and Injury Severity
Score (p> 0.66). Median time from patient arrival to start of the diagnostic CT
was significantly shorter with sliding gantry CT (15.4 min vs. 21.2 min,
p < 0.001). Median time between trauma room admission and discharge was
also significantly shorter with the dual-room concept (41.3 min vs. 62.1 min,
p < 0.001).
Conclusion
The dual-room sliding gantry CT concept allows for significant
time savings in the initial evaluation of trauma patients. Furthermore, it reduces
necessary patient transfer and manipulation of bearing devices.
B-0034 10:57
CT and MR track reconstruction of experimentally produced stab wounds
C. Giraudo1, P. Fais1, G. Cecchetto1, R. Boscolo-Berto1, M. Toniolo1, G. Viel1,
F. Tagliaro2, D. Miotto1; 1Padua/IT, 2Verona/IT (
[email protected])
Purpose: To measure by computed tomography (CT) and magnetic resonance
(MR) the length of stab wounds (SWs) experimentally produced on human
calves. Only a few data on the CT features of SWs are available in the clinical
and forensic literature and, to the best of our knowledge, MR data are still
missing.
Methods
and Materials: Ten SWs were inflicted on human legs surgically
amputated for medical reasons using a ceramic knife perpendicularly oriented
to the skin (depth of SWs varying between 3.0 and 6.0 cm). CT and MR scans
were performed before stabbing; with the knife inside the wound track (only CT
scans); and before/after filling each wound with the contrast medium (1:10
dilution of Omnipaque 300 GE Healthcare® with ultrasound gel). The depth of
the wound tracks was measured by an experienced radiologist (blind to the
experimental conditions) using Osirix (Open Source) software.
Results
CT and MR measurements underestimated the depth of SWs injuries
with a mean error of 6.9% (range: -33.5%-17.4%) and 6.7%, respectively
(range: -20.9%-14.4%). There was no statistical difference between CT and
MR measurements.
Conclusion
Our preliminary results show that CT and MR investigations of
SWs filled up with contrast medium provide consistent and reproducible data
on the depth of the inflicted injury. Further efforts will be made to improve the
injection modality of the contrast medium, in order to minimise underestimation
errors.
B-0035 11:06
Image quality of iterative reconstruction in cranial CT imaging:
comparison of model-based iterative reconstruction and adaptive
statistical iterative reconstruction
S. Notohamiprodjo, Z. Deak, F. Meurer, F. Mück, L. Geyer, M.F. Reiser,
S. Wirth; Munich/DE (
[email protected])
Purpose: CCT is a frequent examination in emergency departments. Model-
based iterative reconstruction (MBIR) is the successor of adaptive statistical
iterative reconstruction (ASIR), promising a more effective reduction of image
noise and improved spatial resolution. In this study, we compare the effects of
MBIR and ASIR in CCT.
Methods
and Materials: 100 trauma patients received CCT according to the
institutional standard protocol (120 kV, 260 mAs, 20 mm detector collimation,
0.984 pitch). Raw data sets and multiplanar reformations (MPRs) of 2.5 mm
were reconstructed with ASIR and MBIR. Two radiologists blinded to the
reconstruction algorithm evaluated the depiction of anatomical structures and
amount of artefacts using a semi-quantitative scale (0:non-diagnostic, 1
impaired, 2:sufficient; 3:good, 4:excellent). Data were analysed with Mann-
Whitney U test and ANOVA. Mean attenuation values (MAV) and standard
deviation (SD) were measured for white matter (WM) and liquor space (LS).
Results
MBIR significantly reduced streak artefacts better than ASIR. IQ of
MBIR were rated significantly superior than ASIR images with median scores
of 3 and 2, respectively. SD of WM especially in the posterior fossa was
significantly lower in MBIR MPRs (4.86 ± 1.95; 4.79 ± 2.34) in comparison to
ASIR (5.53 ± 2.15; 5.91 ± 2.93); (p < 0.05). MAVs of WM were significantly
higher in ASIR than in MBIR.
Conclusion
Our results suggest significant improvement of IQ with MBIR
compared to ASIR in CCT of trauma patients. MBIR being a more accurate
reconstruction algorithm could represent an effective method to decrease the
radiation dose of CCT.
B-0036 11:15
Detection of blunt biliary injuries using hepatocyte-specific contrast-
enhanced MR cholangiography
Y.-C. Wong, L.-J. Wang, C.-H. Wu, H.-W. Chen, C.-J. Fu; Gueishan/TW
(
[email protected])
Purpose: We are to investigate the hepatocyte-specific contrast-enhanced
magnetic resonance cholangiography (HEMRC) for the detection of blunt
biliary injuries.
Methods
and Materials: From May 2012 to September 2013, twelve patients
of major blunt liver trauma consented to be enrolled in this study. The HEMRC
was acquired at 10, 20, 30 and 90 minutes respectively after intravenous
injection of hepatocyte-specific contrast medium (Gd-EOB-DTPA). We
compared the diagnostic performance of HEMRC of different acquisition times
for the detection of biliary injuries. Medical charts were reviewed for course of
treatments and final diagnosis.
Results
MRI of all patients showed traumatic cysts in the injured liver. Among
them, HEMRC of nine patients detected biliary injuries evidenced by
extravasation of biliary contrast medium. Biliary extravasation was first
detected at 10 minutes (n=1), 20 minutes (n=3), 30 minutes (n=2), 90 minutes
(n=3). All were best visualised on HEMRC acquired at 90 minutes. Of the
traumatic cysts in three patients without biliary extravasation, two were
hematomas, one was abscess. Of the nine patients with biliary injuries, four
received catheter drainage, five were treated with observation. All had clinical
improvement and were discharged.
Conclusion
Blunt biliary injuries can be detected on HEMRC. The
extravasated biliary contrast medium is best seen at a delayed hepatobiliary
phase acquired at 90 minutes after intravenous injection of hepatocyte-specific
contrast medium (Gd-EOB-DTPA).
S144
B A C D E F G
Thursday
Author Disclosures:
Y. Wong: Research/Grant Support; Chang Gung Medical Research Project. L.
Wang: Research/Grant Support; Chang Gung Medical Research Project. C.
Wu: Research/Grant Support; Chang Gung Medical Research Project. H.
Chen: Research/Grant Support; Chang Gung Medical Research Project. C.
Fu: Research/Grant Support; Chang Gung Medical Research Project.
B-0037 11:24
Clinical impact of chest and abdominal CT on emergency patients
M. Brambati, C. Messina, R. La Rocca, G. Togni, L.M. Sconfienza,
F. Sardanelli; San Donato Milanese/IT (
[email protected])
Purpose: To evaluate the impact of computed tomography (CT) examinations
in determining a management change of patients admitted to the emergency
department (ED), quantifying therapeutic variation determined by CT scans.
Methods
and Materials: We prospectively analysed thoracic/abdominal CT
examination requests from our ED, from October 2012 to March 2013. Before
each CT, we asked the ED physicians to provide the most-likely diagnosis (12
choices were offered, including a wide range of ED diseases) and the most
appropriate foreseen management without CT scan information (admit to
hospital, keep in observation, patient discharge). Once CT was performed, ED
physicians were asked to evaluate the concordance between therapeutic
management before and after CT, by evaluating CT report as following: not
reliable, not confirming clinical diagnosis (l evel 1), confirming clinical diagnosis
without (level 2) or with (level 3) new information, change of diagnosis (level 4).
Furthermore, we defined as a major change the sum of level 1 and 4, and as a
minor change the sum of level 0, 2 and 3.
Results
We analysed 300 CT scans in 300 patients. CT examination was able
to change the planned treatment in 202 cases (67%) and to confirm it in 98
cases (33%). Concerning score level on patients' management, a major
change in planned treatment was obtained in 112 cases (56%) and a minor
change in 90 cases (44%).
Conclusion
CT examination in ED patients permitted a planned treatment
change in 67% of cases and in 56% of cases determined a major variation. CT
represents a predictor for hospital ED admission or discharge.
B-0038 11:33
Whole-body CT-based imaging algorithm for multiple trauma patients:
radiation dose and time to diagnosis
S. Gordic, S. Hodel, H.-P. Simmen, G. Wanner, K. Sprengel, H. Alkadhi;
Zurich/CH (
[email protected])
Purpose: To determine the number of radiological investigations, associated
radiation dose, and time to diagnosis in multiple trauma patients before and
after introduction of whole-body CT (WBCT) as primary diagnostic tool in early
trauma care.
Methods
and Materials: 120 consecutive patients assessed before the
Introduction
and 120 consecutive patients assessed after the introduction of
WBCT into our hospitals' trauma algorithm were compared regarding number
and types of CT, X-ray and FAST examinations, radiation dose, and time to
primary trauma-related diagnosis.
Results
In the WBCT cohort the number of CT studies of the head, cervical
spine, chest and abdomen was significantly (P <.001) higher as compared to
the non-WBCT cohort. In contrast, the number of X-ray examinations of the
cervical spine, chest and pelvis and the number of FAST was significantly
(P <.001) higher in the non-WBCT cohort. There were no significant (P=.56
and P=.30) differences between cohorts regarding the number of X-rays of
upper and lower extremities. We found significantly (P <.001) higher effective
doses in the WBCT as compared to the non-WBCT cohort but also significantly
(on average 29.5mSv vs 15.9mSv per patient, P <.001), but less additional
imaging studies were needed in the WBCT cohort (P <.001). Additionally, the
time to primary trauma-related diagnosis was significantly shorter in the WBCT
cohort (on average 0.19h vs 1.24h per patient, P <.001).
Conclusion
After introduction of WBCT into our trauma algorithm, overall
radiation doses were higher in patients, but less additional imaging studies
were needed and the time to obtain the primary trauma-related diagnosis was
shorter.
B-0039 11:42
Risk factors for non-compliance with recommendations by emergency
radiologists
J.O. Johnson, W. Shuaib; Atlanta, GA/US (
[email protected])
Purpose: To identify risk factors associated with non-compliance of
recommendations made by emergency radiologists.
Methods
and Materials: Between March 2012-August 2012, we reviewed
20000 consecutive emergency department patients receiving imaging at two
university hospitals to assess how often emergency radiologists made
recommendations, how often they were followed and what factors were
associated with non-compliance. The data was extracted from medical records
and the hospital information system: recommendation in imaging report, age,
sex, race, insurance status, primary care contact, distance from the hospital to
patient residence, and primary language. Recommendations were categorised:
1_immediate follow-up; 2_follow-up 1-4 weeks; 3_follow-up 1-3 months;
4_follow-up 4-6 months; 5_follow-up 7-12 months and 6_clinical correlation.
Results
We identified 1650 recommendations (1650/20000=8.25%). Using a
one to one logistic regression analys is, the following factors were significant
(p < 0.05) when evaluating non-compliance: increasing age, no primary care
physician, lack of insurance, increased distance from hospital and extended
follow-up interval. Primary language was not a significant factor in non-
compliance.
Conclusion
Emergency radiologists rarely make recommendations.
Immediate and short-term interval follow-up recommendations are more likely
to be followed. Decreased compliance is associated with extended interval
follow-up recommendations. The risk factors for non-compliance are
multifactorial and include age, primary care physician status, insurance and
distance. Primary and/or referring physicians should take notice of these
compliance trends and mitigating factors; adopt systematic safety measures to
ensure compliance to counsel and educate patients about the importance of
imaging recommendations.
B-0040 11:51
Can CT oesophagography reliably diagnose penetrating oesophageal
injury in the trauma population? Preliminary data
W. Conradie, F. Gebremarium; Bloemfontein/ZA (
[email protected])
Purpose: To measure the sensitivity and specificity of CT oesophagography
(CTE) in diagnosing penetrating oesophageal injury. To determine the
diagnostic confidence of the radiologist in detecting these injuries with the use
of CTE only. Finally, to determine if CTE can be used as the only imaging
examination in penetrating neck trauma to exclude oesophageal injury.
Methods
and Materials: Prospective, cross-sectional analytical study was
done at Pelonomi Tertiary Hospital in Bloemfontein, South Africa, between
December 2012 and November 2013. All adult trauma patients with suspected
penetrating oesophageal injuries, who required emergency CTA, were
considered for the study. An oral contrast solution was administered before the
CTA study. All CT findings were confirmed by other imaging methods. Images
were evaluated separately by two independent general departmental
radiologists.
Results
Sixty (60) patients qualified for the study. Fifty-four (90%) were male.
Knife wounds were the mechanism of injury in 83% of patients. Fourteen (14)
confirmed injuries (8 oesophageal and 6 in the hypopharynx) were all detected
by CTE. One hypopharyngeal injury diagnosed intra-operatively was missed by
CT and fluoroscopic esophagography (C TE sensitivity of 93%). CTE specificity
was 82% (8 false positives) and 91% (4 false positives) respectively. The two
radiologists were positive to very confi dent of their findings in 80 and 88% of
cases respectively.
Conclusion
Good sensitivity and specifici ty were achieved by both
radiologists using CTE. Preliminary data suggests that CTE is reliable in
detecting penetrating oesophageal injuries and that general radiologists will be
confident in using this examination.
10:30 - 12:00 Room E1
Musculoskeletal
SS 110
Shoulder and wrist
Moderators:
S. Morozov; Moscow/RU
M. Reijnierse; Leiden/NL
B-0041 10:30
The Mick Jagger position: a new manoeuvre for the intra-articular biceps
ultrasound visualisation
G. Azulay
1, P. Omoumi2, G. Aguilar1, J. Monres3, M. Brandao4;
1Buenos Aires/AR, 2Lausanne/CH, 3Goiania/BR, 4Ribeirao Preto/BR
(
[email protected])
Purpose: To demonstrate the feasibility of a new dynamic ultrasound
manoeuvre, consisting in abduction and ex ternal rotation, for the visualisation
of the intra-articular course of the long biceps tendon above the humeral head
to its insertion on the glenoid.
Methods
and Materials: A cadaveric study was performed to demonstrate the
course of the tendon, as well as the presence of an acoustic window between
the acromion and the coracoid process during the manoeuvre. A prospective
study was performed on 40 asymptomatic subjects of various age, as well as
10 patients referred for shoulder pain, in whom a correlation to MRI was also
S145
B A C D E F G
Thursday
obtained. Two observers graded the presence of an acoustic window, as well
as the visibility of the biceps tendon on a scale from 1 to 4.
Results
The visibility of the biceps tendon was diagnostic in 83% (n=36) 33 of
the 40 asymptomatic subjects. In the 10 pathologic shoulders, the biceps
tendon was visible in its intra-articular course in all patients. Ultrasound
demonstrated 4 cases of tendinosis (tendon hypertrophy and/or loss of fibrillar
pattern) and 1 synovitis surrounding the intra-articular biceps tendon, in
correlation with MRI.
Conclusion
The manoeuvre in abduction external rotation allows the
evaluation of the biceps tendon in its intra-articular course to its insertion on
the glenoid in up to 83% of subjects.
B-0042 10:39
A new dynamic manoeuvre to differentiate complete vs. partial distal
bicep tears at ultrasound
G. Azulay
1, I. Rossi1, P. Omoumi1, M. Brandao2; 1Buenos Aires/AR,
2Ribeirao Preto/BR (
[email protected])
Purpose: To demonstrate the feasibility and to assess the diagnostic value of
a dynamic ultrasound manoeuvre for the diagnosis of complete vs. partial tears
of the distal biceps tendon at the elbow.
Methods
and Materials: A cadaveric study on four specimens was performed
to demonstrate the movements of the di stal biceps tendon during passive
prono-supination of the forearm, before and after the creation of partial (50%)
and complete (100%) tears of the tendon, with integrity of the lacertus fibrosus.
15 patients, including 4 patients with a complete tendon tear, 1 patient with a
partial tendon tear and 10 normal tendons were studied independently by two
observers. Before the examination following a conventional technique, the
dynamic passive prono-supination manoeuvre was performed while the tendon
was examined in the transverse plane by the observers, blinded to the final
diagnosis.
Results
The cadaveric study showed that the manoeuvre lead to an
anteroposterior movement of the distal biceps tendon in normal and partially
torn tendons, but not in completely torn tendons. The manoeuvre allowed
accurate diagnosis of complete vs. partial tendon tears in 100% of cases, with
surgery as a reference.
Conclusion
A manoeuvre of passive prono-supination of the forearm is useful
for the ultrasound diagnosis of complete vs. partial tears of the distal biceps
tendon.
B-0043 10:48
Ultrasound-guided block of suprascapular nerve as a treatment of
adhesive capsulitis: indications, technique and early results
C. Martini1, F. Lacelli2, A. Romani1, N. Gandolfo1, G. Serafini1; 1Genoa/IT,
2Pietra Ligure/IT (
[email protected])
Purpose: Adhesive capsulitis (AC) is characterised by pain and stiffness in
external rotation and abduction of the upper limb; physiatric rehabilitation (PR)
is often difficult.The suprascapular nerve (SN) supplies 70% of shoulder
sensitive innervation. US visualises the SN at the level of the spine of the
scapula.The purpose of this work is to show that SN block makes a more
lasting pain decrease than the intra-articular treatment of capsulitis and makes
the PR easier.
Methods
and Materials: 20 patients with clinical diagnosis of adhesive
capsulitis were randomised in 2 groups (A=10 F, y=45 ±3.2; B=10 F, y=44±3.6).
Group A was treated with US-guided intra-articular injection of 5 cc of
hydrocloride mepivacaine 2%, 40 mg of methylprednisolone and 6 ml (90 mg)
of hyaluronate. In group B, the US-guided perineural (at the level of the spine
of the scapula) injection of 5 cc of hydrocloride mepivacaine 2% was added to
the treatment. All patients began PR the day of treatment. All patients
underwent clinical (VAS scale and ROM index) both before than immediately
after the treatment, at 1 week and 1 month.
Results
VAS before: 8.9 (A), 9.1 (B); immediately after: 5.0 (A), 4.8 (B); at 1
week: 6.2 (A), 4.5 (B); at 1 month: 6.1 (A), 4.0 (B) (p < 0.01). ROM before:
100°(A), 95°(B); immediately after: 120°(A, B); at 1 week: 130°(A), 150°(B); at
1 month: 135°(A), 170°(B). We had not complications, in particular no deficit of
motion. In all patients of group B, we visualised the SN by ultrasound.
Conclusion
The role of physiatry in rehabilitation and reduction of pain is
fundamental.The SN block associated with intra-articular treatment allows an
improvement of PR.The SN block has a more lasting effect than intra-articular
treatment.
B-0044 10:57
Capsular laxity in atraumatic multidirectional instability of the shoulder:
value of MR arthrography including abduction and external rotation
images
C. Schäffeler
1, S. Waldt2, J.S. Bauer2, C. Kirchhoff2, B. Haller2, E.J. Rummeny2,
A.B. Imhoff2, K. Woertler2; 1Chur/CH, 2Munich/DE (
[email protected])
Purpose: To evaluate diagnostic signs and measurements for capsular laxity
on MR arthrography (MR-A) of the shoulder including abduction/external
rotation (ABER) images in patients with atraumatic multidirectional instability
(MDI).
Methods
and Materials: Twenty-one MR-A including ABER position of 21
patients (mean age: 27 years; 4 males, 16 females) with clinically diagnosed
MDI and 17 patients (mean age: 31 years; 12 males, 5 females) without
instability were retrospectively assessed by three radiologists. On ABER
position MR-A, the presence of a layer of contrast between the humeral head
(HH) and the anteroinferior glenohumeral ligament (AIGHL) (crescent sign) and
a triangular-shaped space between HH, AIGHL and glenoid (triangle sign)
were evaluated; centering of the HH was measured. On standard imaging
planes anterosuperior herniation of the rotator interval (RI) capsule and glenoid
version were determined.
Results
The crescent sign showed a sensitivity of 57%/62%/48% (observers
1/2/3) and a specificity of 100%/100%/94% in the diagnosis of MDI. For the
triangle sign, sensitivity was 48%/57% /48%, specificity was 94%/94%94%.
Presence of either sign showed high sensiti vity (86%/90%/81%) and specificity
(94%/94%/94%). A positive triangle si gn was significantly associated with
decentering of the HH (; < 0.000). Measurements of RI herniation, RI width,
and glenoid version were not significantly different between both groups.
Conclusion
Combined assessment of laxity signs on ABER position MR-A is
accurate in the diagnosis of capsular laxity in patients with atraumatic MDI,
whereas measurements on standard imaging planes appear inappropriate.
B-0045 11:06
Diagnostic value of arthro-MRI in the long head of biceps tendon
instability due to biceps pulley lesion of the shoulder
S. Mariani, A. La Marra, F. Arrigoni, A. Mancini, A. Barile, C. Masciocchi;
L'Aquila/IT (
[email protected])
Purpose: To evaluate the added value of the internal and external rotation
during arthro-MRI in identifying the LHBT instability and the possible
development of an antero-superior impingment (ASI).
Methods
and Materials: We retrospectively analysed MRI exam of 70 patients
who underwent arthro-MRI (1.5 T) and arthroscopy within the following 7-45
days. Patients had clinical suspicion of biceps pulley lesions. The shoulder was
studied (with dedicated coil) in neutral position, in internal and external rotation
and ABER in 12 patients.
Results
Patients were divided in 4 gro ups (Habermayer classification) and
evaluated for an unstable LHBT:10 patients had superior gleno-humeral
ligament (SGHL) tear (Type I),16 patients SGHL and supraspinatus (SSP)
tendon tears (Type II),21 patients SGHL and subscapularis (SSC) tendon tears
(Type III) and 23 patients SGHL, SSP and SSC tears (Type IV). At arthroscopy
2 patients were negative,8 patients had Type I,16 patients Type II,19 patients
Type III and 25 patients Type IV lesions. MRI internal and external rotation
showed an initial anteromedial subluxation of the LHBT in 8 patients with Type
II lesion and an anteromedial subluxation of the LHBT in all patients with Type
III and Type IV lesions.The dynamic tests during arthroscopy, confirmed LHBT
instability and ASI features in patients with Type III and Type IV lesions.
Conclusion
Only high grade lesions of biceps pulley can be associated with
LHBT instability. MRI external and internal rotation led to a better identification
of structures of the biceps pulley and the detection of LHBT instability could
suggest the presence of ASI.
B-0046 11:15
Ultrasound-guided percutaneous treatment of rotator cuff calcific
tendinitis: randomised comparison between one- and two-needle
procedure
G. Ferrero
1, E. Fabbro1, D. Orlandi1, L.M. Sconfienza2, F. Lacelli3, G. Serafini3,
E. Silvestri1; 1Genoa/IT, 2San Donato Milanese/IT, 3Pietra Ligure/IT
(
[email protected])
Purpose: US-guided percutaneous treatment of RCCT has been
demonstrated to be effective using one or two needles,but direct comparison
between the two methods has never been performed.Our aim was to compare
the technical and one-year clinical outcome of these two approaches.
Methods
and Materials: IRB approval and patients' informed consent were
obtained.100 patients to be treated for RCCT (77females,mean age
46years,range 32-70y)were randomised into two groups.GroupA (50
patients;mean visual analogue scale[ VAS]=7.8)was treated using an US-
guided 16G double-needle technique (local anesthesia,washing with warm
saline,intrabursal steroid),while groupB (50patients;mean VAS=7.4)was treated
S146
B A C D E F G
Thursday
using a 16G single-needle technique.Calcification appearance at
US (fluid,soft,hard),procedure time and ease of calcium
dissolution (subjectively scored as easy=1,intermediate=2,difficult=3)were
recorded.VAS follow-up was performed at 1.3,6 and12 months.Complication
rate was noted.Mann-Whitney U and Chi-square statistics were used.
Results
No immediate or delayed major complications were
encountered.Overall procedure duration in group A (489± 88s)was significantly
shorter (P <.001)than duration in group B (684 ±187s).Difference in procedure
duration and ease of calcium dissolution wa sn't significant when dealing with
fluid deposits (P=.683;P=.849),whereas it was significant for soft and hard
deposits (P=.006 and P <.001;P=.004 and P <.001,respectively).Post-
procedure bursitis occurred in 4/35 patients after 61± 10days in group A and in
5/35patients after 56 ±7days in group B (P=.874).In group A,VAS was 3.1 ±0.2
at 1 month,1.8± 0.3 at 3 months,1.4 ±0.2 at 6 months,1.0 ±0.3 at 1 year,while it
was 3.0±0.1.1.9±0.4.1.3±0.5.1.1±0.5 in group B (P.244).
Conclusion
One- and two-needle procedures are equally effective in treating
RCCT with no major complications.Two-needle procedure allows for
significantly reducing treatment time and appears to be much easier when
dealing with soft and hard calcium deposits.
B-0047 11:24
Imaging-guided therapeutic shoulder injections: prospective study
comparing the lateral extension of the acromion on conventional
radiographs with patients' outcomes
T.J. Dietrich, B.K. Moor, G.J. Puskas, C.W.A. Pfirrmann, J. Hodler,
C.K. Peterson; Zurich/CH (
[email protected])
Purpose: To compare the lateral extension of the acromion on conventional
radiographs with patient improvement in pain and shoulder function after
subacromial and glenohumeral injections.
Methods
and Materials: Institutional review board and informed consent were
obtained. Totally 307 patients were prospectively included after therapeutic
fluoroscopy-guided subacromial (n= 148 patients) or glenohumeral injections
(n= 159 patients) with local anaesthetics (lidocaine 2%) and long-acting
corticosteroids (40 mg of triamcinolone). Post-interventional outcomes were
assessed by the patient's global impression of change (PGIC) and visual
analogue scale (VAS) pre-injection and at 1 week and 1 month post-injection.
Two observers quantified the lateral extension of the acromion by the critical
shoulder angle (CSA) and the acromion index (AI) on anteroposterior
conventional radiographs. ANOVA and Chi-squared test served for statistics.
Results
Relevant 'improvement' one month after subacromial injection was
observed in 63% of patients compared to 64% of patients after glenohumeral
joint injection. Comparing the three CSA categories after subacromial injection
showed a higher percentage of 'improved' patients at 1 week (68.2% versus
45.1%) and significantly lower pain levels on the VAS scale at 1 month
(2.2 ± 1.9 versus 3.4 ± 3.0, p = 0.027) in patients with a short lateral extension
of the acromion. No significant association was noted between the clinical
outcome (PGIC and VAS scale) and the lateral extension of the acromion
(CSA & AI) after glenohumeral joint injections.
Conclusion
Shorter lateral extensions of the acromion were related with
better clinical outcomes in subacromial injections but not in glenohumeral
injections patients.
B-0048 11:33
Ultrasound-guided percutaneous injection for De Quervain's disease
using three different techniques: preliminary results of a randomised
controlled trial
D. Orlandi
1, G. Ferrero1, E. Fabbro1, G. Serafini2, E. Silvestri1,
L.M. Sconfienza3; 1Genoa/IT, 2Pietra Ligure/IT, 3San Donato Milanese/IT
(
[email protected])
Purpose: De Quervain's disease is a painful stenosing tenosynovitis of the first
dorsal compartment of the wrist, caused by a thickening of the retinaculum.
Ultrasound-guided intracompartmental steroid injections reported pain relief in
up to 97% of patients at 6 months follow-up with a rate of symptoms
recurrence up to 20%. We compared the efficacy and the outcome at 6 months
follow-up of three different ultrasound-guided treatment options for De
Quervain's disease.
Methods
and Materials: Excluding women with pregnancy-related disease, a
consecutive series of 26 patients who presented at our institution to be treated
for De Quervain's disease under ultrasound guidance entered our study.
Baseline and follow-up (1, 3, 6 months) evaluation included US measurement
of first dorsal compartment retinaculum maximum thickness, pain assessment
(VAS) and disability assessment (quickDASH). All procedures were performed
under US guidance with axial scan over the first extensor compartment, and
using a medial-to-lateral approach. Patients were randomised into three
groups: 1 ml metilprednisolone acetate (group 1; 8 patients, mean age
39±10years, mean baseline thickness= 1.6 mm, mean baseline VAS=6.4, mean
baseline quickDASH=53), 1 ml triamcinolone acetonide+15-day-delayed 2 ml
saline 0.9% (group 2; 8.44 ±9.1.3.6.0.56), and 1 ml triamcinolone
acetonide+15-day-delayed 2 ml low-weight sodium hyaluronate (group 3;
10.43±12.1.7.6.4.55).
Results
No adverse reactions occurred. At 1-month follow-up we found: group
1, mean thickness=0.5 mm, mean VAS=1 .5, mean quick DASH=22; gr oup 2,
0.6.1.4.23; group 3, 0.5.1.2.21. At 3-month follow-up: 0.5.1.1.21; 0.6.1.2.21;
0.4.1.1.21. At 6-month follow-up: 0.8.3.4.32; 0.6.2.1.26; 0.5.1.0.19. VAS and
quickDASH are graphically represented in Figure 1.
Conclusion
Ultrasound-guided intracompartment injection of triamcinolone
acetonide+sodium hyaluronate seems to represent a promising approach to
treat De Quervain's disease, reducing symptoms recurrence up to 6 months.
Author Disclosures:
D. Orlandi: Research/Grant Support; This research was partially founded by
the Young Researchers Grant 2013 awarded by the European Society of
Musculoskeletal Radiology.
B-0049 11:42
Ultra high-resolution C-arm CT arthrography: initial results in- and ex-
vivo
C. Von Falck, B. Meyer, F. Wacker, H. Rosenthal;
Hannover/DE (
[email protected])
Purpose: To report on initial results of direct C-arm CT arthrography using a
1x1 binning ultra high-resolution detector read-out.
Methods
and Materials: Direct bi- or tricompartmental arthrography of the
wrist was conducted according to standard procedures under fluoroscopic
guidance in 5 patients and 5 cadavers using an iodinated contrast agent
(Imeron 300, 1:1 dilution with NaCl) for C-arm CT or a mixture of an iodinated
and a gadolinium-based contrast agent (Imeron 300, Bracco and Magnevist
2 mmol/l, Bayer, 1:1) for combined CT/MRI. C-arm CT images were acquired
on a monoplanar angiography unit (Artis Q, Siemens, Erlangen, Germany)
using a 1x1 binning detector read-out with a field-of-view of 22 cm. Subjective
and objective image quality and patient workflow were compared with
conventional thin-collimated MDCT (ex-vivo) and 3 T MRI (in-vivo),
respectively.
Results
Image quality of C-arm CT arthrography was rated significantly higher
as compared to MDCT/MRI arthrography with respect to the delineation of
intrinsic ligaments, TFCC, cartilage, subchondral bone plates and trabecular
architecture. However, MRI added supplemental information on (teno-
)synovitis, bone marrow edema and soft-tissue injury. C-arm CT considerably
improved the patient workflow by enabling joint injection and CT scan at a
single modality as compared with the traditional two-step procedure.
Conclusion
Ultra high-resolution C-arm CT arthrography shows superior
depiction of intraarticular structures and improves patient workflow as
compared to MDCT/MRT arthrography.
Author Disclosures:
C. Von Falck: Research/Grant Support; Visage Imaging. B. Meyer:
Research/Grant Support; Visage Imaging, Siemens Healthcare. F. Wacker:
Research/Grant Support; Visage Imaging, Siemens Healthcare.
B-0050 11:51
Metallic artefacts from internal scaphoid fracture fixation screws:
comparison between C-arm flat-panel, cone-beam and multi-detector CT
T. Finkenstaedt, F. Morsbach, M. Calcagni, M. Vich, C. Pfirrmann, H. Alkadhi,
G. Andreisek, R. Guggenberger; Zurich/CH (
[email protected])
Purpose: To systematically compare artefact degree and image quality from
scaphoid fracture fixation screws between different CT modalities and radiation
dose protocols.
Methods
and Materials: CT acquisitions were acquired from six cadaveric
wrists with scaphoid screws in two different scanning positions (45° and 90°)
with MDCT, C-arm-based flat-panel (FP) and cone-beam (CB) CT, the latter
two with low- and standard radiation dose protocols each. Two radiologists
measured the mean cartilage attenuation and metal artefact-induced absolute
HU changes (=artefact extent) and evaluated different kinds of image quality
criteria, e.g. visualisation of the screw bone interface and artefacts degree,
using a five-point Likert-scale. Interreader-agreements were calculated (ICCs;
Cohen's Kappa) and mean absolute HU changes and ratings compared using
Friedman and Wilcoxon signed-rank tests.
Results
ICC and Kappa for Interreader-agreement were 0.58 and 0.51,
respectively. Mean cartilage attenuation di d not differ significantly among
modalities and no significant differences in artefact extent among different
screw types and scanning positions were noted (p> 0.05). In CBCT low- and
standard-dose acquisitions, significantly higher artefact extent emerged
compared to MDCT and FPCT (p < 0.05). Image quality was significantly better
(p < 0.05) and artefact degree significantly lower (p < 0.001) in MDCT
compared to both other modalities. Screw bone interfaces were better visible in
FPCT compared to CBCT (p < 0.05).
S147
B A C D E F G
Thursday
Conclusion
MDCT has shown less metal-induced artefacts and better overall
image quality than FPCT and CBCT. However, FPCT and CBCT still provide
sufficient image quality to serve as low-radiation-dose alternatives for
postoperative scaphoid bone imaging in future.
10:30 - 12:00 Room E2
Breast
SS 102a
Contrast and spectral mammography
Moderators:
I. Pereira; Ourém/PT
F. Thibault; Paris/FR
B-0051 10:30
Tumour size: dual-energy contrast-enhanced digital mammography
(CEDM) versus breast MRI
I. Leconte, M. Teodorescu, N. Michoux, L. Fellah; Brussels/BE
(
[email protected])
Purpose: Evaluation of the tumour size in patients with breast tumors using
dual-energy contrast-enhanced digital mammography and MRI.
Methods
and Materials: Twenty-two patients with 30 breast tumours (29
malignant, 1 benign) underwent contrast-enhanced digital mammography
(CEDM) and MRI before surgery. Images were read twice by two senior
radiologists. Inter-observer agreement and inter-technique agreement (mean
measurement from both observers) with regard to the size of the lesions were
assessed based on the intraclass correlation coefficient ICC (two-way model
for an absolute agreement where systematic differences are relevant) and its
95% confidence interval.
Results
Median size of the lesions at histology was 12 mm [4 mm; 200 mm].
Inter-observer agreement was excellent for both modality (ICC
MRI = 0.995
[0.987 - 0.998], ICC CEDM = 0.997 [0.994 - 0.999]). Inter-technique agreement
was excellent between CEDM and histopathology (ICC = 0.943 [0.882 - 0.972])
and slightly superior to the one observed between MRI and histopathology
(ICC = 0.850 [0.707 - 0.927]).
Conclusion
Both CEDM and MRI offer reliable means of evaluation of tumour
size with an excellent reproducibility of measurements. CEDM is at least as
efficient as MRI for evaluating tumour size.
B-0052 10:39
Can contrast-enhanced spectral mammography replace magnetic
resonance imaging in the detection and staging of breast cancer?
M.H. Helal, R.M. Kamal, R. Essam, I. Godda, S.M. Mansour, N. Alieldin,
N.M. Khalifa, N. ElSaid, A.A.I. El-Shaarawy; Cairo/EG
(
[email protected])
Purpose: To evaluate the diagnostic performance of contrast-enhanced
spectral digital mammography (CEM) versus dynamic contrast-enhanced
magnetic resonance imaging (DCE-MR) in the detection and staging of breast
cancer.
Methods
and Materials: In this institutional ethics approved prospective study,
we compared the performance of CEM with MRI on 70 patients. Standard
digital mammogram was done in the mediolateral oblique and craniocaudal
projections followed by low (22-33 kVp) and high (44-49 kVp) energy
exposures in the same projections. DCE-MR was set in the axial orientation
and post processed using maximum intensity projection and multiplanar
reconstruction images. Both examinations performed by IV injection of non-
ionic contrast agent. Outcomes of the surgi cal specimen or ultrasound guided
core biopsy were the gold standard of reference.
Results
The study included 33 benign (47%) and 37 (53%) malignant breast
lesions. The areas of contrast uptake had been correlated with abnormalities
seen on the conventional mammography. Both CEM and MRI were individually
assessed in the same group of cases. Multi centric and multifocal carcinomas
were detected by contrast mammograms in 29.7% (n=11) of malignant cases,
when only unifocal carcinoma was reported on conventional mammograms. In
the contest of malignancy, both modalities stood on the same land.
Enhancement detection of some benign lesions (n=5) was limited in CEM.
Statistical analysis yielded a sensitivi ty, specificity and accuracy of 93.7%,
66.6% and 80.6% compared to 93.7%, 86.6% and 90.3% for CEM and MRI,
respectively.
Conclusion
CEM is non-inferior to breast MRI in the detection and
characterisation of breast malignancy.
B-0053 10:48
Contrast-enhanced spectral mammography in women referred from the
breast cancer screening programme
M. Lobbes, U.C. Lalji, J. Houwers, P. Nelemans, M. Smidt, E. Heuts,
J.E. Wildberger; Maastricht/NL (
[email protected])
Purpose: Previous results showed that contrast-enhanced spectral
mammography (CESM) could increase diagnostic performance of
mammography. Diagnostic performance of CESM in a population with low
disease prevalence (30%) was not evaluated before.
Methods
and Materials: Women referred from breast cancer screening
underwent CESM. Two radiologists blinded for diagnosis provided BI-RADS
classifications for conven tional mammography and CESM. Statistical
significance of differences between ma mmography and CESM was calculated
using McNemar's test and receiver operating characteristic (ROC) curves were
constructed for both imaging modalities. Bland-Altman plots were created to
evaluate agreement between tumour diameter as measured by CESM, MRI,
and pathology.
Results
113 women were included (age 49-73 years). When compared with
conventional mammography, CESM increased sensitivity to 100.0% (+3.3%),
specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) , and NPV to 100.0%
(+2.9%). Differences between conventional mammography and CESM were
highly significant (p
< 0.0001). A similar trend could be observed for the ROC
curve. For conventional mammography, the AUC was 0.779. With CESM, AUC
increased from 0.197 to 0.976 (p
< 0.0001). Excellent agreement between
tumour diameter measured by CESM and breast MRI was observed, with a
mean difference of 1.0 mm with 95% limits of agreement of 8.3 mm. Excellent
agreement was also observed for the comparison of tumour diameter
assessed by CESM and histopathology, with a mean difference of 1.4 mm, but
with larger 95% limits of agreement of 25.0 mm.
Conclusion
CESM significantly increases the diagnostic performance of
conventional mammography, even in patient cohorts with a low prevalence of
breast cancer.
B-0054 10:57
Radiation exposure of contrast enhanced spectral mammography
compared to conventional mammography
C.R.L. Jeukens, U.C. Lalji, E.J. Meijer, M. Lobbes; Maastricht/NL
(
[email protected])
Purpose: Contrast-enhanced Spectral Mammography (CESM) shows
promising initial results, but comes at the cost of an increased dose as
compared to conventional mammography (Mx). Dromain reported a dose
increase of 20%, it being the only study adressing this issue. As CESM could
substitute Mx, our purpose is to assess dose increase of CESM with respect to
Mx.
Methods
and Materials: We retrieved radiation exposure related data (kV,
compressed breast thickness, glandularity, Average Glandular Dose (AGD)) for
60 CESM and 344 Mx patients. All examinations were performed on the same
mammograph (GE Senograph Essential/Senobright). The CESM examination
exists of a low (kV=26-31 kV, Mo/Rh or Rh/Rh) and high energy (kV=45-49,
Mo/Cu or Rh/Cu) exposure after administering iodine contrast. A conventional
(low-energy) as well as a contrast-enhanced (high-energy) mammogram are
obtained. Radiation dose values reported by the mammograph were validated
by phantom measurements.
Results
Dose values reported by the system were in accordance with our
measurements. Mean ± SD AGD for a single low and high energy CESM
exposure was 2.12 ±0.68 mGy and 0.68 ±0.22 mGy, respectively. The AGD
depends on compressed breast thickness and glandularity. Combined radiation
exposure was 2.80 ±0.88 mGy. Mean AGD for a single Mx exposure was
1.55±0.48 mGy, which is significantly lower than the low energy CESM
exposure (p < 0.001).
Conclusion
Compared to Mx, total radiation exposure of CESM is
significantly increased by 63%. This increase is different from previously
reported finding and presumably caused by differences in automatic exposure
control settings between CESM and Mx.
B-0055 11:06
The added value of dual-energy contrast-enhanced digital mammography
in breast cancer diagnosis
A. Chalazonitis, S. Liopiris, E. Feida, D. Goutzamanis, Z. Antoniou; Athens/GR
(
[email protected])
Purpose: To determine the benefit of dual-energy contrast-enhanced digital
mammography (CESM) performance in breast cancer diagnosis.
Methods
and Materials: 120 women, aged from 28 to 85 years (median age
56.4 years), with suspicious finding (s) in conventional digital mammography,
breast ultrasonography, or breast MR, underwent dual-energy CEDM in our
Radiology Department. The evaluation of the low-energy image was based on
morphology of the lesion (s). High-energy image evaluation was based on the
S148
B A C D E F G
Thursday
strength of contrast enhancement intensity, according to a qualitative scale of
contrast enhancement intensity, categorised in 4-steps. Type 0= no
enhancement, type 1= very low enhancement, type 2= moderate
enhancement, type 3= intense enhancement. Type 0 and type 1 findings were
considered to be probably benign, while type 2 and type 3 findings were
considered to be probably malignant. Histopathological analysis of the suspect
breast lesions was performed in all patients, after core or surgical biopsy.
Results
Histopathology confirmed 58 malignant and 62 benign lesions. There
was excellent correlation between proven breast malignancy and moderate or
intense lesion enhancement (53 of 68), as well as between benign lesions and
no, or very low enhancement (47 of 62). According to our findings, the positive
predictive value of the method is 78% the negative predictive value is 90%, the
specificity is 77% and the sensitivity is 91%.
Conclusion
Dual-energy CEDM can be used as a useful adjunctive tool and a
problem-solving method to diagnosti c conventional mammography in every-
day practice.
B-0056 11:15
Contrast-enhanced digital mammography: is it useful in detecting lesions
in oedematous breast?
N.A.E. ElDeib, N.M. Khalifa, S.M.S. Sharaf, M.H.H. Helal, O.M.M.N. Nada,
E.N. Nasr, O.M. Magdy, S. Farouk, E. Abbas; Cairo/EG
(
[email protected])
Purpose: To investigate the potential of using intravenous contrast material
with full-field digital mammography to facilitate the detection and
characterisation of lesions in the oedematous dense breast.
Methods
and Materials: The study included 36 Egyptian patients (age ranged
from 37 to 62 years, mean = 49.5 years) presenting by swollen breasts or
coming for follow-up after treatment either by chemotherapy or conservative
breast surgery. They underwent both conventional mammography and high-
energy post-contrast digital mammography and ultrasound breast examination.
Results
Two radiologists analysed the presence and pattern of contrast
uptake. Enhancement was detected in 23 cases and no detectable
enhancement in 13 cases. Two false negative cases were detected (one
invasive carcinoma post chemotherapy and one duct carcinoma in situ). Two
false positive cases were also detect ed (one diffuse granulomatous mastitis
and one diffuse interstitial mastitis). The calculated sensitivity, specificity,
positive and negative predictive values of CEDM were 93.9%, 89.6%, 93.9%
and 89.6%, respectively, as compared to 85.6%, 55.1%, 76.3% and 69.3% for
FFDM.
Conclusion
Dual-energy contrast-enhanced digital mammography is a useful
technique in identification of lesions in mammographically dense oedematous
breasts and capable of demonstrating lesions that are not visible at standard
mammography. CEDM is useful in follow-up of cases presenting by edema
after conservative breast surgery and chemotherapy.
B-0057 11:24
Characterisation of breast lesions with spectral mammography: results
on tissue specimens and first clinical cases
F. Kilburn-Toppin
1, P. Willsher2, K. Erhard3, E. Fredenberg4, E. Moa4,
D. Dance5, M.G. Wallis2; 1Bury St Edmunds/UK, 2Cambridge/UK,
3Hamburg/DE, 4Solna/SE, 5Guilford/UK (
[email protected])
Purpose: Round lesions are a common mammographic finding; techniques to
improve characterisation at screening may reduce recalls. Our study aims to
determine x-ray attenuation of solid breast lesion specimens to establish
whether they could be distinguished fr om cystic lesions by spectral imaging
(SI).
Methods
and Materials: 73 fixed tissue samples of solid breast lesions, 50
samples of cyst fluid and 50 of water were imaged on a prototype Philips
MicroDose SI mammography system. Energy dependent x-ray attenuation was
measured from the photon counts in the high and low-energy images and
mapped to equivalent thicknesses of aluminium and polymethyl methacrylate.
In addition, 40 cysts and 26 solid lesions in 56 women have been imaged and
characterised in vivo on a CE-marked clinical SI system following delineation of
each lesion by a radiologist.
Results
25 fixed tissue samples were excluded (DCIS/benign/technical
reasons). Attenuation of the remaining 48 biopsy proven malignant samples
was significantly different from cyst attenuation at 95% significance level.
Standard deviation of the attenuation of tumours was 2-4 times larger than cyst
samples, and 7-14 times larger than water samples. 2 of the fixed tumour
samples overlapped with the distribution of cyst fluid samples. On the clinical
system, our initial algorithm has correctly predicted all solid lesions.
Conclusion
Results demonstrate large sample variability but only small
overlap between attenuation of cyst fluid and fixed tumour samples, suggesting
it may be possible to distinguish cystic from solid lesions. Initial clinical results
are promising, justifying continuing a clinical study.
Author Disclosures:
K. Erhard: Employee; Philips. E. Fredenberg: Employee; Philips. E. Moa:
Employee; Philips. M. Wallis: Grant Recipient; Philips.
B-0058 11:33
Added value of contrast-enhanced spectral mammography (CESM) as
part of a one stop breast unit
A.-M. Tardivel, C.S. Balleyguier, S. Canale, S. Delaloge, C. Mazouni,
M.-C. Mathieu, C. Dromain; Villejuif/FR (
[email protected])
Purpose: To assess the added value on treatment management of contrast-
enhanced spectral mammography (CESM) in adjunct to mammography and
ultrasound in breast cancer in One Stop Breast unit.
Methods
and Materials: 152 women with a suspicious or undetermined breast
lesion on mammogram ± ultrasound underwent bilateral CESM in a one shot
breast post-screening unit between September 2012 and June 2013. CESM
images were blindly retrospectively revi ewed by two radiologists, to estimate
BI-RADS categories and probability of malignancy (7 categories scale). Each
lesion was confirmed histologically or by fol low-up for typical benign lesions.
Diagnostic performances were estimated. Changes of medical and surgical
strategy were recorded.
Results
223 lesions were detected including 174 malignant lesions (137
infiltrative ductal carcinoma, 19 lobular infiltrative carcinoma, 8 ductal
carcinoma in situ) in 124 / 152 patient s (82%). CESM sensitivity, specificity,
positive predictive value and negative predictive value were 94%, 71%, 92%
and 76%, respectively, with 14 false-posi tive and 11 false-negative findings.
CESM changed diagnostic and treatment strategy in 33 (22%) patients,
detecting additional malignant lesions in 22 patients, with a more extensive
surgery (n=21) and neoadjuvant chemotherapy (n=1). A biopsy was avoided in
11 patients with negative CESM, for whom a benign lesion was confirmed by
follow-up. Diagnostic and treatment changes according CESM were
independent from breast density, tumour type and mammographic/sonographic
findings.
Conclusion
CESM may be performed easily in One Stop Breast unit and may
change significantly the diagnostic and treatment strategy in breast cancer
staging.
B-0059 11:42
Second-look digital breast tomosynthesis (SL-DBT) in assessing
incidental findings (IFs) at contrast-enhanced magnetic resonance
imaging (CE-MRI) in patients with newly diagnosed breast cancer
P. Clauser
1, A. De Nicolò1, V. Londero1, R. Girometti1, C. Zuiani1,
M. Bazzocchi1, F. Sardanelli2; 1Udine/IT, 2San Donato Milanese/IT
(
[email protected])
Purpose: To test if SL-DBT, i.e. the re-evaluation of DBT images after CE-
MRI, helps assessing IFs at CE-MRI in patients with newly diagnosed breast
cancer.
Methods
and Materials: Two experienced readers in consensus
retrospectively reviewed the examinations of 43 patients who underwent DBT
and CE-MRI from May 2012 to January 2013, looking for a DBT correlate of
IFs at CE-MR. Standard of reference was histology for CE-MRI suspicious
findings (ACR-BIRADS-3-5) and imaging follow-up for CE-MRI non-suspicious
findings (ACR-BIRADS-1-2). Fisher exact test was used.
Results
A total of 32 CE-MRI IFs were detected in 24 patients: 18 BIRADS-2
and 14 BIRADS-3-5. A DBT correlate was found in 12/24 IFs (38%) overall,
8/14 (57%) MR-BIRADS-3-5 and 4/18 (22%) MR-BIRADS-2 IFs, with
borderline significance (p=0.080). Maligna ncy was histologically confirmed for
10/14 CE-MRI IFs; 6 of these 10 additional malignancies (60%) had a DBT
correlate with suspicious features: 3 in vasive lobular; 2 ductal carcinoma in
situ; and 1 invasive ductal. A significantl y lower rate of DBT correlate (6/22,
27%), was found for non-suspicious CE-MRI IFs, all with benign features
(p=0.005).
Conclusion
A DBT correlate was more frequent for malignant than for benign
CE-MRI IFs. SL-DBT has the potential to confirm more than 50% of suspicious
CE-MR IFs. However, the absence of a DBT correlate does not warrant to
avoid MR-guided biopsy.
B-0060 11:51
The 3D mammography: the imaging of the future?
R. Ferré1, C.S. Balleyguier2, P. Goumot3, B. Mesurolle1; 1Montreal, QC/CA,
2Villejuif/FR, 3Paris/FR (
[email protected])
Purpose: To assess the benefit of real three-dimension mammogram
(3DSDM) in diagnosis improvement and cancer detection in comparison with
2D digital mammography.
Methods
and Materials: The 3DSDM is processed by an additional low-dose
image acquired with a 4-degree angulation compared to cranio-caudal
acquisition. This acquisiti on time takes 1 minute more and the dose is 30%
lower. The resolution is 50 8m. Both images are treated as a stereo-pair in the
3DSDM system. Monitor allows magnification, and 2D and 3D can be switched
as well. 1110 mammograms were performed from March 2012 until April 2013,
including 1075 patients whose mean age was 60 (21.91). The study was
prospective and board-approved. 3 radiologists who were blinded to each other
S149
B A C D E F G
Thursday
Results
read 2D then 3D mammograms and evaluated 3D benefit with a 3-level
scale : 0 for no benefit, 1 for moderate and 2 for excellent. All cases of cancers
were histologically proven and were also evaluated.
Results
For 958 mammograms (86%), the readers had the same opinion
about the benefit of 3DSDM : grade 0, 1 & 2 were quoted in 8, 52 and 26% of
cases. Discordance was not influenced by BIRADS classification (heterogenity
test : p = 0.55) neither with microcalcification or masses (heterogenity test : p =
0.80). The readers had the same opinion of cancers in 96% of cases with a
moderate and excellent benefit (50% and 42% respectively).
Conclusion
3DSDM is a new helpful tool to interpret mammograms and
particularly in a significantly higher cancer detection rate.
10:30 - 12:00 Room F1
Oncologic Imaging
SS 116
Imaging in response assessment:
methodology and clinical results
Moderators:
K.S. Lee; Seoul/KR
M. Nadrljanski; Belgrade/RS
B-0061 10:30
Correlation of radiological presentation and response to TKI targeted
therapy in EGFR mutant and ALK rearranged advanced lung
adenocarcinomas patients
N. Moussa, C. Leduc, L. Faivre, J. Pignon, B. Besse, C. Dromain,
C. Caramella; Villejuif/FR (
[email protected])
Purpose: Amongst caucasian patients with lung adenocarcinoma, around 15%
exhibit epidermal growth factor receptor mutation (EGFRm) or anaplastic
lymphoma kinase rearrangement (ALK+). These tumours are associated with a
high response rate to specific targeted treatments, but the impact of the
radiological presentation on the treatment benefit is poorly known.
Methods
and Materials: We retrospectively reviewed patients with advanced
non-small cell lung cancer harbouring EGFRm and/or ALK+ that were included
in a clinical trial at Gustave Roussy (MSN trial). A central review of all the
baseline clinical characteristics and CT images was performed to assess initial
tumour volume (volumetry software program LungVCAR, GE Healthcare),
number and type of metastatic lesions (brain, lung, adrenal, liver, bone).
EGFRm tumours were treated with gefitinib or erlotinib, and ALK+ tumours with
crizotinib. Multivariate statistical analyses were performed to correlate with
progression-free survival (PFS).
Results
Between june 2006 and january 2013, 405 patients were included in
the MSN. Amongst them, 97 patients were eligible, 80 EGFRm, 14 ALK+, 3
with both. There was no statistically significant difference between
oligometastatic (< 3 sites) and polymetastatic patients and according to volume
tumour ( 75 cm
3). None of the clinical characteristics of the
metastatic site had a detrimental effect on PF S, including 43 patients with brain
metastasis.
Conclusion
In patients with EGFRm or ALK+ lung cancer under targeted
therapy, the initial tumour burden or the presence of brain metastases was not
correlated with a poorer benefit.
B-0062 10:39
Radio-pathological correlation in HCC treated by transarterial
chemoembolisation: comparison between RECIST, mRECIST and EASL
criteria
M. Dioguardi Burgio
1, M. Ronot2, O. Bruno2, C. Francoz2, V. Paradis2,
F. Durand2, L. Castera2, J. Belghiti2, V. Vilgrain2; 1Palermo/IT, 2Clichy/FR
(
[email protected])
Purpose: To compare the performances of RECIST1.1, mRECIST, and EASL
criteria for tumoural necrosis evaluation in a consecutive series of patients
treated with transarterial chemoembolisation (TACE) before liver
transplantation (LT) for hepatocellular carcinoma (HCC).
Methods
and Materials: Between 2006 and 2012, all patients treated with at
least one session of TACE before LT for HCC were identified. Response to
treatment was evaluated by 2 independent readers on the last CT before LT
according to RECIST1.1, mRECIST, and EASL criteria. Imaging response was
compared to the tumoral necrosis assessed by pathology on the liver explant.
Inter-reader agreement for the tumoural response was evaluated by the kappa
statistic. Factor associated with a major ( > 90%) necrosis were tested by
multivariate analysis.
Results
Population included 58 patients with 88 HCC treated with 94 TACE
sessions. 51 nodules (58%) showed major necrosis. Among them, lesions
were classified as complete response according to RECIST1.1, mRECIST and
EASL in 2 (4%), 47 (92%) and 47 (92%) for reader 1, respectively, and 1 (2%),
45 (88%) and 45 (88%) for reader 2, respectively. Despite similar
performances with mRECIST and EASL, only mRECIST was correlated with
major necrosis on multivariate analysis for both readers (p < 0.0001). Inter-
observer agreement was substantial for RECIST1.1 (k=0.65 ± 0.08), mRECIST
(k=0.78 ± 0.07), and EASL (k=0.75 ± 0.07).
Conclusion
mRECIST and EASL criteria showed better correlation with major
tumoural necrosis than RECIST1.1. mRECIST showed better correlation with
tumoural major necrosis and should be used to evaluate response to TACE.
B-0063 10:48
Investigating changes in tumour volumes for defining limits for stable
disease by total tumour volumetry criteria in therapy response
assessment of hepatocellular carcinoma
A. Singh, W. Cai, S. Saini, G. Harris; Boston, MA/US (
[email protected])
Purpose: Limits for stable disease according to total tumour volumetry (TTV)
criteria have been set between -65 and +73% change in total tumour volume
after treatment and is basically derived from extrapolation of bi-dimensional
RECIST-based measurements lacking validation for specific tumour groups.
Our aim is to generate receiver-operating-characteristic (ROC) curves for
defining a more reliable limit for stable disease for assessing therapy response
in Hepatocellular carcinoma's (HCC) with total tumour volumetry criteria.
Methods
and Materials: Consecutive pre-treatment and post-treatment MDCT
datasets of 63 consecutively treated HCC patients were obtained for estimation
of interval change in total tumour volume (TTV) using semi-automated 3D
segmentation techniques. Area-under-curve (AUC) was generated for various
thresholds ( ±20%, ± 30%, ± 40%, ± 50%, ± 60%, ±70%) along with the current
proposed TTV stable disease inclusion limits (-65 to +73% change).
Progression-free survival time from start of treatment was used as dependent
variable.
Results
The stable limit range for total tumour volumetry criteria
between ±50% revealed a better AUC [AUC=0.727; 95%CI=0.60-0.83]
compared to other set limits for stable disease. The stable range set at ±60%
was also closer to most optimum (AUC=0.707). The ROC-AUC for existing
TTV criteria for stable disease (-65 to +73%) was less than the above two
ranges (AUC=0.688).
Conclusion
Better prediction of therapy response in HCC by TTV criteria was
achieved by setting limits of stable disease between ±50 and ±60% in this
study compared to currently proposed limits of -65 to +73%, thus necessitating
further validation on larger cohort.
Author Disclosures:
A. Singh: Grant Recipient; NIH/NCI Proton beam federal share grant (PI) 2012
& 2013; Sarcoma Foundation of America 2010 Grant -PI; RSNA 2009 fellow
grant -PI. Research/Grant Support; RSNA fellow grant 2009; NIH/NCI Proton
Beam Federal Shre Grant. S. Saini: Consultant; GE HEALTHCARE, PHILIPS,
BRACCO. G. Harris: Advisory Board; Fovia Inc.
B-0064 10:57
What does FDG-PET activity tell us about morphological changes in
colorectal liver metastasis treated with bevacizumab?
A.R. Seyal, F.D. Gonzalez-Guindalini, K. Parekh, P. Nikolaidis, V. Yaghmai;
Chicago, IL/US (
[email protected])
Purpose: To evaluate correlation of FDG-PET uptake with morphological
changes of colorectal liver metastases treated with bevacizumab.
Methods
and Materials: This HIPAA compliant study was IRB approved. Fifty-
four colorectal liver metastases in 22 patients treated with bevacizumab were
evaluated. For each patient, pre- and post-therapy CT scans and post-therapy
FDG-PET scan were evaluated. Based on FDG-PET, lesions were classified in
two groups: Responder (no uptake) or non-responder (positive uptake). Two
experienced abdominal radiologists blinded to FDG-PET results analysed the
CT images for changes in tumor morphology and categorised them as
responders (sharp margin) and non-responders (irregular margin).
Results
The mean interval time between the post therapy CT and FDG-PET
was 8 days. Based on tumor morphology, 12/54 (22.2%) lesions were
classified as responders and 42/54 (77.8%) lesions as non-responders. The
number of responder and non-responder lesions based on FDG-PET uptake
were 20/54 (37%) and 34/54 (63%), respectively. FDG-PET and tumor
morphology were concordant for response category in 40/54 (74.1%)
metastases. 3/54 (5.6%) metastases were classified as responders based on
morphology but demonstrated FDG-PET uptake after therapy, while 11/54
(20.3%) metastases classified as non-responders based on morphology
showed no uptake on post treatment FDG-PET. The FDG-PET sensitivity,
specificity, PPV and NPV to predict response based on tumor morphology
were 75%, 73.8%, 45% and 91.2%, respectively. FDG-PET predicted tumor
morphology (odds ratio: 8.45; 95% C: 1.93-37.03; P=0.005).
Conclusion
Changes in colorectal liver metastasis morphology and FDG-PET
uptake show high concordance in patients treated with bevacizumab.
S150
B A C D E F G
Thursday
Author Disclosures:
A.R. Seyal: Research/Grant Support; Educational Grant from Siemens
Healthcare. K. Parekh: Research/Grant Support; Educational Grant from
Siemens Healthcare.
B-0065 11:06
Very high-resolution ultrasound and elastography in melanoma lesion:
US-pathological correlations
C. Botar-Jid, R. Cosgarea, S. Ienil, S.D. Bolboac, M. Lenghel, D. Vasilescu,
S.M. Dudea; Cluj-Napoca/RO (
[email protected])
Purpose: The aim of this study was to evaluate the very high-resolution
ultrasound (US) in assessment of preoperative melanoma, especially by
correlation between US thickness of melanoma and the histopathological
thickness (Breslow index), being known that Breslow index positively correlates
with the probability of lymph node involvement and the risk of distant
metastasis.
Methods
and Materials: The study included 28 melanoma lesions identified
on 25 patients. A Ultrasonix equipment with 20-40 MHz linear transducer was
used for US evaluation. The relation between values obtained by 2D US
evaluation of the lesions (thickness and elastographic appearance) and value
obtained by histopathological examination (Breslow index) was investigated.
Results
The mean age of the investigated subject was of 57 ±15 years old.
Most investigated lesions were localised at lumbar region (17.86%, 95%CI
[7.27-35.59], where CI = confidence interval) and had a hypoecogen
homogenous 2D US aspect in 71% of cases (95%CI [50.13-85.59]). The
elastographic aspects of lesions were low or medium intensity in 43% and 39%
respectively. The US thickness (2.38 ±1.41 mm) proved significantly correlated
with Breslow index (2.61 ±1.19 mm) (r=0.9335, p=8.14•10-11). Furthermore,
the elastographic appearance of the lesion significantly correlated to both US
thickness (;=-0.490, p = 0.008) and Breslow index ( ;=-0.440, p=0.036).
Conclusion
The strong linearity between US thickness and Breslow index
obtained in our study and significant relation between elastographic
appearance of the lesion and Breslow index sustain the usefulness of US and
elastography in the assessment of skin melanoma lesions.
B-0066 11:15
The tumour response assessed with CT at 8 weeks from start of first-line
chemotherapy correlates with overall survival in metastatic colorectal
cancer
C. Suzuki
1, L.C.O. Blomqvist1, T.K. Guren2, K.M. Tveit2, B. Glimelius3;
1Stockholm/SE, 2Oslo/NO, 3Uppsala/SE (
[email protected])
Purpose: To study the relationship between early tumour response assessed
by computed tomography (CT) eight weeks from baseline and overall survival
(OS) in patients receiving first-line chemotherapy for metastatic colorectal
cancer (mCRC).
Methods
and Materials: A total of 520 patients who received bolus 5-
fluorouracil/folinic acid and oxalipla tin (Nordic FLOX), with or without
cetuximab, as first-line treatment for CRC in a randomised multicenter trial
(NORDIC VII, n=566), were eligible for this sub-study. Radiological response
was analysed according to response evaluation criteria in solid tumours
(RECIST 1.0). The relationship between the percentage change in sum of
tumour diameters from baseline to the first CT response evaluation and OS
was investigated by using Cox proportional hazards multiple regression model
and Kaplan-Meier survival analyses.
Results
Forty percentage decrease or more in the sum of tumour diameters
was a positive prognostic factor for OS. Any other magnitude of change in size,
even 20% or more increase (corresponding to progressive disease by RECIST
1.0) did not indicate shorter OS. A patient who had appearance of new
lesion (s) or progression of non-target lesion (s) had a significantly shorter OS
in both uni- and multivariate analyses.
Conclusion
Radiological tumour response assessed by CT at eight weeks
was related to outcome; a more than 40% decrease in tumour size was
associated with long OS, while appearance of new lesion (s) or progression of
non-target lesion (s) was a strong negative prognostic factor.
B-0067 11:24
Neoadjuvant radiochemotherapy response evaluation with MR and FDG-
PET/CT in rectal cancer: predictive value of combined quantitative
parameters of ADC and SUV compared with tumour regression grade at
histology
D. Ippolito, P.A. Bonaffini, D. Fior, C. Capraro, C. Trattenero, S. Sironi;
Monza/IT (
[email protected])
Purpose: To determine the clinical value of functional imaging,combining
quantitative parameters of ADC and SUVmax,before and after chemo-radiation
therapy,in prediction of tumor response of patients with rectal cancer,correlated
with tumor regression grade at histology.
Methods
and Materials: A total of 45 patients with biopsy proven diagnosis of
rectal carcinoma were enrolled in our study.All patients underwent whole body
18-FDG-PET/CT scan and a pelvic MR examination before (PET 1,MR 1) and
after neoadjuvant chemoradiation therapy (PET2,MR2).MR
scanning,performed on 1.5T magnet (Philips,Achieva),comprised T2-weighted
multiplanar imaging and in addition DW images with b-value of 0 and
1000 mm²/sec.On PET/CT the SUVmax of rectal lesion were calculated in
PET1 and PET2.The percentage decrease of SUVmax ( ,SUV) and
ADC (,ADC) value,from baseline to presurgical scan,were assessed and
correlated with pathologic response classified as tumor regression
grade (Mandard's criteria;TRG 1=complete regression,TRG5=no regression).
Results
At histology,according to Mandard's criteria,29 tumors (68%) showed
complete or subtotal regression (TRG1-2) and were classified as
responders;16 tumors (32%) were classified as non-responders (TRG3-
5).Considering all patients,the mean values of SUVmax in PET 1 was higher
than mean value of SUVmax in PET2 (p < 0.001),whereas mean ADC values
was lower in MR 1 than MR2 (p < 0.001).The best predictors for TRG response
were SUV2 (threshold of 4.4) and ADC2 (1.28x10-3 mm2/s),but combining in a
single analysis median quantitative value,the PPV in predicting different group
category response,related to TRG system,presented an overall AUC of 96%,
higher than DWI (88.2%) or SUVmax (93.3%).
Conclusion
In era of PET/MRI scanner,combination of DWI and PET/CT
represents the most feasible method to evaluate LARC patients,with accuracy
values higher than those reported for other imaging technique.
B-0068 11:33
Comparison between portal phase CT attenuation values and dynamic
contrast enhanced ultrasonography in the early evaluation of metastatic
renal cell carcinoma patients treated with anti-angiogenic treatment
M.-R. El Bejjani
1, L. Rocher2, M.-F. Bellin2, S. Koscielny1, B. Benatsou1,
N. Lassau1; 1Villejuif/FR, 2Kremlin-Bicêtre/FR (
[email protected])
Purpose: Our objective was to compare the evaluation using DCE-US at one
month and the CT-scan with calculation of density at 2 months for the
prediction of response in patients treated by tyrosine kinase inhibitors for
metastatic renal cell carcinoma.
Methods
and Materials: We performed DCE-US in one target at baseline and
D30. We selected patients with contrast-enhanced portal phase CT at baseline
and after 2 months to calculate PFS. Response assessment using the
Response Evaluation Criteria in Solid Tumors and the modified Choi criteria (a
region of interest encompassing drawn with Global Imaging software) was
performed in 5 targets including the DCE-US tumor. Results were correlated to
the PFS.
Results
A total of 81 patients were analysed. All had DCE-US at baseline and
one month. Forty four patients had CT-scan with contrast media injection for
Choi criteria analysis. The median of follow-up was 18 months. For DCE-US,
the decrease of 90 % of AUC at D 30 was correlated to the PFS (p =0.01). The
difference of PFS between the groups defined by this cut-point was 4 months
(bad responders) and 14 months (good responders). For the Choi criteria, the
preliminary results seem to be efficient to predict PFS.
Conclusion
RECIST is not reliable to early identify good responders. DCE-US
at one month could select patients with a poor PFS (p < 0.01) in order to
change treatment. Tumor density analysis at 2 months seems to be a good
indicator and will be confirmed with the final analysis.
B-0069 11:42
Comparing accuracy of dimensional and attenuation based criteria in
predicting clinical outcome in patients with renal cell cancer treated with
antiangiogenetic targeted therapy
C. Vancini, A. Spina, M. Totaro, V. Pollastri, N. Murri Dello Diago, E. Raisi,
A. Rocchi, A. Carnevale, M. Giganti; Cona/IT (
[email protected])
Purpose: Aim of the study was to compare the accuracy of different response
assessment criteria in the early evaluation of patients with metastatic renal cell
cancer (RCC) on antiangiogenic targeted therapy.
Methods
and Materials: 44 patients with advanced RCC were studied.
Standard contrast-enhanced CT (CECT) studies acquired before and three
months after the onset of tyrosine-kinase inhibitor therapy were retrospectively
evaluated. For each patient, response assessment to targeted therapy was
evaluated using: Mass, Attenuation, Size and Structure (MASS) criteria; Size
and Attenuation CT (SACT) criteria; modified Choi criteria (mChoi) and
Response Evaluation Criteria in Solid Tumo rs (RECIST); sensitivity, specificity
and accuracy were evaluated for each response criteria using as old standard
the clinical outcome at 250 days from baseline.
Results
Identifying patients with a progression free survival at 250 days
MASS and SACT ha d a sensitivity of 95.23% while mChoi and RECIST had a
sensitivity of 100%; the specificity was respectively of 52.17%, 56.52%,
56.52%, 60.86%, and the accuracy of 72.72%, 75%, 77.27%, 79.54%. The
negative predictive value (progression free disease at 250 days) was 92.3% for
MASS, 92.85% for SACT and 100% for mChoi and RECIST, while the positive
S151
B A C D E F G
Thursday
predictive value was MASS 64.51%, SACT 66.66%, mChoi 67.74% and
RECIST 70%.
Conclusion
Assessment of metastatic RCC target lesion on CECT, in a
cohort of 44 patients treated with antiangiogenic targeted therapy, using
dimensional and attenuation based methods shows in our casistic comparable
predictive value performances, with slightly better results for RECIST, for a
time to progression free cut-off of 250 days.
B-0070 11:51
Growth curves of renal masses from patients with von Hippel-Lindau
disease
G. Gennaro, C. Dal Bosco, G. Opocher, P. Muzzio, F. Pomerri; Padua/IT
(
[email protected])
Purpose: To analyse the progression curves of renal masses (RMs) in patients
with von Hippel-Lindau disease (VHL), and propose some changes in their
management.
Methods
and Materials: This retrospective study included 26 VHL patients
who underwent periodical magnetic resonance imaging (MRI) examinations as
follow-up for renal masses. Thirty-one of total 60 RMs (51.7%) were classified
as solid tumours (STs), and remaining 29 of 60 (48.3%) as complex cysts
(CCs). For each lesion, the volume was estimated at each MRI occurrence
using the ellipsoid approximation, and i ndividual growth curves were traced.
Variations in volume over time were analysed, and the mean growth rates
(MGRs) calculated. MGRs were used to compare STs and CCs.
Results
In cases for which several imaging occurrences were available, the
analysis of growth curves showed that solid tumours had an initial fast growth,
followed by slower growth, according to the Gompertzian model. Otherwise,
complex cysts showed some fluctuating progression curves, with spontaneous
regressions in volume. Medians of the MGRs were 1.28 cm
3/y for STs and
0.37 cm3/y for CCs, respectively, leading to statistically significant difference
(P=0.0023), and indicating a growing process substantially slower for CCs than
for STs.
Conclusion
This study showed that short-term MRI follow-up and multiple
lesion volume measurements in VHL patients, would allow a more accurate
estimation of the tumour growth curve, providing useful information to possibly
postpone the lesion treatment. Less aggressive approach seems to be
possible for complex cysts versus solid tumours.
10:30 - 12:00 Room F2
Breast
SS 102b
Elastography and breast interventions
Moderators:
A. Athanasiou; Paris/FR
R. Sinnatamby; Cambridge/UK
B-0071 10:30
Which ultrasound shear wave elastography parameter gives the highest
diagnostic accuracy for solid breast lesions?
K. Skerl, K. Thomson, P. Whelehan, S.J. Vinnicombe, A.J. Evans; Dundee/UK
(
[email protected])
Purpose: Shear wave elastography (SWE) shows promise in refining benign-
malignant differentiation of solid breast masses during ultrasound
examinations. However, published results show varying diagnostic
performances of the SWE features, and it is still unclear which of the three
numerical parameters obtained (maximum, mean and standard deviation of the
tissue elasticity measurements within a region of interest) gives optimal
diagnostic accuracy.
Methods
and Materials: The shear wave parameters of 1,152 solid breast
masses were recorded prospectively prior to histological examination. Four
images were obtained in two orthogonal planes using the Aixplorer device
(SuperSonic Imagine).The values (generated using an ROI of 2 mm placed
over the area of highest Emean) from the four images were averaged.
Suggested thresholds from the literature (50 kPa for Emean, 80 kPa for Emax
and 7 for SD) were used to calculate the diagnostic accuracy. Differences were
evaluated using the chi-squared test.
Results
The masses studied consisted of 791 cancers and 361 benign
lesions. 63% of lesions were symptomatic (mean US size 20 mm) while 37%
were screen detected (mean US size 13 mm). The diagnostic accuracy (the
combination of sensitivity and specificity for cancer) for Emean was 84%. This
was significantly higher than the diagnostic accuracy using EMax (81%,
p=0.03) or SD (79%, p=0.001).
Conclusion
In this study the Emean measurements gave the highest
diagnostic accuracy of the three shear wave parameters known to be of
diagnostic value.
Author Disclosures:
K. Skerl: Research/Grant Support; I am a PhD student partly founded by
SuperSonic Imagine.
B-0072 10:39
Shearwave elastography improves the diagnostic accuracy in the
characterisation of benign and malignant breast lesions
W. Ng, K. Rahmat, F. Fadzli, C. Westerhout, A. Vijayananthan, Y. Abdul Aziz;
Kuala Lumpur/MY (
[email protected])
Purpose: Shear wave (SW) elastography is an ultrasound technique based on
tissue stiffness and provides quantitati ve information of breast lesions
elasticity. We aim to investigate the diagnostic value of breast SW
elastography in differentiating between benign and malignant lesions.
Methods
and Materials: One hundred and sixty-six lesions in a total of 161
patients were examined by conventional ultrasound and SW elastography
using Aixplorer® (SuperSonic Imagine, France). The lesions were assessed
using B-mode and SW parameters were recorded (mean, maximum, and
minimum elasticity of stiffe st portion of lesion and surrounding tissue; lesion-to-
fat elasticity ratio; size ratio of SW elastographic-to-B-mode lesion). SW
elastography measurements were correlated with histopathology of core or
surgical biopsy diagnosis.
Results
Final analysis comprised of 92 benign and 74 malignant lesions. The
maximum stiffness (Emax) with a cut-off point based on ROC curve of 58.0
kPa provided sensitivity of 90.0%, specific ity of 91.3%, positive predictive value
of 97.3%, negative predictive value of 91.3% and accuracy of 94%. Applying a
cut-off point of 42.0 kPa for SW elastographic mean stiffness (Emean),
generated sensitivity of 86.7%, specificity of 97.6%. For SW elastographic ratio
(E ratio), the value of 2.2 was found to be optimal, yielding sensitivity of 72%
and specificity of 97%.
Conclusion
Shearwave elastography provid es highly specific and sensitive
quantitative values which is beneficial in the characterisation of breast lesions.
Our results showed that Emax is the most accurate parameter for
differentiating benign from malignant lesions.
B-0074 10:48
Can we reduce the number of MR-guided biopsies? Application of an
algorithm that increases specificity
P.A.T. Baltzer, K. Pinker-Domenig, M. Bernathova, T.H. Helbich; Vienna/AT
Purpose: MR-guided biopsy is a useful but expensive technique which is
routinely performed on suspicious breast lesions which are apparent only on
MRI. Our aim was to apply a classificati on algorithm assess its efficacy in
predicting benign and malignant disease in lesions.
Methods
and Materials: This IRB-approved retrospective study investigated
385 consecutive patients (mean age 51.6, SD 12.8) undergoing MR-guided
vacuum biopsy of suspicious (BI-RADS 4) breast lesions only visible on MRI.
An experienced radiologist blinded to histological diagnoses applied a
previously published classification algorithm (Eur Radiol 23 (8):2051-60) based
on five morphologic and dynamic criteria to all lesions. ROC analysis was
performed in order to measure diagnostic performance for lesion
differentiation.
Results
Of 399 biopsied lesions, 79 (19.8%) were malignant. The
classification algorithm show ed an accuracy of 87.2% (P < 0.001). 282 of 399
(70.7%) lesions could be classified as benign with a negative predictive value
of 94.3% (266/282). In 89 of 399 lesions (22.3%), a benign histopathologic
Result
could be predicted with 100% accuracy. In the remaining 117 of 399
lesions, malignancy could be predicted wi th a positive predictive value of 36.2-
100% (average 53.8%).
Conclusion
Application of a simple classi fication algorithm proved its
diagnostic use when applied to BI-RADs 4 lesions only visible on MRI.
According to our results, at least 22.3% of all biopsies could be omitted.
B-0075 10:57
Ultrasound guided HIFU treatment of breast fibroadenoma
M.M. Abehsera
1, J.-N. Gugliemina1, J.I. Stoinov2, E. Poncelet3, N. Laurent3,
L. Boulanger4, A. Dana1, C. Tibi1, R.D. Kovatcheva2; 1Neuilly/FR, 2Sofia/BG,
3Valenciennes/FR, 4Lille/FR (
[email protected])
Purpose: The objective of our clinical study is to demonstrate the feasibility,
the safety and the efficacy of ultrasound-guided HIFU (USg-HIFU) in the
treatment of the breast fibroadenoma.
Methods
and Materials: To date, 51 breast FA in 42 patients has been
treated by HIFU in 4 European sites. Patients mean age was 32 [16-52]. All
FAs were confirmed by histology analysis after a core needle biopsy. The HIFU
treatment was performed as an outpatient procedure using neurolept
analgesia. The mean baseline volume of the FA was 3.89 cc [0.34 -
19.7 cc].To evaluate potential acute effects, the first follow-up examination was
performed at 7 days after HIFU, and the next follow-up visits were performed
with an Echo Doppler every month from M1 to M6, and from M9 to M24.
S152
B A C D E F G
Thursday
Results
The average treatment time was around 1h12 [0h26-2h33]. A 27
years old patient who became pregnant one month after the HIFU treatment,
showed a reduction of volume of 73% at M12 despite hormonal impregnation
due to pregnancy. One patient reviewed at M 11 had a volume reduction of
93%. The Mean Volume Reduction was up to 77.6 % at M24.
Conclusion
HIFU treatment is a non-invasive method, well tolerated by
patients. For all patients, the volume of the FA declined progressively.
Preliminary results are encouraging and show that HIFU could be an
interesting alternative treatment.
B-0076 11:06
Non-biopsy or follow-up of presumed fibroadenomas in patients under 30
years of age: is it safe? Four years experience in a single unit and review
of European practice
K. Taylor, H. Vandersluis, P. Britton, M.G. Wallis; Cambridge/UK
(
[email protected])
Purpose: In women under 30 years; fibroadenomas (FA) are the commonest
BIRADS 3 lesion and breast cancer is infrequent. On the basis of a 9-year
audit in 2009, we implemented strict imaging and clinical criteria such that
women< 30 with presumed FAs could safely be discharged without needle
sampling or follow-up. Four years after protocol implementation, we report on
its accuracy, effect on biopsy workload and potential for influencing European
practice.
Methods
and Materials: All women < 30 attending the breast unit between
1.2.09 and 31.1.13 were retrospectively identified from our clinical database;
their management audited and followed up to 31.6.13. In addition, a survey
assessing European practice was completed by 32 centres from 19 countries.
Results
1571 women< 30 attended the breast unit. 6 aged 25-29 (BIRADS 4)
were diagnosed with breast cancer. Of 332 women scored BIRADS3; 266 (84
aged 25-29) met the non-biopsy criteria and were discharged, 66 were outside
the criteria and underwent biopsy (54 FAs, 7 phyllodes tumours, 1 cancer). 14
women re-attended with increased lesion size, none biopsied but 5 excised at
the patients request. The protocol reduced biopsies by 78% in women 20 and
by 72% in women aged 25-29. No cancers developed in discharged patients,
median follow-up 2.3 yrs (range 0.4-4.4). The European survey indicates 29%
of respondents routinely sample FAs in women 20, 55% in women 25. Of non
UK respondents, 84% follow-up FAs regardless of patient age, 65% regardless
of biopsy history.
Conclusion
Our non-biopsy protocol appears safe, reduces biopsy workload
and justifies a discharge policy.
B-0077 11:15
Sonographically guided biopsy with 14 Gauge vacuum assisted probe:
false-negative and underestimation rate
V. Girardi, G. Carbognin; Brescia/IT (
[email protected])
Purpose: To determine the diagnostic accuracy of US-guided 14-gauge
vacuum assisted biopsy for breast lesions.
Methods
and Materials: Seven hundred forty-five cases of sonographically
core needle biopsies using a 14-gauge vacuum assisted probe were performed
consecutively. We assessed the false-negative rate and the underestimation
rate. The false-negative rate was defined as pathologically proved cancer for
which US-guided biopsy results were benign findings. The underestimation
rate was defined as an upgrade of a high-risk lesion (atypical ductal
hyperplasia (ADH), lobular carcinoma in situ, intraductal papilloma and
papilloma with atypia, radial scar, phyllodes tumor) or ductal carcinoma in situ
(DCIS) at US-guided biopsy to malignancy at surgery. The gold standard were
surgical examination or stability during clinical and imaging follow-up ( > 12
months).
Results
False-negative finding was founded in 1 (1.34‰) of 745 cases and
the false-negative rate was 6.71‰ (1 of 149 malignancies). In 3 (3.1%) of 96
high-risk lesions there was upgraded to malignancy at surgical excision (1
invasive lobular carcinoma, 1 DCIS, 1 DCIS with microinvasion). At Vacuum
Assisted Biopsy, these lesions were ADH, papillary lesions and papilloma with
atypia. In 3 (33.3%) of 9 cases with a DCIS lesion at US-guided 14-gauge
VAB, surgical excision showed invasive carcinoma (2 invasive carcinomas, 1
DCIS with microinvasion).
Conclusion
Use of 14-gauge vacuum-assisted demonstrated good accuracy
for false-negative findings (1.34‰). Lesion underestimation was more likely
when US-guided 14-Gauge Vacuum Assisted Biopsy revealed DCIS (33.3%)
rather than high-risk lesion (3.1%).
B-0078
11:24
Vacuum-assisted breast biopsy using computer-aided 3 T-MRI guidance:
a preliminary experience
I. Baglio, L. Camera, G. Barbazeni, C. Cavedon, Q. Piubello, S. Montemezzi;
Verona/IT
Purpose: To test the feasibility of MRI-guided vacuum-assisted breast biopsy
for diagnosis of suspicious breast lesions detected at 3.0 Tesla.
Methods
and Materials: Between October 2011 and June 2013, 45
suspicious breast lesions detected with a 3.0 T MR scanner underwent a
computer-aided MRI-guided (Dynacad) vacuum-assisted biopsy with post-and
pillar technique. All lesions biopsied were classified as BI-RADS 4 or 5. A
seven-channel breast array coil equipped for biopsy and a dedicated
diagnostic workstation were used for the localisation of the target lesion. After
calculating the localisation co-ordinates on the dedicated workstation, a MR-
compatible needle (11G or 8G) inserted in the coaxial cannula was placed in
the planned position. Post-procedure MRI scans were used to confirm the
correct localisation of a marker left in the site of the biopsy.
Results
The mean lesion size was 13.5 mm (range: 5-32 mm). On
histopathological examination, 13 were malignant (8 DCIS, 1 mixed carcinoma,
1 tubular carcinoma, 1 invasive lobular carcinoma, 2 invasive ductal
carcinoma); 9 were high-risk lesions (3 papilloma, 1 LIN 2, 1 LIN, 1 ADH, 2 DIN
1b, 1 radial scar) and 23 were benign lesions. All malignant and high-risk
lesions were sent to surgery (wide local excision or mastectomy), benign
lesions were sent to follow-up (6-12 months). Examination of surgical
specimens confirmed the results of vacuum-assisted biopsy in all malignant
lesions.
Conclusion
Our preliminary experience revealed that 3-T MRI-guided
vacuum-assisted biopsy is a safe and effective interventional method that
enables accurate biopsy of lesions, especially for small lesions.
B-0079 11:33
Is galactography still state of the art in patients with nipple discharge?
An online survey among german breast care centers and a review of the
literature
K. Scheurlen, A. Schnitzer, J. Krammer, C. Kaiser, S.O. Schönberg,
K. Wasser; Mannheim/DE (
[email protected])
Purpose: Since methods such as high-resolution ultrasound (US) and MR-
Mammography (MRM) have been established in modern breast imaging the
mandatory usage of galactography in patients with nipple discharge is worth
questioning.
Methods
and Materials: An anonymous online survey was carried out
nationwide, opened to 342 radiologic units of certified German centers. 2) A
literature search was performed in PubMed and Cochrane for studies reporting
on the diagnostic value of galactography, US and MRM.
Results
1) 177 units (52%) participated. 13% generally do not provide
galactographies. 57% conduct a maximum of 5-10 galactographies per year,
18% 11-20, 8% 21-50 and 5% 51-100. Only 4% use galactography initially.
85% give fist priority to US, then followed by galactography (53%) or MRM
(32%) in a stepwise diagnosis. 2) A total of 19 studies were found, 14 with
Results
on galactography, 10 on ultrasoundand 5 on MRM. Almost all studies
are retrospective. Due to a very variable number of cases and differing
inclusion criteria the studies are only comparable to a limited extent and the
Results
on the diagnostic values show a very wide range.
Conclusion
Today galactography is a rarely used method for the vast majority
among german breast care centers. Thus, galactography is no longer seen as
state of the art within a modern multimodal imaging concept. Furthermore,
there is no evidence in the literature for a mandatory usage of galactography.
Overall, galactography, US and MRM show a weak evidence and the
superiority of one method cannot be derived from the literature.
B-0080 11:42
Fast migration of breast biopsy marker placement during stereotactic
core needle biopsy
K. Buch, M.M. Qureshi, A. Jain, A.E. Hirsch, C. Jaffe, D. Georgian-Smith,
N. Hines, N.B. Bloch; Boston, MA/US (
[email protected])
Purpose: The accurate placement of stereotactic biopsy clips is not only
important for localising breast lesions undergoing surgical excision, but also
defining the biopsy sites on subsequent mammographic follow-up in lesions
not requiring excision. The purpose of this study was to examine marker
migration on follow-up biopsy mammograms.
Methods
and Materials: A total of 275 SecurMark (Hologic, Bedford, MA)
stereotactic biopsy clips were placed in 265 patients undergoing uncomplicated
stereotactic biopsies using a 9-gauge vacuum-assisted device from August
2010 to July 2013. Follow-up mammograms on lumpectomy specimens that
confirmed marker placement were used to measure the amount of marker
migration. Patients with a marker migration of greater than 1 cm were
S153
B A C D E F G
Thursday
recorded. Descriptive statistics were ca lculated and comparisons between two
groups were made with the unpaired t-test
Results
Of the 275 stereotactic biopsy clips, 35 (12.7%) clips had migrated at
least 1 cm from the intended biopsy cavity. The range of marker migration was
1-6 cm with a mean ( ± standard deviation) marker migration of 2.40 ± 1.25 cm.
Of the 35 migrated biopsy markers, 9 (25.7%) had a migration of 3.5 cm or
greater. There was no difference in the amount of migration in the right
(2.25 ± 1.02 cm) versus left (2.53 ± 1.42 cm) breast, p=0.513
Conclusion
In this patient cohort, approximately 13% of markers had
migrated at least 1 cm from the original biopsy cavity. Marker migration may
lead to diminished accuracy of lesi on location on radiographic follow-up.
Further study is warranted to assess clinical correlations.
10:30 - 12:00 Room G/H
Genitourinary
SS 107
Prostate cancer: diagnosis and PIRADS
scoring
Moderators:
O. Nikolic; Novi Sad/RS
M.M. Otero-García; Vigo/ES
B-0081 10:30
A novel 68Ga-PSMA PET ligand in patients with biochemical recurrence
of prostate cancer using PET/CT and PET/MR imaging
M. Eiber, T. Maurer, A. Beer, M. Souvatzoglou, K. Holzapfel, H.-J. Wester,
E.J. Rummeny, M. Schwaiger; Munich/DE (
[email protected])
Purpose: Prostate-specific membrane antigen (PSMA) is a cell surface protein
with high expression in prostate cancer. Recently, Glu-NH-CO-NH-Lys-(Ahx)-
[(68)Ga (HBED-CC)] as a new 68Ga-labelled PSMA ligand (68Ga-PMSA) has
been developed. Preliminary data show a high and specific uptake prostate
cancer. The aim of this study was to investigate the detection rate of 68Ga-
PSMA PET/CT and PET/MR imaging patients with a biochemical recurrence.
Methods
and Materials: 107 patients (mean age 63.8 ±7.9) were included in
the analysis. Median PSA level was 1.9 ng/ml (range 0.2-45 ng/ml). After
injection of 122 ±17 MBq 68Ga-PSMA, 62 patients underwent contrast-
enhanced PET/CT and 45 fully diagnostic PET/MR (including multiparametric
prostate MR). Images were reviewed by one nuclear medicine physician and
one radiologist. Findings were rated as suspicious or highly suggestive for
recurrent prostate cancer.
Results
92 of 107 (85.9%) patients showed a pathological 68Ga-PSMA
uptake. For PET/CT and PET/MR, respectively, the detection rates were 97.6%
(40/41) and 100.0% (13/13) for PSA value 2 ng/ml, 91.7% (11/12) and 88.9%
(8/9) for a PSA value 2-3 ng/ml, 66.6% (6/9) and 56.6% (13/23) for a PSA
value < 1 ng/ml. Especially in cases with PSA values < 1 ng/ml, the diagnostic
certainty was considerably higher when combining 68Ga-PSMA with
multiparametric MR compared to PET/CT. Findings were rated as suspicious
vs. highly suggestive in 5/9 vs. 1/9 patients in PET/CT and 2/23 vs. 11/23
patients in PET/MR.
Conclusion
68Ga-PSMA PET imaging shows a higher of positive findings for
patients with recurrent prostate cancer than reported for other tracers
especially at low PSA values. PET/MR should be preferred in patients with
PSA < 1 ng/ml as multiparametric MR provides additional information
increasing the diagnostic certainty.
B-0082 10:39
Non-Gaussian water diffusion kurtosis imaging of prostate cancer
S. Suo, X. Chen, L. Wu, Y. Fan, Q. Yao, J. Xu; Shanghai/CN
(
[email protected])
Purpose: To assess the non-Gaussian water diffusion properties of prostate
cancer (PCa) and to determine the diagnostic performance of diffusion kurtosis
(DK) model for distinguishing PCa and benign tissues within the peripheral
zone (PZ).
Methods
and Materials: Nineteen male patients (mean age 68 years, range
51-81 years; mean preoperative PSA level 16.9 ng/ml, range 3.26-115 ng/ml;
mean postoperative Gleason score 7, range 6-9) who were pathologically
confirmed with prostate carcinoma were enrolled in this study. All patients
underwent a prostatic MR protocol on a 3 Tesla MR scanner using a body
phased-array coil including T1-weighted imaging, T2-weighted imaging and
axial multi-b DW imaging (b-values= 0, 500, 800, 1200, 1500, 2000 sec/mm2).
Region of interests (ROIs) were placed on prostate cancer according to
pathological findings and benign tissues within PZ for comparison. K, D and
ADC values of the ROIs were calculated. Differences between K values of
benign PZ and PCa were assessed using paired t-tests. Correlation between
parameters D and K in PCa was assessed using Pearson's correlation
coefficient.
Results
ADC and D were significantly (p < 0.001) lower in PCa
(0.79±0.14 8m
2/ms and 1.56 ±0.23 8m2/ms, respectively) than in benign PZ
(1.23±0.19 8m2/ms and 2.54 ±0.24 8m2/ms, respectively). K was significantly
(p < 0.001) greater in PCa (0.96 ±0.20) than in benign PZ (0.59 ±0.08). The
correlation between parameters D and K in PCa was strongly negative
(Pearson correlation coefficient = -0.7291; p < 0.001).
Conclusion
The DK model appears to provide more parameters for PCa
detection. K potentially offers a new metric for assessment of PCa.
B-0083 10:48
MRI features of chronic prostatitis and differentiation from co-existant
prostate cancer
K. Buch, A. Jain, M.M. Qureshi, C. Jaffe, D. Wang, R. Babayan, J. Henderson,
C. Andry, N.B. Bloch; Boston, MA/US (
[email protected])
Purpose: Chronic prostatitis is a common histopathologic finding on total
prostatectomy specimens; however, imaging features are not well established.
Prior reports describe significant overlap in perfusion characteristics between
prostate cancer and chronic prostatitis with no difference in perfusion between
low-grade cancer and chronic prostatitis. The purpose of this study was to
differentiate T2 and enhancement characte ristics of chronic prostatitis from
cancer using contrast-enhanced MRI (CE-MRI).
Methods
and Materials: Following IRB approval, 55 prostate pre-operative
CE-MRIs were performed from January 2012 to July 2013 on a 1.5-T scanner
in consecutive prostate cancer patients who underwent prostatectomy. MRI
findings suggestive of chronic prostatitis were compared to prostatectomy
specimens.
Results
Imaging features most suggestive of chronic prostatitis include late-
enhancing pseudoseptations with fine, linear striations in a centrifugal pattern
irrespective of rapid wash-in within area s with preserved pseudoseptations on
dynamic CE-MRI. Of 55 patients, 47 had chronic prostatitis by histopathologic
criteria; 50 had MRI findings suggestive of chronic prostatitis with 3 false
positives. These findings had a sensitivi ty of 100%, specificity of 62.5%, PPV
of 93.8%, and NPV of 100%.
Conclusion
The key distinction between chronic prostatitis and cancer is the
persistent enhancement of fine, centrifug al striations in chronic prostatitis
compared to nodular, confluent enhancement without preserved
pseudoseptations in cancer. CE-MRI has a high sensitivity, PPV, and NPV for
diagnosing coexistent chronic prostatitis in prostate cancer patients. These
distinctive imaging features are of high clinical value as they may decrease
over-estimation of prostate cancer size and lead to more accurate MRI staging
of prostate cancer.
B-0084 10:57
Role of multiparametric magnetic resonance imaging using T2-weighted,
diffusion-weighted and 4D perfusion contrast-enhanced MRI in prostate
cancer at 3 T
E. Karaarslan, D. Gürbüz, Ö.S. Ulus, Ö.B. Argun, A.R. Kural; Istanbul/TR
(
[email protected])
Purpose: We aim to emphasise the importance of a relatively new
multiparametric MR imaging method performed at 3 T using T2-weighted,
diffusion-weighted and 4D perfusion dynamic contrast-enhanced MR imaging
in diagnosing prostate cancer and de tecting biological characteristics of the
tumour.
Methods
and Materials: Multiparametric MR imaging findings of 21 patients,
with no previous treatment, diagnosed to potentially have prostate cancer due
to palpable prostatic nodules and/or elevated serum PSA levels (average of
10.26 ng/ml) are evaluated retrospectively. Multiparametric MR imaging
sequences were obtained using multi-channel pelvic phase array coil on 3 T
Siemens Skyra device. We performed statistical analysis to define the
relationship between multiparametric MR imaging parameters and
histopathological findings.
Results
87 foci were positive for pros tate cancer with histopathological
findings in 12 patients. Pairwise t-test results show that K-trans (ADC) values
are significantly higher (lower) in the tumour tissues compared to the normal
ones and regression analysis shows a significant relationship (p-value=0.016,
significance level=5%) between th e ratio of K-trans values of the tumour
tissues to that of normal tissues and the Gleason score. A unit increase in this
ratio contributes to an average increase of 0.25 in the Gleason score.
Conclusion
We conclude that the T2-weighted morphological imaging
method, when used together with functional MR imaging methods such as
diffusion-weighted and 4D perfusion dynamic contrast-enhanced MRI, is
effective in diagnosing prostate cancer. It also has the potential of providing
reliable information regarding biological characteristis of the tumour and the
prognosis of the patients.
S154
B A C D E F G
Thursday
B-0085 11:06
Prospective impact of the additional use of an endorectal coil for 3 T
prostate MRI on image quality and cancer detection rate
J. Otto, G. Thörmer, M. Reiss-Zimmermann, N. Garnov, L.-C. Horn, M. Do,
T. Kahn, M. Moche, H. Busse;
Leipzig/DE (
[email protected])
Purpose: To prospectively compare the impact of an additional endorectal
receive coil (ERC) on the quality of prostate MR images within the same
patients and to determine the corresponding rates for the detection of prostate
cancer (PCa).
Methods
and Materials: Prior to radical prostatectomy, 41 patients underwent
T2- and diffusion-weighted imaging at 3 T using surface coils only (SC) or in
combination with an ERC. Two blinded readers (A and B with 70 and 160
prostate readings, respectively) randomly evaluated all image data in two
separate sessions. Image quality scores for localisation and staging were rated
on a five-point scale (1: very poor, 2: poor, 3: moderate, 4: good, 5: very good).
Cancer-suspicious lesions were classified according to their PI-RADS (prostate
imaging reporting and data system) score (1-5). Standard of reference was
provided by whole-mount histopathologic section analysis.
Results
Mean scores of image quality with ERC were significantly (p < 0.001)
higher than those without. PI-RADS 3 was assigned in 62 (ERC) vs. 49 (SC)
cases (A) and 64 vs. 48 (B). Detection rates per lesion were similar for (A),
76% (47/62, ERC) vs. 78% (38/49, SC), and significantly (p < 0.05) higher for
(B), 88% (56/64) vs. 71% (34/48). Per patient, PCa was correctly identified in
88% (A) vs. 98% (B) of all ERC cases and in 78% (A) vs. 73% (B) without.
Conclusion
Diagnostic performance in terms of the number of cancer-
suspicious as well true cancer foci was high er when an additional ERC was
used for 3-T prostate MRI.
B-0086 11:15
Prostate cancer diagnosis using MR imaging: does PI-RADS better than
conventional methods?
W. Xia, X. Chen, H. Li; Zhengzhou/CN (
[email protected])
Purpose: To compare the value of prostate imaging reporting and data system
(PI-RADS) with conventional methods on diagnosing the prostate cancer.
Methods
and Materials: 166 patients (91 prostate cancers, 75 benign
prostatic lesions) with integrated clinical data were enrolled in the study. All
patients underwent 3.0 T MR prostate scanning, including T1WI, T2WI, DCE-
MRI, DWI and MRS sequences. First, two radiologists who analysed the
images in conventional methods, then PI-RADS method was used to analysis
T2WI, DCE-MRI, DWI and MRS. The accuracy, sensitivity and specificity were
calculated and compared.
Results
The accuracy, sensitivity and specificity using conventional methods
on diagnosing prostate cancer were 81.32% (135/166), 82.41% (75/91),
80.00% (60/75), respectively. ROC curve was used to analysis PI-RADS score,
area under the curve (AUC) was 0.91, the sensitivity and specificity were 88%
and 85% if taking 13 points as threshold. Taking 13 points as threshold,
amongst 91 prostatic cancer, 84.62% (77/91) PI-RADS score 13 points,
whilst amongst 75 benign lesions 13.33% (10/75) PI-RADS score 13 points.
The accuracy was 85.54 % (142/166).
Conclusion
Compared with conventional diagnostic methods, the application
of PI-RADS can improve the accuracy. Taking PI-RADS =13 points as
threshold to identify prostate cancer ha s higher sensitivity and specificity.
B-0087 11:24
Validation of MRI sequences for PI-RADS scoring based on targeted MR-
guided in-bore biopsy
L. Schimmöller
1, M. Quentin1, C. Arsov1, C. Buchbender1,
A. Seif Amir Hosseini2, R. Rabenalt1, P. Albers1, G. Antoch1, D. Blondin1;
1Düsseldorf/DE, 2Göttingen/DE (
[email protected])
Purpose: This study retrospectively validates the ESUR scoring system (PI-
RADS) in regard to the accuracy of the different MRI sequences at 3 T using
MR-guided in-bore prostate biopsies as the reference standard.
Methods
and Materials: 492 different lesions in 218 consecutive patients
(65.7 ± 7.9 years) with diagnostic 3 T prostate MRI consisting of T2-weighted,
diffusion-weighted, and dynamic contrast-enhanced imaging (T2WI, DWI,
DCE-MRI) were scored according to the PI-RADS score. Histology of all
lesions was obtained by targeted MR-guide d in-bore biopsy. Statistical analysis
including ROC analysis was completed on all data.
Results
In 159 lesions (98 patients) MR-guided biopsy was positive for
tumour (Gleason grade 6 or higher). ROC analysis for each MRI-sequence
leads to an area under the ROC curve (AUC) value of 0.683 for T2WI, 0.775
for DWI, and 0.704 for DCE-MRI. For a combination of two sequences, the
AUC was 0.789 for T2WI + DWI, and 0.751 for T2WI + PWI. All three MRI-
sequences together achieved an AUC value of 0.787 (T2w+DWI+DCE-MRI).
For clinical significant prostate cancer (Gleason grade 7b and higher), the AUC
value was 0.852 for T2WI + DWI, 0.839 for T2WI + PWI, and 0.72 for T2WI +
DWI + DCI-MRI.
Conclusion
The summed PI-RADS score of T2WI, DWI, and DCI-MRI
achieves the highest testing accuracy in our patient collective, especially in
patients with clinical significant prostate cancer. A usage of only two or less
MRI sequences leads to a lower AUC.
G. Antoch: Speaker; Siemens AG, Bayer AG, BTG Röntgen GmbH.
B-0088 11:33
Evaluation of multiparametric MRI PI-RADS scores for the detection of
prostate cancer
T. Durmus1, T. Franiel2, A. Maxeiner1, E. Kilic1, A. Huppertz1, B. Hamm1,
A.D.J. Baur1; 1Berlin/DE, 2Jena/DE (
[email protected])
Purpose: To evaluate the magnetic resonance prostate imaging-reporting and
data system (PI-RADS) for the detection of prostate cancer.
Methods
and Materials: 113 lesions of 55 patients who had undergone MRI-
guided biopsy of the prostate were retrospectively matched with the
corresponding images in previously acquired endorectal multiparametric MR
imaging (T2-TSE, DWI, and DCE-MRI) at 1.5 Tesla. Blinded to the results of
biopsy two readers evaluated each biopsied lesion according to the PI-RADS
scoring system. ROC analysis was performed for statistical analysis.
Results
PI-RADS scores of DCE-MRI revealed a lower AUC (0.76) compared
to T2 (0.88; p=0.0619) and DWI (0.93; p=0.0043). Sum scores of T2, DWI,
DCE-MRI and of T2 and DWI, only, yielded an AUC of 0.93 and 0.95,
respectively. In central gland lesions T2 showed a numerically higher AUC
compared to DWI (0.98 and 0.95) whilst in peripheral zone lesions DWI was
significantly superior (AUC of 0.93 and 0.73; p=0.041). An approach assigning
the PI-RADS score of T2 to central gland lesions and the score of DWI to
peripheral zone lesions yielded the highest AUC (0.96) compared to any
sequence alone and combined sum scores.
Conclusion
The PI-RADS scoring system for the detection of PCa has a good
diagnostic performance. However, scores of DCE-MRI seem to add significant
value when evaluated according to the recommended criteria. Assigning the
score of T2 to central gland lesions and of DWI to peripheral zone lesions
might be sufficient for stratification of patients for further diagnostic workup.
Author Disclosures:
A. Huppertz: Employee; Siemens AG. B. Hamm: Board Member; Deutsche
Röntgengesellschaft, European Congress of Radiology, European Society of
Uroradiology, ESMRMB, European School of Radiology, Deutsche
Forschungs-gemeinschaft. Consultant; Bayer Schering Pharma, Toshiba.
Other; Abbott, Actelion, Bayer Schering Pharma, Bayer Vital, BRACCO Group,
Bristol-Myers Squibb, Charité research organisation GmbH, Deutsche
Krebshilfe, Dt. Stiftung für Herz- forschung, Essex Pharma, EU Programmes,
Fibrex Medical Inc., Focused Ultrasound Surgery Foundation, Fraunhofer
Gesellschaft, Guerbet, INC Research, InSightec Ltd., IPSEN Pharma, Kendle/
MorphoSys AG, Lilly GmbH, Lundbeck GmbH, MeVis Medical Solutions AG,
Nexus Oncology, Novartis, Parexel CRO Service, Perceptive, Pfizer GmbH,
Philipps, sanofis-aventis S.A, Siemens, Spectranetics GmbH, Terumo Medical
Corporation, TNS Healthcare GMbH, Toshiba, UCB Pharma, Wyeth Pharma,
Zukunftsfond Berlin (TSB).
B-0089 11:42
ESUR scoring system for prostate cancer detection: how to derive the
overall PI-RADS score from different single modality scores?
D. Junker, F. Aigner, J. Bektic, W. Horninger, W.R. Jaschke; Innsbruck/AT
(
[email protected])
Purpose: To evaluate different ways to derive the overall PI-RADS score (1-5)
from different single modality scores.
Methods
and Materials: Retrospective: The 3 T multiparametric MRI (mpMRI)
datasets of 143 consecutive patients were evaluated. Diffusion-weighted
imaging, T2-weighted imaging and dynamic contrast-enhanced imaging were
performed. 73 patients underwent mpMRI-ultrasound image fusion guided re-
biopsy. After scoring these 3 PI-RADS single modalities (1-5), a summation
score (3-15) was calculated and 3 different ways to generate an overall PI-
RADS score were compared: One approach, which generates the overall PI-
RADS from the radiologist's impression after evaluating the single modalities,
was compared to different approaches, which derive the overall PI-RADS by
division from the summation score.
Results
For calculation of the overall PI-RADS score, a mathematical
approach derived from the summation score, as presented by Roethke et al.,
showed the highest reliability: The threshold of 10 (PI-RADS 4) showed high
sensitivity (90%) and specificity (62%) for tumour incidence and that of 13 (PI-
RADS 5) high sensitivity (80%) and specificity (86%) for the presence of high
risk disease (gleason 4+3). Overall, the single and summation scores
correlated well with tumour incidence (AuC of 0.86, 95% CI 0.78 to 0.94) and
grading (AuC 0.84, 95% CI 0.68 to 0.99).
S155
B A C D E F G
Thursday
Conclusion
A mathematical approach that derives the Overall PI-RADS score
(1-5) from the summation score proved to be reliable. Therefore our data
suggest a threshold of 10 for PI-RADS 4 and 13 for PI-RADS 5.
B-0090 11:51
Interobserver agreement of the PI-RADS score for prostate cancer
diagnosis on multiparametric MRI
E.H.J. Hamoen
1, L.C. Thompson2, F. Witjes1, M.M. Rovers1, J.O. Barentsz1;
1Nijmegen/NL, 2Brisbane/AU (
[email protected])
Purpose: To study the interobserver agreement of the proposed Prostate
Imaging Reporting and Data System (PI-RADS) of the ESUR for structured
reporting of mp-MRI of the prostate.
Methods
and Materials: We conducted an institutional review board-approved
single cohort prospective clinical trial. We included 223 men who were
suspected of having prostate cancer because of an elevated PSA or abnormal
digital rectal examination, without prior transrectal ultrasound-guided biopsies
(TRUSGB) of the prostate. All men underwent a 3 T mp-MRI, which included
T2-weighted (T2WI), diffusion weighted imaging (DWI), and dynamic contrast
enhanced (DCE) MRI. Histology of all lesions was obtained by in-bore MR-
guided biopsy followed by standard TRUSGB in MR-positive men, or only
standard TRUSGB in MR-negative men. All MRI sequences were co-read
independently by 2 investigators. Any discrepancies were resolved by
consensus. Inter-observer variability was calculated using percentages of
agreement and intraclass correlation coefficients (ICCs) based on a per-patient
analysis.
Results
The overall percentage of agreement for the different PI-RADS
categories was 75.8% (169/223). When cl assified to consequence (i.e, whether
to perform a biopsy or not; PI-RADS 1-2 vs. PI-RADS 3-5), the percentage of
agreement was 91.9% (205/223). Inter-reader agreement was good with an
ICC of 0.89 (95% CI, 0.86-0.92). ICCs of the different modalities were
moderate, varying from 0.65 (95% CI, 0.56-0.72) for DCE and 0.66 (95% CI,
0.58-0.72) for DWI to 0.67 (95% CI, 0.60-0.74) for T2WI.
Conclusion
The ESUR PI-RADS score shows good to moderate inter-
observer agreement and enables standardised evaluation of mp-MRI for
prostate cancer detection.
10:30 - 12:00 Room I/K
Neuro
SS 111
Novel applications of MRI techniques
Moderators:
I.N. Pronin; Moscow/RU
W. Van Hecke; Antwerp/BE
B-0091 10:30
First-in-human trial of glutamine PET metabolic imaging: preliminary
Results
in glioma
C. Pressl
1, M. Dunphy2, I. Mellinghoff2, A. Omuro2, S. Venneti2, J. Lewis2,
H. Kung3, C. Thompson2; 1Vienna/AT, 2New York, NY/US, 3Philadelphia,
PA/US (
[email protected])
Purpose: To study the pharmacokinetics, metabolism, biodistribution and
radiation dosimetry of [F-18] 4-L-Fluoroglutamine ( 2S, 4R ), a radiolabelled
glutamine analogue, in glioma patients.
Methods
and Materials: IRB-approved trial protocol and US FDA-approved
exploratory IND. All patients provided signed informed consent. Main eligibility
criteria: > 21 years; tumour evident on clinical imaging; serum liver and renal
indices within specified range; no diabe tic medications. Patients fasted 8
hours. 222 MBq Fluoroglutamine tracer dose ( < 100 g) injected peripheral
IV. PET scans 0, 1, and 3h post-injection. Se rial blood sampling for activity and
metabolite assays. MIRD formalism and OLINDA software used for dosimetry
analyses of PET-derived and blood time-activity data.
Results
5 glioma patients to-date, including 5 low-grade tumors and 1
transformed high-grade tumour. High-grade glioma evident on Fluoroglutamine
PET with rapid, sustained tumour fluoroglutamine concentration. All low-grade
glioma PET-negative. Dosimetry favourable. No adverse events due to
fluoroglutamine tracer.
Conclusion
This is the first human trial of a glutamine-analogue imaging
agent to our knowledge. Our results demonstrate the feasibility of detecting
high-grade glioma in human subjects by PET imaging with [F-18] 4-L-
Fluoroglutamine (2S, 4R) and encourage testing of Fluoroglutamine PET as a
much-needed non-invasive biomarker for distinguishing aggressive high-grade
glioma from benign low-grade glioma.
B-0092 10:39
Motor function recovery prediction in patients with acute ischemic stroke
using diffusion tensor imaging
T. Popova, R. Konovalov, E. Seliverstova, M. Krotenkova, M. Maksimova;
Moscow/RU (
[email protected])
Purpose: Define possibility of diffusion tensor imaging (DTI) for assessing
corticospinal tracts (CST) to predict functi onal outcomes in patients with acute
isChemic stroke (IS).
Methods
and Materials: 47 patients (19 women, mean age 61) with primary
hemispheric IS were examined at 1, 14, 21 days since stroke onset. Fractional
anisotropy (FA) of CST was measured on two levels in both hemispheres:
posterior limb of internal capsule (PLIC) and cerebral peduncle (CP). Patients'
neurological status was assessed using NIHSS and mRS on the 1 st and 2 1 st
days and BI on the 2 1st day.
Results
Patients were divided in two groups: with satisfactory (group A, n=22)
and unsatisfactory (group B, n=25) outcomes of motor function recovery by the
end of acute period of IS. Following values of CST FA in ipsilateral side in PLIC
in group B were achieved: 1 st day-0.708, 14 th day-0.485, 2 1 st day-0.41.
Following values of CST FA in ipsilateral side in CP in group B were achieved:
1st day-0.746, 14th day-0.554, 2 1st day-0.473. Thereby, significant decrease of
CST FA was determined in group B in PLIC and CP on the 14 th and 2 1st days
(Mann-Whitney Test B< 0.05).
Conclusion
DTI allows to assess changes in conduction tracts beyond the IS
zone during acute period of IS. Signific ant alterations of CST are identified
using DTI on the 14 th day from onset in patients with unsatisfactory recovery of
motor function. Thereby, DTI can be applied for predicting of motor function
recovery in patients with acute IS.
B-0093 10:48
MR spectroscopy and FLT-PET: voxel-by-voxel comparison differentiates
tumorous tissue in high-grade glioma
J. Keller, J. Votrubová, I. Latnerová, F. Jír &, J. Kukal, J. Vymazal; Praha/CZ
(
[email protected])
Purpose: Aim of study was to evaluate the diagnostic accuracy of MR
spectroscopy (MRS) and 18 F-fluorothymidine-PET (FLT) in high-grade-
gliomas.
Methods
and Materials: Twelve patients underwent FLT-PET, MRI and MRS
on 1.5 T (2D chemical shift imaging (CSI), voxel 10x10 mm, slice thickness
15 mm, matrix 16x16 interpolated to 32x32, covering enhancing part of tumour
and healthy tissue, analysed using jSipro with LCModel). Combination of
glycerophosphocholine+phosphocholine (GPC+Pch), Creatine, Lactate and N-
acetylaspartate (NAA) concentrations were analysed, excluding values with
errors over 50%. After FLT-PET to CSI coregistration, mean uptake in each
CSI voxel was stored. Tumorous/normal tissue was segmented in contrast-
enhanced transversal T1-weighted images, values were normalised to the
mean of healthy tissue of each patient. Equality of median values in
tumorous/normal tissue was tested with Wilcoxon-Mann-Whitney test,
dependency of mean value of FLT on given descriptor was assessed by
Spearman correlation coefficient, both on significance level of 0.05.
Results
Comparing tumour and healthy tiss ue, mean FLT is significantly
higher in the tumour (p=3.718e-004). The ratios of NAA over
GPC+Pch (Wilcoxon p=4.119e-020/Spearman,rho=-0.36,p=2.133e-008) and
Creatine over GPC+PCh (p=7.904e-023/rho=-0.35,p=7.327e-008) significantly
differ, being higher in tumour and correlate with FLT. The same results were
obtained for NAA/Creatine (p=1.64e-017/rho=0.37,p=1.272e-008). GPC+PCh
is higher in tumor tissue (p=4.734e-009). On contrary, GPC+Pch/Lactate ratio
is lower in the tumour (p=1.334e-002).
Conclusion
To the best of our knowledge, we present the first voxel-based
technique for comparison of FLT-PET and MRS. Both FLT (mean value in the
volumes of MRS voxels) and MRS (GPC+Pch/NAA,
GPC+Pch/Creatine,Creatine/NAA,GPC+PCh and GPC+PCh/lactate)
differentiate tumour and healthy tissue. Supported by IGA MZCR
NT11328,NT12094/2011.00023001IKEM,PRVOUK P34.
B-0094 10:57
Microstructural brain tissue damage in metabolic syndrome
M. Sala, A. de Roos, A. van den Berg, I. Altmann-Schneider, E. Slagboom,
R. Westendorp, M. van Buchem, A. de Craen, J. van der Grond; Leiden/NL
(
[email protected])
Purpose: We investigate the association between metabolic syndrome risk
factors and brain tissue integrity, as assessed by magnetic resonance imaging.
Methods
and Materials: From the Leiden Longevity Study, which is a
community-based study of long-lived subjects, their offspring and partners
thereof, 130 subjects (61 men, mean age 66 years) were included. A metabolic
syndrome score was computed by summing the individual number of
components according to the Adult Treatment Panel III criteria. We performed
linear and logistic regression analysis and used standardised 2 values to
S156
B A C D E F G
Thursday
assess the association between metabolic syndrome and brain macrostructure
(brain volume and white matter lesion load, lacunar infarcts, and cerebral
microbleeds) and microstructure [mean magnetisation transfer ratio (MTR),
MTR histogram peak height, fractional ani sotropy, and mean diffusivity (MD)].
Linear and stepwise regression analysis was performed to identify the
individual contribution of one metabolic syndrome parameter adjusting for the
four other parameters. Models were adjusted for age, gender, and relation to
long-lived family.
Results
Brain macrostructure was not associated with metabolic syndrome. In
contrast, metabolic syndrome was associated with decreased gray (p=0.001)
and white matter peak height (p=0.002) and increased gray matter MD
(p=0.01). Serum HDLC ( 2=0.22, p=0.012), triglycerides ( 2=-0.25, p=0.002),
BMI (2=-0.2, p=0.014), and diastolic blood pressure ( 2=-0.17, p=0.047 and 2=-
0.23, p=0.009 for gray and white matter, respectively) were independent
factors in these changes in brain microstructure.
Conclusion
In early manifest metabolic syndrome, brain tissue decline can be
detected. Serum HDL cholesterol, trigly cerides, BMI, and diastolic blood
pressure were independent factors in brain tissue integrity.
B-0095 11:06
Experimental study on correlation of histopathological changes and
evaluation of MRI in rat spinal injury
E.-J. Lin; Huangpu/CN (
[email protected])
Purpose: To confirm how the impairments of neural functions and
histopathological changes in spinal cord are correlated to the FA value and
ADC value assessed by MRI.
Methods
and Materials: 48 SD rats were randomly assigned to the sham-
operated group and the model group. Animals in the model group were given a
surgery to expose the spinal cord and an absorbent polyurethane chip was
implanted between cervical laminae and cervical vertebral plate, both groups
were subdivided into four groups receiving different timing of injury: 4 h, 24 h,
72 h, 1 w, ADC and FA value were measure for data analysis, rats were killed
to histological assessment after BBB scoring and MRI scan. Number of motor
neurons in the anterior horn of cervical cord in HE-stained sections and the
fibre density in the posterior funiculus of cervical cord in LFB-stained sections
were measured. The statistical analyses of data were performed by one-way
ANOVA and Person correlation analysis.
Results
The correlation analysis demonstrated that the neuron number in the
anterior horn of cervical cord was positively correlated to the FA value (0.772)
while it was negatively correlated to the ADC value (-0.864); the fibre density in
posterior funiculus of cervical cord was positively correlated to the FA value
(0.84) while it was negatively correlated to the ADC value (-0.76).
Conclusion
Our experimental data provide valuable evidence for clinical
doctors on detecting histopathology and severity of CNS impairments directly
using imaging examination.
B-0096 11:15
A possibility of clinically using the unenhanced arterial spin-labeled MR-
perfusion in the diagnostics of acute non-haemorrhagic stroke
A.A. Khromov, S.E. Semenov, I.V. Moldavskaya, A.N. Khromova,
E.A. Zhuchkova; Kemerovo/RU (
[email protected])
Purpose: To determine a possibility of clinically using the unenhanced arterial
spin-labelled perfusion MRI (ASL) in the diagnosis of non-haemorrhagic stroke
in acute period. To study and describe the MR-semiotics of acute non-
haemorrhagic stroke with different genesis according to ASL data as compared
to the perfusion CT (PCT) as a reference method. To determine the
characteristic signs of damage according to ASL data in acute period.
Methods
and Materials: The sample group consisted of the patients with
clinically and instrumentally verified diagnosis of non-haemorrhagic ischaemic
stroke (n=30), and cerebral venous thrombosis (n=23) in the first day of onset
(acute phase). Exclusion criteria: disease duration more than 24 h, history of
cerebrovascular disorders, oncopathology. For all patients, native CT, PCT
(Iopromide-370 mg/ml), MRI in modes T2WI, FLAIR, DWI, ASL have been
performed.
Results
Reduced ASL signal in stroke zone corresponding to decrease in
CBF, CBV has been observed in 100% cases (mean rASL=0.81 ±0.17). The
perifocal increasing of ASL signal corresponding to increase in CBF, CBV was
noted in 30.19% cases in average, and it was characteristic for the venous
stroke in 75% with r ASL=1.21 ±0.19 and for the arterial ischaemic stroke in
25% with r ASL=0.93±0.26.
Conclusion
The ASL MR-method allows to detect not only stroke nucleus but
also perifocal high-signal zone as hyperaemia sign more often caused by the
cerebral venous thrombosis then arterial ischaemia in acute stage, and this
can be used for different genesis (arterial and venous) of stroke.
B-0097 11:24
MOBILE pO2 brain mapping in sub-acute ischaemic stroke
F.G. Colliez, J. Magat, M. Maia Safronova, B. Jordan, A.F. Peeters, B. Gallez,
T.P.J. Duprez; Brussels/BE (
[email protected])
Purpose: To assess the clinical applicability of brain oxygenation mapping
using the MOBILE (mapping of oxygen by imaging lipid enhancement)
technique in sub-acute ischaemic stroke patients.
Methods
and Materials: 11 sub-acute (2-3 days) ischaemic stroke patients
underwent a standardised MR protocol on a clinical 3 T MR system including
morphological and diffusion-weighted im aging together with sequences aimed
at measuring water relaxation rate R1 (with R1=1/T1), lipids R1 (MOBILE) and
R2* (=1/T2*). Regions of interest (ROIs) contouring infarcted areas and mirror
contralateral ROIs within unaffected brai n tissue were drawn on diffusion
images and overlaid on water R1, lipids R1, and R2* mapped images.
Comparison of the medians of the water R1, lipids R1 and R2* values within
diseased areas versus mirror ROIs was performed using paired t test.
Histogram analysis of the ROIs was also performed. Values obtained within
patients' unaffected mirror-ROIs were compared to those obtained in 12
healthy volunteers.
Results
Nine infarcts were included into final analysis. Decreased R1 values
were recorded within infarcts when compared to unaffected brain tissue, with
higher statistical power for lipids R1 (0.408s-1; p < 0.0001) than for water R1
(0.154s-1; p=0.027). Decreased values for R2* were recorded within ischaemic
brain. All three parameters within unaffected mirror ROIs tightly matched those
obtained in healthy volunteers (p> 0.08).
Conclusion
Selective analysis of lipids R1 has a better performance than that
of water R1 for MR-based pO2 brain mapping using the relaxation effect of
molecular oxygen as an endogenous contrast agent.
B-0098 11:33
SWAN (susceptibility-weighted angiography) visualises hypoxia in
cerebral veins
M. Patzig, B. Feddersen, K. Mees, G. Fesl;
Munich/DE (
[email protected])
Purpose: To evaluate the influence of hypox ia on the depiction of cerebral
veins in the SWAN (susceptibility weighted angiography) sequence.
Methods
and Materials: Healthy men (aged 20 - 28) were studied on MRI
under normal breathing conditions, short-term - hypoxia (7 minutes before and
during the MRI scan) and long - term hypoxia (8.5. hours before and during the
MRI scan). Two blinded readers compared the three scans of each participant
and graded the SWAN source images and minimum intensity projections
(MinIP) according to the size, number and signal intensity of the cerebral veins.
Signal intensities (SI) of deep cerebral veins were measured and SI
proportions of deep cerebral veins to different parenchymal brain regions were
calculated. Continuous pulse oximetry was performed.
Results
Nine subjects were included. In all of them, both readers correctly
distinguished the two hypoxia scans from the baseline scan, grading the
SWAN images acquired under hypoxic conditions as visualising cerebral veins
more pronouncedly. Mean SI values measured in the internal cerebral vein
were 860.6 (baseline), 580.1 (short - term hypoxia) and 626.4 (long - term
hypoxia), respectively. Overall, all mean SIs and SI proportions were
significantly lower in the hypoxia scan s. No significant differences between
short - term and long - term hypoxia were found on visual inspections and SI
measurements. These findings correlated with oxygen saturation
measurements.
Conclusion
It was shown under experimental conditions that SWAN is
sensitive to oxygen saturation changes in cerebral venous blood. Possible
clinical implications of this finding include stroke and tumour imaging.
B-0099 11:42
The DTI tractography challenge for neurosurgical planning
S. Pujol1, A. Golby1, G. Gerig2, W. Wells1, M. Styner3, L. Chauvin1,
C. Pierpaoli4, A. Nabavi5, R. Kikinis1; 1Boston, MA/US, 2Salt Lake City, UT/US,
3Chapel Hill, MD/US, 4Bethesda, MD/US, 5Kiel/DE (
[email protected])
Purpose: The purpose of this paper is to present the Diffusion Tensor Imaging
(DTI) Tractography Challenge, an international initiative to provide a
standardised evaluation of the performance of tractography algorithms for
neurosurgical planning.
Methods
and Materials: Twelve tractography teams reconstructed the
corticospinal tract from a common set of data acquired on 8 neurosurgical
cases with lesions in and near the motor cortex, in the first two editions of the
DTI Tractography Challenge workshop at the MICCAI 2011&2012
conferences. The datasets included pre-operative DWI,T1 and T2 volumes
with pre-segmented tumor and edema regions. Quantitative evaluation of the
variability among tractography results included the degree of bundle overlap
and the distance between tracts. A panel of neurosurgeons and DTI experts
S157
B A C D E F G
Thursday
assessed the anatomical correctness and depi ction of the spatial relationship
between the tracts and the tumor using a set of standardised review criteria.
Results
The 476 tractography reconstructions of the corticopsinal tract
generated by 21 different tractography methods showed large inter-algorithm
variability (average Dice coefficient of overlap: 0.22; average Hausdorff
distance between tracts:6.1 mm). The majo rity of the visualised tracts failed to
reach some clinically significant parts of the motor cortex, such as the hand
and face motor areas. Improvement in the tractography results from year 1 to
year 2 indicate that this collaborative effort is a learning experience for the
community
Conclusion
DTI tractography has a unique potential for non-invasive white
matter mapping. The DTI Challenge aims to provides a benchmark for the
standardised evaluation of tractography methods on neurosurgical data.
B-0100 11:51
Evaluation of the use of chemical shift gradient echo in and opposed
phase sequences in 3 T MRI in the detection of H-MRS visible lipids and
grading of gliomas
N. Ramli, A. Mohd Khairy, K. Rahmat, L.K. Tan; Kuala Lumpur/MY
(
[email protected])
Purpose: To evaluate the values of 3-Tesla MRI chemical shift gradient echo
(GE) in and opposed-phase sequence in discriminating between different
grades of brain glioma.
Methods
and Materials: A total of 18 patients aged between 15 and 71 years
old were enrolled (13 males, 5 females). Nine patients were diagnosed with
grade II glioma, three patients were grade III glioma and six patients were
grade IV glioblastoma multiforme (GBM). Additional in/opposed-phase and
single voxel spectroscopy sequences were done. The signal loss ratios (SLR)
were obtained from solid portion of the tumour in the in-phase and opposed-
phase. Lipid subtype concentrations were quantified by LC Model.
Results
In clinical application of glioma, the SLR in-oppose phase done on
solid component of the tumour of 0.074 allowed classification of low from high
grade with 100% sensitivity and specificity, higher than the lipid quantification
in MRS which gave highest sensitivity of 66.7% and specificity of 100%.
Conclusion
Chemical shift gradient echo in and opposed phase sequence
cause significant signal loss in diffe rent grades of gliomas with very high
specificity and sensitivity at differentiating low and high grade glioma. This
empirical finding provides new discovery that this sequence have the ability to
grade the glioma.
Author Disclosures:
N. Ramli: Research/Grant Support; High Impact Research (HIR) Grant (J-
20518-73808).
10:30 - 12:00 Room L/M
Physics in Radiology
SS 113
Advances in CT technology and
applications
Moderators:
C. Leidecker; Forchheim/DE
M. Onu; Bucharest/RO
B-0101 10:30
Fully integrated CT detector technology: evaluation of dose reduction
potential
C. Schabel, M. Bongers, S. Mangold, D. Ketelsen, C.D. Claussen, C. Thomas;
Tübingen/DE (
[email protected])
Purpose: A recently introduced novel, fully integrated design of CT detector
technology (IDT) promises low electronic noise levels compared to
conventional detector technology (CDT). The purpose was thus to evaluate the
increase in efficiency of IDT compare d to CDT and its potential radiation dose
reduction.
Methods
and Materials: Three anthropomorphic phantoms of different
diameters (19.8.27.4 and 31.6 cm) were scanned on a dual-source CT scanner
(Somatom Definition Flash) shortly before and after IDT installation
(Stellar,Siemens,Forchheim,Germany). Phantoms were constructed from
different-sized barrels cont aining water and a centred syringe filled with
contrast media of identical dilution. Phantoms were scanned using standard
clinical protocols and at additional tube current levels of 40.70,130 and 160%
of the standard tube current. Scans were repeated for different tube potentials
(80,100 and 140 kV). All other scan parameters were kept constant. Analysis
of acquired image data was performed with a custom written MATLAB tool,
which facilitated multiple identical noise and contrast measurements within the
syringe. Contrast to noise ratios were calculated.
Results
CNR increase measured was up to 24.1% and depending on tube
potential (6.1-24.1% for 80 kV,2.7-19.4% for 100 kV and 0.6-12.0% for 140 kV)
and phantom size (S 9.2-24.1%;M 0.6-16.8%;L 2.8-23.1%). It was found that
extreme combination benefit the most (S & L;40 and 160%) indicating a wider
range of good detection. Curve fitting analysis revealed that a potential
radiation dose reduction of 1.1-35.4% is possible while receiving equal CNR.
Conclusion
IDT proves to increase CNR up to 24.1% and holds out the
prospective to reduce the radiation dose up to 34.1% while acquiring images of
comparable quality.
B-0102 10:39
Optimal image-based material decomposition with energy-selective
detectors in spectral CT in comparison to dual energy CT (DECT)
S. Faby1, S. Kuchenbecker1, D. Simons1, H.-P. Schlemmer1, M. Lell2,
M. Kachelrieß1; 1Heidelberg/DE, 2Erlangen/DE (
[email protected])
Purpose: To minimise dose and maximise image quality in spectral CT when
the number of spectral energy bins B is larger than the number of materials M
to decompose into.
Methods
and Materials: Energy-selective detectors receive increasing
attention in CT since first prototypes are available. For most spectral CT
detectors, the number of energy bins B is larger than the number of materials
M one desires to separate. M=2 is of interest as it allows to distinguish soft
tissue and contrast agent. We propose a new statistics-based method to
combine the images of B >M bins into M material images that minimises the
image noise and therefore patient dose. For evaluation of our proposed
method, a CT system with energy-selective detectors is simulated with B 8
and compared to DECT. Virtual non-contrast (VNC) imaging is used to quantify
our results.
Results
An ideal energy-selective detector with B=4 allows to use 29% lower
dose than DECT in the VNC image while significantly improving the iodine
overlay image. Simulating a realistic non-ideal detector, however, would
require 57% more dose than DECT, which is required to keep the VNC image
at the same image quality.
Conclusion
It is shown that an ideal photon-counting detector could lead to a
patient dose reduction of up to 29% or more while still achieving a significantly
improved iodine image. In a more realistic scenario, however, the current
detector technology is not yet able to outperform DECT in the case considered
here.
Author Disclosures:
M. Lell: Grant Recipient; Siemens AG. Speaker; Siemens AG.
B-0103 10:48
Visualisation of energy-dependent attenuation properties in vitro and in
vivo using polar coordinates in dual-energy computed-tomography data
L. Havla, M. Peller, C. Cyran, K. Nikolaou, M.F. Reiser, O. Dietrich;
Munich/DE (
[email protected])
Purpose: Dual-energy computed-tomography (DECT) examination with two
different x-ray spectra at the same time allows for material decomposition of
calcium and iodine. The purpose of the present study was to evaluate a new
DECT post-processing approach based on the transformation of dual-energy
data into polar coordinates to ease analysis and differentiation between kind of
matter and concentration.
Methods
and Materials: Given two corresponding DECT (80 kV/140 kV with
1 mm tin filter) images, the attenuation data (ai (U1), ai (U2)) in Hounsfield
units of both energies (U1, U2) are transformed to polar coordinates, i.e., the
distance, ri, of every data point i to the coordinate origin and its angle, )_i, to
the abscissa is calculated. This approach was evaluated in a phantom
containing different substances and in vivo in N=10 rats after application of
iodine contrast agent.
Results
For phantom data, evaluation of the parameter map )(x,y) (x,y:
image coordinates) yields mean values of ) of 60.7° ±0.3°, 62.9°± 0.6°,
66.7°±0.5°, and 71.5°±0.7° for calcium, gadolinium, copper, and iodine. In vivo,
mean values of ) were 62.3°±0.4° and 71.5°±0.5° for calcium and iodine.
Conclusion
The evaluated data sets demonstrated clearly different polar-
angle ranges for different substances in vitro and in vivo. Polar-coordinate
post-processing of DECT data, thus, allows (1) to display the energy
dependence of the attenuation coefficient in a function of a single variable, the
polar angle ), (2) to select materials by characteristic polar angles, and (3) to
plot the spatial distribution of specific materials in an image with preserved
anatomic and morphologic structure ( ) maps).
S158
B A C D E F G
Thursday
B-0104 10:57
Monochromatic imaging in dual energy CT (DECT): metal artifact
reduction with acceptable image quality?
S. Kuchenbecker1, S. Faby1, S. Schüller1, M. Lell2, M. Kachelrieß1;
1Heidelberg/DE, 2Erlangen/DE (
[email protected])
Purpose: To analyse pseudo-monochromatic DECT imaging with respect to
image quality of images with metal implants.
Methods
and Materials: Today's clinical DECT systems provide pseudo-
monochromatic imaging, a linear combination of the reconstructed low and
high kV images. The linear blending factor is typically expressed as a photon
energy (in keV) and the method is called monochromatic imaging instead of
linear blending. The method is able to reduce metal artifacts under certain
patient-specific conditions. True virtual-monochromatic imaging, in contrast,
requires rawdata-based processing. We compare pseudo- vs. virtual-
monochromatic imaging and quantify image quality of both approaches.
Therefore we performed simulations of the Forbild abdomen phantom and
measured a semi-anthropomorphic phantom containing iodinated contrast
agent and metal inserts in a clinical dual source DECT with 100 kV and 140 kV
Sn tube voltage. In each case the reconstructed images were combined
linearly to minimise artifacts or to maximise the contrast-to-noise-ratio (CNR).
Results
Pseudo-monochromatic imaging reduces metal artifacts in some
cases, at cost of reduced CNR (50% and more). A dataset of the phantom
scanned in the clinical DECT system showed a CNR of 4.9 in the low energy
image and 3.7 in the high energy image. The pseudo-monochromatic image at
the energy E 139keV yields a CNR of 1.9 while the rawdata-based material
decomposition preserves the CNR=4.5 in the low energy image and CNR=3.5
in the high energy image.
Conclusion
The image-based pseudo-monochromatic imaging is a simple but
limited method to reduce metal artifacts which goes along with a significant
CNR reduction.
Author Disclosures:
M. Lell: Grant Recipient; Siemens AG. Speaker; Siemens AG.
B-0105 11:06
Suppression of the CT beam hardening streak artefact using predictive
correction on detector data
J.G. Stowe, K.M. Curran; Dublin/IE (
[email protected])
Purpose: To develop an automated program incorporating a predictive artefact
correction technique (PACT) to correct for the signal deviations from metal
beam hardening artefacts in computed tomography (CT) detector raw data.
Methods
and Materials: A thin-slice sequential CT scan was performed on a
dosimetry head phantom using a Somatom Sensation 16 scanner to establish
a ground truth image. Metal pins were then affixed to either side of the
phantom at the three and nine o'clock positions to generate streak artefact
detector raw data and a streak image. The program automatically detected the
extent of the overlap peaks in the detector raw data causing the artefact. It
profiled a correction using adjacent projections so that the peak error could be
corrected rather than simply being removed or smoothed by interpolation. The
PACT algorithm-modified raw data were then reconstructed on a SYNGO CT
reconstruction workstation. This image was then compared against base truth
and that produced by commercially available metal artefact reduction (MAR)
software.
Results
Qualitative results illustrate superior suppression of streak artefact in
images using PACT when compared directly to commercial MAR software.
Recovery of voxel data underlying the streak is also demonstrated to be
superior with PACT versus MAR when referenced to the original ground truth
image.
Conclusion
The experiment demonstrates the feasibility of this predictive
artefact correction technique in detecting and correcting beam hardening
artefact without recourse to expensive additional options such as iterative
reconstruction or dual energy that are not so commonly available in the clinical
setting.
B-0106 11:15
Metal artefact removal: single and dual-source CT approaches
T.R.C. Johnson, K. Hellbach, F.G. Meinel, M.F. Reiser, F. Bamberg;
Munich/DE (
[email protected])
Purpose: The aim of this study was to investigate the feasibility of a single-
source CT approach for the reduction of metal artefacts with spectral
extrapolation. Additionally, the effici ency was to be compared to established
dual-source CT-based methods.
Methods
and Materials: A phantom comprising implants and osteosynthetic
hardware of variable thickness and alloys of titanium or
chromium/moleybdenum/vanadium were scanned on three CT scanners, i.e. a
Siemens Flash DSCT (at filtered Sn140 and 100 kVp spectra), an Edge and a
Sensation 64 (both at 140, 100 and 80 kVp). Postprocessing was optimised to
eliminate metal artefacts by energetic extrapolation as far as possible. For
Flash and Edge, the vendor's software was used, and for the Sensation64 data
a DICOM-based custom-written software. Artefact removal was graded on a 5-
point scale.
Results
Metal artefact removal was effective in titanium prostheses and steel
hardware up to 1 cm thickness. The filtered spectra of the Flash scanner
provided most effective elimination of artefacts (rating 4.1/5) and could handle
a little thicker steel. The effectivity of the Edge with the vendor's software and
the Sensation64 with the custom-written software was equivalent (equivalent
rating of 3.6/5).
Conclusion
Dual-energy CT is an efficient approach of metal artifact
reduction. DSCT with filtered spectra achieves the best results. However,
single-source CT with two separate scans represents another efficient
approach which provides a significant improvement without exceptional
hardware.
Author Disclosures:
T.R.C. Johnson: Patent Holder; Dual Energy CT related patents.
Research/Grant Support; from Siemens and Bayer. Speaker; for Siemens.
B-0107 11:24
Assessment of CT-based thermometry during laser interstitial
thermotherapy ablation of swine pancreases
F. Giurazza, R. Del Vescovo, F. Siano, E. Schena, B.B. Zobel; Rome/IT
(
[email protected])
Purpose: Laser interstitial thermotherapy (LITT) is employed to destroy tumour
in organs; its outcome strongly depends on temperature distribution inside
tissues.
Methods
and Materials: We evaluated temperature influence on the
attenuation coefficient obtained by Hunsfi eld Unit (HU) modifications of CT
scan examinations performed during LITT on pancreatic tissue. We performed
CT scans examinations of 6 ex vivo swine pancreases while undergoing LITT
(Nd: YAG laser, 6=1064 nm, laser energy= 600 J, power= 3 W, treatment
time= 200 s) and then we measured density changes placing two regions of
interest (ROI) of 0.4 cm
2: the former, localised just upward the applicator,
presented a temperature increase and a HU decrease during LITT; the second,
at high distance from applicator, shows constant temperature and constant HU
during LITT. We have analysed HU variations on 19 consecutive scans with an
interval time of 9 seconds.
Results
Tissue density calculated in the first ROI close to the applicator
shows a decrease during LITT due to temperature rise from about 57 HU
before the treatment to 35 HU when the laser is stopped; it presents a linear
dependence with the procedural time (R2=0.8187). In the second ROI
positioned distant from the applicator, where temperature rise is negligible, the
tissue density does not show significant changes. The HU decreases as a
function of temperature, showing a nonlinear trend with a mean thermal
sensitivity of 0.50 HU C1.
Conclusion
Temperature estimation by density variation observed at CT scan
could be a suitable mini-invasive tool to choose optimal laser settings to
produce a controlled ablated volume.
B-0108 11:33
Urinary stone disease: dose and image quality in low dose CT with and
without automatic tube current modulation, with and without iterative
reconstruction
O. Soenen, F. Zanca, C. Balliauw, L. De Wever, R. Oyen; Leuven/BE
(
[email protected])
Purpose: To compare dose and image quality (IQ) of a standard low-dose CT
vs. a right-dose CT, i.e. with automatic tube current modulation (TCM), in
patients with suspected urolithiasis and to assess the value of iterative
reconstruction.
Methods
and Materials: A CT-examination was performed on 193 patients
(Siemens Definition Flash), 103 standard low-dose (120 kV, fixed 45 mAs) and
90 right-dose (120 kV, TCM with 30 mAs reference). Filtered backprojection
(FBP) reconstruction was used for both protocols and Sinogram Affirmed
Iterative Reconstruction (SAFIRE) for the right-dose only. A first-years resident
checked the standard protocol FBP images. Dose and conclusiveness were
assessed. Two experienced radiologists re-examined all cases were no stones
were found in terms of ureter stones, subjective noise, visibility of the (pelvic)
ureter and diagnostic confidence, using respectively a 3 and 4-point scale
(1=insufficient; 3/4=excellent). Unpaired t-test, Wilcoxon and Mann-Whiteny
test were used for statistical significant differences.
Results
A decrease of 22% in mean effective dose was determined
(p < 0.001) for the right-dose protocol and conclusiveness was better than for
the standard protocol: 96.2% and 78.7% respectively. The right-dose protocol
also showed an improved visibility of the pelvic ureter with respect to the
standard (median score 2 vs 1, p=0.02). For the other criteria no statistical
significant difference was found (p > 0.05). SAFIRE did not show improved IQ
(p=0.09).
S159
B A C D E F G
Thursday
Conclusion
The use of TCM for urolithiasis CT allows for a dose reduction
while preserving overall IQ and improving the visibility of the pelvic ureter.
SAFIRE seems not to improve IQ.
B-0109 11:42
Comparing the image quality of a mobile flat-panel CT and a
multidetector CT: a phantom study
J. Neubauer
1, J. Voigt2, M. Fiebich2, M. Langer1, E. Kotter1; 1Freiburg/DE,
2Gießen/DE
Purpose: To compare the image quality of a compact mobile flat-panel CT
(FPCT) capable of extremity imaging and a multidetector CT (MDCT) in
examinations with the same radiation dose.
Methods
and Materials: Monte Carlo simulations were used to calculate
equivalent dose settings for the FPCT and the MDCT. Simulations were based
on and validated by dose measurements. Homogeneity, geometric distortion,
artifacts, accuracy of Hounsfield values, contrast and spatial resolution were
evaluated in different imaging phantoms. Whitney Mann U Test and
Spearman's rho were used for statistical analysis.
Results
Homogeneity reached 2.5% for the FPCT and 0.5% for the MDCT.
Hounsfield values were more accurate and contrast to noise ratios (CNRs)
were higher for the MDCT than the FPCT. The MDCT depicted more rod
inserts than the FPCT. No geometric distortion was detected in either modality.
The FPCT was more prone to artifacts around Krischner wires with 2 mm
diameter, whereas the MDCT showed a higher amount of artifacts around
wires with a diameter of 0.8 mm. Spatial resolution was 1 lp/mm (xy), 1.7
lp/mm (z) for the FPCT and 1 lp/mm (xy), < 1 lp/mm (z) for the MDCT.
Conclusion
We compared a mobile FPCT and a 320-row MDCT by using the
same radiation dose for scans. We found the spatial resolution to be higher in
the FPCT. Hounsfield units were more accurate, homogeneity and contrast
resolution were better in MDCT. The MDCT was also less prone to artifacts
from thick Kirschner wires but showed comparably more artifacts around thin
wires.
Author Disclosures:
E. Kotter: Board Member; Editorial Board Member Thieme RadBase.
B-0110 11:51
Radiation burden from modern 256-slice CT imaging for suspected
pulmonary embolism during pregnancy: Is lung scintigraphy still more
dose efficient?
K. Perisinakis
1, A. Tzedakis1, I. Seimenis2, A. Papadakis1, J. Damilakis1;
1Iraklion/GR, 2Alexandroupolis/GR (
[email protected])
Purpose: To a) determine normalised data on absorbed radiation dose to
maternal radiosensitive organs and embryo/fetus from 256-slice CT pulmonary
angiography (CTPA) in pregnant patients suspected for pulmonary embolism,
for different maternal sizes and stages of gestation and b) provide reliable
maternal effective dose and fetal dose estimates from 256-slice CTPA for
comparison with lung scintigraphy.
Methods
and Materials: Monte Carlo methods and mathematical
anthropomorphic phantoms, generated to simulate adult females of varying
body-size at conception and at 3
rd, 6th and 9th month of gestation, were used to
simulate standard and low-dose 256-slice CTPA examinations. Normalised
dose data were derived for exposures at 80, 100 and 120 kV. Slim, average-
size and overweight pregnant patients were considered to be scanned with
80 kV-350 mAs, 100 kV-250 mAs and 120 kV-200 mAs, respectively. Mean
maternal and fetal doses were determined for 76 pregnant women considered
to be subjected to CTPA.
Results
The dose to the embryo/fetus from the standard 120 kV 256-slice CT
scan was found to be below 0.5 mGy for all stages of pregnancy. The
corresponding values for 80 kV and 100 kV 256-slice CT scans were 2-5 times
lower. Maternal effective dose from CTPA was 0.9, 1.5 and 3.2mSv for slim,
average-sized and overweight pregnant females, respectively.
Conclusion
The maternal effective dose and the radiation dose to the
embryo/fetus from modern 256-slice CTPA studies may be lower than the
corresponding typical values for lung scintigraphy. Current results may cancel
the rationale of present recommendations regarding the use of lung
scintigraphy rather than CTPA in pregnant patients suspected for pulmonary
embolism.
10:30 - 12:00 Room N/O
Vascular
SS 115
New trends
Moderators:
F. Fanelli; Rome/IT
D.L. Tarnoki; Budapest/HU
B-0111 10:30
Fusion image guidance in endovascular peripheral artery interventions
A.M.H. Sailer, M.W. de Haan, R. de Graaf, W.H. van Zwam, J.E. Wildberger,
G.-W.H. Schurink, M. Das; Maastricht/NL (
[email protected])
Purpose: To evaluate the clinical applicability, geometrical accuracy and value
of endovascular guidance by means of live fluoroscopy image fusion with
magnetic resonance angiography (MRA) and computed tomography
angiography (CTA).
Methods
and Materials: Fusion image guidance was evaluated in twenty
endovascular peripheral artery interventions (PAI) in seventeen patients.
Fifteen patients had received pre-interventional diagnostic MRA and two
patients had received CTA. Time for manually performed image co-registration
was documeted. Fluoroscopy with MRA/CTA fusion road-map accuracy was
evaluated by overlay error in millimetres. Contrast-enhanced angiogram series
(CEAS) which were not performed due to fusion guidance and total procedural
iodinated contrast media (CM) were recorded. Subjective additional value (AV)
of the fusion road-map was scored by the interventional radiologists (0 = no
AV; 1 = AV in terms of guidance; 2 = AV in terms of guidance and CM
reduction).
Results
Image co-registration was successful in all procedures within
approximately five minutes. Overlay error was less than 2 mm in nine
procedures and between 2 and 4 mm in eight. Extended patient movements
hindered fusion road-mapping in three procedures. Average CM saved per
procedure was 9 ±9 cc (range 0-30 cc) which accounted for on average
17±18% of total procedural CM (mean ±standard deviation). AV in terms of
guidance (1) was registered in six procedures and in terms of guidance and
CM reduction (2) in ten procedures.
Conclusion
Fusion-image guidance is a promising alternative to conventional
angiogram road-mapping in routine PAI, potentially reducing CM and
consecutively enhancing procedural safety for patients.
B-0112 10:39
Brain structural and haemodinamic changes caused by methcathinone
(ephedron) abuse
F. Todua, D. Gachechiladze, M. Okujava, D. Miminoshvili; Tbilisi/GE
(
[email protected])
Purpose: To assess the brain structural and haemodinamic findings in
methcathinone chronic users. This addicti ve psychoactive substance is derived
via the oxidation of ephedrine with potassium permanganate.
Methods
and Materials: 41 patients (mean age 41 years) with chronic
intravenous use of methcathinone were investigated; All patients underwent
brain MRI (1.5 T, 3 T), MR-tractography, MR-angiography and Colour Doppler
of extra-intracranial vessels, neurologi c and neuropsychological examinations,
cerebrovascular reactiviry (CVR) TCD test.
Results
In majority of abusers 32 (78%) extrapiramidal disorders similar to
Parkinson`s disease: bradikinesia, postural disturbance, araxia, tremor,
muscular distonia was noted. Pseudobulbar syndrome or personal
abnormalities was comparatively rare. Two cases of stroke was diagnosted. In
34-year-old male patient, severe dissection and thrombosis of the ICA was
marked, and in 41-year-old male, thrombosis of the MCA. MR images revealed
T1 hyperintense lesions in 35 (85%) cases, predominantly in globus pallidum
(30/74%), substantia nigra (28/68%), nuclei dentatus of cerrebulum (23/55%),
anteriot pituitary lobe (16/40%). Clinical picture was correlated with white
matter fractional anisotropy. The development of brain changes were
signficantly associated with duration of abuse. At MRA moderate to severe
vessel irregularity consistent with vasoconstriction and vasodilation was
present in 28 (68%) case. TCD revealed reduced blood flow, increased
pulsatility index (PI) values and impaired CVR.
Conclusion
MRI demonstrate systematic brain structural deficits in
methcathinone abusers. DTI identifies areas of disruption in white matter
tracts. Slowed cerebral blood flow velocity with increased pulsatility and
impaired CRV in abusers indicate increased cerebrovascular resistance due to
vasoconstriction of small cortical vessels.
S160
B A C D E F G
Thursday
B-0113 10:48
Respiratory variation of the length of the vena cava: implications for IVC
filters
T. Hashimoto, J. Koizumi, K. Yamamoto, T. Ichikawa, Y. Imai; Isehara/JP
(
[email protected])
Purpose: We evaluated the respiratory change of the length and diameter of
the vena cava using magnetic resonance imaging (MRI) in relation with
transjugular temporary filter migration.
Methods
and Materials: Twenty healthy patients were evaluated with MRI; the
length and diameter from the right brachiocephalic vein (BCV) to the pararenal
inferior vena cava (IVC) were measured.
Results
The lengths of the BCV, superior vena cava (SVC), RA, suprarenal
and pararenal IVC during expiration vs. inspiration were 32.7 ±7.3 mm vs.
43.0 ±8.0 mm, 44.6± 9.6 mm vs. 58.5 ±12.7 mm, 77.8± 12.4 mm vs.
98.9±10.0 mm, 104.6 ±19.1 mm vs. 85.0 ±14.9 mm, and 49.0 ±8.7 mm vs.
33.8±9.7 mm respectively. The distances from the BCV to the RA, from BCV to
the upper confluence of RV, and from BCV to the lower confluence of RV
during expiration vs. inspiration were calculated as 155.2 ±18.5 mm vs.
200.34 ±20.1 mm, 255.6 ± 27.7 mm vs. 285.6 ±23.9 mm, and 308.7± 31.6 mm
vs. 319.1± 24.9 mm. The diamaeter of the SVC, the suprarenal IVC, the
infrarenal IVC during expirati on vs. inspiration were 18.6 ±2.89 mm vs.
16.4 ±3.0 mm, 15.9± 4.6 mm vs. 14.6 ±5.23 mm, and 14.9 ±4.8 mm
vs.18.0±4.4 mm, respectively. There were statisti cally significant differences in
both vena cava lengths and diameters except the diameter of the suprarenal
IVC between expiration and inspiration.
Conclusion
This study demonstrates that the distance from the BCV to the
RA, the upper and lower confluences of RV was 4.5 cm, 2.6 cm and 1.0 cm
longer at inspiration than at expiration. These respiratory-associated changes
of the vena cava length should be considered to prevent transjuglar temporary
filter migration.
B-0114 10:57
Study for percutaneous transluminal angioplasty for dysfunctional
femoral haemodialysis graft fistula
E. Oh
1, Y. Kim1, D. Goo1, S. Yang2; 1Seoul/KR, 2Gumi/KR
(
[email protected])
Purpose: To analyse the radiologic features of dysfunctional femoral
arteriovenous graft and to evaluate various predictors of graft patency rates
after percutaneous transluminal angioplasty (PTA).
Methods
and Materials: A retrospective analysis was performed to 45
patients who underwent femoral arteriovenous graft placement for
haemodialysis and who were referred for PTA for dysfunction between 2005
and 2012. The primary and secondary patency rates after PTA was evaluated.
Difference of the primary patency rates according to the presence of diabetes
mellitus, graft age from the time of creation to the first intervention ( < 12
months or 12months), presence of thrombus, shape of graft (U shape or
straight shape), anastomosis type of graft (femoral-femoral vs femoral-
saphenous), location of stenosis (central vs peripheral), length of
stenosis (< 2 cm vs 2 cm), degree of stenosis severity (< 70% vs 70%), and
stent insertion or not were estimated.
Results
A total of 124 PTA were performed. For femoral arteriovenous graft,
post-PTA primary and secondary patency rates at 3, 6, and 12 months were
84.8%, 63.6%, 24.2%, and 95.2%, 95.2%, 85.7%, respectively. The average
post-PTA primary and secondary patency rates were 13.2 months and 35.7
months, respectively. Metallic stents were inserted in nine of 124 proceducres.
There were no significant difference of the primary patency rates for various
predictors except between stent insertion group and no insertion group.
Conclusion
PTA is safe and effective treatment modality to treat
dysfunctional femoral haemodialysis gr aft fistula. There was statistically
significantly low patency rate in the group of patients by inserting a stent.
B-0115 11:06
Visceral fat accumulation is a risk factor for atherosclerosis of the aorta
M. Hrabak Paar, R. Štern-Padovan; Zagreb/HR (
[email protected])
Purpose: To evaluate the relationship between the amount and distribution of
abdominal adipose tissue with development of atherosclerotic changes of the
aorta.
Methods
and Materials: MSCT angiography of the entire aorta was performed
in 94 patients (68 men and 26 women; age range 40-85 years). In all patients
significant aortic disease was excluded using CT examination. Total, visceral
and subcutaneous abdominal fat areas were measured on a single axial CT
scan at the level of umbilicus. Aortic diameter and wall thickness of different
aortic segments was measured, and atherosclerotic plaques of all aortic
segments were semi-quantitatively graded. Correlation analysis between
abdominal fat areas and aortic diameters, wall thickness and plaque grades
was performed.
Results
We found statistically significant correlation between diameter of all
aortic segments and visceral fat area, that was mostly pronounced in the aortic
arch (r=0.42, p < 0.05). Aortic wall thickness was associated with visceral fat
area, this relationship was strongest at the level of descending thoracic aorta
(r=0.32, p < 0.05). We also found positive corr elation between the visceral fat
area and the grade of the largest atherosclerotic plaque of all aortic segments,
with the strongest correlation at the level of descending thoracic and abdominal
aorta (rs=0.32, p < 0.05). We did not find any correlation between
subcutaneous fat area and aortic wall thickness and atherosclerotic plaque
grade.
Conclusion
Visceral fat accumulation accelerates vascular aging, with
consequent increase of the risk for future cardiovascular events. The effect of
subcutaneous fat tissue on development of aortic atherosclerosis is negligible.
B-0116 11:15
Acute basilar artery occlusion: a safety and efficacy single-centre study
F.X. Zarco, A. Lopez, M.F. Werner, L. San Roman, J. Blasco, S. Amaro,
Á. Chamorro, L. Oleaga, J.M. Macho; Barcelona/ES
(
[email protected])
Purpose: The purpose of this study was to evaluate the safety and efficacy of
mechanical thrombectomy in subjects with acute basilar artery occlusion.
Methods
and Materials: This retrospective single-center study includes 25
consecutive patients with acute basilar artery occlusion treated within 24 hours
after symptoms onset with mechanical thrombectomy. Recanalisation rates,
time to treatment, duration of the procedure, hemorrhagic transformation,
clinical outcome and mortality rate at 90 days were collected.
Results
The mean age of patients was 61± 19 years, and the median
prethrombectomy NHISS score was 20 (IQR 11-30). The mean time to
treatment was 354.54 ±212.40 minutes, and the mean endovascular treatment
time was 88.22 ±46.52 minutes measured from needle to final angiogram.
Successful recanalisation (TICI 2b/3) was achieved in 22 patients (88.9%). No
patients suffered parenchymal hematoma (0%) as a complication of the
procedure. A favorable outcome (0-2mRS) at 3 months was observed in 36.4%
of the patients (8/22), and the mortality rate was 40.9%(9/22).
Conclusion
Our preliminary results show better results in terms of rate of
successful revascularisation (88.9%vs53-65%), funcional
outcome (36.4%vs20-24%) and mortality rate (40.9%vs50-56%) than
previously published reports for intravenous or intra-arterial thrombolysis. The
recanalisation rates (88.9%), functional outcome rates (36.4%)are comparable
to those obtained in other reports. However, our mortality rate (40.9%) is
slightly higher than other series (21-35.7%), probably because we have
missing data in 3 month follow-up. Mechanical thrombectomy in acute basilar
artery occlusion is feasible and effecti vely contributes to a high-rate of
recanalisation and improves funcional outcom e in patients wi th ABAO with a
low complication rate. These preliminary results must be confirmed in
prospective studies.
B-0117 11:24
Endothelial function assessed by ultrasound flow-mediated dilatation in
patients with haematologic malignancies subjected to high-dose
chemotherapy in the course of haematopoietic stem cell transplantation
M. Poreba, R. Poreba, P. Gac, L. Usnarska-Zubkiewicz, W. Pilecki,
K. Kuliczkowski, G. Mazur, M. Sobieszczanska; Wroclaw/PL
(
[email protected])
Purpose: Examine endothelial function in patients with haematologic
malignancies subjected to high-dose chemotherapy (HSCT) in the course of
haematopoietic stem cell transplantation by means of ultrasound flow-mediated
dilatation (FMD).
Methods
and Materials: The studies were conducted on 43 consecutive
patients qualified for HSCT following high-dose chemotherapy based on the
current standards. Evaluation of endothelial function by means of ultrasound
FMD was conducted in 43 patients with haematological malignancies before
HSCT (test A) and after HSCT (test B). We accepted the FMD value 7% as a
norm.
Results
Brachial artery diameter 2 minutes after 5-minute vasoconstriction
period, change in brachial artery diameter, and FMD were significantly lower
after HSCT as compared to the results obtained before the transplantation
(p < 0.05). Before HSCT procedure normal FMD was present in 92.11% of
patients. After HSCT procedure normal FMD was found significantly less
frequently, in 36.84% of patients (p < 0.05). The multifactorial step-wise
backward regression analysis indicated that administration of fludarabine and
cytarabine and higher concentrations of blood creatinine represented risk
factors for the impairment of endothelial function expressed as decreased FMD
value.
Conclusion
In patients with haematopoietic malignancies treated with HSCT,
endothelial function assessed by the ultrasound flow-mediated dilatation was
impaired after chemotherapy and stem cells administration.
S161
B A C D E F G
Thursday
B-0118 11:33
Assessment of intrarenal flow Doppler parameters in patients before and
after pheochromocytoma tumour removal
M. Januszewicz, I. Pruszynska, O. Rowinski; Warsaw/PL (
[email protected])
Purpose: Pheochromocytoma is a neuroendocrine tumour derived from
chromaffin cells in the medulla or adrenal glands. Secretion of norepinephrine
or epinephrine may have an effect on the flow of blood in the arterial vessels.
The Doppler study was performed to assess potential changes of intrarenal
flow presented by resistance indexes.
Methods
and Materials: 116 patients treated for pheochromocytoma (56 men,
mean age 50.2y ±19.59) were divided into two groups: before (80) and after
(35) adrenalectomy, and according to gender. The control group consisted of
121 patients (79 men, mean age 47y ±14.82). Doppler examinations were
performed with Philips HD11 and HD22 (Philips Andover, MA, USA) equipment
using convex transducer 2-4Mhz.The renal size, resistive and pulsality (RI,PI)
indexes and acceleration time (At) were measured in intra-lobar arteries of
upper and lower parts of the kidney. Analysis of variance (ANOVA) was used
when possible, if not possible U te st was conducted. Multiple regression
analysis was used in tests including quantitative values.
Results
Control and study groups demonstrated a significant correlation
(p < 0.05) of RI with age and gender of the patient. Conducted tests failed to
demonstrate a significant correlation between any of the indicators and the
state before and after surgery.
Conclusion
The impact of age on measured values was significantly visible in
study and control groups. Adrenalectomy did not significantly change values of
RI, PI and At. The Doppler study does not show the influence of
catecholamines secretion on renal flow.
B-0119 11:42
Hypoplasia of the vertebral artery: impact on cerebellar blood flow and
perfusion characteristics
K.M. Thierfelder, L. von Baumgarten, F.G. Meinel, M. Armburster, K. Nikolaou,
M.F. Reiser, W.H. Sommer;
Munich/DE (
[email protected])
Purpose: Hypoplasia of the vertebral artery (VAH) is a common vascular
variant and a risk factor for posterior circulat ion ischemia. The aim of our study
was to determine whether VAH leads to a perfusion deficit in the dependent
PICA-territory.
Methods
and Materials: Vertebral artery diameter was measured in the V4
segment of 934 consecutive patients who underwent multimodal CT due to
suspected stroke. VAH was defined by a V4 diameter of up to 2 mm in the CT-
angiography. Patients with posterior circulation ischemia, hemorrhagic stroke
or other vertebrobasilar pathologies were excluded. The study was designed
as a case-control study with a ratio of cases to control patients without VAH of
1:2. Two readers evaluated four different perfusion maps for perfusion deficits
in the cerebellum of all patients.
Results
VAH was found in 15.6% with a right sided preponderance (61.6%
right VAH). A perfusion deficit in the PICA-territory was present in up to 37.9%
of patients with VAH. Time-to-drain (TTD) was the most sensitive map with
regard to VAH (sensitivity of TTD 37.9%), followed by mean transit time
(35.6%), and cerebral blood flow (34.5%). Cerebral blood volume was not
affected in any patient. Cerebellar perfusion deficits were significantly more
frequent in patients with VAH than in the control group (7.6%, p < 0.001).
Conclusion
VAH can lead to a perfusion deficit in the cerebellum. CT
perfusion readers have to be aware of this vascular variant. Its hemodynamic
consequences must not be mistaken for acute ischemia.
B-0120 11:51
Evaluation of computational wall stress analysis as an additional
characterisation tool of small infrarenal abdominal aortic aneurysms
T. Nguyen-Kim, L. Jost, T. Pfammatter, T. Frauenfelder; Zurich/CH
(
[email protected])
Purpose: To evaluate the impact of computational wall stress analysis in
computed tomography (CT) of ruptured and not-ruptured small infrarenal
abdominal aortic aneurysms (AAA) with a diameter of approximately 55 mm as
an additional predictor for rupture.
Methods
and Materials: 24 patients (median age 72years) with small
infrarenal AAA (mean diameter 52.92 ±5.2 mm) underwent CT-angiography of
the abdomen. Two groups were formed: group1 (9 patients with acute clinical
symptoms and ruptured AAA), group2 (15 patients without clinical symptoms
and not-rupture d AAA). Using dedi cated software (A4clinics VASCOPS)
structural analysis of the infrarenal AAA with the finite element method was
performed evaluating exterior and luminal diameter, intraluminal thrombus (ILT)
thickness, vessel-, luminal- and ILT-volume, peak wall stress (PWS), peak wall
rupture risk (PWRR). Additionally the mi ses-stress and rupture risk-index in the
ILT were calculated. Non parametric tests were used for comparison of the two
groups.
Results
The maximum exterior diameter, mean total vessel-volume and ILT-
thickness did not significantly differ between both groups (group1:
53.6±6.1 mm, 133.3± 38.5 cm3, 11.3 ±9.1 mm; group2: 53.3 ±5.2 mm,
123.3±52.2 cm
3, 14.9 mm ±8.3 mm,(p> 0.11)). The maximum luminal-diameter
and luminal-volume was significantly lower for group2 (group1:47.9 ±21.9 mm,
70.9±27.4 cm3; group2:39.2 ±7.5 mm, 54.6± 21.7 cm3,p0.046), whereas the
ILT-volume was significantly higher
(group1:42.0±32.1 cm
3,group2:51.9±34.1 cm3,p=0.047). In group1 ILT
mean/maximum mises-stress (group1:6.3 ±2.4kPa/24.5±12.5kPa;
group2:5.6±0.4kPa/20.1±5.2kPa) and maximum rupture risk-index
(group1:0.41±0.2; group2:0.32 ±0.08) were significantly higher (p < 0.041).
Mean PWS and PWRR were lower in group2 (group1:105.9 ±24.1kPa,
0.24±0.09; group2:101.4±35.3kPa; 0.28±0.07), but not significantly different.
Conclusion
In patients with equal small AAA diameters the ILT-volume and
the finite element analysis may serve as additional predictors for risk-
stratification.
10:30 - 12:00 Conf. Room M3
Interventional Radiology
SS 109
New IR techniques and animal studies
Moderators:
J.M. Lee; Seoul/KR
C. Rosenberg; Greifswald/DE
B-0121 10:30
Early experience of a commercial available robot (Maxio) for CT-guided
radiofrequency ablation of liver tumours
B.J. Abdullah
1, C.H. Yeong1, K. Goh1, B. Yoong1, G. Ho1, A. Kulkarni2;
1Kuala Lumpur/MY, 2Florence, OR/US (
[email protected])
Purpose: To assess the accuracy of needle placement, radiation dose and
performance level during robotic-assisted radiofrequency ablation (RFA) of
liver tumours using a CT-guidance robotic system.
Methods
and Materials: 19 patients were treated with RFA with the
assistance of a robotic system (Maxio, Perfint Healthcare, USA). All the
procedures were performed under general anaesthesia. Following baseline CT
scans, the lesions were identified. The treatment was planned on the Maxio
workstation. The accuracy of needle placement, number of readjustments and
total radiation dose to each patient were recorded. The performance level was
documented for each procedure on a five-point scale (5-1: excellent-poor). The
radiation doses and readjustments were compared against 30 RFA patients
treated without robotic assistance.
Results
RFA was successfully completed in all the patients. All the lesions
were targeted successfully with the guidance of robot. Performance levels
were all 5 except in one patient (4). The total radiation dose (CTDIvol) of the
robotic-assisted RFA was 411.37+-239.22 mGy, whereas the conventional
RFA was 597.10+-437.63 (p < 0.05). The fluoroscopic dose (DLP) for the
robotic and non-robotic assisted RFA were 596.11+-360.16 mGy.cm and
832.23+-642.80 mGy.cm, respectively (p < 0.05). There were no immediate
complications noted in either group.
Conclusion
Robotic-assisted RFA improves the accuracy of needle
placement, reduce number of needle passes, and significantly reduce the total
radiation dose to the patients.
Author Disclosures:
B.J. Abdullah: Equipment Support Recipient; Perfint. Investigator; Publication.
Speaker; worshop.
B-0122 10:39
Electromagnetically navigated TIPS procedure: phantom and in vivo
evaluation
P. Isfort1, H.-S. Na1, T. Penzkofer1, C. Wilkmann1, S. Osterhues1, A. Besting2,
T. Schmitz-Rode1, C.K. Kuhl1, P. Bruners1; 1Aachen/DE,
2Herzogenrath/DE (
[email protected])
Purpose: To evaluate the feasibility of electromagnetic tracking (EMT)
transjugular intrahepatic portosystemic shunt (TIPS) placement in a phantom
and in vivo setting.
Methods
and Materials: A custom-designed TIPS set consisting of a stainless
steel stylet, a polypropylene catheter and a stainless steel outer canula was
developed. In the tip of both stylet and outer canula, coils were integrated to
allow tip detection through an electromagnetic tracking system (Aurora,
Northern Digital, Waterloo, Canada). For navigation of the TIPS set, a software
prototype was developed that allows visualisation of both the stylet and the
outer canula tip position in a previously acquired C-arm CT dataset. The EMT-
TIPS procedure was performed in a custom made gel-wax phantom (n=80
trials) and in 8 domestic pigs. Domestic pigs were chosen as an animal model
S162
B A C D E F G
Thursday
for challenging TIPS procedures. Time/number of punctures aiming at the
portal vein was recorded.
Results
In the phantom setting intervention time to cannulate the portal vein
(PV) was 144.0 ± 62.8 s. A mean of 1.2 ± 0.4 punctures was needed for PV
cannulation. In the in vivo trials, the TIPS procedure was successfully
performed in 5 out of 8 animals. Time for the complete TIPS procedure
including prosthesis placement ranged from 40 to 562 minutes with a notable
learning curve between the trials.
Conclusion
EMT guidance of TIPS placement proved to be feasible in vitro
as well as in vivo. The system holds promise to substantially facilitate
challenging TIPS procedures.
B-0123 10:48
Laser-assisted transjugular intrahepatic portosystemic shunt: an
experimental study
J. Koizumi1, C. Itou1, N. Mori1, T. Hashimoto1, H. Shiozaki2, T. Sekiguchi1,
T. Ichikawa1, Y. Imay1, B. d'Othée3; 1Isehara-City/JP, 2Tokyo/JP, 3Baltimore,
MD/US (
[email protected])
Purpose: Transjugular intrahepatic portosystemic shunt (TIPS) is widely
applied to prevent rebleeding of esophag eal varices or to control refractory
ascites. However, it is sometimes difficult to reach portal vein due to rigid
hepatic parenchyma, acute angle between hepatic and portal vein, etc. Thus,
we introduced a laser probe instead of conventional needles.
Methods
and Materials: For normal porcine liver, 15 J/cm (Group A) vs. 150
J/cm (Group B) were directly delivered each ten times by a 980 nm of diode
laser probe in a saline bath. Each traverse area of the vaporided holes,
coagulation and carbonised tissues was measured in both groups. TIPS was
attempted after guidewire negotiation of the hole created by a laser fiber via a
Rosche-Uchida set.
Results
In group A, 0.36 ± 0.14 mm2 of holes with surrounding 3.9 ± 1.6 mm2
of coagulation were observed, while carbonization was not identified. In group
B, 5.5 ± 2.6 mm2 of carbonization surrounded by 57.8 ± 23.7 mm2 of
coagulation were identified without definite holes. The coagulation areas of
group A were significantly (p < 0.01) smaller than the ones of group B. After
TIPS creation in group A, the coagulation was negligible due to the extended
tissue by a stent.
Conclusion
For TIPS creation, low energy laser is feasible to open holes to
allow passage of a guidewire instead of conventional needles.
B-0124 10:57
Image-guided periarterial ethanol sympathicolysis for renal denervation:
a feasibility study in pigs
F. Streitparth, A. Walter, N. Stolzenburg, P. Freyhardt, B. Gebauer, B. Hamm,
R.W. Günther; Berlin/DE (
[email protected])
Purpose: The aim of this study was to evaluate the feasibility and efficacy of
image-guided periarterial ethanol injection as an alternative to transluminal RF
ablation.
Methods
and Materials: Unilateral renal periarterial ethanol injection was
performed under general anaesthesia in 6 pigs with the contralateral kidney
serving as control. All interventions were performed in an open 1.0-T MRI
system using real-time multiplanar guidance. The injected volume was 5 ml
(95% ethanol labelled marked MR contrast medium) in 2 pigs and 10 ml in 4
pigs. Four weeks post-treatment the pigs underwent MRI including MRA and
were killed. Norepinephrine (NE) concentration in the renal parenchyma served
as a surrogate parameter to analyse the efficacy of sympathetic denervation. In
addition, the renal artery and sympatheti c nerves were examined histologically
to identify evidence of vascular and neural injury.
Results
In pigs treated with 10 ml ethanol, treatment resulted in neural
degeneration. We found a significant reduction of NE concentration in the
kidney parenchyma of 53% (p < 0.02) compared with the untreated
contralateral kidney. In pigs treated with 5 ml ethanol, no significant changes in
histology or NE were observed. There was no evidence of renal arterial
stenosis in MRI, macroscopy or histology in any pig.
Conclusion
MR-guided periarterial ethanol injection was feasible and efficient
for renal sympathetic denervation in a swine model. This technique may be a
promising alternative to the catheter-based approach in the treatment of
resistant arterial hypertension.
B-0125 11:06
Chemosaturation with percutaneous hepatic perfusions (PHP) of
melphalan for hepatic metastases: experience at two European centers
T.J. Vogl
1, J.-E. Scholtz1, S. Zangos1, J. Trojan1, K. Zacharowski1, F. Orsi2,
P. Ferruci2; 1Frankfurt a. Main/DE, 2Milan/IT (
[email protected])
Purpose: Chemosaturation with percutaneous hepatic perfusion (PHP;
Hepatic CHEMOSAT® Delivery System; Delcath Systems Inc, USA) is a
minimally invasive, repeatable regional therapy for unresectable hepatic
metastases. It uses a system of catheters and filters to isolate hepatic venous
blood from the systemic circulation, allowing delivery of high-dose
chemotherapy to the hepatic artery. Effluent hepatic venous blood is filtered
before returning it to the systemic circulation, thereby reducing exposure to
chemotherapy. We describe our experiences with chemosaturation-PHP at 2
European centres.
Methods
and Materials: Fourteen patients presented with unresectable
hepatic metastases from solid tumours; 13 received 1-3 sessions of
chemosaturation-PHP. Melphalan 2.0 (n=1) or 3.0 (n=12) mg/kg was given as
a 30-minute infusion into the hepatic artery. Twelve patients were evaluable for
tumour response.
Results
One complete (cholangiocarcinoma, n=1) and 6 partial responses
(ocular, n=3 or cutaneous melanoma, n=3) were observed; 5 patients had
stable disease (ocular melanoma, n=3; breast cancer, n=1; gastric cancer,
n=1). Mild to moderate filter-related toxicity (i.e. thrombocytopenia, anaemia)
was observed immediately post-procedure. Grade 3/4 melphalan-related
pancytopenia developed after 1-2 weeks. All haematological events were
managed effectively with transfusions and/or other supportive measures. The
new high-efficiency filter showed milder toxicity and faster recovery. In one
case, chemosaturation-PHP was abandoned prematurely due to heparin-
induced vaginal-bleeding, and one patient died due to retroperitoneal
haemorrhage from heparin anti-coagulation.
Conclusion
Chemosaturation-PHP for non-resectable liver metastases is a
feasible treatment option when performed by an experienced multi-disciplinary
team. It may be a promising regional therapy for patients with no effective
treatment options.
B-0127 11:15
Fluoroscopy-guided infiltration for pain reduction in patients with
Baastrup disease: clinical experience and results
G. Velonakis, D. Filippiadis, A. Mazioti, A. Malagari, E. ALexopoulou,
N. Kelekis, A.D. Kelekis; Athens/GR (
[email protected])
Purpose: Baastrup disease refers to degenerative changes of adjacent
spinous processes with resultant back pain. Purpose of this study is to assess
safety and efficacy of percutaneous, fluoroscopy-guided infiltrations in a
consecutive series of patients suffering from Baastrup disease (diagnosed
clinically and by imaging findings).
Methods
and Materials: During the last 4 years, 55 patients suffering from
Baastrup disease (diagnosed clinically and by imaging findings) underwent
percutaneous, fluoroscopy-guided infiltration. The position of the needle (22
Gauge spinal needle) was fluoroscopically verified at the level of interspinous
ligament. Then a mixture of long acting glucocorticosteroid with local
anaesthetic (1.5/1 cc) was injected. A questionnaire with NVS scale helped
assessing pain relief degree, life quality and mobility improvement.
Results
In the patients of our study a total of 67 sessions was performed. In
12/55 patients (21.8%) a second infiltration was performed within 7-10 days
apart from the first one. Comparing the pain scores prior (mean value
8.18±1.44 NVS units) and after (mean value 0.62 ±0.93 NVS units) there was a
mean decrease of 7.56 ±1.686 NVS units (p < 0.001) on terms of pain
reduction, effect upon mobility and life quality. There were no clinically
significant complications noted in our study.
Conclusion
Fluoroscopy-guided infiltrations seem to be a feasible, efficacious
and safe approach for pain reduction and mobility improvement in patients with
Baastrup disease.
B-0128 11:24
Next generation multimodal visible embolisation particles: feasibility
study in rabbit and pig animal models
J. Budjan, E. Appel, T. Nguyen, S. Diehl, S.O. Schönberg, C. Reis,
S.H. Bartling; Mannheim/DE (
[email protected])
Purpose: Aim of this study is to produce and test next generation, multimodal
visible (X-ray, CT, MRI), embolisation pa rticles with a narrow particle size
distribution and synthesised in a new automated process under 100% quality
control. Aim of the study is to assess the visibility, manageability and ability to
perform controlled, selective embolisation with the particles in vivo.
Methods
and Materials: Particles with a diameter of 200 m and a narrow
particle size distribution ( ± 5% deviation in diameter) are synthesised in a
closed-loop automated process. An optimised monomer blend of an iodine
containing monomer with an additional cross-linker is polymerised. The
monomer blend contains superparamagnetic iron oxide particles. A kidney
embolisation model was used. A total of 4 rabbits and 2 pigs were embolised in
an X-Ray angiography/Dyna-CT-Setup (Siemens Artis Zeego) under live image
control. The animals were examined in clinical MRI (Siemens Magnetom Trio,
T1 VIBE, T2* and T2) and CT (Siemens Somatom Definition, 120 kV, 260 mAs,
0.6 mm collimation) scanners directly before and after embolisation.
Results
The particles were visible in CT, MRI and during embolisation in X-
Ray/Dyna-CT. A controlled segmental kidney embolisation could be achieved.
Periinterventional imaging demonstrated particles in all 3 imaging modalities
and in positive correlation to histology which showed proper thrombogenesis.
S163
B A C D E F G
Thursday
Conclusion
The automated synthesis process allows the creation of high
quality MR, CT and X-Ray visible embolisation particles with a narrow particle
size distribution, that will allow, novel, approaches to personalised treatment
concepts and therapy monitoring.
B-0129 11:33
Utility of cone beam computed tomography and ablation planning
software for monitoring of ultrasound-guided microwave ablation of liver
malignancies
C. Floridi, G. Carrafiello, A. Ierardi, E. Macchi, F. Fontana, C. Fugazzola;
Varese/IT (
[email protected])
Purpose: To prospectively evaluate the utility of C-arm Cone Beam Computer
Tomography (CBCT) and ablation planning software for monitoring of
ultrasound-guided microwave ablation (MWA) of liver malignancies and report
on feasibility and short-term outcome.
Methods
and Materials: Between November 2012 and September 2013
fourteen patients (11 men, 3 women; mean age, 68.5 years) underwent MWA
of 15 liver lesions (10 hepatocellular carcinomas, 5 metastatic tumours; mean
size 25.3 mm) using a C-arm CBCT. Intra-procedural dual-phase CBCT
(arterial and venous) after intravenous contrast administration was performed
to determine optimal approach to the lesion (s) using dedicated ablation
planning software. MW antennas were positioned under ultrasound guidance
and non-enhanced CBCT was performed after deployment. CBCT acquired
before and after antenna deployment was registered to evaluate tumour
targeting. Diagnostic contrast-enhanced CT was used in case CBCT did not
accurately depict lesions. CBCT lesion detection accuracy and number of
needle re-positioning on the basis of CBCT and software information were
recorded. Clinical success was measured on follow-up contrast-enhanced CT.
Results
All procedures were completed without complications. C-arm CBCT
detected 14 of the 15 lesions (93.3%) and registration with diagnostic CT was
required in 1 (6.7%). MW antennas were repositioned on the basis of CBCT
and software in 10 lesions (76%). Clinical success was achieved in 12
ablations (80%) while 3 (20 %) presented with local recurrence on follow-up.
Conclusion
Monitoring of ultrasound-guided MWA of liver tumours using C-
arm CBCT and ablation planning software is feasible and leads to needle re-
positioning in the majority of cases.
B-0130 11:42
Irreversible electroporation (IRE) in an acute porcine liver model: effect of
previous transarterial embolisation with iodised oil (TAEio) on technical
parameters, CT 3D rendering of the electroporation zone, and histology
C.M. Sommer
1, D.F.J. Vollherbst1, S. Zelzer1, M.F. Wachter1, S. Aulmann1,
U. Stampfl1, P.L. Pereira2, H.-U. Kauczor1, B.A. Radeleff1; 1Heidelberg/DE,
2Heilbronn/DE (
[email protected])
Purpose: To evaluate the effect of previous transarterial embolisation with
iodised oil (TAEio) on technical pa rameters, CT 3D rendering of the
electroporation zone, and histology after IRE in an acute porcine liver model.
Methods
and Materials: In five landrace pigs, two IREs of the right liver (RL)
and two IREs of the left liver (LL) were performed with identical system
parameters. Before IRE, a selective transarterial embolisation of the left liver
was performed with iodised oil until stasis. CT examinations were performed
non-enhanced and contrast-enhanced to assess the extent of the
electroporation zone. After IRE, animals were killed, and livers harvested.
Mean resulting voltage and amperage were assessed during IRE. For CT 3D
rendering of the electroporation zone, parameters for size and shape (e.g.
short axis, volume, and sphericity index) were analysed. Histological
differences were assessed.
Results
Mean resulting voltage and amperage were 2545.3 ±66.0V and
26.1±1.8 A for RL, and 2537.3± 69.0V and 27.7 ±1.8 A for LL without significant
differences. Short axis, volume and sphericity index were 16.5 ±4.4 mm,
8.6±3.2 cm3 and 1.7 ±0.3 for RL, and 18.2± 3.4 mm, 9.8± 3.8 cm3 and 1.7± 0.3
for LL without significant differences. For RL and LL, the electroporation zone
consisted of severely widened hepatic sinusoids containing numerous
erythrocytes, and showed homogeneously apoptosis. For LL, iodised oil could
be detected histologically in the center and at the rim of the electroporation
zone.
Conclusion
In this acute porcine liver model, there was no adverse effect of
previous TAEio on technical parameters, CT 3D rendering of the
electroporation zone, and histology after IRE.
Author Disclosures:
C.M. Sommer: Grant Recipient; AngioDynamics Research Grant
10:30 - 12:00 Board Room A
Radiographers
SS 114
Conventional radiography: exposure
indices, image quality and patient dose
Moderators:
E. Atalar; Ankara/TR
D. Pekarovic; Ljubljana/SI
B-0131 10:30
A European collaborative investigation into the impact of additional
copper filtration upon dose and image quality for adult chest
examinations
N. Mekiš1, L.A. Rainford2, T. Starc1, G. Paulo3, S. Foley2, J. Santos3;
1Ljubljana/SI, 2Dublin/IE, 3Coimbra/PT
Purpose: To investigate the impact of additional copper (Cu) filtration upon
radiation dose received and image quality during adult chest examinations.
Methods
and Materials: Chest examination protocols across Slovenian
clinical sites (n=10), detailing: kV, FFD, AEC selection; DR/CR technology, X-
ray beam filtration levels were identified. Experimental protocols (n=36) were
formulated with referral to Portuguese protocols (n=4) currently employing
additional Cu filtration, parameters tested included: 125-150 kVp; 150 cm FFD
(AEC:R) and 180 cm FFD (AEC:R+L); 2.5 mmAl with additional filtration levels
of 0.1-0.3 mm Cu. A Whole Body PBU-60 phantom was imaged in a postero-
anterior chest position. DAP measurements and dose at the thyroid, thorax
surface (position of the right breast) and superior breast surface were
recorded. Image quality evaluation, incorporating CEC anatomical structure
scoring, was performed by radiologists from Slovenia and Portugal (n=6) using
Viewdex software, 3MP Barco monitors and ambient lighting levels < 40 lux.
VGC analysis compared preset protocols with experimental copper filtration
findings.
Results
Application of up to 0.3 mm Cu additional filtration resulted in DAP
reductions of 33%. VGC findings identified optimal combinations of 180 cm
FFD, 125 kV and 0.2 mm Cu, resulting in a 24% DAP reduction and 150 cm
FFD, 145 kV and 0.3 mm Cu recording a 30% DAP decrease. Additional
copper filtration reduced dose by up to 57%, 40% and 20% for the thyroid, the
superior and inferior breast surfaces respectively.
Conclusion
Reductions in DAP values of up to 33% were identified for
increased copper filtration levels, whilst image quality maintenance was
quantified using VGC analysis for 180 and 150 cm FFD parameters.
B-0132 10:39
Visual evaluation of target exposure index and deviation index on chest
x-ray image using digital radiography system
S. Fujimoto
1, M. Shimada1, T. Kata1, E. Kidoya1, Y. Hasegawa1, T. Adachi1,
H. Kimura1, Y. Mochizuki2, Y. Kitanaka3; 1Yoshida-gun/JP, 2Saitama-shi/JP,
3 Minato-ku/JP (
[email protected])
Purpose: The purpose of this study is to examine visual evaluation of target
exposure index (EIt) and deviation index (DI) specifically for chest X-ray image
using digital radiography (DR) system based on the methods of EI and DI
defined by IEC and AAPM.
Methods
and Materials: At various EI settings, Chest X-ray images with mimic
tumours on the back of the chest phantom (KYOTO KAGAKU) were examined
with DR system (Philips). For evaluating the EI range under proper image
quality, sensory test (Scheffe's paired comparison) was performed by 10
radiological technologists focusing on noise of the mimic tumours. In addition,
observation ratio on contrast-detail phantom (KYOTO KAGAKU)-examined
various EI values were evaluated by the same radiological technologists.
Results
No significant difference was found under EI range between
approximately 400 and 800 by the sensory test. Also EI values of 400 and 800
showed high observation ratio of approximately 95% and 97%, respectively.
However, 150 and 1400 EI showed approximately 90% and 98% observation
ratio, respectively, were considered under and over exposure, respectively.
Conclusion
Considering EI range obtained by the results of both sensory test
and observation ratio on the contrast-detail phantom, it was indicated that
proper image quality would be given under EI range between 400 and 800. We
conclude that EIt and DI for chest X-ray image using DR system is 550 and -
1.5 to +1.5, respectively. In addition, this method is able to adapt for estimating
EIt and DI of various parts of X-ray images.
Author Disclosures:
S. Fujimoto: Research/Grant Support; Philips Electronics Japan, Ltd.
S164
B A C D E F G
Thursday
B-0133 10:48
The distribution of effective dose and its association with body mass
index and dose-area product in abdominal radiographic examinations
J. Jang, J.-H. Park, Y. Cho; Seoul/KR (
[email protected])
Purpose: To indentify the distribution of e ffective dose and its association with
body mass index (BMI) and dose area product (DAP) in abdominal
radiographic examinations.
Methods
and Materials: We analysed data from 57 patients undergoing
abdominal radiographic examinations in the supine and standing position. The
effective dose according to the weighting factor published in ICRP 103 was
calculated on the basis of patient information such as height, weight and
examination condition, including peak kilovoltage and focus-skin distance,
using a Monte Carlo program simulation. The Pearson correlation coefficient
and linear regression analysis were used to identify the correlation among
effective dose, BMI and DAP.
Results
The mean effective dose was 0.208 mSv and 0.273 mSv in the
supine and standing position, respectively. DAP correlated very well with
effective dose in the supine (r=0.973, R
2=0.946, p=0.000) and standing
position (r=0.991, R 2=0.982, p=0.000), respectively. BMI was also significantly
associated with effective does in the supine (r=0.821, R 2=0.675, p=0.000) and
standing position (r=0.806, R 2=0.649, p=0.000), respectively. The effective
dose tended to increase as BMI and DAP increased.
Conclusion
BMI and DAP have a large influence in effective dose. Therefore,
considering effective dose and its association with BMI and DAP, the use of
automatic exposure control (AEC) and condition of radiation exposure might be
controlled to prevent excessive dosage to patients with high BMI.
B-0134 10:57
10 kVp rule - an anthropomorphic pelvis phantom imaging study using a
CR system: impact on image quality and effective dose using AEC and
manual mode
L.J.O.C. Lanca
1, L. Franco2, A. Ahmed3, M. Harderwijk4, C. Marti2, S. Nasir3,
J. Ndlovu3, M. Oliveira1, A. Santiago1, P. Hogg3; 1Lisbon/PT, 2Lausanne/CH,
3Salford/UK, 4Groningen/NL (
[email protected])
Purpose: This study aims to investigate the influence of tube potential (kVp)
variation in relation to perceptual image quality and effective dose for pelvis
using automatic exposure control (AEC) and non-AEC in a computed
radiography (CR) system.
Methods
and Materials: To determine the effects of using AEC and non-AEC
by applying the 10 kVp rule in two experiments using an anthropomorphic
pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp)
for both experiments. The first experiment, based on seven AEC combinations,
produced 49 images. The mean mAs from each kVp increment were used as a
baseline for the second experiment producing 35 images. A total of 84 images
were produced and a panel of 5 experienced observers participated for the
image scoring using the 2 AFC visual grading software. PCXMC software was
used to estimate the effective dose.
Results
A decrease in perceptual image quality as the kVp increases was
observed both in non-AEC and AEC experiments, however no significant
statistical differences (p > 0.05) were found. Image quality scores from all
observers at 10 kVp increments for all mAs values using non-AEC mode
demonstrates a better score up to 90 kVp. Effective dose results show a
statistical significant decrease (p=0.000) on the 75
th quartile from 0.3 mSv at
60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC
mode.
Conclusion
No significant reduction in perceptual image quality is observed
when increasing kVp whilst a marked and significant effective dose reduction is
observed.
B-0135 11:06
Decision making and variation in radiation exposure factor selection by
radiographers: an eye-tracking study
S. Darcy, L.A. Rainford, R. Toomey; Dublin/IE (
[email protected])
Purpose: The goal of radiographic imaging is to produce a diagnostically
useful image while minimising patient radiation dose. This study aimed to
review variations in exposure factor sel ection by radiographers for virtual
patients with varying body mass index characteristics. Patient dose is impacted
upon by a number of exposure parameters including: kVp, mAs, source to
image receptor distance (SID) and anti-scatter grids.
Methods
and Materials: Eleven radiographers were asked to assign exposure
parameters (kVp; mAs; SID; grid) to forty computer-generated patient images,
which represented five BMI categories - underweight; healthy weight;
overweight; obese; super-obese. There were four examination categories:
antero-posterior (AP) shoulder; AP lumbar; lateral lumbar; AP ward chest. As
participants assigned exposures their visual patterns were recorded by a Tobii
® TX300 eye-tracker.
Results
Significant (p < 0.05) correlation was found between radiographer
age/experience and assignment of mAs for AP shoulder, and lumbar
examinations. Greater age/experience correlated with higher mAs for the AP
shoulder exam, but with lower values for lumbar examinations. Strong linear
correlation between times to first fi xations on relevant anatomical areas and
kVp/mAs values existed for the AP portable chest examination.
Conclusion
Exposure selection differences related to age/experience
highlight inconsistencies in the practice of exposure parameter setting. The
reasons for these inconsistencies requires further investigation, and how to
address deficiencies in practice requires consideration to optimise safe patient
care. Due to the small sample size used, further research into the relationship
between visual factors and individual examinations is suggested, following the
findings regarding the AP portable chest examination.
B-0136 11:15
An investigation into the impact of lead shielding application on
radiographic image quality during lumbar spine examination of obese
patients
J. Lowe, E. Cronin, L.A. Rainford; Dublin/IE (
[email protected])
Purpose: To determine whether the use of lead shielding (LS) aides in raising
image quality levels during lumbar spine examinations of clinically obese
patients.
Methods
and Materials: Antero-posterior and lateral lumbar-spine
radiographs were obtained an anthropomorphic phantom using a kVp range of
80-110 (projection dependant) with LS appli ed in clinically relevant positions.
The phantom was manipulated to achieve 'apple' and 'pear' body shaped body
habitus and obesity classes I and II status with application of pre-measured fat
packets. Diagnostic Imaging lecturers (n=3), with experience in visual grading
analysis (VGA), evaluated the phantom images (n=144), scoring CEC
anatomical criteria under controlled am bient lighting viewing conditions of 25-
40 lux. Images were displayed using Microsoft power-point on HPL1702
monitors. Statistical analysis of the mean image-quality scores (IQS) was
performed to determine if the position of LS and kVp levels influenced resultant
radiographic image quality.
Results
Findings indicated no significant impact on the IQS following
placement of LS for either body shape variations or obesity classes.
Radiographs obtained at the lowest kVp levels received the highest IQS. The
use of raised kVp levels from normal presets did not significantly impact upon
IQS with the exception of obesity class II images combined with the 'pear' body
shape which returned unacceptable VGA findings.
Conclusion
Results indicate that the use of LS did not influence image quality
during lumbar spine examinations of the obese phantom models. Optimal
image quality was identified following lower kVp application, however,
acceptable VGA findings were noted at higher kVp levels.
B-0137 11:24
Image quality and dose analysis in PA chest x-ray: comparison between
AEC and manual mode acquisition using the 10 kVp rule
C.S.D. Reis
1, J. Gonçalves1, C. Klompmaker2, A. Bárbara1, C. Bloor3,
R. Hegarty3, T. Lagrange4, N. Temming2, M. Sønnesyn5, H. Røkeness5,
A. Yamasathien4, P. Hogg3; 1Lisbon/PT, 2Groningen/NL, 3Salford/UK,
4Lausanne/CH, 5Oslo/NO (
[email protected])
Purpose: To compare image quality and effective dose when the 10 kVp rule
is applied with manual and AEC mode in PA chest X-ray.
Methods
and Materials: A total of 68 images (with and without lesions) were
acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray
unit. The images were evaluated against a reference image using image
quality criteria and the 2 alternative forced choice (2 AFC) method by five
radiographers. The effective dose was calculated using PCXMC software using
the exposure parameters and DAP. The exposure index (lgM) was recorded.
Results
Exposure time decreases considerably when applying the 10 kVp
rule in manual mode (50%-28%) compared to AEC mode (36%-23%).
Statistical differences for effective dose between several AEC modes were
found (p=0.002). The effective dose is lower when using only the right AEC
ionization chamber. Considering image quality, there are no statistical
differences (p=0.348) between the different AEC modes for images with no
lesions. Using a higher kVp value the lgM values will also increase. The lgM
values showed significant statistical differences (p=0.000). The image quality
scores did not present statistically significant differences (p=0.043) for the
images with lesions when comparing manual with AEC modes.
Conclusion
In general, the dose is lower in the manual mode. By using the
right AEC ionising chamber the effective dose will be the lowest in comparison
to other ionising chambers. The use of the 10 kVp rule did not affect the
detectability of the lesions.
S165
B A C D E F G
Thursday
B-0138 11:33
Dose reduction with PA projection in sacroiliac joint imaging
N. Mekiš; Ljubljana/SI
Purpose: To investigate the impact of the PA projection instead of the
standard AP projection for sacroiliac joint (SIJ) imaging on the entrance skin
dose (ESD), testicular dose and image quality.
Methods
and Materials: The study was conducted both, on an
anthropomorphic phantom and on 50 male patients, randomly divided into two
equal groups. In the first group the SIJ imaging was conducted in the AP
projection, whereas in the second group the imaging was conducted in the PA
projection. The dose was measured by thermoluminescent dosimeters (TLD)
placed at the centre of the image field and on the testicles. Image quality
evaluation by using CEC anatomical structure scoring was performed by two
radiologists and by three senior radiographers.
Results
When using the PA projection the ESD was reduced from
7.01±3.59 mGy to 5.21± 2.57 mGy (p=0.046). The testicular dose was reduced
from 27.92 ±22.07 Gy to 5.64 ±4.26 Gy (p < 0.001). However, the image
quality was better in the AP projection (p=0.012).
Conclusion
The results have shown that the ESD and testicular dose in SIJ
imaging were lower in PA projection. The image quality performed on patient
imaging was lower in PA projection compared to the AP projection, but they
could still be used for diagnostics. Therefore the PA projection can be
recommended as a method of choice in SIJ imaging.
B-0139 11:42
The effect of breast shielding in panoramic dental imaging
N. Mekiš, N. Dovear; Ljubljana/SI
Purpose: To investigate the impact of lead shielding and its position on breast
dose in adult panoramic dental imaging.
Methods
and Materials: The study was conducted on an anthropomorphic
phantom. The breasts were simulated by breast implants of two different sizes
340 ml and 500 ml. Shield coat and gonadal apron of 0.5 mm lead equivalent
were used. The measurements were performed without the use of lead
shielding and then with three different positions of shielding: coat for the whole
body, gonad apron at the rear of the phantom and gonad apron at the front of
the phantom. The dose was measured by EDD-30 placed at the centre of the
breast, on the top of the breast and on the top of the lungs.
Results
Using the lead coat shielding reduced the dose at the centre of the
right breast (500 ml) from 2.3 8Gy to 0.6 Gy and the dose at the centre of left
breast (340 ml) from 2 8Gy to 0.2 8Gy. Dose reduction to the breasts when
using gonadal apron at the back of the phantom was on average 1% and an
average of 70% was achieved when using it at the front. The dose reduction at
the top of the lungs was from 20.5 8Gy to 1.6 8Gy when the lead coat shielding
was used.
Conclusion
Based on the results, we can conclude that the use of coat lead
shielding is recommended in the panoramic dental radiography. Despite the
low-dose exposure even without shielding, the dose can be further reduced.
B-0140 11:51
Variation of lumbar and pelvis Agfa exposure index in different
radiography equipment's
R. Lopes
1, J. Santos2; 1Vila Nova de Foz Côa/PT, 2Coimbra/PT
(
[email protected])
Purpose: The exposure index (EI) is a useful tool to estimate patient dose
based on detector exposure. Agfa systems described EI as logarithmic value
(IgM), that corresponds to 1.96 bels in standard Speed Class. The increase of
0.3 in lgM value corresponds to twice of the detected dose. The aim of this
study was analyse the Agfa exposure index variation during lumbar and pelvis
radiographies.
Methods
and Materials: Random anthropomorphic phantom was exposed to
lumbar (frontal and lateral view) and pelvis radiographies in ten different
centres. Experimental test with exposure parameters according to the
recommendations were performed, with and without automatic exposure
control (AEC). Unfors Patient Skin Dosimeter (PSD) was used to quantify
patient dose and lgM was directly obtained on Agfa workstations.
Results
The lgM mean value with AEC was 1.90 bels with mean patient dose
of 75.15Sv and without AEC was 2.06 bels with 68.68 Sv. For lumbar frontal
and lateral view, with the same exposure parameters, the major lgM value
differences were 27% and 33%, respectively. For pelvis the major difference
was 29%. Despite lgM variation the PSD obtained values per body region were
similar across the centres.
Conclusion
The lgM value revealed a large variation during lumbar and pelvis
exposures in different radiography equipment's.
10:30 - 12:00 Room P
Computer Applications
SS 105
Trends in reporting, image managment
and mobile computing
Moderators:
U.W. Engelmann; Dossenheim/DE
A. Simisker; Tartu/EE
B-0141 10:30
First experience with a novel time-saving method for automatic labelling
and curved multiplanar reconstructions for spinal CT
J.-E. Scholtz, J.L. Wichmann, M. Kaup, C. Frellesen, M. Beeres, T. Lehnert,
T.J. Vogl, J. Kerl, R.W. Bauer; Frankfurt a. Main/DE (
[email protected])
Purpose: To evaluate a novel method for automatic labeling and curved
multiplanar reconstructions of spinal CT and to investigate its potential for time
savings and workflow improvement.
Methods
and Materials: 77 patients (28 women, 49 men, mean age
65.3±14.4 years) with known spinal disease including degenerative changes of
neuroforamina or spinal canal (n=32), disc herniation (n=36) or traumatic
vertebral fractures (n=9) were examined usi ng 64-slice MDCT. Required time
for automatic labeling and curved multiplanar reconstructions of the examined
vertebral column was compared with manual reconstructions. Error rate and
additional time for manual error correction during automatic labelling was
assessed. Both curved multiplanar reconstructions were assessed by two
observers regarding evaluation of anatomical structures.
Results
Correct automatic labelling was achieved in 72 patients (93.5%) with
an error rate of 6.5% (n=5), which could be manually corrected in all cases
within 16.0 ±6.6 seconds. Automatic processing of the whole vertebral column
was significantly faster (p < 0.05) than manual reconstruction (266.3 ±6.8
seconds vs. 286.7 ±9.7 seconds, p < 0.05). Automatic reconstructions were
preferred by both observers in 52 cases (67.5%). In 25 cases (32.5%), both
observers stated that both reconstruction methods allowed an equally good
evaluation of anatomical structures of the spine. There was no interobserver
disagreement.
Conclusion
The presented automatic labelling and curved multiplanar
reconstruction method for evaluation of vertebral column CT is time saving and
might improve the workflow in routine clinical practice as it rarely requires
manual adjustment. Furthermore, automated curved reconstructions were
preferred in 2/3 of cases and potentially facilitate evaluation of spinal anatomic
structures.
Author Disclosures:
J. Kerl: Speaker; Siemens Healthcare, CT Division. R.W. Bauer: Speaker;
Siemens Healthcare, CT Division.
B-0142 10:39
Optimising RECIST reading using dedicated software
A. René1, S. Aufort2, S. Si Mohamed2, B. Gallix1; 1Montpellier/FR,
2Castelnau-Le-Lez/FR (
[email protected])
Purpose: The purpose of the study was to evaluate the reading time and
reliability improvement using dedicated oncology software in comparison with
manual determination of RECIST response.
Methods
and Materials: 40 patients who underwent a CT-scan follow-up have
been evaluated according to RECIST criteria using a standard viewer and
dedicated software with 3D elastic targ et matching and automatic calculation of
tumoral response (Myrian® XL-Onco, Intrasense). The medical database
contained thoracic and abdominal images. Readings were performed by two
operators both with distinct degrees of experience. Reading times, inter and
intra-operator reproducibility of measurements and response misclassifications
(PD, SD, PR, CR) were evaluated.
Results
Reading times and reproducibility were not affected by the operator
degree of experience. In average, the reading time was reduced by 49.7%
using dedicated software (mean manual reading time: 106.3 sec., mean
software reading time: 50.2 sec., p < 0.05). When stratifying results by target
localisation, the decrease in reading time was 36.1% for hepatic targets (mean
target size: 45.5 mm) and 63.4% for pulmonary targets (mean target size:
18.7 mm). Inter and intra-operator reproducibility of measurements according
to each method was identical (r=0.99). Using dedicated software prevented
from misclassifications on 10 readings out of 120 (8 were due to calculation
errors).
S166
B A C D E F G
Thursday
Conclusion
The use of dedicated oncology software optimises RECIST
evaluation, decreasing significant ly reading times and response
misclassifications.
Author Disclosures:
A. René: Employee; Intrasense Employee (CIFRE).
B-0143 10:48
RECIST management at investigator sites: evaluation of a cloud-based
quality control of imaging evaluations in clinical trials
N. Sueoka-Aragane1, N. Kobayashi1, E. Bonnard2, C. Charbonnier3, E. Oubel3,
J. Yamamichi4, H. Mizobe4, S. Kimura1; 1Saga/JP, 2Nice/FR, 3Valbonne/FR,
4Tokyo/JP (
[email protected])
Purpose: Imaging evaluation in oncology depends on readers performances.
In order to standardise RECIST (Response Evaluation Criteria in Solid Tumors)
application at investigator sites, this study tested a cloud-based quality control
of response evaluations.
Methods
and Materials: 11 cancer patients with chest CT scans available at 3
time points were retrospectively selected. Images were reviewed following
RECIST 1.1 criteria by two oncologists (Japan and Scotland) and one
radiologist (France). They used cloud solutions (MEDIAN Technologies)
hosted by a data center (Canon, Japan) ensuring centralisation and quality
control of both images and evaluations. A quality control of evaluations
consisted for the radiologist in checking
oncologists' baseline evaluation and establishing a consensus for the choice of
target lesions. The impact of this consensus was analysed by measuring the
mean inter-observer agreement on evaluations.
Results
The agreement rate between the oncologists and the radiologist for
the target lesions choice increased from 59% (13/22 baselines) to 82% (18/22)
before and after consensus. Justifiable differences in images interpretation
prevented from having 100%. An agreement rate of 82% (36/44 evaluations)
was observed for response evaluations before and after consensus. The rate
was higher than in a previous pilot study without consensus (40%, 8/20). The
quality control solved all non-conformities to RECIST (18%, 4/22 baselines).
Conclusion
The study shows the feasibility of a cloud-based quality control of
imaging evaluations in multi-center international clinical studies that ensured
100% of compliance with RECIST criteria. An improved agreement in the
choice of target lesions was accomplished in conformity to RECIST.
B-0144 10:57
Mobile DICOM viewing applications facilitate multicenter radiology
I. Reicht, D. Simons, M. Fangerau, H.-P. Meinzer, A. Sassenberg, K. Yen,
H.-P. Schlemmer; Heidelberg/DE (
[email protected])
Purpose: Mobile communication via tablet devices and smartphones has
increasingly entered the healthcare sector. Continuous improvements in the
resolution of tablet devices have made them interesting for radiological image
viewing. However, integrating mobile applications into radiological workflows is
difficult since major investments for extending IT infrastructure are often
required. Here we introduce an economical approach to easily integrate
radiological infrastructures, facilitate multicenter networking and establish a
sophisticated base for target-oriented procedures of forensic medicine based
on mobile applications.
Methods
and Materials: Feasibility of integrating the CT infrastructure of the
Institute of Forensic Medicine, University of Heidelberg, and the Department of
Radiology, German Cancer Research Center (DKFZ), Heidelberg was
evaluated with a forensic-radiological workflow. This included acquiring CT
images, radiologists viewing images to generate pre-reports and furthermore
forensic pathologists viewing images al ong with radiologists' pre-reports at
autopsy. To view and access images the application MITKpocket, developed
by the Department of Medical and Biological Informatics at DKFZ, was used
which allows offline image processing on tablet computers.
Results
Inter-department communication in the case of forensic imaging
purposes was facilitated. The CT infrastructures were integrated by virtual
private network (VPN) while MITKpocket supported radiologists and
pathologists to access and process images. Hence no cost-intensive
investments to extend modify and maintain the previously existing radiological
infrastructures were needed.
Conclusion
A practical approach to integrate mobile radiological applications
into multicenter workflows was best achieved by offline capable applications of
teleradiology. Even limitations of wireless IT infrastructure could be fully
compensated within the forensic-radiological workflow.
B-0145 11:06
DICOM-SandBox, an open communication platform for collaborative
research
N. Roduit, T. Strgar, O. Ratib; Geneva/CH
Purpose: The goal of our project is to develop a secure portal for exchange of
large sets of medical images between professionals. Unlike existing DICOM-
based teleradiology systems intended for clinical data, we elected to design an
open system that allows researchers to exchange anonymised image data in a
decentralised peer-to-peer architecture based on social networking paradigm.
This project is an exploratory initiative of the ESR eHealth and informatics
subcommittee.
Methods
and Materials: The file exchange platform was developed around an
Open Source framework called "ownCloud" (www.owncloud.org), allowing
universal data and file exchange through web interface or WebDav that
enables users to use existing cloud-based storage services though a single
portal. The system handles the management of social networks of a
community of users supporting notificati on and data exchange between users
or groups. The open "plug-in" architecture allowed us to extend its
functionalities with specific features for management and display of DICOM
files. Hierarchical storage and thumbnail preview of image series are part of
the added features. Special interface modules were developed for seamless
integration of existing Open-Source DICOM viewers including OsiriX and
Weasis (www.osirixviewer.com). The system relies on existing cloud-storage
services such as DropBox and Google drive, allowing each user to use his own
storage service.
Results
A prototype system was developed and tested among different
academic institutions for exchange and communication of anonymous DICOM
files.
Conclusion
The DICOM-SandBox system provides an Open-Source solution
for convenient and efficient exchange and communication of DICOM files
among academic and research teams.
B-0146 11:15
Comparison of a tablet-PC with a high-resolution display and a dedicated
PACS worsktation in emergency MDCT interpretation
S. Tewes, T. Rodt, S. Marquardt, E. Evangelidou, F. Wacker, C. von Falck;
Hannover/DE (
[email protected])
Purpose: To compare a tablet-PC with a high-resolution display (iPad 3) and a
dedicated 3D PACS workstation for the interpretation of emergency CT
examinations
Methods
and Materials: The detectability of early signs of cerebral infarction
and subtle pulmonary embolism in 40 CCT and 40 CTPA examinations was
scored by three readers using both, a tablet-PC with a high-resolution display
(iPad 3, Apple Inc., USA) running a radiology app (Visage Ease, Visage
Imaging GmbH, Berlin, Germany) and a 3D PACS workstation (Visage 7.1,
Visage Imaging GmbH, Berlin). Diagnostic confidence was evaluated on a 5-
point-Likert scale. Statistics included Wilcoxon rangsum test, Spearman's
correlation and Cohen's kappa.
Results
For all readers, there was no significant difference in the median
score between iPad 3 and PACS for the CCT and the CTPA, respectively
(p> 0.05). The mean Spearman's correlation coefficients were 0.46 ( ±0.2) /
0.69 (±0.16) for the comparison between the iPad and the PACS, 0.41 ( ±0.16) /
0.68 ( ±0.06) for observer agreement using the iPad and 0.35 (± 0.05) / 0.68
(±0.10) for observer agreement using the PACS for CCT and CTPA,
respectively. Mean kappa values were 0.52 ( ±0.17) / 0.67 ( ±0.19) for the
comparison between iPad and PACS, 0.33 ( ±0.16) / 0.69 ( ±0.08) for observer
agreement using the iPad and 0.32 (± 0.16) / 0.60 ( ±0.14) for observer
agreement using PACS. The differences were not considered statistically
significant (p> 0.05)
Conclusion
There is no significant difference from interobserver agreement in
the interpretation of typical emergency CT examinations between the iPad 3
and a dedicated PACS workstation.
Author Disclosures:
T. Rodt: Research/Grant Support; Visage Imaging. F. Wacker:
Research/Grant Support; Visage Imaging, Siemens Healthcare. C. von Falck:
Research/Grant Support; Visage Imaging, Siemens Healthcare.
S167
B A C D E F G
Thursday
B-0147 11:24
Quality control in radiology reporting: experience in a private setting
T. Laswad1, D. Fournier1, H. Brat1, M. Deac2, O. Deriaz1; 1Sion/CH,
2Morges/CH (
[email protected])
Purpose: The aim of this study is to set up quality criteria of our radiology
reports, to present a quality control model for reporting, to identify the most
frequent errors in our reporting and to suggest corrective actions of
improvement.
Methods
and Materials: 32 quality criteria of radiology reports have been
defined and adapted by the radiologists in a group of private clinics covering
the main imaging modalities. Five pairs of radiologists evaluated 250 structured
anonymous reports independently. A consensual review and discussion was
performed for all reports foor both analytical and educational purpose. A
scoring system of the various criteria was made to depict the weak points in
the reports. We only studied the reports, not the imaging details.
Results
We identified our most frequent reporting errors (global and individual
analysis). The most frequent reporting errors were: wrong study title, unclear
indication, vague conclusion and not answering the clinician's question. We set
up a pertinent checklist of quality criteria of our structured reports. We present
typical examples of conformity, consistency and the most frequent errors in
reporting. This project enhanced the aware ness of radiologists about their most
frequent reporting errors. Peer review was appreciated by radiologists as it
helps to share knowledge.
Conclusion
Improvement of the quality of the report depends mainly on the
awareness and involvement of radiologists to apply quality standards. Quality
improvement of structured reporting must be a continuous process of
correction and implementation (continuous quality improvement principle).
B-0148 11:33
iPad-based primary 2D reading of CT angiography examinations of
patients with suspected gastrointestinal bleeding: performance
comparison with a conventional workstation
L. Faggioni
1, E. Neri1, I. Bargellini1, P. Scalise1, F. Calcagni1, G. D'Ippolito2,
C. Bartolozzi1; 1Pisa/IT, 2São Paulo/BR (
[email protected])
Purpose: To evaluate the effectiveness of the iPad for 2D reading of CT
angiography studies performed for suspected acute gastrointestinal bleeding.
Methods
and Materials: Twenty-five CT angiography (CTA) examinations of
patients with suspected acute gastrointestinal bleeding either confirmed (20/25,
80%) or ruled out (5/25, 20%) by digital subtraction angiography (DSA) were
retrospectively reviewed by four independent readers. Two readers evaluated
source axial CTA images on a commercial workstation (Advantage Windows
4.5, General Electric, Milwaukee, WI), whereas the others assessed the same
images on an iPad with Retina Display™ (64GB model, Apple Inc, Cupertino,
CA). All CTA images had been wirelessly transferred on the iPad in JPEG
lossless format using the Bonjour™ protocol. The time needed to complete
reading of every CTA examination on the iPad and the workstation, detection
of arterial blush, and suspected bleeding arteries as assessed on both devices
were recorded.
Results
The time needed to complete reading of every CTA study was
significantly shorter on the iPad than on the workstation (171 ±84 vs 227 ±91
seconds, respectively; p < 0.002). Sensitivity and specificity for arterial blush
detection were 85% and 60% for the workstation and 90% and 80% for the
iPad, respectively. Inter-reader agreement for workstations and iPads was
good (Cohen k=0.70) and very good (k=0.88), respectively. Agreement of
workstation and iPad vs DSA on bleeding arteries was very good (k=0.82 and
0.89, respectively).
Conclusion
iPad-based preliminary 2D reading of CT angiography studies of
patients with suspected acute gastrointe stinal bleeding is feasible and
significantly faster compared with a conventional workstation.
B-0149 11:42
Adaptive support for PACS interface customization
W. Jorritsma, F. Cnossen, P.M.A. van Ooijen; Groningen/NL
(
[email protected])
Purpose: To evaluate the usefulness of adaptive customization support in the
Picture Archiving and Communication System (PACS) user interface.
Methods
and Materials: Adaptive support was given in the form of
customization suggestions, generated based on behavioural user data, which
participants could choose to accept or ignore. Twelve radiologists worked with
the standard adaptable version of the PACS for six weeks, during which their
actions on the PACS interface were logged. Based on these logging data,
customization suggestions were generated for each specific participant. Half of
the participants received these suggestions and half did not. After the
suggestions, logging continued for another six weeks. Participants'
customization behaviour and performance, measured as the average time
needed to review a radiography study, were compared between the groups.
Subjective responses to the customization process were also measured.
Results
Participants accepted most of the customization suggestions and all
participants indicated that the suggesti ons were useful. Participants who
received customization suggestions used the customizable elements of the
PACS's interface more frequently than participants who did not receive the
suggestions. There were no effects in the performance data, possibly because
the performance measure we used was not sensitive enough. Subjective
responses did show that participants judged the adaptive support as improving
their efficiency.
Conclusion
Adaptive customization support is a valuable addition to the
standard adaptable PACS interface, because it allows radiologists to
customize their interface more effectively and can thereby increase the
efficiency with which they interact with the PACS.
B-0150 11:51
Web-based interactive 3D visualisation of CT image data on tablet
computers for educational purposes
R. Unterhinninghofen1, S. Doll2, F. Rengier2, R. Talanow2, J. Kirsch2,
R. Dillmann1, H.-U. Kauczor2, F.L. Giesel2; 1Karlsruhe/DE,
2Heidelberg/DE (
[email protected])
Purpose: Volume rendering of CT image data is a 3D visualisation technique
well known from commercial workstations where it supports diagnostics and
therapy planning. In order to render these appealing views available for
educational purposes, we developed dedicated software solution
AnatomyMap.
Methods
and Materials: Since tablet computers usually do not provide
sufficient computational power to render 3D visualisation at interactive rates,
we created a client-server solution based on in-house developed software
framework MEDIFRAME. A high-performance server performs rendering on
demand and streams the resulting views via internet to the client, e.g. a tablet
computer. Users find a common display with 2D and 3D views of the CT data
that may be scrolled, rotated, zoomed, or panned interactively. For educational
purposes labels may be displayed for selected anatomical structures. Also, for
each structure an appropriate view is predefined that can be reached in an
animated flight. In exercise mode users assign names to empty labels using
drag and drop.
Results
30 CT datasets of different body parts, including head, neck, thorax,
abdomen, and extremities were manually labelled with (normal) anatomical
structures. Additionally, 12 CT datasets we re labelled with specific pathological
structures. The software has been experimentally used in an online course with
10 users located at different places in Europe. All users were able to run the
web-based software and perform the required exercises. Depending on
individual internet bandwidth overall experience with interactive rendering was
good.
Conclusion
AnatomyMap has been found a prac ticable tool and motivating
extension to the anatomical atlas.
14:00 - 15:30 Room B
Abdominal Viscera
SS 201a
Advanced imaging of pancreas
Moderators:
L. Grzycka-Kowalczyk; Lublin/PL
C. Triantopoulou; Athens/GR
B-0151 14:00
Incidental hypervascular pancreatic lesions: prevalence and imaging
features on MDCT
P. Allegranza, D. Ippolito, F. Leone, P.A. Bonaffini, S. Sironi; Monza/IT
(
[email protected])
Purpose: To assess frequency of hypervascular pancreatic lesions (HPL)
incidentally detected on multidetector CT (MDCT) and to evaluate
morphological features that can allow their characterisation.
Methods
and Materials: From August 2012 to February 2013, we
retrospectively reviewed on the Institution's electronic database 3827
consecutively contrast-enhanced abdominal MDCT performed both on a 256
(iCT, Philips) or 16-row CT scanner (Brilliance, Philips). The inclusion criterion
was the incidental detection of hypervascular pancreatic lesions in patients
with no symptoms related to the lesion itself. We evaluated several CT findings
including lesion location, size, morphol ogy, presence of calcification and
vascular pattern. Then, we correlated imaging findings with available clinical
data.
Results
We detected 28 solid HPL (prevalence 0.4%) in 14 patients (9 male,
5 female; age range 67-83, mean 76). Sizes ranged from 3 to 58 mm, (mean
13 mm; median 9 mm); most common site of the lesion was the pancreatic tail
S168
B A C D E F G
Thursday
(11/28). A final diagnosis was reached in all cases by medical history or
histopathological analysis: pancreatic neuroendocrine tumour (11/28),
intrapancreatic accessory spleen (1/28), and renal cell tumour (RCC)
metastases (16/28). Main pancreatic duct obstruction without parenchymal
atrophy was found in 1 patient (RCC lesion). Symptoms were present in 2/14
(14%) patients; reported symptoms were SIADH (1 case) and abdominal pain
(1 case). Dimensional growth during follow-up was observed in 21/28 cases
(16/21 were RCC multiple pancreatic metastases).
Conclusion
Incidental HPL are uncommon findings on MDCT. When multiple
lesions are present, MEN I syndrome and presence of RCC should be
considered.
B-0152 14:09
Diagnostic accuracy of 256-detector row computed tomography in
detection and characterisation of incidental pancreatic cystic lesions: a
large population series
P. Allegranza, D. Ippolito, P. Bonaffini, F. Leone, D. Fior, A. Casiraghi,
S. Sironi; Monza/IT (
[email protected])
Purpose: To assess the diagnostic value of 256-detector row MDCT in
characterisation of incidentally detected pancreatic cystic lesions in a large
population of patients.
Methods
and Materials: We retrospectively reviewed 6389 examinations
performed on a 256-row detector scanner (iCT, Philips, 120 kV, automated
current modulation) between January 2011 and February 2013 for incidental
detection of pancreatic cysts. 192 patients (99 females, 93 males; age range
31-90) were enrolled. Images were evaluated by two radiologists referring to
standardised morphologic features and predictive signs of malignancy: lesion's
location, multifocality, size, communication with main pancreatic duct (MPD),
MPD size, inner septa, wall thickening and mural enhancing nodules.
Results
We evaluated 292 cysts in 192 patients (prevalence 2.05%).
Diagnosis was established by histopathology or by imaging analysis: solitary
branch type IPMN (48.4%), multifocal branch-type IPMN (14.1%), main type
IPMN (13%), mixed IPMN (10.4%), pseudocysts (2.6%), mucinous (7.3%) and
serous cystoadenoma (3.7%), metastases (0.5%). Solitary cysts were found in
145/192 (75.5%), two lesions in 27/192 (14.1%) and more than two in 20/192
patients (10.4%). Size ranged from 3 to 145 mm (mean 15 mm); lesions were
mostly located in pancreatic body (87/292; 29.8%). We detected septa in
52/292 lesions, wall thickening > 2 mm in 13/292, wall enhancement in 15/292,
mural enhancing nodules in 12/292, communication with ductal system in
25/292 and MPD dilatation in 10/292.
Conclusion
MDCT provide important diagnostic features for characterisation
of pancreatic cystic lesions, incidentally discovered with increased frequency
due to the widespread use of cross-sectional imaging.
B-0153 14:18
Effect of incidental pancreatic cystic lesions on all-cause mortality and
incidence of pancreatic adenocarcinoma and ductal carcinoma
V. Chernyak, M. Flusberg, L. Haramati, A.M. Rozenblit, E. Bellin; Bronx,
NY/US (
[email protected])
Purpose: To assess effect of incidental pancreatic cysts (IPC) on all-cause
mortality and incidence of pancreatic adenocarcinoma (AdenoCA) and
pancreatic ductal carcinoma (DCA).
Methods
and Materials: Cyst cohort included cases with CT/MR reports done
between 11/1/01 and 11/1/11 describing IPC. No-cyst cohort was frequency-
matched on age decade, modality and year of initial study from pool of patients
without reported IPC. Cases diagnosed with pancreatic cancer within 5 years
of initial CT/MR were excluded. Charlson 2 scores within 2 months of index
date were recorded. 10-year cumulative mortality and 10-year cumulative
incidence of AdenoCA/ DCA were compared between the cohorts. Cox Hazard
models were constructed with all-cause mortality and incidence of
AdenoCA/DCA as outcome events, adjusting for age, sex, imaging modality
and Charlson 2 score.
Results
There were 1,337 cases in Cyst cohort and 3,993 cases in No-cyst
cohort with mean age of 70.6 (± 15.4) and 70.0 ( ±15.6) years, respectively
(p=0.304). 10-year cumulative all-cause mortality was 13.0% (95% CI 10.2-
16.5) in Cyst cohort and 11.7% (95% CI 10.1-13.4) in No-cyst cohort. 10-year
cumulative incidences of AdenoCA/DCA were 1.6% (95% CI 0.8-3.3) in Cyst
cohort and 0.3% (95% CI 0.1-0.6) in No-cyst cohort (p < 0.001). For all-cause
mortality, IPC had HR of 1.74 (95%CI 1.14-2.64) in subjects < 70 years and HR
of 0.9 (95% CI 0.69-1.18) in those 70 years. For AdenoCA/DCA, IPC had HR
of 4.22 (95%CI 1.65-10.8).
Conclusion
Incidental pancreatic cysts on CT/MR are associated with 4.2
times higher risk of pancreatic AdenoCA /DCA and with 1.7 times higher all-
cause mortality in subjects < 70 years.
B-0154 14:27
Arterial hypervascular solid-looking serous cystadenoma of the
pancreas: differential diagnosis with neuroendocrine tumours
H. Park, S. Kim, S. Park, S.-M. Hong, S. Lee, J. Byun, J. Kim, H. Kim,
M.-G. Lee; Seoul/KR (
[email protected])
Purpose: To describe imaging findings of arterial hypervascular solid-looking
serous cystadenoma (SCN) of the pancreas on CT and MR and to find imaging
features which differentiate it from neuroendocrine tumour (NET).
Methods
and Materials: Among 211 patients with surgically proven SCNs, we
retrospectively identified 15 arterial hypervascular solid-looking SCNs. We
randomly chose size-matched 30 NETs from 80 pancreatic NETs. Two
radiologists evaluated available CT and MR images in consensus. On CT, the
reviewers assessed the size, location, shape, margin, CT attenuation and
enhancement grade relative to the adjacent pancreatic parenchyma on the
non-enhanced and dynamic phases. On MR, signal intensity characteristics of
the tumour on T1-, T2-weighted images and ADC maps were evaluated. These
features and measurements were compared using the Fisher exact test and
the Mann-whitney test.
Results
The frequency of arterial hypervascular solid-looking SCNs was 5.1%
amongst all SCNs. The mean size was 25.8 mm (range, 8.4-80 mm). CT
findings were similar between the two tumours: location, shape, margin, and
enhancement patterns the dynamic phases. However, SCNs were significantly
hypodense on non-contrast CT images than NETs (P=.03). They differed
significantly on MR: bright signal intensity on T2-weighted images were more
common in SCNs than NETs (P=01). All SCNs showed restricted diffusion on
ADC map, while none of NETs did (P <.01).
Conclusion
It is often difficult to differentiate arterial hypervascular solid-
looking SCNs from NETs, since they share similar imaging features.
Hypoattenuation on non-contrast CT images, bright signal intensity on T2-
weighted MR images, and diffusion restriction can facilitate the differentiation.
B-0155 14:36
Added value of diffusion-weighted imaging to conventional MR imaging
in the preoperative detection of small pancreatic carcinoma
S. Kwon, Y. Kim, D. Choi, W. Lee, W.-K. Jeong, J. Min, M. Cha, C. Jeong;
Seoul/KR (
[email protected])
Purpose: To evaluate the benefit of adding diffusion-weighted (DW) imaging
into the conventional MR imaging in the preoperative detection of small
pancreatic carcinoma ( 2.0 cm).
Methods
and Materials: The study included 83 patients (56 men, 27 women)
with surgically confirmed pancreatic adenocarcinoma (n= 53 2.0 cm; n=30
2.1-3.0 cm) and 12 patients with histologi cally proven focal pancreatitis who
underwent gadoxetic acid-enhanced MR imaging and DW imaging between
August 2010 and November 2012. Two observers independently reviewed two
image sets: 1) conventional MR imaging set including MR
cholangiopancreatography and 2) combined image set including DW imaging
to evaluate the circumferential tumour conspicuity using receiver operating
characteristic curve analysis. Contrast ratios of each tumour and proximal or
distal pancreatic parenchyma to tumour on T1- and T2-weighted image, arterial
and portal phase, and b-800 DW imaging were also calculated.
Results
On b-800 DW imaging, most tumours were completely (n=32, 38.6%)
or partially (n= 59.0%) delineated. For each observer, A
Z values for tumour
detection were 0.852 and 0.884 for the conventional image set, and 0.975 and
0.978 for the combined set (P =0.003; 0.04). For detecting 53 tumours (
2.0 cm), the combined set (96.2%[51/53]; 94.3%[50/53]) yielded better
sensitivity than the conventional image set (67.9%[36/53]; 71.7%[38/53])
(P=0.001; P=0.008), although no significant difference was found between the
two image sets for detecting tumour > 2.0 cm ( P> 0.05). Contrast ratio of
tumour on b-800 image was significantly higher than those of other images
(P
< 0.0001).
Conclusion
In preoperative evaluation of small pancreatic adenocarcinoma,
the addition of DW imaging to the conventional MR-imaging could improve
sensitivity in tumour detection.
B-0156 14:45
Comparison of 320-row perfusion CT-angiography with endoscopic
sonography in preoperative diagnostic of isulinomas
E. Mukhamatullina, S. Kondrashin, S. Ternovoy; Moscow/RU
(
[email protected])
Purpose: To compare the accuracy of preoperative detection of insulinomas
between perfusion CT-angiography and endoscopic sonography.
Methods
and Materials: A total of 90 patients, main group 45 patients with
specific clinical symptoms and Wipple's tri ad and control group of 45 patients
(43.4± 2.8 years) underwent perfusion CT-angiography. Endoscopic
sonography was performed for main group of patients. Patients were scanned
on 320-detector row CT scanner with following parameters: dynamic volume
scan mode, gantry rotation 0.5 sec, scan coverage 10-16 cm, tube voltage
S169
B A C D E F G
Thursday
100 kV and tube current 150 mA, slice thickness 0.5x320 mm. IV injection of
60 ml contrast media (320-350 mgI/ml) with flow rate of 5 ml/s was used. The
protocol for dynamic pancreas-imaging consisted of 19 intermittent images.
Image datasets were reconstructed with 0.5-mm slice thickness and a total of
6,400 images for the entire examination. Analysis of dynamic pancreas images
was performed in MPR, MIP projections using 4D cine mode. Respiratory
misregistrations were compensated with the software. Perfusion was
determined with the gradient relationship technique. Contrast time-density
curves and perfusion maps were generated.
Results
Endoscopic sonography was performed in 45 patients and allowed
correct localisation of 50/ 66 tumours. Detection rate of perfusion angiography
was higher than for endoscopic sonography 61/66 (92.4%). Arterial flow was
raised in patients with isulinoma in normal parenchyma comparing to control
group (p < 0.05).
Conclusion
320-row perfusion CT-angiography significantly improves
diagnostic confidence as compared to endoscopic sonography. Perfusion
imaging carries the potential to improv e detection of insulinomas due to the
significant perfusion differences.
B-0157 14:54
Pancreatic neuroendocrine tumours: correlation between histogram
analysis of apparent diffusion coefficient MRI maps and tumour grade
J. Sousa Pereira1, E. Rosado2, M.A. Bali3, T. Metens3, S.-L. Chao3,
P. Demetter3, C. Matos3; 1Lisbon/PT, 2Amadora/PT, 3Brussels/BE
(
[email protected])
Purpose: To explore the role of histogram analysis of apparent diffusion
coefficient (ADC) MRI maps based on entire tumour volume data in
determining pancreatic neuroendocrine tumour (PNT) grade.
Methods
and Materials: Retrospective evaluation of 22 patients with PNTs,
including low-grade (G1; n=15), intermediate-grade (G2; n=4) and high-grade
(G3; n=3) tumours. Regions of interest containing the lesion were drawn on
every section of the ADC map containing the tumour and summated to obtain
histograms for entire tumour volume. Calculated histographic parameters
included mean ADC (mADC), 5
th percentile ADC (ADC5), 10 th percentile ADC
(ADC10), 25 th percentile ADC (ADC25), 50 th percentile ADC (ADC50), 75 th
percentile ADC (ADC75), 90 th percentile ADC (ADC90) and 95 th percentile
ADC (ADC95), skewness and kurtosis. Histogram parameters were correlated
with tumour grade by repeated measures analysis of variance with Tukey-
Kramer post hoc comparisons.
Results
The mADC, ADC75, ADC90 and ADC95 were significantly higher in
G1 tumours (1283± 267; 1404 ±300; 1495 ±318; 1562 ±347 x 10-6 mm2/s)
compared to G2 (892 ±390; 952±381; 1036±384; 1072±374 x 10-6 mm2/s) and
to G3 tumours (733± 225; 864± 284; 1008± 288; 1152 ±192 x 10-6 mm2/s) (p-
value< 0.05). Skewness and kurtosis were significantly different between G1
(0.041±0.466; 2.802± 0.679) and G3 (1.01 ±1.140; 5.963 ±4.008) tumours (p-
value< 0.05). Tumour volume (ml) was significantly higher on G3 (55 ±15.7)
compared to G1 (1.9± 2.7) and G2 (4.5± 3.6) tumours (p-value < 0.05). In this
small sample size, we did not detect statistically significant parameters
between G2 (n=4) and G3 (n=3) tumours.
Conclusion
Histographic analysis of ADC maps based on the entire tumour
volume can be useful in differentiating histologic grades of PNTs.
B-0158 15:03
Preoperative assessment of the pancreatic fat fraction and fibrosis in
patients who underwent pancreatectomy using breath-hold, T2* corrected
triple-echo Dixon water-fat separation and diffusion weighted imaging
using intravoxel incoherent motion model
J. Yoon
1, J. Lee1, K. Lee1, B. Kiefer2, M. Kang1, J.-Y. Jang1, S.-W. Kim1,
J. Han1, B. Choi1; 1Seoul/KR, 2Erlangen/DE
Purpose: To evaluate diagnostic performance of triple-echo Dixon technique
and intravoxel incoherent motion (IVIM)-diffusion weighted imaging (DWI) for
pancreatic steatosis and fibrosis in the patients who underwent
pancreatectomy, and to determine correlation between pancreatic fat, fibrosis
and incidence of postoperative pancreas fistula (POPF).
Methods
and Materials: This retrospective study was approved by our
institutional review board and informed consent was waived. One hundred sixty
two patients (M:F=92:70, mean age 62 years) underwent MRI at 3.0 T
preoperatively and pancreatectomy. Fat fraction and IVIM-DWI parameters on
MR were compared with fat fraction and fibrosis degree (F0-3) of the
specimen. In addition, fat fractions and IVIM-DWI parameters were compared
in groups with and without POPF. Presence of POPF was determined based
on postoperative imaging, lab findings, and contents of surgical drain tubes.
Results
In 162 patients, fat fraction on MR and that of specimen showed a
strong relationship (r=0.77). Among the IVIM-DWI parameters, only perfusion
fraction was significantly different between F0-1 and F2-3 (30 ±10% vs.
23.3±9.2%, p < 0.005). Fat fraction of the specimen did not show significant
correlation with presence of POPF, either.
Conclusion
Pancreas fat and fibrosis can be quantified on preoperative MR
but the relationship with POPF and imaging parameters was unclear yet.
Author Disclosures:
J. Lee: Advisory Board; Bayer Schering Pharma. B. Kiefer: Employee;
Siemens AG Healthcare sector. B. Choi: Consultant; Samsung.
B-0159 15:12
Pancreatic adenocarcinoma: comparison of six MRI sequences including
diffusion-weighted imaging for tumour conspicuity
F.-X. Arnaud, L. Legrand, E. Sibileau, I. Boulay, M. Zins; Paris/FR
(
[email protected])
Purpose: To assess the best MR sequences for pancreatic adenocarcinoma
conspicuity.
Methods
and Materials: Our local institutional review board approved this
retrospective study and waived the informed consent requirement. 54
consecutive patients with pathologically proven pancreatic adenocarcinoma
underwent MRI (1.5 T, n=27 or 3 T, n=27). Fat-supressed (FS) T1-weighted
gradient-echo (GRE), FS T2-weighted, 3D FS dynamic T1-weighted
gadolinium-enhanced GRE during arterial, portal and delayed phases and
diffusion-weighted imaging (DWI) with b values of 0 and 600 or 800 sec/mm2
were obtained. For each sequence, two gastrointestinal radiologists
independently assessed the subjective vi sual conspicuity using a four-point
rating scale (0 to 3). They designated the sequence with the best visual
conspicuity. The study coordinator perf ormed a quantitative analysis, placing
regions of interest for tumor-to-pancreas contrast (either proximal or distal).
The visual conspicuity scores were compared using Fischer's test, and the
tumor-to-pancreas contrasts were compared using paired Wilcoxon or t-tests.
p-values were considered statistically significant at p < 0.05.
Results
96% of Pancreatic adenocarcinomas appeared hypointense on 3D
FS T1 GRE arterial phase, which was the best sequence for tumor conspicuity
(2.6±0.7), followed by portal phase (2.2 ±1.0) and DWI (2.0± 1.0)(p < 0.01). The
arterial phase was designated as the best sequence in 50% of cases versus
20% for DWI. Greatest tumor-to-pancreas contrast was noticed on the arterial
phase. DWI was not useful for delineating 61% of tumors.
Conclusion
3D FS T1 GRE arterial phase is the best sequence for pancreatic
adenocarcinoma conspicuity. DWI is limited for clear delineation of the tumor.
B-0160 15:21
Is MDCT capable of detecting perineural invasion in pancreatic head
cancer?
E. Kasatkina, V.K. Lyadov, I. Shrayner, S. Bogomazova, E. Mershina,
V.E. Sinitsyn; Moscow/RU (
[email protected])
Purpose: The aim of study was to find whether MDCT is capable to detect
extrapancreatic perineural invasion (EPI) pre-operatively in resectable
adenocarcinoma of pancreatic head. To our knowledge, accuracy for
diagnosing carcinoma invasion into extrapancreatic neural plexus has not been
established.
Methods
and Materials: Preoperative-CT-series of 38 patients with resectable
adenocarcinoma of pancreatic head were evaluated by two independent
observers retrospectively. EPI was iden tified as confluent tissue of similar
attenuation to primary PC extending along neural plexuses pathways. Plexus-
Pancreaticus-Capitalis-II (PLX-II:area along inferioposterior pancreatoduodenal
artery (IPDA) and jejunal trunk) was assessed as this area is more susceptible
for extrapancreatic invasion of pancreatic head cancer. Two patterns of
peripancreatic spread were established: confluent tumour spread (Pattern 1)
and infiltration (Pattern 2) along known pathway or in retropancreatic adipose
tissue.
Results
All patients underwent Whipple-procedure, histologically
adenocarcinoma of pancreatic head was confirmed in all patients. EPI was
found in 26 patients (68.4%), 19 of them showed intrapancreatic perineural
invasion. EPI was more prominent in lager tumours. All 26 patients with
positive PLX-II-invasion were correctl y diagnosed on preoperative CT-scans by
both observers. Interobserver agreement was 92% (Pa=0.922) with Kappa
value=0.63, which represents good agreement between two observers.
Pattern1 was found in 16 patients, Pattern2 in 10 patients. Sensitivity of MDCT
was 99%, specificity 59%, diagnostic accuracy 81%.
Conclusion
MDCT provides sufficient diagnostic information to detect PLX-II-
invasion on preoperative CT-series in patients with adenocarcinoma of
pancreatic head. Preoperative detection of EPI, which is significant cause of
positive surgical margin and tumour recurrence, can influence clinical
management of patient-choice to perform surgical treatment or neoadjuvant
therapy.
S170
B A C D E F G
Thursday
14:00 - 15:30 Room D
Cardiac
SS 203
Myocardial ischaemia and late
enhancement: MRI
Moderators:
G. Bastarrika; Pamplona/ES
A.M. Taylor; London/UK
B-0161 14:00
Combined assessment of stress myocardial perfusion MRI and iterative
super-resolution whole-heart coronary MR angiography in detecting
coronary artery disease
M. Uno, M. Ishida, R. Nakayama, T. Ito, Y. Goto, Y. Ichikawa, M. Nagata,
K. Kitagawa, H. Sakuma; Tsu, Mie/JP (
[email protected])
Purpose: Stress myocardial perfusion MRI is useful for the detection of
coronary artery disease (CAD). Whole-heart coronary MR angiography
(WHCMRA) permits non-invasive visualisation of coronary stenoses. However,
the additive value of WHCMRA to stress perfusion MRI is not well known.
Recently, we have newly developed a super-resolution (SR) technique
optimised for WHCMRA. The purpose of this study was to evaluate the value
of combined assessment of stress perfusion MRI and SR-WHCMRA for
detecting CAD.
Methods
and Materials: 43 consecutive patients (71 ±10 years) with
suspected CAD who underwent both coronary angiography (CAG) and cardiac
MRI including stress perfusion MRI, LGE and WHCMRA within 1 month were
studied. High-resolution WHCMRA was generated by iterative SR technique.
The observers recorded the presence of abnormality representing significant
CAD for stress perfusion MRI, WHCMRA and the combination of both using 4-
point scale, respectively. Stenoses 70% was considered significant on CAG.
Results
129 coronary territories were eligible for the analysis including 20
territories with previous stent implantation. Stress perfusion MRI was
diagnostic in all territories. WHCMRA was diagnostic in all coronary trees
except for stent segments. On vessel-based analysis, diagnostic performance
assessed by area under the ROC curve (AUC) was significantly higher with
combined assessment of SR-WHCMRA and stress perfusion MRI (AUC 0.892;
sensitivity 87.0%; specificity 83.1%) than with stress perfusion MRI only (AUC
0.741; sensitivity 60.9%; specificity 79.5%) (p=0.0005).
Conclusion
Iterative SR-WHCMRA combined with stress perfusion MRI can
provide excellent diagnostic performance for the detection of CAD.
B-0162 14:09
Evaluation of cirrhotic cardiomyopathy in end stage virus C hepatitis by
delayed myocardial enhancement
N.H. Behairy, D. Omran; Cairo/EG (
[email protected])
Purpose: This study aims to evaluate functional and morphological myocardial
changes in hepatitis C virus patients with end stage liver disease listed for liver
transplantation by cardiac magnetic resonance.
Methods
and Materials: Twenty-eight patients with end stage liver disease
secondary to hepatitis C virus listed for liver transplantation were enrolled in
this study. The mean patient's age was 55 ±8 years. The mean model for end-
stage liver disease score was 25.5 ± 6.3. All patients were subjected to routine
laboratory investigations, upper gastrointestinal endoscopy, abdominal
ultrasound, 2D-echocardiography and cardiac magnetic resonance.
Results
All patients showed adequate left ventricle contractility with normal
wall motion and thickness. Patients showed a normal range of ejection fraction
from 55 to 80% with mean 65.5 ±11.8. We found variable degrees of delayed
myocardial enhancement in 21 (84%) of our patients. A significant negative
correlation was found between the percentage of delayed myocardial
enhancement and the ejection fraction, cardiac output, cardiac index and
serum albumin level.
Conclusion
We conclude that severe liver cirrhosis secondary to hepatitis C
virus causes functional and morphological changes within the myocardium
which could be accurately evaluated by cardiac magnetic resonance.
B-0163 14:18
Relevance of small areas of myocardial ischemia in adenosine stress MR
F. Longaretti, M. del Corral, M. Bocciolone, B. Nardi, V. Lisignoli, L. Balzarini,
L. Monti; Rozzano/IT (
[email protected])
Purpose: To compare the clinical relevance of reporting all the areas of
ischemia observed at visual interpretat ion of stress perfusion ("radiologic"
approach: method 1), versus the hypothesis of reporting only mild-to-moderate
areas of ischemia, i.e. > 6% of LV mass ("cardiologic" approach: method 2).
Methods
and Materials: Retrospective re-analysis of a series of stress MR,
with perfusion acquired after 4' of adenosine infusion at 140 mcg/Kg/min, 3
slices every heart beat allowing a 16 myocardial segments evaluation. MR
adenosine stress was reported as positive : In method 1 in the presence of any
area of subendocardial perfusion defect, and in method 2 only if at least 2
subendocardial regions (2 half segments in the 16 segments model).
Results
We analysed a series of 274 stress MR, finding out 75 patients with a
coronary angiography < 3 months after the diagnostic test. Prevalence of
disease among the studied population wa s 73.3%. Method 1: sensitivity 89.1%,
specificity 45%, PPV 81.6% (95%CI :70 to 89); NPV 60% (95% CI 35.7 to
80.2), global accuracy of 77.33%. Method 2: sensitivity78.2%, specificity 75%,
PPV 89.6% (95% CI 77.8 to 95.5), NPV (95% CI 37.3 to 72.4), global accuracy
of 73.3%.
Conclusion
Exclusion of small areas of ischemia doubled the number of false
negative results from 6 to 12. The global accuracy of the exam did not changed
between the 2 reporting methods. Therefore, also small areas of myocardial
ischemia should be reported in a stress MR report.
B-0164 14:27
No reflow as predictor of adverse outcome in patients with acute
myocardial infarction: the role of cardiac magnetic resonance (CMR) and
coronary angiography
G. Benedetti, F. De Cobelli, A. Esposito, A. Damascelli, M. Cava, A. Colombo,
A. Margonato, P.G. Camici, A. Del Maschio; Milan/IT
(
[email protected])
Purpose: No reflow (NR) is a phenomenon due to microvascular obstruction
(MVO), with partially known implication in STEMI patient's outcome. The best
tools to assess the presence of NR are CMR and angiography. The aim of our
study is to assess CMR superiority, compared to angiography, to detect MVO
and predict patient's outcome.
Methods
and Materials: All STEMI patients enrolled in our study underwent
percutaneous coronary intervention (PCI) and CMR within 5 days from the
acute event. We correlated the occurrence of MVO with the incidence of
adverse cardiac events at 1 and at 6 months.
Results
Forty patients (age 61± 10 yrs) were enrolled in the study, 30 of
whom have been followed up for 6 months. Twenty-seven patients had
evidence of MVO (4.9 ± 4.5%) at CMR, while angiography detected only 14.
Three pts experienced events in the 1
st month and there was a significant
correlation between early events and MVO% (p=0.006), but not with LE
extension (p=0.34). Pts with MVO were also hospitalised for a longer period
(p=0.06). Among the 30 pts with 6 months follow-up, we recorded events in 9
patients (1 reinfarction, 7 target lesion revascularisation 8 (TLR), 3 new PCI, 2
CABGs). Patients with MVO at CMR presented a higher incidence of TLR
(p=0.06). The same correlations were not found for angiographic NR.
Conclusion
These data confirm that CMR is more powerful than angiography
in MVO identification. MVO at CMR may help to identify pts with higher
incidence of adverse events and TLR need.
B-0165 14:36
Impact of age-related differences on myocardial salvage (MS), micro-
vascular obstruction (MVO) and left ventricular remodelling (LV-R)
following primary percutaneous coronary intervention (PCI): insights
from cardiac magnetic resonance (CMR)
I. Iacucci, I. Carbone, M. Mancone, D. Gianluca, C. Catalano, M. Francone;
Rome/IT (
[email protected])
Purpose: Elderly population is the most represented in acute coronary
syndromes; however, only few studies investigated impact of age on
myocardial damage in patients presenting with STEMI undergoing primary PCI.
Our aim was to evaluate whether differences in terms of MS, MVO and LV-R
emerged among different tertiles of age in a population of STEMI patients
undergoing CMR.
Methods
and Materials: Ninety STEMI patients, subcategorised into 3 tertiles
(33-50, 51-65, 66-80 years old, group I, II, III, respectively) according to age,
underwent CMR within 5 days after successful PTCA (time-to-reperfusion: 12
hrs within symptom onset) and at 6 months follow-up. Reversible and
irreversible myocardial injury indexes of LV-R were quantified and compared
among groups.
Results
Infarct size (IS), MVO, LV end-systolic and end-diastolic volumes
(ESV; EDV) were larger in group.i. as compared to group III (respectively,
p=0.006, p=0.0001, p=0.019, p=0.004) and were associated with more
significant acute global systolic dysfunction in the same group (mean ejection
fraction: 41.6%; p=0.018). MS was significantly higher in group.i. rather than
group III (p=0.039). Positive LV-R was observed at 6 months follow-up only in
group III patients (LV-ESV > 20%; p < 0.001).
Conclusion
Our preliminary CMR data suggest that age-related differences
exist in acute STEMI patients regarding main indexes of myocardial injury and
are characterised by larger extent of IS and larger micro-vascular damage in
younger patients and adverse remodelling at follow-up in elderly, likely
S171
B A C D E F G
Thursday
reflecting an extreme heterogeneity of early response and late adaptation to
myocardial necrosis
B-0166 14:45
How microvascular obstruction impacts on left ventricle remodelling: a
cardiac magnetic resonance (CMR) study
A. Damascelli, F. De Cobelli, A. Esposito, G. Benedetti, M. Cava, A. Durante,
A. Colombo, P.G. Camici, A. Del Maschio; Milan/IT (
[email protected])
Purpose: The role of CMR in the prognostic stratification of patients with ST-
elevation myocardial infarction (STEMI) is still under investigation. Great focus
has recently been given to the no reflow phenomenon, caused by
microvascular obstruction (MVO). The aim of this study is to evaluate how
CMR parameters progressively change after infarction and how MVO impacts
on left ventricle (LV) remodelling.
Methods
and Materials: In this ongoing prospective study, 43 consecutive
STEMI patients, admitted to our ER and treated with PCI, were enrolled and
underwent a first CMR study (1.5 T magnet) within 5 days from the infarction. A
subgroup underwent a second CMR after 6 months. The main morpho-
functional parameters were assessed on both CMRs. End-diastolic volume
modification between the second and the first CMR ( EDV) was used to
evaluate LV remodelling. The criteria for MVO were a subendocardial lack of
enhancement on first-pass perfusion sequence and/or the presence of a
hypointense region, within the late-enhancement (LE) area.
Results
A group of 14 patients (age 61 ±9 years) underwent both CMR
studies. There was a significant increase in EDV only in the group with MVO as
compared to the group without MVO ( EDV=32 ±27 ml; p=0.005 vs
EDV=4.5±16 ml; p=0.6). MVO, LE and perfusion defects showed a direct
correlation with EDV, with a significant relationship at regression analysis
(MVO%: p=0.001; R2=0.6; LE%: p=0.005, R-squared=0.5; perfusion defect%:
p=0.01; R-squared=0.6). At multivariate analysis only MVO% presented a
significant relation with EDV (p=0.02).
Conclusion
These preliminary data suggest that MVO is involved in LV
remodelling after myocardial infarction.
B-0167 14:54
3D free-breathing cardiovascular 3 T MRI: late gadolinium enhancement
compared to breath-hold 2D imaging
M.B. Bizino, Q. Tao, J. Amersfoort, R.J. van der Geest, H.J. Lamb; Leiden/NL
(
[email protected])
Purpose: Clinical 3D cardiovascular magnetic resonance imaging (CMR) is
desirable, since it allows post-acquisition reformatting in any desired imaging
plane. 3D-CMR is hampered by long breath-hold duration, introducing patient
discomfort and technical limitations. These limitations can be overcome by
application of respiratory navigator techniques, for example to perform late
gadolinium enhanced (LGE) CMR. This 3D approach allows to: (1) perform 3D-
CMR during free-breathing; (2) increase image resolution; (3) average out
heart rate variability by using a phase sensitive inversion recovery sequence
(PSIR); (4) improve myocardial nulling, especially relevant at higher MR field
strength such as 3 T. Therefore, the purpose of the present study was to
develop and clinically test free-breathing 3D-LGE-CMR using a respiratory
navigator approach at 3 T in comparison to standard 2D breath-hold.
Methods
and Materials: Between May 2012 and June 2013, 3D and 2D-PSIR
sequences were acquired after administration of Dotarem (Guerbet).
Retrospectively, 26 patients with LGE were selected for analysis (21 men;
mean age ± standard deviation: 62.2 ±7.8). Myocardial scar tissue (ml), SNR,
CNR and edge sharpness (ES) of scar tissue were quantified. Parameters
were compared with a paired t-test.
Results
Myocardial scar tissue volume (3D: 27.11 ±17.94; 2D:
29.50±15.43 ml; p = 0.49), SNR (3D: 100.88± 31.97; 2D: 89.92± 18.57; p=0.06)
and CNR (3D: 3.96 ±1.84; 2D: 3.55 ±0.68; p=0.25) were not significantly
different between 3D and 2D sequences. ES was significantly higher for 3D
CMR (3D: 0.051±0.0072; 2D: 0.048±0.0085; p=0.019).
Conclusion
Free-breathing 3D-LGE-CMR enables reliable myocardial scar
tissue assessment with improved image resolution as compared to standard
2D breath-hold imaging.
B-0168 15:03
Cardiac magnetic resonance imaging findings and the risk of
cardiovascular events in patients with recent myocardial infarction or
suspected or known coronary artery disease: a systematic review of
prognostic studies
H. El Aidi
1, A. Adams1, K. Moons1, H. den Ruijter1, P. Doevendans1, E. Nagel2,
S. Schalla3, M. Bots1, T. Leiner1; 1Utrecht/NL, 2London/UK, 3Maastricht/NL
(
[email protected])
Purpose: The purpose of this study was to investigate the association
between CMR findings and future cardiovascular events by systematically
reviewing the current literature.
Methods
and Materials: Cohort studies published before 2013 identified by
systematic MEDLINE and EMBASE searches and citation tracking were
evaluated. Studies evaluating associations between CMR findings (left
ventricular ejection fraction [LVEF], wall motion abnormalities [WMA],
myocardial perfusion, microvascul ar obstruction [MVO], late gadolinium
enhancement [LGE], edema, and intramyocardial haemorrhage [IMH]), and
hard events (all-cause mortality, cardiac death, cardiac transplantation,
myocardial infarction) or major adverse cardiovascular events (MACE) were
included.
Results
Of the 3,040 (MEDLINE) and 656 (EMBASE) articles retrieved, 56
matched our selection criteria (n=25,497 patients). For patients with a recent
myocardial infarction, no relation was found between CMR findings and hard
events, but late MVO (adjusted hazard ratio (HR)-range: 1.03-10.4, 668
patients) and IMH (adjusted HR-range: 1.17-2.80, N=749) were independently
associated with MACE. In patients with suspected/known CAD, inducible WMA
(adjusted HR-range: 1.87-2.99, N=2,863), and inducible perfusion defects
(adjusted HR-range: 3.02- 7.77, N=4,012) were independently associated with
hard events. Inducible perfusion defects were also associated with MACE
(adjusted HR-range: 1.76-3.21, N=2,392). For other CMR findings, either no
association was found or few studies were available.
Conclusion
Among patients with a recent myocardial infarction, late MVO and
IMH are independently associated with MACE. In patients with
suspected/known CAD presence of inducible WMA are associated with hard
events and inducible perfusion defects are associated with hard events and
MACE.
B-0169 15:12
Size of late gadolinium enhancement in patients with hypertrophic
cardiomyopathy in correlation with serum MMP9 as an indicator of
myocardial fibrosis
M. Avanesov, M. Patten, J. Münch, P. Bannas, D. Sähring, E. Tahir, G. Adam,
G. Lund; Hamburg/DE (
[email protected])
Purpose: We compared size of late gadolinium enhancement (LGE) obtained
by cardiac magnetic resonance (CMR) imaging in patients with hypertrophic
cardiomyopathy (HCM) with serum MMP9, which is a marker of myocardial
fibrosis.
Methods
and Materials: CMR was performed in 50 patients with HCM (mean
age: 54.9 ±14.1 years, 27 women) using a 1.5 Tesla scanner (Achieva,
Philips). Size of fibrosis was quantified in percent of total myocardium on
inversion-recovery images after injection of 0.2 ml/kg gadolinium using the
HeAT software and compared with levels of serum MMP9. A serum level of
> 46 ng/ml was regarded as increased.
Results
Nine out of 50 patients with HCM (18 %) showed no fibrosis on LGE-
CMR. In the remaining 41 patients, mean size of fibrosis was 13.3 ±10.3% on
LGE-CMR. In all patients, the mean MMP9 level was 54.4 ±35.2 ng/ml. Size of
fibrosis on LGE-CMR strongly correlated with MMP9 levels (R2=0.557,
Pearson's r= 0.75, p < 0.01). In the 9 patients with no LGE, MMP9 was with
29.6 ± 14.2 ng/ml significantly lower compared to the 41 patients with LGE and
levels of 59.8 ± 36.2 ng/ml (p =0.01).
Conclusion
Size of fibrosis on LGE-CMR strongly correlated with the serum
fibrosis marker MMP9 in patients with HCM. However, 2% of patients revealed
no LGE despite increased MMP9 levels. These patients may have a diffuse
myocardial fibrosis which is not detectable by standard LGE-CMR.
B-0170 15:21
Do left ventricular volumes correlate with late enhancement in
hypertrophic cardiomyopathy?
G. Muscogiuri1, M. Di Girolamo1, C.N. De Cecco2, S. Fierro1, D. Magrì1,
V. David1; 1Rome/IT, 2Latina/IT (
[email protected])
Purpose: To correlate left ventricular volumes and late enhancement (LE)
mass in patients with hypertrophic cardomyopathy.
Methods
and Materials: We retrospectively evaluated 85 patients with HCM
diagnosis. All patients were studied with a 1.5 T MR. The study protocol
included cine True-Fisp sequences (TR:3.09 ms,TE:1.3 ms, FA:80,thick:8 mm)
followed by inversion recovery Turbo-Flash sequences for LE evaluation
(TR:8 ms,TE:4 ms,TI:250-340 ms,thick:8 mm) acquired 10-15 minutes after iv
administration of 0.2 mmol/kg of Gadolinium. Left end-diastolic volume (EDV),
end-systolic volume (ESV), stroke volume (SV), ejection fraction (FE) and LE
mass was measured on short axis by manual planimetry using a dedicated
software. LE was considered as an area with SI > 6SD from normal tissue.
Patients were divided in two different subgroup with LE (Group 1) and without
LE (Group 2). For statistical analysis we used Spearman's correlation.
Results
The following results were observed respectively in Group 1 and 2:
LE mass 12±16 g, EDV 121±37 ml, ESV 39 ±21 ml, SV 87±23 ml, EF 72±9% in
Group 1 and EDV 115 ±29 ml, ESV 31 ±18 ml, SV 84 ±20 ml, EF 76 ±9% in
Group 2. Patient with LE presented higher EDV, ESV, SV and lower EF in
comparison to patients negative for LE. Significant correlation was not
observed between LE mass and EDV (p=0.6) and SV (0.25) while statistical
S172
B A C D E F G
Thursday
significant correlation was observed between LE mass, ESV (0.01) and EF
(0.0001).
Conclusion
This study show that an increase of LE mass is correlated with a
decrease of left ventricle EF and increase of ESV.
14:00 - 15:30 Board Room B
Head and Neck
SS 208
Pathologies of the orbit and temporal bone
Moderators:
T. Rodt; Hannover/DE
B.F. Schuknecht; Zurich/CH
B-0171 14:00
Exploration of orbital and orbital soft-tissue volume changes with gender
and body parameters by using magnetic resonance imaging
M.F. Erkoç
1, A. Okur2, B. Öztoprak1, C. Gümü1; 1Sivas/TR, 2Yozgat/TR
(
[email protected])
Purpose: Understanding the volumetric values of eyeball and changes with
age and gender will allow us to solve serious clinical implications. This study
aimed to examine the total orbital volume (TOV) and total orbital fat expansion
(TOFE) in normal people with three different age groups and to find the
correlation of these measurements due to age, gender and body parameters
(height and weight) by MRI.
Methods
and Materials: MRI data were acquired retrospectively. Total of
1453 subjects were included and were divided into three age groups: 481
subjects in 20-30 years age (240 males and 241 females), 521 subjects in 40-
60 years age (253 males and 268 females) and 451 subjects in 60-70 years
age (212 males and 239 females). The TOV and TOFE were measured using
T1-weighted MR images for each subject, and clinical information's (age,
gender, height and weight) were also obtained.
Results
The measurements showed that TOV decreased by age and the
volume was larger in men than in women. While both weight and height
showed positive correlations with TOV in male and female subjects in their 20s
and 40s, only weight showed a positive correlation with TOV in female subjects
in their 60s. On the other hand, TOFE increased by age in all groups and the
increment was larger in women than men.
Conclusion
These results provide basic information about the effect of age,
gender, and body parameters on TOV and TOFE. The variations in TOV are
associated with orbital soft tissues changes rather than with TOFE.
B-0172 14:09
Orbital colour Doppler ultrasound assessment in patients affected by
Leber's hereditary optic neuropathy and dominant optic atrophy
C. Colantoni, M. Venturini, E. Borrelli, M. Cascavilla, P. Barboni,
A. Del Maschio; Milan/IT (
[email protected])
Purpose: To investigate the vascular dysfunction in patients with Leber's
hereditary optic neuropathy (LHON), and with dominant optic atrophy (DOA),
that are genetic diseases which cause visual loss due to microvascular
disorders.
Methods
and Materials: Six asymptomatic LHON patients (cLHON), 2 acute
patients (aLHON), 8 chronic patients (chLHON), 6 patients with DOA, and 10
control subjects underwent a complete ophthalmologic examination including
enhanced depth imaging--optical coherence tomography, and OCDUS
performed with a ATL-Philips IU-22, and a 5-12 MHz linear probe. Patients
were examined with closed eyelids in supine position. Peak systolic velocity
(PSV), end-diastolic velocity (EDV), and resistive index (RI) of ophthalmic
artery (OA), central retinal artery (CRA), central retinal vein (CRV), short
posterior ciliary arteries (SPCA).
Results
In cLHON: SPCA EDV (cm/s)=5.0 ±1.4, SPCA RI=0.64 ±0.16, OA
RI=0.59±0.06, in controls, respectively: 2.4 ±0.6 (P=0.001), 0.76 ±0.03 (P=0.02)
and 0.75± 0.04 (P=0.001); SPCA in aLHON: EDV=7.1 ±2.1, PSV
(cm/s)=21.3±4.5, RI= 0.67± 0.03, in controls, respectively: 2.4 ±0.6 (P < 0.001),
10.3±2.8 (P=0.001) and 0.76 ±0.03 (P=0.005); CRA PSV: in chLHON= 8.6 ±2.3
(P=0.04), in aLHON=15.4 ±0.9, in controls=12.9 ±3.0; SPCA RI in
aLHON=0.67±0.03, in chLHON=0.80 ±0.0 (P=0.002); SPCA PSV: in DOA=
7.2±1.6, in controls=10.3±2.8 (P=0.01). A significant PSV increase of both CRA
and SPCA in aLHON, compared to cLHON and to controls, and a subsequent
reduction in the chronic phase and in DOA was found.
Conclusion
OCDUS can be a useful diagnostic tool to investigate the
vascular involvement, probably related to the microangiopathy, of LHON and
DOA at different stages of the disease, providing quantitative and reproducible
data: in the future, OCDUS could monitor the response to treatment.
B-0173 14:18
Feasibility of 3 T IDEAL MR of the orbits for imaging of Graves'
ophtalmopathy: correlation between quantitative evaluation of
extraocular muscle size and proptosis value
D. Guerrieri, G. Panzironi, M. Guida, C. Di Paola, F. De Cristofaro, L. Garau;
Rome/IT (
[email protected])
Purpose: To investigate the feasibility of 3 T MR iterative decomposition of
water and fat imaging (IDEAL) sequences for imaging of Graves'
ophtalmopathy, assessing extraocular muscle size and proptosis value.
Methods
and Materials: 3 T IDEAL MRI was performed on 56 patients with
symptoms of Graves' orbitopathy. Coronal and axial T2-weighted IDEAL fast
spin-echo sequences were acquired in all patients; axial scans were obtained
in the neuro-ocular plane. Since IDEAL sequences permit fast and accurate
water-fat separation with a single acquisition, we measured maximum cross-
sectional area of extraocular muscles (EOM) on coronal T2 sequences after a
visual comparison between water-only and fat-only images with a free-hand
ROI. Proptosis value was quantified on axial images with Hertel Index, i.e. the
distance from the interzygomatic line and the apex of the globe; correlation
was measured with the Pearson correlation coefficient.
Results
We found a moderate correlation ( p
< 0.05) between Hertel index and
areas of EOM (right: r=45-59, left: r=40-52); this association was stronger for
inferior, medial and superior rectus mu scles and even stronger combining all
areas for each orbit (right: r=60; left: r=56).
Conclusion
Orbital 3 T IDEAL MR imaging is a fast and useful procedure in
the evaluation of patients with Graves' ophtal mopathy. In a single acquisition,
this technique provides excellent water and fat separation, thus permitting an
accurate and reproducible quantification of muscle hypertrophy and proptosis
value; in facts artifacts deriving from incomplete or wrong fat suppression with
conventional techniques are markedly reduced.
B-0174 14:27
Dynamic contrast-enhanced magnetic resonance imaging of ocular
melanoma
J. Xuyuan
1, P. Asbach2, G. Willerding2, M. Dulce2, K. Xu3, M. Taupitz2,
B. Hamm2, K. Erb-Eigner2; 1Shenyang/CN, Berlin/DE, 2Berlin/DE,
3Shenyang/CN (
[email protected])
Purpose: Dynamic contrast-enhanced magnetic resonance imaging (DCE
MRI) is used for assessment of microvasculature in several tumours. We
aimed to assess the contrast signal enhancement characteristics of ocular
melanoma.
Methods
and Materials: Forty patients with ocular melanoma were
prospectively investigated with ocular MRI including DCE sequences during a
13-month period. A region-of-interest analysis of the images was performed to
calculate the time to achieve the maximum enhancement (Tmax), the washout-
ratio (WR), the enhancement ratio (ER) and the maximum rise slope (SL)
within 106 seconds of the ocular melanoma in all patients. Ocular melanomas
were grouped with respect to their enhancement curve pattern.
Results
In 39 patients (98%), the ocular melanomas showed an early strong
signal enhancement after contrast injection, resulting in a mean Tmax of 49
sec. The mean WR of the ocular melanoma was 21.3%. In 30 patients (75%),
the peak enhancement was followed by a washout of more than 10%. In 9
patients (23%), the washout was less than 10 % resulting in a plateau pattern.
Conclusion
Ocular melanoma demonstrates signal enhancement
characteristics of hypervascular neoplasms. This study provides baseline curve
pattern data that may be useful for assessing changes in vascularity, e.g.
during therapy response.
B-0175 14:36
Contrast-enhanced ultrasound in the quantitative assessment of uveal
melanoma response to gamma knife radiosurgery: do changes in tumour
vascularisation precede thickness variation at ultrasound?
C. Colantoni, M. Venturini, G. Modorati, A. Colucci, M. Di Nicola, G. Agostini,
F. De Cobelli, F. Bandello, A. Del Maschio; Milan/IT (
[email protected])
Purpose: To prospectively analyse CEUS in the quantitative assessment of
UM response to GKR, investigating if changes in tumour vascularisation
precede thickness variation, the conventional US response parameter, which
on average occurs at 12 months.
Methods
and Materials: Ten patients (7 males, 3 females; mean age ±SD,
66.2±12.62 years) with UM were treated with GKR. US and CEUS were
performed (SonoVue, Bracco ) with iU-22 ATL (Philips) and a 5-9 MHz linear
probe at baseline, 3, 6, and 12 months after treatment. UM transverse
diameter, thickness, and different quantitative parameters, such as area-under-
the-curve in the wash-in-phase, wash-in-perfusion-index, peak-enhancement,
and wash-in-rate, were calculated using a dedicated software (Sonotumor,
Bracco).
Results
At US the mean tumour thickness (mm) after GKR was: at baseline=
8.3, 3 months after= 7.4 (P=ns), 6 months after= 6.6 (P =0.031), 12 months
S173
B A C D E F G
Thursday
after= 5.8 (P=0.024). At CEUS, the parameters at baseline, 6 months and 12
months after treatment resulted respectively: peak-enhancement (a.u). = 2*10 7,
8*105 (P=.018), 4*10 1 (P=.028); wash-in rate (a.u). = 4*10 6, 8*10 4 (P=.028),
7*100 (P=.028); wash-in perfusion index (cm 3/sec) = 6*10 7, 2*10 6 (P=.028),
1*102 (P=.043); area under the curve (a.u). = 9*10 8, 3*10 7 (P=ns), 1*10 3
(P=.028). At 6 months after treatment, tumour thickness decreased in 6/10
patients, while UM enhancement in 10/10.
Conclusion
CEUS showed an early UM enhancement reduction at 6 months
after GKR. A larger population is needed to investigate if CEUS could be either
an additional tool to conventional US or the first choice technique to monitor
UM response to GKR.
B-0176 14:45
Imaging of perilymph fistulae of the round and oval windows in the
absence of a fracture
Z. Aloraini, F. Veillon, S. Riehm, J.-F. Matern, B. Rock, A. Charpiot, C. Debry,
P. Hemar; Strasbourg/FR (
[email protected])
Purpose: To evaluate reliability of CT and MRI in diagnosing perilymph fistulae
(PLF) of the round window (RW) and oval window (OW), in the absence of a
fracture.
Methods
and Materials: Amongst all patients (n = 101) clinically suspected of
FPL, 61 have a CT, 40 MRI (including 31 CT + MRI) studied by three
radiologists (two seniors, one junior) with reference to a normal population in
CT (n = 30).
Results
The sensitivity and specificity for the FR in MRI are better than CT:
respectively 94.4%(IRM), 90.3% (TDM) et 95.5% (IRM)/93.3 % (TDM). CT and
MRI produce the same results for the sensitivity analysis of the FO: 92.3 %
(IRM)/85.7 % (TDM). However, the specificity for the FO in CT (97.9%) is
higher than that of MRI (96.3%). By combining the two techniques, the
sensitivity was 90%, positive predictive value (PPV) was 100%. False positive
cases were explained by difficulty differentiating between inflammatory and
perilymphatic fluid, false negatives by intermittent flow fistulae.
Conclusion
CT and MRI can play a key role in diagnosing PLF.
B-0177 14:54
Functional MSCT of temporal bone as a new standard in differential
diagnostics of a conductive hearing loss
I.V. Bodrova, L.A. Kulakova, N.V. Gagarina, E.V. Fominykh, S. Ternovoy;
Moscow/RU (
[email protected])
Purpose: to assess possibilities of fMSCT in evaluation of ossicular mobility in
patients with conductive hearing loss in comparison with healthy individuals.
Methods
and Materials: 75 persons (107ears) have been examined by
audiologic tests, fMSCT: 13 healthy adult volunteers and 62 patients with
conductive hearing loss. CT was performed on 320-detector CT with dynamic
scan mode with simultaneous exposure of sound signal. 46 patients (56ears)
were underwent otosurgery.
Results
We evaluate 6 main criteria of normal ossicular mobility in healthy
volunteers. In patients' group we revealed the follow pathology: 17 patients
with otosclerosis had restriction or absence of motility of stapes footplate; 10
patients with adhesive otitis media had decrease degree of motion of ossicles
chain; 4 patients with tympanosclerosis had absence of motility of malleus; 3
patients had absence of motion due to rupture of incudostapedial joint and one
patient with hypoplasia of ossicular chain had loss of motion. From the group of
27 patients with previous stapedoplasty we observed 11 cases of prosthesis
dysfunction due to: compression by otosclerotic focus (5 cases), the loop of
prosthesis slid off the long limb of at movement (2 cases), the loop was opened
and adjoined an tympanic membrane (2 cases), fracture of the long limb of
incus (2 cases). All CT-findings were compare with otosurgery results and
correlation were 98%.
Conclusion
FMSCT is a new noninvasive diagnostic method for evaluation of
ossicular mobility, that helps to choose an optimal surgical approach in patient
with conductive hearing loss.
B-0178 15:03
Size of the membranous inner ear in different ages and sexes: volumetric
assessment using three dimensional reconstructed high resolution MRI
of the inner ear
N.N.N. Naguib, A. Morgan, N.-E.A.N. Mohammed, T. Lehnert, T. Gruber-Rouh,
I. Burck, M. Harth, T.J. Vogl; Frankfurt a. Main/DE (
[email protected])
Purpose: Volumetric assessment of the membranous inner ear in different
ages and to check the differences in volume among both sexes and between
both sides in the same patient using three dimensional (3D) reconstruction of
the high-resolution MR-Imaging (HR-MRI).
Methods
and Materials: 350 patients with a mean age of 48.5year were
included. HR-MRI was performed using a T2-weighted SPACE sequence with
0.6 mm slice thickness. 3D-reconstructions were performed using Advantage
Workstation. Volumetric assessment was manually performed for each side in
all patients. The difference between different ages was tested using Pearson-
linear-regression test. The difference between both sides and sexes was
tested using student T-test and Wilcoxon-Mann-Whitney test respectively.
Results
The mean volume of the left inner ear in all patients was 0.526 mm3
(SD:0.097, Range:0.300-0.870). On the right side it was 0.520 mm3 (SD:0.010,
Range:0.270-0.910). The mean volume of the inner ear was 0.520 mm3
(SD:0.099, Range:0.300-0.870) and 0.527 mm3 (SD:0.098, Range:0.270-
0.910) in females and males respectively. No statistically significant difference
was noted between both sides in the same patient (p=0.37) or between both
sexes (p=0.48). A statistically significant reduction in the volume of the inner
ear with increased age was noted (p < 0.0001). The volume of the inner ear is
significantly reduced by 0.0017 mm3 every year of age.
Conclusion
The volume of the inner ear is significantly reduced with
increased age at a rate of 0.0017 mm3/year of age. There is no significant
difference in volume between both sexes or both sides in the same patient.
B-0179 15:12
Orbital Colour-Doppler Ultrasound (OCDUS) and Spectral-Domain Optical
Coherence Tomography (SD-OCT) assessment in brittle type 1 diabetic
(T1D) patients after timely percutaneous intraportal pancreatic islet
transplantation (PIPIT)
S. Margari, M. Venturini, L. Pierro, P. Maffi, R. Lattanzio, F. De Cobelli,
A. Secchi, A. Del Maschio; Milan/IT (
[email protected])
Purpose: PIPIT is a less invasive alternative to pancreas transplantation.
Diabetic retinopathy (DR) represents the major cause of visual loss in T1D
patients. OCDUS and SD-OCT are fast/non-invasive examinations: the first
quantifies the peak systolic velocity of central retinal artery (PSV-CRA), the
second allows high-resolution cross-secti onal retinal images. Our aim was to
assess the clinical relationship between retinal blood flow and morpho-
structural retinal changes after PIPIT.
Methods
and Materials: Eight T1D patients, 5 affected and 3 unaffected by
DR, were submitted to OCDUS and SD-OCT before and after PIPIT. DR,
based on fundus biomicroscopy, PSV-CRA with OCDUS, macular thickness
and presence of micropseudocysts (MPCs) with SD-OCT, C-peptide (Cp), as a
biomarker of islet function, were assessed at baseline and at 1, 2, 3, 4, 5 years
from PIPIT. Statistical analysis was performed by Mann-Whitney U Test.
Results
PSV-CRA, in patients with and without DR, respectively, was as
follows: before PIPIT 7.86 ± 1.38 cm/s vs 8.06 ± 1.50; after PIPIT
8.39 ± 1.01 cm/s vs 12.61 ± 2.73 (p < 0.05). SD-OCT showed a retinal
thickness 250 microns, but the presence of MPCs in 2 patients with DR. Cp,
in patients with and without DR, respectively, was as follows: before PIPIT
0.76 ± 0.48 ng/ml vs 0.62 ± 0.48; after PIPIT 0.72 ± 0.51 ng/ml vs 1.32 ± 1.21.
Conclusion
A timely PIPIT in brittle T1D patients, still unaffected by DR,
determines a restoration of islet function and a beneficial effect on the retinal
microcirculation, improving PSV-CRA and Cp values.
B-0180 15:21
Volumetric assessment of the cochlea in patients with long-standing
unilateral sensorineural hearing loss: comparison with the normal side
N.N.N. Naguib, A. Morgan, T. Lehnert, T. Gruber-Rouh, I. Burck, M. Harth,
R. Hammerstingl, T.J. Vogl; Frankfurt a. Main/DE (
[email protected])
Purpose: To compare the cochlear volume of the diseased side in patients
with long-standing unilateral hearing loss with the cochlear volume of the
normal side using three di mensional (3D) reconstr uction of the high-resolution
MR-Imaging (HR-MRI) sequences.
Methods
and Materials: 81 patients with a mean age of 45.2 years were
included. All patients had long-standing unilateral hearing loss. HR-MRI was
performed using a T2-weighted SPACE sequence with 0.6-mm slice thickness.
3D reconstructions were performed using Advantage Workstation. The
difference between the cochlear volume of the normal and the diseased side
was tested for statistical significance using the two-sample t test.
Results
Unilateral hearing loss affected the right side in 35 patients and the
left side in 46 patients. The mean cochlear volume in all patients and both
sides was 0.1721 mm
3 (Standard deviation (SD): 0.0303, range: 0.1000 -
0.2800 mm3). The mean volume of the cochlea in the diseased side was
0.1717 mm3 (SD: 0.0287, range: 0.1000 - 0.2700 mm 3). The mean volume of
the cochlea in the normal side was 0.1725 mm 3 (SD: 0.0320, Range: 0.1100 -
0.2800 mm3). There was no statistically significant difference between the
volume of the cochlea on the diseased side and the normal side (p = 0.87).
Conclusion
There is no statistically signi ficant difference in the cochlear
volume between the diseased side and the normal side in patients with
unilateral long-standing sensorineural hearing loss.
S174
B A C D E F G
Thursday
14:00 - 15:30 Room E1
Musculoskeletal
SS 210
Knee, ankle and foot
Moderators:
C. Faletti; Turin/IT
J. Renoux; Paris/FR
B-0181 14:00
Treatment of non-traumatic posteromedial knee pain due to
semimembranosus tendinopathy: a study assessing the efficacy of
ultrasound guided injections in 92 patients
W. Bashir
1, D.P. Baghla2, A. Musah3, J. Bell2, D.A. Connell4; 1Birmingham/UK,
2London/UK, 3Nottingham/UK, 4Melbourne/AU
Purpose: Assess effectiveness of ultrasound (US) guided steroid injections in
the management of posteromedial knee pain due to semimembranosus
tendinopathy (SMT).
Methods
and Materials: 92 (42 male, 50 female) patients (mean age 42
years) referred for MRI over a 5 year period with medial knee pain had a
diagnosis of semimembranosus tendinopathy made. The patients were
subsequently referred for US confirmation after which an US-guided injection
of 40 mg triamcinolone and 2 ml 0.5% Bupivacaine was administered. Patients
were reviewed at 1 week, 4 weeks, 3 and 6 mont hs. VAS pain sco res were
recorded pre-procedure and post procedure.
Results
MRI showed tendon thickening with intratendinous high SI and fluid in
the adjacent bursa on fat saturated images. Sonography confirmed thickening
of the tendon with varying degrees of hypoechogenicity ± inflammatory
changes in the adjacent bursa. Significant VAS pain score reduction was
observed after injection when compared to that at presentation. US also
showed improvement in tendon fibrillar morphology.
Conclusion
Semimembranosus tendinopathy (SMT) should be actively
sought as a potential aetiology when revi ewing an MRI of the knee, especially
in patients presenting with medial knee pain as it is a frequent and easily
treatable cause of knee pain. SMT has been described in the past as being
secondary to a compensatory biomechanical mechanism in patients with
significant intra-articular pathology but our study shows that it can also be
found in young individuals suffering from non-traumatic medial knee pain.
Ultrasound can confidently confirm the diagnosis, guide injections and monitor
changes of SMT.
B-0182 14:09
Total knee arthroplasty: early post-surgical malrotation
M. Ereno Ealo, E. Pastor Ausin, B. Sancho Garaizabal, E. Montejo,
F.M. Labayru Echevarrria; Galdacano/ES (
[email protected])
Purpose: Pain after TKA Surgery: CT showing early malrotation and benefits
of correction.
Methods
and Materials: 35 knee arthroplasty revisions were performed in
patients with a persistent pain after an uncomplicated TKA. Cases of
component loosening or infection were excluded. The component rotation
measurement was based on the technique described by Berger et al. Femoral
component rotation: angle between the trans epicondylar axis and the posterior
condylar axis. (0-3º in women and 3-5º in men). Tibial component rotation: 3
slices at different levels were analysed including the tip of the tubercle. (neutral
n 18º and internally rotated when larger). Knee Society Prosthesis Score, Knee
Society Function Score, Oxford Scores, Range of motion, Laxity, Patellar
maltracking and Pain were evaluated pre and post-surgery in all patients.
Results
Mean preoperative femoral rotation was -2.6º. Mean preoperative
tibial rotation was -4.3º. Mean preoperative femoral and tibial rotation was -
6.8º. Knee Society Prosthesis Score: 42.3 (10-62) in pre revisions and 78.8
(65-95) in post surgery revisions. Knee Society Function Score: 37.7 (5-60) in
pre-revisions and 48.9 (10-85) in post-surgery revisions. Range of motion: 85.9
(50-125) in pre-revisions and 105.9 ( 85-135) in post-surgery revisions. In all
cases p value < 0.001
Conclusion
These was a significant improvement experienced by patients
after TKA revision for malrotation. The CT is recommended in the evaluation of
patients with early painful TKA and no evidence of infection.
B-0183 14:18
The clinical impact of leukoscan imaging in managing peri-prosthetic
joint infection
T.J. Gordon, R. Govinda Rajoo, V. Prakash; Chertsey/UK
(
[email protected])
Purpose: Three phase bone scintigraphy followed by Leukoscan imaging is a
popular investigative cascade for the diagnosis of infected total hip and knee
replacements. This study analyses how the use of Leukoscans in a UK
secondary hospital setting impacts on the management of suspected peri-
prosthetic joint infection.
Methods
and Materials: Case based analyses were performed covering a 24
month period (2010-2012), inclusive of clinical follow-up. Patients had triple
phase bone scintigraphy followed by a Leukoscan. The corresponding clinical
action, inclusive of further investigations and management, was examined.
Further investigations included a 24-hour repeat of the Leukoscan and joint
aspiration for microbiological confirmation of infection. Management was
categorised into the following broad categories: no action, conservative
management, and surgery.
Results
55 patient cases were analysed. Triple phase bone scintigraphy was
positive in 89% and negative in 11%. Leukoscans yielded positive results for
infection in 55% and negative in 45%, with 22% of patients receiving a 24-hour
repeat Leukoscan. Microbiological confirmation was sought in 47% in which all
cultures of joint aspirate were negative. The result of the Leukoscan prompted
a change in management in 66%, in which 33% received conservative
management and the remaining 33% underwent revision surgery. No change
in management was observed in 34%.
Conclusion
Triple phase bone scintigraphy is best used as a screening test.
When negative it confidently rules out disease. Accuracy of isolated
Leukoscans remains controversial. This study suggests that there is no robust
correlation between the results of a Leukoscan and the resultant clinical action.
B-0184 14:27
MR findings in asymptomatic volunteers at the calcaneal attachment of
the plantar fascia
C. Ehrmann, M. Maier, B. Mengiardi, C.W.A. Pfirrmann, R. Sutter; Zurich/CH
Purpose: To assess MR findings at the calcaneal attachment of the plantar
fascia in asymptomatic volunteers.
Methods
and Materials: The study was approved by the institutional review
board and informed consent was obtained. MR examinations of 77
asymptomatic volunteers (40 women, 37 men; mean age 48.0 years, range 23-
83 years) were obtained. Two msk fellowship trained radiologists analysed
signal characteristics and thickness of the m edial, central and lateral fascicle of
the plantar fascia were assessed. Moreover, the presence of soft tissue
oedema, bone marrow oedema and bony spur formation at the attachment of
the plantar fascia was noticed.
Results
Mean thickness of the plantar fascia was 4.0 mm (central fascicle),
0.6 mm (medial fascicle), and 2.3 mm (lateral fascicle). Increased signal
intensity in the plantar fascia was seen in 16 volunteers (20.8%) in the T1w
sequence, in 6 volunteers (7.8%) in the T2w sequence and in 5 volunteers
(6.5%) in the STIR sequence. Soft tissue oedema above the plantar fascia was
seen in 5 volunteers (6.5%) and below the plantar fascia in 16 volunteers
(20.8%). A calcaneal spur was noted in 15 volunteers (19.5%). Calcaneal bone
marrow oedema was present in 4 volunteers (5.2%).
Conclusion
Soft-tissue oedema below the plantar fascia as well as calcaneal
spurs are common findings in asymptomatic volunteers and should be used
with caution for diagnosing plantar fasciit is. Increased signal on fluid sensitive
sequences within the plantar fascia is less frequent in asymptomatic
volunteers.
B-0185 14:36
High-volume image-guided injection with or without steroid for achilles
tendinopathy: a prospective study
H. Abdulhussein
1, D. Morrissey1, O. Chan2; 1Harrow/UK, 2London/UK
(
[email protected])
Purpose: High-volume image-guided injections (HVIGI's) have been shown to
improve outcomes in Achilles tendinopathy patients. The injection traditionally
contains Hydrocortisone Acetate, however this prospective cohort study was
the first to assess the injection with no steroid, just saline. Aiming to ascertain
any difference in the outcomes of pain, function, symptoms and return to
sporting activity between patients receiving a HVIGI with steroid, and without.
Methods
and Materials: Patients were recruited consecutively from the
London Independent Hospital. 21 patients (24 tendons) were injected with a
HVIGI of either 10 Mils of Marcaine 0.5% mixed with 25 mg of hydrocortisone
plus 40 Mils of Normal Saline (with steroid) or 50 Mils of Saline plus local
anaesthetic (without steroid). All patients were placed on an eccentric loading
exercise (ELE) programme. The Victorian Institute of Sports Assessment -
Achilles tendon (VISA-A) questionnaire was the primary outcome measure,
secondary outcome measure was a VAS scale.
Results
VISA-A scores improved significantly in both groups, from a pre-
injection mean of 39.3 to 60.7 in steroid cohort, and from 42.0 to 73.5 in the
non-steroid group at final follow-up. Improvements in VAS scores were seen in
both groups. No statistically significant difference in VISA-A scores between
the two groups at any point (p=0.703).
Conclusion
HVIGI without steroid shows similar trends in pain reduction and
functional improvement in comparison to currently used HVIGI with steroid.
S175
B A C D E F G
Thursday
Further research with imaging outcomes and longer follow-ups is necessary,
however these findings suggest a non-steroid injection is a viable option.
B-0187 14:45
A new protocol of MRI evaluation of two different techniques in anterior
cruciate ligament recontruction
M. Busacca, D. Capannelli, C. Tetta, R. Buda, E. Ferranti Calderoni,
U. Albisinni; Bologna/IT (
[email protected])
Purpose: The aim of this study is to evaluate integration and maturation of
autologous graft in anterior cruciate ligament (ACL) reconstruction with
magnetic resonance imaging (MRI) and to evaluate correlation between MRI
findings and clinical outcome at 6-month follow-up.
Methods
and Materials: 40 patients (range 17-49 yrs, M/F 35/5) treated with
ACL reconstruction were evaluated with MRI 6 months after surgery. 20 were
treated with "all-inside" technique (half femoral tunnel HFT) and 20 with "over
the top" technique (complete femoral tunnel CFT). A new sequence protocol
was optimisated for the analysis of the graft structure including DP with and
without fat saturation on sagittal and coronal sequences and FSE-T2-3D ±FS.
Figueroa scoring scale was used to evaluate integration (presence of synovial
fluid at tunnel-graft interface), ligamentati on (graft signal pattern: hypointense,
isointense or hyperintense) and characterisation of the graft (poor or
adeguate). IKDC score, KOOS and Tegner scale were collected.
Results
Synovial fluid at tunnel-graft interface was present in 6 cases with
HFT and in 7 cases with CFT. The graft signal pattern was iso-hypointense in
13 cases with HFT and 13 cases with CFT, whereas it was hyperintense in 7
cases with HFT and 7 cases with CFT. The characterisation of the graft was
poor in 3 patients with HFT and no cases were observed in CFT group.
Conclusion
MRI findings at 6-month follow-up demonstrate no statistically
significant differences between two groups in terms of integration assessment
and graft maturation (ligamentation), whereas "all-inside" technique has a
better clinical outcome.
B-0188 14:54
Qualitative and quantitative assessment of vastus medialis muscle
atrophy at MR imaging in asymptomatic patients after anterior cruciate
ligament reconstruction
M. Marcon
1, B. Ciritsis2, C. Laux2, T. Nguyen-Kim2, M.A. Fischer2,
G. Andreisek2, E. Ulbrich2; 1Udine/IT, 2Zurich/CH (
[email protected])
Purpose: To quantitatively and qualitatively assess the vastus medialis
muscle, an important clinical indicator for postoperative knee function, at MR
imaging in asymptomatic patients with anterior cruciate ligament (ACL)
reconstruction. The non-operated leg served as internal control.
Methods
and Materials: Prospective IRB approved study with written
informed patient consent. Thirty-five asymptomatic patients (men, 23; women,
12) with ACL-reconstruction underwent MR imaging of both legs using an axial
T1-weighted and a 3D spoiled dual gradient-echo (LAVA FLEX) sequences.
Muscle volume and fat-signal-fraction (FSF) of the vastus medialis muscles
were determined. Additionally, two readers evaluated fatty muscle atrophy
using the Goutallier classification. Studen t t test was used to test significant
muscle volume, muscle FSF, and fatty atrophy differences between the
operated and non-operated legs. A p-value <.125 indicated statistical
significance.
Results
The vastus medialis muscle volume was significantly smaller in the
operated (mean ±SD, 430.6 ±119.6 cm3; range, 197.3-641.7 cm3) compared to
the non-operated leg (mean ±SD, 479.5 ±124.8 cm3; range, 261.4-658.9 cm3)
(p.>125). The mean±SD percentage side-to-side difference in muscle volume
was 10.2 ±8.5% (range, -7.1- 30.1%) and in FSF 5.8 ±22.6% (range, -38.9-
40.1%). Qualitative assessment of muscle atrophy revealed no significant
differences between the operated and non-operated leg (p=.30 for reader 1;
p=.20 for reader 2).
Conclusion
In asymptomatic patients with ACL-reconstructions, a significant
atrophy of the vastus medialis muscle exists, but without fatty degeneration.
B-0189 15:03
Magnetic resonance imaging findings after lateral ankle trauma in injured
and contralateral ankles
N. van Putte-Katier
1, J. van Ochten2, S.M.A. Bierma-Zeinstra2,
M. van Middelkoop2, E.H.G. Oei2; 1Dordrecht/NL, 2Rotterdam/NL
(
[email protected])
Purpose: To determine the prevalence of structural MRI abnormalities after
lateral ankle trauma in injured and contralateral asymptomatic ankles to identify
lesion types that may be preexistent
Methods
and Materials: 195 patients (mean age 37.5 years; 43% male)
included in an observational case-control study on persistent symptoms after
lateral ankle trauma completed a questionnaire and MRI (1.5 T) of both ankles
6-12 months after visiting their general practitioner for an inversion ankle
trauma. Prevalence of ankle lesions was compared between injured and
contralateral ankles. Multivariable anal ysis was performed to investigate the
association between lesions frequently seen in both ankles (i.e. anterior
talofibular (ATFL) and calcaneofibular ligament (CFL) lesions) and recent
trauma, previous trauma, age, gender, BMI and osteoarthritis.
Results
Bone marrow edema, joint effusion, soft tissue edema and peri-
articular calcifications were found in both ankles, but significantly more
frequently in the injured ankle. Peroneal tendon lesions were rarely seen in
both ankles. Anterior and posterior tibi ofibular ligament lesions, deltoid
ligament lesions and signs of talona vicular osteoarthritis were almost
exclusively found in the injured ankle. ATFL and CFL lesions were frequently
found in both ankles, in 55.9% and 37.4% of the injured ankles, respectively
and in 17.9% and 5.6% of asymptomatic contralateral ankles, respectively.
ATFL lesions were related to recent trauma, gender and age, CFL lesions were
related to recent trauma and gender.
Conclusion
The prevalence of structural MRI abnormalities in injured and
asymptomatic ankles is high, suggesting that some lesions (especially ATFL
and CFL lesions) are pre-existent.
B-0190 15:12
Ligamentous injury patterns and risk of associated tissue damage in
athletes with ankle sprain
F.W. Roemer1, N. Jomaah1, J. Niu2, E. Almusa1, B. Roger1, P. D'Hooghe1,
J. Tol1, C. Geertsema1, A. Guermazi1; 1Doha/QA, 2Boston, MA/US
(
[email protected])
Purpose: To describe retrospectively the structural injury pattern in athletes
that were referred to MRI for evaluation of acute ankle sprain and to assess the
risk of associated traumatic tissue damage beyond lateral and syndesmotic
ligament involvement.
Methods
and Materials: 261 ankle MRIs of athletes with acute ankle sprain
were evaluated with regard to lateral and syndesmotic ligament injury. As
concomitant injuries the deltoid and spri ng ligaments, sinus tarsi, peroneal,
flexor and extensor retinacula and tendons, traumatic bone changes and joint
effusion were assessed. Six exclusive injury patterns were defined based on
lateral and syndesmotic ligament involvement. Risk for associated injuries was
estimated using logistic regression.
Results
Athletes were on average 22.5 years old and mean interval from
injury to MRI was 5.7 days. 103 (39.5%) had a complete anterior talofibular
ligament injury and no syndesmotic injury and 53 (20.3%) had syndesmotic
involvement. Acute lateral osteochondral lesions of the talar dome were seen
in 20 (7.7%) ankles and chronic lateral osteochondral lesions in 3 (1.1%). Risk
for associated deltoid ligament injury was increased for ankles with lateral
ligament injury (aOR 4.04, 95% confidence interval (CI) 1.99-8.22). Risk for
talar bone contusions was increased for ankles with any syndesmotic injury
(aOR 3.43, 95% CI 1.72-6.85).
Conclusion
About 20% of athletes referred for MRI after suffering an acute
ankle sprain have evidence of syndesmotic injury, whilst about 40% have
evidence of lateral ligament injury without syndesmotic involvement.
Concomitant talar osseous and deltoid ligament injuries are common.
14:00 - 15:30 Room E2
GI Tract
SS 201b
Advances in small bowel imaging
Moderators:
P. Soyer; Paris/FR
V. Vandecaveye; Leuven/BE
B-0191 14:00
Dynamic contrast-enhanced magnetic-resonance imaging (DCE-MRI) of
small bowel and MR flow analysis of mesenteric vessels in patients with
Paroxistic Nocturnal Haemoglobinuria (PNH) with and without abdominal
pain
G. Pezzetti, F. De Cobelli, S. Margari, A. Esposito, G. Ironi, A. Del Maschio;
Milan/IT (
[email protected])
Purpose: We aimed to assess if DCE-MRI of small bowel wall and flow
analysis of mesenteric vessels may identify early ischaemic signs in PNH
patients, with (AP) and without (NAP) abdominal pain, which exact
pathogenesis has never been determined by in vivo imaging studies.
Methods
and Materials: Six AP and six NAP PNH-fasted patients were
scanned using a 1.5 T MRI with a phased-array coil, after ingestion of PEG
solution and during Gadobutrol i.v. injection. Mean flow (MF) and stroke
volume (SV) of superior mesenteric vein (SMV) and artery (SMA) with ECG-
gated phase-contrast flow-mapping sequences were assessed. Areas under
the curve at 60 (AUC
60) and 90 seconds (AUC 90) and k-trans in six locations of
S176
B A C D E F G
Thursday
small bowel wall with perfusion sequences were calculated. Statistical analysis
was performed with Mann-Whitney test.
Results
All the parameters above were lower in AP than in NAP: AUC 60:
84.81 1/s ± 4.99 vs. 131.73 ± 18.47; p = 0.002; AUC 90: 102.33 ± 5.76 vs.
152.58 ± 23.11; p = 0.002; k trans: 0.0240 ml / ml*min ± 0.0019 vs.
0.0369 ± 0.0009 (p=0.093 duodenum, 0.009 jejunum, 0.004 ileum). SMV: MF
4.67 ml/s ± 0.85 vs. 8.32 ± 2.14; p = 0.002; SV 3.85 ml ± 0.76 vs. 6.55 ± 1.57;
p = 0.015. SMA: MF 6.95 ± 2.61 vs. 11.2 ± 2.32; SV 6.52 ± 2.19 vs.
8.78 ± 1.63; p = 0.065.
Conclusion
Small intestine blood-supply impairment could be an early and
reliable MRI marker of mesenteric ischaemia in PNH patients with abdominal
pain.
B-0192 14:09
Training readers to improve their accuracy in grading luminal Crohn's
disease activity on MRI
J.A.W. Tielbeek, S. Bipat, T.N. Boellaard, C.Y. Nio, J. Stoker; Amsterdam/NL
(
[email protected])
Purpose: To prospectively evaluate if training with direct feedback improves
grading accuracy of inexperienced readers in determining luminal Crohn's
disease activity on MR imaging.
Methods
and Materials: Thirty-one readers (14 radiologists, 17 residents)
without prior experience participated in a structured MR training program with
individual hands-on training. All re aders assessed 100 MR examinations of
patients with Crohn's disease, randomly assigned to four sets of 25 cases and
received direct feedback. An expert panel determined disease activity per case
for determining the reference standard. To determine the effect of training with
direct feedback, the proportions of grading accuracy, understaging and
overstaging per set were compared using logistic regression analyses. Mean
reading times and confidence scores (scale 0-10) were calculated and
compared by t-test.
Results
Grading accuracy of all trainees was 51% (95%CI:41-60%), 60%
(95%CI:51-69%), 63% (95%CI:52-72%) and 75% (95%CI:66-81%) in the four
consecutive sets, respectively. Grading accuracy increased after 75 cases with
direct feedback (P < 0.001). Understaging decreased, from 23% (95%CI:15-
33%) to 7% (95%CI:3-14%) (P < 0.001). Overstaging did not change
significantly.
The accuracy for grading none, mild, moderate and severe CD in the last set
was 75% (95%CI:62-84%), 70% (95%CI:55-82%), 63% (95%CI:54-71%) and
87% (95%CI:62-96%), respectively. Mean reading time decreased from 6:37 to
4:35 minutes (P < 0.001). Mean confidence increased from 6.90 to 7.65
(P < 0.001).
Conclusion
Grading accuracy, reading time and confidence of inexperienced
readers in evaluating Crohn's disease activi ty on MR improved during training
with feedback. Inexperienced readers need training with at least 75 cases
before achieving the accuracy as reported in literature.
B-0193 14:18
MR enterography in the study of patients with Crohn's disease: which
findings of MRE are more likely to change the gastroentologist's
management of the patient?
S. Rajabi, L.A. Stein, C. Reinhold, T. Bessissow, I. Dupuis, A. Prucha,
A. Benmassaoud; Montreal, QC/CA (
[email protected])
Purpose: To determine which signs of Crohn's Disease (CD) on magnetic
resonance enterography (MRE), are most likely to change patient-
management.
Methods
and Materials: Data on 63 CD patients were collected at McGill
University Hospitals. 22 signs of CD were shown on MRE for these patients.
Management post-MRE were stratified as: 1) no change, 2) change in
medication dose, 3) change in medication, and 4) surgery and/or
hospitalisation. Data concerning disease location, behaviour (Montreal CD
classification), previous surgery and recent CRP prior to MRE were retrieved.
Logistic regression (univariate/multivariate analyses) was used to determine
which MRE and clinical signs were associated with management change.
Results
Of the 22 MRE signs, the most common were circumferential-wall-
thickening (60.3%), and wall-enhancement post-Gadolinium (52.9%). 55.6% of
patients had management changed (35 patients, with some overlap in groups
2.3,4) versus 44.4% with no change (group1). Logistic regression performed
on clinical and MRE data showed: high CRP values, mesenteric engorgement,
and bowel-wall-thickening had significant relationship with change of
management vs. no change (group1). Circumferential-wall-thickening, and
enhancement post-gadolinium had a significant relationship with change in
medication (group3). Disease behaviour, CRP, tethering of bowel loops,
spiculated mesenteric disease, and ileocolic disease were shown to have a
significant relationship with the deci sion to perform surgery/hospitalise a
patient (group4). Ordinate outcomes analysis, where the 4 different categories
of management change were assumed to be different levels of change,
showed patients with decreased motility to have higher odds of more severe
change of management.
Conclusion
The information obtained here can guide radiologists as to which
signs of CD are more important to look for on MRE from a patient-management
perspective.
B-0194 14:27
Staging of Crohn's disease activity using CT, MRI, US and scintigraphy: a
meta-analysis
C.A.J. Puylaert, J.A.W. Tielbeek, S. Bipat, J. Stoker; Amsterdam/NL
(
[email protected])
Purpose: To assess the role of computed tomography (CT), magnetic
resonance imaging (MRI), ultrasonography (US) and scintigraphy (SG) in
staging Crohn's disease (CD) activity.
Methods
and Materials: MEDLINE, EM BASE and Co chrane databases were
searched for studies evaluating CT, MRI, US and SG in staging CD activity as
compared to (ileo)-colonoscopy or histology as the reference standard. Two
independent reviewers assessed the data. Three by three tables (none, mild,
frank disease) were constructed for all studies and overall diagnostic
accuracies were calculated/summarised by fixed or random-effects models.
Results
Our search yielded 8347 articles, from which 20 articles were
determined eligible for inclusion. A total of 577 patients were included. On per-
patient basis: 2, 13, 1 and 1 datasets were available for respectively CT, MRI,
US and SG. Data were not pooled for US and SG and showed accuracy values
of 44% (95%CI:26-62%) and 40% (95%CI:12-74%) in the available datasets.
CT and MRI data were pooled and showed similar overall grading accuracy
estimates of 86% (95%CI:75-93%) and 84%(95%CI:68-93%), respectively
(P=0.78). On per-segment basis: 2, 2, 2 and 3 datasets were available for
respectively CT, MRI, US and SG. The overall grading accuracy estimates
were respectively 74% (95%CI:68-80%), 78% (95%CI:72-82%), 66%
(95%CI:52-78%) and 80% (95%CI:75-85%). US had the lowest accuracy. CT,
MRI and SG had comparable accuracy (P > 0.05).
Conclusion
US has the lowest accuracy for grading CD. SG showed mixed
Results
for per-patient and per-segment data. CT and MRI showed comparable
high accuracy values both on per-patient and per-segment analysis.
B-0195 14:36
Does HRCT allow the prediction of oesophageal involvement in systemic
sclerosis?
T. Nguyen-Kim, B. Maurer, P. Nyffenegger, O. Distler, T. Frauenfelder;
Zurich/CH (
[email protected])
Purpose: To correlate oesophageal diameters measured on CT with
manometry-findings in patients with systemic sclerosis (SSC).
Methods
and Materials: 148 patients with SSc underwent HRCT for SSc-
assessment. From all patients information about dysphagia, dyspepsia, globus-
sensation, odynophagia, heartburn, regurgi tation was obtained. All patients
fulfilling the ACR-Criteria, and underwent manometry were included (n=53,
41female, median-age 59, range 28-80). Based on manometry, two groups
were defined (group1:pathologic manometry (n=39), group2: normal
manometry (n=14)). Esophageal diameter,area and perimeter were measured
by two independent readers on CT-images at following levels: largest diameter
above and below the aortic arch, respectively on level of carina,
pulmonalvenous confluens and 1 cm above right diaphragm. ROC-curves
regression analyses were applied to correlate CT-measurements with
manometry and clinical symptoms.
Results
Mean maximal diameter/area/perimeter was for group1
13.1 mm/106.8 mm2/36.2 mm (level of
carina),11.6 mm/75.7 mm2/31.9 mm (level of pulmonalvenous confluens),
9.8 mm/77.9 mm2/27.8 mm (level 1 cm above right diaphragm) and for group2
7.5 mm/37.6 mm2/24.1 mm (level of carina), 11.1 mm/91.2 mm2/33.7 mm
(level of pulmonalvenous confluens), 7.9 mm/66.7 mm2/26.9 mm (level 1 cm
above right diaphragm). The largest mean diameter/area/perimeter above and
below the aortic arch were 11.7 mm/101.2 mm2/33.7 mm and
17.0 mm/149.4 mm2/47.2 mm for group1 and 7.7 mm/34.6 mm2/21.5 mm,
respectively 10.8 mm/59.6 mm2/28.7 mm for group2. The maximal diameters
did not differ significantly between both groups. Interreader-variability was
good (k=0.69). On level of carina, a cut-off perimeter of 31.2 mm allowed to
differentiate between group1 and group2 with a sensitivity of 71% and a
specificity of 87% (area under the curve 0.77). No correlations were found
between CT-measurements and clinical findings. Significant correlations were
found between CT-measurements and manometry on level of carina (p 0.02)
and below the aortic arch (p0.01).
Conclusion
HRCT allows to predict pathologic manometry-findings in patients
with SSc using a cut-off perimeter of 31.2 mm on level of carina with a positive
predictive-value of 98%.
S177
B A C D E F G
Thursday
B-0196 14:45
Small bowel motility measurements in MRI using 2D coronal slices: does
the intrasegmental location matter? (a pilot study)
S. Bickelhaupt, J.M. Froehlich, M.A. Patak; Zurich/CH (
[email protected])
Purpose: Small bowel motility analyses using dynamic MRI acquisition in
coronal plane are of increasing clinical interest. The aim of this study was to
evaluate if quantitative results of small bowel motility analyses in coronal plane
are influenced by the positioning of the 2D cross-section measurement point
within the small bowel`s lumen.
Methods
and Materials: 44 small-bowel motility measurements in 6
participants (male; mean 37.8years) were included in this IRB approved,
prospective study. MRI (3.0-T,Ingenia-Philips) was performed after
standardised preparation. 3D-motility sequences (Dixon-dynFFE;TR 2.508;TE
11.254; slice thickness 3 mm; temporal resolution 1 sec) covering the
ileocaecal region were acquired in breathhold over 42-56 sec. Motility was
analysed measuring 2D cross-section diameters of the small-bowel lumen in
three different locations (ventral, central and dorsal) of the same segment
using a motility-assessment software. Curve characteristics (diameter,
amplitude, extent of luminal occlusion during contractions) were compared for
all three locations using ANOVA and paired student`s t test.
Results
Mean luminal diameter was 11.82 mm (SD ±5.02) in the ventral,
13.49 mm (SD ±4.44) in the central and 10.57 mm (SD ±3.92) in the dorsal
compartment of the bowel lumen without significant difference between the
compartments (p> 0.05). Contraction amplitudes (ventral: 10.47 mm, SD ±2.61;
central: 10.89 mm, SD ±2.93; dorsal: 10.55 mm,SD ±3.21) did not differ
(p=0.878) as well as the extent of luminal occlusion during the contractions
(p=0.11) (ventral:0.97,SD±0.29; central:0.88,SD±0.28; dorsal:1.04,SD±0.25).
Conclusion
Quantitative motility parameters are not substantially influenced
by the choice of cross-sections on the coronal planes as long as the segment
is visible throughout the measurement.
B-0197 14:54
Is mesenteric panniculitis truely a paraneoplastic phenomenon? A
matched pair analysis
Ö. Gögebakan
1, T. Albrecht1, M.A. Osterhoff2, A.J. Reimann1; 1Berlin/DE,
2Nuthetal/DE (
[email protected])
Purpose: Mesenteric panniculitis (MP) is an underdiagnosed inflammatory
condition of mesenteric adipose tissue. Prior studies suggested an association
of MP with malignancy. To reassess this hypothesis, we performed the first-
matched case-control study comparing prevalence of malignancy and other
disease in patients with and without MP.
Methods
and Materials: With a keyword search, we identified CT
examinations of MP patients between 2010 and 2012. Each MP patient was
matched with two control patients for age, gender, abdominal diameter and CT
protocol. Manifestation and extent of mesenteric panniculitis was classified
independently by two investigators according to established criteria.
Concomitant disease, laboratory parameters and follow-up CTs were recorded
and analysed for all patients.
Results
77 of 13485 CT patients were diagnosed with MP (prevalence
0.58%). 50.6 % of MP patients suffered from malignancy vs. 60.2% in the
control group (p = 0.157). Over up to 4 years of follow-up in 35 of these 77 MP
patients, no association between development of MP and the course of tumour
diseases could be identified. There was also no significant difference in the
rate of frequent concomitant diseases, such as hypertension, diabetes or
previous surgery between the two groups.
Conclusion
In this first case-control study, we could show that, contrary to
previous reports, mesenteric panniculitis is neither paraneoplastic nor it is
associated with other diseases.
B-0198 15:03
Assessment of acute intestinal graft versus host disease by abdominal
magnetic resonance imaging at 3 Tesla
J. Budjan, H.J. Michaely, U.I. Attenberger, S. Haneder, D. Heidenreich,
S. Kreil, W.-K. Hofmann, S.O. Schönberg, S.A. Klein;
Mannheim/DE (
[email protected])
Purpose: After allogeneic stem cell transplantation (SCT) a reliable
differentiation between acute graft versus host disease (aGvHD) and its
differential diagnoses is esse ntial for an early and successful treatment. Aim of
this study is to assess intestinal aGvHD by magnetic resonance imaging (MRI).
Methods
and Materials: As part of our routine preparation prior to allogeneic
SCT 78 consecutive patients underwent abdominal MRI examination after
informed consent on a 3 T MR-scanner (Magnetom Skyra, Siemens) including
axial and coronal T2w sequences with and without fat-saturation and a three-
dimensional dynamic T1w, contrast-enhanced sequence with a spatial
resolution of 0.9x0.9x0.9 mm3. After SCT patients with suspected aGvHD
received a second MRI as well as endoscopic examination with multiple
biopsies for histologic investigation.
Results
Nine patients (aGvHD-group) suffered from histologically proven
intestinal aGvHD. In ten control-group patients, no intestinal aGvHD was
diagnosed. In all aGvHD patients characteristic MRI findings with long-segment
bowel wall thickening - always involving the terminal ileum - with profound
submucosal edema were detected. The bowel wall was significantly thickened
in patients with intestinal aGvHD in comparison with control group patients
(mean wall thickness of the small intestine: aGvHD-group 8 mm, control-group
3 mm, p < 0.001; large intestine: aGvHD-group 9 mm, control-group 3 mm,
p < 0.001). Bowel perfusion spared the submucosa while demonstrating strong
and patchy mucosal hyperemia. Free abdominal fluid was seen in the majority
of aGvHD patients.
Conclusion
In intestinal aGvHD, a characteristic MR-appearance can be
detected. This MRI pattern might facilitate an early and non-invasive diagnosis
of intestinal aGvHD.
B-0199 15:12
Role of oral contrast medium in x-ray defecography
F. Testa, D. Fraire, C. Nyffenegger, M. Baigi, M. Lo Bello; Bra/IT
(
[email protected])
Purpose: Oral contrast medium in x-ray defecography is not required in all
procedures, but is mandatory to detect enterocele. To consider administering
an oral contrast to all patients who undergo the procedure.
Methods
and Materials: We reviewed our consecutive series of 139
procedures in last 4 years on patients suffering from disorders in the
evacuation. For each procedure we have considered the presence or absence
of enterocele and, if present, its extent. All our procedures were made with oral
contrast medium administred to the patient one hour before the exam.
Results
139 defecographies in 131 female patients and 8 male patients
(mean age 61.6 years, median age 62 years) showed an amount of 52
enteroceles (37.4%), classed in 32 mild enteroceles (61.5 %, not interfering
with the evacuation) and 20 severe enteroceles (38.5 %, interfering with the
evacuation). No signifiant difference was recognised in efficacy between
barium and iodinated contrast media.
Conclusion
The high rate of enterocele suggests the opportunity of use of an
oral contrast in all patients who undergo defecography. The choice between
barium and iodinated contrast media can be accomplished on the basis of the
patient's clinical history.
B-0200 15:21
Prevalence of significant findings on magnetic resonance enterography
(MRE) beyond Crohn's
P.M. Yeap, M. Budak, J. Weir-McCall, M. Szewczyk-Bieda, I. Zealley;
Dundee/UK (
[email protected])
Purpose: Magnetic resonance enterography (MRE) is increasingly used for
evaluation of the small bowel in patients with Crohn's disease. Occasionally
other pathologies unrelated to Crohn's may be sought, or be identified when
Crohn's is suspected. We aimed to determine the frequency of significant
incidental findings detected by MRE in patients with suspected or known
Crohn's disease, which may have important impact on clinical management.
Methods
and Materials: Single centre study of 807 MRE performed between
January 2004 and March 2013. Clinical details of study population and their
respective MRE reports were obtained from local Computerised Radiology
Information System and were retrospectively reviewed. Significant incidental
findings were defined as enteric or extra-enteric findings unrelated to Crohn's
that may account for presenting symptoms or requiring further investigation.
Results
Of 807 MRE, 98% were performed for suspected or known Crohn's.
Only 2% were performed for more esoteric diagnosis particularly in young or
pregnant patients. 38 (4%) of MRE had signif icant incidental findings, of which
58% (n=22) were bowel pathologies and 42% (n=16) were extra-enteric. Extra-
enteric pathologies included gynaecological (n=7), mesenteric (n=3), urinary
tract (n=2), biliary tree (n=1), neural crest (n=1), retroperitoneum (n=1), and
vascular (n=1). Bowel findings were mainly of adhesion (23%), obstruction
(18%), and intussusception (9%).
Conclusion
Although only a small proportion of patients have significant
incidental findings at MRE, it is desi rable that radiologists are aware of the
MRE appearances of diseases affecting the small bowel other than Crohn's,
and of extra-enteric diseases that may hav e similar clinical presentation to
Crohn's.
S178
BA C D E F G
Thursday
14:00 - 15:30 Room F1
Oncologic Imaging
SS 216
New imaging biomarkers and decision-
making in oncology
Moderators:
G.P. Schmidt; Munich/DE
C.A. Cuénod; Paris/FR
B-0201 14:00
Breast MRI as a potential biomarker to predict occurrence of metastasis:
is there any additional value compared to classical prognostic factors?
M. Dietzel1, R. Zoubi2, C. Jerowski3, W.A. Kaiser3, P.A.T. Baltzer4;
1Erlangen/DE, Jena/DE, 2Bielefeld/DE, Jena/DE, 3Jena/DE, 4Vienna/AT,
Jena/AT
Purpose: There is increasing evidence that breast-MRI could be used as a
non-invasive prognostic-biomarker. However, most previous investigations
addressed surrogates of outcome as endpoint, i.e. tumour-grading, steroid-
receptors, etc., instead of direct endpoints such as distance-metastasis.
Furthermore, the additional value of breast-MRI compared to classical
prognostic-factors remains poorly investigated. Accordingly, we aimed to
investigate the additional value of breast-MRI compared to conventional
prognostic-factors to predict occurrence of distance metastasis.
Methods
and Materials: Patients with newly diagnosed invasive breast cancer
receiving pre-therapeutic breast-MRI at our institution were eligible
(standardised protocol according to EUSOBI-recommendations; 1.5 Tesla).
Classical prognostic-factors included nodal-status, T-stage, typing, tumour-
grading, in situ components, steroid-receptors and herceptin-receptor-status.
All patients were followed-up according to national-guidelines and occurrence
of distant-metastasis was documented. Breast-MRI was analysed semi-
automatically by a commercial CAD-system (computer-assisted-diagnosis). It
allows to semi-quantitatively assess characteristic enhancement-parameters
(n=15) of the breast-cancer. Logistic-regression was used to identify accuracy
of classical prognostic-factors alone and in combination with breast-MRI to
predict occurrence of distant-me tastases (ROC: receiver-operating-
characteristics; AUC: area-under-the-ROC-curve; inter-AUC-comparison).
Results
During a mean follow-up of 55 months, 38 out of 251 women (15.8%)
were diagnosed with distant-metastasis. If used separately, breast-MRI
(AUC=78.8%) and classical prognostic-factors (AUC=80.0%) showed
moderate accuracy to predict distant-metastases without significant difference
(P=0.8). Yet, the combined use of breast-MRI and classical prognostic-factors
significantly increased overall accuracy to AUC=87.1% (P < 0.001).
Conclusion
Breast MRI has a major potential as a non-invasive biomarker.
According to our data it adds significant prognostic value to classical
prognostic factors to predict distance metastasis in breast cancer.
B-0202 14:09
Comparison between MRI and CT in prediction of peritoneal
carcinomatosis index in patients undergoing peritoneal surgery in
relation to the radiologist's experience
M. Torkzad
1, N. Casta2, A. Bergman2, H. Ahlström2, H. Mahteme2;
1Sollentuna/SE, 2Uppsala/SE (
[email protected])
Purpose: To compare CT and MRI for assessment of total PCI and tumour
burden per site and assessments made by the radiologists.
Methods
and Materials: In 19 prospective cases of peritoneal carcinomatosis,
MRI of the abdomen (with T1-weighted TSE, T2-weighted TSE, 3D T1-
weighted fat saturated images before and contrast enhancement with Gd, and
diffusion-weighted images with b 1000) and contrast-enhanced CT (portal
venous phase) was used within two days and maximum one week before
surgery. An inexperienced radiologist and an experienced (MRI and CT)
abdominal radiologist evaluated the image s separately on different occasions
and blinded to clinical data. The agreement between the radiologists'
assessment and surgical findings in total and per site were measured and
compared.
Results
Total PCI: experienced radiologist assessed total tumour burden
correctly on both CT and MRI (kappa = 1.0). The inexperienced radiologist
assessed CT better (kappa = 0.73) than MRI (kappa = 0.58). Different sites:
Experienced radiologist showed higher agreement per location with kappa =
0.77 for MRI and 0.80 for CT. The same figures were 0.39 and 0.60 for the
inexperienced radiologist. The best results of experienced radiologist for
assessment of the small intestine and its mesentery were seen with CT while
for pelvis, upper abdomen and the flanks the best agreement was seen on
MRI.
Conclusion
Degree of experience influences assessment of PCI more than
choice of modality. The difference between CT and MRI results is partially
related to experience and tumour site for the inexperienced radiologists.
B-0203 14:18
Remaining malignant lymph nodes in good responders after
chemoradiotherapy for rectal cancer: where are they located?
L.A. Heijnen, D.M. Lambregts, M.H. Martens, M.J. Lahaye, M. Maas,
G.L. Beets, R.G.H. Beets-Tan; Maastricht/NL (
[email protected])
Purpose: Minimally invasive treatments may be an option in rectal cancer
patients showing a good or complete tumour response after
chemoradiotherapy (ypT0-2). However, regardless the primary tumour
response, remaining metastatic lymph nodes withhold a risk for recurrence.
Knowledge on the presence and location of these ypN+ nodes may help guide
treatment intensification (boost radiotherapy) to further sterilize the nodes. Aim
of this study was to investigate location patterns of remaining ypN+ nodes in
good/complete tumour responders.
Methods
and Materials: 211 locally advanced rectal cancer patients
underwent chemoradiotherapy, which resulted in downstaging to ypT0-2 in 134
patients, who constituted the final study group. For the patients with a ypT0-
2N+ status, a lesion-by-lesion MR-histologic analysis was performed on the
location of the individual ypN+ nodes.
Results
8/134 ypT0-2 patients (6%) had a yp2N+ status. 47% of the ypN+
nodes were located at the same height as the tumour, the other 53% were
located proximal to the tumour at a distance of 1.2-6.5 cm above the tumour
level (40% within 5 cm above the tumour, in the
presacral area). In the axial plane, 71% of the nodes were located near (within
< 1 cm from) the tumour/rectal lumen.
Conclusion
The incidence of remaining malignant nodes in case of good
tumour response after CRT is very low. Remaining nodal metastases are solely
located at the same level or proximal to the tumour. The majority of N+ nodes
are located near the tumour/lumen.
B-0204 14:27
Preoperative evaluation of rectal cancer with MR: how to increase
diagnostic accuracy of N staging?
M. Gatti, R. Faletti, M. Benedini, S. Stola, A. Rapellino, A. Dominguez,
A. Grasso, P. Fonio, G. Gandini; Turin/IT (
[email protected])
Purpose: To evaluate the accuracy of magnetic resonance (MR) on loco-
regional staging of rectal cancer focus on nodes, and compare the results to
histologic findings, considered as standard reference.
Methods
and Materials: Between July 2011 and March 2013, 61 patients, 31
(52.5%) males, age 66.75 ±13.77, with rectal cancer, were staged
preoperatively with MR and had surgical resections performed. Two
radiologists blinded to the pathology results performed the MR evaluation
independently. Nodal size, border contour, signal intensity and localisation
were considered on 265 nodes for N malignant score (p1, p2, p3). The ADC
values of N were measured in regions of interest. Comparison between
imaging and histopathologic findings was ca rried out with different approaches:
Chi-square test, analysis of variance (ANOVA), Kruscal-Wallis' test, Cohen's
kappa coefficient and ROC curve.
Results
MR accuracy for T-stage was Kw= 0.87 ±0.06, interoperator variability
was not statistical significant (Kw=0.62 ±0.08). Nodes were divided into p1=198,
p2=17, p3=50. Accuracy on node defined suspicious (p3) was kw=0.62 ±0.08.
ADC values for nodes were p1=1.227 ±0.298 mm2/s, p2=1.120 ±0.306 mm2/s
and p3=0.818 ±0.168 mm2/s. We defined a threshold ADC value of 1 mm2/s
and the correlation with malignant node was strong (AUC=0.88). The
percentage of malignant nodes [p3/(p1+p2)] is higher in the external iliac lymph
nodes than pre-sacral and meso-rectal ones (55.6% vs. 17.5 and 17.6%).
Conclusion
Magnetic resonance imaging is an accurate imaging method in
staging of rectal cancer. Prediction of nodal involvement could be improved
using ADC value, which is a reliable and reproducible evaluation.
B-0205 14:36
Pre-operative MRI in early stage cervical cancer may predict the need of
adjuvant therapies: a single-center experience
S.A. Angileri, S. Rizzo, S. Maccagnoni, G. Calareso, F. Landoni, S. Raimondi,
E. Pasquali, R. Lazzari, M. Bellomi; Milan/IT (
[email protected])
Purpose: To determine whether MRI and DWI may predict which patients are
candidate to adjuvant therapies in early-stage cervical cancer.
Methods
and Materials: Data about adjuvant therapies, minimum uninvolved
stroma, maximum stromal involvement, positive lymph nodes were collected in
217 patients operated for early-stage cervical cancer (FIGO IA1-IIB). ADC
maps were avaible in 51/217 patients. Measures from pathological reports
were used as reference standard. P-values < 0.05 were considered significant.
Results
113/217 (54%) patients underwent adjuvant therapies (9
chemotherapy; 21 radiotherapy; 83 radio-chemotherapy). Sensitivity,
S179
BA C D E F G
Thursday
specificity, positive/negative predictive values and accuracy of MR imaging in
evaluating minimum thickness of uninvolved cervical stroma were respectively
88%, 75%, 70%, 90% and 80% while for pelvic positive lymphnodes were
64%, 85%, 65%, 84% and 78%. MR and pathological results were concordant
about maximum depth of stromal invasion in 207/217 patients (95%). Depth of
stromal invasion was strongly related to positive nodal status (p < 0.001). DWI
showed no correlation with histological type, grade or presence of lymph node
metastasis.
Conclusion
Pre-surgical MR evaluation can predict the need of adjuvant
therapies because of the high accuracy in measuring the minimum thickness of
uninvolved stroma and the maximum depth of stromal invasion. MR accuracy
in detection of positive lymph nodes was 78%. Depth of stromal invasion was
strongly related to the presence positive lymph nodes.
B-0206 14:45
Five-year results of prostate cancer permanent brachytherapy: the
importance of postimplant CT-based quality control
O. Apolikhin, A. Sivkov, B. Oschepkov, D. Roshin, A. Koryakin; Moscow/RU
(
[email protected])
Purpose: Brachytherapy is a high-tech method, which arose from Radiology
and Minimally Invasive Urology as the result of the accumulation of significant
experience in radiation therapy and the latest knowledge of radiation biology
and dosimetry. However, the real seed distribution doesn`t always match the
preplan. The main purpose of the study was to asses the long-term results
depending on the postimplant dosimetry.
Methods
and Materials: Single-centre results of brachytherapy with 125I
sources in 117 prostate cancer patients of low and intermediate-risk group
(according to the D `Amico criteria) with an average follow-up of 5 years,
operated in FSBI Institute of Urology from 2000 to 2013. In the postoperative
period (on the 30
th day) patients underwent CT-based PDA (postimplantation
dosimetric analysis), which restated the basic dosimetric parameters - one of
the most important - D90 (dose that is received by 90% of the prostate gland).
Results
According to our data, the 5-year disease-free survival was
significantly higher in the patients who received radiation dose D90 > 140 Gy,
than in patients with dose < 140 Gy: 93.2% and 77.6%, respectively (p 140
Gy), but statistically signi ficant differences between the groups were obtained
only in the incidence of dysuria: 58.6% and 42.4%, respectively (p < 0.05).
Conclusion
Along with the stage of disease, tumor grade, and preoperative
PSA, PDA plays important role in the prognosis of the disease. In patients with
higher D90 biochemical control was better, although the frequency of dysuria in
this group of patients was more common.
B-0207 14:54
Ionizing radiation exposure as a result of diagnostic imaging in patients
with Hodgkin and non-Hodgkin lymphoma
M.P. Crowley, S.B. O'Neill, D.C. O'Neill, B. Bird, O. Flanagan, M.M. Maher,
M.R. Cahill, D. O'Shea, K. O'Regan; Cork/IE
Purpose: Exposure to ionizing radiation has been linked to an increased risk
of malignancy. An increasing majority of patients with lymphoma achieve long-
term survival. Late complications of treatment have emerged as a significant
cause of death/morbidity. Long-term survivors are at risk for developing second
malignancies due to treatment. Ionizing radiation exposure through diagnostic
imaging may increase this risk.
Methods
and Materials: Retrospective review of 486 consecutive patients
with biopsy-proven Hodgkin/non-Hodgkin lymphoma that discussed at a
multidisciplinary lymphoma meeting between January 2009 and July 2012 was
conducted. The number/type of radiological procedures were obtained from the
radiology databases in each of 5 participating centres. The cumulative effective
dose (CED)was calculated using standardised procedure-specific radiation
dose levels.
Results
Mean (SD) age at diagnosis was 59 (17) with 15% (n=73) under 40
years. 59% percent were men. 16% (n=78) had Hodgkin lymphoma; 84%
(n=408) had Non-Hodgkin lymphoma. The median estimated total CED (IQR)
per subject was 69.4mSv (42-118). 46% had a total CED > 75mSv and 14%
had a total CED > 150mSv. CT contributed 89% of the CED and PET-CT
contributed 8%. Patients aged under 40 had a median (IQR) CED of 89.44mSv
(55.42-123.94). Patients who underwent a stem cell transplant had a median
(IQR) CED at 161.94mSv (135.11-224.68). 59% of this group went on to have
radiotherapy as part of their treatment protocol.
Conclusion
This study highlights the considerable ionizing radiation exposure
from radiological imaging in lymphoma patients, especially in young patients
considered the most radiosensitive and at highest risk for secondary
malignancies.
B-0208 15:03
The role of baseline 18 F-FDG PET/CT maximum SUV in predicting
treatment outcome of patients with multiple or oligometastatic breast
cancer
H. Zagloul
1, Y. Assiri1, Y.E. Almalki2, S. El badawy1; 1Dammam/SA, 2Riyadh/SA
(
[email protected])
Purpose: To evaluate pretreatment (SUVmax) of (18 F-FDG PET-CT) as a
predictor of progression free survival (PFS), and overall survival (OS) in
multiple and oligometastatic breast cancer patients.
Methods
and Materials: We retrospectively analysed metastatic breast cancer
patients (MBC) who had pretreatment 18 F-FDG PET-CT from January 2010 to
December 2012. We examined the association between the highest
pretreatment (SUVmax) in metastatic sites and the treatment outcomes. The
(PFS), and (OS) were calculated by the Kaplan-Meier method, and log rank
test.
Results
We identified 70 MBC patients with pretreatment 18 F-FDG PET-CT.
Oligometastasis to bone was observed in 20 patients while 50 patients had
multiple organs metastases. The receiver-operating characteristic curve (ROC)
demonstrated a SUVmax 7.7 to be the cutoff in multiple MBC for predicting
PFS which was significantly higher in patients with pretreatment SUVmax 7.7
compared to > 7.7 (P
< 0.0001). On multivariate analysis (MVA), the SUVmax
category was the only factor correlated with both PFS (Hazard ratio (HR)) =
4.5, 95% C I 3-6.8, P < 0. 0001 ) and OS (HR = 3.2, 95% C I 2.2-4.9,
P 4.4 ( P =0.001 ). On MVA, the SUVmax category was the only factor
associated with PFS ((HR) = 8.4, 95% C I 1.2-54.8, P < 0. 026) and but not OS
(P=0.99).
Conclusion
The pretreatment 18 F-FDG PET-CT SUVmax is an independent
prognostic predictor of clinical outcomes in MBC patients.
B-0209 15:12
The malignant proliferation of MDT meetings: can radiology departments
continue to support them all?
R. Balasubramaniam, M. Subesinghe, J. Smith; Leeds/UK
(
[email protected])
Purpose: To quantify the increase in workload associated with multidisciplinary
team meetings for radiologists working in a tertiary referral centre over a 5-year
period.
Methods
and Materials: Information regarding volume of MDT cases from
2008 to 2012 was acquired from the radiology information system (CRIS
TM)
and through structured interviews of indi vidual consultant radiologists. Data
obtained included the number of MDT meetings involved with, type of MDT
meeting (oncological or non-oncological), time allocated for preparation and
perceived deficiencies in the current MDT meeting.
Results
The annual number of cases discussed in an MDT meeting in 2008
was 13049. In 2009, this had grown to 24610, by 2010 it was 26864, in 2011 a
peak of 28603 cases and in 2012 there were 26984 entries. This demonstrates
that the volume of cases has more than doubled over five years. Consultant
radiologists were responsible for a median of 2 MDT meetings per week (range
1-5). 66% (31/47) of consultant radiologists were part of an oncological MDT
meeting and 60% (28/47) prepared for at least part of their MDT meeting out of
contracted working hours. The most frequently stated deficiencies in the
current MDT meeting included insufficient clinical information (40%) and a lack
of clerical support/funding (32%).
Conclusion
The MDT approach is the standard of care in the delivery of
optimal oncological patient management in the UK. The radiologist's workload
associated with MDT meetings has more than doubled in the last 5 years. The
MDT meeting is under resourced and without change unsustainable.
B-0210 15:21
Multidisciplinary meetings and radiologist workload: a retrospective and
prospective review in a tertiary university centre in Ireland
E. Aherne, H. Moriarty, M. Egan, L. Lawler; Dublin/IE
(
[email protected])
Purpose: In recent years multidisciplinary meetings (MDMs) have become a
part of the standard of care for many patients with cancer. The number and
complexity of imaging studies presented continues to expand rapidly. These
meetings are an important forum for discussion and decision-making regarding
challenging cases and for clinical teaching but have put increasing pressure on
radiology departments in their demand for time and resources.
Methods
and Materials: Data was retrospectively gathered from April 2012 to
September 2012 regarding the number of MDMs held and type of imaging
reviewed. A five-week prospective study was performed from 22/10/2012 to
25/11/2012 inclusive to examine the workload in further detail.
Results
Retrospectively, 199 meetings were held with 2253 clinical cases
reviewed over 26 weeks. Prospectively, 52 meetings were held over 5 weeks
S180
BA C D E F G
Thursday
for 13 clinical specialty areas. There were 1038 clinical case discussions.
There were a total of 2122 documented individual imaging studies reviewed:
563 CT studies (27%), 446 ultrasound studies (21%), 411 mammogram
studies (19%), 264 MRI studies (12%), 113 PET studies (5%). Specialist
registrar preparation time was 55 hours (11 per week). Consultant preparation
time was 67.75 hours (13.55 per week). Delivery time was 57.25 hours (11.45
per week).
Conclusion
MDMs are becoming a standard of care for cancer patients. Due
to the rapid increase in the number of meetings and the volume and complexity
of cases discussed, MDMs now represent a significant proportion of the
radiologist workload and reduce the time dedicated to other activities within the
department.
14:00 - 15:30 Room F2
Breast
SS 202
Different ways to evaluate treatment
response
Moderators:
P.A.T. Baltzer; Vienna/AT
G.I. Kirova-Nedialkova; Sofia/BG
B-0211 14:00
Evaluation of T1/T2 ratios obtained by quantitative MRI in a pilot study as
a potential biomarker to monitor response to treatment of biopsy-proven
malignant breast lesions and assessment tool for involvement of
contralateral breast.
M.A. Malikova
1, J.N. Tkacz1, A. Aakil1, P.J. Slanetz1, C.-Y. Guo2, H. Jara1,
C.-Y. Guo2; 1Boston, MA/US, 2Tainan/TW (
[email protected])
Purpose: To study a potential role of quantitative MRI (qMRI)using T1/T2
ratios to assess contralateral breast involvement and monitor response to
treatment.
Methods
and Materials: In a pilot study, 28 women with known breast lesions
were scanned post-treatment with the mixed-TSE pulse sequence and T1/T2
maps were obtained. qMRI assessment of contralateral breast without known
cancerous lesion was performed and compared to the breast lesion subjected
to chemotherapy and/or radiation therapy to monitor treatment response.
Results
T1/T2 means of 6.73 ± 2.55 were observed for biopsy-proven
malignant lesions treated prior to qMRI with chemotherapy and/or radiation as
compared to contralateral breast with T1/T2 ratio means of 3.37 ± 1.68.
Recurrent disease with contralateral breast involvement was confirmed by
histophatology in two cases and elevated T1/T2=11.5 for previously treated
lesion (contralateral breast T1/T2 = 8.1) and T1/T2= 9.1 (contralateral breast
T1/T2= 6.9) were detected. The higher stage of cancer determined by
histopathology was strongly associated with higher T1/T2 ratio ( p= 0.0093).
Estrogen, progesterone and HER2/neu receptors triple-negative status were
associated with higher T1/T2 ratio and more poor response to treatment
(p=0.0065). Larger size of lesion showed significant correlation with elevated
T1/T2 ratio and poor response to treatment with chemotherapy alone
(p=0.0427) as compared to combination regimen with chemotherapy and
radiation.
Conclusion
The T1/T2 ratios provide measures that strongly correlate with
histopathology. This quantitative information can provide basis for
improvement of diagnostic breast imaging and serve as a tool to assess
response to treatment and contralateral breast involvement.
B-0212 14:09
Role of pre-treatment apparent diffusion coefficient in the prediction of
response to neoadjuvant chemotherapy in locally advanced breast
cancer patients
A. Cipriani, E. Bufi, P. Belli, M. Costantini, M. Di Matteo, P. Rinaldi, L. Bonomo;
Rome/IT (
[email protected])
Purpose: Being still no consensus in the literature about this topic, we
addressed the diagnostic reliability of apparent diffusion coefficient (ADC),
obtained before treatment, in the prediction of response to neoadjuvant
chemotherapy (NAC) in locally advanced breast cancer (LABC) patients.
Methods
and Materials: Two hundred fifty-five consecutive LABC patients
(mean age 47.7± 10.0 years, range 24-74 years) underwent a 1.5 T MRI
examination of the breast before and after NAC, prior to surgery, including
dimensional assessment of target lesi ons (according to RECIST criteria) and
diffusion-weighted imaging (DWI), with ADC calculation (b values 0 and 1000
sec/mm2). Response to treatment was assessed according to the TRG (tumour
regression grade) classification. Pre-treatment ADC and increase in ADC
values ( ,ADC) following NAC of responders and non-responders were
compared.
Results
Following NAC, pathological complete response (TRG1) was
observed in 17% of cases, partial response (TRG2-3) in 42% and no response
(TRG4-5) in the remaining 41%. ADC was capable of differentiating each
specific tumour subtype before treatment (anova, p=0.022). No difference was
observed between pre-treatment ADC of patients with partial or complete
response to treatment (TRG1-2-3) and non-responders (TRG4-5, p=0.581).
Otherwise, post-treatment ADC of responders was statistically higher than non-
responders (p < 0.001). Both final ADC and ,ADC inversely correlated with the
TRG class (Spearman's rho -0.373 and -0.315, respectively, p < 0.001).
Conclusion
In our experience, pre-treatment ADC does not predict response
to NAC in LABC patients. Otherwise, final ADC and ,ADC negatively correlate
with response to treatment and should be taken into consideration when
establishing it.
B-0213 14:18
Diffusion-weighted imaging to quantify the residual tumour post-
neoadjuvant chemotherapy in locally advanced breast cancer: in
comparison with dynamic contrast-enhanced MRI
S. Poyyamoli; Coimbatore/IN (
[email protected])
Purpose: Quantification of breast carcinoma after neoadjuvant chemotherapy
is essential to triage a locally advanced breast cancer (LABC) patient into
breast conservation. Diffusion-weighted imaging (DWI) is evaluated for residual
tumour assessment in comparison with dynamic contrast-enhanced MRI (DCE
MRI).
Methods
and Materials: Thirty-six patients with LABC were studied with DWI
and DCE MRI, before and after neoadjuvant chemotherapy. Tumour size and
Apparent Diffusion Coefficients (ADC) were recorded. The residual tumour
sizes measured at DWI and DCE MRI were compared with the size at post-
surgical pathology, which was considered gold standard, using Pearson
correlation. The pre-treatment ADCs of the tumour were compared between
those with pathological complete response (pCR) and those with residual
disease (non-pCR).
Results
The sensitivities and specificities for detection of residual tumour
were similar for both DWI and DCE MRI, at 100% and 80%, respectively. Both
DWI (r=0.94, p < 0.001) and DCE MRI (r=0.93, p < 0.001) had significant
correlation with tumour size at pathology with no significant difference between
their strengths of correlation (z=0.12, p=0.9045). DW MRI (z=0.797, p=0.425)
and DCE MRI (z=0.88, p=0.379) fared equally well among focal and nonfocal
lesions. There was no significant difference (p=0.5527) in the pre-treatment
ADCs between the pCR and non-pCR groups.
Conclusion
DWI is as accurate as DCE MRI in quantifying the presurgical
residual disease in patients with locally advanced breast cancer who undergo
neoadjuvant systemic therapy. It can be of use in patients with end-stage renal
disease. ADC analysis is not useful in tumour response prediction.
B-0214 14:27
The hypervascularity paradox: can asymmetric increase in breast
vascularity predict the response of neoadjuvant chemotherapy and the
follow-up outcome in locally advanced breast cancer?
M. Di Matteo, E. Bufi, A. Cipriani, M. Costantini, P. Belli, L. Bonomo; Rome/IT
Purpose: To investigate the relationship between asymmetric increase in
breast vascularity (AIBV) and the pathological and molecular profiles of breast
cancer. To address the prognostic performance of AIBV and of vascular maps
reduction after NAC (Neoadjuvant Chemotherapy) in predicting pathological
complete response (pCR) at surgery and outcome at follow-up.
Methods
and Materials: Two-hundred-nineteen patients with unilateral locally
advanced breast cancer (LABC) underwent MRI before and after NAC. Axial,
sagittal and coronal MIPs were obtained to allow a subjective comparative
evaluation. Asymmetrical vs. symmetrical breast vascularity was defined
through a combination of vessels number, di ameter and signal intensity. An
average 31.4 ± 18 months follow-up was available for 82 patients.
Results
AIBV ipsilateral to the LABC was observed in 62.5% of cases
(p < 0.001). AIBV was also significantly associated with IDC, G3, Triple
Negative, HER2+, and Hybrid phenotypes (p < 0.001). pCR was higher among
the LABC with ipsilateral AIBV (24%) than those with symmetrical breast
vascularity (6%) (p= 0.001; t=-3.395). After NAC, vascular map in the breast
with LABC was significantly reduced, particularly in patients with pCR
(p < 0.001; t=-4.803). At follow-up, a 22% recurrence-rate was observed (6.1%
mortality). AIBV after NAC was significantly associated with worse overall
survival at follow-up (Kaplan-Meier analysis).
Conclusion
LABC with ipsilateral AIBV before NAC is associated with more
aggressive clinical, pathological and molecular profiles. Nonetheless, it is more
sensitive to NAC and shows a higher frequency of pCR. Consistently, the
presence of AIBV after NAC entails a worse late prognosis and should prompt
more aggressive therapeutic strategies.
S181
BA C D E F G
Thursday
B-0215 14:36
Accuracy of 3 T magnetic resonance imaging (3 T MRI) with a high-
relaxivity contrast agent in assessing treatment response in patients
undergoing neoadjuvant chemotherapy (NAC)
M. Telesca, F. Pediconi, S. Ursu, M. Luciani, V. Casali, E. Miglio, C. Catalano;
Rome/IT (
[email protected])
Purpose: To assess the accuracy of 3 T MRI in evaluating residual disease
after NAC in patients with advanced breast cancer.
Methods
and Materials: Between March 2010 and March 2013, 47 women
with advanced breast cancers underwent 3 T MRI before and after NAC. The
MRI protocol comprised precontrast FSE T2w IDEAL sequence and VIBRANT
3D T1w sequence acquired before and after administration of gadobenate
dimeglumine (MultiHance®) at 0.1 mmol/kg bodyweight. Tumour size was
determined before and after NAC. MRI evaluation of treatment response was
classified with RECIST criteria. Pat hologic complete response was defined as
when there were no residual invasive cancer cells. Residual tumour size at
MRI was compared with pathological findings.
Results
50 lesions were evaluated. The overall sensitivity, specificity, PPV,
NPV and accuracy for diagnosing of invasive residual disease at MRI were
70%, 76%, 85%, 57% and 72%, respectively. The presence of residual tumour
at MRI was overestimated in 4 cases (in 2 cases histology showed only DCIS
component) and underestimated in 10 cases (histology showed scattered
residual invasive foci). We found a statisti cally significant correlation between
MRI and pathology measurements (Spearman Rho = 0.639; P value < 0.0001).
The tumour size was underestimated in 11 cases, in all of these the
histological size was less than 4 mm.
Conclusion
The presence and size of residual disease in breast patients
treated with NAC could be accurately evaluated using 3 T MRI and high-
relaxivity contrast agent. Both overes timation and underestimation can be
observed and might have important clinical impact.
B-0216 14:45
Locally advanced breast cancer response to neoadjuvant chemotherapy:
correlation between RECIST, positive enhancement integral values and
tumour vascularity
M. Nadrljanski, R. Maksimovic, V. Plesinac-Karapandzic, M. Nikitovic,
B. Markovic-Vasiljkovic, Z. Milosevic; Belgrade/RS
(
[email protected])
Purpose: To prospectively assess tumour size, vascular score, positive
enhancement integral (PEI) on MRI and their correlation in patients with locally
advanced breast cancer (LABC).
Methods
and Materials: Thirty patients were assessed initially, after four
cycles of anthracycline-based regimen and upon NACT (paclitaxel, 4 cycles)
with 1.5 T unit, on Gd-DTPA postcontrast series. The following was analysed:
tumour size (RECIST), number of vessels (30 mm or longer, 2 mm or larger)
and PEI values (mean±SD), correlated to RECIST.
Results
Tumour size change is significant before and after four cycles
(4.7±1.5 cm vs. 3.2 ±1.1 cm, p < 0.001) and upon NACT (4.7 ±1.5 cm vs.
1.9±0.9 cm, p < 0.0001). The same applies to vascularity after four cycles
(4.0±1.1 vs. 3.2 ±1.1, p < 0.001) and upon NACT (4.0 ±1.1 vs. 2.2 ±0.9,
p < 0.0001) and to PEI after four cycles (779.6 ±97.2 vs. 662.6±91.3, p < 0.001)
and upon NACT (779.6± 97.2 vs. 566.2 ±97.1, p < 0.0001). The correlation
between RECIST and vascularity/PEI is weak after four cycles (0.36 and 0.22
respectively) and moderate upon NACT (0.61 and 0.50 respectively). Upon
NACT, the correlation between vascularity and PEI is weak (0.33), unlike the
strong correlation of tumour size after four cycles and upon NACT (0.80).
Conclusion
Tumour size, vascularity and PEI significantly change during and
upon NACT. Change in tumour size after four cycles and upon NACT strongly
correlates. There is moderate positive correlation between RECIST and
vascularity/PEI upon completion of NACT, but not before paclitaxel was
introduced. To our knowledge, this is the first trial testing PEI in NACT.
B-0217 14:54
Breast MRI: factors affecting accuracy in the evaluation of residual
disease after neoadjuvant chemotherapy
S. Gigli, F. Di Pastena, S. Tardioli, M. Mancini, G. D'Amati, M. Monti,
L. Ballesio; Rome/IT (
[email protected])
Purpose: After Neoadjuvant Chemotherapy (NACHT)some changes occur in
the tumoral bed,reducing MRI accuracy in evaluating residual disease.We
aimed to analyse the causes of under/overestimation of lesions size in MR
images.
Methods
and Materials: We reviewed MRI exams of 69 patients with locally
advanced breast cancer and we measured the longest diameter of each lesion
on MR images obtained before and after NACHT.The response rate was
expressed in percentage and compared to the tumor size on the histological
specimen (expressed in percentage according to Miller and Payne).In absence
of residual tumor we classified the case as pathological complete response
(pCR). We used Pearson correlation and T-test to relate MRI and pathological
response rate.We stratified differences based on the histological changes in
the surgical specimen (fibrosis or necrosis).We also considered MRI
findings (mass/non mass like enhancement, hi gh T2 signal intensity) and tumor
biological features.
Results
23/69 patients achieved pCR.MRI identify pCR in 21/23 cases,in two
cases overestimate disease.We observed a good correlation (0.67)between
MRI and pathology ( t=6.1169; df =46; p
2.5 cm),non mass-like enhancement,Triple Negative cancers and
high T2 signal intensity.
Conclusion
MRI is a valid tool in evaluating pCR but tends to overestimate
lesions size in case of residual tumor.MRI accuracy in estimating tumor size
after NACHT depends on the presence of fibrous tissue,still vascularised,which
can enhance after contrast.It's very important to consider tissue changes
caused by chemotherapy in order to improve MRI accuracy.
B-0218 15:03
Role of MRI in predicting the response of neoadjuvant chemotherapy and
the follow-up outcome in patients with different breast cancer
phenotypes
E. Bufi, M. Di Matteo, P. Belli, L. Nardone, B. Diletto, L. Bonomo; Rome/IT
Purpose: We addressed the diagnostic reliability of conventional MRI vs.
Diffusion Weighted Imaging (DWI) according to different tumor subtypes,
including HER2+/HR+ (Hybrid phenotype) and in the prediction of outcome at
follow-up.
Methods
and Materials: Two-hundred-twenty-five patients underwent MRI
before and after NAC, including morphological assessment (RECIST
classification) and DWI with ADC. The complete pathological response - pCR
was assessed (Mandard classification). An average 31.4 ± 18 months follow-up
was available for 82 patients.
Results
Tumor phenotypes were Luminal (63.6%), Triple Negative (16.4%),
HER2+ (7.6%) or Hybrid (12.4%). After NAC, pCR was observed in 17.3% of
cases. Average ADC was statistically higher after NAC (p < 0.001) among
patients showing pCR vs. those who had not pCR. The RECIST classification
showed adequate performance in predicting the pCR in Triple Negative (area
under the ROC curve, AUC=0.9) and in the HER2+ subgroup (AUC=0.826).
Less accurate performance was found in the Luminal and Hybrid subgroups
(AUC 0.693 and 0.611, respectively). In the latter two, the ADC criterion
yielded an improved performance (AUC=0.787 and 0.722, respectively). At
follow-up, a 22% recurrence-rate was observed (6.1% mortality); no recurrence
was observed among pCR patients. None of the above-mentioned MRI criteria
predicted disease-free survival (Kaplan-Meier survival analysis).
Conclusion
The diagnostic reliability of MRI in predicting the pCR to NAC
depends on the tumor phenotype, particularly in the Luminal and Hybrid
subgroups. In these cases, the ADC value may facilitate the diagnosis.
Nonetheless, disease-free survival at follo w-up can be predicted through final
histopathological results only.
B-0219 15:12
MRI evaluation for residual diseases after the lumpectomy of malignant
breast tumours
L. Wang, D. Wang; Shanghai/CN (
[email protected])
Purpose: To determine the utility of breast magnetic resonance imaging (MRI)
in detecting residual diseases at the prior lumpectomy site.
Methods
and Materials: From September 2009 to June 2013, 87 consecutive
patients who underwent lumpectomy and were pathologically confirmed as
malignant tumours were retrospectively reviewed. All the patients underwent
MRI before re-excision surgery. All scans were evaluated according to BI-
RADS criteria of MRI for post-surgery.
Results
Of the 87 patients, residual diseases were pathologically confirmed in
28 (32.2%) patients. Forty-two patients had BI-RADS 2 or 3 category, among
of which, 4 (9.5%) had residual lesions and 50% (21/42) patients had
undergone breast conservation therapy; Forty-five patients had BI-RADS 4 or 5
category, among of which, 24 (53.3%) had residual lesions and 8.9% (4/45)
patients had undergone breast conservation therapy. The sensitivity,
specificity, positive predictive value a nd negative predictive value of MRI for
prediction of residual cancer were 85.7% (24/28), 64.4% (38/59), 53.3%
(24/45) and 90.4% (38/42), respectively. Among the MRI findings, ductal
enhancement, segmental enhancement and masslike enhancement had a
positive predictive value of 77.8%, 71.4% and 54.5%, respectively.
Conclusion
BI-RADS categories of MRI were useful in estimating the residual
lesions after lumpectomy. Ductal enhancement, segmental enhancement and
masslike enhancement were most predictive of malignancy.
S182
BA C D E F G
Thursday
B-0220 15:21
Image-guided breast lesion excision biopsy versus vacuum-assisted
breast biopsy for suspicious non-palpable breast lesions
N.M. Abdel Razek, M. Shaalan, O. Yousef, O.S. Omar, S. Naguib, O. Soliman;
Giza/EG (
[email protected])
Purpose: To compare the diagnostic efficiency of BLES to VAB in diagnosis of
small non-palpable suspicious breast lesions.
Methods
and Materials: This is a prospective study included 380 patients with
small suspicious non-palpable breast lesions (BIRADS 4 & BIRADS3 with
positive family history).190/380 were performed using the BLES &190/380
were performed using the VAB.The histopathology results were analysed and
compared to the results of open surgery in the malignant cases.
Results
Group 1 included 190 suspicious lesions were removed using the
BLES ,20%(55/190)were diagnosed after histopathology as benign including
fibrocystic disease,sclerosing adenosis ,radial scars and papillomas without
atypia.31.6%(60/190)were diagnosed as high risk lesions including papillomas
with atypia,ALH,ADH&39.4 (75/190)were diagnosed as malignant including
DCIS, LCIS,IDC&ILC.All histopathologically proven malignant lesions were
exposed to Re-surgery.there was no underestimation encountered by the
BLES.The margin was free in 68% of cases (51/75 malignant lesions)and the
margin was flushed in 32%(24/75)of malignant cases.Group 2 included another
190 suspicious lesions removed using the VAB,33.7%(64/190) were
benign,30.0%(57/190)were high risk lesions & 36.3 %(69/190)were malignant
lesions.All malignant lesions were exposed to re-surgery.Underestimation after
VAB was encountered in 20.5% (39/190) of cases.Underestimation of DCIS
diagnosed by VAB was found in (12/25)48.0%.
Conclusion
BLES & VAB are used as the primary method for histopathology
diagnosis of suspicious small&borderline lesions.BLES is favored in high risk
lesions & DCIS considering the relativ e high underestimation rate associated
with VAB and not found with the BLES. Moreover, BLES offers complete lesion
removal with available margin evaluation offe ring good results similar to that of
open surgery.
14:00 - 15:30 Room G/H
Genitourinary
SS 207
Uterus: imaging and intervention
Moderators:
T.J. Kroencke; Berlin/DE
I. Thomassin-Naggara; Paris/FR
B-0221 14:00
MRI in cancer of the corpus uteri staging: possibilities and limitations
A. Proshin, J. Proshina, T. Berezovskaya; Obninsk/RU
(
[email protected])
Purpose: To prospectively assess the diagnostic capabilities of magnetic
resonance imaging (MRI) in the detection of local extent of endometrial
carcinoma (EC) and to determine the causes of errors in evaluation of depth of
myometrial invasion.
Methods
and Materials: 72 consecutive patients with a histologically proven
EC underwent preoperative MR imaging. 1.5 Tesla unit (Symphony Maestro
Class, Siemens, Erlangen, Germany) was used with a multichannel phased-
array body coil. High-resolution T2-WI in three planes were obtained, followed
by T1-WI after intravenous contrast administration in 30 patients. MR findings
were compared with surgical staging.
Results
Total accuracy of MRI for EC staging was 84%. For deep myometrial
infiltration, a sensitivity of 56%, specificity of 92%, PPV of 69% and NPV of
87% were reached. Accuracy for contrast-enhanced scans and T2 sequences
showed no statistically significant difference. Accuracy of MRI for cervical
involvement detection was 95%. Errors in evaluating myometrial invasion were
retrospectively divided into three groups. Cases of misdiagnosis associated
with methodological errors (motion artefacts, wrong slice positioning, MRI
performed in early period after curettage) were combined into the first group.
Other errors were associated with concomitant pathologies (adenomyosis and
leiomyomas) and age-related changes of the corpus uteri. Tumour-related
factors (large polyploid tumours, tumours located in the uterine cornu, some
histological types of tumour) were combined into the third group.
Conclusion
MR imaging is an effective technique for preoperative evaluation
of EC. A number of errors must be taken into consideration to avoid
misdiagnosis.
B-0222 14:09
The preserved fundal circumferential contour sign: a new and simple
sign on 2D ultrasound to differentiate septate uterus from other double
uterine cavity anomalies
R.M.K.E. Fouad, S.T. Hamed, I. Faker; Cairo/EG (
[email protected])
Purpose: To compare between the circumferential contour sign (CCS) and the
fundal contour sign (FCS) in the diagnosis of septate uterus.
Methods
and Materials: This study included 96 patients. Inclusion criteria
included the presence of duplicated uterine cavity on ultrasound study. The
CCS was assessd in axial images taken at the level of the fundus on 2D
ultrasound. Patients were classified into 2 groups. Group A showed a
preserved CCS, with no external indentations. The postulated diagnosis was
'septate uterus'. Group B included patients with disrupted CCS with a figure of
8 configuration. Findings were then correlated with the FCS on T2 W MRI
coronal images and laparoscopy. Accuracy measures were calculated and
compared.
Results
Group A (56 cases, 58.3%) included 49 (51%) true positive septate
uteri and 7 (7.3%) false positive cases. Group B (40 cases, 41.7%) included 36
(37.5%) true negative cases and 4 (4.2%) false negative cases. Ultrasound
diagnosis based on the circumferential contour sign showed significant
correlation with the laparoscopy diagnosis of the patients (p: 0.00). Calculated
sensitivity, specificity, positive and nega tive predictive values and accuracy of
ultrasound in reference to the CCS were 92.4%, 83.7%, 87.5%, 90% and
88.5%, respectively, as compared to 100%, 81.8%, 86.6%, 100% and 91.6% to
FCS.
Conclusion
2D ultrasound was considered inaccurate in investigating
duplicated uterine cavity anomalies due to its inadequacy in viewing the uterus
in the coronal plane. The CCS assessed on the axial images has upgraded the
performance of 2D ultrasound to compete efficiently with MRI and 3D
ultrasound.
B-0223 14:18
Accuracy of MR imaging in the diagnosis of invasive placenta
L.J. Bour, V. Place, S. Bendavid, Y. Fargeaudou, D. Sebag-Ffez, E. Vicaut,
A. Dohan, P. Soyer; Paris/FR (
[email protected])
Purpose: The purpose of our study was to evaluate the accuracy of MR
Imaging in the diagnosis of invasive placenta.
Methods
and Materials: The MR imaging examinations of 32 women with
suspected invasive placenta were blindly reviewed by four independent
observers. Eleven morphological MR criteria were evaluated using logistic
regression analysis. Final diagnosis obtained with MR imaging and diagnosis
confidence were investigated for each reader. Final diagnosis was established
by intraoperative findings or histopathological analysis.
Results
Sixteen women (16/32; 50%) had invasive placenta. Sensitivity,
specificity and accuracy of reviewers ranged between 76%-93%, 78%-83%
and 78%-88%, respectively. Overall sensitivity, specificity and accuracy of MR
imaging were respectively 80% [95%CI: 66%-93%], 84% [95%CI: 75%-94%]
and 82% [CI95% 78%-88%]. Overall interobserver correlation coefficient was
fair ( 5appa =.40). At univariate analysis, 5 morphological MR criteria were
significantly associated with the diagnosi s of invasive placenta (interruption of
the uteroplacental interface, p <.0001; interruption of the inner layer of the
uteroplacental interface on T2-weighted images, p=.0004; loss of the normal
uterine pear shape, p=.0004; intraplacental dark bands on T2-weighted
images, p=.0023; and placenta previa, p=.0131). At logistic regression
analysis, interruption of the uteroplacental interface was the single criteria that
was significantly associated with the diagnosis of invasive placenta (p=.0006;
OR=11.8).
Conclusion
MR imaging has acceptable degrees of sensitivity and specificity
for the diagnosis of invasive placenta, although it is associated with a fair
interobserver agreement. Interruption of the uteroplacental interface is the
single independent discriminating criteria for the diagnosis of invasive placenta.
B-0224 14:27
Nulliparous vs caesarean-scarred uteri: in-vivo analysis of myometrial
uterine fibres with 3 T-magnetic resonance with diffusion tensor imaging
(MRDTI)
F. Fiocchi, E. Petrella, S. Currà, L. Nocetti, F. Facchinetti, P. Torricelli;
Modena/IT (
[email protected])
Purpose: To investigate fibre architecture of in-vivo human uterus in
nulliparous and caesarean-scarred (CS) women by 3 T-MRDTI with 3D
tractography. Quantitative results regarding fibres number, Fractional
anisotropy (FA) and Apparent Diffusion Coefficient (ADC) were compared.
Methods
and Materials: In-vivo 3 T-MRDTI was performed in 56 volunteers
(12 nulliparous, I group; 44 CS, II group). Main diffusion directions reflecting
fibres orientation were investigated using sense-SSEPI sequence with
diffusion-sensitized gradients (b=600 mm2/s) along 16 directions within 24-
months after delivery. A fibre-tracking post -processing algorithm was used to
S183
BA C D E F G
Thursday
analyse quantitatively uterine structure. Fibres running through anterior
isthmus, site of suture, were compared to those running through posterior wall;
FA and ADC of whole uterus and of anterior isthmus were measured.
Results
3 T-MRDTI with 3D tractography reconstruction shows fibre disarray
at scar level. In group II significant reduction of longitudinal myometrial fibres of
anterior isthmus was found respect to posterior wall at the same level in
comparison to group I, p 0.1) in
group.i. and group II, respectively 0.406 ±0.025 versus 0.39± 0.038 and
3.364±0.456 x10-3 mm2/s versus 3.332 ±0.309 x10-3 mm2/s. Regarding
anterior isthmus region, ADC was higher in group.i. respect to group II,
although not statistically significant (p=0.1) as well as FA (p > 0.1).
Conclusion
3 T-MRDTI with fibre tracking adds in-vivo evaluation of uterine
muscular structure, quantifying fibre scar disarray. Further data and follow-up
will define how this up-to-date technique could impact in the clinical
management of VBAC delivery.
B-0225 14:36
3 T-magnetic resonance diffusion tensor imaging (MRDTI) of caesarean
scar: morphological and quantitative evaluation - what can we add to
transvaginal ultrasound?
F. Fiocchi, E. Petrella, S. Currà, L. Nocetti, T. Costi, G. Ligabue, F. Facchinetti,
P. Torricelli; Modena/IT (
[email protected])
Purpose: To investigate the potential value of 3 T-MRDTI with fibre-tracking
compared to Transvaginal Ultrasound (TVU) in caesarean scar (CS) evaluation
in women with one or two caesarean deliveries.
Methods
and Materials: 3 T-MRDTI and TVU were performed in 44
caesarean-scarred volunteers within 24 months after delivery (29 with one CS,
group I, and 15 with two CS, group II). Main diffusion directions reflecting fibres
orientation were investigated using a sense-SSEPI sequence with diffusion-
sensitized gradients (b=600 mm2/s) al ong 16 directions. CS was classified
liner or retracting on the basis of MR (linear if endometrial profile was
conserved; retracting if myometrial reduction/endometrial dehiscence were
found). A fibre-tracking post-process ing algorithm was used to analyse
quantitatively fibres of anterior isthmus compared to those of posterior wall.
Results
According to 3 T-MR, 21 CS were classified as linear and 23 as
retracting with TVU global agreement of 54.5%. Uterine isthmocele was found
in 8 women (4 each group; agreement 75%). 3 T-MRDTI fibre-tracking analysis
of myometrial fibres running through CS in anterior isthmus respect to posterior
wall showed no significant difference in fi bre disarray between group.i. and II (-
55%,IQ-32%-74% versus-42%,IQ-31%-58%,p > 0.4). Among uteri with
retracting CS, fiber reduction was significantly higher compared to those with
linear CS (-55%,IQ-37%-83% versus -40%,IQ-4%-61%, p < 0.001). At
follow-up, 7 women of group.i. had vaginal delivery; median fibre reduction was
-43%, lower respect to the median of group.i. (p=0.1).
Conclusion
3 T-MRDTI with fibre-tracking approach adds quantitative data at
morphological analyses of TVU, relying on evaluation of residual fiber muscle
at scar level.
B-0226 14:45
Quantitative dynamic contrast-enhanced MRI in symptomatic uterine
fibroids and normal uterus
S. Majd, B.J. Abdullah, S. Ahmad Sarji, N. Mat Adenan, C. Yeong;
Kuala Lumpur/MY (
[email protected])
Purpose: Quantitative dynamic contrast-enhanced MRI (DCE-MRI) is an
imaging technique to measure permeability and vascularity of the tissues. The
aim of this study was to compare the Ktrans, Kep and Ve of normal
myometrium with the fibroids.
Methods
and Materials: 16 normal subjects underwent DCE-MRI study of the
pelvis. After routine pelvis MRI protocol DCE-MRI was done using T1
volumetric (LAVA) sequence. The data were post-processed by DCE-MRI
software and parameters [K-trans: volume transfer between the blood plasma
and extracellular fluid, Kep: Rate constant between the EES and blood plasma,
Ve: EES fractional volume] were determined for the myometrium, endometrium
and cervix. 16 patients with clinical diagnosis of uterine fibroids were examined
using the same DCE-MRI protocol. Hysterectomy was performed after MRI and
uterine fibroids were confirmed by histopathology results. The Ktrans, Kep and
Ve of normal myometrium and fibroids were compared.
Results
The mean ktrans in myometrium and endometrium were 0.45 min-1,
0.40 min-1 in cervix and 0.80 min-1 in fi broids. There is significant difference (P
value < 0.05) between the K-trans of fibroid tissue and normal myometrium.
There was no significant difference between k-trans, Kep and Ve of
myometrium, endometrium and cervix.
Conclusion
The significant difference (P value < 0.05) between the K-trans of
fibroid tissue and normal myometrium indicates that the permeability of fibroid
tissue is higher than normal myometrium. It also supports the role of DCE-MRI
in functional assessment of tumour microcirculation. These findings may
provide the foundation for interpretation of results of uterine DCE-MRI studies.
B-0227 14:54
Magnetic resonance-guided focused ultrasound (MRgFUS) in women
affected by uterine fibroids: outcomes on symptoms, quality of life, non-
perfused volume ratio and size reduction over 12 months
F. Ciolina, F. Zaccagna, F. Boni, B. Cavallo Marincola, F. Sandolo,
L. Bertaccini, A. Napoli, C. Catalano; Rome/IT (
[email protected])
Purpose: To investigate the efficacy of MR-guided acoustic ablation in
symptoms relief and volume reduction over time.
Methods
and Materials: 120 fibroids in 95 symptomatic women (average age
40.8) were ablated using MRgFUS. Treatment is done using the ablative
properties of the HIFU system under 3 T MRI guide. Symptoms and quality of
life were scored using Severity Score (SS) and the Uterine Fibroids Score
Quality of Life Score (UFS-QOL). Pre-treatment measurements of leiomyoma
volume were obtained on pre-treatment MR images and immediately after
treatment non-perfused Volume (NPV) was calculated from T1-w contrast-
enhanced MR sequences. The average volume of treated fibroids was
84.76 ± 84.78 mm3. Follow-up images were obtained 3, 6 and 12 months after
treatment and served to determine leiomyoma shrinkage. Qualitative and
quantitative relations between fibroid volume, NPV ratio at treatment, 3, 6 and
12-months shrinkage were measured.
Results
MRgFUS treated patients results in a significant change in USF-QoL
score: mean SS score values were 48.6 ± 13.4 (pre-treatment), 25.1 ± 8.9
(three-months follow-up), 22.1 ± 7.5 (six-months follow-up) and 19.3 ± 6.8
(twelve-months follow-up). Fibroids volume changed from 84.76 ± 84.78 mm3
(before treatment) to 54 ± 66.1 mm3 (at 12 months follow-up). We encountered
a statistically significant difference be tween the two values (p = 0.001). Mean
post-treatment VNP was 59.90±56.47 mm3 (p=0.001).
Conclusion
Patients treated using MRgFUS therapy showed a significant
relief of symptoms and significant fibroi d ablation. The procedure is performed
in a totally non-invasive manner and with a high safety profile.
B-0228 15:03
Retrospective evaluation of uterine fibroids treated using MRgFUS:
elements that can predict short and long-term results
F. Ciolina, F. Boni, F. Zaccagna, V. Noce, L. Bertaccini, B. Cavallo Marincola,
A. Napoli, C. Catalano; Rome/IT (
[email protected])
Purpose: To retrospectively analyse predictive elements to obtain an optimal
treatment of uterine fibroids in patients treated using magnetic resonance-
guided focused ultrasound (MRgFUS).
Methods
and Materials: 75 fibroids (52± 18 mm) in 68 symptomatic women
(age average 41 ±5) were treated using MRgFUS (ExAblate 2100) combined
with a 3 T MR unit (GE). T2 SI of fibroids and T1 SI were measured on pre-
treatment examination before and after administration of gadolinium (Gd-
BOPTA, Bracco); also the distance between center of myoma and skin, skin
thickness, maximum diameter and volume of fibroids were recorded. The day
of treatment the non-perfused volume (NPV) was recorded at the end of the
treatment. All parameters were related to final NPV and volume shrinkage at
12 months to established short and long term outcomes of treatment.
Results
Difference between T1 SI of the fibroids and healthy myometrium
significantly correlates with volume shrinkage (45%) and NPV (60%, r=0.85).
T2 SI on pre-treatment studies, distance between skin surface and center of
myoma (53±19 mm) and skin thickness (13 ±7 mm) show a mild correlation with
volume reduction at 12 months (36+18 mm, respectively r=-72.5 p=0.047 and
r=69.7 p=0.03). Each sonication was of 20 ±2 s (2540± 1095 J/sonication) and
mean average duration of treatment was of 125 ±30 min. Moreover, there was
positive correlation between measured parameters, sonication duration and
energy necessary to obtain a > 50% NPV (70±15%, r= 62.8, p=0.021).
Conclusion
SI ratio on T1w of uterine fibroids and myometrium on screening
MRI should be considered as predictor of positive outcome for MRgFUS.
B-0229 15:12
Value of parametric maps in the assessement of uterine lesions by
combination of DWI and semi-quantitative perfusion dynamic contrast-
enhanced (DCE) MRI
A.C. Cadonici, D. Ippolito, O. Minutolo, P. Bonaffini, C. R.G.L. Talei Franzesi,
S. Sironi; Monza/IT (
[email protected])
Purpose: To investigate the value of combined diffusion-weighted imaging and
DCE-MRI in the assessement of benign and malignant uterine lesions.
Methods
and Materials: We enrolled 50 patients with endometrial cancer who
underwent pre-operative MR examination on 1.5 T magnet: scanning protocol
included multiplanar T1- and T2-weighted TSE,10 dynamic gadolinium-
enhanced T1-weighted GE sequences (overall time 5 min, 66 sec) and DWI
sequences (b value: 0.1000 mm 2/s). ADC and perfusion maps were generated
on dedicated workstation and regions of interest (ROIs) were manually drawn
on each identified uterine lesion and on normal myometrium. Mean ADC,
relative enhancement (RE, %), maximum enhancement (ME, %), maximum
S184
BA C D E F G
Thursday
relative enhancement (MRE, %) and time-to-peak (TTP, sec) were calculated
and statistically analysed.
Results
Post-operative histological ex amination confirmed the presence of
endometrial cancer in all the patients and the presence of 23 miomas. The
following parameters were obtained for neoplastic tissue: ADC
916.05 mm²/sec± 313.8 x10-3; RE 72.25% ± 33.9; ME 976.8% ± 331.7; MRE
90.9% ± 24.1; TTP 192.1sec ± 100.6, in miomas: ADC
1025.5 mm²/sec ± 436.1; RE 95.1% ± 48.6; ME 1357.3% ± 798.7;MRE
107.4% ± 47; TTP 233.8 sec ± 126.3 and in normal myometrium: ADC
1548.9 mm²/sec ± 277.6; RE 163.3% ± 34.2; ME 2010.1% ± 291.7; MRE
170.7% ± 31.2; TTP 242.8 sec ± 121.5. Mean ADC, RE, ME and MRE were
significantly lower ( p> 0.05) both in neoplasms and in miomas than in normal
miometrium, no significant difference was found between miomas and
neoplastic lesions.
Conclusion
Combined DWI and DCE-MRI offer in vivo information that can
be useful in depiction and characterisation of uterine lesions.
B-0230 15:21
Diagnostic value of ontrast-enhanced perfusion MR imaging in the
assessment of tumour grading in patients with endometrial carcinoma by
using quantitative analysis of microvascular changes: preliminary results
O. Minutolo, D. Ippolito, A. Cadonici, C. R.G.L. Talei Franzesi, P.A. Bonaffini,
S. Sironi; Monza/IT (
[email protected])
Purpose: To determine diagnostic value of dynamic contrast-enhanced
perfusion-MRI in detection and characterisation of endometrial
cancer,correlated with tumor grading,being the histopathological analysis the
standard of reference.
Methods
and Materials: From January 2011 to July 2012.80 patients with
histologically proven endometrial ca rcinoma underwent dedicated pelvic MRI
examination by using pelvic phased array multicoil.Each patient scan consists
of multiplanar T2 and T1 sequences and dynamic contrast enhanced
THRIVE,using a 1.5 T MRI system (Achieva,Philips).Philips's workstation was
used to generate color permeability maps showing perfusion of enhancing
tumors.After the placing of regions of interests (ROIs)on the site of maps which
best corresponded to enhanced regions of lesion,the following parameters
were calculated:Relative Enhancement,Maximum Enhancement,Maximum
Relative Enhancement and Time to Peak.
Results
Pathological results of all patients were obtained postoperatively and
compared with DCE-MRI perfusion parameters.At histological examination 21
patients had G1 tumor,44 had G2 tumor,14 had G3 tumor,and 1 had
squamous cell carcinoma.Tumor locations visualised on T2w MRI and DSCE-
MRI were consistent with histopathologi cal findings and the quantitative
analysis showed the following values for endometrial
cancer:RE (%)61.4±36.4;ME (%)829.4±418.8;MRE (%)69.4±42.2 and
TTP (sec)179.5±27.4.Corresponding values calculated in normal endometrium
were:RE (%)157.1±61.3;ME (%)1634.5±625.7;MRE (%)128.8±51.6 and
TTP (sec)193.6±23.8.A significant (p < 0.001)decrease of RE,ME and MRE in
the area of tumor lesion in all of the patients examinated in comparison with
the normal myometrium was observed.Furthermore a significant higher
values (p < 0.001)of RE,ME,MRE was obtained for G1 tumours (less
aggressive)in comparison with those with G2 or G3 grading.
Conclusion
Conventional MRI combined with perfusion DCE represents a
feasible technique that provide non-invasively quantitative and qualitative
information about biological characteristi cs of endometrial cancer,related to
tumor aggressiveness.
14:00 - 15:30 Room I/K
Neuro
SS 211
Stroke imaging
Moderators:
A.K. Firat; Malatya/TR
M.M. Thurnher; Vienna/AT
B-0231 14:00
Swirl sign is a robust predictor of spot sign on CTA and poor outcome in
ultra-early ICH patients
C. Ovesen, I. Havsteen, A. Christensen, C. Krarup, H. Christensen;
Copenhagen/DK (
[email protected])
Purpose: Computed tomography angiography (CTA) spot sign signifies active
bleeding and poor outcome in intracerebral haematoma (ICH) patients. CTA is
not as available as non-contrast CT (NCCT). NCCT swirl sign is a less well-
described marker of active bleeding. We investigate if swirl sign predicts spot
sign and poor outcome in ultra-early ICH patients?
Methods
and Materials: We included spontaneous ICH patients admitted
within 4.5 hours from symptom onset April 2009-January 2013. Standard
workup included NCCT and CTA. Swirl sign was defined as hypo- or isodense
regions within the hyperdense haematoma with brain parenchyma as
reference. Outcome was assessed as 90-day modified Rankin Scale (mRS).
Results
35 of 137 patients (25.5%) showed swirl sign and 27 (77%) had
concomitant spot sign. This yields a high specificity (0.92) and negative
predictive value (0.86) but slightly lower sensitivity (0.66) and positive
predictive value (0.77). Swirl sign independently predicted presence of spot
sign (OR 15.5 CI: 5.6-42.8) adjusted for admission haematoma volume and
time to scan. Swirl sign was associated with poorer median [IQR] 90-day mRS
(5 [4-6] vs. 3 [2-5], p < 0.0001). Swirl sign emerged as independent predictor of
poor outcome (mRS 5-6) (OR 3.28 CI: 1.15-9.34) adjusted for age, admission
NIHSS, and admission haematoma volume. Concurrent spot and swirl sign did
not add to the prediction of poor outcome.
Conclusion
Swirl sign predicts spot sign presence and entails poor outcome
irrespective of other predictors. Further studies are needed to evaluate the
swirl sign's value in clinical decision-making and trials.
B-0232 14:09
Intramural haematoma detection by susceptibility weighted image in
intracranial vertebral artery dissection
Y. Lee, H. Choi, S. Jung, K.-J. Ahn, B.-s. Kim, T.-W. Kim; Seoul/KR
(
[email protected])
Purpose: We aimed to evaluate accuracy of intramural haematoma sign on
susceptibility weighted image (SWI) in vertebral artery dissection (VAD).
Methods
and Materials: We retrospectively analysed patients with ischaemic
stroke in the vertebral artery territory from 2010 to 2012. We divided the
patients into VAD group and non-dissection group. Intramural haematoma sign
was considered positive if the patient had (a) eccentric or concentric
hypointense signal lesion in vertebral artery on SWI and (b) this signal should
be hyperintense on phase map and no evidence of calcification on the brain
CT suggesting blood products other than calcification. The accuracy of
intramural haematoma sign on SWI was evaluated. Phase value, demographic
and clinical data were compared between VAD and non-dissection group.
Results
Thirty-nine patients were included. Ten patients were VAD group and
29 patients were non-dissection group. Among 10 cases of VAD group, the
"Intramural haematoma sign on SWI" was positive in 9, and positive in 1 out of
29 cases in the non-dissection group. The intramural haematoma sign on SWI
was significantly associated with VAD (p < 0.001) and showed sensitivity of
90%, specificity of 96.6%. Mean phase values of intramural haematomas (n=9)
were all positive and those of calcified lesions (n=13) were all negative
(0.45±0.17 radian vs. -0.42±0.28 radian, p < 0.001).
Conclusion
The intramural haematoma sign on SWI was significantly
associated with VAD and the phase values were higher in intramural
haematomas compared with atherosclerotic calcifications.
B-0233 14:18
High-resolution MR imaging in patients with symptomatic middle cerebral
artery dissection
J. Byon, H.-S. Kwak, S. Hwang, K. Jung; Jeonju/KR
(
[email protected])
Purpose: To investigate the findings of high-resolution magnetic resonance
imaging (HRMRI) and clinical features in patients with acute symptomatic
middle cerebral artery (MCA) dissection.
Methods
and Materials: Ten patients with acute symptomatic MCA dissection
underwent HRMRI within 3 days after initial clinical onset and routine brain MR
imaging. HRMRI examinations include time-of-flight (TOF) MR angiography,
T2-weighted, T1-weighted, proton-density (PD)-weighted, and three-
dimensional magnetization-prepared rapid acquisition gradient-echo
(MPRAGE) sequences. MR angiography and/or cerebral angiography were
used as the reference standard to establish the diagnosis of MCA dissection.
We analysed the angiographic findings and HRMRI findings such as string
sing, peal and string sign, intimal flap, double lumen, and intramural
hematoma.
Results
All patients presented with cerebral ischaemia (median NIHSS score
= 2, range = 0 - 18). Nine patients excluded one with traumatic event, did not
have any history of trauma. The main site of the lesions was Lt M1 portion. On
TOF MR angiography and/or cerebral angi ography, string sign was seen in five
patients. However, intimal flap and double lumen findings were seen in all
patients on HRMRI. High signal lesion on MPRAGE sequences around the
dissection lumen due to intramural haematoma, was seen in three patients.
Conclusion
HRMRI can be able to easily detect the wall structure of MCA
such as the intimal flap and double lumen in patients with acute symptomatic
MCA dissection. MPRAGE can detect haemorrhage in the false lumen of MCA
dissection.
S185
BA C D E F G
Thursday
B-0234 14:27
Clinical significance of intraluminal contrast enhancement in patients
with spontaneous cervical artery dissection: an in vivo MRI study
E. Coppenrath1, O. Lenz1, N. Lummel1, J. Linn1, F. Bamberg1, M. Dichgans1,
T. Pfefferkorn2, M.F. Reiser1, T. Saam1; 1Munich/DE,
2Ingolstadt/DE (
[email protected])
Purpose: Recent studies have suggested that intraluminal thrombi show
strong contrast enhancement on carotid black-blood MRI. The aim was to
evaluate the significance of intraluminal contrast enhancement (iCE) on
symptom status in patients with spontaneous cervical artery dissection (sCAD).
Methods
and Materials: 33 consecutive patients (19 men) with sCAD
received a brain MRI (DIFF, T2w, T2*w, FLAIR, TOF) and a multi-sequence
3 T-MRI with fat-saturated high-resolution black-blood T1w-sequences pre-
and post-contrast, MRA, T2w- and TOF images of both carotid and vertebral
arteries. Presence or absence of iCE, vessel occlusion and vessel wall
haematoma (VWH) were analysed by two radiologists in consensus decision
who were blinded to all clinical information and the brain MRI.
Results
44 of 132 analysed vessels had a VWH, consistent with sCAD. In 17
of 44 dissected vessels an acute ischaemic stroke was found in the territory of
the corresponding vessel. 16 of 17 (94.1%) vessels ipsilateral to ischaemic
stroke demonstrated iCE, compared to 9 of 44 (20.4%) dissected vessels
without stroke in the corresponding vessel territory (Fisher´s Exact test
P < 0.001). The presence/absence of iCE for ischaemic stroke in dissected
vessels resulted in a sensitivity, specific ity, positive and negative predictive
value and accuracy of 0.94, 0.67, 0.64, 0.95, and 0.77 and an odds ratio of
32.0 (95% confidence interval = 3.64 - 281).
Conclusion
iCE, suggestive of intraluminal thrombus formation, is strongly
correlated with ischemic symptoms in patients with sCAD. Future studies will
have to determine whether patients with iCE are at greater risk of recurrent
stroke.
B-0235 14:36
CT-verified leukoaraiosis as risk factor for post-thrombolytic
symptomatic haemorrhage
L. Willer, I. Havsteen, A. Christensen, H. Christensen; Copenhagen/DK
(
[email protected])
Purpose: Is CT-verified leukoaraiosis a risk factor for symptomatic post-
thrombolystic haemorrhage?
Methods
and Materials: 1) Retrospective analysis of single-centre
consecutive TPA-treated patients within 4.5 hours from symptom onset.
Standard work-up included baseline non-contrast CT (NCCT) and CT
angiography and next day follow-up NCCT. Baseline NCCT leukoaraiosis was
graded using Fazekas' score and dichotomised as absence (Fazekas 0) or
presence (Fazekas 1-3). Haemorrhagic transformation was rated using ECASS
criteria. Symptomatic intracerebral haemorrhage (sICH) was defined as
haemorrhage and deterioration oh NIHSS 4 within 36 hours from symptom
onset. EVT-treated patients were excluded. 2) Pooled analysis with 1312 TPA-
treated patients from literature.
Results
311 TPA-treated were included April 2009 - July 2012. Leukoaraiosis
was present in 113 (36%). 23 (7%) showed haemorrhagic transformation (HT).
Leukoaraiosis positive patients had significantly higher haemorrhagic
transformation frequency (11.5%, p=0.04). Leukoaraiosis doubled HT risk (OR
2.4, 95% CI 1.4-5.8). Only 4 patients developed sICH, 3 with leukoaraiosis.
Leukoaraiosis was not an independent risk factor for haemorrhagic
transformation (p=0.2). Pooled analysis of 1623 patients in total, hereof 479
leukoaraiosis positive patients, showed significantly higher sICH frequency in
35 (7.3%) leukoaraiosis positive than 44 (3.8%) leukoaraiosis negative
patients, (p=0.005) and doubled sICH risk in leukoaraiosis positives (OR 1.97,
95% CI 1.22-3.19).
Conclusion
Leukoaraiosis is a risk factor for post-thrombolytic haemorrhagic
transformation and symptomatic haemorrhage.
B-0236 14:45
Analysis of association between carotid artery plaque volume and
cerebral microbleeds
L. Saba1, R. Montisci1, R. Sanfilippo1, M. Piga1, J. Suri2, E.A. Genovese1;
1Cagliari/IT, 2Roseville, CA/US (
[email protected])
Purpose: Cerebral microbleeds (CMBs), have become increasingly recognised
with the widespread use of MRI techniques that are sensitive to iron deposits.
Our purpose was to explore the association between carotid plaque volume
and CMBs.
Methods
and Materials: 82 consecutive (males 59; median age 64) patients
were prospectively analysed. Carotid arteries were studied using a 16-detector
row CT scanner whereas brain was explored with a 1.5 Tesla system. CMBs
were studied using a T2*-weighted gradient-recalled echo (GRE) sequence.
Microbleeds were classified as absent (grad e 1), mild (grade 2; total number of
microbleeds, 1-2), moderate (grade 3;total number of micro-bleeds,3-10), and
severe (grade 4;total number of microbleeds, > 10). Component types of the
carotid plaque were defined according HU values. Plaque volumes of each
component was calculated. Chi-square, multiple logistic regression analysis as
well as ROC was calculated.
Results
The prevalence of CMBs was 35.3%. A statistically significant
difference was observed between symptomatic (40%) and asymptomatic (11%)
patients (p value = 0.001; OR = 6.07). Linear regression analysis demonstrated
an association between the number of CMB and the symptoms (p = 0.0018). A
statistically significant correlation was observed between the increase of the
volume of the fatty component and CMBs (rho = 0.89; p = 0.001).
Conclusion
Results of this study confirm the association between CMBs and
symptoms and that there is an increased number of CMBs in symptomatic
patients. Moreover, we found that an increased volume of the fatty component
is associated the presence and number of CMBs.
B-0237 14:54
Symmetrical plaque progression rates in bilateral carotid atherosclerosis:
the impact of local plaque factors
H.-S. Kwak, G.-H. Chung; Jeonju/KR (
[email protected])
Purpose: The purpose of this study was to evaluate the symmetry of
progression or regression of bilateral carotid atherosclerosis during a seven
month follow-up period.
Methods
and Materials: As the placebo arm of a multi-center clinical trial, 54
subjects with 16-79% carotid stenosis by ultrasound and presence of a lipid
core on baseline MRI underwent follow-up carotid MRI at seven months. Wall,
lipid core, and plaque components such as intraplaque hemorrhage (IPH) and
ulcer were assessed on both sides on the baseline and follow-up scans.
Progression between bilateral carotid plaques was calculated as changes
within the common coverage between scans.
Results
Forty-three (79.6%) of the subjects were on lipid-lowering therapy.
Bilateral wall volume progression or regression was found in 31 subjects
(57.4%) and unilateral IPH was present in six (11.1%) subjects at baseline. In
the sample as a whole, there was little correlation in wall volume progression
between sides (r=-0.02, p=0.883). However, progression was significantly
correlated between sides in the group without IPH (r=0.31, p=0.034) and was
significantly different (p=0.011) than in the group with unilateral IPH (r=-0.60,
p=0.208). In those with IPH, mean progression was 29.9 ± 55.7 mm
3 on the
side with IPH and -26.9 ± 29.3 mm3 on the non-IPH side (p=0.131).
Conclusion
In the absence of intraplaque hemorrhage, carotid atherosclerotic
lesion volume tends to change in the same direction bilaterally, potentially due
to systemic processes.
B-0238 15:03
Diagnostic accuracy of whole-brain CT perfusion imaging in small-
volume infarctions
K.M. Thierfelder, L. von Baumgarten, A.C. Löchelt, F.G. Meinel, K. Nikolaou,
S.E. Beyer, M. Patzig, M.F. Reiser, W.H. Sommer;
Munich/DE (
[email protected])
Purpose: The aim of this study was to determine the diagnostic accuracy of
whole brain CT perfusion (WB-CTP) in small ischemic brain infarctions and to
identify factors influencing the detection rate.
Methods
and Materials: Out of a cohort of 1380 subjects who underwent
initial WB-CTP due to suspected stroke, we selected all patients with a
supratentorial MRI-confirmed ischemic infarction with a volume of 8 ml. The
study was designed as a case-control study with a ratio of cases to controls
with no infarction in follow-up MRI of 1:3. Two blinded readers independently
evaluated four different CT perfusion parameter datasets per subject with
respect to presence and localisation of a perfusion deficit.
Results
A total of 113 subjects met the inclusion criteria for the patient group.
Overall, WB-CTP reached a sensitivity of 43.4% and a specificity of 92.9%.
Among these, cortical infarctions were detected in 31 of 49 cases (69%), while
subcortical infarctions were detected only in 18 of 64 cases (28%), p < 0.05.
Mean final infarction diameter (17.3 mm) and volume (1.9 ml) of infarctions
detected on CTP were significantly larger than that of infarctions not detected
(12.4 mm and 0.8 ml, respectively; p < 0.001). Time from symptom onset did
not differ significantly between infarctions that were detected or not (204 vs.
189 min; p=0.75).
Conclusion
The detection rate of WB-CTP in small infarctions highly depends
on infarction localisation and final size, while time from symptom onset does
not seem to influence diagnostic accuracy.
S186
BA C D E F G
Thursday
B-0239 15:12
Dynamic CT angiogram in acute stroke: a complementary look at
perfusion
S. Chakraborty, S. Patro, R. Glikstein, G. Stotts; Ottawa, ON/CA
(
[email protected])
Purpose: CT angiogram and CT perfusion have been established as an
important tool for evaluation of the acute stroke patients. With the advent of
320 slice whole brain CT scanner, we are able to generate whole brain
perfusion and time resolved dynamic CT angiogram (dCTA) images that
provide temporal flow information.
Methods
and Materials: Retrospective assessment of 53 consecutive patients
presenting with acute stroke was performed. The dynamic CT angiogram 3D
MIP data are interpreted with documentation of the time of arrival of contrast at
the supraclinoid ICA, M1, M2 and distal corti cal branches at equivalent position
on each side. The filling of cortical branches is also analysed for antegrade or
retrograde flow.
Results
Correlation between the final volume infarct on follow-up CT scan
with the delay in appearance of contrast between sides at different vascular
levels was calculated using Pearson correlation coefficient. This was significant
at the cortical level (r= 0.7 p < 0.0001). Retrograde flow in cortical branches
was noted in 8 subjects. Most important observation in this study was the
exclusion of any significant infarct in presence of a symmetric dynamic CTA.
The smallest infarct size in presence of a delay in filling was 10.2 ml. In
patients with smaller infarcts, the dynamic CTA was symmetric.
Conclusion
dCTA is complementary to perfusion maps and enables us direct
visualisation of intracranial flow. Symmetric dynamic CTA is an excellent
predictor of very small or no infarct.
B-0240 15:21
20 minutes' door-to-needle time in acute ischaemic stroke is achievable
in a radiology-neurology team structure
S. Henriksen, L. Jeppesen, A. Christensen, H. Christensen; Copenhagen/DK
(
[email protected])
Purpose: We aimed at reducing our median door-to-needle-time (DTN) to
below 20 minutes by improving the org anisational structure of our acute stroke
evaluation while accepting no increase in bleeding complications.
Methods
and Materials: A team including radiologist, neurologist, stroke
nurse and radiographer set up a structured patient admission process based
on trauma team principles and experience with fibrinolysis. The team in a
dedicated room within radiology department receives the patients with
immediate access to both CT and MRI; standard work up is CT plus CTA.
During a 3-month registration period in 2013 an external person registered all
cases of acute stroke evaluation. For comparison, data from 2012 was used.
Results
A total of 148 patients was registered and was characterised by a
median age of 67 years and 53.4% males. Forty-seven patients (31.8%)
received fibrinolysis. The overall median DTN was 16 minutes 58 seconds. For
patients receiving fibrinolysis, the DNT was 20 minutes 58 seconds and for
patients not receiving treatment the median ti me to decision was 15 minutes,
50 seconds. No symptomatic intracranial haemorrhages or other significant
bleeding complications occurred during the study period. Median DTN in 2012
was 49 minutes; and costs were neutral.
Conclusion
DTN-time can safely be reduced to 20 minutes by organisational
interventions, in particular changing the auspice from neurological to
radiological. NNT is reduced by 1 with every 20 minutes reduction in DTN;
thereby this intervention has a clinically significant impact on stroke outcome.
Author Disclosures:
S. Henriksen: None. L. Jeppesen: None. A. Christensen: None. H.
Christensen: None.
14:00 - 15:30 Room L/M
Physics in Radiology
SS 213
Optimising image quality and patient
exposure in CT
Moderators:
P.E. Colombo; Milan/IT
W. Stiller; Heidelberg/DE
B-0241 14:00
Reconstruction of organ doses in paediatric CT performed in the 90-thies
in Norway
H.M. Olerud1, B. Toft2, S. Flatabø1, A. Jahnen3, C. Lee4, I. Thierry-Chef5;
1Østerås/NO, 2Gjøvik/NO, 3Luxembourg/LU, 4EPS Rockville, MD/US, 5Lyon/FR
(
[email protected])
Purpose: A large epidemiological study (EPI-CT) aims to provide knowledge
about the risk of leukemia and brai n cancer associated with pediatric CT,
http://epi-CT.iarc.fr/. New computational human phantoms and software have
been developed to provide estimates of the organ doses. The aim was to
reconstruct organ doses from CT examinations done in the 1990s with the new
software; to sort out the probable range of doses as input to uncertainty
estimates in EPI-CT.
Methods
and Materials: We used local typical scan protocols in Norway from
CT scanners used in the 1990s, and a beta version of the new software
provided for EPI-CT.
Results
A one year old child could have received 54 (17-77) mGy to the brain,
and 21 (7-31) mGy to active marrow from a head CT scan. From CT of the
chest, a newborn could have received 14 (10-21) mGy to active marrow. From
an abdominal CT scan, 10 year old children could have received doses of 10
(6-17) mGy to active marrow. These doses are considerably higher than the
age-adjusted protocols nowadays.
Conclusion
The doses children received from CT during the 1990s are of
such a magnitude that they might show statistically significant health effects in
the EPI-CT project. In Pre-PACS time there may be lack of knowledge about
the size of the child, the CT scanner model used, or the scan parameters used.
All these parameters result in differences in organ doses by a factor of 2 - 3.
Author Disclosures:
I. Thierry-Chef: Research/Grant Support; EU (FP7/2007-2013) under grant
agreement number 269912 - EPI-CT.
B-0242 14:09
Dose reduction with dual-energy body CT: feasib ility of concurrent
spectral analysis and dose modulation
I.S. Leichter, M.H. Gabbai, Z. Romman, J. Sosna; Jerusalem/IL
(
[email protected])
Purpose: Dose modulation (DOM) reduces patient dose by minimising x-ray
tube current according to patient size. The effectiveness of DOM is limited in
dual-energy CT (DECT) systems based on two tubes producing different
energies or energy-switching in one tube. Spectral-detector CT (SDCT)
technology uses only one x-ray beam separated into two energies by
innovative dual-layer detectors and should enable effective DOM. The purpose
of this study was to evaluate the feasibility of dose reduction in an SDCT
prototype.
Methods
and Materials: Following IRB approval and informed consent, 37
patients (mean age 56.6 years) were scanned with a novel-SDCT prototype
(Philips Healthcare, Cleveland, OH, USA). Eleven patients were scanned with
an abdomen/pelvis protocol, 14 with chest/abdomen/pelvis protocol, and 12
with a chest protocol. Scanning parameters were 120 kVp, mAs ranging from
59 to 259. Dose length product (DLP) and CT dose-index (CTDI
VOL) were
analysed for each patient to estimate dose savings (EDS).
Results
The estimated dose savings (ESD) was highest in chest scans
(22.4%), resulting in the lowest DLP and CTDI VOL values (363.6 mGy cm
,11.36 mGy, respectively). In chest/abdomen/pelvis scans dose saving was
lower (21.4%), resulting in 786.1 mGy cm and 13.2 mGy, respectively, and in
abdomen/pelvis scans it was lowest (14.8%), resulting in 807.0 mGy cm and
14.9 mGy, respectively. Dose saving was significantly higher for chest scans
and chest/abdomen/pelvis scans compared to abdomen/pelvis scans (p < 0.05
and p < 0.04, respectively).
Conclusion
SDCT can concurrently reduce patient dose substantially by
effective tube current modulation and enable full benefits of spectral analysis.
Author Disclosures:
Z. Romman: Employee; Philips. J. Sosna: Grant Recipient; Philips.
S187
BA C D E F G
Thursday
B-0243 14:18
Should automatic exposure control be used in CT imaging of pregnant
patients?
A. Papadakis, K. Perisinakis, J. Damilakis; Iraklion/GR
(
[email protected])
Purpose: To assess the effect of maternal body size at different stages of
gestation on maternal effective dose and embryo dose in routine abdomen and
pelvis CT imaging of pregnant patients using automatic exposure control
(AEC).
Methods
and Materials: The adult anthropomorphic Rando phantom was
used to simulate an average pregnant individual at the 1 st trimester of
gestation. The abdominal slices of the phantom were appropriately devised
using Lucite material to simulate pregnancy at the 2 nd and 3 rd trimester. Each
phantom was scanned with fixed mA and with the AEC-activated, using a 16-
row CT scanner. Thermoluminescent dosimeters were used to determine
absorbed dose at all maternal radiosensitive organs and embryo. Maternal
effective dose was calculated based on the ICRP 103.
Results
Maternal effective dose and embryo dose in fixed mA acquisitions
were 7.1 mSv and 18.6 mGy at the 1
st, 7.3 mSv and 17.7 mGy at the 2 nd, and
7.5 mSv and 15.4 mGy at the 3 rd trimester of gestation. The corresponding
values in AEC-activated acquisitions were 3.6 mSv and 7.5 mGy, and 3.9 mSv
and 8.8 mGy, and 4.2 mSv and 7.9 mGy, respectively.
Conclusion
AEC efficiency is not hampered by the increased abdominal size
of pregnant individuals. The AEC may substantially reduce maternal effective
dose and embryo dose even at the 3 rd stage of gestation when abdomen has
reached its maximum size. AEC should thus be activated without caution in
pregnant patients referred to abdomen and pelvis CT imaging.
B-0244 14:27
Size-specific dose estimates (SSDE) for the evaluation of individual
patient dose in CT protocol for renal colic
L. Waszczuk, M. Guziski, A. Czarnecka, J. Bladowska, M. S siadek;
Wroclaw/PL (
[email protected])
Purpose: To evaluate the effects of an institutional unenhanced CT protocol
for renal colic on image quality and radiation dose reduction using size-specific
dose estimates (SSDE).
Methods
and Materials: 52 consecutive patients with acute renal colic
underwent CT with reduced radiation dose (120 kVp; NI, 59.1; pitch, 0.984:1).
The evaluated radiation dose descriptors were SSDE (mGy), CTDI (mGy).
Signal-to-noise ratio (SNR), contrast-to-noise atio (CNR). Subjective image
assessment by two radiologists were performed. Visibility of abdominal, pelvic
parts of ureters, ureterovesical junctions and overall subjective image quality
were evaluated. The control group comprised 52 consecutive patients who
underwent routine CT on the same scanner.
Results
SNR of aorta, spleen, fat and psoas muscle were significantly smaller
in the renal colic group than the control (1.1 vs. 2.0; 1.8 vs. 3.0; 5.1 vs. 7.5; 2.0
vs. 3.1; respectively; p < 0.001). However, no statistically significant differences
in SNR of bladder and liver, and CNR of liver-spleen, liver-fat, aorta-muscle
and muscle-fat pairs were noted. Subjective image quality was better in the
control group (2.8 out of 3 possible points vs. 2.4). Differences in the visibility
of all 3 parts of ureters were not statistically significant (2.8 vs. 2.9; 2.2 vs. 2.4;
2.4 vs. 2.7). Significant radiation dose reduction in the renal colic group was
achieved (SSDE, 8 ±4 mGy vs. 22 ±8 mGy; CTDI, 7.5 ±4.8 mGy vs.
19.1±10.2 mGy, p < 0.001).
Conclusion
The institutional renal colic CT protocol provides a clinically good
image quality. Ureters' visibility and SNR/CNR values show that this protocol
should replace standard CT protocol.
B-0245 14:36
High correlation between CT radiation dose estimates obtained by fast
monte carlo computation and solid-state metal-oxide semiconductor
field-effect transistor measurements in physical anthropomorphic
phantoms
P. Prinsen
1, J. Wiegert1, S. Trattner2, R. Pieniazek2, T.L. Morton3, E. Gerland4,
C.M. Thompson5, S. Halliburton5, A.J. Einstein2; 1Eindhoven/NL, 2New York,
NY/US, 3Highland Heights, OH/US, 4Haifa/IL, 5Cleveland, OH/US
(
[email protected])
Purpose: Accurate, patient-specific estimati on of radiation dosimetry for CT
protocols is critical to optimise radiation doses and balance dose against image
quality. While MC simulation is often used to estimate doses from CT, few data
compare such estimates against experimentally measured doses in
contemporary CT scanners. We aimed to compare radiation dose estimates
from a MC approach to doses measured using MOSFETs in a 256-slice
volume scanner.
Methods
and Materials: 50 MOSFETs were placed inside a modified ATOM
(CIRS, Norfolk, VA) tissue-equivalent anthropomorphic phantom. The phantom
was then scanned using an iCT scanner (Philips, Cleveland, OH) with a chest
protocol (helical scan, 120 kVp, 360 mAs). MC computations were performed
on voxelised CT images of the phantom with a MC tool developed specifically
for diagnostic X-ray energies (DiPhoS, Philips Research, Eindhoven, The
Netherlands).
Results
In the directly irradiated section of the phantom the ratio of the
MOSFET measurements and the MC computations was 0.99 ±0.06 (30 data
points) and 0.97 ±0.03 (26 data points) for the female and male version of the
phantom, respectively. For comparison, the error bar on the individual ratios,
mainly composed of measurement uncertainties, was 0.06. In the region
receiving only scattered radiation dose ratios were also consistent with a value
of 1.
Conclusion
Radiation dose estimation using a MC method is strongly
correlated with experimental measurements. The availability of dose
distribution estimates based on actual reconstructed patient CT images may
offer the potential for accurate patient-specific CT dosimetry.
Author Disclosures:
S. Trattner: Research/Grant Support; Philips Healthcare. C.M. Thompson:
Research/Grant Support; Philips Healthcare. S. Halliburton: Research/Grant
Support; Philips Healthcare. Speaker; Philips Healthcare. A.J. Einstein:
Research/Grant Support; Philips Healthcare, GE Healthcare.
B-0246 14:45
Use of CT dose notification and alert values in routine clinical practice
C.H. McCollough, M. Howard, S. Leng, L. Yu, M. Bruesewitz, K. Grant;
Rochester, MN/US
Purpose: The purpose of this investigation was to assess the impact on
workflow of the use of notification and alert values in our practice and to
provide baseline data for quality improvement initiatives.
Methods
and Materials: Five diagnostic, clinical CT scanners were
programmed with the notification and alert values recommended by the
American Association of Physics in Medicine. Retrospective analysis was
performed on log files to assess the frequency of and reason for notification
and alert events.
Results
Between February and September of 2012, 11,384 patients were
scanned on the five systems. One alert occurred due to the use of bolus
tracking in a morbidly obese patient, where the pre-scan cumulative CTDI
vol for
the exam exceeded the recommended alert value of 1000 mGy. Only
1.2 ± 0.6% of patient scans triggered a notification. Notifications were mainly
triggered due to bolus tracking and/or la rge patient size. Protocols triggering
notifications most often included CT angiography of the chest for pulmonary
emboli.
Conclusion
Because only a small percentage of performed patient
examinations triggered a notification or alert event, the impact on workflow of
adopting these features was negligible. Evaluation of the logs identified trends
in reasons for which notification events were triggered; these primarily included
large patient size and bolus tracking. Additionally, specific protocols were
identified where adjustment of notification values was deemed necessary.
Author Disclosures:
C.H. McCollough: Grant Recipient; research support from Siemens
Healthcare, outside the submitted work.
B-0247 14:54
The assessment of effective dose and organ dose taking tube current
modulation into account
X. Lopez Rendon, H. Bosmans, R. Oyen, F. Zanca; Leuven/BE
(
[email protected])
Purpose: To evaluate the effect of including longitudinal tube current
modulation (TCM) versus using the average mAs on organ dose and effective
dose (E) calculations.
Methods
and Materials: 97 consecutive adult patients (46 female, 51 male)
underwent thorax/abdomen scans performed with TCM (CareDose 4D,
Siemens Definition Flash) at 120 kVp, 110 (thorax) and 200 (abdomen)
Reference
mAs. Body mass index (BMI) of all patients was registered. Doses to
fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were
calculated using two versions of CT-Expo: v.2.0, which uses the patient
average mAs and the new version 2.2, which includes an approximation of the
longitudinal modulation. Student t-test was used to asses statistical
significance.
Results
We found a significant difference (p < 0.001) for E, on both thorax
and abdomen CT exams, with E being overestimated on average by 3.3%
when no TCM is simulated. Also for organ doses a significant difference
(p < 0.001) was found with an average overestimation of 13.7% for the breast,
7.3% for the lungs, 9.1% for the liver and 8.5% for the stomach but an
underestimation of 11.5% for the ovaries when no TCM is used. No trend was
observed as a function of patient BMI for the difference between both methods.
Conclusion
The new version of CT-Expo that accounts for TCM showed
statistical significant differences in terms of E and organ doses when compared
S188
BA C D E F G
Thursday
to the previous version using only the average mAs. Future development could
use patient specific TCM profiles and pati ent size specific conversion factors.
B-0248 15:03
Efficacy of lens protection systems in cranial CT-scans: dependency on
different scanning techniques
N. Guberina, M. Schlamann, B. Mukherjee, A. Ringelstein;
Essen/DE (
[email protected])
Purpose: The purpose of this phantom study was to evaluate the potential
dose-attenuation of different eye lens protectors for patients undergoing
various cranial CT-scans at different scanners.
Methods
and Materials: Radiation exposure of the eye lens of seven common
CT-Algorithms at 2 different CT-scanners (SOMATOM® Definition AS (CT 1)
and SOMATOM® Definition Flash (CT 2) was measured with
thermoluminescence dosimeters (TLD-500, '-Al2O3:C) using two different lens
protectors (Somatex (SOM) and Medical-Imaging-Systems (MIS)).
Results
Dose attenuation accomplished by the different lens protectors is
summarised as follows: for CT 1 (a) unenhanced CT (nCT) with gantry
angulation: SOM (0%), MIS (0%); (b) CT-angiography (CTA): SOM (37%), MIS
(9%); (c) CT-perfusion (CTP): SOM (61%), MIS (64%); for CT 2 (d) nCT
without gantry angulation: SOM (19%), MIS (9%); (e) CTA Safire®: SOM
(61%), MIS (26%); (f) dual-energy-CTA without Safire®: SOM (31%), MIS
(7%); (g) CTP: SOM (56%), MIS (31%). Depending on the CT protocol but
independent from the scanner used, lens protector SOM attenuated the dose
up to 1.9 times more effectively compared to MIS. Physical analysis revealed
that the two lens protectors differ with respect to their density and thickness.
Conclusion
The efficacy of the two evaluated lens protectors differs widely
due to various material properties but is also highly dependent on the applied
CT-protocol. Lens protectors are most effective in CTA protocols when
reducing direct dose exposure. Considering both CT protocol and material of
the lens protectors is mandatory to reduce radiation exposure of the eye lens
of patients undergoing CT-scans.
B-0249 15:12
One-stop-shop myocardial 256-slice CT examination: what about the
cumulative radiation risk?
K. Perisinakis
1, I. Seimenis2, A. Tzedakis1, K. Pagonidis1, A. Papadakis1,
J. Damilakis1; 1Iraklion/GR, 2Alexandroupolis/GR
(
[email protected])
Purpose: To determine a) individual-specific estimates of radiation burden and
associated radiogenic cancer risks associated with myocardial 256-slice
coronary CT angiography (CCTA), dynamic CT perfusion (CTP) and delayed
enhancement CT (DECT) scans, and b) the total life attributable risk (LAR) of
radiation-induced cancer in individuals subjected to cardiac one-stop-shop
256-slice CT examination.
Methods
and Materials: The typical 256-slice CCTA, dynamic CTP and DECT
scans were simulated using Monte Carlo methods on sixty-two adult
individuals using an advanced simulati on software, dedicated for patient CT
dosimetry. Radiation absorbed doses were determined to primarily exposed
radiosensitive organs from each scan. Organ/tissue-specific radiogenic cancer
risk factors were used to derive indivi dual-specific LARs of cancer. The mean
total LAR from the CCTA+CTP+DECT scans' sequence was estimated and
compared to nominal intrinsic risk of cancer.
Results
The mean cumulative risk of radiogenic cancer associated with the
complete one-stop-shop cardiac 256-slice CT examination was found to
marginally increase the intrinsic risk for cancer induction by less than 0.6% in
females and less than 0.1% in males. The CTP scan was found to be the main
contributor to cumulative radiation burden from the 256-slice
CCTA+CTP+DECT scan-sequence. The 256-slice CTP+DECT scan
combination was found to be more dose-efficient compared to radionuclide
myocardial perfusion imaging.
Conclusion
The theoretical radiation cancer risks associated with the one-
stop-shop myocardial 256-slice CT examination may be considered low.
Nevertheless, every effort should be made towards acquisition protocol
optimisation for the dynamic CTP study which is the main contributor to patient
radiation burden.
14:00 - 15:30 Room N/O
Vascular
SS 215
Developments in CT imaging
Moderators:
M. Das; Maastricht/NL
K. Nikolaou; Munich/DE
B-0250 14:00
Foot perfusion CT in patients with peripheral arterial occlusive disease
treated with prostanoid drug: a pilot study
M. Nestola, R. Iezzi, M. la Torre, A. Contegiacomo, E. Antonuccio, L. Bonomo;
Rome/IT (
[email protected])
Purpose: To evaluate the effectiveness of treatment with prostanoid drug
(iloprost) in patients with PAOD using foot perfusion multidetector-row
computed tomography (MDCT) technique.
Methods
and Materials: After institutional review board approval and informed
patient consent were obtained, 10 patients with PAOD, older than 65 years,
were prospectively enrolled. All patients underwent dynamic foot 64-row-CT
examinations before and after daily iloprost infusion for one week, acquiring 8
contiguous 5-mm reconstructed sections, with 1-second gantry rotation time
and 60-second acquisition time, during injection of 40 mL of contrast medium
(Iomeprol 400 mgI/mL, @ 4 mL/sec). Data were analysed by two experienced
blinded readers using a dedicated software to calculate perfusion parameters,
such as blood flow (BF), blood volume (BV), mean transit time (MTT), and
permeability-surface area product (PS), before and after medical therapy.
Interobserver and intraobserver agreement of perfusion CT analysis were
assessed by Bland-Altman analyses. Perfusion parameters changes after
prostanoid therapy were assessed by Wilcoxon's test, compared to clinical and
laboratoristic evaluation.
Results
A good interobserver and intraobserver agreement of perfusion CT
analysis was obtained in all patients ( > 0.89). By comparing perfusion
parameters after prostanoid treatment, a significantly shorter MTT was
obtained, with good concordance with clinical results.
Conclusion
Foot CT perfusion, by providing the functional foot
microvasculature, could be an useful method to evaluate the effectiveness of
prostanoid therapy in patients with PAOD.
B-0251 14:09
Virtual monochromatic spectral image reconstruction in dual energy CT
angiography and its use to reduce iodine load
S. Suntharalingam, K. Nassenstein;
Essen/DE (
[email protected])
Purpose: To quantify the benefits concerning image quality of dual energy CT
angiography (DECTA) with virtual monochromatic spectral (VMS) image
reconstruction in comparison to standard CT angiography (CTA), and to test if
these benefits can be used to reduce iodine load.
Methods
and Materials: Ninety patients were randomised to three CT
protocols: CTA with injection of 100 ml contrast media with 350 mg/ml iodine,
DECTA with the same iodine load, and DECTA with reduced (75%) iodine
load. Nine series of VMS images were reconstructed (40-120keV). Signal
intensity (SI) and noise were measured in the aorta, musculature and fat, and
SNR and CNR values were calculated.
Results
Image reconstruction at 80 keV revealed best SNR and CNR values.
DECTA with 350 mg/ml iodine and image reconstruction at 80keV showed
higher SNR and CNR values compared to standard CTA (SNR aorta: 11.05 vs.
8.2; CNR aorta-fat: 16.8 vs. 11.9; p < 0.05). Image reconstruction of DECTA
with reduced iodine load at 80 keV showed higher SNR and CNR values
compared to CTA (SNR aorta: 12.7 vs. 8.2; CNR aorta-fat: 20.0 vs. 11.9;
p < 0.05), but significant lower SI values of the aorta (215.1 vs. 270.7). Image
reconstruction of DECTA with reduced iodine load at 70 keV showed similar SI
values of the aorta (272.3 vs. 270.7) but still higher SNR and CNR values
(SNR aorta: 11.4 vs. 8.2; CNR aorta-fat: 17.1 vs. 11.9; p < 0.05) compared to
CTA.
Conclusion
DECTA with VMS image reconstruction allow to improve CNR
and SNR, and to reduce iodine load compared to standard CTA.
S189
BA C D E F G
Thursday
B-0252 14:18
Flash-4D CT angiography in aortic dissection
C.-Y. Lu1, Y.-K. Diao1, Y.-Q. Guo1, X. Zhang2, Z.-L. Li1; 1Chengdu/CN,
2Shanghai/CN (
[email protected])
Purpose: To assess feasibility and diagnostic value of Flash-4D CT
angiography (CTA) for aortic dissection (AD).
Methods
and Materials: 18 consecutive patients with known or suspected AD
(age:30-76 years) referred for aortic CTA were scanned on a dual-source CT
scanner (Somatom Definition Flash, Siemens) using a high-pitch mode (pitch =
3.0) with an automatic selection of kilovoltage that proposes optimised kV and
mA settings according to planned examination type (Care KV; Siemens
Healthcare) for multiphasic image acquisition (range from the entrance of bony
thorax to the plane of symphysis pubis, time resolution 12s, 4 phases). CT
densities were measured in the aortic lumen and renal parenchyma.
Results
In all cases Flash-4D CTA can exactly display the true and false
lumen, intimal flap, the entry tear and the involvement of branches of AD.
Mean radiation dose was 11.6 ± 1.61 mSv. CT density of true lumen peaked at
407.6 ± 89.1 HU, signal-to-noise ratio was 17.2 ±7.83. Compared to standard
tri-phasic protocol (un-enhanced, arterial and portal scans), additional
diagnostic information was also obta ined as followed: enhancement delay
between true and false lumen (n=18); the degree of membrane oscillation
(n=16); perfusion delay in arteries originating from the false lumen (n=9) and
quantitative assessment of renal perfusion asymmetry (n=3).
Conclusion
Flash-4D CTA covering the entire aorta is feasible and can
exactly reveal pathological and anatomical features of AD with relative low
radiation dose. Compared to standard tri-phasic protocol, it can provide more
diagnostic information, which can be helpful for the selection of treatment
methods.
Author Disclosures:
X. Zhang: Employee; Siemens Shanghai Medical Equipment Ltd.
B-0253 14:27
Impact of the hybrid iterative reconstruction technique on image quality
of low-tube-voltage CT pulmonary angiography
A. Laqmani1, M. Regier1, S. Veldhoen2, A. Backhaus1, S. Sehner1, H.D. Nagel3,
G. Adam1, F.O. Henes1; 1Hamburg/DE, 2 Würzburg/DE,
3Buchholz/DE (
[email protected])
Purpose: To determine the impact of a hybrid iterative reconstruction (HIR)
technique (iDose, Philips Healthcare) on image noise and image quality in low-
tube-voltage and dose-reduced CT pulmonary angiography (CTPA) in
comparison to filtered back projection (FBP).
Methods
and Materials: 50 patients (mean body weight, < 80 kg) with
suspected pulmonary embolism (PE) underwent CTPA with 80 kV protocol
(Brilliance iCT; means: CTDIvol 2.3 mGy; DLP: 73.1 mGy*cm; effective dose:
1.2mSv). Raw data were reconstructed using FBP and three HIR levels (2, 4
and 6). Two radiologists assessed image quality and noise on a scale of 1
(poor) to 5 (excellent). Conspicuity of PE was assessed in central, segmental
and subsegmental arteries using a three-point scale (1, subtle; 2, sufficient; 3,
excellent). CT attenuation of pulmonary arteries, objective image noise (OIN)
and background signal was measured, contrast-to-noise ratios (CNR) were
calculated. Statistical analysis was performed using a random intercept model.
Results
With each HIR level, a significant decrease in subjective and
Objective
noise was achieved. In comparison with FBP, the lowest OIN was
achieved with HIR level 6 (means: 36.7 HU vs. 23.1 HU, respectively). CNR
significantly increased with application of HIR whilst CT attenuation in
pulmonary arteries maintained constant. Image quality was rated significantly
higher at HIR 2, 4 and 6 (means: 3.8, 4.7 and 4.7, respectively) compared to
FBP (mean: 3.3). Conspicuity of central and segmental PE improved with use
of HIR.
Conclusion
The HIR technique reduces image noise, improves image quality
and conspicuity of PE in 80 kV CTPA protocols.
B-0254 14:36
Acute limited dissection (class 3) of the aorta diagnosed with EKG-gated
CT angiography: a 10-year single center experience
A.S. Chin, A. Kino, G. Berry, D.C. Miller, D. Fleischmann; Stanford, CA/US
(
[email protected])
Purpose: Limited dissection (LD) is notoriously difficult to diagnose
prospectively, reported to elude all cross-sectional imaging techniques. ESC
Task Force classifies LD as "class 3" aor tic dissection, but this entity remains
largely unknown to radiologists. We have identified LDs at our institution on
ECG-gated CTA prospectively with surgical/pathologic confirmation. Our aim is
to evaluate the ability of state-of-the-art CTA to detect LD in the clinical setting
of acute aortic syndrome (AAS) and describe CTA imaging characteristics.
Methods
and Materials: CTAs from Jan 1, 2002 - Dec 31, 2012 in patients
presenting with AAS were retrospectively reviewed by two cardiovascular
radiologists. LD was diagnosed accor ding to ESC classification and
Svensson's 1999 original angiographic desc ription "subtle aortic contour bulge
without frank dissection flap." Additio nal post-processing was performed to
increase lesion conspicuity.
Results
Incidence of LD was 4.9% (25 LD, 291 classic dissection, 123 IMH,
29 penetrating atherosclerotic ulcer, 7 ia trogenic, 3 mycotic and 33 rupturing
aneurysm). Of 25 acute LDs, there were 17 type A and 8 type B (2 arch, 6
descending aorta). There was 100% surgical/pathological concordance with
pre-operative CTA diagnosis in 10/17 type A LDs who underwent urgent
surgery. One type B LD was "missed" on initial review.
Conclusion
Accurate detection of LD is possible using ECG-gated CTA,
although lesion awareness and meticulous dataset review is required;
additional post-processing increases lesion conspicuity. This is a first report of
prospective CTA diagnosis of LD, and the first to report type B LD using CTA.
B-0255 14:45
Feasibility study of CT-angiography with low kV settings and ultra low-
contrast medium volume in the assessment of thoracic and abdominal
aorta disease
C.R.G.L. Talei Franzesi, D. Ippolito, P.A. Bonaffini, D. Fior, O. Minutolo,
S. Sironi; Monza/IT (
[email protected])
Purpose: To assess the diagnostic quality and the radiation dose exposure of
low-kV CT angiography study (100 kV),by using ultra low-contrast medium
volume (40 mL), for thoracic and abdominal aorta evaluation.
Methods
and Materials: From July 2011 to march 2013, 81 patients (31
women; mean age 65.4 years; range, 35-83 years; BMI < 30),with thoracic or
abdominal aortic disease, were prospectively examined with 256-MDCT scan
(Brilliance iCT; Philips) using low-dose protocol (100 kV; automated tube
current modulation) and ultra low-contrast volume (40 mL; 4 mL/s;
350 mgI/mL). For the evaluation of ascending aorta, an ECG-gated
retrospective protocol was performed. A control group of 56 patients (20
women; mean age 67.2 years; range, 34-86 years) who underwent on the
same scanner standard CT-angiography protocol (120 kV; 350 mAs), with
standard contrast volume (100 mL) was also evaluated. Density
measurements were performed manually drawing a region of interest (ROI) on
lumen of ascending aorta, arch, descending and abdominal aorta, renal
arteries and common iliac arteries. The radiation dose exposure (dose-length
product, DLP) was also calculated for both groups. Then, the obtained data
were compared and statistically analysed.
Results
In all CT studies, we could correctly visualise and evaluate main
branches of thoracic and abdominal aorta. No significant difference of density
measurements was achieved between low-kV protocol (mean attenuation
value of thoracic aorta 310 HU, abdominal aorta 337 HU and renal arteries
329 HU) and the control group (mean value of thoracic aorta 316 HU,
abdominal aorta 331 HU and renal arteries 307 HU).The radiation dose
exposure was significantly lower (p < 0.05) in low-kV protocol (mean DLP
thoracic 490 mGy*cm; abdominal 335 mGy*cm) than in control group (mean
DLP thoracic 625 mGy*cm; abdominal 952 mGy*cm), with an overall reduction
of 22% in the thoracic and 65% for abdominal study.
Conclusion
Low-kV protocol provides a diagnostic performance comparable
to standard protocol, decreasing significantly the radiation dose exposure as
well as the contrast material volume, reducing also the risk of contrast-induced
nephropathy.
B-0257 14:54
CTA imaging characteristics of rupturing thoracic aortic aneurysm in
acute aortic syndrome: a 10-year single center experience
A.S. Chin, A. Kino, D. Fleischmann; Stanford, CA/US
(
[email protected])
Purpose: The incidence of leaking or rupturing thoracic aortic aneurysm is
largely unknown as many succumb before coming to medical attention. Our
aim is to evaluate the incidence of leaking/rupturing aortic aneurysm
presenting as acute aortic syndrome (AAS) and describe CTA imaging
characteristics.
Methods
and Materials: CTAs from Jan 1, 2003 - Dec 31, 2012 in patients
with AAS were retrospectively reviewed by two cardiovascular radiologists.
Leaking/rupturing aneurysm was diagnosed based on aortic diameter greater
than 40 mm AND (1) contrast extravasation, (2) pseudoaneurysm formation, or
(3) other imaging finding indicating acute aortic injury including periaortic
hematoma, intramural hematoma or mediastinal hemorrhage.
Results
511 patients were diagnosed with AAS with 6.5% incidence of
rupturing thoracic aneurysm (291 classic dissection, 123 IMH, 25 limited
dissection, 29 penetrating atherosclerotic ulcer, 7 iatrogenic, 3 mycotic and 33
rupturing aneurysm). There was 87.9% (29/33) descending involvement. 20/33
patients underwent surgical or endovascular treatment with 15% in-hospital
mortality versus 38.5% in-hospital mortality with conservative management.
Conclusion
Leaking or rupturing thoracic aneurysm represents a significant
portion of patients presenting with AAS, comparable to penetrating
atherosclerotic ulcer in our series, an d most frequently involves the descending
aorta.
S190
BA C D E F G
Thursday
B-0258 15:03
Low-dose 256-MDCT angiography of the carotid arteries: effect of hybrid
iterative reconstruction technique on noise, artefacts, and image quality
E. Kondratyev, G.G. Karmazanovsky, V. Shirokov, N. Tarbaeva,
A. Vishnevskaia; Moscow/RU (
[email protected])
Purpose: To evaluate the effect of hybrid iterative reconstruction on qualitative
and quantitative parameters at low-dose carotid CTA
Methods
and Materials: 44 consecutive patients were enrolled in the study.
First group (n=22) was examined under 120 kV 250 mAs and second group
(n=22) under 100 kV 250 mAs. CT images in first group were reconstructed
only with the filtered back projection (FBP). CT data in second group were
reconstructed both with FBP and three levels of hybrid iterative reconstruction
algorithm (iDose). We compared quantitative and qualitative parameters
among the two groups and among four different reconstructions in second
group.
Results
Effective dose in 120 kV and 100 kV group was 7.18 ±1.19 mSv and
4.14±1.03 mSv, respectively (p < 0.0001). Mean arterial attenuation was about
25% higher in second group (236.5 ±46 vs. 302.6±32.7 HU; p < 0.0001). Image
noise at the level of humeral belt was 32.5 ±12.5 in 100 kV group and
26.3±13.3 in 120 kV (p=0.115. Average noise decreased when using 3 levels
of iDose up to 23.6 ±6.4, 17.7± 5.6, 13.7 ±5.1, respectively (p=0.00001). Mean
CNR increased to 10.38 ±3.87, 14.5 ±5.21, 18.32± 8.61, respectively (p < 0.05).
The presence of artifacts on the level of humeral belt in 120 kV group was
14%, in 100 kV - 41% (p=0.002). The difference in visual scores between
standard and low-dose protocol was significant (p=0.008). When applying
iterative reconstruction, the frequency of streak artifacts decreased
dramatically (p < 0.0001). Most studies had excellent quality with no artefacts
while using highest level of iDose.
Conclusion
Low-dose MDCT angiography using hybrid iterative
reconstruction may provide sufficient image quality and allows for significant
reduction of patient dose.
B-0259 15:12
Comparison between CT venography at 320 multi-detector row scanners
with conventional angiography in patients with failed arteriovenous axis
for haemodyalysis
Y. Ragab
1, H. Hamza2, A. El Marakby1, F. Zeinhohm1; 1Cairo/EG,
2Doncaster/UK (
[email protected])
Purpose: To compare CT venography at 320 multi-detector row scanners with
conventional angiography in patients with failed arteriovenous axis for
haemodyalysis.
Methods
and Materials: retrospective study including 50 ptients with failed
arteriovenous axis for haemodyalysis (37 men, 13 women) who underwent 320
multi-detector CT venography of the thoracic inlet prior to angioplasty. Findings
on CT angiograms, including CT scans, maximum intensity projections, and
three-dimensional volume-rendered images, were used to evaluate the site
and cause of axis failure.
Results
Among the 50 patients initially treated with venous angioplasty, 56
venous occlusions were identified. In 94% of cases, concordant findings were
observed with both modalities (CTV and conventional venography). In five
(6%)cases, CT could not be used to identify precisely the site of venous
obstructions. In 5% cases, CT depicted venous tight stenoses that could not be
tackled by angioplasty. Three-dimensional images were found to be superior to
2D CT angiogrphic in depicting the anatomical venous anomalies which
enabled the interventional radiologist s to perform successful angioplasty after
direct catherization.
Conclusion
CT venography using 320 multi-detector systems provides more
accurate depiction of the venous anatomy of the thoracic inlet prior to
conventional venography and angioplasty.
14:00 - 15:30 Conf. Room M3
Interventional Radiology
SS 209
MR-guided high-intensity focused
ultrasound
Moderators:
N. Grenier; Bordeaux/FR
C.M. Sommer; Heidelberg/DE
B-0260 14:00
Reintervention rate and symptom improvement following volumetric MR-
guided high-intensity focused ultrasound versus uterine artery
embolisation for uterine fibroids: a multicenter study
M.E. Ikink1, R.J. Nijenhuis1, H.M. Verkooijen1, P.N.M. Lohle2,
M.A.A.J. van den Bosch1; 1Utrecht/NL, 2Tilburg/NL (
[email protected])
Purpose: To assess the effectiveness of MR-guided High-Intensity Focused
Ultrasound (MR-HIFU) for treatment of uterine fibroids in comparison to Uterine
Artery Embolisation (UAE).
Methods
and Materials: Between January-2011 and January-2013, 51
women with symptomatic fibroids underwent MR-HIFU in the UMC Utrecht.
Clinical and imaging data were compared to 68 women treated with UAE in the
St.Elisabeth Hospital Tilburg, those who would theoretically been eligible for
MR-HIFU based on fibroid size ( 12 cm) and number ( 5), absence of
interposed intestines and other pelvic diseases. We compared reintervention
within 12-months following treatment; symptom severity (tSSS) and quality of
life (HRQoL) scores 3-months after initial treatment. Logistic regression was
performed to calculate the adjusted Odds-ratio of clinically relevant symptom
improvement (defined as 3-months tSSS 20) of women treated with MR-HIFU
versus UAE. Cox regression was applied to calculate the adjusted risk of
reintervention between both groups.
Results
After MR-HIFU, the median tSSS improved from 53.1 (IQR
[40.6.68.8]) at baseline to 34.4 (IQR [21.9.46.9]) after 3-months (p < 0.001).
After UAE, median tSSS improved from 65.3 (IQR [56.3.74.2]) to 21.9 (IQR
[9.4.34.4]; p < 0.001). For both groups, HRQoL improved significantly from
baseline to follow-up (p < 0.001). Compared to UAE, women treated with MR-
HIFU were less likely to develop adequate symptom improvement (OR=0.07;
95%-CI [0.02.0.29]; p < 0001). At 12-months, patients treated with MR-HIFU
had a 7.11 (95%-CI [2.00.25.3]; p=0.002) times higher risk of reintervention.
Conclusion
Women with symptomatic uterine fibroids had a higher probability
of adequate symptom improvement and a lower risk of reintervention if treated
with UAE as compared to MR-HIFU.
B-0261 14:09
New fronteers for the multiple uterine fibroids therapy: combined
treatment using MRgFUS and uterine artery embolisation
F. Ferrari, A. Miccoli, F. Arrigoni, S. Carducci, A. Giordano, G. Mascaretti,
C. Masciocchi; L'Aquila/IT (
[email protected])
Purpose: To evaluate the combination between magnetic resonance-guided
focused ultrasound (MRgFUS) and uterine artery embolisation (UAE) to
increase the number of patients, affected by multiple uterine fibroids, treatable
by non-surgical therapy.
Methods
and Materials: From December 2012 to September 2013, 6 patients
with multiple uterine fibroids, aged between 36 and 51, were first treated by
MRgFUS and after 1 month using UAE. Each patient presented more than 3
fibroids, measuring between 3 and 14 cm. Four patients had 4 fibroids, 1 of
these was treated using MRgFUS and the others with UAE. Two patients
presented 3 fibroids, 2 treated by MRgFUS and the others using UAE. The use
of UAE after MRgFUS caused an increase of the necrotic area in fibroids
already treated, improving the treatment efficacy, and allowing the treatment of
fibroids otherwise untreatable by MRgFUS. Each patient was subjected to
clinical evaluation using the severity-score-questionnaire.
Results
We obtained a good response in both treatments, without any
complication. The "non perfused volume" showed a mean value of 86.5% in
fibroids treated with MRgFUS, and a mean value of 90% for fibroids treated
with UAE. The symptomatic score showed a reduction of about 90%, if
compared to the pre-treatment score.
Conclusion
These combined treatments imply minimal hospitalisation and
complications preserving uterus integrity when the invasive surgery would be
the only therapeutic possibility.
S191
BA C D E F G
Thursday
B-0262 14:18
Osteoid osteoma: magnetic resonance-guided high intensity-focused
ultrasound for entirely non-invasive treatment: a prospective
developmental study
A. Napoli, M. Anzidei, F. Boni, L. Bertaccini, G. Brachetti, C. Catalano;
Rome/IT (
[email protected])
Purpose: To determine the efficacy of MR-guided focused ultrasound
(MRgFUS) treatment of symptomatic osteoid osteomas.
Methods
and Materials: This prospective, IRB approved study involved 15
consecutive patients (11 m, 4 f, mean age 21) with clinical and imaging
diagnosis of osteoid osteoma, all patients underwent MRgFUS ablation
(ExAblate, InSightec). Lesions located in the vertebral body were excluded,
while lesions in proximity to joints or neurovascular bundles were included.
Treatment success was determined at clinical and imaging follow-up at 1, 6
and 12 months post-treatment. A visual analogue pain score was used to
assess changes in symptoms. Bone changes at nidus site were evaluated on
the basis of CT and dynamic ce-MR imaging (Gd-Bopta; Bracco) pre- and post-
treatment.
Results
Treatment was carried out using a variable sonications number
(4±1.8) with a mean energy deposition of 866 ±211 J. There were no treatment
or anesthesia-related complications. A sta tistically significant difference
(p=0.001) was noted between pre- and post-treatment VAS scores (8.3 ±1.6 vs
0.6±1.5, respectively). Two treatments were conducted in patients with prior
CTgRFA failure and needed two different sessions to achieve complete clinical
success. At imaging, edema and hyperemia gradually disappeared in all
lesions. No apparent relationship between nidus vascular extinction and
successful outcome was found. Variable reabsorption degree of sclerotic
reaction was observed with nidus disappearance in 4 cases (27%).
Conclusion
Treatment of osteoid osteoma using MRgFUS can be performed
safely with high rate of success and without treatment-related morbidity. Our
Results
also indicated a positive trend to bone rearrangement after treatment.
B-0263 14:27
Our experience of non-invasive treatment of epiphyseal benign bone
lesions using MRgFUS: can it really be a definitive solution?
F. Arrigoni, L. Gregori, A. La Marra, A. Conchiglia, L. Zugaro, A. Barile,
C. Masciocchi; L'Aquila/IT (
[email protected])
Purpose: To evaluate the role of MRI-guided focused ultrasound (MRgFUS) in
the treatment of epiphyseal benign bone lesions in which the surgery would be
too demolitive.
Methods
and Materials: From March 2011 to August 2013 we treated 12
epiphyseal benign bone lesions: seven fibro-osteitis (four of the humerus; two
of the foot; one of the knee), two periosteal chondroma of the femoral neck,
two fibromixomas of the knee and one osteoblastoma of the femoral neck. All
patients were studied by CT and MRI and evaluated by VAS scale, for the
clinical symptoms before and after (6 and 12 months) treatment. The nature of
all the lesions was confirmed by biopsy.
Results
After the treatment all patients, except one, showed regression in
painful symptomatology with mean VAS that decreased from 7.8 to 2.5. In the
patient with periosteal chondroma of the femoral neck no improvement in
symptomatology was observed. At the MRI and CT evaluation after treatment,
in no case a progression of disease was described. No substantial changes
were found in the CT images of controls. Instead, in the MRI evaluations, in all
the lesions, there was the reduction of bone edema around the lesion already
to the first control at 6 months. In no case major complications were observed.
Conclusion
Though further and larger studies are needed our experience
shows that the use of MRgFUS is a safe and effective treatment for those
lesions in which the surgery would be too invasive in relation with the grade of
lesions.
B-0264 14:36
Magnetic resonance-guided focused ultrasound surgery (MRgFUS)
treatment of painful bone metastases: can ADC value predict the clinical
outcome?
F. Boni, F. Zaccagna, A. Napoli, V. Noce, L. Bertaccini, C. Catalano; Rome/IT
(
[email protected])
Purpose: To evaluate the role of ADC values in the assessment of bone
metastasis' response after MR-guided focused ultrasound surgery (MRgFUS),
and to correlate these modifications with clinical outcomes.
Methods
and Materials: 23 patients with bone metastases underwent
MRgFUS treatment (ExAblate2100,InSightec). Lesion's size and locations
were determined using CT and MRI; all MRI scans were performed with a 3 T
unit paired with the ExAblate system. Treatments were performed under
general anaesthesia or subarachnoid spinal block. Follow-up examinations
were performed 1, 3 and 6 months after treatment; pain severity and pain
interference were evaluated using a Visual Analogue Scale, meanwhile
imaging assessment was performed by comparing pre- and post-treatment
ADC values.
Results
All patients well tolerated the treatment and no heating-related
adverse events were recorded. The VAS score decreased from baseline
7.09±1.8, to 2.65±1.36 at first follow-up and 1.04 ±1.91 at third month follow-up;
at sixth month, it was stable (1.09 ±1.99). ADC values increased of +48.9% at
first month follow-up (p < 0.001), and it was stable in the following
examinations (43.3% at 3 months and 42.8% at 6 months). Moreover, there
was a statistically significant negative correlation between ADC and VAS ( ;=-
0.684; p=0.03).
Conclusion
Preliminary data showed that an increment in ADC values is
strongly associated with pain relief after MRgFUS treatment in patients with
bone metastases; moreover, we also demonstrated a different percentage of
increase in ADC values according to response assessment. Therefore, in
conclusion, ADC value could play an important role in outcome prediction in
patients undergoing MRgFUS for painful bone metastasis.
B-0265 14:45
Primary pain palliation and local tumour control in bone metastases
treated with MR-guided focused ultrasound
F. Zaccagna, B. Cavallo Marincola, A. Napoli, F. Boni, G. Brachetti,
L. Bertaccini, C. Catalano; Rome/IT (
[email protected])
Purpose: To evaluate the clinical performance of MRgFUS in the primary
treatment of painful bone metastases and to explore the potential of this
technique in achieving local control.
Methods
and Materials: 26 consecutive patients (female/male 12/14; age:
64.7±7.5) with painful bone metastases were enrolled in this study. Before and
3 months after MRgFUS treatment, pain severity and pain interference scores
were assessed according to Brief Pain Inventory-Quality of Life (BPI-QoL)
criteria and patients underwent both CT and MRI. Local tumour control was
evaluated according to lesion size, density and perfusion at CT, dynamic
contrast enhancement at MRI (Discovery 750HD, GE; Gd-Bopta, Bracco) and
metabolic activity at PET or scintigraphy. Patients were classified into
responders and non-responders.
Results
No treatment-related adverse events were recorded during the study.
A statistically significant difference bet ween baseline and follow-up values for
both pain severity and pain interference scores was observed (p < 0.05).
Increased bone density was observed in 9/26 (34.6%) patients. Non-perfused
volume values ranged between 20% and 92%. There was no difference in NPV
values between responders and non-responders (46.7 ±24.2% [25 - 90 %] vs.
45±24.9% [20 - 93 %]; p=0.7). In 6 patients (5 prostate and 1 breast primary
cancer), there was nearly absence of metabolic activity after treatment (mean
SUV=1.2).
Conclusion
MRgFUS can be safely and effectively used as the primary
treatment for pain palliation in patients with bone metastases; our experience
demonstrated also a potential role for the MRgFUS in local tumour control as
confirmed by metabolic analysis.
B-0266 14:54
Magnetic resonance-guided focused ultrasound surgery (MRgFUS)
treatment of primary pancreatic and hepatic cancer: preliminary
experience in tumour control
F. Zaccagna, F. Boni, L. Bertaccini, V. Noce, M. Anzidei, A. Napoli,
C. Catalano; Rome/IT (
[email protected])
Purpose: Hepatic tumours (HCC) and pancreatic cancer represent two of the
most challenging abdominal tumours due to their vascular relationship and to
the poor prognosis. Both these cancers have been successfully treated with
focused ultrasound under conventional US guidance. Magnetic resonance-
guided focused ultrasound surgery (MRgFUS) introduces the advantage of
real-time monitoring, allowing a more precise lesion's ablation and a more
accurate in-treatment patient management. This technique has been widely
used in other applications while its use to treat HCC and pancreatic cancer is
still in its preliminary phase. Therefore, our purpose was to evaluate safety and
effectiveness of high-intensity MR-gui ded focused ultrasound treatment in
pancreatic and HCC.
Methods
and Materials: 5 patients with pancreatic cancer and 1 with
unresectable right lobe HCC underwent MRgFUS treatment (ExAblate2100,
InSightec). Treatments were done in a single ambulatory session. To evaluate
tumour control, perfusion T1w images after contrast medium administration
were obtained pre- and post-treatment. Follow-up examinations were
scheduled at 1, 3, 6 and 12 months.
Results
All patients well tolerated the treatment and no heating-related
adverse event was recorded. Immediately after treatment, all patients showed
coagulative necrosis with a mean non-perfused volume of 65.4 ±16.6 [45 - 90].
All patients with pancreatic cancer showed a significant decrease of pain. At
follow-up, no local progression was recorded; after MRgFUS 2 patients with
pancreatic cancer underwent RT meanwhile another one required a second
MRgFUS treatment.
S192
BA C D E F G
Thursday
Conclusion
Our preliminary experience indicates that MRgFUS could be a
promising non-invasive treatment modality in patients with unresectable
pancreatic cancer and HCC.
B-0267 15:03
Role of magnetic resonance-guided high intensity focused ultrasound
(MRgFUS) surgery as non-invasive treatment of breast cancer in patients
with focal disease
A. Napoli, V. Noce, L. Di Mare, M. Anzidei, F. Pediconi, L. Bertaccini,
C. Catalano; Rome/IT
Purpose: To assess safety and feasibility of 3 T MR-guided focused
ultrasound (MRgFUS) ablation of invasive ductal breast cancer (stage T1 M0
N0) prior to surgical resection and sent inel lymph node biopsy. As secondary
outcome, we evaluated MRI accuracy in the assessment of residual disease.
Methods
and Materials: Eleven patients with unifocal biopsy-proven IDC,
scheduled for lumpectomy and sentinel lymph node biopsy, underwent
MRgFUS treatment. Pre-treatment imaging was performed on a 3 T MRI unit to
localise the enhancing lump and to evaluate treatment's feasibility according to
its size ( < 2 cm) and location. All patients underwent MRgFUS treatment
(ExAblate 2100; InSightec) in a day-surgery setting. Immediately after the
treatment, a contrast-enhanced MRI (CE-MRI) was performed to evaluate
treatment response; post-surgery pathological evaluation was considered as
Reference
standard to assess treatment's efficacy.
Results
All patients well tolerated the treatment and no heating-related
adverse event was recorded. At post-treatment CE-MRI, no enhancing lesion
was seen in 9 patients; in these patients, post-surgery pathological evaluation
demonstrated an area of necrosis with 5-mm margins of normal breast tissue
and no foci of residual disease. In the remaining 2 cases, treatment was
interrupted due to a transducer's malfunction; CE-MRI demonstrated a fainting
enhancement and post-surgery pathological evaluation showed a 15% of
residual tumour in the ablated area. Post-treatment CE-MRI assessment of
residual tumour was strongly correlated to post-surgery pathological evaluation
of treatment response.
Conclusion
MRgFUS is an innovative and totally non-invasive treatment
modality for unifocal breast cancer that allows a safety and efficacy treatment
due to MR guidance.
B-0268 15:12
Non-invasive focal therapy of organ confined prostate cancer: phase-I
study using magnetic resonance guided focused ultrasound technology
and excision pathology for efficacy assessment
D. Pier Luigi, A. Napoli, F. Zaccagna, G. Cartocci, F. Boni, V. Noce, V. Noce,
C. Catalano; Rome/IT (
[email protected])
Purpose: To assess safety and effectiveness of non-invasive MR-guided
focused Ultrasound Surgery (MRgFUS) treatment of localised prostate cancer
in a phase-I, treat and resection designed exploratory study.
Methods
and Materials: 11 patients with biopsy proven focal T2 prostate
cancer (low-to-intermediate risk: PSA < 12 and Gleason < 3+4), confirmed on a
previous multiparametric MRI including dynamic contrast enhanced (DCE)
imaging (Gd-BOPTA, Bracco), underwent MRgFUS ablation (ExAblate,
InSightec). All patients were scheduled to radical laparoscopic prostatectomy.
MRgFUS treatment was carried out on the MR identifiable lesion ( < 2) using a
patient specific energy (3000-8500 J) and real- time MR thermometry. Non-
perfused volume (NPV) in the post-treatment MRI was compared with excision
pathology for necrosis assessment.
Results
No significant complications were observed in all subjects during or
immediately after the procedure. Treatment was validated by pathological
examinations, which demonstrated extensive coagulative necrosis at the site of
sonication surrounded by normal pros tatic tissue with inflammatory changes;
these features were positively correlated with the immediate post-treatment
MRI scan and NPV values. At histology, 10 patients were free of residual
viable tumour within the treated area; in the remaining patient, 10% of residual
tumour was observed within the NPV. There was a variable amount of isolated
cancer tissue (Gleason< 6, 3+3) within non-treated parenchyma that was
neither identifiable at MRI nor at biopsy.
Conclusion
Results of our Phase-I study suggest that MRgFUS is a safe and
effective modality to determine a > 90% necrosis of identifiable prostate
cancer; other prospective studies are needed to extend success rate in larger
cohort.
B-0269
15:21
Image-guided high-focused ultrasound for renal sympathicolysis: a
feasibility study in pigs
P. Freyhardt, L. Heckmann, A. Beck, N. Stolzenburg, J. Schnorr,
J.-L. Rinnethal, R.W. Günther, F. Streitparth;
Berlin/DE (
[email protected])
Purpose: To evaluate feasibility, safety and efficacy of MR-guided high-
focused ultrasound (MRgHiFUS) for renal sympathetic denervation in pigs.
Methods
and Materials: Renal periarterial MRgHiFUS was performed under
general anaesthesia in 10 pigs (unilaterally in 9 pigs, sham treatment in 1 pig).
Blood pressure measurements and MRI of the kidneys, renal arteries and
surrounding structures were acquired immediately pre- and post-intervention
and after 4 weeks. Hereafter, all animals were killed to histologically examine
induced neural degeneration and to assess efficacy of the procedure by
determining norepinephrine (NE) concentration in the renal parenchyma.
Results
On average, 10.5 ±2.9 sonifications with a mean energy of 2671 ±446
Joule were applied. Post-interventional MRI revealed a periarterial oedema on
the treated side in three pigs, corresponding histologic changes were found in
one pig. Renal NE was lower (-8 to -27 %) on the treated side than on the
untreated side in 5 of 7 unilaterally treate d pigs. A significant difference in the
average NE level between the treated (392 ng/g) and untreated kidneys
(430 ng/g) of all unilaterally treated animals was not found. Post-interventional
MRI indicated that special anatomic features led to ultrasound energy
absorption at the transverse process and fascia.
Conclusion
MRgHiFUS did not induce significant renal sympathicolysis in a
pig model, probably due to insufficient pe riarterial energy deposition. Since a
HiFUS treatment in humans is expected to be easier to perform due to a better
access to renal sympathetic nerve fibres, further studies of this method are
desirable.
14:00 - 15:30 Board Room A
Radiographers
SS 214
Quality improvement in screening and
symptomatic mammography services
Moderators:
C. Mandel; East Melbourne/AU
D. O'Leary; Dublin/IE
B-0270 14:00
Mammographic positioning quality of newly trained vs experienced
radiographers in the Dutch breast cancer screening programme
C.G.C.M. van Landsveld-Verhoeven, J.M.H. Timmers, M.J.M. Broeders,
G.J. den Heeten; Nijmegen/NL (
[email protected])
Purpose: To compare mammographic positioning quality of new (NR) versus
experienced screening radiographers (ER).
Methods
and Materials: Radiographers must complete an initial education
course before starting to work in the Dutch breast screening programme. This
course consists of a theoretical part (4 days) and a practical training period (6
weeks). A portfolio of 50 mammograms, randomly selected from screening
practice, is part of the examination. Audits are part of the quality assurance
programme and a review of positioning quality of screening mammograms is
one of the activities performed. We analysed 7079 views from portfolios and
14896 audit views. All mammograms were reviewed based on pre specified
criteria, e.g. depiction of the inframammary angle and nipple in profile.
Results
Positioning was more adequate for NR than ER (CC views: 96.5%
versus 86.4%, p=0.00; MLO views: 91.9% versus 84.5%, p=0.00).
Mammograms from ER were more often poor, because the errors were more
severe. For the CC views, the NR scored better for most of the criteria: they
had less problems with bucky height (5.6% versus 9.2%, p=0.00) and less
lateral and medial folds compared to ER (10.4% versus 15.6%, p=0.00). On
the contrary, for MLO views, NR encountered more difficulties, especially with
the symmetry (12.0% versus 5.7%, p=0.00) and depiction of the inframammary
angle without folds (68.3% versus 58.8%, p=0.00).
Conclusion
Overall, NR perform better than ER. These results stress the
need for continuous auditing and training in breast cancer screening
programmes to keep positioning skills up to date.
Author Disclosures:
G.J. den Heeten: Founder; Co-founder of Sigmascreening a spin off company
of the Academic Medical Centre Amsterdam.
S193
BA C D E F G
Thursday
B-0271 14:09
Reject analysis for digital mammography (2D) including 2D plus
tomosynthesis in high volume mammography screening
R. Hammond1, R. Gullien1, B. Østerås1, I. Hauge2; 1Oslo/NO, 2Østerås/NO
(
[email protected])
Purpose: Reject rates and reasons for rejected images between digital
mammography (2D) compared with 2D plus tomosynthesis in high volume
mammography screening.
Methods
and Materials: Reject analysis for an 18 month period included a
total of 95,976 mammography images, 22,772 from 2D examinations and
73,204 from 2D plus tomosynthesis. For 2D plus tomosynthesis, one image is
defined as both 2D and a tomosynthesis acquisition. Rejection rate was
calculated on per image basis, presented with 95% Confidence Intervals (CI)
estimated using the Wilson score method. Rejected images were assigned into
categories for reasons: 1) positioning, 2) x-ray equipment failure, 3) patient
motion, 4) artifacts and 5) others
Results
Total rejection rate for 2D was1.62% [CI: 1.46-1.79] (368/22772) and
2D plus tomosynthesis1.28% [CI: 1.20 - 1.37] (939/73204). Stratified rejection
rate for categories: 1)positioning: 0.82% [CI: 0.71 - 0.95] vs. 0.69% [CI: 0.63 -
0.75]; 2)x-ray equipment failure: 0.60% [CI: 0.51 - 0.71] vs. 0.37% [CI: 0.33 -
0.42]; 3)patient motion: 0.066% [CI: 0.040 - 0.11] vs. 0.089% [CI: 0.070 - 0.11];
4)artifacts: 0.022% [CI: 0.0094 - 0.051] vs. 0.041% [CI:0.029 - 0.058]; 5)others:
0.11% [CI: 0.071 - 0.16] vs. 0.092 % [CI: 0.072 - 0.12] for 2D and 2D plus
tomosynthesis, respectively. Overall rejection rate was significantly higher for
2D compared with 2D plus tomosynthesis. Most common reasons for rejections
were: Positioning and X-ray equipment failure.
Conclusion
Positioning is the most common reason for rejections.
Tomosynthesis may be implemented in a high volume breast cancer-screening
program without an increase in rejected images.
Author Disclosures:
R. Hammond: Advisory Board; Hologic, Inc. 2012. Other; Travel costs 2012,
Hologic, Inc. R. Gullien: Other; Travel costs 2012, Hologic, Inc.
B-0272 14:18
Tomosynthesis in mammography screening: invited women's attitude
regarding radiation health effects and pain experience
R. Gullien, R. Hammond, J. Andersen, P. Skaane; Oslo/NO
(
[email protected])
Purpose: Comparing participants and non-participants responses when
offered tomosynthesis in addition to 2D mammograms based on informed
consent in a screening program.
Methods
and Materials: From Sept.28 th to Dec.12 th 2012, 4609 women aged
50-69 attended a population-based screening program. 2922 women voluntary
answered a questionnaire including questions about concern of radiation
health effects and pain experience. Both participants and non-participants were
asked to reply. Most questions were identical for both groups. 34 incomplete
questionnaires were excluded.
Results
82% (2367/2888) of participants and 18% (521/2888) of non-
participants replied. There was no difference regarding level of education, self-
assessment of knowledge of radiation, and previously history of mammography
between the groups. 780 (33%) of participating and 133 (26%) of non-
participating women had heard about tomosynthesis (p < 0.05). Of all repliers,
93.5% (2700/2888) were not/slightly concerned about radiation health effects.
Among participants, 96% (2254/2367) were not/slightly concerned about
radiation effects compared with 86% (446/521) among non-participants
(p < 0.05). 75% (2178/2888) of all repliers experienced no/little pain during the
examination, 77% (1821/2367) vs. 68% (357/521) for participants and non-
participants, respectively. Of wom en receiving tomosynthesis, 75%
(1785/2367) experienced no difference, 6% less, and 8% more pain compared
with previous mammography. 91% (2148/2367) felt the examination-time was
the same, and 91% (2144/2367) believed to have received a better
examination.
Conclusion
The majorities of women choosing tomosynthesis had a low level
of anxiety for adverse radiation health effects and believed they received a
better examination. They didn't find tomosynthesis more painful or longer than
a standard 2D mammogram.
Author Disclosures:
R. Gullien: Other; Travel costs and fees for one lecture in 2012, Hologic,
Inc. R. Hammond: Advisory Board; Hologic, Inc. 2012. Other; Travel costs and
fees in 2012 by Hologic, Inc. P. Skaane: Equipment Support Recipient;
Hologic, Inc. Research/Grant Support; Financial support when overtime
reading was necessary by Hologic, Inc.
B-0273 14:27
Reject analysis in high-volume mammography screening: comparison of
image quality between rejected and replaced images
R. Hammond, R. Gullien, J. Andersen, P. Skaane; Oslo/NO
(
[email protected])
Purpose: Compare image quality of retained images from multiple sets of
rejected and repeated images using the classification system PGMI (Perfect,
Good, Moderate, Inadequate).
Methods
and Materials: From October 2011-December 2012, a total of 544
images were rejected by radiographers with the reason "positioning". 18
images were excluded due to incomplete information. All rejected and repeated
paired images were given a PGMI score separately by an PGMI-radiographer.
PGMI score for each image set was compared and placed into one of three
categories, depending on the score of the retained image: Higher (H), Same
(S) or Lower (L) PGMI score. For category S and L, further analysis were done
on reasons for repeating an image.
Results
67% (351/526) of the repeated had a higher PGMI score than the
rejected images; 30% (159/526) had the same PGMI score; 3% (16/526) had a
lower PGMI score. For category "S" rejected images: 9% (15/159) were CC
and 91% (144/159) were MLO images. Category "L": 13% (2/16) of rejected
images were CC and 87% (14/16) were MLO. Of the rejected images within
categories "S" and "L", a total of 90% (158/175) were MLO. They were rejected
for the reasons: a) pectoral muscle not to the nipple level 35% (56/158), b)
folds in the inframammary fold 19% (30/158), c) nipple not in profile 13%
(21/158), d) inframammary fold not visible 9% (15/158), e) others 3% (23/158).
Conclusion
Two thirds of the repeated images show improved image quality,
but there is potential for improvement of rejected images.
Author Disclosures:
R. Hammond: Advisory Board; Hologic, Inc. 2012. Other; Travel costs and
fees in 2012, Hologic, Inc. R. Gullien: Other; Travel costs and fees for one
lecture in 2012, Hologic, Inc. P. Skaane: Equipment Support Recipient;
Hologic, Inc. Research/Grant Support; Financial support when overtime
reading was necessary by Hologic, Inc.
B-0274 14:36
Failure on clinical image quality criteria in digital mammography: how
can radiographers do better?
C.S.D. Reis1, M.F. Oliveira2, A. Pascoal3, A. Pascoal3, J. Alves2; 1Lisbon/PT,
2Sacavém/PT, 3London/UK (
[email protected])
Purpose: To assess image quality using PGMI (perfect, good, moderate,
inadequate) scale in digital mammography examinations acquired in DR
systems. Identify the main failures and propose corrective actions. Evaluate
the most typical breast density.
Methods
and Materials: Clinical image quality criteria were evaluated
considering mammograms acquired in 13 DR systems and classified according
to PGMI scale using the criteria described in European Commission guidelines
for radiographers. The breast density was assessed according to ACR
recommendations. The data were collected on the acquisition system monitor
to reproduce the daily practice of the radiographer.
Results
The image quality criteria were evaluated in 3044 images. The
criteria were fully achieved in 41% of the images that were classified as
P (perfect), 31 % of the images were classified as M (moderate), 20% G (good)
and 9% I (inadequate). The main cause of inadequate image quality was
absence of all breast tissue in the image, skin folders in the pectoral muscle
and in the infra-mammary angle. The higher number of failures occurred in
MLO projections (809 out of 1022). The most represented (36%) breast type
was type 2 (25-50% glandular tissue).
Conclusion
Incorrect radiographic technique was frequently detected
suggesting potential training needs and poor communication between the team
members (radiographer and radiologists). Further correlations are necessary to
identify the main causes for the failures, namely specific education and training
in digital mammography and workload.
B-0275 14:45
Screening mammograms rejected due to positioning: does radiographer
experience and type of employment matter?
R. Hammond
1, K. Pedersen2, R. Gullien1, S. Sebuødegård1, P. Skaane1;
1Oslo/NO, 2Østerås/NO (
[email protected])
Purpose: Examine the dependence of rejection rate on experience and
employment type.
Methods
and Materials: From October 2011 to December 2012, a total of
85740 images were aquired. Of these images, 544 (0.63 %) were rejected for
positioning reasons. Indivi dual reject rates for 25 radiographers were
calculated. Experience in mammography, less or more than five years, and
type of employment, full time or part time, was registered. Seven radiographers
had less than, and 18 had more than five years of experience. Nine worked full
time and 16 part-time. Using logistic re gression, the odds for rejecting images
S194
BA C D E F G
Thursday
was modeled among radiographers with different experience and employment
status.
Results
The crude odds ratio for rejecting images is 1.20 (95% CI: 1.01-1.43)
for the full-time employed compared to the part-time employed radiographers,
and 0.53 (95% CI: 0.44-0.65) for the experienced radiographers compared to
the less experienced ones. Adjusting for these two factors results in a reduced
effect of type of employment from 1.20 to 1.05 (95% CI: 0.88-1.25). The effect
of experience remains constant when adjusting for type of employment
(OR=0.54, 95% CI: 0.44-0.66).
Conclusion
The reject rate was higher among the less experienced
radiographers and was not significantly influenced by type of employment.
Author Disclosures:
R. Hammond: Advisory Board; Hologic, Inc. 2012. Other; Travel costs 2012,
Hologic, Inc. K. Pedersen: Advisory Board; Hologic, Inc. 2012. R. Gullien:
Other; Travel costs 2012, Hologic, Inc. P. Skaane: Equipment Support
Recipient; Hologic, Inc. Research/Grant Support; Financial support when
overtime reading was necessary by Hologic, Inc.
B-0276 14:54
DICOM metadata-mining in PACS for computed radiography X-Ray
exposure analysis: a mammography multisite study
M.R.D. Santos, A. Silva, N. Rocha, P.S. Couto; Aveiro/PT (
[email protected])
Purpose: Extract DICOM Metadata from disperse Picture Archiving and
Communication Systems using the Dicoogle (www.dicoogle.com) system for
the x-ray exposure variation analysis in Computed Radiography
Mammographic studies.
Methods
and Materials: DICOM metada stored in several PACS sites were
extracted after Dicoogle user validation. Retrieved tag-value data elements
were used to objectively assess X-ray exposure. Due to its generalised
availability, the DICOM attribute "Sensitivity" was chosen as the main exposure
related parameter that was used to instance our approach in a mammographic
multi-site study spanning 2008-11 data. The Kruskal-Wallis statistical test was
used to characterise exposure variation patterns both for intra-site and inter-
site assessments.
Results
With the indexed retrieval process we efficiently assembled 8087
images, from 2047 studies belonging to 1757 patients. The detector x-ray
exposure values (S Value) analysis exhibited a reduction of radiation exposure
over time in institution B. In institution A a sharp increase was identified during
2009 and 2010 and a decreased during 2011. The variation of the exposure
values is statistically significant (p < 0.001). High standard deviation values,
associated with a high exposure levels, are themselves significant and may
Result
from mammographic studies performed with an x-ray overexposure or
underexposure.
Conclusion
The developed exposure assessment methodology shows that
the efficient mining of DICOM metadata , stored over disperse PACS archives
of radiology departments is possible and, may definitely contribute to quality
control initiatives at radiology departm ents, namely in radiation protection and
protocol optimisation scope.
B-0277 15:03
Visibility of cancer mimicking lesions in a polyvinyl alcohol breast
phantom using mammographic imaging: relationship between phantom
thickness and lesion visibility
M.S. Ossati, K. Szczepura, A.M. Marono, G.G. Wåde, J. Wilkinson, K. Boerma,
P. Sanderson, S. Kramer, S.S. Evensen, P. Hogg; Salford/UK
(
[email protected])
Purpose: To determine the relationship between lesion visibility and phantom
breast thickness in mammographic imaging.
Methods
and Materials: Two PVAL phantoms, each containing a contrast-
enhanced lesion, were evaluated. The mechanical and x-ray attenuation
properties of the phantoms/lesions were similar to fatty breast tissue and
malignant disease. Images were obtained , under different thicknesses, using
FFDM. Lesion visibility was assessed using visual analysis of the sharpness
and contrast using a 2 alternative forced choice (2 AFC). The lesion size was
measured and the contrast to noise ratio (CNR) was calculated.
Results
All results demonstrated a non-linear relationship between phantom
thickness and lesion visibility. The initial thickness was 45 mm. The average
2 AFC score in phantom 1 and phantom 2 ranged from 3.43 to 6.29 and 3.86
to 6.86, respectively, with the highest value at a thickness reduction of 40% in
phantom 1 and 62% in phantom 2. The CNR in phantom 1 and phantom 2
ranged from 3.00 to 9.68 and 4.29 to 10.69, respectively, with the highest value
at a thickness reduction of 62% in Phantom 1 and 49% in phantom 2. linear
relationship was shown between thickness reduction and the area of the
lesion.
Conclusion
For the deformable phantom, using 2 AFC, lesion visibility
increases as thickness reduces to a certain point, beyond which lesion visibility
deteriorates. Further research is necessary to understand why visibility
deteriorates.
B-0278 15:12
Radiographers practice concerning breast compression in
mammography: gradual versus no gradual
M. Bule, C.S.D. Reis; Lisbon/PT (
[email protected])
Purpose: Evaluate the type of breast compression (gradual or no gradual) that
provides less discomfort to the patient.
Methods
and Materials: The standard projections were simulated
[craniocaudal/(CC) and mediolateral-oblique/(MLO)] with the two breast
compressions in 90 volunteers women aged between 19 and 86. The women
were organised in groups according to the breast density. The intensity of
discomfort was evaluated using the sc ale that have represented several faces
(0-10) proposed by Wong Baker in the end of each simulation. It was also
applied an interview using focus group to debate the score that were attributed
during pain evaluation and to identify the criteria that were considered to do the
classification.
Results
The women aged between 19-29y (with higher breast density)
classified the pain during no gradual compression as 4 and the gradual
compression as 2 for both projections. The MLO projection was considered the
most uncomfortable. During the focus group interview applied to this group was
highlighted that compression did not promoted pain but discomfort. They
considered that the high expectations of pain did not correspond to the
discomfort that they felt. Similar results were identified for the older women (30-
50y; > 50y).
Conclusion
The radiographers should considerer the technique for breast
compression. The gradual compression was considered for the majority of the
women as the most comfortable regardless of breast density. The MLO
projection was considered as uncomfortable due to the positioning (axila and
inclusion of pectoral muscle) and due to the higher breast compression
compared to the CC projection.
14:00 - 15:30 Room P
Computer Applications
SS 205
Computer applications and dose reduction
Moderators:
F.H. Barneveld Binkhuysen; Soest/NL
M. Müller-Eschner; Heidelberg/DE
B-0279 14:00
Lesion size is a potential confounder for tumour heterogeneity assessed
with first order histogram features entropy and uniformity
M. Benndorf, M. Soschynski, S. Bucher, M. Windfuhr-Blum, M. Langer,
E. Kotter; Freiburg/DE (
[email protected])
Purpose: To investigate whether tumour heterogeneity measured with first
order histogram features depends on lesion size. Measurement of tumour
heterogeneity is considered to be an em erging tool for lesion stratification
according to histopathological type and survival prognosis.
Methods
and Materials: 68 consecutive breast MRI mass lesions (24 benign,
44 malignant) were retrospectively analysed. Tumours were manually
segmented in early contrast enhanced subtraction images that showed the
largest axial tumour diameter. For each tumour, mean, standard deviation,
skewness, kurtosis, empirical Shannon entropy [-1* -p (a)*log (p (a))] and
uniformity [-p (a)^2] were calculated.
Results
Malignant lesions showed higher entropy values (mean: 4.671) and
smaller uniformity values (mean: 0.012) than benign lesions (mean: 4.098 and
0.019, respectively, P < 0.01 each). Mean signal intensity was significantly
higher in malignant lesions, no difference was observed for standard deviation,
skewness and kurtosis of the tumours' si gnal intensity histograms. Receiver-
Operating-Characteristic (ROC) analysis yielded an AUC for entropy as
diagnostic variable of 0.792. However, benign lesions were in average smaller
than malignant lesions (P < 0.01, 9 mm versus 17 mm). Lesion size measured
in voxels per tumour yielded an AUC of 0.790 if used as diagnostic variable.
The DeLong method showed no significant difference of the ROC curves
(P=0.94). There was a strong correlation between entropy and lesion size
(Spearman correlation coefficient: 0.92).
Conclusion
Lesion size, since correlated with the independent variable
entropy and the outcome variable, is iden tified as a potential confounder for
studies that derive diagnostic thresholds for entropy and uniformity as
measures for tumour heterogeneity.
S195
BA C D E F G
Thursday
B-0280 14:09
Vessel probe reconstructions and 3D analysis software in the CT
characterisation of incidentally detected breast lesions
M. Moschetta, M. Telegrafo, A. Scardapane, V. Lorusso, L. Rella, G. Angelelli,
A. Stabile Ianora; Bari/IT (
[email protected])
Purpose: To evaluate the potential benefits of 320-row MDCT in the
evaluation and differential diagnosis of incidentally detected breast lesions by
using Vessel probe in MPR mode reconstructions and 3D analysis software
with net enhancement value.
Methods
and Materials: 62 breast lesions in 46 patients who underwent 320-
row chest CT examination because of different clinical issues were
retrospectively evaluated. CT scans were assessed searching for presence,
location, number, morphological features and density of breast nodules. NET
enhancement was calculated by subtracting pre-contrast density from the
density obtained by post-contrast values. Sensitivity, specificity, positive
predictive value (PPV), negative predictive value (NPV) and diagnostic
accuracy of CT were calculated firstly for morphological features and then for
dynamic behaviour.
Results
30/62 lesions were found to be malignant at histological examination.
32 nodules were found to be benign at histological examination. By considering
morphological features, sensitivity, specificity, accuracy, positive predictive and
negative predictive values were 87%, 100%, 88%, 100% and 50%,
respectively, for CT. Basing on NET enhancement, CT obtained sensitivity,
specificity, accuracy, positive predict ive and negative predictive values of
100%, 94%, 97%, 94% and 100%, respectively.
Conclusion
MDCT allows to recognise breast lesions and to suggest a
differential diagnosis of benign from ma lignant lesions basing on morphological
and dynamic features. Net enhancement can also be proposed as an
additional accurate CT feature.
B-0281 14:18
The impact of a novel iterative model-based reconstruction algorithm on
prosthetic heart valve related artifacts at reduced radiation dose
multidetector-row CT
D. Suchá
1, M.J. Willemink1, P.A. de Jong1, A.M.R. Schilham1, T. Leiner1,
P. Symersky2, R.P.J. Budde1; 1Utrecht/NL, 2Amsterdam/NL
(
[email protected])
Purpose: Prosthetic heart-valve (PHV) assessment with computed
tomography (CT) is thriving, but remains hampered by PHV-related artefacts
and high radiation-dose. The impact of a hybrid and prototype model-based
iterative-reconstruction method and dose reduction on PHV-related artefacts
and image quality (IQ) were assessed.
Methods
and Materials: One transcatheter (Edwards-Sapien) and two
mechanical (St. Jude, Medtronic-Hall) PHVs were embedded in diluted
contrast and imaged with retrospectively-ECG-gated CT. Eight scans were
acquired of each PHV at 120 kV, 600 mAs (routine) and 150 mAs (reduced-
dose). Data were reconstructed with filtered back-projection (FBP), hybrid
iterative-reconstruction (IR, iDose4) and model-based iterative-reconstruction
(IMR, Philips-Healthcare). Hypodense and hyperdense artefact-volumes were
measured by two threshold-filters. Signal-to-noise (SNR) and contrast-to-noise
(CNR) ratios were calculated. Statistical analysis was done with the Friedman-
test (significance: P < 0.05).
Results
Artefact-volumes differed significantly between reconstruction
algorithms for all PHVs and scans (P < 0.004). Compared to FBP, overall
hypodense and hyperdense artefact-volumes decreased by 4% and 1% (IR)
and 1% and 4% (IMR) at 600 mAs; and 53% and 20% (IR) and 67% and 23%
(IMR), respectively, at 150 mAs. Iterative-reconstruction increased SNR and
CNR at all doses (P < 0.001). At 150 mAs median SNR and CNR increased
from 5 and 5 (FBP) to 7 and 7 (IR) and 33 and 38 (IMR), respectively
(P < 0.001). Even at reduced dose, IMR resulted in higher IQ than routine dose
FBP and IR.
Conclusion
Iterative-reconstruction significantly reduced PHV-related artifacts
and improved IQ. With 75% reduced-dose IMR IQ was higher than with routine
dose FBP and IR. Thus, IMR allows for more radiation dose reduction than IR
while maintaining high IQ.
Author Disclosures:
R.P.J. Budde: Research/Grant Support; This study was supported by a grant
of The Dutch Heart Foundation [2009B014]. The department of Radiology,
University Medical Center Utrecht received Research Support from Philips
Healthcare.
B-0282 14:27
Influence of 4th generation iterative reconstruction system on image
quality in computed tomography in adults with acute appendicitis
M. Karul
1, S. Fokuhl1, S. Veldhoen2, H.D. Nagel3, M. Regier1, G. Adam1,
J. Yamamura1; 1Hamburg/DE, 2 Würzburg/DE,
3Buchholz in der Nordheide/DE (
[email protected])
Purpose: To define image quality of an iterative reconstruction (IR) system in
low-dose abdominal computed tomography (CT) in patients with
histopathologically proven appendicitis in an intraindividual comparison to
filtered back projection (FBP) and to evaluate dose reduction capability.
Methods
and Materials: 12 patients (mean BMI 23.6 kg/m 2) with appendicitis
underwent a preoperative reduced-dose 256-CT (RDCT) scan (Brilliance iCT;
80 eff. mAs; mean CTDI vol: 8.9 mGy). The raw data were reconstructed using
FBP and IR system (iDose4™, Philips, Best, the Netherlands) with two iteration
levels (4: 50% iteration; 6: 70% iteration). 12 other patients (mean BMI
24.1 kg/m2) with appendicitis who had undergone standard-dose CT (SDCT)
with FBP reconstructed images (mean exposure 140 mAs; mean CTDI vol:
632.8 ± 509.8 mGy; range 415-1193 mGy) served as reference standard. Two
blinded radiologists rated subjective im age quality and signs of appendicitis on
CT. Additionally, the objective image noise (OIN) was assessed.
Results
In RDCT iDose level 6 leads to a decrease in OIN (FBP vs. iDose:
psoas major muscle 64.4 vs. 49.3 HU), providing also significant improvements
in image quality and noise reduction compared to RDCT FBP images. The
detection of appendicitis signs e.g. periapp endiceal fat attenuation was limited
in RDCT FBP images. RDCT with iDose4™ level 6 was determined to be of
equivalent image quality as SDCT with FBP.
Conclusion
These pilot data propose that iDose4™ has potential to
remarkably improve image quality in reduced-dose abdominal CT in the
diagnosis of appendicitis while simultaneously reducing image noise.
B-0283 14:36
Evaluation of the effectiveness of rigid and deformable motion-correction
algorithms with regard to CT-perfusion measurements in abdominal
organs affected by breathing motion
S. Skornitzke, F. Fritz, M. Klauß, G. Pahn, L. Grenacher, H.-U. Kauczor,
W. Stiller; Heidelberg/DE (
[email protected])
Purpose: To evaluate the effectiveness of different motion-correction
algorithms and their effect on CT-perfusion map calculation in abdominal
organs affected by breathing motion.
Methods
and Materials: CT-perfusion sequences were dynamically acquired
over 51s (34 acquisitions every 1.5s) in five patients with recurrent pancreatic
carcinoma. Image data were motion-corrected throughout the dynamic
acquisition using commercially availa ble CT-perfusion software (BodyPCT,
Siemens Healthcare, Forchheim, Germany) or custom-developed deformable
registration (demons algorithm). Afte r motion-correction, perfusion maps were
calculated using a combined Maximum-Slope/Patlak-model (BodyPCT); R²-
value and residual of the perfusion model fit were determined. Two blinded
experienced radiologists rated motion-correction quality in terms of "in-plane"
and "out-of-plane" correction and "overall quality", and resulting perfusion
maps in terms of "vessel correction", "validity of perfusion values", and "overall
quality" on a five-point scale (1=worst, 5=best).
Results
Deformable registration scored higher (rating-criteria averaged mean
score 3.8) than BodyPCT (3.0) and a control group without motion-correction
(3.1; all p = 0.09). Perfusion maps were not affected
by choice of motion-correction method (p >= 0.09); average mean scores were
3.5 (deformable), 3.1 (BodyPCT), 3.0 (control). Average R² of deformably
registered images was higher (0.76/0.51/0.66) and residual lower
(0.033/0.079/0.044) than for rigid (BodyPCT) or without registration.
Conclusion
Deformable registration for motion-correction in abdominal
organs improves spatial alignment of the target region throughout the time
course of dynamic CT sequences, resulting in increased accuracy of perfusion
model fits. However, larger sample sizes are necessary for quantification of
motion-correction effects on perfusion maps.
S196
BA C D E F G
Thursday
B-0284 14:45
Denoising of HRpQCT scans via dicitionary learning for improved spatio-
temporal morphometry analysis
M.D. DiFranco, A. Valentinitsch, L. Fischer, C. Schueller-Weidekamm,
F. Kainberger, G. Langs; Vienna/AT (
[email protected])
Purpose: High-resolution quantitative CT (HRpQCT) images have shown
promise in studying in-vivo bone microarchitecture at the ultradistal extremities.
HRpQCT produces isotropic volumetric images at a resolution of 82 m.
Standard scans cover 9 mm of the distal radius or tibia and last 3 minutes with
a radiation dose < 3 Sv. Spatio-temporal morphometry (S TM) of longitudinal
HRpQCT scans involves rigid registration of baseline and follow-up scans,
segmentation of mineralised bone regions, and estimation of the magnitude
and directionality of local microarchitectural changes. However, noise in
HRpQCT images contributes errors at each step.
Methods
and Materials: We propose a 3D dictionary learning (DL) approach
to HRpQCT image denoising to improve S TM. DL enables sparse approximation
of image data through linear combinations of representative image patches
(the dictionary) in a two-step optimisation process. Radius HRpQCT scans
were acquired from a set of 23 cadaver arms. Parameters for 3D DL included
patch shape (cubic or spherical), patch size (3 to 7 voxels), dictionary size (128
to 640 elements), and the optimisation technique.
Results
Peak signal-to-noise ratio (PSNR) between the original and denoised
images was used to compare results. Patch size was found to be the most
relevant variable, with smaller patches leading to higher PSNR for both cubic
and spherical patches. PSNR, measured as decibels (dB), was seen with cubic
patches of size 3 (33.4±1.19) and spherical patches of diameter 5 (32.5 ±1.12).
Conclusion
We have assessed 3D dictionary learning as a method for
minimising noise while preserving fine structures in HRpQCT images.
B-0285 14:54
UNSCEAR survey system: a software platform to support the global
survey of medical radiation usage and exposures
A. Jahnen1, C. Moll1, F. Shannoun2; 1Luxembourg/LU, 2Vienna/AT
(
[email protected])
Purpose: The United Nations Scientific Committee on the Effects of Atomic
Radiation (UNSCEAR) established by the United Nations General Assembly in
1955 to assess and report levels and effects of all sources of ionizing radiation
conducts regular surveys on medical radiation exposure. A new web-based
platform with adequate software tools to support UNSCEAR's survey was
developed and will be presented.
Methods
and Materials: The software platform is composed of a web portal
accessible at http://survey.unscear.org that serves as a interface to
participating countries. National co ntact persons (NCP) need to register
themselves on the platform to be able to access it. After validation, the NCP
will have access to the countries private area, where they find specific
templates for Diagnostic Radiology, Interve ntional Radiology, Nuclear Medicine
and Radiotherapy. Only NCP are eligible to submit official countries data,
which will then undergo another validation step by scientific experts. The
national data will then inserted in the last component of the system, the
UNSCEAR Database for further processing and analysis.
Results
The UNSCEAR Survey System is composed of three major
components: the user portal that manages the collected data and the
participants, the dedicated spreadsheets that are used to provide the national
data and the UNSCEAR Database that store the data and the results of the
evaluation.
Conclusion
The new UNSCEAR Survey System will facilitate the data
collection and management process that will have a positive impact on the
outcomes of UNSCEAR's next Global Survey of Medical Radiation Usage and
Exposures.
B-0286 15:03
Assessment of the diagnostic value of virtual mono-energetic images
generated by a novel spectral-detector CT (SDCT) prototype
M.H. Gabbai, I.S. Leichter, Z. Romman, J. Sosna; Jerusalem/IL
(
[email protected])
Purpose: To compare diagnostic value of virtual mono-energetic 120 kVp
images with "conventional" abdominal CT images, generated by a single
spectral-detector CT (SDCT) acquisition.
Methods
and Materials: Following IRB approval and informed consent,
abdominal CT images of 30 patients (mean age 59) were acquired with a novel
SDCT prototype (Philips Healthcare, Cleveland, OH). The SDCT acquisition
parameters were 120 kVp and 59-259 mAs. For each SDCT study,
"conventional" CT images, comparable to those obtained by a standard MSCT
system, are generated along with virtual mono-energetic images in the range
40 keV to 140 keV. Two qualified radiologists assessed the overall diagnostic
value of mono-energetic images at 65 keV, compared to "conventional" SDCT
images using a scale of 1 to 4. Scores 3-4 indicated the mono-energetic image
showing reduced image artifacts and/or enhanced image contrast. The one
sample proportion test was applied.
Results
All reconstructed mono-energetic SDCT images at 65 keV were
diagnostic. Compared to conventional SDCT images, the mono-energetic
images were ranked as markedly better for 25 patients (83.3%), better for 3
(10%), and equivalent for 2 (6.7%), with a confidence level of 95%. Differences
between mean HU values for ROIs of the 65 keV virtual mono-energetic
images and conventional SDCT images at 120 kVp were 5.3 ±1.3 HU in the
aorta, 21±3.0 HU in cortical bone, 6.2 ±1.2 HU in the liver and 6.0 ±2.2 HU in fat
(p> 0.1).
Conclusion
Mono-energy images in most cases demonstrated improved
image quality with enhanced image contrast and artefact suppression
compared to conventional-SDCT abdominal images.
Author Disclosures:
Z. Romman: Employee; Philips. J. Sosna: Consultant; Actiview.
B-0287 15:12
Accuracy of coronary plaque detection using a semiautomatic plaque
analysis software in computed tomography coronary angiography
A. Laqmani1, T. Klink2, M. Quitzke1, D.D. Credner1, G. Adam1, G. Lund1;
1Hamburg/DE, 2Berne/CH (
[email protected])
Purpose: To assess the accuracy of coronary plaque detection with a
semiautomatic plaque analysis software in computed tomography coronary
angiography (CTCA) with a 256-MSCT scanner.
Methods
and Materials: Ten patients undergoing prospectively ECG-
triggered, axial CTCA on a 256-MSCT scanner (Brilliance iCT; tube
voltage,120 kVp; tube current-time product, 250 mAs; collimation, 2 x 128 x
0.625 mm, reconstructed slice thickness, 0.9 mm) were enclosed in this study.
All plaques were evaluated with a dedicated semiautomatic plaque analysis
software "Comprehensive Cardiac Analysis" (Extended Brilliance Workspace,
Philips Healthcare, Best, The Netherlands). After semiautomatic coronary
artery extraction automatically detected lesions are marked by the software as
plaques. The observers evaluated, if these automatically marked lesions
corresponded with visually detectable plaques. Potential reasons for a false-
positive plaque detection were analysed.
Results
The software automatically identified 114 structures as plaques. 32
(28%) of the automatically marked lesions complied with plaques (true-
positive). 82 (72%) of the lesions did not correspond with visually detectable
plaques (false-positive). 20 plaques were manually detected by observers but
not by the software (false-negative). For 82 false-positive detected plaques, the
following potential reasons were noticed by the observers: high density in
pericoronary fat (59%), vessel ramification (24%), contrast in adjacent veins
(6%), artery kinking (4%) and falsely contoured vessel (7%).
Conclusion
The evaluated semiautomatic plaque analysis software
demonstrates a very high false-positive detection rate of coronary plaques. A
revision of the software marked lesions as plaques is indispensable.
B-0288 15:21
Coronary CT angiography using 2° generation iterative reconstruction vs
filtered back projection: evaluation of image quality and radiation dose
saving potential. A validation study
C. Martini, L. Buttarelli, E. Rossi, M. De Filippo; Parma/IT
(
[email protected])
Purpose: To compare IQ of iterative reconstruction (SAFIRE) settings vs.
filtered back projection (FBP) in CT Coronary Angiography (CTCA).
Methods
and Materials: Twenty consecutive patients underwent CTCA for
suspected or known Coronary Artery Disease (CAD) with Dual-Source CT (CT
Flash, Siemens). Datasets were reconstructed using two standard FBP (B26-
B46) kernels and three comparable SAFIRE settings (S2, S3, S4). Vascular
attenuation and noise were measured. CT vascular attenuation values were
measured in: ascending aorta (Ao), right (RCA) and left (IVA) coronary artery,
respectively. Results were compared with ANOVA and Pearson's r correlation
coefficient. S/N and C/N were calculated. A p-value of 0.05 was considered
significant.
Results
We didn't find significant differences between attenuation values of
FBP and SAFIRE, except for the noise (p < 0.05). Infact, noise was 15, 12, 10,
9 HU in B26, S26-2,-3 and -4, respectively, and was 27, 20, 17, 16 HU in B46,
S46-2,-3 and -4, respectively. Comparing FBP with corresponding SAFIRE's
setting, ANOVA test showed significant differences in both RCA and IVA (B26
vs. S46-2,-3,-4, and B46 vs. S26-2,-3,-4). Lowest noise was found for SAFIRE
using S26-4 (9.6 HU) and I46-4 (15.6 HU). SAFIRE can provide S/N and C/N
significantly higher with increasing ke rnel sharpness. Moreover, the best S/N
and C/N was found for S26-3 and S46-4.
Conclusion
In CTCA, SAFIRE settings at medium (S3 in B26) and slowly
high strength (S4 in B46) can be used in clinical routines and may have more
potential than FBP for CAD evaluation improving diagnostic accuracy and/or
holding the potential for radiation dose reduction.
S197
BA C D E F G
S198
BA C D E F G
Friday
10:30 - 12:00 Room C
Cardiac
SS 503
Cardiac imaging: new horizons
Moderators:
T.R.C. Johnson; Munich/DE
J.-F. Paul; Le Plessis Robinson/FR
B-0289 10:30
Integrated and quantitative comparison of PET and MRI in acute
myocardial infarction
F. Nensa
1, T. Poeppel1, E. Tezgah1, P. Heusch2, K. Nassenstein1,
T. Schlosser1; 1Essen/DE, 2Düsseldorf/DE (
[email protected])
Purpose: To quantitatively compare positron emission tomography (PET) and
late gadolinium-enhancement (LGE) in the assessment of acute myocardial
infarction.
Methods
and Materials: Simultaneous cardiac PET/MRI (Biograph mMR,
Siemens Healthcare) with 18 F-fluorodeoxyglucose (18 F-FDG) was performed
in 25 patients with an acute occlusion of a coronary artery and interventional
recanalisation. Cine, T2-weighted and LGE images were acquired in parallel to
an ECG-gated PET scan. Infarcts were categorised into 1-25%, 26-50%, 51-
75% and 76-100% transmurality in LGE images. Short-axis LGE and PET
images were processed and transformed into co-registered polar (bull's eye)
plots using dedicated software developed in-house. Segment wise (90
segments/slice; 630-990 segments/scan) inter-method correlation was
calculated with weighted Pearson's product-moment correlation coefficients.
Binary inter-method agreement in infarct delineation was calculated as Cohen's
kappa.
Results
Median correlation coefficient was -0.16 ±0.21, -0.48±0.14, -0.73±0.08
and -0.79± 0.10 for 1-25%, 26-50%, 51-75% and 76-100% transmurality,
respectively. Median kappa was 0.04± 0.19, 0.34 ±0.19, 0.77 ±0.16 and
0.81±0.14 for 1-25%, 26-50%, 51-75% and 76-100% transmurality,
respectively. Mean infarct size in LGE images was 32.2 ±14.3 ml and
41.7±31.1 ml in PET images. In 11 patients with visually conclusive agreement
between PET and LGE, the defect was significantly (p=0.03) larger in PET
images. In 6 patients no LGE but a clearly reduced 18 F-FDG uptake was
found in the perfusion territory of the occluded coronary artery.
Conclusion
Concordance between PET and LGE was dependent on infarct
transmurality and therefore associated with high agreement in transmural and
relatively poor agreement in subendocardial infarcts. However, reduced 18 F-
FDG uptake seemed to correspond with the area-at-risk.
B-0290 10:39
Comparison of cardiac function in synchronously acquired Hybrid PET-
MRI data
C. Lücke, P. Werner, T. Jochimsen, I. Eitel, M. Grothoff, H. Barthel, O. Sabri,
M. Gutberlet; Leipzig/DE (
[email protected])
Purpose: To determine and compare the cardiac function in synchronously
acquired Hybrid PET-MRI data sets.
Methods
and Materials: In 10 patients (8 male, 2 female, mean age 48 ± 18
years), who underwent a [18 F]-FDG-PET-CT due to a non-cardiac indication
and showed a homogenous cardiac FDG uptake, a synchronous PET-MRI
(Biograph mMR, Siemens, Erlangen, Germany) was performed with the
residual activity of the previous invest igation. The PET acquisition time was
15 min, while simultaneously standard cine sequences were acquired in short
axis, two- and four-chamber orientation. PET and MRI data were evaluated by
two investigators blinded to the results of the other method. The left ventricular
end-diastolic volume (EDV) and end-systolic volume (ESV), ejection fraction
(EF) and left ventricular myocardial mass (MM) were measured and mean
differences (MD) were calculated. Pearson correlation coefficients ( r) were
determined and a Bland-Altman analysis was conducted.
Results
The comparison showed a good correlation of cardiac function
parameters (EDV: r = 0.94; ESV: r =0.88, MM: r =0.71, EF: r=0.72). The MD of
EDV was 5 ±8 ml in favor of the PET, ( p=0.67), ESV was measured the same
size (MD 0 ± 7 ml, p=0.99). EF showed with a MD of 1 ± 7%, no significant
difference between the two methods ( p=0.78). The MM was measured
19 ± 15 g (p
< 0.05) greater with PET than with MRI.
Conclusion
In simultaneously acquired cardiac PET/MR data EDV, ESV and
EF show a very good agreement. Only the left ventricular wall mass shows a
statistically significant difference in favor of the PET.
B-0291 10:48
Validation of coronary CT angiography-derived fractional flow reserve
with catheter-based fractional flow reserve
A. Coenen, A. Kurata, A. Dedic, M. Lubbers, M.L. Dijkshoorn, M. Ouhlous,
R. van Geuns, G.P. Krestin, K. Nieman; Rotterdam/NL
(
[email protected])
Purpose: Catheter-based fractional flow reserve (FFRCath) has become the
Reference
standard to determine the functional severity of angiographic
coronary artery disease (CAD). The feasibility of non-invasive estimations of
functional severity from anatomical coronary CT angiography (CCTA) images
using computational fluid dynamics has recently been reported. In this study,
we investigate the performance of CCTA-derived fractional flow reserve
calculation (FFRCT) compared with FFRCath and determine the incremental
diagnostic value of FFRCT over CCTA.
Methods
and Materials: We evaluated the diagnostic performance of a novel
FFRCT algorithm (Siemens Medical Solutions, Forchheim, Germany) that can
be performed on-site without transfer of data. Based on the left ventricular
mass, coronary anatomy derived from CCTA and several hemodynamic
parameters, FFRCT can be computed. In this study, we included 101 patients
who underwent a CCTA followed by a FFRcath within 50 days. FFRCT and
FFRcath results are compared using Spearman's coefficient and Bland-Altman
analysis. In addition, the incremental value of FFRCT over CCTA will be
determined using C-statistics.
Results
Baseline characteristics: mean age 62 years, 79% male, 17% with
history of diabetes and average calcium score 744. In these 101 patients, 181
vessels were interrogated with an FFR catheter, of which 77 vessels were
considered haemodynamically obstructed (FFRCath 0.80). We preformed
CCTA-derived coronary artery lumen segmentations in all 101 patients. At the
time of abstract submission, FFRCT analysis with the latest iteration of the
work-in-progress software was ongoing.
Conclusion
We will report the diagnostic performance of a new algorithm for
CCTA-based FFRCT.
Author Disclosures:
K. Nieman: Research/Grant Support; Grant from Siemens Medical Solution,
for a previous unrelated study.
B-0292 10:57
A virtual two-dimensional cardiac phantom for calculation of regional left
ventricular strain using non-rigid image registration
S.A. Sorrentino1, M.J. Peperhove1, T. Kaireit1, J. Strehlow2, J. Ruehaak2,
F. Wacker1, J. Vogel-Claussen1, H.-o. Shin1; 1Hannover/DE,
2Lübeck/DE (
[email protected])
Purpose: To evaluate a non-rigid image registration algorithm for left
ventricular (LV) strain measurements on a virtual LV phantom and to establish
a method to compute circumferential and radial strain using cine-gated, non-
tagged MR images.
Methods
and Materials: A two-dimensional virtual LV phantom was
developed, recreating a series of twen ty-nine circular masks simulating the
midventricular plane of short-axis cine MR images of the left ventricle. Non-
rigid image registration was performed, using the resulting deformation field for
quantification of circumferential and radial strains (" virtual tagging"). The virtual
LV phantom was further divided in four segments. Statistical analysis was done
using Pearson correlation coefficient calculations.
Results
Strain values from virtual tagging were highly correlated with the real
values. Overall peak circumferential strain determined by virtual tagging
differed 1.6% from real values (r
2 = 0.97; P < 0.0001). Overall peak radial strain
determined by virtual tagging differed 0.8% from real values (r 2 = 0.98;
P < 0.0001). When dividing the phantom into four segments, circumferential
strain determined by virtual tagging differed 4.4 - 6.3% from real values (r 2 =
0.95; P < 0.0001) and radial strain differed 1.2 - 2.9 % from real values (r 2 =
0.95; P < 0.0001).
Conclusion
Circumferential and radial strain values computed from non-rigid
registration followed by analysis of the resulting deformation field (virtual
tagging) correlate significantly with real values of a virtual LV phantom, making
it a promising tool to compute strains using cine-gated, non-tagged MR
images.
S199
BA C D E F G
Friday
B-0293 11:06
Evaluation of epicardial adipose tissue using CT angiography: evaluation
of a prototype software
J.V. Spearman, F.G. Meinel, U.J. Schoepf, A.W. Krazinski, P. Apfaltrer,
A.D. McQuiston, C. Canstein, C.N. De Cecco, L.L. Geyer; Charleston, SC/US
(
[email protected])
Purpose: This study evaluated the performance of a novel automated software
tool for epicardial fat volume (EFV) quantification compared to a standard
manual technique at coronary CT angiography (cCTA).
Methods
and Materials: cCTA data sets of 70 patients (58.6 ±12.9years, 33
men) were retrospectively analysed using two different post-processing
software applications. Observer 1 perform ed a manual single-plane pericardial
border definition and EFVM segmentation (manual approach). Two observers
used a software program with fully-automated 3D pericardial border definition
and EFVA calculation (automated approach). EFV and time required for
measuring EFV (including software processi ng time and manual optimisation
time) for each method were recorded. Intra-observer and inter-observer
reliability was assessed on the prototype software measurements. T test,
Spearman's rho, and Bland Altman plots were used for statistical analysis.
Results
The final EFVA (with manual border optimisation) was strongly
correlated with the manual axial segmentation measurement (60.9 ±33.2 mL
vs.65.8±37.0 mL, rho=0.970, P < 0.001). A mean of 3.9 ±1.9 manual border
edits were performed to optimise the automated process. The software
prototype required significantly less time to perform the measurements
(135.6±24.6s vs. 314.3±76.3s, P0.9).
Conclusion
Automated EFVA quantification is an accurate and time saving
Method
for quantification of EFV compared to established manual axial
segmentation methods
Author Disclosures:
U.J. Schoepf: Grant Recipient; Bayer, Bracco, GE, Medrad, Siemens. C.
Canstein: Employee; Siemens.
B-0294 11:15
Feasibility study of free-breathing diffusion tensor imaging in porcine
acute myocardial infarction model
J.-W. Kang1, S. Choi2, W. Lee1, T.-H. Lim1; 1Seoul/KR, 2Ulsan/KR
(
[email protected])
Purpose: To evaluate the feasibility of in vivo DT-MRI without breath-hold with
regard to changes in direction-dependent wa ter diffusivity refl ecting alterations
in tissue integrity such as apparent diffusion coefficients (ADC), fractional
anisotropy (FA), and fiber length.
Methods
and Materials: Acute myocardial infarction (AMI) was induced by
ligation of mid segment of left anterior descending coronary artery (LAD) in
sixteen pigs. DT-MRI using a SENSE-based echo-planar imaging technique
was acquired using a 1.5-tesla MR scanner with free-breathing state using
navigator sequence. With a b-value of 300 s/mm
2, the diffusion tensor images
were obtained for 6 diffusion-sensitizing gradient directions at infarcted zone at
the mid-ventricular level. Image quality of the acquired DTI was evaluated. The
ADC, FA, and the fiber length were measured for quantitative analysis.
Results
Image quality was good in 3 pigs, fair in 2 pigs, and poor in 2
pigs.The infarct zone showed significantly increased ADC than that of the
remote zone (8.097 ± 3.741 × 10
-3 mm2/sec versus 5.894 ± 2.985 × 10 -
3 mm2/sec, P=0.018). The FA of the infract zone was seen to be also
significantly lower than that of remote zone (0.393 ± 0.972 versus
0.485 ± 0.145, P=0.018). The fiber length in the infarct zone was seen to be
significantly shorter than the remote zone (17.57 ± 5.46 mm versus
24.84 ± 9.79 mm, P=0.018).
Conclusion
In vivo DT-MRI's of post-infarct myocardium with fair or good
image quality can be acquired and the results correlated well with those of ex-
vivo and breath-hold studies.
B-0295 11:24
New micro angiographic system for evaluation therapeutic effects of C-kit
positive cardiac stem cells
C. Tanaka; Isehara-city, Kanagawa/JP (
[email protected])
Purpose: Recently, the number of heart failure by ischaemic disease is
increasing. Tissue engineering is hopeful, however, the evaluating tools are not
sufficient. We developed microangiographic system, and assessed therapeutic
effects.
Methods
and Materials: The system we developed has a cerium anode which
has characteristic X-ray around 34.6 Kev. It is close to K-edge of contrast
Materials
(Iodine and Barium), therefore, the system can detect tiny amount of
iodine. C-kit positive cardiac stem cells (CSCs) were isolated and cultivated by
left auricles of dogs. Acute myocardial infarction (AMI) was made at the apex,
and the cultured autologous CSCs were injected directly to the cardiac wall of
the ischaemic area in 5 dogs (CSCs group). One month later, the hearts were
excised and the coronary artery was full-filled with barium. Then, they were
radiated by the system. In other five dogs, the cardiac wall of the ischaemic
area was injected with saline (saline group).
Results
We lost 2 dogs in CSCs group and 3 dogs in saline group due to
lethal arrhythmia. In CSCs group, a lot of newly formed vessels were visualised
at the apex. They were meandering with irregularities. The minimum diameter
of vessels was 50 8m. The new vessels were visualised in all dogs in CSCs
group. Besides, avascular area was visualised at the apex without new vessels
in saline group.
Conclusion
The therapeutic effects of CSCs for ischaemic disease were
evaluated by visualising newly formed vessels. Our microangiographic system
is useful for the evaluation.
B-0296 11:33
Feasibility of an ultra-low dose CT for left atrium and pulmonary veins
imaging using VEO (model-based iterative reconstruction)
A.D. Annoni, A. Formenti, G. Pontone, E. Nobili, M. Petullà, S. Mushtaq,
G. Ballerini, M. Pepi, D. Andreini; Milan/IT (
[email protected])
Purpose: To evaluate the feasibility of ultra-low dose CT for left atrium and
pulmonary veins imaging using VEO (model-based iterative reconstruction).
Methods
and Materials: 120 patients with persistent or intermittent atrial
fibrillation before catheter ablation were enrolled in our study. Patients were
randomised into 2 groups: Group 1 (60 pts, MDCT with VEO, no ECG
triggering, 100 kV and 60 mA, irrespective of patient BMI) and Group 2 (60 pts,
MDCT with standard acquisition, ECG triggering, ASIR, kV and mA tailored on
patient BMI). The image quality (graded as good, adequate and poor) was
evaluated by two reviewers. The CT-attenuation, image noise, signal-to-noise
ratio (SNR), contrast-to-noise ratio (CNR) of left atrium and every pulmonary
vein branch and Effective Dose (ED) were evaluated and compared between
two groups.
Results
No differences were found between two groups in terms of gender
and BMI and image quality score. No significant differences were found in CT-
attenuation of left atrium and pulmonary veins between two groups but
statistically significant differences were found between Group 1 and Group 2 in
SNR, CNR and noise of left atrium (26.2 ±7.6 versus 14.1±4.4, p < 0.00001 and
23.06±7.09 versus 12.06 ±3.8, p < 0.00001, respectively) and of pulmonary
veins. Group 1 patients showed a significantly lower mean ED in comparison
with Group 2 (0.5±0.05 versus 5.07±3.3 mSv).
Conclusion
The CT for left atrium and pulmonary veins imaging using VEO is
feasible and allows to perform the examination with very low radiation
exposure and good image quality.
B-0297 11:42
Magnetic resonance imaging at 1.5 Tesla in patients with a subcutaneous
implantable cardioverter-defibrillator (S-ICD)
J. Keller
1, P. Neuil1, J. Vymazal1, J. Weichet1, M. Janotka1, J. Brada1,
R. áek1, V.Y. Reddy2; 1Praha 5/CZ, 2New York, NY/US
(
[email protected])
Purpose: The aim of our study was to evaluate the safety of imaging in
patients with a new type of implantable cardioverter-defibrillator called the S-
ICD in a 1.5 T MRI scanner. With the increasing number of patients with
cardiac implantable devices who are indicated for MRI, there is a growing need
for establishing MRI compatibility of cardiac implantable devices. We present
the first cohort of patients implanted with an S-ICD and safely scanned with a
1.5 T MRI.
Methods
and Materials: Patients with implanted S-ICD systems underwent
MRI scan of one or more anatomical area. The S-ICD were programmed off
and patients were monitored by ECG throughout the imaging procedure.
Device function was evaluated pre and post-scan. A thermistor probe was
used to monitor temperature changes in the area above the subcutaneous
pocket with SICD and patients were asked to report immediately any pain,
torqueing movement or heating sensation in the area of either the pocket or
electrode.
Results
Thirteen patients underwent a total of 17 examinations at 1.5 T.
Scans included brain, spine and cardiac imaging. Two patients were re-
scanned due complaints of heating over the pocket during lumbar scans,
caused by a thermistor probe placed on the skin to measure skin temperature.
Rescan without the probe and all the remaining scans were performed without
incident. No evidence of device malfunction was obversed.
Conclusion
MRI of patients with the implanted S-ICD can be performed
safely under controlled conditions. This study was supported by Research
Project Charles University in Prague, PRVOUK P34.
S200
BA C D E F G
Friday
B-0298 11:51
Noninvasive measurement of coronary flow velocity reserve by phase-
contrast cine MRI at 3 T in the detection of stenosis in the major three
coronary arteries
T. Higashigawa
1, Y. Ichikawa1, M. Ishida2, D. Izumi1, T. Kouiji1, K. Matsuoka1,
K. Kitagawa2, T. Hirano1, H. Sakuma2; 1Matsusaka/JP, 2Tsu/JP
(
[email protected])
Purpose: Coronary flow velocity reserve (CFVR) can be noninvasively
measured by phase-contrast cine MRI (PC-MRI). To date, CFVR measurement
has been studied with 1.5 T system and mainly limited to LAD artery. With 3 T
system, however, PC-MRI may allow reliable flow quantification not only in
LAD artery but also in RCA and LCX artery due to improved spatial and
temporal resolution. The purpose of this study was to evaluate the feasibility of
3 T MR measurement of CFVR for detecting significant stenosis in three major
coronary arteries.
Methods
and Materials: Sixteen patients (71 ±9 years) with suspected
moderate coronary stenosis on CT angiography were included. CFVR was
measured perpendicular to the coronary arteries (total 26 vessels [RCA, 11;
LAD, 10; LCX, 5]) using breath-hold PC-MRI at rest and during adenosine
triphosphate (ATP)-induced hyperemia with 3 T MR system (Ingenia 3 T,
Philips) by two observers. Measurements were compared with quantitative
coronary angiography (QCA).
Results
CFVR was successfully determined in 25/26 (96%) vessels.
Moderate inverse correlation was found between CFVR and coronary stenosis
on QCA (r=-0.57, p=0.002). Using a threshold of 1.5 for CFVR, the sensitivity,
specificity, and positive and negati ve predictive value for detecting 50%
stenosis on QCA was 83%(5/6), 85%(17/20), 63%(5/8), 94%(17/18),
respectively. Intra-class correlation coefficient between CFVR measurements
by two observers was 0.82, showing a good inter-observer reproducibility.
Conclusion
CFVR can be determined in three major coronary arteries with a
high success rate by using breath-hold PC-MRI at 3 T, and has a great
potential for noninvasive assessment of physiologic significance of coronary
arterial stenosis.
10:30 - 12:00 Room D
Chest
SS 504
Vascular imaging and thromboembolic
disease
Moderators:
B. Feragalli; Chieti/IT
T. Frauenfelder; Zurich/CH
B-0299 10:30
Ultra-low dose CT pulmonary angiography reconstructed with a model-
based iterative reconstruction: comparison with standard CT pulmonary
angiography. A prospective non-inferiority trial
X. Montet, A.-L. Hachulla, A. Neroladaki, D. Botsikas, C.D. Becker; Geneva/CH
(
[email protected])
Purpose: To compare quantitative and qualitative image quality and radiation
dose between CT pulmonary angiography (CTPA) reconstructed with filtered
back projection (FBP) and ultra-low dose CTPA reconstructed with model-
based iterative reconstruction (MBIR).
Methods
and Materials: This prospective study was approved by the
institutional review board and each patients provided written informed consent.
Eighty-two patients were scanned with an ultra-low dose CTPA (100 kV,
20 mA) and eighty-two patients were scanned with a classical CTPA (100 kV,
250 mA). Region of interests were drawn in nine pulmonary vessels; signal-to-
noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-
point scale was used to subjectively evaluate the quality of CTPA and ultra-low
dose CTPA.
Results
Compared to standard CTPA, ultra-low dose CTPA (reconstructed
with MBIR) showed no differences in density measured in 9 pulmonary
vessels, higher SNR (p < 0.0001) and higher CNR (p < 0.0001) despite a dose
reduction of 93 % (p < 0.0001).
Conclusion
Ultra-low dose CTPA reconstructed with MBIR allows a
significant dose reduction while improving SNR and CNR in the pulmonary
vessels, as compared with classical CTPA reconstructed with FBP.
B-0300 10:39
Iterative reconstruction in single source dual-energy CT pulmonary
angiography: Is sufficient to achieve a radiation dose as low as state-of-
the-art single-energy CTPA?
M. Ohana, M.-Y. Jeung, A. Labani, S. El-Ghannudi, C. Roy; Strasbourg/FR
(
[email protected])
Purpose: Single-source dual-energy CT pulmonary angiography (DE-CTPA)
induces an increase of radiation dose going up to 40% when compared to a
single-energy examination. Our goal wa s to cancel this increase by using
iterative reconstruction (ASIR).
Methods
and Materials: Fifty patients (60% men, 65.8 yo ±15.4,
BMI=25.9±4.6) were prospectively included and underwent single-source DE-
CTPA with following acquisition parameters: 80/140 kV, 0.6 s rotation time,
275 mA fixed tube current, 50% ASIR. Parameters were tweaked to target a
radiation dose similar to a 100 kV single-energy CTPA (DLP of 250 mGy.cm).
Thirty patients (46% men, 64.4 yo ±18.6, BMI=26 ±4.6) from a previous
prospective study on DE-CTPA (375 mA fixed tube current, no ASIR) were
used as the reference group. Subjective image quality was scored by two
radiologists using a 5-level scale. Meas ures of signal intensity and noise on 65
keV monochromatic reconstructions were used to calculate signal-to-noise
(SNR) and contrast-to-noise (CNR) ratios.
Results
All examinations were of diagnostic quality (score 3). Compared with
the reference DE-CTPA protocol, ASIR effectively achieved a spectacular dose
reduction (DLP of 243 mGy.cm VS 388, p < 0.01), with a preserved image
quality (4.4/5 VS 4.6, p=0.23) and an equivalent SNR (16.4 VS 14.9, p=0.27)
and CNR (14.1 VS 12.7, p=0.28). SNR, CNR and image quality were
negatively correlated with Body Mass Index, which could therefore be used to
adjust radiation dose to the patient's morphology.
Conclusion
Thanks to iterative reconstruction, single-source DE-CTPA can
be achieved at diagnostic quality with a radiation dose no greater than a single-
energy examination (DLP of 243 mGy.cm).
B-0301 10:48
Combined MR imaging of acute pulmonary embolism and deep vein
thrombosis: diagnostic accuracy of unenhanced balanced steady-state
free precession and contrast-enhanced 3D gradient echo sequences
N. Karabulut, F. Kaya, I. Yilmaz, D. Herek; Denizli/TR
(
[email protected])
Purpose: To evaluate diagnostic performance of combined MR imaging in
pulmonary embolism (PE) and deep vein thrombosis (DVT).
Methods
and Materials: Combined pulmonary and lower extremity MR
imaging and Doppler sonography were performed in 29 patients (18 men, 11
women) within 72 hours after computed tomography angiography (CTA). MR
technique included two sequences: unenhanced balanced steady-state free
precession (SSFP), and contrast-enhanced three-dimensional (3D) gradient-
echo (GRE). Two reviewers analysed CT angiography and each MR sequence
and recorded the presence of emboli in pulmonary arteries and thrombi in
lower extremity veins. Diagnostic accuracy of each MR technique was
calculated using CTA (in chest) and sonography (in lower extremities) as the
Results
A total of 210 emboli were detected in 18 (62%) patients on CTA.
DVT was detected in 21 (72%) on sonography. Sensitivities for SSFP vs 3D
GRE MR respectively in PE detection were 52% vs 62% on a per-embolus
basis, and 52% vs 94% on a per-patient basis.
Sensitivities for SSFP vs 3D GRE MR respectively in DVT detection were 73%
vs 80% on a per thrombus basis, and 85% vs 93% on a per-patient basis. Five
(28%) patients without PE showed DVT, whereas two patients without DVT
had PE.
Conclusion
Combined MR imaging of acute PE and DVT is a one-stop-
shopping examination and may be considered a second-line modality in
patients with contraindications to CTA. Unenhanced SSFP can be used for
diagnosing PE or DVT in pregnant patients.
B-0302 10:57
Decreased left atrial volume predicts higher mortality in patients with
acute pulmonary embolism
E. Soikher, S. Adam, H. Shmueli, S. Berliner, Y. Sagi, A. Meilik, Y. Amitai,
U. Bendet, G. Aviram; Tel Aviv/IL (
[email protected])
Purpose: To investigate the association between the volumes of the right and
left cardiac ventricles and atria with adverse prognosis in acute pulmonary
embolism (PE) using CT pulmonary angiography (CTPA).
Methods
and Materials: We retrospectively analysed 450 consecutive
patients diagnosed with acute PE by non-gated CTPA between 1.1.2009 and
31.12.2010. Each CTPA was investigated by measuring the right ventricular
(RV) and left ventricular (LV) diameter ratio, and by a novel volumetric analysis
software which provides the volumes of the LV, RV, right atrium (RA) and left
atrium (LA) automatically. The association with 30 days mortality was
analysed.
Results
Seventy-nine (17.5%) patients were excluded due to technical and
patient-related factors. Out of 371 patients that were included in the final study
group, 39 (10.5%) died within 30 days. Mortality was significantly associated
with reduced LA volumes (odds ratio =1.49, P=0.016 for 20 ml decrease) and
S201
BA C D E F G
Friday
higher ratios between the volumes of RA/LA (odds ratio =1.91, P=0.031). No
significant association was found between mortality and RV/LV diameters, RV,
LV and RA volumes, age and gender. Analysis of the influence of various
measurements on mortality revealed that RA/LA volume ratio was the best
predictor, with a mortality of 19.8% for the 111 patients with the RA/LA volume
ratio 1.315, and of 6.5% among the 260 patients with RA/LA volume ratio
< 1.315 (P=0.003).
Conclusion
RA/LA volume ratio 1.3 is associated with higher mortality in 30
days. Volumetric analysis of the heart using CTPA data may be useful for risk
stratification in acute PE.
Author Disclosures:
G. Aviram: Research/Grant Support; Philips Healthcare.
B-0303 11:06
Dual-energy CT perfusion and angiography in chronic thromboembolic
pulmonary hypertension: diagnostic accuracy and concordance with
radionuclide scintigraphy
G. Dournes, D. Verdier, M. Montaudon, A.-L. Riviere, C. Dromer, F. Picard,
M.-A. Billes, F. Laurent, M. Lederlin; Bordeaux/FR (
[email protected])
Purpose: To evaluate the diagnostic accuracy of dual-energy computed
tomography (DECT) perfusion and angiography versus ventilation/perfusion
(V/Q) scintigraphy in chronic throm boembolic pulmonary hypertension
(CTEPH), and to assess the per-segment concordance rate of DECT and
scintigraphy.
Methods
and Materials: Forty consecutive patients with proven pulmonary
hypertension underwent V/Q scintigraphy and DECT perfusion and
angiography. Each imaging technique was assessed for the location of
segmental defects. Diagnosis of CTEPH was established when at least one
segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy
of DECT perfusion and angiography was assessed and compared with
scintigraphy. In CTEPH patients, the per-segment concordance between
scintigraphy and DECT perfusion/angiography was calculated.
Results
Fourteen patients were diagnosed with CTEPH and 26 with other
aetiologies. DECT perfusion and angiography correctly identified all CTEPH
patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At
a segmental level, DECT perfusion showed moderate agreement ( 5=0.44) with
scintigraphy. Agreement between CT angiography and scintigraphy ranged
from fair ( 5=0.31) to slight ( 5=0.09) depending on whether completely or
partially occlusive patterns were considered, respectively.
Conclusion
Both DECT perfusion and angiography show satisfactory
performance for the diagnosis of CTEPH. DECT perfusion is more accurate
than angiography at identifying the segmental location of abnormalities.
B-0304 11:15
Impact of perfusion imaging on the assessment of peripheral chronic
pulmonary thromboembolism (CPTE): clinical experience in 62 patients
F. Molinari, J. Le Faivre, F. Pontana, K. Yasunaga, J. Remy, M. Remy-Jardin;
Lille/FR (
[email protected])
Purpose: To evaluate the impact of perfusion imaging on the detection of
peripheral chronic pulmonary thromboembolism (CPTE).
Methods
and Materials: 62 patients with CPTE underwent a dual-source,
dual-energy CT angiographic examination with (a) reconstruction of diagnostic
(i.e., averaged images from both tubes) and pulmonary blood volume (PBV)
images; (b) enabling separate depiction of peripheral chronic CPTE on
diagnostic images and perfusion defects on MPRs of PBV images. On
diagnostic scans, the CT features of peripheral CPTE included stenosed
arterial branches and/or endoluminal filling defects within segmental and
subsegmental arteries. On PBV images, pulmonary embolism-type defects
consisted of triangular, pleural-based and sharply marginated hypoattenuated
areas which were recorded at a segmental level (20 segments/patient; total:
1240 segments). The readings of diagnostic and perfusion images were
independently performed by two readers.
Results
On diagnostic images: (a) the analysis of segmental arteries depicted
CT features of CPTE within 476 segments; (b) the analysis of both segmental
and subsegmental arteries depicted CT features of CPTE within 872
segments. PBV imaging de picted: (a) 313 segments with perfusion defects at
the level of which segmental arteries had not been diagnosed with CPTE,
increasing the number of segments affected by CPTE by 66% (313/476); (b)
66 segments with perfusion defects at the level of which subsegmental arteries
had not been diagnosed with CPTE, increasing the number of segments
affected by CPTE by 7.5% (66/872).
Conclusion
The reading of PBV im ages enables depiction of a greater
number of segments involved in peripheral CPTE.
B-0305 11:24
Correlation between DE-CTPA-based iodine map defect extensions and
clinical parameters in patients with chronic thromboembolic pulmonary
disease detected at DECT: an initial experience
M. Paoletti, C. Capone, D. Stoppa, A. Valentini, E.M. Bassi, M. Morsolini,
V. Grazioli, A.M. D'Armini, R. Dore; Pavia/IT
Purpose: To determine if perfusion-based iodine map generated by
postprocessing of DE-CTPA (dual-energy computed tomography pulmonary
angiography) data can correlate wi th mPAP (mean pulm onary arterial
pressure) and PVR (pulmonary vascular resistance) and the extension of
vascular disease in patients with chronic thromboembolic pulmonary disease.
Methods
and Materials: 33 consecutive patients with chronic thromboembolic
pulmonary disease (18 men and 15 women, mean age 56) underwent DE-
CTPA. Patients were divided into two groups: group A: 12 pts,
mPAP < 25 mmHg, NYHA 2-4; group B: 21 pts, mPAP 25 mmHg, NYHA 2-4.
Postprocessing was used to generate iodine-distribution maps. A two-
operators-based subjective evaluation and a semi-automatic quantification of
perfusion defects were performed. A modified Qanadli score was performed to
assess the vascular obstruction in the pulmonary vascular tree in the whole
population and in the two groups. The parenchymal density assessment was
performed by a dedicated software.
Results
There was a statistical significant difference between the two groups
(p < 0.01) considering the subjective perfusi on quantification and the vascular
obstruction score. The study also s howed a moderate positive correlation
between the subjective perfusion score and both mPAP and PVR; a moderate
negative correlation was present between the obstruction score and mPAP. No
clear correlation was evident comparing mPAP and PVR with the parenchymal
density and the semi-automatic perfusion quantification.
Conclusion
Subjective perfusion quantification and the modified Qanadli
score demonstrated a greater disease degree in the group with mPAP
25 mmHg. A correlation exists between the clinical parameters and the
subjective perfusion quantification.
B-0306 11:33
Complex contrast injection protocol reduces inflow streak artefacts at the
cervico-thoracic junction during computed tomography of the thorax
C. Saade, M. Hourani; Beirut/LB (
[email protected])
Purpose: To investigate enhancement of thoracic vasculature during
computed tomography (CT) of the thorax using a complex injection contrast
protocol.
Methods
and Materials: 300 patients underwent routine post-contrast thorax
CT using a 64 channel CT scanner. Patients were allocated to one of two
contrast protocols: Protocol A, the depar tment's standard protocol, consisting
of a caudocranial scan direction with 100 mL of contrast intravenously injected
as a single bolus; Protocol B, involving a caudocranial scan direction and
100 mL of contrast using a complex injection protocol. Each protocol employed
a dual barrel injector with 100 mL of saline and a fixed scan delay of 70 sec
prior to acquisition. Attenuation profile s of the thoracic arteries and veins were
measured with the arteriovenous contrast ratios (AVCR) calculated. Receiver
operating characteristic (ROC) analysis was performed using DBM
methodology.
Results
Arterial attenuation was up to 24% (p < 0.03) higher following
regimen B compared with A. Attenuation in the veins were significantly lower in
regimen B than in regimen A with a maximum reduction of up to 84%
(p < 0.0001). With Regimen B, there were significant (p < 0.002) improvements
in AVCR at a variety of anatomical sites. The ROC analysis demonstrated a
significantly higher Az score for the novel protocol compared with Regimen A
(p < 0.05) with inter-reader agreement increasing from poor to excellent.
Conclusion
Significant improvements in visualisation of thoracic vasculature
can be achieved at the cervico-thoracic junction using a complex injection
contrast protocol.
B-0307 11:42
Dual-energy CT with reduced iodine load: a new option for standard
chest CTA in patients with superior vena cava syndrome
S. Bendaoud, O. Vanaerde, F. Molinari, A. Simeone, E. Algeri, J. Remy,
M. Remy-Jardin; Lille/FR (
[email protected])
Purpose: To evaluate the possibilities of dual-energy CT in the context of
superior vena cava syndrome (SVCS).
Methods
and Materials: 41 patients underwent a dual-source, dual-energy CT
angiographic examination with administration of a low-concentrated contrast
agent (160 mg iodine /mL) and reconstruction of 3 series of images (i.e., the 2
polychromatic series acquired at 80 and 140 kV; the fused images from both
tubes, equivalent to images acquired at 120 kV). The following parameters
were analysed: (a) the CNR and SNR within the SVC, pulmonary arteries and
aorta; (b) the presence of streak artifacts at the level of 3 nodal stations (i.e.,
2R, 4R, 10R).
S202
BA C D E F G
Friday
Results
Fused images provided (a) good to excellent opacification within the
SVC (n=40; 98%) without artifacts at the level of 2R (n=26; 63%), 4R (n=40;
98%) and 10 R (n=41; 100%); (b) analyzability of pulmonary arteries down to
the subsegmental level (n=31; 76%); and (c) good to excellent opacification of
the aorta (n=35; 85%). In 29 patients (29/41; 71%), averaged images alone
provided optimal evaluation of all vascular compartments; in 12 patients
(12/41; 29%), they had to be completed by images at 140 kV (n=6) to suppress
artifacts at the level of the nodal station 2R and/or images at 80 kV (n=10) to
improve the CNR at the level of subsegmental pulmonary arteries and/or the
aorta.
Conclusion
Dual-energy CT enables combination of optimal evaluation of
SVCS and diagnostic image quality at the level of the other thoracic
circulations.
B-0308 11:51
Impact of iterative reconstruction on CNR and SNR in a 256-slice MDCT
low-dose triple-rule-out angiography
B.M. Gramer, V. Phi van, M. Rasper, E.J. Rummeny, A. Huber; Munich/DE
Purpose: To evaluate the ability of a new iterative reconstruction algorithm
(IR), iDose4, for the improvement of quantitative image quality (IQ) in triple-rule-
out (TRO) angiography in emergency patients and to investigate the feasibility
of radiation dose reduction.
Methods
and Materials: ECG-gated 256-slice MDCT TRO angiography scans
were performed in 52 patients at 120 ± 0 kVp and 120 ± 0 mAs. Data were
reconstructed with a conventional standard filtered back projection (FBP) and
with seven different levels (L) of iterative reconstruction (IR (L1 - L7)). Image
noise, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were
evaluated for all data. In addition, the results of the emergency TRO-
examination were investigated.
Results
Noise was reduced from 34 ± 7 (FBP) to 16 ± 4 (IR Level 7). IR
improved SNR (34 ± 7.3 with FBP) up to 18.1 ± 15.9 (IR Level 7). Likewise,
CNR increased from 8.9 ± 0.5 (FBP) to 18.8 ± 2.47 (IR Level 7). With the TRO-
examination in 14 % it was found a pulmonary embolism, in 6 % a coronary
disease and in 2 % a aortic dissection.
Conclusion
IR improves SNR and CNR compared to FBP, thus a reduction of
30% radiation dose seems feasible. In futu re, several investigations concerning
the comparison between low-dose, high-dose protocols need to be further
evaluated.
10:30 - 12:00 Board Room B
Oncologic Imaging
SS 516
Trends in CT
Moderator
A. Gogbashian; Middlesex/UK
G. Petralia; Milan/IT
B-0309 10:30
Integrated metabolic-perfusion assessment of non-small cell lung cancer
using 18 F-FDG PET/CT and perfusion-CT
L. Calandriello, A. del Ciello, A. Larici, L. Leccisotti, A. Giordano, L. Bonomo;
Rome/IT (
[email protected])
Purpose: To assess the correlation between metabolic and perfusion
parameters in patients with non-small-cell lung cancer (NSCLC) who
underwent 18 F-FDG-PET/CT and perfusion-CT.
Methods
and Materials: 20 patients with clinically resectable (stage Ia-IIIa)
NSCLC underwent PET/CT and whole-tumor perfusion-CT within 2 weeks
before surgery. Peak standardised uptake value (SUVpeak), SUVmean and
metabolic tumor volume (MTV) calculated using manual (mMTV) and
automated (aMTV) contouring method with a threshold of 40% of the maximum
SUV, were used as metabolic parameters. Blood Flow (BF) was determined as
perfusion parameter. Patients were divided into two subgroups according to
maximum lesion diameter (30 mm or > 30 mm). We assessed the correlation
between perfusion and metabolic parameters in overall population and within
each subgroup. The difference of each parameter within subgroups was
calculated. Pearson coefficient and Mann-Whitney test were used for statistical
analysis; a p-value 0.05 was considered significant.
Results
No correlation was found between perfusion and metabolic
parameters in overall population. After dividing Patients into two groups, a
statistically significant negative correl ation was found between volumetric
metabolic parameters mMTV/aMTV and BF in Patients with tumor maximum
diameter > 30 mm (p:0.04 for both). A significant difference of BF, SUVpeak,
SUVmean, aMTV and mMTV was found between subgroups
(p:0.001;p:0.04;p:0.02;p:0.001;p:0.001): in bigger lesions BF tends to decrease
while metabolic parameters tend to increase.
Conclusion
Volumetric metabolic parameters correlate with perfusion
parameters depending on tumor size. PET/CT and Perfusion-CT parameters
cannot be considered equivalent in the assessment of NSCLC but their
combined evaluation can provide a better tumor characterisation with possible
future application.
B-0310 10:39
CT perfusion parameters as a prognostic biomarker in patients with non-
small-cell lung cancer
L. Calandriello, A. Larici, M. Occhipinti, A. Infante, G. Petrone, L. Bonomo;
Rome/IT (
[email protected])
Purpose: To correlate CT perfusion parameters with histopathological
prognostic factors in Patients with clinically operable early stage (Ia - IIIa)
NSCLC and to assess the correlation between these parameters and
recurrence in our study population
Methods
and Materials: 25 patients with clinically resectable NSCLC
underwent perfusion CT examination using 64 row CT and contrast medium
injection (50 ml, @ 5 ml/sec) before surgery. CT perfusion parameters
considered were: Blood Flow (BF) and Blood Volume (BV). Maximum tumor
diameter was also measured. Histopathological factors assessed were: tumor
stage and grade, extent of necrosis ( 10% or > 10%) and microvessels density
(MVD). After surgery Patients underwent clinico-radiological follow-up. Pearson
correlation, Anova test, T Student test and Chi-squared test were used for
statistical analysis. A p value < 0.05 was considered significant
Results
BF values were correlated with pathological stage (p:0.008). BF and
BV values were statistically lower in tumors with maximum diameter > 3 cm
(p:0.001; p:0.05) and with necrosis > 10%(p:0.01; p:0.05). In addiction BV
values were statistically associated with MVD (p:0.04). No correlation was
found between perfusion parameters and tumor grading. Mean follow-up was
15 months with recurrence disease occurred in 7 Patients. Pathological stage
(p:0.04), maximum tumor diameter (p:0.01) and BF values (p:0.05) were
significantly associated with the risk of recurrence
Conclusion
Perfusion parameters in Pts with early stage (IIa-IIIa) clinically
operable NSCLC correlate with hist opathological prognostic factors and may
serve as pre-treatment prognostic biomarker of risk of recurrence
B-0311 10:48
Clinical application of dual-phase C-arm CT with a single injection to
detect hepatocellular carcinoma and metastasis during hepatic
arteriography
J. Wang
1, K.-Y. Huang1, Z.-G. Zhuang1, J.-C. Chi1, J.-J. Cheng1, J. Beilner1,
Y. Deuerling-Zheng2; 1Shanghai/CN, 2Forchheim/DE
Purpose: To investigate the feasibility of using existing 3D-DSA acquisition to
perform dual-phase C-arm CT with a single contrast injection for the detection
of tumour lesions and blood supply during TACE.
Methods
and Materials: 10 cases were collected from July 2012 to May 2013,
who received dual phase C-arm CT (Artis Zeego, Siemens, Germany) during
TACE. We injected 48 ml (diluted to 33%) contrast media at a rate of 4 ml/s
through a 5 F catheter placed in the celiac trunk, manually triggered 3D-DSA
scan protocol was used to obtain arterial and portal venous phase images.
First run was initiated 2 seconds after contrast media injection. Second run
was triggered 2 seconds after the C-arm rotates back to initial position. CT-like
images in sagittal, transversal and coronal orientation were reconstructed
using 10 mm-thick maximal intensity projection (MIP) to visualise small vessels
and lesions.
Results
Out of the 10 cases, image quality of 2 cases found to be insufficient
for diagnosis due to metal and motion art efacts. 50% (5 of 10 patients) lesions
were found in both phases; 20% more lesions were detected in portal venous
phase and 10% more in arterial phase. Ring-enhancement could be seen for
metastases in venous phase.
Conclusion
Application of intra-procedural dual-phase C-arm CT for TACE
could visualise hepatic lesions more clearly at least in one phase. It could
potentially offer a more accurate real-time planning for super-selective
embolisation. Moreover, sequential TACE and portal vein embolisation could
be considered in cases lesions were only detected in portal venous phase.
Author Disclosures:
K. Huang: Consultant; Siemens. J. Beilner: Consultant; Siemens. Y.
Deuerling-Zheng: Consultant; Siemens.
S203
BA C D E F G
Friday
B-0312 10:57
Selection of colon cancer patients for neoadjuvant chemotherapy by
preoperative CT
A. Nørgaard, C. Dam, S.R. Rafaelsen; Vejle/DK
(
[email protected])
Purpose: Preoperative staging is essenti al to plan correct treatment of colon
cancer and calls for objective, accurate methods with sufficient reproducibility.
This is a prerequisite for the introduction of neoadjuvant chemotherapy, which
represents a new treatment option. The aim was evaluate the diagnostic
accuracy of multislice computed tomography (CT) in local staging of colon
cancer correlated with histopathological parameters, including criteria for
adjuvant chemotherapy.
Methods
and Materials: A total of 74 patients were included. All had
preoperative CT scans and surgical resection of their colon tumours. Tumour
stage (T-stage), extramural tumour invasion (ETI), nodal stage (N-stage),
extramural venous invasion (EVI), and the distance from tumour to nearest
retroperitoneal fascia (DRF) were assessed on the CT scan and compared
blindly with the results of the patholog ical examination, which also included
evaluation of the criteria for adjuvant chemotherapy. Advanced tumours were
defined as T3 with ETI 5 mm or T4.
Results
Sixty-nine percent of the tumours were correctly T-staged by CT, 7%
were overstaged and 24% were understaged. As to correct recognition of ETI
on the CT scan, the observer was 70% accurate compared with histopathology
(sensitivity 64%; specificity 78%). N-stage, EVI, and DRF had poor accuracy:
53%; 55% and 63%. All patients with advanced tumours on CT fulfilled the
criteria for adjuvant chemotherapy. PV+ value: 100% (95% CI: 88.0-100).
Conclusion
CT has a potential as the imaging modality of choice in the
preoperative selection of advanced tumours suitable for neoadjuvant
chemotherapy. This can be done without overtreatment of low-risk patients.
B-0313 11:06
Vertebral marrow enhancement in chest MDCT studies of oncology
patients without superior vena cava obstruction
A.J. Villanueva Marcos
1, M. Paramo1, R. Zalazar1, P. García-Barquín1,
J. Etxano1, J. Larrache1, G. Bastarrika2, J. Pueyo1; 1Pamplona/ES, 2Toronto,
ON/CA (
[email protected])
Purpose: VM is a transient contrast vertebral opacification that may be
mistaken for metastases in oncology patients with SVC obstruction. Our aim
was to demonstrate that VM can be found in patients with thoracic venous
collateral vessels (VC) without SVC obstruction.
Methods
and Materials: Chest MDCT exams of 56 patients with VC without
VCS obstruction were evaluated. Two groups based on the presence of VC
due to venous thrombosis (VT) at the brachiocephalic and/or subclavian and
axillary veins (group 1, n=28) or due to anatomical compression of the
subclavian vein, without VT (group 2, n=28) were formed. MDCT exams were
performed with arms in upright position, af ter injection of 100 ml of Iohexol at
2 ml/s in the arm with VT/compression. VC was classified in shoulder,
mediastinal, anterior chest wall, neck and posterior paravertebral according
their distribution. One point was assigned for each anatomical area. Intensity of
VC was defined by the summation of these points. Images were compared with
a normal follow MDCT of the same patient. Fisher's test and Chi square of
Pearson test were performed.
Results
Nine patients of group 1 showed 49 VM, whereas no patient of group
2 had VM (p= 0.002). Patients with VM had VC in posterior paravertebral
areas, mediastinum or neck more frequently than those without VM (p=0.005,
p=0.000, p=0.017). 66.6 % of patients with VM presented 3 or more VC
intensity points, whereas 19.14% of patients without VM showed that intensity
(p=0.008).
Conclusion
VM was found only in oncology patients with VC and VT of the
brachiocephalic and/or subclavian-axillary veins without VCS obstruction.
B-0314 11:15
Dual source dual-energy CT in patients with advanced gastrointestinal
stromal tumour: image quality and accuracy of hepatic metastasis
detection with virtual monoenergetic imaging
S. Sudarski
1, P. Apfaltrer1, J.W. Nance2, M. Meyer1, C. Fink3, S.O. Schönberg1,
T. Henzler1; 1Mannheim/DE, 2Baltimore, MD/US,
3Celle/DE (
[email protected])
Purpose: To compare in dual-energy CT (DECT) conventionally reconstructed
polyenergetic images (PEI) at 120 peak kilovoltage (kVp) to virtual
monoenergetic images (MEI) at different kiloelectron volt (keV) levels for
evaluation of gastrointestinal stromal tumor (GIST) hepatic metastases with
regard to objective (IQob) as well as subjective (IQsub) image quality and
diagnostic accuracy in metastasis detection assessed by readers of varying
experience.
Methods
and Materials: From 50 examinations of 17 GIST patients
undergoing abdominal dual-source DECT for staging and follow-up, PEI and 9
MEI in 10-keV intervals from 40-120 keV were reconstructed. Liver contrast-to-
noise ratios (CNR) and metastasis-to-liver ratios were calculated. MEI
reconstructions with the highest IQob were compared to PEI for IQsub and
diagnostic accuracy by one experienced (ER) and one inexperienced reader
(IR).
Results
MEI at 70 keV had highest IQob with equal liver CNR and metastasis-
to-liver ratio compared to PEI. The ER rated 70 keV MEI and PEI equally high
(median 4), whereas the IR rated IQsub best in 70 keV MEI (median 5).
Diagnostic accuracy was equal in 70 keV MEI and PEI for ER (AUC= 1.00) and
better in 70 keV MEI than in PEI for IR (AUC= 0.98 and 0.96, p > 0.05).
Conclusion
MEI at 70 keV provided an IQob equivalent to PEI. Regarding the
IR, IQsub was impoved in 70 keV MEI compared to PEI and a tendency
towards higher diagnostic accuracy was seen. Therefore, inexperienced
readers might improve their diagnostic confidence in the detection of hepatic
GIST metastases by evaluating MEI reconstructions at 70keV.
B-0315 11:24
Iterative reconstructions safire applied to dual-energy CT images for
increasing detectability of small low-contrast hypoattenuating liver
metastases
E. Faietti, L. Berta, L. Mascaro, M. Ravanelli, R. Maroldi; Brescia/IT
(
[email protected])
Purpose: To optimise DECT protocols with Sinogram Affirmed Iterative
Reconstruction (SAFIRE) algorithms in order to improve detection of small
hypodense liver metastases.
Methods
and Materials: A DECT portal-phase acquisition of two healthy livers
was reconstructed using standard filtered-back-projection (FBP) and four
SAFIRE reconstruction schemes obtained by combining two iterative medium-
smooth filters (I26,I30) and two different strengths (S3,S5). SAFIRE
reconstructions were performed on both whole-dose (DE-composition 0.5) and
half-dose 80 kVp images, while FBP reconstructions were applied to DE-
composition images only, resulting in 9 reconstructions per patient. Eight 6-mm
spherical lesions were simulated in random positions for each series, resulting
in 144 simulated lesions. A -26 HU lesion-to-liver contrast (LLC) was selected
for DE-composition images and a -33.8 HU for 80 kVp images, according to
the results of a preliminary study on 29 colorectal cancer liver metastases
demonstrating a 30% increased LLC in 80 kVp images compared to DE-
composition. Four expert radiologists performed a detectability test and rated
the overall quality, noise and sharpness (5-point scale) in all images.
Results
FBP reconstructions allowed only 13% lesions to be detected. Best
performance was obtained with S5 reconstructions on DE-composition series
(47% and 61% lesions detected with I26 and I30 kernels, respectively). 80 kVp
series provided worse performances compared to DE-composition series.
Contrary to expectations within DE-composition series, S5 image quality
ratings proved to be worse than S3 and FBP, while 80 kVp series resulted the
worst in all.
Conclusion
SAFIRE has the potential to increase sensitivity for small low-
contrast hypodense liver lesions.
B-0316 11:33
Assessment of early treatment effects of targeted tumour therapy by CT:
systematic comparison of dual-energy CT, conventional contrast-
enhanced CT and dynamic contrast-enhanced CT
G. Jost, G. Knobloch, A. Huppertz, H. Pietsch;
Berlin/DE (
[email protected])
Purpose: Comparison of dual-energy computed tomography (DE-CT),
dynamic contrast-enhanced CT (DCE-CT) and conventional contrast-enhanced
CT (CE-CT) in the assessment of early treatment response after targeted
tumor therapy in a preclinical setting.
Methods
and Materials: A rat GS9L glioma model was examined with
contrast-enhanced dynamic DE-CT measurements (dual source CT,
80 kV/140 kV) before and on days 1 and 4 after start of daily regorafenib (n=8)
or placebo (n=8)treatment. Based on that DE-CT (60s p.i., 80/140 kV) derived
iodine maps and the DCE-CT (0-30s p.i., 80 kV) based parameters maps for
blood flow (BF), blood volume (BV), and vascular permeability (PMB) were
calculated and compared to conventional CE-CT (60s p.i., 80 kV).
Results
The regorafenib group exhibited a significantly lower tumor iodine
concentration and a significantly lower PMB in the tumor on day 1 and 4
compared to baseline, which was not observed for the placebo group. CE-CT
showed a significant decrease in tumor density on day 4 but not on day 1. The
DE-CT derived iodine concentrations correlated well with CE-CT tumor
attenuation and PMB but not with BV or BF.
S204
BA C D E F G
Friday
Conclusion
DE-CT derived tumor iodine concentrations allow an early
treatment monitoring of targeted tumor therapy in good agreement with the
DCE-CT parameter PMB. Both methods DE-CT and DCE-CT showed a
superior performance compared to single energy CE-CT based measurement
of tumor attenuations.
Author Disclosures:
G. Jost: Employee; Bayer AG. A. Huppertz: Employee; Siemens AG. H.
Pietsch: Employee; Bayer AG.
B-0317 11:42
4th generation iterative reconstruction algorithm in low dose whole-body
CT in comparison with standard dose examination for follow-up of
oncologic patients
A. Casiraghi, D. Ippolito, P.A. Bonaffini, C. R.G.L. Talei Franzesi, D. Fior,
S. Sironi; Monza/IT (
[email protected])
Purpose: To compare radiation dose and image quality of low dose protocol
with iterative reconstruction algorithm (iDose4) with standard dose protocol CT
examination for follow-up of oncologic patients.
Methods
and Materials: 51 patients (32 male; mean age 69.5 ±10.5 years,
mean BMI 24.9 ±4.1) with malignant disease underwent, during follow-up, low-
dose whole-body CT scan in a single venous phase (256-row CT, Brilliance,
Philips, iDose4 modulation) with the following parameters: 120 kV, variable
mAs (with dose modulation), slice thickness 2 mm. The patients underwent
also standard dose examination on 16-rows CT scan (Philips), with 120 kV,
200-400 mAs (depending on patient weight), slice thickness 2 mm. Image
noise, sharpness and diagnostic quality were evaluated using a 4-point scale.
Dose-length product (DLP) was calculated and data from both examinations
were compared and statistically analysed.
Results
Total DLP was significantly (p < 0.001) lower in low-dose
examinations as compared to standard-dose CT studies
(1010.0±375.1 mGy*cm vs 1404.9 ±281.6), with an overall dose reduction of
29%. Density values in liver and vessels were higher in low-dose images (liver
111.7±17.2 HU vs 101.7± 16.6; aorta 164.8± 17.8 vs 149.6 ±22.7, p < 0.001).
Qualitative analysis didn't reveal significant difference in image noise and
diagnostic quality of the two groups.
Conclusion
iDose4 reconstruction algorithm allows significant reduction
(29%) of radiation dose without loss of diagnostic quality representing an
useful technique to reduce dose exposure in oncologic patients.
B-0318 11:51
Filtered back projection vs adaptive statistical iterative reconstruction in
staging-CT: comparison of dose and image quality in NET-patients
G. Böning, M.-L. Schäfer, U. Grupp, J. Kahn, D. Renz, T. Denecke, B. Hamm,
M. Pavel, F. Streitparth; Berlin/DE (
[email protected])
Purpose: The purpose of this study was to investigate, if dose reduction via
adaptive statistical iterative reconstruction (ASIR) affects image quality and
diagnostic evidence in patients with neuroendocrine tumour (NET).
Methods
and Materials: This prospective, single-center study was performed
with a 64-section CT-scanner (LightSpeed VCT; GE Healthcare), updated with
ASIR technology. 16 patients with histologically proven NET underwent
staging-CT (thorax and abdomen) with filtered back projection (FBP) (protocol
A) and with ASIR 40% (protocol B) in follow-up, by using identical scan
parameters. To evaluate image quality, SNR and CNRs were calculated. In
addition, subjective 5-grade scoring (1 insufficient to 5 excellent) was
performed by two experienced and blinded readers.
Results
Our results show that, with matched scan length (596± 75 mm [A],
609±38 mm [B]), protocol B reduced the DLP by 35.7%
(1053.1±404.8 mGy*cm [A], 676.9 ±248.5 mGy*cm [B]). Protocol B increased
SNR (9.8±2.7 [A], 12.9 ±4.5 [B]) and CNR (complete tumor-to-liver, 3.2± 2.1 [A],
4.3±2.7 [B]). There were no significant differences in subjective image quality
scoring: noise (4.2 ±0.8 [A], 4.0 ±0.8 [B]), contrast (4.4 ±0.7 [A], 4.1 ±0.8 [B]),
visibility of small structures (4.4 ±0.7 [A], 4.2±0.8 [B]), visibility of suspect lesion
(4.8±0.4 [A], 4.8 ±0.4 [B]), artefacts (5.0 ±0 [A], 5.0 ±0 [B]) and diagnostic
confidence (5.0±0 [A], 5.0±0 [B]).
Conclusion
In clinical practice, ASIR can be used to reduce radiation dose
without decreasing objective image quality and diagnostic confidence in NET-
patients.
10:30 - 12:00 Room E1
Musculoskeletal
SS 510
Spine: osteoporosis, malignancy and
spondylarthropathy
Moderators:
M.P. Aparisi Gomez; Valencia/ES
C. Van Kuijk; Amsterdam/NL
B-0319 10:30
Automatic detection of osteoporotic vertebral fractures in routine
thoracic and abdominal MDCT
T. Baum1, J.S. Bauer1, T. Netsch2, T. Klinder2, M. Dobritz1, E.J. Rummeny1,
P.B. Noël1, C. Lorenz2; 1Munich/DE, 2Hamburg/DE (
[email protected])
Purpose: To develop an automatic spine segmentation algorithm for routine
thoracic and abdominal MDCT and use this algorithm to automatically detect
osteoporotic vertebral fractures.
Methods
and Materials: We retrospectively identified patients older than 45
years of age, who underwent routine contrast-enhanced thoracic and
abdominal MDCT. Cross-sectional M DCT images of 71 patients including 8
men and 9 women with osteoporotic vertebral fractures were selected to
investigate the performance of our automa tic spine segmentation algorithm to
detect these fractures. Furthermore, the algorithm was applied to baseline and
follow-up MDCT images of 9 patients (4 men and 5 women) with incidental
vertebral fractures in the follow-up MDCT. The algorithm localised and
identified the vertebrae T5-L5. Each ve rtebra was automatically segmented by
using corresponding vertebrae surface shape models that were adapted to the
original images. Anterior, middle, and posterior height of each vertebra was
automatically determined, and anterior-posterior-ratio (APR) and middle-
posterior-ratio (MPR) were computed. As gold standard, two radiologists
graded vertebral fractures from T5 to L5 according to the Genant classification
in consensus by using the sagittal reformations.
Results
Using ROC analysis to differentiate vertebrae without versus with
prevalent fracture, AUC values of 0.84 and 0.83 were obtained for APR and
MPR, respectively (p < 0.001). The longitudinal changes in APR and MPR
were significantly different between vertebrae without versus with incidental
fracture ( ,APR: -8.5% ±8.6% versus -1.6% ±4.2%, p=0.002; , MPR: -
11.4%±7.7% versus -1.2%±1.6%, p < 0.001).
Conclusion
The presented algorithm may support radiologists to report
currently underdiagnosed osteoporotic vertebral fractures, so that appropriate
therapy can be initiated.
Author Disclosures:
J.S. Bauer: Research/Grant Support; Deutsche Forschungsgemeinschaft
(DFG BA 4085/1-2). T. Netsch: Employee; Philips. T. Klinder: Employee;
Philips. C. Lorenz: Employee; Philips.
B-0320 10:39
Pitfalls in previous dual energy x-ray absorptiometry scans: adherence to
International Society of Clinical Densitomery 2007 guideline
C. Messina1, M. Bandirali1, L.M. Sconfienza1, R. Spairani1, F. Ulivieri2,
F. Sardanelli1; 1San Donato Milanese/IT, 2Milan/IT (
[email protected])
Purpose: Dual-energy X-ray absorptiometry (DXA) is the standard of care for
diagnosing osteoporosis and monitoring patients. Inaccurate DXA exams may
lead to different mistakes (known as "pitfalls") resulting in erroneous data
interpretation and equivocal reports. We evaluated rate and type of errors in
previous DXA of patients coming to our institution for a new DXA exam.
Methods
and Materials: We prospectively evaluated 2,476 patients who
presented at our institution to perform DXA. We excluded patients without
previous DXA and those who performed the previous examination at our
institution. Two radiologists with 4 ye ars of experience in DXA re-evaluated
previous DXA of 498 patients (38 males, 447 females; mean age 68 ±9 years),
according to International Society of Clinical Densitometry (ISCD) 2007
guidelines. Errors were classified in four categories: patient-positioning (PP),
data-analysis (DA), artefacts, demographics. When available, previous
comparisons among outsource DXA were analysed also for technical errors.
Results
Previous outsource DXA were performed at 37 different centers, with
13±8 patients (mean ± standard deviation) per center. Out of 485 DXA, 451
(93%) had at least one error for a total of 558 errors: 441 (79%) were DA, 66
(12%) PP, 39 (7%) artefacts, and 12 (2%) demographics. Only 42 (9%) had a
previous DXA for comparisons, for a total of 57 errors: 31 (54%) were DA, 17
(30%) PP, and 9 (16%) scan mode discrepancies.
Conclusion
More than 90% of previous DXA presented at least one error.
ISCD guidelines are very poorly adopted.
S205
BA C D E F G
Friday
B-0321 10:48
Early detection of sacroiliitis using DW imaging
L. Miu; Timisoara/RO (
[email protected])
Purpose: This study proposed to evaluate the value of diffusion-weighted MRI
to detect active inflammatory changes in the sacroiliac joints of patients with
early axial spondyloarthritis.
Methods
and Materials: 36 patients with chronic low back pain underwent
clinical and MRI evaluation for axia l spondyloarthritis or early ankylosing
spondylitis. STIR, contrast-enhanced T1-weighted, fat-saturated T2-weighted,
and diffusion-weighted b value1,000 s/mm 2 images were obtained. The
presence of subchondral bone marrow oedema, subchondral fatty marrow
infiltration, or contrast enhancement in the sacroiliac joints or adjacent
enthesitis sites was considered a marker for active inflammatory changes. All
MRI sequences were evaluated for the presence of acute inflammatory
changes. Mean apparent diffusion coeffici ent values of diffusion-weighted
images were calculated from normal and involved iliac and sacral bones of
sacroiliac joints.
Results
ADC values measured from the lesions at b value of 1,000 s/mm2 in
patients with sacroiliitis n = 13 were signi ficantly higher than values measured
from iliac and sacral bones in patients with low back pain of mechanical origin
n = 29. DWI showed sensitivity for detecting acute lesions in early sacroiliitis
similar to that of T1-weighted gadolinium images 89.3%DWI vs 91.3%T1+c.
Conclusion
DWI is a sensitive, fast sequence and does not require a contrast
agent, which makes it a good and cost-effective alternative for imaging
sacroiliac joints. DWI also offers the possibility of quantifying diffusion
coefficients of the lesions, which helps to discriminate between normal and
involved subchondral bone.
B-0322 10:57
Effects of recent lung transplantation on cortical and trabecular
microarchitecture and bone strength in men and women
L. Fischer, A. Valentinitsch, M.D. DiFranco, C. Schueller-Weidekamm,
D. Kienzl, T. Gross, F. Kainberger, G. Langs, J.M. Patsch; Vienna/AT
(
[email protected])
Purpose: Organ transplant recipients often suffer from severely impaired bone
strength arising of pre-existing osteoporosis and bone disease aggravation due
to immunosuppressive treatment after surgery. Lung transplant recipients are
under an intense post-transplant drug regimen and fracture rates are high.
Despite, low bone mineral density and altered states of bone turnover have
been reported, bone microarchitecture status has been scarcely analysed.
Methods
and Materials: After recovery from surgery, 61 patients (female:
n=31, male: n=30; mean age: 45.9± 14.9), and 60 healthy, age and gender-
matched controls (Co) underwent high resolution peripheral quantitative
computed tomography (HR-pQCT; SCANCO Medical AG) of the ultradistal
radius. Volumetric bone mineral density, trabecular and cortical bone
microarchitecture and bone strength were assessed. ANCOVA was used to
compare mean differences between female and male LuTX patients and Co.
Results
Female transplant recipients exhibited larger and more
heterogeneous cortical pores (+13.3%, p=0.009; +16.7%, p=0.029), greater
trabecular heterogeneity (+80%, p=0.044) and lower mid-trabecular BMD (-
17.9%, p=0.049) than healthy women. Male transplantation recipients had
lower cortical area (-21.3%, p=0.001), global BMD (-19.5%, p=0.002),
trabecular BMD (-22.2%, p=0.003), BV/TV (-23%, p=0.002), trabecular number
(-13%, p=0.006), trabecular thickness (-12.5%, p=0.023), stiffness (-21%,
p=0.001), failure force (-21%, p < 0.001), overall bone strength (-24%,
p < 0.001) and larger trabecular separation and network heterogeneity
(+25.6%, p=0.015; (+50%, p=0.036) than healthy men.
Conclusion
Male and female patients with recent lung transplantation exhibit
relevant deficits in trabecular and cortical bone quality and bone strength.
Furthermore, they exhibited major disturbances in gender-specific bone
characteristics.
B-0323 11:06
Bone microarchitecture in thalassaemia
J. Yamamura1, R. Grosse1, B. Schönnagel1, S. Keller1, C. Berliner1,
P. Nielsen1, G. Adam1, R. Fischer2; 1Hamburg/DE, 2Oakland, CA/US
(
[email protected])
Purpose: To assess the microarchitecture of the bone density of patients with
thalassaemia using HR-pQCT and compared to DXA.
Methods
and Materials: In 17 patients with beta-thalassaemia major (n=10), -
intermedia (n=6), and CDA-II (n=1), the bone marrow density (BMD) of lumbar
spine (LS) and total hip was measured by DXA. BMD Z-scores were
calculated; volumetric BMD and the trabecular architecture of the non-
dominant distal radius and tibia by HR-pQCT were assessed. Liver iron
concentration and endocrinological parameters were determined. Non-
parametric statistical analysis was used.
Results
In 15 patients, low BMD values (LS Z-score range: -1.1 to -3.1)
measured by DXA were significantly correlated with total volumetric density
(p=0.002) measured by HR-pQCT at the distal radius. In 6 patients with latent
hypogonadism, the trabecular inhomogeneity parameter at the distal radius
deviated by more than 100% from the upper normal value. Patients with
hypogonadism (n=9) were significantly different from normals with respect to
radial TbSp SD (p=0.02), but not to LS Z-score. Patients with fractures (n=5)
had lower total densities (p=0.02) and trabecular TbSp SD (p=0.02) at the tibia
and started blood transfusions (Tx-age) at a higher age (p=0.023). Z-scores did
not reflect the fracture risk in this patient group (p=0.11). Only the trabecular
thickness of the tibia seems to be correlated with the Tx-age (Rs=0.62,
p=0.007). Liver iron was mainly correlated with tibial TbSp SD (Rs=0.54,
p=0.025).
Conclusion
In thalassaemia, BMD Z-scores seem to underestimate fracture
risk because a normal cortical thickness and density may conceal a porous
trabecular structure.
B-0324 11:15
Durie-Salmon plus vs international staging system: the impact of MRI in
the staging of multiple mieloma
G. Filonzi, P. Spinnato, E. Salizzoni, G. Battista, U. Albisinni, A. Bazzocchi;
Bologna/IT (
[email protected])
Purpose: The Durie Salmon Plus (DDS+) is a recently developed staging
system for Multiple Myeloma (MM), based on the number of bone lesions
detected with MRI or FDG PET/CT and on few clinical parameters. Given that
the DSS+ has not been validated yet, the aim of our study is to compare the
International Staging System (ISS), a widely used system for MM that
evaluates only laboratory parameters, with the DSS+, according to patients'
survival rates and response to therapy.
Methods
and Materials: We retrospectively enrolled 52 patients, diagnosed
with MM during 2004-2008, who underwent contrast-enhanced MRI (1.5 T)in
our department at the time of diagnosis. Patients were staged with both ISS
and DSS+ and the two systems were then compared according to survival rate,
response to therapy and disease-free survival (Student's-T test, COX and
Kaplan-Meier analysis), during a 5-year follow-up.
Results
From ISS to DSS+ 22 patients have been upstaged, 11 have been
downstaged and 19 have been staged the same. After therapy 40/52 patients
(76.9%) achieved a complete response, with a mean free-disease survival of
49.5 months. During the follow-up 4/52 patients (7.7%) have died; according to
DSS+ all these 4 patients were at stage III, only one according to ISS. No
statistically significant difference was found between the two staging system
considering response to therapy.
Conclusion
Our data indicate that DSS+ has a great potential in staging MM
patients, for survival and therapy efficacy prediction. To our knowledge, this is
the first study designed to compare these two staging systems.
B-0325 11:24
Association of osteolyses with vertebral fractures in patients with
multiple myeloma
J. Borggrefe1, S. Giravent2, J. Pena1, A. Wulff2, M. Heller2, C.C. Glüer2;
1Cologne/DE, 2Kiel/DE (
[email protected])
Purpose: In patients with multiple myeloma (MM), computed tomography is
widely used for staging and to detect fractures. We investigated the association
of prevalent vertebral fractures in MM patients with clinical and radiological
features of the disease.
Methods
and Materials: 128 MM patients underwent whole body low-dose CT
in clinical routine with 1.5-mm slice thickness, 120 kVp and approximately
100 mAs. Two radiologists reported on following parameters based on
predefined criteria: vertebral fractures, general fracture risk, osteopenia,
trabecular sclerosis, extramedullary MM manifestations, osteolyses up to a size
of 8 mm and larger than 8 mm. Age-adjusted multivariate logistic regression
models were calculated to describe the association of these parameters with
prevalent fractures.
Results
The prevalence of vertebral fractures was 49%. Patients with
fractures were comparable in age to patients without fractures (63 vs 64 years
of average, p > 0.6). In age-adjusted logistic regression, the OR for prevalent
vertebral fractures in women showed the strongest association to the
prevalence of osteolytic lesions, regardless of size. In both women and men,
patients with larger osteolyses did not show a higher prevalence of fractures. In
men, the osteopenia showed the strongest association to fracture risk with an
OR of 2.8 (1.6 -4.7). Suspected fracture risk was associated to fractures with
an OR of 2.3 (1.6 - 3.8).
Conclusion
The prevalence of vertebral fractures in myeloma patients is
associated with osteopenia and osteolytic changes. Prevalence of larger
osteolyses did not show a higher association to fractures than patients with
smaller osteolytic changes.
S206
BA C D E F G
Friday
B-0326 11:33
Determination of the best combination of b-values for ADC-based
assessment of benign and malignant vertebral body fractures with a
diffusion-weighted ssTSE sequence
T. Geith, G. Schmidt, A. Biffar, O. Dietrich, H.-R. Dürr, M.F. Reiser,
A. Baur-Melnyk; Munich/DE (
[email protected])
Purpose: Finding the best combination of b-values for apparent-diffusion-
coefficient (ADC)-based assessment of acute benign and malignant vertebral
body fractures using a ssTSE-sequence.
Methods
and Materials: 26 acute benign (mean age 69, 31.5-86.2 years) and
20 malignant vertebral fractures (mean age 63.4, 24.7-86.4 years). Standard
morphological sequences and a diffusion- weighted (DW) single-shot turbo spin
echo (ssTSE) sequence at different b-values (100, 250, 400, 600 s/mm²) were
acquired at 1.5 T. ADCs were determined based on regions of interest (ROIs),
manually adapted to hyperintense areas on STIR in the fractured vertebral
bodies. Combinations of two to four b-values were used to calculate the ADC,
using a least-squares algorithm. Statistically significant differences were
determined with the Student's t-test and Mann-Whitney-U test. ROC analysis
and the Youden-index were used to determine cut-off values with the highest
sensitivity and specificity.
Results
Benign fractures had significantly higher ADCs than malignant
fractures (except for the combination of b=400 s/mm
2 and b=600 s/mm 2).
Higher b-values resulted in lower ADCs than calculated with low b-values.
ADCs calculated with b=100 and 400 s/mm 2 had the highest AUC (0.85). The
second highest AUC (0.829) showed the ADCs calculated with b=100, 250,
and 400 s/mm 2. The Youden-index with equal weight given to sensitivity and
specificity suggests to use an ADC calculated with b=100, 250, and 400 s/mm 2
(cut-off ADC< 1.7 ×10-3 mm2/s) to best diagnose malignancy (sensitivity=85%,
specificity=84.6%).
Conclusion
The combination of low to intermediate b-values
(b=100,250,400s/mm2) provides the best diagnostic capability for ADC-based
differentiation of acute benign and mali gnant vertebral body fractures using a
diffusion-weighted ssTSE sequence.
B-0327 11:42
Assessing structural changes in axial spondyloarthritis using a low-dose
biplanar imaging system (EOS)
A. Molto1, V. Freire1, A. Feydy1, W.P. Maksymowych2, M. Benhamou1,
F. Rannou1, M. Dougados1, L. Gossec1, J.-L. Drapé1; 1Paris/FR, 2Edmonton,
AB/CA (
[email protected])
Purpose: Patients with axial spondyloarthritis (SpA) experience repeated
spine imaging. EOS is a new low-dose imaging system with significantly lower
irradiation than conventional radiography (CR). The objective was to explore
the EOS performances compared to CR, for the classification and follow-up of
SpA.
Methods
and Materials: Observational prospective single-center study,
including SpA patients (definite diag nosis by expert opinion) and control
patients [definite chronic mechanical low back pain (cLBP)]. All patients
underwent pelvic and frontal and lateral CR of the entire spine, and 2D EOS
imaging on the same day. Images were blindly assessed for sacroiliitis
(modified New York criteria, mNY), and for ankylosis of the spine (modified
Stoke Ankylosing Spondylitis Spinal Score, mSASSS). Global ease of
interpretation was rated 0-10. The primary outcome was inter-modality
agreement, with an a priori defined non-inferiority limit of 0.7. Inter-observer,
intra-observer and inter-modality agreement were measured by kappa,
weighted kappa, intra-class correlation coefficient, and Bland-Altman plots.
Results
48 SpA patients [mean age 47.6 ± 14.9 years, symptom duration
21.4 ± 13.3 years, 35 (70%) men] and 48 cLBP controls (mean age 49.1 ± 10.7
years; 9 (22.5%) men] were included. Inter-modality agreement between EOS
and CR was 0.50 (0.26-0.75) and 0.97 (0.95-0.98), for sacroiliitis and
mSASSS, respectively. Ease of interpretation was greater for CR (8.2 ±0.9) as
compared to EOS (7.2±0.8, p < 0.0001).
Conclusion
Our results suggest that EOS could replace CR for the
classification and follow-up of the structur al damage of the spine, but its place
in the classification of sacroiliitis remains unclear.
B-0328 11:51
Reading of the sacroiliac joints on plain radiographs in undifferentiated
spondyloarthropathies: agreement between local reading and trained
central reading in a cohort of 708 patients
R. van den Berg
1, G. Lenczner2, A. Feydy2, D. van der Heijde1, M. Reijnierse1,
A. Saraux3, P. Claudepierre4; 1Leiden/NL, 2Paris/FR, 3Brest/FR, 4Créteil/FR
(
[email protected])
Purpose: In daily practice, local radiologists/rheumatologist judge sacroiliac
joints on X-rays (X-SI), while in cohorts the scoring is done by trained readers.
Our aim was to compare the local scores to centralised scores.
Methods
and Materials: Patients with back pain from the 25 participating
centers were included in the DESIR cohort ( n=708). Baseline X-SIs were
scored by the local reader, according to a scoring method derived from the
modified New York (mNY) criteria1 (local score). Grade 2 and 3 from the
original mNY were pooled together in one combined grade 'DESIR-2'.
Sacroiliitis was defined by at least unilateral grade DESIR-2. In addition, two
centralised readers independently scored all X-SIs according to the original
mNY criteria. In case of disagreement, a radiologist experienced in SpA
imaging served as adjudicator. An X-SI was marked positive for sacroiliitis if
2/3 readers agreed on bilateral mNY-2 or unilateral mNY-3.
Results
Inter-reader agreement between the two centralised readers was
moderate (Kappa 0.54), while percentage agreement (84.3%) was good.
However, the adjudicator needed to score 108/689 (15.7%) X-SIs because of
disagreement among the two centralised readers. Overall, more radiographs
were scored positive by the local readers ( n=184) than by the centralised
readers ( n=145). In 77 patients, the X-SI was scored positive by the local
reader but negative by the centralised readers.
Conclusion
Agreement between the centralised score and local score, also
the inter-reader agreement between the two centralised readers, was
moderate. The role of X-SI as diagnostic criterion for axial SpA should be re-
evaluated.
10:30 - 12:00 Room F2
Breast
SS 502
Tomosynthesis, digital mammography and
screening
Moderators:
L.A. Carbonaro; San Donato Milanese/IT
A. Evans; Dundee/UK
B-0329 10:30
Performance of one-view breast tomosynthesis versus two-view
mammography in breast cancer screening: first results from the the
Malmö breast tomosynthesis screening trial
S. Zackrisson, K. Lång, P. Timberg, I. Andersson; Malmö/SE
(
[email protected])
Purpose: The combination of 2-view BT and 2-view DM in breast cancer
screening has been evaluated in three recent studies. The Malmö Breast
Tomosynthesis Screening Trial (MBTST) was designed to assess the efficacy
of 1-view BT versus 2-view DM in breast cancer screening. We now report
preliminary results from the interim analysis of 7,500 screened women.
Methods
and Materials: MBTST is a prospective, single-armed, paired study
with a planned inclusion of 15,000 screening participants aged 40-74 years. In
addition to the regular screening mammogram a 1-view BT with reduced
compression is acquired with a Siemens Mammomat Inspiration unit. BT and
DM images are read independently with double reading. BI-RADS ratings of 1-
5 is reported and women with >= 3 are routinely recalled for work-up. Breast
cancer detection rate, recall rate and other performance indicators will be
presented.
Results
Sixty-five breast cancers were detected, 46 by both BT and DM, 18
only by BT and one only by DM. The detection rate with 1-view BT was
8.5/1000 women screened versus 6.3/1000 with 2-view DM. The recall rate
after arbitration was 2.2% with 2-view DM versus 3.3% with 1 view-BT. Further
refined data will be presented.
Conclusion
One-view BT alone increased breast cancer detection rate with
approximately 40%. Our preliminary results suggests that 1-view BT as a
single screening modality might be feasible.
Author Disclosures:
S. Zackrisson: Equipment Support Recipient; Siemens AG. Speaker;
Speaker's fees and travel support from Siemens AG, Germany. K. Lång:
Speaker; Speaker's fees and travel support from Siemens AG, Germany. P.
Timberg: None. I. Andersson: Speaker; Speaker's fees and travel support
from Siemens AG, Germany.
B-0330 10:39
Comparison of FFDM with DBT in a UK retrospective reading study
F.J. Gilbert1, L. Tucker1, S. Nagarajan1, P. Willsher1, S. Astley2, K.C. Young3,
S. Duffy4; 1Cambridge/UK, 2Manchester/UK, 3Guildford/UK, 4London/UK
(
[email protected])
Purpose: To compare digital breast tomosynthesis (DBT) with full field digital
mammography (FFDM) in the UK NHS Breast Screening Programme.
Methods
and Materials: Women recalled following screening were consented
to have additional DBT imaging at th e time of their assessment. We had DBT
and FFDM reading data on 1087 women whose final diagnosis was cancer,
S207
BA C D E F G
Friday
and 4514 whose final diagnosis was normal or benign. We had synthetic two-
dimensional image (2D) reading data on 1032 cancers and 4137 non-cancers.
Data was collected prospectively for each case. Histopathology from core
biopsy or surgical excision was used as the gold standard to confirm cancer.
The sensitivity and speci ficity of the different imaging combinations was
compared in a retrospective reading study. Each case was read three ways
(FFDM alone, FFDM with DBT and synthetic 2D image with DBT) by three
different experienced screen readers who were not from the site where the
case originated. Statistical analysis used McNemar methods.
Results
FFDM+ DBT showed a small but borderline significant (p=0.05)
improvement in sensitivity over FFDM alone- 88% (955/1087) vs 85%
(929/1087). FFDM+DBT showed substantially and significantly (p < 0.001)
greater specificity than FFDM alone- 67% (3045/4514) vs 55% (2474/4514).
No significant difference in sensitivity was noted for FFDM vs synthetic 2D plus
DBT (p=0.9), but there was a highly signi ficant difference in specificity- 67%
(2774/4137)for synthetic 2D plus DBT vs 55% (2270/4137) for FFDM alone.
Conclusion
Digital breast tomosynthesis in combination with FFDM confers a
substantial improvement in specificity, and may confer a small improvement in
sensitivity.
B-0331 10:48
Added value of one-view breast tomosynthesis combined with digital
mammography according to reader experience
I. Thomassin-Naggara, N. Perrot, S. Dechoux, J. Chopier, C. De Bazelaire;
Paris/FR (
[email protected])
Purpose: To retrospectively evaluate the added value of one-view breast
tomosynthesis when combined with mammography to characterise breast
lesions.
Methods
and Materials: One hundred fifty-five women (mean age, 51.3 years,
range: 24-92 years) who systematically underwent mammography and breast
tomosynthesis with subsequent percutaneous biopsy were analysed. Four
radiologists (two seniors, R1 and R2, and two juniors, R3 and R4)
independently reviewed exams in 2 steps: mammography alone and
mammography with tomosynthesis. The lesions in the cohort included 39.3%
(61/155) cancers and 60.6% (94/155) benign lesions.
Results
There was almost perfect agreement irrespective of reader
experience for the reading of the combination of mammography and
tomosynthesis, whereas agreement was poor between junior and senior
readers for the reading of mammography alone. Area under the ROC
(AUROC) values for the combination of mammography and tomosynthesis
were significantly better than AUROC values for mammography alone for all
readers except the most experienced, for whom only a tendency was noted.
The proportion of cancers undiagnosed by mammography alone that were well
diagnosed by the addition of breast tomosynthesis was 6.5% (4/61), 13.1%
(8/61), 27.8% (17/61) and 26.2% (16/61) for Readers 1, 2, 3 and 4,
respectively. The proportion of false positi ve cases induced by the addition of
breast tomosynthesis to mammography was 2.1% (2/94), 2.1% (2/94), 9.5%
(9/94) and 12.7% (12/94) for Readers 1, 2, 3 and 4, respectively.
Conclusion
Adding breast tomosynthesis to mammography improved
sensitivity and negative predictive value for all readers except for the most
experienced one.
B-0332 10:57
Digital mammography vs digital breast tomosynthesis in an enriched
sample
P. Martínez Miravete
1, M. Paramo2, R. Salazar2, J. Etxano2, L. Apesteguia2,
L.J. Pina Insausti2; 1Zaragoza/ES, 2Pamplona/ES
(
[email protected])
Purpose: To evaluate the sensitivity and s pecificity of digital mammography
(DM) versus digital breast tomosynthesis (DBT) in an enriched sample.
Methods
and Materials: A sample of 504 patients with both DM and DBT was
retrospectively evaluated by two blinded experts. The mean age was 48.4 y/o
(21-88). Only 32 (6.3%) showed ACR I density pattern and 230 (45.6%) had
dense patterns (III & IV). Clinical and ultrasound studies were not available.
The enriched sample included 61 cancers (12.1%) and 112 biopsy proven
benign lesions (22.2%). The remaining 331 cases were normal or benign (1-
year follow-up). COMBO mode (DM and DBT) was used. The patients were
categorised as negative (BI-RADS cat 1&2) or positive (BI-RADS 3-5).
Multifocal/multicentric were not consid ered. Data were analysed by using the
SPSS (15.0) and PEPI softwares to calculate the concordance between the
readers and to compare the sensitivity and specificity.
Results
The concordance between the readers for the BI-RADS classification
was moderate for DM (kappa= 0.49) as well as for DBT (kappa=0.58). DBT
significantly increased the sensitivity of both readers compared with DM alone
(reader 1: DM 82%, DBT 95.1%; p < 0.05; Reader 2: DM 72.1%, DBT 80.3%;
p 0.05) and for reader 2 (DM 67.6 % vs
DBT 68.3%; p> 0.05).
Conclusion
The concordance between the readers was moderate in this
enriched sample. DBT significantly increas ed the sensitivity of both readers but
there were no significant changes regarding the specificity.
B-0333 11:06
First experience with the new generation low-dose digital breast
tomosynthesis: can 2D synthetic image replace digital mammography in
combination with digital breast tomosynthesis?
M. Locatelli
1, M. Tonutti2, A. Trianni3; 1Gorizia/IT, 2Trieste/IT, 3Udine/IT
(
[email protected])
Purpose: Digital breast tomosynthesis (DBT) is a new promising technique,
expected to improve digital mammography (DM) interpretation by reducing
tissue superimposition. DBT acquisition provides plane images focused at
different depths of the breast. Moreover, synthetic 2D (2Dtomo) images
analogue to DM images can be reconstructed. The aim of this study is to
evaluate 2Dtomo associated with DBT, compared with DM associated with
DBT in terms of added diagnostic value and dose received by the patient.
Methods
and Materials: DBT was performed on 78 patients (symptomatic or
screening-recalled) after DM examination with the new generation GE system
(Senographe Essential). A total of 89 exams underwent double-blinded review
by two experienced breast radiologists. The diagnosis was then confirmed by
ultrasound, biopsy, magnetic resonance or contrast enhanced spectral
mammography. For all exams, dosimetric information was also collected.
Results
Inter-observer accordance was in 90% of DBT images and 87% of
2Dtomo images. DBT findings were concordant with the final diagnosis in 98%
of the cases and 2Dtomo in 73%. 2Dtomo is a synthetic image obtained
processing the information of DBT without additional dose. The combination
2Dtomo/DBT would reduce the patient dose of about 50%. In addition, 2Dtomo
improves the negative predictive factor (NPV). But this is only an apparent
improvement, since 2Dtomo actually demonstrated really low sensitivity.
Moreover, 2Dtomo significantly decreases the conspicuity of details compared
with DM and DBT, independently from the final diagnosis and from breast
density.
Conclusion
The combination of 2Dtomo plus DBT cannot, at present, replace
DM in screening workflow.
B-0334 11:15
Improved detection of architectural distortion in digital mammography
using distortion-weighted image (DiWI): a new mathematical image-
filtering technique by the pinwheel-framelet processing method
T. Ueda, H. Tsunoda, H. Arai, E. Morishita, G. Akaike, S. Arai; Tokyo/JP
(
[email protected])
Purpose: To investigate the usefulness distortion-weighted image (DiWI) that
is processed by the new pinwheel-framelet processing method specific to
enhance architectural distortion in digital mammography.
Methods
and Materials: The institutional review board approved the
retrospective study. A total of 100 pairs of digital mammograms in CC and
MLO views in half with and in half without architectural distortion were selected
for the study. The diagnosis of a board-certified breast radiologist with 20 years
experience was used as the gold standard. Original mammograms were
processed to DiWI, a digitally-filtered image using the pinwheel-framelet
processing method that is newly developed by our group based on the
mathematical modelling of human visual processing. A board-certified breast
radiologist (R1) who has 10 years experience and a radiology-resident (R2)
who has 1 year experience of mammography assessed original digital
mammograms with and without DiWI independently for the presence and the
grades of distortion of mammogram. The result was assessed by area under
curve (AUC) using receiver operating characteristic analysis.
Results
The AUC without DiWI by R1 and R2 were 0.96 and 0.81 and the
AUC with DiWI were improved to 0.98 and 0.89, respectively The AUC by R1
was significantly lower than that by R2 (p < 0.01) but showed no significant
difference with DiWI (p=0.25).
Conclusion
DiWI improved the diagnostic accuracy to assess architectural
distortion of digital mammography, especially in less-experienced reader.
B-0335 11:24
Opportunistic breast cancer screening in the Netherlands
E. Paap1, J.M.H. Timmers1, H.M. Zonderland2, M.J.M. Broeders1,
G.J. den Heeten1; 1Nijmegen/NL, 2Amsterdam/NL (
[email protected])
Purpose: To compare the demand and indications for opportunistic breast
cancer screening of women who are part of the target population of the Dutch
organised programme (50-75) to women who are not invited for screening.
Methods
and Materials: The study was conducted at the radiology
department of the Academic Medical Centre, Amsterdam, The Netherlands. A
total of 1,000 randomly selected women were included: 500 in the age group
40-49, and 500 in the age group 50-59. All included women were referred to
the hospital by their general practitioner and received a mammographic
examination between 1 January 2006 and 22 May 2011. Indications for referral
S208
BA C D E F G
Friday
were retrieved from medical records. Based on these indications,
mammographic examinations were classified into three groups: opportunistic
screening, screening for women with increased familial risk and diagnostic
examinations. The proportion of opportunistic screening was compared
between both age groups using the Chi-squared test.
Results
There was no difference in the proportion of opportunistic screening
in both age groups (28% versus 25% in the age groups 40-49 and 50-59,
respectively; p=0.549). Screening for women with increased familial risk (8%
versus 7%) and diagnostic examinations (65% versus 68%) showed similar
Conclusion
In contrast to our expectations, the proportional opportunistic
screening in the age group not invited for screening was similar to that in the
age group invited for screening. A linkage with the screening register could
improve the assessment of opportunistic screening in the age group above 50.
Author Disclosures:
G.J. den Heeten: Advisory Board; former member of the medical advisory
board of Matakina.
B-0336 11:33
Does a false positive recall for assessment deter women from
subsequent breast screening?
R. Sinnatamby1, A. Herbert2, S. Garnett3, C. Beattie4, J. Lavelle5, I. Lyburn6,
A.J. Maxwell7; 1Cambridge/UK, 2London/UK, 3Preston/UK, 4Liverpool/UK,
5Lancaster/UK, 6Cheltenham/UK, 7Manchester/UK
(
[email protected])
Purpose: Potential harms of breast screening include possible psychological
morbidity of recall and workup for benign or normal outcome. We have
evaluated the subsequent failure to attend screening as a surrogate for this
potential adverse effect.
Methods
and Materials: A cohort of 253,017 women screened in 5
geographically and demographically di fferent centres within a national
programme were studied. Subsequent re-attendance rates in those who
received a normal result were compared with those who were recalled for
assessment with normal or benign outcome. Data was extracted from the
national database to assess effects of age, biopsy at workup and type of
screen, prevalent or incident.
Results
Following a prevalent round screen, women were slightly but
significantly more likely to re-attend after false positive recall than after a
normal examination (87.7% vs. 86.0%; 95% CI: 0.54% to 2.62%). Following
incident round screens overall re-attendance was higher than in prevalent
rounds (92.4% vs. 86.2%), with no signific ant difference after false positive
recall. However, women who underwent needle sampling or open biopsy were
12% and 60% less likely to re-attend than women with a normal screen
(p < 0.001). Odds of re-attendance decreased significantly with increasing age.
Conclusion
This study suggests that any psychological morbidity resulting
from breast screening assessment does not deter most women from
subsequent attendance. Nevertheless invasive workup, particularly open
biopsy but also percutaneous biopsy, does have a deleterious effect on re-
attendance and should be used prudently.
Results
from this study have been published online: J Med Screen, Aug 2013
Author Disclosures:
R. Sinnatamby: Research/Grant Support; National Institute for Health
Research, Cambridge Biomedical Research Centre. A.J. Maxwell:
Research/Grant Support; NHS North West.
B-0337 11:42
Contralateral breast cancer: incidence according to ductal or lobular
primary phenotype: a large dual cancer registry-based study
N. Sharma1, F. Langlands1, J. White1, O. Kearns2, S. Cheung2, R. Burns2,
K. Horgan1, D. Dodwell1; 1Leeds/UK, 2Birmingham/UK
(
[email protected])
Purpose: Historically there has been an association between invasive lobular
carcinoma ILC and an increased risk of developing a contralateral breast
carcinoma. We aimed to identify any differences in the incidence of
contralateral breast cancer between patien ts with primary tumour diagnosis of
invasive ductal carcinoma (IDC) and ILC.
Methods
and Materials: Data from the Northern & Yorkshire Cancer Registry
& Information Service (NYCRIS) and the West Midlands Cancer Intelligence
Unit (WMCIU) from 1998 - 2003 for all registered cases of invasive breast
cancer of either pure ductal or pure lobular reported histology were obtained.
The invasive status of the contralateral tumour diagnosis and tumour
morphology was collected. Chi-Square tests were undertaken to examine the
differences in contralateral rates for both registries and univariate analysis to
ascertain which predictors affected contralateral breast cancer risk in WMCIU.
Results
A total of 38132 patients were studied, 32735 (86%) with IDC and
5397 (14%) with ILC. There was no significant difference between the numbers
of contralateral breast cancers according to original cancer histology, 901
(2·8%) patients with IDC vs 166 (3·1%) patients with ILC, p=0·169. The
analysis of WMCIU cases showed no association between original histology,
age at diagnosis, tumour grade, use of radiotherapy for the primary cancer or
use of systemic therapy and development of a contralateral breast cancer.
Conclusion
There is no apparent increase in risk of developing a
contralateral breast cancer according to the primary cancer histology either
IDC or ILC.
B-0338 11:51
In the context of overdiagnosis, does size matter?
S. Bhuva, I. Haigh, M. McMahon, B. Dall, D. Dodwell, N. Sharma; Leeds/UK
(
[email protected])
Purpose: The Marmot review showed that although breast screening saves
lives, it is harmful through overdiagnosis; treating cancers that would not
otherwise have ever become clinically apparent. Currently, no size threshold
exists for recalling screening patients with calcifications. Our aim was to assess
whether a minimum size threshold would reduce overdiagnosis.
Methods
and Materials: We conducted a retrospective review of 375
screening patients with microcalcifications over 24 months. We assessed all
patients with pure calcifications 10 mm documenting core biopsy, final
histology and treatment.
Results
61 cases of microcalcifications 10 mm: 8 benign, 40 in situ cancers
and 13 invasive cancers. This group was subcatagorised into calcifications:
05 mm (24 patients) and 5 10 mm (37 patients). In the '0 5 mm' group, there
were 16 in situ (low grade 1; intermediate grade 7; high grade 8) and 2
invasive cancers (G2 ductals ER/PR+Her2- node negative). In the '5 10 mm'
group, there were 24 in situ (low grade 3; intermediate grade 12; high grade 9)
and 11 invasive cancers (4 G1ER+Her2- node negative; 6 G2: (5 ER+Her2-, 1
triple negative). 1 of these 6 cases was node positive (micrometastasis) and 1
G3ERPR+Her2- node negative). All underwent wide local excision, and all but
one patient with invasive carcinoma received radiotherapy.
Conclusion
Recalling focal clusters of microcalcifications ( < 10 mm) identified
a high rate of cancers: 66%(40/61) in situ and 21% (13/61) invasive. Regarding
overdiagnosis: 51% (27/53) of cancers were low/intermediate grade DCIS or
G1 invasive and 49% (26/53) were high-grade DCIS or invasive G2/3.
Therefore, size is not a key factor in reducing overdiagnosis.
10:30 - 12:00 Room G/H
Genitourinary
SS 507
Prostate cancer: diagnosis, extension and
recurrence
Moderators:
T. Durmus; Berlin/DE
J. Richenberg; Brighton/UK
B-0339 10:30
MR accuracy for the diagnosis of prostate cancer
A.P. Moffa, R.L. Cazzato, R. Del Vescovo, B.B. Zobel; Rome/IT
(
[email protected])
Purpose: To determine the accuracy of mp-MRI for prediction of extracapsular
extension (ECE) in patients with prostate cancer (PCa) classified as "low risk".
Methods
and Materials: Thirty-one patients with biopsy-proved PCa
underwent endorectal MRI prior to radiation therapy. Histological features
evaluated were Gleason score, affected lobe, greatest percentage of cancer in
all core biopsy specimens, and percentage of cancer-positive core specimens
in all core biopsy specimens. The likelihood of ECE was assessed
retrospectively on the basis of MR five- points scale, where patients are divided
into two groups, A and B (Group A MR score < 3; Group B MR score 3).
Group B scores were considered suggestive for ECE. Pearson's chi-squared
test and t Student were used to correlate histological and clinical data with MR
parameters for ECE. All the statistics were developed in the environment of
MATLAB® (Math Works, Inc). A difference with P
<.05 was considered
significant.
Results
In Group B serum PSA levels, percentage of cancer-positive core
specimens in all core biopsy specimens, and ADC values were predictors of
ECE ( P <.05). There is a trend of correlation between ADC values and PSA
levels (p=0.55); percentage of cancer-positive core specimens in all core
biopsy specimens and greatest percentage of cancer in all core biopsy
specimens (p=0.48); and ADC values and greatest percentage of cancer in all
core biopsy specimens (p= 0.11).
Conclusion
Detection of locally advanced disease improved substantially
when MRI was added to routine clinical staging; mp-MRI is able to assess ECE
in 39% of cases in ''low risk'' PCa patients.
S209
BA C D E F G
Friday
B-0340 10:39
The role of learning curves as a function of the expertise in the prostate
MRI
F. Barchetti, V. Panebianco, C. Zini, V. Forte, I. Elena, C. Catalano; Rome/IT
Purpose: To evaluate the changing of sensitivity in detecting prostate cancer
(PC) assessing the learning curves with the advance of experience.
Methods
and Materials: 900 patients who underwent a Mp-MRI examination
of the prostate were independently retrospectively evaluated by 2 readers:
reader A (R.A) and reader B (R.B).
Results
170 patients out of 900 were originally assessed negative for the
presence of PC. R.A in 69 out of 170 patients detected subsequently an
altered focus and 2 further suspecious areas in 30 men, while R.B detected a
suspecious lesion in 63 patients. 330 patients out of 900 in the first reading
were considered positive for an alte red focus: in the second reading R.A
discovered a further area of suspiciuos malignancy in 157 patients, while R.B
in 104 patients detected a further lesion. In 350 patients out of 900 initially
were estimated two suspicious zones: in the second reading, R.A discovered a
further zone of suspected malignancy in 180 patients, while R.B in 121 patients
detected a further lesion. 50 patients ori ginally were considered positive for 3
suspected areas: in the second reading session R.A discovered a further zone
of suspected malignancy in 11 patients, while R.B in 5 patients. All in the
sensitivity of R.A in detecting foci of mo rpho-functional changings increased
from 61% to 97% and for R.B from 49% to 89%.
Conclusion
The sensitivity in detecting suspicious areas of PC increases
substantially with the advance of the expertise reaching a detecting rate
statistically significant (P < 0.05).
B-0341 10:48
Utility of exponential apparent diffusion coefficient for evaluating
peripheral zone prostate cancer at 3 T: preliminary experience
S. Park, C. Kim, B. Park, M. Cha; Seoul/KR (
[email protected])
Purpose: To investigate the utility of exponential apparent diffusion coefficient
(eADC) derived from diffusion-weighted imaging (DWI) in evaluating peripheral
zone (PZ) prostate cancer at 3 T.
Methods
and Materials: 74 patients who had PZ cancers of 0.5 cm 3 or greater
on surgical specimens and performed DWI at 3 T were enrolled in this
retrospective study. The eADC and ADC maps were obtained from DWI data,
respectively. Based on radiologic-patho logic correlation, both eADC and ADC
values (×10
-3 mm2/s) for cancers and benign PZ tissues were measured by two
independent radiologists, and the results were compared. Contrast-to-noise
ratio (CNR) and signal-to-noise ratio (SNR) were measured on eADC and ADC
maps. The correlation between eADC or ADC values of cancers and Gleason
score was also assessed. Statistical analyses were performed using Wilcoxon
signed rank test, intraclass coefficient (ICC), Bland-Altman test, and Spearman
correlation analysis.
Results
The median eADC (0.48) and ADC (0.73) values of cancers were
significantly different as compared with those of benign PZ (0.19 and 1.64,
respectively) (P < 0.001). For cancers, eADC showed good interreader
agreement (ICC= 0.758) and interreader variability of 1.1%. The SNR was
significantly greater in eADC than ADC (P < 0.001), while the CNR was similar
between eADC and ADC (P= 0.241). A moderate correlation between eADC
(rho= 0.690) and ADC (rho= -0.694) of cancers and Gleason score was seen,
respectively.
Conclusion
Our preliminary results suggest that eADC may be a useful
imaging tool in evaluating PZ prostate cancers, with improved SNR compared
with ADC.
B-0342 10:57
Preoperative MRI improves the surgical outcome in patients with non-
palpable prostate cancer in a randomised study
E. Rud, D. Klotz, K. Rennesund, A. Svindland, E. Baco, L. Eri, H.B. Eggesbø;
Oslo/NO (
[email protected])
Purpose: The aim of this study was to evaluate whether MRI prior to
prostatectomy improved the surgical outcome.
Methods
and Materials: Prospective study including 411 patients randomised
to MRI or not prior to prostatectomy (age: 63 ±8 years and PSA: 8.0±5.6 ng/ml).
Gleason score in biopsy were 6: 34%, 7a: 38%), 7b: 11%, 8: 15%, and 9: 2%.
Clinical T classification were: cT1: 54%, cT2: 43% and cT3: 3%. The MRI
included high-resolution axial T2w images a nd DWI. Surgical excision was uni-
or bilateral nerve sparing (UNS or BNS) or non- nerve sparing (NNS). Positive
surgical margins (sm+) was defined as extension of tumor into the cut surface.
Results
The overall rate of sm+ (no MRI vs. MRI) was 23% vs. 20% (p=0.39).
In cT1, the rate of sm+ was 27% vs. 16% (p=0.05). No difference was found in
patients with cT2 and cT3. The sm+ rate according to the surgical procedure
(no MRI vs. MRI); BNS: 19% vs. 12% (p=0.33), UNS: 21% vs. 19% (p= 0.74),
NNS: 30% vs. 25% (p=0.57). In pT2 and pT3, the rate of sm+ (no MRI vs. MRI)
was 8% vs. 5% (p=0.40) and 39% vs. 32% (p=0.36). In low, intermediate and
high risk d'Amico groups, the rate of sm+ was 13% vs. 6% (p=0.32), 24% vs.
23% (p=0.90) and 32% vs. 30% (p=0.77).
Conclusion
Preoperative MRI reduces the risk of positive surgical margins
after RALP in patients with non-palpable prostate cancer.
B-0343 11:06
Is there a role for functional MR techniques for the assessment of
extracapsular extension in prostate cancer? A preliminary analysis with
histopathologic correlation
U.I. Attenberger
1, S.O. Schönberg1, D. Hausmann1, A. Weidner1,
J.N. Morellini2, D.J. Dinter1, A. Haecker1, M. Sertdemir1; 1Mannheim/DE,
2Texas, TX/US (
[email protected])
Purpose: The presence of extracapsular extension (ECE) has significant
impact for treatment options in prostate cancer (PC). T2-w MRI-sequences are
most commonly used for preoperative assessment of ECE, with variable
accuracy. The aim is to evaluate the diagnostic accuracy of T2w-imaging vs.
quantitative DWI-MRI (ADC) and DCE-MRI parameters (plasma flow (PF),
mean transit time (MTT)) for detection of capsular invasion (CI) and ECE.
Methods
and Materials: Triplanar T2w-sequences of 34 patients with PC
were analysed prior prostatectomy by two blinded/experienced readers. DCE-
and DWI-MRI were analysed by a third radiologist, in concordance to the
histopathological analysis. Sensitivity (SS) and specificity (SP) of T2w, ADC,
PF and MTT for prediction of CI/ECE were determined by area-under-the-
receiver-operating characteristics analysis. ADC-, PF- and MTT-values were
normalised by the PC/normal tissue ratio.
Results
By histopathologic analysis, 14/34 pa tients had ECE, 11/34 patients
had only CI and 9/34 patients had no ECE/CI. The interobserver agreement for
detection of ECE/CI of T2w-sequences was poor ( 5=0.1), SS/SP for detecting
ECE was 28/50%. PF-, MTT- and ADC-ratios in ECE differed significantly
(p < 0.001) from cases without ECE. The AUC and SS/SP of ECE for PF-/MTT-
/ADC-ratios was 0.98/92%/95%, 0.92/100%/80 and 0.69/86%/50%,
respectively. PF- and MTT-ratios between CI and without CI/ECE differed
significantly (PF, p < 0.0001; MTT, p=0.0134), SS/SP, 84%/89% for PF and
SS/SP, 52%/100% for MTT-ratios, no significant differences regarding ADC-
ratios could be identified.
Conclusion
ECE and CI can be assessed by quantitative DCE-MRI analysis
with great diagnostic confidence. Moreover, quantitative PF- and MTT-values
detect ECE/CI with greater specificity than ADC-value analysis.
B-0344 11:15
Usefulness of additional apparent diffusion coefficient (ADC) values to
morphologic MR imaging in predicts extracapusular extension (ECE) of
prostate cancer
T. Manabe, M. Oda, E. Arai, Y. Kanai, M. Miyake, M. Komiyama, H. Nakanishi,
M. Kusumoto, Y. Arai; Tokyo/JP (
[email protected])
Purpose: In our previous study, we found that ADC values of prostate cancer
with ECE are significantly lower than those of without ECE. The purpose of this
study was to assess the predictive value for ECE of prostate cancer of MRI
using morphologic (T2-weighted imaging [T2WI] and diffusion-weighted image
[DWI]) alone and combined with ADC values.
Methods
and Materials: This retrospective study included 230 patients who
underwent 3.0-T MRI before total prostatectomy. We reviewed morphologic
MRI and graded the likelihood of ECE on a five-point scale. ROIs were placed
in the dominant cancerous area.ADC values were calculated by at least square
(b=0, 800, 1500).We consider the possibility of ECE is higher when the ADC
values were lower, but it limited to the auxiliary role of the morphologic MRI.
We graded the likelihood of ECE on a five-point scale using additional ADC
values to morphologic MRI. Diagnostic performance (area under receiver
operating characteristic [ROC] curve: AUC), accuracy, sensitivity, specificity,
positive predictive value (PPV), and negative predictive value (NPV) were
evaluated.
Results
AUC improved significantly after additional ADC values; AUC=0.8044
(MRI alone), AUC=0.8494 (MRI+ADC value), (p=0.0003). Morphologic MRI
alone showed accuracy, sensitivity , specificity, PPV, and NPV of 73.5%,
68.0%, 77.4%, 68.6% and 76.9%, respectively. Additional ADC values showed
accuracy, sensitivity, specificity, PPV, and NPV of 79.1, 73.2%, 83.5%, 76.3%
and 81.0%, respectively.
Conclusion
Additional ADC values to morphologic MR imaging improve the
predictive value of ECE of prostate cancer.
S210
BA C D E F G
Friday
B-0345 11:24
3 T diffusion tensor imaging (DTI) in the evaluation of periprostatic nerve
bundle before and after radiation therapy
C. Zini, F. Barchetti, V. Forte, D. Musio, C. Catalano, V. Panebianco; Rome/IT
(
[email protected])
Purpose: To assess diffusion tensor imaging (DTI) at 3 T for evaluating the
periprostatic nerve bundle in terms of neuranatomical distribution, density and
relationship with the capsule before and after radiation therapy (RT).
Methods
and Materials: 63 patients were enrolled. All underwent a
multiparametric-MRI examination of the prostate at 3 T magnet (Discovery
M750, GE) equipped with an endorectal and a surface coil, before and after 2
months of radiation treatment (35 cycles). Scan protocol included: a
morphological study obtained with TSE high-resolution T2-weighted sequences
on multiple plans, a dynamic study with contrast medium for localisation of the
lesion, a diffusion study (DWI) with different b values (500.1000,3000) and DTI
technique (fiber tracking) using a b value of 1000 with 16 directions.
Results
In all cases, before RT it has been possible to display the
periprostatic nerve bundle in terms of anatomical distribution, density and
distance of the nerve fibers from the capsule; after RT we observed,
respectively, superposition of the findings in 27 patients, partial integrity of the
fibers in 31 patients (loss of nerve fibers ranging from 19% to 35%, mean
26.3%) and massive rarefaction of the nerve fibers in 5 patients (loss of nerve
fibers ranging from 42% to 59%, mean 47.8%). These results compared with
the IIEF-5 test showed a statistically significative correlation (p < 0.05).
Conclusion
DTI technique allows a complete visualisation of the periprostatic
nerve bundle and plays an important role in the evaluation of nerve fibers
damage in patients who underwent RT.
B-0346 11:33
Preoperative lymph node staging in patients with primary prostate cancer
using diffusion-weighted magnetic resonance imaging and [11C] choline
PET/CT: which method is better?
T. Vag, M. Heck, A. Beer, M. Schwaiger, M. Souvatzoglou, M. Eiber;
Munich/DE (
[email protected])
Purpose: Lymph node staging in primary prostate carcinoma using
conventional Magnetic Resonance Imaging (MRI) and Computer Tomography
(CT) relies on size measurements, in ove rall exhibiting low sensitivity and
specificity. New promising techniques including diffusion weighted imaging
(DWI) and [11C]choline PET/CT can give additional functional information. The
aim of this study was to compare diagnostic performance of DWI and
[11C]choline PET/CT in the assessment of preoperative lymph node status in
patients with primary prostate cancer.
Methods
and Materials: 33 patients with primary prostate carcinoma
underwent DWI and [11C]choline PET/CT prior to radical prostatectomy and
extended pelvic lymph node dissec tion. Functional parameters including
maximum standardised uptake value (SUVmax) and apparent diffusion
coefficient (ADC) of identified lymph nodes were measured and correlated with
histopathology. Performance of both modalities was compared by calculation
of receiver operator characteristic (ROC) curve using histopathology as
standard of reference.
Results
A significant difference between malignant and benign lymph nodes
was observed for mean ADC (1.16 vs. 0.93 mm2/s) and SUVmax (1.95 vs.
4.31). ROC curve analysis revealed optimal ADC threshold of 1.01 mm2/s for
differentiating benign form malignant lymph nodes with a corresponding
sensitivity/ specificity of 77.41%/ 77.05% and an Area under the Curve (AUC)
of 0.810. The optimal threshold for SUVmax was 2.66 with corresponding
sensitivity/ specificity of 74.19%/ 80.49% and an AUC of 0.819.
Conclusion
DWI and [11C]choline PET/CT reveal a similar diagnostic
performance for pre-operative lymph-node staging of prostate cancer.
B-0347 11:42
Discrimination of benign and malignant lymph nodes in prostate cancer:
diameter measurement vs DWI, ADC mapping or signal intensity at T2w-
STIR?
M. Regier, C. Seiwerts, F.O. Henes, H. Kooijman, G. Sauter, G. Adam,
L. Budaeus; Hamburg/DE (
[email protected])
Purpose: To determine the accuracy of quantitative MRI using diffusion-
weighted MRI (DWI) and signal intensity measurement at T2w STIR in prostate
cancer to compare these to histopathology.
Methods
and Materials: 59 consecutive patients at high-risk following
D´Amico criteria underwent pelvic MRI one day before prostatectomy. A
standardised T2w STIR and DWI sequence were applied (b-values:
0.25.75,100,200,500 and 900). Short (SAD) and long axis diameters (LAD) and
mean and maximum signal intensity of pelvic nodes were recorded at T2w
STIR. ADC calculation was performed and mean (ADCmean) and minimum
ADCs (ADCmin) were determined. 1393 lymph nodes were removed and
histopathologic workup was performed. Sensi tivity, specificity, positive- and
negative-predicitve-values for the discrimination of benign and malignant
nodes were calculated using Wilcoxon and chi-square test.
Results
Histopathology revealed malignant nodes in 21 patients. In these
nodes, the mean SAD and LAD were 8.3 mm (range, 3-14.2 mm) and 12.3 mm
(range 4-27 mm). Applying a threshold of 0.98x10-3 mm2/s for the ADCmean
only 2 false positive findings were noted. The ADCmin was the most accurate
discriminator allowing for correct identification of malignant nodes in all patients
with 100% specificty if a threshold of 0.74x10-3 mm2/s was applied.
Determination of mean (p=0.62) and maximum (p=0.07) signal intensities at
T2w STIR did not proof any statistical significance for the discrimination of
nodes.
Conclusion
Although the sensitivity rates of diameter measurement and DWI
were equivalent, assessment of the ADCmin proofed to be the superior
discriminator with an accuracy of 100%. Signal intensity measurements at T2w
STIR have limited capability of detecting malignancy.
B-0348 11:51
The role of combined 3 T DWI with MRS in the differentiation of loco-
regional recurrence from residual glandular tissue after radical
prostatectomy
C. Zini, F. Barchetti, V. Forte, M. Bernieri, V. Panebianco, C. Catalano;
Rome/IT (
[email protected])
Purpose: To distinguish between loco-regional recurrence and residual
glandular healthy tissue using 3 T DW I and MRS after radical prostatectomy
(PR).
Methods
and Materials: 60 patients who underwent RP with persistence of
minimum PSA values or modest rise of PSA values within 6 months (range
between 0.2 ng/ml and 1.5 ng/ml) were enrolled for 3 T multiparametric-MRI
examination. The protocol included: a morphological study with high-resolution
T2-weighted sequences, a dynamic study with T1-weighted GRE sequences
acquired after intravenous administration of contrast medium, a diffusion-
weighted (DWI) study with exponential b-values (0, 500, 1000, 3000) and
three-dimensional multivoxel spectroscopic sequence (MRS). Each patient was
evaluated independently by two radiologists. MRI results were validated by
transrectal ultrasound biopsy.
Results
In all cases, a solid tissue (size between 8 mm and 23 mm) was
identified in T2 morphological images. In 49 patients (81%) DWI and MRSI
demonstrated features of malignancy (ADC values ranging from 0.3 to
1.1 mm2/s and a choline-plus-creatine-to-citrate ratio CC/C in at least 3
adjacent voxels > 0.8. In the remaining 11 patients (19%) DWI and MRS
showed benign features (ADC values > 1.2 mm2/s and a CC/C in at least 3
adjacent voxels < 0.5. All MRI findings were confirmed by histological Results:
39 patients had loco-regional recurrence and 11 patients had residual
glandular tissue.
Conclusion
The combination of DWI and MRS is proved to be a very reliable
tool for distinguish beetween loco-regional recurrence and residual glandular
tissue after RP.
10:30 - 12:00 Room I/K
Neuro
SS 511
Paediatric neuroimaging and
developmental anomalies
Moderators:
V. Mendes Pereira; Geneva/CH
A. Rovira-Cañellas; Barcelona/ES
B-0349 10:30
High-resolution MRI using orbit surface coils vs conventional MRI in the
evaluation of metastatic risk factors in children with retinoblastoma
S. Sirin, M. Schlamann, K.A. Metz, N. Bornfeld, M. Holdt, B. Schweiger,
F. Nensa, P. Temming, S.L. Goericke; Essen/DE (
[email protected])
Purpose: Conventional MRI is a well-accepted, non-invasive imaging modality
for the evaluation of tumor extension in children with retinoblastoma. First
studies using high-resolution MRI with orbit surface coils were promising. The
aim of this study therefore was to assess if high-resolution MRI using orbit
surface coils is superior to conventional MRI regarding the depiction of
metastatic risk factors in children with retinoblastoma.
Methods
and Materials: 66 children (25 female, 41 male, mean age 18.9
months, 67 enrolled eyes) underwent conventional MRI using a standard head
coil on 1.5 T. After the administration of Gadolinium additional high-resolution
T1-weighted sequences were acquired with orbit surface coils. Two reviewers
evaluated both Gadolinium-enhanced T1-weighted sequences regarding the
presence of metastatic risk factors (postlaminar optic nerve infiltration,
S211
BA C D E F G
Friday
choroidal invasion, orbital fat invasion). Histopathologic evaluation after
enucleation served as reference standard.
Results
Depiction of metastatic risk factors increased with high-resolution MRI
using orbit surface coils: Sensitivity and specificity for the detection of
postlaminar optic nerve infiltration were 70.0%/87.7% with high-resolution MRI
using orbit surface coils and 40.0%/86.0% using conventional MRI. High-
resolution MRI using orbit surface coils additionally increased the detection
rate of choroidal invasion (sensitivity/specificity 73.7%/93.8% vs.
31.6%/93.8%). There was one patient with orbital fat invasion in the patient
group, which was only detected in the images acquired with the orbit surface
coil.
Conclusion
High-resolution MRI using orbit surface coils is superior to
conventional MRI using a standard head coil for the evaluation of metastatic
risk factors in children with retinoblastoma.
B-0350 10:39
"White matter choking signs" for diagnosis of focal cortical dysplasia on
3 T MR imaging: retrospective analysis of 165 cases with multi-modality
metabolic imaging and radio pathological correlation
R. Vadapalli, S. JS, M. Panigrahi; Hyderabad/IN (
[email protected])
Purpose: To describe two new signs called "White Matter Choking Sign" and
"WM Choking extended" useful for diagnosis of FCD.
Methods
and Materials: 165 patients in age group of 6-44 years with
refractory epilepsy were included in the retrospective study imaged using Both
TLE and ETLE (extra temporal lobe epilepsy) protocols on a 3 T MRI system
(Achieva ,Philips Health care, Netherlands) with a 3D T1, 3D T2, 3D T2 FLAIR
for detection of occult dysplasia. The data was viewed and post-processed
using a Philips Portal Work station and Advantage Windows (GE health care
system) to generate 3D corticographs of normal, abnormal areas and
correlated with multimodal imaging and pathology.
Results
Three patterns emerged in our series of histopathologically proved
FCD. The FCDS analysed were as follows: 1B (56), IIA (33), IIB (27), III (39).
Sudden truncation or choking of sub-cortical white matter with blurring of
interface (White Matter Choking sign) has positively correlated with Focal
cortical dysplasia in 82%, WM choking sign underlying a cortical laminar
architectural abnormality (White Matter choking Extended sign) has positively
correlated with type IB and Type IIA- 92%, abnormal Medullary Spike Pattern
was seen in Cingulate gyral FCD (n=4), Para sagittal Cortical Ribbon dysplasia
of type IB (n=7). Type 1B and IIA: sensiti vity 92%, specificity 81%, Type IIB
sensitivity 92%, specificity 70%; specificity of type IIB improved with presence
of trans mantel sign (n=27) to 95%.
Conclusion
White Matter Choking Sign and White Matter choking Extended
sign offer optimal sensitivity and specificity for MRI detection of FCD.
B-0351 10:48
Isolated craniosynostoses: is cranial sutures ultrasonography helpful?
S. Bernardo, P. Sollazzo, V. Vinci, M. Saldari, P. Cascone, G. Saponaro,
L. Manganaro; Rome/IT (
[email protected])
Purpose: The aim of this study is to demonstrate the effectiveness of the use
of ultrasound as a diagnostic and follow-up tool in newborn children affected by
craniostenoses.
Methods
and Materials: Between May 2011 and July 2012, 23 children aged
between 1 month and 8 months were referred to our operative unit for
abnormal head shape or small head diameter. We selected 17 children, whose
clinical findings were clinically suggestive for craniostenosis or head molding.
All patients underwent an ultrasound examination and, those positive for
craniostenosis or with an uncertain diagnosis also underwent CT scan
examination; US scan and CT scan were performed within one week from
clinical examination.
Results
Five infants had normal appearance of the cranial sutures on US. In
12/17 infants, US identified premature closure of one or more cranial sutures.
In one case, US was not able to determine the real closure of right coronal
suture and a six months follow-up was needed.
Conclusion
In our experience ultrasound examination has shown to be an
effective, fast, inexpensive and nonrisky method for diagnosis and
assessments in children with craniostenoses, and was able to detect the
presence of synostosis in all patients affected with a 100% match with CT scan
examination.
B-0352 10:57
Prenatal detection of abnormal hippocampal development in
lissencephaly
B. Kunzendorf, E. Schwartz, G. Langs, D. Prayer, G. Kasprian; Vienna/AT
(
[email protected])
Purpose: To detect and quantify differences in the hippocampal morphology
between normal foetuses and cases with lissencephaly.
Methods
and Materials: Standardised coronal T2-weighted foetal MR (1.5
Tesla) sequences of 19 cases with the neuropathological/follow-up imaging
diagnosis of lissencephaly were compared to 36 normal foetuses (age range
20-39 gestational weeks - GW). The boundaries of the hippocampi were
segmented using ITK Snap in order to define 4 lines, using 4 characteristic
hippocampal landmarks and 3D Slicer. 4 angles between these lines were
measured. A midline served as a reference to assess the positioning of the
hippocampus as a whole.
Results
Normal age-related reduction of hippocampal angles (r²=0.387;.000)
could not be observed in lissencephaly cases (r²=.010;.674). In lissencephaly,
the angles were significantly wider than in normal age matched controls
(p=.000; Welch's Test). Only two angles were sufficient to discriminate healthy
from lissencephaly fetuses with a sensitivity of 80% and a specificity of 94.4%.
Normals showed left/right differences in one angle (p=0.009; paired t-test),
whereas in lissencephaly cases, 3 angles were asymmetric (p=.031;.021;.045;
paired t-test). The rotation of the main axis from vertical to horizontal was less
pronounced in lissencephaly on the right side (p=.005; Welch's Test).
Conclusion
Geometrical 2D analysis provides insights into normal and
abnormal patterns of prenatal hippocampal morphology and adds valuable
quantitative data to detect and characterise fetal brain pathologies.
Interhemispheric differences have to be taken into account.
B-0353 11:06
Foetal cortical pattern analysis in commissural dysgenesis
G. Kasprian, E. Schwartz, G. Langs, P. Brugger, D. Prayer; Vienna/AT
(
[email protected])
Purpose: To detect and describe abnormalities and differences in cortical
folding patterns of foetuses with commissural dysgenesis (CD).
Methods
and Materials: Three orthogonal T2-w sequences (1.5 Tesla, slice
thickness 4.4 mm, FOV 230 mm, TE=140 ms) of 12 foetuses with isolated,
partial and associated forms of CD were retrospectively analysed. 2D pattern
analysis consisted of cortical contour delineation (coronal plane) and 2D shape
modelling using a multivariate Gaussian model. For 3D modelling axial, coronal
and sagittal sequences were combined in to isotropic volumes (resolution 0.78-
1.02 mm) using intra-slice motion correction and super-resolution
reconstruction. In these, the shape of the manually delineated cortical contour
was described using a 3D Gaussian model. Results were compared to 12 age-
matched foetuses with normal cerebral development.
Results
Hemispheric asymmetry patterns are less pronounced in the acallosal
group of foetuses as demonstrated by 2D pattern analysis. Hemispheric
asymmetries were less pronounced in the perisylvian brain regions in CD
cases. 3D modelling could readily visualise the dynamic cortical folding
patterns in CD foetuses and could detect sublte differences to normal controls.
Conclusion
2D and 3D modelling and pattern analysis are computerised,
quantitative methods to detect even sub tle differences of atypical cortical
folding patterns of foetuses with CD. In future, these tools may be further
suitable to differentiate cases of isolat ed CD with adverse neurodevelopmental
outcome from those with close to normal development.
B-0354 11:15
Unexpected brain MRI findings in research volunteers
P.A. Rowley, A. Field, E. Simcock, A. Munoz Del Rio, H.A. Rowley; Madison,
WI/US (
[email protected])
Purpose: Brain MRI scans performed in neuroscience studies have revealed a
range of unexpected findings in normal volunteers. The incidence and types of
abnormalities have not been well established in a large population, and best
practice for dealing with such findings is controversial. We undertook this study
to analyse abnormalities discovered by expert MRI readers in a large group of
children and adult research volunteers.
Methods
and Materials: 6441 consecutive subjects ( < 1 to 94 years) were
recruited from a single institution, referred from over 100 IRB-approved brain
research studies. All scans were uploaded to PACS and interpreted by
Neuroradiologists using an on-line structured report. Research technologists
and staff were also prospectively asked to document concerns discovered
while scanning or processing.
Results
On formal neuroradiologic review, normal results were found in
5205/6441 (80.8%). Among 1236 abnormals, 982/6441 (15.2%) were
categorised as follow-up not mandatory; and in 254/6441 (3.9%) follow-up was
recommended. Less than 1% of the abnormalities were prospectively correctly
flagged by research staff. No correlations were established between abnormal
Results
and either gender or age. When volunteers were contacted regarding
abnormal findings, they were almost universally grateful for the information,
and opted for additional clinical evaluation.
Conclusion
Potentially clinically significant abnormalities are seen in nearly
4% of children and adults who volunteer for research brain MRI scans, and
these are only rarely accurately identified by research staff. Routine expert
Radiologic review of all such scans can help facilitate clinical referral when
indicated.
Author Disclosures:
H. Rowley: Consultant; GE, Bracco, Guerbet, Gore, Genentech, and
Lundbeck.
S212
BA C D E F G
Friday
B-0355 11:24
Normal variations of the falx cerebri shape based on MR data
A.-A. Al-Jebaly, M.A. Alkubayyer, I. Alorainy; Riyadh/SA
Purpose: Evaluation of the normal variations of falx cerebri shape based on
MR data.
Methods
and Materials: We retrospectively reviewed 2313 consecutive brain
MR exams done in 2012. Falx cerbri and supratentorial compartment were
manually traced on the mid-sagittal contrast-enhanced T1WI. The falx shape
was assessed by evaluation of falx height and area. Falx height was measured
from the highest point at its inferior edge to a reference line (RL) drawn from
junction of the inferior sagittal and straight sinuses to crista galli. Falx area was
measured in reference to the entire supratentorial compartment area.
Statistical analysis was performed using ANOVA and Chi-square test.
Results
170 exams satisfied our inclusion crit eria (adults with exams including
contrast-enhanced sagittal T1WIs of slice thickness 1.5 mm or less). We
identified three falx shapes. Type-I with D/RL ratio less than 0.33, type-II with
ratio (0.33 - 0.67), and type-III with ratio more than 0.67. These types were
seen in 3%, 68%, and 29% of the cases, respectively. There was significant
difference in the height between the three types (p=0.025). No significant
difference was observed in the absolute falx area (p=0.592), however, a
significant difference in the percentage of falx area to the entire supratentorial
compartment area (p=0.019) was noted.
Conclusion
Falx cerbri shape can be clustered into 3 types. The percentage
of falx area to the entire supratentorial compartment area is different in these
types. This finding may guide future studies to develop a biomarker of
subfalcine herniation risk depending on the falx shape type.
B-0356 11:33
Modality specific activations in working memory in children treated for
cerebellar medullobastoma: an fMRI study
D. Hoang, A. Pagnier, E. Cousin, K. Guichardet, I. Schiff, F. Dubois-Teklali,
A. Krainik; Grenoble/FR (
[email protected])
Purpose: Children treated for a cerebellar medulloblastoma demonstrated
cognitive disorders in working memory (WM), especially visuospatial WM,
leading to an impairment of school performance. The purpose of recent study
is to describe the cerebellar involvement in specific cognitive deficits observed
in these children.
Methods
and Materials: Nine healthy volunteers children (11.1 ± 2.2 yo), were
compared to 5 patients treated for cerebellar medulloblastoma (12.1 ±0.6 yo).
All subjects were native French speakers, right-handed, with a global IQ of 70-
130. The participants were examined through 4 block-design 1-back tasks in
the sensorial modality (visual/auditory) and the nature of the cues
(verbal/nonverbal), using BOLD fMRI. Data was analysed by ANOVA with 2x2
factorial design, using SPM8 and SUIT (spatially unbiased infra-tentorial and
cerebellar template).
Results
4/5 patients had a WM deficit following a resection of the left posterior
cerebellar lobe (CrusI/II, lobule VIIb/VIII/IX) and inferior part of vermis; the only
patient without WM deficit was the only one without this region resection.
BOLD activations for visual vs. auditory and nonverbal vs. verbal contrast were
found in the left posterior cerebellar lobe of healthy subject group.
Conclusion
The cerebellum plays the same role in WM in children as that has
been previously described in adults. The left posterior cerebellar lobe may
involve the visuospatial WM.
B-0357 11:42
Value of DSA in the diagnostic workup of pulsatile tinnitus
C. Deuschl, S. Göricke, G. Lehnerdt, O. Kastrup, O. Müller, M. Forsting,
M. Schlamann; Essen/DE (
[email protected])
Purpose: Pulsatile tinnitus is a rare complaint, which can be a symptom of
several pathologies, e.g. dural arteriovenous fistula (DAVF), arteriovenous
malformation (AVM), intracranial stenosis or glomus tympanicum
paraganglioma. The current diagnostic pathway includes an extensive
neurological examination, cranial MRI and diagnostic digital subtraction
angiography (DSA) as gold standard in imaging. This retrospective study
evaluates the additional diagnostic impact of DSA for diagnostic workup in
comparison to MRI.
Methods
and Materials: Fifty-four consecutive patients with pulsatile tinnitus
treated in our institution between 2002 and 2013 were included in this
retrospective study. All patients had a diagnostic workup including DSA and
cerebral MRI. MRI examinations were blinded for DSA results and
retrospective analysed by two experienced neuroradiologists ( > 10y) in
consensus. All MRI sequences were analysed separately.
Results
DSA revealed pathologic findings in 37 of the 54 patients. 26 patients
had DAVF, two patients had AVM, two patients a galeal AV fistula, four
patients glomus tympanicum paraganglioma, two patients carotid-sinus-
cavernosus-fistula and three patients had other pathologies. All pathologies,
which caused the pulsatile tinnitus were detected by MR imaging.
Conclusion
In our study DSA revealed no further information in patients
without any detectable MRI pathology. We suggest that cranial MRI-protocol
should contain a time-of-flight-angio graphy (fistula, stenosis), a contrast-
enhanced-angiography of the supraaortal vessels (fistula, stenosis), a fat-
saturated, contrast-enhanced T1-weighted sequence of the skull base
(paraganglioma) and a T2-weighted sequence (fistula, paraganglioma). DSA is
only recommended when MRI is suspicious for pathology. For the grading of
fistula DSA is still mandatory.͒͒
B-0358 11:51
Postmortal developing of ADC measured with ex vivo DWI of the brain: a
comparison study of in vivo and ex vivo
J. Yamamura1, S. Keller1, B. Schönnagel1, T.M. Schmidt1, R. Fischer2;
1Hamburg/DE, 2Oakland, CA/US (
[email protected])
Purpose: Changes in water diffusion can be quantified by diffusion-weighted
MR imaging; for example, to diagnose ischemic stroke. However, there are
only few works about changes in post-mortem brain. The aim of this study was
to examine for a typical developing of ADC after death and to compare the
values to in vivo brain.
Methods
and Materials: 21 corpses were scanned (13 male, 8 female). Mean
age was 75.5 ± 0.7 years and mean weight 74.2 ± 18.3 kg. All died a natural
cause of death. They were scanned with a 1.5 T MRT (Siemens Magnetom
Symphony; Erlangen, Germany). Scans were repeated in time lags of 1 h.
Diffusion-weighted imaging (DWI) was performed with b values of 0 and 100.
An ADC-mapping was calculated in thalamus, cerebrum and cerebellum. The
so-obtained values were then statistically compared to healthy volunteer ( n=5)
and to the literature. Student t test was performed for statistical analyses.
Results
The ADC in the three examined regions (cerebrum, cerebellum,
thalamus) decreased during the examination in a characteristical way. The
allocation of ADC values between ex vivo and in vivo is significantly different
and can be described by a Gaussian distribution ( p
< 0.005).
Conclusion
Ex vivo ADC values are signific antly different to the in vivo
literature values. Post-mortem DWI of the brain may be able to help to assess
the time of death.
10:30 - 12:00 Room L/M
Abdominal Viscera
SS 501
MRI of diffuse liver disease
Moderators:
T. Denecke; Berlin/DE
N. Papanikolaou; Iraklion/GR
B-0359 10:30
Intravoxel incoherent motion diffusion-weighted imaging for staging
hepatic fibrosis
S. Ichikawa, U. Motosugi, H. Morisaka, K. Sano, T. Ichikawa; Chuo-shi,
Yamanashi/JP
Purpose: To investigate the relationships between the degree of hepatic
fibrosis and parameters calculated using intravoxel incoherent motion (IVIM)
imaging of the liver.
Methods
and Materials: We included 100 patients, divided into 3 groups:
group A, without hepatic fibrosis (n=41); group B, with chronic liver disease (F1-
F3) (n=20); group C, with cirrhosis (n=39). IVIM imaging was used to acquire
diffusion-weighted images at 11 b values (0, 10, 20, 30, 40, 50, 80, 100, 200,
500, and 1000 s/mm 2). The diffusion coefficient of pure molecular diffusion (D),
diffusion coefficient of micro circulation or perfusion-related diffusion (D*),
perfusion-related diffusion fraction (f), and apparent diffusion coefficient (ADC)
were compared among the 3 groups. Receiver operating characteristic curve
analysis was also performed to determine the optimal cut-off value and
accuracy of IVIM and MR elastography (MRE) for staging hepatic fibrosis.
Results
Only mean D* value was significantly different amongst the 3 groups
(group A, 76.0 × 10 -3 mm2/s; group B, 64.2 × 10 -3 mm2/s; group C, 57.9 × 10 -
3 mm2/s; P < 0.0001). There were no significant differences in the D (P =
1.0000), f (P = 0.1563), and ADC values (P = 0.3435). The Az values for
diagnosing the degree of hepatic fibrosis were as follows (D* value vs. MRE):
group B, 0.9649 vs. 0.9801 (p = 0.3741); group C, 0.9606 vs. 0.9871 (P =
0.1765).
Conclusion
As hepatic fibrosis progresses, the hepatic perfusion reduced,
and was effectively detected by IVIM imaging. IVIM is reliable technique for
evaluating hepatic fibrosis as well as MRE.
S213
BA C D E F G
Friday
B-0360 10:39
Utility of hepatobiliary phase in the Gd-EOB-DTPA-enhanced MR imaging
in the differentiation of simple steatosis and nonalcoholic steatohepatitis.
M. Takechi, T. Tsuda, G. Koiwahara, H. Tanaka, T. Mochizuki; Ehime/JP
Purpose: To evaluate the utility of hepatobiliary phase in the gadolinium
ethoxybenzyl diethylenetriaminepentaacetic acid-enhanced MR imaging (EOB-
MRI) in differentiating SS (simple steatosis) from NASH (nonalcoholic
steatohepatitis).
Methods
and Materials: From August 2009 to March 2013, histologically
proven 27 patients (11 SS and 16 NASH) who underwent both EOB-MRI and
in-phase/out-of-phase imaging were enrolled. The liver-to-spleen contrast ratio
(L/S ratio = signal intensity of the hepa tic parenchyma/signal intensity of the
spleen) and liver-to-muscle signal intensity ratio (LMSIR = signal intensity of
the hepatic parenchyma / signal intensity of the paraspinal muscle) were
calculated in the hepatobiliary phase of EOB-MRI, signal intensity loss on out-
of-phase T1-weighted images (fat fraction), which were compared between SS
and NASH groups. The correlations between histological stage/grade and L/S
ratio or LMSIR were explored.
Results
The L/S ratio and LMSIR in NASH were significantly lower than those
in SS (p = 0.01, 0.008). There was no difference in fat fraction between SS and
NASH groups (p = 0.767). In SS and NASH groups, the L/S ratio (r = -0.515, p
= 0.007) and LMSIR (r = -0.476, p = 0.014) were significantly correlated with
the fibrosis stage. Fat fraction in NASH was strongly correlated with the
steatosis score (p < 0.0001, r = 0.876).
Conclusion
In SS and NASH groups, the L/S ratio and LMSIR in the
hepatobiliary phase of EOB-MRI were useful imaging markers to differentiate
SS from NASH, showing significant association with fibrosis stage.
B-0361 10:48
Effect of extended delay time on the degree of liver enhancement on Gd-
EOB-DTPA-enhanced MRI in patients with parenchymal liver disease
Y. Esterson, M. Flusberg, S. Oh, F. Mazzariol, A.M. Rozenblit, V. Chernyak;
Bronx, NY/US (
[email protected])
Purpose: To compare hepatic parenchymal enhancement on the hepatobiliary
phase (HBP) obtained at 20 vs 30 minutes delay in patients with parenchymal
liver disease (PLD).
Methods
and Materials: This retrospective study included subjects with PLD
who underwent Gd-EOB-DTPA-enhanced MRI of abdomen from May until
August 2013, where HBP was obtained at both 20 and 30 minutes delay. For
each case, presence of biliary opacification with Gd-EOB-DTPA and signal
intensity (SI) of the liver, main portal vein (PV) and spleen were recorded on
pre-contrast, 20 and 30 minutes HBP. The following indices were calculated for
both 20 and 30 minutes HBP: liver relative enhancement (LRE) = (SI
HBP -
SIpre)/SIpre, liver/spleen index (LSI) = (SI liver/SIspleen)HBP/(SIliver/SIspleen)pre, liver/PV
index (LPI) = (SIliver/SIPV) HBP/(SIliver/SIPV)pre.
Results
There were 64 subjects, 34 (53.1%) men, mean age 58.8 years
(±11.7), median MELD score 40.9 (IQR 9.0 - 44.9). Biliary opacification was
present in 56 (87.5%) of 64 subjects on 20 minutes HBP and in 62 (96.9%) of
64 subjects on 30 minutes HBP (p < 0.05). Mean LRE were 0.46 ( ±0.3) at
20 minutes and 0.48 (± 0.3) at 30 minutes, p < 0.03. Mean LSI were 1.27 (±0.3)
at 20 minutes and 1.35 ( ±0.4) at 30 minutes, p < 0.0001. Mean LPI were 1.11
(±0.4) at 20 minutes and 1.18 (±0.4) at 30 minutes, p < 0.0001.
Conclusion
Extending delay time of HBP to 30 minutes improves degree of
liver enhancement and rate of biliary opacification in patients with PLD.
B-0363 10:57
Success rate of three MRI protocols for liver iron measurements
J.H. Runge, E.M. Akkerman, A.J. Nederveen, J. Stoker; Amsterdam/NL
(
[email protected])
Purpose: Several MRI-methods with particular benefits and drawbacks are in
use for measuring liver iron concentration (LIC). Examples include MR-
relaxometry (R2 and R2*) and the Gandon-method. We assessed the success
rate of these three methods.
Methods
and Materials: All patients undergoing LIC-measurements in our
centre between January 2008 and December 2012 were retrospectively
included. LIC-measurements consisted of the Gandon-, R2- and R2*-methods.
Regions-of-interest were drawn by one observer. R2 and R2* were calculated
using bi- and monoexponential signal decay functions, respectively. Rician
noise bias was approximated by the pythagorean addition of an extra fit
parameter to these functions. Gandon-data were converted online to a LIC-
value in mol/g, which has an upper detection limit of 340 mol/g. All iron
levels above this limit are given as > 350 mol/g. The relationships between
Methods
were assessed with Spearman's correlation coefficient (r
s).
Results
A total of 122 LIC-measurements were performed in 99 patients.
Gandon-, R2*- and R2-data were successfully acquired in 90/99 (91%), 98/99
(99%) and 59/99 (60%) baseline measurements, respectively. Correlations r
s
between Gandon-R2*, Gandon-R2 and R2*-R2 for LIC < 350 mol/g were near
perfect at 0.97 (P < 0.001, n=77), 0.88 (P < 0.001, n=47) and 0.91 (P 350 mol/g in 14 subjects. For these R2* and
R2 correlated at rs=0.73 (P=0.04, n=8).
Conclusion
Our data suggest that the Gandon- and R2*-methods are
preferable over the R2-method for LIC-measurement in terms of success rate.
Given that R2* is also sensitive for iron detection in subjects with LIC > 350
mol/g, R2* seems the method of choice.
B-0364 11:06
The role of iron in elevation of liver enzyme levels in steatosis: a non-
invasive assessment in general population by magnetic resonance
imaging
A. Radmard, M. Dadgostar, A. Yoonessi, A. Hashemi Taheri, H. Poustchi,
S. Merat, R. Malekzadeh; Tehran/IR (
[email protected])
Purpose: To investigate whether hepatic iron content can affect liver enzyme
levels in subjects with non-alcoholic fatty liver disease (NAFLD) and non-
alcoholic steatohepatitis (NASH) using non-invasive assessment by MRI.
Methods
and Materials: The study was carried out on 207 subjects randomly
selected from general population, aged 50-77 years, who underwent liver MRI
including in-phase/opposed-phase and multiechoT2*-weighted sequences.
Diagnosis of steatosis was made by a combination of ultrasound and MRI.
Quantitative T2*maps of entire cross-sectional area of liver was calculated on a
pixel-by-pixel basis using a semi-automated software to measure meanT2* of
whole liver.
Results
The mean T2*values were significantly lower in fatty liver group
compared with normal individuals (p=0.02). Male subjects with NASH had
statistically lower T2* than NAFLD group in multivariate analysis (OR 0.71,
95% CI 0.53-0.95), while this was not demonstrated in female subjects. Unlike
women, there was negative significant correlation between ALT level and
T2*values in men with NASH and NAFLD (r=-0.77vs. r=-0.45, respectively).
Every 1 IU/ml increment in ALT was associated with 9.07 milliseconds
decrease in T2* (95% CI, 3.8-14.3, p=0.003) in men with NASH.
Conclusion
Estimated hepatic iron content in MRI is directly correlated with
liver enzyme level in men, which may support the role of iron in possible
progression to NASH in simple steatosis. In contrast, lack of such correlation in
women could be attributed to relatively lower liver iron storage.
B-0365 11:15
Accuracy of liver fat quantification by CT, MRI and US: a prospective
comparison with magnetic resonance spectroscopy (MRS)
H. Kramer
1, P.J. Pickhardt2, M.A. Kliewer2, D. Hernando2, G.-H. Chen2,
S.B. Reeder2; 1Munich/DE, 2Madison, WI/US (
[email protected])
Purpose: The hallmark feature of non-alcoholic fatty liver disease (NAFLD) is
the accumulation of triglycerides within hepatocytes (steatosis), which causes
inflammation, fibrosis, and cirrhosis. MR-spectroscopy (MRS) is regarded as
the non-invasive standard for quantification of tissue triglycerides. The purpose
of this study was to evaluate the accuracy of quantitative chemical shift-
encoded MRI, dual-energy CT (DECT) and ultrasound (US) to quantify
steatosis.
Methods
and Materials: 25 patients (56 ±5 years, 10m/15f) scheduled for CT-
colonography (CTC) were recruited. All underwent CTC, MRS, MRI and US
within 2 hours. 3 MRS voxels were placed throughout the liver; DECT, MRI and
US measurements were subsequently co-localised. For CT, Hounsfield Units
(HU) as well as fat density (FD) derived from DECT were recorded. For MRI,
proton density fat-fraction (PDFF) measured from the chemical shift-encoded
Method
(IDEAL-IQ), and for US, shear-wave velocity, SNR and attenuation
were recorded. Data were analysed using linear regression for each technique
compared to MRS. 2-sided Student t-tests (0.05 significance level) were used
with the hypothesis that the slope coefficient is zero.
Results
There was excellent correlation between MRS-PDFF vs MRI-PDFF
(r
2=90.57-98.46, p < 0.05) and CT-HU (r 2=89.97-92.38, p < 0.05). CT-FD
showed moderate correlation with MRS-PDFF (r 2=50.75-59.14, p < 0.05). None
of the US based metrics showed reliable correlation with MRS-PDFF
(r2 0.05).
Conclusion
We evaluated different non-invasive modalities to serve as
biomarkers for evaluation of NAFLD. Quantitative chemical shift MRI-PDFF
and CT-HU showed excellent correlation to MRS-PDFF. Material
decomposition with DECT (CT-FD) did not improve the accuracy of fat
quantification. US was not accurate for liver-fat quantification.
Author Disclosures:
H. Kramer: Grant Recipient; UW Madison Radiology R&D. P.J. Pickhardt:
Grant Recipient; NIH. Research/Grant Support; NIH. M.A. Kliewer:
Research/Grant Support; NIH. D. Hernando: Research/Grant Support; NIH. G.
Chen: Research/Grant Support; NIH. S.B. Reeder: Grant Recipient; NIH.
Research/Grant Support; Bracco Diagnostics.
S214
BA C D E F G
Friday
B-0366 11:24
Comparison of modified dixon-sequences and H1-spectroscopy for
quantitative assessment of liver steatosis in patients with gestational
diabetes
N.N. Kammer, C. Lütke Daldrup, E. Coppenrath, A. Lechner, U. Ferrari,
M.F. Reiser, S. Wirth, T. Saam, H. Hetterich;
Munich/DE (
[email protected])
Purpose: Patients with gestational diabetes have a substantial increased risk
for the development of type-2 diabetes. Liver steatosis has been identified as
an independent risk factor for diabetes. H1-spectroscopy is an established
Method
to measure liver fat content but is restricted to small voxel elements,
long acquisition time and complicated post-processing. Fast-modified Dixon
sequences (mDixon) have been shown to be an alternative for liver fat
assessment. Aim of this study was to compare mDixon with H1-spectroscopy
for quantitative assessment of liver fat content.
Methods
and Materials: Patients with a history of gestational diabetes within
the last 6 months underwent both H1-spectroscopy (STEAM, TE 10 ms, TR
2000 ms, FA 90, voxel size 1.5x1.5x1.5 cm³) placed in segment VII of the liver
and mDixon imaging (TE first 1.5 ms/second 2.7 ms, TR 4.1 ms, FA 10) at a 3
Tesla scanner.
Results
54 patients (mean age 28.5 ±4.1 years, mean BMI 27 ±3.7) were
included. H1-spectroscopy (average acquisition time 8 minutes) and mDixon
sequences (average acquisition time 30 seconds) were successfully
performed. Liver fat content was significantly higher in the mDixon sequences
compared to H1-spectroscopy (5.1 ±6.5% vs. 2.4 ±5.7%, p < 0.001). Correlation
between both techniques was excellent (Pearsons' R 0.96). Inter-reader
agreement was excellent for both acquisition techniques, with an intraclass-
correlation coefficient of 0.97 and 0.96, respectively.
Conclusion
This study demonstrated an excellent correlation between
mDixon and H1-spectroscopy for measurements of liver fat content. However,
absolute values are higher with the mDixon sequence. Other fat compartments
such as abdominal fat can also be assessed by mDixon within the same
sequence.
B-0367 11:33
Are MR diffusion-weighted, hepato-specific contrast-enhanced and
susceptibility-weighted imaging surrogate markers for advanced liver
fibrosis detection in chronic liver disease patients?
D.S. Feier
1, C. Balassy2, N. Bastati2, A. Ba-Ssalamah2; 1Cluj-Napoca/RO,
2Vienna/AT (
[email protected])
Purpose: To assess whether apparent diffusion coefficients (ADC) using
diffusion-weighted imaging (DWI), signal intensity measurements on
susceptibility-weighted imagines (SWI), and measurements of gadoxetic acid-
enhanced liver parenchyma intensity correlate with histologically proven
fibrosis, and to compare their diagnosti c value as non-invasive methods for
liver fibrosis staging.
Methods
and Materials: Seventy-six patients underwent a 3 T MRI
examination [including DWI, gadoxetic acid-enhanced T1-weighted MRI, and
SWI sequences] and liver biopsy. Fibrosis was staged using the Metavir
scoring system: F0 (n=17, 21.2%); F1 (n=10, 12.5%); F2 (n=12, 15%); F3
(n=11, 13%); and F4 (n=26, 37.5%). Signal intensity (SI) of the liver was
defined using region-of-interest measurements to calculate the mean ADC
values, the relative enhancement (RE) in the hepatobiliary phase (20 minutes
after gadoxetic acid administration), and the liver to muscle ratio (LMR)
measurements for SWI. The diagnostic performance of the three parameters
for distinguishing F0-F2 (no to moderate fibrosis) from F3-F4 (severe fibrosis)
was assessed using receiver operating characteristics (ROC) analysis.
Results
Liver fibrosis correlated strongly with SWI LMR (r=-80, p < 0.0001)
and moderately with RE (r=-61, p < 0.000) and mean ADC (-0.58, p < 0.0001).
The best diagnostic performance in detecting severe liver fibrosis was obtained
for LMR SWI measurements, with an AUROC of 0.90 (Se=98%, Sp=69.4%).
RE measurements and DWI performed comparably, with an AUROC of 0.85
(Se=88.2%, Sp=91.3%), and 0.77 (Se=67.3%, Sp=85.7%), respectively.
Conclusion
The diagnostic performance of DWI, gadoxetic acid-enhanced
MRI, and SWI to identify patients with severe liver fibrosis was comparable in
our cohort, but the AUROC values favour SWI as the best diagnostic modality.
B-0368 11:42
Comparison of mDixon sequences and T1-weighted images in the
determination and quantification of adipose tissue compartments with
whole-body 3 T-MRI
H. Hetterich, C. Lütke Daldrup, E. Coppenrath, A. Lechner, U. Ferrari, S. Wirth,
T. Saam, N.N. Kammer; Munich/DE (
[email protected])
Purpose: T1-weighted (T1w) images can quantify fat distribution patterns,
which have a predictive value for the development of chronic diseases like
type-2 diabetes. Modified Dixon sequence (mDixon) can generate fat only
images with high contrast between fat and lean tissue. Aim of this study was to
evaluate mDixon for assessment of fat-distribution in whole-body MRI using
T1w as reference standard.
Methods
and Materials: Ten healthy volunteers (6 female; age: 24 ±3 years;
BMI 22.3±3.8) had a whole-body MRI at 3 Tesla using axial T1w and mDixon
sequences. Bodies were divided into five anatomic regions (upper extremity,
head/neck, thorax, abdomen, lower extremity) and subcutaneous, visceral and
whole body fat was determined using a dedicated software analysis tool.
Image quality and image contrast, specifically the ability to differentiate fat from
surrounding tissue, were assessed using a visual analogue scale from 1-5
(VAS, 5=best).
Results
50 anatomical regions were evaluated in each sequence. There was
no significant difference in relative total body and relative visceral fat content in
mDixon and T1w (total: 30.7 ±6.4% vs. 30.7 ±6.3%, p=1.0, visceral: 6.6 ±2.7%
vs. 6.7± 3.1%, p=0.82). All measurements showed an excellent correlation
(total: Pearson's R=0.99 for total and R=0.88 for visceral body fat). The VAS
displayed a significant better image quality and contrast of the mDixon both for
subcutaneous (3.6 ±0.5 vs. 4.3 ±0.6, p=0.001) and visceral fat (3.0± 0.0 vs.
4.7±0.5 > p=0.001).
Conclusion
mDixon provides better tissue contras t for the quantification of
adipose tissue compared to conventional T1w and quantitative results do not
differ significantly between these two sequences.
10:30 - 12:00 Room N/O
Vascular
SS 515
Developments in MR imaging
Moderators:
D. Brisbois; Liege/BE
R.N. Planken; Amsterdam/NL
B-0369 10:30
Non-contrast-enhanced quiescent interval single-shot MR angiography at
3 Tesla in patients with advanced peripheral arterial occlusive disease
K.M. Thierfelder1, G. Meimarakis1, K. Nikolaou1, W.H. Sommer1, P. Schmitt2,
M.F. Reiser1, D. Theisen1; 1Munich/DE,
2Erlangen/DE (
[email protected])
Purpose: The aim of this study was to assess the diagnostic performance of
non-contrast-enhanced ECG-gated quiescent interval single-shot (QISS)
magnetic resonance angiography at 3 Tesla in patients with advanced
peripheral arterial occlusive disease (PAOD).
Methods
and Materials: A total of 21 consecutive patients with advanced
PAOD (Fontaine stage IIb and higher) referred for peripheral magnetic
resonance angiography (MRA) were included. Imaging was performed on a 3 T
whole body MR scanner. Image quality and stenosis diameter were evaluated
in comparison to contrast-enhanced continuous table and TWIST MRA (CE-
MRA) as standard of reference. QISS images were acquired with a thickness
of 1.5 mm each (high-resolution QISS, HR-QISS). Two blinded readers rated
the image quality and the degree of stenosis for both HR-QISS and CE-MRA in
26 predefined arterial vessel segments on 5-point Likert scales.
Results
With CE-MRA as the reference standard, HR-QISS showed high
sensitivity (94.1%), specificity (97.8%), positive (95.1%), and negative
predictive value (97.2%) for the detection of significant ( 50%) stenosis.
Interreader agreement for stenosis assessment of both HR-QISS and CE-MRA
was excellent ( 5-values of 0.951 and 0.962, respectively). As compared to CR-
MRA, image quality of HR-QISS was significantly lower for the distal aorta, the
femoral and iliac arteries (each with p < 0.01), while no significant difference
was found in the popliteal (p = 0.09) and lower leg arteries (p = 0.78).
Conclusion
Non-enhanced ECG-gated HR-QISS performs very well in
subjects with severe PAOD and is a good alternative for patients with a high
risk of nephrogenic systemic fibrosis.
B-0370 10:39
Magnetic particle imaging (MPI): direct quantification of vascular stenosis
J. Haegele1, J. Rahmer2, R.L. Duschka1, C. Schaecke1, N. Panagiotopoulos1,
J. Tonak1, J. Borgert2, J. Barkhausen1, F.M. Vogt1; 1Lübeck/DE,
2Hamburg/DE (
[email protected])
Purpose: Purpose of this study was to visualise and quantify different vascular
stenoses using Magnetic Particle Imaging (MPI).
Methods
and Materials: Nine standardised stenosis-phantoms were used,
each featuring a circular lumen of 10 mm diameter. The lumen narrowed
conically to different circular stenose s of 1 mm diameter amounting to 99% of
the cross section, 2 mm/96%, 3 mm/91%, 4 mm/84%, 5 mm/75%, 6 mm/64%,
7 mm/51%, 8 mm/36% or 9 mm/19%, respectively. For MPI, the phantoms
were filled with a dilution of 5% Resovist (Bayer Pharma). Images were
acquired using a pre-clinical MPI-demonstrator (Philips Research, Hamburg,
S215
BA C D E F G
Friday
Germany). For comparison, the same stenosis-phantoms were evaluated with
contrast-enhanced CT and MRI (Siemens Definition AS64, 12% Imeron 300
(Bracco Imaging); Philips Achieva 1.5 T, 3% Gadovist (Bayer Vital)).
Results
MPI was able to visualise all stenoses accurately but the highest
(1 mm/99%; spatial resolution of about 1x3x3 mm^3). CT exhibited the highest
spatial resolution, followed by MRI, both modalities were able to visualise all
stenoses. MPI was able to detect the residual lumen of the 1 mm/99% stenosis
using signal quantific ation. Furthermore, it was possible to reliably quantify the
extent of the stenoses down to 5 mm/75%. Higher grade stenoses were
underestimated, the stenosis of 84% was measured as 75%, 91% as 79%,
96% as 81% and 99% as 90%.
Conclusion
Direct quantification of vascular stenoses using MPI is possible.
In current experimental MPI-systems, signal interferences can aggravate the
MPI-signal of smaller objects, thus distorti ng their quantification. However, MPI
is still able to detect small structures like residual lumina in high grade vascular
stenosis using the raw MPI-signal.
Author Disclosures:
J. Rahmer: Employee; Philips Research.
B-0371 10:48
High-resolution TOF MRA at 7T versus DSA for assessment of
arteriovenous malformations
L. Umutlu, K. Wrede, C. Moenninghoff, P. Dammann, S. Johst, M. Forsting,
M. Schlamann; Essen/DE (
[email protected])
Purpose: The aim of this trial was to compare the diagnostic competence of
high-resolution 7 Tesla TOF MRA with digital subtraction angiography (DSA)
for assessment of AVM.
Methods
and Materials: 15 patients with known AVM prospectively underwent
pretreatment DSA and a 7 Tesla MRA (Magnetom 7T, Siemens Healthcare)
obtaining a high-resolution Time-of-flight MRA (voxel size of 0.2 x 0.2 x
0.2 mm3). Two readers in consensus evaluated the delineation of the AVM (1)
nidus, (2) feeder, (3) drainer, and (4) relationship between AVM and the
adjacent brain structures (5) vessel-tissue contrast as well as (6) artifact
impairment for both datasets using a 5-point scoring system.
Results
Both imaging modalities provided high-quality vessel delineation.
DSA yielded excellent ratings for assessment of AVM related features (e.g.
mean nidus 4.7; mean feeder vessel 4.9). 7T TOF MRA approached equally
high scoring for evaluation of AVM related items (mean nidus 4.6; mean feeder
vessel 4.8). Furthermore, 7T TOF MRA allowed for assessment of the
relationship between AVM and adjacent brain structures. Only minor
impairments due to signal variations were noted for MR imaging (mean 4.5).
Conclusion
Based on the increased spatial resolution and high-quality
vessel-tissue contrast, ultra-high-field TOF MRA enables superior assessment
of AVM and its associated vessel structures.
B-0372 10:57
Non-contrast-enhanced T1w MRA of the lower extremity vessels at 7
Tesla
A. Fischer, S. Maderwald, S. Johst, S. Orzada, M.E. Ladd, K. Nassenstein,
T.C. Lauenstein, L. Umutlu; Essen/DE (
[email protected])
Purpose: Investigation of the feasibility of non-contrast-enhanced (NE) T1-
weighted MRA of the lower extremity arteries at 7 Tesla (T) and comparison to
contrast-enhanced (CE) MRA at 1.5 T.
Methods
and Materials: 12 healthy volunteers were examined on a 7T whole-
body MR-system utilising a custom-built 16-channel transmit/receive coil and a
manually positionable AngioSURF table for multi-station imaging. T1w NE-
Turbo-FLASH imaging with phonocardiogram gating was acquired covering the
vasculature from pelvis to feet. 7 subjects underwent a concomitant ce-MRA at
1.5 T (1M-gadobutrol 0.1 mmol/kg BW). Qualitative image analysis and
presence of artifacts were assessed using a five-point scale in the (1) iliacal,
(2) femoral, (3) popliteal, (4) tibiofibular and (5) foot segment. Contrast-ratios
(CR) of the analysed arterial segments and adjacent soft tissue were obtained
for quantitative assessment.
Results
Both MRA techniques provided an overall high-quality conspicuity of
the arterial vasculature, with 7T Turbo-FLASH imaging yielding a
homogeneously hyperintense delineation of the non-enhanced arteries. While
7T NE-MRA showed slight artifact impairment in all assessed arterial segments
(e.g. iliacal 4.21, feet 4.6), 1.5 T ce-MRA only showed focal minor impairment
of the foot segment (4.7). Quantitative analysis revealed equivalent contrast
ratios for most assessed segments in both MRA techniques, with superior
mean values for 1.5 T ce-MRA for the iliacal (NE-7T 0.50, ce-1.5 T 0.86) and
femoral (NE-7T 0.66, CE-1.5 T 0.78) arteries.
Conclusion
Our results demonstrate high-quality imaging of the lower
extremity arteries with 7 Tesla non-contrast-enhanced T1w MRA, yielding
comparable image quality to 1.5 T CE-MRA.
Author Disclosures:
L. Umutlu: Consultant; Bayer AG.
B-0373 11:06
Non-enhanced T1-weighted imaging of the visceral arteries at 7 Tesla
A. Fischer, O. Kraff, S. Maderwald, K. Beiderwellen, T.C. Lauenstein,
L. Umutlu; Essen/DE (
[email protected])
Purpose: Aim of the study was to assess the feasibility of different non-
contrast-enhanced T1-weighted (w) sequences for imaging of the visceral
arteries of the upper abdomen at 7 Tesla.
Methods
and Materials: 10 healthy volunteers were examined on a 7T whole-
body MR-system utilising a custom-built 8-channel transmit/receive coil. The
following non-enhanced sequences were acquired: T1w 2D_FLASH, T1w
3D_FLASH and Time of flight (TOF)-MRA in transversal orientation. The
delineation of the following visceral arteries was evaluated: right and left
common hepatic artery, coeliacal and splenic artery, superior and inferior
mesenteric artery. For qualitative analysis, image quality and the presence of
artifacts were assessed using a five-point scale. Contrast ratios of the above
named arteries in correlation to adjacent liver tissue or psoas muscle were
calculated for quantitative assessment.
Results
All three sequences provided a homogenous hyperintense
delineation of the assessed visceral arteries. TOF-MRA provided best overall
image quality (TOF 4.17, 2D_FLASH 3.42, 3D_FLASH 3.46) and highest mean
values for image quality for all analysed vessel segments as well as least
impairment due to artifacts (overall artifacts TOF 4.08, 2D_FLASH 3.50,
3D_FLASH 3.46). Quantitative image analysis confirmed the superiority of the
TOF sequence showing significant higher CR values for all visceral arteries
due to an effective suppression of background signal (e.g. right hepatic artery
TOF 4.25, 2D_FLASH 3.54, 3D_FLASH 3.33; p < 0.05).
Conclusion
Non-contrast-enhanced T1w imaging in general and, TOF-MRA
in particular, appear to be promising techniques for good quality assessment of
visceral arteries without the need of contrast media at 7T.
Author Disclosures:
L. Umutlu: Consultant; Bayer AG.
B-0374 11:15
Contrast enhanced MR angiography of renal arteries in living kidney
donors - comparison with CT-angiography
K. Sulkowska, P. Palczewski, M. Sawicka, M. Golebiowski; Warsaw/PL
(
[email protected])
Purpose: CT angiography (CTA) is regarded the gold standard in noninvasive
assessment of abdominal arteries, however it has a burden of ionizing
radiation. The purpose of our study was to assess the quality of images of
renal arteries in living kidney donors acquired with MR angiography (MRA) and
compare them with CTA.
Methods
and Materials: 40 potential living kidney donors were examined.
CTA was performed on a 64-row scanner (Aquilion, Toshiba, Japan). 150 ml of
contrast medium was administered in a triphasic automatic injection. MRA was
performed on 1.5 T unit (Ingenia, Philips, The Netherlands). Contrast medium
in a dose of 0.2 ml/kg body weight was injected at a rate of 2 ml/s. The MRA
images were acquired with T1 3D sequence. The number and size of renal
arteries were assessed in both studies. The quality of renal artery images in
MRA was assessed with a four-point scale (very good, good, bad, vessel not
visualised).
Results
CTA showed 108 arteries supplying 80 kidneys. In MRA, 107 arteries
were visualised - one 2 mm extra artery was not detected. The quality of
images was very good in 93 cases (87%), good in 8 (7.5%), and bad in 6
(5.5%). Features of fibromuscular dysplasia were not detected in one artery in
MRA. In 45% of arteries, 1-2 mm underestimation of diameter occurred in
MRA. In the remaining cases, the measurements were concordant.
Conclusion
MRA shows a good agreement with CTA, however
underestimation of arterial diameter may lead to serious discrepancies in
selected cases.
B-0375 11:24
Contrast paramagnetic enhancement of coronary atherosclerotic lesions
as extension of CE-MRI of the heart
W.Y. Ussov, E.E. Bobrikova, E.A. Vusik, A.A. Bogunetsky, P.I. Lukyanenok,
S.G. Goltsov; Tomsk/RU (
[email protected])
Purpose: We evaluated the CE-MR imaging of atherosclerotic plaques in
patients with coronary atherosclerosis and recent myocardial infarction.
Methods
and Materials: 22 patients with verified coronary atherosclerosis
were studied, 10 with predominantly right coronary artery disease and 12 with
stenosis of the left circumflex coronary artery. The CE MRI study of the heart
was carried out using T1-w scan with end-diastolic ECG gating obtaining 7 mm
slices of the whole heart. TR was 450 ms, TE = 15 ms, matrix 256 E 256, with
voxel 0.1 _ 0.12 mm. Paramagnetic was injected as 2 ml of 0.5 M solution per
10 kg of BW. For the atherosclerotic plaque itself and arterial wall outside the S216
BA C D E F G
Friday
plaque, the index of image enhancement was calculated as ratio of intensities
on T1-w.SE scan.
Results
When analysed visually the T1-w CE-MR scan provided sure
delineation of stenoses of coronary arteries due to uptake of paramagnetics to
the plaque. In patients of control group, the RCA IE was 1.08 ± 0.06, and LCA
IE 1.09 ± 0.07. The atherosclerotic plaque in infarction-dependent LCA
demonstrated IE as high as 1.54 ± 0.22, whereas in infarction-dependent LCA
the plaque was enhanced with IE=1.42 ± 0.18. Also the areas of infarction-
dependent arteries far from plaques demonstrated mild enhancement with IE in
ranges 1.16-1.18. No significant correlation was revealed between IE and
degree of stenoses or LV contractility indices.
Conclusion
CE-MRI of coronary atherosclerotic plaques can be suggested as
addition to CE myocardial studies for better depiction of atherosclerosis.
B-0376 11:33
3D non-contrast-enhanced, ECG-gated MR angiography of the lower
extremities at 3.0 T: comparison with contrast-enhanced MR angiography
M. Rasper, M. Wildgruber, M. Settles, H.-H. Eckstein, C. Reeps,
A. Zimmermann, E.J. Rummeny, A. Huber;
Munich/DE (
[email protected])
Purpose: To determine objective and subjective image quality and diagnostic
confidence of non-contrast-enhanced ECG-gated MR angiography (NE-MRA)
of the lower extremities compared to gadolinium-enhanced MR angiography
(CE-MRA) at 3.0 Tesla.
Methods
and Materials: 27 patients with PAOD underwent multistep, ECG-
gated 3D T2-weighted TSE NE-MRA (TRANCE, TR=1000 ms, TE=75 ms,
voxel size 1.7x1.7x4 mm). Systolic and diastolic datasets were acquired after
individual planning of the diastolic acquisition window. After subtraction, MIP
projections were calculated. CE-MRA was performed within the same
examination at a 3.0 T MR system (Ingenia, Philips). CNR was determined for
the iliacal, femoral and popliteal arteries. Subjective image quality (5-point-
scale), sensitivity and specificity for detection of arterial stenoses and
occlusions (1: no stenosis, 2: 1-49%, 3: 50-74%, 4: 75-99%, 5: occlusion) was
determined.
Results
CNR was 25.7 ± 1.4 for NE-MRA and 28.4 ± 1.6 for CE-MRA (p=ns).
Subjective image quality was 4.4 ± 0.1 vs. 4.7 ± 0.1 for NE-MRA and CE-MRA
(p=ns). Lesions (grade 3-5) were detected with a sensitivity and specificity of
98.4% and 93.4% compared to CE MRA. The degree of stenosis was
overestimated in 24.7% and underestimated in 3.5% by NE-MRA.
Conclusion
NE-MRA of the lower extremities at 3.0 T is a promising method
in patients with severe renal dysfunction (risk of nephrogenic systemic fibrosis).
Although providing slightly inferior subjective image quality and a lower CNR
compared to CE-MRA, NE-MRA (TRANCE) offers an alternative MR
angiography method for patients with PAOD and renal failure with acceptable
high diagnostic accuracy.
B-0377 11:42
7T vs 1.5 T TOF MRA for assessment of intracranial aneurysms: the more
Tesla, the better?
L. Umutlu, K. Wrede, C. Moenninghoff, S. Johst, P. Dammann, M. Forsting,
M. Schlamann; Essen/DE (
[email protected])
Purpose: Aim of this trial was to compare the diagnostic ability of 1.5 versus 7
Tesla TOF MRA for assessment of intracranial aneuryms.
Methods
and Materials: 17 subjects were examined on a 1.5 Tesla
(Magnetom Aera, Siemens Healthcare) and Time-of-flight MRA with a voxel
size of 0.7x0.7x0.7 mm3 was obtained. Subsequently all subjects underwent a
7 Tesla examination (7T whole-body MR system; Magnetom 7T, Siemens
Healthcare) with a voxel size of 0.2 x 0.2 x 0.2 mm3. Two radiologists in
consensus assessed the delineation of the (1) aneurym dome, (2) neck, (3)
parent vessel, (4) vessel tissue contrast and (5) image impairment due to
artifacts. For qualitative analysis a 5-point scale was used (5= excellent
delineation; 1= non-diagnostic). Contrast ratios (CR) of all aneurysms and
adjacent parenchyma were calculated. A Wilcoxon rank test was performed for
analysis of statistical significance.
Results
According to qualitative analysis 7 Tesla TOF MRA yielded
significantly superior delineation of dome (mean 7T:=4.5; mean 1.5 T= 3.2;
p < 0.5) and neck (mean 7T=4.6; mean 1.5 T=3.3; p <.05) over 1.5 MRA.
Based on increased signal alterations, 7T MRA showed slightly decreased CR
of aneuryms to adjacent parenchyma (mean 0.60) over 1.5 MRA (CR mean
0.66; p < 0.05), also reflected in increased image impairment of subjective
ratings (mean 7T=3.8; mean 1.5 T=4.5).
Conclusion
High-resolution 7T TOF MRA may bear the potential to provide
superior assessment of the aneurysms and their related vessel-features based
on high-quality vessel-tissue contrast and imaging at improved spatial
resolution.
B-0378 11:51
Whole brain 3D-black-blood 3 T-MRI for the diagnosis of CNS vasculitis: a
feasibility study
N.N. Kammer1, E. Coppenrath1, H. Kooijman2, M.F. Reiser1, T. Saam1;
1Munich/DE, 2Hamburg/DE (
[email protected])
Purpose: Although 2D-T1w black-blood sequences are able to detect
atherosclerotic and inflammatory changes of intracranial vessels they are time
extensive and thus limited to a small field-of- view. We sought to evaluate a
commercially not available isotropic 3D whole-brain-black-blood T1w-TSE
sequence with variable flip angles (3D-BB-VISTA) for the diagnosis of cerebral
vasculitis.
Methods
and Materials: 10 patients with suspected vasculitis and 15 tumor
patients without any evidence of vascular disease received a standardised
protocol (T1w pre- and post contrast, TOF, DIFF, T2, FLAIR) and a T1w 3D-
BB-VISTA sequence pre- and post contrast (resolution=0.8 mm isotropic, scan-
time 4:56 minutes). Left and right arteries of the anterior and posterior
circulation (100 arterial segments) were evaluated by two experienced readers
in consensus decision for the presence of stenosis and contrast enhancement
of the vessel wall.
Results
3 out of 40 (7.5%) arterial segments in patients with suspected
vasculitis showed focal contrast enhancement and luminal narrowing (1x left
vertebral artery, 2x left middle cerebral artery). These findings were found in
three distinct patients in which vasculitis was clinically confirmed. One patient
with sickle-cell disease had a stenosis and concentric wall thickening without
contrast enhancement. None of the 60 arterial segments of the tumor patients
showed any signs of contrast enhancement or luminal narrowing.
Conclusion
Whole-brain-black-blood MRI is feasible in less than 10 minutes
scan time and allows to accurately diagnosing CNS vasculitis. Future studies
will be necessary to evaluate the utility of this sequence for other vascular
pathologies, such as arterial dissection and atherosclerosis.
10:30 - 12:00 Conf. Room M3
Interventional Radiology
SS 509
Transarterial chemoembolisation (TACE)
Moderators:
K. Malagari; Athens/GR
K. Zelenak; Martin/SK
B-0379 10:30
Experimental study on transarterial administration of VEGF siRNA
combined with transarterial chemoembolisation in rats with
hepatocellular carcinoma
T.J. Vogl
1, J. Qian2, E. Oppermann1, U. Imlau1, A. Tran1, H. Korkusuz1,
W.O. Bechstein1; 1Frankfurt a. Main/DE, 2 Wuhan/CN
(
[email protected])
Purpose: To evaluate the effects of transarterial administration of vascular
endothelial growth factor siRNA (VEGF siRNA) combined with transarterial
chemoembolisation (TACE) vs. TACE alone for the treatment of hepatocellular
carcinoma (HCC) in rats.
Methods
and Materials: Subcapsular implantation of a solid Morris-hepatoma
3924 A in the liver was carried out in 20 male ACI rats (day 0). Tumor volume
(V1) was measured by MRI (day 12). After laparotomy and retrograde
placement of a catheter into the gastroduodenal artery, the following agents of
interventional treatment were injected into the hepatic artery (day 13): (A)
TACE (0.1 mg mitomycin+0.1 ml lipiodol+5.0 mg degradable starch
microspheres)+2.5nmol VEGF siRNA (n=10); (B) TACE alone (control group,
n=10). Tumor volume (V2) was assessed by MRI (day 25) and tumor growth
ratio (V2/V1) was calculated. Western blot analysis was performed to assess
the protein expression level of VEGF in each treatment. Quantization of
positive VEGF tumor cells was carried out by immunohistochemical
examination in all rats.
Results
The mean tumor growth ratios (V2/V1) were 1.2853 ±0.1568 in group
A (TACE+VEGF siRNA) and 3.0239 ±0.2098 in group B (TACE alone). Group A
showed significant inhibition of tumor growth ( P
< 0.01) compared with the
control group B. There were significant differences in VEGF expression levels
between group A and group B by Western blot analysis ( P < 0.01). Lower
expression of VEGF in HCC was observed in group A vs. group B by
immunohistochemical examination (P < 0.05).
Conclusion
Combined TACE and transarterial administration of VEGF siRNA
is more effective than TACE alone for growth inhibition of HCC in rats.
S217
BA C D E F G
Friday
B-0380 10:39
Importance of supply of right inferior phrenic artery to segment VIII
hepatocellular carcinoma for trans-arterial chemoembolisation
H. Saleem, A.I. Rana, M. Jehangir, E.M. Kiani; Islamabad/PK
(
[email protected])
Purpose: The purpose of the study is to evaluate arterial supply by the right
inferior phrenic artery (RIPA) of segment VIII hepatocellular carcinoma (HCC)
and its importance in trans-arterial chemoembolisation (TACE).
Methods
and Materials: From July 2011 to August 2013, 176 patients
underwent TACE for hepatocellular carcinoma. Pre- and post-
chemoembolisation liver dynamic studies done on 320-slice CT scanner and
digital subtraction angiograms were retrospectively reviewed for tumor location,
tumor feeding vessels, technical success of chemoembolisation and tumor
response based on Modified Response Evaluation Criteria In Solid Tumors
(mRECIST) guidelines.
Results
Segment VIII HCC was identified in 47 (26%) of 176 cases.
Chemoembolisation of RIPA was done in 18 (10%) cases, out of which 11
cases had HCC in segment VIII. In 3 out of these 11 cases, disease
progression was recognised on follow-up CT; therefore, on subsequent TACE
sessions chemoembolisation of RIPA was done after which they showed
complete or partial response on further follow-up. In rest of 36 cases of
segment VIII HCC, there was an indirect evidence of RIPA supplying segment
VIII HCC; in 3 cases, RIPA was not chemoembolised and progression of
disease was evident on follow-up, and furthermore 6 cases had CT evidence of
RIPA supplying segment VIII HCC when analysed retrospectively.
Conclusion
Routine selective chemoembolisation of right inferior phrenic
artery is necessary in all segment VIII hepatocellular carcinomas as significant
number (42%) of segment VIII HCC in our study had an evidence of additional
blood supply from right inferior phrenic artery.
B-0381 10:48
Utility of cone-beam computed tomography and Emboguide software for
planning and monitoring of transarterial catheter embolisation (TACE) of
hepatocellular carcinoma (HCC)
C. Floridi, G. Carrafiello, F. Fontana, A. Ierardi, C. Fugazzola; Varese/IT
(
[email protected])
Purpose: To prospectively evaluate the utility of C-arm cone-beam computer
tomography (CBCT) and Emboguide software for planning and monitoring of
transarterial catheter embolisation (TACE) of HCCs and report on feasibility
and short-term clinical outcome.
Methods
and Materials: Between November 2012 and September 2013, 35
patients (25 men, 10 women, mean age 76.4 years) underwent TACE of HCC
nodules (67 nodules, mean nodule size 27.5 mm). Intra-procedural dual-phase
CBCT (arterial and venous) after intra-arterial contrast administration was
performed to visualise the HCC nodules and to determine the nodule arterial
feeders using dedicated Emboguide software. TACE was performed with
doxorubicine mixed with lipiodol and non-enhanced CBCT was performed after
TACE. CBCT images acquired before and after TACE were registered to
evaluate drugs tumour filling. CBCT lesion detection accuracy, tumour arterial
feeders detection accuracy and number of catheter re-positioning on the basis
of CBCT and Emboguide software information were recorded. Clinical success
was measured as lack of enhancement on follow-up CT.
Results
All procedures were completed successfully without complications.
Intra-procedural C-arm CBCT detected of the 67 lesions (100%). The TACE
catheters were repositioned on the basis of CBCT and Emboguide software in
25 lesions (37.3%). Clinical success was achieved in 55 of the lesions (82.1%),
while 12 (17.9%) presented with local recurrence on follow-up imaging.
Conclusion
Planning and monitoring of HCC nodule TACE using C-arm
CBCT and Emboguide software is feasible and leads to establish the correct
HCC arterial feeders allowing to perform a selective TACE.
B-0382 10:57
Transcatheter intra-arterial MRA for accurate guidance of TACE in
patients with HCC
A. Massmann, M. Wolska-Krawczyk, R. Seidel, P. Fries, G.K. Schneider,
A. Buecker; Homburg a.d. Saar/DE (
[email protected])
Purpose: Evaluation of transcatheter intra-arterial MRA (TI-MRA) with
conventional digital subtraction angiography (DSA) for accurate guidance of
selective transarterial chemoembolisation (TACE) of hepatocellular carcinoma
(HCC).
Methods
and Materials: 26 patients with unresectable HCC underwent 57 TI-
MRA procedures. Prior to embolisation, a catheter was inserted into HCC
supplying sub-/segmental arteries under x-ray fluoroscopy-guidance. Contrast-
enhanced TI-MRA (20 ml Gadolinium-DOTA 5% Dotarem, Guerbet, France)
was performed using either FLASH3D- or VIBE-sequences (Siemens
Magnetom Aera 1.5 T) for acquisition of tumour perfusion. CT after
chemoembolisation by injection of lipiodol/doxorubicin from identical catheter
position was used to determine the perfused liver area, which was matched to
the area seen by TI-MRA.
Results
TI-MRA confirmed initial correct catheter positioning in 94% of
patients and led to catheter repositioning in three patients. One erroneous
adrenal gland embolisation and two embolisations of wrong liver-segments
were avoided. Additional collateral tumour supply was evident in four cases
because of incomplete perfusion of HCC in TI-MRA via a single catheter
position. Additionally, new HCC-nodules were identified; TI-MRA depicted two
patients with two satellite HCC-nodules, which were later visible in follow-up
staging MRI. Mean SNR for tumour depicted VIBE in arterial and venous
phase superior to FLASH3D (p < 0.02, resp. p < 0.01)]. CNR was statistically
not different.
Conclusion
TI-MRA proved beneficial to detect correct catheter positioning
and prevented erroneous/insufficient tumour embolisation. VIBE was
favourable to FLASH3D. Compared with an IR-angiosuite with DynaCT
functionality, TI-MRA lacks ionizing radiation exposure but requires time-
consuming patient transfer between IR/MRI unit.
B-0383 11:06
Caudate lobe hepatocellular carcinoma treated with selective
chemoembolisation: usefulness of C-arm CT performed at the proper
hepatic artery or equivalent
W. Choi, H.-C. Kim, S. Hur, J. Chung; Seoul/KR (
[email protected])
Purpose: To evaluate the usefulness of C-arm CT performed at the proper
hepatic artery or equivalent in patients with caudate lobe hepatocellular
carcinoma (HCC) for detection of the tumour-feeding artery during
chemoembolisation
Methods
and Materials: From July 2009 to June 2012, 1069 patients with
HCC underwent C-arm CT, and caudate lobe HCCs were found in 69 patients.
Among 69 patients, 17 patients was excluded because of size less than 1 cm
(n=6), hypovascular HCC (n=7), and presence of portal vein thrombosis (n=4).
Finally 52 patients were included. Two radiologists reviewed the C-arm CT
findings and treatment response on the first enhanced follow-up CT. And then
cumulative local recurrence rate was calculated
Results
Among 52 cases, we could find tumour-feeding arteries and their
origin in 48 individuals (92.3%). Sele ctive chemoembolisation via tumour-
feeding arteries was succeeded in 42 patients (87.5%). The cumulative local
recurrence rates at 6 months, 1 year, and 3 years were 19.4%, 32.8%, and
35.8%, respectively. The cumulative local recurrence rates was significantly
lower in the patients who have single tumour-feeding artery and treated with
selective chemoembolisation. In the multivariate Cox model for cumulative
local recurrence rates, selective chemoembolisation of the tumour-feeding
arteries was a significant important factor in lower local recurrence rates
(hazard ratio, 0.255; 95% CI: 0.089.0.731; P=0.011)
Conclusion
C-arm CT obtained at the proper hepatic artery or equivalent
level can demonstrate most of the tumour-feeding arteries supplying HCCs in
the caudate lobe
B-0384 11:15
Improved stability of lipiodol-drug emulsion for TACE of HCC results in
improved pharmacokinetic profile: proof of concept using idarubicin
M. Boulin
1, A. Schmitt1, J.-P. Cercueil1, M. Wendremaire1, D.-C. Imbs1,
E. Delhom2, M.-A. Pierredon-Foulongne2, B. Guiu2; 1Dijon/FR, 2Montpellier/FR
(
[email protected])
Purpose: We recently demonstrated that idarubicin was the most cytotoxic
drug amongst eleven anticancer drugs on three hepatocellular carcinoma
(HCC) cell lines. We aimed to select the most stable idarubicin-lipiodol
emulsion and test the hypothesis that a better emulsion stability results in a
lower systemic exposure of the drug after transarterial chemoembolisation
(TACE) for HCC.
Methods
and Materials: Nine emulsions with doxoru bicin 50-mg or idarubicin
10-mg and lipiodol 10-mL were prepared using the pumping method. Emulsion
stability was evaluated by measuring the separation between phases
(aqueous, emulsion and oil) at 37 °C. The approval of the institutional review
board was obtained to evaluate the pharmacokinetics of the most stable
emulsion (amongst the 9 tested) after intra-arterial injection and bland
embolisation (250 m calibrated microspheres) in eight unresectable HCC
patients. Blood samples were obtained in all patients at 0, 5, 15, 30, 120 min
and 24 hours after TACE to determine Cmax and area under the curve (AUC).
Results
The emulsion idarubicin 2 mg/mL + lipiodol (1:2 v:v) was the most
stable emulsion (no phase separation at 48 hours). After injection of the
emulsion, mean Cmax was 12.5 ng/mL. An estimation of the bioavailability
shows that about 40% of administered idarubicin was not found in the blood
and thus, remained in the liver. Compared to doxorubicin-lipiodol emulsion,
relative Cmax and AUC were 10 times lower using idarubicin.
Conclusion
Idarubicin-lipiodol emulsion is very stable over time and was
associated with a much better pharmacokinetic profile than doxorubicin-lipiodol
for TACE of HCC.
S218
BA C D E F G
Friday
B-0385 11:24
Quantitative evaluation of CT perfusion map as indicator of tumor
response to transarterial chemoembolisation and radiofrequency ablation
D. Fior, D. Ippolito, P.A. Bonaffini, M. Colombo, C. R.G.L. Talei Franzesi,
S. Sironi; Monza/IT (
[email protected])
Purpose: To assess if different interventional treatments (RFA and TACE) may
influence the evaluation of perfusion parameters obtained with CT-p.
Methods
and Materials: Thirty-three consecutive cirrhotic patients candidates
to TACE orRFA were included. CT-p study was performed on 16
multidetectorCT (Brilliance 16,Philips,NL)¸dose exposure was 120 Kv,
120 mAs.In all cases bolus injection of 50 ml of non ionic contrast
agent (350 mgI/ml) at a flow rate of 6 ml/sec was performed and forty dynamic
scans were acquired at a fixed table positi on.A dedicated perfusion software
which generated a quantitative map of arterial and portal perfusion by means
of colour scale was employed.The following perfusion parameters were
assessed before and after TACE:Hepatic perfusion (HP),Arterial
perfusion (AP),Blood Volume (BV),Hepatic perfusion Index (HPI),Time To
Peak (TTP).
Results
A complete treatment was obtained in 16 cases and incomplete
treatment in the remaining cases.The following perfusion data were obtained in
partially treated lesions:HP 43.2 ±15.1 ml/sec/100 gr;AP 38.7 ±8.8 ml/min; BV
20.7±9.5 ml/100 mg;TTP 24± 3.7 sec; HPI 61.7 ±7.5%.Corresponding value
calculated in patients without residual tumor were: HP 10.2 ±6.3; AP 10.4±7;BV
4.05±4.8; TTP 38.9± 4.2;HPI 9.9 ±9.2.While in normal liver the found
parameters were:HP 13.2 ±4;AP 12.3±3.4;BV 11.8±2.8; TTP 43.9± 2.9 and HPI
17.1±9.8.A significant difference (p < 0.001) was found for all parameters
between residual viable tumor tissue (p < 0.001)compared to successfully
treated lesion,due to the presence of resi dual arterial vascular structures in
viable portion of treated HCC.
Conclusion
According to our results, CT-p evaluation is not influenced by
TACE or RFA treatments, thus representing a feasible technique that allows a
reproducible quantitative evaluation of treatment response in HCC patients
B-0386 11:33
HCC treated by TACE with iodised oil: is one-month follow-up with MDCT
predictive of treatment efficacy? A correlation with longer follow-up
G.A. Zamboni, M. Ambrosetti, F. Lombardo, A. Contro, G. Mansueto, R. Pozzi-
Mucelli; Verona/IT (
[email protected])
Purpose: To compare the results of one-month follow-up MDCT after TACE
with iodised oil in patients with HCC with those of further follow-up, to confirm
the clinical value of routine one-month follow-up.
Methods
and Materials: We reviewed the 64-row MDCT scans performed 4
weeks after TACE with iodised oil (Lipiodol, Guerbet) on 29 patients with HCC
(26M, 3 F; mean age 67 years): unenhanced, arterial phase, portal-venous
phase and equilibrium phase images were available. Up to 2 nodules were
analysed per patient, and complete treatment of each nodule was diagnosed
based on the absence of residual enhancement. The results were compared
with those of subsequent contrast-enhanced imaging (MDCT, MRI or CEUS),
with a lesion-by-lesion analysis. Sensitivity, specificity, PPV and NPV for the
one-month follow-up were calculated by means of Fisher's test, using the later
follow-up as a gold-standard.
Results
A total of 40 nodules were analysed (mean diameter 27 mm). Further
follow-up was at an average of 6 months (2-26 months). When the nodule was
diagnosed as completely treated at one-month follow-up MDCT, this had 100%
sensitivity, 80 % specificity, 94% PPV and 100% NPV compared with
subsequent follow-up contrast-enhanced imaging.
Conclusion
Contrast-enhanced multiphasic CT is commonly used for the
follow-up of HCC after TACE. The results at one-month follow-up are
confirmed by later follow-up imaging.
B-0387 11:42
Combination of Sorafenib and transarterial chemoembolisation (TACE) vs
TACE vs Sorafenib protocol alone in advanced stage hepatocellular
carcinoma (HCC): retrospective study at three German liver centers
T.J. Vogl
1, J. Trojan1, M. Göller1, M. op den Winkel2, E. Schott3, M.-W. Welker1,
S. Zangos1, W. Bechstein1, S. Zeuzem1; 1Frankfurt a. Main/DE, 2Munich/DE,
3Berlin/DE (
[email protected])
Purpose: To compare combined Sorafenib and transarterial
chemoembolisation (TACE), TACE alone and Sorafenib alone for treatment of
patients with advanced hepatocellular carcinoma (HCC) according to
Barcelona Clinic Liver Cancer (BCLC) stage C.
Methods
and Materials: In this retrospective multicenter cohort study 185
patients with BCLC stage C treated with Sorafenib and TACE (group A, n=50),
TACE alone (group B, n=59) or Sorafenib alone (group C, n=76) were
retrospectively analysed for comparison from January 2007 to October 2012.
Portal vein infiltration, extrahepatic metastases, time-to-progression and overall
survival were evaluated. For patients of group A adverse events were also
documented.
Results
Portal vein infiltration was documented in 32% of patients in group A,
36% in group B, and 37% in group C. Extrahepatic metastases were present in
60% (group A), 34% (group B), and 49% (group C). Median time-to-
progression was 6.3 months in group A, 5.4 months in group B and 3.5 months
in group C. Median overall survival was 17.0 months in group A, 11.0 months
in group B and 9.0 months in group C. The most common adverse events in
the combined Sorafenib and TACE treatment were diarrhea (54%), hand-foot-
skin reactions (40%) and fatigue (36%). Due to adverse events, the Sorafinab
dose was reduced in 86% of patients in group A and stopped in 6%.
Conclusion
Combined Sorafenib and TACE treatment seems to be a
promising treatment option in patients with HCC in BCLC stage C, especially
when extrahepatic metastases are present. However, further prospective or
randomised studies are necessary.
B-0388 11:51
Comparison between transcatheter arterial chemoembolisation (TACE)
and transcatheter arterial chemoembolisation combined with
percutaneous radiofrequency ablation (TACE-RFA) for treatment of
intermediate hepatocellular carcinoma
E. Antonuccio, R. Iezzi, M. la Torre, A. Guerra, M. Nestola, L. Bonomo;
Rome/IT (
[email protected])
Purpose: To compare safety, tolerability, influence on liver function and
efficacy of TACE and single-step balloon-occluded RFA combined with TACE
(boRFA+TACE) in patients with unresectable multinodular HCC.
Methods
and Materials: 30 patients with HCC treated with boRFA+TACE
(Group A) were individually matched according to tumour type, age, sex and
liver disease stage with a group of 15 patients treated only with TACE (Group
B). The two groups were compared in terms of liver function, major
complications, time of hospitalisation, treatment efficacy (1, 6 and 12 months
CT, mRECIST criteria) and overall survival (OS).
Results
Hepatic liver function and Child-Pugh score did not significantly differ
amongst the two groups at 1 month. Technical success, defined as complete
or partial devascularisation during the arterial phase of all nodules obtained on
1-month CT, was achieved in 25/30 patients (83.3%) in A and 12/15 patients
(80%) in B, respectively. At 6-month CT, local recurrence was developed in
10/30 (33.3% A) and 5/15 (33.3% B). During one year follow-up, a mean
number of procedures per patient of 1.28 and 1.86 were obtained, respectively
(P <.05). No significant differences were found in terms of OS amongst the two
groups (median survival: 392±62 days, A; 487±38 days, B).
Conclusion
Both procedures were safe, well tolerable, not deteriorating liver
function, with good results in terms of efficacy and overall survival, without
significant differences. However, the use of combined therapy could be more
favourable than TACE alone in terms of cost-effectiveness in patients with
multinodular unresectable HCC, allowing to reduce the repeated number of
treatments.
10:30 - 12:00 Board Room A
Head and Neck
SS 508
Head and neck oncology
Moderators:
C. Czerny; Vienna/AT
R. Kohler; Sion/CH
B-0389 10:30
PET/MR and PET/CT in follow-up of head and neck cancer patients
M.A. Queiroz, P. Veit-Haibach, G. von Schulthess, M. Hüllner, F. Kuhn,
S. Kollias, G. Huber, C. Meerwein; Zurich/CH
(
[email protected])
Purpose: Positron Emission Tomography (PET)/Magnetic Ressonance
Imaging (MRI) is the emerging hybrid imaging modality. The aim of this study
was to assess contrast enhanced (ce) PET/MRI compared to
cePET/Computed Tomography (CT) in patients with suspected recurrence of
HNC.
Methods
and Materials: Eight-seven patients were enrolled in this prospective
study. All patients underwent PET/CT-MRI in a tri-modality setup. Diagnostic
accuracy concerning detection of recurrent HNC was evaluated for cePET/CT
and cePET/MRI, as well as image quality, presence of unclear FDG uptake
and diagnostic advantages of use of gadolinium.
Results
CePET/MRI showed no statistically significant difference in diagnostic
accuracy compared to cePET/CT (91.5% vs 90.6%). Artefacts grade was
similar in both methods, while their location was different. CePET/CT artefacts
were primarily located in the supra-hyoid area, while cePET/MRI, artefacts
S219
BA C D E F G
Friday
were more equally distributed among the supra and infra-hyoid neck regions.
Both methods showed 34 unclear FDG uptake, of those eleven could be
solved by cePET/MRI and five by cePET-CT. The use of gadolinium in
PET/MRI didn't yield higher diagnostic accuracy, but helped to define tumour
margins in 6.9% of patients.
Conclusion
CePET/MRI might be slightly superior compared to cePET/CT to
solve unclear FDG uptake related to possible tumour recurrence in patients
with follow-up after HNC. It might also be the imaging tool of choice for
evaluation of the oropharynx and the oral cavity based on a higher incidence of
technical artefacts in cePET/CT in this area. However, overall there is no
statistically significant difference concerning diagnostic accuracy of the two
methods.
Author Disclosures:
P. Veit-Haibach: Grant Recipient; Bayer Healthcare and Siemens Medical
Solution. Speaker; GE Healthcare. G. von Schulthess: Speaker; GE
Healthcare.
B-0390 10:39
Use of DWI in PET/MRI for head and neck cancer evaluation
M.A. Queiroz, P. Veit-Haibach, G. von Schulthess, M. Hüllner, F. Kuhn,
S. Kollias, G. Huber, C. Meerwein; Zurich/CH
(
[email protected])
Purpose: The novel method 18 F-fluorodeoxy-D-glucose (FDG) positron
emission tomography / magnetic resonance imaging (PET/MRI) is an attractive
alternative to PET/Computed Tomography (CT) on imaging evaluation of head
and neck cancers (HNCs). Defining MR protocol is a challenge, since there are
many different sequences and acquisition time should not be too long. The aim
of this study is analyse whether DWI adds significant information to PET/MRI
on lesion detection for HNCs.
Methods
and Materials: Seventy patients were enrolled in this prospective
study. All patients underwent sequential contrast enhanced (ce)PET/CT and
cePET/MRI using a tri-modality PET/CT-MR setup. First, all the lesions were
assessed by PET/MRI with conventional sequences and, in a second step, the
PET/MRI with DWI sequence. The PET values (Standardised Uptake Value-
SUV) and DWI values (Apparent Coefficient Diffusion-DC and B value) of all
FDG positive lesions were also evaluated.
Results
One hundred and eighty-eight lesions were found, in which 118 were
malignant and 70 were benign. DWI detected 120 lesions, while PET/MRI
identified 48 more lesions. DWI showed 20 lesions not seen on PET/MRI.
However, those additional lesions did not change the overall staging. SUV
maximum and mean were higher in malignant lesions than in benign lesions,
but DWI values were not statistically different.
Conclusion
PET/MRI is superior to DWI alone and thus, DWI is not needed in
PET-MRI protocols for HNC detection.
Author Disclosures:
P. Veit-Haibach: Research/Grant Support; Bayer Healthcare and Siemens
Medical Solution. Speaker; GE Healthcare. G. von Schulthess: Speaker; GE
Healthcare.
B-0391 10:48
Diffusion-weighted MRI in advanced oropharyngeal carcinoma treated by
exclusive chemoradiation therapy: prognostic value of histogram-derived
parameters
M. Plebani, M. Ravanelli, L. Costa, V. Kengni Fondjie Legrand, D. Farina,
R. Maroldi; Brescia/IT (
[email protected])
Purpose: To assess the prognostic value of histogram parameters extracted
from diffusion-weighted (DW) pre-treatment MRI in patients treated by
exclusive chemoradiation therapy (CHRT) for advanced oropharyngeal
carcinoma.
Methods
and Materials: Pre-treatment DW-MRI datasets from patients who
underwent CHRT for advanced oropharyngeal carcinoma from October2007 to
November2011 were retrospectively reviewed and analysed. Histogram
analysis was performed on Apparent Diffusion Coefficient (ADC) maps for
primary tumour (T), peritumour ring and largest nodal metastasis (N), resulting
in the following parameters: ADC mean, max and min, histogram skewness
and kurtosis. Kaplan-Meier analysis was performed to test prognostic value
(overall survival, OS; progression-free survival, PFS).
Results
DWI datasets from 27 patients were reviewed by an expert radiologist
blinded to clinical outcome. Analysis at T, peritumour and N site was feasible in
23, 23 and 16 patients. Maximum ADC and skewness of T were significantly
higher in good responders (n=14) than in poor responders (n=9) (p 0.004 and
0.005, respectively). Multiplying ADC max and skewness, a novel parameter
(skew*max) was obtained. At Kaplan -Meier analysis, ADC max, skewness and
skew*max, categorised by median split, did correlate with OS, with hazard
ratios of respectively 3.47 (p0.02), 6.57 (p0.005) and 15.45 (p0.0004). Similar
Results
were obtained for PFS, being disease progression and mortality strictly
associated. Nine out of 11 patients with low skew*max values did relapse
during follow-up; only one recurrence was observed in 12 high skew*max
patients (p0.002).
Conclusion
Skew*max derived from ADC histograms is a promising
prognostic indicator for advanced oropharyngeal carcinoma treated by
exclusive CHRT.
B-0392 10:57
Characterisation of head and neck tumors using dynamic contrast
enhanced MRI
G. Léránt, P. Sárközy, L. Jávor, C. Szalay, A. Lévai, M. G dény; Budapest/HU
(
[email protected])
Purpose: To assess the diagnostic value of dynamic contract enhanced MRI
(DCE-MRI) in differentiation between malignant and benign head and neck
(HN) lesions, and between changes caused by radiation therapy.
Methods
and Materials: 150 patients with HN tumor were examined using
DCE-MRI sequences (Fast Spoiled Gradient Echo FSPGR, 80 phases), beside
routine head neck (HN) imaging protocol. The examinations were performed
on a 3 Tesla wide bore clinical MR scanner (General Electric Discovery 750w,
Milwaukee, USA). As contrast agent gadobenate dimeglumine (Multihance©,
Bracco, Italy) were applied. The time intensity curves (TIC) were extracted from
the region of interests (ROI) specified by experienced HN radiologists. The
TICs were used to acquire time-to-peak (TTP), relative maximum
enchancement (RME), relative wash-out (RWO) and other parameters. The
parameters were analysed using univariate tests and multivariate models in
SPSS 17 to identify predictors that can be used to infer tumor malignancy and
post-irradiation status.
Results
Multiple parameters of curve characteristics are significantly different
in case of malignant vs. post-irradiation status, and also in case of malignant
vs. benign tumors. We investigated the per formance of logistic regression to
identify the status of a tumor, and found multiple significant (p < 0.05)
predictors for both benign/malignant status as well as pre- and post-irradiation
status.
Conclusion
This large cohort of data supports the increasing role of DCE-MRI
in HNT differentiation.
B-0393 11:06
Dynamic contrast enhanced MRI for differentiation of major salivary
glands neoplasms, a 3-T MRI study
L. Aghaghazvini, H. Sharifian, F. Salahshur, N. Yazdani, M. Shakiba,
S. Kooraki; Tehran/IR (
[email protected])
Purpose: Evaluate the role of dynamic contrast-enhanced MRI (DCE) for
differentiation between malignant, Warthin and benign non-warthin (BNW)
neoplasms of major salivary glands.
Methods
and Materials: 46 salivary gland neoplasms underwent preoperative
DCE. Postoperative histopathologic evalua tion was performed for a definite
diagnosis. (30 BNW, 6 Warthin, 10 malignant) TIC (Time-signal intensity
curves) were categorised as (A) Tpeak > 43s and WR180 43s and WR180:4.6-22% (C) Tpeak 22%.
Results
Accuracy of Tpeak was 98.9% for differentiation between BNW and
Warthin, 83.7% between BNW and malignant and 80% between malignant and
Warthin. All warthins showed Tpeak 43s, while one BNW had Tpeak < 43s. A
Tpeak< 63.5s differentiated 8/10 (80%) of malignant tumors from BNW, while
4/30 of BNW had a Tpeak < 63.5s. Two malignant tumors had Tpeak < 43s.
WR180 had an accuracy of 100% for differentiation between warthin and BNW,
87.3% between BNW and malignant and 93.3% between warthin and
malignant tumors. 29 out of 30 (96.7%) BNW had a washout 4.60%. All warthins had a
WR180> 22%, while two malignant tumors had a WR180 > 22%. According to
TIC curves, 29/30 of BNW demonstrated TIC curve type A and one
demonstrated type B. 6/10 of malignant tumors had TIC type B, 2 had TIC type
A and 2 type C. All warthin were categorised in Type C.
Conclusion
This study showed DCE could assist in preoperative
differentiation of salivary gland neoplasms; especially regarding discrimination
between warthin and BNW tumors.
S220
BA C D E F G
Friday
B-0394 11:15
Assesment of global and locoregional heterogeneity of primary
squamous cell carcinoma of the head and neck: association with
treatment response and clinical outcome
I. Sowemimo, M. Siddique, S. Connor, M. McGurk, C. Yip, T. Guerrero-Urbano,
S. Gourtsoyianni, G. Cook, V.J. Goh; London/UK (
[email protected])
Purpose: Our aim was to assess the relationship between CT and MRI
evaluation of whole tumour heterogeneity with response to treatment and
clinical outcome. We hypothesised that image heterogeneity may reflect
underlying tumour biology.
Methods
and Materials: Following IRB approval, the imaging heterogeneity of
contrast enhanced MDCT (ceCT), contrast enhanced T1-weighted 1.5 T-MRI
(ceMRI), and T2-weighted 1.5 T-MRI (T2MRI) of 33 patients (21 men, mean
62.7 years) with primary squamous cell carcinoma of the head and neck were
evaluated using global and locoregional methods: first-order statistics; second-
order co-occurrence matrices; higher-order run length (GLRL) and
neighbourhood grey-tone difference (NGTDM); and model-based fractal
analysis (FA). Parameters were compared with Stage, treatment outcome and
survival using Mann Whitney and Kaplan Meier statistics.
Results
There was a difference in ceCT and T2MRI parameters between
early and advanced cancers (p < 0.01). Higher-order locoregional GLRL and
NGTDM may better reflect clinical outcome in primary head and neck cancer
with a difference between treatment responders/non-responders as well as
patients with recurrence/no recurrence (p < 0.05). There was a borderline
association between ceCT kurtosis and overall survival (log rank p=0.046) in
comparison to tumor size where there was no difference, using an optimal 'cut-
off' threshold.
Conclusion
While findings are preliminary, assessment of global and
locoregional imaging heterogeneity may augment current imaging practice with
respect to clinical outcome.
B-0395 11:24
The role of magnetic resonance spectroscopy for differentiation between
major salivary glands neoplasms
L. Aghaghazvini, H. Sharifian, S. Omidi, N. Yazdani, S. Kooraki; Tehran/IR
(
[email protected])
Purpose: To assess the role of magnetic resonance spectroscopy (MRS) for
preoperative differentiation between benign non-Warthin (BNW),Warthin and
malignant neoplasms of major salivary glands.
Methods
and Materials: 43 major salivary gland neoplasms (25 BNW, 7
Warthin and 11 malignant) underwent preoperative MRS. Final diagnosis was
confirmed with postoperative histopathologic evaluation. MRS was performed
with echo times (TE) of 135 and 270 at 3 Tesla. Spectra was analysed to
determine peak amplitude of choline (Cho), creatine (Cr) and cho/cr ratio. ROC
curve was used to determine optimal cutoff points.
Results
Mean cho/cr at TE135 was 1.84 ±2.05, 1.16 ±0.64 and 3.90± 3.23 in
BNW, Warthin and malignant neoplasms, respectively. Mean cho/cr at TE270
was 1.66 ±1.85, 0.97 ±0.47 and 3.18± 1.53 in BNW, Warthin and malignant
neoplasms, respectively. Cho/cr had an accuracy of 78.9% at TE135 (best
cutoff point 1.92 with 81.8% sensitivity and 88% specificity) and 81.5% at
TE270 (best cutoff point 1.92 with sensitivity of 81.8% and specificity of 84%)
for differentiation between BNW and malignant tumours. MRS was powerful for
differentiation between Warthin and malignant neoplasms showing a cho/cr
accuracy of 87% and 92.2% at TE135 and TE270, respectively. Cutoff points
of 1.59 at TE135 (sensitivity 81.8%, specificity 85.7%) and 1.25 at TE270
(sensitivity 90.9%, specifici ty 85.7%) were powerful in differentiation between
malignant and Warthin neoplasms. MRS wa s not powerful for differentiation
between BNW and Warthin tumours.
Conclusion
This study showed that MRS is helpful in preoperative
discrimination of major salivary gland neoplasms.
B-0396 11:33
To evaluate the efficacy of MRI in detection of cartilage invasion and
submucosal space involvement in laryngeal cancer for accurate
pretherapeutic staging
S. Priya, S. Mehra; New Delhi/IN (
[email protected])
Purpose: To evaluate the efficacy of MRI in detection of cartilage invasion for
accurate pretherapeutic staging.
Methods
and Materials: 33 patients with endoscopically diagnosed laryngeal
masses were included in a prospective study. CECT and CEMR were
performed to assess cartilage invasion. The median age group was 51-60
years with 29 males and 4 females. 19 patients underwent total laryngectomy
with histopathology of the resected specimen. CT was performed on Philips
Brilliance 40-slice spiral scanner. CEMRI was performed on Siemens 1.5 T
scanner using surface neck coils (slice thickness of 3-4 mm and 1 mm
intersection gap).
Results
CT: 14 masses were characterised as T4, 10 as T3, 5 as T2 and 4 as
T1. Diagnostic accuracy of CECT was 73% for staging and for cartilage
invasion was 78% for thyroid and cricoid and 79% for arytenoid. MR: 15
masses were characterised as T4, 5 as T3, 6 as T2 and 3 as T1 with
diagnostic accuracy of 89% for staging. MR had higher accuracy in detecting
cartilage invasion with 89% accuracy for thyroid, 78% for cricoid and 84% for
arytenoid cartilage. Histopathology: There were 2 false positive MR results for
thyroid and arytenoid each and 4 for cricoid cartilage invasion. CECT had
lower diagnostic accuracy for staging and for cartilage invasion with 3 false
negative results for thyroid cartilage and 2 for arytenoid and cricoid cartilage.
Conclusion
CEMR has higher sensitivity and accuracy in detecting cartilage
invasion. MR should be used as first line imaging modality for laryngeal tumour
evaluation.
B-0397 11:42
The value of ultrasonographic criteria for the differential diagnosis
between benign and malignant cervical lymph nodes
L.M. Lenghel, G. Bciu#, A. Bojan, C. Botar-Jid, D. Vasilescu, D. Feier,
S.M. Dudea; Cluj-Napoca/RO (
[email protected])
Purpose: The aim of the study is to explore th e diagnostic value of grey scale,
Doppler and sonoelastographic criterias for the differentiation between benign
and malignant lymph nodes of the neck.
Methods
and Materials: Over a period of 42 months (October 2009 - April
2013) the patients examined routinely for the assessment of superficial cervical
lymph nodes in the department of ultrasound were recorded in a database
containing grey-scale, Doppler and sonoelastographic information and images.
The images of 30 benign and 60 malignant (20 lymphomas and 40 metastatic)
lymph nodes obtained were chosen. The images obtained at real-time
elastography were scored according to a new scoring system using 6 patterns,
comparing the sonoelastographic appearence with bidimensional images.
Results
In the multivariate analysis, none of the bidimensional criaterias
proved to be independent predictors of malignancy. From the Doppler
parameters, the vascular pattern was an indepedent predictor of malignant
lymph nodes. It was analysed the diagnostic value of the vascular pattern with
area under the ROC curves (AUROC) = 0.89,p < 0.0001, sensibility = 90%,
specificity= 83.3% and sonoelastographic scores area under the ROC curves
(AUROC) = 0.86,p < 0.0001, sensibility = 78.3%, specificity= 90%.
Conclusion
In this study, the vascular pattern assessed on Doppler images
and the sonoelastographic scores are the most important predictors of
malignancy, with a very good sensibility and specificity.
B-0398 11:51
Ultrasound-guided transcutaneous tru-cut biopsy of laryngo
hypopharyngeal lesions
G. Conte, E. De Fiori, E. Perucchini, L. Preda, L. De Benedetto, M. Ansarin,
M. Bellomi; Milan/IT (
[email protected])
Purpose: To evaluate the performance of ultrasound-guided transcutaneous
tru-cut biopsy (USGTCB) in patients with untreated or previously treated
suspicious laryngo-hypopharyngeal masses, who have relative or absolute
contraindications for microlaryngoscopy.
Methods
and Materials: From August 2004 to April 2013, we prospectively
enrolled 62 patients (47 males, 15 females; age 44-95 years), for total of 64
USGTCBs scheduled: 37 USGTCBs were performed for an untreated mass
suspicious of malignancy and 27 for suspicious recurrence of malignancy.
Biopsies were performed with the free-hand technique by a single radiologist
after the preliminary assessment by US of the mass.
Results
USGTCB diagnosed 47 squamous cell carcinomas, 6 other malignant
lesions and 11 benign lesions (true positi ve); no false positives and five false
negatives were reported: two in patients with untreated lesions, two in patients
previously treated with radiotherapy and one in a patient previously treated
with endoscopic laser surgery. Overall, the sensitivity of the technique was
91.4%; the specificity was 100%; positive and negative predictive values were
100% and 54.5%, respectively. Sensitivi ty, specificity, po sitive and negative
predictive value and accuracy for the procedures performed in previously
radio-treated patients were 84.6%, 100%, 100%, 71.4%, respectively.
Conclusion
Although biopsy under microlaryngoscopy remains the "gold-
standard" technique for histological diagnosis of both primary and recurrent
laryngo-hypopharyngeal masses, USGTCB is a cost-effective procedure that
could be applied in patients contraindicated for general anaesthesia or those
with a risk of tracheotomy due to intubation difficulties. The performance of
USGTCB is adequate even in previously radio-treated patients to differenatiate
recurrence of malignancy from radio-necrosis.
S221
BA C D E F G
Friday
14:00 - 15:30 Room A
GI Tract
SS 601a
New insights into colorectal cancer
Moderators:
C. Hoeffel; Reims/FR
P. Wylie; London/UK
B-0399 14:00
Diagnostic accuracy of MR vs rigid rectoscopy in assessing the
extraperitoneal location of rectal cancers
M. Revelli, C. Puppo, F. Paparo, R. Piccazzo, D. Astengo, L. Bacigalupo,
A. Pascariello, G.A. Binda, G.A. Rollandi; Genua/IT
(
[email protected])
Purpose: Our purpose was to compare the diagnostic accuracy of rigid
rectoscopy and MR in assessing the extra or intraperitoneal location of rectal
cancers, using surgical exploration as reference standard.
Methods
and Materials: Patients with surgically proven primary rectal
adenocarcinoma were retrospectively identified and all patients who underwent
preoperative rectoscopy and MR were enrolled. Patients with a complete
response to chemoradiation therapy were excluded. All MR examinations were
reviewed by two abdominal radiologists in consensus, determining the intra or
extraperitoneal location of tumour's inferior edge. Three different cut-off
measurements were used to define the diagnostic accuracy of rectoscopy:
< 8 cm, < 10 cm and < 12 cm.
Results
54 patients (32 male, 22 female, mean age 69.2 years) with surgically
proven primary rectal adenocarcinoma (47 extra and 7 intraperitoneal tumours)
were included. MR showed a sensitivity and specificity of 95.74% and 100%,
respectively. Rigid rectoscopy showed a sensitivity and specificity of 93.75%
and 66.67% at 8 cm, 97.87% and 57.14% at 10 cm and 100% and 14.29% at
12 cm (p = 0.007).
Conclusion
MR, due to the direct visualisation of the anterior peritoneal
reflection, showed higher specificity than rectoscopy in defining the
extraperitoneal location of rectal cancers.
B-0400 14:09
Tumour volumetry on diffusion-weighted MRI for identification of
complete tumour responders to preoperative chemoradiotherapy in rectal
cancer: a multicenter validation study
D.M. Lambregts
1, S. Sassen2, S.-X. Rao1, M.H. Martens1, L.A. Heijnen1,
G.L. Beets1, R.A. Vliegen2, R.G.H. Beets-Tan1; 1Maastricht/NL, 2Heerlen/NL
(
[email protected])
Purpose: Retrospective studies have shown that tumour volumetry using
diffusion-weighted imaging (DWI) may help i dentify rectal cancer patients with
a complete tumour response after neoadjuvant chemoradiotherapy (CRT). This
study aims to prospectively validat e the diagnostic value of previous
retrospectively determined volume-thresholds in a larger and multicentric
patient cohort.
Methods
and Materials: 119 patients from two different centres underwent
MRI (1.5 T) including standard T2W-MRI and DWI (highest b-value b1000-
1100), both pre- and post-CRT. An experienced reader placed free hand ROIs
around the tumour area on each tumour-containing slice to determine pre-CRT
and post-CRT volumes (cm3) on T2W-MRI and DWI and calculate volume
(=[pre-volume - post-volume]/[pre-volume]*100%). T2W and DWI thresholds
(retrospectively determined in previous studies) for pre-volume, post-volume
and volume were tested to prospectively assess their diagnostic values in
identifying patients with a complete tumour response.
Results
Twenty-one patients had a complete response. Areas under the
ROC-curve for the pre-/post-/ ,-volumes were 0.73/0.80/0.69 for T2W-MRI and
0.75/0.86/0.78 for DWI. For T2W-volumetry, sensitivity and specificity using the
predefined thresholds were 62% and 74% for pre-volume, 52% and 92% for
post-volume and 38% and 86% for volume. For DWI-volumetry, sensitivity
and specificity were 62% and 77% for pre-volume, 62% and 91% for post-
volume and 71% and 80% for volume.
Conclusion
Previously determined DWI volume-thresholds can be
reproduced with good results in a prospective and multicenter setting. Post-
CRT DWI-volumetry provides the best results for discriminating complete
responders with an AUC of 0.86 and - prospectively tested - sensitivity of 62%
and specificity of 91%
B-0401 14:18
Diffusion-weighted images in differentiation of granulation tissue from
minimal portion of residual tumour in the cases of the assumption of
complete response after chemoradiotherapy of patients with rectal
cancer
K.B. Puzakov, N.A. Rubtsova, I.V. Droshneva, D.V. Sidorov,
O.A. Mainovskaya; Moscow/RU (
[email protected])
Purpose: The aim of the study was to determine the differentiation of epithelial
granulation from residual tumour in cases of the assumption of complete
response after chemoradiotherapy.
Methods
and Materials: The study included 86 patients with rectal cancer.
Studies were performed on 1.5 T MR imaging with a flexible 4-channel body
coil. Analysis was used in the ADC by one section outlined with hand-rendered
all parts of the tumor. Maps ADC automatically generated upon completion of
DWI sequences. Evaluation ADC of rectal tumors was carried out on the stage
prior to the n-CRT and 4-6 weeks after. In all cases, MRI and histology data
are compared. Scanning protocol includes multiplanar T2 and T1WI with
intrarectal contrasting agent and in DWI with b-factor (0 and 800 mm²/sec).
Results
There were 12 complete responders according to pathomorphological
data with no tumour growth among fibrotic mass. According to MRI data (T2WI
+ DWI), there were considered only 8 complete responders, but 1 (1.2%) case
was false-negative because of microfocus (small groups of adenocarcinoma
cells) of the tumor which has no chance of MRI detection, there were 7 (8.1%)
true-negative cases of complete response. In 5 (5.8%) cases, granulation
tissue was wrongly defined as tumor fa lse-positive results. Sensitivity,
specificity, accuracy, PPV, NPV were 98.7%, 58.3%, 93%, 93.6% and 87.5%,
respectively.
Conclusion
After the retrospective analysis, we found no statistically
significant differences between the ADC of the small residual tumour and the
granulation epithelial tissue (1.329x10
-3 mm 2/s and 1.387x10 -3 mm 2/s,
respectively). This caused a lack of specifici ty with the method in this difficult
group of patients. Therefore, this issue needs further study.
B-0402 14:27
Preoperative 3 T MR imaging of rectal cancer: local staging accuracy
using 2D T2-weighted FSE sequence and diffusion-weighted MRI with b-
multiple SE-EPI
P. Boraschi, F. Donati, E. Marciano, R. Balestri, G. Gherarducci, F. Pacciardi,
E. Neri, F. Falaschi, C. Bartolozzi; Pisa/IT (
[email protected])
Purpose: To evaluate the image quality and diagnostic performance of 2D
T2w FSE sequence and Dw-MRI with b-multiple SE-EPI in the local staging of
rectal cancer at 3 T.
Methods
and Materials: Forty patients with biopsy-proven rectal cancer
underwent MRI at 3 T-device (GE-DISCOVERY MR750; GE Healthcare) using
8-channel phased-array body coil. MR imaging protocol included high-
resolution 2D T2w FSE images in sagittal, coronal, axial and axial-oblique
planes. Dw-MRI was performed using axial spin-echo echo-planar sequence
with multiple b -values (150,500.1000,1500 sec/mm²) in all diffusion directions.
Two experienced radiologists separately reviewed the 2D T2w imaging data-
set alone and the combined set of T2w and Dw-MR images. The reviewers
assessed the radiologic T staging with regard to tumor extension to the
muscularis propria and perirectal fat invasion and performed image quality
assessment of data-sets using a five-point scale.
Results
Thirty-two patients who underwent a total mesorectal excision (TME)
were enrolled in the imaging analysis; the remaining 8 patients were excluded
because they were classified as stage T1 (two cases) and stage T4 (six
cases). The overall sensitivity, specificity and accuracy for prediction of
perirectal fat invasion in rectal cancer using the combined set of T2w and Dw-
MR images and the T2w imaging data-set alone were 94%, 78%, 87.5% and
77%, 57%, 68.7%, respectively. Image quality analysis was performed in all 40
patients and was excellent on T2w images and good on Dw-MRI.
Conclusion
Diffusion-weighted MR imaging in addiction to T2-weighted MR
imaging can improve the local staging of rectal cancer at 3 T.
S222
BA C D E F G
Friday
B-0403 14:36
Diagnostic performance of kinetic parameters derived from dynamic
contrast-enhanced MRI for the selection of good responders after
chemoradiation for rectal cancer
M.H. Martens, S. Subhani, L.A. Heijnen, D.M. Lambregts, M. Maas, R.G. Riedl,
G.L. Beets, E. Kluza, R.G.H. Beets-Tan; Maastricht/NL
(
[email protected])
Purpose: Response assessment after chemoradiotherapy (CRT) in rectal
cancer remains difficult. The aim of this study was to investigate if kinetic
paramters derived from dynamic contrast-enhanced (DCE) MRI, using the
blood-pool contrast agent gadofosveset, can identify good responders after
CRT.
Methods
and Materials: Twenty-five patients with locally advanced rectal
cancer received DCE-MRI both before and 8 weeks after CRT. The kinetic
parameters i.e., the initial slope, initial peak, late slope, and area under the first
60, 90, and 120s of the enhancement curve (AUC 60, AUC 90, AUC 120) were
determined from relative signal enhan cement-time curves. Receiver operating
characteristics (ROC) curves were used to assess the diagnostic performance.
Good responders (n=11) were defined as patients with a tumour regression
grade (TRG) of 1 or 2 at histopathologic assessment after resection. Poor
responders were defined as patients with a TRG of 3 to 5 (n=14).
Results
Before neo-adjuvant CRT, the late slope was significantly lower for
the good responders (-1.61x10
-3) compared with the poor responders (5.18x10 -
3, p=0.004). Post-CRT the initial peak, AUC 90, and AUC 120 were significantly
lower in the good responders compared with the poor responders (1.20vs1.53,
102vs128, 145vs181 and p=0.017, 0.028, 0.023 respectively). All parameters
except the late slope changed significantly more post-CRT in the good
responders compared with the poor responders. ROC-curves ranged from 0.73
to 0.83.
Conclusion
Kinetic parameters derived from dynamic contrast-enhanced MRI
are a promising tool for prediction and assessment of response after
chemoradiotherapy in patients with rectal cancer.
B-0404 14:45
Differentiation of poorly differentiated colorectal adenocarcinomas from
well- or moderately differentiated colorectal adenocarcinomas at
contrast-enhanced multidetector computed tomography
J.E. Kim
1, J.M. Lee2, J.H. Baek2, S.K. Moon2, J.K. Han2, B.I. Choi2; 1Jinju/KR,
2Seoul/KR (
[email protected])
Purpose: To describe the CT findings of poorly-differentiated (PD) colorectal
adenocarcinoma (CRAC) and to identify the features that differentiate it from
well- (WD) or moderately-differentiated (MD) CRAC.
Methods
and Materials: One-hundred and thirteen patients with pathologically
proved PD (n = 26), WD (n = 35), or MD (n = 52) CRACs who had undergone
preoperative contrast-enhanced multidetector CT (MDCT) imaging were
included in this study. Analysis of CT fi ndings included determination of the (a)
location and shape of the tumour; (b) enhancement pattern and degree, and
maximal wall thickness of the tumour; (c) pericolic fat infiltration; (d) size and
enhancement degree of the regional lymph nodes (LNs); and (e) presence of
direct invasion, colonic obstruction, and distant metastasis. The significance of
these findings was determined with the x
2 test.
Results
ignificant features in the differentiation of PD CRACs from WD or MD
CRACs included bulky shape, heterogeneous enhancement, the same or lower
attenuation compared with muscle within the tumour, nodular pericolic fat
infiltration, regional LNs being more than 10 mm in short axis diameter,
regional LNs with the same or lower attenuation compared with muscle, and
presence of distant metastasis (P < 0.05). When at least two of these seven
imaging features were used in combination, sensitivity and specificity in the
diagnosis of PD CRACs were 88% and 70%, respectively.
Conclusion
By using characteristic CT features, one can differentiate PD
CRAC from WD or MD CRAC with a high degree of accuracy at contrast-
enhanced MDCT.
B-0405 14:54
Comparison between CT with multiplanar reconstructions and MRI for
prediction of neoadjuvant therapy in rectal cancer
M. Jaffro, S. Lagarde, S. Collot, P. Otal, H. Rousseau, F.-Z. Mokrane;
Toulouse/FR (
[email protected])
Purpose: The objective of this study was to compare the multidetector-row CT
(MDCT) with multiplanar reconstructions and MRI in the decision of
neoadjuvant therapy in rectal cancer.
Methods
and Materials: During a 4-year period, all patients who were enrolled
in this study had biopsy-proven rectal carcinoma, CT of the abdomen and
pelvis and MRI of the pelvis. Two radi ologists, an expert and a junior reviewed
all examinations independently. They were blinded one from the other, from
the findings of the other modality, and from clinical information. Only T3
tumours, staged using MRI by the expert were analysed. Agreement between
MRI and MDCT, inter-observer agreement concerning neoadjuvant therapy
decision and all tumor characteristics were calculated.
Results
Among the 62 studied patients, the neoadjuvant radiochemothrapy
was indicated in 56 patients (90.3%). In the prediction of neoadjuvant
radiochemotherapy by CT, the agreement between the two modalities was
0.73, the sensitivity was about 98%, t he specificity was about 75%, the PPV
was about 98% and the NPV was about 75%. Inter-observer agreement was
0.73 for the MRI and 1.00 for the CT. Agreement between MDCT and MRI
was: for mesorectal fascia characteristics 0.73, for nodes status 0.53, for
vascular invasion 0.19, for tumour deposit 0.48, for tumour spread into
mesorectum 0.14, and for size 0.49. Inter-observer agreement were ranged
from 0.40 to 1.00 for the CT and from 0.56 to 1.00.
Conclusion
Our findings suggest that MDCT with multiplanar reconstructions
can replace MRI for the prediction of neoadjuvant therapy.
B-0406 15:03
Does tumour size matter? Correlation of rectal tumour volumes with
oncological outcomes in low rectal cancers
M. Tayyab1, M. Subhani2, R. Karim2, E.T. Razia3, A. Razack1; 1Cottingham/UK,
2Carmarthen/UK, 3Barrow/UK (
[email protected])
Purpose: The relationship between tumour volume and oncological outcome
has been reported in cases of brain, nasopharyngeal, lung, hepatocellular and
prostate cancers. There is paucity of similar data in rectal cancer. The aims of
this study were to determine whether tumour volume and mesorectal volume
evaluated by magnetic resonance imaging (MRI) have effects on oncological
outcomes of rectal cancer.
Methods
and Materials: Volumetric analysis of rectal tumours was performed
from the MRI images and then correlated with oncological outcomes. The
study was based on a clinical and radiological database of patients who
underwent rectal cancer surgery in a tertiary teaching centre during the year
2004.
Results
35 patients underwent rectal cancer surgery after staging with MRI
during the study period. Of these, seven could not have their MRI images
retrieved and were, therefore, excluded from further analysis. 3 further patients
had metastases identified at diagnosis and were also excluded. Tumour
volume (TV) was a significant predictor of overall survival HR (95%CI); 5.8
(1.2-29), (P=0.03). Mesorectal volume (MRV) and TV/MRV did not show any
correlation with oncological outcomes. LNR, TME and inadvertent perforation
were other independent predictors of oncological outcomes following APER.
Conclusion
Tumour volume showed a direct relationship with overall survival
and this may be used to stratify rectal tumours for neoadjuvant therapy;
however, a larger prospective study is required to prove this correlation.
B-0407 15:12
Preliminary study of low-tube voltage scan in evaluation of T-staging of
rectal cancer with dual-source CT
G. Shi, Y.-N. Wang; Shijiazhuang/CN (
[email protected])
Purpose: The purpose of this study was to investigate the effect of low tube
voltage in evaluation of T-Staging of rectal cancer with dual-source CT.
Methods
and Materials: Forty patients (25 men ,15 women) underwent
contrast-enhanced abdominal DSCT. Data were reconstructed as three
groups: group A, fused image reconstructed with D30 (filter back projection
FBP) ;group B, 80 kV image reconstructed with D30 and group C ,80 kV image
reconstructed with I30 (iterative reconstruction IR). The mean CT numbers,
noise and SNR of organs and lesions were assessed quantitatively in each
group. Diagnostic accuracy was statistically compared related with pathologic
staging between three groups.
Results
Noise of group A and C had no difference (P > 0.05), while lower than
group B (P 0.05), while higher than group B (P 0.05), while lower
than group C (P 0.05), while SNR of rectal cancer at group A and C higher
than group B (P 0.05), while higher than group B (P < 0.05).
Conclusion
Obtained with 80 kV (with iterative reconstruction) is feasible and
the images are satisfactory for T-Staging of rectal cancer.
B-0408 15:21
MR tumour volumetry for tumour response evaluation after neo-adjuvant
chemoradiation- in rectal cancer: a prospective validation study
M.H. Martens, R.C. Dresen, D.M. Lambregts, L.A. Heijnen, T.J. Hua, W. Mok,
G.L. Beets, R.G.H. Beets-Tan; Maastricht/NL (
[email protected])
Purpose: The assessment of tumour response after chemoradiation (CRT) in
rectal cancer remains difficult. Morphologic evaluation on T2-weighted MRI is
not accurate to predict tumour downstaging. Studies have suggested that
assessment of tumour volume may improve the accuracy, but this has only
S223
BA C D E F G
Friday
been tested retrospectively. Aim of this study was to prospectively determine
the value of tumour volumetry by testing previously reported volume thresholds
in a new cohort of locally advanced rectal cancers treated with CRT.
Methods
and Materials: Seventy-three patients with a cT3-4 locally advanced
rectal tumour were included. Tumour volume (estimated as height x length x
width) was analysed before and after CRT. The reduction in tumour volume
(%) was calculated. The primary tumour volume and volume reduction after
CRT was compared between responders (ypT0-2) and non-responders (ypT3-
4) using Mann Whitney U test. Sensitivity, specificity, positive predictive value
(PPV), and negative predictive value (NPV) were calculated using a predefined
cut-off of > 75% reduction in tumour volume (according to previous reports).
Results
The volume of the primary tumour was significantly smaller in de
ypT0-2 group compared to ypT3-4 tumours (97.0 vs 172.8 cm 3, p=0.008).
Volume reduction rates were significantly higher in ypT0-2 than in ypT3-4
tumours (86.7 vs 72.4%, p 75% reduction
resulted in a sensitivity of 88%, specificity 59%, PPV 65%, and NPV 85% for
detecting ypT0-2.
Conclusion
This study has prospectively confirmed that a reduction in tumour
volume of > 75% MRI can predict tumour downstaging to yT0-2 with a high
sensitivity and moderate specificity.
14:00 - 15:30 Room B
Abdominal Viscera
SS 601b
Efficacy and diagnostic performance
Moderators:
F. Caseiro-Alves; Coimbra/PT
S. Haneder; Mannheim/DE
B-0409 14:00
The correlation study of visceral fat area and non-alcoholic liver disease
in hepatocellular carcinoma
K. Weng, I.-H. Lao, C. Mak, W. Tzeng; Tainan/TW (
[email protected])
Purpose: Visceral fat area (VFA) is a qua ntitative measurement of visceral fat
in CT images. Increased VFA has been postulated as the cause of non-
alcoholic fatty liver disease (NAFLD) in NAFLD-related hepatocellular
carcinoma (HCC). So far, no study has directly validated the hypothesis.
Methods
and Materials: 43 HCC patients with pre-treatment abdominal CT in
Jan/2009-April/2011, without chronic viral hepatitis or alcoholism, were
included. VFA elevation ( > 100 cm
2 at umbilicus level) and fatty liver is
determined in CT images. Prevalence of increased VFA, liver function test
(LFT) at HCC diagnosis, Child-Pugh score, the Cancer of the Liver Italian
Program (CLIP) score, and HCC-related mortality were compared between
patients with and without NAFLD. Further, CLIP staging was compared
between patients with and without elevated VFA.
Results
No statistically significant difference existed in the prevalence of
increased VFA, HCC-related mortality, Child-Pugh score and LFT at HCC
diagnosis, between patients with and without NAFLD. The distribution pattern
of CLIP score was statistically signifi cantly different between NAFLD group and
non-NAFLD group (more CLIP 2, 3 patients in NAFLD group, p=0.047) but not
between HCC patients with and without VFA elevation. The mortality rate in
non-NALFD group is higher than NAFLD group but not statistically significant
(p=0.101).
Conclusion
The results from our study did not support that increased VFA
was associated with LFT, severity of NAFLD, and several prognostic factors in
HCC patients. The difference in mortality and distribution pattern of CLIP stage
in patients with and without NAFLD suggested different prognoses and may
worth further investigation.
B-0410 14:09
The use of bolus tracking, high flow or slow flow contrast injection rate in
Gd-EOB-MRI of the liver and its influence on SNR and truncation artifacts
on arterial phase
G. Perucca, P. Demaria, R. Faletti, D. Righi, P. Fonio, G. Gandini; Turin/IT
(
[email protected])
Purpose: To evaluate signal to noise ratio (SNR) and presence of truncation
artifacts (TA) on arterial phase images in gadoxetic acid-DTPA (Gd-EOB-
DTPA)-enhanced magnetic resonance imaging (MRI) of the liver with and
without fluoroscopic triggering technique using high or slow-rate contrast
injection.
Methods
and Materials: 176 MR examinations for liver disease were
retrospectively reviewed. Three Gd-EOB-DTPA injection methods were
evaluated: 1) fluoroscopic triggering and high-rate injection (2.0 ml/s); 2)
fluoroscopic triggering and slow-rate injection (0.8 ml/s); 3) no fluoroscopic
triggering, high-rate injection and double arterial phase acquisition (2.5 ml/s). A
qualitative analysis was performed, evaluating presence of TA and giving a
score to set the image quality (0: no TA; 1: TA with no diagnostic impairment;
2: TA with diagnostic impairment). As a quantitative analysis, SNR ratio on
arterial phase images was calculated placing ROIs in three liver parenchyma
regions. To evaluate the appropriateness of the arterial phase, mean intensity
values were calculated on abdominal aorta, and compared to values in non-
enhanced phase. T-Student test and ANOVA test were performed for statistical
analysis.
Results
The presence of TA was significantly lower in groups 2 and 3 if
compared to group 1. SNR of liver parenchyma on arterial phase was
significantly higher in groups 2 and 3, in comparison with group 1. The
appropriateness of the arterial phase was similar across groups.
Conclusion
High rate contrast injection without fluoroscopic triggering
technique and double arterial phase acquisi tion is a valid choice for Gd-EOB-
DTPA MR imaging of the liver.
B-0411 14:18
Usefulness of "controlled aliasing in parallel imaging results in higher
acceleration" (CAIPIRINHA) in gadoxetic acid-enhanced liver MRI to
clarify the hepatic arterial phase
Y. Park, C. Lee, K. Kim, J. Choi, J. Lee, C. Park; Seoul/KR
(
[email protected])
Purpose: To determine whether CAIPIRINHA could improve the image quality
in the hepatic arterial phase of gadoxetic acid-enhanced liver MRI.
Methods
and Materials: A total of 320 patients underwent gadoxetic acid-
enhanced liver MRI: a conventional protocol (fixed scan delay and 2 mL/s
injection) using standard 3-T MR (group A); an optimised protocol (bolus
tracking and 1 mL/s injection) using standard 3-T MR (group B); an optimised
protocol using new 3-T MR (group C); and an optimised protocol and
CAIPIRINHA using new 3-T MR (group D). An image quality in the hepatic
arterial phase was reviewed and assigned using a 4-point rating scale from 1
(no artifacts) to 4 points (nondiagnostic images with severe artifacts). The
differences in image quality scores among 4 groups were evaluated.
Results
The median score of image quality was 2 in groups A and B and 1 in
groups C and D. Scores of 4 points were observed in groups A (n = 7), B (n =
5), and C (n = 3), but not in group D. From groups A to D, the median score of
image quality decreased significantly ( P = 0.0001). The median score of image
quality of group D was significantly lower than those of groups A and B ( P =
0.0001 and 0.001, respectively), while there was no significant difference
between groups D and C (P = 0.656).
Conclusion
CAIPIRINHA technique improved the image quality of hepatic
arterial phase imaging with gadoxetic acid, reducing the number of
nondiagnostic arterial phase studies.
B-0413 14:27
Real-time elastography: role in the assessment of hepatic fibrosis in
patients with liver iron-overload
L. Cevasco, F. Paparo, M. Revelli, C. Puppo, E. Aleo, L. Bacigalupo, G. Forni,
G. Rollandi; Genoa/IT (
[email protected])
Purpose: Our purpose was to determine the diagnostic accuracy of real-time
elastography (RTE) in assessing hepatic fibrosis stage in a heterogeneous
cohort of patients with liver iron-overload using transient elastography (TE) as
Methods
and Materials: 67 patients with MRI-detectable hepatic iron-overload
(T2*< 6.3 ms) were enrolled. All TE and RTE examinations were performed by
experienced operators: the informations provided by the elastograms were
converted in quantitative data by calculating the elastic ratio, which represents
the strain distribution in two selected ROI (one positioned in the liver
parenchyma and the other in a homogeneously soft region of the diaphragm).
Results
60 patients were included; 7 patients were excluded because of
invalid TE or RTE examinations. The cohort of patients included 37 adults with
thalassaemia major, 13 patients with thalassaemia intermedia, 6 patients with
primary haemochromatosis and 4 patients with myelodysplastic syndromes. A
significant increase in el astic ratios was observed with increasing stiffness
values measured by TE (r= 0.645, 95% CI 0.468-0.772, P < 0.0001). The
mean elastic ratios for each METAVIR group were as follows: F0/1=1.9± 0.4;
F2=2.2±0.4; F3=2.9±0.5; F4=3.2±0.4. The diagnostic accuracy of RTE for F 2
evaluated by AUC-ROC analysis was 0.798 (95% CI 0.674-0.890). The
diagnostic accuracy of RTE for F 3 was 0.909 (95% CI 0.806-0.968). At a cut-
off 2.75, RTE showed a sensitivity of 70% (95% CI 45.7-88.1) and a
specificity of 97.5% (95% CI 86.8-99.9).
Conclusion
RTE allows to discriminate between F0/1-F2 and F3-F4 with a
reasonable diagnostic accuracy in patients with MRI-detectable liver iron-
overload.
S224
BA C D E F G
Friday
B-0414 14:36
The impact of field strength and contrast administration on liver
haemodynamics at k-t accelerated 4D flow MRI
Z. Stankovic, M. Markl, E. Semaan, M. Wasielewski, M. Carr, A. Barker,
J. Carr, J. Collins; Chicago, IL/US (
[email protected])
Purpose: To evaluate influence of contrast administration and field strength on
visualisation and quantification of arterial and portal venous (PV) liver
haemodynamics at 4D flow MRI in healthy volunteers.
Methods
and Materials: Liver haemodynamics were evaluated on n=38 4D
flow MRI datasets acquired in 5 healthy volunteers (55 ±9 yrs) at 1.5 T and 3 T
with a spatial resolution of 2.1x2.5x3.0 mm 3. Scans were performed before and
after administration of gadofosveset trisodium (Ablavar©). Measurements were
performed with venc=50 and 100 cm /sec. K-t GR APPA was applie d with an
acceleration factor R=5. Qualitative 3D blood flow visualisation was based on
particle-traces and streamlines. Quantitative analyses were performed with
retrospective extraction of time-resolved peak velocities and net flow over the
cardiac cycle based on 10 analyses planes. Bland Altman (BA) analyses
compared peak velocities and net flow.
Results
4D flow MRI visualisation was successful in all datasets. Qualitatively,
increased noise was seen for the PV system evaluation for a venc of 100 cm/s.
Quantitative analyses at 1.5 vs. 3 T revealed similar values for peak velocities
(BA:0.02±0.12 cm/s) and net flow (BA:0.2 ±3.4 ml/cycle). Flow quantification
before and after contrast offered similar values for peak velocities
(BA:0.01±0.05 cm/s), while net flow values were increased with a mean
difference of (BA:-0.6±1.3 ml/cycle) post-contrast.
Conclusion
4D flow MRI enables visualisation of the liver haemodynamics, at
both 1.5 and 3 T, with and without contrast. While quantitation of peak
velocities was similar across field strengths and independent of contrast
administration, statistically signific ant differences were noted in net flow
quantification, likely due better delineation of vessel margins with contrast.
Author Disclosures:
J. Carr: Speaker; Lantheus Speaker Bureau.
B-0415 14:45
Diagnostic capabilities of dual-energy x-ray absorptiometry in the
diagnostic algorithm of the metabolic syndrome in patients with
steatohepatitis
D. Venidiktova, A.V. Borsukov, M.V. Borsukova; Smolensk/RU
(
[email protected])
Purpose: To determine the informational content of x-ray absorptiometry and
non-invasive bioimpedance in patients with mixed origin steatohepatitis.
Methods
and Materials: In 2012, 63 patients with obesity were examined
(men - 38 women - 25) with steatohepatitis: Group 1 (n = 18) - non-alcoholic
fatty liver disease, group 2 (n = 21) - steatohepatitis in patients with 2-type
diabetes, group 3 (n = 24) - alcoholic steatohepatitis. The patients underwent a
bioimpedance and the whole body research with dual energy absorptiometry
(DXA-StratosDR).
Results
At the 1
st stage, the body mass index (BMI), the results of
bioimpedance and densitometric analysis in the system "fat - water" and "fat -
lean mass" of the human body were compared. The diagnostic efficacy of
instrumental methods is 38.6 % higher than BMI information content in all
patients. On the 2
nd stage, the set of measures to reduce weight was hold. In
the first month of the 2 nd stage, with DXA and BIM the water sector of the
organism was decreased in 1 gr. by 18.5 % of the original; in 2 gr. by 27.1%; in
3 gr. by 7.8 %. DXA in 2
nd stage: sensitivity 97.5%, specificity 95.2%;
informative content of BIM was: sensitivity 74.7%, specificity 66.3%.
Conclusion
The method for DXA-"whole body" is more informative in the
diagnosis of metabolic syndrome.
B-0416 14:54
MRI-based estimation of liver function: post-Gd-EOB-DTPA T1
relaxometry of 3 T vs the MELD-Score
M. Haimerl, N. Verloh, C. Fellner, F. Zeman, C. Stroszczynski, P. Wiggermann;
Regensburg/DE (
[email protected])
Purpose: To determine the ability of T1 mapping of liver on Gd-EOB-DTPA-
enhanced MR imaging (MRI) for estimating liver function and to compare the
estimated liver function to the Model for End-Stage Liver Disease (MELD)
score.
Methods
and Materials: 168 patients underwent Gd-EOB-DTPA-enhanced
MRI on a 3 T system. Patients were classified into three groups: MELD-Score
10 (n = 128), MELD-Score 11 - 18 (n = 33) and patients with MELD-Score
> 18 (n = 7). Two TurboFLASH sequences (TI = 400 ms, 1000 ms) were
acquired before and 20 minutes after Gd-EOB-DTPA administration to obtain
T1 maps. Reduction rate of T1 relaxation time between pre- and postcontrast
enhancement and T1 relaxation times were determined and correlated to the
MELD-score.
Results
T1 relaxation time for non-enhanced MRI showed no significant
differences (p = 0.644) between the 3 different groups (MELD 10,
762.62 ms ± 140.28 ms; MELD 11- 18, 783.31 ms ± 169.47; MELD > 18,
802.11 ms ± 204.14 ms). After administration of Gd-EOB-DTPA a significant
difference of patient groups could be shown (MELD 10,
297.72 ms ± 88.41 ms; MELD 11- 18, 430.16 ms ± 134.99; MELD > 18,
561.95 ms ± 90 ms; p 0.001)
Conclusion
Patients with advanced liver disease showed significantly lower
changes in T1 mapping. Therefore, evaluation of changes in T1 mapping of the
liver parenchyma may serve as a useful method to determine whole liver
function, to improve the estimation of segmental liver function and finally to
define the grade of liver disease.
B-0417 15:03
The application research of CT single energy image fusion technology in
hypervascular liver small lesions
M.Y. Wang, B.J. Gao, J.P. Lv; Zhengzhou/CN
(
[email protected])
Purpose: To evaluate the applied value of CT single energy image fusion
technology in hypervascular liver small lesions in arterial phase.
Methods
and Materials: 30 patients who were accepted energy spectra of CT
scans in arterial phase, a total of 48 sma ll rich blood supply of the liver lesions
(炩3 cm), were retrospectively analysed. CT browser binding energy spectrum,
yielding 40keV, 70keV, QC groups, as well as (40+70) keV integration set of
four images. The noise ratio (CNR) and image noise of four groups were
compared using one-way analysis of variance. The lesion detection and the
overall image quality were compared using 5 point method and using
nonparametric tests.
Results
There were no significant differences between the CNR of (40+70)
keV group (6.39 ±4.21) and that of 40keV Group (4.15 ±3.97) (P> 0.05), but the
CNR of (40+70) keV group was significantly higher than that of 70keV Group
(3.28 ±3.02) (p=0.009) and that of QC group (3.23 ±3.41) (p=0.008).The image
noise of (40+70) keV group (25.44 ±6.74) is significantly lower than that of
40keV (46.37 ±9.16) (P < 0.001), but higher than that 70keV Group
(19.33±6.70) (P=0.009) and QC group (16.61 ±3.60) (p 炩0.001). There were
no significant differences between the lesions detection capacity score of
(40+70) keV group (3.36 ± 0.51) and that of 40keV Group (3.5 ± 0.66), but the
lesions detection capacity score of (40+70) keV group was significantly higher
than that of 70keV Group (2.94 ± 0.45) (P=0.016) and that of QC group
(3.06 ± 0.416) (P=0.049). The overall image quality score of the (40 +70) keV
group (3.61 ± 0.53) was significantly higher than that of the other three group
(P < 0.02).
Conclusion
CT single energy image fusion technology which combines the
advantages of high CNR of the low keV image with the advantages of the low
noise of high keV image without compromising image quality, improve the
lesion detection capability.
B-0418 15:12
Cost-utility analysis of nonalcoholic steatohepatitis screening
E. Zhang, C. Wartelle, L. Lepanto, A. Tang; Montreal, QC/CA
(
[email protected])
Purpose: Nonalcoholic fatty liver disease (NAFLD) is the leading chronic liver
condition in Western countries. No studies have examined the cost-
effectiveness of screening for nonalcoholic steatohepatitis (NASH), its
advanced form. We performed a cost-utility analysis of noninvasive screening
and intervention strategies using third-party payer perspective.
Methods
and Materials: A Markov model was created simulating NAFLD
progression in a general population. We compared the most validated
noninvasive techniques for NASH or significant fibrosis ( F2) detection:
transient elastography (TE); acoustic radiation force impulse (ARFI); NAFLD
fibrosis score (NFS); cytokeratin-18 (CK-18); magnetic resonance elastography
(MRE), and sequential algorithms. Liver biopsy and MRE were compared as
confirmation methods. Model parameters were derived from literature review
and uncertainties tested in sensitivity analyses. Costs were calculated in
Canadian dollars adjusted for inflation and discounted at 3%. Incremental cost-
effectiveness ratio (ICER) of $C50,000 or less was considered cost-effective.
Results
Compared with no screening, screening with NFS alone and with
NFS/TE/CK-18 algorithm were most cost-effective with ICERs of $C4,330 and
$C18,200 per quality-adjusted life year (QALY) gained, respectively. Screening
with NFS/ARFI/CK-18 algorithm was dominated with an ICER of $C61,876 per
QALY gained. Compared with biopsy, MRE confirmation for fibrosis staging
was more cost-effective with ICER of $C18,715 vs. $C44,033. Sensitivity
analyses revealed ARFI became more cost-effective than TE in the sequential
algorithms if TE unreliability rates exceeded 21% or when TE price increased
past $C108.
Conclusion
Our model suggests that NASH screening in the general
population can be cost-effective with NFS alone or with a sequential
NFS/TE/CK-18 algorithm.
S225
BA C D E F G
Friday
14:00 - 15:30 Room C
Computer Applications
SS 605
CAD and image segmentation
Moderators:
O. Pianykh; Newton Highlands, MA/US
P. Sögner; Feldkirch/AT
B-0419 14:00
Double reading improves detection of small lung tumours in chest
radiographs: can a computer aided detection system replace the second
reader?
S. Schalekamp
1, C.M. Schaefer-Prokop2, N. Karssemeijer1, B. van Ginneken1;
1Nijmegen/NL, 2Amersfoort/NL (
[email protected])
Purpose: To investigate whether or not a computer aided detection (CAD)
system could replace a second human reader in a double reading process.
Methods
and Materials: We selected 300 posteroanterior and lateral digital
chest radiographs (CXR), including 111 with a solitary CT proven pulmonary
nodule with an average diameter of 16 mm. Twelve radiologists read the CXRs
having bone suppressed images available. Readers marked and scored
suspicious regions on a continuous scale from 0 to 100. All images were also
processed by a CAD system (ClearRead+Detect 5.2, Riverain Technologies)
that also provided a score between 0 and 100 for each suspicious location it
identified. Location based ROC analysis was used to measure nodule
localisation performance. Mean sensitivity in a false positive fraction range
between 0 and 0.2 was used to compare reader performance. Double reading
was evaluated by combining the findings of two readers: scores of findings at
the same location were averaged while findings that were not identified by the
second observer were averaged with 0. CAD results were treated similarly to
every observer for simulated double reading. A paired t-test was used to
calculate differences.
Results
The mean sensitivity was 64.0% for single reading (range 45.5%-
78.2%). Combining the readings of two observers improved lung nodule
detection on average to 73.1% (range 58.3%-83.8%; p=0.001). Performance
with CAD as the second reader increased to 67.8% (range 58.1%-81.1%;
p=0.02).
Conclusion
Use of CAD as the second reader significantly improves
detection of lung nodules, although it is not yet as good as double reading by
two human readers.
Author Disclosures:
S. Schalekamp: Research/Grant Support; Riverain Technologies. C.M.
Schaefer-Prokop: Advisory Board; Riverain Technologies. N. Karssemeijer:
Research/Grant Support; Riverain Technologies.
B-0424 14:09
Visceral fat quantification using routine abdominal CT data
M. Pop, R. Pop; Tg.Mures/RO (
[email protected])
Purpose: Quantitative assessment of body fat is important for the diagnosis
and treatment of diseases related to obesity. The standard evaluation methods
do not measure body fat quantitatively. Computed tomography (CT) is
becoming the standard procedure for measuring the abdominal fat distribution,
various methods and software being used.
Methods
and Materials: The retrospective study included 111 inpatients, who
underwent routine abdominal CT exams (SOMATOM AS 64 MDCT). MPR
linking the posterior-inferior aspect of L4/L5 intervertebral disc and the
umbilicus were processed using custom written MATLAB R2009b software.
ImageJ was used for tracing the contour of visceral fat area (VFA).Patient data
(including blood glucose, cholesterol an d triglycerides) were statistically
analysed using MO Excel and GraphPad Inprism5.
Results
The Visceral Fat percentage varied in population from 14.59-
68.69 (SD= 11.83) with significant difference between sexes (male vs. female,
46.98vs.31.62, p 220 mg% and triglycerides > 150 mg% are significantly
associated with the VF percent (p < 0.05).Overall there is a weak correlation
between the lab variables and the measured fat, the strongest one being
between TG and the VFA (r=+0.23). However, when looking at certain samples
there is a higher positive correlation between age and VFA percentage.
Conclusion
The technique used decreases the human error in marking of the
fat areas providing a good estimation of the VF and VF percentage. Visceral fat
measured by CT relates with certain lab variables. Further analysis, including
different blood tests and clinical data are required for a better understanding of
the CT role in obesity related pathology diagnosis and treatment.
Author Disclosures:
M. Pop: Grant Recipient; Internal Research Grant- Tg.Mures University of
Medicine and Pharmacy, Romania. R. Pop: Grant Recipient; Internal Research
Grant- Tg.Mures University of Medicine and Pharmacy, Romania.
B-0420 14:18
Application of artificial neuronal networks for the assessment for the
assessment of early, non-invasive breast cancer
M. Dietzel1, W.A. Kaiser2, P.A.T. Baltzer3; 1Erlangen/DE, Jena/DE, 2Jena/DE,
3Vienna/AT, Jena/AT
Purpose: Accurate diagnosis of breast cancer at an early, non-invasive stage
is crucial for favourable patient outcome. Breast-MRI provides significant
potential to solve this task. However, eve n upon breast-MRI differentiation of
non-invasive breast cancer from benign fibrocystic breast changes remains
challenging. Artificial neuronal networks (ANN) are able to automatically
classify highly sophisticated imaging data. Accordingly, we evaluated the
potential of ANN for the diagnosis of early, non-invasive breast cancer based
on MRI imaging patterns.
Methods
and Materials: Patients were recruited from a cross-sectional
database containing consecutive, histological ly verified breast lesions imaged
by breast-MRI (standardised protocols; ethical-board approval). All non-
invasive breast cancer (DCIS: ductal carcinoma in situ) or benign findings
(FBC: fibrocystic breast changes) were included into the dataset of the study.
In a next step, imaging patterns of FBC and DCIS were prospectively
evaluated by two experienced radiologists in consensus using 17 standardised
descriptors. Finally, non-supervised ANN we re applied to classify each lesions
as "benign" or "malignant" based on the breast-MRI descriptors. To further
optimise the ANN performance, topology and network-architecture were
optimised using dedicated heuristics in a randomly selected training sample.
Diagnostic accuracy of the ANN was then prospectively evaluated in a
separate test sample (AUC: Area under the curve).
Results
288 patients were included into the dataset. 69 were diagnosed with
DCIS. Diagnostic accuracy was highest, if a multilayer perceptron type ANN
was used (AUC= 86.2%).
Conclusion
Artificial neuronal networks provide high diagnostic accuracy for
the assessment of breast cancer at an early non-invasive stage.
B-0421 14:27
Real time and accurate segmentation of mammographic
microcalcifications
N. Arikidis, P. Sakellaropoulos, S. Skiadopoulos, A. Karahaliou, K. Vassiou,
L. Costaridou; Patras/GR (
[email protected])
Purpose: Morphology of individual microcal cifications contributes in the
characterisation of microcalcification clusters in mammography. Precise
segmentation is thus essential for the development of computer-aided
diagnosis (CAD) schemes. The purpose of this study is the development of a
Method
for fast and accurate segmentation of individual microcalcifications,
fulfilling requirements of a content-based image retrieval CAD scheme.
Methods
and Materials: A two-stage segmentation method was developed.
Initially, the grey-level value corresponding to the maximum radial gradient
index (RGI) is estimated in polar coordinates, providing initial contour pixel
estimates. The RGI contour is then defined in Cartesian coordinates using a
first-order polynomial fitting of the contour pixel estimates. Finally, the contour
is optimised by iterative region growing, allowing curve evolution from inside
the lesion. The proposed method was compared with a radial gradient-based
segmentation method. Segmentation accuracy was quantitatively evaluated
employing the area overlap measure, by comparing automated segmentations
to expert manual delineations of 158 indi vidual microcalcifications originating
from 24 clusters of the DDSM database. Microcalcifications spanned a wide
range of shapes and sizes and background mammographic parenchyma. The
Method
functionality was qualitatively assessed by incorporating it in a home-
developed GUI.
Results
The proposed method achieved an area overlap of 0.66 ±0.20,
outperforming statistically significantly ( p
< 0.001) the radial gradient-based
Method
(0.44 ±0.17), and fulfilled radiologists' requirements for accurate and
real-time segmentation of microcalcifications.
Conclusion
The proposed segmentation method is time-efficient and non-
parametric, performing accurately in case of microcalcifications of varying
shape and size, even in presence of dense parenchyma.
S226
BA C D E F G
Friday
B-0422 14:36
Automatic detection of prostate cancer by computer-aided multi-
parametric magnetic resonance imaging
S. Mazzetti, V. Giannini, A. Vignati, F. Russo, D. Regge, M. Stasi; Candiolo/IT
Purpose: A computer-aided diagnosis (CAD) system was developed, to
increase objectivity and reproducibility of prostate cancer (PCa) interpretation
in multi-parametric (mp) magnetic resonance imaging (MRI). T2-weighted (T2-
w), diffusion-weighted (DW) and dynamic contrast-enhanced (DCE)
parameters were combined to calculate a pixel-wise probability of PCa
presence.
Methods
and Materials: 20 men with PSA > 4 ng/ml with biopsy proven PCa
underwent MRI at 1.5 T using an endorectal coil, followed radical
prostatectomy within 3 months of imaging. Each prostate was cut into axial
sections of the same thickness and orientation as the axial MRI. Foci of cancer
were contoured on each slide with ink by the pathologist to create the standard
of reference. A radiologist compared imaging with histopathology and reported
both malignant and benign regions of interest on T2-w images. After the
registration between T2-w, DW and DCE datasets, each pixel was represented
like a vector containing scalar values such as T2-w signal intensity, the
apparent diffusion coefficient and quanti tative physiological parameters (e.g.
kep, Ktrans) obtained from DCE-MRI datasets. All these parameters were fed
into a support vector machine (SVM) classifier, and a parametric color-coded
map of the cancer's presence probability for each pixel of the prostate was
created.
Results
The area under the ROC curve for the SVM classifier was equal to
0.93, sensitivity 0.84 and specificity 0.85.
Conclusion
The application of a CAD system based on MRI information that
automatically highlights cancer suspicious regions will improve the diagnostic
accuracy of the radiologist, reducing reader variability and speeding up the
reading time.
B-0423 14:45
Automatic segmentation of atherosclerotic plaque components in
different carotid MRI protocols
A. van Engelen1, A.C. van Dijk1, M.T.B. Truijman2, R. van 't Klooster3,
A. van der Lugt1, W.J. Niessen1, M.E. Kooi2, M. de Bruijne1; 1Rotterdam/NL,
2Maastricht/NL, 3Leiden/NL (
[email protected])
Purpose: To automatically segment carotid atherosclerotic plaque
components in MR image data from two hospitals with a difference in MRI
pulse sequences and MRI scanners. Additionally, to evaluate whether a
Method
trained on data obtained with one imaging protocol can be used to
segment data that is obtained with another protocol.
Methods
and Materials: Multi-sequence MRI (T1w, T2w, IR-TFE or SPGR,
TOF or FSPGR, postcontrast-T1w) of 19 patients from center 1 and 20 from
center 2 (stenosis 30-69%) were acquired. Observer 1 manually annotated all
39 images; observer 2 only those of center 1. Using the annotations of
observer 1, linear discriminant classifiers for calcification (C), lipid or
intraplaque haemorrhage (L+IPH) and fibrous tissue (F) were trained with 2
Methods
M1) using only same-center data and M2) using only different-center
data. Evaluation was performed using leave-one-patient-out experiments.
Results
ICC-values (volume per vessel) of F, L+IPH and C, were for M1 0.98,
0.90 and 0.60 (center-1) and 0.96, 0.91 and 0.94 (center-2), and for M2 0.87,
0.89 and 0.09 (center-1) and 0.97, 0.94 and 0.81 (center-2). Interobserver-ICC
for center 1 was 0.91, 0.53 and 0.63. Kappa for IPH-detection was 0.80 and
0.89 (M1), 1.00 and 0.71 (M2), and 0.78 between observers.
Conclusion
Automated segmentation of atherosclerotic plaque components
was similar to the interobserver variability. Using an algorithm trained on data
from a different center reduced accuracy for calcification and, for center 2, IPH
detection. Either standardised imaging protocols, or advances in image
processing to deal with different image acquisitions, are recommended.
Author Disclosures:
A. van Engelen: Research/Grant Support; CTMM, the Center for Translational
Molecular Medicine (www.ctmm.nl), project PARISk (grant 01C- 202), and the
Dutch Heart Foundation. A.C. van Dijk: Research/Grant Support; CTMM, the
Center for Translational Molecular Medicine (www.ctmm.nl), project PARISk
(grant 01C- 202), and the Dutch Heart Foundation. M.T.B. Truijman:
Research/Grant Support; CTMM, the Center for Translational Molecular
Medicine (www.ctmm.nl), project PARISk (grant 01C- 202), and the Dutch
Heart Foundation. R. van 't Klooster: Research/Grant Support; CTMM, the
Center for Translational Molecular Medicine (www.ctmm.nl), project PARISk
(grant 01C- 202), and the Dutch Heart Foundation.
B-0425 14:54
Computer-assisted diagnosis (CAD) in multiparametric neuroimaging:
you only have to push the button?
M. Dietzel1, S. Lang1, P.A.T. Baltzer2, B. Volbers1, S. Lettmaier1, R. Fietkau1,
T. Struffert1, T. Engelhorn1, A. Dörfler1; 1Erlangen/DE, 2Vienna/AT
Purpose: Multiparametric magnetic-resonance neuroimaging is increasingly
used in clinical practice. From theory, it provides quantitative measures for
tissue characterisation and might - beside many other benefits - potentially
reduce observer related bias. Yet, currently available CAD-software requires
numerous user-interactions. Consequently, relevant observer-related bias on
final results can not be excluded. We aimed to systematically address this
matter using a state of the art MR protocol and a CAD-software, specifically
designed for this purpose.
Methods
and Materials: A series of fifteen patients with brain tumours was
investigated using one clinical MR unit (Siemens Magentom Aera, B
0=1.5T)
including DTI (Diffusion tensor imaging), DWI (Diffusion weighted imaging) as
well as DCE sequences (dynamic contrast enhanced; 6 ml Gadovist @2 ml/s).
Multiparametric analysis was done by one experienced neuroradiologist using
a commercially available semi-automatic CAD-software. Postprocessing was
repeated independently several times resulting in serial measurements of FA
(DTI), ADC (DWI), k
trans, k ep and V e (DCE). Variability within serial
measurements was assessed by reproducibility (concordance correlation-
coefficient), precision (Pearson ;), accuracy (Bias correction-factor/Cb),
reliability (intraclass correlation-coefficient) and systematic bias (Bland-Altmann
plot: regression-coefficient/Rc).
Results
Overall variability of multiparametric analysis was low.
Reproducibility, precision, reliability and accuracy showed a range from 0.94 to
0.99. Best results were identified for DCE-parameters (reproducibility,
precision, reliability and accuracy: 0.99). In all series, Bland-Altmann plot
excluded presence of systematic bias.
Conclusion
Computer-assisted multiparametric Neuroimaging was a robust
measure for tissue characterisation. Despite significant user interaction during
the CAD-analysis, we identified excellent reproducibility, precision and
absence of systematic bias.
B-0426 15:03
An enterprise class computer aided detection platform scalable from
laptop to cloud
M. Hinton
1, O. Kubassova1, M. Boesen2; 1London/UK, 2Copenhagen/DK
(
[email protected])
Purpose: To achieve efficiency in analyzing medical images many utilise cloud
based image storage and computer aided detection (CAD) techniques. The
problem is keeping calculations and image overlays up to date whilst providing
good user experience across uncontrolled bandwidths. To support clinical
developments the architecture of the software should support easy integration
of new algorithms without compromising performance. Here is a novel
approach to a multi-tier architecture, Dynamika, which has addressed these
problems and been validated in radiology practices.
Methods
and Materials: Dynamika uses a back end framework of Spring and
Hibernate to give robust server scaling and performance. It uses Spring
Webflow to control the path through the application. Webflow has been
enhanced for tightly controlled batch processing, utilised in clinical trials,
routine analysis, and investigations. The front end uses Google Web Toolkit to
give high performance, desktop like behavior through AJAX and the power of
HTML5. 3D is with WebGL.
Results
We have benchmarked against a workstation for user experience and
development efficiency. The cloud arch itecture has comparable performance to
the workstation in scrolling through images with complex overlays. Time to
implement new algorithms (coding and testing) was up to 10 times less in
Dynamika. Dynamika supports collaboration and can be used from any device.
Conclusion
Dynamika has addressed challenges of handling large datasets
in real-time. Validation in clinical practice has shown Dynamika gives better
performance than a workstation. It supports multi-center collaboration and data
sharing. There are low costs to deploy updates and development time is less.
Author Disclosures:
M. Hinton: Employee; Image Analysis. O. Kubassova: CEO; Image Analysis.
M. Boesen: Advisory Board; Independant non paid member Image Analysis
LTD. Consultant; Radiologist.
S227
BA C D E F G
Friday
B-0427 15:12
Automatic assessment of the occlusal plane on panoramic radiographs.
P.A. Regulski, K. Szopiski, K. Nowiski; Warsaw/PL (
[email protected])
Purpose: Objective assessment of the curvature of occlusal plane with the use
of an automatic computer algorithm.
Methods
and Materials: 100 panoramic radiographs were selected and
divided by two observers into two equinumerous groups (Kappa = 1): a correct
occlusal plane position (x-ray meets quality criteria) and an incorrect occlusal
plane position (x-ray does not meet quality criteria). The segmentation
algorithm based on clustering methods with adaptive thresholding was
performed to find region of interest (teeth and space between them). This
region constituted starting points for watershed segmentation. Skeletonization
was carried out on segmented surfaces. Lines and points of the skeleton were
smoothed with polynomial interpolation. For each x-ray, parametric angle of
occlusal plane was calculated by usi ng the mean of the derivatives in
equidistant points located on the interpolated line.
Results
Magnitudes of parametric angles formed two Gaussian curves: one
for panoramic radiographs meeting quality criteria (average = 15.97, standard
deviation = 7.81), the other for ones the does not (average = 28.96, standard
deviation = 9.21). By that means the thresholding value was obtained ( ' =
22.83, p < 0.05).
Conclusion
Automatic assessment of the curvature on orthopantomograms of
occlusal plane is feasible and the objective thresholding value of this curvature
is 22.83.
B-0428 15:21
Enhancing ground glass nodule interpretation through the interactive
unification of 2D and 3D visualisations
P. Kocsis, V. Demers, F. Chandelier, L.A. Stein; Montreal, QC/CA
(
[email protected])
Purpose: To demonstrate the advantage of a Novel visualisation technique
that interactively blends 2D and 3D renderings for the interpretation of ground
glass opacity nodules (GGO). We hypothesise that using such technique for
GGO examination will allow an improvement in image accuracy in terms of
diagnostic information when compared to traditional thick-slab multiplanar
visualisation (SLAB).
Methods
and Materials: 13 patient datasets were obtained from The Cancer
Imaging Archive (http://cancerimagingarchive.net/) sponsored by the Cancer
Imaging Program, DCTD/NCI/NIH. Interactive screen capture images of
nodules were collected for both visualis ation paradigms. Our primary objective
was to evaluate the discriminative power of light intensity values within a given
region of interest to best segregate GGO from its environment. The signal to
noise ratio (SNR) was determined for all images and compared to a Rose
Criterion (RC) that represents the 100% certainty threshold for identification of
image details (corresponding to RC (SNR) 5).
Results
The SNR of GGO exceeded the Rose Criterion (SNR 5) in 92.3%
and 46.2% of the patient datasets during the Novel and SLAB visualisation
conditions respectively. Qualitative inspection of the GGO in the former
ensured that vessels were not included in nodule volume assessments.
Conclusion
The Novel visualisation technique increases accuracy of image
details, by providing an interactive environment integrating traditional SLAB
visualisation and advanced 3D rendering . This facilitates radiologist's
interpretation while characterising GGO nodules. Such results will be
investigated during a prospective clinical study.
Author Disclosures:
P. Kocsis: Employee; Cadens Medical Imaging. F. Chandelier: Employee;
Cadens Medical Imaging.
14:00 - 15:30 Room D
Chest
SS 604
Radiation dose and techniques in chest CT
Moderators:
P. Vock; Spiegel/CH
N.N.
B-0429 14:00
Are chest radiographs outdated in tuberculosis screening? Low dose CT
(LDCT) as an alternative
S. Notohamiprodjo, U.G. Mueller-Lisse, H. Schulze-Koops, M.F. Reiser,
T. Saam; Munich/DE (
[email protected])
Purpose: To rule out tuberculosis before initiation of immunosuppressive
therapy with biologicals, chest X-ray (cXR) is routinely used in rheumatic
patients. We evaluated the diagnostic value of cXR in the detection of pleural
scarring (PS) and postspecific changes (PC) compared to Low-Dose-CT
(LDCT) of the chest as gold standard.
Methods
and Materials: We retrospectively included 80 patients having erect
cXR and LDCT of the chest performed within 2 weeks between 2009 and
2013. One blinded radiologist evaluated the presence/absence of PS and PC
in LDCT independently from a second blinded radiologist who evaluated the
cXR. Cohen´s kappa, Sensitivity (SN), specificity (SP), positive predictive value
(PPV) and negative predictive value (NPV) and accuracy (AC) were calculated.
Dose parameters were recorded.
Results
For detection of PS cXR result ed in SN, SP, PPV, NPV and AC of
53.7%, 96.6%, 92.3%, 27% and 77.9%, respectively. For detection of PC cXR
resulted in SN, SP, PPV, NPV and AC of 50%, 98.3%, 90%, 86.6% and 87%,
respectively. Agreement between cXR and LDCT was moderate with a
Cohen's kappa value of 0.53. The average effective dose was 0.08 mSv in XR
and 0.55 mSv in LDCT.
Conclusion
Our study showed that a substantial number of PC and PS are
missed on conventional chest X-rays which might pose a potential risk for
patients receiving immunosuppressive therapy. LDCT can reveal such post-
specific changes at acceptable radiation dose and might therefore be an
alternative imaging method to rule out postspecific changes.
B-0430 14:09
Thoracic lymph node delineation at contrast-enhanced MDCT:
comparison of protocols with greatly reduced dose ( << 1mSv) and
standard dose
M. Paolini, K. Weber, M.F. Reiser, A. Tufman, R. Huber, U.G. Mueller-Lisse;
Munich/DE (
[email protected])
Purpose: To determine differences in the delineation of mediastinal and hilar
lymph nodes at contrast-enhanced MDCT between a dose-reduced ( < 1mSv,
LDCT) and a standard-dose (SDCT) protocol.
Methods
and Materials: Based on the international-association-for-the-study-
of-lung-cancer (IASLC) grouping of thoracic lymph nodes, two independent
radiologists (respective post-graduate work experience, 3 and 20 years)
retrospectively assessed lymph-node delineation ("measurable" vs. "non-
measurable") in intravenously contrast-enhanced (average, 70 ml at 3 ml/s,
with 350 mg-of-iodine/ml) MDCT-scans of the chest (64 rows, 120KVp, dose
modulation, filtered back projection, reformatted axial slice thickness, 5 mm),
including 9 subsequent LDCTs (effective-tube-current-time-product,
< 30 mAs/slice, effective-dose, < 1mSv) and 36 matched SDCT controls
(average, 100 mAs/slice, with matching for gender, age, chest/lung diameters,
and clinical history) that were obtained during the 4
th quarter, 2012. Fisher's
exact test (p < 0.05) and Cohen's kappa statistics were applied.
Results
Inter-observer agreement was substantial to perfect (kappa: 0.75 -
1.0) for all thoracic lymph node groups (upper mediastinal, aortopulmonary,
subcarinal, lower mediastinal, hilar, peripheral). Overall, LDCTs delineated 47
of 54 (87%) lymph node groups (positive inter-observer agreement), while
SDCT delineated 174 of 216 (81%). There were no significant differences in
individual lymph node groups (p=0.08 to 1.0). Measurable lymph nodes did not
differ significantly in size between cases and controls.
Conclusion
Delineation of mediastinal and hilar lymph node groups was
similar despite greatly reduced-dose at LDCT of the chest-CT when compared
with standard dose chest-CT. Patients with non-malignant lung disease,
unclear chest-X-ray findings, or the need for follow-up CT scans may therefore
benefit from contrast-enhanced LDCT.
S228
BA C D E F G
Friday
B-0431 14:18
Model based iterative reconstruction: its efficacy in CT assessment of
cystic fibrosis and dose reduction
K.K.-P. Lau1, D. Jackson1, N. Ardley1, T. Lau2; 1Melbourne/AU, 2Brisbane/AU
(
[email protected])
Purpose: There is lack of a precise correlation between the chest radiographic
(CXR) findings and the clinical manifest ations of cystic fibrosis (CF). CT chest
is contrarily more sensitive and specific, but routine use is limited by higher
radiation dose (RD). Recent advent of the CT model-based iterative
reconstruction (MBIR) technique improves low contrast detectability and
reduces artifacts at significantly lower radiation dose. This prospective study
was to evaluate the efficacy of MBIR in CT assessment of cystic fibrosis at
much reduced RD.
Methods
and Materials: CT chest at 100 kVp and 4 mAs were undertaken on
consecutive acute adult CF patients. RD's were recorded. MBIR was used to
produce CT images in standard formats. These images and CXR were
individually read by 2 blinded radiologists. Results were compared.
Results
82 patients (M:F=35:47, mean age of 34) were recruited. 29.3%
patients had follow-up CT's. Images were generally 'noisy' but adequate. The
RD's ranged between 0.042 to 0.07mSv which were comparable to one chest
x-ray dose. CT demonstrated bronchiectasis and peribrochial thickening in
100%, mucous plugging in 82.9%, consolidation and tree-in-bud appearances
in 54.8%, collapse in 4.8%, scarring in 42.6%, pneumothorax in 1.2% and
pulmonary abscess in 3.65% of these patients. CXR only detected 68.3%,
4.9%, 14.6%, 1.2%, 24.3%, 1.2% and 0% of these abnormalities
correspondingly. Follow-up CT's accurately monitoring abnormalities.
Conclusion
Gene therapies being developed for CF require detailed lung
evaluation. MBIR helps lowering CT chest RD to that of CXR. CT may become
the preferred imaging tool in CF assessment.
B-0432 14:27
Sources of variability in the quantification of CT perfusion of the lung in
patients with idiopathic pulmonary fibrosis (IPF)
C.J. Rofe, E.J.R. van Beek, N. Hirani, J.T. Murchison, A. Nania, M. Connell,
S. Mirsadraee; Edinburgh/UK (
[email protected])
Purpose: To assess sources of variability of lung perfusion quantified by
means of dynamic CT perfusion.
Methods
and Materials: : Two dynamic pulmonary CT perfusion (DCTP)
scans were obtained in 8 patients with IPF during breath-hold using a Toshiba
Aquilion-One. Perfusion was quantified by maximum-slope technique. Mean
perfusion values were compared between 2 scans on identical regions of
interest in each lung at three pre-determined levels. Intraobserver and
intramodality variability was assessed. < 30% variation was determined as
clinically acceptable.
Results
Observed means in the 16 scans ranged from 57 to
537.3 mls/100 g/min. There was intraobserver agreement (variability < 10%; r2
= 0.98 - 0.74). Clinically acceptable intramodality variations were observed in 5
of 8 patients. Clinically unacceptable variation was seen in 3 patients (up to
98% difference in mean values). Breathing motion artefact was a major source
of intramodality variation. Adjusting for breathing artefact reduced variations in
observed means (reducing the maximum variation by 4% and the average
variation by 22%). Changes in the characteristics of the input function (e.g.
high pulmonary time-density baseline values and different curve slope) were
also sources of measurement bias. Effect of lung density change due to
different depth of breath-hold was minimal. Despite significant variation
between the patients 2 scans, the ratio of values between the 2 lungs in both
scans remained relatively constant.
Conclusion
DCTP provides a physiological mean to assess pulmonary
perfusion. Post-processing analysis of the results is challenging and
awareness of the pitfalls is necessary to apply the tests in clinical trials.
B-0433 14:36
Effectiveness of an automated tube potential selection tool in contrast
enhanced thoracic staging CT examinations
C. Schabel, M. Bongers, S. Mangold, C.D. Claussen, C. Thomas;
Tübingen/DE (
[email protected])
Purpose: To evaluate a novel automated scanogram-based voltage selection
tool (AkV) combined with automated tube current adaptation for thoracic
computed tomography in terms of objective image quality and potential
radiation dose reduction.
Methods
and Materials: Three months after AkV (CAREkV, Siemens,
Forchheim, Germany) was introduced into clinical routine in our institution,
patients who had received a previous thoracic CT examination with 120 kV and
a follow-up exam using AkV were retrospectively included. Besides AKV, all
other scanning parameters were kept constant. Contrast dose was individually
determined. Patients with identical tube potentials in both examinations were
excluded. Contrast-to-noise ratios (CNR) were assed in multiple slices within
the thoracic aorta at identical levels with in each patient. Cross-sections were
measured to document patients cross sectional areas. The effective radiation
dose (ED) was estimated as the product of the dose-length product (DLP) and
a chest specific conversion coefficient (k=0.014 mSv/(mGy*cm)).
Measurements were statistically treated as paired samples.
Results
Forty-eight patients (35 female, 51.0 ±14.0 years) were included. In
arterial phase thoracic imaging, CNR was constant for AkV vs. 120 kV in the
descending aorta (18.8 ±5.6 vs. 19.3 ±6.1; p=0.56) and pulmonary artery
(21.0±6.2 vs. 21.8 ±6.2; p=0.33). ED was significantly lower using AkV
(3.15±1.3mSv vs. 4.1 ±1.3mSv; p < 0.001). Cross-sections (2346 ±509 cm^2 vs.
2343±498 cm^2; p=0.91) and volume of contrast media (86.25 ±12.8 ml vs.
89.4±16.3; p=0.15) did not differ significantly.
Conclusion
Compared to standard 120 kV-protocols, AkV leads to a relevant
radiation dose reduction in contrast enhanced thorcic CT examinations while
CNR of both techniques remains equal.
B-0434 14:45
Artefact reduction of dual-energy lung perfusion image using a tin filter: a
phantom study and evaluation on clinical images
T. Kawai, Y. Ozawa, T. Suzuki, K. Ohashi, Y. Shibamoto; Nagoya/JP
(
[email protected])
Purpose: To investigate the reliability of lung perfusion blood volume (PBV)
images created by dual-energy CT (DECT) equipped with or without a tin filer,
focusing on its accuracy adjacent to high attenuation areas.
Methods
and Materials: A columnar phantom made of hollow resin clay
containing 4.0 mgI/cm^3 with agarose gel containing 50 mgI/mL in the center
(73 and 18 mm in diameter, respectively) was used to simulate contrast-
enhanced lung parenchyma and central veins, respectively. It was scanned by
DECT at 80/140 kVp with or without a tin filer and examined the area of
enhancement decline adjacent to the central high-attenuation gel on the lung
PBV images. In the clinical study, 40 patients (mean age, 65; range, 16 to 93
years) without apparent pulmonary embolism were included. They underwent
DECT with (n = 20) or without (n = 20) the filter and the degrees of artifact -
pulmonary enhancement defect and pseudo-enhancement in the trachea
adjacent to the vena cava were evaluated using a four-point scale (0 = minimal
to 3 = prominent).
Results
In the phantom study, the areas with less than 95% enhancement
compared to the maximum values were 87.6 and 162 mm^2 with and without
filter, respectively. In the clinical study, the mean degrees of artifact with vs.
without filter were 0.85 ±0.58 vs. 2.0 ±0.8 (p < 0.0001) and 1.1 ±0.5 vs. 2.2 ±0.7
(p < 0.0001) for pulmonary enhancement defect and pseudo-enhancement in
the trachea, respectively.
Conclusion
The quality of dual-energy lung perfusion image will be improved
by using the tin filter technique.
B-0435 14:54
Minimising dose in test bolus CT pulmonary angiography (CTPA): can
tube potential be routinely lowered to 80 kVp during contrast monitoring?
J.C.L. Rodrigues, D. Joshi, S. Lyen, I. Negus, N.E. Manghat, M. Hamilton;
Bristol/UK (
[email protected])
Purpose: Technological advances have dramatically reduced CTPA dose.
However, the monitoring phase represents increased proportion of overall
dose. We aimed to determine whether monitoring in test-bolus CTPA can be
routinely performed at 80 kVp to minimise dose without affecting diagnostic
quality.
Methods
and Materials: Retrospective analysis of two test bolus CTPA
protocols was performed. Fifty consecutive patients scanned with protocol A
(low monitoring kVp: 80 kVp and 45 mAs) were compared to fifty consecutive
patients scanned with protocol B (standard monitoring kV: 100 kVp and
45 mAs). Diagnostic phase parameters were the same for both (100 kVp and
150 reference mAs). Scans were assessed for quality (mean attenuation,
signal to noise (SNR) and contrast to noise (CNR) in the main pulmonary artery
(MPA), percentage of diagnostic scans ( > 200 HU in MPA) and number of
repeated monitoring scans). Mean effective dose was calculated.
Results
No difference in mean MPA attenuation (415.5 ±35.8 HU vs
410.1±29.9 HU, P=0.820), SNR (11.0 ±0.9 vs 10.8 ±0.9, P=0.819) or CNR
(9.1±0.9 vs 9.0 ±0.9, P=0.855) between protocols. Diagnostic rates (96% vs
100%, P=0.741) and number of repeated monitoring scans (0% vs 0%) were
similar. Mean monitoring phase dose was significantly lower (0.07 ±0.01 mSv
vs 0.15±0.02 mSV, P
< 0.0001) for protocol A, accounting for 3.2% of the total
CTPA study dose compared with 6.8% in Protocol B.
Conclusion
Monitoring should be performed at 80 kVp in test bolus CTPA to
significantly lower dose, without compromising diagnostic quality. Increased
image noise can be tolerated because the monitoring images are not required
for diagnosis and contrast kinetics can still be reliably determined.
S229
BA C D E F G
Friday
B-0436 15:03
SubmSv CT imaging of pulmonary arteries using an iterative model
reconstruction algorithm
D. Muenzel1, T. Koehler2, B. Brendel2, K. Brown3, S. Zabic3, A. Fingerle1,
E.J. Rummeny1, M. Dobritz1, P.B. Noel1; 1Munich/DE, 2Hamburg/DE,
3Cleveland, OH/US
Purpose: To investigate the improvement in diagnostic quality of iterative
model reconstruction (IMR) algorithm for submSv computed tomogr aphy
angiography of the pulmonary arteries (CTA).
Methods
and Materials: Eighteen patients with CTA were included, 8 with and
10 without pulmonary artery embolism. All scans were performed at 120 kVp
(average effective doses 4.34 ±1.99mSv). Acquisitions with reduced radiation
exposure were simulated from the original CT data to 15% of the tube current,
resulting in a submSv average dose of 0.65 ±0.30mSv. Filtered backprojection
(FBP) was used to reconstruct the original data (protocol A); submSv data
were reconstructed using FBP (protocol B) and IMR (protocol C). Image
quality, image noise and contrast tonoise ratio (CNR) were assessed. Two
blinded readers determined subjective image quality and assessed the
detectability of pulmonary artery embolism.
Results
With IMR noise could be subjectively removed, while the image
texture of these images differed from FBP reconstructions. Specifically, with
IMR, the noise was significantly reduced by a factor up to 20 (B vs. C). CNR
and image quality were improved with a median image quality score of 3
(IMR,B) vs. 1 (FBP,C),p < 0.05. With respect to diagnostics protocol A and C
were identical, while B was worse: To detect pulmonary artery embolism in
IMR and FBP low dose images, the sensitivity was 100% for IMR and 62.5%
for FBP while specificity was 100% for both protocols.
Conclusion
This simulation study indicates that by using IMR, pulmonary
artery embolism can be detected accurately in scans with submSv dose levels.
Author Disclosures:
T. Koehler: Employee; Philips. B. Brendel: Employee; Philips. K. Brown:
Employee; Philips. S. Zabic: Employee; Philips.
B-0437 15:12
Pulmonary CT angiography: evaluation of high concentration contrast
medium protocols for radiation dose reduction
P. Heusch
1, R.S. Lanzman1, J. Aissa1, L. Schimmöller1, G. Antoch1, M. Krix2,
P. Kröpil1; 1Düsseldorf/DE,
2Konstanz/DE (
[email protected])
Purpose: A high iodine delivery rate (IDR) yields a high signal in CT
angiography (CTA), potentially compensating for a reduced radiation dose. The
present study evaluates the combination of a high IDR with a low tube current
time product for pulmonary CTA.
Methods
and Materials: One-hundred nineteen consecutive patients
undergoing pulmonary CTA for suspected pulmonary embolism were included
and imaged on a 128-row CT scanner at 100 kVp using highly concentrated
contrast material (85 ml Iomeprol; 400 mg iodine/ml). The protocol entailed a
flow rate of 5 ml/s and 90 mAs for group A, 3.5 ml/s and 135 mAs for group B,
5 ml/s and 135 mAs for group C, and 3.5 ml/s and 90 mAs for group D. SNR
and CNR were determined for the pulmonary artery. Subjective image quality
(IQ) was rated on a 5-point-scale (1_non-diagnostic IQ - 5_excellent).
Results
CNR did not differ significantly between group A (43.7 ±27.7), B
(34.5±17.9) and C (38.9 ±13.8) as well as between group B and D (29.9 ±11.2).
CNR in group A and C was higher than in group D (p < 0.02). Subjective IQ in
group A (4.7± 0.47) was higher than in group B (4.33 ±0.76) and D (4.41 ±0.5)
(p < 0.05).
Conclusion
A high IDR (highly concentrated contrast material combined with
a high flow) permits a mAs-reduction of approximately 33% without
compromising image quality in pulmonary CTA. Therefore the concept of "high
IDR - low mAs" can be recommended in patients with suspected pulmonary
embolism.
Author Disclosures:
M. Krix: Employee; 2 Bracco Imaging, Global Medical & Regulatory Affairs,
Konstanz, Germany.
B-0438 15:21
Bone suppressed images improve pulmonary fungal infection detection
in chest radiographs
S. Schalekamp
1, I.A.H. van den Berk2, I.J.C. Hartmann3, M.M. Snoeren1,
A.E. Odink3, S.A.H. Pegge4, L.J. Schijf4, N. Karssemeijer1,
C.M. Schaefer-Prokop4; 1Nijmegen/NL, 2Amsterdam/NL, 3Rotterdam/NL,
4Amersfoort/NL (
[email protected])
Purpose: To assess the effect of bone suppression images (BSI) on observer
performance in detecting pulmonary fungal infections (PFI) on chest
radiographs.
Methods
and Materials: 105 frontal (bedside or PA) chest radiographs (CXR)
of suspects for PFI were collected from four institutions. Presence or absence
of disease was determined by an expert radiologist and a clinical researcher in
consensus, using CT as reference standard. Radiographs could contain single
or multiple sites of infection, and were classified into four categories of subtlety.
BSI were generated by ClearRead BSI 3.2 (Riverain Technologies, Ohio). Five
radiologists and two residents participate d in an observer study. Evaluation
was done on a per lung basis, resulting in 78 diseased lungs and 132 normal
lungs. Observers scored the lungs on a continuous scale (0-100), and marked
the most suspicious lesion, if present. Area under the ROC curve (AUC) served
as performance measure. P-values were calculated using the Dorfman-
Berbaum-Metz method. Sensitivity and speci ficity were calculated considering
only the lungs with a suspiciousness score over 50 to be positive.
Results
AUC without BSI was 0.815, and increased to 0.853 with BSI
(p=0.01). Six of the seven observers increased their performance, four of them
significantly. Sensitivity increased from 49% to 66%. Specificity dropped from
95% to 90%. Significant improvement of performance was seen in the group of
very subtle cases (p < 0.001).
Conclusion
BSI significantly improved detection performance of PFI in chest
radiographs, especially for very subtle abnormalities. BSI improved the
sensitivity of the CXR examination, outwei ghing the smaller loss in specificity.
Author Disclosures:
S. Schalekamp: Research/Grant Support; Riverain Technologies. N.
Karssemeijer: Research/Grant Support; Riverain Technologies. C.M.
Schaefer-Prokop: Advisory Board; Riverain Technologies.
14:00 - 15:30 Board Room B
Musculoskeletal
SS 610b
Inflammatory diseases
Moderators:
F. Becce; Lausanne/CH
F. Kainberger; Vienna/AT
B-0439 14:00
Dynamic contrast-enhanced low-field (0.25T) MRI wrist in rheumatoid
arthritis compared with high-field (3.0 T) MRI
K. Lee, J.F. Griffith, J.H.Y. Leung, D. Wang, L. Shi, L. Tam; Hong Kong/HK
(
[email protected])
Purpose: The volume of enhancing synovial tissue and degree of perfusion by
dynamic contrast-enhanced MRI is helpful in determining response to
treatment. This has not been assessed on low-field MRI. The aim of this study
is to compare assessment of wrist synovitis severity, enhancing synovial
volume and synovial perfusion indices of low-field (0.25T) MRI in patients with
rheumatoid arthritis with high-field (3.0 T) MRI.
Methods
and Materials: Prospective study of 21 patients (F:M = 16:5, mean
age 50.0 ± 9.8 years) with active rheumatoid arthritis. Dynamic contrast-
enhanced MRI examination of the most severely affected wrist was performed
on both 0.25T (G-SCAN, Esaote, Italy) and 3.0 T (Achieva TX-series, Philips
Medical Systems, Best, Netherlands) whole-body imaging systems. Three MRI
parameters [synovitis severity (RAMRIS grade), active synovitis volume (ml
3),
and synovial perfusion indices (maximum enhancement (%,) enhancement
slope (%/sec))] were compared.
Results
Comparing 0.25T and 3.0 T MRI, there was excellent agreement for
semi-quantitative assessment (r:0.97, p < 0.00001) and quantitative
assessment (r:0.94, p < 0.00001) of enhancing synovial volume. Good
agreement of Emax (r:0.6, p= 0.002) and fair agreement (r:0.5, p=0.02) for
Eslope were identified.
Conclusion
0.25T MRI yields excellent synovial volume assessment and fair
to good perfusion parameters to 3 T MRI and can be used to assess
therapeutic response in rheumatoid arthritis patients.
S230
BA C D E F G
Friday
B-0440 14:09
Unenhanced and dynamic contrast enhanced (DCE) MRI in assessment
of scaphoid fracture non-union revisited: role in pre-operative planning
S. Janardhan, S. Withey, S. Tan, S. Choudhary; Birmingham/UK
(
[email protected])
Purpose: Accurate pre-operative assessment of proximal pole vascularity aids
in appropriate surgical planning for treatment of non union of scaphoid
fractures. Our study aims to evaluate the usefulness of DCE-MRI in pre-
operative assessment and surgical planning in treatment of scaphoid non-
union.
Methods
and Materials: A retrospective study between Jan 08-May 13
identified 20 patients who underwent pre-operative dynamic Gadolinium-
enhanced wrist MRI on 3 T. Time interval between initial injury and MRI study
was recorded. Using Siemens Mean curve software, a contrast enhancement
curve was generated on dynamic contrast enhanced T1 images with regions of
interest defined in the proximal, distal scaphoid poles and radial styloid. The
steepest upslope of gadolinium enhancement curve was assessed to
determine the degree of vascularity. Results were graded as normal, impaired
vascularity and avascular necrosis (AVN). Unenhanced T1 signal of proximal
pole and subjective assessment of its enhancement pattern were also
analysed. Intra-operative findings were used as gold standard.
Results
14/20 (70%) scans corresponded to intra-operative findings of the
proximal pole vascularity. 5/20 (25%) had discordant results of which 4/5 cases
had time interval of > 7 months between injury and scans. 1/20 had no intra-
operative confirmation. Sensitivity, specificity and accuracy of the DCE-MRI
were 64%, 100% and 74% respectively. In 7/20 confirmed AVN cases, fat
signal was demonstrable on unenhanced T1 images making it a non-specific
finding
Conclusion
Dynamic contrast enhanced MRI is a reliable tool for pre-
operative assessment of proximal pole vascularity and surgical planning.
However MRI results may be confounded if the fracture is old ( > 7 months).
B-0441 14:18
Hybrid 18 F-FDG PET-MRI of the hand in rheumathoid arthritis
F. Miese1, H. Hautzel1, H. Herzog2, B. Ostendorf1, P. Sewerin1, C. Schleich1,
C. Buchbender1, A. Scherer3, G. Antoch1; 1Düsseldorf/DE, 2Jülich/DE,
3Aachen/DE (
[email protected])
Purpose: 18 F-FDG-PET is highly sensitive to inflammatory activity in
rheumatoid arthritis (RA). However, MRI is most sensitive of joint damage in
RA due to its high soft tissue contrast. The purpose of the present study was to
test the feasibility of true hybrid PET-MRI of the hand in RA and to compare
the assessment of synovitis in PET and MRI.
Methods
and Materials: True hybrid 18 F-FDG PET-MRI was acquired in four
patients (all female; average age: 48 years, range 24-58). Two presented with
early therapy-naive RA, two presented prior to therapy escalation. PET-MRI
were acquired on a APD-based magnetoinsensitive BrainPET Detector
(Siemens, Erlangen, Germany) in a 3 T MRI scanner (Magnetom Trio,
Siemens). The MRI data were evaluated according to the RAMRIS synovitis
criteria. The PET of the same joints was categorised semiquatitatively.
Additional findings, not included in the RAMRIS were recorded.
Results
All patients were positive for synovitis in MRI and PET. On a joint
level, 21/26 (81%) of joints were MRI-positive, and 18/26 (69%) were positive
on PET. In three joints that demonstrated synovitis on MRI, glucosis utilisation
was normal (14%). Synovitis severity as measured in PET and MRI correlated
significantly (r = 0.672; P < 0.001). In 6/10 additional abnormal findings, there
was concordance between MRI and PET.
Conclusion
The results point towards the validity of 18 F-FDG PET-MRI of
the hand in RA. 18 F-FDG PET-MRI may possibly be a tool for further research
and therapy monitoring of both, inflammatory activity as well as joint
destruction in RA.
Author Disclosures:
G. Antoch: Speaker; Siemens Medical Solutions, Bayer Healthcare, BTG.
B-0442 14:27
Biochemical MRI with glycosaminoglycan chemical exchange saturation
transfer imaging of finger joint cartilage in rheumatoid arthritis
F. Miese, C. Schleich, A. Müller-Lutz, H.-J. Wittsack, B. Ostendorf, P. Sewerin,
M.J. Schneider, G. Antoch; Düsseldorf/DE (
[email protected])
Purpose: Rheumathoid arthritis (RA) frequently involves finger joint. gagCEST
has been demonstrated to visualise biochemical alterations of cartilage in knee
joints following cartilage repair surgery as well as in intervertebral discs. The
purpose of our study was to test the feasibility of gagCEST in finger cartilage in
healthy volunteers and patients with RA.
Methods
and Materials: Six volunteers (mean age 33; range: 21-45 years)
and four patients (age 58; range: 52-64 years) were examined at a 3 T MR
scanner. For gagCEST imaging, CEST effects were prepared by a train of
Gaussian RF pulses followed by signal readout with a 3D RF spoiled GRE
sequence. The CEST curves were calculated for each pixel and were shifted
for the water resonance to appear at 0 ppm of the Z-Spectrum. The MTR
asymmetry curves were determined. The CEST effect of the cartilage was
measured with the glycosaminoglycan saturation transfer [ST = CEST
(+1.3 ppm) - CEST (-1.3 ppm)/CEST (+1.3 ppm)]. Joint space width (JSW) was
measured.
Results
Cartilage ST values were significantly lower in patients compared to
healthy volunteers (13.58 ± 6.11 vs. 27.38 ± 4.52; p=0.011). CEST curves
showed a decrease between 1.2 and 2.2 ppm, corresponding to the resonance
frequency of hydroxyl protons of glycosaminoglycans. There was no significant
difference in JSW.
Conclusion
CEST imaging revealed alterations in finger cartilage of RA
patients compared to healthy controls in the absence of cartilage thinning. The
decreased CEST effect in the spectral range of glycosaminoglycan resonances
points towards depletion of glycosaminoglycans in RA.
Author Disclosures:
G. Antoch: Speaker; Siemens Medical Solutions, Bayer Healthcare, BTG.
B-0443 14:36
Characterisation of metacarpal and radial bone in rheumatoid arthritis
using high-resolution peripheral quantitative CT
H. Yang, A. Yu, A. Burghardt, T. Link, X. Li; San Francisco, CA/US
(
[email protected])
Purpose: 1) To develop a standardised method of quantifying BMD and
microarchitecture in the hand and wrist bones of patients with rheumatoid
arthritis (RA) using HR-pQCT; 2) to compare quantified bone parameters of
controls to those of RA and post-menopausal osteopenic (PM-OP) subjects,
and 3) to correlate quantified bone parameters at the distal radius and
metacarpal heads of RA subjects.
Methods
and Materials: HR-pQCT imaging of the dominant hand and wrist
was performed in 12 female RA patients and 20 healthy female controls. BMD
and trabecular parameters for the 2-12% head region of the metacarpals were
calculated and compared between RA and controls. Bone parameters were
also calculated for the distal radius in RA patients and compared to data from
controls and 44 PM-OP women. Clinical evaluations of RA patients were
examined for correlation to bone parameters.
Results
Compared to controls, RA patients had significantly decreased BMD,
trabecular volume and number, and increased trabecular heterogeneity.There
were no significant differences in the bone parameters between RA patients
and PM-OP women, except trabecular number. Trabecular BMD in the third
metacarpal and in the distal radius were significantly correlated ( ;=0.918,
p < 0.0001) in RA patients.
Conclusion
This study established a standardised method for quantifying
bone density and trabecular properties in the hand and wrist bones of RA
patients using HR-pQCT. Deterioration of bone structure in RA patients was
found comparable to that in osteopenic women, and trabecular bone loss near
affected joints was found to be correlated with bone loss away from joints.
B-0444 14:45
Ultrasound findings in hand joints involvement in patients with psoriatic
arthritis and its correlation with clinical DAS 28 score
P.M. Naranje, M. Prakash, A. Sharma, S. Dogra, N. Khandelwal;
Chandigarh/IN (
[email protected])
Purpose: To evaluate the ultrasound findings in hand joints in patients with
psoriatic arthritis and correlate grayscale and power Doppler ultrasonography
findings with Disease Activity Score 28.
Methods
and Materials: This prospective study was performed in 30 patients.
Ultrasound evaluation of 28 joints of both hands was undertaken and findings
were recorded including synovial hypertrophy, power Doppler abnormality, soft
tissue thickening, tendonitis, joint effusion, periosteal reaction and erosions.
Composite ultrasound scores and Diseas e Activity Score 28 were calculated
and compared.
Results
Ultrasound detected more abnormalities in the hand joints than did
clinical examination. The frequency of ultrasound abnormalities:Synovial
hypertrophy in 100%, power Doppler abnormality suggesting hypervascularity
in 36.7%,soft tissue thickening in 66.7 %,periosteal reaction in 33.3%,erosions
in 30% (mostly in DIP and PIP joints) and flexor tendonitis in 6.7% of patients.
Significant correlation was found between Disease activity score 28 and gray-
scale joint score (GSJS) (Spearman's ;: 0.499, P: 0.005),gray-scale joint count
(GSJC)(;: 0.398, P: 0.029) and power Doppler joint score (PDJS) ( ;:0.367,
P:0.046). There was a statistically signif icant difference between remission and
low disease activity group, and moderate disease activity group in terms of
GSJC, GSJS, PDJC and PDJS (P < 0.05). These ultrasound measures were
higher in moderate disease activity zone patients.
S231
BA C D E F G
Friday
Conclusion
Ultrasound is a useful modality for the objective assessment of
psoriatic arthritis, which can detect joint inflammation to a larger extent than
clinically expected. Ultrasound including power Doppler can be used as a
modality for assessment of severity of psoriatic arthritis as it correlates with the
clinical scoring.
B-0445 14:54
Role of MRI in evaluation of asymmetric undifferentiated inflammatory
hand arthritis: can it help change the diagnosis?
R.K. Paruchuri, L. Rajashekhar; Hyderabad/IN (
[email protected])
Purpose: The ACR/EULAR 2010 criteria is a cl inical tool that aids the clinician
in identifying patients of undifferentiated arthritis who require early aggressive
therapy. MRI can increase its sensitivity by identifying patients with disease
more progressed than thought of clinically thus altering the treatment.
Methods
and Materials: MRI was performed for 25 patients with ACR/EULAR
score of 6/10. Bilateral wrists, metacarpophalangeal and proximal
interphalageal joints were evaluated for evidence of bone erosions, bone
oedema, synovitis, tenosynovitis and effusions. Presence of synovitis and
erosions or oedema was categorised as rheumatoid arthritis (RA) while
absence of synovitis but presence of other findings was categorised as
probable RA.
Results
The female to male ratio was 3:1 and average age was 43 years.
Based on the MRI findings, a diagnosis of RA was given in 12 cases (48%)
and probable RA in 7 cases (28%) giving a total of 19 cases (76%). 5 patients
were still labeled as undifferentiated arthritis (20%) and 1 as post viral
sequelae. Bone erosions were the commonest finding in these 19 patients,
seen in 18 (94%)cases, followed by effusions 78%, synovitis (63%),
tenosynovitis (52%) and bone oedema (47%).
Conclusion
Studies have shown that a significant number of patients
presenting with undifferentiated arthritis will progress to RA and early
therapeutic intervention delays or halts the disease. We successfully identified
patients with more advanced disease than clinically thought of. Thus, the
addition of MR imaging-based joint area involvement (clinically normal) may
enhance the performance of the ACR/EULAR 2010 RA criteria.
B-0446 15:03
Assessment of radiographic progression in rheumatoid arthritis patients
using Sharp/van der Heijde scoring method: comparison with plain
radiography and tomosynthesis
M. Fujii, T. Aoki, S. Kinoshita, H. Oki, Y. Hayashida, K. Saito, Y. Tanaka,
Y. Korogi; Kitakyushu/JP
Purpose: Sharp/van der Heijde scoring method is commonly used for the
evaluation of radiographic progression in adult rheumatoid arthritis (RA)
patients. The purpose of this study is to compare tomosynthesis with plain
radiography of the wrist and hand for the applicability of radiographic
progression assessment using Sharp/van der Heijde scoring method.
Methods
and Materials: Twenty consecutive patients with established
diagnosis of RA were included in this study. Plain radiography and
tomosynthesis of the bilateral hand and wrist were undergone within a week at
both baseline and follow-up. The mean total dose of radiography and
tomosynthesis was 0.13 mGy and 0.25 mGy, respectively. Sharp/van der
Heijde score on images from the 2 modalities was independently reviewed by 2
radiologists (23 and 6 years of experience in interpreting musculoskeletal
radiography). Interobserver agreement for the Sharp/van der Heijde scores
was analysed by computing the intraclass correlation coefficient (ICC). The
reading time per case for each modality was also recorded.
Results
Significantly higher Sharp/van der Heijde scores were revealed with
tomosynthesis than with plain radiography (P <.01). Interobserver agreement
on baseline Sharp/van der Heijde scores were excellent for both plain
radiography and tomosynthesis (ICC=0.95, 0.98 respectively). Agreement on
change assessment was excellent for tomosynthesis (ICC=0.93) but moderate
for plain radiography (ICC=0.71). The reading time with tomosynthesis was not
significantly different from plain radiography.
Conclusion
Tomosynthesis is more reliable for Sharp/van der Heijde scoring
Method
in RA patients than radiography, and may be suitable for the reference
method.
B-0447 15:12
Ultrasonographic diagnosis in rheumatoid arthritis: should only
symptomatic joints be scanned?
Y. Volokhina, S. Beck, A. Chien; Loma Linda, CA/US (
[email protected])
Purpose: To investigate the validity of reduced joint counts for
ultrasonographic (US) assessment of joint inflammatory activity by scanning
only symptomatic joints in patients with known or suspected rheumatoid
arthritis (RA).
Methods
and Materials: 129 patients seen in rheumatology clinic received US
scans of bilateral hands. Clinical symptoms (joint pain, swelling, warmth) and
US findings (synovial hypertrophy, hyperaemia, erosions) were recorded in the
scanned joints of bilateral wrists, first th rough fifth metacarpophalangeal and all
interphalangeal joints. Assuming two different levels of disease activity of US
findings, hyperaemia > synovial hypertrophy >erosions (H >SH>E) vs.
hyperaemia>erosions>synovial hypertrophy (H >E>SH), each patient was
analysed for correlation of US and clinical findings.
Results
36 patients had known diagnosis of RA, and 83 patients had
questionable diagnosis of RA. Out of 36 patients with known RA, scanning only
symptomatic joints while assuming the H >SH>E level of disease activity, 9
patients with positive US findings w ould have been underreported (75%
sensitivity), while 11 patients with positive US findings would have been
underreported (69% sensitivity) if the accepted level of disease activity were
H>E>SH. Out of 83 patients with questionabl e diagnosis of RA, scanning only
symptomatic joints while assuming the H >SH>E level of disease activity, 28
patients with positive US findings w ould have been underreported (66%
sensitivity), while 29 patients with positive US findings would have been
underreported (65% sensitivity) if the accepted level of disease activity were
H>E>SH.
Conclusion
Scanning only symptomatic joints in patients with both known and
suspected diagnosis of RA would underreport the disease activity.
B-0448 15:21
Computer-aided and manual quantifications of MRI synovitis, bone
marrow oedema, erosion and cartilage loss in rheumatoid arthritis
H. Yang, J. Rivoire, M. Hoppe, T. Link, X. Li; San Francisco, CA/US
(
[email protected])
Purpose: To investigate the reliability and validity of multiple computer-aided
and manual quantifications and semi-qua ntifications for MRI synovitis, bone
marrow oedema, erosion and cartilage loss of wrist in rheumatoid arthritis (RA).
Methods
and Materials: Wrist MRI was performed at 3 T in 16 RA patients
and 3 controls. Synovitis volume and perfusion, bone marrow oedema (BME)
volume, signal intensity and perfusion , and erosion dimension were measured
by in-house developed software, and correlated with OMERAC-RAMRIS. A
semi-quantitative MRI cartilage loss score system was developed. Intra-class
correlation coefficients (ICCs) were used to test reproducibility of these
quantifications and semi- quantifications. Spearman correlation coefficients
were calculated between lesion quantifications and RAMRIS, and between
MRI cartilage score and radiographic Sharp score.
Results
The intra- and inter-observer ICCs were excellent for synovitis, BME
and erosion quantifications and cartilage loss grading (all > 0.89). The synovitis
volume, BME volume and signal in tensity, and erosion dimension were
significantly correlated with corresponding RAMRIS (r = 0.727 to 0.900,
p < 0.05). Synovitis perfusion parameter maximum enhancement (E) was
significantly correlated with synovitis RAMRIS (r = 0.798), but steepest slope
(S) was not. BME perfusion E and S were not correlated with RAMRIS.
Cartilage loss grading was significantly correlated with the Sharp joint space
narrowing score (r = 0.635, p = 0.008).
Conclusion
Multiple computer-aided and manual and semi-quantitative
Methods
can be used to evaluate MRI pathologies in RA with excellent
reproducibility. Quantitative evaluation can be more sensitive for detecting
disease activity or subtle changes duri ng follow-up than conventional scoring
system.
B-0449 15:30
Biochemical cartilage MRI and synovitis severity in rheumatoid arthrits:
correlation of cartilage damage and inflammatory activity
F. Miese, C. Schleich, C. Buchbender, C. Nowak, P. Kröpil, B. Ostendorf,
R. Lanzman, H.-J. Wittsack, G. Antoch; Düsseldorf/DE (
[email protected])
Purpose: To test for a correlation between cartilage composition and
inflammatory activity on an individual joint level in early, therapy-naïve
rheumatoid arthritis (RA).
Methods
and Materials: Metacaropophalangeal joints in 27 patients with RA
were examined (22 females, five males, mean age 54 years). Delayed Gd-
enhanced MRI of the cartilage (dGEMRIC) of MCP joints was acquired on a
3 T scanner. dGEMRIC index was determined as measure of cartilage
glycosaminoglycan content. Inflammatory activity was assessed using the
synovitis-subscore according to the RAMRIS-criteria on coronal T1-weighted
images acquired prior to and following Gd-administration and on post-contrast
axial T1-weighted images with fat suppression.
Results
Synovitis severity was 0 in three cases, grade 1 in six cases, grade 2
in eight cases and grade 3 in ten cases. Average dGEMRIC index was
408 ms ± 145 ms. There was a significant correlation between dGEMRIC index
and synovitis severity (Spearman rho= -0.49; p = 0.009).
Conclusion
Decreased glycosaminoglycan content was significantly
associated with inflammatory activity in i ndividual metacarpophalangeal joints
in early, therapy-naïve RA. The correlation was only moderately close
suggesting concurrent cartilage damaging factors.
Author Disclosures:
G. Antoch: Speaker; Siemens Medical Solutions, Bayer Healthcare, BTG.
S232
BA C D E F G
Friday
14:00 - 15:30 Room E1
Musculoskeletal
SS 610a
Spine
Moderators:
E.J. Ulbrich; Zurich/CH
F.M.H.M. Vanhoenacker; Antwerp/BE
B-0450 14:00
Lumbar spine MRI findings predicting instability: a comparative study
using flexion-extension radiography
J.P.M. Vrouwe
1, G.K. Thawait1, M. Reijnierse2, D.B. Cohen1, L.H. Riley1,
K.M. Kebaish1, U. Thakur1, R. Rao1, J.A. Carrino1; 1Baltimore, MD/US,
2Leiden/NL (
[email protected])
Purpose: Lumbar spine MRI is performed in supine position and interpretation
often occurs without radiographic comparison. The purpose of this study was
to identify lumbar spine MRI predictors for radiographic instability.
Methods
and Materials: Institutional review board approval was obtained for
this retrospective study. 970 lumbar sp ine levels of 194 patients [mean age
58.8; range 19-87; 109 (56.1%) female] were reviewed in flexion-extension
radiographs as well as T1,T2 and STIR weighted MRI. Excluded were patients
with a history of spinal problems. MRIs were assessed for the qualitative
presence of high intensity zone (HIZ), Modic change and facet joint bone
marrow oedema (BME); disc degeneration, facet joint osteoarthritis (FJOA),
disc contour appearance, muscular atrophy (MA) and central stenosis (CS)
were rated semi-quantitatively. Quantitative data were collected for facet joint
effusion/widening (FJE), facet angles (FA) and interfacet distance (IFD). Data
were analysed by odds ratio calculation and using 2-sided independent t-test.
Results
Of the 970 levels, 177 (18.2%) levels had radiographic evidence of
instability; these cases were female in 59.3%(105/177), controls in
55.5%(440/793). MRI showed 120 levels of listhesis. Odds ratios were
calculated for: HIZ-1.32 (0.91-1.93) p=0.143; Modic change-2.39 (1.71-3.32)
p <.01; and BME-2.61 (1.62-4.20), p < 0.01. Comparison of the semi-
quantitative findings showed higher degrees of disc degeneration (p < 0.01),
FJOA (p=0.001), abnormality in disc contours (p=0.001), MA (p < 0.001), and
CS (p <.001) in cases than in controls. Processing of numeric ratings showed a
mean FJE of 1.76 mm in cases and 1.29 mm in controls (p=0.001); mean FA
was 55° and 54°, respectively (p=0.68); mean IFD was 3.56 cm and 3.42 cm,
respectively (p=0.14).
Conclusion
Several degenerative changes on MRI are more frequently
present with radiographic instability.
B-0451 14:09
A clinical epidemiological imaging study of spinal segment variants in a
non-symptomatic population
J.P.M. Vrouwe1, G.K. Thawait1, M. Haider1, S.K. Thawait1, A. Chhabra2,
J.A. Carrino1; 1Baltimore, MD/US, 2Dallas, TX/US
(
[email protected])
Purpose: Spinal variances may lead to confusion and inaccurate numbering of
the vertebral segments. The purpose of this abstract is to determine the
prevalence of spinal segmental variants in an asymptomatic population.
Methods
and Materials: Institutional review board approval was obtained for
this retrospective study. Review of whole body isotropic Computed tomography
(CT) of 450 patients (males 171; mean age 31, age range17-45) without back
pain was performed. Vertebral numbering was performed and the presence of
cervical ribs, thoracolumbar transitional vertebra (TLTV); and lumbosacral
transitional vertebra (LSTV) was documented. Cervical ribs and variances were
noted. TLTVs were defined as presence of hypoplastic ribs (HR) or non-fused
transverse apophyses (NFA) at the level of lowest rib-bearing segment. LSTVs
were characterised as per Castellvi.
Results
450 cases were reviewed and the number of presacral segments was
accounted for as: 22 in 0.2%(1/450), 23 in 1.8%(8/450), 24 in 93.3%(420/450)
and 25 in 4.7%(21/450). Presence of cervical ribs was seen in 4.2%(19/450)
and elongated C7 transverse process in 2.7%(12/450) of the study population.
TLTV was found in 23.3%(105/450) with HR in 9.6%(43/450) and NFA in
13.8%(62/450). LSTV was noted in 26.4%(119/450) of the population and they
were classified based on Castellvi's classification as: Type Ia in 3.8%(17/450),
Type Ib in 2.2%(10/450), Type IIa in 6.9%(31/450), Type IIb in 6.4%(29/450),
Type IIIa in 1.1%(5/450), Type IIIb in 3.8%(17/450) and Type IV in
2.2%(10/450).
Conclusion
This study provides a clinical epidemiological approximation for
prevalence of spinal segmental variability and highlights the large variability of
segmental anatomy relevant to spine imagers and clinicians.
B-0453 14:27
The effect of active referral guideline implementation on the number and
justification of spine radiographs in municipal health centres in one city
P. Tahvonen, H. Oikarinen, J. Niinimäki, O. Tervonen; Oulu/FI
(
[email protected])
Purpose: To determine the effects of active implementation of referral
guidelines on the number and justification of spine radiographs requested by
practitioners in municipal health centres in one city.
Methods
and Materials: Specified guidelines for spine radiographs were
distributed, first time with an educational cover letter, by e-mail to referring
practitioners and the staff of the radiology department altogether three times
during the study period. Educational lectures were also provided. The number
of spine radiographs (patients aged 16 years) during similar 6-month periods
in the year preceding the interventions and the following 2 years was analysed.
Furthermore, justification of 450 different spine radiographs performed during
these years was assessed by using requests and corresponding patient files.
Difference between the total numbers of examinations was calculated using
²goodness of fit test and changes in proportions of justified cases using
independent samples ²test.
Results
After interventions, the total number of spine radiographs decreased
by 48% (9.53/1000 citizens vs. 4.98/1000, p < 0.001) and that of the cervical
spine by 46%(2.29/1000 vs. 1.23/1000, p < 0.001), thoracic spine by 53%
(1.22/1000 vs. 0.58/1000,p < 0.001) and lumbar spine by 47% (6.02/1000 vs.
3.18/1000, p < 0.001). The results persisted after 1-year follow-up. Before
interventions, 24% (12/50) of the cervical, 46% (23/50) of the thoracic and 32%
(16/50) of the lumbar spine radiographs were justified. After interventions only
justification of the lumbar spine radiogr aphs improved significantly, 64% being
justified (p=0.005).
Conclusion
The number of spine radiographs decreased significantly. The
level of justification was low and only justification of the lumbar spine
radiographs improved significantly.
B-0454 14:36
Signal intensity of the cervical spine
F. de Bruin1, S. ter Horst1, H. Bloem1, K. Fagerli2, R. Landewé3,
M. van Oosterhout4, D. van der Heijde1, M. Reijnierse1; 1Leiden/NL, 2Oslo/NO,
3Amsterdam/NL, 4Gouda/NL (
[email protected])
Purpose: Disc degeneration in the cervical spine has not been described so
far. No classification system for the cervical spine exists. Therefore, we applied
the Pfirrmann classification to the cervical spine.
Methods
and Materials: Patients (n = 260) from the SPondyloArthritis Caught
Early (SPACE) cohort were included with back pain 3 months, 2 years,
onset < 45 years. Cervical T1 and STIR MR sagittal images were scored on the
Pfirrmann classification sc ale by two readers, a third acted as adjudicator. The
Pfirrmann classification describes degener ative changes of intervertebral discs
in the lumbar spine on a 5-points scale: class 1 normal, class 5 collapsed disc
space.
Results
1300 intervertebral discs were scored (C2-C3 though C6-C7). 499
(38%) discs had a Pfirrmann score of 1, 664 (51%) discs were scored as class
2, 128 (10%) discs were scored as class 3, 8 (1%) as class 4 and 1 (0%) as
class 5. Frequencies of class 2 and up were highest on levels C2-C3 and C3-
C4, 168 (65%) and 178 (68%). In 126 (48%) patients, the first 4 intervertebral
discs were scored as class 2 or higher.
Conclusion
Over half of all cervical discs were inhomogeneous without loss
of height (Pfirrmann 2), 11% of discs were grey to black and had loss of height
to some degree (Pfirrmann 3 or higher). The upper levels of the cervical spine
were most frequently affected. The Pfirrmann class of the cervical spine
appears higher than the lumbar spine and might be a normal variant.
B-0455 14:45
Determinants of evolution of endplate and disc degeneration in the
lumbar spine: a multifactorial perspective
N. Farshad-Amacker, A. Hughes, A. Aichmair, R.J. Herzog, M. Farshad;
New York, NY/US (
[email protected])
Purpose: Radiographic progression of disc and endplate degeneration of the
lumbar spine is thought to be multifactorial. The aim of this study was to find
the strength of influence and interaction of the factors and their interaction in
order to understand which are the most important determinants in evolution or
progression of lumbar spinal degeneration.
Methods
and Materials: Patients (n=90) who underwent two lumbar MRI
exams with an interval of at least four years and without any spinal surgery
where retrospectively included. Disc degeneration was scored according to the
Pfirrmann classification and endplate chan ges according to Modic in 450 levels
on both MRIs. Potential variables for degeneration such as age, gender, BMI,
scoliosis and sagittal parameters were compared between patients with and
without evolution or progression of degenerative changes in their lumbar spine.
S233
BA C D E F G
Friday
A multivariate analysis aimed to separate the most important variables for
progression of disc and endplate degeneration, respectively.
Results
While neither age, gender, BMI, sacral slope or presence of scoliosis
could be identified as progression factor for disc degeneration, a higher
lordosis was observed in subjects with no progression (49.2 ±11.0 vs
43.2±11.7,p=0.017). Progression or evolution of endplate degeneration was
only associated with higher degree of scoliosis (9.5 ±10.4 versus 5.9 ±9.0;
p=0.0078) and not to any of the other variables.
Conclusion
While a scoliotic deformity of the lumbar spine is associated with
evolution or progression of endplate degeneration, a higher lumbar lordosis
seems protective for radiographic progression of disc degeneration.
B-0456 14:54
Comparison of lumbar disk height measurements between EOS system
and digital radiography
V. Freire, A. Feydy, M. Benhamou, S. Poiraudeau, J.-L. Drapé; Paris/FR
(
[email protected])
Purpose: Biplane slot scanning systems are used by clinicians in daily
practice, based on two low-dose simultaneous digital anteroposterior and
lateral radiographs, avoiding the magnification presented in digital radiography
(DR) images. The aim of this study was to compare lumbar disk height (LDH)
between a biplane slot scanning system (i.e. EOS system) and a DR system,
showing that biplane slot scanning systems provide more accurate
measurements.
Methods
and Materials: (a) In-vivo: 50 patients [41 women, 9 men, age: mean
(SD): 49.4 (10.7)] presenting chronic low back pain were included. Lateral
radiographs of the spine were obtained with the EOS system and a DR
system. Two senior clinicians measured the LDH between L3-L4, L4-L5 and
L5-S1. Mean (SD) of the measurements, reproducibility (ICC coefficient)
between both readers, as well as image quality (from 0 to 10) were calculated.
(b) In-vitro: we used a phantom apparatus to perform five vertical
displacements of 2 mm on two dry vertebrae. LDH was measured for each
displacement with EOS and DR.
Results
(a) In-vivo: Image quality was equivalent for both systems, as well as
reproducibility. LDH measured (in mm) by DR was systematically higher as
compared to EOS system [Reader 1- EOS:7.3 (1.9), DR: 8.9 (2.6), Reader 2 -
EOS:7.3 (1.5), DR: 10.1 (1.9)]. (b) In-vitro: Mean (SD) differences between true
and measured LDH for EOS [0.4 (1.1) mm], and DR [2.1 (1.4) mm] were
statistically significant (Student's t test p < 0.05).
Conclusion
Biplane slot scanning systems provide reliable measurements of
the LDH while reducing the radiation dose.
B-0458 15:03
Association of low-back pain with modic type endplate changes and disc
degeneration using a detailed MRI-classification
K. Luoma, L. Kerttula, T. Vehmas, M. Grönblad; Helsinki/FI
(
[email protected])
Purpose: Modic type 1 signal abnormality in bone marrow (M1) may have
impact on treatment decisions for low-back pain (LBP) patients. M1 is
associated with rapidly progressing bony endplate lesions (EPL) and disc
degeneration (DD). The association of LBP with M1s, EPLs and DD was
studied with a more detailed grading method than conventional Pfirrman and
Modic classification.
Methods
and Materials: 49 patients with chronic nonspecific LBP and large
M1 had a follow-up MRI (1.0 T) after one year. Severity of LBP (VAS) on
numerical scale 0-10 and of disability (ODI) on scale 0-100 was questioned
and size of M1, severity of adjacent EPLs and of DD was visually classified in
consensus at baseline and follow-up. Change in VAS and ODI was non-
parametrically correlated with change in M1 size and grade of EPLs and DD
separately (Pearson correlation, 2-tailed).
Results
Increase of pain (VAS) correlated with increase of M1 (p < 0.01) and
of EPLs (p=0.02) and with increase of signal intensity of nucleus pulposus
(DSI) in discs with decreased height (p=0.01). ODI correlated with increase of
DSI (p=0.03) and with increase of M1 (p=0.07).
Conclusion
In addition to signal abnormalities in subchondral bone marrow,
defects and irregularities in endplate region and increase of signal intensity in
nucleus pulposus may be at least as important as conventionally classified
Modic changes and degenerative disc cha nges in explaining nonspecific LBP.
Detailed classifying separate changes in subchondral bone marrow, disc and
endplate may promote MRI-diagnosti cs of the pathologic, progressive
degenerative disc disease.
B-0459
15:12
Image quality optimisation of spinal exams with metal artifacts using
iterative reconstruction in combination with monoenergetic extrapolation
H. Haubenreisser1, M. Hahn1, J.W. Nance2, P. Apfaltrer1, M. Sedlmair3,
B. Schmidt3, S.O. Schönberg1, T. Henzler1; 1Mannheim/DE, 2Baltimore,
MD/US, 3Forchheim/DE (
[email protected])
Purpose: To evaluate the effectiveness of spectral CT in combination with
iterative reconstruction (IR) in the raw data space in reducing metal artifacts
caused by pedicle-screws in patients with dorsal spinal fusion.
Methods
and Materials: 10 consecutive patients with dorsal spinal fusion with
a total of 57 pedicle-screws referred for dual-energy CT (DECT) of the spinal
column were prospectively included in the study. Data was acquired at 80 and
140 kVp. Each DECT dataset was reconstructed with traditional filtered back
projection (FBP) as well as IR, after which monoenergetic image sets ranging
from 60keV to 180keV were generated at 10keV intervals. Both objective
(quantitative artifact and image noise measurements) and subjective
evaluation (diagnostic quality, depicti on of pedicle-screws and surrounding
structures) were performed.
Results
Image quality of monochromatic images in the range from 80 keV to
120keV was rated superior to both the conventional polychromatic images as
well as the monochromatic sets at lower energies. In addition, even though IR
had no significant impact on the presence of artifacts (p=0.841-0.998), both
Objective
(p < 0.001) and subjective (p < 0.001) image quality parameters of
sets reconstructed with IR were consistently better than the FBP sets.
Interobserver agreement was good to excellent (Cohen's K=0.74).
Conclusion
Compared to conventional polychromatic images, monochromatic
images acquired from DECT provided superior image quality with reduced
metal artifacts in patients with spinal fusion. Optimal energy range was at
around 110 keV. IR was found to further improve both subjective and objective
image quality, especially of the surrounding tissue.
Author Disclosures:
M. Sedlmair: Employee; Siemens Medical Solutions. B. Schmidt: Employee;
Siemens Medical Solutions.
14:00 - 15:30 Room F2
Breast
SS 602
Beyond B-mode ultrasound
Moderators:
G. Forrai; Budapest/HU
A. Linda; Udine/IT
B-0461 14:00
Evaluation of breast lesions with a spiculation and retraction severity
index (SRSI) on coronal reconstructions of automated breast ultrasound
improves differentiation between benign and malignant lesions
J.C.M. van Zelst
1, B. Platel1, M. de Jong2, T. Tan1, M. Rutten2, R.M. Mann1,
N. Karssemeijer1; 1Nijmegen/NL, 2's-Hertogenbosch/NL
(
[email protected])
Purpose: To investigate the value of a spiculation and retraction severity index
(SRSI) in coronal reconstructions of ABUS to improve the differentiation
between benign and malignant breast lesions.
Methods
and Materials: 96 ABUS scans from 96 patients were obtained. All
scans contained a biopsy-proven lesion (36 malignant, 60 benign). Each scan
was presented to 5 breast radiologists (ABUS experience 0-3 years). First, only
the transversal acquisition was shown. Readers were asked to classify the
most suspicious lesion in the scan using the BI-RADS lexicon. A likelihood-of-
malignancy (LOM) score (0-10.0) was requested. Thereafter, the coronal
reconstruction was shown. Readers were asked to rate spiculation and
retraction in the coronal plane on the SRSI, a 5-point semi-continuous index.
Subsequently, LOM-scores could be adjusted. The differentiating capacity of
SRSI between benign and malignant lesions was assessed using ROC-
analysis. Reader agreement for SRSI was computed with the intraclass
correlation coefficient (ICC). AUCs based on LOM-scores prior to and after
evaluation of the coronal scans were calculated using multi-reader-multi-case
ROC-analysis.
Results
The SRSI is highly discriminative between benign and malignant
lesions with AUCs ranging from 0.796-0.883. The ICC shows substantial
agreement between readers in assessing SRSI (0.605, p < 0.001). All readers
improved their performance after evaluation of the SRSI with an overall
increase in AUC from 0.82 to 0.87 (p=0.01). Moreover, readers downgraded
3%-18% benign cases to BI-RADS 2 avoiding unnecessary biopsies.
S234
BA C D E F G
Friday
Conclusion
Evaluating spiculation and retraction patterns on coronal
reconstructions of ABUS using SRSI, improves radiologists' performance in the
differentiation between malignant and b enign breast lesions significantly.
B-0462 14:09
The impact of real-time virtual sonography in the surgical management of
breast cancer: a single-institution review
M. Yoshida, S. Nakano, K. Fujii, J. Kousaka, Y. Shiomi, R. Tetsuka, T. Andou,
T. Imai, T. Fukutomi; Aichi/JP (
[email protected])
Purpose: Real-time virtual sonography (RVS) synchronises ultrasonographic
images and MR images of the same section in real time. The aim of this study
was to evaluate the impact of RVS in the surgical management of breast
cancer.
Methods
and Materials: A total of 108 breast cancer patients were identified
as candidates for breast-conserving surgery (BCS) based on conventional
assessments and underwent a preoperative breast MRI. When the additional
lesion was detected by MRI, it was preoperatively assessed by second-look
ultrasonography (US) and, if needed, US-guided needle biopsy. If the
additional MRI lesion was undetectable by conventional US, we performed a
second-look US assessment with the use of RVS.
Results
In 46 out of the 108 affected breasts, 49 additional ipsilateral MRI
lesions were detected. The detection rate of the additional MRI lesions by
conventional second-look US was 45%, while the rate went up to 92% when
using RVS. In 40 of the 46 breasts, on the basis of second-look US/RVS
assessments, we had increased the extent of resection (BCS with wider
margins 18, Mastectomy 22). As a result, the rate of positive margins after BCS
was 13% and the presence of invasive component on the margin was only 1%.
Conclusion
Our results suggest that the improved detection rate of the
additional MRI lesions by second-look US with RVS can lead to the reduction
of positive margins after BCS.
B-0463 14:18
Predictive value of posterior acoustic features in the biological behaviour
of breast tumours
Y. Fernandez Nuñez, R. Medina, R. Revert Espi; Valencia/ES
(
[email protected])
Purpose: To evaluate the association between the sound-attenuating
properties of breast cancer with tumor grade, hormone receptors expression,
ERRB2 oncogene and ki -67 marker, as well as to assess the predicting value
of these features.
Methods
and Materials: The posterior acoustic properties of 138 breast
cancer ultrasound images obtained between January and December 2012
were reviewed and correlate with tumor grade, estrogen/progesterone receptor
expression, ki-67 and ERRB2 receptor status. These posterior acoustic
features were classified into shadowing, enhancement, mixed pattern and no
change.
Results
Of the 22 CDI with grade III, 77.3 % had posterior enhancement,
while 13.6% had posterior shadowing. There were 23 lesions with negative
estrogen receptors, of which 87.0 % had posterior enhancement and 8.7 %
had posterior shadowing, with statistically significant difference. Also, of the 32
patients with negative progesterone receptors there was observed a higher
proportion of lesions with posterior enhancement (65.6 %) and only 15.6 % had
posterior shadowing. Of the 18 lesions with high expression of ki-67, 72.2%
had posterior enhancement and 11.1% had posterior shadowing. There were
no significant differences between tumor grades I and II and acoustic features,
nor with ERRB2 oncogene.
Conclusion
The presence of posterior enhancement is strongly associated
with a higher tumor grade and higher risk of being estrogen and progesterone
receptor negative as well as greater expression of Ki -67 marker.
B-0464 14:27
Role of targeted-ultrasonography in further assessing incidentally
detected breast lesions at dynamic magnetic resonance imaging
R.O. Stroie, V. Londero, A. Gualano, R. Girometti, C. Zuiani, M. Bazzocchi;
Udine/IT (
[email protected])
Purpose: To investigate the role of targeted-ultrasonography (targeted-US) in
identification and characterisation of inci dental enhancing lesions on breast
dynamic-Magnetic Resonance Imaging (dynamic-MRI).
Methods
and Materials: We retrospectively reviewed 2500 consecutive breast
dynamic-MRI during a 2-year period, identifying 142 incidental enhancing
lesions categorised as 3, 4, 5 on BI-RADS MRI lexicon. Correlations between
MRI lesion characteristics, histopathologic findings and US detection rate were
analysed. The reference standard was histopathologic examiantion after
needle biopsy or surgical excision in 102 of 142 (72%) lesions and follow-up
(24 months) in 40/142 (28%). Statistical analysis used Chi-square test.
Results
US correlation was made in 104/142 (73%) lesions. Higher US
detection rate was observed for masses (84/104 [81%]) rather than non-
masses (12/21 [57%]) (p=0.04), for MRI BI-RADS category 4-5 (51/62 [82%])
rather than category 3 (53/80 [66%]) (p=0.036). Targeted-US equally identified
malignant and benign lesions [46/63 (73%) and 58/79 (73%)]. 8 of the
malignancies were assessed as MRI BI-RADS 3 and 38 as MRI BI-RADS 4-5,
in concordance to the presumed US suspect pattern. Sonographic correlation
was also higher in invasive (39/50 [78%]) compared to non-invasive (7/13
[54%]) malignancies (p=0.15) although an y statistically significant difference.
Sensitivity, specificity, positive and negative predictive values regarding the US
second-look, were respectively, 82%, 69%, 68% and 83%.
Conclusion
Targeted-US identifies most of the incidental enhancing breast
MRI lesions, especially those assessed as masses with a high grade of
suspicion that necessitate further characterisation with US-guided needle
biopsy. The lack of an US correlate does not obviate the need for biopsy.
B-0465 14:36
Can transmission-ultrasound tomography detect small lesions in dense
breasts?
V.Z. Marmarelis; Los Angeles, CA/US (
[email protected])
Purpose: To examine whether the novel 3D diagnostic imaging technology of
transmission-ultrasound tomography (TUT) can detect small lesions ( < 10 mm)
in dense breasts of 112 BI-RADS 4 volunteers (ACR 3 or 4).
Methods
and Materials: The TUT system performs 3D tomography of the
pendulant breast using transmission ultrasound (distinct from conventional
echo-mode ultrasound) in a fixed-coordinate system. Design details were
presented in ECR 2011 and 2012. TUT constructs multiple images for each
coronal slice, using measurements of refractivity and frequency-dependent
attenuation and dispersion, which are combined to form the composite index
(CI) of each tissue voxel. High values of CI index are used for detection and
differentiation of breast malignant lesi ons. Initial results were published in
European Radiology (Feb. 2013). This study is focused on dense breasts of
112 BI-RADS 4 female volunteers (ages 36-78) and examines the CI values of
34 malignant and 78 benign lesions (sizes 2-10 mm, median of 6.2 mm)
confirmed by histopathology of biopsy samples.
Results
The CI values of malignant lesion voxels were above 1.04, which is
the cut-off point in the distribution of CI values of normal breast tissue and
benign lesion voxels, whilst 99.9% of normal tissue voxels had CI values
< 0.56. This allows detection and differentiation of breast lesions with high
statistical significance.
Conclusion
Initial results indicate the potential of TUT to detect and classify
small breast lesions ( < 10 mm) in women with dense breasts at high statistical
significance level. Further testing of this promising result is suggested.
Author Disclosures:
V.Z. Marmarelis: Founder; Marmarelis. Patent Holder; Marmarelis.
Shareholder; Marmarelis.
B-0466 14:45
Technical quality assurance in mammasonography within the Austrian
mammography-screening pilot project: concept and first results
S. Wildner1, R. Mittasch2, F. Semturs1, C. Kollmann1; 1Vienna/AT, 2 Wels/AT
(
[email protected])
Purpose: Ultrasound quality assurance is often regarded as not efficient or too
cost-intensive among radiologists. As part of the Mammography Screening
Program starting in Austria, ultrasound is included in primary diagnostics which
is unique for European Mammography Screening Programs. Hence, Technical
Quality Assurance has to be performed for ultrasound devices as well as for
mammography devices. While mammography TQA follows certain protocols
and guidelines especially designed for this purpose, no such documents exist
for ultrasound so far.
Methods
and Materials: A quality assurance test protocol for screening
purposes was developed. Within this protocol simple and fast tests on a
monthly basis should guarantee an optimal image quality and transducer
performance. Only a few test images are acquired and evaluated by in-house
software to quantify loss of elements, signal-to-noise-ratio, and penetration
depth.
Results
Preliminary results obtained during the pilot phase of the program
show that within 40 institutions comprising 49 ultrasound devices and 53
transducers 7 (13.5%) severe transducer failures were found which were not
recognised by the radiologists.
Conclusion
We can prove that even without sophisticated and expensive aids
such as phantoms it is possible to detect failures and thus improve image
quality by using just simple settings. Technical quality assurance is essential in
ultrasound diagnostics and need not be cost-intensive or complicated.
S235
BA C D E F G
Friday
B-0467 14:54
Review of 3000 automated breast ultrasound scanners in dense-breasted
women: analysis of results in the detection of benign and malign lesions
A. Domingo, F. Gras, C. Cusidó, X. Salvador; Tarragona/ES
(
[email protected])
Purpose: Our aim was to evaluate the use of automated 3D breast ultrasound
in the detection of benign and malign lesions.
Methods
and Materials: Four breast radiologists (experience range 9-35
years) reviewed 3,000 automated 3D ultrasound breast scanners in breast-
densed women, who also underwent screening mammography. Patients with
history of known breast cancer were excluded. A standardised scanning
technique was performed by well-trained radiographers, thus allowing a
decrease in undesired technical artefacts.
Results
80% of the reviewed scanners were classified as benign or probably
benign (BI-RADS 1 to 3) and 20% were classified as suspicious or malign (BI-
RADS 4 and 5). Malign lesions were histologically proven. Multiplanar views
allowed better characterisation of lesions: anatomical precise location (nipple
and skin distance), clock position, shape, margins, ecogenicity, surrounding
tissue changes and size. ABVS lessens interobserver variability when
measuring lesions. Radiographers performed the scans, shortening the
radiologist's reporting time (mean time 10 minutes per study).
Conclusion
Rate detection of benign and malign lesions using ABVS is
similar to hand-held ultrasound. However, the use of multiplanar
reconstructions allows better characterisation of lesion size and exact location,
especially useful in follow-up of benign lesions. ABVS is a promising diagnostic
Method
with good interobserver reliability. It increases breast cancer detection
rate in breast-densed women when combined with adjoint mammography.
B-0468 15:03
Diagnostic performance of breast acoustic radiation force impulse
imaging in the clinical setting
P. Kapetas
1, P.A.T. Baltzer1, P. Clauser2, O. Abeyakoon3, K. Pinker-Domenig1,
M. Bernathova1, R. Woitek1, T.H. Helbich1; 1Vienna/AT, 2Udine/IT, 3London/UK
(
[email protected])
Purpose: To evaluate quantitative breast acoustic radiation force impulse
(ARFI) imaging in the clinical setting.
Methods
and Materials: Fifty-eight patients (age range 21-82, mean age
51.7) receiving ARFI imaging (Virtual Touch, Siemens Acuson S3000, 9 MHz
transducer) as part of their diagnostic ultrasound workup were investigated
between june and september 2013. Two ARFI measurements of identified
lesions were performed independently by two out of a pool of five different
radiologists experienced in breast imaging. The measurement itself took 4
seconds. Regions of Interest (ROI) were placed into the lesion and the
adjacent fatty tissue. The overall exam ination time was below 1 minute. ROC
analysis was used for calculating diagnostic performance of ARFI
measurements. The reference standard was either established by
histopathology or imaging findings.
Results
There were 22 malignant and 36 benign lesions. Both ARFI
measurements showed equal diagnostic performance as measured by the
area under the ROC curve (0.780 and 0.783, respectively; P > 0.05). A cut-off
value of ~3m/s revealed a sensitivity and specificity of 81.8/77.8%
(measurement 1) and 85.3/61.1% (measurement 2).
Conclusion
ARFI provides quantitative data valid for differentiation between
benign and malignant breast lesions. ARFI measurements are fast and can
thus be implemented into routine ultrasound workup of breast lesions.
B-0469 15:12
Acoustic radiation force impulse imaging value in differentiating benign
and malignant breast nodules
M. Magalhaes
1, P. Belo Oliveira1, J. Casalta-Lopes1, Y. Costa2, M. Gonçalo1,
P. Gomes1, F. Caseiro-Alves1; 1Coimbra/PT, 2Faro/PT
(
[email protected])
Purpose: To evaluate the role of acoustic radiation force impulse imaging
(ARFI) for the differential diagnosis between benignancy and malignancy of
breast tumors.
Methods
and Materials: The authors performed B-mode US and ARFI in 83
patients with breast lesions, subsequently characterised by percutaneous
biopsy. Shear wave velocity (SWV) was obtained within the lesion and in the
surrounding parenchyma (m/s). SWV measurements and lesion-to-
parenchyma ratio (LTPR) were calculated. For differentiation between
benignancy and malignancy receiver operating characteristic (ROC) curves
were plotted for each parameter and cut-off values determined according to
Youden's Index. Statistical significance was achieved if p < 0.05.
Results
A total of 92 breast lesions were included, (57 benign and 35
malignant nodules). Intra-lesional SWV was significantly higher for malignant
neoplasms compared to benignancy (average of 9.14m/s vs. 3.45m/s;
p < 0.001). LTPR was also significantly higher for malignant lesions (3.046 vs.
1.443; p < 0.001). No difference in parenchymal SWV was registered among
groups (p=0.071). ROC curves revealed significant discriminative power for
intra-lesional SWV [area under curve (AUC)=0.980; p < 0.001] and LTPR
(AUC=0.950; p < 0.001). A cut-off value of 6.595m/s has a sensitivity and
specificity of 88.6% and 96.4%, respectively. For LTPR a cut-off of 2.181 was
found, providing a sensitivity of 88.6% and specificity of 91.1%.
Conclusion
Quantitative elasticity measurements may be used as a potential
biomarker for characterisation of breast lesions reducing the number of
unnecessary biopsies.
14:00 - 15:30 Room G/H
Genitourinary
SS 607
Gynaecological and bladder tumours
Moderators:
C.D. Alt; Heidelberg/DE
R. Manfredi; Verona/IT
B-0470 14:00
Semi-quantitative dynamic contrast-enhanced (DCE) MRI in preoperative
staging of patients with cervical carcinoma: preliminary results
A.C. Cadonici, D. Ippolito, P. Bonaffini, O. Minutolo, V. Besostri, S. Sironi;
Monza/IT (
[email protected])
Purpose: To assess the value of semiquantitative DCE parameters in cervical
cancer to find any difference between neoplastic tissue and normal cervical
tissue, being tumour grade the standard of reference.
Methods
and Materials: Thirty patients with cervical cancer were enrolled in
our study. Scanning protocol included multiplanar T1- and T2-weighted TSE
and 10 dynamic T1-weighted GE sequences obtained during the administration
of contrast medium (overall time: 5 minutes and 66 s). Perfusion colour maps
were generated on a dedicated software and two regions of interest (ROIs)
were manually drawn on the tumour and on normal cervical tissue to generate
time-signal intensity curves. Relative enhancement (RE%), maximum
enhancement (ME%), maximum relative enhancement (MRE%) and time to
peak (TTP) were calculated and statistically analysed both for neoplastic and
normal cervical tissues.
Results
Semi-quantitative analysis showed the following perfusion values for
cervical cancer: RE: 92.26% ±49.34; ME: 1123.96% ±679.70; MRE:
96.48%±58.29; TTP: 201.91s ±79.79. Corresponding values calculated in
cervical tissue were: RE: 148.31% ±52.39; ME: 1620.23% ±470.05; MRE:
148.54%±52.43; TTP: 235.24s ±72.04. RE, ME and MRE were significantly
(p < 0.05) lower in neoplastic tissue compared to cervical tissue. ME, MRE and
RE were also higher in G1 than in G2-G3 tumours.
Conclusion
Perfusion parameters differ significantly between cervical cancer
and normal cervix; moreover, tumour perfusion parameters proved to decrease
according to tumour grade.
B-0471 14:09
Value of diffusion-weighted imaging in predicting parametrial invasion in
stage Ia2-IIa cervical cancer
C. Jeong
1, J. Park1, C. Kim1, S. Park1, B. Park1, B. Kim2, S. Kwon1, M. Cha1,
H. Kim1; 1Seoul/KR, 2Rochester, MN/US (
[email protected])
Purpose: We investigated the value of diffusion-weighted imaging (DWI) in
evaluating parametrial invasion (PMI) in sta ge IA2-IIA uterine cervical cancer.
Methods
and Materials: A total of 117 patients with stage IA2-IIA uterine
cervical cancer who underwent preoperative MRI and radical hysterectomy
were included. Preoperative clinical variables such as age, serum squamous
cell (SCC) antigen level, FIGO stage, and biopsy results and MRI variables
including tumor size, tumor ADC, presence or absence of PMI or lymph node
metastases were analysed and compared between the groups with and without
pathologically proven PMI.
Results
Pathologic PMIs were identified in 32% of patients (37/117). All
variables except age were significantly different between patients with and
without pathologic PMI (all P
< 0.05). All variables except serum SCC antigen
were also significantly correlated with pathologic PMI on univariate analysis (all
P
< 0.05). Multivariate analysis indicated that PMI on MRI ( P < 0.001) and
tumor ADC ( P= 0.029) were independent predictors of pathologic PMI. The
area under the curve of PMI on MRI increased significantly from 0.793 to 0.872
when combined with tumor ADC ( P= 0.002). The false negative rate (FNR) of
PMI on MRI was 10.1% (7/69). When samples were further stratified with tumor
ADC, the FNR decreased to 2.0% (1/49).
Conclusion
In stage IA2-IIA cervical cancer, tumor ADC and PMI on MRI
seem to be independent predictors of pathologic PMI. Combining the two
predictors improved the diagnostic performance of the identification of patients
at low-risk for pathologic PMI.
S236
BA C D E F G
Friday
B-0472 14:18
Comparison of magnetic resonace imaging and transvaginal ultrasound
in the staging of invasive cervical cancer
F. Moloney, D. Ryan, M. Twomey, M. Hewitt, J. Barry; Cork/IE
(
[email protected])
Purpose: The aim of this prospective study was to compare the diagnostic
accuracy of transvaginal ultrasound (TVS) with magnetic resonance imaging
(MRI) in the staging of invasive cervical cancer using surgical histology as the
gold standard.
Methods
and Materials: This was a prospective, operator-blinded,
interdisciplinary study conducted at a national centre for gynaecological
cancer. We enrolled consecutive patients diagnosed with invasive carcinoma
of the cervix during the period January 2011 to July 2013 (47 patients). All
patients underwent MRI and TVS according to a standardised protocol.
Results
TVS correlated strongly with MRI in the assessment of tumor size.
Sensitivities and specificities for the detection of stromal invasion were 100%
and 55% and 100% and 65% for MRI and TVS respectively. No significant
difference was detected (p value = 0.48). MRI had a false positive rate of 22%
in the assessment of parametrial invasion with TVS correctly down staging 6
patients from stage IIb to Ib.
Conclusion
Accurate staging of cervical cancer is essential as it directs both
treatment strategies and guides prognosis. TVS offers the advantages over
MRI of being relatively inexpensive, non-invasive and potentially widely
available. We have shown TVS to have a similar diagnostic accuracy to MRI
and suggest that transvaginal ultrasound could be used as a first-line imaging
modality to stage invasive cervical cancer. TVS performed by a dedicated
gynaecological radiologist can be a fe asible and economic imaging modality
with a diagnostic accuracy comparable to that of MRI.
B-0473 14:27
MRI of endometrial carcinoma: comparison between T2-weighted,
contrast-enhanced T1-weighted and diffusion-weighted sequences
M. Bonatti
1, J. Stuefer1, G. Schifferle1, N. Oberhofer1, R. Manfredi2, G. Bonatti1;
1Bolzano/IT, 2Verona/IT (
[email protected])
Purpose: To compare the accuracy of T2-weighted, contrast-enhanced T1-
weighted and diffusion-weighted MR images (T2-WI, CET1-WI and DWI) in the
assessment of myometrial and cervical stromal infiltration by endometrial
carcinoma (EC).
Methods
and Materials: Fifty patients with histologically proven EC who
underwent preoperative MRI and surgery at our Institution over a 30-month
period have been included in our retrospective study; informed consent was
waived. Two radiologists independently evaluated T2-WI, CET1-WI and DWI of
each patient and assessed: depth of myometrial invasion (more/less 50%) and
presence of cervical stromal infiltration (Yes/No); a pathologist reviewed
histological specimens by considering th e same variables. Radiological
findings have been compared with path ological ones by means of Fisher's
exact Test.
Results
At histology, myometrial infiltration was 50% in 17/50 (34%); at MRI,
myometrial infiltration was correctly assessed in 43/50 (86%) of the cases
when evaluating T2-WI, in 43/50 (86%) when evaluating CET1-WI and in 45/34
(90%) when evaluating DWI (P > 0.05). At histology, cervical stromal infiltration
was present in 9/50 (18%) of the cases and absent in 41/50 (82%); at MRI,
cervical stromal infiltration was correctly assessed in 46/50 (92%) of the cases
when evaluating T2-WI, in 46/50 (92%) when evaluating CET1-WI and in
46/50 (92%) when evaluating DWI (P > 0.05).
Conclusion
No statistically significant differences have been found in the
accuracy of T2-WI, CET1-WI and DWI in evaluating myometrial and cervical
stromal infiltration by endometrial carcinoma; therefore, DWI may replace
CET1-WI, always in addition to the more "anatomical" T2-WI, for "T" staging of
endometrial carcinoma.
B-0474 14:36
Conventional MR imaging combined with perfusion and diffusion
weighted imaging in the pre-operative assessment of endometrial cancer
A.C. Cadonici, D. Ippolito, O. Minutolo, P. Bonaffini, M. Colombo, S. Sironi;
Monza/IT (
[email protected])
Purpose: To assess the role of semiquantitative DCE and quantitative DWI
parameters in patients with endometrial cancer for the evaluation of tumour
aggressiveness, being tumour grading the standard of reference.
Methods
and Materials: 60 patients with biopsy-proven endometrial cancer
who underwent 1.5 T MR staging examination were prospectively enrolled.
Imaging protocol included multiplanar T1 and T2 weighted TSE sequences,10
dynamic T1 weighted gradient echo sequences during the administration of
Gadolinium (overall time:5 minutes and 66 seconds)and DWI sequences (b
values:0 and 1000 mm2/sec).Colour perfusion and ADC maps were generated
using a dedicated software.Relative Enhancement (RE %),Maximum
Enhancement (ME %),Maximum Relative Enhancement (MRE %),Time To
Peak (TTP %)and mean ADC values were calculated by manually drawing a
region of interest (ROI)on neoplastic tissue and normal myometrium and then
statistically analysed.
Results
Histopathological analysis confirmed the presence of endometrial
carcinoma in all the patients.According to Wilcoxon signed rank test,neoplastic
tissue showed significantly lower (p < 0.001) values of
RE (64.57 %± 36.27);ME (889, 67 % ± 449.96) and MRE (77.60% ± 38.13) as
compared to normal myometrium (RE 153.39% ± 55.56; ME
1817.01% ± 707.22;MRE 159.89 % ± 53.49).TTP was significantly higher in
neoplastic lesion than in normal myometrium (375.84 s ± 1588.86 vs
195.72s ± 76.74). Mean ADC value of neoplastic tissue was 781.60 ± 233.09 x
10-3 mm2/s, significantly lower (p < 0.001) than in
myometrium (1594.20 ± 375.0 x 10-3 mm2/s).Moreover ME and RE showed
higer perfusion values in G1 tumors than in less differentiated lesions.
Conclusion
Perfusion parameters and mean ADC differ significantly between
endometrial cancer and normal myometrium, potentially reflecting their
different micorscopical features.
B-0475 14:45
Assessment of aggressiveness of epithelial ovarian cancers: correlation
of apparent diffusion coefficient with histologic grade and clinical stage
J.-W. Oh, S. Rha, J. Byun; Seoul/KR (
[email protected])
Purpose: The purpose of this study was to correlate the apparent diffusion
coefficient (ADC) value of an epithelial ovarian cancer with histologic grade
and postsurgical stage.
Methods
and Materials: Forty-three patients with pathologically proven
epithelial ovarian cancers, including well-differentiated carcinomas (WDC; n =
7), moderately differentiated carcinomas (MDC; n = 27), and poorly
differentiated carcinomas (PDC; n = 9) were enrolled in this study. All patients
underwent preoperative pelvic MRI including diffusion-weighted images with b
value of 0 and 1000 s/mm
2 at 3.0-T unit. The mean ADC values of the solid
portion of ovarian tumours were measured by two radiologists. Histologic grade
and postsurgical stage were assessed. The mean ADC values of ovarian
cancers were compared among the different histologic grades using one-way
ANOVA. Independent sample t-test was used for the comparisons of ADCs
between early stage tumour (FIGO stage I) and advanced tumour (FIGO stage
II, III, and IV).
Results
The mean ADC values of the solid portion of epithelial ovarian
cancers significantly differed between those of WDC and MDC (p=0.013),
WDC and PDC (p=0.010). However, there was no significant difference
between those of MDC and PDC (p=0.983). A significant difference was found
in the mean ADC values between early stage cancers and advanced cancers
(p=0.011). The mean ADC values showed significant correlation with histologic
grade (rho=-0.446, p=0.003) and postsurgical stage (rho=-0.425, p=0.005).
Conclusion
The mean ADC values of the solid portion of epithelial ovarian
cancers strongly correlate with histologic grade and postsurgical stage.
B-0476 14:54
Impact of ADNEXMR SCORING system on the clinical management of
adnexal masses
I. Thomassin-Naggara, E. Aubert, M. Ballester, M.-F. Carette, E. Darai,
M. Bazot; Paris/FR (
[email protected])
Purpose: To retrospectively apply the MRI scoring system (ADNEXMR
SCORING system) designed for characterisation of indeterminate adnexal
masses to assess its value in clinical practice.
Methods
and Materials: Our study population comprised 394 women (mean
age:45, range:18-88) having 497 adnexal masses, who underwent MRI
between January 2008 and October 2010. Surgical pathology or at least a one-
year imaging follow-up for each patient was recorded. Blinded to final
diagnosis, patients were stratified into five categories according the
ADNEXMRSCORE. According to the ADNEXMRSCORE, patients classified as
ADNEXMRSCORE2 and 3 would have been managed with follow-up scans
whereas patients classified as ADNEXMR SCORE 4 and 5 would have been
operated. This theoretical ADNEXMRSCORE management was compared to
the routine clinical management performed for each patient.
Results
Among patients scored as 2 or 3 (n=317), no cancer was found in
masses larger than 6 cm. Excluding all patients with formal indication of
surgical removal (symptomatic women (n=97), infertile (n=19) or personal
history of ovarian malignancy (n=3)), surgery would have been avoided in
20/198 (10.1%), 29/198 (14.5%), and 44/198 (22.2%) women having adnexal
masses lower than 4 cm, 5 cm and 6 cm, respectively. Among patients scored
4 or 5, treatment planning would have been changed in only 3/77 (3.9%)
women who would undergo surgery for benign lesions.
Conclusion
Our study suggests that an optimal management could be
achieved in patients with indeterminate adnexal masses when using
ADNEXMR SCORING system, allowing a significant decrease (10%) of
surgical recourse. A prospective study is required to confirm these data.
S237
BA C D E F G
Friday
B-0477 15:03
Histogram analysis of apparent diffusion coefficient in urinary bladder
lesions: correlation with pathological findings
S. Suo, X. Chen, Y. Fan, L. Wu, Q. Yao, J. Xu; Shanghai/CN
(
[email protected])
Purpose: To determine if histogram analysis of apparent diffusion coefficient
(ADC) can help differentiate bladder benign lesions from malignant lesions and
distinguish bladder tumours of different T stages.
Methods
and Materials: In all, 52 patients with bladder lesions, including
benign lesions (n = 7) and malignant lesions (n = 45; T1 stage or less, 23; T2
stage, 7; T3 stage, 8; T4 stage, 7), were retrospectively evaluated. ADC maps
were obtained at two b-value combinations (b = 0, 700 s/mm 2 and 0, 1500
s/mm2). Parameters of histogram analysis of ADC included mean, kurtosis,
skewness and entropy. The correlations between these parameters and
pathological results were revealed.
Results
Significant differences were found in mean ADC values obtained at
both b-value combinations among patients of different pathological groups
(P < 0.001). For ADC maps obtained at b-value combination of 0 and 1500
s/mm2, there were also statistically signi ficant differences in kurtosis (P =
0.009) and skewness (P = 0.039), and the area under the receiver operating
characteristic curve (AUC) for mean ADC was statistically significant in the
differentiation of benign lesions and malignant lesions (AUC, 0.87; P < 0.05),
and in the differentiation of T stages (AUC, 0.77-0.90; P < 0.05 for all
comparisons). Kurtosis ADC was helpful for classifying stage T4 (AUC, 0.85;
P < 0.05).
Conclusion
A combination of mean ADC and kurtosis ADC at b-value
combination of 0 and 1500 s/mm2 is more accurate for assessment of bladder
lesions of different pathological groups when compared with mean ADC alone.
B-0478 15:12
Estimation of bladder carcinoma histologic grade with diffusion-weighted
MR imaging
H. Wang, Y. Guo, S. Li; GuangZhou/CN (
[email protected])
Purpose: To compare the diagnostic efficacy of the apparent diffusion
coefficient (ADC) versus a normalised ADC (nADC) value in estimation of
bladder urothelial histologic grade and to identify an optimal reference standard
for nADC values in bladder tissue.
Methods
and Materials: Thirty patients who underwent standard preoperative
bladder DW-MRI examination (b=0.1000 s/mm
2) were recruited into the study
between November 2011 and May 2013. In all cases urothelial carcinoma was
confirmed by histopathology. ADC was obtained for each tumour. Reference
tissues from urine in bladder lumen, the obturator internus and gluteus
maximus were used to evaluate nADC which was calculated as: ADC (tumour
lesion)/ADC (reference standard). A receiver operating characteristic curve
(ROC) was constructed for each of the three nADC tissues and their ability to
differentiate between high- and low-grade bladder carcinoma were compared
to identify an optimal reference standard for nADC calculation.
Results
The ADC (mean ±SD) for low- and high-grade bladder carcinoma
were 1.112 ±0.159 and 0.772 ±0.091, respectively (P < 0.001). The area under
the ROC curve of the ADC were 0.985, 0.995, 0.960 and 0.945, respectively in
bladder tumour, urine, obturator internus and gluteus maximus (P < 0.001).
Conclusion
DW-MRI can be used to non-invasively estimate the histological
grade of bladder urothelial carcinoma. Urine in bladder lumen can be used as
an ideal reference standard for nADC calculation. The differential diagnostic
efficacy of nADC is superior to that of the ADC value.
B-0479 15:21
Value of MDCT in the detection of lymph node metastases in patients
with carcinoma of the urinary bladder: correlation of imaging and
histopathological findings in 274 patients
T. Zahel, T. Maurer, T. Horn, E.J. Rummeny, K. Holzapfel;
Munich/DE (
[email protected])
Purpose: To evaluate multi-detector computed tomography (MDCT) in the
detection of lymph node metastases in patients with urothelial carcinoma of the
urinary bladder.
Methods
and Materials: Two-hundred and seventy-four patients with
urothelial carcinoma of the bladder were preoperatively scanned by MDCT
(sensation 64, siemens; portal venous phase of abdomen and pelvis). Based
on anatomical levels, a 12-field-based approach was used independently by
two radiologists to analyse the presence of lymph node metastases on CT
scans. Lymph nodes were classified using a 5-point scale (1: definitely benign
2: most likely benign 3: uncertain 4: most likely malignant 5: definitely
malignant). Results from radiological analysis were correlated with findings of
histopathological results after radical pelvic lymphadenectomy in all patients.
Correlations were performed on a field and patient basis.
Results
In 65 of 274 patients (24%), lymph node metastases were confirmed
by histopathological analysis. On a patient basis, sensitivity, specificity, positive
predictive value (PPV), negative predictive value (NPV), and accuracy of
MDCT in the detection of lymph node metastases were 65%, 93%, 90%, 73%,
and 79%, respectively. Using the field-based method, 1983 fields of 274
patients could be evaluated. Of these, 140 fields (7%) included lymph node
metastases. Sensitivity, specificity, PPV, NPV, and accuracy were 52%, 98%,
96%, 67%, and 75%, respectively, with this method.
Conclusion
MDCT was not sensitive, but highly specific in the detection of
lymph node metastases in patients with urothelial carcinoma of the bladder.
14:00 - 15:30 Room I/K
Neuro
SS 611
Brain tumour staging and therapy
Moderators:
K. Ahlström Riklund; Umea/SE
S. Bisdas; Tübingen/DE
B-0480 14:00
Diffusion kurtosis imaging in grading of brain glioma malignancy
A. Tonoyan1, I.N. Pronin1, L. Fadeeva1, D. Pitskhelauri1, E. Farrher2,
F. Grinberg2, V. Kornienko1; 1Moscow/RU, 2Juelich/DE (
[email protected])
Purpose: Diffusion kurtosis imaging (DKI) has been introduced as an
advanced extension of diffusion tensor imaging (DTI). DKI characterises the
diffusion deviation degree from the Gaussian model. The goal of this study is to
assess the diagnostic efficacy of DKI in glioma grading.
Methods
and Materials: 29 patients with cerebral gliomas underwent imaging
with a 3-T MR scanner. A spin-echo EPI sequence was used to acquire DKI
using b values of 0, 1000 and 2500 s/mm² and 60 gradient directions. The DT
parameters (mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD),
fractional anisotropy (FA), relative anisotropy (RA)) and the DK parameters
(mean kurtosis (MK), axial kurtosis (AK), radial kurtosis (RK), kurtosis
anisotropy (KA)) were compared in the solid parts of 14 low-grade gliomas
(LGG), and 15 high-grade gliomas (HGG) (P < 0.05 significance level, t-test).
Results
MK, AK, RK, KA for HGG and LGG were 0.677 ±0.309, 0.613±0.239,
0.718±0.390, 0.115 ±0.113 and 0.462 ±0.117, 0.442 ±0.108, 0.447 ±0.174,
0.039±0.017, respectively. DK parameters significantly differed between
gliomas grades (MK, P=0.02; AK, P=0.02; RK, P=0.025; KA, P=0.02). MD, AD,
RD, FA, RA for HGG and LGG were 1.382 ±0.577 (×10-3 mm2/sec),
1.564±0.593 (×10-3 mm2/sec), 1.168± 0.606 (×10-3 mm2/sec), 0.151 ±0.112,
0.090±0.070 and 1.867 ±0.394 (×10-3 mm2/sec), 2.040 ±0.437 (×10-
3 mm2/sec), 1.780 ±0.379 (×10-3 mm2/sec), 0.083± 0.042, 0.053 ±0.022,
respectively. FA significantly increased with higher malignancy (P=0.04),
whereas MD, AD and RD significantly decreased with that (P=0.01, 0.02,
0.003, respectively). The highest sensitivity and specificity for discriminating
between HGG and LGG were found for MK (93% and 94%, respectively).
Conclusion
DKI demonstrated a promising potential to differentiate among
glioma grades and provides added value in comparison with conventional DTI.
B-0481 14:09
Glioma grading based on perfusion MRI: a normalised blood volume
histogram metrics quantification study
K. Nikiforaki1, V.K. Katsaros2, G. Manikis1, K. Marias1, G. Strantzalis2,
N. Papanikolaou1; 1Iraklion, Crete/GR, 2Athens/GR (
[email protected])
Purpose: To compare the diagnostic accuracy of normalised Blood Volume
(nBV) histogram metrics to differentiate low from high grade gliomas.
Methods
and Materials: Forty nine patients (22 female, 27 male) with
histologically confirmed gliomas were included. Group A comprised 13 patients
with low grade gliomas (all grade II) while group B comprised 36 patients (4
grade III and 32 grade IV). Three-dimensional tumor segmentation was based
on intensity level clustering in T2 FLAIR for the non enhancing lesions or post
contrast T1 weighted images for the enhancing lesions. Dynamic Susceptibility
Contrast (DSC) perfusion was applied in all patients. Leakage corrected nBV
maps were created from all pixels included in the tumor volume. Minimum,
maximum, mean, standard deviation, median, 5%, 30%, 70% and 95%
percentiles, as well as, normalised peak height of the nBV histograms were
calculated for both groups. Resulting nBV histograms were analysed for each
patient to calculate the area under the curve of receiver operating
characteristics (AUROC) for the above mentioned histogram metrics.
S238
BA C D E F G
Friday
Results
Both V30 (threshold value: 0.478) and Median (threshold value:
0.671) histogram metrics were resulted in 86.11% sensitivity and 100%
specificity, to discriminate high form low grade gliomas, however the
V30 AUROC was higher than that of Median (0.949 and 0929, respectively).
Conclusion
Normalised Blood Volume histogram analysis is an accurate
Method
for the differentiation between low and high grade gliomas.
Author Disclosures:
K. Nikiforaki: Employee; N. Papanikolaou & Associates. N. Papanikolaou:
CEO; N. Papanikolaou & Associates. Founder; N. Papanikolaou & Associates.
B-0482 14:18
Prognostic value of apparent diffusion coefficient (ADC) values and its
correlation with methylguanine-DNA-methyltransferase (MGMT) promoter
methylation status on glioblastoma multiforme (GBM)
R. Zalazar, M.D. Hernández, M. Páramo, P. Slon, M. Millor Murunzabal,
J. Solorzano Rendon, M. Ribelles, J. Zubieta, M. Garcia de Eulate;
Pamplona/ES (
[email protected])
Purpose: To analyse whether apparent diffusion coefficient (ADC) values
correlate with survival and with methylguanine-DNA-methyltransferase
(MGMT) promoter methylation status on glioblastoma multiforme (GBM).
Methods
and Materials: 57 patients with untreated GBM before surgery were
analysed. Patients were followed-up for at least 12 months or until death. A
ROI were drawn on ADC-map in the highest restriction region of the tumor and
on the normal-appearing contralateral white matter (NCWM). ADCmin-values
were evaluated as well as ADC-index defined as a ratio between tumoral
ADCmin and NCWM-ADCmean. MGMT-status, tumoral volume, residual
volume, progression-free survival (P FS) and overall survival (OS) were
evaluated. Three groups were analysed, Group1=ADC-index > 0.7 and MGMT-
methylated-status, Group2=ADC-index < 0.7 and MGMT-non methylated-
status, and Group3=MGMT-non-methyltaed-status independent of ADC-index.
Kaplan-Meier and Cox-regression model were performed.
Results
57 patients were evaluated. 46 patients had complete resection.
Presurgical tumoral volume (mean=42.4 cm
3) and post-surgical volume
(mean=0.57 cm3) had no association with survival. MGMT-status (n=53) was
not methylated in 26. On Kaplan-Meier analyses MGMT-status correlated
better with PFS (p=0.002), while ADC-index correlate better with OS
(p < 0.001). Group1 had better prognosis than Group2 in PFS (p=0.014) and
OS (p 0.7 had better OS than ADC-
index< 0.7 (p=0.027). Patients with MGMT-methylated-status and
ADCindex 0.7 (p < 0.001).
The ADC-index value of 0.7 represents the best cut-off value for predicting OS.
ADC-index was a significant predictor variable on Cox regression model
(p0.003).
Conclusion
The combined use of ADC-index and MGMT-status are stronger
predictors than using separated in GBM. ADC-index value is a new prognostic
parameter in GBM.
B-0483 14:27
MGMT promoter methylation status is associated with specific imaging
features and MR imaging quantitative parameters in high-grade gliomas
T. Jiang; Shanghai/CN (
[email protected])
Purpose: To retrospectively evaluate the relationship between the MGMT
methylation status and the quantitative imaging parameters of MR in HGGs.
Methods
and Materials: 24 patients whose MGMT promoter methylation
status was available were enrolled retrospectively. MR examinations were
performed before surgery. ADC and FA from DTI, and the regional cerebral
blood parameters from PWI and parameters from IVIM were measured for
enhancing tumours.
Results
ADC values tended to be higher in the methylated HGGs than in the
unmethylated HGGs (p M=M0.055), the ADC ratio was significantly higher in the
methylated tumours versus the unmethylated tumours (p M=M0.032). The FA and
FA ratio showed significantly lower values in the methylated HGGs as
compared with those in the unmethylated HGGs (p M=M0.006 and pM=M0.007). The
f values of methylated HGGs (0.156 ± 0.039 [standard deviation]) were
significantly larger than those of unmethylated HGGs (0.066 ± 0.031) (P
=.003). The D* values of unmethylated HGGs (21.99 x 10-3 mm2/sec ± 19.01)
were significantly smaller than those of methylated HGGs (42.64 x 10-
3 mm2/sec ± 20.17) (P =.022). Regarding imaging features, only ill-defined
margin was seen more frequently in the methylated group than in the
unmethylated group (45.5% versus 7.7%, respectively, pM=M0.048).
Conclusion
MGMT promoter methylation status is associated with a specific
imaging feature (an ill-defined margin) and several imaging parameters (a
higher ADC, lower FA and higher perfusion parameters) of HGGs.
B-0484 14:36
Comparison of diffusion tensor, dynamic susceptibility contrast MRI and
99mTc-Tetrofosmin brain SPECT for the detection of recurrent high-grade
glioma
A. Zikou, G. Alexiou, S. Tsiouris, A. Goussia, P. Kosta, S. Vourgaris,
P. Tsekeris, A. Fotopoulos, M.I. Argyropoulou; Ioannina/GR
(
[email protected])
Purpose: Treatment-induced necrosis is a relative frequent finding in patients
treated for high-grade gliomas. Differentiation by imaging modalities between
glioma recurrence and treatment-induced necrosis is not always
straightforward. Herewith, we compared diffusion tensor, dynamic susceptibility
contrast MRI and
99mTc-Tetrofosmin brain SPECT for the differentiation of
glioma recurrence from treatment-induced necrosis.
Methods
and Materials: We prospectively studied 30 patients who were
treated for high-grade glioma and had a suspicion of recurrent tumour on
follow-up MRI. All patients received surgical resection of the tumour, followed
by postoperative standard radiotherapy with chemotherapy. No residual tumour
had been found in the imaging follow-up immediately after initial treatment. All
patients underwent brain MRI and within a week underwent
99mTc-Tetrofosmin
brain SPECT.
Results
Both 99mTc-Tetrofosmin brain SPECT and dynamic susceptibility
contrast MRI could discriminate the two clinical entities with 100% sensitivity
and 100% specificity. An ADC ratio cut-off value of 1.27 could differentiate
recurrence from treatment-induced necrosis with 65% sensitivity and 100%
specificity and a FA ratio cut-off value of 0.47 could differentiate recurrence
from treatment-induced necrosis with a 57% sensitivity and 100% specificity. A
significant correlation between
99mTc-Tetrofosmin uptake ratio and rCBV was
found (P=0.002). A significant negative correlation was also found between
99mTc-Tetrofosmin uptake ratio and ADC ratio (P=0.031).
Conclusion
Dynamic susceptibility contrast MRI and brain SPECT with 99mTc-
Tetrofosmin had the same accuracy and may be used to detect recurrent
tumour. DTI also showed promise for the detection of recurrent tumour, but
was inferior to both dynamic susceptibility contrast MRI and brain SPECT.
B-0485 14:45
Differential diagnosis of therapy-related changes and recurrent
intracranial tumours using perfusion MRI and methionine PET
R.S. Romanos-Zapata, T. Danfors, J. Wikström, R. Raininko; Uppsala/SE
(
[email protected])
Purpose: Irradiation and chemotherapy may cause contrast enhancing tissue
changes difficult to differentiate from a recurrent tumor. We evaluate the value
of perfusion MRI and methionine PET in di fferential diagnosis of neoplastic and
non-neoplastic changes.
Methods
and Materials: 21 patients, treated earlier for an intracranial
neoplasm, were recruited in the study after development of a new contrast
enhancement. They underwent standard brain MRI and perfusion study with
DSC technique at 1.5 T, and
C11methionine PET. The diagnosis was confirmed
histologically or with a long time follow-up. Patients with insufficient follow-ups
or inconclusive final diagnosis (stabl e lesions in patients receiving
temozolomide during follow-up) were excluded. The final material consisted of
16 patients who had 19 lesions. Ten of the lesions were neoplastic (all
histologically confirmed) and nine lesions were non-neoplastic. The lesion was
recorded as neoplastic on perfusion MRI if the RBV ratio of the lesion/the same
area in the healthy side was > 2 and on PET if the lesion/normal cortex ratio
was 2.0.
Results
14/19 lesions (74%) were correctly diagnosed on perfusion MRI and
15/19 lesions (79%) on PET. Sensitivity and specificity for neoplastic lesions
were 80% and 67% on perfusion MRI and 100% and 56% on methionine PET,
respectively. Diagnosis was correct or false with both methods in 11 and 1
lesions, respectively, and discrepant in 7 lesions.
Conclusion
Accuracy of both methods is roughly the same. Methionine PET
is highly sensitive for recurrent tu mors but produces a lot of false positive
diagnoses.
S239
BA C D E F G
Friday
B-0486 14:54
Differentiation of true recurrence from delayed radiation therapy-related
change of primary brain tumors using advanced MR imaging
D. Kim, S. Choi, J.-H. Kim, C.-H. Sohn; Seoul/KR (
[email protected])
Purpose: To compare dynamic susceptibility contrast imaging, diffusion
weighted imaging and susceptibility weighted imaging (SWI) for the
differentiation of tumor recurrence and delayed radiation therapy (RT)-related
change in patients treated with RT for primary brain tumors.
Methods
and Materials: We enrolled 24 patients treated with RT for varoius
primary brain tumors, who showed newly appeared enhancing-lesions 1year
after completion of RT on follow-up 3 T brain MRI. The enhancing-lesions were
confirmed as recurrence (n=14) or RT-change (n=10) based on
radiological (n=11) or pathologic (n=13) findings. We calculated the mean
values of normalised CBV (nCBV),ADC (apparent diffusion coefficient),and
proportion of dark signal intensity on SWI (proSWI) for enhancing lesions. All
values between two groups were compared using unpaired t-test. A
multivariable logistic regression mode l was used to determine the best
predictor of differential diagnosis between two groups. The cutoff value of the
best predictor obtained from receiver-operating characteristic curve analysis
was applied to the differentiation of RT-change and recurrence,and we
obtained the sensitivity,specificity,and accuracy for the diagnosis.
Results
The mean nCBV values were significantly higher in recurrence group
than RT-change group (2.64vs1.06;P=.004),and mean proSWI were
significantly lower in recurrence group (4.37vs43.92;P <.001). However, no
significant difference was observed in mean ADC values between two
groups (P=.419). Results of multivariable logistic regression analysis showed
that proSWI was the only variable that could be used to independently
differentiate true recurrence from RT-change (P=.001); the
sensitivity,specificity,and accuracy were 78.6%(11of14),100%(10of10),and
87.5%(21of24), respectively.
Conclusion
We found that the proSWI was the most promising parameter for
the differentiation of newly developed enhancing-lesions more than 1year after
RT completion in brain tumor patients.
B-0487 15:03
Evaluation of microvascular permeability with dynamic contrast-
enhanced MRI for the differentiation of primary CNS lymphoma and
glioblastoma: radiologic-pathologic correlation
P. Kickingereder, F. Sahm, B. Wiestler, S. Heiland, H.-P. Schlemmer, W. Wick,
A. von Deimling, M. Bendszus, A. Radbruch;
Heidelberg/DE (
[email protected])
Purpose: Dynamic contrast-enhanced (DCE) MRI can provide in vivo
assessment of the microvasculature in intracranial tumours. The aim of the
present study was to evaluate the diagnostic performance of DCE-MRI derived
vascular permeability parameters, including the volume transfer constant K
trans,
the volume (V e) of extravascular extracellular space (EES), and the flux-rate
constant Kep between EES a nd plasma, for the differentiation of primary CNS
lymphoma (PCNSL) and glioblastoma (GB).
Methods
and Materials: Sixty GB and ten PCNSL were included. Pre-
treatment DCE-MRI with a 3D T1-weighted spoiled gradient-echo sequence
was performed using Dotarem on a 3 T MRI scanner. Perfusion parameters
(K
trans, K ep, and V e) were measured based on the Tofts-Kernmode model.
Mann-Whitney-U test and receiver-operating characteristics (ROC) analysis
were used to compare those parameters between PCNSL and GB.
Histopathological correlation of DCE-M RI findings was performed using Tibor-
Pap impregnation and CD31 immunohistochemistry.
Results
Median K
trans and K ep values were significantly higher in PCNSL
(0.148±0.060 and 0.401 ±0.089) than in GB (0.064 ±0.020 and 0.224 ±0.058)
(p < 0.01, respectively). Median V e values did not differ significantly between
PCNSL (0.429 ±0.174) and GB (0.319± 0.101). On ROC analysis, K trans had the
best discriminative value for differentiating PCNSL and GB (threshold: 0.093,
sensitivity: 90.0%, specificity: 95.0%). Histopathological evaluation revealed
intact vascular integrity in GB despite endothelial proliferation, whereas PCNSL
demonstrated destructed vessel architecture, thereby promoting vascular
disintegrity.
Conclusion
PCNSL demonstrated significantly higher K
trans and K ep values
compared with GB, implying a higher vascular permeability in PCNSL. These
findings correlate with underlying histopathological features, and may be useful
in distinguishing PCNSL from GB.
B-0488 15:12
Multiparametric characterisation of a rat model of glioblastoma by using
MRI and 18 F-FDG PET/CT images
M. Vieira-Leite, P. López-Larrubia; Madrid/ES (
[email protected])
Purpose: Glioblastoma is the most frequent primary brain tumour that carries a
very bad prognosis despite the advances in treating human malignancies. This
study aimed to characterise a rat model of glioma by MRI and PET/CT, the two
versatile tools used in neuroimaging.
Methods
and Materials: Male Wistar rats (N=19) implanted with C6 cells in
their right caudate-putamen and Sham animals (N=5) were used and studied
with MRI using a 7T system to acquire a T2, T2* and T1-weighted images to
yield relaxation time maps, diffusion tension imaging-DTI to obtain mean
diffusivity-(MD) and fractional anisot ropy-(FA) maps, and magnetisation
transfer-(MT) to determine MT ratio maps. Colour-based maps were computed
using a home-made software developed in Matlab. ROIs were drawn in the
tumoural tissue (TT), contralateral hem isphere (CH) and healthy tissue (HT).
Six animals were also submitted to an 18 F-FDG-PET/CT, analysing ROI's in
the T, CH and liver.
Results
TT compared with Sham showed significantly different values of
MTR, T1, T2 and T2*. TT compared to CH was also significant on MTR, MD,
T1, T2 and T2* measurements. When comparing TT and HT, there were
significant differences on MT,FA, T1 and T2. PET/CT showed significantly
higher SUVs on the TT than on CH. Correlation between SUVs and MRI
parameters could not be found.
Conclusion
There are significant differences in MRI parameters related to
inflammation, oedema and hypoxia between TT, CH and HT. 18 F-FDG-
PET/CT provided new information to the MRI. Tumour characterisation can
improve the selection of patients who will benefit from tailored therapies and
their follow-up.
B-0489 15:21
Resection probability maps for quality assessment of glioma surgery
without brain location bias
P.C. de Witt Hamer
1, E.J. Hendriks1, E. Mandonnet2, F. Barkhof1,
A.H. Zwinderman1, H. Duffau3; 1Amsterdam/NL, 2Paris/FR, 3Montpellier/FR
(
[email protected])
Purpose: Intraoperative brain stimulation mapping reduces permanent
postoperative deficits and extends tumour removal in resective surgery for
glioma patients. Successful functional m apping is assumed to depend on the
surgical team's expertise. In this study, g lioma resection results are quantified
and compared using a novel approach, so-called resection probability maps
(RPM), exemplified by a surgical team comparison, here with long and short
experience in mapping.
Methods
and Materials: Adult patients with glioma were included by two
centers with two and fifteen years of mapping experience. Resective surgery
was targeted at non-enhanced MRI extension and was limited by functional
boundaries. Neurological outcome was compared. To compare resection
results, we applied RPMs to quantify and compare the resection probability
throughout the brain at 1 mm resolution. Considerations for spatial
dependence and multiple comparisons were taken into account.
Results
The senior surgical team contributed 56, and the junior team 52
patients. The patient cohorts were comparable in age, preoperative tumour
volume, lateralization, and lobe localisation. Neurological outcome was similar
between teams. The resection probability on the RPMs was very similar, with
none (0%) of 703,967 voxels in left-sided tumours being differentially resected,
and 124 (0.02%) of 644,153 voxels in right-sided tumours.
Conclusion
RPMs provide a quantitative volumetric method to compare
resection results, which we present as standard for quality assessment of
resective glioma surgery because brain lo cation bias is avoided. Stimulation
mapping is a robust surgical technique, because the neurological outcome and
functional-based resection results using stimulation mapping are independent
of surgical experience.
S240
BA C D E F G
Friday
14:00 - 15:30 Room L/M
Cardiac
SS 603a
Functional MR imaging: myocardium and
ventricles
Moderators:
D. Maintz; Cologne/DE
F. Molinari; Lille/FR
B-0490 14:00
Assessment of sub-clinical acute cellular rejection after heart
transplantation: comparison of cardiac imaging and endomyocardial
biopsy
C. Krieghoff, M. Barten, L. Hildebrandt, M. Grothoff, L. Lehmkuhl, C. Lücke,
C. Andres, S. Nitzsche, M. Gutberlet; Leipzig/DE (
[email protected])
Purpose: Comparing the diagnostic value of multi-sequential cardiac magnetic
resonance imaging (CMR) with endomyocardial biopsy (EMB) for detection of
sub-clinical cardiac allograft rejection.
Methods
and Materials: 146 examinations in 73 Patients (mean age 53 ±12
years, 58 male) were performed using a 1.5-Tesla scanner and compared to
EMB results. A multi-sequential protocol was used including T2-weighted short
tau inversion recovery (STIR) for calculation of the oedema ratio (ER), T1-
weighted spin-echo sequence for assessment of global relative enhancement
(gRE) and inversion-recovery sequences to visualise late gadolinium
enhancement (LGE). Cut-off values were defined as <= 2 for ER and 1B was considered as relevant rejection in which all patients received anti-
inflammatory medical treatment.
Results
One-hundred and twenty-seven (127/146=87%) EMBs demonstrated
with no or mild signs of rejection (grades = 1B). Sensitivity, specificity, positive predictive
(PPV) and negative predictive value (NPV) for rejection grade 1B or higher
were as follows: ER: 63%, 78%, 30% and 93%; gRE: 63%, 70%, 24% and
93%; LGE: 68%, 36%, 13% and 87%; with the combination of ER and gRE
with at least 1/2 positive: 84%, 57%, 23% and 96%. A receiver operator
characteristic analysis revealed an area under the curve of 0.724 for ER and
0.659 for gRE.
Conclusion
CMR parameters for myocarditis were also useful to detect sub-
clinical acute cellular rejection after heart transplantation. Comparable results
to myocarditis could be achieved, with a combination of ER and gRE.
B-0491 14:09
Myocardial engraftment assessment of mesenchymal stem patches on
serial high-resolution in vivo cardiac MR in chronic heart failure
E. Blondiaux1, L. Pidial1, G. Autret1, D. Balvay1, E. Audureau2, C. Whilhelm1,
H. Ducou le Pointe1, P. Menasché1, O. Clément1; 1Paris/FR, 2Créteil/FR
(
[email protected])
Purpose: To determine whether the efficiency of epicardial deposit of human
bone marrow-derived mesenchymal stem cells (BMSC) fibrin patch on
chronically-infarcted rat hearts occurred through integration of stem cells from
the patch to the recipient myocardium.
Methods
and Materials: BMSC were labeled with iron oxide nanoparticles
(BMSC*, n=12) or unlabeled (BMSC-, n=10). Patches were applied to region of
ischemia. No patch was applied to control group hearts after myocardial
infarction and median sternotomy (SHAM, n=7). In vivo cardiac MR imaging
was performed on a 4.7 Tesla scanner before, 8 days and 21 days after
transplantation. Therapeutic efficacy was evaluated on cine flash MRI
sequences with left ventricular ejection fraction (LVEF). Cell migration into the
myocardium was evaluated on in vivo T2*-weighted sequences. The results
were compared with histology for the evaluation of iron labeled cells (Perls)
and immunohistochemistry for the presence of human cells (Lamin A/C).
Results
At day 8 and 21 after transplantati on, a statistically significant
difference was found between the LVEF of BMSC* and BMSC- compared with
SHAM (p=0.02 and p=0.03 respectively). Persisting human cells were
identified in the grafted area 21 days after transplantation. Location of dark
areas identified on T2*-weighted MR images corresponded with spatially MR-
matched histological sections and demonstrated that no BMSC* integrated in
the myocardium.
Conclusion
The absence of integration BMSC into the recipient myocardium
and the presence of persisting human cells at day 21 suggest that the
efficiency of these constructs is more closely related to the paracrine effects of
BMSCs.
Author Disclosures:
E. Blondiaux: Research/Grant Support; Société Française de Radiologie.
B-0492 14:18
Myocardial MR spectroscopy (MRS) as early indicator of athlete's heart
and hypertrophic cardiomyopathy
F. Secchi, R. Spairani, M. Petrini, C. Messina, F. Cartia, G. Di Leo,
F. Sardanelli; Milan/IT (
[email protected])
Purpose: To evaluate myocardial energetic metabolism with 31P-MRS and
1H-MRS in order to define early metabolic modifications in athlete's heart.
Methods
and Materials: We prospectively performed a cardiac 1.5-T MR in 30
subjects: 15 athletes (A), 7 HCM patients (H) and 8 healthy volunteers (V).
ECG-triggered true-FISP and 1H-MRS point resolved spectroscopy sequence
were performed. For the 1H-MRS, a single voxel was placed into the septum. A
31P-MRS multivoxel chemical shift imaging sequence was acquired. 1H-MRS
spectra were processed using jMRUI software; 31P-MRS spectra using
Spectroscopy-Argus. Kruskal-Wallis and Jonckheere-Terpstra tests were used.
Results
Ejection fraction (%), indexed end-diastolic volume (ml/m
2), end-
systolic volume (ml/m 2), mass (g/cm 2) and septal thickness (mm) were 65, 84,
31, 70 and 10 for group A, respectively; 68, 73, 20, 81 and 18 for group H,
respectively; 63 (p=0.939), 78 (p=0.058), 29 (p=0.481), 45 (p=0.013) and 6
(p < 0.001) for group V, respectively. Creatine phosphate (PCr), 3ATP and
inorganic phosphate (Pi) were 29, 5.5, 0.4 for group A, respectively; 22, 5.4,
0.4 for group H, respectively; 24 (p=0.281), 5.7 (p=0.877), and 0.0 (p=0.066)
for group V, respectively. PCR/ 3ATP was 5.1 in group A, 3.7 in group H and
4.6 in group V (p=0.441); total creatine was 0.4, 0.6, and 0.0, respectively
(p=0.050); lipids were 0.1, 1.8, and 0.0, respectively (p=0.078).
Conclusion
A reduction of PCR/3 ATP ratio and an increase of lipids are
confirmed in group H. A reduction of PCR/ 3ATP associated with an increase of
lipids could represent an indicator of early stage of HCM.
B-0493 14:27
Left ventricular non-compaction: pathological or normal variant?
J. Weir-McCall, A. Dawson, K. Fitzgerald, C. Papagiorcopulo, M. Lambert,
R.D. White, S. Gandy, A.M. Struthers, J.J.F. Belch, J.G. Houston; Dundee/UK
(
[email protected])
Purpose: There is considerable overlap between Left Ventricular Non
Compaction and other cardiomyopathies, and it has been reported in up to
18% of athletes raising the question whether it is a distinct pathological entity.
To further understand this unusual phenotype we assessed its prevalence in a
healthy population using cardiac magnetic resonance (CMR).
Methods
and Materials: 5000 volunteers > 45 yrs with no history of
cardiovascular (CV) disease and a 10 year risk of CV disease less than 20%
as assessed by the ASSIGN score were recruited to the Tayside Screening for
Cardiac Events (TASCFORCE) study. Those with a B-type natriuretic peptide
(BNP) level greater than their gender specific median were invited for a whole
body cardiovascular MRI. From this group, 500 CMR were assessed, and
LVNC ratios measured on the horizontal long axis and vertical long axis
bSSFP sequences. Non compaction ratio was recorded at end diastole in the
section with the greatest ratio of compacted to non compacted myocardium.
Results
The average non compacted:compacted LV myocardium was 1.79
(IQR 1.38-2.1) with the anterior wall of the mid LV the most common location of
maximmum non compaction. 80 (16%) had a non compaction ratio of > 2.3 (the
current proposed threshold for LVNC diagnosis). Of these the average non
compaction ratio was 2.83 (IQR 2.45-3.05), with an average of 4 segments
involved (IQR 3-6) using the AHA 17 segment model.
Conclusion
The current CMR criteria appears to over diagnose LVNC in
healthy individuals and more stringent diagnostic criteria is required.
B-0494 14:36
Assessment of left ventricular functional and morphological adaptation in
professional soccer players using cardiac MR
M. Regier, E. Tahir, J. Schmidt-Holz, C. Behzadi, R.P. Marschall,
P. Catala-Lehnen, K. Müllerleile, G. Adam, G.K. Lund;
Hamburg/DE (
[email protected])
Purpose: To investigate the effects of intensive daily training related to
professional soccer on morphological and functional parameters of the left
ventricle assessed by cardiac magnetic resonance imaging (CMRI) and to
compare these to the observations in non-athletic healthy volunteers.
Methods
and Materials: In 16 male professional soccer players from the
German Bundesliga team squad of the Hamburger SV and six sedentary
controls CMRI was performed at 1.5 T during active season. For quantitative
CMRI, an electrocardiographically triggered steady-state free precession
(SSFP) cine sequence (TR/TE, 3.2/1.6 ms; pixel-size, 1.7 mm×1.7 mm) was
performed in short- and long-axis views. Quantitative analysis included the
end-diastolic (EDV) and end-systolic volume (ESV), the stroke volume (SV),
left ventricular ejection-fraction (EF) as well as the end-diastolic (EDMM) and
end-systolic myocardial mass (ES MM). Statistical evaluation included
Spearman`s correlation coefficient (CC) and the Wilcoxon test.
S241
BA C D E F G
Friday
Results
In professional soccer players the EDV (230.8 ±20 ml vs.
168.99±42.48 ml; p < 0.02), ESV (101.1 ±16.65 ml vs. 68.28 ±15.81 ml;
p=0.002) and SV (129.73± 15.73 ml vs. 100.71 ±27.26 ml; p < 0.05) were
significantly higher than in non-athletic volunteers. Furthermore, the myocardial
mass was significantly higher in professional soccer players at the end-
diastolic (152.28 ±37.72 g vs. 100.88 ±35.71 g; p=0.015) as well as the end-
systolic (163.4 ±37.8 g vs. 114.4 ±39.3 g; p < 0.03) state whereas the ejection-
fraction was similar in both collectives. At rest, the athlete`s heart rate was
significantly lower (50 vs. 61 beats/min; p=0.01).
Conclusion
Left ventricular adaptations in professional soccer players are
characterised by an increase in functional parameters and myocardial mass.
CMRI allows for an objective quantitative assessment and might help to
differentiate cardiac adaptations from hypertrophic cardiomyopathy.
B-0495 14:45
Cardiac MRI in elite athletes: an it be a final step in the eligibility for
competitive sport after suspicious ultrasonography?
O. Larina, E. Mershina, V.E. Sinitsyn, E. Sidorenko, V. Preobrazhenskiy;
Moscow/RU (
[email protected])
Purpose: To evaluate usefulness and efficacy of CMR in young athletes with
suspicious or inconclusive ultrasonography referring for their eligibility to
competitive sport.
Methods
and Materials: 29 athletes (high league football and hockey players,
athletics; age 24± 5; 27/2 men/women) were examined in 2009-2013. All
athletes had suspicions to cardiac abnormalities according to the results of
echocardiography, ECG and functional examination. CMR was performed with
1.5 T-scanner to detect/rule out LV hypertrophy, arrhythmogenic
cardiomyopathy, myocarditis or congenital heart diseases.
Results
>MR didn't confirm cardiac pathology or found minor non-significant
abnormalities in 16 cases (55.2%). In 5 cases (17.2%) CMR demonstrated the
presence of bicuspid aortic valve with non -significant regurgitation. In 2 cases
(6.9%) athletes had deep myocardial trabeculations without criteria of non-
compaction cardiomyopathy. These athletes kept on doing competitive sports
under the care of cardiologists. In 3 cases (10.3%) CMR revealed LV
hypertrophy, which exceeded criteria established for the "athlete's heart". In 1
case of apical LV hypertrophy with focus of late-enhancement was found.
These athletes were recommended to disco ntinue professional sport activities.
2 sportsmen (6.9%) were referred to cardiac surgeon: the first one had patent
ductus arteriosus (Qp:Qs = 1.35:1), the second one - the complex cardiac
pathology - non-compacted myocardium, ventricular septal and inferior wall
aneurism, atrial septal defect (Qp:Qs = 1.35:1).
Conclusion
CMR provides significant contribution for medical decision-
making in athletes eligibility for professional sport due to its possibilities in the
assessment of ischemia and viability, evaluation of non-ischemic
cardiomyopathies, myocarditis, pericardial disease, congenital heart disease
and cardiac masses.
B-0496 14:54
MR 4D flow-based estimation of pulmonary arterial wedge pressure
U. Reiter, G. Reiter, G. Kovacs, A. Schmidt, H. Olschewski, M.H. Fuchsjäger;
Graz/AT (
[email protected])
Purpose: To evaluate if time-resolved three-directional magnetic resonance
phase contrast imaging (4D-MR-PCI) derived left atrial in- and out-flow patterns
can be employed to estimate pulmonary arterial wedge pressure (PAWP).
Methods
and Materials: 60 patients with suspected pulmonary hypertension
(PH) underwent right heart catheterization for determination of pulmonary
haemodynamics and 4D-MR-PCI of the left atrium. MR-PCI data were
visualised with dedicated software and evaluated for peak velocities v
S and v D
of S- and D-wave of pulmonary veins at the pulmonary venous-left atrial
junctions as well as for the peak velocity v
E of the E-wave at the left atrial-
ventricular junction. Relations between peak velocities, left atrial acceleration
index defined as a LA=2·vE/(vS+vD) and PAWP were analysed by means of
correlation and linear regression analysis.
Results
Whereas no single peak velocity (mean v S=34±12 cm/s, mean
vD=32±8 cm/s, mean vE=50±16 cm/s) correlated strongly with PAWP (r=-0.57, -
0.16 and 0.62 for v S, v D and v E, respectively), the correlation coefficient
between aLA (mean a LA =1.7±0.9) and PAWP was r=0.92. Linear regression of
PAWP on a LA did not depend on the presence of PH (p=0.61 for the intercept,
p=0.87 for the slope) and the standard deviation from the regression line
PAWP=-3.6+8.5·aLA (in mmHg) was 2.0 mmHg.
Conclusion
4D MR-PCI-derived left atrial acceleration index allows an
accurate estimation of PAWP in patients with suspected PH and might,
therefore, be employed as non-invasive marker for the pre- or post-capillary
nature of cardiovascular disorders in general, and PH in particular.
Author Disclosures:
G. Reiter: Employee; Siemens AG.
B-0497 15:03
Towards non-invasive haemodynamic assessment of pulmonary
hypertension
G. Reiter, U. Reiter, G. Kovacs, A. Schmidt, H. Olschewski, M.H. Fuchsjäger;
Graz/AT (
[email protected])
Purpose: Mean pulmonary arterial pressure (mPAP), pulmonary arterial
wedge pressure (PAWP), and transpulmonary pressure gradient (TPG) are
haemodynamic key parameters for defini tion and classification of pulmonary
hypertension (PH). The purpose of the present study was to analyse, if blood
flow patterns derived from time-resolved three-directional magnetic resonance
phase contrast imaging (4D-MR-PCI) can be used to estimate these
parameters in patients with PH.
Methods
and Materials: 33 patients with PH underwent right heart
catheterisation providing mPAP, PAWP and TPG, as well as 4D-MR-PCI of the
main pulmonary artery and the left atrium. Velocity fields resulting from 4D-MR-
PCI were visualised with dedicated software and evaluated for (1) the duration
of vortical blood flow (t
vortex) in the main pulmonary artery and (2) the left atrial
acceleration index a LA=2·vE/(vS+vD) determined from three-dimensional peak
velocities of systolic (v S) and diastolic (v D) pulmonary venous inflow and left
atrial outflow (v E). Relationships between invasively and non-invasively
determined parameters were analysed by correlation, linear regression and
Bland-Altman analysis.
Results
Strong correlations were found betw een mPAP and t
vortex (r=0.96) as
well as between PAWP and a LA (r=0.93). Linear regression equations
mPAP=15+0.66·tvortex and PAWP=-3+8·a LA (both in mmHg) estimated mPAP
and PAWP with standard deviations of 4 mmHg and 2 mmHg, respectively.
The difference of estimated mPAP and PAWP strongly correlated with TPG
(r=0.96) and resulted in a standard deviation of 4 mmHg between invasive and
non-invasive assessment.
Conclusion
4D-MR-PCI allows an accurate, non-invasive determination of the
hemodynamic key parameters mPAP, PAWP and TPG in patients with PH.
Author Disclosures:
G. Reiter: Employee; Siemens AG.
B-0498 15:12
4D flow and cardiac MRI to estimate pulmonary arterial pressure:
comparison with right-heart catheterisation in patients with pulmonary
hypertension
H. Ota, K. Sugimura, K. Nochioka, S. Tatebe, M. Miura, K. Satoh, K. Takase,
H. Shimokawa, S. Takahashi; Sendai/JP (
[email protected])
Purpose: Non-invasive method to estimate pulmonary artery (PA) pressure
remains to be developed. We examined whether several parameters driven by
4D flow and cardiac MRI parameters allowed the estimation.
Methods
and Materials: We enrolled 22 patients with pulmonary hypertension
(pulmonary arterial hypertension, 5, chronic thromboembolic pulmonary
hypertension, 17) and 4 normal volunteers for 4D flow and cardiac MRI. Using
4D flow MRI, the degree of vortex flow in the main PA flow was measured.
Cardiac MRI parameters, including, right ventricular ejection fraction (RVEF),
RV end-diastolic and end-systolic volume index, RV cardiac index, main PA
diameter, and ratio of main PA to ascending aorta diameter (ratio PA) were
documented. MRI findings were compared with catheter-driven mean PA
pressure (mPAP) in the 22 patients.
Results
Vortex flow in the main PA was observed in all patients, but not in the
volunteers. In the patients, the mean ± SD of mPAP and degree of vortex flow
were 37.6 ± 11.0 mmHg and 67.0 ± 9.4%, respectively. The degree of vortex
flow (Pearson's r=0.81, P < 0.01), ratio PA (r=0.51, P=0.02) and RVEF (r=-
0.44, P=0.04) was correlated with mPAP. Other parameters were not
correlated. Multivariate linear regression analysis demonstrated the degree of
vortex flow was significantly associated with mPAP (coefficient=12.5, 95%CI,
4.7, 20.2, P < 0.01) but the remaining parameters were not.
Conclusion
Among several MRI parameters, the degree of vortex flow in the
main PA demonstrated significant association with mPAP. 4D flow MRI was
useful to estimate mPAP in patients with pulmonary hypertension.
S242
BA C D E F G
Friday
B-0499 15:21
The prevalence of potentially serious incidental findings on cardiac MR
imaging: a systematic review
L.M. Gibson, L. Paul, C.L.M. Sudlow; Edinburgh/UK (
[email protected])
Purpose: To perform a systematic review to estimate the prevalence and
types of incidental findings on cardiac magnetic resonance (MR) imaging to
inform the design of the UK Biobank multi-modal imaging study of 100,000
middle-aged participants.
Methods
and Materials: We searched authors' files, Medline and Embase for
studies published in any language by June 2013 which reported the prevalence
of incidental findings on cardiac MR in adult patients or apparently healthy
volunteers. We defined serious incidental findings as those likely to threaten
lifespan, quality of life or major body functions. One reviewer selected studies
for inclusion and a second independently checked 10% of the references. We
extracted data on incidental findings, participant characteristics and imaging
variables.
Results
In 16 studies, 4,089 of 17,138 people (mean age 51 years, 42%
female, 22% patients) had incidental findi ngs, which were potentially serious in
699 (4.1%, 95% confidence interval 3.8-4.4%) including 415 suspected
malignancies. The commonest non-maligna nt potentially serious incidental
findings were pleural effusion (n=144), non-specific major parenchymal lung
abnormality (n=23) and pulmonary consolidation (n=17). Potentially serious
incidental findings were detected more frequently in studies using contrast
compared to non-contrast imaging (5.6% versus 1.5%). One study (n=132)
used a 3 T scanner, and the remainder used 1.5 T scanners.
Conclusion
Potentially serious incidental findings are common on cardiac
MR. Over half are suspected malignancies. The potential for such findings
should be discussed with research participants and patients when seeking
informed consent. Investigators should design systems for evaluating
incidental findings and referring patients to healthcare providers.
Author Disclosures:
L.M. Gibson: Research/Grant Support; Received funding from UK Biobank to
attend educational meetings. C.L.M. Sudlow: Other; UK Biobank Chief
Scientist.
14:00 - 15:30 Conf. Room M3
Interventional Radiology
SS 609
Trends in occlusive and aneurysmal
disease
Moderators:
E. Dosa; Budapest/HU
D.K. Tsetis; Iraklion/GR
B-0500 14:00
The effect of sustained delivery of sirolimus on neointimal hyperplasia
and the local thrombotic environment after angioplasty
Y. E
1, N. He2; 1Baoding/CN, 2Tianjin/CN (
[email protected])
Purpose: To explore the effect and potential problems of local sustained
delivery of sirolimus for restenosis prevention after PTA.
Methods
and Materials: Experimental common carotid artery injury model
was established in the rat. Pluronic F-127 gel containing sirolimus was applied
to the exposed adventitial surface of the injured carotid artery, and the effects
of local sustained delivery of sirolimus for restenosis prevention after
angioplasty were evaluated by haematoxylin and eosin staining and
immunohistochemistry staining.
Results
15 and 30 days after injury, compared to controls the neointimal
thickness and area, the ratio of intimal area to medial area and the stenotic
rate were significantly decreased in both high concentration (600 8g/100 8l)
and low concentration (300 8g/100 8l) experimental groups ( P
< 0.01);
Compared to controls, 15 and 30 days after injury local sustained delivery of
sirolimus in both experimental groups enhanced the expression of the TF and
PAI-1 in neointima (P
< 0.05), however, the expression of t-PA in neointima
was decreased in both high and low concentration groups ( P < 0.05).
Conclusion
Local sustained delivery of sirolimus not only suppressed the
neointimal hyperplasia effectively, but also induced the high expression of TF
and PAI-1 and low expression of t-PA in neointima, and the imbalance
expression of TF, tPA and PAI-1 could play an important role in late thrombosis
formation after DES (drug eluting stent) placement.
B-0501 14:09
Calcium assessment and impact on drug eluting balloons in peripheral
arterial disease
F. Fanelli, A. Cannavale, M. Corona, P. Lucatelli, A. d'Adamo, A. Wlderk,
F.M. Salvatori; Rome/IT (
[email protected])
Purpose: To assess the effect of calcium on the efficacy of DEB during
revascularisation of steno-obstructive SFA lesions.
Methods
and Materials: Sixty patients with de-novo lesions of the superficial
femoral artery (SFA) underwent endovascular treatment with DEB. A pre-
dilatation with conventional undersized (- 1 mm RVD) angioplasty balloon was
done. DEB were selected according to vessel reference diameter (1:1) and
keep inflated for 60 seconds. In case of residual stenosis > 50% or flow-limiting
dissection a post-dilatation with conventional balloon or provisional stenting
was done. Ankle-brachial index (ABI), late lumen loss (LLL), target lesion
revascularisation (TLR), primary (PP) and secondary (SP) patency, major
adverse events (MAE) and Rutheford shift were evaluated after a minimum
follow-up of 1 year. Patients were divided in eight groups according to the
amount of calcium: degree from 0° to 360°; length 3 cm.
Results
Recanalisation was done success fully in all cases. Flow-limiting
dissection occurred in 5 cases (8.3%) with higher degree of calcium. It was
solved with post dilatation in 3 cases and provisional stenting in the other 2. A
less effect of DEB was observed in those patients with higher degree of
calcium ( > 270° vs. < 90°): ABI 0.71 ±0.07 vs. 0.92± 0.07; LLL 0.75 ±0.21 vs.
0.45±0.10; PP 50% vs. 100%; SP 50% vs. 100%; TLR 25% vs. 0%; MAE 25%
vs. 0%. According to the length of calcium, results were similar.
Conclusion
Calcium represents a barrier for optimal drug absorption.
Circumferencial distribution seems to be the most influencing factor with worst
effect noted in 360° calcium presence.
B-0502 14:18
Efficacy of drug eluting balloon percutaneous transluminal angioplasty to
treat recurrent carotid in-stent restenosis: long-term results
C. Del Giudice, R. Gandini, V. Da Ros, S. Altobelli, E. Salvatori, E. Pampana,
G. Simonetti; Rome/IT (
[email protected])
Purpose: To evaluate the potential role, safety and efficacy of drug eluting
balloon for treatment of carotid in-stent restenosis (ISR).
Methods
and Materials: 856 consecutive patients underwent carotid artery
stenting from May 2002 to January 2008. In 41 patients a significant ISR
(> 80% stenosis) occurred. Nine of these were affected by the onset of
recurrent restenosis after multiple treatments within a short period of time.
These patients were treated with DEB angioplasty to treat internal carotid
artery ISR. An ultrasound controlwas performed at 1, 3, 6 and yearly after the
procedure with mean follow-up time 36.6 ±2.7 months.
Results
A technical success was obtained in 100% of cases. A distal filter
device was used in all cases. No major periprocedural neurological or
myocardial events were recorded. Angiographic stenosis decreased from
87%±4% to 6± 4%. Peak systolic velocity (PSV) decreased significantly after
the procedure from 4.7 ±1.5 to 1.3±0.5 m/s. PSV maintained under a significant
values during the follow-up except in one patient, who developed a significant
ISR 3 years after the procedure. TVR was 9% at 36 months follow-up. No
neurological or myocardial events were recorded during the follow-up. 1 patient
died at 3 months follow-up.
Conclusion
DEB may have a potential role, improving outcomes of patients
treated for carotid ISR.
B-0503 14:27
An echo-color-doppler analysis - carotid endarterectomy vs stenting:
does the flow really change?
P. Lucatelli1, F. Fanelli1, A. Cannavale1, C. Cirelli1, M. Corona1, A. d'Adamo1,
C. Catalano1, F.M. Salvatori1, L. Saba2; 1Rome/IT, 2Cagliari/IT
(
[email protected])
Purpose: To assess potential hemodynamic differences after Carotid
EndArterectomy (CEA) and Carotid Artery Stenting (CAS) and their eventual
impact on clinical management.
Methods
and Materials: Between 2010 and 2011 two groups of 30 patients
referred for CAS or CEA were prospectively enrolled. Pre-procedural imaging
was performed with ECD and CTA. ECD was repeated within 24 hours, at one,
six and twelve months from the procedures. PSV and EDV were assessed at 2
standard site: CCA and distal ICA.
Results
Twenty-four hours findings highly differs between populations.CCA
PSV in the CEA and CAS group were respectively 44.88 ±9.16 cm/sec and
69.20±20.04 cm/sec (p= 0.002);CCA EDV were 16.11± 2.29 cm/sec and
19.13±6.42 cm/sec (p=0.065);ICA PSV were 46.11 ±7.9 cm/sec and
94.02±57.7 cm/sec (p=0.0012);ICA EDV were 20.22 ±4.33 cm/sec and
30.47±18.33 cm/sec (p= 0.025).One month, six months and one year follow-up
confirmed the different trend in the findings of two cohorts; in particular at one
year:CCA PSV were 50.94 ±12.44 cm/sec and 60.59 ±26.84 cm/sec (p=
S243
BA C D E F G
Friday
0.181);CCA EDV were 17.11± 3.46 cm/sec and 19 ±16.35 cm/sec
(p=0.634);ICA PSV were 51.66 ± 10.1 cm/sec and 70.86 ± 20.64 cm/sec
(p=0.014);ICA EDV were 25.05 ±8.65 cm/sec and 32.66± 13 cm/sec (p=
0.0609).
Conclusion
ECD follow-up is mandatory for these patients, allows to reduce
false positive re-stenosis diagnosis, to choose the best anti-aggregation
therapies. Within the first month from CEA patient benefits of a lower risk
condition compared to CAS patient, due to a significant faster drop of the PSV;
moreover long-term CEA CCA PSV could be used as a surrogate marker of
neointima formation.
B-0504 14:36
Paclitaxel-coated balloon-angioplasty for central-venous re-stenosis in
patients with haemodialysis fistulas
A. Massmann
1, P. Fries1, K. Obst-Gleditsch1, R. Shayesteh-Kheslat1,
M. Katoh2, A. Buecker1; 1Homburg a.d. Saar/DE,
2Krefeld/DE (
[email protected])
Purpose: Retrospective evaluation of standard (POBA) and Paclitaxel-coated
balloon angioplasty (PCBA) for central venous re-stenoses in patients with
impaired haemodialysis fistulas.
Methods
and Materials: 27 patients (male 15, female 12, mean 66 ±14 [39-90]
years) with 32 non-malignant central venous stenoses confirmed by
sonography, MRI or venography were treated initially by POBA. In case of
symptomatic re-stenoses re-intervention was done by POBA in 5 patients of
whom 2 patients underwent 11 or 5 POBA treatments. PCBA was performed in
13 patients after single or repetitive POBA. All Paclitaxel-coated balloons
(Elutax SV, AachenResonance, Germany) (diameter 6-14 mm) were custom-
made.
Results
Central venous stenosis included the axillary (11), subclavian (6),
brachiocephalic (12) and/or superior caval vein (3). 3 patients had a
combination of 2, 1 patient of 3 central venous stenoses. Overall primary
technical (residual stenosis < 30%) and clinical (shunt function) success of
initial and re-angioplasty was 100%. Re-interventions (POBA n=32; PCBA
n=20) due to re-stenosis were necessary in 15 (55.6%) patients. Kaplan-Meier
analysis revealed PCBA significantly superior to POBA. Median freedom from
TLR after PCBA was 12 months vs. 5 months after POBA (p=0.03; Log-rank
(Mantel-Cox), Gehan-Breslow-Wilcoxon test). Re-re-stenosis intervals were
significantly prolonged by PCBA (mean 9.5 ±1.9 months) vs. POBA (mean
5±4.9 months) (p=0.01; unpaired t-test). No minor/major procedure-associated
complications occurred.
Conclusion
Paclitaxel-coated balloon-angioplasty of central-venous re-
stenosis yields a significantly longer freedom from TLR in patients with
haemodialysis shunts and therefore should be the primary treatment approach.
B-0505 14:45
Paclitaxel-coated balloons vs. plain balloon angioplasty for the failing
fistula: final 1-year results of the randomised controlled trial
P.M. Kitrou
1, S. Spiliopoulos1, K. Katsanos2, M. Kyriakopoulou1,
D. Karnabatidis1, D. Siablis1; 1Patras/GR, 2London/UK
(
[email protected])
Purpose: /o report the final 1-year results of a prospective randomised
controlled trial investigating paclitaxel-coated balloon (PCB) vs. plain balloon
(PB) angioplasty for the treatment of failing arterio-venous fistulae (AVF).
Methods
and Materials: From May 2011 to September 2012, 40 patients were
randomised to undergo either PCB dilation (Group PCB, n=20) or PBA (Group
PB, n=20). Enrollment criteria included a clinical and angiographic diagnosis of
dysfunctional AVF circuit due to at least one stenotic lesion. Regular
angiographic follow-up was scheduled every 2 months. Study primary
endpoints included technical success (defined as residual stenosis of the
treated lesion < 30% without any significant dissection) and primary patency of
the treated site (defined as angiographic visualisation of a patent lesion with
< 50% restenosis and no need for any additional repeat procedure within the
previously treated lesion due to failing access).
Results
Baseline variables were equally distributed among the two groups.
Technical success was 100% for both the groups. Interim calculation of the
primary endpoint outcome showed a significantly superior primary patency in
group PCB compared to group PB at 6 months (65.0% vs. 30%, respectively;
p=0.04).
Conclusion
Six-month interim results show that PCB angioplasty could be a
valid solution in to our armamentarium for the treatment of failing AVF. Long-
term 1-year final data will be announced.
B-0506 14:54
Single center prospective randomised study to evaluate treatment of
superficial femoral artery chronic in-stent occlusion with combined laser
atherectomy and drug eluting balloon angioplasty in patients with critical
limb ischemia
C. Del Giudice, R. Gandini, S. Merolla, D. Morosetti, E. Pampana,
G. Simonetti; Rome/IT (
[email protected])
Purpose: To compare efficacy and safety of laser debulking (LD) and drug
eluting balloon (DEB) angioplasty to treatment with DEB angioplasty alone in
patients affected by critical limb ischemia (CLI) and superficial femoral artery
(SFA) chronic stent occlusion.
Methods
and Materials: From December 2009 to March 2011, 48 patients (of
448 CLI patients)underwent endovascular treatment of a SFA chronic stent
occlusion. The patients were randomly sub divided in two groups: LD combined
with DEB angioplasty was used in 24 patients (Group 1) and 24 patients were
treated with DEB angioplasty alone (Group 2). The patency rate at 12 months
follow-up was the primary endpoint. Secondary endpoints were target lesion
revascularisation (TLR) and clinical success at 12 months follow-up.
Results
In Group 1, the patency rate was significantly higher than in Group 2
at 6 and 12 months follow-up (respectively 91.7% and 66.7% in group 1 and
58.3% and 37.5% in group 2, p=0.01). TLR at 12 months follow-up was 16.7%
in group 1 and 50% in group 2 (p=0.01). Two patients (8.3%) needed major
amputations in group 1 while 11 patients (45.8%) in group 2 at 12 months
follow-up (p=0.003).
Conclusion
The combined treatment with LD and DEB angioplasty is
correlated with better outcomes in CLI patients with SFA stent occlusions.
B-0507 15:03
Evaluation of local thrombolysis for thrombosis of total implantable
venous access devices (port-systems)
A. Massmann, M. Wolska-Krawczyk, T. Probst, P. Minko, G.K. Schneider,
A. Buecker; Homburg a.d. Saar/DE (
[email protected])
Purpose: Evaluation of local thrombolysis for thrombosis of total implantable
venous access devices (venous port-systems).
Methods
and Materials: 101 patients (15-81 years) with port-dysfunction were
referred for angiography. Thrombosis of the port-catheter was treated by local
thrombolysis with injection of 3-5 mg rt-PA directly into the port system. Port
function was re-evaluated by re-angiography the next working day.
Results
Port-dysfunction was obvious due to impossible blood aspiration in
59 ports. Injection of saline solution was impossible or only with unusual high
pressure achievable in 41 ports. 3 patients reported local pain during injection.
Angiography depicted port-catheter thrombosis in 46 ports. 41 patients agreed
to a local thrombolysis treatment. Re-angiography on the next working day
(time interval 16 hours-3 days) confirmed a successful procedure in 37 (90%)
patients. 5 ports showed residual thrombosis but working port-function. Re-
thrombosis occurred in 3 patients after 5 days (n=1) and 3 months (n=2).
Unsuccessful thrombolysis was observed in 4 patients with extensive
thrombosis extending into the subclavian and jugular veins. Complete
dislocation or disruption with consec utive malfunction of the TIVAD was
detected in 15 (15%) patients. 4 TIVAD-catheters dislocated into the vena cava
or right heart and were successfully retrieved. 17 mal-functioning ports showed
misplaced catheter-tips. 16 were corrected interventionally yielding complete
restored port function. No patient was referred for a second repositioning.
Conclusion
Port-catheter thrombosis related dysfunction can easily and
safely treated by local thrombolysis.
B-0508 15:12
Incidence and management of visceral artery aneurysms (VAA)
M.B. Pitton, E. Dappa, R. Kloeckner, S. Schotten, G.M. Wirth, A. Lollert,
F. Jungmann, J. Doering, C. Dueber;
Mainz/DE (
[email protected])
Purpose: Visceral artery aneurysms (VAA) are rare but imply an risk for acute
rupture. We analysed the institutional data base for diagnosis and
management of VAA over a period of 10 years.
Methods
and Materials: 239 patients were identified suffering from VAA. VAA
were analysed with respect to location, size, true aneurysm or false aneurysms
after surgery/intervention, rupture status, management, and clinical follow-up.
Results
VAA were located in splenic artery (n=81), celiac trunk (n=46), renal
artery (n=42), hepatic artery (n=37), superior mesenteric artery (n=15),
gastroduodenal artery (n=10) and others (8). Mean follow-up was 42.9 ±34.9
months. 181 of 239 patients were monitored conservatively. 58 cases were
treated with transarterial intervention (n=47, embolisation, stentgrafting, or
combinations) or surgery (n=11), 40 patients were diagnosed at rupture and
were treated on an emergency basis. There was no significant difference in
size between ruptured and non-ruptured VAA (15.2 ± 8.4 mm vs.
16.3 ± 10.1 mm). The 30-day mortality in ruptured cases was 8.3% after S244
BA C D E F G
Friday
interventional treatment compared to 0% in elective cases. Conservatively
treated patients presented a 30-day mortality of 6.1%.
Conclusion
The clinical impact of VAA remains unclear. There was no
difference in size in ruptured and non-ruptured aneurysms. Interventional
treatment seems to offer a beneficial approach compared to surgery.
B-0509 15:21
Single-center experience in endovascular treatment of visceral artery
aneurysms and pseudoaneurysms with Viabahn covered stent: technical
aspects, success rate, complications and MDCT follow-up
M. Orsi, M. Venturini, F. Morelli, M. Colombo, C. Sallemi, F. De Cobelli,
M. Salvioni, S. Cappio, A. Del Maschio; Milan/IT (
[email protected])
Purpose: To report our single-center experience in endovascular treatment of
visceral artery aneurysms/pseudoaneurysms with Viabahn covered stent.
Methods
and Materials: From 2005 to 2013, 13 patients were treated with 16
self-expandable covered stents (Viabahn, Gore; diameter from 5 to 8 mm;
length from 2.5 to 5 cm): 11 in the hepatic artery, 4 in the splenic artery, 1 in
the renal artery. 6/13 patients were trea ted for aneurysms (3 splenic, 2 hepatic,
1 renal); 7/13 for post-surgical bleeding pseudoaneurysms (5 of the
gastroduodenal artery, 1 of hepatic artery, 1 of the splenic artery). A
transfemoral approach was performed in 11/13, left-transaxillary in 2/13 due to
the unfavourable angle of the celiac trunk. Double antiplatelet therapy was
administered for 6 months after stent placement. A triphasic contrast-enhanced
MDCT was performed before, 1 day and 6 months after the procedure.
Results
All covered stents were properly placed in their targeted vessels.
Successful treatment without complications was achieved in 10/13 patients. In
3/13 patients, complications were recorded: 1 post-stenting stenosis of the
proper hepatic artery, resolved with PTA; 1 stent occlusion in the common
hepatic artery, without liver ischaemia because of the blood supply from the
gastroduodenal artery; 1 minimal splenic infarction after stent placement in the
splenic artery without clinical consequences. At 6 months, MDCT showed stent
patency in 12/13 cases.
Conclusion
Endovascular treatment of visceral aneurysms/pseudoaneurysms
using a very flexible, self-expandable, Viabahn covered stent represents an
effective, less invasive, more conservati ve alternative to surgery/embolisation.
14:00 - 15:30 Board Room A
Cardiac
SS 603b
Congenital heart disease and cardiac
masses
Moderators:
J. Glowacki; Zabrze/PL
M. Kantarci; Erzurum/TR
B-0510 14:00
Right ventricular myocardial fibrosis detection using cardiac MR in
repaired tetralogy of fallot: correlation between functional and clinical
markers
N. Galea, V. Noce, V. Sorrentino, M. Francone, C. Catalano, I. Carbone;
Rome/IT (
[email protected])
Purpose: To assess correlations between right ventricular myocardial fibrosis,
detected by late gadolinium enhancement (LE) on cardiac magnetic resonance
(CMR), bi-ventricular function and clinical data after surgical correction of
tetralogy of fallot (rToF).
Methods
and Materials: Study population included a retrospective selection of
15 patients with rToF undergone to a complete CMR assessment including:
cineMR steady-state free precession (SSFP) sequences to assess bi-
ventricular volumes, myocardial mass and peak filling/ejection rates, T2 STIR
sequences and T1-weighted inversion-recovery images after 0.1 mmol/kg Gd-
BOPTA injection to detect right ventricular late enhancement (RVLE). A clinical
dataset at the time of CMR scan was built up for each patient, including NYHA
class, exercise tolerance, history of arrhythmias and syncope.
Results
9/15 patients presented RVLE, localised at RV insertions points (7/9)
and amongst RV trabeculations (2/9). On the basis of RVLE finding, we divided
our cohort into positive and negative grou ps for statistical analysis (difference
between means assessed with student's t test independent sample, correlation
assessed with Spearman/Pearson analyses). We determined that RVLE
presence correlates with reduction of RV ejection fraction (47.2 ±5.6%,
p < 0.001) and end-systolic volume index increases (57.3 ±7.2 ml/m2,
p < 0.001). Moreover, a negative correlation was found between RVLE
presence and both NYHA class and exercise tolerance (mean exercise
duration 778±47 min, p < 0.001).
Conclusion
Our study exposed a high prevalence of RVLE in rToF patients,
determined by LGE CMR. RVLE presence was correlated to RV functional
decline and clinical deterioration. No correlation between RVLE and left
ventricular function parameters was showed.
B-0511 14:09
Diagnostic value of dual source CT angiography in congenital heart
diseases: comparison with transthoracic echocardiography and
angiography
M.A. Karimi, F. Sedaghat, M. Motevalli, H. Pouraliakbar; Tehran/IR
(
[email protected])
Purpose: Dual-source CT angiography (DSCTA) is a new imaging method
with high spatial and temporal resolutions that provides valuable information
about detailed structures of heart. The aim of this study was to determine
diagnostic value of DSCTA in cardiac diseases.
Methods
and Materials: Parameters of diagnostic value (sensitivity,
specificity, positive predict ive value [PPV], negative predictive value [NPV] and
diagnostic accuracy) of DSCTA were determined in 36 patients with congenital
heart diseases (median:8.5 month [neonate to 35 y]; 21 male) who underwent
surgery in Shahid Rajaei Hospital from September 2010 to March 2011, and
compared with that of angiography and transthoracic echocardiography (TTE).
Surgery was gold standard.
Results
Total 105 cardiac anomalies were diagnosed. Sensitivity, specificity,
PPV, NPV and accuracy of DSCTA were 98.25%, 97.9%, 98.1%, 99.07%, and
98.2%, respectively. These values were 95.04%, 98.7%, 97.8%, 98.1%, and
98%, respectively, for angiography, and 93.5%, 96.2%, 94.4%, 96.3%, and
95.4%, respectively, for TTE. There was no statistically significant difference
between three methods. Only, one ASD and 2 PDA were missed in DSCTA.
Angiography missed 2 ASD and 2 PDA, and TTE missed 7 ASD, one VSD,
and 3 PDA. DSCTA also provided important findings (n=38) about intrathoracic
or abdominal organs.
Conclusion
DSCTA has a diagnostic value similar to angiography for
congenital heart diseases and can obviate the need for invasive diagnostic
modalities. DSCTA also can provide important information about detailed
anatomic structures of heart, vessels, lungs and intra-abdominal organs.
B-0512 14:18
The relationship of location of patent foramen ovale with severity of
stroke: a life-saving radiological approach
M.F. Erkoç
1, Ö. Örsçelik1, B. Öztoprak1, A. Okur2, M. Kantarcı3, Y. Kızrak3;
1Yüceyurt/TR, 2Yozgat/TR, 3Erzurum/TR (
[email protected])
Purpose: Patent foramen ovale (PFO), is a common developmental anomaly
that causes paradoxical embolus and may be found in approximately 25% of
adults. In literature, PFO and stroke is well associated as PFO causes for up to
40% of all ischaemic strokes. However, percutaneous closure of PFO for the
patients with/without stroke is controversial. The aim of this study is to
investigate the relationship of the location of PFO with severity of stroke and to
help identify the patients who would benefit from percutaneous PFO closure
before ischaemic stroke appears; which is vital.
Methods
and Materials: 17 patients with stroke and echocardiographically
proven PFO were classified according to the severity of stroke by cranial MRI;
and the locations of PFO were determined as superior and inferior based on an
imaginary line that separates the interatrial septum into two equal parts by
cardiac CT. Paired statistical analysis was applied.
Results
4 patients (47%) revealed mild, 5 patients (30%) severe and 8
patients (23%) moderate according to their severity of stroke. Based on the
PFO locations, there were 13 (77%) patients with superiorly (group I), and 4
patients (23%) with inferiorly located PFO (group II). Statistically, there was a
strong correlation between the patients presenting with moderate and severe
stroke with group.i. (p < 0.005).
Conclusion
Superiorly located PFO patients have a greater risk for stroke
and may face different neurological problems in their rest of life, percutaneous
closure of superiorly located PFOs when detected will provide a life-saving
process.
B-0513 14:27
Two methods for quantification of cardiovascular shunts by cardiac
magnetic resonance (CMR) in patients with atrial septum defects (ASD)
E. Pershina, M.A. Glazkova, E. Mershina, V.E. Sinitsyn; Moscow/RU
(
[email protected])
Purpose: To compare velocity-encoded phase-contrast (VENC) MRI and
volumetric analysis of shot-axis imag es for quantification of cardiovascular
shunts in patients with atrial septum defect (ASD).
Methods
and Materials: 31 patients (16/15-f/m, mean age 36, 7± 16, 7 years)
with ASD underwent 1, 5 CMR to determine the size and localisation defects,
to quantify shunts between systemic (Q s) and pulmonary (Qp) circulation. 25
S245
BA C D E F G
Friday
patients had ostium secundum defects (11 of them - small multiple defects), 5
sinus venosus and 1 ostium primum defect. A typical CMR protocol included
long- and short-axis cine steady-state free-precession images and VENC
images. VENC images acquired perpendicular to the ascending aorta and
main pulmonary artery for measuring Qs and Qp. Using volumetric analysis,
shunt volume and shunt fraction were calculated as the difference between left
ventricle and right ventricle stroke volumes (SV). Semiautomatic
postprocessing was used for calculating Qp:Qs with both methods.
Results
The ratio Qp:Qs ranged from 1:1.1 to 1:4 (mean 2.1 ±0.96). Patients
with Qs:Qp > 1.5 were recommended for cardiac surgery consultation.
Correlation between Qp:Qs mesuared with VENC and SV difference was very
strong (p=0.99). In small left-to-right shunts (Qp:Qs 2.0), right atrial and right
ventriculars volumes were increased and signs of pulmonary hypertension
were found.
Conclusion
Volumetric analysis of short-axis images could be an alternative
to VENC method for quantification of cardiovascular shunts in patients with
ASD.
B-0514 14:36
Role of 256-MDCT in evaluation of image quality and radiation dose in
prospective gating in congenital heart diseases in infants
A.K. Sharma; Delhi/IN (
[email protected])
Purpose: To evaluate image quality and radiation dose in prospectively ECG
gated 256 Slice MDCT angiography in infants with congenital heart diseases.
Methods
and Materials: From May 2011 to May 2013, 60 infants with
congenital heart disease referred for pre-operative or post-operative CT were
included. All were scanned with 256 MDCT Somtom Definition Flash Siemens
Dual source Unit utilising a low dose protocol.
Results
No serious reactions noted. A total 184 cardiac anomalies were
confirmed by surgery or heart catheteri sation.The sensitivity of MDCT for
cardiac anomalies was 97.1%, specificity 98.4%, and accuracy 95.2%. The
mean heart rate during scan was 126/min. Mean scan length was 115.3 mm.
Mean volume CT dose was 2.1mGY. Diagnostic quality images were obtained
and viewed by two radiologists independently.
Conclusion
Low dose prospectively gated CT in infants with CHD is the ideal
modality with comprehensive 3D evaluation including coronary arteries with
minimal mean volume CT dose.
B-0515 14:45
Delayed myocardial enhancement in pediatric idiopathic hypertrophic
cardiomyopathy
N.H. Behairy, W. El Mozy; Cairo/EG (
[email protected])
Purpose: To detect the presence of myocardial fibrosis in paediatric age group
and whether there is a certain age of which fibrosis may be suspected.
Methods
and Materials: We prospectively studied 20 patients diagnosed as
idiopathic hypertrophic cardiomyopathy clinically and by echocardiography as
well as laboratory methods. Patients were between 1.5 yrs up to 16 years. All
patients were subjected to MRI and echocardiography. MRI was performed on
(ACHIEVA, 1.5 T Philips Medical Systems,Netherlands). Balanced FFE in 2, 4
chambers as well as short axis images were taken in 20 cardiac phases along
with delayed enhancement after 5-10 min with triple inversion recovery after
performing look locker to determine the best time of delay. Q flow was done to
detect the presence of obstruction at the aortic valve region. Images were
analysed for volumetric measurements, functional analysis and myocardial
tissue characterisation. The presence, pattern and site of ventricular
enhancement were studied.
Results
Fifteen patients (75%) showed presence of patchy midwall
myocardial enhancement. 25% of patients did not show any enhancement.
Some of the patients with evident myocardial enhancement were as small as
1.5 years. Myocardial thickness ranged from 15 to 24 mm. Enhancement was
present in the area of most hypertrophy. Ejection fraction ranged from 55 to
72%.
Conclusion
Myocardial fibrosis may be present in paediatric hypertrophic
cardiomyopathy with no cut-off value for age.
B-0516 14:54
Detection and characterisation of myocardial fatty foci in patients
affected by tuberous sclerosis complex using high-resolution computed
tomography: a new diagnostic criteria?
S. Tresoldi, P. Magistrelli, G. Pompili, L. Rahali, G. Cornalba; Milan/IT
(
[email protected])
Purpose: To evaluate prevalence and characteristics of MFF in TSC patients
undergoing HRCT.
Methods
and Materials: All consecutive TSC patients who underwent 64-slice
HRCT (1.25x1.25 mm) for suspected lymphangioleiomyomatosis (LAM)
between January 2010 and August 2013 were retrospectively selected. Image
evaluation was performed (in double blind trial) by two radiologists with
different experience in cardiac imaging using both axial and multiplanar
reformation (MPR) images even on cardiac axis (short axis, long axis and 4-
chamber view) to detect MFF (well-circumscribed areas with homogeneous fat
CT density within the myocardium). MFF presence, number, site, size and
shape were evaluated. In doubtful cases (e.g. artefacts due to hearth
pulsation), the patient was considered free of foci. Information about other
organs involvement (brain; kidneys; liver; lung) were obtained. Descriptive
statistics were used and correlation between MFF and other organs'
involvement was estimated.
Results
Study population resulted composed of 39 patients (35 females;
mean age 34.5 years; range 18-52 years). MFF were identified in 51.3%
(20/39) of patients 7 of whom (35%) had TSC multiorgan involvement. MFF
were more often linear and identified more frequently in the apical
interventricular septum; MFF size range was 8-50 mm. Other organ
involvement was as follows: kidneys 84.6% (33/36) of patients; lung 79.4%
(31/39); brain 66.6% (26/39), liver 46.1% (18/39). Only 2 patients with
multiorgan involvement had no MFF.
Conclusion
Prevalence of MFF in TSC patients is high and it is often
associated to other organ involvement
B-0517 15:03
Isolated left ventricular non-compaction: relationship between MRI
criteria for non-compaction and clinical events
K. Warin-Fresse, D. Marrest, L. Le gloan, C. Defrance, B. Delasalle, M. Caza,
P. Guerin; Nantes/FR
Purpose: Isolated ventricular non-compaction (LVNC) is characterised by a
compacted epicardial band and a non-compacted endocardial layer.
Complications are ventricular dysfunction, arrhythmias and thromboembolic
events. The aim of the study was to look for a potential relationship between
MRI's non-compaction extension criteria and clinical events.
Methods
and Materials: Between 2004 and 2013, 99 patients were included
in a retrospective study reviewing MRI with LVNC. MRI diagnosis criteria for
LVNC was the ratio of the thickness of non-compacted (NC) to compacted
myocardial layers superior to 2.3, in the diastolic phase. LV ejection fraction,
volumes, global LV mass, compacted and NC LV mass, number of NC
segments and non-compaction score (NCS) were measured. A LV remodelling
index (LVRI) defined as the ratio between LV compacted mass and LV end-
diastolic volume was calculated.
Results
There were no statistical relationships between LVEF alteration and
NCS (p=0.57) and the number of NC segments (p =0.97), between stroke
incidence and NCS (p=0.22) and the number of NC segments (p=0.96) and
between ventricular arrhythmias and NCS (p=0.59) and the number of NC
segments (p=0.59). There was a significant inverse relation between LVEF and
compacted mass (p < 0.0001) and between stroke and compacted mass (p =
0.007), but not for ventricular arrhythmias (p = 0.95). There was no statistical
relationship between LVRI and LVEF, arrhythmias or stroke.
Conclusion
This study did not show any association between MRI NC
extension criteria and clinical events, but showed a relationship between
compacted mass and LVEF dysfunction and stroke incidence.
B-0518 15:12
Differences in CMR characteristics between pulmonary hypertension
associated to congenital heart disease and other precapillary pulmonary
arterial hypertension subgroups
S.-A. Mouratoglou
1, A. Kallifatidis1, G. Giannakoulas1, V. Kamperidis1,
I. Grapsa2, G. Pitsiou1, I. Stanopoulos1, S. Hadjimiltiades1, H. Karvounis1;
1Thessaloniki/GR, 2London/GR (
[email protected])
Purpose: To compare CMR parameters between patients with pulmonary
arterial hypertension associated to congenital heart disease (CHD-PAH) with
those of patients classified in the rest of precapillary pulmonary arterial
hypertension subgroups (pPAH).
Methods
and Materials: All patients underwent cardiac magnetic resonance
(CMR),(Siemens Avanto 1.5T) for the determination of right ventricular (RV)
function and pressure overload and echocardiographic study for the
assessment of tricuspid annular plane systo lic excursion (TAPSE) on the same
day.
Results
Our study included 6 patients with CHD-PAH (mean age
40.3±13.9years) and 8 with pPAH (mean age 51.4 ±11.5years). Patients in both
study groups retained mildly reduced but similar RV function, as expressed by
TAPSE (1.7 ±0.2 cm in CHD-PAH and 1.8 ±0.3 cm in pPAH, p > 0.05) and RV
ejection fraction (46.8 ±10.9% in CHD-PAH and 48.2 ±11.6% in pPAH, p> 0.05),
although CHD-PAH patients had higher RV diastolic pressure overload (as
expressed through RV eccentricity index in diastole: 2.3 ±0.3 and 1.7 ±0.2
respectively, p=0.002). Pulmonary artery (PA) was more severely dilated in
CHD-PAH than in pPAH [as expressed by PA diameter in systole (5.1 ±0.5 cm
S246
BA C D E F G
Friday
and 4.2± 0.5 cm, p=0.01) and in diastole (4.9 ±0.5 cm and 4.0 ±0.5 cm,
p=0.009)].
Conclusion
Although patients with CHD-PAH have more severely pressure
overloaded right ventricle, they manage to retain similar RV function when
compared to pPAH patients. This may reflect the progressive RV adaptation to
chronic increase of RV blood flow and pressure occurring before the
development of elevated pulmonary vascular resistance and fixed PAH. PA
dilatation is another compensatory mechanism in CHD-PAH patients and may
explain their greater risk of in situ thrombosis.
B-0519 15:21
Intracardiac thrombus and masses in patients with CAD: CMR versus
TTE
W. Staab
1, L. Bergau1, M. Dorenkamp2, S. Obenauer3, R. Hinojar4, J. Lotz1,
C. Sohns1; 1Göttingen/DE, 2Berlin/DE, 3Düsseldorf/DE, 4London/UK
(
[email protected])
Purpose: Transthoracic echocardiography (TTE) is widely used for patients
with coronary artery disease (CAD) and suspected intracardiac mass. This
study aimed to assess the current role of cardiac MRI (CMR) to differentiate
cardiac masses from thrombus formation in comparison to TTE.
Methods
and Materials: 171 patients (89 male, aged 34-89 years, median
60.8±10.7) with known CAD who had been referred to TTE for evaluation of
known or suspected intracardiac mass, underwent additional 1.5-Tesla CMR.
TTE and CMR were independently evaluated for thrombus formation or
intracardiac mass and related size, shape, signal characteristics and
morphology.
Results
TTE depicted intracavitary thrombus formation in 40/171 patients
(23.4%) and intracardiac mass in 12/171 patients (7.0%). All masses detected
in TTE were correctly seen on CMR. However, CMR showed 15 subsequent
thrombi and 3 additional intracardiac masses (p= 0.001) that were not detected
in TTE. Patients with impaired systolic function (LVEF < 30%) showed
misleading results when referred to TTE (19 vs. 27 masses detected, p < 0.01).
Conclusion
TTE depicted intracavitary thrombus formation in 40/171 patients
(23.4%) and intracardiac mass in 12/171 patients (7.0%). All masses detected
in TTE were correctly seen on CMR. However, CMR showed 15 subsequent
thrombi and 3 additional intracardiac masses (p= 0.001) that were not detected
in TTE. Patients with impaired systolic function (LVEF < 30%) showed
misleading results when referred to TTE (19 vs. 27 masses detected, p < 0.01).
B-0520 15:30
The application of dual source CT in complex congenital heart disease of
tetralogy of Fallot
S. Ou, F. Long, S. Ou, K. Cai, B. Li, G. Qiao; Guangzhou/CN
(
[email protected])
Purpose: To investigate the clinical value and accuracy of DSCT in the
assessment of patients with Tetralogy of Fallot (TOF).
Methods
and Materials: 70 patients suspected or known complex congenital
heart disease of tetralogy of Fallot underwent DSCT. A combination of
restruction with images of end-systole, including maximum intensify projection,
multi-planar reconstruction, volume rendering, and so on. Seek the
cardiovascular malformation according to the Van Praagh Segment analytical
method. Two radiologists with 5 years expe rience in the field of cardiovascular
imaging diagnosis assessed the imagi ng. The DSCT imaging diagnosis was
compared with echocardiography (ECHO) or operation results. Analyse the
accuracy of DSCT and the ECHO results compared with surgery. Descriptive
statistics was used to compare efficacy.
Results
51 patients had surgery in all 70 patients. 255 places of malformation
were proved by operation, including 91 intracardiac malformations and 164
extracardiac malformation.
The diagnostic accuracy of intracardiac
malformations were 94.5% (86/91) and 97.8%(88/91) respectively by DSCT
and ECHO. There were no significant differences between DSCT and
echocardiography ( 0.05). The diagnostic accuracy of
extracardiac malformations were 97.8% (160/164) and 71.95% (118/164)
respectively by DSCT and ECHO. There were significant differences between
DSCT and echocardiography ( <2=40.649, P < 0.01). For all the 255 places of
cardiovascular malformation, the diagnostic accuracy of DSCT,
echocardiography were 96.47% and 81.17%, respectively. There were
significant differences between DSCT or echocardiography for assessment of
cardiovascular malformation (P < 0.01).
Conclusion
DSCT is superior to echocardiography for quantitative
assessment of extracardiac malformations in patients with complicate
congenital heart disease of TOF, which is significant for clinical surgery.
14:00 - 15:30 Room P
Molecular Imaging
SS 606
Translational studies
Moderators:
C.C. Cyran; Munich/DE
J. Grimm; New York, NY/US
B-0521 14:00
Detection of early precursor lesions of pancreatic cancer using
hyperpolarised [1-13C]pyruvate
E.C.P.M. Serrao
1, M.I. Kettunen1, T.B. Rodrigues1, P. Dzien1, F.A. Gallagher1,
D. Tuveson2, K. Brindle1; 1Cambridge/UK, 2New York, NY/US
(
[email protected])
Purpose: Pancreatic ductal adenocarcinoma (PDA) is the fourth leading cause
of cancer-related deaths worldwide. Improvements in mortality may only be
possible by early diagnosis of pancreatic precursor lesions (i.e. PanIN),
however this is still challenging clinically due to the lack of sensitive and
specific biomarkers. The aim of this study was to identify metabolic signatures
associated with the different stages of PDA progression using 13C magnetic
resonance spectroscopic imaging of hyperpolarised [1-13C]pyruvate in a
genetically engineered mouse model of pancreatic cancer.
Methods
and Materials: LSL-KrasG12D/+-p48Cre/+(KC) mice with mPanIN,
LSL-KrasG12/D+;LSL-Tpr53R172H/+;Pdx-1-Cre (KPC) mice with spontaneous
pancreatic cancer and control mice were used. KPC and C57BL/6 mice were
used as models of established tumour and normal tissue, respectively. MRI
was performed at 7T using a 13C/1H volume coil/20-mm diameter 13C-surface
coil combination. A chemical shift image was acquired from a single 4-8 mm
axial slice covering the pancreas 20 sec after injection of 0.3 mL (82 mM)
hyperpolarised [1-13C]pyruvate. [1-13C]Pyruvate, [1-13C]lactate (lac) and [1-
13C]alanine (ala) signal intensities in the pancreas were analysed. 1H-NMR
spectra of tissue extracts were obtained at 14.1T (TR 12.5s) and Lac and Ala
concentrations calculated. Tissues were evaluated histologically.
Results
Progressive reduction of [1-13C]Ala/[1-13C]Lac ratio was observed
with increasing disease progression. No changes were observed in control
mice.1H-NMR spectra of tissue extracts revealed the same Ala/Lac signature.
Conclusion
[1-13C]Pyruvate metabolism and the ratio of the subsequently
formed [1-13C]Ala and [1-13C]Lac may form useful probes for detecting and
following progression of panIN lesions, before any mass-forming lesion
(tumour) can be detected by conventional imaging. This may offer an improved
diagnostic tool in high-risk populations.
Author Disclosures:
E.C.P.M. Serrao: Research/Grant Support; General Electrics. M.I. Kettunen:
Research/Grant Support; General Electrics. T.B. Rodrigues: Research/Grant
Support; General Electrics. P. Dzien: Research/Grant Support; General
Electrics. F.A. Gallagher: Research/Grant Support; General Electrics. D.
Tuveson: None. K.M. Brindle: Research/Grant Support; General Electrics.
B-0522 14:09
Evaluation of anti-angiogenic therapies using molecular MRI and DCE-US
in kidney tumour xenograft
I. Leguerney1, L. De Rochefort2, M. Poirier-Quinot2, S. Robin1,
S. Pitre-Champagnat1, X. Violas3, P. Robert3, N. Lassau1; 1Villejuif/FR,
2Orsay/FR, 3Roissy/FR (
[email protected])
Purpose: To study the interest of molecular MRI-targeted ':23 compared to
DCE-US and to evaluate several anti-angiogenic drugs in xenografted kidney
cancer.
Methods
and Materials: 24 mice were xenografted (3.106 cells A498). We
performed imaging evaluations in 4 groups, 1 control and 3 treated with
antiangiogenic drugs: monoclonal anti-body (bevacizumab), thyrosine kinase
inhibitor (sunitinib) and m-Tor inhibitor (everolimus). MR acquisitions were
performed on a 1.5 T Achieva system (Philips), using a conventional surface
coil. Susceptibility MRI was done after injection of an USPIO-RGD-based
nanoemulsion binding ':23 (P04000 Guerbet). DCE-US was performed with
Toshiba Aplio XV using high-frequency probe and microbubbles (Sonovue,
Bracco). Molecular MRI and DCE-US were performed at the same days:
baseline and D3. We evaluated R2* in the tumour 1 hour after P04000 with
MRI and blood volume using AUC for DCE-US.
S247
BA C D E F G
Friday
Results
Tumor size wassignificantly differ ent between control and treated
groups at D3 ( p=0.0099). AUC calculated with DCE-US at D3 was significantly
lowest for bevacizumab group ( p=0.008) and not significant for the two other
treatments. R2* quantification at D3, 1 hour after P04000 injection, is reduced
from 23.1±4.6 s-1 in the control group to 7.9 ±4.8 s-1 (p < 0.007) for everolimus
13.5±7.9 s-1 (p < 0.047) for bevacizumab and not significant for sunitinib.
Conclusion
Molecular imaging with ':2 3-targeting contrast agent is
complementary or even more sensitive than blood volume determination by
DCE US to detect effects of antiangiogenic drugs with different mechanism of
action.
Author Disclosures:
X. Violas: Employee; Guerbet. P. Robert: Employee; Guerbet.
B-0523 14:18
Optimisation of combination of peptide receptor radionuclide therapy
(PRRT) and temozolomide therapy using SPECT/CT and MRI in mice
S.M. Bison, J.C. Haeck, S.J. Koelewijn, M. Melis, M.R. Bernsen, M. de Jong;
Rotterdam/NL (
[email protected])
Aim:
Treatment of patients with somatostatin receptor (SSTR)-overexpressing
neuroendocrine tumours (NET) with the SST-analogue Lutetium-177-labelled
octreotate (PRRT) or the chemotherapeutic agent temozolomide (TMZ) is
successfully being applied. Their combination might result in additive effects.
Using MRI and SPECT/CT we studied tumour characteristics and therapeutic
responses after different administration schemes in a murine tumour model in
order to identify the optimal treatment schedule for PRRT plus TMZ.
Methods
and Materials:
We performed molecular imaging studies in mice bearing SSTR-expressing
H69 tumours after single i.v. administration of 30 MBq
177Lu-octreotate or TMZ
(oral 50 mg/kg daily for 14d). Weekly tumour perfusion was evaluated by DCE-
MRI, whereas tumour uptake of
111In-octreotide was quantified using
SPECT/CT until d40. Based on these results, seven different 177Lu-octreotate
and TMZ treatment schemes were evaluated, varying the order and time
interval of the two therapies besides single treatment.
Results
PRRT or TMZ resulted in reduced tumour size, accompanied by significant
changes in MRI characteristics such as intrinsic T2, T2* values and enhanced
tumour perfusion. Moreover, TMZ treatment also resulted in increasing uptake
of
111In-octreotide until d15. In the subsequent therapy study 90% of animals
receiving PRRT at d15 after TMZ treatment showed complete response;
indeed the best anti-tumour results compared to single and other combination
therapies.
Conclusions
Molecular imaging studies indicated that PRRT after TMZ treatment could
achieve optimal therapeutic effect because of enhanced tumour uptake of
radioactivity, which was confirmed in the therapy study. Therefore TMZ
administration prior to PRRT might increase tumour responses in NET patients
as well.
B-0524 14:27
A multimodal quantitative molecular imaging protocol for kidney tumor
mouse model characterisation using targeted contrast agents
M. Poirier-Quinot
1, L. de Rochefort1, I. Leguerney2, S. Robin2,
S. Pitre-Champagnat1, X. Violas3, P. Robert3, N. Lassau2; 1Orsay/FR,
2Villejuif/FR, 3Roissy-Charles-de-Gaulle/FR (
[email protected])
Purpose: Comparison of two molecular imaging techniques (US and MRI)
using targeted ':23 contrast agents in a xenograft tumor model.
Methods
and Materials: Dynamic contrast-enhanced DCE-US and dynamic
susceptibility contrast DSC-MRI with ':23-targeted contrast-agents (CA) were
applied. Mice were xenografted with a human kidney tumor: cells (3.106 cells
A498) were injected subcutaneously to 13 nude mice. At day 20-22 after
injection, mice were anesthetised (isoflurane+O2) and imaged. MR and US
targeted and non-targeted CA were injected at 2 days intervals. Apparent
Diffusion Coefficient (ADC) and DCS-MR acquisitions were done at 1.5 T
(Philips Achieva, micro23 coil). DSC were done using a USPIO-based
nanoemulsion targeted with RGD binding ':23, as well as a control
nanoemulsion (Guerbet). Molecular US acqui sitions were performed on a small
animal dedicated system (Visualsonics VEVO-2100, 20 MHz probe MS-250),
using MicroMarker
TM ':23-targeted and control (IgG) bubbles. Data were co-
localised, ROIs were drawn for analysis of: tumor size, ADC, contrast
enhancement and relaxivity R2* quantification.
Results
US and MRI tumor sizes correlated well, R=0.99 (p < 0.001 Pearson
test). ADC values and US signal enhancement on hypo- and hyper-
vascularised area correlated with R=0.73 (p=0.006 Pearson test). Targeted vs
non-targeted injections gave significantly different 1) contrast modifications for
DCE-US (p=0.0051, paired student's t-test) and 2) R2* modifications for DSC-
MRI (p=0.0286, Mann-Whitney test).
Conclusion
Multimodal evaluation of targeted CA and various imaged-derived
biomarkers for preclinical oncology may be used to follow-up treatment
response. The use of clinical imaging set-up here could allow the fast transfer
of this methodology into the clinics.
B-0525 14:36
MR imaging and targeting of a specific alveolar macrophage
subpopulation in COPD animal model using antibody conjugated
magnetic nanoparticles
A. Al Faraj, A. Sultana Shaik, B. Al Sayed, R. Halwani; Riyadh/SA
(
[email protected])
Purpose: MR Imaging of macrophages offers a promising noninvasive
approach for better assessment of the pathophysiological impairments in
COPD. Inside the body, different environmental conditions will orient
macrophages to have either proinflammatory-M1 or immunomodulator-M2
profile. The purpose of this study was to characterise the in-vivo effect of
magnetic nanoparticles (MNP) intrapulmonary administration on macrophages
polarization in COPD and to specifically target and monitor one subpopulation
using MRI.
Methods
and Materials: C O P D m i c e w e r e e x p o s e d t o P E G y l a t e d d e x t r a n -
coated MNP. Surface membrane receptor expression, iNOS vs Arginase1
production and gene expression profile were performed to have an in-depth
characterisation of macrophages polarization. CD86- or CD206-antibodies
were then conjugated to maleimide MNP to specifically target and image either
M1 or M2 macrophages using ultra-short echo time (UTE) sequence on a 4.7T
magnet. The polarization profile of antibody-MNP targeted subpopulations was
finally assessed using immunohistochemistry and flow cytometer.
Results
While a continuum balance in macrophages subpopulations was
identified during COPD, MNP intrapulm onary administration did not affect their
polarization profile. M1 and M2 macrophages were successfully targeted using
CD86- and CD206-conjugated MNP respectively. MR imaging using UTE
sequence allowed successful detection of hyper-intensity regions
homogenously distributed in COPD lung using TE=1 ms and co-localisation of
either CD86- or CD206-conjugated MNP targeted to macrophages
subpopulations as hypo-intensity void signal due to macrophages aggregates
using TE=0.4 ms.
Conclusion
Coupling of MNP with a specific antibody targeted to a particular
macrophages subpopulation could offer a promising strategy for an early and
better diagnosis of pulmonary inflammatory diseases using noninvasive MRI.
B-0526 14:45
Spatially resolved ex vivo quantification of a gadolinium-containing MR
agent by matrix-assisted laser desorption ionization imaging: correlation
to in vivo MRI
M. Wildgruber
1, M. Aichler2, K. Huber2, K. Kosanke1, E.J. Rummeny1,
A.K. Walch2; 1Munich/DE, 2Oberschleissheim/DE (
[email protected])
Purpose: To evaluate MALDI imaging for spatially resolved ex vivo
quantification of a gadolinium-based magnetic resonance agent in correlation
to in vivo magnetic resonance imaging.
Methods
and Materials: In vivo deposition of a Gadofluorine M was
investigated in a mouse model of myocardial infarction. Mice were investigated
by in vivo MRI at 7T at 6h, 24h and 48h after injection of 0.2 mmol/kg
Gadofluorine M. Delayed enhancement was detected in the infarct scar using a
conventional FLASH technique and quanti fied by calculating signal- and
contrast-to-noise ratios. In addition, T1 mapping studies were performed using
a snapshot technique. Animals were killed after each time point and hearts
were prepared for quantitative assessment by MALDI imaging.
Results
Delayed enhancement imaging revealed signal enhancement in the
myocardial scar beginning at 6h after Gadofluorine M injection with peak
enhancement at 24h hours and residual enhancement at 48h post injection.
Contrast-to-noise ratios were highest at 24h post injection due to high agent
accumulation in the infarct and low signal from the blood. T1 values in the
infarct were shortest at 6h and steadily increased to 24h and 48h post
injection. MALDI Imaging was able to corroborate the in vivo imaging results
and enabled in situ quantification of the in vivo applied Gadolfuorine M with
high-spatial resolution.
Conclusion
MALDI Imaging is able to provide a mass-specrometry-based
quantification of gadolinium-containing cont rast agents in situ with high-spatial
resolution. The results of MALDI Imaging correlate with in vivo MRI. For the
first time, quantitative ex vivo validation of in vivo contrast agent distribution is
possible.
S248
BA C D E F G
Friday
B-0527 14:54
Optoacoustic imaging and staging of rheumatoid arthritis
C. von Schacky1, N. Beziere1, Y. Kosanke1, M. Kimm1, M. Aichler2,
E.J. Rummeny1, V. Ntziachristos1, R. Meier1; 1Munich/DE,
2Neuherberg/DE (
[email protected])
Purpose: The purpose of our study was to evaluate multispectral optoacoustic
tomography (MSOT) in a murine model to visualise the extent of the
inflammation in vivo through a L- and P-selectin targeting contrast agent.
Methods
and Materials: Collagen-induced arthritis mice were used as a
rheumatoid arthritis model of the limb. Optoacoustic imaging was performed
using a L- and P-selectin targeting contrast agent (dPGS-NIR provided by
Mivenion, Germany) to increase contrast of the arthritic joint, and signal
intensity ratios between healthy and arthritic legs were calculated. Contrast-
enhanced MRI imaging as well as clinical observation, lymphocyte and
granulocyte count and histology served as references.
Results
MSOT using an inflammation targeting contrast agent allowed for
accurate spatial diagnosis of inflammation in the mouse joints and for
significant differentiation of inflamed to healthy joints (P = 0.023). The arthritis
findings on the MSOT images were c onfirmed by clinical observation, blood
analysis, contrast-enhanced MRI and ex vivo histology.
Conclusion
The combination of inflammation targeting contrast agent and
optoacoustic tomographic imaging presents a reliable and accessible method
to assess rheumatoid arthritis in respect to diagnosis and staging. Considering
the current development of the imaging technology, it is to be expected that
these approaches will be translated into clinical application as a fast and cheap
way for imaging of rheumatoid arthritis.
Author Disclosures:
V. Ntziachristos: Shareholder; Ithera Medical GmbH.
B-0528 15:03
Au@Fe3O4 Janus particles as an innovative contrast agent for future
multi-modal imaging
L. Haslauer1, P. Ernst1, I. Schick2, O. Köhler2, I. Hilger1, W. Tremel2; 1Jena/DE,
2Mainz/DE (
[email protected])
Purpose: Based on their magnetic and op tical properties, asymmetric Janus
particles (JPs) display high versatility as multi-modal imaging tools or as drug
target delivery systems. Due to poor data available on their impact on
biological systems, we investi gated newly developed Au@Fe 3O4 JPs with
varying position of amino groups on cells in culture.
Methods
and Materials: JPs consist of gold at a silica-PEG-FITC coated iron
oxide domain with thiole-groups attached to the gold part. We investigated
biocompatibility via ATPLite, ROS, H2 A.X and comet assay and uptake by
microscopy on endothelial cells and monocytes.
Results
Au@Fe
3O4 JPs mainly exhibit a better biocompatibility up to 50 g/ml
Fe (II)/(III) (85.35% viability, 72 h) compared to their spherical counterparts.
JPs with NH 2-functionalization decreased viability to 10.6%. Fe 3O4
nanoparticles induced a high release of ROS compared to Au@Fe 3O4
(189.23 % vs. 18.67%). 60%-70% of the JPs were internalised independently
from the position of amino groups at the JP domains. JP associated DNA
damage (10% higher vs. untreated cells) and a high amount of phosphorylated
histone H2 A.X (fluorescence intensity (treated/untreated): 42996 vs. 31587)
was independent from the effects on the cellular ATP levels (96% vs. control).
Conclusion
JPs offer a better biocompatibility compared to their spherical
counterparts due to antioxidative effects of the gold domain. In the view of
applications in vivo, Au@Fe
3O4 particles would be preferred towards the
Au@MnO variants because of their lower impact on cell metabolism.
Combining good biocompatibility and the known imaging properties, JPs are
very attractive for future biomedical applications.
B-0529 15:12
"To serve and protect" - enzyme inhibitors as radiopeptide escorts
promote tumour targeting
B.A. Nock1, T. Maina-Nock1, E.P. Krenning2, M. de Jong2; 1Athens/GR,
2Rotterdam/NL (
[email protected])
Purpose: Radiopeptide drugs like radiolabelled octreotide analogues are
successfully being applied for tumour visualisation and treatment. However,
translation of this paradigm to other r adiopeptide ligands has been severely
hampered by their often poor metabolic stability. We hypothesised a novel
application - co-injection of a single en zyme inhibitor - to improve peptide
bioavailability and hence tumour uptake in vivo. We co-injected radiopeptides
and phosphoramidon (PA), a potent (IC
50 34 nM) and reversible competitive
neutral endopeptidase (NEP)-inhibitor, to explore our hypothesis.
Methods
and Materials: Co-injection of PA (0.3 mg) with 111In-labeled
somatostatin, gastrin and bombesin radiopeptides was tested in different
mouse models (healthy mice as well as tumour-bearing SCID and nude mice).
At 4 and 24 h post-injection, animal SPECT/CT imaging was performed
followed by biodistribution measurements.
Results
We could provoke a remarkable and very significant rise (up to 40
times the control values) in the percentage of circulating intact 111In-labelled
somatostatin, gastrin and bombesin radiopeptides in healthy mice after PA co-
injection. Most importantly, this strategy resulted in a spectacular increase of
radiolabel accumulation (up to 14 times the control values) in different types of
tumours xenografted in the mice. The improved tumour uptake could be clearly
visualised by SPECT/CT as well.
Conclusion
Our findings open exciting new op portunities for the application of
biodegradable peptide-drugs of either natural or synthetic origin as well as for
the rationale design of in vivo stable analogues. They also provide a versatile
tool for elucidating enzyme-peptide interactions.
B-0530 15:21
Camelid reporter gene imaging: a generic method for in vivo cell tracking
of fluorescent/luminescent cells
L.R.Y. Goethals
1, G.-J. Allemeersch1, T.J. Bos2, J. de Mey1, T. Lahoutte1;
1Jette/BE, 2La Jolla, CA/US (
[email protected])
Purpose: To combine the sensitivity of bioluminescent imaging (BLI) with the
3D and quantitative properties of SPECT/micro-CT, we generated cell lines
expressing a Yellow-Fluorescent-Protein and Gaussia Luciferase fusion protein
(YFP/GLuc). For in vivo SPECT detection of this YFP/GLuc, a nanobody,
binding yellow and green fluorescent proteins (anti-YFP-Nb), was labelled with
99mTc.
Methods
and Materials: 10E5 HEK 293 T-cells were transduced with
YFP/GLuc containing vector: both membrane-targeted (MT-YFP/GLuc) and
non-targeted (YFP/GLuc) fusion proteins were developed. These were
compared against a cell line expressing Green-Fluorescent-Firefly Luciferase
(GFP/Fluc) and cells expressing Red Fluorescent Protein in combination with a
Gaussia Luciferase (Red/GLuc). Transduction efficiencies were scored by
fluorescence microscopy; cells were enriched by FACS. Luciferase
functionality was tested in vitro by BLI. Subsequently, cells were transplanted
subcutaneously in athymic mice (MT-YFP/GLuc: n=4, YFP/GLuc: n=6,
GFP/Fluc: n=6, Red/GLuc: n=4). After transplantation, in vivo BLI was
performed. Labelling efficiency of anti-YFP-Nb was measured using ITLC. One
week after transplanation, 99mTc labelled anti-YFP-Nb was injected
intravenously and SPECT/micro-CT was performed.
Results
Cells containing MT-YFP/GLuc were positive on fluorescent
microscopy, with fluorescent signal confined to the cell membrane. Transduced
cells were assayed by BLI and showed a significantly higher light output both in
vitro and in vivo. Anti-YFP-Nb labelling efficiency was 98% and SPECT/Micro-
CT demonstrated higher transplant to muscle ratio for both the MT-YFP/GLuc
and YFP/GLuc groups, compared with the GFP/FLuc and Red/GLuc group.
Conclusion
This study provides a proof-of-principle for a nanobody-based cell
tracking method, using a YFP/Gluc fusion protein and anti-YFP-Nb.
S249
BA C D E F G
S250
BA C D E F G
Saturday
10:30 - 12:00 Room C
Abdominal Viscera
SS 901a
Liver tumours: CT and MRI
Moderators:
D.M. Lambregts; Maastricht/NL
N.C. Tarhan; Ankara/TR
B-0531 10:30
Hepatocellular carcinoma (HCC) is more advanced at diagnosis in HIV-
HCV (human immunodeficiency virus-hepatitis C virus) co-infected than
in HCV mono-infected cirrhotic patients
M. Lewin
1, M. Gelu-Simeon1, R. Sobesky1, M. Ostos1, E. Teicher2, L. Meyer2,
O. Seror3, J.-C. Trinchet3, J.-C. Duclos-Vallée1; 1Villejuif/FR,
2Le Kremlin-Bicêtre/FR, 3Bondy/FR (
[email protected])
Purpose: To characterise the imaging of HCC in HIV-HCV co-infected cirrhotic
patients compared to mono-infected HCV cirrhotic patients.
Methods
and Materials: HCCs from a multi-centric cohort of 35 HIV-HCV
cirrhotic patients (32 males, median age 50 years old [43-65], median CD4
count: 345 cells/mm 3 [24-1121], median duration from cirrhosis to HCC
diagnosis: 4.5 years) and from a control group of 35 HCV cirrhotic patients (29
males, median age 56 years old [41-83]) were retrospectively included. CT or
MRI image analysis was focused on the detection of nodular or infiltrative
forms with evaluating the number and size of the nodules, evidence for
vascular invasion and signs of portal hypertension. Fisher and Wilcoxon tests
were used for statistical analysis.
Results
An infiltrative form was found in 8/35 HIV-HCV versus 0/35 in HCV
patients (22.9% and 0%, respectively, p=0.002). Other HCCs were nodular in
nature. A single nodule was found in 20/35 HIV-HCV (57%) and in 19/35 HCV
patients (54%). The largest nodules had a median diameter of 25 mm [12-130]
in HIV-HCV versus 21 mm [13-90] in HCV patients. Tumour portal thrombosis
was found in 10/35 HIV-HCV (including 5 infiltrative form) versus 0/35 in HCV
patients (28.5% and 0%, respectively, p=0.028). Portal hypertension signs
were seen in 29/35 (83%) HIV-HCV patients and in 22/35 (63%) HCV patients.
Conclusion
Compared to HCV mono-infected reference patients, HCC in
HIV-HCV co-infected patients revealed to be at a more advanced stage at
diagnosis with a significantly higher occurrence of infiltrative form and of
tumour portal thrombosis.
B-0533 10:39
Preoperative T-Staging of gallbladder carcinoma using gadoxetic acid-
enhanced MR imaging: emphasis on usefulness of the hepatobiliary
phase
E. Oh, J. Hwang, Y. Kim, S. Hong; Seoul/KR (
[email protected])
Purpose: To evaluate diagnostic performance of gadoxetic acid-enhanced MR
imaging with an emphasis on the usefulness of hepatobiliary phase (HBP) in
the preoperative T-staging of gallbladder carcinoma.
Methods
and Materials: Sixty-six patients with surgically confirmed
gallbladder carcinoma underwent MR imaging. Two radiologists independently
reviewed two sets of gadoxetic acid-enhanced MR imaging without HBP and
with HBP. Local tumour spread was evaluated according to the T-staging, and
the results were compared with pathologic findings. The diagnostic
performance of two image sets to differentiate each T-stage was compared.
Results
The sensitivities of MR imaging with HBP to differentiate T1 versus
T2 lesions, T2 versus T3 lesions, and T3 versus T4 lesions were 96.3%,
85.7%, and 100% for observer 1, and 92.6%, 95.2%, and 100% for observer 2,
respectively (P < 0.0001). By adding HBP, the sensitivities to differentiate T2
versus T3 lesions were increased from 66.7% to 85.7% for observer 1 and
from 81.0% to 95.2% for observer 2, although there was no significant
difference (P > 0.05). The overall accuracies for T-staging were increased from
80.3% to 86.4% for observer 1, a statistically significant degree (P = 0.046),
and from 83.8% to 87.9% for observer 2 (P > 0.05). The k value for the two
observers indicated excellent agreement.
Conclusion
Gadoxetic acid-enhanced MR imaging provided acceptable
diagnostic performance for the preoperative T-staging of gallbladder
carcinoma. Addition of HBP aid in the detection of liver invasion.
B-0534 10:48
The prevalence of potentially serious incidental findings on abdominal
magnetic resonance imaging: a systematic review
L.M. Gibson, L. Paul, C.L.M. Sudlow; Edinburgh/UK (
[email protected])
Purpose: To perform a systematic review to estimate the prevalence and
types of incidental findings on abdominal magnetic resonance (MR) imaging to
inform the design of the UK Biobank multi-modal imaging study of 100,000
middle-aged participants.
Methods
and Materials: We searched authors' files, Medline and Embase for
studies published in any language by June 2013 which reported the prevalence
of incidental findings on abdominal MR in adult patients or apparently healthy
volunteers. We defined serious incidental findings as those likely to threaten
lifespan, quality of life or major body functions. One reviewer selected studies
for inclusion and a second independently checked 10% of the references. We
extracted data on incidental findings, participant characteristics and imaging
variables
Results
We included 11 studies of 85,322 participants (mean age 51 years,
42% female). The largest (n=79,121 patients) only assessed incidental
abdominal aortic aneurysms (0.94% (95% confidence interval [CI] 0.8-1.1%).
Of the remaining 6,201 participants, 3,959 had incidental findings which were
potentially serious in 413 (6.7%, 95% CI 6.1-7.3%), including 104 suspected
malignancies. The most frequent non-malignant serious findings were
pancreatic cysts (n=154), ascites (n=76) and pleural effusion (n=21).
Potentially serious incidental findings were detected more frequently in studies
which used contrast compared to non-contrast imaging (23% vs 2%). One
study (n=132) used a 3 T scanner, and the remainder used 1.5 T scanners.
Conclusion
Potentially serious incidental findings are common on abdominal
MR and will often require further investigations. This should be discussed with
research participants and patients when seeking informed consent.
Author Disclosures:
L.M. Gibson: Research/Grant Support; unding from UK Biobank to attend
educational meetings. C.L.M. Sudlow: Other; UK Biobank Chief Scientist.
B-0535 10:57
Qualitative analysis of small (2 cm) regenerative nodules, dysplastic
nodules and well-differentiated HCCs with gadoxetic acid MRI
M. Di Martino1, R. Di Miscio1, C.V. Lombardo1, L. Saba2, C. Catalano1;
1Rome/IT, 2Cagliari/IT (
[email protected])
Purpose: To evaluate radiological findi ngs and diagnostic accuracy of
gadoxetic acid magnetic resonance imaging (MRI) in the evaluation of small
(2 cm) regenerative nodules (RN), dysplastic nodules (DN) and well-
differentiated hepatocellular carcinomas (HCCs).
Methods
and Materials: Sixty-two cirrhotic patients, with 107 focal liver
lesions were prospectively recruited. MR examinations were performed with a
3 T magnet (Discovery MR750; General Eletric Systems). The MRI study
protocol included T1-weighted and T2-weighted pre-contrast sequences and
3D-spoiled gradient-echo T1-weighted post-contrast sequences Gd-EOB-
DTPA-enhanced obtained during the arterial, portal-venous and equilibrium
phases 25 s, 70 s 180 s and after 20 m. All lesions (33 RN, 29 DN and 45
HCCs) were pathologically confirmed. One radiologist not involved in the
datasets analysis reported the signal intensity characteristics of each lesion.
Two radiologists blinded to clinical and pathological information evaluate
radiological dataset images. Sensitivity, specificity and diagnostic accuracy
were considered for statistical analysis.
Results
Regenerative nodules usually show enhancement during the arterial
phase without wash-out sign during portal-venous and delayed phase.
Dysplastic nodules tend to do not show enhancement during the arterial phase
and present wash-out on delayed phase. Well-differentiated HCCs very often
show typical vascular pattern (wash-in and wash-out) and low-signal intensity
during the hepatobiliary phase. According to the AASLD radiological diagnosis
the mean sensitivity, specificity and di agnostic accuracy in the diagnosis of
HCC were, respectively (76.4%, 80%, 0.84).
Conclusion
Gadoxetic acid MR imaging is a reliable tool in the
characterisation of well-differentiated HCC from dysplastic and regenerative
nodules.
S251
BA C D E F G
Saturday
B-0536 11:06
Comparison of PET fused with MR, PET/CT and MR alone in
characterising hepatic lesions
E.B. Uglow, A. Parsai, Y. Bouchareb, T. Szyszko; London/UK
(
[email protected])
Purpose: To compare PET fused with MR (fused-PET/MR), PET/CT and MR
with gadolinium ± diffusion weighting for detecting and characterising hepatic
lesions.
Methods
and Materials: This is a retrospective review of 36 hepatic lesions in
20 patients (mean age 58 years ±14 yrs). All patients had both a PET/CT and
MR scan. The mean time between scans was 42 days ± 30 days. PET/CT and
MR scans were fused using the HERMES® software and reviewed by 2
readers, who used a scale of 1-5 to characterise lesions as benign (1),
malignant (5) or indeterminate (3). The final diagnosis was determined by
histopathology or follow-up imaging. PET/CT and MR alone were later
reviewed independently to avoid bias.
Results
36 lesions were detected using fused-PET/MR and MR alone. 28/36
were detected with PET/CT alone. 26/36 were benign lesions and 10/36 were
metastatic hepatic lesions. All lesions were correctly characterised as benign
or malignant by PET/ MR. 31/36 lesions were correctly characterised by MR
alone. All 28 lesions detected by PET/CT alone, were correctly characterised.
5 indeterminate lesions on MR were correctly characterised by the addition of
PET/CT
Conclusion
MR has a high sensitivity (100% ) for detecting hepatic lesions,
however, it correctly characterises only 86% of these lesions. PET/CT has a
lower sensitivity for detecting lesions (78%), however, it correctly characterised
100% of those lesions detected. Fused-PET/MR is able to correctly
characterise those lesions indeterminate on MR alone. Fused-PET/MR
provides optimal sensitivity and characterisation of hepatic lesions.
B-0537 11:15
Interest of shear wave elastography in the determination of malignancy
for focal liver lesions
W. Ben Hassen, M. Wagner, L. Chami, S. Egels, J.-M. Correas, O. Lucidarme;
Paris/FR
Purpose: To assess the stiffness of various focal liver lesions (FLL) using
Supersonic Shearwave Elastography (SSE).
Methods
and Materials: SSE were performed in 115 patients (mean age:56.2
years; range 21-89) with 121 FLL (79 benign, 42 malignant, mean size:
27.4 mm). Final diagnosis was assessed wi th pathological examination in all
cases of malignant and atypical benign lesions, and with CT or MRI when
typical patterns of hemangiomas or focal nodular hyperplasia (FNH) were
found. Three consecutives measurements in kilopascals were performed in the
center of each lesion and in surrounding normal parenchyma. Average values
and the ratio between values of elasticity in FLL and values of elasticity of
normal liver were then computed.
Results
79 benign lesions (40 hemangiomas, 23 FNH, 6 adenomas, and 10
others benign lesions), and 42 malignant lesions (16 hepatocellular carcinomas
and 26 metastases) were analysed. Malignant lesions exhibited a mean
stiffness value of 52.78kPa± 32.85, whereas benign lesions had an elasticity
value of 25.03kPa ±18.9; P < 10-4). The ratio between FLL and surrounding
normal liver was more important in malignant lesions (5.8± 4.3) than for benign
ones (3.8 ±2.95; P < 0.002). Mean stiffness values differed significantly
between the three groups of lesions (benign lesions, HCC and metastases:
Metastases exhibited the highest values of stiffness (P < 10-4) and highest
stiffness ratio (P < 10-4). Hepatic hemangiomas showed the lowest values of
stiffness compared to the other lesions (P < 10-4).
Conclusion
SSE provides addi tional information that po tentially could help in
liver lesion characterisation with US, particularly to differentiate benign lesions
from HCC and metastases.
B-0538 11:24
Pattern of HCC recurrence after liver transplantation: time to modify the
current follow-up imaging modalities?
M. Dioguardi Burgio1, M. Ronot2, D. Fuks2, F. Dondero2, F. Cauchy2,
V. Paradis2, F. Durand2, J. Belghiti2, V. Vilgrain2; 1Palermo/IT, 2Clichy/FR
(
[email protected])
Purpose: To analyse the imaging characteristics of hepatocellular carcinoma
(HCC) recurrence following liver transplantation (LT) in order to determine
whether the current follow-up imaging modalities are relevant in the detection
of these recurrences.
Methods
and Materials: Among 336 cirrhotic patients undergoing LT between
2000 and 2011, 25 (7.4%) experienced HCC recurrence. Their pre-LT
characteristics, long-term outcome and imaging characteristics of recurrences
were retrospectively analysed.
Results
All patients were males [median age 54 (41-64) years]. Before LT, 13
(52%) patients had lesions outside the M ilan criteria. Median time to HCC
recurrence was 13.8 (1-75) months following LT and 8 (32%) patients
experienced recurrence > 24 months after LT. Recurrences were detected
using routine US follow-up in only 7 (28%) patients, and CT/MRI imaging in 18
(72%) of the patients including 5 (20%) based on alpha-fetoprotein elevation.
The most frequently involved organs were the lungs in 13 (52%) cases and the
bones in 9 (36%) cases. Recurrent HCC involved > 1 organ in 11 (44%)
patients. Recurrences were limited to the liver in one (4%) patient, were
exclusively extrahepatic in 18 (72%) patients and were both intrahepatic and
extrahepatic in six (24%) patients.
Conclusion
Routine US examination alone failed to detect most HCC
recurrences. Because HCC recurrence may occur even in patients with
favourable prognostic factors, is mainly extra-hepatic, may be delayed, and is
rarely identified using US examination, we suggest performing regular whole-
body imaging during follow-up visits 2 years or more after LT.
B-0539 11:33
Alignment of abdominal organs in a sequential PET/MRI
C. Rubbert1, A.A. Kohan2, J.L. Vercher-Conejero2, K.A. Herrmann2,
R.R.F.J. Muzic2, P.R. Ros2, P.F. Faulhaber2; 1Düsseldorf/DE, 2Cleveland,
OH/US (
[email protected])
Purpose: A commonly discussed disadvantage of sequential PET/MRI is the
effect of spatially and temporally disp laced PET and MRI acquisitions. This
study aims to quantitatively evaluate automatic image fusion of upper
abdominal organs, which are subject to breathing movement.
Methods
and Materials: 11 patients with PET and MRI acquisitions of the
upper abdomen were evaluated under an IRB-approved PET/CT (Philips
Gemini TF) and PET/MRI (Philips Ingenuity TF) protocol. Volumes of interest
(VOIs) were defined in a unified coordinate system for the liver, spleen and
kidneys. Dice coefficients were used to evaluate the overlap of corresponding
VOIs in PET and CT from PET/CT. The same procedure was performed for
image fusion of PET with the best-matching MRI, PET and the worst-matching
MRI, as well as both MRI sequences fused. Dice coefficients were interpreted
analogously to Kappa statistics (0.61-0.8 = good, > 0.8 = excellent).
Results
Overlap of VOIs in PET/CT was excellent for the liver (0.84 ±0.08) and
good for the spleen (0.75 ±0.06) and each kidney (0.74 ±0.12, 0.79±0.05). PET
and best MRI overlap was excellent in liver (0.85 ±0.03) and spleen (0.80 ±0.06)
and good in each kidney (0.75 ±0.07, 0.78±0.07). The results were comparable
with the worst-aligned PET/MRI. Overlap was excellent in all organs when
comparing fused MRI sequences.
Conclusion
Despite sequential PET and MRI acquisitions, organ overlap in
PET/MRI has been found robust and comparable to PET/CT.
Author Disclosures:
C. Rubbert: Other; CWRU Fellowship 2012/13 funded, Koninklijke Philips
Electronics NV. A.A. Kohan: Other; Fellowship funded, Koninklijke Philips
Electronics NV. J.L. Vercher-Conejero: Other; Fellowship funded, Koninklijke
Philips Electronics NV. K.A. Herrmann: None. R.R.F.J. Muzic:
Research/Grant Support; Koninklijke Philips Electronics NV. P.R. Ros:
Investigator; Koninklijke Philips Electronics NV. P.F. Faulhaber: Investigator;
Koninklijke Philips Electronics NV.
B-0540 11:42
64-row perfusion CT of hepatocellular carcinoma with the axial shuttle
technique and adaptive statistical iterative image reconstruction:
preliminary experience
L. Faggioni
1, E. Neri1, G. D'Ippolito2, F. Pancrazi1, B. Ginanni1, R. Sacco1,
G. Bresci1, C. Bartolozzi1; 1Pisa/IT, 2São Paulo/BR (
[email protected])
Purpose: To assess the feasibility of CT perfusion imaging (pCT) of
hepatocellular carcinoma (HCC) on a 64-row scanner with extended lesion
coverage and adaptive statistical iterative image reconstruction.
Methods
and Materials: Nineteen patients (total 24 HCC) underwent pCT on
a high-definition 64-row CT scanner (Discovery CT750 HD, General Electric)
with z-axis coverage of 8 cm obtained through continuous table toggling (axial
shuttle) and an adaptive statistical iterative reconstruction algorithm (ASiR™).
All pCT examinations were performed using a low-dose protocol (tube voltage
80 kV, current 200 mA, rotation time 0.4 s) and 40% ASiR at 5 mm slice
thickness. Blood flow (BF), blood volume (BV), mean transit time (MTT),
hepatic arterial fraction (HAF), and permeability-surface product (PS) were
computed in HCC and in the surrounding liver parenchyma. The rate of non-
assessable HCC lesions and dose-length product (DLP) values were
compared with those of 14 patients (total 23 HCC) previously evaluated on a
64-row scanner with standard filtered backprojection (FBP) and 4 cm
coverage.
Results
BF, BV, HAF, and PS were higher, and MTT lower in HCC than in the
surrounding liver parenchyma (p < 0.01). The rate of non-assessable lesions
and DLP were lower with the 8 cm coverage, ASiR scanner than with the 4 cm
coverage, FBP scanner (11% vs 26%, p=0.015 and 215.8 ±77.1 vs
598.2±135.4 mGycm, p < 0.01, respectively).
S252
BA C D E F G
Saturday
Conclusion
Compared with a standard pCT protocol, 64-row pCT of HCC
lesions with extended lesion coverage and adaptive statistical iterative
reconstruction can yield a significantly higher rate of assessable lesions with a
lower radiation dose.
10:30 - 12:00 Room D
Chest
SS 904
Interstitial lung disease, lung function and
infection
Moderators:
E. Castañer; Sabadell/ES
A.P. Parkar; Bergen/NO
B-0541 10:30
Comparison of HRCT data in idiopathic pulmonary artery hypertension
(IPAH) and normals using fractal dimension analysis
M.A. Arshad
1, L. Howard1, E. Chan2, S. Giannarou1, G.-Z. Yang1, S. Copley1;
1London/UK, 2High Wycombe/UK (
[email protected])
Purpose: To investigate if a difference exists in the lung microstructure on
high-resolution CT (HRCT) images between patients with idiopathic pulmonary
artery hypertension (IPAH) and normal individuals using fractal dimension (FD)
analysis (an index of complexity).
Methods
and Materials: A retrospective analysis was performed on 42
patients (mean age 51.8, range 21-84 years, sex 15 males, 27 females)
confirmed with IPAH and 16 normals (mean age 41.5, range 21-75 years, sex
7 M, 9 F). The IPAH group underwent HRCT and concurrent right heart
catheterisation. The normals undertook HRCT and pulmonary function testing.
Pulmonary regions of interest were assessed with FD analysis. The minimum,
maximum and mean fractal values were compared for the two groups. The
fractal values for the IPAH group were correlated with the following
catheterisation parameters: mean arterial pressure (MAP), pulmonary vascular
resistance (PVR) and pulmonary vascular resistance index (PVRi).
Results
Significant differences in the fractal values between the two groups
were observed. Comparing IPAH with normals, the minimum (34.3 ± 9.43 vs
49.3 ± 6.40), maximum (78.5 ± 9.34 vs 103 ± 12.9) and mean (56.4 ± 9.37 vs
76.2 ± 7.33) fractal values were all significantly less (p < 0.0001) in the IPAH
group. However, no significant correlation was found between the fractal
values and the MAP, PVR and PVRi in the IPAH group.
Conclusion
The lung parenchyma of patients with IPAH has significantly
different CT complexity compared with normal individuals. This may provide a
useful non-invasive marker for screening and monitoring treatment response.
Author Disclosures:
E. Chan: Employee; Janssen-Cilag Ltd, Johnson & Johnson.
B-0542 10:39
Quantitative CT in the follow-up of functionally stable lung transplant
recipients
M. Silva1, D. Kienzl2, C. Mueller-Mang2, P. Jaksch2, W. Klepetko2,
A.A. Bankier1; 1Boston, MA/US, 2Vienna/AT (
[email protected])
Purpose: To quantify lung parenchymal changes in functionally stable lung
transplant recipients using combined inspiratory and expiratory CT.
Methods
and Materials: Twenty patients after double lung transplantation, all
of which were stable with regards to clinical presentation and lung function
(i.e., no evidence of graft rejection), underwent yearly combined inspiratory and
expiratory CT examinations over 5 years. Lung parenchymal densitometric and
quantitative airway metrics were calculated with dedicated software. The
longitudinal evolution of the metrics was compared within individual patients,
and relative changes were compared betwe en individuals. Comparisons were
performed using analyses of variance for repeated measurements, and linear
regression analyses were used for data modeling.
Results
Over the 5-year study period, CT measured lung weight and
histogram peaks showed statistical ly significant (p = 0.012 and p < 0. 001,
respectively) decreases. Moreover, mean lung density (MLD) significantly
decreased (p = 0.029), with regression lines showing similar slopes between
patients (F = 2.69; p = 0.036). Simultaneously, MLD on expiratory CT
examinations also significantly decreased (p = 0.001), while quantitative airway
metrics such as wall thickness, wall area percentage and Pi10 did not
significantly change over time.
Conclusion
On quantitative CT, functionally stable lung transplant recipients
show a consistent pattern of longitudinal tissue loss, combined to increasing
gas trapping. None of these changes are detected by the lung function test
currently used as reference standard for following these patients.
B-0543 10:48
Impact of iterative reconstructions on detection of systemic sclerosis
(SSc): related interstitial lung disease: clinical experience in 55 patients
F. Pontana, A.-S. Billard, K. Yasunaga, S. Bendaoud, J.-B. Faivre,
M. Remy-Jardin; Lille/FR (
[email protected])
Purpose: To evaluate the impact of iterative reconstructions on the depiction
of SSc -related lung infiltration.
Methods
and Materials: 55 patients were enrolled in a study comparing
reduced-dose and full-dose images simultaneously available from the same
dataset acquired on a dual-source CT unit with (a) both tubes set at similar
energy (120 kVp); (b) the total reference mAs (i.e., 110 mAs) split up in a way
that 40% was applied to tube A and 60% to tube B. Two series of images were
generated: (a) full-dose images (generated from both tubes), reconstructed
with FBP (Group 1) (i.e., the reference standard); (b) reduced-dose images
(generated from tube A; 60% dose reduction) reconstructed with SAFIRE
(Group 2).
Results
In Group 1: (a) the mean level of objective noise was 26.23 ±9.40 HU;
(b) CT features of lung infiltration were depicted in 38 patients (69.1%) in
whom the following findings were seen: fine reticular opacities (38/55; 69.1%);
mild ground glass opacities (GGO) (38/55; 69.1%);
bronchiectasis/bronchiolectasis (27/55; 49.1%) and honeycombing (17/55;
30.9%). Comparing Group 2 and Group 1: (a) despite dose reduction, the
Objective
noise was significantly reduced (22.02 ±6.94 HU; p < 0.001); (b) there
was a similar detection of interstitial lung disease in 38 patients (p=1); (c)
similar subjective depiction of bronchi ectasis/bronchiolectasis (p=0.776) and
honeycombing (p=1); (d) improved visual depiction of fine reticular opacities
and GGO (p=0.0186); and (e) similar good interobserver agreement (k > 0.8).
Conclusion
The image quality and diagnostic value of reduced-dose images
reconstructed with SAFIRE is comparable to that of full-dose FBP images.
B-0544 10:57
Impact of scanning conditions in the evaluation of pulmonary blood
volume with dual-energy CT: results in 42 subjects
F. Molinari, P. Felloni, F. Pontana, N. Tacelli, T. Santangelo, M. Remy-Jardin;
Lille/FR (
[email protected])
Purpose: To evaluate the characteristics of pulmonary blood volume (PBV) on
dual-energy CT examinations.
Methods
and Materials: 42 patients were eligible to this study on the basis of
(a) the absence of respiratory disease after a diagnostic work-up including a
dual-source, dual-energy chest CT angiographic examination; (b) that was
rated with an excellent image quality. Qualitative analysis was based on visual
assessment. Quantitative analysis measured the (a) iodine concentration per
lung (IPIPE software; Siemens) and (b) regional distribution of iodine after
semi-automatic division of each lung into 18 areas (OSIRIX).
Results
The iodine (I) concentration di d not significantly differ between the
right (R) (1.54 ±0.43 mg I/mL) and left (L) (1.53 ±0.41 mg I/mL) lungs with a
mean attenuation of 41.35 HU (R lung) and 41.14 HU (L lung) (p=0.49). Three
regional gradients of attenuation were observed : (a) infero-superior
(p < 0.001), linked to the conditions of examination (mean : -6.23 in the R
lung; -5.96 in the L lung); (b) postero-anterior (p < 0.001) due to gravity (mean
: 11.92 in the R lung; 15.93 in the L lung) et (c) cortico-medullary (p < 0.001)
(mean : -9.35 in the R lung; -8.37 in the L lung). The intensity of the postero-
anterior (r=0.42; p < 0.001) and cortico-medullary (r=0.58; p < 0.0001)
gradients was correlated to the overall iodine concentration. 7% of segments
(59/840) showed artifacts hampering perfusion analysis, related to beam-
hardening (RS1; RS2) or cardiac motion (RS5, LS5) artifacts.
Conclusion
Distribution of PBV is influenced by physiological gradients and
scanning conditions.
B-0545 11:06
In vivo visualisation of pulmonary emphysema using grating-based x-ray
dark-field imaging
K. Hellbach
1, A. Yaroshenko2, A. Velroyen2, F. Bamberg1, K. Nikolaou1,
M.F. Reiser1, F. Pfeiffer2, A.Ö. Yildirim3, F.G. Meinel1; 1Munich/DE,
2Garching/DE, 3Neuherberg/DE (
[email protected])
Purpose: Conventional chest radiographs have a limited sensitivity for the
detection of mild to moderate emphysema. The purpose of this study was to
assess whether grating-based x-ray dark-field imaging can be used to visualise
pulmonary emphysema in vivo in a small-animal model.
Methods
and Materials: To generate a murine model of pulmonary
emphysema, three female C57BL/6N mice were treated with a single
orotracheal application of porcine pancreatic elastase (100 U/kg body weight)
dissolved in phosphate-buffered saline (PBS). Three control mice received
S253
BA C D E F G
Saturday
PBS. Mice were imaged in vivo using a prototype grating-based small animal
scanner. The anaesthetised mice were breathing freely during the image
acquisition. The resulting images were processed using Fourier decomposition
to obtain transmission images (equivalent to a conventional radiograph) and x-
ray dark-field images. In vivo pulmonary function tests were performed before
sacrificing the mice and analyzing the lungs by histopathology.
Results
Pulmonary function tests and histopathology confirmed that mice in
the elastase group but not in the PBS group had developed emphysema after
21 days. Specifically, histopathology demonstrated diffuse airspace widening
and loss of normal alveolar architect ure. Tissue elastance was significantly
lower in the emphysema group than in the control group (18 vs.
34 cmH2O/mL). The dark-field signal intensity of the lung parenchyma was
significantly lower in the emphysema group compared to the control group
allowing for a clear discrimination between healthy and emphysematous mice.
Conclusion
X-ray dark-field projection images can be used to diagnose
pulmonary emphysema in living mice.
B-0546 11:15
Imaging of pulmonary emphysema: correlation of FEV1% with
quantitative volumetric CT analysis of pulmonary volume and
emphysema
F. Doellinger
1, R.-H. Huebner1, J.-M. Kuhnigk2, N.F. Schreiter1, C. Haberstroh1,
V. Froeling1, A. Poellinger1; 1Berlin/DE,
2Bremen/DE (
[email protected])
Purpose: FEV1/FVC ratio (FEV1%) is an important clinical parameter in the
evaluation of patients with COPD and pulmonary emphysema (PE). The aim of
this study was to assess correlations between FEV1% and parameters of
quantitative volumetric CT analysis.
Methods
and Materials: 33 patients with confirmed COPD GOLD IV and PE
were evaluated with inspiratory and expiratory chest CT. We performed
computerised quantitative analysis of lung parenchyma to detect total lung
volume and proportionate emphysema. The used software MeVisPULMO 3D
(v3.42, Fraunhofer MEVIS, Bremen, Germany) can detect lung areas with a
physical density below -950 HU and determine the ratio of normal and
emphysematous lung parenchyma (i.e. emphysema score). We calculated the
relative differences of lung volumes and emphysema scores between
inspiration and expiration.
Results
FEV1% ranged from 12.0 to 42.0% (mean 26.50%). The relative
differences of lung volumes between inspi ration and expiration ranged from
67.38 to 99.71% (mean 85.62%). There was a strong statistical correlation of
low FEV1% and small differences of lung volumes (p <.005). The relative
differences of emphysema scores between inspiration and expiration ranged
from +11.94 to -45.21% (mean -20.95%). There was a strong statistical
correlation of low FEV1% and small differences of emphysema scores (p
=.026).
Conclusion
Small relative differences of lung volumes and emphysema
scores between inspiratory and expiratory CT show a significant correlation
with low FEV1% in patients with COPD GOLD IV and PE.
B-0547 11:24
Digital tomosynthesis vs radiography in detection of fungal pneumonia: a
computer simulated clinical trial
R.M. Edwards, G. Kicska; Seattle, WA/US (
[email protected])
Purpose: Compare simulated digital tomosynthesis (sim-DTS) to radiography
in the detection of fungal pneumonia, using chest computed tomography (CT)
as the gold standard.
Methods
and Materials: 52 patients with fungal pneumonia and 13 normal
controls were identified that had undergone unenhanced chest CT and chest
radiograph within a 7 day period. Fungal pneumonia was confidently identified
on CT, the gold standard, but was marginally detectable on radiography. Sim-
DTS images were created from the CT examination. Four cardiothoracic
radiologists with minimal tomosynthesis experience reviewed the images and
rated likelihood of fungal pneumonia on a 1 to 10 point scale. Diagnostic
performance was evaluated by ROC analysis. Area under the curve (AUC) and
specific performance was compared for both modalities.
Results
All cases of fungal pneumonia demonstrated pulmonary nodules.
Median largest nodule size was 18 mm. Observer performance for all readers
showed area under the curve (AUC) of 0.83 for tomography (95% CI: 0.78-
0.89) and 0.79 for radiography (95% CI: 0.72-0.85). There is no statistically
significant difference between tomography and radiography (p-value = 0.28)
performance in fungal pneumonia detection. When considering a desired
sensitivity of 90%, specificity was 29% for tomography (95% CI:30-43) and
36% for tomography (95% CI:25-58).
Conclusion
This study suggests that digital tomosynthesis performs as well
or better than radiography, despite being interpreted by radiologists with
minimal or no tomosynthesis experience. When interpreting studies to
maximise sensitivity, tomosynthesis may have higher specificity, which would
significantly reduce unnecessary CT exams in neutropenic patients who are
routinely screened for infection.
Author Disclosures:
G. Kicska: Grant Recipient; General Electric.
B-0548 11:33
The development of diagnostic accuracy and search pattern behaviour in
the interpretation of chest radiographs
B.S. Kelly, L.A. Rainford, E.C. Kavanagh, R. Toomey; Dublin/IE
(
[email protected])
Purpose: To investigate the development of radiological image interpretation
skill through medical training by measuring both diagnostic accuracy and eye
movements during visual search.
Methods
and Materials: Five Consultant Radiologists, deemed the reference
expert group, four Radiology Registra rs, five Senior House Officers (SHOs)
and six Interns formed four clinician groups. Participants were shown 30 chest
radiographs, 14 of which had a pneumothorax and were asked to give their
level of confidence as to whether a pneumothorax was present. Receiver
operating characteristic (ROC) analysis was carried out on diagnostic
decisions. Eye movements were recorded by a Tobii TX300 eye tracker. Four
Eye-tracking metrics were analysed. Variables were compared to identify any
differences between groups.
Results
All data were compared using the Friedman non-parametric method.
The average area under the ROC Curve for the groups increased with
experience (p=0.009). Statistically significant difference in diagnostic accuracy
was found between Consultants and Registrars (p=0.046). All four eye-tracking
metrics reduced with experience, this was statistically significant for Registrars
compared with SHOs. The total reading time reduced with experience;
significantly for Registrars compared to SHOs (p=0.046) and between SHOs
and Interns (0.025).
Conclusion
Reader performance increased with experience. The level of
experience at which there was a statistically significant difference was higher
for diagnostic accuracy than for eye-tracking metrics. This data would suggest
that specific training is needed to improve radiology expertise and that the
development of an "expert" search pattern predates the development of
"expert" levels of diagnostic accuracy.
B-0549 11:42
Comparison study of chest radiography, digital tomosynthesis and low-
dose MDCT to detect ground-glass nodules: an anthropomorphic chest
phantom study
K. Doo
1, E.-Y. Kang1, H. Yong1, S.-Y. Ham1, K. Lee2, J. Choo2; 1Seoul/KR,
2Asan/KR (
[email protected])
Purpose: The purpose of this study was to evaluate the comparison of
diagnostic performance of chest digital tomosynthesis (DT), chest radiography
(CR) and low-dose CT (LDCT) for the detection of ground-glass opacity (GGO)
pulmonary nodules, using an anthropomorphic chest phantom.
Methods
and Materials: Artificial pulmonary nodul es (diameter: 5 and 8 mm,
CT densities: -630 and -800 HU) were placed in a phantom and total 40
samples of different nodule settings underwent CR, DT and LDCT. The images
were randomly read by 3 blinded radiologists. Free-response receiver-
operating characteristic (FROC) were used to compare the differences in
detection accuracy between CR, DT and LDCT.
Results
The figures of merit for the FROC curves averaged for the observers
were 0.41, 0.37, and 0.76 for CR, DT and LDCT, respectively. FROC analyses
revealed significantly better performance (P
< 0.05) of LDCT than CR and DT
for the detection of GGO nodules. The detectability difference between CR and
DT was not statistically significant (P=0.73). The inter-observer agreements
between three readers were 0.176, 0.510 and 0.719 for CR, DT and LDCT.
Conclusion
The diagnostic performance of DT for the detection of GGO
pulmonary nodules was not significantly different to CR, and LDCT showed
significantly better performance than CR and DT. DT may not be an alternative
Method
to CT for the detection of GGO nodules, and LDCT is preferred to
detect GGO nodules.
B-0550 11:51
Trachea morphology on CTPA: correlation with extent and distribution of
adipose tissue
D. ap Dafydd, S.R. Desai, F. Gordon, S. Copley; London/UK
(
[email protected])
Purpose: Excessive expiratory tracheal collapse on CT is associated with
tracheomalacia. However, other factors such as obesity may also contribute to
this feature. We aim to evaluate the rel ationship between thoracic adiposity
and tracheal collapse in a nonselected group of patients.
Methods
and Materials: A consecutive group of non-selected patients
undergoing CT pulmonary angiograms (CTPAs) over a four-month period for
suspected pulmonary embolus were retrospectively analysed by two thoracic
radiologists. Exclusion criteria include d intubation and mediastinal masses.
Using an adapted scoring system, the morphology of the trachea was
evaluated as normal or demonstrating anterior bowing of the posterior wall to a
S254
BA C D E F G
Saturday
mild, moderate or severe degree. The cross-sectional area of the trachea at its
narrowest point was also recorded. Addi tionally, measurements of adiposity
were taken, including anterior mediastinal fat thickness, sagittal thoracic
diameter and subcutaneous fat thickness. The data was analysed using
multinomial logistical regression.
Results
296 patients were included. Both moderate and severe bowing of the
posterior trachea were significantly correlat ed with sagittal thoracic diameter
(p < 0.0001) and with mediastinal fat thickness (p < 0.005). Tracheal cross-
sectional area was inversely correlated with subcutaneous fat thickness
(p=0.005). Tracheal cross-sectional area was lower in females than in males
(p < 0.0001).
Conclusion
These findings demonstrate a statistically significant relationship
between thoracic adiposity and trachea morphology in a large nonselected
population being evaluated for pulmonary embolus. Therefore, the CT
diagnostic criteria for tracheomalacia may vary with body habitus.
10:30 - 12:00 Board Room B
Head and Neck
SS 908
Imaging techniques
Moderators:
K.S.S. Bhatia; Shatin/HK
H.B. Eggesbø; Oslo/NO
B-0551 10:30
70 kV ultra-low dose computed tomography of the paranasal sinus:
diagnostic image quality and radiation dose
B. Bodelle, B. Schulz, J.L. Wichmann, N. Klotz, T.J. Vogl;
Frankfurt a. Main/DE (
[email protected])
Purpose: To evaluate diagnostic image quality and radiation dose of 70 kV CT
low-dose technique of the paranasal sinus.
Methods
and Materials: CT of the paranasal sinus was performed on 3x40
age- and sex-matched patients at different tube voltages and currents
(70 kV/75 mAs, 100 kV/40 mAs [standard low dose protocol], 120 kV/40 mAs
[standard protocol]). CTDIvol, DLP, attenuation, image noise and SNR were
compared between the groups using Mann-Whitney U test. Subjective
diagnostic image quality was compared using a 5-point scale (1 = worst, 5 =
best, 2 readers in consensus) and Cohen's weighted kappa analysis for inter-
observer agreement.
Results
Radiation dose was significantly lower in 70 kV than 100 and 120 kV
(DLP: 32 mGycm vs. 52 mGycm vs. 82 mGycm; CTDI 2.3 mGy vs. 4.0 mGy
vs. 6.3 mGy, p < 0.05). Mean SNR (120 kV: 0.13; 100 kV 0.20; 70 kV 0.37,
p < 0.05) and organ attenuation increased statistically significantly with lower
kV, while image noise decreased (mean: 120 kV: 82 ±11 HU; 100 kV 81± 37;
70 kV 191± 26, p < 0.05). All examinations showed diagnostic image quality.
Subjective diagnostic image quality was higher in standard protocols than in
70 kV protocol (120 kV: 5.0; 100 kV 4.5; 70 kV 3.5, p 0.59).
Conclusion
70 kV ultra-low dose CT of the pa ranasal sinus allows significant
dose reduction of -61%, better attenuation of organ structures in comparison to
standard protocol while remaining diagnostic image quality with a slight
reduction in subjective image quality.
B-0553 10:39
Application of IDEAL T2- and postcontrast T1-weighted fat-suppressed
FSE imaging in head and neck at 3 T: evaluation of quality improvement
J. Hong, H. Lee, Y. Kang, M. Lim, M. Kim, S. Cho; Incheon/KR
(
[email protected])
Purpose: To compare fat-suppressed MRI quality using iterative
decomposition of water and fat with echo asymmetry and least-squares
estimation (IDEAL) with that using frequency selective fat-suppresion (FSFS)
T2- and postcontrast T1-weighted fast spin-echo images in extracranial head
and neck at 3 T.
Methods
and Materials: This prospective, single-center study was institutive
review board approved. MRI was performed in 28 individuals of a routine
patient collective. The axial T2- and postcontrast T1-weighted imaging with
IDEAL and FSFS were compared. Visual evaluation of following items was
performed by two experienced, independent readers: 1) artifacts around oral
cavity, airway, paranasal sinus, and hea d-neck junction, 2) uniformity of fat
suppression, 3) image sharpness, 4) contrast of pathologies and lymph nodes
to surrounding tissue. Statistical evaluati on was done by using the Wilconxon's
singed rank test.
Results
Both IDEAL T2- and postcontrast T1-weighted imaging significantly
reduced artifacts around airway, paranasal sinus, and head-neck junction, and
significantly improved uniform fat suppression (p < 0.05, respectively). IDEAL
significantly decreased artifacts around oral cavity on T2-weighted images, and
significantly improved lymph node-to-tissue contrast on postcontrast T1-
weighted images (p < 0.05, respectively). However, no significant improvement
was found on lesion-to-tissue contrast.
Conclusion
IDEAL T2- and postcontrast T1-weighted imaging improves
image quality by reducing the degree of artifacts around airway, paranasal
sinus, and head-neck junction, and providing uniform fat saturation of the head
and neck.
B-0554 10:48
Inner ear CT imaging: influence of iterative reconstruction techniques on
dose and image quality
F. Zanca
1, W. Coudyzer1, I. Bosmans2, A.-S. Delabie2, K. Op de beeck1,
R. Hermans1; 1Leuven/BE, 2Brussels/BE (
[email protected])
Purpose: To assess dose reduction potential using Sinogram Affirmed
Iterative Reconstruction (SAFIRE) relative to filtered backprojection (FBP) on
temporal bone computed tomography (CT).
Methods
and Materials: Two cadaver heads were scanned on 128-slice multi-
detector-row CT (SOMATOM Definition Flash) using the standard-of-care
protocol (140 kV, 220 fixed mAs) and dose reduced protocols at 200, 180 and
160 mAs (10, 20, 30% dose reduction, respectively). In addition, the standard-
of-care with lower potential (120 kV) but higher mAs (250) (30% dose
reduction) was also used. Data were reconstructed with FBP and SAFIRE
(strength 5), using very sharp filters. Objective noise and Hounsfield units were
measured in the native axial (0.4 mm slice, 0.2 mm increment) and reformatted
coronal and axial (0.8 mm slice, 1 mm increment) images. Signal to noise ratio
(SNR) was calculated and the two techniques were compared (Student t-test).
Two neuroradiologists assessed the images for visibility of ear structures and
for diagnostic image quality, using a 5- point scale (1=insufficient; 5=excellent).
Results
Objective noise was significantly lower for SAFIRE with respect to
FBP for the native images (117 ±6.6 vs 132± 8.1, p < 0.05). SNR followed the
same trend. Subjective image quality analysis was significantly better for FBP
(p-value< 0.001, SAFIRE median score 3 vs 4 for FBP).
Conclusion
Compared with FBP, SAFIRE enabled significant reduction of
Objective
image noise for the high-resolution native images which also yield a
more confident evaluation of very small structures (e.g. the ossicular chain).
However, overall image quality was significantly better for FBP, possibly
because of the extreme strength of 5 for SAFIRE.
B-0555 10:57
Reduction of MR imaging artefacts caused by cochlea implants: a
phantom study
A. Pomschar, F. Dirr, J. Müller, M.F. Reiser, B. Ertl-Wagner;
Munich/DE (
[email protected])
Purpose: To evaluate the effect of an advanced metal artefact suppression
MR sequence (warp), which combines view angle tilting (VAT), increased
bandwidth and slice-encoding metal artefact correction (SEMAC), on magnet-
induced artefacts caused by cochlea implants in an experimental setup.
Methods
and Materials: Measurements were performed on a phantom in a
3 T MRI scanner (Magnetom Skyra, Siemens Healthcare). The phantom
consisted of a plastic grid cube of 15x15x15 cm, 1 cm grid, immersed in a
copper sulphate solution with a cochlear implant, placed at 1 cm depth. 3D T1-
weighted images were acquired with and without "warp" technology, with VAT
set to 50 and 100%, respectively. Signal void penetration into the grid cube
was measured from the bottom of the CI receiver to the maximum depth of the
signal void. Signal void area around the CI receiver was measured in the plane
of the CI receiver.
Results
Signal void on T1-weighted sequences without metal artefact
suppression showed a penetration depth of 8.2 cm and an in-plane area of
167 cm². With activated "warp" technique and 50% VAT, penetration depth was
reduced by 41% to 4.8 cm and area by 72% to 47 cm², with 100% VAT, depth
was reduced by 49% to 4.2 cm and area by 76% to 40 cm².
Conclusion
An advanced metal artefact suppression algorithm combining
VAT, SEMAC and increased bandwidth significantly reduces susceptibility
artefacts caused by cochlear implants at 3 T. It has the potential to increase
the diagnostic value of cranial imaging in patients with CI.
Author Disclosures:
A. Pomschar: Equipment Support Recipient; The Syngo"warp" sequence was
provided by SIEMENS Healthcare.
S255
BA C D E F G
Saturday
B-0556 11:06
MR tractography of the intraparotid facial nerve
A. Attye, I. Troprès, A. Karkas, C. Righini, G. Bettega, A. Krainik; Grenoble/FR
Purpose: Identifying the facial nerve (VII) after the stylomastoïd foramen
remains a modern imaging challenge. We attempt to visualise the VII up the
proximal facial nerve division (FND) am ong patients admitted for parotid lesion
with diffusion tensor imaging (DTI). Then, we attempt to validate this method
by comparison with the surgeon findings.
Methods
and Materials: DTI was performed on a 3 T Philips Achieva ® MRI
Scan with a 32 channels array head coil. We used both the Philips navigational
software Fibertrack ® and free software MRtrix ® to obtain facial nerve fiber
tracking with the single Region of Interest method. The fraction of anisotropy
has been set to 0.05 and the maximal angle change to 80°. The location of the
FND in relation to the tumour was correlated with the data of the DTI during the
tumour resection by the surgeon. The correlation study included a visual
analysis and use of a monitoring of the VII (Avalanche® device).
Results
We performed a DTI study of the facial nerve among 16 patients with
focal parotid lesion before surgery. Fibres corresponding to the course of the
main trunk of the VII were identified with the DTI-based fiber tracking technique
in all patients. The visualisation of the FND allows us to define two parts of
parotid gland, superficial and deep, and to successfully locate the process into
in all cases in relation with the surgeon findings.
Conclusion
DTI study of the VII up the FND seems to be feasible and
potentially useful before management of focal parotid lesion.
B-0557 11:15
Normal variation of hypoglossal canal
M. Osawa, T. Kanda, T. Kiritoshi, K. Toyoda, H. Oba, S. Furui; Tokyo/JP
(
[email protected])
Purpose: Double hypoglossal canal and size laterality of the hypoglossal canal
are major normal variations of the canal, but the true incidences of these
variations, or sex and laterality differences are not known. We investigated the
normal variation of the hypoglossal canal using 64-slice CT and MRI.
Methods
and Materials: 596 consecutive patients (mean age, 61 years:
range, 15-94 years: 257 male, 339 female) underwent CT. 2 radiologists
independently reviewed their CT images and counted the canal number on
each side. If the canal was single, the hypoglossal canal size was measured.
61 patients who had undergone MRI, were checked for the hypoglossal nerve.
Steel-Dwass test was used, and statistical significance was established at a p-
value of < 0.05.
Results
The incidence of double hypoglossal canal was 16.9%. Right double
hypoglossal canal of women was significantly rarer than that of men or that of
the left side. Bilaterally, double hypoglossal canal was significantly rarer in
women than in men. In single hypoglossal canal patients, left side predominant
laterality was observed in 31.9% of patients and right side predominant
laterality in 12.1%. In the 61 patients who had undergone MRI the hypoglossal
verve existed within all hypoglossal canals.
Conclusion
Both double hypoglossal canal and size asymmetry of
hypoglossal canal are common. Right side double hypoglossal canal of women
was significantly rarer than that of men or that of the left side.
B-0558 11:24
Facial asymmetry and temporomandibular joint
R. Oca Pernas, E. Santos, N. Silva, A. Fernández, A. Grande, A. Bustos;
Vigo/ES (
[email protected])
Purpose: 1). To evaluate mandibular ramus length and condyle size in
patients with facial asymmetry. 2). To determine if the diagnose of facial
asymmetry is a conditioning for the development of degenerative changes in
temporomandibular joint (TMJ).
Methods
and Materials: 25 non-contrast facial CT of patients referring from
Maxillofacial Surgery Department with clinical diagnosis of facial asymmetry
were retrospectively analysed; 25 non-contrast facial CT for preoperative
assessment of unerupted molar teeth extraction were chosen as controls.
Mandibular ramus length and axial diameters (minor and major) of condyles
were measured. Degenerative changes of TMJ were evaluated independently
by two blinded radiologists with quantitative scale of 4 points (0: no
degenerative changes; 3: advanced joint destruction). In case of disagreement,
a consensus reading was conducted. Anatomic differences and degenerative
changes were analysed. Interobserver reliability was calculated.
Results
1). Short mandibular ramus length was 57.6 and 64.1 mm for patients
and controls, respectively (p=0.002). There were no statistical differences in
long mandibular ramus length between both groups. 2). Mandibular condyles
diameters, either in short or long ramus sides, were smaller in patients with
facial asymmetry (p=0.015 and p=0.013). 3). TMJs presented more severe
degenerative changes in patients (p < 0.001), being more extensive in short
ramus side condyle (p=0.014). 4). Interobserver reliability was 0.84 and 0.86
for long and short ramus sides.
Conclusion
1). Patients with facial asymmetry show shorter mandibular
ramus length and smaller condyles. 2). TMJ degenerative changes are more
severe in patients with facial asymmetry, mainly in short mandibular ramus
side.
B-0559 11:33
Mandibular incisive canal (MIC): visibility and path of the intramandibular
course using cone beam computed tomography (CBCT)
D. Di Salvo, A. Borghesi, R. Bettini, D. Farina, R. Maroldi; Brescia/IT
(
[email protected])
Purpose: The interforaminal mandibular region is considered a safe zone for
implant surgery; nevertheless literature reports neurosensory disturbances of
the lower lip from 7% to 24% of cases after implant placement in this area. The
aim of this retrospective study was to assess the visibility and path of
intramandibular course of MIC using CBCT.
Methods
and Materials: 140 patients (280 hemimandibles) were included in
this study. The visibility, diameters and distances from anatomical landmarks in
the interforaminal region (root tips, buccal , lingual and inferior cortex of the
mandible) were measured twice by two observers using CBCT in consensus.
Coefficient of repeatability (CR) and limits of agreement were calculated by
Bland-Altman method.
Results
CBCT identified MIC at root tips of first premolars, canines and lateral
incisors in 70%, 46.1% and 15.4%, respectively. At the same landmarks, the
mean diameters were 1.4 mm, 1.1 mm and 0.9 mm (CR range: 0.4-0.6 mm);
the mean distances from the root tips were 5.7 mm, 6.3 mm and 8 mm (CR
range: 0.7-1.2 mm); the mean distances from buccal cortex were 3.0 mm,
5.0 mm and 5.1 mm (CR range: 0.7-1.2 mm); the mean distances from lingual
cortex were 5.3 mm, 4.6 mm and 4.9 mm (CR range: 0.5-0.9 mm).
Conclusion
Even though the MIC is usually only partially corticalised,
therefore difficult to trace in some cases, the variability of measurements of
MIC using CBCT was reasonably small, with the potential to improve the
precision of implant surgery planning in the interforaminal region.
B-0560 11:42
Quality assurance of dental digital imaging in Finland in health care
facilities having CBCT devices
E. Metsala, K. Holopainen, T. Parviainen; Helsinki/FI
(
[email protected])
Purpose: In October 2011, Radiation and Nuclear Safety Authority Finland
published a guide presenting the radiation safety requirements concerning
dental x-ray practices and quality assurance procedures. The aim of this study
was to describe dental x-ray quality assurance procedures performed in
Finland, and dental imaging staff's educational needs associated to them.
Methods
and Materials: Target group of the study was all the health care
organisations in Finland having the cone beam CT in their use. The data were
collected by a postal questionnaire during spring 2012 and 25/33
questionnaires were returned. The questionnaire comprised 39 questions, out
of which ten were open-ended, 23 structured and 6 half-structured questions.
The data were analysed by using PASW Statistics 18 program.
Results
Dental health care quality assurance tests were well performed. The
most common quality assurance tests were mechanical and an emergency
switch tests. Almost all the respondents (22/25) had received some kind of life-
long education in dental digital imagi ng quality assurance (QA). However, only
11 of them had received QA-education during their professional education.
Participators wanted continuous and regular training. They also wished
revision to basic radiation protection and pr actical training. There came also up
a wish for cone beam CT training for dental hygienists.
Conclusion
State of quality assurance in dental digital imaging in Finland is
quite good. However, education of the topic is still needed. Most urgently is
needed education for the basic radiation protection issues and cone beam
imaging quality assurance issues.
S256
BA C D E F G
Saturday
10:30 - 12:00 Room E1
Musculoskeletal
SS 910
Tumours
Moderators:
T. Bäuerle; Erlangen/DE
J.L. Bloem; Leiden/NL
B-0561 10:30
Does apparent diffusion coefficient values can be used for the
differentiation of small-blue-round cell tumours from malignant non-
small-blue-round cell tumours?
F.B. Ergen, G. Yildirim, I.C. Kose, J. Karakaya, B. Aydin, U. Aydingoz;
Ankara/TR (
[email protected])
Purpose: The purpose of this study is to assess the ability of apparent
diffusion coefficient (ADC) values in differentiating small-blue-round cell
tumours (SBRCT) and malignant non-small-blue-round cell tumours (NSBRCT)
of the musculoskletal system.
Methods
and Materials: For a period of 1.5 years, patients presented with
SBRCT (n=10) and NSBRCT (n=8) who underwent conventional MRI and
diffusion-weighted imaging (DWI) were included to this study. None had
received anti-neoplastic therapy and all were pathologically confirmed. For
each mass, two observers independently measured 3 different ADC values
from the areas that demonstrate the lowest diffusivity. The difference between
the medians of SBRCT and NSBRCT was assessed with Mann-Whitney test.
The optimal cut-off ADC value was determined with ROC analysis.
Results
Eighteen patients (mean age, 54 years) with final diagnosis of
Ewing's sarcoma (n=7), Langerhans cell histiocytosis (n=2) multiple myeloma
(n=1), PNET (n=1), osteosarcoma (n=4), mixoid liposarcoma (n=2),
chondrosarcoma (n=1), were included. Median ADC values of SBRCT and
NSBRCT were 0.57±0.18x10
-3 and 1.03±0.61x10-3 mm2/sec for observer 1; and
0.55 ±0.19x10-3 and 1.04± 0.58x10-3 mm2/sec for observer 2, respectively. We
found a statistically significant differ ence between the median ADC values for
both observers ( P=0.006). Intraclass correlation coefficient was 94% (95% CI,
86.5%-98.0%). The area under ADC ROC curve was 0.88 (95% CI, 0.64-0.98).
The optimal cut-off point was 0.69 x10 -3 mm2/sec. For this cut-off point,
sensitivity and specificity were 85.7% and 81.8%, respectively.
Conclusion
Apparent diffusion coefficient values can be used in
differentiation of SBRCT from malignant NSBRCT in patients with
musculoskeletal tumours.
B-0562 10:39
Imaging follow-up of large and symptomatic soft tissue lipomas
R. Balasubramaniam, H. Lyall, H. Gupta, P. Robinson; Leeds/UK
(
[email protected])
Purpose: Lipomas > 5 cm, below deep fascia or symptomatic have malignant
potential and UK national recommendati ons are for excision. However patient
reluctance and anatomical location can make surgery unattractive. We
prospectively studied patient outcomes for lipomas referred to a sarcoma
service for surgery but managed conservatively.
Methods
and Materials: Prospective series of 80 patients referred to a
sarcoma service with lipomas > 5 cm, deep to fascia, symptomatic and/or
minor atypical imaging features initially managed conservatively. All lesions
measured and interval growth defined as percentage increase from initial
dimensions. Minor atypical imaging features defined as internal septal
thickening/blood flow, heterogenous echo genicity on ultrasound or mild
incomplete MRI fat suppression (not nodular). Clinical follow-up and imaging
surveillance was performed.
Results
26 lipomas were subcutaneous, 10 intra-fascial, 12 inter-muscular
and 32 intra-muscular. Conservative management occurred because: location
(20), co-morbidity (3), pregnancy (1), and patient choice (56). At presentation
80 had ultrasound and 59 MRI. 8/59 had MRI atypical features (8 incomplete
fat suppression, 2 septal enhancement) and another 8/80 ultrasound atypical
features (septation low blood flow or thickening). 46 were > 5 cm on MRI and
54 on ultrasound. Mean follow-up was 12 months (range 8-32). No lesions with
atypical imaging showed significant interval growth. 9 lesions showing interval
growth (range 7.1- 56%) all demonstrated stability on at least one subsequent
scan and 3 cases underwent surgery with histology and cytogenetics
confirming lipoma.
Conclusion
This study demonstrates that large, deep or symptomatic lipomas
where surgery is not immediately indicated can be safely followed up with
MRI/Ultrasound.
B-0563 10:48
Frequency of MR parameters in soft tissue synovial sarcoma:
comparison between different histopathologic type
V. Vasilevska Nikodinovska1, K. Vilanova2, F.M.H.M. Vanhoenacker3,
I.-M. Nöbauer-Huhmann4; 1Skopje/MK, 2Girona/ES, 3Brussel/BE, 4Vienna/AT
(
[email protected])
Purpose: To evaluate the frequency of the magnetic imaging (MRI)
parameters in synovial sarcoma. To assess the correlations between MRI
parameters and histopathological types of synovial sarcoma, as well as to
select specific MRI parameters that could possibly predict the histological type
of synovial sarcomas.
Methods
and Materials: MRI findings of 43 cases (23 males, 20 females,
median age 40 years) of synovial sarcoma of the soft tissue were
retrospectively analysed. Monophasic was 24 cases (56%), biphasic
17 (39.5%) cases and two were low differentiated synovial sarcomas. Twenty-
four MRI parameters were evaluated. Besides descriptive statistics, Spearman
rank-order correlations, Mann-Whitney U test and Multivariate regression
analysis were performed.
Results
Deep and extracompartmental localisations were found in 79% of the
cases. Most of the cases were with iso signal intensity (SI) in T1 and high and
inhomogeneous SI in T2, with peripheral (53%) and inhomogeneous (88%)
enhancement. Both cystic areas and necrosis were present in 53%. Mostly,
haemorrhage and fluid-fluid levels were absent. Multilocular configuration was
observed in 12 (28%) cases. Sixty three percent of the cases had well-
demarcated margins, and in the same percentage two different solid areas
were present. Bone and joint involvement was rare. Multiple regression
analysis showed that there were no MR parameters significantly predictive for
the histopathological type of synovial sarcomas. There were no statistically
significant differences between th e monophasic and biphasic synovial
sarcomas for none of the evaluated parameters.
Conclusion
Evaluated MR parameters cannot reliably predict the
histopathologic types of synovial sarcoma.
B-0564 10:57
Myxoid containing tumours of soft tissues: MRI appearance with
radiologic-pathologic correlation
N. Alberti, X. Buy, N. Frulio, M. Kind; Bordeaux/FR (
[email protected])
Purpose: To identify specific MRI features and to correlate with pathology in a
large series of histologically proven myxoid soft tissue tumours (STT).
Methods
and Materials: 63 patients with myxoid STT were included. All
patients underwent MRI before surgery. Definite histological diagnosis was
obtained after surgical resection in all cases. Following criteria were analysed:
before contrast injection: tumour location relative to the fascia, lesion margin,
signal homogeneity, peritumoural oedema; presence of hyperintense T1 WI
peripheral rim (fat split sign). After contrast injection: tumour enhancement;
presence of tail sign. Correlation with pathology focused on: T2WI fluid-like or
hypo-intensity areas compared to myxoid, necrotic and fibrotic tissue; loss of
hyper-T1 signal on fat-sat sequence compared to adipose tissue.
Results
Histopathology was low-grade fibromyxoid sarcoma (LGFMS),
myxofibrosarcoma (MFS), myxoid liposarcoma (MLPS), and myxoma in 8, 23,
20 and 12 cases, respectively. All myxoma and LGFMS were intramuscular
while all MLPS were intermuscular. 75% MFS invaded both fascial and deep
structures. ͒ Myxoid matrix was found in 75% MLPS and 90% myxoma;
LGFMS and MFS showed heterogeneous mild T2 signal with fibrous tissue at
histology. When present, fatty T1 hypersignal was specific of MLPS and tail
sign specific of MFS.
Conclusion
Myxoid STT are a heterogeneous group of mesenchymal
tumours with characteristic imaging features. MR results give the basis of
decision-making by a multidisciplinary committee.
B-0565 11:06
Assessment of the preoperative chemotherapy of soft tissue sarcomas
using anatomical and functional methods of visualisation
Y. Zamogilnaya, N. Kochergina, A. Bludov, A. Nered; Moscow/RU
(
[email protected])
Purpose: To increase and compare the informativeness of MRI, changes in
tumor size and DCE-MRI in assessment of the preoperative chemotherapy of
soft tissue sarcomas (STS) by developing differential criteria (decisive rule -
DR) of poor and good response (PR/GR) to treatment.
Methods
and Materials: To develop the DR for different methods of
visualisation 74 patients with STS were analysed (74 with MRI, 37 with DCE-
MRI). Plus MRI was used to estimate the changes in the tumor size according
to RECIST criteria. The DR was created using multifactor analysis whereby
statistically significant radiological si gns acquired weight coefficients (WC),
S257
BA C D E F G
Saturday
which determined the frequency of occurrence of symptoms in a group of
patients with GR and PR.
Results
The sensitivity of DR for MRI was 65%, the specificity - 86%; for
DCE-MRI - 100% and 84%, of RECIST criteria - 50% and 100%, respectively.
The most informative MRI and DCE-MRI signs with the highest WC were:
decrease of a proposed solid component, increase of the thickness of
pseudocapsule and disappearance of enhancement, type II of the curve of the
tumor for GR; increase/appearance of cystic component, preservation of
surrounding edema and diffuse type of enhancement, type V of the curve of
the tumor for PR.
Conclusion
MRI (qualitative and RECIST criteria) with its higher specificity
better predicts PR, DCE-MRI shows higher values of sensitivity associated with
GR. The combination of anatomical and functional methods improves the
quality of evaluation of the treatment in patients with STS (sensitivity - 100%,
specificity - 96%).
B-0566 11:15
Pilomatricoma: radiologic findings of 17 cases
Y. Hirokawa1, H. Kurokawa1, S. Ikeda1, R. Terasawa1, M. Kohzai1, T. Tsuno1,
K. Ikeda2, N. Sakaida1, N. Tanigawa1; 1Shinmachi/JP, 2Moriguchi/JP
(
[email protected])
Purpose: The purpose of this study is to ev aluate the characteristic findings of
pilomatricoma on x-ray, CT, and MRI and to correlate the imaging findings with
histopathologic features.
Methods
and Materials: We retrospectively reviewed X-ray (n=3), CT (n=8),
and MR (n=8) findings of 17 cases in 171 consecutive patients pathologically
confirmed pilomatricomas during 2006-2012. The radiologic findings of various
tissues within tumours were evaluated by x-ray, CT, and MRI. The study
population included 10 men and 7 women with a mean age of 27.3 years
(range 2-94 years). The lesions were located in the subcutaneous fat layer of
the head and neck (n=9), extremity (n=8). Imaging findings of all cases were
compared with histopathologic findings.
Results
On MRI, in all cases, tumours showed isointensity compared with
adjacent skeletal muscle on T1, T2WI. But on T2WI, 6 of 8 cases showed
various degree of reticular and/or patchy hyperintense area. On CT, 6 of 8
cases showed isodensity compared with skeletal muscle. Four cases
combined low-density areas, partially . Seven of 8 cases had combined
calcification. Four cases showed fine and other 3 cases showed coarse
nodular calcification. In comparison with pa thologic finding, isointensity areas
on T1, T2WI and iso- or high-density areas on CT compared with skeletal
muscle were corresponding to intercellular cement, granulation, fibrosis and
calcifications. And low-density areas on CT and reticular and amorphous high-
intensity areas on T2WI were corresponding to basaloid cells and ghost cells
within tumour.
Conclusion
Radiologic findings of pilomatricoma have some characteristic
findings which are fine and/or spotted cal cifications (X-ray, CT)and isointensity
compared with skeletal muscle combined funi cular or reticular high-intensity
area (T2WI). These findings were useful for differential diagnosis.
B-0567 11:24
Neurovascular invasion by soft-tissue sarcoma: assessment with MR
imaging in 174 cases
K. Holzapfel, J. Regler, H. Rechl, K. Specht, R. von Eisenhart-Rothe,
R. Gradinger, E.J. Rummeny, K. Wörtler;
Munich/DE (
[email protected])
Purpose: To evaluate MR imaging in the assessment of neurovascular
invasion by soft-tissue sarcoma.
Methods
and Materials: MR images of 174 patients with soft-tissue sarcoma
who subsequently underwent resection/amputation were analysed by two
readers. To assess neurovascular invasion, extent of contact between tumour
and neurovascular structures was classified using a five-point scale (no
contact, contact 90°, 91-180°, 181-270°, > 271°). Interobserver agreement in
quantifying contact between tumour and neurovascular structures was
calculated using kappa coefficients. Imaging findings were correlated with
intraoperative findings and/or results of histopathology. ROC analysis was
performed to determine the optimal threshold value to predict neurovascular
invasion.
Results
Intraoperative evaluation/histopathology confirmed neurovascular
invasion in 25.3% of patients. Interobserver agreement in quantifying contact
between tumour and neurovascular structures was excellent for arteries, veins
and nerves (kappa: 0.85/0.89/0.89). ROC analysis revealed an optimal
threshold value of > 180° for the prediction of arterial, venous and neural
Invasion for Reader1 and for arterial and venous invasion for Reader2,
whereas the threshold value for nerves was > 270° for Reader2. Using these
cut-off values, sensitivities/specificities in diagnosing invasion of arteries, veins
and nerves were 84.6%/97.5%, 84.6%/97.5% and 77.8%/93.2% for Reader1
and 84.6%/93.8%, 84.6%/94.7% and 72.2%/97.3% for Reader2. The areas
under the ROC curves for arteries, veins and nerves were 0.95/0.95/0.93
(Reader1) and 0.95/0.96/0.92 (Reader2).
Conclusion
MR imaging allows reliable and accurate assessment of
neurovascular invasion by soft-tissue sarcoma. Neurovascular invasion should
be diagnosed, if contact between tumour and vascular/neural circumference
exceeds 180°.
B-0568 11:33
Ultrasound-guided biopsy in bone lesions: how and when it can be done.
Preliminary results
S. Pozza
1, A. De Marchi1, M. Boffano1, G. Biino2, R. Piana1, C. Faletti1;
1Turin/IT, 2Pavia/IT (
[email protected])
Purpose: Bone biopsy is usually under CT guidance. The aim of this study is
to propose US guided biopsy in specified bone lesions with cortex interruption
but without soft tissue involvement.
Methods
and Materials: From January 2012 to February 2013, thirteen
patients underwent an US guided biopsy for a bone lesion. The lesions, always
characterised by a cortex interruption, were located in the lower limb (3 cases),
in the upper limb (4), in the chest (3), and in the pelvis (3). To assess the
diagnostic accuracy we evaluated agreement between the diagnosis made on
bone tissue specimens from needle biopsy and either the final diagnosis or the
clinical evolution (whether not further surgically treated) by means of Cohen's
kappa. This coefficient is a statistical measure of inter-rater agreement for
categorical items.
Results
In 10 cases out of 13 the diagnosis was obtained correctly. The
diagnosis were myeloma (3 cases), metastases of carcinoma (3), metastases
of sarcoma (1), giant cell of the bone (2), Tietze's disease (1), not diagnostic
biopsy (3). On 13 patients 5 tumors types were diagnosed, so that 5 items
were considered for Kappa coefficient cal culation. In three patients insufficient
Material
was obtained to allow a histological diagnosis. In the remainder 10
patients a perfect agreement was observed (k=1, p < 0.05).
Conclusion
In accurately selected cases the biopsy of bone lesions can be
performed under US guide. This technique is eventually more time effective
and does not use ionising radiation. Fu rther studies are needed to confirm our
results.
B-0569 11:42
Magnetic resonance guided focused ultrasound surgery for osteoid
osteoma
A. Bazzocchi1, A. Napoli2, P. Spinnato1, D. Diano1, G. Facchini1, M. Busacca1,
C. Catalano2, U. Albisinni1; 1Bologna/IT, 2Rome/IT (
[email protected])
Purpose: This work presents the six months after and the preliminary
experience in the treatment of osteoid osteoma by magnetic resonance guided
focused ultrasound surgery (MRgFUS), at the Rizzoli Institute.
Methods
and Materials: Six patients affected by osteoid osteoma were
treated by MRgFUS (ExAblate 2100, InSightec, Israel on 1.5 T Signa Twin
Speed MR-system, GE, USA), and were followed at 1, 3, and 6 months after
the procedure. Only osteoid osteomas with typical presentation, according to
clinical and imaging findings, were recruited. Pain and function were scored
before and after MRgFUS.
Results
Patients were all males, ageing 18-46 years old (BMI 26.2 ±4.9, range
19.3-34.5 Kg/m2) and presented with pain scoring 5 to 10 on a visual analogue
scale basis [VAS - 0-10 scale]). All osteoid osteomas were located at femur
(head/neck in 4, diaphysis in 2), and in one case a recurrence after
radiofrequency ablation was treated. No intra- and post-procedure
complications or adverse effects were observed. VAS immediately dropped to
2.3±1.6 (0-5, at discharge) (p < 0.001), and flattened to 0 in all patients from
the 1-month check. At 6 months, no pain or function limitations were present.
Conclusion
MRgFUS is safe, and extremely effective in the treatment of
osteoid osteoma. This interventional procedure pushes the front of treatment to
an even less invasive approach, and this may represent a true competitor of
any other method in today's clinical management of osteoid osteoma.
B-0570 11:51
MRgHIFU treatment in pain palliation of bone metastases: initial
experience from the Rizzoli orthopaedic institute
A. Bazzocchi
1, A. Napoli2, P. Spinnato1, F. Ponti1, M. Busacca1, C. Catalano2,
U. Albisinni1; 1Bologna/IT, 2Rome/IT (
[email protected])
Purpose: Bone metastases are the most common cause of cancer-related
pain. The aim of this work was to assess the efficacy of MRgHIFU in the
treatment of pain caused by bone metastases, in the preliminary cohort of
patients treated at our Institute.
Methods
and Materials: From November 2012, 16 patients affected by bone
metastases were enrolled in the study. Pain and quality of life were scored
before and after MRgHIFU (ExAblate 2100, InSightec, Israel on 1.5 T Signa
Twin Speed MR-system, GE, USA). A clinical follow-up was performed at 1, 3
and 5 months.
Results
Twenty lesions were treated in 16 patients (7 males, 9 females, age
range 47-83 years) with different primary cancers (4 breast, 4 kidney, 3 lung, 3
S258
BA C D E F G
Saturday
thyroid, 1 colon, 1 rectum). The treated lesions were located as follows: 17 at
pelvis (85%), 2 at femur, 1 at rib. In five patients the bone lesion was single.
Treatments were performed under spinal anesthesia in 14/16 patients, under
general anesthesia in 2/16. Two patients died during the follow-up
(approximately 2 months after the treatment), while ten patients reached the 3-
month check point, and five the 5-month one. According to visual analogue
scale (VAS, 0-10 points) results, the average pain drop after 1 month
amounted to 57%, and this was 86% at both 3 and 5 months from baseline (all
p
< 0.01), with 3 out of 5 patients presenting VAS=0.
Conclusion
Our preliminary experience shows the efficacy and the safety of
MRgFUS in controlling the pain of bone metastases from different primary
cancers.
10:30 - 12:00 Room F1
Oncologic Imaging
SS 916
Emerging applications of diffusion-
weighted MRI
Moderators:
A. Luna; Jaen/ES
M.C. Roethke; Heidelberg/DE
B-0571 10:30
Is whole-body diffusion-weighted imaging all we need for detecting
metastases in melanoma patients?
G. Conte, G. Petralia, P. Summers, S. Alessi, A. Testori, M. Bellomi; Milan/IT
(
[email protected])
Purpose: To investigate whether whole-body diffusion-weighted imaging (WB-
DWI) is adequate for detecting metastases in melanoma patients or must be
combined with contrast-enhanced WB magnetic resonance imaging (ceWB-
MRI).
Methods
and Materials: One-hundred and forty-seven WB-DWI and ceWB-
MRI studies were performed quarterly in 23 patients with advanced melanoma.
The reference standard was biopsy, other imaging, or changes on follow-up.
Findings of metastasis in separate WB-DWI and WB-DWI+ceWB-MRI readings
were compared using 5 statistics.
Results
Eleven patients were metastatic by reference standard. At reading,
14 patients were considered positive and 9 negative for metastases by WB-
DWI: 9 proved to be TP, 5 FP, 7 TN and 2 FN. Fifteen patients were
considered positive and 8 negative for metastases by WB-DWI+ceWB-MRI: 10
TP 5 FP, 7 TN and 1 FN. Both techniques failed to detect the presence of
metastasis in a patient with local recurrence, and WB-DWI failed in one with
case of brain metastasis. There was almost perfect agreement between
techniques for detection of patients with metastases ( 5M=M93.7 %, 95 % CI 81.5-
100 %). A total of 21 metastatic findings were observed by reference standard,
of which 16 were detected using WB-DWI (16 TP, 5 FN, 6 FP), and 19 using
WB-DWI+ceWB-MRI (19 TP, 2 FN, 12 FP). Both techniques failed to detect a
lung metastasis and a local recurrence, and WB-DWI did not detect three brain
metastases.
Conclusion
WB-DWI without additional WB-ceMRI sequences is promising
for detecting extracranial metastases in melanoma patients, but contrast-
enhanced MRI is required for brain evaluation.
B-0572 10:39
Possibilities of diffusion-weighted magnetic resonance imaging in
detection of peritoneal dissemination in case of recurrent ovarian cancer
I. Sychenkova, N. Rubtsova; Moscow/RU (
[email protected])
Purpose: To determine the possibilities of DWI MRI in detection of
dissemination on the peritoneum of abdomen and pelvis in patients with
ovarian cancer, who underwent specialised antineoplastic therapy, with the
presence of recurrence according to the results of oncomarker test.
Methods
and Materials: The study included 28 female patients (age range: 41
to 69 years) with the presence of recurrence according to the results of
oncomarker test. All the patients underwent MRI, whose data were
subsequently compared with the histopathological examination of remote
specimens. MRI was performed in two stages: the first one was carried out with
the use of a protocol that included Sg T2, Ax T2, Cor T2 FatSat, Obl-Ax T2,
Obl-Cor T2 and Co T1; the 2
nd - with addition of DWI MRI to the standard
protocol.
Results
The indicators of MRI diagnosti c effectiveness when using the
standard protocol were the following: accuracy 50%, sensitivity 48%, and
specificity 66%. The informativity measures when using the DWI MRI method
increased to: 92% for accuracy, 93% for sensitivity and 100% for specificity.
Conclusion
The use of DW MRI significantly increases the diagnostic
efficiency measures of the technique in the diagnosis of recurrent ovarian
cancer. Considering the high technique informativity, it is recommended to be
obligatory included into the examination protocol for monitoring of patients,
who underwent specialised antitumour treatment for ovarian cancer.
B-0573 10:48
To analyse whether values of ADC have a correlation with survival and
with epidermal growth factor receptor amplification in glioblastoma
R. Zalazar, M. Paramo, M. Hernandez, j. Etxano, P. Garcia Barquin,
P. Dominguez, H. Quiceno Arias, E. Guillen, M. Garcia de Eulate;
Pamplona/ES (
[email protected])
Purpose: To analyse whether values of appar ent diffusion coefficient (ADC)
have a correlation with survival and with epidermal growth factor receptor
(EGFR) amplification in glioblastoma (GBM).
Methods
and Materials: 49 patients with untreated GBM were analysed and
underwent a diffusion-weighted imaging study before surgery (mean=6 days).
Mean follow-up (18.69 months-DS ± 10.3). A ROI was drawn on ADC map in
the highest restriction region of the tumor and on the normal-appearing
contralateral white matter (NCWM). ADC-min values were evaluated as well as
ADC-index defined as a ratio between tumoral ADC-min and NCWM-ADC
mean. EGFR amplification, tumoral volume, residual volume, progression-free
survival (PFS) and overall survival (OS) were analysed. Student t test, reciever
operating curves (ROC), Kaplan-Meier and Cox regression model were
performed.
Results
30 patients had EGFR unamplified. 39 patients had complete
resection. Presurgical tumoral volume (mean=42.1 cm 3) and postsurgical
volume (mean=0.65 cm 3) had no association with survival. Both ADC-values
and ADC-index were not related with EGFR amplification. On Kaplan-Meier
analyses, EGFR amplification was correlated better with a decrease in PFS
(p=0.029), while ADC-index > 0.7 correlates better with OS ( p < 0.001). EGFR-
unamplifided patients with ADC-index < 0.7 had a significant decrease in PFS
(p=0.002) and OS ( p 0.7 had better OS than patients with ADC-index < 0.7 (p=0.028), without
differences in PFS. The ADC-index value of 0.7 represents the best cut-off
value for predicting OS. ADC-index was a significant predictor variable on Cox
regression model (p=0.024).
Conclusion
The EGFR amplification is significantly correlated with PFS, while
ADC-index condition OS in GBM. EGFR and ADC-index could be strong
pretreatment predictors of survival in patients with GBM.
B-0574 10:57
Predicting treatment response in lymphoma: value of pretreatment
apparent diffusion coefficient and its early change during chemotherapy
S.A. Kharuzhyk, N.V. Sachivko; Minsk/BY (
[email protected])
Purpose: To evaluate usefulness of pretreatment apparent diffusion coefficient
(ADC) and its early change during chemotherapy to predict treatment response
in lymphoma.
Methods
and Materials: Whole body MRI with diffusion weighted imaging
(b=0 and 800 s/mm 2) was performed in 19 patients (26-76 years) with
morphologically confirmed lymphoma before treatment and repeated at the
level of target lesion (largest lymph node) after first, before and after second
cycles of chemotherapy. ADC was measured on three adjacent slices and
averaged to get target lesion ADC. Tumors were considered responding to
treatment if product of two maximal perpendicular diameters decreased by
more than 50%.
Results
Pretreatment ADC was equal to 0.99×10 -3 mm2/c and increased by
47%, 74% and 88% after first, before and after second cycles of
chemotherapy. Product of tumor diameters before treatment was equal to
3089 mm
2 and decrease by 43%, 47% and 74% correspondingly. There was a
positive correlation between pretreatment ADC and residual tumor size after
first (r = 0.47, p = 0.057), before (r = 0.51, p < 0.03) and after second (r = 0.60,
p < 0.01) cycles. In ROC-analysis pretreatment ADC cut-off of 0.69×10 -3 mm2/c
predicted tumor response after first cycle of chemotherapy with 50% sensitivity
and 82% specificity (Az=0.63). Pretreatment ADC cut-off of 0.82×10 -3 mm2/c
predicted tumor response after second cycle of chemotherapy with 60%
sensitivity and 100% specificity (Az=0.85).
Conclusion
ADC increases early during treatment in parallel and does not
precede decrease in tumor size. Pretreatment ADC can predict tumor
response after second cycle of chemotherapy.
S259
BA C D E F G
Saturday
B-0575 11:06
Diffusion-weighted MR imaging and volume measurements in
assessment of early tumour response to antiangiogenic therapy
M.J. Schneider, K. Nikolaou, C. Cyran, M.F. Reiser, O. Dietrich;
Munich/DE (
[email protected])
Purpose: To evaluate the combination of DW-MRI and volume measurements
to classify placebo and therapy group in an experimental tumour model.
Methods
and Materials: In 23 athymic nude rats, human colon carcinoma
xenografts (HT-29) were implanted in the left flank. Animals were examined
before and 7 days after treatment onset with regorafenib (n=12) or placebo
(n=11) in a 3-Tesla whole-body system. For DW-MRI, a single-shot EPI
sequence with 0.5×0.5×2 mm³ resolution and 9 b-values (10-800s/mm²) was
used. The apparent diffusion coefficient (ADC) was calculated voxelwise by
monoexponential fitting. Multi-slice regions of interest were defined covering
the entire tumour, within which the median was taken as representative tumour
ADC. Tumor volume was determined using a T2-weighted turbo-spin-echo
sequence with 0.3×0.3×1.5 mm³ resolution and TR/TE=9560/91 ms. Observed
absolute ADC and relative volume changes between first and second
measurement were evaluated as classifiers by a receiver-operator-
characteristic (ROC) analysis individually, followed by a Fisher's linear
discriminant analysis (FLDA) combining both parameters.
Results
Sensitivity, specificity, and accuracy of the ADC-based ROC analysis
were 0.875, 0.636, and 0.783, respectively (ADC-change cutoff:
0.033 mm²/10³s, above=therapy), and for the volume 0.818, 0.818, and 0.826,
respectively (volume-change cutoff: 61.4%, below=therapy). The combined
FLDA approach yielded a sensitivity of 0.833, specificity of 1 and accuracy of
0.913.
Conclusion
The combination of both parameters slightly decreased the
sensitivity compared to using ADC alone; however, a considerable increase in
specificity was achieved resulting in the highest diagnostic accuracy, thus
outperforming the use of either ADC or tumour volume individually in the
differentiation of therapy vs. placebo group.
B-0576 11:15
Comparison between ADC and extravascular extracellular volume in
oncologic patients under chemio-radiotherapy: preliminary results
L. Natale
1, C. Biagini2, M. Betti2, C. Biagini2, G. Izzo1, L. Cionini2; 1Rome/IT,
2Sesto Fiorentino/IT (
[email protected])
Purpose: To compare the apparent diffusion coefficient (ADC) changes,
obtained by diffusion-weighted imaging (DWI) with the extravascular
extracellular volume (Vee) changes, obtained by T1 perfusion imaging (DCE-
MRI), in patients receiving chemo-radiotherapy. The rationale lies in the
common micro-biological interpretation of both parameters, the tissue "cell
density". Consequently, their change, obtained simultaneously with
independent methods, should correlate positively and linearly, within the
experimental errors.
Methods
and Materials: 12 consecutive patients with different tumours
underwent a baseline MRI and a second MRI after two weeks from the
beginning of the therapy, for early assessment of treatment efficacy. An
experienced radiologist contoured a region of interest (ROI) on DWI images to
localise the lesion and to obtain the mean ADC value. After a post-processing
with dedicated software (Tissue4D, Siemens HealthCare, Erlangen), the same
operator contoured a ROI on the considered lesion in DCE-MRI to obtain the
mean Vee value. The relative variation of the two parameters, calculated as
(X2weeks - Xbaseline)/Xbaseline was plotted.
Results
Our measurements, although strongly affected by experimental error,
demonstrate an evident correlation between ADC and Vee: the variations of
both parameters show a positive and linear behaviour for almost all of the
patients under study. Only in patients with prostate cancer, the variations of
ADC and Vee seem not follow any correlation.
Conclusion
ADC and Vee changes after chemo-radiotherapy appear to be
closely related, confirming their depende nce on cellular density, except in
patients with prostate cancer in which a new interpretative paradigm seems to
be necessary.
B-0577 11:24
The role of DWI as a marker of prediction of tumour grade in endometrial
cancer: preliminary results
C.L. Piccolo, R. Del Vescovo, A. Ramaglia, E. Schena, F. Giurazza,
R.F. Grasso, B. Beomonte Zobel; Rome/IT (
[email protected])
Purpose: To evaluate the effectiveness of diffusion-weighted MRI (DW-MRI) in
the assessment of tumour grade in endometrial lesions.
Methods
and Materials: 54 endometrial lesions including 27 endometrial
cancers and 27 benign lesions were enrolled in our prospective study. DWI
was performed with b factors values of 0, 500, and 1000 s/mm -2. The region of
interest was defined within the tumor on T2-weighted EPI image and then
manually copied to an apparent diffusion coefficient (ADC) map. Then, the
ADC value was obtained and the calculation of mean ADC value was
correlated with histology.
Results
The mean ADC values for histological grade 1 and 2 were 0.79 x10
-
3 mm2s-1 and 0.73 x10 -3 mm2s-1 for grade 3 endometrial lesions. There was no
statistically significant difference between tumour grades. The mean ADC
value for endometrial carcinoma (grouping all types of tumors) was significantly
lower (p < 0.01) than that of benign endometrial lesions. A cut-off mean ADC
value of less than 1.01 x10 -3 mm2s-1 yielded a sensitivity, specificity and
accuracy of 89.3%, 87.5% and 88.8% respectively.
Conclusion
ADC measurements can quantitatively differentiate between
benign and malignant endometrial lesions. However, tumor mean ADC is not
useful in the assessment of tumor grade.
B-0578 11:33
DW-MRI for the characterisation of focal liver lesions in cancer patients
R. Chojniak, M.L. Testa, L.S. Sene; São Paulo/BR
(
[email protected])
Purpose: Most studies accessing the ability of DWI-MR to differentiate benign
and malignant liver lesions included cysts in the analysis. Cysts are easy to
diagnose and have high ADC values what increases diagnostic accuracy of
such studies. Comparison of the ADC values obtained for cysts, solid benign
and metastatic liver lesions in cancer patients is presented.
Methods
and Materials: ADC values of 325 liver lesions in 115 adult cancer
patients were prospectively analysed. Lesions were diagnosed throughout
imaging and clinical characteristics. On e hundred and five benign (42 cysts, 63
solid benign) in 57 patients and 262 metastatic lesions in 58 patients were
included. ADCs were obtained with 0.600 sec/mm² b values. ROC analysis
was conducted to evaluate ADC performance for metastasis diagnosis.
Results
The mean ADC values were 2.3, 1.4 and 1.1 x 10-3 mm²/sec for
cysts, solid benign and metastatic lesions. Benign and metastatic lesions
ADCs' were different when cysts were included (p < 0.0001) but not when only
solid benign lesions were analysed (p=0.10). The ADC cutoff value of 1.3 x 10-
3 mm²/sec differentiates benign solid and metastatic lesions with an accuracy
of 66%.
Conclusion
In cancer patients, ADC value cannot confidently differentiate
solid benign and metastatic liver lesions. Most studies that suggest that
application included cystic lesions in the evaluation and must have the results
analysed with caution.
B-0579 11:42
Correlation between DWI-ADC values and histological cellularity in bone
marrow biopsy in patients affected by lymphoma
S. Carbone, I. Grazzini, A. Fausto, L. Leoncini, M. Mazzei, L. Volterrani;
Siena/IT (
[email protected])
Purpose: To investigate the relationship between crest bone marrow apparent
diffusion coefficient (ADC) and cellularity percentage obtained by bone marrow
biopsy (BMB) in a population of patients affected by lymphoma scheduled for
whole-body MR examination.
Methods
and Materials: 26 consecutive patients (age 44 ±16 years old)
affected by Hodgkin Disease (HD, 15 cases) and non-Hodgkin lymphoma (9
DLBCL and 2 MCL) underwent whole body MR, for a total of 30 studies. Seven
no-hematologic patients were used as normal controls. ADC was extrapolated
from diffusion-weighted data set on pel vis by whole-body SE-EPI inversion
recovery imaging (b-value 800 sec/mm2), using a ROI-based method. All the
hematologic patients underwent BMB (mean interval 86 days).
Results
ADC was lower in controls than in patients with lymphoma
(p < 0.0001) and it increased significantly with bone marrow cellularity with no
linear fit (p=0.002). Furthermore, ADC was significantly lower in low cellular
marrow (cellularity < 30%, p < 0.05).
Conclusion
ADC seems to be a potential biomarker of bone marrow
cellularity in patients affected by lymphoma. A prospective study on a largest
population could be useful to confirm this preliminary data and to evaluate
clinical implications of these findings.
B-0580 11:51
Optimisation of b-values in MR diffusion-weighted acquisitions through
information theory: a mathematical justification for consensus
A. Alberich-Bayarri, R. Sanz-Requena, G. García-Martí, L. Marti-Bonmati;
Valencia/ES (
[email protected])
Purpose: To address the problem of b-value optimisation in DW-MR as a
signal compression problem in the frame of information theory and the
properties of the Fisher information matrix (FIM), focusing on 4 optimum b-
values that contain most of the informati on of the signal and provide minimum
estimation error of the diffusion parameters.
Methods
and Materials: In order to analyse the amount of information of the
biexponential signal decay model, the FIM was calculated, which objectivises
the amount of information that an observation carries about unknown
S260
BA C D E F G
Saturday
parameters. To determine the typical biol ogical distributions of D, D* and f
values through different organs and parenchyma, a systematic literature review
of relevant intra-voxel incoherent motion (IVIM) DW studies in brain, breast,
abdomen, pelvis and musculoskeletal tissues was performed. The
determination of the 4 optimum b-values that achieved a proper fit of the IVIM
model was performed by considering the b-value 0 in conjunction with the 3 b-
value ranges providing the maximums of the 3 FIM diagonal elements.
Results
The optimum b-values obtained for brain were 0, 15, 65 and
682s/mm2; for breast 0, 8, 41 and 390s/mm2; for abdomen 0, 10, 50, 351
s/mm2; for pelvis 0, 25, 110, 674s/mm2; musculoskeletal 0, 24, 110,
657s/mm2.
Conclusion
An optimum set of b-values according to information theory was
obtained for different regions and biologic al situations in the body. The results
together with a validation currently being performed with clinical data will add
relevant insight into consensus over a standardised b-value sampling scheme
in DW-MR.
10:30 - 12:00 Room F2
Breast
SS 902
MRI
Moderators:
U. Bick; Berlin/DE
J. Veltman; Almelo/NL
B-0581 10:30
Influence of background enhancement on the diagnostic accuracy of
breast MRI
M. Dietzel
1, W.A. Kaiser2, P.A.T. Baltzer3; 1Erlangen/DE, Jena/DE, 2Jena/DE,
3Vienna/AT, Jena/AT (
[email protected])
Purpose: Background enhancement (BE) in breast MRI is often attributed to
hormonal stimulation. Although strong BE is considered as a diagnostic
challenge in clinical practice, empirical evidence for this assumption is limited.
The present study aims to investigate the diagnostic accuracy of breast MRI
stratified by the degree of background enhancement.
Methods
and Materials: Consecutive patients undergoing breast MRI (1.5 T,
unenhanced T2w and dynamic contrast-enhanced T1w sequences in
concordance with international recommendations) with subsequent histological
sampling of imaging detected lesions were eligible for this IRB approved
retrospective study. Breast MRI were read by two experienced radiologists
blinded to histopathology results in consensus. Lesions were classified
according to BI-RADS. Furthermore, background enhancement (BE) was
investigated and graded on an ordinal scale as "distinct" or "not distinct".
Finally, diagnostic parameters were calc ulated and stratified by the grade of
BE.
Results
664 lesions were included (423 malignant, 241 benign). BE was
"distinct" in 78 (11.7%) and "not distinct" in 586 cases (88.3%). Sensitivity and
specificity of breast MRI showed only slight differences between the "not
distinct" (93.0% and 81.7%) and "distinct" BE group (94.9% and 74.4%; all:
P=n.s). However, the PPV (positive predictive value) was significantly lower in
the subgroup exhibiting "distinct" BE (78.7%) compared to the "distinct" BE
subgroup (90.6%; P=0.02).
Conclusion
Presence of "distinct background enhancement" leads to an
increased false positive rate, significantly decreasing the PPV of breast MRI.
B-0582 10:39
Comparison of morphologic and dynamic characteristics of only MR-
visible lesions at 1.5 T vs. 3 T according to 425 MR-guided breast
biopsies
A. Malich
1, J. Dvorak1, U. Teichgräber2, A. Kott1, J. Feger1; 1Nordhausen/DE,
2Jena/DE (
[email protected])
Purpose: To compare morphological features of only MR-visible lesions at
1.5 T vs. 3 T according to the histopathology after MR-guided biopsy.
Methods
and Materials: 425 MR-guided biopsies were analysed. Lesions
homogeneity, margins, oedema, T2w-density, adjacent vessels, shape, etc.
were analysed and matched to histopathology. 354/71 interventions were
performed at 1.5 T/3 T (Philips Achieva/Ingenia). Mean lesion size was 6 and
7 mm.
Results
285/354 and 62/71 biopsies were finished successfully (19.5% vs.
9.8%). Most of 1.5 T interventions were aborted due to claustrophobia, lack of
space, the only reason for abortion at 3 T was lack of lesions visualisability.
50.8%/42.2% were proven as B2 at 1.5 T/3 T; 14.4%/24.0% as in situ and
15.3%/24.0% as malignancies. Oedema was observed more common at 3 T:
benign:13.3%; in situ: 29.4%; malignant: 11.8% at 3 T (10.6%;17.6%;13.0% at
1.5 T). Spiculations were significantly more often visible at 3 T at all dignities
(40.0%; 23.5%; 47.2% at benign, in situ, malignant lesions) vs. 21.7%; 25.5%;
57.4% at 1.5 T. Adjacent vessels were observed in 17.2%; 11.8%; 27.8% at
1.5 T vs. 20.0%; 23.5%; 29.4% at 3 T-based MR-guided biopsies. Ring
enhancement was more common at 3 T (20.0%; 23.5%; 29.4% at 3 T vs.
17.2%; 11.8%; 27.8% at 1.5 T). Unsharp edge was more common at
malignancies at 1.5; related spicul ations were more obvious at 3 T
(malignancies; unsharp edge 57.4% vs. 29.4%; spiculations 18.5% vs. 52.9%).
Conclusion
Morphologic characteristics differ dignity-related (malignancies
are spiculated, inhomogeneous, unsharp with ring enhancement, adjacent
vessel and blooming) but also according to higher resolution of 3 T-MRI.
Lesion discrimination is more reliable at 3 T with a higher percentage of
(pre)malignant histologies according to MR-guided biopsy. Biopsy procedure at
3 T is more comfortable due to larger bore and better positioning opportunities.
B-0583 10:48
Time-to-peak tumor sub-volume in invasive carcinomas and
fibroadenomas
M. Nadrljanski, R. Maksimovic, V. Plesinac-Karapandzic, M. Nikitovic,
B. Markovic-Vasiljkovic, Z. Milosevic; Belgrade/RS
(
[email protected])
Purpose: To assess the distribution of time-to-peak (TTP) intralesional signals
and define the TTP tumor sub-volume (TTP Vol). in benign and malignant
breast lesions, as it is known that fibroadenomas (FA) have lower blood vessel
density than invasive ductal carcinomas (IDC).
Methods
and Materials: Forty patients were assessed with 1.5 T unit on DCE-
MRI examination with Gd-DTPA. Tumor volume (Tu Vol). was computed for
each lesion, taking into consideration the three dimensions. TTP Vol. was
computed for each lesion in the largest connected area of pixels at a set
threshold. The lesions were histologically verified as FA (n=20) or IDC (n=20)
and statistically analysed. TTP Vol./Tu Vol. ratio, as the relation between the
'hot-spot' and the whole tumor, was calculated for all lesions.
Results
The difference in Tu Vol. between the two subgroups (7.0 ±4.3 for IDC
vs. 6.2 ±5.1 for FA, p=0.36), was not significant, unlike the difference in TTP
Vol. in two subgroups (5.3 ±3.1 for IDC vs. 3.4 ±3.2 for FA, p=0.02). The
difference in the TTP Vol./Tu Vol. ratio between the two subgroups (0.77 ±0.11
for IDC vs. 0.52 ±0.14 for FA, p < 0.0001) was highly statistically significant.
Highly significant correlation between the 'hot-spot' volume and the whole
tumor volume was confirmed for IDC (r=0.92).
Conclusion
TTP Vol. was greater in IDC compared to FA, particularly if
regarded as the 'hot-spot volume' to tumor volume ratio, pointing to the
correlated vascular and tumor growth observed in IDC.
B-0584 10:57
Breast MRI in the evaluation of nipple discharge: less is more
R. Ramiro Gandía, J. Camps Herrero, A. Cervera Araez, J. Cano Gimeno,
V. Ricart Selma, M. Forment Navarro, C. Martinez Rubio; Alzira/ES
(
[email protected])
Purpose: To analyse whether breast MRI in patients with pathologic nipple
discharge adds any valuable information.
Methods
and Materials: Retrospective analysis in 123 consecutive patients
with a diagnosis of pathologic nipple discharge and breast MRI exams. US,
mammography, cytology and galactography were performed in 93, 76, 74 and
6.5% of all patients respectively. BMRI included a T2 FSE sequence and a 3D
dynamic T1 GRE sequence (spatial resolution 0.7/0.7/2 mm). MRI was
considered negative when no enhancement, ductal or glandular enhancement
and probably benign lesions were seen. MRI was deemed positive when
segmental, irregular or nodular enhancement adjacent to the central ducts.
Influence of MRI was rated as: non existent, diagnosis of a lesion, change of
therapeutic approach, overdiagnosis and false negative lesions. Gold standard
was pathology. No pathology with a follow-up of greater than 24 months or a
benign lesion were considered negative. A diagnosis of papilloma or a
malignant lesion was considered positive.
Results
MRI had no influence in 18.6%, influenced therapy in 20.3%,
diagnosed a lesion in 14.6%, showed a greater extent in 5.7%, FP in 9.7%, FN
in 0.8% and non conclusive in 2 patients. Mean follow-up was 27.2 months.
Diagnostic accuracy in showed a sensitivity, specificity, PPV and NPV of
94.7%, 76%, 64.3% and 97% respectively.
Conclusion
MRI is very useful diagnostic tool for diagnosis in 20% and for
exclusion of disease and therefore can potentially avoid further diagnostic and
surgical procedures in patients with a negative study due to its almost 100%
NPV.
Author Disclosures:
J. Camps-Herrero: Advisory Board; Bayer. Research/Grant Support; Bayer.
Speaker; Bayer.
S261
BA C D E F G
Saturday
B-0585 11:06
Breast MRI in Pptients with unilateral hematic nipple discharge:
comparison with galactography
S. Gigli, F. Di Pastena, L. Ballesio, S. Tardioli, I. D' Ambrosio, L. Porfiri;
Rome/IT (
[email protected])
Purpose: to assess the role of breast MRI in evaluating Patients with unilateral
hematic or sero-hematic nipple discharge in comparison with galactography.
Methods
and Materials: in this retrospective study we included 53 patients
with unilateral hematic/serohematic secretion who performed both
galactography and MRI. We evaluated the capability of both the techniques to
identify the presence/absence of ductal pathology and to distinguish benign
from malignant lesions.Lesions classified as BIRADS 1/2 underwent to
follow-up (performed with mammography, ultrasound or cytology)while the gold
standard to assess the type of pathology in lesions classified as BIRADS 3.4
and 5 was the histological examination after surgery.
Results
after surgery and follow-up,8 patients had no pathology (15%),23 had
a diagnosis of papilloma (43%),11 of papillomatosis (21%),5 of Ductal Cancer
In Situ (10%)and 6 of papillary carcinoma (11%).Concerning the ability to
identify the presence/absence of pathology, both galactography and MRI
presented a specificity of 100% while sensitivity was 98% for MRI vs 49% of
galactography.The ROC analysis was used to test the diagnostic ability of both
the modalities separately considered (Galactography and MRI) compared with
histological analysis. Considering MRI we found a statistically association
between mass intraductal enhancement and the presence of papilloma
(p < 0.001;AUC: 0.957; CI 0.888 -1.025),between papillomatosis and ductal
enhancement (p < 0.001;AUC: 0.790; CI 0.623-0.958),between segmental
enhancement and DCIS (p=0.007 AUC: 0.750; CI 0.429 -1.071,) and between
papillary cancer and linear enhancement (p=0.011).
Conclusion
MRI can be considered a valid and alternative tool in detecting
ductal pathologies showing higher values of sensitivity and specificity in
comparison with galactography.
B-0586 11:15
MRI screening for silicone breast implant rupture: accuracy, inter- and
intraobserver variability using explantation results as reference standard
M.C. Maijers, F.B. Niessen, E.F.H. Veldhuizen, M.J.P.F. Ritt, R.A. Manoliu;
Amsterdam/NL (
[email protected])
Purpose: In Europe the recall of PIP silicone breast implants in 2010 was
followed by recommendation to remove all ruptured implants. Consequently,
large numbers of asymptomatic women underwent MRI. The accuracy and
interobserver variability of MRI is relevant when indications for surgery are
chiefly based on MRI. Accuracy of MRI was not previously studied in a cohort
of women, all of whom underwent explantation regardless of symptoms.
Methods
and Materials: A prospective cohort study included 107 women with
214 PIP silicone implants who underwent explantation preceded by MRI of the
breasts. Two radiologists independently reevaluated in 2013 all MRI
examinations being blinded for the previous diagnoses or the outcome at
surgery. A structured protocol was developed to describe the MRI findings. The
ex vivo findings served as reference standard.
Results
In 208 of the 214 explanted prostheses, radiologists agreed
independently about the condition of the implants. In five of the six cases they
disagreed upon (2.6%), they subsequently reached a non-imposed consensus.
158 implants were correctly diagnosed as intact and 40 as ruptured. A
sensitivity of 93%, a specificity of 93%, a positive predictive value of 77% and a
negative predictive value of 98% was found. The interobserver agreement was
excellent with a Kappa value of 0.92.
Conclusion
MRI has a high accuracy in diagnosing rupture in silicone breast
implants. Considering the high Kappa value of interobserver agreement, MRI
appears to be a consistent diagnostic test. A simple, uniform reporting protocol,
may improve communication between radiologist and plastic surgeon.
B-0587 11:24
Prepectoral oedema as a morphological sign in MR mammography
C. Kaiser1, M. Herold2, J. Krammer1, M. Dietzel2, P.A.T. Baltzer2, W.A. Kaiser2,
S.O. Schönberg1, K. Wasser1; 1Mannheim/DE,
2Jena/DE (
[email protected])
Purpose: To retrospectively evaluate the role of prepectoral oedema (PE) as a
morphological sign in the differential diagnosis of breast lesions.
Methods
and Materials: Between 01/2005 and 10/2006, a total of 1109
consecutive MRM exams have been performed in our institution. In this study,
only patients who would later be biopsied or operated in our own hospital were
included. They had no previous operation, biopsy, intervention, chemotherapy,
hormone replacement therapy or previous mastitis. In total, 162 patients with
180 histologically correlated lesions were included. The evaluations were
performed by four experienced radiologists in consensus.
Results
180 evaluated lesions included 104 malignant lesions (93 invasive
and 11 non-invasive cancers) and 76 benign lesions. PE was detected in 2.6 %
of benign lesions (2/76), in none of the DCIS-cases (0/11) and in 25.8 % of
malignant lesions (24/93) (p < 0.000). PE were found significantly more
frequently in presence of malignant tumours above 2 cm in diameter [(47.1 %;
16/34) vs. (13.8 %; 8/58)] (p < 0.001). PE was not statistically associated to
malignant tumour-type, presence or absence of additional DCIS, and number
of lesions. This resulted in the following diagnostic parameters for PE as an
indicator for malignancy: sensitivity of 19.3%, specificity of 97.3%, PPV of
92.3%; NPV of 48%; accuracy 57.7%.
Conclusion
In case of occurrence, the "Prepectoral Edema Sign" seems to
be a specific indicator for malignant tumours with a high-positive predictive
value, independent from its entity.
B-0588 11:33
Axillary node staging in patients with breast cancer on preoperative 3 T
breast MRI: a pilot study
B. Bresson, T. Dao, P. Beaussart, F. Pigneur, E. Meyblum, R. Bosc,
Y. Belkacemi, A. Rahmouni, A. Luciani; Creteil/FR (
[email protected])
Purpose: To assess the accuracy of 3 T magnetic resonance imaging (3 T
MRI) in detecting metastatic axillary lymph nodes on routine preoperative
breast MRI examination.
Methods
and Materials: 72 patients with histologically proven breast cancers
referred for breast MRI staging between July 2010 and June 2013 were
retrospectively studied. MRI examinations were performed at 3 T, using a
dedicated breast coil covering also bilateral axillary area. MRI protocol included
T1, T2 and 3D sequences after dynamic injection of gadolinium, with a 0.8 mm
isotropic voxel. The detectability of axillary nodes, and the presence of specific
MR criteria including size, signal and morphological criteria were assessed and
confronted to pathological post-operative findings.
Results
A total of 21 full axillary lymph node dissections, 45 sentinel lymph
node dissections and 6 image-guided biopsy were available for pathological
confrontations. 14 patients showed metastatic axillary nodes. Using combined
size and morphological criteria, the detectability of axillary nodes on 3 T MRI
was 79% with sensitivity, 98% specificity, and 92% NPV. Overall 11/14 N+
patients were correctly identified on MRI.
Conclusion
Metastatic axillary lymph nodes can be suggested on routine
preoperative 3 T breast MRI examinations with high specificity and NPV, with
figures close to those reported using dedicated axillary surface coils.
B-0589 11:42
Preoperative breast MRI: should BI-RADS 3 category be considered?
M. Páramo, R. Zalazar, L.J. Pina Insausti, F. Martinez Regueira, A. Elizalde,
B. Olartecoechea, N. Rodriguez-Spiteri; Pamplona/ES (
[email protected])
Purpose: To compare the sensitivity (SE) and specifity (SP) of preoperative
breast MRI including BI-RADS 3 category lesions as positive for malignancy or
not.
Methods
and Materials: 51 consecutive patients with histologically proven
breast cancer and preoperative breast MRI were selected. 134 breast lesions
were evaluated. Preoperative MRI images were interpreted retrospectively by
two breast radiologists blinded to the final diagnosis. BI-RADS 3 lesions were
included as malignant in group 1 and as benign lesions in group 2. All the
lesions were compared with the gold standard (histology or follow-up). The
Results
were collected using an excel table to calculate the sensitivity and
specificity, and the statistical significance was studied using the PEPI software.
Results
Out of 134 breast lesions, 77 were histologically malignant and 57
were benign. In group 1 the SE and SP of preoperative MRI were respectively:
SE (98.7 %) and SP (5.3 %). In group 2 the SE and SP of preoperative MRI
were respectively: SE (92.2%) and SP (91.2%). The comparison between both
groups showed statistically significance for SP (5.3% vs 91.2%, p 0.05). Only 5
BI-RADS 3 lesions were finally malignant, all of them were separated from the
main tumour less than 15 mm.
Conclusion
Considering BI-RADS-3 category as benign in preoperative MRI
increases significantly the specificity without decreasing the sensitivity. All of
the malignant BI-RADS 3 lesions were close to the main tumour ( < 15 mm).
B-0590 11:51
Breast MRI as a problem-solving tool: systematic review and meta-
analysis
B. Bennani-Baiti, P.A.T. Baltzer; Vienna/AT
Purpose: To assess the validity of breast MRI as a problem-solving tool.
Methods
and Materials: Two investigators independently performed a
systematic review using predefined search terms. Discrepancies were resolved
by final consensus cross-evaluation. We selected only studies whereby breast
MRI was used for problem-solving purposes i.e. inconclusive
mammographic/sonographic findings. Studies that focused solely on assessing
mammographic microcalcification malignancies were excluded. Standard of
Reference
had to be established either by histopathology or follow-up
S262
BA C D E F G
Saturday
examinations. Study design, technical parameters, number of true positives,
false positives, false negatives and tr ue negatives were extracted from the
original publications, and possible bias was determined using the QUADAS 2
applet. Statistical analysis included data pooling, forest plot construction, and
heterogeneity testing.
Results
11 studies met our inclusion criteria. These comprised 1062 lesions,
including 777 benign and 285 malignant le sions. The negative predictive alue
(NPV) ranged from 87.5 to 100%, with a pooled NPV of 99.1%. A fixed effects
model was applied due to low heterogeneity (P=0.129). The positive predictive
value (PPV) was highly heterogeneous (P < 0.0001) ranging from 25 to 96.4%.
Based on a random effects model, the pooled PPV was 53.2%.
Conclusion
This is the first meta-analytical study to demonstrate that breast
MRI can reliably exclude malignancy when applied as a problem solving tool.
These Results: i. alleviate the controversy surrounding the use of breast MRI
as a problem solving tool; ii. strongly supports its implementation as a problem-
solving tool and; iii. should impact the guidelines in breast imaging.
10:30 - 12:00 Room I/K
Neuro
SS 911
Neurodegenerative diseases
Moderators:
S. Haller; Geneva/CH
T.A. Yousry; London/UK
B-0591 10:30
The pattern of white matter alteration in patients with Parkinson's disease
according to cognitive status
S.-K. Lee, N. Shin; Seoul/KR (
[email protected])
Purpose: To assess the pattern of white matter alteration in patients with
Parkinson's disease (PD) according to cognitive status by using diffusion
tensor imaging.
Methods
and Materials: From August 2011 till September 2012, we enrolled
patients with PD-intact cognition (PD-IC, n=10), PD-mild cognitive impairment
(PD-MCI, n=15), PD with dementia (PDD, n=11), and healthy control subjects
(n=15). Fractional anisotrophy (FA) map of patient groups was compared with
each other and that of control subjects by using tract-based spatial
statistics (TBSS) where age and education were included as covariates in
analysis of covariance.
Results
Compared with control subjects, FA values were significantly
decreased in many major tracts in patients with PD-MCI and more PDD as
follows: corpus callosum, bilateral su perior longitudinal fasiculi, bilateral
anterior corona radiata, bilateral anterior limbs of internal capsule, bilateral
external capsule, bilateral posterior thalamic radiation, bilateral cingulum, and
left inferior longitudinal fasciculus. Compared with patients with PD-IC, there
were significantly decreased FA values in the body of corpus callosum in
patients with PDD. There were not significantly decreased FA values in
patients with PD-IC compared with control subjects. PDD patients with shorter
disease duration before dementia ( < 5 years) showed greater decrease in FA
values than those with longer disease duration ( 5 years).
Conclusion
These data suggest that white matter damage in PD exhibits a
greater extent with increasing levels of cognitive impairment. In addition, white
matter alteration responsible for PDD may differ according to disease duration
of PD.
B-0592 10:39
Iron load in genetic Parkinson's disease measured using MRI
N. Pyatigorskaya, J.-C. Corvol, M. Sharman, A. Brice, S. Lehericy; Paris/FR
(
[email protected])
Purpose: Although most cases of Parkinson's disease (PD) are sporadic,
genetic forms of PD exist. In idiopathic PD (IPD), iron load is increased in the
substantia nigra (SN). The goal of this work is to measure the iron load in the
SN and the basal ganglia (BG) of patients carrying genetic mutations
associated with PD.
Methods
and Materials: Measurements of T2 and T2* relaxation times were
performed at 3 Tesla in 20 IPD patients, 20 subjects with LRRK2 or Parkin
mutations related to PD (10 symptomatic patients and 10 non-symptomatic
carriers), and 20 control subjects. In all cases, R2* and R2 mean values for SN
and BG were calculated.
Results
R2* values were increased in IPD and mutation-carrying PD patients
as compared to controls (p < 0.0001) and also in mutation-carrying PD patients
as compared to IPD (p=0.0023). Asymptomatic mutation carriers showed R2*
values higher than those of controls (p= 0.021), but not significantly different
from those of IPD patients. No changes were observed for R2 values in SN
and BG or R2* values in BG.
Conclusion
Iron load in the SN of the mutation-carrying subjects
(symptomatic and asymptomatic carriers) was increased. Genetic PD patients
showed greater iron load increases than IPD patients. Iron load, analysed with
R2* can be regarded as a biomarker of the nigrostriatal degenerative changes
in mutation carriers associated with neurodegeneration. The role of iron load in
neurodegeneration in mutation-carrying subjects, as well as its prognostic
value has yet to be elucidated.
B-0593 10:48
Is there an association between leukoaraiosis volume and diabetes?
L. Saba, R. Montisci, R. Sanfilippo, M. Piga, E.A. Genovese; Cagliari/IT
(
[email protected])
Purpose: The association between diabetes mellitus and leukoaraiosis is still
debated while the association with hypertension, age and carotid artery
stenosis is widely demonstrated. In this work our purpose is to evaluate the
association of white matter hyperintense lesion volume and diabetes in a
cohort of patients who underwent an MRI of the brain at our institution.
Methods
and Materials: Fifty-four consecutive patients (mean age 72 ± 9
years, males 42) were prospectively recruited at our Institution before
undergoing carotid endarterectomy. The patients were assessed for the
presence of vascular risk factors, including diabetes mellitus, hypertension,
hyperlipidemia. The patients underwent an admission MRI of the brain which
included T2-FLAIR, T2-SE and DWI sequences. FLAIR-leukoaraiosis lesion
volume was performed by a neuroradiologist, blinded to the presence of risk
factors, using a semi-automated segmentation technique. ROC analysis was
performed to evaluate the AUC of FLAIR-leukoaraiosis lesion volume and
number of lesions with respect to the vascular risk factors.
Results
The ROC curve analysis showed an AUC of 0.725 (SE = 0.082 and
95% CI from 0.593 to 0.873) with a statistically significant p value of 0.002
between the presence of diabetes mellitus and the FLAIR-leukoaraiosis lesion
volume. In the ROC curve analysis between the presence of diabetes mellitus
and number of lesion the AUC was 0.715 (SE = 0.085 and 95% CI from 0.553
to 0.845) with a p value of 0.0119.
Conclusion
Our data demonstrate an association between diabetes mellitus
and the volume of the cerebral white matter abnormality.
B-0594 10:57
3 Tesla brain MRI including quantitative diffusion tensor imaging to
differentiate between Parkinson's disease and atypical parkinsonism
F.J.A. Meijer, A. Tuladhar, B. Bloem, B. Goraj; Nijmegen/NL
(
[email protected])
Purpose: To evaluate 3 Tesla brain MRI in differentiating between Parkinson's
disease (PD) and atypical parkinsonism (AP) in patients presenting with
parkinsonism but uncertain initial clinical diagnosis. The added value of
quantitative diffusion tensor MRI (DTI) was evaluated.
Methods
and Materials: Prospective observational cohort study in 60 patients.
At baseline brain MRI including DTI was performed followed by mean clinical
follow-up of 18 months during which probable diagnoses could be made in 44
patients (26 PD, 18 AP). Brain MRI abnormalities were scored. DTI data were
analysed by the region of interest (ROI) method and the discriminative power
of each ROI was evaluated by multivariate logistic regression. The area-under-
the-receiving-operating-curve (AUC) was used to evaluate the discriminative
power of routine brain MRI and routine brain MRI combined with DTI ROI mean
diffusivity (MD) and fractional anisotropy (FA) values.
Results
AUC of routine brain MRI in differentiating PD and AP was 0.75 (95%
CI 0.60-0.91, sensitivity 89% and specificity 54%) when at least one
abnormality was present; in case of at least two abnormalities AUC was 0.81
(95% CI 0.67-0.95, sensitivity 78% an d specificity 81%). When combined with
MD values in the putamen or MD and FA values in the midbrain, the AUC
could be increased to 0.83 (95% CI 0.71-0.96)- 0.89 (95% CI 0.79-0.98).
Conclusion
In the work-up of parkinsonism with uncertain diagnosis, 3 Tesla
brain MRI can aid in differentiating between PD and AP which could be
improved by quantitative DTI-MRI, but the discriminative power depends on
defining imaging criteria.
Author Disclosures:
B. Bloem: Board Member; Editorial Board member of Movement Disorders
(earlier), Associate Editor for the Journal of Parkinson's disease (currently),
Physiotherapy Canada (currently). Consultant; Boehringer Ingelheim, Danone,
Glaxo-Smith-Kline, Solvay. Grant Recipient; Alkemade Keuls fund, Michael J
Fox Foundation, Netherlands Organisation of Scientific Research, Prinses
Beatrix Foundation, Stichting Internationaal Parkinson Fonds.
S263
BA C D E F G
Saturday
B-0595 11:06
Diffusion tensor imaging at 3-T MR for detection of patients with
depression and comorbid hypertension in depression
Y. Liu, H. Yuan, X. Zeng, Z. Wang, H. Zhang; Beijing/CN (
[email protected])
Purpose: Diffusion tensor imaging (DTI) was used to investigate the
differences of white matter impairment between depression and comorbid
hypertension in depression. To evaluate the correlation between fractional
anisotropy (FA) and degrees of depression.
Methods
and Materials: Patients with depression (n=15) and comorbid
hypertension in depression (n=27) were compared with age- and sex-matched
healthy control subjects (HC, n=26). Voxel-based analysis was used to analyse
DTI data (SPM8, DTI studio). FA and mean diffusivity (MD) in patients with
depression and comorbid hypertension in depression were compared with HC
respectively. The correlation between FA and scores of Hamilton Depression
Scale (HAMD
17) was evaluated.
Results
1.Compared to HC, FA decreased significantly in patients with
depression (P uncorrected 50) in the right inferior
frontal gyrus, right precuneus, right lingual gyrus, left superior temporal gyrus
and left cerebellum posterior lobes. 2. More cerebral regions of patients with
comorbid hypertension in depression were involved (P uncorrected < 0.001,
F=3.18),including bilateral superior temporal gyrus, bilateral superior frontal
gyrus, bilateral thalamus, bilateral caudate, right parahippocampal gyrus, left
middle temporal gyrus, left cerebellum posterior lobes. 3. There were no
significant differences in MD. 4. FA in left (r=-0.458) and right superior frontal
gyrus (r=-0.474) and right superior temporal gyrus (r=-0.474) were negatively
correlated with scores of HAMD17 (P=0.001).
Conclusion
Our results reveal underlying extensive white matter impairments
in patients with depression. The different patterns of decrease in FA suggest
hypertension may play a synergistic action in the progress of depression. FA
can reflect degrees of depression and is more sensitive than MD.
B-0596 11:15
Diffusion Kurtosis imaging at 3-T MR imaging for detection of individuals
with depression and comorbid hypertension in depression
X. Zeng, H. Yuan, Y. Liu, Z. Wang, H. Zhang; Beijing/CN
(
[email protected])
Purpose: Diffusion Kurtosis Imaging (DKI) was used to investigate the
differences of white matter impairment between depression and comorbid
hypertension in depression.
Methods
and Materials: We used a voxel-based analysis method to analyse
DKI data (SPM8, http://www.fil.ion.ucl.ac.uk/spm/software/spm8; DKE,
http://academicdepartments.musc.edu/cbi/dki/DKE) in patients with depression
(n=15; 3 males, 12 females) and comorbid hypertension in depression (n=27; 5
males, 22 females) compared with age- and sex-matched no cognitive
impairment cases (NCI, n=26; 8 males, 18 females).
Results
Compared to NCI, we found significant decrease in Mean Kurtosis
(MK) of patients with depression (P
uncorrected 50)
in the right inferior frontal gyrus, bilateral inferior and middle temporal gyrus,
bilateral precuneus, midbrain and bilateral cerebellum posterior lobes;
Compared to NCI, there are more cerebral regions of individuals with comorbid
hypertension in depression involved according to the significant decrease in
MK (P
corrected 50), including right inferior
frontal gyrus, bilateral superior frontal, bilateral inferior and middle temporal
gyrus, bilateral thalami, bilateral limbic lobe uncus, bilateral parahippocampa
gyrus, bilateral precuneus, bilateral posterior cingutate and bilateral cerebellum
posterior lobes.
Conclusion
Our results revealed underlying extensive white matter
impairments in patient with depression. The different patterns of decrease in
MK betweendepression and comorbid hypertension in depression suggest
hypertension might play a synergistic action in the progress of depression. As
a potential biomarker, DKI could differentiate the patients from the healthy.
B-0597 11:24
Validation of an MRI rating scale for amyloid related imaging
abnormalities
A. Bechten
1, M.P. Wattjes1, D. Purcell2, E. Sanchez1, M. Daams1, H.M. Arrighi2,
F. Barkhof1; 1Amsterdam/NL, 2San Francisco, CA/US (
[email protected])
Purpose: MRI abnormalities in relation to amyloid-2 (A 2) lowering
immunotherapy with edema or effusion (ARIA-E) describes 3 different
manifestations, represented as parenchymal hyperintensity, sulcal
hyperintensity and gyral swelling. The aim of our study is to validate the use of
a recently introduced MRI rating scale for ARIA-E in a larger patient group and
multiple raters.
Methods
and Materials: We evaluated a group of 75 patients, 30 with known
ARIA-E and 45 without and we test the Inter-rater reliability between 5
neuroradiologists using intraclass correlation coefficient. All patients included in
this study were part of phase II multicenter, randomised, double blind, placebo-
controlled multi ascending dose immunisation study by using Bapineuzumab.
Results
Raters successfully applied the scale with a high agreement in the
identification of ARIA-E cases. We observed a high inter-rater agreement for
scores of sulcal hyperintensity (ICC= 0.917; 95% CI, 0.86-0.96) and for the
combined scores of the 2 ARIA-E findings, parenchymal and sulcal
hyperintensity (ICC = 0.881; 95% CI, 0.80 - 0.93). A slightly lower agreement
for parenchymal hyperintensity (ICC =0.681; 95% CI, 0.51-0.84) was observed.
Conclusion
There was a very high consensus between the raters to identify
the ARIA-E cases and for the scoring for the different ARIA-E findings. This
rating scale is a very simple and effecti ve tool to evaluate the severity of this
adverse event in patients recruited for A 2 lowering therapeutic trials. It allows
accurate monitoring of this adverse event and could aid in dose adjustment.
Author Disclosures:
D. Purcell: Consultant; Consulting Fee or Honorarium Janssen. H.M. Arrighi:
Employee; Janssen Alzheimer Immunotherapy Research & Development LLC.
F. Barkhof: Consultant; Consulting Fee or Honorarium Janssen.
B-0598 11:33
The prevalence of cortical superficial siderosis in a memory clinic
population
H.I. Zonneveld, J.D.C. Goos, M.P. Wattjes, N.D. Prins, P. Scheltens,
W.M. van der Flier, J.P.A. Kuijer, M. Muller, F. Barkhof; Amsterdam/NL
(
[email protected])
Purpose: Cortical superficial siderosis (SS) is a recently recognised
manifestation of cerebral amyloid angiopathy (CAA). The aim of this study was
to determine prevalence, topography and severity of SS in a memory clinic
patient cohort and its possible association with Alzheimer's disease (AD).
Methods
and Materials: We included 809 patients (56%men, age 66 ±10
years) from the Amsterdam Dementia Cohort between November 2010 and
November 2012 scanned on a 3 Tesla MRI system. We analysed prevalence
and topography of cortical SS according to demographic, clinical, and MRI
data. Agreement for SS detection between two neuroradiologists was
calculated by using Cohen's Kappa.
Results
Agreement for detection of SS was excellent (unweighted 5 of 0.81).
In 17 patients (2.1%) cortical SS was found without a known cause. The
prevalence of idiopathic SS differed according to diagnostic groups (p < 0.001):
nearly 5% in AD patients (n=168) versus 2% of mild cognitive impairment
patients (n=143), and 2.5% of other types of dementia (n=80). By contrast, SS
was not found in patients with subjective complaints (n=168) or those with
other disorders (n=157). The presence of SS was associated with age,
cognition, APOE J4, microbleeds and white matter hyperintensities (all
p < 0.05).
Conclusion
The prevalence of cortical SS in a memory clinic setting is higher
than reported in the general population, but lower than reported in CAA. The
relatively high prevalence of SS in AD and its clinical associations suggest that
SS is a relevant radiological manifestation of amyloid pathology in AD. Further
longitudinal research is needed to investigate clinical relevance.
Author Disclosures:
M.P. Wattjes: Consultant; Biogen-Idec. Other; lectures for: Biogen Idec, Bayer
Healthcare, Roche and Janssen Cilag. N.D. Prins: Advisory Board; Boehringer
Ingelheim and Envivo. Grant Recipient; Vereniging AEGON. Research/Grant
Support; rain Foundation of the Netherlands and Alzheimer Nederland.
Speaker; Janssen and Novartis. P. Scheltens: Research/Grant Support; GE
Healthcare, Danone Research and MERCK (for the istitution). Speaker; Lilly,
GE Healthcare, Lundbeck, Danone and Jansen AI-Pfizer (paid to institution). F.
Barkhof: Consultant; Bayer-Schering Pharma, Sanofi-Aventis, Biogen-Idec,
TEVA, Merck-Serono, Novartis, Roche, Synthon BV, Jansen Research.
Research/Grant Support; Dutch MS Society and EU-FP7.
B-0599 11:42
Diffusion tensor imaging of the hippocampus and posterior cingulate
fasciculus in mild cognitive impairment and early Alzheimer's disease:
our initial results
D. Grasso, C. Borreggine, D. Melchionda, E. Carapelle, L. Macarini,
L.M. Specchio; Foggia/IT (
[email protected])
Purpose: The aim of this study was to show the role of Diffusion Tensor
Imaging (DTI) as a potential tool in evaluating microstructural white matter
alterations in patients with Mild Cognitive Impairment (MCI) and early
Alzheimer's disease (AD).
Methods
and Materials: Fifty five subjects (15 MCI; 20 AD; 20 controls) were
enrolled. All patients were assessed using physical, neurological and
neuropsycological tests. Conventional MRI sequences and DTI were acquired.
Fractional anisotropy (FA) and Apparent Diffusion Coefficient (ADC) values
were measured using the region of interest (ROIs) method in the bilateral
hippocampal body, parahippocampal white matter and posterior cingulate.
Data were analysed using Statistical Package For Social Sciences software
(ver 21.0; SPSS Inc, Chicago, IL, USA).
S264
BA C D E F G
Saturday
Results
In MCI and AD patients we observed a significant FA decrease and
ADC increase in the hippocampus, posterior cingulate and parahippocampal
white matter compared to controls. Cognitive tests findings showed high
correlation with DTI parameters, especially FA values in the hippocampus body
and parahippocampal white matter.
Conclusion
Microstructural alterations in the hippocampus, parahippocampal
white matter and posterior cingulate were detected by DTI technique in MCI
and AD patients. DTI parameters in the hippocampus and parahippocampal
white matter could be a potential tool to define microstructural damages in
early AD patients and seem to be more correlated with cognitive skills than DTI
changes in the posterior cingulate.
B-0600 11:51
Gender and age aspects of hippocampal anatomy in MDD patients
compared to healthy volunteers using methods of MR morphometry
T. Rostovtseva, R. Ezhova, N. Ananieva; St. Petersburg/RU
(
[email protected])
Purpose: Investigation of the hippocampal formation structural variants in
patients with major depression disorder (MDD) compared to healthy
volunteers.
Methods
and Materials: 139 patients in the age from 18 to 50 were examined.
The first group of patients consisted of 101 healthy volunteer. The second
group included 28 patients with MDD. All of the patients underwent MRI of the
brain on 1.5T Toshiba scanner using standard brain protocol with addition of
3D MPRAGE sequence and following voxel morphometry ((FreeSurfer/
Massacyusetts General Hospital - URL.; http://surfer.nmr.harvard.edu).
Results
Different structural variants of hippocampus were found either in
healthy volunteers or in patients with MDD. We haven't found significant age
correlation of the hippocampal volume of healthy volunteers in the age before
50 years. Hippocampal volume was certainly bigger in men than in women.
Early manifestation of MDD and high severity of the disease according to
Montgomery-Asberg depression rating scale were found more often in patients
with hippocampal structural variants compared to patients with normal
architecture of hippocampus.
Conclusion
Morphological variants of the m ediobasal parts of temporal lobes
couldn't be, as we consider, the direct eti ological factor of major depression
disorder, but their presence could possibly be the sign of development failure
of the brain, and in particular of the brain structures involved in formation of the
emotions.
10:30 - 12:00 Room L/M
Cardiac
SS 903
Coronary plaques and aorta
Moderators:
A.J.B.S. Madureira; Porto/PT
P. Stolzmann; Zurich/CH
B-0601 10:30
State-of-the-art CT scanners from four different vendors do not
substantially affect coronary artery calcium risk classification in a large
cohort
M.J. Willemink
1, R. Vliegenthart2, T. Leiner1, R.P.J. Budde1, R.L.A.W. Bleys1,
M. Das3, M. Prokop4, N. Buls5, P.A. de Jong1; 1Utrecht/NL, 2Groningen/NL,
3Maastricht/NL, 4Nijmegen/NL, 5Brussels/BE (
[email protected])
Purpose: Coronary artery calcification (CAC) scores assessed with CT have
emerged as an important imaging biomarker for cardiovascular risk
classification. American Heart Association guidelines recommend CAC-scoring
in asymptomatic adults with low-to-intermediate and intermediate
cardiovascular risk, concerning approximately 40% of the United States adult
population. Treatment strategies depend on CAC-scores, but state-of-the-art
CT-systems from the major vendors have never been compared head-to-head.
Our purpose was to determine the inter-vendor variability of CAC-scores ex
vivo with state-of-the-art CT-scanners and to assess the effects of this
variability on risk-category reclassification in a large population-based cohort.
Methods
and Materials: We evaluated the differences in CAC-scores
between CT-scanners from four different vendors. Fifteen ex vivo human
hearts were placed in a phantom resembling an average human adult. Hearts
were scanned at equal radiation dose settings for each vendor. CAC-scores
were quantified with clinically used semi-automatic software. The ex vivo CAC-
scores were used to simulate the effects of different CT-scanners on
reclassification of 432 ol der individuals from a population-based study at
intermediate cardiovascular risk based on Framingham risk scores.
Results
CAC-scores differed substantially between CT-scanners with median
CAC-scores ranging from 332 (quartiles 114-1135) to 469 (quartiles 183-1381)
between vendors (P < 0.05). Simulation showed that these differences resulted
in cardiovascular risk-clas sification shifts in 0.5 to 6.5% of individuals at
intermediate risk by using a CT-scanner from a different vendor.
Conclusion
Among individuals at intermediate cardiovascular risk, state-of-
the-art CT-scanners produce substantially different CAC-scores, which can
Result
in reclassification to high or low risk in up to 6.5% depending on the
vendor.
B-0602 10:39
Phase-contrast computed tomography: coronary plaque characterisation
by quantitative phase-contrast Hounsfield units
H. Hetterich
1, M. Willner2, C. Habbel1, J. Herzen2, T. Saam1, F. Pfeiffer2,
M.F. Reiser1, F. Bamberg1; 1Munich/DE,
2Garching/DE (
[email protected])
Purpose: Poor contrast in low-absorbing materials limits accurate
atherosclerotic plaque characterisation by absorption-contrast computed
tomography (ACT). Phase-contrast CT (PCT) is an experimental technique
relying on X-ray phase-shift, yielding a hi gher contrast in biological soft tissue.
Phase-contrast Hounsfield units (HU-P) can be calculated using the refraction
index. We hypothesised that plaque components including fibrous (Fib), lipid-
rich (Lip) and calcified tissue (Cal) can be differentiated based on HU-P.
Methods
and Materials: Fifteen human coronary arteries were imaged at a
laboratory-based set-up using a conventional X-ray tube (35 kV) and grating-
interferometer. Tomographic images were reconstructed with a resolution of
100 m and correlated with histopathology. In both ACT- and PCT-data,
regions corresponding to Fib, Lip or Cal based on histopathology were
manually traced. Mean HU-A, HU-P and signal-to-noise ratios (SNR) were
calculated for analysed regions.
Results
A total number of 316 cross-sections with 184 Fib, 56 Lip and 119
Cal containing regions were assessed. Fib, Lip and Cal were associated with
significant different mean HU-P (61.7± 18.5, 39.9 ±16.1 and 447.3 ±155.5;
p=0.00013) and HU-A (76.4 ±30.6, 41.5 ±97.5 and 4305.2 ±1276.6; p=0.0017).
However, we observed a substantial overlap in HU-A between Fib and Lip,
while there was little overlap in HU-P. The receiver operating characteristic
curve showed a significant higher area under the curve for HU-P (0.92) than
HU-A (0.85). PCT was associated with an improved SNR in both Fib and Lip
(p=0.0024).
Conclusion
PCT can reliably differentiate important components of
atherosclerotic lesions based on quanti tative HU-P, indicating its high potential
for improved assessment of coronary artery disease.
B-0603 10:48
Interobserver agreement of the quantitative computed tomography
assessment of high-risk coronary plaque features in the ROMICAT II trial
P. Maurovich-Horvat1, S. Puchner2, M. Lu2, T. Liu2, T. Mayrhofer2,
U. Hoffmann2, M. Ferencik2; 1Budapest/HU, 2Boston, MA/US
(
[email protected])
Purpose: Excellent reproducibility for CCTA plaque measurements is a
prerequisite for quantitative plaque assessment in clinical practice and
research trials. We explored interobserver variability of plaque measurements
in the ROMICAT II trial.
Methods
and Materials: Two readers independently evaluated 30 randomly
selected CCTA exams from 473 patients enrolled in the ROMICAT II study.
Each reader performed a qualitative assessment for the presence of calcified,
non-calcified plaque and the napkin-ring sign (plaque with low CT attenuation
surrounded by rim like higher CT attenuation). All plaques were assessed
quantitatively using dedicated software (QAngio CT, MEDIS, Leiden, The
Netherlands). For each plaque proximal, distal normal reference, minimal
luminal area, remodelling index, plaque volume, % plaque burden, low
attenuation plaque volume ( < 30 HU), and non-calcified plaque volume
(< 130 HU) was determined. Kappa statistics was calculated to assess
interobserver agreement for binary variables and Pearson's linear correlation
coefficient continuous variables.
Results
Interobserver agreement was excellent for all measures. Kappa
values were 1.00 for the presence of the napkin-ring sign, 0.73 for the
presence of positive remodelling, 0.83 for the presence of low HU plaque, and
0.84 for the presence of plaque burden > 70%. We observed excellent
correlation for plaque burden (R=0.94, mean difference 0 ±6%), minimal luminal
area (R=0.98, mean difference 0.1 ±0.8 mm2), total plaque volume
(1.1±5.7 mm3), non-calcified plaque volume (0.7 ±5.4 mm3), and low HU
plaque volume (0.2±1.9 mm3).
Conclusion
Advanced quantitative CCTA assessment of coronary
atherosclerotic plaque including high-risk plaque features can be performed
highly reproducible in a multicenter multivendor setting of the ROMICAT II trial.
S265
BA C D E F G
Saturday
Author Disclosures:
P. Maurovich-Horvat: Grant Recipient; "Nemzeti Kivalosagi Program" TAMOP
4.2.4.A/1-11-1-2012- 0001. U. Hoffmann: Grant Recipient; National Heart,
Lung, and Blood Institute (U01HL092040 and U01HL092022) and the National
Institutes of Health (UL1RR025758, K23HL098370).
B-0604 10:57
Can we evaluate the effect of genetic and environmental influences on
coronary anatomy and plaque characteristics? initial experience with
coronary CT angiography in twin pairs
P. Maurovich-Horvat
1, A.L. Jermendy1, T. Horváth1, E. Nagy1, Á.D. Tárnoki1,
D.L. Tárnoki1, P. Kitslaar2, B. Merkely1, G. Jermendy1; 1Budapest/HU,
2Leiden/NL (
[email protected])
Purpose: Twin studies provide a unique method for assessing the phenotypic
impacts of environmental and genetic factors through the comparison of
monozygotic (MZ) and dizygotic (DZ) twins. The heritability of coronary
anatomy, which may influence plaque formation through local haemodynamic
effects, and the heritability of plaque morphology were not yet studied. We
sought to assess these parameters. Here, we report our initial experience.
Methods
and Materials: In this classical twin study we plan to enroll 100
asymptomatic, adult twin pairs with no history of coronary artery disease. The
%plaque burden, plaque volume and non-calcified plaque volume were
assessed by coronary CT angiography (Philips 256-slice iCT, Best, The
Netherlands). Plaque analysis was perfomed with a dedicated software
(QAngio CT Research Edition, Medis B.V., Leiden, The Netherlands).
Results
At this point, 30 twins (mean age 57 ±9 years, 22% male), 6 MZ and 9
DZ pairs, were enrolled. Dyslipidemia was present in 57%, hypertension in
27%, diabetes in 10% of the twins and 33% of the twins were smokers.
Coronary atherosclerosis was present in 12 subjects and 56 plaques were
detected. We observed a median total plaque burden of 40.3 (IQR:34.7-
45.9)%; plaque volume of 39.6 (IQR:24.9-82.9) mm3 and a non-calcified
plaque volume of 15.4 (IQR:8.6-30.2) mm3.
Conclusion
Our first impression is that CCTA of twins provides a valuable
tool to assess heritability of coronary geometry and coronary plaque
morphology. To perform statistically robust analysis, the enrollment of 100 twin
pairs is warranted. The target completion date of the study is March 2014.
Author Disclosures:
P. Maurovich-Horvat: Research/Grant Support; "Nemzeti Kivalosagi Program"
TAMOP 4.2.4.A/1-11-1-2012- 0001
B-0605 11:06
Computed tomography characteristics of coronary artery atherosclerosis
in subjects with lower extremity peripheral artery disease and no cardiac
symptoms
T. Miszalski-Jamka
1, S. Licholai2, B. Laskowicz2, M. Konieczynska2,
M. Trystula2, L. Slowik2, M. Urbanczyk2, M. Pasowicz2, P. Jazwiec1;
1 Wroclaw/PL, 2Krakow/PL
Purpose: Computed tomography coronary angiography (CTCA) enables non-
invasive evaluation of coronary artery atherosclerosis. However, its value to
assess coronary artery disease (CAD) in subjects with lower extremity
peripheral artery disease (PAD) and no cardiac symptoms is unknown. The
Objectives
are to determine the value of CTCA to assess coronary artery
atherosclerosis and to evaluate the relationship between coronary artery
plaque characteristics and severity of peripheral atherosclerosis in subjects
with lower extremity PAD and no cardiac symptoms.
Methods
and Materials: Sixty-five individuals (45 males, 20 females, mean
age 62.5 ±7.6 years) with lower extremity PAD and no cardiac symptoms
underwent CTCA.
Results
CTCA revealed CAD in 56 subjects. Twenty-two had obstructive
CAD. The mean ankle-brachial index (ABI) was 0.64 ±0.16. Twenty-six
individuals demonstrated abnormal carotid artery intima-media thickness (IMT).
ABI<median, if compared to ABI median was associated with higher proportion
of obstructive multivessel to single vessel CAD (8:4 versus 1:9;p=0.01) and
higher number of coronary artery segments with mixed plaques (2.3 ±2.2
versus 1.2 ±1.3;p=0.02). Comparing patients with abnormal and normal IMT,
the former demonstrated higher proportion of obstructive multivessel to single
vessel CAD (7:3 versus 2:10;p=0.01) and higher number of coronary artery
segments with non-calcified (1.9 ±3.2 versus 0.6 ±1.4;p=0.04) and mixed
plaques (2.3±2.1 versus 1.3±1.7;p=0.049).
Conclusion
CTCA may be effective to detect CAD in subjects with lower
extremity PAD and no cardiac symptoms. The low ABI and abnormal IMT are
associated with more extensive CAD and higher burden of high-risk coronary
artery plaques.
B-0606 11:15
Iterative reconstruction algorithms in coronary CT angiography for the
characterisation of coronary atherosclerotic plaque: a comparison with
histology
S. Puchner
1, M. Ferencik1, P. Maurovich-Horvat1, M. Nakano2, F. Otsuka2,
H.-U. Kauczor3, R. Virmani2, U. Hoffmann1, C. Schlett1; 1Boston, MA/US,
2Gaitherburg, MD/US, 3Heidelberg/DE (
[email protected])
Purpose: To evaluate whether iterative reconstruction algorithms improve the
accuracy of coronary CT angiography (CCTA) for coronary plaque
characterisation compared to histology.
Methods
and Materials: CCTA and histological data were acquired from the
coronary arteries of 3 ex-vivo hearts. CT images were reconstructed by using
filtered-back projection (FBPR) as well as adaptive-statistical (ASIR) and
model-based (MBIR) iterative reconstruction algorithms. Cross-sectional
images were co-registered between CCTA and histology and a semi-
automated plaque assessment was performed for each reconstruction
algorithm. The results were then compared to histology.
Results
Of 173 included cross-sections, presence of a lipid-core plaque (LCP)
was in 26 cross-sections based on histology. Plaque area < 60 HU was larger
in cross-sections with LCP as compared to non-LCP (mean plaque area
< 60 HU in FBPR 5.17vs.3.16,p < 0.0001;in ASIR 5.58vs.3.16,p < 0.0001;in
MBIR6.49 vs.3.23,p < 0.0001, respectively). This translated into an area under
the curve (AUC) for detecting LCP by CTA of 0.803 for FBPR, 0.850 for ASIR,
0.903 for MBIR. The AUC of MBIR was significant higher as for FBPR
(p=0.01). In cross-sections with any calcification by histology, the plaque area
> 180 HU in CCTA increased with increasing size of calcification in histology.
As compared to FBPR and ASIR, a reduced plaque area > 180 HU was
observed for MBIR (p=0.03 and 0.008,respectively).
Conclusion
Plaque area < 60 HU in CCTA was associated with LCP
regardless of the reconstruction algorithm. However, MBIR demosntrated a
higher accuracy for LCP and degreased potential blooming of calcification
compared to ASIR and FBPR. This may improve the value of CCTA for patient
risk stratification.
B-0607 11:24
Distensibility of the ascending and descending aorta in patients with
aortic stenosis
L. Myska, C. Chin, L. Henderson, S. Semple, D. Newby, M. Dweck,
S. Mirsadraee; Edinburgh/UK (
[email protected])
Purpose: Patients with bicuspid valve disease and aortic stenosis commonly
develop aortic dilatation that may relate to an associated aortopathy or
mechanical stress. We sought to demonstrate whether these patients had
altered aortic distensibility compared to those with a trileaflet valve and
subjects without stenosis.
Methods
and Materials: We recruited 95 subjects (age 63 ±9 years) with
different aortic valve morphologies (23 bicuspid (BAV), 50 tricuspid (TAV) and
21 non-stenotic). Distensibility on both ascending and descending aorta was
measured on MRI as the change in cross-sectional aortic area per unit change
in blood pressure.
Results
Significant difference in distensibility is demonstrated between
ascending and descending aorta in both the stenotic groups (P 0.05). Moreover, patients with BAV have
higher mean distensibility compared to patients with TAV although it was not
statistically different. The mean distensibility (mmHg -1) in the stenotic bicuspid
group of the ascending aorta was 3.39± 1.9 x10 -3 and of the descending
5.71±2.9 x10-3. For the stenotic tricuspid group values were 2.6 ±1.2 x10-3 in the
ascending and 4.16 ±2.3 x10-3 in the descending. The distensibility in controls
were 6.19±6.3 and 6.32±3.47, respectively. No association was found between
the severity of aortic stenosis and distensibility.
Conclusion
The study shows that there is a significant impact on the
distensibility ratio, of ascending to descending aorta, in patients suffering from
aortic stenosis.
B-0608 11:33
Evaluation of aortic valve calcium and feasibility of transcatheter aortic
valve implantation with first- and second-generation transcatheter heart
valves
M. Avanesov, M. Seiffert, L. Conradi, C. Lunau, J. Schirmer, G. Adam,
S. Blankenberg, H. Reichenspurner, G. Lund;
Hamburg/DE (
[email protected])
Purpose: With the recent availability of several second-generation
transcatheter aortic valve implantation (TAVI) devices, a correlation between
aortic valve calcium load and paravalvular regurgitation remains to be
investigated. We performed a retrospective CT based assessment of aortic
valve calcium in correlation with hemodynamic performance of different
transcatheter heart valves.
S266
BA C D E F G
Saturday
Methods
and Materials: In 156 patients preoperative contrast-enhanced CT
scans with prospective ECG gating were available for retrospective analysis.
Three-dimensional reconstruction of CT data was performed using the
3Mensio software (3Mensio Medical Imaging, Bilthoven). After calibration for
contrast agent density, calcium load was quantified within the device-landing
zone. Data were correlated with echocardiographic measurements.
Results
Total aortic valve calcium was 2468 ±1685 mm3 with eccentric
distribution ( > 50% of calcium load at one cusp) in 26.3% and calcium
protruding into the left ventricular outflow tract in 41.7% of patients. Devices
implanted were the Edwards Sapien XT (n=52), Medtronic CoreValve (n=33),
Symetis Acurate (n=25), JenaValve (n=20), and Medtronic Engager (n=26)
valves. Postprocedural paravalvular regurgitation was none or trace in 65.2%
and mild in 34.8%. Although a trend towards a correlation of calcium load and
paravalvular regurgitation was observed (p=0.054), no differences in
hemodynamic performance with regard to different valve types and aortic valve
calcium could be demonstrated.
Conclusion
TAVI using first- and second-generation devices can be
performed with good hemodynamic results, irrespective of annular calcification.
Aortic valve calcium seemed to be associated with increased paravalvular
regurgitation, however no relevant predictors of regurgitation for the different
transcatheter heart valve prostheses could be identified.
B-0609 11:42
Transcatheter aortic valve implantation (TAVI) for severe aortic stenosis:
the significance of non-vascular incidental pathology at CT angiography
and the impact on outcome
J.C.L. Rodrigues, P. Murphy, M. Hamilton, N.E. Manghat; Bristol/UK
(
[email protected])
Purpose: Untreated severe aortic stenosis (AS) has poor prognosis and is
common amongst older patients with comorbidity who are at high risk for
definitive aortic valve replacement. TAVI is a less invasive alternative but
approximately 33% may have iliofemoral atherosclerosis precluding TAVI. The
burden of incidental non-vascular pathol ogy (INVP) in pre-TAVI patients has
not been quantified before.
Methods
and Materials: We reviewed 100 consecutive pre-TAVI CT
angiography (CTA) scans. All CTAs were reported by Consultant
Cardiovascular Radiologists. The radiological reports were reviewed for the
documentation of INVP which were stratified by clinical relevance. The
presence of INVP in those managed conservatively was compared to those
who underwent TAVI.
Results
INVP was documented in 88%, consisting of unsuspected possible
malignancy in 8%, progression of known malignancy in 1%, conditions
requiring acute treatment in 17% (e.g. pulmonary oedema) and indeterminate
findings present in 19% (e.g. lung nodules). However, no INVP was anticipated
to have worse prognosis than severe AS. Of the 100 pre-TAVI patients who
underwent CTA, 40% proceeded to TAVI. A trend towards more incidental
findings requiring acute treatment was seen in conservatively managed
patients (30% vs 60.5%, P = 0.15). Emphysema was present in significantly
more conservatively managed patients compared to TAVI patients (18.4% vs
0%, P < 0.05).
Conclusion
INVP in patients undergoing CTA prior to TAVI are common and
potentially clinically relevant. Less than 50% referred for CT (aorta) pre-TAVI
actually underwent TAVI. The presence of emphysema on pre-TAVI CTA may
be a potential predictor of subsequent conservative management.
B-0610 11:51
CT-angiography of the aortic annulus for prosthesis sizing in TAVI:
comparison of predictive values of major anatomic parameters
F. Schwarz, D. Zinsser, P. Lange, M. Greif, M.F. Reiser, C. Kupatt,
C.R. Becker; Munich/DE (
[email protected])
Purpose: To compare the predictive value of CT-derived annulus
measurements prior to transcatheter aortic valve implantation (TAVI) for the
selection of prosthesis size for two major valve models.
Methods
and Materials: In 351 TAVI-patients (235: CoreValve, 116 Edwards
Sapien), optimal prosthesis size was determined during the TAVI procedure by
inflation of a balloon catheter at the aortic annulus. All patients had previously
undergone CTA of the bodytrunk at our institution. Two readers independently
determined long and short axis as well as circumference and area of the aortic
annulus. A nested cross-validation approach was used to estimate the
predictive power of these parameters for the prosthesis size ultimately
implanted and to define optimal cut-off values.
Results
There was excellent agreement between observers for the major
anatomic parameters (ICC's > 0.85). Differences between patients who
underwent implantation of the small, medium or large prosthesis were
significant for all evaluated param eters and both valve models (p's < 0.05).
Annulus area and circumference had equally high predictive power for
prosthesis size (multi-class AUC's: 0.86, 0.87, 0.87, 0.88). Application of the
optimal cut-off values for annulus circumference suggested by our cross-
validation strategy (CV:7.7;8.9 cm; ES:7.2;8.8 cm) would have resulted in the
selection of the size ultimately considered optimal in 87%(306/351) of cases.
Conclusion
CT-based annulus measurements permit good prediction of the
prosthesis size considered optimal during TAVI. Applying the calculated cutoff
values, identical prosthesis size would been selected in 87% of cases on the
basis of CT alone. Extending our model to the degree of calcification might
further increase its predictive power.
10:30 - 12:00 Conf. Room M3
Interventional Radiology
SS 909
Aortic and neuro interventions
Moderators:
R.F. Dondelinger; Liege/BE
D. Filippiadis; Athens/GR
B-0611 10:30
Endovascular aneurysm repair (EVAR): is imaging surveillance robust
and does it influence long-term mortality?
M. Waduud
1, M. Ritchie1, R. Yadavali2, S. Lim2, R. Bhat3, W. Choong3,
S. Ingram4, L. Cormack4, J. Moss1; 1Glasgow/UK, 2Aberdeen/UK, 3Dundee/UK,
4Edinburgh/UK
Purpose: EVAR is the dominant treatment strategy for abdominal aortic
aneurysms. However, due to uncertainty regarding long-term durability an on-
going imaging surveillance programme is required. The aim was to assess the
deliverability and its effect on all-cause and aneurysm-related mortality.
Methods
and Materials: A retrospective analysis of all EVAR procedures
carried out in the four main Scottish Vascular Units. Patients were identified
locally and imaging data collected by manually searching a combination of
different databases. Complete imaging follow-up was defined as following the
local protocol for each site and subsequent continuing annual imaging.
Outcome measures included all-cause and aneurysm-related mortality. Cause
of death was obtained from the death certificate.
Results
Data were available for 569 patients from 2001 to 2012. All centres
had data for a minimum of 5 contiguous years. Follow-up period ranged from
1.66 to 4.55 years (median 3.03). Overall 53% had complete imaging
surveillance, 43% partial and 7% none. For the whole cohort all-cause 5-year
mortality was 33.5% and aneurysm-related mortality was 4.5%. All-cause
mortality in patients with complete, partial and no imaging was 49.9%,19.1%
and 47.2% and aneurysm-related mortality was 3.7%, 4.4% and 9.5%,
respectively. All-cause mortality was significant higher in patients with complete
imaging surveillance (p < 0.001). No significant differences were observed in
aneurysm related mortality (p=0.2).
Conclusion
Only half of EVAR patients achieve complete long-term imaging
surveillance over a minimum 5-year period. However, incomplete imaging
could not be linked to any increase in mortality. This information may have
implications for the national screening programme.
B-0612 10:39
CTA with fluoroscopy image fusion guidance in endovascular complex
aortic aneurysm repair
A.M.H. Sailer, M.W. de Haan, A.G. Peppelenbosch, M.J.H.M. Jacobs,
J.E. Wildberger, G.-W.H. Schurink; Maastricht/NL (
[email protected])
Purpose: To evaluate the application and benefit of intraoperative guidance by
means of live fluoroscopy image fusion with computed tomography
angiography (CTA) in endovascular thoraco-abdominal aortic repair.
Methods
and Materials: CTA with fluoroscopy image fusion road-mapping
was prospectively evaluated in pat ients with thoraco-abdominal aortic
aneurysms who underwent fenestrated and/or branched endovascular repair
(FEVAR/BEVAR). C-arm cone beam computed tomography (CBCT) was
performed prior to the interventions and manually co-registered to patients'
outpatient diagnostic CTA dataset. Radiation dose of CBCT in terms of dose
area product (DAP, in mGym
2) was registered. Total procedural iodinated
contrast material dose, overall procedure time and fluoroscopy time were
compared between the fusion group (n=31) and case controls (n=31).
Results
Radiation dose of CBCT was 1.47 ± 0.41 mGym
2 (mean±SD). Image
co-registration was feasible in all patients within approximately five minutes.
Fusion image road-mapping was used for navigation and positioning of the
devices and catheter guidance during access to target vessels. Iodinated
contrast material dose and procedure time were significantly lower in the fusion
group compared to case controls (159 cc (95% CI: 132 cc; 186 cc) versus
199 cc (95% CI: 170 cc; 229 cc), p=0.037 and 5.2 hours (95% CI: 4.5 h; 5.9 h)
versus 6.3 hours (95% CI: 5.4 h; 7.2 h), p=0.022). No significant differences in
fluoroscopy time were observed.
S267
BA C D E F G
Saturday
Conclusion
Image fusion guidance is a valuable addition in complex
endovascular interventions. The technology supports accurate target vessel
canalisation and stentgraft placement. It contributes to reduce iodinated
contrast material dose and procedure time.
B-0613 10:48
A 10-year retrospective review of pelvic ischaemic complications due to
internal iliac artery embolisation prior to EVAR
J.G. McGarry, A.O. Alenezi, F.P. McGrath, M.F. Given, A.N. Keeling, M.J. Lee;
Ireland/IE (
[email protected])
Purpose: Internal iliac artery (IIA) embolisation is frequently performed prior to
endovascular aortic aneurysm repair (EVAR) when concomitant common illiac
aneurysms necessitate graft extension into the external iliac arteries (to
prevent endoleaks via retrograde IIA flow). Because the safety of this
procedure remains questionable, we aimed to determine the incidence of
associated pelvic ischaemic complications, and to establish what parameters
are predictive of increased patient risk.
Methods
and Materials: A retrospective review of clinical records and pre-
procedural CT angiography was conducted for all patients undergoing IIA
embolisation prior to EVAR from 2002 to 2012. Bivariate analysis (Spearman
correlation tests: p < 0.05 significant) was used to test for differences between
two groups, those with or without new-onset pelvic ischaemic complications
during follow-up.
Results
Twenty-five patients underwent elective IIA embolisation average 23
days prior to EVAR (average age 72.2; 22/25 male). 3/25 patients underwent
bilateral embolisation, 22 unilateral. Overall, 7/25 patients (28%) experienced
new-onset pelvic ischaemic complications, including erectile dysfunction (1/25),
bilateral leg paraesthesia (1/25), and buttock claudication (BC) (5/25). Long-
term persistence of BC could be confirmed definitively in only 2 of the 5
patients. A shorter time interval from embolisation to EVAR correlated
statistically with increased risk of pelvic ischaemic complications (p < 0.03).
Bilateral IIA embolisation was independently associated with BC (p < 0.032).
No patient risk factors or CT angiographic factors were predictive of increased
risk.
Conclusion
We conclude that by avoiding both a short-time interval from
embolisation to EVAR, and bilateral IIA embolisation, the risk of persistent
ischaemic complications due to IIA embolisation can be significantly minimised.
B-0614 10:57
Outcomes of endovascular treatment for aortic pseudoaneurysm in
Behcet's disease
S. Kim, D. Lee, M. Kim, J. Won; Seoul/KR (
[email protected])
Purpose: To evaluate the effectiveness of endovascular stent-grafting for
surgical management of aortic pseudoaneurysm in patients with Behcet's
disease (BD).
Methods
and Materials: We present a single-institution retrospective cohort of
patients with aortic pseudoaneurysm and BD treated with aortic stent-grafting.
CT imaging was obtained preoperatively in all patients and once within two
weeks postoperatively, and then annually. Clinical follow-up and erythrocyte
sedimentation rate (ESR) were used to follow BD activity. Immunosuppressant
therapy was instituted prior to endovascular treatment unless a
contraindication existed.
Results
From 1998 to 2012, 10 patients (eight male, two female; median age
39) with BD and aortic pseudoaneurysm were treated with endovascular stent-
grafting at this institution. 90% of these patients received immunosuppressive
therapy before and after surgical treatment. The median follow-up period was
57 months (interquartile range, IQR 43-72). The locations of the 12
pseudoaneurysms treated in this cohort were infrarenal abdominal aorta
(seven), descending thoracic aorta (four), and aortic arch (one). Median
pseudoaneurysm size was 4.5 cm (IQR 3.4-5.9). At long-term follow-up,
complete resolution of the aortic pseudoaneurysm was noted in all patients. No
endoleaks occurred. Newly developed pseudoaneurysm at the distal margin of
the stent-graft was noted in one patient 17 months after the stent-graft
procedure. One patient required a subsequent stent-graft placement for an
expanding pseudoaneurysm of the subclavian artery. No patient deaths
occurred during the follow-up period.
Conclusion
Endovascular treatment of aortic pseudoaneurysm with stent-
grafting in patients with BD is safe and effective with long-term durability.
B-0615 11:06
Accurate fluoroscopy-guided fenestration of aortic dissections using a
conventional reentry catheter: first clinical experiences
F. Wolfschmidt, I. Platzer, J. Goltz, W. Kenn, R. Leyh, T. Bley, R. Kickuth;
Würzburg/DE (
[email protected])
Purpose: Evaluation of the feasibility and effectiveness of fluoroscopy-guided
needle insertion for gaining controlled target lumen reentry in fenestration of
aortic dissections.
Methods
and Materials: Between 2009 and 2013, eleven consecutive
patients (10 male patients, mean age 51 ± 14 years) with malperfusion
syndrome from aortic dissection (8 type B and 3 type A dissections) were
treated using the Outback LTD reentry catheter (Cordis, Miami Lakes, Florida).
This 6-F catheter is equipped with a curved, extendable coaxial needle that
allows accurate real-time fluoroscopy-guided puncture of the target lumen.
After successful reentry a 0.014" guidewire may be directed through the
coaxial needle into the target lumen. Patients had developed renal (n=6),
mesenterial (n=1), spinal (n=3) and iliofemoral (n=7) ischemia. Three patients
underwent stentgraft implantation prior to fenestration. Technical success, total
procedure time, clinical outcome, follow-up imaging (CTA and MRA including
flow measurements) and complications were evaluated.
Results
The technical success rate using this reentry catheter was 100%.
Total procedure time was 72 ± 30 minutes; range 32 - 139 minutes. 3 patients
with iliofemoral malperfusion syndrome required additional stent implantation.
In all patients a significant improvement of clinical symptoms occurred.
Follow-up imaging (mean follow-up period 164 days) showed a stable
dissection membrane. One patient with spi nal malperfusion died due to his bad
general condition during hospitalisation.
Conclusion
This conventional fluoroscopic-based reentry catheter is a
reliable and safe tool for gaining controlled target lumen reentry in fenestration
of aortic dissections with malperfusion syndrome.
B-0616 11:15
Uncovered stent implantation in complicated acute aortic dissection type
B
A. Massmann, T. Kunihara, P. Fries, G.K. Schneider, H.-J. Schäfers,
A. Buecker; Homburg a.d. Saar/DE (
[email protected])
Purpose: To retrospectively evaluate the technical feasibility and mid-term
Results
of uncovered thoraco-abdominal bare metal stent placement in
complicated acute aortic dissection Stanford type B (AADB).
Methods
and Materials: Fourteen patients (3 female, range 44-71 years) with
AADB suffering from apparent gastrointestinal malperfusion and claudication
underwent uncovered metal stent implantation (diameter 7-28 mm, length 40-
100 mm) into the thoraco-abdominal aorta (n=23) and visceral arteries (n=5).
Results
Stenting yielded considerable clinical improvement in 13 of 14
patients. More than one stent (up to four) was placed in seven patients (2
celiac, 1 mesenteric, 2 renal, 8 aorto-iliac). Follow-up CTA revealed collapse of
four aortic stents (diameter 9-25 mm, length 100 mm) after one week.
Catheterisation and balloon dilatation of all four stents were possible, but re-
collapse occurred 1 month later in all cases. However, patients were
asymptomatic; ultrasound and CTA show ed sufficient perfusion of the visceral
arteries in all patients. Follow-up ranged from 6 months to 5 years (average 2.5
years). One patient required an iliaco-mesenteric bypass for treatment of
chronic mesenteric ischaemia, one month after stent placement. No other
patient required additional interventional or surgical therapy.
Conclusion
Thoraco-abdominal stent placement is a technically feasible
minimally invasive therapy in complicat ed AADB yielding similar clinical results
compared to treatment by dedicated covered aortic stentgraft. Stent size
should be below the normal aortic diamete r to avoid possible stent collapse.
B-0617 11:24
Feasibility of the superselective test with propofol for determining
eloquent brain regions in the endovascular treatment of arteriovenous
malformations
J.A. Jordan, J.C. Llibre; La Habana/CU (
[email protected])
Purpose: The superselective test for determining eloquent brain areas, carried
out prior to the embolisation treatment for AVMs, is a tool contributing to
increase the safety of endovascular procedures. Taking into account
amobarbital unavailability, it was decided to carry out the present study, aimed
at demonstrating propofol's efficacy and safety as an alternative to the use of
amobarbital to perform this test.
Methods
and Materials: A group of 58 patients that went through 91
embolisation sessions were treated for brain AVMs using endovascular surgery
between February 2006 and February 2011. The superselective test was
performed prior to embolisation with Histoacryl, using the intra-arterial
administration of 20 mg of propofol through a microcatheter positioned near the
AVM nidus.
Results
10 (7.8%) of the 128 superselective tests turned out positive.
Neurological deficits appeared immediately after propofol administration, lasted
for a minute and disappeared after 5 minutes. Only one of the patients showing
a negative test result developed neurologi cal deficits after embolisation, for
99.2% NPV. Despite their positive test results, six patients were embolised and
five developed postembolisation neurological deficits, for 83.3% PPV. The test
showed 83.3% sensitivity and 99.2% specificity.
Conclusion
The use of propofol to perform the superselective test during
brain AVM embolisation is a safe and effective alternative to the use of
amobarbital, and may predict the occurrence of post - embolisation ischemic
complications.
S268
BA C D E F G
Saturday
B-0618 11:33
Mechanical thrombectomies performed in acute ischaemic stroke
patients in Paula Stradins Clinical University hospital during 2010. - 2013
A. Balodis, K. Kupcs, H. Kidikas, E. Miglane; Riga/LV
(
[email protected])
Purpose: Evaluate safety and efficacy of endovascular thrombectomy as a
treatment method of acute ischaemic stroke during large artery occlusion.
Methods
and Materials: This was a retrospective study of 96 patients with
acute ischemic stroke hospitalised in Paula Stradins Clinical University hospital
from 28.12.2010 till 01.08.2013 and treated by endovascular thrombectomies
due to large artery occlusions. Telephone interviews were performed 3 months
after thrombectomy using modified Rankin Scale (mRS). Paired samples T-test
was used.
Results
There were 50 (52.1%) males and 46 (47.9%) females, mean age
was 67.13±10.22 (SD) years.The majority of thrombs were localised in anterior
circulation area - 77 (80.20%), in posterior circulation area - 19 (19.8%). Mean
time from stroke's onset to mechanical thrombectomy was 252.28 ±97.71 (SD)
min in anterior circulation area and 417.90 ±170.59 (SD) in posterior circulation
area.Mean National Institutes of Health Stroke Scale (NIHSS) until
thrombectomy was 16.58 ±6.51 (SD), mean NIHSS after was 8.91± 7.80 (SD).
The difference was statistically significant, p < 0.0001.MRS before
thrombectomy - mRS 3 got 1 (1.0%) patient with mild disability, mRS 4-5 got
95 (99.0%) patients with moderately severe and severe disability. At 3 months
after, 37 (38.5%) patients had good outcome mRS-2 and less, 19 (19.8%)
patients had mild disability, 9 (9.4%) patients had severe disability, mRS 4-5.
There are no data about 9 (9.4%) patients. Total mortality after 3 months was
22 (22.9%)-mRS 6.
Conclusion
Mechanical thrombectomy can signi ficantly improve neurological
outcomes in patients with severe ischaemic stroke. Accurate patients' selection
improved the late neurological results compared to our previous study.
B-0619 11:42
Transcatheter embolisation of extracranial aneurysms using n-butyl
cyanoacrylate
J. Koizumi, C. Itou, N. Mori, T. Sekiguchi, T. Hashimoto, K. Myojin, T. Ichikawa,
Y. Imai; Isehara/JP (
[email protected])
Purpose: To clarify the efficacy of transcatheter embolisation using n-butyl
cyanoacrylate (NBCA) for extracranial aneurysms.
Methods
and Materials: For 18aneurysms (5splenic, 5internal iliac, 3hepatic
arteries, 1celiac, 1 gastroduodenal, 1renal, 1uterine artery, 1 thoracic aorta) in
17 patients, embolisation using NBCA with Lipiodol (33-67%) was performed.
The etiology includes atherosclerosis (10), pseudoaneurysm (3), myocosis (3),
and median arcuate ligament compression (2). In 13aneurysms, coils were
used as frames or nests for subsequent glue injection. Flow control using a
balloon catheter was applied in 5aneurysms and distal neck was embolised by
coils in 5aneurysms to prevent glue migration. The coil and glue packing
densities for the aneurysmal volumes were calculated.
Results
For 8.2± 9.9 mL of aneurysm volumes, 1.9 ±2.0 mL of NBCA was
injected after framing by 0.2 ±0.2 mL of coil volumes; the coil packing density
was only 3.8 ±4.3%. In 2splenic aneurysms, glue was migrated to splenic
parenchyma intentionally as partial splenic embolisation. In other two internal
iliac artery aneurysms, minor distal migration was observed without clinical
sequels. Incomplete occlusion occurred in one aneurysm due to shortness of
glue and recurrence occurred in two mycotic aneurysms. NBCA expanded
4.4±3.9 times in the aneurysms.
Conclusion
Transcatheter embolisation using NBCA was useful in reducing
coil usage with a high success rate.
B-0620 11:51
Endovascular stenting of extra-cranial internal carotid artery or vertebral
artery occlusions in the management of acute stroke
A. Sastry, S. Nayak; Stoke-on-Trent/UK (
[email protected])
Purpose: Middle cerebral artery (MCA) embolic occlusion with concomitant
cervical internal carotid artery (ICA) occlusion is associated with a low rate of
recanalisation and poor outcome after intravenous thrombolysis. The purpose
of this study was to assess outcome of endovascular stenting of extra-cranial
internal carotid artery or vertebral artery tandem occlusions using NIHSS,
modified Rankin score (mRS) and thrombolysis in cerebral infarction (TICI)
scores.
Methods
and Materials: Retrospective analysis of our stroke thrombectomy
database identified 124 patients. In addi tion to mechanical thrombectomy, 15
patients underwent ICA stenting for tandem ICA/MCA occlusions and 3
patients had vertebral origin stenting for VA origin/basilar artery occlusions. We
examined neurological improvement defined by 10-point reduction of NIHSS
score, TICI and improved mRS = 2 & 3 score at 90 day.
Results
90-day follow-up data was available for 18 patients which showed
47%(n=7) had a reduction in the NIHSS score by greater than 10 points and a
mRS 2 at 90 days. 67%(n=10) had a good outcome with a mRS of either
2or3. 87%(n=13) achieved TICI 2b or 3 signifying successful recanalisation.
Mortality was 26 %(n=4) with 3 deaths due to malignant MCA infarction and 1
death due to pneumonia.
Conclusion
There was significant improvement in NIHSS, mRS and TICI
scores in our 18 patients who underwent endovascular stenting for extra-
cranial internal carotid artery or vertebral artery tandem occlusions. Major
Strokes due to ICA and VA origin/basilar occlusions can be successfully
treated by ICA/VA origin endovascular stenting in conjunction with mechanical
thrombectomy.
10:30 - 12:00 Board Room A
Radiographers
SS 914
Optimisation of dose and image quality in
CT
Moderators:
E. Agadakos; Athens/GR
J. Cabukovska-Radulovska; Skopje/MK
B-0621 10:30
Optimisation of paediatric head computed tomography examinations: an
experimental and clinical approach
J. Santos
1, S. Foley2, G. Paulo1, M. McEntee3, L.A. Rainford1; 1Coimbra/PT,
2Dublin/IE, 3Sydney/AU (
[email protected])
Purpose: Optimisation of paediatric head Computed Tomography (CT)
examinations.
Methods
and Materials: Preset protocols for head CT examinations, derived
from three national Portuguese paediatric centres were applied to Catphan 600
and anthropomorphic phantoms (0, 5 and 10 years old). Current exposure
parameters were manipulated to optimise radiation dose. OsiriX software
based on standard deviation pixel values was applied to measure image noise.
CT scanner dose reports provided CT Dose Index (CTDIvol-mGy) and Dose
Length Product (DLP-mGy.cm). The findings were discussed locally with the
participating centres. Based on the results a CT system upgrade with tube
current and voltage modulation proceeded in one centre. Patient data pre/post
upgrade was collated to review dose and image quality levels. Patient images
were presented in Viewdex software underwent Visual Grading Characteristic
(VGC) image quality evaluation by paediatric neuro-radiologists (n=4), using
anatomical criteria scoring.
Results
Optimisation across participating centres resulted in dose reductions
of between 13% and 65%. Post experimental optimisation similar image noise
levels to the preset were identified. The CT upgrade demonstrated a decrease
in mean dose for head CT examinations of 42%, image quality evaluation is
on-going and will be presented.
Conclusion
Minor exposure parameter manipulations facilitated paediatric CT
dose reduction with limited impact on image quality. The optimisation tests and
the system software upgrade promoted a dose reduction in children.
B-0622 10:39
Low-dose chest CT vs bedside chest x-ray in emergency patients
A. Latifi
1, M. Torkzad2, M. Beckman3, A. Sundin3, F. Labruto4; 1Manchester/UK,
2Sollentuna/SE, 3Stockholm/SE, 4Syndney/AU (
[email protected])
Purpose: In this prospective non-randomised study, the diagnostic yield of
bedside chest X-ray (bCXR) with non-contrast-enhanced low-dose chest
computerised tomography (LDCT) was compared.
Methods
and Materials: 16 subjects > 65 years planned for bCXR underwent
LDCT immediately afterwards. bCXR was performed with AP (150 KV and
2.5 mAs) and lateral (140 KV and 6 mAs) views, mean radiation dose of 0.7
mSv and LDCT (average radiation dose = 0.59 mSv). Each bCXR and LDCT
examinations were read on different occasions by three blinded radiologists
independently. The degree of general diagnostic confidence was scored (1-4).
The agreement between the results was assessed by intraclass correlation
coefficient, and Cohen's and weighted kappa.
Results
The average confidence score was always higher or the same for
LDCT compared to bCXR (mean 2.85 for reading bCXR and 3.83 for LDCT).
There was no discrepancy for diagnosis of pneumothorax on LDCT. On bCXR
however, there were two false negative and two false positive cases. Objective
measurements of atelectasis depth (ICC 0.64 vs. 0.36), depth of pleural
effusion (0.74 vs. 0.27) and heart size dimension (0.82 vs. 0.43) always
showed better agreement on LDCT readings than bCXR readings,
respectively. The following were missed on bCXR: four pulmonary opacities,
three malignancies, two patients with free intra-abdominal air and one case of
fracture. No extra finding was missed on LDCT compared to bCXR.
S269
BA C D E F G
Saturday
Conclusion
Chest LDCT with less radiation dose than bCXR discloses more
diagnoses and shows higher reliability and reader confidence.
B-0623 10:48
Psychophysical evaluation of CT image quality using human observers
and software analysis
F. Zarb1, L.A. Rainford2; 1Msida/MT, 2Dublin/IE (
[email protected])
Purpose: Comparison of objective image quality characteristics obtained from
human observer evaluations and software analysis of CT phantom images.
Methods
and Materials: A Catphan®600 CT quality assurance phantom was
scanned using protocols for four anatomical areas: posterior fossa; cerebrum;
abdomen and chest on three different CT models as part of an optimisation
strategy. CT image data sets (n=24) obtained pre and post-optimisation were
blindly evaluated by radiographers (n =8) identifying the number of distinctly
discernible line pairs and contrast discs for each of the three supra-slice sets
within the phantom's high-resolution and low-contrast modules, respectively.
The same CT data sets were also gauged using the web based service -
Image Owl for the automatic analysis of Catphan®600 images.
Results
Inter-observer reliability measured using Cronbach's ' between
human observers and again including software analysis (9
th observer) gave
'=0.97 for both instances, indicating that internal consistency of the observer
group, with and without software analysis was identical.
The results of a paired sample t-test showed no significant difference (p > 0.05)
between human observers and software analysis in 37.5% of observations for
line pairs and 37.5%; 12.5% and 50% for the three sets of contrast discs.
Conclusion
Combined use of human observers and software analysis for
evaluation of image quality in CT using phantoms is recommended. However,
the sole use of software analysis methods may provide more detail than that
obtained by human observers. Further research to measuring the clinical
relevance of such image quality findings is recommended.
B-0624 10:57
An investigation into the application of optimised CT protocols for head
examinations across clinical centres in Malta and Denmark
F. Zarb
1, S. Holm2, L.A. Rainford3; 1Msida/MT, 2Odense/DK, 3Dublin/IE
(
[email protected])
Purpose: To investigate dose and image quality differences between clinically
adopted optimised Maltese head CT protocols and preset parameters applied
in a Danish center for matched CT equipment.
Methods
and Materials: A Danish clinical center with a GE BrightSpeed Elite
16-slice CT scanner was approached to participate in the optimisation study.
Head CT protocols were reviewed from the twinned Maltese and Danish
centers. Maltese head CT data sets (n=20) produced using previously
optimised protocols were collated for image evaluation and combined with non-
optimised Danish preset head data sets (n=20). All anonymised images
contained minimal abnormal pathology. VIEWDEX software was employed for
image display. Controlled ambient lighting of > 60 lux and 3MP primary class
monitors were employed. A radiology cohort stated their confidence in the
identification of CEC validated anatomic al structures. Image quality analysis
was performed using Visual Grading Characteristic (VGC) analyses and dose
data (CTDIvol and DLP) reviewed for the optimised (Maltese) and preset
options (Danish).
Results
Optimised Maltese protocols had been previously found to reduce
CTDIvol and DLP by 7.5% and 5.7% respectively when compared to the
original manufacturer preset scanning parameters, whilst image quality was
maintained. Mean dose values for CT head examinations were noted: Maltese
CTDIvol 33.12 mGy / DLP 461.45 mGycm and Danish CTDIvol 71.98 mGy and
DLP 1047.26 mGycm.
Conclusion
Optimised head CT protocols demonstrated dose savings of 55%
compared to the current preset Danish imaging parameters. The Danish image
evaluation is currently on-going and findings will be presented with the
completed dose analysis.
B-0625 11:06
Optimisation of the CT kidney ureter bladder protocol
J. Tabone1, D. Aquilina2, F. Zarb2; 1Sliema/MT, 2Msida/MT
(
[email protected])
Purpose: Population radiation exposure due to increased use of CT KUB in
renal colic has become significant. Therefore, efforts should be directed to
optimise CT scan parameters minimising radiation exposure whilst maintaining
diagnostic efficacy.
Methods
and Materials: Optimisation of the local protocol on a Philips
Brilliance 64 slice CT was performed in stages. Firstly, radiation dose and
image quality descriptors were established in a phantom experiment involving
systematic reduction of scan parameters on the Philips quality control
phantom. Resulting images were visually scored by radiographers (n=10) in
terms of spatial and contrast resolution identifying an exposure combination
detecting structures 2 mm in size, as smaller calc uli are clinically insignificant.
Secondly, the resulting exposure combination was applied in a clinical trial
involving 10 patients. The images produced were compared to a randomly
selected retrospective image sample (n=10) acquired with the current protocol.
Radiologists (n=5) visually graded t he image data sets based on a combination
of CEC image quality criteria for CT KUB and the unenhanced abdomen.
Image quality data was analysed using vi sual grading characteristics (VGC)
and findings considered significant at the 95% confidence interval.
Results
Mean radiation dose levels in terms of CTDIvol (1.76 mGy) and DLP
(95 mGycm) post optimisation were significantly (p < 0.05) between images
obtained from both protocols.
Conclusion
The optimised protocol was found to have similar diagnostic
quality to the current protocol with a significant reduction (70%) in both CTDIvol
and DLP.
B-0626 11:15
Preventable exposure in routine chest CT examinations: evaluation of
effective dose beyond prescribed anatomical landmarks
A. Barbara, J. Ferreira, L.J.O.C. Lanca; Lisbon/PT
Purpose: To evaluate preventable exposure dose in routine chest CT
examinations beyond prescribed anatomical landmarks and estimate extra
dose delivered to the patient.
Methods
and Materials: A sample of 102 routine adult chest CT examinations
(53 male and 49 female) was retrospectively analysed. All the scans were
acquired with a MDCT (8-slice). Using the CT-Expo software, organ effective
dose (lungs, oesophagus, heart, bone, thyroid, kidneys and adrenal glands)
were estimated. A significance level of p < 0.05 was used for statistical analysis
to test any statistical differences between the effective dose from the
performed CT scans and the desirable scans accurately planned and
referenced to the prescribed landmarks.
Results
93% of chest CT examinations were planned and acquired beyond
the prescribed anatomical landmarks. The mean effective dose in the 7 organs
for the acquired exam versus the desirable prescribed landmarks under the
routine scanning protocol was as follows: lungs (59.2 mSv vs 57.7 mSv);
oesophagus (56.2 mSv vs 57.3 mSv); heart (52.1 mSv vs 49.8 mSv); bone
(43.0 mSv vs 42.2 mSv); thyroid (13.6 mSv vs 30.3 mSv); kidneys (37.0 mSv
vs 12.2 mSv); and adrenal glands (42.8 mSv vs 29.2 mSv). Statistical
significant differences in effective dose (p < 0.05) were found in all organs,
where extra-coverage was found, except thyroid. Major differences were found
in kidneys (24.8 mSv) and thyroid (-16.7 mSv) due the fact that those organs
are located at the anatomical boundaries.
Conclusion
An accurate scanning protocol should be followed to avoid
unnecessary dose delivered to the patient.
B-0627 11:24
Do radiographers' inform parents? An investigation into disclosure of
radiation risks in paediatric CT in Ireland
K. Foley-Friel, L.A. Rainford, M.-L. Butler; Dublin/IE
Purpose: Computed tomography (CT) is widely regarded as a high radiation
dose imaging modality and its use amongst the paediatric population is rapidly
increasing. Communicating the benefits and risks of CT with parents will allow
an informed decision to be made in the child's best interest. The aim of the
study was to establish current practice surrounding radiographers' disclosure of
radiation risks to parents prior to paediatric CT examinations.
Methods
and Materials: Postal questionnaires (n= 60) were distributed to the
specialised national paediatric centres (n=3) in Ireland and three regional
hospitals performing both adult and paediatric examinations. Key topics in the
questionnaire included the practice of informing parents about radiation risks in
paediatric CT and radiographers' opinions on discussing radiation risks.
Results
A response rate of 67% was attained and of these, 20% indicated
routinely informing parents of radiation ri sks in paediatric CT, whilst 90% inform
of scan duration and 95% inform about equipment movements. In addition,
24% stated radiation risks should be discussed with parents, and 60% stated
this responsibility lies with the radiographer and referring clinician.
Radiographer responses indicated that they believed parents wished to be
informed of CT radiation risks (n= 52%).
Conclusion
The majority of radiography responses indicated that they do not
routinely disclose radiation risks to parents (n=80%), despite over 50% of
radiographers' opinion stating that parents wish to be informed of them. No
departmental protocols related to the di sclosure of radiation risks for CT
examinations performed were identified.
S270
BA C D E F G
Saturday
B-0628 11:33
Operator dependency in protocol assignment could be suppressed if
tuning the AEC strength curve from average to strong
F. Hastir1, D. Tack2; 1Ath/BE, 2Braine-L'Alleud/BE
(
[email protected])
Purpose: To investigate the impact of tuning the Automatic Exposure Control
(AEC) strength curve from "average" to "strong" on image quality, radiation
dose, and operator dependency during lumbar spine CT examinations.
Methods
and Materials: Two hospitals (H1 and H2), both using the same
scanners, were considered for two time periods (P1, P2). During P1, the AEC
curve was "average" and radiographers had to select one of two protocols
according to the BMI: "Standard" if BMI 30.0 (140 KV-280 mAs). During P2, the
AEC curve was changed to "strong" and all acquisitions obtained with one
protocol (120 KV and 270 mAs). Image quality was scored and patients'
diameters calculated.
Results
Data of 497 examinations were analysed. There was no significant
difference in mean diameters according to hospitals and periods (P >.801), and
in quality scores between periods (P >.172). There was a significant difference
between hospitals regarding how often the "large" protocol was assigned
(13/132 patients (10%) in H1, vs. 37/133 (28%) in H2) (P <.001). During P1,
CTDIvol was higher in H2 (+13%; P =.050). In both hospitals, CTDIvol was
reduced between periods (-19.2%, in H1, -29.4% in H2, P <.001).
Conclusion
An operator dependency in protocol selection, unexplained by
patient diameters or by image quality scores can increase radiation dose
during lumbar spine CT. Tuning the AEC curve from average to strong enables
suppressing this operator dependency while reducing the dose and preserving
image quality.
B-0629 11:42
Reference
dose levels in head computed tomography: a pilot study
performed during traineeship in three Portuguese health institutions
C. Figueira, C. Vieira, D. Santos, D. Santos, J. Vale, M.R.D. Santos; Aveiro/PT
(
[email protected])
Purpose: The main objectives of this study were to, during radiography
internship, verify if effective dose values associated with CT head scan were
consistent with ones referenced in the European Guidelines and to verify if the
exposure parameters were adjusted to different groups of patients namely in
paediatric examinations.
Methods
and Materials: Data were obtained in three Portuguese medical
institutions during Radiography internship. Dose-Length Product (DLP), age
and sex of 239 patients were collected and were included all head
examinations without contrast, regardless of pathology. With the DLP values,
effective dose (E= EDLP•DLP) was calculated using the normalised effective
dose for adults (EDLP=0.0023mSv•mGy-1•cm-1) and children (EDLP =
0.0040mSv•mGy-1•cm-1 - 5 years; EDLP = 0.0032mSv•mGy-1•cm-1 - 10
years??).
Results
The study sample is composed by 239 patients (53% female and
47% male) divided into 2 groups one between 17 and 100 years and other,
paediatric sample, composed of 8 cases aged between 5 and 16 years. Values
of mean effective doses obtained for adults (4,55 ±1,50mSv) were higher than
the European Guidelines values (2,41 mSv). For paediatrics patients, we
expected to find lower values than for adults and that was not observed (5
years category 4,62 ± 2,03 mSv; 10 years category 4,74±3,13 mSv).
Conclusion
Comparing with the European Guidelines we found that, for both
adults and children, the effective dose values suggested the need to optimise
practices in head CT studies.
B-0630 11:51
Colorectal liver metastasis' changes during different systematic
chemotherapy treatment
M. Kiss, B. Lombay; Miskolc/HU (
[email protected])
Purpose: Colorectal cancer is one of the most common cancer and the liver is
the most common site of colorectal metastases. There are several therapeutic
options - surgical, local or systemic chemotherapy - to manage metastases.
The statistical analysis is indispensable an d it gives very useful information to
change the best treatment.
Methods
and Materials: Between 01.10.2008 and 01.07.2013 we examined
2430 oncological patients with a known primary colorectal tumour. These
patients underwent contrast-enhanced CT (a Siemens Somatom Definition
AS+ 2x64 detector, row MDCT) and/or a contrast-enhanced liver MRI (a
Siemens Magnetom Symphony 1.5 T and a Siemens Magnetom Verio 3 T).
MATLAB software was used to made statistical analysis. We analysed the
visual appearance, the type of the chemotherapy treatment and studied how
they changed during the course of treatment.
Results
We found liver metastases in 142 patients. We divided the patients
into 3 groups, based on the type of the systematic chemotherapy treatment.
The Folfox seemed to the best method: 23 regression (decreased the size,
number of the mass and changed their structure) 12 unchanged status (no
change in the status of mass) 19 progression. De-Gramont: 6 regressions and
34 progressions. Folfiri: 34 progressions, 2 unchanged status, 12 regressions.
Conclusion
The aims of chemotherapy in unresectable colorectal liver
metastases to prolong survival, decrease the size and control symptoms.
There is no universally accepted standard therapy. Statistical analysis is very
important the clinical medicine, but it's not worth to based the treatment on
these analysis.
Author Disclosures:
M. Kiss: None. B. Lombay: None.
10:30 - 12:00 Room P
GI Tract
SS 901b
Esophageal and gastric neoplasms: new
trends
Moderators:
M. Studniarek; Gdansk/PL
D.J.M. Tolan; Leeds/UK
B-0631 10:30
Value of oral effervescent powder administration for multidetector CT
evaluation of oesophageal cancer
K.I. Ringe, S. Meyer, F. Wacker, H.-J. Raatschen;
Hannover/DE (
[email protected])
Purpose: To assess the value of oral effervescent powder administration for
detection and staging of oesophageal cancer at contrast-enhanced CT.
Methods
and Materials: 84 patients without oesophageal pathology and 52
patients with histological confirmed diagnosi s of oesophageal cancer referred
for CT were included in this prospective IRB-approved study (99m/37f, mean
age 61y). Half of the patients of each group were orally administered 3 g
effervescent powder (EP) prior to image acquisition. Oesophageal distension
was assessed (proximal/middle/distal/tumour level) by volumetry of the inner
(ID) and outer diameter (OD). Two blinded readers separately evaluated the
datasets regarding diagnosis of oesophageal cancer (yes/no) and staging (T0-
T4), if applicable. Distension results were compared (T-Test). In patients with
cancer sensitivity, specificity, negative (NPV) and positive (PPV) predictive
values were calculated. Staging results were evaluated (Cohen-k).
Results
ID and quotient ID/OD were significantly larger at all levels after EP
as compared to the control (p < 0.05; mean ID:1.1 vs. 0.42, mean ID/OD:0.34
vs. 0.13). For both readers sensitivity, specificity, NPV and PPV for detection of
cancer were as follows: 78%/78%, 98%/98%, 95%/95%, 87%/87% after EP;
60%/68%, 98%/98%, 94%/94%, 80%/83% without EP. Staging after EP was
good (k=0.838/0.674) and moderate without EP (k=0.576/0.592). Interobserver
agreement for detection and staging of tumour was very good (k=0.830) and
good (k=0.741) after EP, and good (k=0.774) and moderate (k=0.591) without
EP, respectively.
Conclusion
Oral administration of effervescent powder at CT results in good
distension of the oesophagus, and improves detection and staging of
oesophageal cancer, as compared to studies without effervescent powder.
B-0632 10:39
DW-MRI in gastro-oesophageal cancer: can ADC be considered a
prognostic biomarker and used for preoperative risk stratification?
F. Giganti, F. De Cobelli, E. Orsenigo, D. Chiari, E. Mazza, L. Albarello,
A. Ambrosi, C. Staudacher, A. Del Maschio; Milan/IT
(
[email protected])
Purpose: To investigate the role of apparent diffusion coefficient (ADC) as a
biomarker in the evaluation of the aggressiveness of gastro-oesophageal
tumours.
Methods
and Materials: Written informed consent was obtained from each
Patient. 78 Patients (54 men - 24 women; mean age 64.6 years) with biopsy-
proven disease (13 oesophageal, 13 gastro-oesophageal junction and 52
gastric cancer) were examined with a 1.5 T MR system including T1, T2 and
DWI ( b values 0-600 s/mm
2) sequences. 52/78 Patients (67%) were treated
with surgery while 26/78 Patients (33%) were submitted to neaodjuvant
therapy and then restaged with MR before surgery. All participants were
followed up for a median of 18.33 months. The role of ADC, tumour site, post-
operative T and N stage and histotype was investigated by univariate and
multivariate analysis using Cox regression model and Kaplan-Meier curves.
Results
Of the 78 Patients, 62 (80%) were alive and 16 (20%) had died.
Median overall survival was 36 ± 8.59 months (C.I. 19.1-52.8). Considering all
the variables, our results showed that ADC values below 1.4 x 10
-3 mm2/s can
S271
BA C D E F G
Saturday
predict a negative prognosis both in t he total population (n=78; p=0.010) and in
Patients directly treated with surgery (n=52; p=0.014).
Conclusion
Our study suggests the potential role of ADC as a quantitative
biomarker reflecting the aggressiveness of gastro-oesophageal lesions and
may be useful for pre-operative risk stratification considering the role of ADC
as an independent prognostic factor.
B-0633 10:48
Dual-energy CT: relationship between iodine concentration in perigastric
adipose tissue and serosa invasion for gastric cancer
G. Shi, L. Yang; Shijiazhuang/CN (
[email protected])
Purpose: To investigate the relationship between iodine concentration (IC) in
perigastric fat by dual-energy CT (DECT) and serosa invasion for gastric
cancer using histopathologic result as reference.
Methods
and Materials: 48 patients with gastric cancer undergoing
preoperative DECT and surgery were enrolled. The T staging according single-
energy venous phase images was compared with the pathological T stage.
The IC of perigastric adipose tissue was measured at arterial phase (AP) and
portal venous phase (PVP), respectively. Receiver operating characteristic was
used to determine the threshold of IC for detecting serosa invasion. The
effective radiation dose of unenhanced, arterial and portal venous phase scan
was calculated.
Results
The accuracy of T staging according single-energy venous phase
images was 58.33% (28/48). IC was significantly higher in serosa invasion
group than that of uninvaded group (AP: 0.60 ±0.34 vs. 0.12 ±0.22 mg/ml, Z=-
4.240,p=0.000; PVP: 0.83 ±0.41 vs. 0.29 ±0.23 mg/ml, Z=-4.292,p=0.000). With
a threshold of 0.25 mg/ml at AP, the sensiti vity and specificity for detecting
serosa invasion was 84.4% and 81.2%. With a threshold of 0.45 mg/ml at PVP,
the sensitivity and specificity was 87.5% and 81.2%. The effective radiation
dose of unenhanced, arterial and portal venous phase was 5.08 ±1.20,
4.39±1.46, and 4.58±2.42 mSv, respectively.
Conclusion
DECT and iodine quantification in perigastric fat is an accurate
Method
to detect serosa invasion for gastric cancer.
B-0634 10:57
Comparison of computed tomographic perfusion and 18 FDG/PET-CT in
the diagnosis of primary oesophageal cancer
M. Kantarci1, B. Genc1, E. Orsal1, H. Ogul1, Y. Aydin1, B. Pirimoglu1, A. Okur1,
A. Solak2, A. Eroglu1; 1Erzurum/TR, 2Izmir/TR (
[email protected])
Purpose: To assess the relationship between PET/CT and CT perfusion
performed for staging of primary oesophageal cancer.
Methods
and Materials: Nineteen patients undergoing PET/CT for
oesophageal cancer staging were enrolled. Subsequently, CT perfusion and
thoracoabdominal CT with contrast were performed for the oesophageal
masses. Oesophageal tumour diameters were divided into three groups: 5-
15 mm, 15-25 mm, and 25-35 mm. For each group, lymph node metastasis
and distant metastasis, as well as the mean CT perfusion and SUVmax values,
were calculated. CT perfusion parameters of blood volume (BV), blood flow
(BF), and permeability surface (BMP) were compared with the PET parameter
SUVmax. Tumour diagnosis was confirmed histopathologically in all the
patients. Correlation between the tumour grade, pathological cell types, and
the SUVmax and CT perfusion parameters calculated in tumour mass were
compared.
Results
In all stages, no significant difference was found between CT
perfusion and SUVmax values in oesophageal cancers with varying
histological types and tumour diameters (P > 0.05). There was no significant
difference between the CT perfusion parameters in the Stage 1, 2, and 3
oesophageal cancers (P > 0.05). However, there was a significant difference
between Stage 4 and the other stages with respect to the BF values
(P < 0.0213). In Stage 1, no measurable FDG uptake was detected in four
cases with a tumour diameter of 6 to 12 mm. However, CT perfusion values of
were measured in all cases.
Conclusion
The CT perfusion technique is a feasible method for evaluating
oesophageal cancers with small tumour diameters that are not amenable for
assessment with PET/CT.
B-0635 11:06
A prospective trial for the evaluation of esophageal cancer patients:
fluorodeoxyglucose (FDG) positron emission tomography
(PET)/computed tomography (CT) vs contrast enhancement (c.e). CT vs.
FDG PET/c.e.CT
L. Evangelista, A. Cervino, E. Scagliori, A. Panunzio, C. Castoro, P. Muzzio,
V. Sileni Chiarion, F. Pomerri; Padua/IT (
[email protected])
Purpose: We reported the preliminary data about the comparison of diagnostic
performance among PET/CT, c.e.CT and PET/c.e.CT in oesophageal cancer
patients.
Methods
and Materials: 60 EC patients (46 male, 62 ±12 years) who
underwent basal PET/CT plus c.e.CT in a single session, were recruited. After
60 min from the injection of FDG, a whole body PET/CT scan was acquired. At
the end of standard acquisition, a neck-thorax-abdomen c.e. CT was
performed; in particular, three c.e. phases for the liver evaluation were made.
Three specialised physicians (two radiologists and two nuclear medicine
specialists) read the images, separately. The diagnostic performances of
PET/CT, PET/c.e.CT and c.e.CT were evaluated by using the standard method
and then compared with clinical staging (by patient-based analysis).
Results
60 patients performed both PET/CT and c.e.CT while 57 of them had
all three scans. The imaging co-registration (PET and c.e.CT) was good in
88% of patients, discrete in 7% and scarce in only 5%. The agreement among
the three scans was present in 35% of subjects. In the remnant 65% of
patients, c.e.CT demonstrated more lymph node metastases than both
PET/CT and PET/c.e.CT (15 and 11%, respectively), similarly PET/c.e.CT
showed more loco-regional/distant lymph nodes and distant metastases than
PET/CT (increase in positive rate=30%). The clinical staging was recovered in
28 (41%) patients. The positive predic tive value of PET/c.e.CT was higher than
PET/CT and c.e.CT for the identification of loco-regional/distant lymph nodes
and distant metastases (81 vs.78% and 70%, respectively).
Conclusion
In EC patients, FDG PET/c.e.CT represents an accurate and
feasible method for recognising a major number of pathological findings in
comparison with PET/CT and c.e.CT.
B-0636 11:15
Diagnostic performance of MDCT in preoperative assessment for
lymphatic gastric cancer spread in the era of neoadjuvant treatment: is a
double dimensional cut-off a reliable approach?
M.A. Mazzei, C. Pozzessere, S. Guerrini, P. Mercuri, A. Parrinello,
N. Cioffi Squitieri, L. Righi, F.G. Mazzei, L. Volterrani; Siena/IT
(
[email protected])
Purpose: To validate the accuracy of MDCT in the pretreatment lymphonode
(LN) definition in patients with Gastric Cancer (GC), using a double
dimensional cut-off.
Methods
and Materials: 135 patients with primary GC, who underwent an
MDCT staging scan followed by radical surgical treatment, were
retrospectively, blindly and independently evaluated by a resident (reviewer1)
and an experienced radiologist (reviewer2). All patients were staged according
to the 3
rd edition of Japanese Classification of Gastric Carcinoma (JCGC).
Regional LNs were considered involved when the short-axis diameter (SaD)
was >/= 5 mm for nodes of level 1 and >/= 8 mm for those of the other level,
according to the distance of the LNs from the primary tumour. Cohen K test
was used to evaluate the inter-observer agreement.
Results
LN invasion was found in 83 cases (66%). The N staging overall
accuracy was 84% (reviewer1) and 90% (reviewer2). There was a statistical
significant difference between the maxi mum SaD of pathological LNs of levels
1 and 2 (p < 0.05), of intestinal and diffuse type (p < 0.01), intestinal and mixed
type (p < 0.05), and intestinal and diffuse/mixed type (p < 0.005). MDCT
diagnostic accuracy was maximised using a double dimensional cut-off, 5 mm
for LNs of level 1 and 7.7 mm for LNs of level 2. None of the T2 cases were
understaged.
Conclusion
A double dimensional cut-off for level 1 and 2 according to the
distance of the LNs from the primary tumor encourage the use of MDCT as the
only technique sufficient to assess lymphatic cancer spread in the staging of
GC.
S272
BA C D E F G
Saturday
B-0637 11:24
Differentiation of early gastric cancer with ulceration and advanced
gastric cancer using multiphasic dynamic multidetector CT
D. Tsurumaru, M. Miyasaka, Y. Nishimuta, Y. Asayama, A. Nishie, Y. Kubo,
H. Honda; Fukuoka/JP (
[email protected])
Purpose: Early gastric cancer with ulceration (EGC-U) mimics advanced
gastric cancer (AGC) because they could have similar endoscopic findings with
ulceration. The purpose of this retrospective study was to determine whether
enhancement at multiphasic dynamic multidetector row computed tomography
(MDCT) can help differentiate EGC-U from AGC.
Methods
and Materials: Seventy-four consecutive patients with pathologically
proven EGC-U (Ul-II-IV) and AGC (T2-T4a) were enrolled. Preoperative MDCT
images were obtained 40s (arterial phase), 70s (portal phase) and 240s
(delayed phase) after injection of nonionic contrast material. We compared the
CT attenuation value of EGC-U and AGC using t test. We also performed
receiver operating characteristic (ROC) analysis to determine the optimal
threshold levels to differentiate EGC-U from AGC.
Results
Of the 74 cases, 40 cases (16 EGC-U and 24 AGC) were detectable
in all three phases, which were analysed. Mean enhancement of EGC-U and
AGC peaked in the delayed and portal phase, respectively. The CT attenuation
value of EGC-U was significantly lower than that of AGC in both the arterial
(66 HU vs 107 HU, P <.0001) and portal (75 HU vs 115 HU, P <.0001) phases.
The sensitivity, specificity, and accuracy in differentiating EGC-U from AGC
were 81%, 88%, and 85%, respectively, for arterial phase and 88%, 100%, and
95%, respectively, for portal phase.
Conclusion
Enhancement at multiphasic dynamic MDCT can help
differentiate EGC-U from AGC.
B-0638 11:33
A comparison study with fluoroscopy: can CT scan predict anastomotic
leaks after gastric surgery?
T. Kim, J. Kim, C.-I. Shin, S. Kim, J. Han, B. Choi; Seoul/KR
(
[email protected])
Purpose: To assess diagnostic performance of CT for detecting anastomotic
leaks after gastric surgery comparison with fluoroscopy and to analysis clinical
role of immediate postoperative CT after gastric surgery.
Methods
and Materials: Our study consisted of 179 patients who underwent
CT and fluoroscopy after gastric surgery. We categorised patients as follows:
Group I, leak on fluoroscopy; Group II, possible leak on CT but negative on
fluoroscopy; Group III, no leak. Two reviewers independently rated the
possibility of leak on CT using a five-point scale. They evaluated presence or
absence of predefined CT findings. We also analysed the relationship between
clinical data and different groups. ROC curve analysis, Chi-Square test and
Student t-test were used for statistical analysis.
Results
AUC for detecting leak on CT was 0.886 in R1 and 0.668 in R2 with
moderate agreement ( @ = 0.482). Statistically common CT findings for leak
included discontinuity at the anastomos is site, large amount of air-fluid, and
wall thickening at anastomosis site (p < 0.05). Discontinuity at the anastomosis
was independently associated with the leak (p=0.0001). The hospitalisation
period and postoperative fasting period was longer on Group.i. than Group II or
Group III (p < 0.05). Group II showed longer total recovery period than Group
III (p < 0.05). However, surgical type (laparoscopic vs. open surgery) showed
no statistical difference on different groups.
Conclusion
Postoperative CT was useful for prediction of anastomotic leaks
using specific imaging findings. Also these CT findings can predict total
recovery period.
B-0639 11:42
MRI characteristics of anal carcinoma: analysis in a cohort of 51 patients
R. Sun, C. Durdux, P. Bauer, C. Bourillon, C.A. Cuenod; Paris/FR
(
[email protected])
Purpose: The number of anal carcinoma is increasing and MR imaging is
becoming method of choice for staging and follow-up. The purpose of this
study was to evaluate the primary MRI appearances of anal carcinoma in a
large cohort of patients.
Methods
and Materials: A review was performed on 51 biopsy-proven anal
carcinoma, where MRI was used for primary staging using T2-weighted images
(T2WI), T1WI after gadolinium chelate injection, and diffusion WI. The size, the
extent and the signal characteristics of the anal tumour, as well as the nodal
spreading were recorded. The characteristics were compared according to the
sex.
Results
Relative to the internal anal sphincter, tumours appear with very high
signal intensity (SI) in all cases on diffusion WI, and with high SI in 80% of
cases on T2WI (58% discrete, 22% frank high SI). On Gd-enhanced T1-WI
(T1+Gd), 77% tumours showed low SI, with a peripheral rim of high SI in 37%.
Lymph node metastases showed slight high SI on T2WI, and frank high SI on
T1+Gd. The median craniocaudal and circumference diameters were 4.5 cm
(IC95% [3.8-5.3]) and 213° (IC95% [182-245]). At diagnosis, women were
older than men (62 vs. 54 yo) The circumferential involvement and the number
of T4 was more important in women (360° in 37% vs. 6%, < 180° in 11% vs.
44%, T4 in 49% vs. 13%) (p < 0.05).
Conclusion
MRI is an excellent means of assessing primary anal carcinomas,
which appearances are different in older women than in young men.
B-0640 11:51
The prognostic value of tumour volume and lymph node metastasis for
oesophageal carcinoma
G. Shi, Q. Xu; Shijiazhuang/CN (
[email protected])
Purpose: To investigate the relationship between tumour volume and lymph
node metastasis, and its prognostic value of oesophageal carcinoma.
Methods
and Materials: Six hundred and seven patients (413 males 194
females,age range 26 - 78 years) received the radical resection of thoracic
oesophageal carcinoma were enrolled. According to postoperative pathology,
the number of lymph node metastasis was 0 in 371 cases, 1 in 107 cases, 2 in
51 cases, 3 in 35 cases, 4 in 43 cases. These patients' preoperative CT
images were used for tumour volume measurement. The patients were
followed up for a duration ranged from 1 to 75 months (mean 39 months). The
relationship between tumour volume, number of lymph node metastasis and
patient prognosis was investigated.
Results
The tumour volume had significant difference between N0 and N1
stage (P < 0.001). The tumour volume had significant difference between 1
lymph node metastasis group and 4 lymph nodes metastasis group (P0.05).
The tumour volume had a positive correlation to lymph node metastasis
(r=0.230,P < 0.001). The 1, 3, 5-years survival rates after the surgery date
were 83.32%, 53.33%, 36.02%, respectivel y. The survival rate was significant
difference between N0 and N1 stage (P < 0.001). Significant difference also
existed between 1 and 2 lymph nodes metastasis group (P < 0.01). Cox
regression model showed that the independent prognostic factors are: tumour
volume, the number of lymph node metastasi s, pathological type, lesion region
(P < 0.05).
Conclusion
Oesophageal carcinoma tumour volume is related to lymph node
metastasis with a positive correlation, and it is an independent prognostic
factor of post-surgery survival rate.
S273
BA C D E F G
S274
BA C D E F G
Sunday
10:30 - 12:00 Room A
Oncologic Imaging
SS 1316
Tumour staging: whole-body MRI and
MR/PET
Moderators:
M. Mayerhöfer; Vienna/AT
A.G. Rockall; London/UK
B-0641 10:30
One-step TNM staging of high-risk prostate cancer during a single MR
imaging session
V.P. Pasoglou, A. Larbi, L. Collette, L. Annet, F. Jamar, N. Michoux,
B. Vande Berg, B. Tombal, F.E. Lecouvet; Brussels/BE
(
[email protected])
Purpose: Multiparametric MRI (mpMRI) is the standard for local (T)PCa
staging. Whole-body MRI (wbMRI) is effective for the metastatic screening.
This study assesses the feasibility and value of an "all-in-one" TNM staging
combining mpMRI and wbMRI.
Methods
and Materials: 30 patients with "high-risk" PCa (PSA > 20 ng/ml,
Gleason 8, or T stage 3a) underwent wbMRI including diffusion-weighted
imaging (DWI) and prostate mpMRI in addition to the standard bone (M) and
node (N) screening [bone scintigraphy ± targeted x-rays if necessary
(BS±TXR) and contrast CT]. A "best valuable comparator" (BVC) integrating all
initial and follow-up imaging, biological, and clinical data were used to
adjudicate N and M metastatic status.
Results
Local (T) staging was feasible in all patients using ESUR guidelines.
Based on the BVC, 13 patients had metastases. Sensitivity of BS ±TXR and
wbMRI for detecting bone metastases was 89% and 100%; specificity was
90% and 100%, respectively. Sensitivity of CT and wbMRI for detecting node
metastases was 82% and 100%; specificity was 100% for both. Sensitivity of
BS±TXR combined with CT and of wbMRI for detecting metastases was 85%
and 100%; specificity was 88% and 100%, respectively. For the overall staging
of the patients as being either N0M0 or havi ng disease extension beyond the
prostate, wbMRI was superior to the BS ±TXR and CT combination
[improvement in AUC by 13.6%, P=0.0392].
Conclusion
TNM staging of PCa is feasible in less than one hour in an MRI
session combining mpMRI and wbMRI, outperforming BS ±TXR and CT for
discriminating patients with or without metastasis.
Author Disclosures:
V.P. Pasoglou: Grant Recipient; FNRS/TELEVIE GRANT. Research/Grant
Support; Fondation contre le cancer.
B-0642 10:39
Contrast enhanced total spine MRI and DWI evaluation of disease activity
in monoclonal gammopathy of undetermined significance and multiple
myeloma
P. Arcuri
1, V. Arcuri1, S. Roccia2, M. Gigliotti1, S. Molica1, G. Fodero1;
1Catanzaro/IT, 2Lamezia Terme/IT (
[email protected])
Purpose: The aim of our study was to evaluate the diagnostic value of total-
spine contrast -enhanced MRI and DWIBS (with high B-value) in the prognosis
and assessment of therapy in Monoclonal Gammopathy of Undetermined
Significance (MGUS) and Multiple Mieloma (MM).
Methods
and Materials: We studied, retrospectively, 56 patients affected of
MGUS (38) and MM (18) before treatment and after induction chemotherapy.
The results were matched with hematologic values and bone-biopsy. Were
used sequences pre- and post-contrast and DWIBS. The values were obtained
by ROIs positioned on pathologic vertebral bodies. Post-treatment changes in
ROIs Signal Intensity were compared with clinical response to therapy and with
bone-biopsy by using the Mann-Whitney U test.
Results
Lower homogeneous signal intensities in T1 Weighted images
associated with a moderate enhancement after contrast administration and
irregular high signal intensity in DWIBS were negative prognostic value in
MGUS, then changed in symptomatic MM (P < 0.001). In patients affected of
MM, the absence of significant enhancement in T1 SPIR sequence post-
contrast material injection (p < 0.002) and a low signal in DWIBS (p < 0.001),
were indicative for therapeutic efficacy.
Conclusion
The combined MRI study of MGUS patients by DWIBS and
contrast enhanced MRI of Total Spine is useful for early diagnosis and to
predict the change in MM, then supply by bone-biopsy. In MM, treatment
response patients correspond to absence of contrast enhancement and low-
signal in DWIBS.
B-0643 10:48
Tumour load in patients with multiple myeloma: ß-2 Microglobulin levels
vs whole-body MRI
M. D'Anastasi, M. Notohamiprodjo, M.F. Reiser, A. Baur-Melnyk;
Munich/DE (
[email protected])
Purpose: ß-2 microglobulin is a serum maker of tumor burden in hematologic
malignancies. We aimed to correlate serum ß-2microglobulin levels in patients
with multiple myeloma (MM) to tumor mass determined by whole-body-MRI
(WBMRI)
Methods
and Materials: We retrospectively included patients with a new
diagnosis of MM and a WBMRI prior to treatment at our institution between
2003-2011. Patients with a GFR < 60 ml/min were excluded from further
analysis since ß-2 Microglobulin levels are increased in those patients. 30
patients without renal impairment could be included. WBMRI exams (T1-w TSE
+ STIR) were assessed by two expert musculoskeletal radiologists in
consensus for focal lesions and for the presence of diffuse myeloma infiltration.
The grade of diffuse infiltration was confirmed by histology as gold standard.
Patients were staged according to the Durie & Salmon PLUS Staging System.
Results
According to WBMRI findings, 13 patients were classified as D&S
PLUS Stage I (low-grade), 6 as Stage II (intermediate-grade) and 11 as Stage
III (high-grade). As expected, most of the stage I patients (12/13) had normal
ß-2 microglobulin levels (3 mg/L). 5/6 patients in stage II and 5/11 patients in
stage III showed normal ß-2 microglobulin levels. Thus 10/17 patients (58.8%)
with substantial infiltration in the bone marrow showed false negative ß-2
microglobulin levels.
Conclusion
ß-2 microglobulin levels as a marker of tumor load may be
misleading in a number of patients with substantial myeloma infiltration in the
bone marrow. WBMRI may display the full tumor load and correctly show the
extension of myeloma infiltrates.
B-0644 10:57
The non-contrast-enhanced whole body magnetic resonance imaging in
the general population: the prevalence of abnormal findings in two age
groups
A. Cieszanowski, E. Maj, P. Kulisiewicz, I.P. Grudzinski, K. Jakoniuk-Glodala,
I. Chlipala-Nitek, B. Kaczynski, O. Rowinski; Warsaw/PL
(
[email protected])
Purpose: To assess the incidence of abnormal findings detected during non-
contrast-enhanced whole body magnetic resonance imaging (WB-MRI) in
general population in two age groups: 50 years of age (yoa) and in older
patients.
Methods
and Materials: Analysis included 666 non-contrast-enhanced WB-
MRIs performed on 1.5-T scanner between December 2009 and April 2013 in
private hospital in 451 patients 50 yoa and 215 patients > 50 yoa. Following
images were obtained: T2-STIR (whole body-coronal plane), T2-STIR (whole
spine-sagittal), T2-TSE with fat-saturation (neck and trunk-axial), T2-FLAIR
(head-axial), 3D T1-GRE (thorax-coronal, axial), T2-TSE (abdomen-axial),
chemical shift (abdomen-axial). Detected abnormalities were classified as:
unimportant (type I), potentially signifi cant, requiring medical attention (type II),
significant, requiring treatment (type III).
Results
There were 3375 incidental findings depicted in 659 (98%) subjects:
2997 type I lesions (88.8%), 363 type II lesions (10.8%) and 15 type III lesions
(0.4%), including malignant or possibly malignant lesions in 7 subjects. The
uppermost differences in the prevalence of abnormalities on WB-MRI between
patients 50 yoa and > 50 yoa concerned: brain infarction (22.2%, 45%,
respectively), thyroid cysts/nodules (8 .7%, 18.8%), pulmonary nodules (5%,
16.2%), significant degenerative disease of the spine (23.3%, 44.5%), extra-
spinal degenerative disease (22.4%, 61.1%), hepatic steatosis (15.8% vs.
24.9%), liver cysts/hemangiomas (24%, 34.5%), renal cysts (16.9%, 40.6%),
prostate enlargement (5.1%, 34.2% of males), and uterine fibroids (16.3%,
37.9% of females).
Conclusion
The incidental findings were detected in almost all subjects. WB-
MRI demonstrated that the prevalence of most of abnormalities increases with
age.
B-0645 11:06
Diagnostic accuracy of simultaneously acquired FDG-PET/MRI for the
detection of sentinel lymph node metastases in malignant melanoma
patients
M.C. Herbrik
1, T. Pöppel1, J. Grueneisen1, V. Hartung1, P. Heusch2,
T.C. Lauenstein1; 1Essen/DE, 2Düsseldorf/DE (
[email protected])
Purpose: Sentinal lymph node (SNL) biopsy as an invasive procedure is still
under discussion in malignant melanoma staging. The aim of this study was to
evaluate the diagnostic accuracy of simultaneously acquired FDG-PET/MRI for
the detection of sentinel lymph node metastases in patients with histologically
proven malignant melanoma.
S275
BA C D E F G
Sunday
Methods
and Materials: 30 consecutive patients with histopathologically
confirmed malignant melanoma and scheduled for FDG-PET/CT were
prospectively enrolled for an additional, integrated whole-body PET/MRI scan
(Biograph mMR, Siemens). The PET/MRI protocol comprised the following MR
sequences: 1) T1w FLASH pre and post-contrast, 2) T2w HASTE, 3) DWI. All
patients underwent SNL-biopsy serving as the standard of reference.
Sensitivity, specificity, PPV, NPV and accuracy of FDG-PET/MRI for the
detection of sentinel lymph node metastases was evaluated on a compartment
basis.
Results
Sensitivity, specificity, PPV, NPV and accuracy of FDG-PET/MRI for
the detection of lymph node metastases was 33%, 100%, 100%, 80% and
82%. In early stages, there was a high rate (6/30) of false negative results.
Conclusion
FDG-PET/MRI yields a relatively high diagnostic accuracy for the
detection of sentinel lymph node metastases. Results in early stages should be
rated with caution due a high rate of false negative results.
B-0646 11:15
Comparison of 18 F-FDG PET/MRI and MRI alone for whole body staging
of female patients with recurrent pelvic malignancies
J. Grueneisen, K. Beiderwellen, M. Heubner, R. Kimmig, T.C. Lauenstein,
L. Umutlu; Essen/DE (
[email protected])
Purpose: To compare the diagnostic potential of integrated 18 F-FDG
PET/MRI and MRI alone for whole-body staging of patients with recurrent
malignancies of the female pelvis.
Methods
and Materials: 20 patients with suspected recurrence of cervical or
ovarian cancer were included in our study. All patients underwent whole-body
18 F-FDG PET/MRI (Biograph mMR, Siemens). The MR protocol included 1)
T1 2D FLASH pre and post contrast, 2) T2 HASTE and 3) DWI. Two readers
evaluated separately the following datasets subsequently (A) 18 F-FDG
PET/MRI, (B) whole-body MRI including DWI, regarding (1) lesion count, (2)
lesion conspicuity (4-point ordi nal scale), (3) lesion dignity
(benign/malignant/indeterminate) and diagnostic confidence (3-point ordinal
scale). Wilcoxon's signed-rank test was applied to assess statistical
significance.
Results
Malignant lesions were present in 17 of 20 Patients. A total of 81
lesions, comprising 61 malignant and 20 benign lesions were detected.
PET/MRI offered correct and superior identification of all 17 patients with
cancer lesions, compared to MRI alone (15/17). Additionally, 18 F-FDG
PET/MRI exhibited a significant hi gher conspicuity (PET/MRI: 3.91 ±0.28;
MRI+DWI: 3.66 ±0.63) and diagnostic confidence (PET/MRI:2.79 ±0.43;
MRI+DWI: 2.15 ±0.72) in the detection of malignant lesions (p < 0.01). 18 F-
FDG PET/MRI also offered a superior conspicuity in the detection of benign
lesions (MRI: 3.23±1.14; MRI+DWI: 3.13±1.24).
Conclusion
The results demonstrate the superiority of 18 F-FDG PET/MRI in
detecting malignant and benign lesions compared to MRI alone. Thus, whole
body PET/MRI seems to be a more powerful diagnostic modality for staging of
patients with suspected pelvic malignancies.
B-0647 11:24
Whole-body [18 F]-FDG PET/MRI vs PET/CT in staging of recurrent
malignancies of the female pelvis: first results
K. Beiderwellen
1, J. Grueneisen1, V. Hartung1, P. Heusch2, B. Aktas1,
R. Kimmig1, S. Kinner1, T.C. Lauenstein1, L. Umutlu1; 1Essen/DE,
2Düsseldorf/DE (
[email protected])
Purpose: To evaluate the diagnostic potential of whole-body PET/MRI with
[18 F]-FDG in recurrent ovarian and cervical cancer in comparison to whole-
body PET/CT.
Methods
and Materials: 19 patients with suspected recurrence of pelvic
malignancies (ovarian cancer, n=11; cervical cancer, n=8) scheduled for a
contrast-enhanced PET/CT with [18 F]-FDG (Biograph mCT 128, Siemens)
were enrolled for a subsequent whole body PET/MRI examination (Biograph
mMR, Siemens). The protocol comprised: 1) T1 FLASH 2D ax. pre and post-
contrast, 2) T2 HASTE ax., 3) STIR cor., 4) DWI. The resulting datasets
(PET/CT, PET/MRI) were rated by two radiologists with regard to lesion count,
lesion conspicuity (4 point ordinal scale), dignity
(benign/malignant/indeterminate) and diagnostic confidence (3 point ordinal
scale). All available data (prior examinations, PET/CT, PET/MRI, clinical
follow-up) served as standard of reference. Mean values were compared using
Wilcoxon rank sum test.
Results
Malignant lesions were present in 16 of 19 subjects. A total of 78
lesions (malignant, n = 58; benign, n = 20) were described. Both PET/CT and
PET/MRI allowed for identification of all malignant lesions and provided
equivalent conspicuity (PET/CT: 3.86 ±0.35 PET/MRI: 3.91± 0.28). Diagnostic
confidence was significantly higher for PET/MRI in malignant lesions
(PET/CT:2.65±0.53; PET/MRI:2.78 ±0.44, p < 0.01) as well as benign lesions
(PET/CT:1.74±0.72; PET/MRI:2.18±0.76, p < 0.05).
Conclusion
Both modalities offer an equivalently high diagnostic value for
recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in
the discrimination of benign and malignant lesions. Considering the reduced
radiation dose and superior lesion discrimination, PET/MRI may serve as
powerful alternative to PET/CT in the future.
B-0648 11:33
Thoracic staging in lung cancer: [18 F]-FDG-PET/MRI vs [18 F]-FDG-
PET/CT
P. Heusch
1, C. Buchbender1, J. Köhler2, T.A. Heusner1, F. Nensa2, B. Gomez2,
H. Kühl2, V. Hartung2, G. Antoch1; 1Düsseldorf/DE, 2Essen/DE
Purpose: To compare a dedicated pulmonary [18 F]-FDG-PET/MRI protocol to
[18 F]-FDG-PET/CT for primary and locoregional lymph node staging in
NSCLC patients using histopathology as the reference.
Methods
and Materials: Twenty-two NSCLC patients (mean age 65.1 ±9.1
years) underwent FDG-PET/CT followed by a FDG-PET/MRI, including a
dedicated pulmonary MRI protocol. T- and N-staging was performed according
to the 7 th edition of the AJCC staging manual by two readers in separate
sessions for FDG-PET/CT and FDG-PET/MRI, respectively. Histopathology
was used as the reference standard for T- and N-stage. The maximum
standardised uptake value (SUVmax) was measured. SUVmax obtained from
FDG-PET/CT and FDG-PET/MRI were compared. Pearson correlation analysis
and Bland-Altman plots were performed for quantitative comparison.
Results
FDG-PET/MRI and FDG-PET/CT agreed on T-stages in 16/16 of
patients (100%), all patients were staged correctly when compared to the
Reference
standard. There was no statistically significant difference between
FDG-PET/CT and FDG-PET/MRI for lymph node metastases detection
(p=0.48). For definition of thoracic N-stages FDG-PET/MRI and FDG-PET/CT
were concordant in 20/22 patients (91%). FDG-PET/MRI and FDG-PET/CT
determined the N-stage correctly in 20/22 patients (91%) and 18/22 patients
(82%), respectively. The SUVmax of NSCLC was 12.0 ±5.7 for FDG-PET/MRI
and 10.5± 5.3 for FDG-PET/CT. SUVmax values based on FDG-PET/CT and
FDG-PET/MRI correlated well (R=0.86;p < 0.0001). Using Bland-Altman
analysis, the lower and upper limits of agreement between PET/CT and
PET/MRI were 7.42 to 4.40 for SUVmax.
Conclusion
FDG-PET/MRI using a dedicated pulmonary MRI protocol and
FDG-PET/CT are in excellent agreement on thoracic T- and N- stages and the
SUVmax of the primary tumour.
B-0649 11:42
Integrated 18F-FDG PET/MRI with a 16-channel breast coil for local and
axillary breast cancer staging: initial results on PET imaging
S. Kinner, T. Pöppel, A. Bockisch, O. Hoffmann, J. Nagarajah; Essen/DE
Purpose: Until lately, no PET/MR mammography compatible breast coil was
commercially available. We conducted this study i) to evaluate the feasibility of
FDG-PET/MRI mammography with a standard 16-channel RF breast coil and
ii) to estimate the coil influence on image quality of the FDG-PET in the setting
of local and axillary staging in breast cancer patients.
Methods
and Materials: 42 women with histopathologically proven breast
cancer underwent FDG-PET/MRM with a standard 16-channel RF breast coil
subsequent to a scheduled PET/CT. Both examinations were compared with
respect to lesion detection and staging, quan tification of lesional uptake, PET
image quality, as well as presence of artefacts. Analyses were performed both
at patient and lesion level and correlated with body mass indexes (BMI).
Wilcoxon signed-rank test, Mann-Whitney U test as well as Spearman's rank
correlation were applied if appropriate.
Results
47 lesions were detected with PET/CT vs. 46 with PET/MRM. Mean
SUV
max determined with PET/CT for tumours and lymph nodes was 6.1 ±4.7
and 5.8± 4.8 vs. 3.4 ±1.7 and 3.5± 1.9 with PET/MRI (p=0.006/ p=0.23). All 42
examinations were rated as sufficient for diagnosis with PET/CT vs. 31
examinations with PET/MRI. Mean BMI of all patients with PET/MR images
that were sufficient for the assessment was 23.9 vs.30.6 for images that were
insufficient for assessment (p < 0.001).
Conclusion
Staging of breast cancer patients with integrated PET/MRI with a
standard 16-channel breast coil is feasible. PET/MR provides acceptable
image quality with similar staging information as compared to PET/CT.
However, dedicated PET/MR breast coils are likely to improve the results,
particularly in overweight patients.
S276
BA C D E F G
Sunday
B-0650 11:51
Quantification of ADC and SUV values in tumours and lymph node
metastases of patients with cervical carcinoma in a simultaneous
MR/PET system
P. Brandmaier, S. Purz, M. Reinhardt, H. Barthel, O. Sabri, T. Kahn,
P. Stumpp; Leipzig/DE (
[email protected])
Purpose: Previous studies show discrepancies between standard uptake
value (SUV) and apparent diffusion coefficient (ADC) parameters of different
tumor entities with non simultaneous measurements on examination modalities
such as PET-CT and MRI. The objective of this study was the quantitative
evaluation of SUV and ADC values in patients with primary and recurrent
cervical cancer and suspicious lymph nodes in a simultaneous PET-MRI
system to deteriorate an expectable correlation
Methods
and Materials: We included 17 patients with cervical carcinoma and
lymph node metastases (34 lesions) who all underwent a simultaneous whole
body 18 F-fluorodeoxyglucose (FDG) PET-MRI including a dedicated pelvic
examination. Reader defined volume-of-interest (VOI) for ADC and SUV were
placed in suspicious lesions and FDG-positive lymph nodes in regions with
maximum FDG-uptake. ADC min, ADCmean, relative ADC value and SUV max, mean,
min was calculated with the M.gluteus maximus serving as reference tissue.
Correlation between multiple pairs were conducted via Pearson - correlation -
test.
Results
Local tumor lesions and lymph nodes showed average SUV mean
values of 12.7 (SE ± 1.63) and 9.4 respectively (SE ± 1.59); corresponding
ADCmean averages amounted to 1.020 x 10 -3 mm/s2 (SE ± 0.104) and 1.094 x
10-3 mm/s2 (SE ± 0.12). Significant inverse correlation (p 0.05).
Conclusion
Values of ADC and SUV show a significant inverse correlation for
ADC mean vs. SUV mean and ADC mean vs. SUVmax.
10:30 - 12:00 Room D
Chest
SS 1304
Malignancies and intervention
Moderators:
S. Vadnjal Dzonlagic; Maribor/SI
J.E. Wildberger; Maastricht/NL
B-0652 10:30
Perfusion CT: an evaluation of lung tumours following microwave
ablation
N. Parvizi, D. Chung, F. Gleeson, M. Anderson; Oxford/UK
(
[email protected])
Purpose: To assess changes in perfusion CT (pCT) parameters following
microwave ablation (MWA) of lung tumours and determine the utility of direct
visualisation of perfusion maps and pCT parameters to confirm adequate
treatment and predict local tumour progression (LTP).
Methods
and Materials: 15 patients with (7 primary and 8 metastatic) lung
tumours underwent pCT scans immediately pre and post MWA. The tumour
median size was 23 mm (range 12-52 mm). Perfusion maps of the tumours
were constructed using CT perfusion 3 software (GE, Milwaukee, USA).
Regions of interest were drawn on sequential axial sections to extract pCT
parameters from the entire tumour volume. Data was analysed using Wilcoxon
signed rank and Mann-Whitney tests. Direct visualisation of perfusion maps
pre and post MWA was performed blinded to outcome.
Results
A significant difference was only found in the median blood volume
pre and post MWA (3.59 vs 2.30 ml/100 mg, p=0.01). 3 patients developed
LTP on follow-up imaging 6 months post MWA (mean size 38 mm vs. 23 mm in
no recurrence, p=0.03). Comparison of median pCT parameters between
patients with LTP and no recurrence pre and post MWA did not demonstrate
any significant differences. Treatment adequacy was correctly categorised by
direct visualisation of the perfusion maps for 11 out of the 15 patients with
sensitivity 67%, specificity 75%, PPV 40% and NPV 90%.
Conclusion
pCT is a useful assessment tool immediately following MWA of
lung tumours. Direct visualisation of the perfusion maps may allow
identification of areas requiring further treatment at the time of the procedure.
B-0653 10:39
Two-phase dual energy CT in lung carcinoma: possible contribution of
iodine uptake calculation in mediastinal lymph nodes with different
therapy response
J. Baxa
1, J. Ferda1, A. Vondrakova1, T. Flohr2, B. Schmidt2, B. Kreuzberg1;
1Pilsen/CZ, 2Forchheim/DE (
[email protected])
Purpose: To find out potential contribution of iodine uptake change in lymph
nodes (LN) therapy response assessment.
Methods
and Materials: Retrospective analysis of 113 target LN (cross-
sectional diameter > 10 mm) in 25 patients with non-small cell lung carcinoma,
who underwent staging and follow-up (interval 6-10 weeks; mean 8.3) dual-
energy CT in arterial and venous postcontrast phase, 2-4 cycles of
chemotherapy was completed during interval. Segmentation of LN and iodine
uptake quantification (mg/ccm) prior therapy and follow-up was performed in
both phases using prototype of application (syngo.IPEPE, Siemens). Statistical
comparison of the change of iodine uptake in progressed (RECIST diameter
increased by 20% and more) LN (55), stabilised or regressing (58).
Results
The value of iodine uptake change in progressing LN in venous
phase was significantly lower (-0.35 mg/ccm; p=0.003) comparing stabilised or
regressing lymph nodes (0.05 mg/ccm). And also response of arteriovenous
shift was significantly different in reference groups (-0.77 vs. 0.31 mg/cm2,
p < 0.001). The significant difference of iodine uptake response in arterial
phase was not confirmed. (p=0.3) The direct correlation of iodine uptake
parameters and concrete volume or RECIST response was not found.
Conclusion
Our results confirmed possible feasibility of iodine uptake
determination from dual-energy CT in LN response assessment, significant
discrepancy in change of iodine uptake in mediastinal LN differently (RECIST
criteria) responding to chemotherapy was confirmed. The decrease of venous
iodine uptake should correspond to limited interstitial space in not responding
LN. Further study must confirm and specify the possible contribution in therapy
response prediction.
Author Disclosures:
T. Flohr: Employee; Siemens Healthcare. B. Schmidt: Employee; Siemens
Healthcare.
B-0654 10:48
Transcutaneous ultrasound examination of mediastinum in lung cancer
V.I. Kazakevich, L.A. Mitina; Moscow/RU (
[email protected])
Purpose: Transcutaneous chest sonography of the mediastinum in lung
cancer is considered to be an uninformative method. However, atelectasis of
the upper lobe or of the entire lung creates an acoustic window that allows one
to examine in detail the structure of the mediastinum and lung tumours to
determine tumour involvement of the mediastinum. The objective of the study
was to determine the possibility of transcutaneous ultrasound examination of
the mediastinum in patients with lung cancer.
Methods
and Materials: We have developed a technique of mediastinal
ultrasound and semiotics of the tumour ingrowth into the pericardium, large
vessels and heart in patients with lung cancer with atelectasis of the upper lobe
or entire lung. Using this procedure, 139 patients were examined. Surgery was
performed in 96 (69.1 %) of them.
Results
Using the ultrasound technique described above, the sensitivity,
specificity, and accuracy of the diagnosis of lung tumour ingrowth into the
pericardium equalled 85.7 %, 94.1 % and 90.7%, into the superior vena cava -
71.4 %, 100 % and 96 8%, into the pulmonary arteries - 93.8 %, 98.3% and
96.7 %, into pulmonary trunk - 100%, 98.5% and 98.6%, into the pulmonary
veins - 95.8 % 98.2% and 97.5 %, and into the heart - 80%, 98.7% and 97.6 %.
Conclusion
Transcutaneous chest sonography is an effective method for
diagnosing tumour involvement of organs and structures of the mediastinum in
patients with lung cancer with atelectasis of the upper lobe or entire lung.
B-0655 10:57
Transthoracic core needle biopsy under CT scan for lung malignancies:
predictive negative value and predictive factor of failure and
complications
C. Fontaine-Delaruelle
1, S. Couraud2, D. Gamondes3, E. Pradat2,
A. De Leusse2, P.-J. Souquet2, G. Ferretti4; 1Lyon/FR, 2Pierre Bénite/FR,
3Bron/FR, 4Grenoble/FR (
[email protected])
Purpose: Transthoracic core needle biopsy under CT-Scan (TTCNB) is
frequently used for the diagnosis of lung nodules. However, clinical value of
negative results was poorly investigat ed. This work aims to determine the
negative predictive value (NPV) of TTCNB as well as to investigate predictive
factors of false-negative results and complications.
Methods
and Materials: Charts of all TTCNB performed in three centres
between 2006 and 2012 were reviewed. Statistics includes binary logistic
regression for multi-variables analysis.
Results
Overall, 980 TTCNB were performed. Results were a malignant
disease in 79% (n=777), a non-malignant disease in 6% (n=54) and a negative
S277
BA C D E F G
Sunday
(or non-contributive) result in 15% (n=149). The complication rate was 34%
(life-threatening complication in 6%). In multivariate analysis, predictive factors
of complication were a target size 10 mm and a poor training of the performer.
For malignant disease diagnose, the negative predictive value was 51% and
sensibility and specificity, were respectively 89% and 99%. The predictive
factors found in multivariate analysis were a poor training of the performer and
a FDG-uptake of the target in PET-CT (OR=8.5 [95%CI 2.3-31.9]; p=0.001). In
25 cases, a second TTCNB was performed in the same target after.
Complication rate was 33% and TTCNB lead to diagnosis in 95% with a 67%
NPV.
Conclusion
Around half of the negative TTCNBs are falsely negative for
malignant disease, especially in case of FDG-uptake of the target nodule.
However, an additional TTCNB at the same target do not increased rate of
complication and leads to diagnosis.
B-0656 11:06
Three-dimensional analysis of advanced stage NSCLC: prognostic
significance of volumetric measurements
D. Colombi1, S. Diciotti2, C. Manna1, I. Montermini1, E. Fontana1, C. Rossi1,
M. Silva1, M. Tiseo1, N. Sverzellati1; 1Parma/IT, 2Firenze/IT
(
[email protected])
Purpose: To evaluate the reproducibility of the three-dimensional (3-D)
analysis of advanced stage non-small cell lung cancer (NSCLC) using a semi-
automated computer software and to determine the value of volumetric CT
measurements in predicting prognosis.
Methods
and Materials: CT scans of 43 measurable NSCLCs were included
in this study. Four observers independently measured the greatest diameter of
each lesion by using the electronic caliper on baseline and follow-up (post first
cycle chemotherapy) CT scans. In the same session, a semi-automated three-
dimensional lung cancer segmentation software commercially available, was
applied to assess both unidimensional and volumetric measurements of the
same lesions. The Bland and Altman test evaluated the interobserver variability
for each measuring system; in order to further compare reproducibility between
diameters and volumetric measurements, the latter were transformed into
equivalent diameters by assuming the tumor as having a spherical-like shape.
The value of each CT measurement change between baseline and follow-up in
predicting progression-free survival (P FS) was analysed by logistic regression
and Cox proportional hazards regression model.
Results
Volumetric measurements were the most reproducible
measurements. The only significant indicators of lower PFS were the volume
change for two observers (greatest HR, 1.57; 95% CI: 1.04-2.38), and the
maximal diameter obtained through the software for one observer (HR, 3.58;
95% CI: 1.18-10.9).
Conclusion
Our preliminary data suggests that the software-based
assessment of the lesion size seems more reproducible than the manual one
and of more prognostic value.
B-0657 11:15
Conflicting or complementary role of computed tomography (CT) and
positron emission tomography (PET)/CT in the assessment of thymic
cancer and thymoma
E. Scagliori
1, A. Panunzio1, L. Evangelista1, N. Nannini1, F. Calabrese1,
F. Pomerri1, R. Polverosi2; 1Padova/IT, 2Venezia/IT (
[email protected])
Purpose: To evaluate the role of CT and PET/CT in thymic cancer and
thymoma patients at initial staging.
Methods
and Materials: We retrospectively reviewed CT and PET/CT of 26
patients with a proven-diagnosis of thymic cancer (n=9)and
thymoma (n=17).Chest CT findings docum ented were qualitative (calcification,
peritumoral fat infiltration,pleural-pericardial effusion, degree of abutment of
vessel circumference, et al)and quantitati ve (maximum axial and longitudinal
diameter and volume).Both qualitative and semiquantitative data (standardised
uptake value, total lesion glicolysis-TLG, metabolic tumor volume-MTV)were
recovered by PET/CT.The outcome of all patients was retrieved by clinical
chart or observational follow-up.The com parisons among histological entities,
outcome and CT and PET/CT findings were evaluated using a non-parametric
analysis.
Results
PET/CT resulted positive in 15 patients with thymoma.100%of
patients with thymic cancer had a positive scan.CT was available in 5/9
patients with thymic cancer and in 3/17 subjects with thymoma.All quantitative
CT parameters were significantly higher in patients with thymic cancer than
thymoma (MAD:45vs.20 mm,MLD:69vs.21 mm and volume:77.91vs.4.52 ml;all
p < 0.05).Conversely, only MTV and TLG were significantly different in patients
with thymic cancer than the counterpart (126.53vs.6.03 cm3 and
246.05vs.20.32,respectively;both p < 0.05).After a median follow-up of 17.45
months, four recurrences of disease occurred (three in patients with thymic
cancer and one with a type B2 thymoma).Follow-up data were lost in three
subjects.CT volume in a patient with recurrent disease was 170.12 ml vs. a
median value of 10.5 ml in seven disease-free patients.MTV was higher in
recurrent than disease-free subset (143.3vs.81.13 cm3),although not
statistically significant (p=0.075).
Conclusion
Both morphological and metabolic volume can be useful for
diagnostic and prognostic meaning in thymic cancer and thymoma patients.
B-0658 11:24
Posttransplantation lymphoproliferative disorder (PTLD) of the chest: CT
and FDG-PET/CT features in twelve adults
G. Yoon, M. Kim, J. Huh; Seoul/KR (3770
[email protected])
Purpose: To investigate chest CT and 18 F-FDG-PET/CT findings of
posttransplantation lymphoproliferative disorder (PTLD) of the chest in adults.
Methods
and Materials: This retrospective study was approved by the
Institutional Review Board. Informed consent was waived. From November
2004 through February 2013, twelve patients (three female, nine male; age
range, 34-68 years; median age, 46 years) were retrospectively reviewed who
were histopathologically proved PTLD. Transplanted organs were kidney (n=6),
liver (n=4), and heart, pancreas, bone marrow (n=1), respectively. We
investigated the relationship with Epstein-Barr virus (EBV) infection and
patients' outcomes. We evaluated the locations and characteristics of the
imaging abnormalities on chest CT (n=12) and max SUV on 18 F-FDG-PET/CT
scans (n=10). The lesions were classified into the following three patterns: 1)
lymph node pattern; 2) pleural pattern; and 3) airspace pattern.
Results
The interval between transplantation and PTLD onset was 2-128
months (median, 49). EBV infection found in 10 patients (83%). Outcomes
showed complete (n=8, 67%) or partial remission (n=3) and undetermined
(n=1). The most common CT patterns were LN involvement in the mediastinal,
supraclavicular, or axillary area (n=10, 83%). The other findings were pleural
involvement as effusion (n=4, 33%), and airspace involvement; necrotic
consolidative mass or nodules (n=3, 25%) with overlapped patterns in 5 cases.
Max SUV on 18 F-FDG-PET/CT scans was 2.7~25.5 (median 7.7).
Conclusion
PTLD involving the chest manifests as three distinct patterns on
LNs involvement, pleural effusion, and nodules or masses in order of
frequency on chest CT. All patients proved lesions demonstrate increased
FDG uptake on 18 F-FDG-PET/CT.
B-0659 11:33
Cardiac mortality and morbidity in breast cancer survivors after radiation
therapy - is coronary atherosclerosis the culprit?
P. Apfaltrer
1, U.J. Schoepf2, J. Spears2, L. Pilz1, S.O. Schönberg1, T. Henzler1,
R. Vliegenthart3; 1Mannheim/DE, 2Charleston, SC/US, 3Groningen/NL
(
[email protected])
Purpose: Breast cancer survivors after radiation therapy (RT) have increased
rates of cardiac morbidity and mortality. We sought to investigate whether
accelerated coronary artery disease (CAD) is to blame by comparing coronary
calcium scores (CCS) in breast cancer survivors with and without RT.
Methods
and Materials: 306 women with history of breast cancer were
included. 67 patients underwent chest CT studies 6 months after the start of
RT (RT-group), whilst 239 patients had a CT scan either prior to or without
undergoing RT (noRT). Coronary calcium was quantified by applying a
threshold-based automated algorithm using a dedicated workstation. Statistical
analysis included the Fisher's exact test, Wilcoxon-Mann-Whitney Test, the
Siegel-Tukey Test, and Cox-regression analysis.
Results
Mean age at diagnosis for the noRT group was 57.1 ±11.9 years
versus 58.4 ±12.9 years for the RT group (p > 0.05). The groups showed no
significant differences in race, smoking history, laterality, or cancer stage. 61
noRT patients (25.5%) had a CCS of 0, compared to 18 RT patients (26.9%,
p> 0.05). The median CCS for both groups was 0 (25
th, 75th percentile: 0, 4;
p> 0.05). When adjusting for the time between diagnosis/RT and CT, RT
patients had a significantly lower risk of a positive CCS compared to noRT
patients. Results were similar after adjustment for age, race, smoking history,
laterality and stage.
Conclusion
Breast cancer survivors after RT are not more likely to show
coronary calcifications on subsequent CT imaging. Our preliminary results thus
do not support radiation-induced accelerated CAD as an explanation for higher
rates of heart disease in this group.
Author Disclosures:
U.J. Schoepf: Consultant; Bayer, Bracco, GE, and Siemens.
S278
BA C D E F G
Sunday
B-0660 11:42
Multidetector low-dose CT in assessment of predictive signs of
malignancy of undetermined lung nodules in staging of patients with
known lung cancer
A. Nasatti, D. Ippolito, P. Bonaffini, A. Casiraghi, D. Fior, S. Sironi; Monza/IT
Purpose: To assess the role of low-dose multidetector computed tomography
study in the evaluation of undetermined nodules identified on patients with lung
cancer, referred to CT staging.
Methods
and Materials: A total of 32 patients (22 males, 10 females; mean
age 67.7 years, range 30-80) with known lung cancer and undetermined
concomitant lung nodules were reviewed. All patients underwent multiple
whole body CT scan examinations, with a minimum follow-up of 12 months. All
studies were analysed in order to identify and characterise undetermined lung
nodule (up to 3 cm in diameter) besides the primary lesion, according to their
maximum axial diameter, density and structure.
Results
In 32 patients with lung cancer (31 NSCLC, 1 carcinoid) during a
follow-up period of at least 12 months (range 12-87), a total of 221 nodules
was found (mean 6.9 per patient, range 0-18). We classified 35/221 (15.8%)
nodules in 17/32 patients as metastatic in relation to dimensional growth over
time or decrease in size after treatment (mean diameter at staging CT of
6.05 mm, range 2.2-15.7 mm): 32/35 (91.4%) nodules were solid non-calcified;
2 (5.7%) non-solid and 1 (2.9%) partially solid. A total of 186/221 (84.2%)
nodules was considered as benign (mean diameter 4.3 mm, range 1.8-
14.1 mm): 140/186 nodules were solid non-calcified (75.3%), 19 (10.2%) non-
solid, 3 (1.6%) partially solid and 24 (12.9%) calcified. No cut-off value in
diameter was found to discriminate benign from malignant nodules.
Conclusion
The assessment of dimensional growth during follow-up period
remains the most reliable method to establish malignant nature of
undetermined nodules in lung cancer patients.
10:30 - 12:00 Room E1
Musculoskeletal
SS 1310
Cartilage and muscle: advanced imaging
Moderators:
J.S. Bauer; Munich/DE
L. Cerezal; Santander/ES
B-0661 10:30
MR T1rho quantification of knee cartilage lesion: correlated with
arthroscopic evaluation
H. Yang, V. Pedoia, j. Rivoire, Y. Zhang, D. Kumar, T. Link, B. Ma, X. Li;
San Francisco, CA/US (
[email protected])
Purpose: To evaluate the capability of T1rho quantification identifying knee
cartilage lesion confirmed by arthroscopy.
Methods
and Materials: 31 patients and 72 healthy controls were scanned at
3.0 Tesla. 38 cartilage lesions in 31 patients were found by arthroscopy.
WORMS was used for clinical MRI grading. T1rho value and z-scores value
(T1rho normalised to control values in matched regions) in full thickness, deep
and superficial layer cartilage were compared between compartments with and
without lesions. Student t-test was compared of WORMS, T1rho and Z-score
value between normal cartilage and cartilage lesion. ROC analysis was
compared the specificity and sensitivity of the three quantitative methods.
Results
Compared to compartment without lesions, all of WORMS, T1rho and
z-score values of cartilage significantly increased at the compartments with
lesions (p < 0.01). The AUC were 0.734 (95% CI: 0.64, 0.83), 0.746 (0.64,
0.85) and 0.775 (0.69, 0.86) among the WORMS, T1rho value and z-score
quantification separately. The AUC of the full thickness, deep and superficial
layer cartilage of z-score value were 0.775 (95% CI: 0.69, 0.86) 0.654 (0.54,
0.76), and 0.784 (0.68, 0.89) respectively.
Conclusion
T1rho quantification show a better diagnostic capability
compared clinical MRI grading in detecting cartilage lesion, especially when
using normalised z-score and laminar analysis.
B-0662 10:39
Delayed gadolinium-enhanced MRI of cartilage is superior to T1rho-
mapping in measuring cartilage-sulphated glycosaminoglycan content:
preliminary results of an in vivo validation study
J. van Tiel, G. Kotek, M. Reijman, P.K. Bos, S. Klein, J.A.N. Verhaar,
G.P. Krestin, H. Weinans, E.H.G. Oei; Rotterdam/NL (
[email protected])
Purpose: T1rho-mapping has been proposed as a non-contrast-enhanced
alternative to delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) to
quantitatively measure cartilage-sulphated glycosaminoglycan (sGAG) content.
However, no thorough validation studies comparing both techniques acquired
in vivo against a tissue reference standard for sGAG have been performed.
The aim of this study was to assess the relation of dGEMRIC and T1rho-
mapping with cartilage sGAG content in vivo in osteoarthritis patients.
Methods
and Materials: We analysed data of 8 patients from an ongoing
study in which knee osteoarthritis patients undergo T1rho-mapping and
dGEMRIC at 3 T before total knee replacement (TKR). T1- and T1rho-values of
both scans were calculated in 6 cartilage regions (medial and lateral weight-
bearing (WB) femoral condyles and tibial plateaus and non-WB cartilage of the
condyles). Femoral and tibial cartilage was harvested during TKR and
rescanned with contrast-enhanced microCT (CE-uCT), which served as
Reference
standard for sGAG since it has been shown to accurately measure
sGAG content. We analysed the correlation between T1- and T1rho-values
and CE-uCT outcomes with linear regression.
Results
T1- and T1rho-values ranged between 280-834 ms and 32-48 ms,
respectively, for dGEMRIC and T1rho-mapping. dGEMRIC outcomes had a
strong negative correlation with CE-uCT (r=-0.78;p < 0.0001;95%CI=-0.88--
0.63), while T1rho outcomes did not correlate with cartilage sGAG content (r=-
0.01;p=0.94; 95%CI=-0.35--0.32).
Conclusion
Our preliminary results suggest that dGEMRIC can accurately
measure articular cartilage sGAG content, whereas T1rho-mapping is not
suitable for this purpose. Therefore, despite the need to use a contrast agent,
we consider dGEMRIC to be superior to T1rho-mapping for quantitatively
measuring cartilage sGAG content.
Author Disclosures:
G.P. Krestin: Consultant; General Electric Healthcare. Grant Recipient;
General Electric Healthcare.
B-0663 10:48
CT arthrography of the human knee to quantitatively measure cartilage
biochemical composition: preliminary results of an in vivo validation
study
J. van Tiel, M. Siebelt, M. Reijman, P.K. Bos, J.H. Waarsing, J.A.N. Verhaar,
G.P. Krestin, H. Weinans, E.H.G. Oei; Rotterdam/NL (
[email protected])
Purpose: The ability of CT arthrography (CTa) to quantitatively measure
human cadaveric knee cartilage composition in terms of sulphated
glycosaminoglycan (sGAG) content has recently been demonstrated. Since a
validation study comparing in vivo acquired CTa outcomes against reference
standards for cartilage composition has not been performed yet, the aim of the
present study was to perform such a validation in humans with knee
osteoarthritis (OA).
Methods
and Materials: We analysed data of 8 patients from an ongoing
study in which knee OA patients (Kellgren and Lawrence grade 2-4) undergo
CTa before total knee replacement (TKR). Mean X-ray attenuation values were
calculated in 6 regions of interest (ROI) of the articular cartilage (medial and
lateral weight-bearing (WB) femoral condyles and tibial plateaus and non-WB
cartilage of the condyles). Femoral and tibial cartilage was harvested during
TKR and rescanned with contrast-enhanced microCT (CE-uCT), which served
as surrogate reference standard for sGAG since it has been shown to
accurately measure sGAG content. We analysed the correlation between CTa
X-ray attenuation and CE-uCT outcomes with linear regression.
Results
X-ray attenuation values of the different ROIs in the tibiofemoral joint
ranged from 150 to 450 Hounsfield Units. Outcomes of CTa had a strong
correlation with reference CE-uCT, representing sGAG content of cartilage
(r=0.81;< 0.0001;r
2=0.65).
Conclusion
Our preliminary results suggest that CTa can accurately measure
sGAG content of articular cartilage in human knee joints in vivo. The coefficient
of determination, however, is only moderate and therefore CTa outcomes are
likely to be also influenced other composites of cartilage, e.g. collagen.
Author Disclosures:
G.P. Krestin: Consultant; General Electric Healthcare. Grant Recipient;
General Electric Healthcare.
B-0664 10:57
Biochemical imaging and morphological analysis of the lower extremity
joint cartilages of 44 ultra-marathoners with a mobile MRI during a 4500
km trans-continental-run
U.H.W. Schütz
1, M. Ehrhardt1, D. Schoss1, A. Reiner1, S. Göd2, M. Brix1,
S. Trattnig2, M. Beer1, C. Billich1; 1Ulm/DE, 2Vienna/AT
(
[email protected])
Purpose: The TransEuropeFootRace (TEFR) was one of the longest ultra-
marathons. The results on investigations on the cartilage layers of the lower
extremity joints are shown in the progress of the TEFR, proofing the
hypothesis, that running nearly 4,500 km alters the joint cartilage in an extent
towards relevant cartilage injury improving the risk of osteoarthritis.
Methods
and Materials: 44 TEFR-participants were accompanied by a mobile
1.5 T MR-imager mounted on a 40-tonnes truck, when running 70.1 km per
stage in 64 days. They got repeated MRI on knee, ankle and midtarsal joints in
regular intervals. The protocols used were a TIRM, a PDw TSE fs and a T2*
S279
BA C D E F G
Sunday
GRE mapping sequence. ROIs were selected manually on T2* images.
Morphological evaluation was done on the PDw and TIRM sequences.
Results
Compared to start, there are significant increases of mean T2* values
detectable in all cartilage layers of all evaluated joints (except: femoropatellar
joint) for all measurement intervals during the TEFR (p < 0.05). We found
relevant decreasing of mean T2*values in the cartilages of joints with axial
loading after 2,000 km distance run. No relevant changes regarding
morphological criteria like thickness of carti lage layers were seen for any of the
investigated joints.
Conclusion
It could be shown for the first time in vivo that after early
degradation human cartilage matrix is able to develop anabolic changes with
de novo re-synthesis of glycosaminoglycanes under ongoing multistage
ultramarathon burden in axial loaded lower extremity joints. Therefore, there is
no distance limit in running regarding human joint cartilages.
B-0665 11:06
Quantitative MR imaging of the ankle: the effect of axial traction on
cartilage T2 relaxation times and cartilage diffusion values
P.M. Jungmann, T. Baum, C. Schaeffeler, M. Sauerschnig, A. Mann,
C. Ganter, E.J. Rummeny, K. Woertler, J.S. Bauer;
Munich/DE (
[email protected])
Purpose: To assess the impact of axial traction during 3.0 T MR imaging of the
ankle on quantitative cartilage imaging parameters.
Methods
and Materials: Ankle MR images were acquired in 8 volunteers with
and without axial traction (6 kg). For morphological evaluation, coronal and
sagittal T1-weighted (w) turbo spin echo (TSE) sequences with a DRIVE pulse,
sagittal fat-saturated intermediate-w TSE sequences and 3D gradient echo
sequences were acquired. For quantitative assessment of cartilage
degradation, segmentation was performed on three different sagittal
sequences: 2D multislice-multiecho (MSME) SE T2-w, steady-state free-
precession (SSFP) T2-w and SSFP diffusion-weighted imaging (DWI). Paired t-
tests were used for statistical analysis. Coefficients of variation (CV) were
calculated to assess reliability of two independent observers.
Results
Cartilage surface delineation was superior with axial traction
(P < 0.05), especially on coronal T1-w images. T2 differed significantly with and
without axial traction (tibia, P=0.016; talus, P=0.007). While without traction,
tibial and talar T2 was not significantly different (mean ±SEM, 43.5 ±1.6 ms
versus 44.1 ±0.9 ms, P=0.658), with axial traction, T2 was lower at the tibia
(40.0±1.6 ms versus 46.1 ±1.0 ms, P < 0.001). SSFP T2 was significantly
different between tibia and talus in MR scans with axial traction (20.3 ±1.7 ms
versus 24.5 ±1.0 ms; P=0.005; normal scans, P=0.289). SSFP DWI values at
the talus differed significantly (P=0.035). Reproducibility was better for images
with axial traction (tibia T2, CV, intrareader 1.5% and 1.7% versus 1.7% and
3.7%, interreader 3.4% versus 5.2%).
Conclusion
Axial traction of the ankle during MR imaging better visualised the
cartilage surface, improved compartment discrimination and reproducibility of
quantitative cartilage matrix degradation parameters.
B-0666 11:15
Longitudinal follow-up of changes regarding specific body tissue
composition of 44 ultra-marathoners with a mobile whole body MRI
during a 4,500 km trans-continental-run
U.H.W. Schütz
1, C. Billich1, M. Beer1, J. Machan2; 1Ulm/DE,
2Tübingen/DE (
[email protected])
Purpose: The results of differentiated measurements of changes in body
composition during the TranseuropeFootrace (TEFR) using a mobile whole-
body MR-imager are presented and the proposed influence of visceral and
somatic adipose and lean tissue distribution on performance tested.
Methods
and Materials: 22 participants were randomly selected for the
repeated MR-measurements (intervals: 800 km) with a mobile 1.5 Tesla MR
scanner mounted on 40-tons truck during the 64-stage 4,486 km TEFR. A
validated MRI protocol was used: T1w TSE, TE 12 ms, TR 490 ms, ST 10 mm,
SD 10 mm. For topographic tissue, segmentation and mapping a modified
fuzzy c-means algorithm was used. A semiautomatic postprocessing of whole
body MRI datasets allows reliable analysis of the following tissue
compartments: Total, somatic and visceral adipose (TAT,SAST,VAT) and lean
(TLT,SLT,VLT) tissue. Adipose and lean tissue was also differentiated
regarding trunk and extremities.
Results
Adipose tissue showed a significant decrease at all measurement
times for TAT, SAST and VAT. Lean tissues decreased until the end of the
race, but not significantly. The mean relative volume changes at the last
measurement compared to the start were: TAT 41.3%, SAST 48.7%,
VAT64.5%, intraabdominal adipose tissue 67.3%, mediastinal adipose
tissue 41.5%, TLT1.2%, SLT1.4%.
Conclusion
Even lean tissue volume (mainly skeletal muscle) decreased due
to the unpreventable chronic negative energy balance during TEFR. VAT has
the fastest and highest decrease compared to SAST and lean tissue
compartments during the race. It seems to be the most sensitive morphometric
parameter regarding the risk of non-finishing a transcontinental ultramarathon
and shows direct relationship to prerace-performance.
B-0667 11:24
Correlation between muscle cross-sectional area measurement and total
vastus medialis volume in patients with anterior cruciate ligament
reconstructions
M. Marcon
1, B. Ciritsis2, C. Laux2, M.A. Fischer2, G. Andreisek2, E.J. Ulbrich2;
1Udine/IT, 2Zurich/CH (
[email protected])
Purpose: Vastus medialis atrophy is a clinical indicator for postoperative knee
function in patients with anterior cruciate ligament (ACL) reconstructions.
Purpose was to develop a simple estimation for total muscle volume in patients
with ACL-reconstructions.
Methods
and Materials: Prospective IRB approved study with written
informed patient consent. Both thighs of thirty-four consecutive patients with
ACL-reconstructions (men, 22; women, 12) were imaged at 1.5 T using an
axial T1-weighted as well as axial 3D spoiled dual gradient-echo (LAVA FLEX)
sequences with automated reconstruction of pure fat-only and water-only
images. Total muscle volume of both vastus medialis muscles (n=68) was
determined by one experienced reader on the water-only images, where
muscle borders were more clearly i dentifiable, using dedicated software
featuring semi-automatic segmentation with linear interpolation (Myrian 1,
Intrasense, France). In addition, the muscle`s cross-sectional area was
measured on single slices at two different levels, 15 cm (CSA-Up) and 6 cm
(CSA-Low) above the knee joint. The correlation between total muscle volume
and both cross-sectional area measurements was evaluated using Pearson
correlation-coefficient. p <.05 indicated statistical significance.
Results
The vastus medialis' total muscle volume was 457.2 ±132.6 cm3
(mean±SD)(range, 197.3-771.2). The mean ±SD CSA-Up was
2405.2±664.4 mm2 (range, 1241-3969) and the mean ±SD CSA-Low was
1211.7±416.4 mm2 (range, 431-2199). Pearson correlation showed a weak
linear relationship between total muscle volume and CSA-Low (r=.347,
p=0.002), but a strong linear relationship between total muscle volume and
CSA-Up (r=.949, p <.001).
Conclusion
Muscle cross-sectional area measurements 15 cm above the
knee joint allow simple estimations of the total vastus medialis muscle volume.
B-0668 11:33
MRI muscle fat quantification with 3 point Dixon in 20 patients with
muscular dystrophy and its correlation with clinical scales
A. Guisasola Iñiguez, R. Fernández-Torron, J. Alustiza, E. Fernandez,
D. Otaegui, J. Poza, A. Saenz, E. Salvador, A. Lopez de Munain;
San Sebastian/ES (
[email protected])
Purpose: Muscle magnetic resonance imaging (MRI) provides information on
the distribution and evolution of limb girdle muscular dystrophies (LGMD). In
the last years quantitative sequences like 3-point Dixon technique have been
developed to measure muscle fat fraction.
The aim of this study is to quantify muscle fat content in lower limb muscles of
ambulant patients with LGMD 2 A and to determine its correlation with
functional scales.
Methods
and Materials: Cross-sectional study of 20 ambulant patients with
molecularly confirmed LGMD2 A. Gardner-Meldwin-Walton and Vignos scales
were assessed by a neurologist to determine clinical severity. A 3-point Dixon
sequence (TE 2.3-4.6-6.9 ms, FOV 375, matrix 376/384, thickness 2 mm,
acquisition time: 5.10 minutes) was performed in a 1.5 T Achieva Philips
scanner. Muscle fat fraction was calculated drawing a region of interest
covering cross-sectional area in three different slices per muscle bilaterally (ten
muscles in thigh, eight in calves). Correlations between clinical scales and
muscle fat fraction were determined with Spearman's rho coefficient.
Results
Mean age was 24.30 ± 9.35 years. Mean clinical severity was
4.65 ± 2 and 3.68 ± 1.87 in Gardner-Meldwin-Walton and Vignos scales. A
significant correlation (p < 0.05) was detected between the mean fat muscle
content of all muscles and Gardner-Meldwin-Walton (r-square 0.91) and
Vignos (r-square 0.86) scale. This correlation was also found separately in the
muscles of thigh (r-square 0.9) and calves (r-square 0.86).
Conclusion
Muscle fat content measured with 3-point Dixon provides a high
correlation with clinical severity of ambulant LGMD2 A patients and could be a
useful biomarker.
Author Disclosures:
R. Fernández-Torron: Grant Recipient; Rio Hortega Grant, Ministry of Health
and Science. Research/Grant Support; SAIOTEK programme of Basque
Government.
S280
BA C D E F G
Sunday
B-0669 11:42
Real-time elastosonography RTE contribution in assessing muscle
spasticity in patients with spinal cord injury: preliminary report
P. De Petro, S. Pozza, A. De Marchi, F. Carlo, M. Actis, L. Romano,
P. Balocco; Turin/IT (
[email protected])
Purpose: This study aims to present our experience of 9 cases of spinal cord
injury patients (SCI), using ultrasonography and real-time elastosonography
(RTE) in assessing muscle spasticity versus fibrotic muscle component.
Methods
and Materials: We examinates 9 patients with incomplete (2
patients) or complete (5 patientes) SCI, 2 women, 7 men using an ultrasound
system with array tranducer F-75 Aloka Hitachi UST-5411, 2-18 MHz. We
investigated intrinsic stiffness changes using RTE in the triceps sural muscle:
the relaxed muscle structures appear mostly soft (yellow-red), while contracted
or degenerated muscle fibers appear hard (blue). Elastosonography findings
were converted in a semiquantitative measurement method (ratio) from 0 to 4
(increase stiffness to reduce stiffness respectively) between the area of interest
and a reference area in our case standoff pad. Clinical and functional
evaluations were performed (ROM, Ashworth scale, WHS). Statistical analysis
included Pearson r calculation, and regression line analysis.
Results
We observed, throughout statistical analysis, an opposite correlation
(r= -0.595) between clinical data of ROM evaluation and RTE value of muscle
flexibility (y = -0.039x + 4.902 R² = 0.354).
Conclusion
The muscle flexibility is an important component to quantify grade
of spasticity in SCI patients. In this preliminary report, a decreased ROM
matches with an increased ratio (mostly soft muscle). It could be a fundamental
component to choose the best treatment for this typology of patients. For a
better evaluation of muscle component (spastic or fibrotic) we need to continue
with a more representative and homogeneous sample.
B-0670 11:51
T1rho values and T2 mapping using 3.0-Tesla MRI and arthroscopic
findings correlations of hip joint cartilage in patients with early
osteoarthritis caused by femoroacetabular impingement (FAI)
H. Goto
1, S. Hashimoto1, Y. Iwama2, N. Kanzaki1, N. Aoyama1, Y. Ohno1,
K. Sugimura1; 1Kobe/JP, 2Nishinomiya/JP (
[email protected])
Purpose: The aim of this study was to examine correlations among the pain
score, the hip arthroscopic findings and to evaluate the sensitivity of T1rho and
T2 mapping in the quantification of early damaged hip joint cartilage in FAI
patients.
Methods
and Materials: Twenteen patients with clinical signs of FAI (5 cam-
type and 7 mixed-type) were examined using 3.0-T magnetic resonance
imaging (MRI). T2 mapping and T1rho values were calculated from sagittal-
oriented gradient-multi-echo sequences. Region of interest analysis was
manually performed on consecutive slices. Median T2 mapping values and
T1rho values of both the superior damaged cartilage areas were compared. In
addition, all patients underwent hip arthroscopy, and the Multicenter
Arthroscopy of the Hip Outcomes Research Network (MAHORN) score were
calculated and compared with T1rho and T2 mapping. The significance of
differences between the T1rho values and the T2 mapping of cartilage were
determined using a paired t-test and non-parametric regression analysis. P
values < 0.05 were considered statistically significant.
Results
The pain score was significantly correlated with T1rho values (r=0.96,
*p < 0.01) but no significant correlation was observed with T2 mapping (r=-
0.12,p=0.67). The cartilage delamination of MAHORN score was significantly
correlated with T1rho values (normal cartilage vs injure cartilage; 85.22 vs
102.42, *p=0.02) but no significant correlation was observed with T2
mapping (46.64 vs 50.10, p=0.78).
Conclusion
T1rho has the potential to evaluate the degree of degeneration of
hip joint cartilage in patients with early osteoarthritis caused by FAI.
10:30 - 12:00 Room E2
Abdominal Viscera
SS 1301
Advanced imaging of liver neoplasms
Moderators:
L.S. Guimaraes; Porto/PT
M. Laniado; Dresden/DE
B-0671 10:30
Using gadoxetic acid-enhanced liver MR imaging to predict histologic
features and treatment response in liver metastasis from breast cancer:
Preliminary results
M. Ku, C. Lee, J. Kim, Y. Park, J. Lee, J. Choi, K. Kim, C. Park; Seoul/KR
(
[email protected])
Purpose: To retrospectively identify gadoxetic acid-enhanced MRI findings of
liver metastasis from breast cancer that correlate with histologic factors of
breast cancer, and to evaluate the relationship between MRI findings and
treatment response.
Methods
and Materials: This study was approved by our institutional review
board and the requirement for informed consent was waived. Thirty-four
metastatic lesions of 20 breast cancer patients with liver metastasis were
included. Appearance on hepatobiliary phase (HBP) and T2WI, and arterial
enhancement pattern were evaluated.
Histologic factors including histologic subt ype (luminal A, luminal B, HER2, and
basal-like subtypes), mutation of p53, Ki67 labeling index, and tumor grade of
breast cancer were reviewed and analysed to identify histologic factors that
correlate with MRI findings.
In 11 patients who had undergone chemotherapy for liver metastasis, sixteen
metastatic lesions were classified into "responder" and "non-responder", and
also analysed to evaluate correlation between treatment response and MRI
findings.
ADC value and lesion-to-liver SI ratio were measured for each lesion and
compared between different groups.
Results
There was no histologic factor that significantly correlated with
gadoxetic acid-enhanced MRI findings, and ADC value and SI ratio did not
correlate with any histologic factors. "Target" appearance on HBP was more
frequent in "non-responder" than "responder"[11/12 (91.7%) vs. 1/4 (25%),
p=0.027]. ADC value and SI ratio were not significantly different between
"responder" and "non-responder"(1.13 ±0.21 vs.1.02± 0.19×10
-3 mm2/sec,
p=0.396, and 0.51±0.13 vs.0.55±0.14, p=0.865, respectively).
Conclusion
Metastatic lesions from breast cancer showing "non-target"
appearance on HBP of gadoxetic acid-enhanced MRI tend to respond better to
chemotherapy than those showing "target" appearance.
B-0672 10:39
Assessment of response to chemotherapy in patients with liver
metastases from colorectal cancer: value of diffusion-weighted MR
imaging
T. Zahel, E.J. Rummeny, K. Holzapfel;
Munich/DE (
[email protected])
Purpose: To evaluate diffusion-weighted MR imaging (DWI) in assessing
response to chemotherapy in patients with liver metastases from colorectal
cancer.
Methods
and Materials: Thirty-three patients (24 men, 9 women, mean age
65.5 years) with liver metastases from colorectal cancer underwent MR
imaging (1.5 T Magnetom Avanto, Siemens) before and after 8 weeks of
systemic chemotherapy. The MR imaging protocol comprised DWI using a
single-shot echo-planar imaging sequence (TR = TE =69 ms, Matrix
192x144, slice thickness 5 mm, iPAT factor = 2, b values 50, 300 und 600
s/mm²) combined with navigator echo technique. ADC (apparent diffusion
coefficient)-values of metastases were calculated before and after
chemotherapy. Regions of interest entailed (a) the whole lesion and (b) the
periphery of lesions. Response of metastases to chemotherapy was assessed
using the Response Evaluation Criteria in Solid Tumors.
Results
One-hundred-four metastases (72 responding and 32 non-
responding) were analysed using DWI. Responding (1.28 vs. 1.41) and non-
responding lesions (1.4 vs.1.46) had higher ADC-values after chemotherapy
using whole tumor regions of interest; these were only significant in responding
lesions (p = 0.001; nonresponding lesions p =0.21). ADC-values in the
periphery of metastases showed a significant increase in responding lesions
(1.01 vs. 1.20; p = 0.0116). ADC value increase of nonresponding lesions was
not significant (1.07 vs.1.16 p = 0.4586).
Conclusion
Following chemotherapy, responding lesions showed a
significant increase of ADC values w hen measured as a whole region of
S281
BA C D E F G
Sunday
interest and also when measured in the periphery. Nonresponding lesions did
not show a significant difference.
B-0673 10:48
Liver lesion margin intensity slope to distinguish cysts, responder and
non-responder colorectal metastases following anti-angiogenic therapy
V. Yaghmai, A.R. Seyal, F.D. Gonzalez-Guindalini, K. Parekh, Y. Velichko,
T. O'Donnell; Chicago, IL/US (
[email protected])
Purpose: To evaluate liver margin intensity slope (LMIS)as a potential imaging
biomarker for distinguishing responder and non-responder colorectal liver
metastases from cysts after anti-angiogenic therapy.
Methods
and Materials: The HIPAA compliant study was IRB approved. Two
patient cohorts were selected. First cohort comprised of 45 colorectal liver
metastases in 21 patients treated with bevacizumab with post-treatment
abdominal CT and a FDG-PET scans. Second cohort comprised of fifteen
patients with 19 liver cysts imaged by contrast-enhanced MDCT. Volumetric
segmentation of liver lesions was performed using semiautomated
segmentation software. Lesion margin intensity slope, a quantitative measure
of margin sharpness, where sharper margins of low-density lesion result in
greater negative value, was measured for liver metastases and cysts. LMIS of
post-treatment liver metastases was compared with their FDG-PET response
and with LMIS of cysts. One-way analysis of variance was used for initial
analysis with Student-Newman-Keuls test for multiple comparisons.
Results
Based on FDG-PET 34/45 (75.5%) lesions showed response and
11/45 (24.4%) lesions were nonresponders. Mean LMIS values for
nonresponders, responders and liver cysts were - 8.2 ± 4.3, - 19 ± 3.4 and -
22.27 ± 4.8 HU/layer, respectively (p < 0.0001). On multiple comparisons, all
three groups were significantly different from each other though, responder
lesions had less mean difference in LMIS value from cysts when compared
with nonresponders (11.52 HU/layer for responders vs. 18.9 HU/layer for
nonresponders).
Conclusion
Integration of LMIS may help differentiate liver cysts from
metastases. It is a potential biomarker of response to antiangiogenic treatment
in colorectal liver metastases.
Author Disclosures:
A.R. Seyal: Research/Grant Support; Educational Grant Support from
Siemens Healthcare. F.D. Gonzalez-Guindalini: None. K. Parekh:
Research/Grant Support; Educational Grant Support from Siemens
Healthcare. Y. Velichko: None. T. O'Donnell: Employee; Siemens Medical
Solutions.
B-0674 10:57
Dyna-CT vs MDCT in the evaluation and detection of hypervascular HCC
P. Lucatelli, M. Di Martino, E. d'Adamo, A. d'Adamo, M. Bezzi, M. Corona,
F.M. Salvatori, C. Catalano; Rome/IT (
[email protected])
Purpose: To evaluate the feasibility and the reproducibility of Dyna-CT in the
evaluation of the contrast-to-noise ratio compared with MultiDetector-
Computed Tomography (MDCT).
Methods
and Materials: Twenty consecutive cirrhotic patients, scheduled for
transarterialchemoembolisation-(TACE), planned on the basis of MDCT,
underwent Dyna-CT immediately before treatment. 64-slice CT was performed
with 0.6×64 mm collimation, 3-mm section thickness, 250 mAs, 120 kVp. A
triple-phase protocol was utilised with scans initiated at 18s, 60s and 180s after
a trigger threshold of 150 HU above baseline was achieved in aorta. Dyna-CT
was performed after having positioned a Sim-1 catheter beyond the
gastroduodenal artery. Injection rate and volume of contrast media were left to
the operator choice according to vascular anatomy. The contrant agent was
diluted up to 40% with saline. Intra-arterial injection lasted 12 sec (4 sec delay
+8 sec of acquisition).Two radiologist in consensus evaluated two data sets of
images on a dedicated workstation (Leonardo; Siemens Medical Systems).The
mean CT numbers of HCC nodules were assessed by manually placing
circular or ovoid ROIs, which were drawn to encompass as much of the lesion
as possible. CNR was calculated for both technique as follow: ROIt - ROIl/ SDn
where ROIt is the mean attenuation of the tumor, ROIl is the mean attenuation
of the non-tumorous liver parenchyma, and SDn is the image noise.
Results
No statistical significant differenc e was reported between MDCT and
Dyna-CT in the evaluation of HCC's CNR (p >.05).
Conclusion
Dyna-CT is feasible and reproducible compared to MDCT in the
assessment of hypervascular HCC.
B-0675 11:06
Volumetric assessment by 7 Tesla liver magnetic resonance (MR) in mice
to evaluate a novel therapy for colorectal cancer (CRC) metastases
P. Marra, A. Esposito, G. Sitia, M. Catarinella, T. Canu, L.G. Guidotti,
F. De Cobelli, A. Del Maschio; Milan/IT (
[email protected])
Purpose: Tie2-expressing monocytes (TEMs) are tumor-associated
macrophages with pro-angiogenic activity, normally recruited in primitive and
metastatic liver lesions with neo-angiogenesis. As interferon- ' (IFN') is known
to play antitumoral effects, we engi neered TEMs to express and selectively
deliver IFN ' to liver metastases. Antitumoral efficacy was assessed by MRI
volumetric analyses in a mouse model of liver CRC metastases.
Methods
and Materials: Liver metastases were induced injecting 5x10 3 CT26-
GFP cells through the splenic vein in 30 CB6 F1 mice: 14/26 were previously
transplanted with TEMs engineered to express IFN ' under the Tie2 promoter
(IFN-group); 12/26 were transplanted with engineered TEMs expressing green-
fluorescent-protein under the Tie2 promoter (Placebo-group); 4/26 control mice
were not manipulated before metastases induction (Control-group). At 14-21-
34 and 54 days all mice underwent in-vivo 7-Tesla liver-MRI with hepatocyte-
specific contrast agent (EOB-DTPA) for the volumetric assessment of
metastases.
Results
The incidence of liver metastases was lower in IFN-group than in
Placebo and Control groups both at 14 (0%vs57%vs50%; p < 0.05) and at 34
days (11%vs100%vs100%; p=0.002) from CT26-GFP cells injection. 3 IFN-
mice that developed metastases at day 21 were cured and presented no
metastases at day 54. Average tumor volume was significantly lower in IFN-
group than in Placebo and Control groups with a mean value between time-
points respectively of 1.53vs128.86vs38.92 mm
3 (p < 0.01). At day 54 all
Placebo- and Control-mice were dead vs only 11% of IFN-mice (p=0.001).
Conclusion
Hepatic deliver of IFN ' by engineered TEMs reduces the
incidence and volume of CRC metastases at serial MRI analyses and improves
survival in experimental mice.
B-0676 11:15
Preoperative assessment of colorectal liver metastases after
chemotherapy: a combined approach of diffusion-weighted MR imaging
with b-multiple SE-EPI and Gd-EOB-DTPA MR sequences at 3 T-device
P. Boraschi, F. Donati, L. Urbani, R. Gigoni, G. Gherarducci, F. Pacciardi,
G. Masi, F. Falaschi, C. Bartolozzi; Pisa/IT (
[email protected])
Purpose: To determine whether diffusion-weighted MR imaging (DW-MRI)
with b-multiple SE-EPI could improve the diagnostic performance of Gd-EOB-
DTPA-enhanced MRI (dynamic and hepato-biliary phase sequences) in the
preoperative assessment of colorectal liver metastases in patients previously
undergone chemotherapy.
Methods
and Materials: Twenty patients with colorectal cancer and focal liver
lesions underwent MR imaging at 3 T-device (GE DISCOVERY MR750;GE
Healthcare) after preoperative chemotherapy. Three images sets were
separately reviewed by two observers in conference: 1, DW-MRI using a spin-
echo echo-planar sequence with multiple b values (150, 500, 1000, 1500
sec/mm²); 2, Gd-EOB-DTPA Lava-flex sequence including both dynamic and
hepato-biliary phase; 3, combined DW-MRI and Gd-EOB-DTPA images. The
MRI findings were correlated with surgery and histopathology, which was our
gold standard. Only clear benign lesions at intraoperative ultrasound remained
unresected. Statistical analysis was performed on a per-lesion basis.
Results
A total of 146 hepatic lesions were detected; of these, 106 were
metastases (72.6%), whereas the remaining 40 (27.4%) were characterised as
benign lesions (cysts and hemangiomas). Image set 1 correctly identified 92
out of 106 metastases (sensitivity 86.7%, specificity 50%, diagnostic accuracy
76.7%), image set 2 correctly detected 98 out of 106 metastases (sensitivity
92.4%, specificity 70%, diagnostic accuracy 86.3%), and image set 3 correctly
diagnosed 104 out of 106 metastases (sensitivity 98.1%, specificity 95%,
diagnostic accuracy 97.2%). Differenc es were statistically significant
(p < 0.001).
Conclusion
DW-MRI with b-multiple SE-EPI significantly increases the
diagnostic performance of Gd-EOB-DTPA-enhanced 3 T MRI in the
preoperative assessment of colorectal liver metastases.
S282
BA C D E F G
Sunday
B-0677 11:24
Performance of gadoxetic acid-enhanced MRI for the differentiation of
FNH and HCA: a single centre experience
C. Perez Fernandez, T. Denecke, C. Grieser;
Berlin/DE (
[email protected])
Purpose: Evaluation of enhancement characteristics of focal nodular
hyperplasia (FNHs) and hepatocellular adenomas (HCAs) with gadoxetic acid-
enhanced magnetic resonance imaging (MRI).
Methods
and Materials: Eighty-six patients who underwent MRI at 1.5 T were
retrospectively included. Examination protocol contained: T1-in- and opposed
phase; T2-weighted UTSE and fat-saturated T1-weighted (WATS; LAVA) with
and without contrast media (Gd-EOB-DTPA; arterial, portal venous, venous
and hepatobiliary phase. Standard of reference was surgical resection (n=53)
or biopsy (n=15) available for 114 lesions. All cases were read by two
independent radiologists in consensus. Lesi on intensity was visually compared
with the intensity of the surrounding liver parenchyma. Furthermore, relative
signal intensity (SI) values (%) in contrast to native SI values were recorded for
the different contrast phases.
Results
114 lesions (FNHs, n=44; HCAs, n=70) were evaluated. On
unenhanced MRI, presence of fat (P < 0.001; accuracy=54%), haemorrhage
(P=0.071; accuracy=57%) and "wash-out'' were indicative for HCA (P < 0.001;
accuracy=63%), whereas the presence of a central scar was indicative for FNH
(P < 0.001; accuracy=85%). Regarding signal intensities on hepatobiliary
phase images, an iso-/hyperintense appearance of FNHs and hypointensity of
HCAs were the best discriminators between both entities (P < 0.001;
acc=92%).
Conclusion
An iso-/hyperintensity of FNHs and hypointensity of HCAs on
hepatobiliary phase images are highly accurate discriminators between both
entities. In case of conclusive findings of FNH on gadoxetic-enhanced MRI,
biopsy may be dispensable.
B-0678 11:33
Evaluation of HCC and hypovascular nodules with gadoxetic acid-
enhanced MRI and DWI
C. Briani, M. Di Pietropaolo, G. Federici, M. Marignani, P. Begini, E. Iannicelli;
Rome/IT
Purpose: To investigate the prognostic value of Diffusion Weighted imaging
(DWI) compared to Gadoxetic Acid-enhanced MRI (Gd-EOB-DTPA enhanced
MRI) both in the detection of HCC and hypovascular nodules hypointense on
hepatobiliary phase images (HP), and in the assessment of its evolution.
Methods
and Materials: Fifty-five patients underwent Gd-EOB-DTPA
enhanced MRI including DWI sequences (b-values 50-400-800 s/mm²). We
evaluated nodules size, vascular pattern on dynamic contrast-enhanced MRI
and the signal intensity on HP and on DWI. Statistical differences in the
detection of HCC according to the size were compared by McNemar test.
Fisher's exact test was performed to analyse relationship between size of the
hypovascular nodules and development of the hypervascularisation.
Results
One hundred and five nodules were detected with Gd-EOB-DTPA-
enhanced MRI. Sixty-five/105 nodules showed typical vascular pattern of HCC
on dynamic imaging; 63/65 lesions (96.9%) appeared hypointense on HP,
35/65 HCCs (53.8%) were hyperintense on DWI at b=800 s/mm². Thirty-
nine/105 hypovascular nodules appeared hypointense in the hepatobiliary
phase images. On follow-up MR images 18/39 nodules (46%) showed a typical
vascular pattern of HCC (high risk 10 mm in size p=0.012). Nine/39 (23%)
hypovascular nodules showed hyperintensity on DWI at the first exam, 7 of
these developed into HCC during the follow-up period.
Conclusion
Gd-EOB-enhanced-MRI demonstrated highly accuracy in the
diagnosis of HCC and in the detection of hypovascular nodules with potential
progression to HCC.No significant add value of DWI compared to Gd-EOB-
DTPA enhanced MRI was demonstrated, nevertheless hyperintensity of
hypovascular nodules on high-b-value DWI seems to suggest high risk of
malignant transformation
B-0679 11:42
Hepatocellular carcinoma: correlation between microvascular invasion
with image findings of gadoxetic acid-enhanced MR and [ 18F] FDG uptake
on PET/CT
S. Ahn, J.-M. Lee, I. Joo, E. Lee, J. Han, B. Choi; Seoul/KR
(
[email protected])
Purpose: To analyse the correlation between microvascular invasion (MVI)
with image findings of gadoxetic acid-enhanced MR and [ 18F] FDG uptake on
PET/CT in patients with hepatocellular carcinoma (HCC) who are undergoing
liver transplantation.
Methods
and Materials: 51 patients with 78 HCCs underwent liver
transplantation after MR imaging and [ 18F] FDG-PET/CT. Tumor size, signal
intensity and homogeneity on dynamic phase and hepatobiliary phase (HBP),
tumor margin, peritumoral enhancement, tumor capsule and peritumoral
hypointensity were analysed. To evaluate 18 F-FDG uptake, the SUVmax of
tumor, the ratio of tumor SUVmax to normal-liver SUVmax
(TSUVmax/LSUVmax), and the ratio of tumor SUVmax to normal-liver
SUVmean (TSUVmax/LSUVmean) were analysed. The size, histologic grades,
the presence of MVI of the HCCs were evaluated on pathologic examinations.
Association between the imaging findings with MVI were assessed by Fisher's
exact test and logistic regression analysis. Independent t-test or Mann-Whitney
test were used to compare continuous variables between the positive and
negative MVI groups.
Results
Inhomogeneity on HBP (Odds ratio [OR] = 3.57, p =.032) and
irregular margin (OR = 3.1, p=.035) were predictable factors for MVI.
SUVmax (MVI positive: 5.09 ± 2.39, negative 3.27 ± 1.41, p =.001),
TSUVmax/LSUVmax (positive: 1.59 ±1.53, negative 0.81 ± 0.57, p =.007), and
TSUVmax/LSUVmean (positive: 1.41 ± 1.28, negative 0.77 ± 0.54, p =.008)
were significantly higher in positive MVI groups.
Conclusion
Irregular margin, inhomogenity on HBP of MRI and increased
18 F-FDG uptake on PET are factors that suggest MVI in HCC patients.
B-0680 11:51
Diagnosing MRI and CT in patients with colorectal liver metastases:
diagnostic performance and inter-observer agreement of four different
qualified reviewers
M. Albrecht
1, J.L. Wichmann1, C. Müller1, H. Ackermann1, S. Sakthibalan2,
R. Hammerstingl1, W.O. Bechstein1, T. Schreckenbach1, S. Zangos1,
T.J. Vogl1; 1Frankfurt a. Main/DE, 2London/UK (
[email protected])
Purpose: To compare the diagnostic performance of four different qualified
reviewers retrospectively diagnosing CT and MRI of patients with colorectal
liver metastases (CRLM).
Methods
and Materials: 51 CT and 54 MRI of 105 patients with CRLM prior to
hepatectomy were included. Segments were identified as CRLM positive or
negative using intraoperative findings/histopathology and served as the
Reference
standard for a per-segment analysis. Four reviewers of varied
experience; (A,B,C: radiologists with respectively > 20, > 5, < 1 years of
experience and D: 5
th year medical student) reported the frequency of CRLM
and the segments affected. Per-segment sensitivity, specificity, Cohens Kappa
(5) for diagnosed segments and intra-class correlation coefficients (ICC) for
number of lesions were calculated.
Results
CT sensitivity and specificity was for reviewer A 89.71%/94.41%, B
78.50%/88.37%, C 63.55%/85.58% and D 84.11%/78.60%. MRI sensitivity and
specificity was for reviewer A 90.40%/95.43%, B 74.40%/90.04%, C
60.00%/85.89% and D 65.60%/75.90%. In the analysis of diagnosed segments
(5) and frequency of CRLM per patient (ICC), the overall inter-observer
agreement was higher for CT ( 5=0.43, p < 0.001; ICC=0.75, p < 0.001) than
MRI ( 5=0.38, p < 0.001; ICC= 0.65, p < 0.001). The experienced reviewers A
and B achieved better agreement for MRI ( 5=0.54, p < 0.001; ICC =0.77,
p < 0.001) than CT ( 5=0.52, p < 0.00; ICC=0.76, p < 0.001) unlike the less
experienced (MRI 5=0.38, ICC=0.63 and CT 5=0.41, ICC=0.74, respectively,
p < 0.001).
Conclusion
MRI diagnosis of CRLM should be reserved primarily for expert
radiologists. When compared to experienced radiologists, beginners can
achieve better diagnostic performance with CT than MRI.
10:30 - 12:00 Room F1
Radiographers
SS 1314
Optimisation of imaging examinations
Moderators:
J.-F. Chateil; Bordeaux/FR
F. Zarb; Msida/MT
B-0681 10:30
Ventricular function assessment using MRI: comparative study between
cartesian and radial techniques of k-space filling
C. Ferreira
1, P. Martins2, B. Graça1, F. Peixoto2, S. Monteiro2, S. Barbosa2,
M. Castelo-Branco1; 1Coimbra/PT, 2Aveiro/PT (
[email protected])
Purpose: Radial k-space filling allows an acquisition less prone to movement
artefacts. The aim of this study is to assess overall image quality and compare
cardiac measures derived two k-space sampling techniques (cartesian and
radial) in the evaluation of ventricular function.
Methods
and Materials: Ten healthy volunteers were enrolled in this study.
Cardiac cine images ECG-gated were collected with a cine_SSFP sequence
(standard short-axis orientation), with the two k-space sampling techniques. All
images were qualitatively assessed on a four-point scale (4-excellent, 1-non-
diagnostic). Statistical analysis was performed using Wilcoxon test. The
S283
BA C D E F G
Sunday
differences in the assessment of LV volumes and EF between both k-sampling
techniques were tested using the Student's paired t-test.
Results
Radial technique presented images with fewer artefacts than the
cartesian technique, with overall good delineation of the endocardium. In the
qualitative analysis, radial technique had a median value of 3.00 while the
cartesian had 2.00 (p=0.0315). For quantitative analysis EDV was
137.10±24.29 mL by the radial technique and 132.30 ±24.15 mL by the
cartesian technique (p=0.182). The corresponding EF values were
69.63±4.09% and 68.56±5.17% (p=0.321).
Conclusion
Ventricular function assessment is feasible with the use of radial
k-space sampling with better overall image quality. Radial k-sampling holds
promise in the evaluation of patients with difficulties performing breath-hold
techniques.
B-0682 10:39
Sonoelastography in differentiation of benign and malignant small sized
ovarian tumours
A.E. Khalmukhamedova, V.E. Gazhonova, I.S. Belozerova, A.V. Zubarev;
Moscow/RU (
[email protected])
Purpose: The objective of this study was to evaluate the diagnostic
possibilities of sonoelastography (SE) to differentiate benign from malignant
small sized ovarian tumours.
Methods
and Materials: 86 patients (aged 19-78 years) with ovarian tumours
less than 3 sm were performed conventional TVU on HI VISION Preirus
(Hitachi Medical Corporation). Modified Tsukuba sonoelastography
classification was used for evaluation of the elasticity score of the tumour.
Colour-Doppler and SE data were evaluated independently by two specialists.
US results were compared with surgical and hystomorphological data, MRI,
CT, PET-CT data and abdominal fluid as piration results. Elasticity score
according to the degree and correspondingly distribution of the strain were
established (5 point color scale: 1-3 benign, 4-5 malignant). Strain ratio was
calculated. Inter- and intraobserver variability was calculated.
Results
Based on the data of sonoelastography, 38 hysterectomies, 25
isolated resections of the tumours and 26 ovariectomies were performed. 48
benign and 41 malignant ovarian tumours were revealed by means of final
histopathology. Sonoelastography increased the sensitivity (from 81% to 97%)
and accuracy (from 82% to 94%) of US scanning in diagnostic of ovarian
cancer. Pathomorphological results were compatible to sonoelastography data
in most of the cases (k=0.84, correlation 92%). In 36% cases
sonoelastography increased diagnostic confidence and helped to change the
final diagnosis. The method of sono elastography cannot itself determine the
diagnosis, but in 32% cases it helped differentiating the nature of the tumour.
Conclusion
Real-time sonoelastography is a valuable tool that increases
diagnostic confidence in differentiation small sized ovarian tumours.
B-0683 10:48
Magnetic resonance quantification of iron in basal ganglia using SWI
technique
C.S.P. Rocha, G.A. Preira, M.M.C.P. Ribeiro, P. Sousa, R. Silva; Lisbon/PT
(
[email protected])
Purpose: To verify the effectiveness of magnetic resonance (MR) measuring
the iron concentration in basal ganglia, using susceptibility weighted imaging
(SWI); to optimise intrinsic parameters of SWI sequence, in order to highlight
the evidence of iron and compare those iron concentrations in basal ganglia
among subjects, concerning age, gender and brain hemispheres.
Methods
and Materials: 30 healthy subjects were selected and stratified into
five aged groups, underwent a brain MR by a Magneton Avanto Siemens
TM
(1.5 T) system. Four SWI protocols were applied with different flip angle (FA)
and slice thickness (TH); images were analysed by SPIN TM software, that
allowed the ROIs drawing in phase images. The iron concentrations in
mg/100 g of fresh tissue were measured in six bilateral basal-ganglia.
Results
In males, higher iron concentrations (21.429 ±0.374 mg/100 g) were
found comparing to females (19.883± 0.416 mg/100 g). The same trend was
found in the left hemisphere (18.775 ±4.760 mg/100 g) and throughout
differenced aged groups {[30-40[;[40-50[;[50-60[}; Substantia Nigra, Globus
Pallidus, and Putamen presented higher iron concentrations.
Conclusion
The protocol choice is determinant to assess the iron
concentration with high accurancy. In this study, the best protocol to highlight
the evidence of iron concentration has one with smaller FA and higher TH. Iron
concentration increase according to age increase, male's subjects and left
hemisphere. The robust correlation between results and literature, lead to
assume that iron concentration, measured by SWI, can be used as a
biomarker and can be used by radiographers in the screening and follow-up of
neurodegenerative diseases as Alzheimer, Parkinson and Huntington.
B-0684 10:57
Measurement of bone mass density: comparison of the absorptiometry
(DEXA) and quantitative ultrasonometry methods
R. Patricio, M.C. Ribeiro; Lisbon/PT (
[email protected])
Purpose: Osteoporosis, characterised by loss and hardiness of bone mass,
leads to an increased risk of bone fractures. To use the QUS method, with
reliability, in outpatients or some specific clinical settings such as elderly
homes, continuing care centers, primary care in ambulatory environment, or in
screening programs. This study aim to assess and to compare the values of
bone mass density obtained through the QUS and DEXA methods and to verify
if there is, or not, a constant variation in the obtained values from the same
subject, allowing the establishment of a linear variation pattern.
Methods
and Materials: The sample had 50-86 years old (average=64.16;
SD=12,003). The inclusion criteria were: female, post-menopause, without
bone fractures diagnosed. The bone mass density was evaluated on a set of
32 subjects, using the two methods cons ecutively. To data acquisition were
used an Achilles InSight, System and a Norland both by GE®. Due the
techniques' specificity the QUS was app lied in the calcaneal region and the
DEXA in the lumbar spine.
Results
Using Pearson's correlation tests, were obtained T-score values with
r= 0.556 and Z-score value of r=0.461. The Student's t-test, shown a Z-score
with p=0.005 and for the T-score p=0.466.
Conclusion
It was impossible to establish a trend or a linear variation value,
but there was a positive variation between the T-score values in both methods.
Each method may be applied with reliability but may not be replaced one by
the other, being the QUS method informative and the DEXA diagnostic.
B-0685 11:06
3-point ultrasound for complete diagnosis of deep vein thrombosis of the
lower extremities
A. Latifi
1, F. Labruto2, A. Sundin3, M. Torkzad4; 1Manchester/UK, 2Sydney/AU,
3Stockholm/SE, 4Sollentuna/SE (
[email protected])
Purpose: To investigate the accuracy of 3-point ultrasound for diagnosis of
DVT in patients referred to radiology from the emergency department.
Methods
and Materials: Consecutive and prospective patients referred for
imaging of the lower extremities to rule out primary DVT were asked to enrol in
this study. Three points along the course of the veins were examined in the
following areas: the inguinal area, the popliteal area and the point of maximum
pain if and when identified by the patient's finger The reference tests were
radiologic examinations and follow-up for six months. The radiologic
examination was either complete ultrasound examination of the lower
extremities or ascending venography performed immediately after 3-point
ultrasound by a radiologist blinded to results of 3-point ultrasound.
Results
110 patients have been recruited thus far with complete data and
follow-up. No single case of false negative diagnosis has been detected.
Conclusion
With examination of three points along the course of lower
extremity veins all cases of DVT were detected.
B-0686 11:15
Determining the value of non-traditional approaches to conventional
radiographic imaging of neonates in the post-mortem setting
N.P. Burke1, J. McNulty1, N. Pelletier2, T. Grgurich2, R. Lombardo2,
B. Hennessy2, G. Conlogue2; 1Dublin/IE, 2Hamden, CT/US
(
[email protected])
Purpose: The number of autopsies carried out following sudden infant death
continues to decline, and a stronger reliance on radiological imaging has been
noted in these cases. Despite the growth in the use of cross-sectional imaging
in forensics, conventional radiography continues to play a prominent role in
post-mortem imaging of neonates. This study aims to determine the best
combination of X-ray source, image receptor and kilovoltage peak for use in
the neonatal post-mortem setting where cross-sectional imaging is unavailable.
Methods
and Materials: Rib fractures were simulated on a foetal pig model
and imaged using high and low kVp exposures on CR plates and
mammography film across a Toshiba Kalare X-ray unit, a Siemens Mammomat
300 and a HP Faxitron 43807N cabinet system. A visual grading analysis
(VGA) study was subsequently undertaken to determine which combination
provided the best resolution of the simulated fractures.
Results
Use of mammography film in the cabinet X-ray system with a low kVp
exposure provided the best demonstration of the simulated fracture of interest
[mean image quality score (IQS) of 8.67]. This was closely followed by the
combination of the mammographic unit and digital CR plate---again using a low
kVp exposure (mean IQS of 7.33).
Conclusion
Where cross-sectional imaging is not available or not widely used
in the post-mortem imaging of neonates, it is important to take into account the
alternative approaches of attaining conventional radiographs. The role of the
radiographer in determining the most appropriate approach to imaging such
cases should not be undervalued.
S284
BA C D E F G
Sunday
B-0687 11:24
Is contrast agent necessary for MR angiography?
D. Colson1, C. Cox1, S. Germonpré1, B. Caerts2; 1Brussel/BE, 2Turnhout/BE
(
[email protected])
Purpose: Despite the ongoing evolution of non-contrast-enhanced MRA
techniques, contrast-enhanced MRA is still the standard for accurate diameter
determination of the renal artery. But side effects and especially NSF are not
negligible. Can CE-MRA sequences be replaced by NCE-MRA sequences,
especially for patients with renal problems?
Methods
and Materials: A self-made phantom was used to simulate the renal
artery. The phantom consists of four small tubes made of glass, one without
and three with stenosis (50, 67 and 75%). The data were acquired on an 1.5 T
and 3 T scanner. The CE sequence was performed with a GE sequence with
Gadovist® and the NCE sequence with a PCA sequence. There were also
sequences taken with Dotarem®, but only on the 3 T machine. The images
were evaluated by nine radiologists and nine radiographers.
Results
In the non-stenotic phantom, the results of CE and NCE sequences
were similar. They were both capable of accurate measurement of the
diameter. In the phantoms with stenosis, the PCA sequence overestimated the
stenosis. When the stenosis increased, the overestimation was larger. CE
sequences provided an accurate diameter determination. Only with a severe
stenosis (75%), there was an underestimation. A 1.0 molar contrast agent
yielded superior results to a 0.5 molar contrast agent.
Conclusion
A PCA sequence can replace a CE sequence when there is no
stenosis in the renal artery. When there is a stenosis, a CE sequence can
additionally be performed, especially when there is a severe stenosis.
Preference should be given to a 1.0 molar contrast agent. More research is
necessary for b-SSFP, FSE and ASL.
B-0688 11:33
Parallel MR imaging: technique and significance
M. Kiss, B. Lombay; Miskolc/HU (
[email protected])
Purpose: Parallel Acquisition Technique (PAT) is a special Magnetic
Resonance (MR) imaging tool, which take advantage of the spatial information
and reduce the acquisition time. Parallel imaging become widely available.
There are different types of this technique and radiographers have a crucial
rule to use this technique.
Methods
and Materials: We applied a Siemens Magnetom Symphony 1.5 T,
and a Siemens Magnetom Verio 3 T MR system. We examined 200 patients
and use the PAT in different types of body part e.g. head, spine, abdomen,
angiography, chest and cardiac. For the optimisation of the protocol and image
quality we used different PAT (Grappa, mSense and Caipirinha). We analysed
the image quality, the signal-to-noise ratio (SNR) and the acquisition time.
Some characteristic examples will be presented.
Results
We found significant loss in SNR, and differences between the
various parallel techniquesA few sequences are not good candidates for
parallel imaging - when the SNR was too low. The Grappa technique was the
best method in every type of sequences. The Cipiriniha was useable only the
abdominal imaging. The mSense was much noisier than the Grappa and
Caipirinha in every examinations. We couldn't find significant differences
among the different type of sequences when we applied the PAT.
Conclusion
The parallel imaging have a wide range of clinical applications, it
can be reduce the acquisition time and improved spatial resolution. The
technique is attractive for cardiac-, abdomen and contrast enhancement MR
applications. The main disadvantage to reduce the signal-to-noise ratio.
B-0689 11:42
Implementation of TraumaCad calibration ball in orthopaedic imaging in a
radiology department: a multidisciplinary approach
J. Jensen, B. Mussmann; Odense/DK (
[email protected])
Purpose: TraumaCad® is digital templating software for pre-operative
orthopaedic surgery planning. A correctly placed calibration ball (CB) in the X-
ray is crucial for sizing of orthopae dic implants and visualisation of fracture
reduction. Approximately, 10% of the images need a CB. Positioning of the CB
is time consuming, challenging and may result in retakes. The metallic CB
introduces artifacts possibly obscuring anatomic structures and pathology. The
purpose of this study was to ensure the presence of a CB in all pre-operative
X-rays as opposed to in all x-rays query fracture.
Methods
and Materials: A three-step approach was adopted. 1.
Comprehensive guidelines were developed, introduced and made available at
all X-ray rooms. 2. Multidisciplinary education involving radiographers,
radiologists and orthopaedic surgeons were arranged to gain an
interdisciplinary understanding of the processes involved when placing the CB,
reporting the X-ray and using TraumeCad. 3. Sessions, aimed specifically at
radiographers, on how to identify fractures requiring surgery were held and
repeated. Subsequently audits were performed.
Results
270 consecutive patients were included, of which 24 needed surgery
and 21 of those had a correctly placed CB. 246 patients did not need surgery,
of those 225 were correctly identified as true negative and 21 had a CB in their
X-ray. The sensitivity was 88% and the specificity 91%, with a positive
predictive value of 50% and a negative predictive value of 98%.
Conclusion
The guidelines were successfully introduced and of the included
patients, only three surgery-requiring fractures were missed potentially needing
an additional CB image.
B-0690 11:51
Evaluation of the impact of specific training in the reduction of the
radiography examination errors
A. Santos
1, C. Blanco2, G. Paulo1; 1Coimbra/PT, 2Cuenca/ES
(
[email protected])
Purpose: A radiological protection system shoul d be grounded on justification,
optimisation and limitation, which requi res the implementation of Quality
Assurance Programs. Measure it is difficult with digital systems and as
important changes in their analysis are evident we want to check the way a
specific training programme affects the repet ition rate of conventional digital
radiographic studies.
Methods
and Materials: Data from one month was measured and analysed in
two digital conventional radiology rooms and an observational study, of
prospective nature and fixed cohort, was carried out followed by a training
programme which had an impact on them. Later, an analysis was carried out
again in order to compare and evaluate the results. Thanks to the DICOM
image headers, dosimetric data was analysed and once the relative unit of
value was calculated, the approximate economic saving was estimated.
Results
The rejection rate have decreased 28% thanks to digital systems. It
has been shown that the accountability of the rejection rate lies with the
Radiographer. With training and commitment it is possible to obtain a 31% of
reduction rates. Such a decrease has an impact both on the patient dosage
and related costs.
Conclusion
The rejection rate is a key indicator of the quality of Radiology
facilities and a clear tool which helps avoid unnecessary patient dose. The
Radiographer must bring together and integrate knowledge to avoid repetitions
especially due to erroneous practices. Its application and accountability should
have straight results in dose reduction, contributing to facilitate high quality
health care.
10:30 - 12:00 Room F2
Breast
SS 1302
MRI diffusion: update 2014
Moderators:
C. Dromain; Villejuif/FR
F. Pediconi; Rome/IT
B-0691 10:30
Can quantitative diffusion-weighted imaging (DWI) predict elevated MIB-1
proliferation index in invasive breast cancer?
C. Molinari, V. Bertani, A. Gualano, E. Di Gaetano, R. Girometti, V. Londero,
C. Zuiani, M. Bazzocchi; Udine/IT (
[email protected])
Purpose: To investigate whether quantitative Diffusion-Weighted Imaging
(DWI) parameters predict elevated levels of MIB-1 proliferation index in
patients with breast cancer.
Methods
and Materials: We retrospectively enrolled 52 patients with biopsy-
and surgically-proven invasive cancers (n=52), who underwent preoperative
breast Magnetic Resonance imaging (MRI) on a 1.5 T magnet. MRI
examination included a Single Shot Echoplanar DWI sequence with b values of
0 and 1000s/mm2. For each lesion, two experienced readers in consensus
measured the apparent diffusion coefficient (ADC) (on the ADC maps) and
lesion-to-background-ratio (LBGR) (on b=1000 s/mm2 images). Based on
immunohistochemistry results, we then compared mean ADC and LBGR
values between MIB-1-positive ( > 14%) and MIB-1-negative ( 14%) patients
using the unpaired T-test.
Results
Patients were assessed as MIB-1-positive and MIB-1-negative in
23/52 (44.2%) and 29/52 (55.8%), respectively. ADC values were significantly
(p < 0.05) lower in MIB-1-positive patients (0.86x10-3 s/mm2; 95%IC 0.80 -
0.92) compared to MIB-1-negative ones (1.01x10-3 s/mm2; 95%IC 0.91-1.11).
On the contrary, we showed no significant difference in LBGR between MIB-1-
positive (6.73; 95%IC 4.15-9.32) and MIB-1-negative (9.14; 95%IC 4.45-12.82)
women.
Conclusion
Lower ADC values at DWI are associated with elevated MIB-1
proliferation index in patients with invasive breast cancer.
S285
BA C D E F G
Sunday
B-0692 10:39
Evaluation of apparent diffusion coefficient to predict grade, micro-
invasion and invasion in DCIS
H.M. Hussein, C. Chung, H. Moshonov, M. Naomi, S. Kulkarni, A. Scaranelo;
Toronto, ON/CA (
[email protected])
Purpose: To evaluate the role of apparent diffusion coefficient (ADC) in
distinguishing DCIS grades and identifying micro-invasive/invasive disease.
Methods
and Materials: 71 non-invasive/high-risk core-biopsy proven breast
lesions were assessed preoperatively using diffusion weighted MRI. The ability
of ADC values to distinguish DCIS gra des and predict the presence of invasion
was analysed.
Results
On 3 T, mean ADC value was 1.20 ×103 mm2/s ± 0.48 (SD) (range,
0.47 - 1.78 ×10 3 mm2/s) for non-high grade DCIS, 1.23 x 10-3 mm2/s ± 0.40
(SD) (range, 0.26 - 1.77 ×10 3 mm2/s) for high-grade DCIS, and 1.15 x 10-
3 mm2/s ± 0.45 (SD) (range, 0.26 - 1.75 ×10 3 mm2/s) for
invasive/microinvasive disease. On 1.5 T, mean ADC value was 1.04 x 10-
3 mm2/s ± 0.41 (SD) (range, 0.15 - 1.85 ×10 3 mm2/s) for non-high grade
DCIS, 1.01 x 10-3 mm2/s ± 0.37 (SD) (range, 0.06 - 1.76 ×10 3 mm2/s) for
high-grade DCIS, and 1.11 x 10-3 mm2/s ± 0.30 (SD) (range, 0.64 - 1.76
×103 mm2/s) for invasive/microinvasive disease. Based on logistic regression
analysis, mean ADC value was not a significant predictor for invasiveness
using 1.5 T [OR = 2.6 (95% CI (0.409, 17.12)), p=0.3] or 3 T [OR = 0.4 (95% CI
(0.076, 2.399)), p=0.3]
Conclusion
Mean ADC acquired using a 1.5 T or 3 T MRI was unable to
predict high-grade or invasive disease in biopsy-proven DCIS lesions. Further
work is exploring voxel-based approaches that may better appreciate tumor
heterogeneity and identify sub-regions of tumor with these higher risk features.
B-0693 10:48
Apparent diffusion coefficient measurements of breast tumours at
routine breast magnetic resonance imaging: how reproducible are they?
S.J. Vinnicombe
1, S. Waugh1, Z. Davis2, A.J. Evans1; 1Dundee/UK,
2Edinburgh/UK (
[email protected])
Purpose: Diffusion weighted imaging (DWI) is increasingly utilised for breast
lesion characterisation and assessment of response to chemotherapy, but
there is little data on reproducibility of measurements of the apparent diffusion
coefficient (ADC). The purpose of this work was to analyse intra- and inter-
observer variability of ADC measurements on a series of newly diagnosed
breast malignancies.
Methods
and Materials: IRB approval was waived for this retrospective study
of anonymised data. 46 consecutive patients with biopsy-proven breast cancer
were included. Two experts and one non-expert observer identified index
lesions on DW images (b value 800 or 1,000 s/mm
2) and the corresponding
ADC map. A region of interest was drawn around the lesion manually for
whole-tumour ADC (ADC
WT); for the minimum ADC value (ADC min), a 3 mm 2
ROI was moved over the area of restricted diffusion. Expert observers
repeated the measurements after 1week. Intra and inter-observer variability
was analysed with intraclass correlation coefficients (ICC) and Bland-Altman
plots with calculation of coefficients of repeatability (CoR, all units in mm 2/s).
Results
For masses, reader agreement was high: ADC WT, ICC 0.751, CoR
0.302; ADC min, ICC 0.806, CoR 0.241. For nml, agreement was good for
ADCWT (ICC 0.611, CoR 0.499) but not ADC min (ICC 0.289, CoR 0.578), unless
the inexperienced reader was excluded (CoR 0.079). Intra-reader repeatability
was excellent (ADC WT: ICC > 0.972, CoR 0.976,
CoR< 0.131).
Conclusion
ADC WT measurements are generally highly reproducible for
experts and non-experts. Reproducibility is higher for masses than nml, and for
ADCWT rather than ADC min, where tumour heterogeneity and artefact probably
confound inexperienced readers.
B-0694 10:57
Quantitative analysis of apparent diffusion coefficient maps for breast
cancer diagnosis in 3 T diffusion-weighted MRI
A. Karahaliou
1, K. Vassiou2, S. Skiadopoulos1, N. Arikidis1, I. Fezoulidis2,
L. Costaridou1; 1Patras/GR, 2Larissa/GR (
[email protected])
Purpose: To investigate the feasibility of histogram analysis of ADC maps for
differentiating malignant from benign breas t lesions in 3.0 T diffusion-weighted
MRI (DW-MRI).
Methods
and Materials: Dataset analysed consists of 89 histologically verified
breast lesions (51 malignant, 38 benign) of patients who underwent DW-MRI at
3.0 T (b-values 0, 900 s/mm 2). ADC maps were generated for a slice
representative of lesion largest diameter. An expert radiologist manually
delineated lesion contour on ADC map, defining the lesion region of interest to
be subjected to histogram analysis considering: mean, standard deviation,
skewness, kurtosis, entropy, maximum, minimum and range of ADC values.
The discriminating ability of individual histogram features, as well as of feature
combinations, was investigated employing a least squares minimum distance
classifier. Classification performance was evaluated by means of the area
under receiver operating characteristic curve (Az).
Results
Malignant lesions demonstrated statistically significant lower median
value of ADC feature mean (0.94 x10-3 mm
2/s) and maximum (1.43x10-
3 mm2/s), as compared to benign lesions (mean: 1.49x10-3 mm 2/s and
maximum: 1.94x10-3 mm 2/s). Malignant lesions demonstrated increased
entropy (5.82) reflecting increased ADC heterogeneity, as compared to benign
ones (5.62). Among individual features, best classification was achieved by
ADC feature mean (Az=0.87 ±0.04). The feature subset comprising of ADC
mean, entropy and minimum demonstrated the highest classification
performance (0.91±0.03).
Conclusion
Histogram analysis of ADC maps allows for quantification of
specific lesion ADC heterogeneity properties, improving the potential of DW-
MRI in differentiating malignant from benign breast lesions.
B-0695 11:06
BI-RADS 4 lesions only visible on contrast-enhanced MRI: can apparent
diffusion coefficient measurements differentiate benign from malignant?
P.A.T. Baltzer, K. Pinker-Domenig, M. Bernathova, T.H. Helbich; Vienna/AT
(
[email protected])
Purpose: Due to its high sensitivity, contrast-enhanced breast MRI detects
suspicious lesions otherwise not visible. Here, MRI-guided biopsy is applied.
Unnecessary biopsies in benign lesions cause costs and patient inconvenience
and should thus be avoided. This study investigates the use of apparent
diffusion coefficient (ADC) in lesions only visible on MRI.
Methods
and Materials: A retrospective review of our single-center
prospectively populated database revealed 101 patients (mean age 49.5, SD
13.9, median 48, IQR 17 years) who underwent diffusion-weighted imaging at
1.5 T. The patients showed 104 lesions visible on MRI only classified as BI-
RADS 4 based on BI-RADS criteria and were scheduled for MRI-guided
biopsy. ADC values were measured by an experienced radiologist blinded to
histopathologic results. Diagnostic accuracy was investigated using ROC
analysis.
Results
Histopathology revealed 20 malignant and 84 benign lesions. Lesions
were classified as mass in 61 (15 malignant, 24.6%) and non-mass in 43 (5
malignant, 11.6%). At an ADC cut-off level of 1.258*10
-3 mm2/s, ROC
analysis showed a sensitivity and specificity for ADC measurements of 80%
and 79.8%, respectively. In mass lesions, sensitivity and specificity were
93.3% and 82.6%. In non-mass lesions, lower sensitivity (80%) and specificity
(65.8%) were observed.
Conclusion
ADC measurements can help to differentiate breast lesions only
visible on MRI and classified as BI-RADS 4 by BI-RADS criteria. Higher
sensitivity and specificity are observed in mass lesions as compared to non-
mass lesions was observed.
B-0696 11:15
Improving the accuracy of breast MRI: could diffusion-weighted imaging
(DWI) overcome background parenchymal enhancement (BPE)?
M. Panzeri, C. Losio, G. Cristel, M. Rodighiero, S. Tacchini, F. De Cobelli,
A. Del Maschio; Milan/IT
Purpose: BPE can limit the accuracy of breast-MRI similarly to what occurs in
mammographically dense breast, requiring a short-term, expensive MRI-
follow-up. We evaluated if the adjunct of DWI could help in this difficult setting.
Methods
and Materials: Out of 1757 MRI examinations performed from 2008
to 2013, 338 (19%) were reported of limited diagnostic value due to BPE; 84
including DWI and a minimum 1-year follow-up were considered. Four classes
were defined according to their BPE patterns: 40% (34/84) of women had
minimal BPE, 38% (32/84) mild BPE, 14% (12/84) moderate and 7% (6/84)
marked. MRI alone and MRI+DWI were compared regarding diagnostic
performance, BI-RADS, biopsy rate, histopathology/follow-up. Agreement with
histopathology was assessed by the estimate of the Cohen's K statistic.
Results
A higher number of BI-RADS 1-2 was found in patients with minimal
BPE than in those with mild to marked (p=0.001). Out of 31 suspicious
enhancements, 47% were confirmed as malignant (7 IDC, 3 ILC, 3 tubular and
1 papillary carcinoma, 2 DCIS, 2 sarcoma). There was no significant difference
in biopsy rate among various BPE patterns . The sensitivity, specificity, positive
and negative predictive values were, respectively, 89%, 87%, 53% and 98%
for MRI alone, 93%, 84%, 70% and 97% for MRI+DWI. Agreement with
histopathology was improved by DWI (k=0.71 vs. k=0.59).
Conclusion
Compared to conventional breast-MRI, DWI significantly
improves the positive predictive value in case of BPE. However, since DWI
does not increase the negative predictive value, all BPEs with negative DWI
should undergo a short-term follow-up.
S286
BA C D E F G
Sunday
B-0697 11:24
Can diffusion-weighted magnetic resonance imaging differentiate
between metastatic and non-metastatic axillary lymph nodes in patients
with breast cancer?
F. Fornasa, S. Nencioni, A. Dibenedetto; S. Bonifacio/IT
(
[email protected])
Purpose: To assess the accuracy of Diffusion-weighted Magnetic Resonance
Imaging (DWI) in differentiating between metastatic and normal axillary lymph
nodes in patients with breast cancer.
Methods
and Materials: 250 patients with histolog ically proven breast cancer
underwent breast MRI (1.5 T; 4-channel coil) within two weeks prior to axillary
dissection. The axilla ipsilateral to the tu mor was included into the field of view;
if a lymph node was detected with morphological features (short axis = 7 mm
or more) deeming malignancy likely, DWI (b values: 0 and 800 mm/sec2) was
performed and a lymph nodal Apparent Diffusion Coefficient (ADC) was
obtained through the average of three different measurements. Patients were
included if histology after axillary dissection demonstrated, in the lymph node
evaluated with DWI, either a metastasis larger than 5 mm or the absence of
metastases. 43 patients (age range: 38-79 years) meeting the above
mentioned criteria were included in this study. The Student's t-test was used.
Results
At histology 19 patients had one lymph node with a metastasis larger
than 5 mm and 24 had not. The ADC values of the metastatic lymph nodes
(mean: 0.878 mm2/sec; range: 0.30-1.20) were significantly lower (p < 0.001)
than those of the metastasis-free lymph nodes (mean: 1.494; range: 0.60-
2.50). With a cutoff value of 1.09 mm2/sec (two false positive; one false
negative result) DWI proved 94.7% sensitive, 91.7% specific and 93.0%
accurate in the diagnosis of lymph node metastasis.
Conclusion
DWI is able in differentiating between metastatic and metastasis-
free axillary lymph nodes in breast cancer.
B-0698 11:33
Diffusion-weighted imaging of breast lesions: a systematic review and
meta-analysis
M.D. Dorrius, H. Dijkstra, M. Oudkerk, P.E. Sijens; Groningen/NL
(
[email protected])
Purpose: To evaluate the effect of the choice of b-values and prior use of
contrast medium on ADCs of breast lesions derived from DWI, and on the
discrimination between benign and malignant lesions.
Methods
and Materials: A literature search was performed of relevant DWI
studies. Meta-analysis focussed on ADC-values rather than true diffusion, not
available in the fast majority of studies acquired with just a few b-values. The
accuracy of DWI to characterise lesions by using b-value 600s/mm
2 and b-
value > 600s/mm2 was presented as pooled sensitivity and specificity. The
ADC was calculated for both groups. This choice of cut-off was motivated by
earlier findings in a breast DWI study of healthy volunteers, demonstrating that
at b-values smaller than 600s/mm
2 the DW signal is monoexponential. Also,
lesions were pooled as pre- or post-contrast DWI.
Results
Of 317 articles, 26 met the inclusion criteria. Mean ADC was
significantly higher (p 600s/mm2. The sensitivity (91% and 89%, respectively) and specificity
(75% and 84%) were similar (p > 0.05) in both groups. Contrast media had no
significant effects on the ADCs (p> 0.08). The contrast between benign and
malignant lesions was optimal (58.4%) for the combination of b=0 and
1000s/mm2.
Conclusion
The wide variety of b-value combinations applied in different
studies significantly affects the ADC of breast lesions and therefore confounds
quantitative DWI. If only a couple of b-values are used, those of b=0 and
1000s/mm
2 are recommended for the best improvement of contrast between
benign and malignant lesions.
B-0699 11:42
Quantitative diffusion-weighted imaging at 3 T for the detection of breast
cancer: influence of ROI-selection on the diagnostic performance
H. Bickel, K. Pinker-Domenig, P.A.T. Baltzer, T.H. Helbich; Vienna/AT
(
[email protected])
Purpose: Diffusion-weighted imaging (DWI), using apparent diffusion
coefficient (ADC), is a powerful tool for the diagnosis of breast cancer.
However, no consensus on which is the best way to measure ADC exists.
Thus, the aim of this study was to compare different approaches on region of
interest (ROI) selection and their influence on diagnostic performance.
Methods
and Materials: 3 T MRI-scans of 102 patients with breast lesions
(BI-RADS 3-5) were evaluated by a blinded reader. T2-w, contrast-enhanced
T1-w and DWI sequences were used for lesion identification. Manually drawn
ROIs were placed on the ADC maps: a two-dimensional (2D) ROI inside the
lesion part with the lowest ADC values and a three-dimensional (3D) ROI
covering the whole lesion. Minimum, maximum and mean ADC was measured.
All lesions were histopathologically ve rified. Means were compared between
benign and malignant lesions and between the different measurement
approaches. ROC-curves were drawn to compare diagnostic performance.
Results
Mean ADC was significantly different between benign (n=20) and
malignant (n=82) lesions for both 3D and 2D ROIs in all measurements
(p <.001). ROC curves showed comparable results (AUC between.97 and.993)
for all approaches except maximum ADC of the whole lesion (AUC.794).
Maximum ADC in the region of the lowest ADC was best for differentiation of
benign and malignant lesions.
Conclusion
All measurement approaches except maximum ADC of the whole
lesion performed excellently and are feasible for the differentiation of benign
and malignant breast lesions.
Author Disclosures:
T.H. Helbich: Consultant; Siemens AG, Hologic Inc. Grant Recipient; Siemens
AG.
B-0700 11:51
Quantitative diffusion-weighted imaging (DWI) of additional lesions at
pre-operative breast MRI: a practical tool to prevent overtreatment?
M. Panzeri, C. Losio, R. Cavallin, E. Venturini, G. Cristel, S. Tacchini,
M. Rodighiero, F. De Cobelli, A. Del Maschio; Milan/IT
(
[email protected])
Purpose: To assess the impact of DWI on the surgical management of
additional lesions depicted at pre-operative MRI.
Methods
and Materials: Out of 150 patients undergoing breast MRI for
locoregional staging between 2008 and 2013, 50 directly underwent surgery.
MRI examinations were classified based up on additional lesions features and
location: no impact if no additional lesion was identified or if the additional
lesion (s) didn't change surgery; good impact if additional malignant lesions
were correctly identified (extended surgery); bad impact when an additional
suspicious lesion was not confirmed at fi nal histopatology (incorrect extended
surgery). Additional lesions were classi fied according to their morpho-kinetic
features and DWI signal (BI-RADS).
Results
Of the 46 additional findings seen on MRI, 35 required a wider
surgery. In 29% (10/35) of these, malignancy was not confirmed at final
histopathology. The Apparent Diffusion Coefficient (ADC) measured with DWI
would have correctly diagnosed all the 25 additional malignancies, modifying
the multifocal/multicentric status. Dynamic-MRI alone had no impact on 31
patients (64%), good impact on 11 patients (22%) and bad impact on 8
patients (14%). The addition of ADC to dynamic-MRI would have lead to no
impact on 35 patients (70%), good impact on 14 patients (28%) and bad
impact on 1 patient (2%).
Conclusion
Quantitative DWI improves the performance of pre-operative
Breast MRI in the characterisation of additional lesions, allowing a more
confident definition of multicentric and mu ltifocal disease. This feature can be
helpful in reducing the number of pre-surgical biopsies and unnecessary
extended surgery induced by Breast-MRI.
S287
BA C D E F G
Sunday
10:30 - 12:00 Room G/H
Genitourinary
SS 1307
Renal tumours: diagnosis and intervention
Moderators:
T.M. Cunha; Lisbon/PT
R.S. Lanzman; Düsseldorf/DE
B-0701 10:30
Multiparametric magnetic resonance imaging to differentiate common
subtypes of renal tumours
E. Tricaud, F. Cornelis, N. Grenier; Bordeaux/FR (
[email protected])
Purpose: To retrospectively evaluate the ability of magnetic resonance (MR)
imaging to differentiate common types of renal tumours using parameters
derived from routinely performed sequences.
Methods
and Materials: MR images from 100 pathologically proven solid
renal tumours without macroscopic fat (57 clear-cell, 16 papillary, 7
chromophobe renal cell carcinomas (RCCs), 16 oncocytomas and 4 minimal
fat angiomyolipomas (AMLs)) treated at a single institution between 2009 and
2012 were evaluated. Two radiologists blinded to pathology results reviewed
independently double-echo chemical shift, T1- and T2-weighted images, and
ADC maps. Signal intensity index (SII), tumour-to-spleen SI ratio (TSR), ADC
ratio, wash-in (WiI) and wash-out indices (WoI) between different phases
(arterial, parenchymal or late) were calculated. Results were analysed with
Wilcoxon sum rank, Fisher's exact tests and receiver operating characteristics,
and diagnostic accuracy estimated. A Bonferroni correction was applied to
correct for multiple testing.
Results
There were significant differences between papillary RCCs and other
renal tumours for arterial WiI (P < 0.001, area under the curve (AUC)=0.92),
initial WoI (P=0.006, AUC=0.72) and ADC ratio (P < 0.001, AUC=0.85);
between chromophobe RCCs and oncocytomas for TSR (P=0.02, AUC=0.8),
parenchymal WiI (P=0.03, AUC=0.74), late WiI (P=0.02, AUC=0.77), initial WoI
(P=0.03, AUC=0.8) and late WoI (P=0.04, AUC=0.79); and between clear-cell
RCCs and oncocytomas for SII (P=0.01, AUC=0.71) and parenchymal WiI
(P=0.01, AUC=0.69). Multiparametric analysis distinguished papillary RCCs
from other renal tumours (sensitivity: 37.5%, specificity: 100%) and
oncocytomas from chromophobe and clear-cell RCCs (sensitivity, specificity:
25%, 100% and 18.7%, 94.2%, respectively).
Conclusion
Multiparametric MR imaging seems useful before deciding the
most appropriate therapeutic management.
B-0702 10:39
Contribution of ADC value to histopathological differentiation of renal
tumors
J. Lisý, M. Chocholatý, K. Havlová, L. Mik ík, H. B ezinová, M. Schmidt;
Prague/CZ (
[email protected])
Purpose: To evaluate ability of the apparent diffusion coefficient (ADC) value
in differentiation of histological types of renal tumors.
Methods
and Materials: MRI examination including DWI with b coefficients 0,
400, 1000 was performed in 82 patients with renal tumor before surgery. Mean
ADC values in tumor lesion were correlated with histopathological finding after
surgery. Histopathological typing proved 61 cases of clear cell carcinoma
(ccRCC), 8 papillary RCCs, 2 chromophobe RCCs, 5 oncocytomas, 3
angiomyolipomas, 2 urethelial carcinomas and 1 papillary adenoma. Results
were statistically correlated by t-test.
Results
Mean ADC value in different renal tumors was: ccRCC 1.51 x 10
-
3 mm2/s, papillary RCC 0.855 x 10 -3 mm2/s, chromophobe RCC 0.82 x 10 -
3 mm2/s, oncocytoma 1,351 x 10 -3 mm2/s, angiomyolipoma 1.72 x 10 -3 mm2/s,
urothelial carcinoma 1.1 x 10 -3 mm2/s, papillary adenoma 1,445 x 10 -3 mm2/s.
Correlation between different histopathological types of renal tumors and mean
ADC value was found (p < 0.05). Correlation between histological grading and
mean ADC value in ccRCC was statistically significant (p < 0.03).
Conclusion
Mean ADC value is helpful in histopathological differentiation of
renal tumors.
B-0703 10:48
Small clear cell renal carcinoma: correlation between CT findings and
histologic grade
S. Choi, D. Sung, S. Oh, N. Han, B. Park, M. Kim, S. Cho; Seoul/KR
(
[email protected])
Purpose: To evaluate the correlation between CT findings and histologic
grade (Fuhrman grade) of small clear cell renal cell carcinoma (CCRCC),
which is significant prognostic factor.
Methods
and Materials: We retrospectively reviewed 88 pathologically proven
small ( 4 cm, pT1a), CCRCCs in 87 patients. Two radiologists independently
analysed tumour shape, margin, encapsulation, enhancement pattern and
relative enhancement to renal cortex on CT scan. Enhancement patterns were
defined according to the percentage of diffuse enhancement (pattern 1,
homogeneous 90%; pattern 2, relative homogeneous 75-90%; pattern 3,
heterogeneous < 75%). Histologic grade was divided into two groups: low
(Fuhrman grade 1 or 2) and high (3 or 4).
Results
Sixty low-grade (68.2%) and twenty-eight high-grade (31.8%) small
CCRCCs were assessed. We found a statistically significant correlation
between enhancement pattern and the Furhman grade with good interobserver
agreement. The lower grade RCCs tend to be more homogeneous
enhancement (p < 0.001 and p=0.003, reader 1 and reader 2, 5=0.688).
Hyperattenuating tumour than adjacent normal renal cortex was exclusively
founded in the low-grade group (p=0.024 for both readers, 5=0.635). The
prevalence of ovoid shape, indistinct ma rgin and absence of encapsulation in
low-grade RCCs were significantly greater than in high-grade group for reader
1, but no significant difference was found for reader 2 (p=0.003, p=0.028,
p < 0.001, respectively for reader 1; p=0.895, p=0.680, p=0.674, respectively,
for reader 2).
Conclusion
Homogeneous tumoural enhancement and hyperattenuating
tumour at contrast-enhanced CT were related to low-Fuhrman grade of small
CCRCCs. These data may have implications for active surveillance of small
CCRCCs.
B-0704 10:57
The use of contrast-enhanced ultrasonography (CEUS) in classification
of renal cystic lesions
J. Foukal, M. Mechl; Brno/CZ (
[email protected])
Purpose: To evaluate the classification of cystic renal lesions with CEUS and
to compare the results with CT.
Methods
and Materials: The set consists of 112 lesion in 94 patients who had
CT and CEUS with renal lesion that was cystic on at least one of the methods.
Lesions were evaluated by Bosniak classifi cation and either histologically
verified or followed-up for at least 2 years. We assessed correlation between
methods, sensitivity and specificity for malignancy detection from the viewpoint
of Bosniak classification, sensitivity for det ection of individual features used in
Bosniak classification and odds ratios of malignancy for this features. Data
were processed by ROC analysis. Stati stical significance was assessed by
Fisher's exact test.
Results
Overall agreement between methods was 61%, with division to non-
surgical (category I, II, IIF) and surgical (III, IV, solid) groups agreement was
90%. With this division sensitivity, s pecificity, PPV and NPV was 92.3%,
90.9%, 57.1%, 98.9% for CEUS and 69.2%, 94.9%, 64.3%, 95.9% for CT.
CEUS was more sensitive than CT in detecting septa (53% vs. 25% of lesions,
p < 0.001) and in detecting enhancement of septa (22% vs. 10% of lesions,
p < 0.001). Solid component enhancement was not significantly different, but
on CEUS this was more predictive factor for malignancy detection (increased
likelihood of malignancy 384 times on CEUS, 78 times on CT, p < 0.001).
Conclusion
Results of CEUS correlate with CT. Sensitivity of CEUS for the
detection of malignancy was higher than that of CT, specificity was slightly
lower.
B-0705 11:06
The accuracy and interobserver variability of multidetector computer
tomography (MDCT) for T staging of renal cell carcinoma
A. Lebovici
1, M. Buruian2, D.S. Feier1, A. Tamas-Szora1, M.D. Suciu1,
S.A. Sfrangeu1; 1Cluj-Napoca/RO, 2Targu-Mures/RO
(
[email protected])
Purpose: To determine the accuracy and interobserver variability of
multidetector computer tomography (MDCT) for T staging of patients with renal
cell carcinoma.
Methods
and Materials: Two young readers, with three and six years of
experience in genitourinary imaging, independently and in consensus reviewed
the imaging and histology data of 113 patients (84 males, mean age 57.4 ±12
years) with RCC (91-clear-cell, 15-chromophobe, 4-papillary, 2-collector duct,
1-translocation). Patients underwent multiphase contrast enhanced 64-MDCT
and partial or radical nephrectomy. Pathological analysis revealed 54 (47.8%)
T1 lesions (25-T1a, 29-T1b), 10 (8.8%) T2 lesions (6-2a, 4-2b), 45 (39.9%) T3
lesions (34-3a, 11-T3b) and 4 (3.5%) T4 lesions. The accuracy of MDCT in T
staging of RCC was assessed using receiver operating curve (ROC) analysis.
Interobserver variability was assessed using inter-rater agreement statistics
(Kappa).
Results
In consensus, MDCT performed best in predicting RCC stage T1
(AUROC=0.87, Se=92.6%, Sp=81.4%) and stage T4 (AUROC=0.87, Se=75%,
Sp=100%). The AUROC for stage T2 was 0.71 (Se=50%, Sp=93.2%) and for
stage T3 was 0.78 (Se=66.7%, Sp=89.7%). Independently, the more
experienced reader performed better in T staging of RCC, in good agreement
S288
BA C D E F G
Sunday
with the histology results (kappa=0.78), correctly classifying 50 patients with T1
(92%), 5 patients with T2 (50%), 30 patients with T3 (66%) and 3 patients with
T4 (75%). The interobserver agreement was fairly good (kappa=0.61).
Conclusion
MDCT performs best in predicting early (stage T1) and advanced
RCC (stage T4), with fairly good interobserver variability.
B-0706 11:15
Novel anatomic kidney segmentation in nephron sparing surgery: a
comprehensive CT-scan based reporting
P. Lodise, V. Panebianco, A. Cannavale, F. Barchetti, V. Forte, C. Catalano;
Rome/IT (
[email protected])
Purpose: Introduce a novel a segmental anatomy of the kidney with a
standardised radiological reporting method to describe renal masses ( < 7 cm)
location and pathological features.
Methods
and Materials: 63 patients underwent multiphase MDCT scan with
1 mm acquisitions. We divided the kidney into 3 zones and 12 segments. 2
radiologists blindly read all cases according to a standardised report method:
tumour size, location in kidney's segments, exophityc growth, collecting
system's relationship and tumour's feeding arteries (FA). Intra and inter-
observer reliability was assessed with k-statistic test.
Results
63 tumours were diagnosed. 10 (15.8%) were mono-segmental, 23
(36.5%) involved 2 segments, 18 (28.5%) involved 3 segments, and 12
tumours (19%) involved 4 segments. Mean exophytic percentage of the lesions
was 24.9%: 8.6 % of the tumours were > 2/3 exophytic, in 40 % of the tumours
the exophytic growth pattern was comprised between 1/3 and 2/3, 36.1% were
< 1/3 exophytic and 15.2 % were completely endophytic. Dislocation and
infiltration of the collecting system was observed in 21 (28.5%) and 16 (25.4%)
tumours, respectively. In the remaining 26 tumours, mean distance from the
collecting system was 7.7 mm. In 39 tumours, one FA was detected; in 15
tumours, two FAs were detected and in 9 tumours 3 or 4 FAs were detected.
Intra and inter-observer reliability resulted as k=0.95 and 0.91, respectively.
Mean reporting time was 16±4 mins.
Conclusion
Kidney segmentation and standardised radiological report are an
exhaustive manner to describe small renal masses location and provide
information for clinical practice.
B-0707 11:24
Early antiangiogenic effects of multikinase inhibitors in patients with
metastatic renal cell cancer using dynamic contrast enhanced CT: initial
Results
of a pilot study
A. Sterzik, M. Staehler, J. Casuscelli, M. Karpitschka, F. Schwarz, M.F. Reiser,
A. Graser; Munich/DE (
[email protected])
Purpose: To correlate early changes of tumor perfusion assessed by DCE-CT
in mRCC patients under MKI with available preliminary data of clinical
response.
Methods
and Materials: 40 patients (29 males, 11 females, 68 ±7 years) with
mRCC underwent perfusion CT imaging of representative metastatic lesions
on a dual-source CT scanner (10 cm z-axis coverage, acquisition time 43 sec,
100 kVp (abdomen), 80 kVp (chest), 100 mAs). Two subsequent DCE-scans
were performed before and 7 days after start of treatment with Sunitib (n=30)
or Pazopanib (n=10). Blood flow (BF), blood volume (BV) and permeability-
surface area product (PS) were calculated for the entire tumor volume. Results
were correlated to RECIST-based response and progression-free interval
(PFI).
Results
Comparing baseline and follow-up scan, perfusion CT showed a
profound reduction of mean BF, BV and PS 7 days after therapy initiation
(range -44% to -31%; all p-values < 0.001). Responders (n=15) - defined by
their best overall response according to RECIST - showed a significantly
greater reduction of mean BF and BV-values on day 7 than Non-Responders
(= patients with stable/progressive disease, n=25): -53% ±26% vs. -32% ±28%
for BF and -51% ±20% vs. -33% ±25% for BV, all p-values 7 months (n=24) was more pronounced than
in patients with a PFI < 7 months (-57% ±29% vs. -32% ±23%; p=0.029). PS-
perfusion indices were not found predictive for therapy response.
Conclusion
Early changes in DCE-parameters of tumor perfusion in patients
with mRCC under MKI might yield the potential to predict biologic response to
antiangiogenic drugs.
Author Disclosures:
A. Sterzik: Grant Recipient; Bayer Healthcare. M. Staehler: Consultant;
Novartis, Pfizer. Speaker; Novartis, Pfizer. A. Graser: Consultant; Siemens
Healthcare, Bayer Healthcare. Speaker; Bayer Healthcare, Siemens
Healthcare.
B-0708 11:33
Beyond RECIST criteria: the role of MR perfusion in evaluating response
to anti-angiogenic therapy in patients with metastatic renal cancer
M.G. Bernieri, F. Barchetti, V. Forte, E.L. Indino, C. Catalano, V. Panebianco;
Rome/IT (
[email protected])
Purpose: To determine the role of MRI perfusion technique for evaluating
response to anti-angiogenic therapy in patients with metastatic renal cell
carcinoma (RCC) using as criteria the dimensional changes and the
vascularisation degree.
Methods
and Materials: 46 patients (108 lesions) with primitive and/or
metastatic RCC were evaluated with MRI before and during anti-angiogenic
therapy (at 0, 4, 8 weeks); we assessed the lesion changes of dimension
according to RECIST guidelines and vascularisation degree through perfusion
volume (VP) evaluation; to obtain this parameter, we used a T1-weighted GRE
sequence acquired after intravenous administration of contrast medium and an
editing software (Functool 7.4).
Results
After 4 weeks, we observed a response to therapy (complete or
partial: CR/PR) in 67.7% of lesions considering the size criteria and 77.6%
according to VP; stable disease (SD) in 6.5% considering RECIST and 3%
according to VP; progression of disease in 25.8% according to RECIST and in
19.4% considering VP. After 8 weeks, we reached a CR/PR in 74% of the
lesions taking into account RECIST and in 80% considering VP, SD in 6%
according to RECIST and in 0% taking into account VP, PD in 20% of the
lesion considering both methods of analysis (RECIST and VP).
Conclusion
Functional MRI is a valid method for evaluating neoangiogenesis
in primary and/or metastatic RCC; considering VP rather than dimensional
changes allows to assess early anti-angiogenic therapy effectiveness to
determine a proper use.
B-0709 11:42
Radiofrequency ablation of sporadic cystic renal masses: mid-term
outcomes
H. Kim, M. Cha, B. Park, J. Park, S. Park, C. Kim; Seoul/KR
(
[email protected])
Purpose: To retrospectively investigate the mid-term outcomes of
radiofrequency ablation (RFA) for sporadic Bosniak III or IV masses.
Methods
and Materials: Between May 2003 and May 2013, 27 patients
(mean, 55 years; range, 22 - 77 years) with 27 sporadic cystic renal masses
(mean, 2.8 ± 0.2 cm; range, 1.1 - 4.8 cm) underwent percutaneous RFA and
follow-up CT or MRI was performed for 6 months or longer (mean, 23.4 ± 3.5
months; range, 6 - 65 months). Renal masses consisted of 18 Bosniak III and 9
Bosniak IV lesions. The mean ablation duration, number of session, technical
success rate, primary and second effectiveness rates, cancer-specific and
overall survival rates, complications, and estimated glomerular filtration rate
(eGFR) were analysed. The Kaplan-Meier survival curve and Wilcoxon Signed-
rank test were used for the statistical analysis.
Results
The mean ablation duration and number of session were
20.5 ± 18.7 min (range, 5 - 78 min) and 1.1 ± 0.3 (range, 1 - 2), respectively.
The technical success rate was 100% (27/27). The primary and secondary
effectiveness rates were 88.9% (24/27) and 100% (3/3), respectively. The 2-
year cancer-specific and overall survival rates were 100% and 95.5%,
respectively. The major and minor complication rates were 3.7% (1/27) and
25.9% (7/27), respectively. The median eGFR had decreased slightly 1 - 6
months after the RFA (pre-RFA, 80.5 mL/min/1.73 m
2; post-RFA,
74.8 mL/min/1.73 m2; p < 0.001).
Conclusion
RFA has potential to effectively treat sporadic Bosniak III or IV
masses in poor surgical candidates.
B-0710 11:51
Modified renal score: quantitative criteria predicting the complexity of
radiofrequency ablation of renal tumours
R. Betari, A. Mejean, C. Elie, M.-O. Timsit, S. Richard, V. Delmas, O. Helenon,
J.-M. Correas; Paris/FR
Purpose: To develop and test a predictive score for complications (including
therapeutic failure) of radiofrequency ablation (RFA) of renal tumours.
Methods
and Materials: 442 consecutive RFA procedures were
retrospectively evaluated between 2005 and 2012. We collected and analysed
each of the following data on imaging regarding the tumour to determine their
clinical relevance separately and as a score: depth, diameter, size of the
endophytic portion, distance between the tumour and the closest critical
anatomical structure, distance between the tumour and a perpendicular line to
the renal sinus, distance between the tumour and the digestive tract or the
diaphragm, tumour enhancement. We defined two groups using the Clavien-
Dindo scoring system (CD) and the therapeutic outcome of the procedure
(CD< 2 and success vs. CD 2 or failure). Data were analysed using the
Student t test and Wilcoxon test.
S289
BA C D E F G
Sunday
Results
Five criteria were useful to predict the complexity of a procedure.
Depth (p=6.55.10e-5), diameter (p=2.79.10e-8), endophytic extension
(p=6.01.10e-9), distance to the closest critical anatomical structure
(p=1.21.10e-9), distance to the digestive tract (p=0.029). Thresholds were
found for the first three criteria (respectively 85, 26, 20 mm). There was no
statistically significant difference between the two groups for the other criteria.
Conclusion
A new predictive score using relevant criteria can be proposed to
assess a renal tumour before a RFA. Complications or therapeutic failure is
less likely to happen after a procedure if the tumour is less than 26 mm,
superficial, mainly exophytic, distant to the digestive tract, located far from a
critical organ.
10:30 - 12:00 Room I/K
Neuro
SS 1311
Endovascular treatment
Moderators:
A. Dörfler; Erlangen/DE
I.Q. Grunwald; Oxford/UK
B-0711 10:30
Thrombus-length pedicts outcome in patients with cerebral artery
occlusion treated with intravenous fibrinolysis
C. Ovesen, K. Hansson-Lundblad, I. Havsteen, C.R. Trampedach,
C. Musaeus, H. Christensen, A. Christensen; Copenhagen/DK
(
[email protected])
Purpose: The length of a cerebral artery occlusion has been suggested to
affect the efficacy of intravenous fibrinolysis in facilitating reperfusion. We
investigated the association between thrombus-length and short- and long-
term outcome.
Methods
and Materials: We included patients admitted within 4.5 hours after
onset of stroke and a computed tomography angiography (CTA) demonstrated
middle cerebral artery occlusion. All patients had intravenous tissue
plasminogen activator as only reperfusion therapy. Thrombus-length was
measured on CTA. Short-term outcome was measured as difference between
National Institute of Health Stroke Scale on admission and day-2 ( ,NIHSS).
Long-term outcome was measured as 90-days modified Rankin Scale (mRS).
Results
We included 70 patients. Mean (SD) thrombus-length was 22.0 mm
(10.0 mm). The median (IQR) NIHSS on admission was 14 (9-18) and 9 (3.5-
16) on day 2; 90-days median (IQR) mRS was 3 (1-5). There was a good
correlation between admission NIHSS and thrombus-length (r
s = 0.312; p =
0.009) as well as 90-day mRS and thrombus-length (r s = 0.262; p = 0.034). No
correlation was observed between ,NIHSS and thrombus-length (r s= -0.139; p
= 0.255). Increasing thrombus-length was a univariate predictor of good (mRS
0-3) and poor (mRS 5-6) outcome (OR 0.94 CI: 0.90-0.99 and OR 1.17 CI:
1.01-1.14 per mm increase, respectively). When adjusting for NIHSS and age,
the effect of thrombus-length on good outcome was removed however the
effect on poor outcome remained (OR 1.09 CI: 1.01-1.16 pr. mm)
Conclusion
Thrombus-length covariates with stroke severity and predicts
poor outcome. Thrombus-length is not associated with early remission after
fibrinolysis.
B-0712 10:39
MR angiographic and clinical long-term follow-up after intracranial
mechanical thrombectomy using solitaire FR device
F. Eugene1, H. Raoult1, J. Gentric2, G. Mineur1, B. Carsin1, T. Ronziere1,
A. Stamm1, J. Ferre1, J. Gauvrit1; 1Rennes/FR, 2Brest/FR
(
[email protected])
Purpose: Little is known about consequences of arterial wall damages
possibly due to mechanical endovascular thrombectomy (MET). Our aim was
to perform angiographic and clinical long-term follow-up (FU) of patients
treated with MET using Solitaire FR.
Methods
and Materials: Forty-five stroke patients treated during August 2010
to February 2012 were prospectively evaluated. Angiographic imaging was
performed on a 3 T MRI and included intracranial arteries TOF-MR
angiography (MRA) and supra-aortic arteries gadolinium-enhanced MRA.
Images were assessed to detect arterial anomalies (stenosis, occlusions, and
dilatation) in comparison post-MET final run.Clinical evaluation was performed
with the modified Rankin Scale score (mRS), compared with 3-month mRS,
and the quality of life SF-36 scale.
Results
Thirty-four patients were assessed at the mean term of 449 days
(median 451; range 196-677), 4 were lost to follow-up and 7 died. MRA
showed 5 delayed intracranial arterial anomalies in 4 patients, 4 stenosis and 1
dilatation, 4 pre-existing intracranial arterial stenosis and 1 pre-existing cervical
arterial stenosis. These all patients remained asymptomatic during FU period.
A significant clinical improvement was observed between 3 months and long-
term FU (p L0.0001), with a good outcome (mRS 2) achieved from 54.5% to
61% of patients. Health-related quality of life was better than that of unselected
patients with stroke.
Conclusion
Long-term FU of patients treated with Solitaire shows
asymptomatic arterial anomalies and fu rther clinical improvement, suggesting
that MET entails a systematic long FU including MRA.
B-0713 10:48
Safety and efficacy of a new device for the treatment of wide neck
bifurcation aneurysms: preliminary experience
M. Aguilar-Pérez, W. Kurre, S. Fischer, H. Bäzner, H. Henkes;
Stuttgart/DE (
[email protected])
Purpose: Wide neck bifurcation aneurysms (WNBA) are considered to belong
to the subgroup of aneurysms with increased difficulty and risks. Balloon- and
stent-remodelling are known techniques for their treatment. pCONus is a self-
expanding, completely retrievable, electrolytically detachable device with a
proximal shaft, 4 distal petals and a nylon cross in the distal end of the shaft.
The device is made to bridge the orifice of WNBA in order to allow better
control of the coil occlusion. It combines elements of "waffle cone" stent
deployment and the no longer available TriSpan Device. Our purpose was to
evaluate the safety and efficacy of this device for the treatment of WNBA.
Methods
and Materials: 25 consecutive patients underwent endovascular
treatment of WNBA using pCONus between February 2012 and May 2013.
Target vessels included the anterior circulation in 19 (76%) and the posterior
circulation in 6 (24%). 8 patients were treated in the setting of acute
subarachnoid haemorrhage (32%).
Results
Neither technical failure nor rupture was encountered. Acute thrombi
formation was observed in one patient (4%), which resolved after
administration a body weight adapted bolus dose of eptifibatide (Integrilin).
After the initial procedure, total occlusion was achieved in 7 (28%) patients and
a neck remnant was evident in 9 (36%). Follow-up angiography was available
in 21 patients and demonstrated complete occlusion in 13 (61.9%). Evident coil
compaction requiring re-treatment was observed in three patients. pCONus
also assisted re-coiling.
Conclusion
pCONus allows controlled coil occlusion of WNBA, both ruptured
and unruptured. Major complications are rare.
Author Disclosures:
M. Aguilar-Pérez: Consultant; Phenox, Covidien, ab medica. W. Kurre:
Consultant; phenox. H. Henkes: Consultant; Phenox, Covidien, Codman, Balt.
Founder; co-founder of phenox.
B-0714 10:57
Leptomeningeal collaterals in patients with proximal middle cerebral
artery occlusion are associated with shorter thrombus length and lower
thrombus burden
C.R. Trampedach, C. Ovesen, A. Christensen, H. Christensen;
Copenhagen/DK (
[email protected])
Purpose: Proximal middle cerebral artery occlusions (M1 occlusion) are often
but not always associated with severe stroke and poor outcome. The presence
of leptomeningeal collaterals can potentially reduce the acute ischemia and
thus reduce stroke severity. Occlusions and collaterals can be assessed using
computed tomography angiography (CTA). We assessed if leptomeningeal
collaterals covariate with the length of the thrombus and a thrombus burden
score.
Methods
and Materials: Eighty-one patients - subsequently diagnosed with a
M1 occlusion on CTA - were admitted within 4.5 hours after symptom onset
between May 2009 and December 2011. Occlusions and leptomeningeal
collaterals were evaluated on CTA; collaterals were scored according to the
amount of collateral supply filling the occluded middle cerebral artery territory.
Results
Eighty-one patients with a single M1 occlusion were included into the
analysis (60.5% female, 39.5% male, mean age 69 years, range 29-93 years).
There was no correlation between age and collateral score. Median thrombus
length at time of admittance was 15 mm (range 2-33), which correlated to the
collateral score (R= -0.376, p < 0.001). Median thrombus burden score was 4
(range 0-8) and a correlation with the collateral score was present (R=0.446,
p < 0.001).
Conclusion
Leptomeningeal collaterals on CT angiography relate to a shorter
proximal middle cerebral artery occlusion and a lower thrombus burden score.
S290
BA C D E F G
Sunday
B-0715 11:06
Leptomeningeal collaterals in patients with proximal middle cerebral
artery occlusion are associated with milder stroke and better functional
outcome after fibrinolysis
C.R. Trampedach, C. Ovesen, A. Christensen, H. Christensen;
Copenhagen/DK (
[email protected])
Purpose: Proximal middle cerebral artery occlusions (M1 occlusion) are often
associated with severe stroke and poor outcome. The presence of
leptomeningeal collaterals can potentially reduce the acute ischemia and thus
reduce stroke severity. Occlusions and collaterals can be assessed using
computed tomography angiography (CTA). Collaterals were scored according
to the amount of collateral supply filling the occluded middle cerebral artery
territory. We assessed the hypothesis that leptomeningeal collaterals
covariates with National Institutes of Heal th Stroke Scale (NIHSS) at time of
admission and with 3 month outcome after acute ischaemic stroke.
Methods
and Materials: Fifty-eight patients - subsequently diagnosed with a
M1 occlusion on CTA - were admitted within 4.5 hours after symptom onset
between May 2009 and December 2011. All patients were scored according to
NIHSS on admittance by a stroke-neurologist. Occlusions and leptomeningeal
collaterals were evaluated on nonenhanced CT and CTA. All patients received
fibrinolysis. Outcome was assessed by modified Rankin Scale (mRS) at 3
months.
Results
Fifty-eight patients with a M1 occlusion were included (57% female,
43% male, mean 70 years, range 42-93 years). There was no correlation
between age and collateral score. Median NIHSS at time of admittance was 15
(range 3-25), which correlated to the collateral score (R=-0.422, p < 0.001).
Median mRS at 3 months was 3 (range 0-6) and a correlation with the
collateral score was present (R=-0.361, p=0.007).
Conclusion
Leptomeningeal collaterals on CT angiography relate to lower
NIHSS on admission as well as less handicap after 3 months.
B-0716 11:15
Predictors of neurological deficit after endovascular treatment of cerebral
arteriovenous malformations and functional repercussion in prospective
follow-up
J.C. Llibre, J.A. Jordan; La Habana/CU (
[email protected])
Purpose: Endovascular therapy is a well established approach to treatment of
cerebral arteriovenous malformations (AVMs). The objective of this study was
to determine predictive factors of neurol ogical deficit following its application.
Methods
and Materials: 71 patients with cerebral AVMs, having undergone
147 embolisation sessions from 2006 to 2011 were followed up prospectively
(average of 31, 1 ± 17, 5 months). Functional neurological condition was
documented by means of the modified Rankin scale.
Results
Factors found to be predictors of neurological deficit were the partial
obstruction of drainage veins (OR=197.6; IC=2.76-1416.0; P=0.015), a positive
Result
in the Propofol test (OR=50.2; IC=6.18 - 566.5; P=0.000), AVM diameter
under 3 cm (OR=21.3; IC:1.71-265.6; P=0.018), the presence of intranidal
aneurysms (OR=11.2; IC=1.09 -114.2; P = 0.042), the absence of
postprocedure hypotension (OR=10.2; IC=1.35-77.7; P=0.003), deep venous
drainage (OR=7.14; IC=1.15 - 44.4; P =0.035), and devascularisation in excess
of 40% per session (OR=3.3; IC=1.11 - 16.8; P=0.056). 56 patients (78, 9%)
did not experience changes in their neurological condition after the treatment
and 13 patients (18, 3%) showed a new neurological deficit related to the
treatment. 95.8 % of the patients did not show significant long term incapacity.
Conclusion
Partial obstruction of drainage veins, small AVMs, intranidal
aneurysms, faulty hemodynamic control and extensive devascularisation were
found to be predictors of neurological defi cit. A significant number of patients
with neurological deficit improved in the long term.
B-0717 11:24
Angiographic reconstructions from whole-brain perfusion CT for the
detection of large vessel occlusion and recanalisation in acute stroke
J. Zhang, D. Geng; Shanghai/CN (
[email protected])
Purpose: The aim of this study is to assess the value of angiographic thin-slice
volume perfusion CT reconstructions for the detection of intracranial large
vessel occlusion and recanalisation after receiving intravenous thrombolytic
therapy in patients with stroke.
Methods
and Materials: Twenty-five patients with acute cerebral infarction
treated by recombinant tissue plasminogen activator (rt-PA) were enrolled in
this study. They all underwent admission and 24-hour whole-brain perfusion
CT. All images were obtained on a 256-slice multidetector CT scanner.
Dynamic 3D CT angiographic images (4-dimensional CTA) generated from
perfusion source data were obtained in all patients. Images were assessed for
the presence of intracranial vessel recanalisation. The cerebral hemodynamics
changes in distribution of ischemic lesions were analysed on perfusion
parameter maps.
Results
Of 25 patients with an infarct on follow-up imaging, 19 had infarcts in
the middle cerebral artery territory, 5 had infarcts in the posterior cerebral
artery territory, and 1 had an infarct in the internal carotid artery territory.
Average image quality scoring of baseline CT angiography (CTA) was the
same as one of 24-hours volume perfusion CTA (VPCTA) ( P> 0.05), 4 cases
with middle cerebral artery occlusion and one case with internal carotid artery
received partial recanalisation on 24-hours VPCTA.
Conclusion
In acute stroke, whole-brain PCT may be an optimal method to
evaluate patients for thrombolysis, detect intracranial arterial recanalisation of
cerebral arteries after receiving intravenous thrombolytic therapy, and have the
potential to decrease radiation dose and contrast media by substituting for
intracranial CTA in stroke CT.
B-0718 11:33
TRICKS MRA in the follow-up of coiled aneurysms: preliminary
evaluation
C. Sicignano, V. Piscitelli, M. Ferraioli, G. Buono, A. Generali, L. Delehaye;
Naples/IT (
[email protected])
Purpose: To evaluate the clinical utility of Time-Resolved Imaging of Contrast
KineticS (TRICKS) in MR for the follow-up of patients that underwent
endovascular treatments for intracranial aneurysms.
Methods
and Materials: From June 2008 to December August 2013 156
patients (with 161 aneurysms endovascularly treated) underwent simultaneous
TOF (Time Of Flight) and TRICKS MRA (Magnetic Resonance Angiography)
as follow-up of endovascular treatment of intracranial aneurysms (mean: 8
months after treatment, range: 3 to 17 months); DSA (Digital Subtraction
Angiography) was performed too, as gold standard (range: 1 to 9 months,
mean: 5 months, after MRA). MRA images were analysed independently by 2
senior radiologists and DSA by other two different radiologists. Findings were
assigned to 1 of 3 categories: complete obliteration (class 1), residual neck
(class 2) and recanalisation (class 3).
Results
TRICKS MRA showed a significantly higher agreement with DSA
technique in detecting aneurysm recanalisation compared to TOF-MRI
(agreement of 93% vs 75%).
Conclusion
Dynamic MRA in the form of TRICKS is relatively new imaging
modality with great potential; if compared to DSA, as in this report, it may
represent an efficient option to follow- up patients with intracranial aneurysms
treated by endovascular techiniques.
B-0719 11:42
Identification of risk groups in mechanical thrombectomy using the
pRESet stent-retriever: are there risk groups for procedure-related
complications?
T. Zoubi, R. Dziewas, J. Minnerup, W. Heindel, W. Schwindt, T. Niederstadt;
Münster/DE (
[email protected])
Purpose: Mechanical thrombectomy is an established method of
recanalisation in patients with acute stroke. Stent-retriever represents a new
kind of device. Our purpose was to identify patients with higher risk of
periinterventional complications.
Methods
and Materials: In our database of 159 interventional treated strokes,
we identified 52 patients (ø66±17 yrs) with acute thrombembolic occlusion of
MCA who underwent mechanical thrombectomy using the pRESet device
(Phenox, Bochum, Germany). In all patients NECT, CTA and PCT were
performed immediately before intervention. Grade of recanalisation was
measured using the TICI score. Duration of interventional procedure was
represented by the time from first diagnostic angiography to revascularisation.
Results
Successful recanalisation (TICI 2b or higher) was achieved in 46
patients (88.5%). 3 patients suffered from vasospams during intervention. In 4
patients thrombembolic complications occurred. Lower density of the occluding
thrombus led significantly more often to periinterventional complications
(57±5HE vs 66± 23HE, p=0.015). Thrombembolic complications occurred
significantly more often, if the patients age was 75yr (p=0.01). Angio-to-
recanalisation time tended to be longer in patients with higher vascular risk
score but did not show significance (p=0.086). Thrombus length, number of
passes of the device and vascular risk score had no influence on the number
of complications.
Conclusion
Mechanical thrombectomy using the pRESet stent-retriever
device is an effective method of recanalisation in patients with acute
thrombembolic occlusion of MCA. Complications associated with
thrombectomy occur, in our study significantly more often in patients with
higher age or lower density of thrombus. The dependence of thrombus density
and complication rate may originate from thrombus composition.
S291
BA C D E F G
Sunday
B-0720 11:51
Can a negative orbital-colour-Doppler-US examination avoid a diagnostic
cerebral angiography in patients with a clinical suspect of anterior-
draining intracranial-arterio-venous-fistulas?
G. Cristel, M. Venturini, S. Bianchi Marzoli, F. Simionato, G. Agostini,
A. Del Maschio; Milan/IT
Purpose: Digital subtraction angiography (DSA) represents the gold standard
technique to diagnose and treat IAVF. Orbital-colour-Doppler-ultrasound
(OCDUS) has already revealed itself to be useful in detecting dilated superior
ophthalmic vein (SOV) in patients with IAVF. We investigated whether a
negative OCDUS could avoid an invasive diagnostic cerebral angiography in
patients with clinical suspect of IAVF.
Methods
and Materials: Twenty-two consecutive patients with ophthalmic
signs suspecting IAVF were submitted to ophthalmologic examination, OCDUS
and DSA. Both eyes were studied with OCDUS (ATL-Philips HDI-5000/IU22, 5-
12-MHz linear-probe), performed by the same experienced operator. IAVF
diagnosis with OCDUS was based on the finding of SOV with reversed,
arterialised, and low-resistance (RI < 0.5) blood flow. Sensibility, specificity,
PPV, NPV and accuracy of OCDUS were calculated considering either number
of patients and total eyes (total=43), using DSA as gold standard.
Results
Considering the patients, 18/22 were positive at both OCDUS and
DSA (DSA demonstrated 18 dural and 2 carotid-cavernous-sinus-fistulas, 2
patients with bilateral involvement) and 4/22 were negative at both; hence,
sensibility, specificity, PPV, NPV, and accuracy of OCDUS were all of 100%.
Considering the eyes, 24/43 were positive at OCDUS and out of them a IAVF
was confirmed in 20/24 cases; 19/43 were negative at both OCDUS and DSA.
No false negatives were recorded at OCDUS. Therefore, sensibility, specificity,
PPV, NPV, and accuracy of OCDUS, respectively, were 100, 83, 83, 100, and
91%.
Conclusion
Our findings suggest that a negative OCDUS could avoid an
invasive DSA in patients with clinical suspect of IAVF.
10:30 - 12:00 Room L/M
Cardiac
SS 1303
Myocarditis, storage diseases and
diabetes
Moderators:
J. Bremerich; Basle/CH
T. Miszalski-Jamka; Kraków/PL
B-0721 10:30
Post-myocarditis scars underlying ventricular tachycardia:
correspondence between delayed-enhanced CMR or MDCT imaging and
electroanatomic mapping
A. Palmisano, A. Esposito, C. Colantoni, G. Maccabelli, F. De Cobelli,
P. Della Bella, A. Del Maschio; Milan/IT (
[email protected])
Purpose: The success of catheter ablation guided by electro-anatomic
mapping (EAM) in patients with recurrent ventricular tachycardia (VT) depends
on the effective identification of myocardi al scars. Preablation endocardial EAM
with bipolar voltages identifies with high accuracy post-ischemic scars. The
identification of post-myocarditis scars at EAM is challenging. The aim of the
study was to compare scars at different EAM approaches (bipolar-endocardial,
bipolar-epicardial, unipolar-endocardial, unipolar-epicardial) with late
enhancement at imaging.
Methods
and Materials: Nineteen patients (pts) with post-myocarditis VT were
enrolled. 15 pts underwent CMR including post-gadolinium IR-T1w sequences;
4 pts with ICD underwent MDCT including a delayed low-energy (80 kV) scan
for scars identification. Scar' site, extension and transmural distribution
(subendocardial, mid-wall, subepicardial, transmural) were evaluated at
imaging and compared with low voltages suggestive for scars at bipolar and
unipolar maps with endocardial and epicardial approach.
Results
19/19 pts had myocardial scars at LE imaging: in 9 pts, scars
involved myocardial wall from epicardium to midwall; in 10 pts, scars involved
only subepicardium. Segment per segment correspondence of LE scar
localisation with scars at EAM demonstrated that unipolar mapping is more
effective in the identification of imaging -revealed scars (71.1% for epicardial
map, 24.7% for endocardial map) to bipolar one (63.2% for epicardial map, 1%
for endocardial maps).
Conclusion
EAM may identify only upto 70% of post-myocarditis scar
substrate underlying VT recurrence. Hence, an imaging based on
characterisation of scar substrate should be always performed in these
patients before ablation.
B-0722 10:39
Detection of myocardial oedema in acute myocarditis with diffusion-
weighted imaging
A. Luna
1, J. Broncano2, T. Martin1, J. Sanchez-Gonzalez3; 1Jaén/ES,
2Córdoba/ES, 3Madrid/ES (
[email protected])
Purpose: To evaluate DWI detection capability of myocardial oedema in
patients with acute myocarditis in comparison to black-blood STIR (BB-STIR)
and its accuracy in combination with delayed gadolinium enhancement (LGE)
for the diagnosis of acute myocarditis.
Methods
and Materials: 24 patients (19 men and 5 women; mean age
37.4±15.54 years) with confirmed acute myocarditis were prospectively
submitted to cardiac MRI with high field scanners (1.5 and 3 Tesla) using
short-axis BB-STIR, LGE and whole cardiac DWI. We performed a SS-EPI-
DWI sequence with two b values (0 and 300 s/mm2) with cardiac and
respiratory triggering during the diastolic phase. Two readers with 14 and 2
years of experience reading cardiac MRI, blindly analyse the studies in two
different sessions: BB-STIR+LGE and DWI+LGE. Quality assessment of DWI
sequences was also performed (susceptibility and respiratory artefacts).
Results
The combination of BB-STIR and LGE demonstrated a sensitivity and
PPV of 100% for reader 1, 86% and 95.3% for reader 2, respectively. The
combination of DWI and LGE demonstrated a sensitivity and PPV of 95.6%
and 100% for reader 1, 95.6% and 95.3% for reader 2. There were no
significant differences in the evaluation of myocardial oedema and the
extension of the disease between both techniques (p > 0.05).
Conclusion
DWI with high b value is able to detect myocardial oedema in
patients with acute myocarditis in a similar manner to BB-STIR. The
combination of DWI and delayed enhancem ent shows similar sensitivity and
PPV for the diagnosis of acute myocarditis compared to BB-STIR and late
enhancement.
Author Disclosures:
J. Sanchez-Gonzalez: Employee; Philips Healthcare. Equipment Support
Recipient; Philips Healthcare.
B-0723 10:48
MRI findings in acute myocarditis and short-term clinical outcome
A. Vilaplana, J. Vivancos, M. Garcia, J. Marin, B. Perez; Sevilla/ES
(
[email protected])
Purpose: The aim of our study is to describe the most frequent and typical
MRI findings in acute myocarditis and to evaluate if these MRI findings
correlate with the severity of the disease and the short-term clinical outcome.
Methods
and Materials: We evaluated MRI imaging findings in 32 patients
with a clinical diagnosis of myocard itis. We also evaluated their clinical
outcome 6 months and one year after the acute onset of symptoms.
Results
Delayed gadolinium enhancement was present in 69% of patients on
the acute phase. The lateral left ventricular wall was the most frequent
segment involved. Subepicardial focal enhancement was the most typical
finding, present in 55% of patients, whereas 25% presented with
intramyocardial focal enhancement and 15% with lineal subepicardial
enhancement. Only 5% of these patients showed pericardial enhancement.
58% of patients with late enhancement showed T2 hyperintensity due to
oedema. 17% of patients presented with wall motion abnormalities. Left
ventricular telediastolic volume was slightly impaired in 2 patients, with
complete recovery on cardiac ultrasound two weeks after the acute episode.
Left ventricular function was preserved in all patients. Five months after the
onset of symptoms, all 6 patients who underwent a second MRI showed
persistent enhancement. Only 1 patient had persistent T2 hyperintensity.
Conclusion
We did not find any significant relationship between the presence
of delayed gadolinium enhancement and left ventricular function impairment
and also we did not find any significant relationship between the presence of
gadolinium enhancement in the acute phase and short-term clinical outcome.
B-0724 10:57
Cardiac magnetic resonance evaluation of right ventricle (RV) volumetric
and functional parameters in thalassaemia major patients: does the iron
affect the RV?
F. Pitocco
1, I. Di Giampietro1, C. Liguori2, A. Moscariello1, A. De Vivo1,
M. Romano1, F. Sorrentino1, B. Beomonte Zobel1; 1Rome/IT, 2Naples/IT
(
[email protected])
Purpose: TM patients could present a right heart involvement characterised by
RV failure related to chronic anaemia. It is still unknown if iron myocardial
deposition and iron overload can influence RV volume and function. Our aim
was to define the differences in volumetric and functional parameters between
patients with and without myocardial iron overload
Methods
and Materials: We enrolled 150
TM patients (mean age 37.8 ± 12.8
ys; mean body surface area Kg/m2 1.64± 0.24) who underwent to CMR for
functional LV-RV evaluation and LV iron assessment. All patients were under
iron-chelation therapy and none presented clinical or instrumental signs of
S292
BA C D E F G
Sunday
pulmonary hypertension or other cardiovascular comorbidity. RV volumes,
ejection fractions and masses were assessed. All parameters were indexed to
BSA
Results
We divided our population in patients with (T2* 20 ms) iron overload; 21% of TM patients showed myocardial iron
overload. We observed significant differences between the two groups in:
RVEF, stroke volume, end-systolic and end-diastolic volumes (p < 0.01),
characterised by RV higher volumes and RV-EF impairment in subjects with
cardiac siderosis. No significant differences in RV mass were observed
Conclusion
Cardiac siderosis can be associated with RV dysfunction and can
be considered as a contributor to heart failure in TM patients. These data must
be kept in mind in course of CMR for a correct clinical evaluation and
management in this setting of patients
B-0725 11:06
Cardiac magnetic resonance comparison of cardiac left-right ventricular
volumetric and functional parameters in thalassemia major and
thalassemia intermedia
A. De Vivo
1, F. Pitocco1, C. Liguori2, I. Di Giampietro1, A. Moscariello1,
F. Sorrentino1, B. Beomonte Zobel1; 1Rome/IT, 2Naples/IT
(
[email protected])
Purpose: T2*CMR is considered the most useful imaging technique to non
invasively assess myocardial iron overolad in Thalassemia patients.Our aim
was to assess myocardial iron overload in TM and TI patients,the relationship
between myocardial T2*values,LV-RV volumetric and functional parameters in
the two phenotypes of disease and to analyse differences in volumetric-
functional parameters
Methods
and Materials: 207 Patients (157
TM-50TI; mean age 37.8 ±12.8 ys;
mean Body Surface Area Kg/m2 1.64 ±0.24)underwent CMR examination
(Scanner 1.5 T,Avanto,Siemens-Germany). Myocardial iron load was
evaluated by T2*measurements;Volumes and Ejection Fractions were
analysed using the Steady State Free Precession (SSFP) sequences. All
parameters were indexed to body surface area.All
TM patients were under iron-
chelation therapy and blood transfusion support despite of TI subjects.None
presented clinical or instrumental sign s of pulmonary hypertension or other
cardiovascular comorbidity
Results
TI patients showed no cardiac iron overload whereas in 21% of TM
cardiac overload was found.In TI subjects not significant correlation was
detected between cardiac T2*and LV-RV volumetric-functional
modifications.Only in TM subjects statistically significant (p < 0.05)association
between myocardial T2*and LV-RV End diastolic-systolic Volumes was found;a
significant correlation between T2* values and EFLV-EFRV was noted.
Between TM and TI subjects a significant difference was noted in indexed
values of Stroke Volumes,Systolic Volumes,Diastolic Volume of LV-RV.No
relationship between cardiac mass modifications and T2* was found.
Conclusion
Myocardial iron overload is linked to a deterioration of
biventricular function and to an enlargement of LV-RV volumes in TM patients
while not significant relation with same parameters can be expected in TI
subjects mainly according to absence of cardiac iron load.
B-0726 11:15
Inter-observer reproducibility improvement of myocardial iron T2*
calculation using CNR-optimised composite image
P. Triadyaksa, A. Handayani, T.P. Willems, M. Oudkerk, P.E. Sijens;
Groningen/NL (
[email protected])
Purpose: Manual myocardial contouring contributes variability to the
determination of cardiac iron by T2* MRI. We evaluate the calculation of
Myocardial T2* by using CNR-optimised composite images on inter-observer
variability of myocardial contour determination.
Methods
and Materials: 36 short-axis slices from bright-blood T2* scans of 21
patients (9 hematological and 12 suspecte d of cardiomyopathy) were acquired
at 8 TEs (2.59-18.20 ms, 2.23 ms increment). Four independent observers
drew free-hand contours of left ventricular epicard and endocard on one
selected image and one CNR-optimised composite image per slice. The CNR-
optimised composite image was made by blending three TE images with
optimum CNR between the myocardium and its surrounding regions. The
calculated minimum mean myocard T2* values, determined for all segments
(i.e. 4-6 values per slice), varied between 7.05-36.75 ms. Dice Similarity
Coefficient (DSC) was used to assess similarity between observer's contours in
the two methods.
Results
Inter-observer agreement in all images (n=216) was improved in the
contouring of the CNR-optimised composite image (DSC of 0.844 ±0.032
median absolute deviation) compared to the subjectively-chosen image
(0.811±0.045), p < 0.001. In the presence of myocardial iron accumulation,
defined as T2* < 20 ms in at least one segment, the composite image also
showed significantly better contour agreement (0.842 ±0.032) compared to the
subjectively-chosen image (0.822 ±0.044), p < 0.001 (n=84). Furthermore, inter-
observer agreement of myocardial T2* improved when using the composite
image (r=0.956) rather than the subjectively-chosen image (r=0.915),
p < 0.001.
Conclusion
The CNR-optimised composite image improves inter-observer
reproducibility of myocardial T2* calculation as a measure of iron deposition,
by producing more consistent myocardial contours.
B-0727 11:24
Prevalence and clinical impact of left ventricular noncompaction (LVNC)
in -thalassaemia patients: a cardiac magnetic resonance evaluation
F. Pitocco1, I. Di Giampietro1, C. Liguori2, A. Moscariello1, A. De Vivo1,
G. Falchi1, F. Sorrentino1, B. Beomonte Zobel1; 1Rome/IT, 2Naples/IT
(
[email protected])
Purpose: LVNC is a congenital disorder, characterised by multiple and deep
trabeculations and a thickened ventricular myocardium with two distinct layers,
compacted and noncompacted. LVNC has been linked to several congenital
disorders while acquired cases have been described as "isolated LVNC". Its
prevalence is < 0.14% in adults referred for echocardiography. Few cases of
isolated LVNC in haematological disorders have been described. Our aim was
to assess LVNC prevalence in 2-thalassaemia patients and to evaluate its
potential association with cardiac siderosis
Methods
and Materials: We evaluated 300 patients with 2-thalassaemia
presenting for cardiac iron assessment by MRI. No patients had
neuromuscular or congenital heart diseases. 25% patients had myocardial iron
overload (T2* < 20 ms). Left-right ventricular volumes, masses and ejection
fractions were indexed to the body surface area. A LVNC diagnosis was
established according to the following criteria: (a) segmental LV wall thickening
with a thin compacted layer; (b) noncompacted vs compacted wall thickness
ratio > 2.5;(c) end-diastolic compacted layer < 4.5 mm
Results
34% patients fulfilled criteria for LVNC. There were no statistically
significant differences between patients with and without LVNC in cardiac
functional performance (ejection fraction; volumes). These data were
confirmed also comparing subjects with 2
segments
Conclusion
2-thalassaemia patients present a higher prevalence of LVNC
than normal population, in absence of conventional risk factors. A genetical
correlation between thalassaemia mutation and ineffective myocardial
development could be hypothesised. LVNC myocardium can be considered a
new feature to look for in course of cardiac MRI in thalassaemia studies
B-0728 11:33
Diagnostic value of late-enhanced multi-detector computed tomography
acquisition in cardiac amyloidosis
C.I. Mihalache, J. Mayer, T. Damy, A. Luciani, H. Kobeiter, A. Rahmouni,
J.-F. Deux; Créteil/FR (
[email protected])
Purpose: Evaluate diagnostic value of late-enhanced Multi-Detector
Computed Tomography acquisition in cardiac amyloidosis.
Methods
and Materials: Fifteen patients with amyloidosis (10 Transthyretin
Familial and 5 AL amyloidosis) and evidence of cardiac involvement on MRI,
and 12 control subjects, were included in this prospective study. All subjects
were scanned with a 128-slice MDCT. The protocol included a prospective
triggering and a delayed acquisition performed 5 minutes after injection of
contrast medium. Myocardial volume and mean myocardial density of left
ventricle (LV) were calculated from manual contouring of LV boundaries.
Region-of-interests were placed in the LV cavity and in the air outside the
patient in order to calculate blood density, myocardial signal-to-noise ratio
(SNR
myoc), blood SNR (SNR blood) and contrast-to-noise ratio (CNR) between
myocardium and blood within LV cavity (CNRmyoc-blood).
Results
Myocardial density and SNRmyoc were significantly (P < 0.05) higher in
patients with cardiac amyloidosis than in control subjects (117 ± 38 vs. 81 ± 16,
and 6.55 ± 2.8 vs. 4.88 ± 1.8). SNR blood didn't exhibit significant difference
between amyloidosis versus control subjects (8.10 ± 3.1 and 7.69 ± 3.0;
P=0.7). CNRmyoc-blood of amyloidosis patients was significantly lower comparing
to control subjects (1.55 ± 0.9 and 2.82 ± 1.3; P < 0.05). LV volume was higher
in amyloidosis patients (67 ± 46 mL) than in control patients (50 ± 28 mL) but
the difference was not statistically significant (P=0.28).
Conclusion
Late-enhanced MDCT can detect abnormal myocardial
enhancement in patients with cardiac amyloidosis and could prove useful in
patients requiring permanent pacing, contraindication for MRI.
S293
BA C D E F G
Sunday
B-0729 11:42
Predictors of arrhythmic events during the acute phase of
hemodynamically stable myocarditis: a cardiac magnetic resonance
study
L. Monti
1, L. Occhi1, C. Moro2, G. Iacuitti2, G. Bassanelli3, B. Nardi1, M. Lettino1,
L. Balzarini1; 1Rozzano/IT, 2Desio/IT, 3Castellanza/IT
(
[email protected])
Purpose: We searched for imaging predictors of arrhythmic events in patients
with hemodynamically stable acute myocarditis.
Methods
and Materials: There were 103 patients (pt) with hemodynamically
stable acute myocarditis. All of them were hospitalised from the E.R. in one of
the 3 centres (ICH Rozzano, P.O. Desio, Mater Domini Castellanza). Acute
myocarditis was diagnosed with MR in the presence of oedema and LGE.
Clinical, bioclinical, ECG and imaging data were reviewed by a panel
consensus of 1 cardiologist and 1 radiologist to adjudicate events.
Results
80 males (77.67%) and 23 females (22.33%), 95% in NYHA class I.
Mean EF = 58.6% ±10. During hospitalisation in 14 pz (13.6%) were observed
arrhythmic events including 1 torsades de pointes, 4 NSVT, and 1 sustained
VT. Only a reduced (i.e.: below normal reference range for MR studies) LVEF
was significantly associated with events, with OR = 8.4. Neither WBC count
(OR 1.14), troponin peak (OR=1.18), end-diastolic volume (OR=1.0), Late
Gadolinium Enhancement mass (OR=1.06) or T2 STIR edema mass (OR=1.2)
were related to arrhythmic events during the acute phase of myocarditis.
Conclusion
In hemodynamically stable patients hospitalised for acute
myocarditis, clinical events are mainly arrhythmic with a prevalence of 13.5%.
A reduced LVEF, evaluated with MR, is the only parameter associated with
clinical events during the acute phase of the disease.
B-0730 11:51
Diabetic cardiomyopathy: a cardiac magnetic study on progression of
function impairment
N. Galea, E. Giannetta, A. Isidori, M. Francone, C. Catalano, I. Carbone;
Rome/IT (
[email protected])
Purpose: Diabetic cardiomyopathy (DCM) is a complication of diabetic mellitus
and is characterised by high morbidity and mortality. It consists in a
progressive impairment of diastolic and systolic ventricular performance not
related to ischemic disease. The aim of our study was to explore with Cardiac
Magnetic Resonance (CMR) the alterations in myocardial contractility and
geometry in a cohort of selected patients over a four-year follow-up.
Methods
and Materials: 34 men with CMR findings suggestive of DCM
(increased angle of ventricular torsion,reduced myocardial strain,increased LV
mass, slightly increased end-diastolic volume[EDV] and concentricity index[LV
mass/ EDV]) performed a 4-year follow-up CMR study. All images were
analysed to assess EDVi, end-systolic vol ume (ESV), ejection fraction (EF),
myocardial mass index (LVMi), myocardial strain and ventricular torsion.
Results
Results revealed a decrease of myocardial strain ( ( from -12.6% to -
10.9%, p=0.03), a non-significant increase of torsion angle (from 19.1°to 19.2,
p=0.76), an increase of LVMi (from 132 g/m2 to 118.52 g/m2; p=0.014) and a
mild increase of EDVi (from 65.7 ml/m2 to 60.53 ml/m2, p=0.056) at
follow-up.͒The EF was unchanged (from 60.8% to 58.9%) and the
concentricity index showed no significant changes (from 2.1 g/ml to 2.0 g/ml,
p=0.51). Metabolic parameters showed no significant differences in glycemia
and glycosylated hemoglobin.
Conclusion
Early features of DCM are contractile dysfunction, increased
global angle of twist and LV concentric hypertrophy. A progressive dissociation
between myocardial contraction and ventricular torsion characterise late
dilative stages.
Author Disclosures:
N. Galea: Research/Grant Support; Grant from FIRB project 2010 - "Futuro in
Ricerca" program (Protocol No RBFR10URHP_003) of Italian Ministry of
Education, University and Research.
10:30 - 12:00 Conf. Room M3
Interventional Radiology
SS 1309
New techniques and applications
Moderators:
T. Andrasina; Brno/CZ
R. Uberoi; Oxford/UK
B-0731 10:30
MR-guided laser-induced interstitial thermotherapy of liver metastases
from breast cancer and other non-colorectal liver metastases: prognostic
factors for overall survival and progression-free survival
T.J. Vogl, N.N.N. Naguib, K. Eichler, H. Ackermann, V. Freier;
Frankfurt a. Main/DE (
[email protected])
Purpose: To retrospectively evaluate prognostic factors for progression-free
survival (PFS) and overall survival (OAS) after treatment of liver metastases
from breast cancer and other non-colorectal cancers with MR-guided laser-
induced thermotherapy (LITT).
Methods
and Materials: 401 patients (58 males, 343 females; mean age 57.3
years) with liver metastases from different primary tumours (breast cancer
n=271, neuroendocrine cancer n=21, others n=109) were treated with MR-
guided LITT between January 2000 and January 2011.
Results
Median OAS of all patients was 37.6 months starting calculation from
the date of first intervention with LITT. 1-year survival was 86.5%, 2-year
survival 67.2%, 3-year survival 51.9%, 4-year survival 39.9%, and 5-year
survival 33.4%. In patients with liver metastases from breast cancer, 1-year
OAS was 86.7%, 2-year OAS 66.9%, 3-year OAS 51.5%, 4-year OAS 40.3%,
and 5-year OAS 32.1% (median 37.6 months). 1-year PFS was 50.3%, 2-year
PFS 36.3%, 3-year PFS 28.4%, 4-year PFS 24.5%, and 5-year PFS 19.9%
(median 12.2 months). In patients with liver metastases from neuroendocrine
cancer 1-, 2- and the 3-year OAS rates reached 94.1%, 72.1% and 51.5%,
respectively (median 36.6 months). 1-year PFS was 50.6%, 2-year PFS 33.8%,
3-year PFS 26%, 4-year PFS 20.4% and 5-year PFS 17% (median 12.2
months).
Conclusion
MR-guided LITT of liver metastases from breast cancer and other
non-colorectal cancers results in a good OFS and PFS rates in comparison to
hepatic resection and other therapies. For both groups, the initial number of
metastases and their volume can be seen as the most important prognostic
factors for clinical success.
B-0732 10:39
MRI T1 treatment-monitoring during laser-induced thermotherapy of
hepatic metastases for necrotic size prediction
J.L. Wichmann, M. Beeres, B.M. Borchard, N.N.N. Naguib, B. Bodelle,
S. Zangos, T.J. Vogl, M.G. Mack, K. Eichler;
Frankfurt a. Main/DE (
[email protected])
Purpose: To investigate the accuracy of real-time MRI T1-based treatment-
monitoring for predicting lesion volume during laser-induced thermotherapy
(LITT) of hepatic metastases.
Methods
and Materials: 237 liver metastases in 151 patients were ablated
during 372 LITT procedures. 1.5 T MRI treatment-monitoring using longitudinal
relaxation time (T1) FLASH sequences was performed. Patients underwent
additional contrast-enhanced MRI directly after LITT, 24h after ablation and
during follow-up at 3, 6 and 12 months. The applied energy necessary for full
ablation within the various liver segments was investigated.
Results
Total amount of applied energy during LITT varied from 6.12 to
225.32 kJ (mean: 48.96 kJ) and peaked in the liver segments 5 (2.12 kJ/cm³)
and 8 (2.16 kJ/cm³). The preablative metastasis volume ranged from 0.5 to
51.94 cm³ (mean: 1.99 cm³; SD: 25.49 cm³) while the volume measured in the
last available T1 image varied from 1 to 120 cm³ (mean: 26.25 cm³; SD:
25.66 cm³). Volumes measured via T1-based treatment-monitoring showed a
stronger correlation with necrosis 24 h after LITT (r = 0.933; p < 0.001) than
contrast-enhanced MRI directly after the procedure (r = 0.888; p < 0.001).
Conclusion
Real-time MRI T1 treatment-monitoring during LITT of hepatic
metastases enables precise estimation of the resulting lesion volume and
improves control of the energy necessary during ablation.
S294
BA C D E F G
Sunday
B-0733 10:48
Initial clinical experience with a quadrupole butterfly coil for spinal
injection interventions in an open MRI system at 1.0 Tesla
M. Jonczyk1, B. Hamm1, A. Heinrich2, A. Thomas1, H. Rathke1,
B. Schnackenburg3, F. Güttler2, U. Teichgräber2, M. de Bucourt1; 1Berlin/DE,
2Jena/DE, 3Hamburg/DE (
[email protected])
Purpose: To report our initial clinical experience with a new MRI quadrupole
coil which allows interventions in prone position.
Methods
and Materials: Fifteen patients (7 women, 8 men; average patient
age 42.8 years) were treated in a 1.0 Tesla Panorama High Field Open (HFO)
MRI system (Panorama HFO) using a quadrupole butterfly coil (Bfly) and
compared with 15 patients matched for sex, age, and MR intervention using
the MultipurposeL coil (MPL) performed in conventional lateral decubitus
position (all, Philips Medical Systems, Best, The Netherlands). All interventions
were performed with a near-real-time proton density turbo spin echo (PD TSE)
sequence (TR/TE/flip angle/ta: 600 ms/ 10 ms/ 90°/ 3 s/image). Qualitative and
quantitative image analysis was performed including signal intensity, signal-to-
noise and contrast-to-noise ratio (SNR, CNR), contrast and full width at half
maximum (FWHM) measurements.
Results
Contrast differed significantly between the needle and muscles (Bfly
0.27/MPL 0.17) as well as the needle and periradicular fat (0.13/0.24) during
the intervention (both, p=0.029), as well as CNR between muscles and the
needle (10.61/5.23;p=0.010) although the FWHM values did not
(2.4/2.2;p=0.754). Signal intensity of the needle in interventional imaging
(1152.9/793.2;p=0.006), and postinterventional SNR values of subcutaneous
fat (15.3/28.6;p=0.007), muscles (6.6/11.8;p=0.011), and the CNR between
these tissues (8.7/17.5;p=0.004) yielded significant differences.
Conclusion
The new coil is a valid alternative for MR-guided interventions in
an open MRI system at 1.0 Tesla, especially if patients cannot (or prefer not to)
be in a lateral decubitus position, or if prone positioning yields better access to
the target zone.
B-0734 10:57
Single centre experience of extending indications for percutaneous
intraportal pancreatic islets auto-transplantation after pancreatic surgery
to prevent type-1 diabetes: feasibility, technical aspects, complications,
and clinical outcome
G. Agostini, M. Venturini, P. Maffi, G. Balzano, L. Piemonti, A. Del Maschio;
Milan/IT (
[email protected])
Purpose: Percutaneous islet allo-transplantation, needing
immunosuppression, is a traditional less invasive alternative to surgical
pancreas transplantation for brittle-type-1 diabetes, while PIPIAT, not needing
immunosuppression, is usually performed after pancreatic surgery for chronic
pancreatitis to prevent diabetes. Our aim was to assess feasibility, technical
aspects, complications and clinical outcome of PIPIAT following pancreatic
surgery, not only for chronic pancreatitis but also for benign and malignant
nodules.
Methods
and Materials: From 2008 to 2012, 41 patients were enrolled for
PIPIAT 24/48 hours after pancreatic surgery (total pancreatectomy, distal
pancreatectomy for benign/borderline neoplasms of pancreatic body-neck).
PIPIAT was performed using a combined US and fluoroscopy-guided
technique (4-F catheter): PIPIAT feasibility, complications, median-follow-up,
metabolic (insulin independence rate, graft function based on 2-score, marker
of islet function) and oncologic (mali gnant and metastatic diseases) outcomes
were recorded.
Results
PIPIAT wasn't performed in 7/41 patients (4 for inadequate islet
mass, 2 for hemodynamic instability, 1 for islet culture contamination), while it
was successfully performed in 34/34 patients. PIPIAT-related complications
occurred in 8 patients (23.5%): 4 bleedings (2 requiring transfusions), 3 portal
thromboses (1 complete, 2 partial), 1 sepsis. Median follow-up duration was
546 days. Insulin independence was achieved in 15/34 patients (44%), partial
graft function in 16/34 patients (47%), no function in 3/34 patients (6%).
Seventeen patients had malignancy; none of them developed liver metastases
during follow-up.
Conclusion
PIPIAT, performed under a combined US and fluoroscopy
guidance and not requiring immunosuppr ession, is feasible, with a relatively
low complication rate and a better metabolic outcome than allo-transplantation.
B-0735 11:06
Safety and mild-term permeability of ePTFE-covered portosystemic
shunts (TIPS) in children
L. Zurera, J. Espejo, S. Lombardo, M. Canis, J. Gilbert, C. Villen; Cordoba/ES
(
[email protected])
Purpose: To analyse retrospectively the safety and efficacy of ePTFE-covered
TIPS in children.
Methods
and Materials: We present 12 children (average-age 9 and weight
30 kg)who received implants of 10-mm-diameter Viatorr ePTFE-covered
endoprostheses for acute (n=7) or recurri ng upper-gastrointestinal bleeding
(UGB) (n=4) caused by medically or endoscopically uncontrollable varices. All
the children had liver disease of differing causes, three with chronic portal
thrombosis and cavernomatosis. The recurrence of UGB, associated
complications and permeability were assessed with Doppler ultrasound
sequentially or up to transplantation.
Results
In all the children, a single endoprosthesis was implanted in a single
session, without mortality. The mean initial transhepatic gradient was 15 mmHg
(3-21 mmHg), which dropped to 7 mmHg (1-12 mmHg) after TIPS implant.
Immediate complications observed were mild encephalopathy (1) and acute
occlusion TIPS (1) which was resolved with the implant of a coaxial
endoprosthesis. Stenosis of the TIPS (1) was observed at 9 months and two
complete thrombosis was observed: portal cavernomatosis of a liver
transplantation at 7 months and another one at 12 months; all were resolved
with angioplasty and coaxial endoprostheses. Four children received
transplants at 7- 9-10-17 months, with permeability of the TIPS observed. In
the other eight, permeability was demonstrated with Doppler ultrasound during
a mean follow-up period of 18 months (primary permeability=67% and
secondary permeability=100%).
Conclusion
Our results indicate the safety and permeability of Viatorr ePTFE-
covered endoprostheses for the treatment of UGB due to gastroesophageal
varices can be good, a fact that needs to be corroborated with larger series in
the future.
B-0736 11:15
Percutaneous transhepatic cholangioscopic lithotripsy for the treatment
of intrahepatic stones
A. Cannavale, M. Corona, F. Fiocca, P. Lucatelli, F. Cereatti, C. Cirelli,
G. Fanello, F. Fanelli, F.M. Salvatori; Rome/IT
(
[email protected])
Purpose: To assess the safety and effectiveness of percutaneous transhepatic
cholangioscopic lithotripsy (PTCSL) for the treatment of hepatolithiasis in
hostile abdomen.
Methods
and Materials: From January 2011 to July 2013 we assessed 43
patients who underwent PTCSL. All patients performed pre-operative CT
and/or MRCP to assess the location of intrahepatic stones and post-operative
anatomy. PTCSL was performed using 2.8-mm cholangioscope (Olympus CHF
CB30/S) with electrohydraulic shock-wave lithotripsy probes. This was
performed through a biliary percutaneous access previously obtained by
inserting a biliary drainage (10 Fr). After the procedure, a biliary catheter was
left in place to make a cholangiographic follow-up.
Results
All patients had prior complex hepatobiliary operations (i.e.
duodenocefalopancreasectomy). The median duration of the condition prior to
PTCSL was 6 (3-12) months. In all cases, stones were fragmented during the
first procedure. There was minimal intraope rative blood loss. Median size of
bile duct was 15 mm prior to the procedure. The number of stones ranged from
one to five with the largest size of stone comparable to the size of bile duct.
The median follow-up was 12 months. Forty-one patients were symptom free
with neither stone recurrence nor cholangitis immediately after the procedure
or during follow-up. No bleeding or deaths were encountered. Only two
patients had a transient episode of cholangitis with fever and chills immediately
after the procedure.
Conclusion
PTCSL is a feasible and an effective treatment method for
patients with recurrent biliary stone, following complex abdominal surgery as
the success rate from endoscopic procedures is limited.
B-0737 11:24
Ozone augmented percutaneous discectomy: a novel minimally invasive
alternative to surgical discectomy in patients with refractory discogenic
sciatica?
M.T. Crockett, M. Moynagh, N. Long, K. Synnott, S. Eustace; Dublin/IE
(
[email protected])
Purpose: Discogenic sciatica is a prevalent and debilitating condition. Multiple
minimally invasive treatment options are available with none demonstrating
definitive equality or superiority to surgical discectomy. Automated
percutaneous discectomy and intradiscal ozone therapy are established
minimally invasive treatment options which have shown promise in cohorts of
patients in whom first line therapies have failed. The purpose of this study was
to assess the safety and efficacy of a novel combination treatment option;
ozone augmented percutaneous discectomy (OAPD).
Methods
and Materials: 100 patients were included in the study, all with a
diagnosis of discogenic sci atica confirmed following lumbar spine MRI and
examination by a consultant orthopaedic surgeon. All patients had failed first
line therapies of 6 weeks physiotherapy and subsequent caudal epidural
injection (post treatment McNab score of 1). These patients then underwent
combination treatment of OAPD performed by an experienced musculoskeletal
radiologist. Patient follow-up ranged from 6-18 months. Outcome measures
were McNab clinical outcome score and requirement to undergo subsequent
surgical discectomy.
S295
BA C D E F G
Sunday
Results
Over 70% of patients recorded significant symptomatic improvement
eliminating the requirement for operative intervention whilst the remainder
proceeded to undergo surgical discectomy. Average McNab clinical outcome
score following OAPD was 3.6. No significant intra or post-procedural
complications were recorded.
Conclusion
OAPD is a safe and effective novel minimally invasive treatment
option in a cohort of patients with confirmed discogenic sciatica in whom first
line treatment options have failed. Further research is required to assess
longer term outcomes and to directly compare OAPD with surgical discectomy.
B-0738 11:33
Percutaneous vertebroplasty in adult degenerative scoliosis for spine
support: study for pain evaluation and mobility improvement
G. Velonakis, D. Filippiadis, A. Mazioti, M. Tsitskari, E. Brountzos, N. Kelekis,
A.D. Kelekis; Athens/GR (
[email protected])
Purpose: To evaluate efficacy and safety of percutaneous vertebroplasty (PV)
as primary treatment in adult degenerative scoliosis.
Methods
and Materials: During the last 4 years, PV was performed in 18 adult
patients (68 vertebral bodies) with back pain due to degenerative scoliotic
spine. Under anaesthesia and fluoroscopy, direct access to the most deformed
vertebral bodies was obtained using 13G needles and PMMA for
vertebroplasty was injected under continuous fluoroscopic control. The inner
arch of scoliosis was supported. Clinical evaluation included immediate and
delayed follow-up studies of patient's general condition and neurological status.
A NVS scale on a questionnaire helped assessing pain relief degree, life
quality and mobility improvement.
Results
Comparing the patients' scores prior to vertebroplasty (mean value
8.06±1.3 NVS units), the morning after (mean value 3.11 ±1.2), at 12 (mean
value 1.67±1.5) and 24 months post vertebroplasty (mean value 1.67 ±1.5 NVS
units), patients of our study presented a mean decrease of 6.39 ±1.6 NVS units
on terms of life quality improvement and pain relief (p < 0.001). Overall mobility
improved in 18/18 (100%) patients. No complications were observed. During
the follow-up period (mean value 17.66 months) patients underwent a mean of
1.3 sessions for facet joint and nerve root infiltrations.
Conclusion
Percutaneous vertebroplasty in the inner arch seems to be an
effective technique for supporting adult degenerative scoliotic spine. It can be
proposed as an initial treatment in the scoliosis of the elderly prior to surgery.
Preliminary results report significant pain reduction and mobility improvement,
but further studies are required.
Author Disclosures:
A. Kelekis: Consultant; Benvenue Medical.
B-0739 11:42
CT-guided screw fixation of vertical sacral fractures in local anaesthesia
using a standard CT
G.W. Reuther, U. Röhner, T. Will, I. Dehne, U. Petereit;
Saalfeld/DE (
[email protected])
Purpose: To evaluate time efficiency, radiation dose, precision and
complications of percutaneous iliosacral screw placement under CT-guidance
and local anaesthesia.
Methods
and Materials: Retrospective analysis of 143 interventions in 135
patients during a period of 42 months. Implant failures could be evaluated in
85/182 screws and bony healing or refracturing in 46/182 screws.
Results
A total of 182 iliosacral screw placements in 179 vertical sacral
fractures (105 unilateral, 37 bilateral) took place in 135 patients. No screw
misplacements including the simultaneous bilateral procedures were noted.
The average time for a unilateral screw placement was 23 minutes (range: 14 -
52 minutes) and 35 minutes (range: 21 - 60 minutes) for simultaneous bilateral
screwing. The dose length product was 365 mGy*cm (range: 162-
1014 mGy*cm) for the unilateral and 470 mGy*cm (range: 270-1271 mGy*cm)
for the bilateral procedure. In relation to the previous diagnostic CT of the
pelvis the dose length product was 0.95 (SD: 0.33) for unilateral and 1.10 (SD:
0.19) for bilateral screws. 1 gluteal bleeding occurred as the only significant
acute minor complication (0.7%). Backing out of 12/85 screws occurred
between 6 and 69 days after intervention. In 8 patients contralateral stress
fractures were detected after unilateral screw placement.
Conclusion
CT-guided iliosacral screw placement in sacral fractures is a safe
tool providing a high precision. The radiation dose is in the order of a
diagnostic CT of the pelvis for both unilateral and bilateral screws.
Contralateral stress fractures in unilateral screw placements must be
considered during the first weeks after intervention.
B-0740 11:51
Combined implantation of central venous access ports and percutaneous
radiological gastrostomy in patients with malignant disease is feasible
and safe
A.R. Keulers, A. Stamm, A.H. Mahnken; Marburg/DE
Purpose: To evaluate the feasibility, safety and patient tolerance of combined
central venous totally implantable access ports (TIAP) and percutaneous
radiological gastrostomy (PRG) implantation in patients with advanced stage
malignant disease.
Methods
and Materials: From 01/2010 to 07/2013 70 patients (61.7 ±10.25
years; 54 men, 16 women) underwent fluoroscopy-guided TIAP via the internal
jugular vein and PRG during a single session. Indications for port and
gastrostomy were advanced malignancy with the need of chemo or radiation
therapy. Minor and major-complications during the acute (0-24h), early (1-30d)
and late phase (> 30d) were recorded according to the Society of Interventional
Radiology classification and analysed retrospectively. As standard of care
patients were questioned about their opinion regarding the combined
procedure.
Results
For TIAP the following complications occurred: port infection with
consecutive explanation (major: n=1; 1.4%), thrombosis (minor: n=1; 1.4%).
For PRG one acute complication in terms of insufficient gastropexy followed by
CT-guided PRG occurred (n=1; 1.4%). In 69 cases, PRG was successful with
no early or late major-complications. Altogether 33 minor complications were
noted, 10 in early (14.3%) and 23 in late phase (32.8%). Most minor
complications were due to incorrect handling (n=20; 60.6%) resulting in local
infection, dislocation or material defect. 94% of the patients preferred the
combined intervention over two separate procedures.
Conclusion
Combined TIAP and PRG-implantation is feasible and safe with
complication rates comparable to those reported in literature while having an
excellent patient acceptance.
10:30 - 12:00 Board Room A
Paediatric
SS 1312
New imaging applications
Moderators:
K. Rosendahl; Bergen/NO
I. Sefic-Pasic; Sarajevo/BA
B-0741 10:30
Using intravoxel incoherent motion MR imaging to predict vesicoureteral
reflux in children with upper urinary tract infection: preliminary results
J. Kim, C. Lee, Y. Park, J. Lee, J. Choi, K. Kim, C. Park; Seoul/KR
(
[email protected])
Purpose: To compare diffusion parameters of intravoxel incoherent
motion (IVIM) diffusion-weighted imaging (DWI) between "reflux" and "non-
reflux" kidneys, and to evaluate feasibility of IVIM DWI in predicting
vesicoureteral reflux (VUR) in children with upper urinary tract infection (UTI).
Methods
and Materials: This retrospective study was approved by our
institutional review board and the requirement for informed consent was
waived. Sixty-three kidneys of 39 pediatric patients with upper UTI were
included and classified into "reflux" a nd "non-reflux" groups according to the
presence of VUR on VCUG. DWI using IVIM was performed with eight b
factors. ADC, true diffusion coefficient (D), pseudo-diffusion coefficient (D*),
and perfusion fraction (F) were measured and compared in renal pelvis of both
groups. Four indeces (D*/ADC, F/ADC, D*/D, and F/D) were also calculated
and ROC curve analyses were performed for each index to identify optimal cut-
off value that can predict VUR.
Results
VURs were detected in 17 kidneys on VCUG. In "reflux" group, ADC
values were significantly lower (2.87 ±0.27vs.3.15±0.39×10
-3 mm2/sec,
p=0.004), and D* and F values were significantly higher than "non-reflux" group
(41.50±12.38vs.30.01±10.47×10-3 mm2/sec, p < 0.001, and
0.31±0.12vs.0.22±0.14, p=0.018, respectively). Four indeces (D*/ADC, F/ADC,
D*/D, and F/D) were all significantly higher in "reflux" group than "non-reflux"
group (p=0.004,< 0.001,< 0.001 and 0.011,respectively). Among them, area
under ROC curve for D*/ADC was highest (0.803), and optimal cut-off value of
10.87 corresponded to 82.35% sensitivity and 71.74% specificity for detecting
VUR.
Conclusion
D* and F values are significantly higher and ADC values are
significantly lower in renal pelvis of "refl ux" kidney than "non-reflux" kidney. Our
new index (D*/ADC) can be useful for predicting VUR.
S296
BA C D E F G
Sunday
B-0742 10:39
Role of noninvasive acoustic radiation force impulse imaging to predict
complications in post-liver transplanted paediatric patients
M. Salsano, M. Candusso, G. Torre, G. Soglia, A. Pietrobattista, C. Grimaldi,
P. Tomà, J. de Ville de Goyet, L. Monti; Rome/IT (
[email protected])
Purpose: Acoustic radiation force impulse (ARFI) imaging has been developed
as a noninvasive ultrasound-based elastography modality to assess graft
fibrosis after orthotopic liver transplantation (OLT), estimated as tissue
stiffness. This method has attempted to replace periodical biopsy. The aim of
this study was to evaluate the clinical utility of ARFI imaging to detect
complications after paediatric OLT, in comparison with histopathologic findings.
Methods
and Materials: We periodically performed liver stiffness
measurements by ARFI imaging in 54 paediatric OLT recipients (evaluated
from 1 month to 2 years from the transplantation). In each recipient, the shear-
wave velocity (SWV) was measured ten times to quantify hepatic stiffness.
Liver biopsy and laboratory analysis (including functional liver markers) were
performed in a range of time from one day to one month from the ARFI
imaging.Collected data were evaluated retrospectively.
Results
Median SWV was higher in patients with clinical, biochemical and
histological signs of graft rejection than in patients without evidence of liver
disease [2.13m/s, 95% confidence interv al (CI) 1.84-2.42]. Median SWV values
in patients with only hepatitis or fibrosis were respectively 1.41m/s (95% CI,
1.25-1.56) and 1.67m/s (95% CI, 1.26-2.07). The median value of the ARFI
measurements in normal patients was 1.27m/s (95% CI 1.17-1.36).
Conclusion
ARFI was a reliable, noninvasive and rapid method able to
predict the diagnosis of graft disfunc tion in paediatric OLT. Liver stiffness
measurements correlated with histopatholog ic findings. ARFI could be useful to
postpone the time of liver biopsy and guide the immunosuppressive first line
therapy.
B-0743 10:48
High temporal versus high spatial resolution in MR quantitative
pulmonary perfusion imaging of 2-year-old children after congenital
diaphragmatic hernia repair
M. Weidner, F.G. Zöllner, C. Hagelstein, K. Zahn, T. Schaible, L. Schad,
S.O. Schönberg, K.W. Neff;
Mannheim/DE (
[email protected])
Purpose: Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia.
Using dynamic contrast-enhanced (DCE) MR imaging, lung perfusion can be
quantified. As according to Monte Carl o simulations, MR perfusion values
depend on temporal resolution; we compared two protocols to investigate if
ipsilateral lung perfusion is impaired after CDH, if simulation results can be
confirmed and which protocol should be preferred.
Methods
and Materials: DCE-MRI was performed in 36 2-year-old children
after CDH on a 3 T MRI system. Protocol A (n=18) based on a high spatial (3.0
s; voxel: 1.25 mm3) and protocol B (n=18) on a high-temporal resolution (1.5 s;
voxel: 2 mm³). Pulmonary blood flow (PBF), pulmonary blood volume (PBV)
and mean transit time (MTT) were calculated. Peak contrast to noise ratio
(PCNR) was calculated.
Results
Mean PBF was significantly reduced on the ipsilateral side, i.e. for
protocol A, PBFipsilateral was 45 ±26 ml/100 ml/min compared to
PBFcontralateral (63 ±28 ml/100 ml/min; p=0.0016) and for protocol B side-
differences were equivalent (PBFipsilateral=62 ±24 vs.
PBFcontralateral=85±30 ml/100 ml/min; p=0.0034). PCNR was significantly
higher for protocol B (30 ±18) than for protocol A (20 ±9; p=0.0294). Protocol B
showed higher values of PBF in comparison to protocol A (p always < 0.05).
Conclusion
In 2-year-old children, after CDH repair ipsilateral lung perfusion
is reduced. Higher temporal resolution and increased voxel size show a gain of
PCNR and significantly decrease the by Monte-Carlo simulated
underestimation of PBF. Protocol B should therefore be preferred, as a 2 mm
3
isotropic voxel resolution is still sufficient to detect side-differences of lung
perfusion.
B-0744 10:57
Elastosonography evaluation of testes with varicocele in paediatric
patients, preliminary results
C. Bruno, A. Bucci, R. Pozzi-Mucelli; Verona/IT (
[email protected])
Purpose: To determine whether elastosonography is able to detect differences
in the testicular elasticity between normal testes and testes with varicocele.
Methods
and Materials: 13 boys (9-13 years old) with untreated varicocele
(bilateral in 3 boys and left unilateral in 10) and 12 age-matched healthy
subjects underwent elastosonography. Varico cele was classified from a clinical
point (stage I: palpable only during the Valsalva maneuver - VM; II: palpable at
rest; III: visible at rest) and considering the duration of reflux at Doppler ( short:
detectable only during the VM; medium: lasting some seconds after the VM;
long: independent of the VM). The testicular elasticity was expressed as an
arbitrary three-point scale (1: normal; 2: slightly-moderately stiffer than normal;
3: severely stiffer than normal).
Statistical analysis was performed by means of the Student's t-test.
Results
The clinical stage of varicocele was I in 2 cases, II in 9 and III in 5;
the reflux was short in 3 cases, medium in 6 and long in 7. The elasticity was 1
in all 34 normal testes, 2 in 9 testes with varicocele and 3 in 7. The differences
in the degree of elasticity between normal testes and testes with varicocele
and between long-duration and medium/short-duration varicocele were both
statistically significant ( P
< 0.001); the difference between stage III and stages
I/II varicocele was just below significance (P = 0.053).
Conclusion
Testes with varicocele are significa ntly stiffer than normal ones,
with a positive correlation to both the clinical stage and the duration of reflux.
B-0745 11:06
Correlation between post-mortem computed tomography and magnetic
resonance imaging and autopsy findings in paediatric forensic imaging
N. Berkovitz, M. Vasserman, P. Gottlieb, S. Tal; Zerifin/IL
(
[email protected])
Purpose: To examine the cause of death using imaging in the paediatric
population and the agreement between autopsy and imaging findings. To
evaluate the feasibility of imaging to determine cause of death to reduce
paediatric autopsies.
Methods
and Materials: From Jan 2011 to Jan 2013, we performed CT and
MRI imaging of 41 cases under 18 years of age. We examined the imaging
findings and compared the findings for those autopsied.
Results
Imaging studies were performed for 41 children (average age
4.5 ± 5.4, 34 younger than 10) with 24 (59%) autopsied. CT was performed on
40, combining MRI in 15 and only MRI in one. There were 19 trauma and 22
non-trauma cases. Imaging showed cause of death for the 9 cases autopsied.
For 10 cases, cause of death was based on imaging only. For the 22 non-
trauma cases, 15 were autopsied (68%). With imaging, pneumonia was cause
of death for 18 cases (81% of non-trauma, 44% of total) with 13 (72%)
confirmed by autopsy. One autopsy confirmed cause of death was
hyperthermia and one aortic rupture. There were complementary findings for
imaging and autopsy in 4 cases, not significantly changing the cause of death.
Conclusion
Post-mortem imaging studies should be an inseparable part of
the post-mortem examination in all paediatric forensic investigation.
Pneumonia is common in non-trauma paediatric death. Once traumatic or
criminal involvement has been excluded by imaging, invasive autopsy can be
limited.
B-0746 11:15
Quantitative cerebral perfusion imaging at 3.0 T after congenital
diaphragmatic hernia repair and ECMO therapy with or without common
carotid artery occlusion
C. Hagelstein, F.G. Zöllner, M. Weidner, C. Weiss, S.O. Schönberg,
T. Schaible, K. Zahn, K.W. Neff; Mannheim/DE (
[email protected])
Purpose: To quantify cerebral perfusion in children after congenital
diaphragmatic hernia (CDH) repair with right common carotid artery (rCCA)
occlusion after extracorporeal membrane oxygenation (ECMO) therapy and to
assess whether CCA occlusion leads to impaired cerebral perfusion.
Methods
and Materials: Using pulsed arterial spin labelling (pASL; TR/TE
2474.6/21 ms, FOV 210x210 mm
2, section sickness 8 mm, voxel resolution
2.2x2.2x8 mm3; measurements 60, TI 1 700 ms, TI 2 1800 ms, TI 1s 1600 ms;
Magnetom Trio, Siemens Healthcare Sector, Germany) cerebral perfusion was
evaluated and quantified in 29 2-year-old children (2.1 ±0.2 years) after CDH
repair. In 14 patients, the rCCA was occluded after ECMO therapy. 15 patients
without ECMO and normal brain supplyin g circulation served as controls. 2
cortical (containing cortical gray matter) and subcortical (containing subcortical
gray and white matter) ROIs were placed in both hemispheres of each child
based on ASL images superimposed with anatomic reference images.
Results
Patients with rCCA occlusion showed significantly lower subcortical
perfusion for the right hemisphere with regional cerebral blood flow (rCBF) of
68.8±23.6 vs. 79.1± 30.5 ml/100 g/min left-sided, p=0.011. Cortical perfusion
showed a trend for reduced perfusion on the right side with rCBF 65.9 ±24.5 vs.
72.2±29.0 ml/100 g/min, p=0.138. Patients with normal rCCA flow
demonstrated identical cerebral perfusion bilaterally (p=0.780 and 0.340). In
nearly one third of the children with rCCA occlusion right rCBF was reduced
more than 20%.
Conclusion
After ECMO therapy and decannulation, ligation or reconstruction
of the CCA can be performed. Based on the possible hypoperfusion of the
hemisphere, with no complete collateralisation, reconstruction should be
preferred, even if secondary occlusion can occur.
S297
BA C D E F G
Sunday
B-0747 11:24
Optimisation of time-resolved CE-MRA of the thoracic vasculature in
Fontan patients: a quantitative approach
K. Jaspers, M.C.L. Peek, D. Wolff, M.J.W. Greuter, T. Ebels, T.P. Willems;
Groningen/NL (
[email protected])
Purpose: To optimise first-pass (FP) imaging of the cavo-pulmonary
connection in Fontan patients with time-resolved contrast-enhanced MR
angiography (TR-MRA) by identifying protocol-related factors that contribute to
vessel enhancement.
Methods
and Materials: TR-MRA was performed in 38 patients (age:8-44
years, median 16 years) with a total cavo-pulmonary Fontan connection on a
1.5 T MR system using a T1-weighted 3D gradient-recalled echo sequence. K-
space was undersampled using a TWIST protocol. TR/TE were 2.8/1.1 ms,
and flip angle was 25°. Reconstructed voxel size was 0.78×0.78×1 mm3.
Acquisition time per phase ranged from 4.3 to 9.0s. After injection of
0.1 mmol/kg gadobenate dimeglumine (MultiHance, Bracco) at injection rate
IR=0.9 mmol/s, 11 phases were acquired. Signal enhancement curves
(SE=SI (t)/SIpre) were measured in the pulmonary arteries (PA), superior and
inferior venae cavae (SVC and IVC), and the aorta. For each patient, the
maximum concentration in the aorta and SVC were estimated using the
cardiac output (CO) with Cmax (aorta)=IR/CO and
Cmax (svc)=3xCmax (aorta).
Results
During first pass, the Fontan connection could generally not be
visualised. Signal enhancement was significantly lower (p < 0.01) in the SVC
(SE=1.5±0.6) and PA (SE=2.0± 1.4) compared to the aorta (SE=4.7 ±1.1).
Estimated Cmax (svc) was high: 18-72 mmol/L. However, no correlation
between Cmax and SE was found. In the IVC, SE was 1.2± 0.5, resulting in
inadequate visualisation.
Conclusion
First-pass TR-MRA of the cavo-pulmonary connection was
suboptimal due to a too high concentration in the SVC and resultant image
degrading T2* effects and low concentration in the IVC. Initial results
demonstrate improved visualisation when contrast injected was in the foot.
B-0748 11:33
Placental diffusion MR imaging findings in intrauterine growth retardation
I. Çam1, Y. Anik1, E. Çaliskan1, S. Çaglayangil1, A. Yalniz1, T. Agirlar1,
G. Anik Ilhan2, A. Demirci1; 1Kocaeli/TR, 2Istanbul/TR (
[email protected])
Purpose: To investigate diffusion-weighted MR imaging for the diagnosis of
placenta in patients with IUGR diagnosis.
Methods
and Materials: The study included a total of 70 patients; 32 patients
with intrauterine growth restriction, diagnosed via US-Doppler, remaining were
non IUGR fetus. All patients were evaluated with diffusion MRI at 3 T MRI unit.
ROI values of b0, b1000 and ADC maps applied to the placenta were obtained.
The findings were compared with and without the diagnosis of IUGR. In
addition, after birth, two groups' prenatal MRI measurements were correlated
with birth weights.
Results
ADC values calculated from b0 and b1000 signal intensity values
measured in the placenta in cases of IUGR were significantly decreased than
those without IUGR. IUGR infants' birth weights were significantly lower than
those without IUGR. There were significant correlations among prenatal and
birth weight with the diffusion MRI parameters.
Conclusion
Placental diffusion MRI examination can provide an important
contribution to the diagnosis of IUGR cases.
B-0749 11:42
3D ultrasound of the femoro-patellar articulation in newborns
E. Stranzinger, A. Bähler, J.T. Heverhagen, K. Ziebarth, H. Kohlhof; Berne/CH
(
[email protected])
Purpose: To establish a 3D ultrasound screening method of femoro-patellar
dysplasia in newborns.
Methods
and Materials: From 2012 to 2013, we prospectively imaged 160
consecutive femoropatellar joints in 80 newborns from the 36 th to 6 1 st
gestational week that underwent a hip sonography (Graf) and presented with a
type I hip. A paediatric radiologist performed the 3D ultrasound of the femoro-
patellar joint in 30° flexion of the knee. Axial, coronal and sagittal reformats
were used to standardise a reconstructed axial plane through the femoral
condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio
of the trochlea and the shape of the patella (Wiberg) were evaluated.
Results
All 3D exams were diagnostic and feasible for reconstructions in a
standardised axial plane. The mean trochlea angle was 149.1° with ad STD of
4.9°. There was no statistical difference between boys and girls. The lateral to
medial facet ratio of the trochlea ratio was 1.3 with a STD of 0.22. Wiberg type
I patella was found in 95% of the babies and type II in 5%.
Conclusion
3D ultrasound is a reliable technique to image the cartilaginous
femoro-patellar joint in newborns. The shape of the femoro-patellar articulation
in newborns is already preformed in its adult form, which justifies this screening
Method
for femoro-patellar dysplasia. Performing a 3D ultrasound with
standardised reconstructions of the axial plane allows sonographic
measurements to be made. This may have the benefit of lower operator
dependency.
B-0750 11:51
Ultrasound and elastographic evaluation of the lower urinary tract in
patients with hypospadia
C. Bruno, A. Bucci, R. Pozzi-Mucelli; Verona/IT (
[email protected])
Purpose: To determine whether significant differences exist between patients
with hypospadia and normal subjects at conventional ultrasound (US) and
elastography.
Methods
and Materials: 17 male children (age: 5-10 years) with mid-penile or
anterior penile hypospadia and 11 age-matched normal subjects were enrolled.
The sagittal diameter of the corpus spongiosum, the sagittal and the
transversal diameters of the right corpus cavernosum and the angle between
the tangents to the medial surface of the two corpora cavernosa were
measured on a transversal US scan on the ventral surface of the proximal
penis. The length of the bladder neck and the thickness of the detrusor muscle
were also assessed. Real-time sonoelastography of the corpus spongiosum
was performed on a longitudinal scan at the ventral surface of the proximal
penis; a semi-quantitative 3-point sc ale (1 = more, 3 = less elastic) was
adopted.
Statistical analysis was performed using the Mann-Whitney U test.
Results
The patients with hypospadia with respect to the normal subjects had
lower sagittal and transversal diam eters of the right corpus cavernosum, a
wider inter-cavernous angle and a lower elasticity of the corpus spongiosum:
all these differences were highly significant ( P < 0.001). The sagittal diameter
of the corpus spongiosum was lower and the bladder neck longer in the
patients' group ( P
< 0.005), while no significant differences emerged as for the
mean detrusorial thickness.
Conclusion
The patients with hypospadia are significantly different from
normal subjects at US evaluation of the corpora cavernosa, corpus
spongiosum and bladder neck and at elastography of the corpus spongiosum.
10:30 - 12:00 Room P
Contrast Media
SS 1306
Safety issues
Moderators:
G. Heinz-Peer; St. Pölten/AT
Y.W. Nielsen; Copenhagen/DK
B-0751 10:30
Prediction of chronic kidney disease as described in contrast-induced
nephropathy prevention guidelines after contrast enhanced computed
tomography: a cohort of 1000 patients
S.I. Moos, G. Nagan, R.S. de Weijert, D.N.H. van Vemde, J. Stoker, S. Bipat;
Amsterdam/NL (
[email protected])
Purpose: Assessment of accuracy of predicting chronic kidney disease (CKD)
in patients undergoing CECT.
Methods
and Materials: Risk factors mentioned in CIN prevention guidelines
were assessed: diabetes mellitus (DM), history of urologic/nephrologic disease,
nephrotoxic medication, cardiovascular disease, congestive heart failure,
hypertension, anaemia, malignancy and kidney function (estimated glomerular
filtration rate (eGFR)). Association between combinations of risk factors and
CKD (eGFR < 60 ml/min or < 45 ml/min) were studied by Chi
2 test. False-
positives (FP) and false-negatives (F N) were presented. We studied a
combination of: 1) all risk factors, 2) DM, history of urologic/nephrologic
disease, hypertension, age > 60 years; 3) DM, history of urologic/nephrologic
disease, nephrotoxic medication.
Results
998 patients, mean age 59.93 ±13.57 years.115 patients had eGFR
< 60 ml/min and 31 < 45 ml/min. Combination 1 identified 816 patients: 108
with eGFR < 60 ml/min (FN 7/FP 708/Odds-ratio 3.814) and all with eGFR
< 45 ml/min (FP 785). Combination 2 identified 745 patients: 108 with eGFR
< 60 ml/min (FN 7/FP 637/Odds-ratio 5.956) and all with eGFR < 45 ml/min (FP
714)). Combination 3 identified 561 patients, 89 with eGFR < 60 ml/min (FN
26/FP 472/Odds-ratio 2.981) and all with eGFR 75
years/anaemia). All associations between eGFR and combinations were
significant (p-values < 0.01).
Conclusion
Because of the proportion of FP, a combination of all risk factors
is not accurate in predicting CKD. A less elaborate model seems more
accurate and might also be more cost-effective.
S298
BA C D E F G
Sunday
B-0753 10:39
CIN or just fluctuations?
M. Azzouz1, J. Roemsing2, H. Thomsen1; 1Herlev/DK, 2Copenhagen/DK
(
[email protected])
Purpose: To study fluctuations in estimated glomerular filtration rate (eGFR) in
relation to contrast medium (CM)-enhanced magnetic resonance imaging
(MRI) and computed tomography (CT) compared to control groups in
outpatients.
Methods
and Materials: eGFR was determined right before the imaging
procedure and three days later at the department or at the patient's home. The
iodine-based and gadolinium-based contrast media were the same as used for
all other examinations at the department.
Results
A total of 716 patients completed the study. There was a statistically
significant, but not clinically relevant rise in eGFR after three days in all four
groups. The average eGFR variation was 4.8 ml/min/1.73m
2. There were large
variations in eGFR between the two measurements in 41% of the patients as
they had a change greater than ± 10 ml/min/1.73m2. Only three patients
fulfilled the contrast-induced nephropathy (CIN) requirement when the
definition s-creatinine 44 8mol/L was used.
Conclusion
eGFR in outpatients undergoing MRI or CT did vary
independently of whether the patient received contrast or not. The findings
probably reflect the natural variations in s-creatinine levels. This should be
taken into consideration when CIN is studied. The problem of CIN seems to be
overestimated.
Author Disclosures:
M. Azzouz: Equipment Support Recipient; Nova Biomedical sponsored the
StatSensor Creatinine meter. J. Roemsing: Equipment Support Recipient;
Nova Biomedical sponsored the StatSensor Creatinine meter. H. Thomsen:
Equipment Support Recipient; Nova Biomedical sponsored the StatSensor
Creatinine meter.
B-0754 10:48
Efficacy of questionnaire prior to contrast CT in predicting renal
impairment for patients older than sixty years of age
Y. Li, K.K.-P. Lau; Melbourne/AU (
[email protected])
Purpose: Contrast-induced-nephropathy (CIN) is a preventable condition. Pre-
CT questionnaire was routinely used only on patients less than 60 years-of-age
to reduce the incidence of CIN. Patients over 60 years-of-age commonly
require pre-CT renal function tests. The aim of this prospective study was to
assess the efficacy of pre-CT questionnaire in patients over 60 years-of-age in
predicting renal impairment.
Methods
and Materials: All consecutive outpatients older than 60-years-of-
age, who underwent contrast enhanced CT over 9 months period, were
required to complete questionnaires cont aining 14 risk factors for CIN.
Estimated-glomerulofiltration-rate (eGFR) and serum creatinine level were
obtained and results were compared.
Results
A total of 922 patients were included (mean age: 71). 36.12%
patients answered no risk factor. 37.2% patients had 1 risk factor and 26.68%
had 2 risk factors. All groups had similar patient demographics and disease
prevalence. 103 (11.17%) patients had eGFR < 60, including 1.63% patients
with eGFR < 40. The questionnaire demonstrated an overall negative
predictive value (NPV) of 96.7%. NPV was 97.6%, 97.5% and 91.7% for
patients between 60-69, 70-79 and 80 years-of-age. NPV was 86.9% and
80.9% respectively when there were 1 and 2 risk factors. Relationship
between number of risk factors and severity of renal impairment was weak
(correlation coefficient r=0.2393, p-value 0.0149). Kidney disease and
myeloma as risk factors had relatively higher correlation with renal impairment.
Conclusion
Negative pre-CT questionnaire is shown to be an effective
screening tool for renal impairment in patients over 60 years-of-age, hence,
reduces the need and cost of performing renal function tests.
B-0755 10:57
Can a structured questionnaire identify patients with reduced renal
function?
J. Roemsing
1, M. Azzouz2, H. Thomsen2; 1Copenhagen/DK, 2Herlev/DK
(
[email protected])
Purpose: To evaluate the value of a structured questionnaire in identifying
outpatients with renal dysfunction before MRI or CT examinations.
Methods
and Materials: All patients completed a questionnaire with five risk
factors indicating renal dysfunction: renal disease, renal surgery, hypertension,
gout and diabetes. S-creatinine determined by point of care (POC) technique
and estimated glomerular filtration (eGFR) rate was calculated using CKD-EPI
equation.
Results
A total of 1467 patients were enrolled. Thirty-four (2%) patients had
an eGFR < 30 ml/min/1.73m
2 and 123 (8%) had an eGFR < 45 ml/min/1.73m2.
Among 55% patients reporting at least one risk factor, 30 (4%) had an
eGFR< 30 ml/min/1.73m2 and 105 (13%) had an
eGFR< 45 ml/min/1.73m2.Among 651 patients not reporting a risk factor, 4
(0.6%) had an eGFR < 30 ml/min/1.73m2 and 18 (3%) had an
eGFR 70 years, and 12 of the 18
patients were > 70 years. Among 81 patients > 80 years, 33% had an
eGFR 70 years.
Conclusion
The questionnaire used in patients 70 years identified all patients with an eGFR between 30-
45 ml/min/1.73m2 except 0.4%.
Author Disclosures:
J. Roemsing: Equipment Support Recipient; Nova Biomedical sponsored the
StatSensor Creatinine meter. M. Azzouz: Equipment Support Recipient; Nova
Biomedical sponsored the Statsensor Creatinine meter. H. Thomsen:
Equipment Support Recipient; Nova Biomedical sponsored the StatSensor
Creatinine meter.
B-0756 11:06
Contrast induced nephropathy prevention guidelines: should we
determine eGFR in all patients or in a selected group of patients based on
risk profile?
S.I. Moos, R.S. de Weijert, G. Nagan, J. Stoker, S. Bipat; Amsterdam/NL
(
[email protected])
Purpose: To assess whether pre-selection by assessment of risk factors in
patients before determining eGFR is more cost-effective compared to a
strategy where eGFR is determined in all patients undergoing CECT.
Methods
and Materials: Patients were interviewed to assess risk factors and
costs. In our institute eGFR is evaluated in all patients, we considered a
tenability of 12 months for eGFR, eGFR was available in all patients. For the
pre-selection strategy we extrapolated dat a by assuming equal distribution of
patient characteristics between both strategies.
Results
We included 1,001 patients, mean age 59.93 ± 13.57 years. Strategy
with eGFR in all patients: the number of patients in which eGFR was
determined before CECT was 645/1,001. In this population 49 patients paid an
extra visit to the hospital, 11 patients had to take a leaf of absence from work
for this visit. The total cost of this strategy was: 5766.05 euro. In the other 356
patients the eGFR was already known.Pre-selection strategy: 807/1,001
patients had risk factors, and eGFR determination was indicated. Based on the
equal distribution, we assumed that 44 patients would have visited the hospital
for eGFR determination, 10 would have taken a leaf of absence. Total cost,
inclusive eGFR determination in 807 patients would be: 6565.44 euro. No
patients with an eGFR < 45 ml/min or eGFR 1 other risk factor would have been missed by this strategy.
Conclusion
Determination of eGFR in all patients seems cost-effective when
tenability for eGFR is applied.
B-0757 11:15
NSsaFe study: observational study on the incidence of nephrogenic
systemic fibrosis (NSF) in renal impaired patients following gadoteric
acid administration
D. Verdries, C. Brussaard, L. Pipeleers, K. Francois, J. de Mey; Brussels/BE
(
[email protected])
Purpose: To prospectively estimate the incidence of NSF in patients with
moderate to severe renal impairment after administration of gadoteric acid.
Methods
and Materials: A worldwide post-marketing study being conducted to
collect safety data in 1,000 patients (adults and children) with moderate to
severe and end stage renal impairment, scheduled to undergo a routine
contrast-enhanced magnetic resonance imaging using gadoteric acid
(DOTAREM®). Risk factors at inclusion, indications for MRI and occurrence of
adverse events are recorded for each patient. Three follow-up visits are
performed between 3 and 27 months after MRI in order to detect any
occurrence of NSF.
Results
As of August 29, 2013, the cut-off date for the interim safety analysis,
the study included 309 patients (mean age: 69.6 years (range: 21-92); male,
63.1%). Mean eGFR at inclusion was 35.8 ml/min/1.73m
2 (range: 4.0-59.1)
including 63.4% of moderate, 18.4% of severe, 14.9% of end stage renal
insufficiency or dialysis and 3.2% of kidney transplanted patients. The first
follow-up visit (between 3 and 12 months after MRI) was done for 128 patients,
the second follow-up visit (between 13 and 21 months after MRI) was done for
42 patients. Only 2 patients (0.6%) had serious adverse events not related to
gadoteric acid. No NSF occurred.
Conclusion
This interim safety analysis confirms the very good safety profile
of gadoteric acid in renal impaired patients.
S299
BA C D E F G
Sunday
B-0758 11:24
Tolerability and diagnostic effectiveness of gadoteric acid (Gd-DOTA):
use in daily routine and in patients with diminished kidney function
M. Maurer1, M. Wolf2, O. Heine3; 1Berlin/DE, 2Püttlingen/DE,
3Sulzbach/DE (
[email protected])
Purpose: To investigate the tolerability and diagnostic effectiveness of Gd-
DOTA (Dotarem®, Guerbet, Roissy, France) in routine clinical use and in
patients with impaired kidney function.
Methods
and Materials: Between January 2011 and July 2013, 32,286
patients (44.7% male, 55.3% female, mean age 52.0± 17.0 years) underwent
contrast-enhanced MRI (Gd-DOTA, mean volume 15.7 ml) in 43 German
centers, including neurological examinations (48.7%), musculoskeletal
examinations (30.7%) and examinations of the internal organs (13.2%). 26.8%
of patients were at-risk patients including patients with allergies (16.7%) and a
previous reaction to contrast media (0.4%). In 854 patients (2.6%), eGFR was
< 90 ml per minute. Imaging quality (assessed on a 5-point scale:
excellent/good/moderate/poor/very poor) and diagnostic effectiveness were
assessed for each individual examination. Adverse reactions and serious
adverse reactions were documented.
Results
Adverse reactions occurred in 110 out of 32,286 patients (0.3%),
generally involving gastrointestinal disorders (0.2%) or skin and subcutaneous
tissue disorders (0.1%). In 5 patients (0.015%), the adverse reactions were
serious. All patients with adverse reactions recovered after the examination.
No adverse reactions were observed in the 854 patients with an eGFR < 90 ml
per minute. A diagnosis was possible in 99.9% of all examinations. Image
quality was rated excellent or good in 98.5% of all examinations, moderate in
1.4% and poor in 0.1%.
Conclusion
In routine clinical use, Gd-DOTA has proved to be a safe contrast
medium, including in patients with an eGFR < 90 ml per minute, which enables
MRI examinations to be performed with high diagnostic effectiveness.
Author Disclosures:
M. Maurer: Consultant; Guerbet GmbH. O. Heine: Employee; Guerbet GmbH.
B-0759 11:33
SECURE study: observational post-marketing study on the safety of
gadoteric acid
M. Hackenbroch, D. Maintz;
Cologne/DE (
[email protected])
Purpose: To prospectively assess the safety profile of gadoteric acid and the
overall incidence of nephrogenic systemic fibrosis (NSF).
Methods
and Materials: An ongoing worldwide post-marketing study (PMS) is
conducted to collect safety data in 40,000 patients (adults and children) with or
without renal insufficiency, scheduled to undergo a routine contrast-enhanced
magnetic resonance (MR) imaging using gadoteric acid (Dotarem®). Risk
factors at inclusion, indications for MR imaging, conditions of the contrast
Material
administration and occurrence of adverse events are recorded. For
any patient identified with renal impairment at the time of inclusion (i.e.,
estimated creatinine clearance or estimated glomerular filtration rate
< 60 mL/min/1.73 m²), a follow-up is performed after at least 3 months in order
to detect any suspicion or occurrence of NSF.
Results
The latest interim safety analysis of this ongoing PMS included data
on 29,689 patients (mean age: 50 years; range: 0-98 years; female: 53.4%).
MR examinations were mainly performed to image the central nervous system
(55.1%). The main risk factors were renal insufficiency (12.7%) and
hypertension (11.8%). Moderate to severe impaired renal function was
reported in 552 patients (1.9%). Among them, 391 (70.8%) were reported
without suspicion of NSF during the 3-month follow-up. For the remaining
patients (29.2%), the follow-up evaluation was not yet reported at the time of
data analysis. Twenty-eight patients ( < 0.1%) had at least one adverse event
(mainly nausea, urticaria, vomiting, fever and multiorgan failure syndrome).
Conclusion
This interim safety analysis already confirms the very good safety
profile of gadoteric acid.
Author Disclosures:
M. Hackenbroch: Grant Recipient; Travel grant.
B-0760 11:42
Effect of contrast agent temperature on aortic enhancement profile in CT
angiography: a phantom study
M. Benz1, J. Froehlich2, U. Würtemberger1, G. Stadelmann1, J. Janetzki1,
U. von Baer3, G.M. Bongartz1, S. Schindera1; 1Basle/CH, 2Zurich/CH,
3Ulm/DE (
[email protected])
Purpose: To analyse the effect of iodinated contrast agent temperature on
aortic enhancement characteristics in CT-angiography.
Methods
and Materials: A custom made physiologic flow-phantom was
designed to simulate the cardiovascular system in a medium-sized patient.
70 ml of two contrast agents (agent A, iobitridol, Xenetix 300, Guerbet and
agent B, iomeprol, Iomeron 400, Bracco) were administered at rates of 4 and
6 ml/s (CT-Motion, Ulrich Medical) at three different temperatures (22 °C,
30 °C, and 37 °C). At 37 °C, the viscosity of agent A and agent B are 6.0
mPa.s and 12.6 mPa.s. The phantom was scanned with 100 kVp and 200 mAs
(Somatom Definition Flash, Siemens). Dynamic CT-images were acquired after
contrast agent injection with 1 image per second for 50 seconds. Peak aortic
enhancement (PAE) and the duration of aortic enhancement 200 HU were
recorded.
Results
For agent A the PAE at 22 °C, 30 °C and 37 °C measured 237, 231,
and 235 HU, at a flow rate of 4 ml/s, and 297, 320, and 321 HU at a rate of
6 ml/s, respectively. Corresponding PAE measurements for agent B were 308,
312, and 310 HU, at a flow rate of 4 ml/s, and 422, 418, and 424 HU at a flow
rate of 6 ml/s, respectively. The duration of aortic enhancement 200 HU was
dependent on iodine concentration (9 to 10s for agent A, and 12 to 14s for
agent B), but independent of contrast media temperature.
Conclusion
CT contrast agent temperature does not impact the aortic
enhancement profile in CT-angiography.
Author Disclosures:
J. Froehlich: Employee; Guerbet AG. U. von Baer: Employee; Ulrich
Medical. S. Schindera: Equipment Support Recipient; Ulrich Medical.
S300
BA C D E F G
S301
BA C D E F G
Monday
10:30 - 12:00 Room B
Abdominal Viscera
SS 1701
Functional MR of the liver
Moderators:
B.I. Choi; Seoul/KR
H.J. Michaely; Mannheim/DE
B-0761 10:30
Non-invasive differentiation between simple steatosis and steatohepatitis
using gadoxetic acid-enhanced MRI in patients with non-alcoholic fatty
liver disease: a feasibility study
N. Bastati-Huber; Vienna/AT (
[email protected])
Purpose: To determine whether gadoxetic acid-enhanced MRI can be used to
distinguish between simple steatosis (S IS) and non-alcoholic steatohepatitis
(NASH) in non-alcoholic fatty liver disease (NAFLD) patients defined according
to the Steatosis Activity Scoring system (SAF).
Methods
and Materials: This was a retrospective study of gadoxetic acid-
enhanced 3-Tesla MRI performed on 81 consecutive patients with suspected
NAFLD [45 (56%) males (mean age 56y, range: 25-78)]. Patients were
classified as SIS or NASH using the SAF score based on the semiquatitative
scoring of steatosis, activity and liver fibrosis. The MR images were analysed
using the relative liver enhancement measured as the ratio of signal intensities
of the liver parenchyma before and 20 minutes after intravenous administration
of gadoxetic acid. Univariate and multivariate regression analyses were applied
to identify variables associated with relative enhancement measurements, and
the performance of relative enhancement values was assessed for the
differentiation between SIS and NASH using the area under the receiver
operating characteristic curve (AUC) analysis.
Results
Testing the relationship between enhancement measurements and
histology, relative enhancement values correlated strongly with lobular
inflammation (r=-0.59, p= < 0.001), ballooning (r=-0.44, p= < 0.001), and fibrosis
(r=-0.59, p= < 0.001), but not with steatosis (r=-0.15, p=0.15). In multivariate
analysis, all three histological parameters were independently associated with
the relative enhancement. The measurements performed well for the
differentiation between SIS and NASH, with an AUC of 0.85, [cutoff=1.24,
(Sesitivity=97.1%, Specificity =63%)].
Conclusion
Gadoxetic acid-enhanced MRI may be used as a non-invasive
diagnostic tool to distinguish between SIS and NASH in NAFLD patients.
B-0762 10:39
MRI-proton spectroscopy in diognosis of NADFL
M. Sharia, G. Shirjaev; Moscow/RU (
[email protected])
Purpose: Purpose of our study is to determine the possibilities of MRS for the
diagnosis of fatty liver and monitoring the effectiveness of treatment.
Methods
and Materials: We investigated 85 patients (44 men, 41 women),
mean age was 48 ± 11 years. The studied group consisted of two sub-groups:
healthy volunteers (15 men) and patients with non-alcoholic fatty liver disease,
diagnosed according to clinical examination (60 patients). In the group of
patients MRS was performed twice: before treatment and six months after it
began. The study was conducted on MRI scanner with magnetic field strength
of 3 T, using a 32-channel coil. According these images the navigation of
spectroscopic voxel (single voxel MRS, voxel size 20x20x20 mm) was done in
the fifth segment of the liver. We used the protocol: TE - 50 ms, TR - 2000 ms,
the spectral range - 2000, Samples - 1024. Calculation was done for each
patient according to the formula of lipid concentration.s. (Lip) / S (H20) × 100.
Results
In the group of patients lipid concentration in 45 cases was measured
and draws up to more than 10%. the diagnosis of NAFLD was eliminated. At
the second examination (as a result of lipid-lowering therapy and diet) in 34
patients were detected reduction in the concentration of fat to normal values.
Conclusion
MRS could be used as an additi onal criterion for the diagnosis
and assessment of treatment of NAFLD, especially in cases when carrying out
liver biopsy is not possible.
B-0763 10:48
Association between central obesity and liver iron: a non-invasive
assessment in general population by magnetic resonance imaging
A. Radmard, A. Abrishami, M. Gerami Seresht, M. Dadgostar, A. Yoonessi,
A. Hashemi Taheri, H. Poustchi, S. Merat, R. Malekzadeh; Tehran/IR
(
[email protected])
Purpose: Existing evidence suggests an altered iron metabolism in obesity.
Published data evaluating association of he patic iron with obesity are lacking.
We aimed to investigate whether central obesity is independently associated
with liver iron content in general population using non-invasive assessment by
MRI.
Methods
and Materials: The study was carried out on 202 subjects randomly
selected from general population, aged 50-77 years, who underwent
abdominal MRI (1.5 T) including multiechoT2*-weighted sequence of liver.
Quantitative T2* maps of entire cross-sectional area of liver was calculated on
a pixel-by-pixel basis using a semi-automated software to measure mean T2*
of whole liver. Visceral and subcutaneous fat areas were measured by two
examiners in axial T1-weighted images at the level of umbilicus.
Results
There was no significant difference in mean values of T2* between
obese (BMI > 30 kg/m
2) and non-obese (BMI 30 kg/m2) subjects. After
controlling for other covariates including age, BMI, ferritin, hemoglobin, FBS,
HBA1c and steatosis no statistically significant association was detected
between liver T2* values and visceral and subcutaneous fat areas in men and
women. Likewise, the association between liver T2* values and ratio of visceral
to subcutaneous fat was not demonstrated in multivariable analysis.
Conclusion
Central obesity indices are not correlated with estimated liver iron
content in MRI. This study could not support the hypothesis of probable hepatic
iron release due to obesity-related biomarkers. The relationship, if it exists,
should be investigated in the future studies.
B-0764 10:57
The feasibility of texture analysis using susceptibility-weighted magnetic
resonance imaging in detecting patients with liver cirrhosis
D.S. Feier1, T. Knogler2, M.E. Mayerhoefer2, C. Balassy2, A. Ba-Ssalamah2;
1Cluj-Napoca/RO, 2Vienna/AT (
[email protected])
Purpose: To establish the feasibility of textural features of liver parenchyma
obtained on susceptibility weighted magnetic resonance imaging (SWI MRI)
which will enable the detection of liver cirrhosis in patients with diffuse chronic
liver diseases (CLD).
Methods
and Materials: Sixty-five patients (mean age, 51.65 years; 60%
males) with CLD and histologically proven liver fibrosis (evaluated according to
the Metavir scoring) were included in a retrospective manner and grouped in
patients with (F4 Metavir, n=27, 42%) and without (F0-F3 Metavir, n=38, 58%)
liver cirrhosis. All patients underwent 2D multislice breath-hold SWI sequence
on a 3 T MRI unit and the imagines were used for texture analysis. Texture
features derived from the grey-level histogram, the co-occurrence matrix, the
run-length matrix, the absolute gradient, the autoregressive model, and the
wavelet transform were calculated for the ROIs. Fisher coefficients were
calculated to determine which texture features were best suited for
distinguishing between no-cirrhosis and ci rrhotic liver tissue. Based on the ten
best-suited texture features, linear discriminant analysis was performed, and a
k-nearest neighbor (k-NN) algorithm was used for disease classification. The
classification accuracy, sensitivity and specificity were used as primary and
secondary outcome measures.
Results
Six out of ten texture features selected on the basis of Fisher
coefficients were derived from grey-l evel histogram. Of the 65 patients
included, 62 (95.38%) were classified correctly by k-NN. Sensitivity was 96.3%
and specificity was 94.7%.
Conclusion
Texture features extracted from the grey-level histogram are
feasible to correctly identify cirrhotic changes in liver parenchyma of patients
with CLD.
B-0765 11:06
Unenhanced MRI of the liver: morphology assessment on diffusion-
weighted images has additional diagnostic value to quantitative apparent
diffusion coefficient (ADC) measurements
P.A.T. Baltzer
1, M. Dietzel2, W.A. Kaiser3; 1Vienna/AT, 2Erlangen/DE,
3Jena/DE
Purpose: Diffusion-weighted imaging (DWI) is regularly applied as an
additional contrast for detection and charac terisation of focal liver lesions (FLL)
in MRI of the liver. Besides quantitative information by means of apparent
diffusion coefficient (ADC) measurements, DWI images do also provide
morphological information. We investigated whether diagnostic accuracy for
differentiation of FLL could be improved by adding visual interpretation of DWI
images to quantitative ADC measurements.
Methods
and Materials: Consecutive patients with suspected liver metastases
without prior treatment were examined using breathhold EPI-DWI (TR/TE:
2100/62 ms, 2 b values). A blinded radiologist ( > 8years MRI experience)
assessed morphological criteria such as lesion border (smooth vs irregular)
and internal structure (homogeneous vs heterogeneous) on DWI images.
Additionally, ADC values were measured by means of regions of interest. The
radiologist assigned a diagnostic rating on a 5-point confidence scale (1:
definitive benign to 5: de finitive malignant). Diagnostic accuracy of ADC and
qualitative assessment were compared by means of ROC analysis.
Results
Eighty-nine FLL were detected using DWI (50 malignant and 39
benign). Diagnostic accuracy of ADC-values was significantly lower (0.895,
95% CI 0.812-0.950) as compared to additive assessment of morphological
criteria on DWI images (0.941, 95% CI 0.870-0.980; P < 0.05)
S302
BA C D E F G
Monday
Conclusion
In unenhanced MRI of the liver, diagnostic accuracy of DWI
interpretation could be improved compared to quantitative ADC measurements
by integration of morphological criteria on DWI images as interpreted by an
experienced radiologist.
B-0766 11:15
Steatosis quantification: comparison MRI vs histology in rat model using
total intrahepatic triglycerides as reference
L.-M. Leiber, J. Boursier, S. Michalak, V. Roullier, L. Fizanne, J. Roux,
Y. Gallois, C. Aube; Angers/FR (
[email protected])
Purpose: To evaluate the steatosis quantification by MRI in a murine model
and compare it to histological quantifi cations using semi quantitative visual
analysis or automated surface analysis.
Methods
and Materials: Eleven groups of two rats undergo a choline
methionine deficient diet. An 1.5 T MRI was carried out at day 0, 2, 4, 5, 6, 7, 8
and week 2, 3, 4, 5. Using a phased-array surface coil, an EG T1 in and out
phase multi echo sequence, without cardiac or respiratory synchronisation,
was performed. Steatosis was calculated with the 3 echo method. Histological
quantifications were performed both by visual evaluation of the percentage of
fatty hepatocytes and by an automated measurement of the steatosis area
(AOS). The reference was the total intrahepatic triglycerides (TIT)
concentration.
Results
A steatosis without inflammation was obtained with an amount
proportional to the duration of the diet. Correlations with TIT were better for
MRI than for AOS and for histological quantification (RSpearman respectively
r=0.897 r=0.889, r=0.753 p < 0.0001). Analysis of intra-class correlation
coefficient was better for MRI than for AOS which tends to overestimate the
steatosis (ICCC=0.889 versus ICCC=0.629). For visual histological
quantification ICCC was low (0.280). In multivariate analysis, only MRI was
identified as independent predictor of liver TIT.
Conclusion
MRI is reliable, easy, fast and superior to histological techniques
for the assessment of hepatic steatosis in a murine model.
B-0767 11:24
The effect of echo times on the accuracy of susceptibility weighted
magnetic resonance imaging in staging liver fibrosis
C. Balassy1, D. Feier2, F. Wrba1, S. Witoszynskyj1, A. Ba-Ssalamah1;
1Vienna/AT, 2Cluj-Napoca/RO (
[email protected])
Purpose: To assess the effect of echo-sampling on the accuracy of magnetic
resonance (MR) susceptibility-weighted imaging (SWI) to detect and stage liver
fibrosis in patients with chronic liver diseases (CLD), using histology as
reference.
Methods
and Materials: Sixty-eight patients were included. SWI was
performed with two different echo times (TE), 2.5 ms and 10 ms. Signal
intensity (SI) of the liver and spinal muscle was measured and liver-to-muscle
signal intensity ratios were calculated . Diagnostic performance of both LMR in
staging liver fibrosis was assessed using sensitivity (Se%), specificity (Sp%)
and area under receiver operating characteristics (AUROC) analysis.
Results
Histology resulted F0 (n=13), F1 (n=6), F2 (n=8), F3 (n=12), F4
(n=28). Both 2.5TE LMR and 10TE LMR correlated strongly with liver fibrosis
(r=-0.74, p < 0.0001 and r=-0.84, p < 0.0001, respectively). Diagnostic
performance of LMR at 2.5 TE was very good, with an AUROC of 0.85
(Se=90.7%, Sp=76.9%) for stages F1, 0.88 (Se=95.8%, Sp=73.7%) for
stages F2, 0.90 (Se=92.5%, Sp=74.1%) for stages F3 and 0.89 (Se=85.7%,
Sp=82.1%) for liver cirrhosis diagnosis (F4). Diagnostic accuracy improved
when the TE was increased to 10 ms, reaching an AUROC of 0.96 (Se=96.3%,
Sp=100%) for stages F1, 0.95 (Se=100%, Sp=78.9%) for stages F2, 0.94
(Se=85%, Sp=92.6%) for stages F3 and 0.92 (Se=92.9%, Sp=76.9%) for F4
diagnosis. MecNemar tests revealed a sta tistically significant difference
between the two parameters regarding the diagnosis of early fibrosis (stages
F1, p < 0.0001).
Conclusion
SWI is a promising non-invasive tool to detect and stage liver
fibrosis in CLD patients, having increased accuracy with higher TE values.
B-0768 11:33
DWI of liver lesions: IVIM model with different combination of 11 b values
G. Morana1, G. Scattolin2, R. Zanato2, F. De Leo1; 1Treviso/IT, 2Padova/IT
(
[email protected])
Purpose: Purpose of this study was to investigate diffusion coefficients
evaluated with intravoxel incoherent motion (IVIM) model in liver lesions, in
their different parameters: apparent di ffusion coefficient (ADC), perfusion
fraction (f), diffusion and pseudodiffusion coefficient (D and D*). Moreover, we
tried to calculate the optimal b values to be utilised in their analysis.
Methods
and Materials: Retrospective study of 96 patients undergoing MR
with DWI between June 2011 and September 2012 with diagnosis of HCC
(n=28), colorectal carcinoma metastasis (CCM) (n=24) or FNH (n=44). MR
examinations were performed on a 1.5-T scanner (Siemens_Avanto) and DWI
sequence was EPI (TR/TE=4361/54 ms) with 11 b-values. Using MatLab, the
estimations of D, D* e f were carried out for different combination of b-
values:C1,C2,C3. Statistics Analysis: scatter plot; 2 sample t test; Kruskal-
Wallis test.
Results
ADC and D values were not significantly different between lesions. D*
and f were not significantly different between HCC (160x10-3 mm2/sec; 22%
respectively) and FNH (114x10-3 mm2/sec; 18%), whereas were significantly
higher than in CCM (81x10-3 mm2/sec;8%) (p < 0.05).͒With lesser b values
(C2,C3) D* shows a significant (p < 0.05) decrease in HCC (88x10-3 mm2/sec)
while does not show significantly decrease in FNH and in CCM, thus loosing
the difference between the above groups. f does not show a significantly
decrease in the above groups,thus maintaining the statistical difference. D
does not change. f in background liver parenchyma were not significantly
different between HCC (21%), FNH (22%) and CCM (20%).
Conclusion
IVIM data are dependent of b values being utilised. The D* and f
values are useful for the characterisation of hyper (HCC; FNH) and
hypovascular lesions (CCM). A standardisation of techniques is necessary in
order to compare results between different studies.
B-0769 11:42
Accuracy of ultrasound in the assessment of liver fat: an MRI correlation
study
P.-O. Behrndt, M. Habes, H. Völzke, J. Mayerle, K. Hegenscheid, J.-P. Kühn;
Greifswald/DE (
[email protected])
Purpose: To investigate the accuracy of ultrasound in the assessment of liver
fat using chemical shift encoded confounder corrected magnetic resonance
imaging (MRI) as standard of reference.
Methods
and Materials: In the context of a population-based screening, 1122
volunteers, 558 women, 564 men with a mean age of 53.0 ±13.7 years,
underwent liver MRI (1.5 T, Avanto; Siemens Healthcare) and ultrasound (Vivid
I; GE-Healthcare; 3.6Mhz transducer). Liver ultrasound was performed by
certified observers evaluating the presence of liver steatosis subjectively. In
addition, percentage of liver fat content was assessed using a R2*-,T1-,multi-
peak fat-corrected chemical shift MRI. Sensitivity, specificity and area under
the curve (AUC) were calculated for ultrasound compared to MRI as reference
for all subjects and for subjects with ranges of the liver fat content separately.
Results
With MRI frequency of liver steatosis was 39.5%(443 subjects) in the
general population: 304 (69%) subjects with mild, 121 (27%) and 18 (4%)
subjects with moderate and high liver fat content, respectively. In contrast, with
ultrasound frequency of liver steatosis was lower 32% (359 subjects). All over
sensitivity, specificity and AUC for the assessment of liver steatosis by
ultrasound were 0.65, 0.90, and 0.77, respectively. While the specificity of
ultrasound was not affected by liver fat content (mild, moderate, high fat
content: 0.89, 0.89, 0.90) the sensitivity (0.54, 0.88, 0.94) and AUC (0.71, 0.89,
0.92) increased with the amount of liver fat.
Conclusion
Ultrasound is a moderate approach to assess liver fat. The
weakness of ultrasound in the assessment of liver fat, especially in subjects
with mild steatosis should be considered.
B-0770 11:51
Assessing liver function by liver enhancement during the hepatobiliary
phase with Gd-EOB-DTPA-enhanced MRI at 3 Tesla
N. Verloh, M. Haimerl, F. Zeman, M. Schlabeck, C. Stroszczynski, C. Fellner,
P. Wiggermann; Regensburg/DE (
[email protected])
Purpose: The purpose of this study was to evaluate the usefulness of Gd-
EOB-DTPA-enhanced 3 T MRI to determine the hepatic functional reserve
expressed by the MELD score.
Methods
and Materials: 150 consecutive patients underwent contrast-
enhanced MRI with liver specific contrast media at 3 T. Patients were
subdivided into two groups: 121 patients with a MELD score lower than or
equal to 10 (normal liver function, NLF) and 29 patients with a MELD Score
higher than 10 (impaired liver function, ILF). T1-weighted volume interpolated
breathhold examination (VIBE) sequences with fat suppression were acquired
before and 20 minutes after contrast injection. Relative enhancement (RE)
between plain signal intensity and contrast-enhanced signal intensity was
calculated and was used to determine and compare Gd-EOB-DTPA uptake
into the liver parenchyma for patients with different MELD scores.
Results
RE differed significantly (p 0.001) between patients with normal
liver function (NLF, MELD score 10) (87.20% ± 29.50%) and patients with
impaired liver function (ILF, MELD score > 10) (45.44% ± 26.52%). Cut-off
values regarding the RE to differentiate NLF from ILF was 47.7% (AUC: 0.87).
This cut-off value showed a sensitivity of 82.8% and a specificity of 92.7%
regarding the differentiation of the analysed groups.
Conclusion
Gd-EOB-DTPA uptake into hepatocytes is strongly affected by
liver function. In conclusion, Gd-EOB-DTPA-enhanced MRI and assessment of
relative enhancement during the HBP may serve as a useful image-based test
in liver imaging for determining regional and global liver function.
S303
BA C D E F G
Monday
10:30 - 12:00 Room C
Cardiac
SS 1703
Coronary artery imaging with CT
Moderators:
L. Natale; Rome/IT
F. Wolf; Vienna/AT
B-0771 10:30
Effect of reduced x-ray tube voltage, low iodine concentration contrast
medium and iterative reconstruction on image quality and radiation dose
at coronary CT angiography: results of the prospective multicentre
REALISE trial
A.D. McQuiston
1, W.-H. Yin2, U.J. Schoepf1, J.-B. Gao3, P.-L. Li4, K. Sun5,
Z.-F. Wu6, F.G. Meinel1, B. Lu2; 1Charleston, SC/US, 2Beijing/CN,
3Zhengzhou/CN, 4Shenyang/CN, 5Baotou/CN, 6Taiyuan/CN
(
[email protected])
Purpose: To assess the effect of reduced x-ray tube voltage, low iodine
concentration contrast medium and iterative reconstruction on image quality
and radiation dose at coronary CT angiography (CCTA).
Methods
and Materials: 231 consecutive patients with suspected coronary
artery disease were prospectively randomised to one of two dual-source CCTA
protocols: 120-kVp, 370 mgI/mL iopromide or iopamidol, and filtered back
projection (n=116; 44 women; 55.3 ±9.8 years); or 100-kVp, 270-mgI/mL
iodixanol, and iterative reconstruction (n=115; 48 women; 54.2 ±10.4 years).
Attenuation in the ascending aorta and coronary arteries along with image
noise was measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio
(CNR) were calculated. Image quality was scored on a five-point scale for each
coronary segment. Size-specific dose estimates and effective doses were
calculated. Data were compared using Student's t test and <
2 test.
Results
There were no statistically signifi cant differences in mean arterial
attenuation (406.6± 76.7 vs. 410.6 ±67.0 HU, p=0.673), image noise (18.7 ±3.8
vs. 17.9± 3.4 HU; p=0.141), SNR (22.5± 5.4 vs. 23.7 ±6.1; p=0.108), CNR
(37.1±14.7 vs. 38.1 ±15.2; p=0.609) or image quality scores (4.1 ±0.9 vs.
4.0±0.9; p=0.179) between the 120 and 100-kVp protocols. Mean iodine dose
was 26.5% lower (18.3 ±0.5 vs. 24.9 ±0.9 g; p < 0.0001) and mean effective
dose was 34.9% lower (2.3 ±1.0 vs. 3.5 ±1.1 mSv; p < 0.0001) with the 100 kVp
compared with the 120-kVp protocol.
Conclusion
Using low x-ray tube voltage and iterative reconstruction allows
for decreasing the iodine load and effective radiation dose at CCTA while
maintaining image quality.
Author Disclosures:
U.J. Schoepf: Consultant; UJS is a consultant for and / or receives research
support from Bayer, Bracco, GE, Medrad and Siemens. Grant Recipient; GE
Healthcare provided grant support and supplied contrast material for this
study.
B-0772 10:39
Influence of iodinated contrast agents on heart rate variability during CT
angiography of the coronary arteries: a prospectively randomised study
C. Loewe, L. Reider, V. Schöpf, S. Unterhumer, D. Beitzke, F. Wolf,
J. Lammer; Vienna/AT (
[email protected])
Purpose: To assess the influence of different contrast agents on heart rate
variability during CTA of the heart.
Methods
and Materials: 207 patients (95 women) referred for cardiac CTA to
rule out CAD and at a baseline heart rate below 70 were consecutively
enrolled. CTA was performed after randomisation either during administration
of Iodixanol (n=101) or Iomeprol. Patients were divided into three groups
according to their body weight. In all patients within same body weight group
same iodine delivery rate was used. Heart rates were recorded with a mobile
heart rate monitor before, while and after contrast media administration.
Contrast enhancement was evaluated at four predefined anatomical regions.
Results
While both contrast agents raise mean heart rates within 60 seconds
after injection, iomeprol elevates heart rates earlier and to higher levels with a
peak heart rate change of 13 bpm (iodixanol 7 bpm). 33 seconds after start of
contrast administration iomeprol was found to induce significantly higher heart
rate increases when compared to iodixanol. In the group of patients with body
weight between 50 and 100 kg (n=177), differences in heart rates became
significant within 18 seconds after start of contrast injection. There was no
difference in arterial contrast enhancement between the two agents.
Conclusion
Iodixanol showed less influence on heart rate during cardiac CTA
when compared to Iomeprol. The difference of heart rate increase between the
two agents becomes significant after 18 seconds in most of the patients (and
after 33 seconds in all patients).
B-0773 10:48
Hemodynamic significance of coronary stenosis by vessel attenuation
measurement on CT compared with adenosine perfusion MRI
M.A.M. den Dekker, G. Pelgrim, K.G.O. Ike, G. Pundziute,
E.R. van den Heuvel, M. Oudkerk, R. Vliegenthart; Groningen/NL
(
[email protected])
Purpose: Corrected contrast opacification (CCO) calculation is a new
technique based on coronary computed tomography angiography (cCTA) data,
estimating the effect of stenosis on coronary flow. We assessed the
association between CCO and inducible ischemia by adenosine perfusion
magnetic resonance imaging (APMRI).
Methods
and Materials: Sixty cardiac asymptomatic patients with extra-
cardiac arterial disease (mean age 64.4 ±7.7 years;78% male) underwent cCTA
and APMRI. Luminal CT attenuation values (Hounsfield Units) were measured
in coronary arteries from proximal to distal. Additional measurements were
performed in arteries with significant, > 50% lumen stenosis. CCO was
calculated by dividing coronary CT attenuation by descending aorta CT
attenuation at equal level. Decreases in CCO across the coronary artery and
across stenosis were calculated, and compared with presence of inducible
ischemia on APMRI using regression analysis.
Results
In total, 169 coronary stenoses were found. Seven patients had 8
perfusion defects on APMRI, with 11 stenoses in the corresponding coronary
arteries. Baseline characteristics did not differ between patients with and
without perfusion defect. Median CCO for normal coronary arteries was 1.075
[25
th,75th percentile:0.978.1.169] at the origin, and 1.021 [0.876.1.142] at the
distal segment. Difference in CCO across stenosis was significantly larger in
patients with perfusion defect than in those without (0.144 ±0.112
vs.0.047±0.104,respectively;P=0.003). No difference was found between
patients with anatomically significant stenosis and those without (0.054 ±0.116
vs.0.052±0.101;P=0.89).
Conclusion
Decrease in CCO across coronary stenosis is associated with
myocardial ischemia on APMRI. CCO is a novel method to assess the
hemodynamic significance of a stenosis, based on common cCTA data.
B-0774 10:57
CT coronary angiography: effect of iodine concentration on vascular
attenuation: the CT-CON multicentric study preliminary results
M. Rengo1, A. Dharampal1, M. Das2, M. Kock3, A. Niezen4, F. van Tilborg5,
D. Caruso1, K. Nieman4, G.P. Krestin4; 1Rome/IT, 2Maastricht/NL,
3Dordrecht/NL, 4Rotterdam/NL, 5Tilburg/NL (
[email protected])
Purpose: To explore the relative impacts of iodine concentration versus iodine
delivery rate on intracoronary attenuation. To describe the effect of iodine
concentration on contrast bolus characteristics.
Methods
and Materials: 675 patients were prospectively randomised in 4
groups and underwent CT coronary angiography (CTCA). Four CM with
different iodine concentrations (300, 350, 370 and 400 mgI/ml) were delivered
at a fixed iodine delivery rate (2.0 mgI/s). Intracoronary attenuation values
were measured and grouped on a per-vessel and per-segment bases. Time-to-
peak and pressure curves during CM injection were evaluated and compared.
Results
Injection fluxes were 6.7 ml/sec, 5.7 ml/sec, 5.4 ml/sec and 5 ml/sec
for group A, B, C and D, respectively. No significant differences were observed
among four groups in terms of intravascular density on a per-segment and per-
vessels analysis. Time-to-peak was significantly earlier in group A (15.3 sec)
than in the other three groups. The injection peak pressure was significantly
lower in group A (185.16 psi) and C (189.05 psi) than in group B (215.89 psi)
and D (243.33 psi). No extravasations were noted in all groups.
Conclusion
Contrast media with different iodine concentrations, if injected at
the same IDR, provide similar intravascular attenuation values. The lower
concentration contrast medium provided significantly lower injection pressure
values and a significantly shorter time to peak enhancement.
B-0775 11:06
Collateral classification by computed tomography in patients with
coronary total occlusion and its relation with downstream myocardial
infarction
J. Zhang; Shanghai/CN (
[email protected])
Purpose: To study the hypothesis that the filling pattern of distal collaterals
observed at coronary computed tomography angiography (CCTA) in patients
with chronic total occlusion (CTO) may correlate to the extent of myocardial
infarction (MI), with reference to cardiac magnetic resonance (CMR) imaging.
Methods
and Materials: All patients gave written informed consent and the
institutional review board committee approved the study protocol. 97 patients
(mean age: 68.5± 11.5, range 38 to 87 years, 77 males and 20 females) with
106 coronary total occlusions were prospectively enrolled in this study. Distal
collaterals were classified into three types according to their filling patterns
using Rentrop classification. Rentr op grade 3 was considered as well-
developed collaterals and Rentrop grade 0-2 were considered as poorly
S304
BA C D E F G
Monday
developed collaterals. Downstream myocardial infarction and wall motion
abnormality was verified by CMR semi-quantitatively. Mann-Whitney U test
was used for comparison.
Results
The overall diagnostic accuracy of CCTA classification of distal
collaterals was 86.8% (92/106), with correlation to invasive coronary
angiography (ICA). Highest collateral grading was associated with non-MI
subgroup whereas lowest grading was associated with transmural-MI subgroup
(2.7±0.6 versus 1.8 ±1, p=0.005). Compared to poorly developed collaterals
group, well-developed collaterals group (Rentrop grade 3) correlated to lower
summed transmurality score (1.4± 2.5 versus 3± 2.6, p < 0.001) and lower
summed regional wall motion abnormality score (0.5 ±1.7 versus 1.1 ±2,
p=0.029).
Conclusion
The presence of well-developed distal collaterals as revealed by
CCTA in patients with CTO lesions correlates to the lower frequency and
extent of downstream MI.
B-0776 11:15
The impact of combining low-tube voltage scanning with iterative
reconstruction on total iodine dose in coronary CT angiography
T. Van Cauteren, N. Buls, K. Tanaka, D. Verdries, G. Van Gompel, K. Nieboer,
I. Willekens, G. Verfaillie, J. De Mey; Brussels/BE
(
[email protected])
Purpose: To assess the impact of combining low-tube voltages and iterative
reconstruction (IR) on contrast dose in coronary CTA.
Methods
and Materials: A standard of care (SoC) 120 kVp scan with
320 mgI/ml iodine-based contrast (Visipaque, GE Healthcare) and FBP
reconstruction was compared with two study protocols: 80 kVp with 160 mgI/ml
(protocol A) and 100 kVp with 200 mgI/ml (protocol B), both reconstructed with
IR (ASiR). Each protocol was scanned (Discovery) three times on two minipigs
(Ellegaard) with constant injection protocol (speed 3 ml/s, volume 1.5 ml/kg)
and radiation dose. Quantitative image quality was evaluated by CT-value and
signal-to-noise ratio (SNR) of the right coronary artery (RCA), left anterior
descending coronary (LAD) and left circumflex artery (LCx). Expert readers
performed qualitative assessment for overall quality, vessel sharpness, noise
and streak artefacts.
Results
Despite reduced iodine load, both study protocols did not yield
inferior CT-value and SNR for all arteries. For RCA, the mean SoC signal
(307 HU) was preserved with protocol A (273 HU, p=0.15) and B (258 HU,
p=0.08). Also the SNR was non-inferior from SoC (SNR=7.0) with A (8.1,
p=0.75) and B (8.7, p=0.57). All scans were perceived to be of at least
acceptable quality on all evaluated parameters allowing diagnostic
interpretation. No statistical differences were observed (all p-values > 0.12),
except for streak artefacts (p=0.01) who were considered to be more severe,
although acceptable, with protocol A.
Conclusion
The use of a reduced tube voltage combined with iterative
reconstruction allows a marked reduction in iodine dose up to a factor of two
without impairing image quality.
Author Disclosures:
N. Buls: Advisory Board; GE Healthcare. K. Nieboer: Advisory Board; GE
Healthcare. J. De Mey: Advisory Board; GE Healthcare. Research/Grant
Support; GE Healthcare.
B-0777 11:24
Modified Morise score in predicting obstructive coronary artery disease
prevalence at 64-row coronary CT angiography
N. Tomizawa, Y. Hayakawa, T. Nojo, S. Nakamura; Matsudo/JP
(
[email protected])
Purpose: To evaluate modified-Morise score (MMS) including contrast
medium arrival time (AT) in conventional Morise score to predict obstructive
coronary artery disease (CAD) prevalence in coronary CT angiography.
Methods
and Materials: Consecutive 665 patients who underwent coronary
CT angiography were restrospectively included. AT was determined as the
time from the start of the injection to the threshold of 100 HU at the descending
aorta during the bolus-tracking scan. Morise pre-test score was calculated for
each patient. AT-heart-rate product (AHP) and MMS was defined as AT*heart
rate/100 and AHP*Morise score/10, respectively. Obstructive CAD was
determined as stenosis 50% at coronary CT angiography.
Results
A total of 441 patients (66%) showed no obstructive CAD. AT, AHP
and MMS were larger in patients with obstructive CAD compared with patients
without (19.1 vs 18.7; p = 0.06, 11.8 vs 11.3; p = 0.0014, 15.7 vs 13.7;
p < 0.0001). Receiver operating characteristics analysis showed that MMS
significantly improved the area under the curve compared with Morise score
alone in predicting obstructive CAD (0.63 vs 0.59; p = 0.01). The prevalence of
obstructive CAD was significantly higher in the second to fourth quartiles
compared with the first quartile of MMS (odds ratio (OR): 2.21, 95% confidence
interval (CI): 1.34-3.71; OR: 2.66, 95%CI: 1.63-4.41 and OR: 3.72, 95%CI:
2.28-6.18, respectively).
Conclusion
Larger MMS was associated with higher prevalence of
obstructive CAD. MMS had an additive value over the Morise model alone to
predict obstructive CAD in coronary CT angiography.
B-0778 11:33
The cost-effectiveness of cardiac CTA for the detection of significant
coronary artery disease in patients undergoing pre-operative liver
transplantation evaluation
T. Rosamond, L. Wetzel, D. Stanojevic, R. Genton, P. Tadros, R. Gilroy;
Kansas City, KS/US (
[email protected])
Purpose: Screening for significant coronary artery disease (CAD) in pre-liver
transplantation candidates with end-stage liver disease is controversial due to
concerns about screening test (ST) accuracy and cost-effectiveness (CE). This
economic evaluation modeling study was performed to determine the CE of
coronary CT angiography (CTA), dobutamine stress echo, SPECT imaging,
and invasive cardiac CATH compared to a no screening test strategy (NST).
Methods
and Materials: A retrospective review of 242 consecutive transplant
candidates was conducted to define model inputs for decision analysis.
Perspective: large tertiary academic university hospital in the Midwest USA.
Other sources: extant literature, systematic reviews, meta-analysis, hospital
accounting and clinical testing laboratory certification data, and expert panel
input utilising a modified Delphi exercise. Outcome measure: net monetary
benefit (NMB), willingness-to-pay (WTP) criteria and incremental health care
cost and quality adjusted life years (QALYs) gained, one-way and probabilistic
sensitivity analysis.
Results
CTA is the optimal ST strategy with an incremental effect of 1.16
QALYs gained at an incremental cost of $31,632 equivalent to $27,222 per
QALY gained (ICER) when compared to the undominated NST. CTA resulted
in a NMB of $36,186 assuming a WTP of $50,000, at a cost per QALY of
$42,248 and demonstrated extended dominance over the alternative screening
test strategies. According to sensitivity analysis the results are dependent only
upon the prevalence of CAD and were insensitive to screening test and
interventional costs.
Conclusion
When compared to a NST, CTA may be more cost-effective than
other imaging modalities in the evaluation of liver transplant candidates.
B-0779 11:42
Dose optimisation in coronary CT angiography: is it restricted to the
prospective ECG gating mode? Results from a multicentre study
F. Mafalanka
1, J.-L. Rehel1, D. Pesenti-Rossi2, L.-P. Christiaens3,
R. Convers-Domart4, P. Ou5, E. Schouman-Claeys5, M. Sirol5, C. Etard1;
1Fontenay-aux-Roses/FR, 2Neuilly-sur-Seine/FR, 3Poitiers/FR,
4Le Chesnay/FR, 5Paris/FR (
[email protected])
Purpose: To compare patient dose in coronary Computed Tomography
Angiography (cCTA) using different dose reduction techniques and different CT
scanners.
Methods
and Materials: Volume Computed Tomography Dose Index
(CTDIvol) was retrospectively collected from 387 cCTA performed in 7 centres,
within both academic and non-academic hospitals specialised in cardiac
imaging, using 64-, 128- or 320-detector CT scanners. About 50 examinations
were collected in each centre over a 3 months period, using the routine local
protocols, taking differently into account the Body Mass Index (BMI).
Prospective ECG-gating was used in 4 centres and iterative reconstruction (IR)
in 5 centres. Image quality was considered satisfactory in each centre and has
not been evaluated in this study. Data were analysed by the French National
Institute for Radiation Protection (IRSN).
Results
Mean CTDIvol per centre varied by a factor of 4.5 (range of
means±SD: 14±6 to 63±9 mGy). Minimum and maximum values were collected
on CT scanners using IR. The dispersion of the mean CTDIvol was more
important using retrospective compared to prospective gating (21 ±10 to
63±9 mGy and 14±6 to 31±15 mGy respectively).
Conclusion
Prospective ECG gating and IR are efficient dose reduction
techniques in cCTA but they do not exempt the centres from a more global
optimisation approach. Whatever the brand and the generation of CT scanner,
a significant dose optimisation is possible, using simple methods such as tube
current and voltage adaptation to the BMI.
B-0780 11:51
Comparison of three iodine concentrations in the visualisation of
coronary arteries by CT: a randomised European multicenter trial
M.H.K. Hoffmann and X-ACT Investigators; Lucerne/CH
(
[email protected])
Purpose: To assess the diagnostic efficacy of iobitridol (Xenetix® 350)
compared to iopromide (Ultravist® 370) and iomeprol (Iomeron® 400) in the
visualisation of coronary arteries.
Methods
and Materials: Randomised, double blind, non-inferiority phase IV
trial including 468 patients with suspected coronary artery disease (CAD) who
S305
BA C D E F G
Monday
were scheduled to undergo CT angiography. The primary endpoint was the CT
scan evaluability for CAD diagnosis in terms of quality and interpretability of
images. It was based on the full evaluation of 18 coronary segments for each
patient and assessed by 2 off-site independent readers. Secondary endpoints
were related to the safety and efficacy of the 3 contrast media (mainly image
quality, stenosis assessment, and signal quantification).
Results
Out of the 452 patients completed for the primary analysis, 92.1%
had their 18 segments fully evaluable in the iobitridol group, vs. 94.6 and
95.4% in the iomeprol and iopromide groups, respectively. Non-inferiority was
statistically demonstrated between the 3 products, and no relevant differences
between the 3 groups were observed for secondary endpoints. Eventually, the
good general safety profile of products was confirmed.
Conclusion
This large trial shows that an optimal benefit/risk ratio is achieved
as soon as an iodine concentration of 350 mgI/ml is administered for the
visualisation of coronary arteries.
Author Disclosures:
M.H.K. Hoffmann and X-ACT Investigators: Advisory Board; NVT
Technologies Hechingen Germany. Research/Grant Support; Guerbet.
Speaker; Abbott Vascular Philips Medical Systems.
10:30 - 12:00 Room D
Chest
SS 1704
Challenges in oncologic imaging
Moderators:
F. Gleeson; Oxford/UK
M.O. Wielpütz; Heidelberg/DE
B-0781 10:30
Comparisons of capability for TNM and clinical stage assessment in non-
small cell lung cancer patients among whole-body MRI, whole-body FDG-
PET/CT and co-registered whole-body PET/MRI
Y. Ohno
1, S. Seki1, M. Nishio1, H. Koyama1, T. Yoshikawa1, S. Matsumoto1,
K. Aoyagi2, H. Yamagata2, K. Sugimura1; 1Kobe/JP, 2Otawara/JP
(
[email protected])
Purpose: To directly compare the capability for clinical stage assessment
among whole-body MR imaging (MRI), integrated FDG-PET/CT and co-
registered FDG-PET/MRI in non-small cell lung cancer (NSCLC) patients.
Methods
and Materials: 70 consecutive pathologically diagnosed NSCLC
patients prospectively underwent whole-body MRI at 3 T system, integrated
FDG-PET/CT, conventional radiological examination, surgical treatment,
pathological examination and more than 2-year follow-up examinations. Final
diagnosis of TNM factors and clinical stage in each patient was determined
according to all examination results. All co-registered FDG-PET/MRIs were
generated by means of our proprietary software. Then, TNM factor and clinical
stage on all methods were visually assessed by radiologists and nuclear
medicine physicians. Then, final dia gnosis in each patient was made by
consensus of two readers on each method. To determine the agreements of
TNM factor and clinical stage between each method and final diagnosis, kappa
statistics were performed. To compare the diagnostic capability for operability
assessment among all methods, sensitivities, specificities and accuracies were
statistically compared each other by using McNemar's test.
Results
Each agreement with final diagnosis was as follows: T factor,
0.9050.93; N factor, 0.6050.88; M factor, 0.78 50.93; clinical stage,
0.5550.87, respectively. When compared each operability assessment
capability, sensitivity (100 ) %) and accuracy (95.7 ) %) of
clinical stage assessment on MRI were significantly higher than those
(sensitivity: 88.2 ) %, p < 0.05; accuracy: 87.1 ) %, p < 0.05)
of PET/MRI and PET/CT.
Conclusion
Whole-body MRI is more accurate than co-registered FDG-
PET/MRI and integrated FDG-PET/CT for clinical stage assessment in NSCLC
patients.
Author Disclosures:
Y. Ohno: Research/Grant Support; Toshiba Medical Systems Corporation,
Eizai Co. Ltd., Daiichi-Sankyo, Co. Ltd, Guerbet Japan. M. Nishio:
Research/Grant Support; Toshiba Medical Systems Corporation. T.
Yoshikawa: Research/Grant Support; Toshiba Medical Systems
Corporation.s. Matsumoto: Research/Grant Support; Toshiba Medical
Systems Corporation. K. Aoyagi: Employee; Toshiba Medical Systems
Corporation. H. Yamagata: Employee; Toshiba Medical Systems Corporation.
B-0782 10:39
Evaluation of dual-input perfusion in lung cancer: using a 640-slice
volume CT scan
E.-J. Kang1, K.-N. Lee1, J.-Y. Han1, J. Lee2; 1Busan/KR, 2Daegu/KR
(
[email protected])
Purpose: The purpose of our study was to assess the dual blood input supply
of lung cancer using a CT perfusion technique, and to analyse the correlations
between dual perfusion and various characteristics of lung cancer.
Methods
and Materials: Thirty-six consecutive patients with lung tumour that
highly suggestive of malignancy were included in this study. All subjects
underwent a dual-input dynamic perfusion volume scan using 320-raw-detector
CT before CT-guided biopsy. Pulmonary trunk and descending thoracic aorta
were selected for arterial input functions. From the computed CT data,
pulmonary arterial perfusion (PP), aortic perfusion (AP) and perfusion index
[PI, = PP/(PP+AP)] were calculated using the dual-input maximum-slope
method. We statistically analysed the rela tionship of perfusion data with tumour
locations (central, peripheral, and abutting the pleural locations), tumour
volumes, pathologic type, and the presence of lymph node or distant
metastasis.
Results
All subjects were pathologically diagnosed as primary malignant lung
cancers by the CT-guided aspiration biopsy. The overall mean PI was
53.3 ± 7.5%. The PI's showed significant difference by the tumour locations
(central, 49.2 ± 3.3; peripheral, 55.5 ± 7.2; abutting the pleural, 48.9 ± 7.6, P
=0.043). In contrast, no significant difference was presented by tumour sizes (r
= -0.252, P = 0.139) and by the presence of metastasis (P > 0.05).
Conclusion
We found the proportion of the dual perfusion in lung cancer is
significantly dependent on tumour locati on, and this result may benefit of the
management of lung cancer or prediction of prognosis.
B-0783 10:48
Discriminating between pneumonia and atelectasis on contrast-enhanced
computed tomography: a quantitative approach
R.M. Edwards, G. Kicska; Seattle, WA/US (
[email protected])
Purpose: It is well known that atelectasis demonstrates greater enhancement
than pneumonia on contrast-enhanced CT. However, radiologists underutilise
this information because a quantitative threshold has never been determined
discriminating between pneumonia and at electasis. Our study establishes this
threshold, which may allow for earlier diagnosis and treatment of pneumonia.
Methods
and Materials: CT pulmonary angiogram (CTPA) exams containing
consolidations were identified between 1/1/2012 and 7/31/2013. Consolidation
was diagnosed as atelectasis (12 patients) or pneumonia (18 patients) based
on multiple clinically accepted criteria. Hounsfield attenuation was measured in
consolidated lung parenchyma (CL), ascending aorta (Ao), main pulmonary
artery (MPA), and non-consolidated lung (NL). Mean enhancement values
were compared of CL, Ao, MPA, NL in subjects with pneumonia and
atelectasis. ROC analysis was performed to determine sensitivity and
specificity of enhancement diagnosing pneumonia.
Results
The mean enhancement of atelectatic and pneumonia consolidations
was 110.1 HU and 58.8 HU, respectively (p-value = 4.58E-07). There was no
statistically significant difference in Ao, MPA and NL enhancement between
pneumonia and atelectasis patients. The optimal threshold for discriminating
regions of pneumonia from atelectasis in this sample was 70 HU (CI: 69,
97 HU). Using this threshold, where 70 would indicate pneumonia, the
sensitivity and specificity for pneumonia was 93% (CI: 63, 99%) and 100% (CI:
88, 100%), respectively.
Conclusion
A threshold enhancement of 70 HU on a CTPA exam excludes
pneumonia with a high degree of certainty. In combination with clinical history,
a threshold of 70 HU enhancement allows for earlier and diagnosis treatment
of pneumonia.
Author Disclosures:
G. Kicska: Grant Recipient; General Electric.
B-0784 10:57
Solitary fibrous tumours of the pleura: are there any scanographic
features suggestive of malignancy? A 56-patient case series with
anatomopathological correlation
S. Hélage, M.-P. Revel, A. Mansuet-Lupo, É. Audureau, M. Alifano, D. Vadrot;
Paris/FR (
[email protected])
Purpose: To identify scanographic features predictive of anatomopathological
malignancy, from a retrospective study of preoperative CT scans of resected
solitary fibrous tumors (SFT) of the pleura.
Methods
and Materials: CT scans of operated patients between December
2004 and November 2012 were analysed retrospectively. Scanographic
features were studied without knowing anatomopathological diagnosis.
Results
The study population consisted of 56 patients (33 females and 23
males, mean age: 60 years old). SFT was asymptomatic, diagnosed
incidentally in 22 cases (45.83%). Anatomopathological examination of
S306
BA C D E F G
Monday
resection specimens (R0 resection in all cases) revealed that 23 tumors
(41.07%) were histologically malignant. The significantly different criteria
between malignant and benign types were: size (p=0.002) with a discriminatory
threshold of 10 centimeters, tumor heterogeneity spontaneously (p=0.019) or
after contrast medium injection (p=0.029), existence of intratumoral fluid
density areas (p=0.011), a pleural effusion (p=0.010), measurable intratumoral
vessels (p=0.019), a hypervascular character (intratumoral vessels and/or
intense enhancement) (p=0.001). Intratumoral calcifications (p=0.200) and
maximum post contrast density (p=0.58) were not significantly different.
Conclusion
CT features suggestive of anatomopathological malignancy of a
SFT are: size greater than or equal to 10 centimeters, tumor heterogeneity, a
hypervascular character of the tumor, presence of pleural effusion.
B-0785 11:06
The role of multi-sequence MR in the detection of pulmonary nodules
A. Lisowska, A. Cieszanowski, R. Krenke, P. Korczynski, M. Dabrowska,
M. Zukowska, O. Rowinski; Warszawa/PL (
[email protected])
Purpose: The purpose of this study was to assess the role of multi-sequence,
multiplanar MRI in the detection of pulmonary nodules as compared to
computed tomography (CT).
Methods
and Materials: Thirty patients underwent both MRI and MSCT of the
lungs (age range: 54-83 years, mean: 67.3). MRI (1.5 T) studies were
performed in the following sequences: axial and coronal T2 TSE and T1 3D
GRE and axial FatSat T2 TSE, T2 STIR, T2 HASTE and chemical shift
imaging. Data was independently analysed by two blinded radiologists. MRI
data was then compared to MSCT and verified to include a one-to-one
correlation of nodule size and location. The general sensitivity, diameter-based
sensitivity and MR sequence sensitivity was assessed in correlation to the
detection rate of lung nodules.
Results
The overall sensitivity of MRI was 79.2%. MRI sensitivity according to
nodules size was: 0% for nodules 3 mm, 77.8% for nodules between 3.1 mm
and 7.9 mm, 100% for nodules between 8 mm and 19.9 mm and 100% for
nodules between 20 mm and 30 mm. The positive predictive value (PPV) for
the detection of pulmonary nodules was: 47% for nodules 3.1 - 7.9 mm, 81%
for nodules 8 - 19.9 mm and 100% for nodules 20 - 30 mm.
Conclusion
MRI of the lungs does not allow for the detection of nodules
3 mm and shows moderate sensitivity for the detection of nodules between 3.1
and 7.9 mm. MRI yielded a 100% sensitivity for the detection of pulmonary
nodules 8 mm.
B-0786 11:15
Steady-state free-precession sequence in differentiating lung cancer from
adjacent atelectasis
T. Saida, S. Shiotani, T. Kobayashi, K. Mori, K. Nasu, H. Ishikawa, H. Ichimura,
M. Minami; Tsukuba/JP
Purpose: Inoperable, advanced lung cancer is often accompanied with
adjacent atelectasis. Differentiation between cancer and atelectasis is
necessary to determine the field of radiation therapy or to evaluate the effect of
therapy. Computed tomography (CT) is the gold standard, however, it is often
difficult to distinguish cancer from atel ectasis. Recently, diffusion-weighted
imaging (DWI) has been reported as useful for this purpose, however, the
image quality and anatomical information of DWI is insufficient. The aim of this
study is to evaluate the steady-state free precession sequence (SSFP) for
differentiating lung cancer from atelectasis.
Methods
and Materials: Ten patients suspected of lung cancer with adjacent
atelectasis on CT underwent magnetic resonance (MR) imaging. Using a 1.5-T
scanner, DWI (b=0.1000 s/mm
2), T2-weighted images (T2WI) and SSFP were
performed and apparent diffusion coeffici ent (ADC) and relative contrast of
T2WI and SSFP were calculated for cancer and atelectasis. In addition, two
independent observers evaluated the differentiating ability and the image
quality using the 3-point scales. Statis tical analyses were performed with
paired t-test, Friedman test, Wilcoxon test, and analysis of variance.
Results
There was a significant difference between lung cancer and
atelectasis on all evaluated imaging sequences. However, SSFP showed
significantly high differentiating ability than T2WI and showed significantly
better image quality than DWI and T2WI.
Conclusion
Advantages of the SSFP were a short acquisition time to avoid
artefact and an inherent high contrast between lung cancer and atelectasis
with detailed anatomical information, and SSFP could be considered as a
useful modality.
B-0787
11:24
3D non-contrast-enhanced pulmonary perfusion MRI in non-small cell
lung cancer patients: comparison of capability for postoperative lung
function prediction with dynamic first-pass perfusion MRI, thin-section
CT and Q scan
Y. Ohno
1, S. Seki1, M. Nishio1, H. Koyama1, T. Yoshikawa1, S. Matsumoto1,
Y. Kasai2, M. Yui2, K. Sugimura1; 1Kobe/JP, 2Otawara/JP
(
[email protected])
Purpose: To directly the compare capability for postoperative lung function
prediction among non-CE- and CE-perfusion MRIs, thin-section CT and Q scan
in non-small cell lung cancer (NSCLC) patients.
Methods
and Materials: Thirty-five NSCLC patients underwent thin-section
MDCT, non-CE- and CE-perfusion MRIs, Q scan, surgical treatment and pre-
and postoperative FEV 1% measurements. All non-CE-perfusion MRIs were
acquired with an ECG-gated 3D half-Fourier fast SE sequence using a 3 T
scanner. On non-CE- and CE-perfusion MRIs and Q scan, each regional
perfusion rate in the resected lobe was determined as signal intensity or
radioisotope uptake ratio between resected lobe and total lung. Then,each
postoperative FEV
1% (poFEV1%) was predicted from preoperative FEV 1% and
regional perfusion rate in the resected lobe. poFEV 1%s of qualitative and
quantitative CTs were predicted preoperative FEV 1% and total and resected
lung segments and functional lung volumes determined by density-masked CT.
To determine the capability of non-CE-perfusion MRI for regional perfusion
assessment, regional perfusion rate of non-CE-perfusion MRI was statistically
correlated with that of CE-perfusion MRI and Q scan. To determine the
capability for prediction of postoperative lung function among all methods, each
predicted poFEV1% was correlated with actual poFEV1%.
Results
Regional perfusion rate of non-CE-perfusion MRI had significant and
excellent correlations with that of CE-perfusion MRI and Q scan (r=0.70,
p 0.88, p < 0.0001).
Conclusion
Non-CE-perfusion MRI has a potential for postoperative lung
function prediction, and is considered as valuable as other methods in NSCLC
patients.
Author Disclosures:
Y. Ohno: Research/Grant Support; Toshiba Medical Systems Corporation,
Daiichi-Sankyo, Co. Ltd., Bayer Pharma.m. Nishio: Research/Grant Support;
Toshiba Medical Systems Corporation. T. Yoshikawa: Research/Grant
Support; Toshiba Medical Systems Corporation.s. Matsumoto:
Research/Grant Support; Toshiba Medical Systems Corporation. Y. Kasai:
Employee; Toshiba Medical Systems Corporation. M. Yui: Employee; Toshiba
Medical Systems Corporation.
B-0788 11:33
Dynamic contrast-enhanced magnetic resonance imaging of lung lesions
using a straightforward technique for morphological and quantitative
kinetic analysis
M. Koenigkam Santos
1, E. Optazaite2, G. Sommer3, H.-P. Schlemmer2,
C. Heussel2, H.-U. Kauczor2, M. Puderbach2; 1Ribeirao Preto/BR,
2Heidelberg/DE, 3Basle/CH (
[email protected])
Purpose: To propose a straightforward technique for both morphological and
quantitative kinetic perfusion analysis of lung lesions using dynamic contrast
enhanced MRI.
Methods
and Materials: 36 patients with 39 lung lesions (size range, 10-
220 mm; 33 malignant) were prospectively scanned prior to therapeutic
intervention. Fat-suppressed volumetric-interpolated T1W gradient-echo (VIBE)
images were obtained during sequential short breath-holds after bolus
triggered contrast injection. To obtain higher temporal resolution during the first
passage of contrast, volume coverage of first 3 measurements was limited to
include the lesion. Subsequent acquisiti ons were obtained with 1, 3 and 4 min.
Two radiologists evaluated presence and morphology of enhancement
separately and blinded. ROI-based signal intensity (SI)-time curves were
created to evaluate the quantitative kinetic parameters.
Results
Readers agreed moderately in regard to enhancement morphology
and substantially in regard to presence of significant enhancement inside the
lesion. Different SI-time curve patterns and derived parameters (early peak of
enhancement, slope of enhancement, maximum enhancement, washout ratio
and relative enhancement at the 4
th minute) were obtained for all lesions. An
early peak > 15% showed 100% sensitivity to detect malignancy.
Conclusion
The proposed technique allows the analysis of nodules, masses
and consolidations, permits the evaluation of enhancement morphology /
progression together with the creation of SI-time curves, and acquirement of
derived quantitative perfusion parameters. This strategy is simple and robust,
based on visual and ROI-based analysis, and is therefore a step forward to
bring lung MRI into the clinical scenario.
S307
BA C D E F G
Monday
B-0789 11:42
Ground glass nodules evolution according with an history of tumour
M. Silva, F. Centra, D. Colombi, L. Ampollini, P. Carbognani, C. Rossi,
N. Sverzellati; Parma/IT (
[email protected])
Purpose: To test the relation between oncologic anmnesis and CT pattern of
growth in ground glass nodules (GGN).
Methods
and Materials: 209 GGNs were diagnosed by CT in 147 subjects at
our hospital. Demographic data and anamnesis were recorded. Subjects were
categorized according to history of tumor as follows: "oncologic" and "non-
oncologic". CT features of each GGN were assessed from an initial and a
follow-up CT. GGNs of each category were then divided into "persisting" or
"resolved". Pattern of growth in persisting GGNs was defined by an increase of
total diameter or an appearance/increase of solid component diameter.
Association of oncologic anamnesis with GGN growth was tested by Fisher's
exact test and Kruskall-Wallis test.
Results
The 209 GGNs were found in 98/147 (66.7%) oncologic and 49/147
(33.3%) non-oncologic subjects. Pure GGNs (pGGN) were evenly represented
in oncologic (91.9%) and non-oncologic (83.6%) subjects (p = 0.09).
Disappearance rate was similar between non-oncologic (13.1%) and oncologic
(20.27%) category (p = 0.24). Persisting GGNs showed similar growth rate
between non-oncologic (30%) and oncologic (22.9%) subjects (p = 0.34).
Growth pattern was associated with CT features of GGN, namely, diameter >
10 mm in pGGNs (HR = 15.43) and presence of solid component (HR =
23.08).
Conclusion
GGNs showed the same rate of growth pattern in either oncologic
or non-oncologic subjects. Growth was related to CT features of GGN in all
subjects, despite history of tumor. Therefore, CT management of GGN in
oncologic patients should follow the same parameters used for non-oncologic
subjects.
B-0790 11:51
Determining the lowest radiation dose parameters for virtual CT
bronchoscopy: how low can we go?
A.R. Seyal, K. Parekh, R. Agrawal, T.H. Grant, A. Goodwin, V. Yaghmai;
Chicago, IL/US (
[email protected])
Purpose: To study the impact of radiation dose reduction strategies and
reconstruction algorithms on conspicuity and size of endobronchial lesion by
virtual CT bronchoscopy.
Methods
and Materials: An anthropomorphic chest phantom containing a
1.2 cm bronchial polyp was scanned using 80, 100 and 120 kV and 10, 20, 40,
75 and 110 mA. Images were reconstructed with filtered back projection (FBP)
and sinogram-affirmed iterative reconstruction (SAFIRE) algorithms.
Randomised images were shown to two chest radiologists. Largest lesion
diameter was measured in axial section. Volume-rendered images were
evaluated for image quality and bronchial polyp conspicuity on a five-point
scale. A score of 4 (corresponding to good image quality and lesion
conspicuity) was considered acceptable for both. Paired t-test, Wilcoxon
signed rank test and kappa statistics were used for analysis.
Results
The lowest radiation parameter at which both image quality and
bronchial polyp conspicuity were given acceptable scores was 120 kV/10 mA
(0.378mSv) for both FBP and SAFIRE. Image noise, CNR and SNR improved
significantly for image sets reconstructed with SAFIRE when compared with
FBP (p 0.05).
The diameter measurements were similar for both radiologists below 1 mSv for
each reconstruction algorithm (p > 0.05). Inter-observer agreement was good
for lesion conspicuity (k=0.73).
Conclusion
Virtual CT bronchoscopy maintains good image quality and lesion
conspicuity at significantly reduced effective dose, regardless of the
reconstruction algorithm used. However, objective measures of image quality
significantly improved with iterative reconstruction.
Author Disclosures:
A.R. Seyal: Research/Grant Support; Educational Grant support from Siemens
Healthcare. K. Parekh: Research/Grant Support; Educational Grant support
from Siemens Healthcare.
10:30 - 12:00 Board Room B
Paediatric
SS 1712
The child before and after surgery
Moderators:
F.E. Avni; Lille/FR
R. Llorens; Valencia/ES
B-0791 10:30
Doppler ultrasound for preoperative assessment of hepatic
haemodynamics and prediction of early portal vein thrombosis after liver
transplantation in paediatric patients with biliary atresia
L. Gu, H. Fang, F. Li, S. Zhang; Shanghai/CN (
[email protected])
Purpose: To assess the preoperative hepatic hemodynamics in pediatric
patients with BA (biliary atresia) at Doppler US and determine whether the
ultrasonographic warning signs may predict early portal vein thrombosis (PVT)
after liver transplantation (LT).
Methods
and Materials: This retrospective study was approved by an
institutional review board; informed consent was waived. 128 pediatric patients
(66 male, 62 female, mean age, 11.73 months ±6.25 [standard deviation]) with
BA younger than 3 years of age underwent Doppler US within 7 days before
LT between October 2006 and June 2013. 7.03% experienced early PVT
(within 1 month after LT). Receiver operating characteristic (ROC) analysis was
performed to determine the optimal cutoff value for predicting early PVT.
Results
Of the 128 recipients, 32.03% (41 of 128 LT recipients) had a
hypoplasia PV, 40.63% (52 of 128 LT recipients) had a hepatofugal portal flow
and 31.25% (40 of 128 LT recipients ) had a high hepatic artery resistance
index (HARI) of 1. Optimal cutoffs for PV di ameter, PVVmax, and HARI were
4 mm, 20 cm/sec, and 1, respectively. S ensitivity and specificity were 88.89%
and 72.27% for PV diameter , 55.56% and 58.82% fo r PVVmax, 77 .78% and
62.18% for hepatofugal PV flow, and 77.78% and 72.27% for HARI,
respectively.
Conclusion
Liver hemodynamic disturbances including PV hypoplasia
(32.0%), hepatofugal PV flow (40.63%) and high HARI (31.25%) were mainly
observed in BA. Small PV size ( 4 mm) are strong warning signs for the
prediction of early PVT, and hepatofugal PV flow and high HARI ( 1) had
relatively high risk factor.
B-0792 10:39
MR foetal lung volume in congenital diaphragmatic hernia: association of
prenatal MR imaging findings with postnatal need for prosthetic patch
repair of the hernia
C. Hagelstein, K. Zahn, M. Weidner, C. Weiss, T. Schaible, S.O. Schönberg,
K.A. Büsing, K.W. Neff; Mannheim/DE (
[email protected])
Purpose: To assess whether the type of surgical closure of the diaphragmatic
defect (primary vs. prosthetic patch repair) in neonates with congenital
diaphragmatic hernia (CDH) is associated with the antenatal measured
observed-to-expected MR-FLV (o/e MR-FLV).
Methods
and Materials: Using T2-weighted HASTE imaging, the o/e MR-FLV
was calculated in 247 foetuses with isolated CDH between 24 and 40 weeks
gestation. Logistic regression analysis and receiver operating characteristics
(ROC) analysis were performed to assess the prognostic value of the individual
o/e MR-FLV for association with postnatal need for prosthetic patch repair of
the hernia.
Results
77% (190/247) of the patients with CDH required patch repair and in
23% (57/247) the diaphragmatic defect was closed primarily. Patients with
patch requirement showed a significantly lower o/e MR-FLV (27.7 ±10.2%) than
patients with primary repair (40.8 ±13.8%, p < 0.001, AUC=0.786). With a
prenatally assessed o/e MR-FLV of 20%, 92% of the patients with CDH
required patch repair, compared to only 24% of the foetuses with an o/e MR-
FLV of 60%. Postnatal patch requirement was further influenced by the liver
position (liver herniation vs. no liver herniation) determined during foetal MR
examination (p < 0.001). Foetal liver position additionally to the o/e MR-FLV
improves the prognostic accuracy (AUC=0.827).
Conclusion
Logistic regression analysis based on the prenatally measured
o/e MR-FLV is useful for prenatal estimation of prosthetic patch requirement in
patients with CDH. In addition to the o/e MR-FLV, the position of the liver
determined by foetal MR imaging helps to improve the prognostic accuracy of
the estimated probability of patch requirement.
S308
BA C D E F G
Monday
B-0793 10:48
Utility of real-time US-guided percutaneous liver biopsy in paediatric liver
transplant recipients
S. Mandal1, R. Miraglia2, L. Maruzzelli2, R. Liotta2, K. Cortis2, A. Luca2;
1Pittsburgh, PA/US, 2Palermo/IT (
[email protected])
Purpose: The purpose of this study was to assess the safety of ultrasound
(US)-guided percutaneous liver biopsy (PLB) within paediatric liver allograft
recipients, to describe the pathological outcomes according to the early ( 12
months) and late (> 12 months) post-transplantation period, and to analyse the
value of liver function tests (LFT) and Doppler US variables in determining
these outcomes.
Methods
and Materials: Two hundred and nineteen consecutive real-time US-
guided PLB in 85 paediatric liver transplant patients (mean age 7 years, range
6 months-18 years) performed between March 2005 and May 2012 were
retrospectively evaluated. All patients underwent liver function testing and
Doppler US evaluation within one day of early (n=92, 42%) and late term
(n=127, 58%) post-transplantation biopsy.
Results
All samples were deemed adequate for histological analysis, 2
biopsies (0.91%) had complications consisting of mild bleeding requiring blood
transfusion. The early- and late-term biopsy results included cholestasis at
36% vs. 18% (p=.003), no pathology or minimal changes 16% vs. 24% (non-
significant, NS), acute rejection 13% vs. 5% (p=.027), inflammatory diseases
15% vs. 15% (NS), indeterminate acute rejection 11% vs. 7% (NS), chronic
rejection 4% vs. 14% (p=.017), fibrotic diseases 4% vs. 12% (NS), and other
diseases 0% vs. 5% (NS), respectively. Multinomial logistic regression
revealed that neither LFT nor US variable s are significantly correlated to
pathological outcomes.
Conclusion
The rate of complications after US-guided liver biopsy is very low.
A range of pathological outcomes exists between early and late post-
transplantation liver biopsy. LFT and Doppler US findings are not predictors of
pathological outcomes.
B-0794 10:57
Differential effect of right ventricular volume to left ventricular volume in
children with repaired tetralogy of fallot
Q. Yao, X.-H. Hu; Shanghai/CN (
[email protected])
Purpose: To compare the diagnostic value between indexed right ventricular
end-diastolic volume (RVEDVi) and the ratio of right ventricular volume to left
ventricular volume (RV/LV ratio) in prediction of the severity of pulmonary
regurgitation (PR) after surgery of tetralogy of Fallot (TOF).
Methods
and Materials: Tirty-nine consecutive patients with repaired TOF
(mean age of operation, 22.33 ±29.59 months; mean age of MRI, 81.62 ±50.85
months) were included in the study. RVEDVi, RV/LV ratio, and PR were
measured with the use of magnetic resonance imaging (MRI). PR fraction of
more than 20% was considered significant. The predictive capability of the two
markers (RVEDVi and RV/LV ratio) for significant PR was compared by using
multivariate linear regression analysis and receiver operating characteristic
analysis (ROC).
Results
A significant correlation between RVEDVi and the RV/LV ratio was
demonstrated (r = 0.776, P=0.0001). Both RV/LV and RVEDVi had correlation
with PR in correlation analysis (r=0.435/0.353, P=0.006/0.027), but in
multivariate analysis, the only independent predictor of PR fraction was the
RV/LV ratio (F=8.835, P=0.005). ROC analysis revealed better discrimination
of significant (20%) from insignificant ( < 20%) PR with the use of the RV/LV
ratio than RVEDVi (area under the receiver operating characteristic curve,
0.751 vs 0.711, P =0.01).
Conclusion
The RV/LV ratio is more accurate and useful than the RVEDVi in
stratification of PR.
B-0795 11:06
Prenatal diagnosis of fetal abdominal cystic masses: can MR change the
outcome?
S. Bernardo, V. Vinci, M. Saldari, P. Sollazzo, F. Capozza, A. Giancotti,
L. Manganaro; Rome/IT
Purpose: The purpose is to evaluate the role of fetal MRI in predicting
outcomes for fetuses with abdominal cystic masses.
Methods
and Materials: Forty-nine fetuses with doubtful US for fetal
malformation underwent MRI. All MRI findings were compared with
ultrasonographic findings regarding detection, anatomical localisation and
tissue characterisation. MRI findings were considered to have affected
management if subsequent treatment was influenced by the MR findings and
diagnosis.
Results
Out of the 49 fetuses, 44 had intra-abdominal cystic masses and
formed our study group. The mean GA was 27 weeks. Final individual
diagnoses were: meconium pseudocyst (n= 8), mesenteric cyst (n= 4),
hydrometrocolpos (n =1), small intestine duplication (n=7), ovarian cyst (n=4),
mesenteric lymphangioma (n=4), hydroneph rosis with pelvic-ureteric junction
obstruction (n= 3), choledochal cyst (n=6), urinoma (n= 2), megaureter caused
by posterior urethral valves (n= 1), m egabladder (n=3), persistent cloaca (n=
1). MRI was superior to sonography and had supplemental value because of
better anatomical localisation in 30 cases. Addition of MRI changed the
diagnosis and management in 21 cases. Eleven fetuses had neonatal surgical
treatment. In 33 cases, MRI provided additional information than US.
Conclusion
Prenatal MRI enhances fetal anatomic evaluation and facilitates
perinatal management and family counseling. Ultrafast imaging sequence MRI
is helpful to refine US diagnoses in delineation and characterisation of
abdominal cystic masses. Fetal MRI is a valuable adjunct to US for prenatal
diagnosis before fetal surgical intervention for selected life-threatening birth
defects.
B-0796 11:15
Quantification of aortic pressure gradients by 4D flow MRI in patients
with repaired aortic coarctation: comparison to echocardiography
F. Rengier
1, M. Delles2, J. Eichhorn1, Y.-J. Azad2, H. von Tengg-Kobligk1,
H.-U. Kauczor1, R. Unterhinninghofen2, S. Ley1; 1Heidelberg/DE,
2Karlsruhe/DE (
[email protected])
Purpose: In patients with aortic coarctation, routine follow-up after repair
includes measurement of pressure gradients by 2D echocardiography.
Purpose of this study was to compare pressure gradient measurements based
on 4D flow MRI with 2D echocardiography.
Methods
and Materials: 8 patients after repair of aortic coarctation (mean age
15.5 years) underwent 2D echocardiography and 4D flow MRI at 1.5 T with a
spatial/temporal resolution of 1.6x1.6x2.1 mm3/28 ms. Pressure gradient
measurements by echocardiography based on the simplified Bernoulli equation
were used for comparison. Pressure gradients by 4D flow MRI were
determined after automatic vessel segmentation applying two different
Methods
1, measurement of maximum blood flow velocities in the operated
aortic isthmus and calculation of pressure gradients using the simplified
Bernoulli equation; 2, computation of 4D pressure difference maps based on
the Navier-Stokes equation and measurement of the peak systolic difference
between mean pressures directly proximal and distal to the operated aortic
isthmus.
Results
Mean pressure gradient by echocardiography was 26.5 ±10.2 mmHg
compared to 18.0 ±6.9/13.0±6.2 mmHg by MRI Bernoulli method/MRI 4D
mapping method. Spearman correlation coefficients were 0.93 (p=0.001) for
MRI Bernoulli method and 0.76 (p=0.028) for MRI 4D mapping method. Bland-
Altman plots showed consistently lower pressure gradients for both MRI
Methods
compared to echocardiography.
Conclusion
Pressure gradient measurements based on 4D flow MRI showed
good correlation with consistently lower pressure gradients compared to
routinely performed measurements by 2D echocardiography. Since such
differences could be due to the pub lished possible overestimation of
echocardiography, further studies need to compare measurements by 4D flow
MRI to invasive measurements.
Author Disclosures:
H. von Tengg-Kobligk: Research/Grant Support; W. L. Gore & Associates,
Inc. H.-U. Kauczor: Research/Grant Support; Boehringer Ingelheim GmbH,
Siemens AG. Speaker; Boehringer Ingelheim GmbH, Bayer AG, Siemens AG.
B-0797 11:24
Acute appendicitis in children: multidetector CT and US findings in
negative appendectomy cases
S. Kim, Y. Choi, J. Cheon, W. Kim, I. Kim; Seoul/KR
(
[email protected])
Purpose: To evaluate the negative appendectomy rate (NAR) among different
imaging modalities, age groups and sexes and to describe the findings with US
and MDCT that cause radiologists to misdiagnose acute appendicitis in
paediatric patients.
Methods
and Materials: 382 patients were enrolled by reviewing their medical
charts. Among them, 348 patients were confirmed with acute appendicitis,
while 26 patients were confirmed as negative for appendicitis. The NAR was
compared and the radiological reports and imaging findings from US and
MDCT in the negative appendectomy cases were retrospectively reviewed.
Results
Overall, the NAR was 7.0%. The NAR was lowest in the group
receiving MDCT only (5.6%), was highest in age group of 0-4 years old
(14.7%), and was higher in the male paediatric population (9.2%), but there
were no statistically significant di fferences. The most common misleading
finding in US was equivocal dilatation of the appendix with associated
sonographic tenderness and/or noncompressibility (13/16, 81%). The two most
common misleading findings in CT were the borderline diameter of the
appendix with appendicolith or hyperdense fecalith (5/12, 42%) and secondary
inflammatory changes in the appendix (4/12, 33%). In almost all the negative
appendectomy cases, periappendiceal fat inflammation was not present on the
imaging studies.
Conclusion
The radiologists may misdiagnose acute appendicitis, especially
when sonographic tenderness or noncompressibility is present on US
S309
BA C D E F G
Monday
examination, and an appendicolith or hyperdense fecalith is noted on the
MDCT scan. The absence of periappendiceal fat inflammation either on US or
MDCT, provides some clues for the exclusion of acute appendicitis.
B-0798 11:33
Imaging features of childhood desmoplastic small round cell tumour
A. Youssef, Y. Mahfouz, A. Refaat, T. Rafaat, E. Mahmoud, M. EL Wakil,
I. Zaky; Cairo/EG (
[email protected])
Purpose: Desmoplastic small round cell tumour (DSRCT) is a rare aggressive
malignant small cell neoplasm tends to occur in children and adolescents, who
present with vague abdominal discomfort or distention and are often evaluated
with cross-sectional imaging. Our purpose is to review the imaging features,
histopathology and outcome of 10 patients with DSRCT treated at a single
institution.
Methods
and Materials: This is a retrospective observational study of patients
with DSRCT who presented to our hospital between 2010 and 2013. Ten
paediatric patients with pathologically proven DSRCT seen during this period.
Results
of imaging studies (CT in the ten patients, ultrasonography [US] in
three) and histopathologic specimens were analysed.
Results
The cohort of 10 patients included 1 male (1%) and 9 females (90%)
with a mean age of 12.7 years (range 9 to 17 years). The peritoneum affected
in the majority of cases (n=9) and pleura is affected only in one case. There
were 3 patients (33%) had metastatic disease at presentation. The hallmark
imaging feature was diffuse peritoneal thickening with multiple focal lobulated
peritoneal masses (n=6). Less common multiple focal peritoneal masses (n=3).
Ascites was present in five patients. Calcification was encountered in one
patient.
Conclusion
Desmoplastic small round cell tumour is uncommon, aggressive
small-cell tumour typically presenting with multiple large serosal soft-tissue
masses. The imaging of this tumour is somewhat nonspecific, yet this
uncommon diagnosis should be considered in assessment of young female
teenager presenting with widespread peritoneal malignant disease without
certain solid organ involvement.
B-0799 11:42
Noninvasive quantitative 4D pressure difference mapping derived from
4D flow MRI shows alterations in patients with repaired aortic coarctation
F. Rengier
1, M. Delles2, J. Eichhorn1, Y.-J. Azad2, H. von Tengg-Kobligk1,
H.-U. Kauczor1, R. Unterhinninghofen2, S. Ley1; 1Heidelberg/DE,
2Karlsruhe/DE (
[email protected])
Purpose: To assess spatial and temporal pressure characteristics in patients
with repaired aortic coarctation compared to young healthy volunteers using
4D pressure difference maps derived from 4D flow MRI.
Methods
and Materials: 13 patients after aortic coarctation repair without
recoarctation (mean age 18.8 years) and 13 healthy volunteers (mean age
22.9 years) underwent 4D flow MRI of the thoracic aorta at 1.5 T.
Spatial/temporal resolution was 1.6x1.6x2.1 mm3/28 ms. 4D pressure
difference maps relative to the proximal ascending aorta were computed based
on the Navier-Stokes equation. The thoracic aorta was divided into four
segments: ascending aorta, aortic arch, proximal descending aorta and distal
descending aorta. For each segment, spatial pressure range at mid systole
and maximum slope of local pressure amplitudes were determined.
Results
Mean spatial pressure range at mid systole for patients/volunteers
was (in mmHg): ascending aorta 1.8/1.6 (p=ns), arch 4.8/1.7 (p=0.02),
proximal descending 8.9/1.6 (p < 0.001) and distal descending 2.8/1.6
(p=0.002). Mean maximum slope of local pressure amplitudes for
patients/volunteers was (in mmHg/cm): ascending aorta 7.4/2.5 (p=ns), arch
6.6/2.1 (p < 0.001), proximal descending 12.1/1.9 (p=0.002) and distal
descending 3.9/2.1 (p=0.002).
Conclusion
Noninvasive quantitative 4D pressure difference mapping derived
from 4D flow MRI showed significant alterations of spatial and temporal
pressure characteristics in patients with repaired aortic coarctation compared
to young healthy volunteers, particularly affecting aortic arch and proximal
descending aorta, but also distal descending aorta. The technique may evolve
into a noninvasive alternative to catheterisation in coarctation follow-up.
Author Disclosures:
H. von Tengg-Kobligk: Research/Grant Support; W. L. Gore & Associates,
Inc. H.-U. Kauczor: Research/Grant Support; Boehringer Ingelheim GmbH,
Siemens AG. Speaker; Boehringer Ingelheim GmbH, Bayer AG, Siemens AG.
10:30 - 12:00 Room E1
Musculoskeletal
SS 1710
Hip and artefacts reduction
Moderators:
P. Omoumi; Brussels/BE
A.P. Toms; Norwich/UK
B-0800 10:30
Measurement of acetabular cup orientation after total hip arthroplasty in
standing and sitting positions with a novel low dose biplanar slot
scanner
R. Ferré, C. Bourdet, A. Feydy, M. Hamadouche, J.-L. Drape, B. Guenoun;
Paris/FR (
[email protected])
Purpose: Improper positioning of the acetabular cup after total hip arthroplasty
(THA) is a cause of dislocation. Cup orientation (CO) is assessed with a
computed-tomography (CT) scan in the supine position. Slot scanner (SS)
allows a three-dimensional (3D) assessment of CO in standing and sitting
positions. The aim was to evaluate the interest of SS to assess CO.
Methods
and Materials: Fifteen THA patients were included after dislocation.
After reduction, a scan and SS acquisitions were performed to measure cup
anteversion both in the standing and sitting positions. 3D modelling of the
pelvises was performed by two independent observers with a dedicated
software, cup inclination and anteversion were calculated. Variations of cup
anteversion and inclination between the different positions were detected with
the student t-test. The interobserver agreements of the SS evaluation of CO
were assessed with the intraclass correlation coefficient (ICC).
Results
CT measurement of cup anteversion was 23.3°. SS measurement of
cup anteversion was 24.4° in the standing position and 37.2° in the sitting
position (p < 0.01). CT measurement of cup anteversion did not differ
significantly from SS measurement in the standing position (p=0.9), but the
difference between CT and SS was statist ically significant when considering
the sitting SS acquisition (p < 0.01). SS measurement of cup inclination was
43.6° in the standing position and 50.6° in the sitting position (p < 0.01).
Conclusion
Cup orientation shows significant variations between stand-up
and sat positions. SS might be a relevant and reliable tool to understand cases
of hip dislocations occurring during postural changes.
B-0801 10:39
Improving sensitivity of conventional MR arthrography in detection of
arthroscopically confirmed lig. teres lesions subsequent to FAI by adding
axial leg traction
F. Schmaranzer
1, M. Kogler2, M. Reichkendler2, E. Schmaranzer2;
1Innsbruck/AT, 2St. Johann in Tirol/AT
(
[email protected])
Purpose: Recent research focuses on the increasing relevance of lig. teres
lesions as contributors to hip pain and instability. Detection of these lesions is
challenging, thus it was aimed to improve diagnostic performance of MR
arthrography by adding leg traction.
Methods
and Materials: Out of 135 patients with FAI, 48 imaging studies
(mean age 34.6a, 34 mixed-, 12 cam-, and 2 pincer-type) with confirmed lig.
teres lesions were selected. MR arthrograms were obtained according to the
institutional routine protocol using a 1.5 T scanner and an intraarticular injected
volume of up to 30 ml. Weight load ranging from 15 to 23 kg was adapted to
constitution and applicated with a dedicated traction device. Lesions were
graded as partial tear (type 2; subtotal fluid interposition and/or ligamentous
flap) and degeneration (type 3; hypertrophy ± mucoid degeneration) on coronal
images ± traction. Overall sensitivity and se nsitivity for each imaging modality
as such was calculated.
Results
Overall sensitivity was 85.3% (35/41), 100% (7/7) for type 2, 3
lesions, respectively. Sensitivity of imag ing analysis without traction was 60.9%
(25/41) for type 2 and 57.1% (4/7) for type 3 lesions. 10 type 2 (P = 24.3%) and
3 type 3 lesions (P = 42.8%) were only seen with traction.
Conclusion
Traction improved detection of lig. teres lesions. It is
hypothesised that traction during MR arthrography enables visualisation of the
ligament more similar to the arthroscopic point of view that reflects a more lax
condition of stress thereby facilitating the evaluation of flaps, intrasubstantial
fluid accumulation and hypertrophy.
S310
BA C D E F G
Monday
B-0802 10:48
Femoroacetabular impingement pattern of hip involvement in ankylosing
spondylitis
J. Lee, J.-A. Choi, E. Lee, H. Kang; Seongnam/KR (
[email protected])
Purpose: To evaluate FAI patterns of hip involvement in AS and correlate with
sacroiliitis grades.
Methods
and Materials: 153 patients with AS were analysed regarding
radiologic signs of FAI, sacroiliitis grades. FAI was classified according to alpha
angle, lateral center-edge (CE) angle, crossover sign, pistol grip deformity.
Prevalence of FAI types was determined and evaluated for association with
sacroiliitis grades. Alpha angles were m easured on translateral radiographs or
oblique axial CT/MR images. Lateral CE angle, crossover sign, pistol grip
deformity were measured on AP radiographs. Sacroiliitis was graded according
to New York criteria. Cam type FAI was considered if flattening of head-neck
junction (pistol grip deformity) and/or alpha angle > 50°; pincer FAI if lateral CE
angle > 39°, and/or positive crossover sign; combined type with findings of both
types. Statistical analysis was done using Chi-square test for gender, T-test for
age, sacroiliitis score, Kruskal-Wallis test for sacroiliitis score, Mann-Whitney
U-test, corrected by Bonferroni methods.
Results
53 (34.6%) had FAI pattern of hip. Male predominance was found
(84.9%) (p=0.031). Hip involvement group showed greater sacroiliitis score
(p=0.001). Regarding type of FAI (n=53), pincer was most common (n=25).
Sacroiliitis grade was different among FAI types (p=0.002). Combined-type FAI
pattern (n=20, 3.20±0.77) had greater sacroiliitis score (p=0.018).
Conclusion
FAI pattern of hip involvement was frequent in AS (34.6%), more
frequent in males, associated with greater sacroiliitis grade. FAI type of hip
involvement should be considered in AS patients with hip symptoms and
managed accordingly.
B-0803 10:57
How common are hip labral tears? Comparison of individuals with and
without hip symptoms
S. Lee
1, L. Nardo1, U.R. Heilmeier1, D. Kumar1, M. Kretzschmar1, A. Yu1,
S. Majumdar1, N.E. Lane2, T.M. Link1; 1San Francisco, CA/US, 2Sacramento,
CA/US (
[email protected])
Purpose: To compare frequencies of hip la bral tear in individuals with and
without hip symptoms
Methods
and Materials: Ninety volunteers (49 male and 41 female, age range
23-72) were prospectively recruited for this cross-sectional study. All
underwent non-contrast 3 T MRI and clinical assessment for hip symptoms.
Three-plane non-contrast intermediate-weighted fast spin echo imaging
sequences were performed of the hip. Images were analysed for labral
pathology and other significant hip joint findings. Labral abnormalities were
classified into 4 groups, any tear, intra-substance tear, complex tear and
maceration. Hip pain, stiffness, noise such as clicking or grinding and stiffness
were assessed on a 5-point scale using the Hip Osteoarthritis Outcome score
(HOOS) questionnaire. Chi-square test was performed to assess the difference
of labral abnormality frequency in each symptom subgroup.
Results
Hip pain, noise and stiffness were reported in 49, 25 and 38 of the 90
subjects. The frequency of labral abnormalities were, any tear 91.1 %, intra-
substance tear 58.8 %, complex tear 43.3 % and maceration 14.4 %. No
significant differences in overall frequency of hip tears were found between
subjects with and without symptoms; i ndividuals with hip stiffness, however,
showed a statistically significant higher number of complex tears (P=0.01) and
a statistical trend toward increase in intra-substance tears (P=0.06).
Conclusion
A high percentage of labral tears were found in individuals with
and without hip pain, noise and stiffness. The only clinical symptom with
statistical frequency increase of hip l abral abnormality was hip stiffness, which
was associated with complex tears.
B-0804 11:06
Value of lower-limb MRI examination for the prediction of joint collapse in
haematological paediatric patients with osteonecrosis of femoral heads
and condyles: role of lesion volume assessment
A. Masetto, D. Ippolito, P.A. Bonaffini, A. Casiraghi, V. Besostri, S. Sironi;
Monza/IT (
[email protected])
Purpose: To assess the reliability of the measurement of the osteonecrosis
volume as predictive factor of joint collapse in femoral heads and condyles of
paediatric patients treated for haematologic malignancies.
Methods
and Materials: A total of 120 patients with lymphoproliferative
diseases, treated with chemotherapy and corticosteroids and/or bone marrow
transplant, with suspicion of osteonecrosis, underwent a lower-limb MRI
examination between June 2005 and January 2013. Studies were performed at
baseline and during follow-up on a 1.5 T magnet, acquiring coronal STIR and
T1-weighted sequences from the hips to the ankles. On baseline MRI, the
volumes of femoral heads (FHs), medial condyles (MCs), lateral condyles
(LCs) and the osteonecrosis volume (ONV) were measured. The volumetric
involvement (relative volume, RV) of the bone by necrosis was calculated
(ONV/epiphyseal bone volume). Statistical analysis was performed with ROC
curve test.
Results
Twenty-six patients (9 males, mean age 15 years) presented ON
affecting femoral heads and/or condyles, for a total of 23 FHs, 23 MCs and 28
LCs. During the follow-up (11 ±2 months), joint deformity was observed in
12 FHs, 2 MCs and 5 LCs. Considering a threshold of 24% of volume
involvement, RV predicted joint deformity in 12/12 FHs, with sensitivity=100%,
specificity=90%, accuracy=95%, PPV=93%, NPV=100%. Using a threshold of
27% and 11% of volume involvement, RV predicted joint deformity in 2/23 (8%)
MCs (sensitivity=100%, specificity=57%, accuracy=61%, PPV=9%,
NPV=100%) and in 5/28 (18%) LCs (SN=100%, specificity=35%,
accuracy=46%, PPV=25%, NPV=100%), respectively.
Conclusion
In haematological paediatric patients with post-treatment
osteonecrosis, RV showed high prognostic value for the prediction of deformity
in femoral heads, but not in femoral condyles.
B-0805 11:15
Model-based iterative reconstruction: reduction of metal artefact on CT
images
S. Boudabbous, D. Arditi, E. Paulin, A. Syrogiannopoulou, C.D. Becker,
X. Montet; Geneva/CH (
[email protected])
Purpose: To reduce artefacts resulting from implanted metal prosthesis on CT
images using model-based iterative reconstruction (MBIR).
Methods
and Materials: A total hip prosthesis, screws and metal plates were
scanned in vitro (CT Discovery, GEMS). Images were reconstructed with
filtered-back projection (FBP) and MBIR algorithms, and the size of the
resulting artefacts on each image series was measured. CT scans obtained
with the same scanner in 63 patients with similar implants were reconstructed
with FBP and MBIR. The visibility of the interface between metal and bone and
of the neighbouring soft tissue structures was recorded on each set of images
and graded on a 3-point scale.
Results
In vitro, the mean size of the artefacts was 1.4 cm
2 with FBP and
0.25 cm2 with MBIR corresponding to a reduction of 80%. In vivo, the size of
the artefacts decreased from 6.46 to 3.53 cm 2 (p < 0.0001) when using MBIR.
The interface between metal and bone was equal or better visible on images
reconstructed with MBIR than on those with FBP in 85% of cases (p < 0.05),
and the results for soft tissue evaluation were better in 75% of cases (p < 0.05)
particularly in pelvis.
Conclusion
Both qualitative and quantitative results showed that the MBIR
improve image quality by reduction of artefacts and better assessment of the
adjacent structures.
B-0806 11:24
WARP imaging of metal-on-metal hip resurfacing arthroplasty at 1.5 T
and 3 T MRI compared to standard imaging techniques: what more do we
see?
A. Lazik, O. Kraff, P. Schulte, S. Landgraeber, T.C. Lauenstein,
J.M. Theysohn; Essen/DE (
[email protected])
Purpose: To evaluate the metal artefact reduction technique WARP (Siemens
Healthcare) for the assessment of metal-on-metal hip resurfacing at 1.5 T and
3 T according to advantages and disadvantages over standard MR-sequences,
focused on the detection of pseudotumours.
Methods
and Materials: 23 arthroplasties (Conserve plus, Wright Medical
Technology) were evaluated 3 - 9 years after surgery, randomised for 1.5 T
and 3 T MRI. Additionally eight patients were examined at both field strengths
using the same protocol: TIRM, T1w and T2w TSE in coronal and axial
orientation, each with and without WARP (Bandwidth: 558 Hz/px (HBW), view-
angle-tilting 100% (VAT)). Sequences were evaluated regarding artifacts (size;
5-point-scale: 1= no artifacts, 5= no ndiagnostic), delineation of soft-tissue
structures (3-point-scale: 1= fully visible, 3= not visibl e) and the existence of
pseudotumours. The results were compared between the correlating
sequences.
Results
WARP showed less quality degradation through artefacts (i.e. 1.5 T
TIRM: 3.9 ±0.3 vs. 4.9 ±0.2) and smaller artefacts (i.e. 3 T T1w: 87.4 ±9.0 mm
vs. 100.6 ±3.8 mm). The delineation of soft tissue structures was better with
WARP (i.e. internal obturator tendon at 1.5 T T1w: 1.8 ±0.4 vs. 2.6 ±0.5).
WARP showed only slightly better results then HBW alone for the size of
artefacts. Pseudotumours appeared in 5 cases (19 - 30 mm), which could be
seen with and without WARP.
Conclusion
WARP is feasible at 1.5 T and 3 T for imaging hips after metal-
on-metal resurfacing and provides better image quality then standard
sequences. WARP shows a slight advantage over HBW alone. Detected
pseudotumours did not profit from WARP.
S311
BA C D E F G
Monday
B-0807 11:33
Usefullness of slice encoding metal artefact correction for reducing metal
artefact after spinal instrumentation
M. Reichert, M. Sertdemir, M. Moursy, H.P. Scharf, U.I. Attenberger,
S.O. Schönberg, F. Bludau; Mannheim/DE (
[email protected])
Purpose: To compare metal artifact reduction after spinal instrumentation in
MRI at 1.5 T using novel MRI sequence strategies.
Methods
and Materials: Two sequences were compared for the imaging of
metal implants after spinal instrumentation: a slice encoding sequence for
metal artifact correction (SEMAC) and a standard sequence. Images were
acquired on a 1.5 T system. 13 patients with titanium implants and 2 patients
with stainless steel implants were evaluated. Degree of artifact reduction was
assessed quantitatively and qualitatively by both, artifact measurements and a
blinded read. The images were ranked on the basis of the following
parameters: artifact size, distortion of normal structures, and the ability to
visualise the bone marrow, bone cortex and soft tissues. The SEMAC
technique was compared directly to the standard sequence.
Results
In comparison to conventional sequences artifact size was 45% less
utilising SEMAC. In terms of bone marrow, bone cortex and soft tissue
visualisation SEMAC was ranked superior to the corresponding standard
sequence. Distortion was less with SEMAC. For the evaluation of blur, the
standard images were ranked superior to the corresponding SEMAC
sequence. In terms of overall image quality, SEMAC was ranked superior to
the standard sequence.
Conclusion
SEMAC effectively reduces artifacts caused by metallic implants
after spinal instrumentation relative to standard imaging. This allows for an
improved detectability of postoperative complications such as epidural
inflammation or hematoma.
B-0808 11:42
Dual-energy CT of hip prosthesis: metal artefact reduction system image
and 140keV monochromatic image contrast and noise on non-prosthesis
side
M. Guzinski, L. Waszczuk, M. S siadek; Wroclaw/PL (
[email protected])
Purpose: To compare image quality (SNR, CNR) on non-hip prosthesis side in
dual-energy CT examinations obtained with different protocols: with metal
artefact reduction system (MARS) and high energy (140 keV) monochromatic
reconstruction without MARS.
Methods
and Materials: Hip prosthesis studies of 31 consecutive patients
(mean age 68 yrs) after hip prosthesis revision surgery were examined, using
DECT (GE Discovery CT750HD; 64x0.625 mm; pitch 1:1.375, 600 mAs). From
each patient, two series of monochromatic energy scan were obtained. First
with MARS and 75keV and second without MARS, 140keV. Two blind
radiologists reviewed two series of monochromtic image of DECT examinations
assessing image noise (SNR), contrast (CNR) on the side of hip prosthesis and
in mirror contralateral region. SNR and CNR in fat muscle for prosthesis' side
and opposite side were measured on the level of femoral head.
Results
There were no statistically significant differences between SNR of fat
on hip prosthesis and opposite site (4.8 vs. 5.2, p=0.07) in MARS image.
However, significant difference between SNR was found in 140keV images
(3.9 vs. 5.3, p=0.0001). Differences between CNR (fat/muscle) of both sides on
MARS and 140keV images were: 5.5 vs. 6.8, p=0.05; 5.9 vs. 7.3, p=0.05,
respectively.
Conclusion
In the monochromatic 140 keV image on non-prosthesis side, the
significant lower level of noise was detected. We propose to perform MARS
reconstruction in high voltage level.
B-0809 11:51
Reduction of metal artefact from cobalt-chromium-molybdenum alloy hip
prostheses in gemstone spectral imaging dual-energy CT with and
without metal artefact reduction software
F. Wang, H. Xue, W. Han, Y. Fan, W. Qian, Z. Wu, Y. Zhang, Z. Jin; Beijing/CN
(
[email protected])
Purpose: To assess the usefulness of gemstone spectral imaging (GSI) dual-
energy CT (DECT) with/without metal artefact reduction software (MARs) in
cobalt-chromium-molybdenum alloy hip prostheses, and to detect the optimal
photon energy setting.
Methods
and Materials: This study had institutional review board and local
ethics committee approval. The DECTs were performed using fast kV-
switching GSI between 80 and 140 kV. The CT data were reconstructed
with/without MARs, and with synthesized monochromatic energy in the range
of 70-140 keV with 10 keV interval. Seventeen in vivo cobalt-chromium-
molybdenum alloy total hip prostheses of 11 unilateral implanted patients and 3
bilateral implanted patients were included. Two independent readers evaluated
the visualisation of periprosthetic regions and the severity of artifacts according
to a 4-score scale. CT attenuation of gluteus maximus muscle ipsilateral to the
side of the replaced hip from non-metal level, acetabular cup and femoral head
level, femoral neck level, and femoral shaft level were measured. Statistical
analysis included the Chi-square test, and Friedman test.
Results
The GSI-MARs reconstruction markedly reduced the cobalt-
chromium-molybdenum alloy hip prostheses related artifacts (P < 0.05). CT
attenuation of gluteus maximus muscle in GSI-MARs images from the
acetabular cup and femoral head level (<2=4.765, P=0.029), femoral neck level
(<2=13.235, P=0.000), and femoral shaft level ( <2=7.118, P=0.008) was much
closer to the reference non-metal level. Optimal metal artefact reduction and
image noise could be achieved above 100 keV.
Conclusion
GSI-MARs reduced metal artefacts from cobalt-chromium-
molybdenum alloy hip prostheses. Optimal energy range was found between
110 and 140 keV.
10:30 - 12:00 Room E2
Head and Neck
SS 1708
Thyroid and parathyroid glands
Moderators:
H. Ahmadzadehfar; Bonn/DE
S.S. Özbek; Izmir/TR
B-0810 10:30
Role of TIRADS in nodular thyroid disease
B. Raghavan, S. Paul; Chennai/IN (
[email protected])
Purpose: 1. To classify nodular thyroid disease according to TIRADS
classification. 2. To correlate TIRADS categories with the rates of malignancy
in each category, in select study population. 3. To assess reliability of TIRADS
classification.
Methods
and Materials: 219 nodules were evaluated by B-mode imaging and
colour Doppler. These nodules were cl assified into TIRADS grades according
to the guidelines proposed by Horvath et al. The TIRADS subgroups (based on
B-mode imaging and colour Doppler) were compared with the cytopathological
diagnosis and analysed statistically using Chi-square test, and logistic
regression analysis to find out the correlation between the sonographic
variables and final cytological end resul t. The odds ratio for malignancy for
each TIRADS group was calculated thereby. "SSPS for Windows, Version 17"
was used for the statistical analysis.
Results
TIRADS is a system of classification for categorisation of thyroid
nodules. As such it can be used to predict tissue morphology, whether benign
or malignant. According to our study, univariate logistic regression of TIRADS
2 to TIRADS 4B with malignancy has an odds ratio (OR) of less than 1 with a
significant confidence interval. TIRADS has a statistically significant OR of
more than 1 when compared with malignancy.
Conclusion
TIRADS is a novel method of categorising nodular thyroid
disease. It helps in classifying these into benign and malignant according to
sonographic features. Thus, the need of biopsy can be reduced.
B-0811 10:39
Non-diagnostic results of fine needle aspiration cytology of thyroid
nodules
S. Jacobs
1, F. van Nederveen2, P. Burger2, R. Peeters2, M. Vernooij2,
A. van der Lugt2, J. Peluso3; 1Dordrecht/NL, 2Rotterdam/NL, 3 Tilburg/NL
(
[email protected])
Purpose: Fine needle aspiration (FNA) cytology has a central place in the
diagnosis of thyroid gland nodules. We evaluated the proportion of non-
diagnostic cytology results after first a nd after repeat FNA. Also the effect of
operator experience was evaluated.
Methods
and Materials: 483 cytology results of FNA performed in our
institution in 2010, 2011 and 2012 were available for retrospective analysis. 77
were excluded from further analysis (70 previous FNA before 2010, 3 second
repeat FNA, 4 interval > 6 months). 406 remaining cytology results in 336
patients were dichotomised using the Bethesda system with 1 as non-
diagnostic and 2 to 6 as diagnostic. Operator experience was categorised as
experienced (staff radiologist) or inexperienced (radiology resident).
Differences were analysed using the Chi-square test.
Results
The cohort consisted of predominantly females (N=250, 74%). Mean
patient age was 52.6 (median 53, 14-93). Non-diagnostic cytology occurred in
98 of 353 initial FNA (28%). Non-diagnostic cytology occurred in 20 of 53
repeat FNA (38%). Total non-diagnostic cytology after second FNA was 21%.
Approximately, 40% of the FNA was performed by a staff radiologist. There
was no significant difference between experienced and inexperienced
operators (25% and 32%; p=0.13).
S312
BA C D E F G
Monday
Conclusion
Although FNA cytology is a valuable tool in the evaluation of
thyroid gland nodules there is a high proportion of non-diagnostic test results
(28%). It is important to repeat FNA cytology because diagnostic results are
obtained in 62% of the previously non-diagnostic FNA. In this study, non-
diagnostic FNA cytology is not influenced by operator experience.
B-0813 10:48
Difficulties in the performance of ultrasound elastography of thyroid
malignancies
A.N. Sencha, Y. Patrunov, Y. Sergeeva; Yaroslavl/RU
(
[email protected])
Purpose: To analyse disadvantages, difficulties, and artifacts during
ultrasound elastography of thyroid cancer.
Methods
and Materials: Ultrasound examinations with elastography of 141
patients with verified thyroid cancer were analysed. The reference group with
verified benign nodules included 432 persons. The scanners S2000 (Siemens-
Acuson), SonixSP (Ultrasonix), DC-8 (Mindr ?y) with linear 7.5-15 MHz probes
were utilised.
Results
The efficacy of the combination of compression and share-wave
elastography in diagnosis of thyroid canc er was characterised with sensitivity
of 96.4% and specificity of 90.1%. Compression elastography was
accompanied with difficulties in interpretation in 13 cases (9.2%). In 4 cases
(2.8%) the artifact of excessive color pattern within the malignant lesion was
observed, while 9 cases (6.4%) had the artifact of poor (deficiency or absence)
color pattern or absence of difference between the color of the lesion and the
surrounding thyroid parenchyma. However, all lesions were well visualised in
other ultrasound regimens. Artifacts duri ng compression elastography resulted
from inadequate adjustments of equipment, "noise" due to thyroid lesion
location, different approaches in image processing in scanners of different
manufacturers, significant operator-dependency of the technology. Difficulties
in the performance of share-wave elastography were experienced in 12
(14.9%) cases. They were the consequence of substernal thyroid location,
subcentimetric or large ( > 3 cm) lesions, prominent heterogeneity of lesions,
and severe background changes in thyroid parenchyma. In 9 cases (6.4%)
compression elastography and share-wa ve elastography exhibited discordant
results.
Conclusion
Effective acquisition and interpretation of elastographic images
demands certain knowledge, skills, and experience with complex analysis of
quantitative and qualitative data.
B-0814 10:57
Q-elastography in the presurgical evaluation of thyroid nodules with
indeterminate cytology: bicenter experience on large population
V. Cantisani, M. Di Segni, N. Di Leo, C. Fioravanti, A. Rubini, P. Lodise,
C. Catalano, F. D'Ambrosio, P. Ricci; Rome/IT (
[email protected])
Purpose: To assess the role of Q-Elastography (Q-USE) in the
characterisation of thyroid nodules with indeterminate cytology (Thy3).
Methods
and Materials: 260 nodules in 220 patients (185 females; 75 male
patients) with Thy3 (mean age 50 years, range 18-78) were prospectively and
consecutively enrolled in two specialised University Centers. All patients
underwent multiparametric CDUS and Q-USE evaluation measuring the Strain
Ratio (SR) and then underwent surgery or FNAC. To evaluate the relationship
between categorical data and final histological outcome, univariate analysis
with the chi-square test and multiple logistic regression analysis was
performed. Sensitivity, specificity, positive predictive value, negative predictive
value and diagnostic accuracy were calcul ated. Cut-off value for strain ratio
was calculated by Receiver Operating Characteristic (ROC) analysis, with
Areas Under the Curve comparison with Bonferroni test. Histopathology was
the gold standard.
Results
Malignant nodules were 95; while the benign were 165 (18 adenomas
and 147 hyperplastic nodules). A higher Strain Ratio in malignant nodules than
benign ones was demonstrated, with an optimum SR cut-off equal to 2
obtained with ROC analysis. Hypoechogenicity, irregular margins and SR 2
showed accuracy of 69%, 80% and 91%, respectively. A multivariate analysis
showed a significant association between the SR and margins irregularity, thus
confirming the univariate analysis findings. The diagnostic accuracy of
hypoechogenicity (ROC area = 0.6725) was significantly lower than that of the
strain ratio (p,0.0001) and irregular margins (p = 0.0092).
Conclusion
Q-USE is a useful additional tool to Color-Doppler US in the
differential diagnosis of thyroid nodules with indeterminate cytology.
B-0816
11:06
A novel application: the role of ARFI sonoelastography for the diagnosis
of chronic autoimmune Hashimoto's thyroiditis
K. Hekimoglu, F. Yildirim, S. Arslan, A. Ozdemir, C.C. Demir, C. Yazici;
Ankara/TR
Purpose: The aim of this study was to prospectively assess the applicability of
real-time acoustic radiation force impulse (ARFI) sonoelastography in
diagnosis of chronic autoimmun thyroidi tis (CAT). This study revealed and
compared the thyroid tissue stiffness in patients with CAT with healty control
subjects (CS).
Methods
and Materials: The study group consist of 50 patients with first-
diagnosed CAT and 40 CS matched for age and gender. ARFI
sonoelastography was performed at 2-3 days before the exact diagnosis and
treatment initiation. In all patients with CAT and CS, 10 sonoelastographic
measurements were made in the everyone of thyroid lobe. Median values were
calculated for thyroid stiffness (TS) and expressed in meters/second (m/s). The
diagnostic performance of ARFI sonoelastography was evaluated using ROC
curves. Optimal cut-off values were chosen to maximise the sum of sensitivity
and specificity. Positive predictive va lue (PPV), negative predictive value
(NPV), and accuracy values were also calculated.
Results
TS assessed by means of ARFI in CAT patients (2.55 ± 0.32 m/s)
was significantly higher than in CS (1.63 ± 0.13 m/s) (P
< 0.0001). The optimal
cut-off value for the prediction of CAT was 2.03 m/s. For this cut-off value TS
had 85% sensitivity, 90% specificity , 92% PPV, 81% NPV, and 87% accuracy
for the presence of CAT.
Conclusion
ARFI sonoelastography seems to be useful method for the pre-
diagnosis assessment of CAT patients.
B-0817 11:15
Does new FDG-PET/CT64 show different uptake values than in previous
PET scans in thyroid incidentalomas (TI)?
R. Zalazar, M. Paramo, L. Sancho Rodriguez, M. Hernandez, J. Larrache,
J. Arbizu, M. Garcia Velloso, A. Villanueva; Pamplona/ES (
[email protected])
Purpose: Ultrasound fine needle aspiration cytology (USFNAC) has been
proved to be a useful tool in the characterisation of TI detected with FDG-PET
as well as new PET/CT64 devices show higher uptake than previous ones in
small lesions. The aim of the study is to determine whether TI characterised by
USFNAC and histology, detected with FDG-PET/CT64, FDG-PET/CT2 and
FDG-PET showed different standard uptake values (SUVmax)
Methods
and Materials: Sixty-five TI were studied with USFNAC,11 of them
with histology after thyroidectomy,54 were benign and 11 malignant.Fourteen
were studied with FDG-PET-(group1),37 with FDG-PET/CT2-(group2) and 14
with FDG-PET/CT64-(group 3).SUVmax was calculated and the values
obtained comparing the 3 devices. Data were expressed as mean ± S.D. T-
Test, ANOVA and non parametric tests were applied.
Results
SUVmax was 3.5 ±1.1 for group 1, 5.6 ±3 for group 2 and 6.9 ± 6.9 for
group 3 (p= 0.08).SUVmax for 54 benign lesions was 4.9 ±2.6 (range1.4-13.7)
and for 11 malignant lesions was 8.1 ±7.8 (range 2.2-26.4) (p=0.02). In group 1,
SUVmax for benign lesions was lower than for malignant ones (3.4 ±1.2 vs
3.9±0.5 p=NS), as well as in group 2 (5.4 ±2.4 vs 6.9± 5.9 p=NS) and in group
3 (4.9±3.5 vs 14.4±12.1 p=0.003).
Conclusion
SUVmax values of TI detected with FDG-PET/CT64 were higher
than those obtained with FDG-PET/CT2 and FDG-PET, with no significant
differences.Even though malignant TI presented significantly higher SUVmax
values than benign ones, some overlap was found, and these differences were
only detected by FDG-PET/CT64. FNAGUS is required to characterise TI
because there is overlap between benign and malignant lesions.
B-0818 11:24
Preoperative detection of parathyroid adenomas with 3 T MRI in patients
with hyperparathyroidism
B. Sacconi, R. Argirò, A. Iannarelli, E. d'Adamo, M. Rosignuolo, E. Romagnoli,
d. Cipriani, M. Bezzi, C. Catalano, D. Diacinti; Rome/IT
(
[email protected])
Purpose: To identify MRI features of parathyroid adenomas in patients with
primary hyperparathyroidism, using a fast protocol with a 3 T MR scanner.
Methods
and Materials: 22 patients with primary hyperparathyroidism with US
and Tc-99 sestamibi positive scans were enrolled and submitted to
preoperative MR scan. MRI imaging was performed on a 3 T unit using a
dedicated protocol: T2 IDEAL sequences on three-plane and axial T1 IDEAL
sequences before and after administration of 10 ml of gadolinium. The average
scan time was 16 minutes. Once the adenoma was identified, two radiologists
in consensus evaluated the presence of five features: hyperintensity,
homogeneous or marbled appereance and oblong shape on T2 IDEAL
sequence; cleavage plane from thyroid gland shown by "Indian Ink artefact" on
T2 outphase IDEAL; rapid enhancement in post-contrast T1-weighted images.
S313
BA C D E F G
Monday
Results
Radiologists identified adenomas as hyperintense on T2 IDEAL
sequence in 29/29 (100%), marbled in 23/29 (79.3%) and oblong in 26/29
(89.7%). "Indian ink artefact" on T2 outphase IDEAL was noticed in 23/29
(79.3%) and a rapid enhancement on T1-weighted sequence in 9/29 (31%).
Conclusion
This study demonstrates that some MR features recurs in high
percentage. In particular, we detected the hyperintensity in all cases; marbled
and oblong appereance on T2 IDEAL sequence and the presence of "Indian
ink artefact" on T2 outphase IDEAL were also frequently observed.
B-0819 11:33
The success of MRI in preoperative detection of primary
hyperparathyroidism focus and contribution to other imaging methods
V. Kaplanoglu, D. Ciliz, H. Kaplanoglu, U. Toprak, S. Parlak, B. Sakman,
E. Yuksel; Ankara/TR (
[email protected])
Purpose: Single parathyroid adenoma is the most common cause of primary
hyperparathyroidism (HPT). HPT focus should be detected before minimally
invasive surgery. Our aim is to investigate the success of magnetic resonance
imaging (MRI) and contribution of it to other imaging methods in detecting
primary HPT focus.
Methods
and Materials: One hundred fifty-nine parathyroid lesions of 150
patients, detected and pre-diagnosed by using MRI (159), ultrasound
(US)(159), 99mTc-MIBI scintigraphy (159), SPECT (73) and SPECT/CT (85),
proven pathologically after surgery, were evaluated retrospectively.
Results
Parathyroid lesions were classified as normal/ectopic location,
single/double, hyperplasia and reoperated lesions. Success ratios of imaging
techniques were calculated when they were used single and together with
others.When single or more imaging techniques were used for investigation of
parathyroid lesions, general sensitivity, sensitivity in ectopic lesions and double
adenomas, accurate detection rates of re-operated lesions are: MRI: 68.2%;
72.7%; 38.9%; 71.4%, US:80.3%; 54.5%; 50.0%; 42.8%, MIBI planar: 69.7%;
81.8%; 55.6%; 85.7%, SPECT: 68.4%; 80%; 62.5%; 50%, SPECT/CT: 86.5%;
87.5%; 81.1%; 100%, MRI+US: 90.2%; 81.8%; 72.2%; 100%,
MRI+MIBI:82.6%; 90.9%; 72.2%; 85.7%, MRI+SPECT: 80.7%; 80.0%; 75.0%;
71.4%, MRI+SPECT/CT: 87.8%; 87.5%; 81.8%; 85.7%, US+MIBI: 94.7%;
90.9%; 88.8%; 85.7%, MRI+US+MIBI: 96.2%; 100%; 94.4%; 100%,
MRI+US+MIBI+SPECT: 98.2 %; 100%; 100%; 100%,
MRI+US+MIBI+SPECT/CT: 97.3%; 100%; 100%; 100%, respectively.
Conclusion
Although MRI is not the first imaging technique in primary HPT
routinely, it increases the accuracy rates in the cases of insufficiency of US and
MIBI scintigraphy and particularly in detection of ectopic lesions, double
adenomas and re-operated parathyroid lesions, when used as additonal
imaging method.
10:30 - 12:00 Room F1
Oncologic Imaging
SS 1716
PET/CT as diagnostic and prognostic
biomarker
Moderators:
A. Pomoni; Lausanne/CH
N.N.
B-0820 10:30
The impact of PET-CT in detecting non-nodal extrathoracic metastases in
lung cancer compared to the staging CT
J.S.Z. Lee, K.M. Bradley, F. Gleeson; Oxford/UK (
[email protected])
Purpose: NICE Lung Cancer Guidelines 2011 recommend performing a PET-
CT after a staging CT prior to radical treatment. As CT detects mediastinal
lymphadenopathy and intervention determines its aetiology, the true value of
PET-CT is in detecting non-nodal extrathoracic metastases. The yield of PET-
CT in detecting non-nodal extrathoracic metastases has not been reported in
comparison to that of reviewing the prior staging CT.
Methods
and Materials: 235 consecutive lung cancer patients with no known
extrathoracic metastases referred for a PET-CT prior to radical therapy
underwent a contrast-enhanced neck, chest and liver CT and whole body PET-
CT.
Results
The median age was 72 years, 141 men (60%). Patients had stage Ia
(16%), Ib (19%), IIa (6%), IIb (7%), IIIa (25%), IIIb (6%) and IV (20%) disease.
The median interval between CT and PET-CT was 25 days (IQR, 18-29). 21
(9%) patients had 25 extrathoracic and extra-cerebral metastases. 9
metastases were identified on PET-CT and review of the prior staging CT. 16
metastases were invisible on the staging CT; 4 bone metastases were outside
the field of view, 6 had developed since referral (median interval 28 days; IQR,
19-39), and 6 were only identified on PET-CT.
Conclusion
PET-CT detects extrathoracic metastases which were missed or
invisible on the staging CT. Lung cancer patients should be offered a contrast-
enhanced pelvic CT in addition to the neck, chest, abdomen CT at staging to
increase the detection of extrathoracic metastases. An interval CT should be
performed if the PET-CT is delayed by greater than 30 days.
B-0821 10:39
Fluorodeoxyglucose positron emission tomography and chemotherapy-
related tumour marker expression in non-small cell lung cancer
X. Duan; Xi`an/CN (
[email protected])
Purpose: The chemotherapy resistance of non-small cell lung cancer (NSCLC)
remains a clinic challenge and is closely associated with several biomarkers
including epidermal growth factor receptor (EGFR), p53 and excision repair
cross complementing gene 1 (ERCC1). FDG-PET is the best non-invasive
surrogate for tumour biology with the maximal standardised uptake values
(SUVmax) being the most important paradigm. The purpose of this study was
to determine the correlation of chemotherapy related tumour markers with
FDG-PET SUVmax in NSCLC.
Methods
and Materials: FDG-PET SUVmax were calculated in patients with
NSCLC (n = 62) and immunohistochemical analysis was performed for EGFR,
p53 or ERCC1 on the intraoperative NSCLC tissues. The SUVmax difference
based on the histologic characteristics, gender, differentiation, grading and age
as well as correlation analysis among these parameters were performed.
Multiple stepwise regression analysis was further performed to determine the
primary predictor for SUVmax.
Results
The significant age, tumour size, p53 positivity or ERCC1 positivity-
dependent differences of SUVmax values were observed. The tumour
differentiation is significantly correl ated with SUVmax, tumour size, grading,
gender as well as the expression levels for p53 and ERCC1. Furthermore, the
expression level of p53 is significantly correlated with SUVmax and grading.
The FDG-PET SUVmax is also significantly correlated with cancer
differentiation. Furthermore, multiple stepwise regression analysis revealed
that p53 expression was the primary predictor for SUVmax.
Conclusion
The current study suggests that SUVmax of primary tumour on
FDG-PET might be a simple and good non-invasive method for predicting p53-
related chemotherapy resistance in NSCLC.
B-0822 10:48
Integrated PET-CT in patients with non-small cell lung carcinoma:
evaluation of equivocal mediastinal lymph nodes
F. Moloney, D. Ryan, L. McCarthy, M. Henry, M. Kennedy, J. McCarthy,
S. McSweeney, M.M. Maher, K. O'Regan; Cork/IE
(
[email protected])
Purpose: The aim of this study was to identi fy radiological factors that may
reduce false-positive results and increase diagnostic accuracy when staging
the mediastinum of patients with non-small cell lung carcinoma (NSCLC).
Methods
and Materials: This was a retrospective, interdisciplinary, per-node
analysis study. We included patients with NSCLC and mediastinal nodes with
an SUV max in the range of 2.5 to 4.0 kBq/ml on PET-CT. We hypothesised
that the greatest number of false positive cases would occur in this cohort of
patients.
Results
A total of 92 mediastinal lymph nodes were analysed in 44 patients.
Mediastinal disease (N2/N3) was histologically confirmed in 15 of 44 patients
and in 34 of 92 lymph nodes; positive predictive value of 37% and false
positive rate of 63%. Node SUV max, tumour size, ratio of node SUV max to
tumour SUV max (SUV node/tumour), and ratio of node SUV max to node size
(SUV node/size) were significantly higher in true positive cases. Using a
threshold of 0.3 for SUV node/tumour and 3 for SUV node/size yielded
sensitivities of 91% and 71% and specificities of 71% and 69%, respectively,
for the detection of mediastinal disease. Using both ratios in combination
resulted in a sensitivity of 65% and a specificity of 88%. Concurrent benign
lung disease was observed significantl y more frequently in false-positive
cases.
Conclusion
SUV node/tumor and SUV node/size may be complimentary to
conventional visual interpretation and SUV max measurement in the
assessment of mediastinal disease in patients with NSCLC.
B-0823 10:57
FDG PET-CT staging of breast cancer in young women
C.C. Riedl, E. Slobot, M.S. Jochelson, W.A. Weber, G.A. Ulaner; New York,
NY/US (
[email protected])
Purpose: To assess the impact of FDG PET-CT staging in female breast
cancer patients under the age of 40.
Methods
and Materials: In this IRB waived retrospective study, we screened
our Hospital Information System (HIS) for breast cancer patients < 40 years of
age who underwent staging PET-CT prior to any treatment at our instititution
between 2003 and 2012. To minimise sel ection bias, patients with symptoms
or conventional imaging findings suspici ous for extra-axillary nodal or distant
S314
BA C D E F G
Monday
metastases, and patients with prior malignancy were excluded. Metastases
found on PET-CT were confirmed by pathology in the majority of cases or by
follow-up imaging. Initial clinical stage was based on physical exam,
mammography, ultrasound and breast MRI. Relevant upstaging was defined
as PET-CT stage greater than initial clinical stage and higher than stage II. In
addition, incidental synchronous malignancies were recorded.
Results
Of 399 women identified in our HIS search, 134 met the inclusion
criteria. PET-CT findings lead to relev ant upstaging in 27 patients (20%),
including 1 of 20 (5%) with initial clinical stage I, 18 of 92 (20%) patients with
initial stage II, and 8 of 22 (36%) patients with initial stage III. Additionally, 4
thyroid and 1 rectal synchronous malignancies were found.
Conclusion
FDG PET-CT upstaged 20% of women < 40 years of age.
Although, current NCCN breast cancer guidelines include FDG PET-CT only
for stage III patients, these data suggest that women < 40 may benefit from
PET-CT staging even at stage II. A prospective study should verify these
findings.
B-0824 11:06
Imaging of prostate cancer biological relapse: our experience of MRI and
PET-CT comparison in the evaluation of bone and lymphnode metastases
and in detection of local recurrency
L. Cristiano, A. Bartoloni, R. D'Amico, G. Fioroni, R. Persechino, M. Tuccimei,
T. Lanzolla, F. Scopinaro, G. Argento; Rome/IT (
[email protected])
Purpose: Our aim was to compare the accuracy of 18 F-Choline PET-CT
versus MRI in the diagnosis of local recurrency, bone and lymphnode
metastases in prostate cancer. Appropriate imaging improves therapy and
follow-up in malignant recurrency and can lead radiation therapy (RT).
Methods
and Materials: We selected 32 patients reporting post-surgery and
post-radiotherapy increased PSA serum levels who had undergone both 18 F-
Choline PET-CT and T2W HR, DWI and DCE perfusional MRI.
Results
18 F-Choline PET-CT and MRI showed up prostate cancer local
recurrency in the same 22 patients. PET-CT showed up 8 suspicious
lymphnodes in 4 patients whereas MRI revealed 30 lymph nodes -mostly false
positive- in 16 patients (including those reported by the PET-CT). True positive
PET-CT lymph nodes were confirmed by PSA serum value < 0.1 ng/ml one
year after RT. Regarding bone metastases, PET-CT showed up 18 F-Choline
bone uptake in 80 areas suspicious for malignancy (mostly in the vertebrae) in
16 patients with a SUV borderline value. Among all the 80 areas showed up by
the PET-CT only 12 (in 8 patients) were confirmed by MRI.
Conclusion
PET-CT and MRI appeared to be equally accurate in revealing
prostate cancer local recurrency. PET is much more specific in the evaluation
of lymphnode metastases. In recognising bone metastases, PET-CT revealed
high sensitivity but low specificity (owing to the borderline SUV levels) whereas
MRI is more sensitive and specific. Therefore PET-CT an MRI image
integration seems to be the best choice in making more accurate diagnosis
and re-staging.
B-0825 11:15
The nature of incidental colonic FDG uptake at PET/CT
C. Keyzer, B. Dhaene, D. Blocklet, V. De Maertelaer, P. Gevenois;
Brussels/BE (
[email protected])
Purpose: To investigate the nature of incidental colonic focal FDG uptakes
and that of simultaneous lesions detected at colonoscopy but missed at
PET/CT.
Methods
and Materials: Among 9,073 patients scanned at PET/CT between
September 2008 and July 2012, 82 without history of colonic disease had focal
colonic uptakes and subsequent colonoscopy. Reading in consensus these
PET/CT examinations, a radiologist and a nuclear physician recorded the
location of uptakes and CT abnormalities, measured standardised uptake
value (SUV) and metabolic volume (MV), firstly not informed and secondly
informed about lesion location at colonoscopy. Records and measurements
were compared between histological types (benign, premalignant, or
malignant) of lesions detected at colonoscopy. ANOVA, logistic regression, t-
test, and Pearson's test were used.
Results
107 uptakes at PET/CT and 150 lesions at colonoscopy were
detected. Among 107 uptakes, 65 (61%) corresponded to a lesion at
colonoscopy (true positive) while 42 (39%) did not (false positive). Among 150
lesions at colonoscopy, 85 (57%) were non FDG-avid (false negative). MV of
true positive uptakes was lower than that of false positive ones (4.0 ±0.4 cm
3
vs. 6.16 ±0.7 cm3; p=0.006), but their SUVmax were not significantly different
(7.4±0.5 vs. 7.7±0.5; p=0.649). MV was the only variable predictive of a lesion
at colonoscopy (p=0.018). There was no difference in SUVmax or MV between
benign, premalignant, and malignant lesions (p ranging from 0.184 to 0.601).
Conclusion
Focal uptake can correspond to any histological type of colonic
lesions. Their detection should be followed by colonoscopy not restricted to the
zone housing the uptake.
B-0826 11:24
Assessment of recurrent peritoneal carcinomatosis with 18 F-FDG-
PET/CT in patients after cytoreductive surgery and hyperthermic
intraperitoneal chemotherapy
B.D. Klumpp, N. Schwenzer, S. Gatidis, I. Koenigsrainer, A. Koenigsrainer,
S. Beckert, M. Mueller, C.D. Claussen, C. Pfannenberg;
Tübingen/DE (
[email protected])
Purpose: In patients with peritoneal carci nomatosis (PC), cytoreductive
surgery with hyperthermic intraperitoneal chemotherapy (HIPEC) is an
approach with curative intention. Differentiation between posttherapeutic
findings and relapse of PC is challenging. We evaluated 18 F-FDG-PET/CT in
the follow-up to detect relapse of PC after HIPEC.
Methods
and Materials: 36 patients with recurring PC after HIPEC were
included (44 examinations). The examination included 3D 18 F-FDG-PET and
contrast enhanced CT. Images were assessed by two experienced readers
regarding the presence and the extent of PC using the peritoneal
carcinomatosis index (PCI). Imaging results were correlated with surgical
findings or follow-up.
Results
Relapse was suspected in 40 of 44 18 F-FDG-PET/CT examinations
341±269 days after HIPEC. PC was suspected in 237 of 572 peritoneal
segments. Relapse was missed by 18 F-FDG PET/CT in 4 patients and
significantly underestimated in 8 patient s. Diagnostic accuracy for the detection
of PC on patient base was 91%, sensitivity 91% and positive predictive value
100%. The correlation of imaging and surgical findings on segmental base
regarding the extent of PC was moderate (r=0.624). The mean PCI found by
PET/CT was 11.4 ±11.9 and by surgical exploration 16.6± 15.0. The extent of
PC was systematically underestimated by PET/CT (p < 0.05).
Conclusion
The diagnostic value of 18 F-FDG PET/CT after cytoreductive
surgery and HIPEC in the detection of recurring PC is good. However the
quantification of the extent of PC is limited due to post therapeutic tissue
alterations.
B-0827 11:33
The influence of 18 F-FDG PET/CT on therapy management of patients
with malignant melanoma stage III/IV: survival analysis after 5 years of
follow-up
S.-C. Schuele, C. Garbe, T. Eigentler, C. Pfannenberg;
Tübingen/DE (
[email protected])
Purpose: To evaluate the influence of 18 F-FDG-PET/CT on therapy
management and outcome of patients with stage III/IV melanoma.
Methods
and Materials: Patient-based re-evaluation of CT and 18 F-FDG-
PET/CT scans of 64 patients with advanced, primarily examined by a lesion-
based analysis (Pfannenberg et al. 2007). The cohort included 52 primary and
12 restaging examinations. For each patient, it was analysed if PET/CT caused
a change in therapy in comparison to the decisions based on CT alone.
Therapy modifications were classified in "major" (surgical vs. systemic therapy)
and "minor" (1
st line to 2 nd line chemotherapy). Patient's follow-up was
documented and 5-year survival rates were calculated.
Results
PET/CT resulted in a change of therapy in 54% of patients of the
entire group including "major" changes in 45%. PET/CT excluded distant
metastases in 8/64 patients primarily planned for metastasectomy based on
CT-scan. The highest number of shifts (59%) occurred in patients for primary
staging consisting of 52% major changes. The corresponding data for the
restaging group were 33% therapy changes (4/12 patients), thereof two
patients with a major shift. In 11/27 patients already scheduled for surgery
PET/CT revealed further metastases, making an operation futile. The 5-year
survival rate of the entire cohort was 30.1% with an increase to 33.6% in
primary staging and a reduction to 16.7% in restaging group.
Conclusion
FDG-PET/CT significantly infl uences therapy decisions in
patients with stage III/IV melanoma, especially for the proper selection for
complete metastasectomy, thereby increasing the long-time survival of this
patient group.
B-0828 11:42
18 F-FDG PET/CT for characterisation of peripheral nerve sheath tumours
in patients with neurofibromatosis type 1: intratumoral heterogenity of
tracer uptake as new parameter
J. Salamon, P. Bannas, J.D. Busch, J. Herrmann, G. Adam, V.F. Mautner,
T. Derlin; Hamburg/DE (
[email protected])
Purpose: The aim of this study was to evaluate the usefulness of intratumoural
tracer uptake heterogeneity on 18 F-fluorodeoxyglucose (FDG) PET/CT as
compared to a cut-off SUV max for characterisation of peripheral nerve sheath
tumours (PNSTs) in patients with neurofibromatosis type 1 (NF1). PNSTs may
undergo focal malignant transformation. Heterogeneity of tumour composition
is known a histopathological hallmark of malignant change. Malignant
peripheral nerve sheath tumours (MPNSTs) usually demonstrate increased
and inhomogenous tracer uptake.
S315
BA C D E F G
Monday
Methods
and Materials: 50 patients with NF1 underwent 18F-FDG PET/CT.
Intralesional 18F-FDG uptake was analysed by measuring the mean and
maximum standardised uptake value (SUV). Heterogeneity of tracer uptake
was evaluated using a SUV-based heterogeneity index (HI SUV) and qualitatively
graded using a three-point scale. Histopathologic evaluation as well as clinical
and radiological follow-up served as reference standard.
Results
Both, HI
SUV and SUV max could identify malignant tumours with a
sensitivity of 100%. Qualitative intratumoural uptake heterogeneity and
malignant transformation in peripheral nerve sheath tumours showed a
significant association (p < 0.0001). MPNST showed a significantly larger HI SUV
compared to benign tumours (p=0.0002). Cohen`s 5 was 0.86 for interrater
agreement and 0.88 for intrarater agreement on heterogeneity.
Conclusion
MPNSTs in patients with NF1 reveal strong intratumoural
heterogeneity of tracer uptake in 18 F-FDG PET/CT. Either a SUVmax cut-off
value or a heterogeneity index can identify malignant PNSTs with a sensitivity
of 100%. The SUV
max approach using a cut-off value leads to a higher
specificity. There is no significant improvement in diagnostic performance
using both methods in combination.
B-0829 11:51
The value of F18-FDG PET/CT in the diagnosis of CUP syndrome: a
retrospective study
I. Sacarea, F. Weber, S. Maune, J. Wustrow, A. Zöllich, J. Müller-Hübenthal;
Cologne/DE (
[email protected])
Purpose: Metastatic cancer without a primary site is known as cancer of
unknown primary (CUP Syndrome). We distinguish between head/neck
tumours (mostly squamous) and tumours of the whole body (usually
adenocarcinomas). The life expectancy of these patients may increase by
proper identification of the original tumour and consequent adapted therapy.
The aim of this analysis is to show the value of F18-FDG PET/CT in the
diagnosis of primary tumours in comparis on to conventional diagnostics based
on the database of Praxis in KölnTriangle, Germany.
Methods
and Materials: Between 2008 and 2013 out of a total of 2800 cases,
we performed 134 F18-FDG PET/CTs for 116 patients (56 male/60 female,
median age 61y). with CUP Syndrome. So far, 59 cases (44%) were tracked
(medical letters, histology, therapeuti c approach). Conventional diagnostics
(CT, MRI, scintigraphy, panendoscopy) was primarily performed in almost all
patients.
Results
We could identify a possible primary in 80 cases (59.7%), 70 cases
additional to conventional diagnostics. In head/neck tumours, the primary was
most commonly found in the nasopharynx and tonsils (34.6%, resp. 23.07%).
Whole-body tumours were found mostly in the lungs (38.8%) and the
gastrointestinal tract (20.37%). Unknown metastases have been identified in
50 cases (37.3%). For head/neck tumours, the examination-related sensitivity
for the detection of primary tumours was 90% and the specificity was 85%. For
whole-body tumours, these values were 93%, respectively 88%.
Conclusion
The F18-FDG PET/CT can identify additional primary tumours
and metastases in 52% of cases when compared to conventional diagnostics
and facilitate possible life-prolonging therapy.
10:30 - 12:00 Room F2
Breast
SS 1702
Breast density and general breast MRI
Moderators:
R.M. Pijnappel; Utrecht/NL
K. Pinker-Domenig; Vienna/AT
B-0830 10:30
Fully automated breast density measures and breast cancer risk: a case-
control validation study
M. Abdolell, K.M. Tsuruda, S.E. Iles, C.B. Lightfoot, J.I. Payne, J. Caines;
Halifax, NS/CA (
[email protected])
Purpose: Legislation requiring reporting of breast density to women has been
enacted and endorsed across the US. The current standard of care for breast
density assessment is visual assessment by radiologists applying the
American College of Radiology (ACR) BI-RADS density lexicon. However, the
ACR has indicated that BI-RADS assessments are not reproducible and no
longer endorses its use. Automated breast density measurement software
provides such reproducible measures of density, but must be clinically
validated.
Methods
and Materials: A case-control study (n=1287), frequency matched
(1:2) on 5-year age-group at screen, was conducted using data from the Nova
Scotia Breast Screening Program and Capital District Health Authority (Nova
Scotia, Canada). Logistic regression was used to model the association
between mammographic density and breast cancer risk, controlling for age,
first-degree family history of breast cancer, menopausal status, number of
births and HRT use at time of screen. Percent density was measured from
single digital MLO views using Densit as (Densitas Inc)., an automated
mammographic density assessment software.
Results
Cases and controls were similar number of births, HRT use,
menopausal status and family history. Controlling for these risk factors, women
with 75% density had a significantly increased risk of breast cancer compared
to women with 25% mammographic density [odds ratio 3.58 (1.7, 7.4)].
Conclusion
The results from this study show that breast density measured
using Densitas' automated breast density software is similarly associated with
breast cancer risk as visually assessed breast density measured by
radiologists.
Author Disclosures:
M. Abdolell: Founder; Densitas Inc. Patent Holder; Densitas Inc. K.M.
Tsuruda: Employee; Densitas Inc.
B-0831 10:39
Very low mammographic breast density predicts poorer outcome in
patients with invasive breast cancer
A. Masarwah, P. Auvinen, M. Sudah, S. Rautiainen, A. Sutela, O. Pelkonen,
R. Vanninen; Kuopio/FI (
[email protected])
Purpose: To examine the prognostic value of mammographic breast density
(MBD) and tumor features and their relationship with established prognostic
factors in selected patients with invasive breast cancer.
Methods
and Materials: This study is based on a database of 278 breast
cancer patients treated in Kuopio University Hospital during 2002-2008.
Altogether 139 consecutive HER2-positive breast cancer patients were first
selected and subsequently complemented with HER2-negative patients
(n=139) matched for age and time of operation. Mammograms were analysed
in consensus by 5 radiologists to evaluate tumor features and MBD according
to the Breast Imaging Reporting and Data System (BI-RADS). Breast density
was dichotomized into Very Low Density (VLD; BI-RADS 1) or Mixed Density
(MID; BI-RADS 2+3+4). Mammographic features were then compared with
established prognostic factors and outcome of the patients.
Results
50 deaths occurred during the follow-up time, of which 40 (14.4%)
were from breast cancer. Patients with VLD breasts had a significantly worse
prognosis compared to patients with MID breasts (disease free survival 75.6%
vs. 90.7%, p 50
years). No other mammographic feature was prognostically significant. In Cox
regression analysis VLD proved to be an independent poor prognostic feature
second only to HER2 positivity.
Conclusion
Previously, high breast density has been shown to be a
significant risk factor for breast cancer . However Very Low Breast Density is
associated with poorer outcome.
B-0832 10:48
Geographical variation in mammographic density distribution in the
Netherlands
D. van der Waal1, C.H. van Gils2, M.J.M. Broeders1, G.J. den Heeten1;
1Nijmegen/NL, 2Utrecht/NL (
[email protected])
Purpose: Mammographic density is related to screening sensitivity.
Differences in breast density distribution between populations may thus explain
part of the variation in regional screening performance. The aim of this study
was to determine whether regional differenc es in breast density distribution are
present in the Netherlands.
Methods
and Materials: As part of the DENSE trial, density profiles of
unprocessed mammograms were collected from screening units. The regions
in our study were based on the geographical coverage of 13 radiology groups.
In total, 149,167 screening examinations between 2012 and 2013 were
included. Volumetric breast density was determined using the fully-automated
software Volpara (M +takina Technology, New Zealand). Three breast density
measures were studied, namely: dense tissue volume (in cm3), percent density
(in %), and the Volpara Density Grade (VDG; categories 1-4).
Results
The distribution did appear to vary between the regions. The highest
density was observed in the middle of the country, with a geometric mean
percent density of 7.86 (95%CI: 7.81-7.90) and 9.6% of the examinations
classified as VDG4. In the lowest breast density region, the geometric mean
percent density was 6.56 (95%CI: 6.44-6.69) and 6.3% of the exams were
classified as VDG4. Preliminary analyses showed that the effect of age-
adjustment was limited. Analyses on potentially explanatory variables like
socio-economic status (SES) and breast cancer incidence will be presented at
the conference.
Conclusion
The preliminary results suggest that geographical variation in
mammographic density distribution is present in the Netherlands, which would
support structural assessment of breast density within the screening
programme.
S316
BA C D E F G
Monday
Author Disclosures:
C.H. van Gils: Other; Principal investigator of the DENSE trial. Matakina has
provided the Volpara software licenses for this trial. Bayer Health Care
provides a financial contribution for the DENSE trial. G.J. den Heeten:
Advisory Board; Former member of the medical advisory board of Matakina.
B-0833 10:57
Volumetric breast density: can computer assessment really reduce
human variability?
G. Gennaro, E. Baldan, E. Bezzon, C. Dal Bosco, I. Polico, A. Proietti,
L. Pescarini; Padua/IT (
[email protected])
Purpose: To verify if breast density assessment computer-based can reduce
inter-reader variability for women with dense breasts.
Methods
and Materials: 2103 consecutive patients from a diagnostic
population who underwent bilateral digital mammography in two views between
Jan and Mar 2013 were included in the study. Volumetric breast density (VBD)
calculated by Volpara 1.4.3 was compared with the BIRADS scores assessed
by six breast radiologists independently. Inter-reader variability was evaluated
using kappa statistics, and the subset of dense breasts (classified by each
reader as BIRADS 3 and 4) was further analyse, comparing individual
agreement/disagreement versus the majority of readers.
Results
The overall kappa across the readers was 0.56, associated to a
moderate agreement. However, the mean absolute agreement between
individual readers and the majority was 81.0%. In particular, cases for which
the individual readers assigned a BIRADS 3 while the majority was 4 and vice
versa, ranged from 3.1% to 8.7%, leading to a mean by 6.4%. Mean VBD for
those cases was between 18.12% to 21.34% depending on the reader. The
VBD distributions were overlapped with the distributions of VBD for cases of
total agreement (either BIRADS 3 or 4) for 3 out of 6 readers, indicating that
the threshold between BIRADS 3 and 4 is not the same across the readers.
Conclusion
Volumetric breast density computer-based can remove inter-
reader variability in categorisation of dense breasts and following decisions
about patient workup.
B-0834 11:06
Breast density percentage assessment using a 3 T MRI system:
comparison amongst sequences using IDEAL (iterative decomposition of
water and fat with echo asymmetry and least squares estimation)
sequences as reference standard
A. Tagliafico, B. Bignotti, D. Astengo, L. Martino, A. Signori, G. Taglaifico,
M. Calabrese; Genoa/IT (
[email protected])
Purpose: There is no standardised method to evaluate breast density. IDEAL
(iterative decomposition of water and fat with echo asymmetry and least
squares estimation) sequences permit a differentiation of breast tissue
composition on MRI. We used this sequence as a reference standard to
compare breast density percentage evaluated on standard MRI sequences.
Methods
and Materials: The study was approved by the Local Ethics
Committee (National Institute for Cancer Research) and written informed
consent was obtained from participati ng women. MRI examination was
performed in 48 consecutive patients (mean age 41, years; range, 35-67
years) on a 3.0 T scanner with a dedicated eight-channel bilateral breast coil.
MRI protocol included: T1-turbo spin-echo (T1-tSE), T2-turbo spin-echo (T2-
tSE), IDEAL and VIBRANT (volume imaging for breast assessment) before and
after injection of contrast media. Breast density was calculated with a semi-
automated software. Statistical analysis was performed with non-parametric
tests as appropriate.
Results
Mean percentage of breast density calculated in each sequence was:
T1-tSE = 56%; T2-tSE = 52%; IDEAL Fat Only = 55%; IDEAL Water Only =
53.46%, VIBRANT = 54.85%. Significant differences were observed between
T2-tSE and both T1-tSE (p < 0.001), VIBRANT sequences (p = 0.009), T1-tSE
and both IDEAL Water Only (p = 0.007) and IDEAL Fat Only (p = 0.047).
Breast density percentage showed a positive linear correlation amongst
different sequences: r0.93.
Conclusion
Differences amongst MRI sequences used to assess breast
density percentage exist. T1-weighted sequences showed the more similar
breast density percentage values to IDEAL Water Only sequences used as
Reference
standard.
B-0835 11:15
Visual and automated volumetric assessment of mammographic density
(MD): do measurements depend on the digital mammography unit?
S.J. Vinnicombe, A.J. Evans, K. Hart, P. Whelehan; Dundee/UK
(
[email protected])
Purpose: Full field digital mammography (FFDM) fac ilitates automated
volumetric measurement of mammographic density (MD), a potent risk factor
for breast cancer. It is unknown if there are systematic differences between MD
measurements derived from mammograms acquired on different vendor units.
This work aimed to assess this using a commercially available volumetric tool.
Methods
and Materials: IRB approval was waived for this retrospective study
of anonymised images. Mammograms from 100 subjects obtained on GE
Senographe™ and Hologic Selenia™ units 1 year apart were studied. Percent
volumetric density was measured with Volpara™. For comparison, two
experienced observers with proven excellent intra- and inter-observer reliability
visually assessed MD, blinded to manufacturer, using ACR BI-RADS scoring
and a percentage scale. Agreement between paired scores was tested using
intraclass correlation coefficients and Cohen's kappa.
Results
Agreement between paired scores was excellent for all methods
(ICC/kappa all > 0.9, p < 0.001). For Volpara, mean absolute difference
between paired scores was 0.67% (95% CI -0.17% - 1.16%), ~8% of the
median Volpara score (8.4%). No syst ematic bias was identified. 10% of
BIRADS paired scores disagreed and higher scores were assigned to
Senographe mammograms in 85%. Visual percentage scores were statistically
significantly higher for Senographe mammograms in 79% of cases (Chi2,
p < 0.001).
Conclusion
Variances between volumetric MD measurements using
Volpara™, obtained from GE Senographe and Hologic Selenia mammograms
in the same women one year apart, were small and equally distributed in both
directions, whereas human visual densit y scores were statistically significantly
more likely to be higher in Senographe mammograms.
B-0836 11:24
Breast MRI and false negative invasive ductal carcinoma at our
department
G. Trecate, R. Agresti, B. Valeri, M. Sandri, M. Capalbo, C. Ferranti,
D. Vergnaghi, G. Scaperrotta, P. Panizza; Milan/IT
(
[email protected])
Purpose: High sensitivity of MRI in breast cancer (BC) diagnosis is known to
be supported by angiogenesis, which is responsible of the early uptake of
gadolinium. The aim of this study was to analyse the inner architecture of some
invasive carcinoma (IC) that didn't correspond to this semeiotic basis.
Methods
and Materials: Between 2009 and 2012 we staged 194 BC, 4 of
which not combined with contrast-uptake. Histology revealed IC, triple-negative
status, grading3, proliferative index > 60%. We compared these 4 cases with
12 consecutive BC with the same biology but normally enhancing at MRI.
Results
Pathology revealed in all non-enhancing BC a common pattern of
densely stuffed cells, with and an epithelial-stroma ratio prevalent for cells. For
the non-enhancinc BC the cell number average was 120x10hpf (high-power-
field), while in the normally-enhancing BC this average was 47xhpf (p=0.0036
Wilcoxon test).
Conclusion
False negative results due to the non-uptake of gadolinium are
mainly described for in situ carcinoma. Non enhancement for IC is conversely
very rare. Since the biodistribution of gadolinium foresees a transition from
peripheral vessels into extracellular space, a possible explication of the low
uptake can be related to a mechanic phenomenon given by the numerosity of
the cells compared with the lack of the stroma. The clinical relevance of this
phenomenon is that if gadolinium can't reach these neoplasm, even for
chemotherapy it could be difficult to target them. For this subgroup of BC, MRI
imaging can thus become a predictive indicator of the sensibility to some
specific therapies.
B-0837 11:33
Differentation of ductal carcinoma in situ (DCIS) vs fibrocystic breast
disease using breast MRI: new insights on imaging patterns and
diagnostic accuracy
M. Dietzel
1, W.A. Kaiser2, P.A.T. Baltzer3; 1Erlangen/DE, Jena/DE, 2Jena/DE,
3Vienna/AT, Jena/AT (
[email protected])
Purpose: In breast-MRI one very frequent cause for false-positive DCIS
diagnoses remains fibrocystic breast disease (FBD). Surprisingly, there is little
systematic data on the characteristic imaging-patterns of FBD and its
differentiation from DCIS. This breast-MRI study aims to identify typical
appearances of both entities and to in vestigate accuracy for the differentiation
of DCIS from FBD.
Methods
and Materials: Consecutive patients receiving breast-MRI
(standardised-protocols: dynamic-T1w-GRE before/after Gd-DTPA
[0.1 mmol/kgBW]; T2w-TSE) with subsequent pathological-sampling were
investigated. 16 previously published breast-MRI descriptors were
prospectively assessed by two experienced radiologists in consensus ( > 500
MRM-examinations; blinded to pathology). All patients showing DCIS (n=76) or
FBD (n=219) were evaluated statistically: Univariate- and multivariate statistics
were performed to identify accuracy of single descriptors, accuracy of
descriptor-combinations, as well as overall-accuracy of breast-MRI for the
differential-diagnosis of FBD vs. DCIS ( <
2-statistics; CHAID-tree: area-under-
the-ROC-curve[AUC]; Bonferroni-correction).
S317
BA C D E F G
Monday
Results
5 (31%) breast-MRI descriptors significantly differentiated DCIS form
FBD ( Pcorrected< 0.05). Highest accuracy was identified for "Wash-in" (Odds-
ratio/OR=5.7), "Blooming-sign" (OR=3.4), "Wash-out" (OR=3.2) and "Adjacent-
vessel-sign" (OR=3.0). Performance of single features could be improved, if
multiple descriptors were applied in combination, e.g.: presence of "wash-in
(weak)" & "oedema (absent or diffuse)" was highly typical of FBD (OR=22.8),
whereas presence of "wash-in (intermediate or strong)", "shape (irregular)" and
"blooming-sign" was characteristic of DCIS (OR=6.4). Overall accuracy of
breast-MRI for the differential-diagnosis of DCIS vs. FBD revealed AUC=0.75
(cross-crossvalidated sample).
Conclusion
We identified typical breast-MRI features of DCIS and FBD. Such
showed significant potential to differentiate both pathologic entities, particularly
if they were used in combinations.
B-0838 11:42
Inflammatory breast disorders - benign vs malignant: does T2-weighted
magnetic resonance sequence (MRI) meet this diagnostic challenge?
I.F. Kamal, R.M.K.E. Fouad, S.M. Mansour, L.A. Salaheldin, S.T. Hamed,
O.S. Omar; Cairo/EG (
[email protected])
Purpose: The purpose of the study is to assess the role of T2-weighted MRI
sequence in discriminating benign from malignant inflammatory breast
disorders.
Methods
and Materials: The study included 90 patients presenting with signs
of mastitis. They were subjected to MRI examinations. Lesions were classified
as of bright, intermediate or of low signal intensity. The presence of collections
and skin thickening were reported. Biopsy was performed. Pathology results
were correlated with the postulated MRI diagnosis. Measures of diagnostic
accuracy were then calculated.
Results
According to pathology reports, 60 (66.7%) cases were benign and
30 (33.3%) cases were malignant. Bright T2 signal correlated with benign
pathologies (53/60, 88.3%) and dark T2 signal (26/30, 86.66%) correlated with
malignant ones (P value=0.018). Presence of ill-defined collections (56/60,
93.3%) was significantly higher in benign cases (P value=0.001). A cut off
value of skin thickness 5 mm was considered indicative of malignancy (area
under ROC 0.668). The overall calculated sensitivity, specificity, PPV, NPV and
efficacy of MRI based on the T2 WIs findings were 86.7%, 96.67%, 92.86%,
93.55% and 93.33%, respectively.
Conclusion
In this study, we verified the role of T2 WIs in differentiating
between benign and malignant forms of mastitis. T2W MRI images should be
incorporated in the diagnostic work up of mastitis patients especially in cases
that are resistant to medical treatment. Bright T2 signal, ill-defined collections
and mild skin thickening were considered indicative of benign lesions. Dark T2
signal, absence of collections and extensive skin thickening were considered
as indicative of malignant lesions.
B-0839 11:51
A rim-enhanced mass with central cystic changes on MR imaging: how to
distinguish breast cancer from inflammatory breast diseases?
L. Wang, D. Wang; Shanghai/CN (
[email protected])
Purpose: To evaluate the capacity of magnetic resonance imaging (MRI) to
distinguish breast cancer from infla mmatory breast diseases manifesting a rim-
enhanced mass with central cystic changes.
Methods
and Materials: Forty cases of breast cancer and 52 of inflammatory
breast diseases showing a rim-enhanced mass with central cystic changes
were retrospectively reviewed. All cases underwent dynamic contrast-
enhanced MRI and 31 of them underwent diffusion-weighted imaging (DWI).
Morphological features, dynamic parame ters and apparent diffusion coefficient
(ADC) values were comparatively analysed using univariate analysis and
binary logistic regression analysis.
Results
The mean age of breast cancer was older than that of the
inflammatory disease group (55.4 years vs. 44.5 years, P < 0.001). Breast
cancer had a significantly thicker wall than the inflammatory diseases
(P < 0.001), while internal enhancing septa were more common in
inflammatory diseases (P=0.003). On DWI, 86.7% of breast cancers showed a
peripheral hyperintensity, whereas 93.8% of inflammatory breast diseases had
a central hyperintensity (P < 0.001). Compared to the inflammatory diseases,
breast cancers had a lower ADC value for the wall (1.02×10
-3 mm2/s vs.
1.45×10-3 mm2/s, P=0.001) and a higher ADC value for the cavity (1.93×10 -
3 mm2/s vs. 1.01×10-3 mm2/s, P < 0.001).
Conclusion
Both breast cancer and inflammatory breast disease could
present as a rim-enhanced mass with central cystic changes on MRI.
Integrated analysis of the MR findings can allow for an accurate differential
diagnosis.
10:30 - 12:00 Room G/H
Genitourinary
SS 1707
Imaging of the kidney: an update
Moderators:
M.-F. Bellin; Le Kremin-Bicêtre/FR
J.J. Fütterer; Nijmegen/NL
B-0840 10:30
Assessment of renal function with unilateral ureteral obstruction using
320-detector MDCT
X.-R. Cai, J. Yu, Z.-H. Xian, W.-C. Yang; Guangzhou/CN (
[email protected])
Purpose: To investigate the renal cortical and medullary perfusion changes
associated with unilateral ureteral obstruction (UUO) using 320-detector
MDCT.
Methods
and Materials: This study included 64 patients with UUO. According
to the hydronephrosis severity, they were divided into three groups: mild,
moderate and severe group. The 320-detector row CT scanner enabled renal
perfusion CT without table movement. Perfusion was calculated using the
maximum slope and Patlak model. The mean cortex and medulla perfusion of
healthy and diseased kidneys were compared.
Results
Mean cortical and medullary blood flow (BF), blood volume (BV) and
clearance statistically decreased from the mild group to the moderate group to
the severe group (p < 0.05). An inverse correlation was observed between
cortical BV, BF, clearance, medullary clearance and hydronephosis severity
(r=-0.270, p=0.004; r=-0.474, p=0.000; r=-0.515, p=0.004; r=-0.329,p=0.001,
respectively). Compared to the healthy kidneys, the mean cortical BF, BV and
clearance in the severe group were found to have a statistically significance
(p 0.05).
Conclusion
320-Detector MDCT makes it possible to conduct perfusion
measurements of the whole kidney. Our preliminary results suggested that
estimated perfusion values have the po tential to be used for evaluation of UUO
renal injury.
B-0841 10:39
Renal sinus fat invasion in renal cell carcinoma: evaluation of
multidetector computer tomography (MDCT) predicting factors
A. Lebovici
1, M. Buruian2, D.S. Feier1, A. Tamas-Szora1, M.D. Suciu1,
S.A. Sfrangeu1; 1Cluj-Napoca/RO, 2Targu-Mures/RO
(
[email protected])
Purpose: To determine imaging factors of MDCT that are able to predict renal
sinus fat invasion in patients with renal cell carcinoma (RCC).
Methods
and Materials: A total of 113 patients (84 males, mean age 57.4± 12
years) with RCC (91 clear cell, 15 chromophobe, 4 papillary, 2 collector duct, 1
translocation) who underwent multiphase contrast-enhanced 64-MDCT and
partial or radical nephrectomy were included in this retrospective study.
Detection of enhanced nodules in the renal sinus fat, maximum tumor
dimensions, the ratio between intra- and extrarenal tumor diameter, the
absence of a pseudo-capsule and vascular invasion were considered
predictors of histologically confirmed renal sinus fat invasion.
Results
In multivariate logistic regression analysis, enhanced nodules, the
ratio between intra- and extrarenal tumor diameter < 0.4 and vascular invasion
were the only independent predictors of renal sinus fat invasion (p < 0.0001).
The detection of an enhanced tumor nodule in renal sinus fat alone, is able to
predict the invasion with an AUROC of 0.75 (Se=60%, Sp=91%). Adding the
vascular invasion quantification and a rati o between intra- and extrarenal tumor
diameter < 0.4, increases the diagnosis value to an AUROC=0.85 (Se=83%,
Sp=81%), with 79.56% correctly classi fied patients according to histology
reports.
Conclusion
Our data suggest that the detection of an enhanced nodule,
together with vascular invasion and a ratio between intra- and extrarenal tumor
diameter < 0.4 are better predictors of histologically confirmed renal sinus fat
invasion than the presence of an enhanced tumor nodule alone.
S318
BA C D E F G
Monday
B-0842 10:48
Estimation of postoperative renal function through virtually calculated
renal cortical volume on CT in patients undergoing total nephrectomy
S.-H. You, D. Sung, N. Han, B. Park, M. Kim, S. Cho; Seoul/KR
(
[email protected])
Purpose: The purpose of our study was to estimate the postoperative renal
function through the virtually calculated renal cortical volume measured by
preoperative CT in patients undergoing total nephrectomy.
Methods
and Materials: A total of 105 patients undergoing MDCT and total
nephrectomy for kidney donation (n=65) or renal mass (n=40) were included in
this study. The preoperative CT was assessed to measure the volume (cm 3) of
both kidneys using the software that automatically contours the renal cortex.
Estimated glomerular filtration rate (eGFR, ml/min/1.73m
2) was measured after
operation. Statistical analysis was done using the linear mixed-effects models
(MIXED) procedure in SPSS.
Results
Renal volume measurements yielded a mean virtual pre- and
postoperative renal cortical volume of 254.2 and 125.6, respectively.
Preoperative mean eGFR was 72.3, and postoperative eGFR was respectively
61.7, 71.4 and 69.3 at 6, 12 and 18 months after operation. The MIXED
procedure revealed that the reason of operation (donation or tumor), gender,
HTN, proteinuria, weight, age, virtual preoperative, postoperative, removed
renal cortical volume and the time after operation correlate significantly with the
eGFR. Especially, the reason of operatio n, virtual preoperat ive renal cortical
volume and the time after operation are more important factors for predicting
postoperative eGFR (p < 0.001).
Conclusion
Renal cortex volume measured on CT can allow the prediction of
renal function. Postoperative eGFR ma y be estimated by the virtual renal
cortical volume calculation.
B-0843 10:57
Renal transplantation: 3D quantification of perfusion defects using
contrast enhanced ultrasound, and its clinical significance
B. Stenberg, M.A.F. McNeill, S.T. Elliott; Newcastle Upon Tyne/UK
(
[email protected])
Purpose: Nearly 3000 renal transplants are performed annually in the UK,
following which it is common practice to obtain a Tc-DTPA renogram to assess
perfusion of the graft. Although this provides functional information,
disadvantages include its use of ionisi ng radiation coupled with low spatial
resolution, whilst being both time consuming and costly. We suggest that
contrast enhanced ultrasound (CEUS) would provide a quick, cost efficient,
high resolution, accurate alternative.
Methods
and Materials: 97 renal transplants underwent both CEUS and Tc-
DTPA after surgery. Tc-DTPA was performed in the nuclear medicine
department with a standard dose of 150mBq over at least 10 minutes of
screening. CEUS consisted of 2.4 ml Sonovue IV contrast, with 60 seconds
continuous capture and 3D acquisition. 3D CEUS was analysed using QLab
software. Patient renal function was monitored for 3 months post-operatively.
Results
Tc-DTPA detected 9 perfusion defects of varying sizes. CEUS
detected all of these plus an additional 14 defects not identified on Tc-DTPA.
Further analysis comparing perfusion defect against serum creatinine and
eGFR demonstrates a positive correlation between the presence and size of
the defect and degree of subsequent renal dysfunction.
Conclusion
CEUS is an accurate examination for detecting renal transplant
perfusion defects. Due to high spatial and temporal resolution, CEUS will
identify a significant number of ad ditional defects not seen on standard
renogram imaging. With the quantification of these perfusion defects, valuable
prognostic information can be obtained to predict the degree of subsequent
renal dysfunction influencing future clin ical decision making and informing
functional expectation.
B-0844 11:06
Differentiation of small (<< 4 cm) angiomyolipoma with minimal fat from
non-clear cell renal cell carcinoma on biphasic MDCT
S. Woo, J. Cho, S. Kim, S. Kim; Seoul/KR (
[email protected])
Purpose: To evaluate quantitative biphasi c MDCT features that differentiate
between small AMLmf and NCCRCC, and to integrate them to develop a
simple and easy diagnostic algorithm.
Methods
and Materials: This study was IRB-approved; informed consent was
waived. Biphasic MDCT images of pathologically proven AMLmfs (n= 24) and
NCCRCCs (n = 55) of 79 patients were evaluated. Age, sex, size, long-to-short
axis ratio (LSR), attenuation and enhancement degree in all phases,
precontrast tumour-kidney attenuation difference (PTKAD) in Hounsfield units
(HU) were compared with Chi-square analysis, independent-samples t-test,
ROC curves. A criterion was formulated with classification and regression tree
analysis (CART). Thereafter, CART-based algorithm was tested with additional
interpretations from two radiologists. Intra- and inter-observer variability was
analysed with Bland-Altman analysis.
Results
LSR was greater in AMLmf than NCCRCC (p < 0.001). AMLmf
showed higher attenuation (all phases), CMP enhancement and washout than
NCCRCC (p 0.001). PTKAD was greater in AMLmf than NCCRCC
(p 7.5 HU, LSR > 1.23) predicted AMLmf with sensitivity,
specificity, PPV, and NPV of 87.5%, 96.4%, 91.3%, and 94.6%. Mean intra-
/inter-observer difference was -0.1 HU/0.03 and -1.0 HU/0.09 for PTKAD/LSR,
respectively. These interpretations changed the final diagnosis in 1.3% (1/79)
and 5.1% (4/79) patients for radiologists 1 and 2.
Conclusion
Biphasic MDCT was useful for differentiating AMLmf and
NCCRCC. CART-based algorithm using PTKAD > 7.5 and LSR > 1.23 was
simple and accurate in predicting AMLmf.
B-0845 11:15
Assessment of diffusion parameters of the kidney over the entire cardiac
cycle using ECG-triggered, time-resolved diffusion-weighted imaging
(DWI)
R.S. Lanzman, P. Heusch, J. Weller, A. Müller-Lutz, F. Miese, P. Kröpil,
G. Antoch, H.-J. Wittsack;
Düsseldorf/DE (
[email protected])
Purpose: To assess changes in renal diffusion properties over the entire
cardiac cycle using ECG-gated, time-r esolved diffusion-weighted imaging
(DWI).
Methods
and Materials: 20 healthy volunteers (10 males, 10 females,
26.2 ± 7.2 years) were investigated on a 1.5 T MR scanner. Blood flow within
the renal arteries was determined by ECG-gated phase contrast (PC) flow
measurements. For time-resolved renal diffusion weighted imaging (DWI), an
ECG-gated and respiratory-triggered coronal single-slice EPI-sequence was
acquired at 14 defined time points over the cardiac cycle
(20.70,120,.,620,720 ms after R-wave) using the following parameters: 4 b-
values (0, 50, 100, 300 s/mm2), 3 directions, TR/TE =3000 ms/66 ms,
FOV=400 mm2, MxP =192x192, slice thickness 6 mm. ROI measurements
were performed and an ADC pulsatility index (PIADC) was defined as
normalised maximal change in ADC values within the cardiac cycle
(ADXmax/ADCmin).
Results
Minimal renal blood flow velocity was 16.9 ± 5.6 cm/s at the time-
point of the R-wave raising to a maximum of 40.4 ± 10.6 cm/s about 142 ms
after the R-wave (p < 0.05). Minimal mean ADC value was 2145 ± 107 x 10-
6 mm²/s at the time-point of the R-wave and maximum mean ADC was
2766 ± 213 x 10-6 mm²/s 138 ms after the R-wave (p < 0.05). Mean ADC
pulsatility index in the renal cortex was PIADC = 1.30 ± 0.06.
Conclusion
Renal ADC values exhibit pulsatile characteristics over the
cardiac cycle, enabling calculation of an ADC pulsatility index. Further studies
are required to determine the diagnostic value of the ADC pulsatility index in
patients with renal pathologies.
Author Disclosures:
G. Antoch: Speaker; Siemens Medical Solutions, Bayer Healthcare, BTG.
B-0846 11:24
Diffusion-weighted magnetic resonance imaging of kidneys in healthy
volunteers and living kidney donors
K. Sulkowska, P. Palczewski, M. Golebiowski; Warsaw/PL (
[email protected])
Purpose: Despite promising reports on diffusion-weighted MRI in diagnostics
of renal disease, the lack of normalised data on water diffusion parameters in
kidneys impedes a comparison of results obtained in different centers. Our
study was aimed into establishing the normal ADC values in healthy kidneys,
comparing them with literature, and assessing the correlation between ADC
values, creatinine blood level, and GFR.
Methods
and Materials: 24 healthy volunteers and 26 living kidney donors
were examined on a 1.5 unit (Ingenia, Philips, The Netherlands). Two DWI
sequences were included in the study protocol (sequence I-16 b values,
sequence II- 10 b values). Before examinati on blood and urine samples were
collected. GFR was calculated with Cockcroft&Gault and MDRD (Modification
of Diet In Renal Disease) formulas and the ADC values were measured
separately for the cortex and medulla of each kidney by two independent
observers. All statistical analyses were performed using the STATISTICA
(version 10.0) software package. Data were analysed using an unpaired t test;
p-value< 0.05 indicated a statistically significant difference.
Results
The average ADC value for sequence I for the cortex was 2.26x10-
3 mm2/sec, for the medulla 2.21x10-3 mm2/sec. In protocol II, the respective
values were 2.13x10-3 mm2/sec and 2.06x10-3 mm2/sec. Neither statistically
significant interobserver differences nor correlation between ADC values, GFR,
and creatinine serum level were observed.
Conclusion
The average ADC values were established. The measurements
show high interobserver consistency. The differences in reported ADC values
suggest dependence on the equipment and methodology and point to the
necessity of obtaining ADC norms for each MR unit.
S319
BA C D E F G
Monday
B-0847 11:33
The role of MR perfusion in evaluating polycystic kidney disease:
correlation with laboratory data (creatinine clearance)
M.G. Bernieri, V. Panebianco, V. Forte, F. Barchetti, C. Zini, C. Catalano;
Rome/IT (
[email protected])
Purpose: To compare MRI perfusion technique with laboratory data (creatinine
clearance) in patients affected by polycystic kidney, in order to develop useful
MRI patterns to monitor the progression of the disease.
Methods
and Materials: 47 patients with polycystic kidney in various stages of
the disease underwent MRI examination with a 3 T magnet (GE Discovery MR
750) with multi-channel surface coil. For each patient first we evaluated the
morphological pattern by using T2 and T1 imaging, then we assessed the
vascularisation degree of the residual healthy renal parenchyma.
Vascularisation data were collected using a T1-weighted GRE perfusion
sequences acquired during intravenous administration of contrast medium
perfusion volume (PV). MRI patterns were correlated with laboratory data.
Results
A statistically significant correlation (P < 0.05) between PV of both
kidneys and creatinine clearance (CC) was found in all patients. A PV between
750 and 500 cm3 was correlated to a CC between 90 and 60 mL/min; a PV
between 500 and 200 cm3 corresponded to a CC between 60 and 30 mL/min
and a PV < of 200 cm3 corresponded to a CC < 30 mL7 min.
Conclusion
Functional MRI perfusion technique may be considered a
valuable tool for assessing the progression of polycystic kidney disease.
B-0848 11:42
Renal artery anomalies associated with horseshoe kidneys: value of CT
angiography
T. Ichikawa, J. Koizumi, S. Kawada, Y. Imai; Isehara/JP
(
[email protected])
Purpose: Arterial blood supply in patients with horseshoe kidney (HSK) is
abnormal in about 75% and troublesome on surgery such as aortic aneurysm.
We evaluated incidence of surplus renal arteries in HSK patients focused on
numbers and diameters using CT angiography (CTA).
Methods
and Materials: Thirty-two patients with HSK and 83 patients with
normal kidney (NK) underwent CT angiography (CTA) using 64 MDCT. Based
on 2D CT including MPR, MIP and volume-rendered images with 0.5 mm
reconstruction interval on CTA, we assessed incidence of surplus renal arteries
and those of greater than 3 mm in diameter and compared incidences of those
between HSK and NK patients using Chi-square test.
Results
Total 320 arteries were identified (HSK: 117, NK: 203). Mean
numbers of renal arteries were 3.66 ±1.1 in HSK patients and 2.45 ±0.7 in NK
patients. The incidence of patients with surplus renal arteries was 90.6% in
HSK patients and 33.7 % in NK patients. The incidence of patients with surplus
arteries greater than 3 mm in diameter was 68.7% in HSK patients and 8.4% in
NK patients. There was a significantly higher incidence of surplus renal arteries
and surplus arteries of greater than 3 mm in diameter in patients with HSK than
in NK patients on CTA (p=0.0029, 1.8E-6).
Conclusion
The incidences of large and surplus renal arteries were frequently
found in HSK patients. Evaluation of renal artery anomalies of HSK using CTA
may provide useful information for surgical managements and interventional
treatments.
B-0849 11:51
Dose-optimisation of dual-source, dual-energy CT for urinary calculi:
assessment of the image quality and radiation dose
M. Pansini
1, T. Schubert1, J. Hohmann1, B.K. Kovács1, Z. Szücs-Farkas2,
G.M. Bongartz1, S. Schindera1; 1Basle/CH, 2Biel/CH (
[email protected])
Purpose: To assess the image quality and radiation dose in dose-optimised,
dual-energy CT (DECT) for suspected renal stones.
Methods
and Materials: 75 patients who underwent unenhanced CT
(SOMATOM Definition Flash, Siemens) for urinary calculi were divided into
three groups of 25 patients each. In group A, DECT acquisition was performed
with the standard protocol (tube-A, 100 kVp, 210 reference mAs; tube-B,
140 kVp, 162 reference mAs); in group B a low-dose single-energy CT
(100 kVp, 100 reference mAs) was performed, followed, in case of stone-
depiction, by standard DECT acquisition targeted to the stones; group C
received a dose-optimised DECT protocol (tube-A, 100 kVp, 90 reference mAs;
tube-B, 140 kVp, 70 reference mAs), previously assessed in a phantom study.
The radiation dose was assessed with the dose-length product (DLP). The
image noise and the CNR were calculated. Subjective image quality was
analysed by three independent radiologists.
Results
Mean DLP in groups B and C (186.7 mGycm ±59.6 and
219.4 mGycm±57.3, respectively; P=0.39) were significantly lower compared
with group A (443.5 mGycm ±107.6) (P < 0.001). Image noise was similar in
groups B and C (8.9 HU ±2.6 and 9.5 HU ±3.2, respectively; P=0.65), but
significantly higher than in group A (5.9 HU ±1.7) (P < 0.001). The CNR was
significantly higher in group A (27.6 ±6.6) compared to groups B and C
(18.7±5.6 and 17.4± 5.3, respectively; P=0.7) (P < 0.001). In the subjective
analysis, the mean diagnostic image quality was rated as good or better for all
groups.
Conclusion
Compared to a low-dose, single-energy protocol, the radiation
dose of the standard DECT protocol, can be substantially lowered without
compromising objective and subjective image quality.
10:30 - 12:00 Room I/K
Neuro
SS 1711
Resting-state and task-based fMRI
Moderators:
M. Sasiadek; Wroclaw/PL
M. Vernooij; Rotterdam/NL
B-0850 10:30
Resting-state and stimulus induced fMRI data fusion
K.-H. Nenning, R. Donner, D. Prayer, G. Langs; Vienna/AT
(
[email protected])
Purpose: Contrary to stimulus induced fMRI, resting-state fMRI captures
spontaneous modulations in the blood oxygen level dependent signal during a
resting condition. Resting-state fMRI offers insight in the brains' intrinsic
connectivity architecture, and has clinical relevance. However, the relationship
to task dependent networks is not yet fully understood. In this work the joint
analysis of resting-state and stimulus induced fMRI data is evaluated.
Methods
and Materials: The dataset consisted of 22 subjects from the NKI-
RS - Multiband Imaging Test-Retest Pilot Dataset, published as part of the
1000 Functional Connectomes Project, with data acquisitions from a resting-
state condition and a visual checkerboard stimulus available for each subject.
Multiple Relational Embedding was used to establish a single joint embedding
space encoding the functional connectivity structures of the resting-state and
the visual checkerboard data. Functional registration followed by clustering
was used to delineate similar network structures across the group. Cluster
stabilities were quantified and compared to resting-state analysis without using
information about the visual stimulus and to concatenated time-series.
Results
The results show that the additi onal visual stimulus data causes a
stable split of the visual networks into two sub networks. Interestingly, the
additional visual stimulus causes also a more stable delineation of basic
resting-state networks, e.g. the default mode network. Additionally, it offers
higher cluster resolution, i.e. we can differentiate smaller clusters while the
cluster stability remains high.
Conclusion
The presented work shows that additional stimulus data can
facilitate resting-state analysis, it can increase the network resolution in
specific functional regions.
B-0851 10:39
Evaluation of multiparametric quantitative bold approach and
cerebrovascular reserve in patients with severe intracranial arterial
stenosis: a comparison study
J. Bouvier
1, O. Detante1, F. Tahon1, A. Attye1, T. Perret1, I. Tropres2, S. Grand1,
E. Barbier1, A. Krainik1; 1Grenoble/FR, 2Suresnes/FR
(
[email protected])
Purpose: To better characterise perfusion and oxygen metabolism disorders in
patients with severe intracranial arterial stenosis (SIAS), we studied basal and
functional changes of perfusion using functional MRI of cerebral vasoreactivity
(CVR fMRI) with oxygenation measurement using a multiparametric qBOLD
approach.
Methods
and Materials: Eleven patients (2 females; 65.6 ±15.2yo) with SIAS
of the internal carotid artery (n=5), middle cerebral artery (MCA) (n=6) were
studied. Basal perfusion was measured using dynamic susceptibility contrast
with deconvolution of the arterial input function to calculate conventional
parameters (CBF, CBV, MTT, Tmax). BOLD CVR fMRI was acquired with a
block-design hypercapnic challenge (8% CO
2). Average end-tidal CO2 pressure
(EtCO2) was used as a physiological regressor for statistical analyses (SPM8).
StO2 maps were obtained from a combination of CBV and T2' (1/T2'=1/T2*-
1/T2). Cerebral metabolic rate of oxygen (CMRO2) map was computed using
CMRO2=CBF.(1-StO2/100). Regions of interest (ROI) were drawn onto the
segmented gray matter of vascular territories of the MCA to record basal
perfusion CVR ( BOLD/mmHg EtCO
2) and CMRO2. For each parameter, we
calculated laterality indices with LIMCA=(LeftMCA-RightMCA)/(LeftMCA +
RightMCA).
Results
No adverse reaction to the protocol was reported. In the MCA territory
ipsilateral to SIAS, basal perfusion (CBF, Tmax), CVR, and CMRO2 were
impaired. Interhemispheric CMRO2 impairments expressed using LIMCA were S320
BA C D E F G
Monday
correlated with CBF (R=0.96, p < 0.001), MTT (R=-0.85, p < 0.001), and CVR
(R=0.92 p < 0.001).
Conclusion
In patients with SIAS, basal and functional hemodynamic
disorders are associated with a decreased oxygen metabolism, suggesting a
low-grade chronic ischemia.
B-0852 10:48
Effects of refractive errors on functional magnetic resonance imaging of
visual cortex
A. Akça, Y. Anık, Z. Sakçı, M. Gençtürk, B. Özkul, A. Kaya, Ö. Altınta;
Kocaeli/TR (
[email protected])
Purpose: The purpose of our study is to evaluate the effects of refractive
errors on functional magnetic resonance imaging of visual cortex
Methods
and Materials: We performed a prospective study that included 13
patients with refractive error (group 1) and 30 emetropic volunteers (group 2).
Group 2 was also subgrouped as 20-32 years old (young) and over 45 years
old (old) to analyse presbyopia and accomodation effect. fMRI data were
acquired with a block design pradigm with 3 Tesla MRI. In both groups, BOLD
data initially was acquired in normal refractive state. fMRI was performed again
in group 1 without their glasses/lenses and in group 2 with induced-myopia via
+2D and +4D lenses. BOLD activation areas on visual cortex were calculated
as square centimetre area in another workstation. Total activated area on
visual cortex was compared between normal refractive state and
induced/uncorrected refractive error.
Results
In group 1, fMRI data during uncorrected refractive error revealed
significantly decreased activation areas compared with corrected refractive
error (p=0.001). In group 2, induced-myopia resulted significant decrease
compared with normal refractive state. Decrease in activation areas was
significant both in 2D (p=0.003) and 4D (p < 0.001) myopia compared with
normal refractive state. Both in young and old group, activation areas were
significantly decreased during induced-myopia. We revealed no difference
between young and old groups.
Conclusion
fMRI is a useful method to facilitate function preserving surgery in
patients with brain tumour and epilepsy. Because the refractive errors affect
the visual fMRI activations, they should be corrected in all refractive states.
B-0853 10:57
Functional connectivity of the subthalamic nucleus changes with age
C. Mathys
1, F. Hoffstaedter1, J. Caspers1, S. Caspers2, S.B. Eickhoff1,
R. Langner1, C. Rubbert1; 1Düsseldorf/DE,
2Jülich/DE (
[email protected])
Purpose: The subthalamic nucleus (STN) plays a major role in motor control
(which is known to decline with age), but also in emotionally and cognitive
processing. The aim of this study was to detect age-related functional
connectivity (FC) changes of the STN with resting state imaging (RSI).
Methods
and Materials: 361 healthy adults (mean age 41.8 years) had RSI
scans (> 8.5 min) at three different sites. Th e bilateral STN seeds were derived
from 7-Tesla high-resolution susceptibility mapping. Confound removal
(motion; mean tissue class-related si gnals) and band-pass filtering (0.01-
0.08 Hz) was applied. Activity in the STN seed regions was represented by the
first eigenvariate of the respective voxels' time-series and then correlated with
the time-series of all other voxels in the brain. Age was used as a covariate in
the analysis to identify regions with age-related changes of FC (p < 0.05,
corrected for multiple comparisons at cluster level).
Results
An age-related decline of FC with STN was found for caudate
nucleus, thalamus (all right), for bilateral posterior insula and vermis, while a
decrease with age was found for bilateral sensorimotor cortex and bilateral
putamen.
Age-related decrease in functional anticorrelations with STN was detected for
left precuneus and left posterior cingulate cortex.
Conclusion
Changes in positive FC might provide a neural substrate for
degradation of motor performance. On the other side, the reduced uncoupling
of anticorrelated brain areas (like the precuneus, which is known to be involved
in introspection) might indicate an increased interference from irrelevant
cognitive processing in advanced age.
B-0854 11:06
Regional cerebral changes and functional connectivity during the
observation of negative emotional stimuli in earthquake survivors with
post-traumatic stress disorder in l'Aquila
M. Anselmi, A. Catalucci, V. Felli, L. Patriarca, M. Pino, M. Mazza, M. Gallucci;
L'Aquila/IT (
[email protected])
Purpose: Patients with PTSD exhibit exaggerated brain responses to
emotionally negative stimuli, which normally activate the limbic system.
Identifying the neural correlates of emotion regulation in these subjects is
important for elucidate the neural circuitr y involved in emotional dysfunction. To
investigate the functional connectivity between the areas activated during
emotional processing of negative stimuli in a sample of PTSD compared to
healthy subjects.
Methods
and Materials: Ten PTSD subjects (survived the 6.3magnitude
earthquake on April 6.2009 in L'Aquila) (DSM-IV-R, APA 2000) and ten healthy
controls underwent fMRI (GE 1.5 T), during observation of 80 images (40
negative emotional stimuli and 40 scrambled neutral stimuli). Clinical and
neuropsychological assessment was administered to all subjects with PTSD.
Statistical data analysis were performed using Brain Voyager QX4.6.
Results
A higher activation was found in the left posterior (LP) insula for
PTSD group, and in the ventromedial prefrontal cortex (vmPFC) for the healthy
group. Two sets of Granger causality modeling (GCM) analyses were
performed, to examine the directed influences to other brain regions from LP-
insula and vmPFC, identified individ ually for each PTSD and healthy subject
respectively. Activity in the vmPFC in the healthy group while observing
negative emotional stimuli predicted activi ty in several subcortical regions and
insula.
Conclusion
The activation of the fronto-limbic network in healthy but not in
PTSD suggests a lack of mediation and cortical control of emotional processes
in these patients. This pattern of directed influence can be interpreted as the
neural correlate of emotional control.
B-0855 11:15
Altered functional connectivity of the marginal division in medication
overuse headache using resting state fMRI
Z. Chen, X. Chen, L. Ma, S. Yu; Beijing/CN (
[email protected])
Purpose: To investigate the functional connectivity changes of the marginal
division (MrD) in the patients with medication overuse headache (MOH).
Methods
and Materials: Conventional MRI, 3D structure images and resting-
state functional MRI (rs-fMRI) were performed in 21 patients with MOH and 21
matched normal control subjects. MrD was defined using manual drawing on
structure images, and was applied to the computation of functional connectivity
(FC) maps. Two-samples t-tests were performed on the individual FC maps the
comparison of FC of MrD between two groups.
Results
Compared with normal controls, the increased functional connectivity
of left MrD was demonstrated in left inferior temporal gyrus, right anterior and
middle cingulate gyri for the patients with MOH. The increased right MrD
connectivity was gathered in the left inferior temporal gyrus and frontal orbital
gyrus, and right anterior cingulate gyrus. No decreased functional connectivity
was detected.
Conclusion
The results of increased functional connectivity of bilateral MrD
may support that MrD play a key role in the pathogenesis of MOH, and our
findings also suggest that the char acteristics of MrD connectivity could
plausibly provide an early imaging biomarker for the diagnositc and evaluation
of MOH.
B-0856 11:24
Effect of mindfulness meditation on BCI performance: a fMRI study
S.-S. Kuok, N. Ramli, Y.-Q. Tan, L.-K. Tan, L.-F. Tan, S.-Y. Goh, K.-J. Goh;
Kuala Lumpur/MY (
[email protected])
Purpose: To observe the functional changes in brain activity while performing
real and imagery movement using functional MRI (fMRI). To compare the fMRI
changes of motor imagery before and after mindfulness meditation (MM)
training and correlate this with actual brain computer interface (BCI)
performance.
Methods
and Materials: Eight right handed healthy volunteers were recruited
to participate the EEG brain mapping, BCI performance test and fMRI of real
and imagery movement of right hand (RH), left hand (LH) and both feet (BF).
They were then randomly assigned into control and intervention groups. The
intervention group received 12 hours of MM training. EEG brain mapping, BCI
performance test and fMRI scanning were repeated after intervention.
Statistical parametric mapping software was used for post processing and
analysis of fMRI data.
Results
fMRI groups results showed activation of motor imagery of RH, LH
and BF at premotor, prefrontal and vi sual cortices before MM training (p < 0.05,
FWE). After MM training, fMRI results revealed more focus of activation in 3
out of 4 of the trained subjects on RH motor imagery, 2 out of 4 of the trained
subjects on LH and BF motor imagery, comparing with the control group. This
is also correlated with the improvement of BCI accuracy of the intervention
group after MM training.
Conclusion
Mindfulness meditation improves BCI performance and is
associated with more focus of functional changes in cerebral cortex on motor
imagery.
S321
BA C D E F G
Monday
B-0857 11:33
Charting the emergence of the foetal functional brain connectome in the
thalamus and subplate: an in utero fMRI study
A. Jakab, G. Langs, E. Schwartz, G. Kasprian, D. Prayer, V. Schöpf;
Vienna/AT (
[email protected])
Purpose: Endeavours to optimise prenatal MRI have opened the way for the
utilisation of functional MRI in neurodevelopmental studies. We introduce an
image processing and evaluation approach for the exploration of recurrent,
developing patterns of fMRI signal fluctuations of the foetal brain.
Methods
and Materials: MRI was indicated to exclude or confirm
sonographically suspected abnormalities; after removing cases with motion-
related artefacts, images of 32 foetuses were analysed (gestational weeks: 21-
37). In utero functional brain MRI was performed using a gradient-recalled
echo-planar sequence on a 1.5 T scanner. Slices were acquired perpendicular
to the brainstem, each comprising 50 time points (TE/TR: 50/1000 ms).
Analysis included motion and nuisance signal correction approaches;
correlations of regional time courses were evaluated after transforming brains
to gestational week specific templates. ROIs of the thalamus and subplate
gross subdivisions were propagated through a temporal model of
morphological development and connectivity matrices were provided.
Results
Spectral coherence tests revealed sy nchronicity of fMRI time courses
within the subplate and thalamus in the 0.01-0.2 Hz frequency range. The
strength of thalamus-subplate interconnections remained strong in the
observed developmental phase (R > 0.5), whilst the regional subplate
connectivity showed increased inter-hemispheric correlations with a marked
shift from the 28
th week. We were unable to reveal long-range intra-
hemispheric connections in the mid- and late-foetal period.
Conclusion
In the mid-foetal period, brain activity can be characterised by
spontaneous, low-frequency signal fluctuations predominantly located within
the subplate. We suggest this in vivo technique for the refinement and
elucidation of models on the emerging human brain functioning.
B-0858 11:42
Alterations of the regional cerebral metabolism and dysfunction of the
resting state default mode network (RS DMN) in patients with Parkinson's
disease (PD) and different level of cognitive impairment (CI):
1H MRS and
fMRI study
Z.Z. Rozhkova, O.M. Omelchenko; Kiev/UA (
[email protected])
Purpose: To investigate local metabolic state and integrity of RS DMN
connectivity in patients with PD and different level of CI.
Methods
and Materials: Three groups of PD-patients (57-73y) with various
cognitive statuses are studied by fMRI, 1H MRS with 1.5 TSIGNAEXCITE (GE).
The 1st group (DPDG) consists of 13 PD-patients with dementia (MMSE MMSE25), 3 rd (NPDG)-12 PD-
patients with normal cognitive function (MMSE > 30). Spectra are recorded in
the white matter of the anterior (APCG), and in the posterior portion of
cingulate gyrus (PPCG): SVSSTEAM (TR/TE= 1500/144 ms). EPIBOLD scans
were acquired with: TR/TE=3000/71 ms. ICA analysis was used to identify 20
networks of RS-activity, MELODIC (FSL).
Results
In APCG, the values of NAA/Cr in DPDG, CIPDG, NPDG are:(1.68+-
0.02),(2.04+-0.03),(2.32+-0.05), Cho/Cr:(0.84+-0.02),(0.81+-0.05),(0.53+-0.03).
In PPCG values NAA/Cr in DPDG, CIPDG, NPDG are: (1.14+-0.12), (1.81+-
0.02), (1.98+-0.04), Cho/Cr: (0.96+-0.02), (0.77+-0.03), (0.68+-0.03). We have
found the progressive decreasing NAA/Cr in the PPCG and increasing of
Cho/Cr for the patient of NPDG, CIPDG, DPDG, associated with CI. The
analysis of the DMN revealed a gradual reduction in functional connectivity for
the patients of DPDG in the cuneus, precuneus and PPCG, which correlate
with severity of CI. Our findings suggest that RSNs involving areas of the
cerebellum and frontal lobe, that could be interpreted as a potential
compensatory mechanism to functional disorders caused by the CI. In NPDG
connections between APCG and PPCG, and infe rior parietal gyrus bilaterally
were found. In NPDG activation of APCG decreased, but connectivity patterns
persisted.
Conclusion
fMRI in RS, and MRS data gives as markers of neuronal
dysfunction in patients with PD and different level of CI.
B-0859 11:51
Eloquent brain areas localisation by functional MRI in tumour resection
surgery
A. Arellano Reynoso, E. Aguilar Castañeda; Mexico/MX
(
[email protected])
Purpose: To correlate the Neuronavigated Functional Magnetic Resonance
Imaging (fRMI) obtained with motor and language tasks with cortical
stimulation during tumour resection surgery.
Methods
and Materials: 48 patients with tumours in or around motor and
language areas were studied preoperatively with Functional 1.5 T Magnetic
Resonance Images (hand motor and language BOLD images). The images
were processed and integrated into a Brain Lab Vector Vision2
Neuronavigation System and compared during surgery with cortical and
subcortical stimulation. Motor and language tasks were the same at MR setting
and at the operating room. The differences were calculated and sensitivity and
specificity determined.
Results
A very good correlation was found in the hand motor area assessed
by fMRI when motor task was made actively by patient (sensitivity and
specificity of 96.8%). Language BOLD images has a low sensitivity and
specificity (37 and 66% respectively) and is not a reliable method to locate and
preserve language function during surgery. Patients who cannot execute motor
task actively were assisted and an activation area 9-13 mm caudal to motor
area confirmed by CS were found in all of them.
Conclusion
Although Cortical and Subcortical stimulation are the gold
standard in function location and preservation, progresses have been made in
development and performance in Image guided neurosurgery. A multimodal
imaging approach and its correlation with cortical and subcortical stimulation is
encouraged in order to progress in understanding in mechanisms of activation
and connectivity of eloquent brain areas.
10:30 - 12:00 Room L/M
Physics in Radiology
SS 1713
Novel MRI techniques
Moderators:
T.G. Maris; Iraklion/GR
W.J.M. van der Putten; Galway/IE
B-0860 10:30
Optimisation of k-space sampling and view-sharing parameters in time-
resolved MR angiography
K. Jaspers
1, W.H. Backes2, M.J.W. Greuter1, T.P. Willems1; 1Groningen/NL,
2Maastricht/NL (
[email protected])
Purpose: To optimise k-space sampling parameters in contrast-enhanced
time-resolved MR angiography with interleaved stochastic trajectories (TWIST-
MRA) for vessels with varying calibres.
Methods
and Materials: With TWIST-MRA, the centre of k-space (surface
area fraction fA) is acquired for every dynamic phase. An evenly distributed
fraction fB of the periphery is updated, supplementing the remainder with
previously or subsequently acquired data (forward and backward sharing,
respectively). TWIST acquisition was simulated in a 2D cross-sectional vessel
model (diameter=[3.5,10 pixels]). Dynamic signal profiles were constructed
from aortic enhancement curves measured with MRA. For scan time reduction
factors (RF=fA+fB*(1-fA)) of 20% and 35% of full k-space acquisition time, the
optimal combination of fA and fB in terms of maximal signal enhancement
(SEmax) and vessel blurring (VB, defined as average difference between
original and simulated image) was determined.
Results
Backward sharing produced higher SEmax and lower VB than
forward sharing. For RF=20%, SEmax was optimal for fA/fB=20/0%, resulting
in 84%, 93% and 96% of maximum input enhancement for diameter=3.5 and
10 pixels, respectively. For RF=35%, relative SEmax was 90%, 91%, and 95%
for diameter=3.5 and 10 pixels, respectively. VB was slightly higher for
RF=20% compared to RF=35%.
Conclusion
Optimal parameter selection depends on the area of interest. For
maximum enhancement of small vessels (diameter=3 pixels), backward view
sharing should be used and fA should be chosen as large as possible given a
certain RF. Reducing dynamic scan time by decreasing RF from 35% to 20%
only slightly decreased enhancement of small vessels, while low VB was
maintained.
B-0861 10:39
MRI-drawn pulsatile flow, can we accept it? In-vitro validation using
aortic flow model
J.J. Lee
1, J.-E. Park1, N. Lee1, J.-H. Kim1, S. Youn1, E.-J. Kang2; 1Daegu/KR,
2Busan/KR (
[email protected])
Purpose: MR phase-contrast imaging demonstrates pulsatile blood flow
velocity. The pulsatile flow pattern may show blood flow abnormality. The MR-
based pulsatile flow pattern was validated in vitro.
Methods
and Materials: An electromechanical pulsatile flow model was self-
established to simulate aortic blood flow. The model consisted of cylinder
pump, check valves, electromagnetic flowmeter, 19-mm silicone tube, 3
manometers, computerised controller, and ECG generator. As input variables,
heart rate (40-90 bpm) and systolic time interval ratio (30-60%) were
controlled. Stroke volume was fixed to 90 ml. The velocity data simultaneously
acquired by embedded electromagnetic flowmeter was used as the reference
standard. Under strictly controlled condition, MR phase-contrast imaging (3 T,
S322
BA C D E F G
Monday
40 phases, 100Cm/sec Venc) and particle-induced velocimetry (PIV, 15 Hz
repetition rate, 2Kx2K camera, Rhodamine-B fluorescent seeding particles)
were performed. By two-time data acquisition at each setting, 36 data sets
were acquired and compared.
Results
At whole 18 flow settings, the embedded flowmeter measured
maximal, minimal, and mean velocities as 84.02, 2.30, and 37.02 Cm/sec,
respectively. Whereas, MRI and PIV showed 76.15, 2.77, 35.83 Cm/sec and
48.02, 1.66, 21.73 Cm/sec, respectively. Maximal, minimal, and mean
velocities and time to half flow volume showed significant difference among 3
modalities (p < 0.001). However, the correlation with reference standard was
significant by MRI and PIV (p < 0.005). MRI showed significantly higher
correlation coefficient than PIV for maxi mal and mean velocities, and time to
half flow volume, except minimal velocity (p < 0.001).
Conclusion
Although MR-drawn pulsatile flow pattern showed blunted,
expanded, and delayed pulsatility, the correlation with standard reference was
acceptable.
B-0862 10:48
Automated selection of optimum acceleration parameters for highly
accelerated 3D contrast-enhanced MR angiography
S. Riederer, P.T. Weavers; Rochester, MN/US (
[email protected])
Purpose: To present the methodology and in vivo results which demonstrate
how optimum k-space sampling parameters can be selected for highly
accelerated (R8) 3D contrast-enhanced MRA.
Methods
and Materials: When acceleration is performed along the two phase
encode directions (Y, Z) of 3DFT acquisition, there is considerable flexibility in
selecting the individual accelerations R Y and R Z so that their product R Y x R Z
equals the target acceleration R. We show that the performance of a trial (R Y,
RZ) pair can be predicted by determining a metric which can be calculated from
the 3D coil sensitivity images. These images are themselves generally
acquired prior to the contrast-enhanced run of a CE-MRA exam. High-speed
computation enables the multitude (several hundred) of trial R-pairs to be
evaluated within seconds, allowing the optimum to be used in the actual
contrast-enhanced run. The method is tested in CE-MRA exams of the
abdomen, calves, and feet.
Results
For a given acceleration factor, e.g. R=8, the optimum R-pair
depends strongly on the anatomic region under study, the interplay of the coil
array with the body habitus of the individual patient, and the amount of air in
the FOV. It is shown that acceleration optimisation can provide marked
improvement in image quality compared to reference accelerations. Time-
resolved contrast-enhanced angiograms of the feet can be routinely generated
with sub-millimetre isotropic resolution and 6.5 sec frame times.
Conclusion
Automated selection of optimum parameters for 2D acceleration
in CE-MRA can be done on a patient-specific basis and permits high image
quality.
B-0863 10:57
Performance of fat-suppression in large field-of-view 3D T1w gradient
echo imaging of the body using a 3 T system with improved magnetic
field homogeneity
G. Sommer
1, T. Schubert1, T. Heye1, M.D. Nickel2, W. Horger2, B. Kiefer2,
E.M. Merkle1; 1Basle/CH, 2Erlangen/DE
Purpose: To compare the technical performance of spectral pre-saturation
(FatSat) and two-point Dixon fat-water separation (Dixon) for T1-weighted 3D
large FOV volume interpolated breath-hold examinations (VIBE) at 3 T.
Methods
and Materials: Ten healthy volunteers (7m, 3f, mean age 41 y,
range 26-71 y) were prospectively examined using a novel 3 T whole-body
MRI scanner (MAGNETOM Prisma, Siemens Healthcare) with excellent
magnetic field homogeneity (1.1 ppm at 50 cm diameter spherical volume). 3D
VIBE with FatSat and Dixon was applied with identical spatial parameters
(coronal FOV 450x363x192 mm
3, resolution (1.6 mm) 3). TR and TE were
minimised for each sequence (FatSat: TR=2.9 ms, TE=1.1 ms; Dixon:
TR=4.1 ms, TE=1.3/2.6 ms). Flip-angle was 10°. Acquisition time was 20s for
both methods with parallel imaging acceleration factors 3 using GRAPPA (with
FatSat) and 6 in two directions using CAIPIRINHA (with Dixon). Two
radiologists rated image quality on a 4-point scale (excellent-good-fair-poor)
and analysed the images for fat-suppression artefacts. Fat-suppression was
assessed quantitatively by contrast measurements of solid tissue (liver, psoas
muscle) compared to adjacent fatty tissue.
Results
Fat-suppression artifacts were significantly less with Dixon than with
FatSat (0.5 ±1.1 vs 6.1 ±2.1/dataset; P < 0.001). Dixon provided significantly
higher contrast than FatSat for liver (0.85 ±0.03 vs 0.78 ±0.06; P=0.003) and
muscle (0.85± 0.04 vs 0.77 ±0.08; P=0.02). Dixon was more often affected by
noise from parallel imaging than FatSat (6 vs 1 dataset). Overall image quality
of Dixon was rated (4 excellent, 4 good, 2 fair) vs. FatSat (8 good, 2 fair;
P=0.2).
Conclusion
Dixon provides significantly better quality of fat-suppression than
FatSat for large FOV body imaging at 3 T.
Author Disclosures:
M.D. Nickel: Employee; Siemens Healthcare. W. Horger: Employee; Siemens
Healthcare. B. Kiefer: Employee; Siemens Healthcare.
B-0864 11:06
MR thermometry feasibility during LITT in ex vivo porcine pancreas
F. Giurazza, G. Frauenfelder, R. Del Vescovo, E. Schena, P. Saccomandi,
G. Allegretti, F. Siano, B. Beomonte Zobel; Rome/IT
(
[email protected])
Purpose: Laser-induced thermotherapy (LITT) is a minimally invasive
treatment technique modality to treat neoplastic tissue. LITT effects are
influenced by parenchymal heat distribution and temperature monitoring is
critical for the procedural outcome. We evaluated effects of LITT on intensity
variation during porcine pancreases MR examination, in order to assess the
feasibility of MR thermometry during ablation procedure on pancreas.
Methods
and Materials: Two ex vivo porcine healthy pancreases undergoing
LITT (Nd:YAG laser, Power 2 W, Energy 480J) were monitored by a 1.5-T MR
scanner, utilising two fast Inversion-Recovery sequences (IRTF and SRTF).
Each pancreas was scanned during the whole treatment (session time 240s)
and images were analysed with MATLAB
®; signal intensity was recorded in two
Regions of Interest (ROIs): ROI-a and ROI-b, positioned at 7 and 20 mm from
the tip of laser applicator, respectively.
Results
In ROI-a, temperature increase caused a significant signal intensity
decrease in both sequences, while in ROI-b signal showed a negligible
variation due to the larger distance from the applicator. Evaluating ROI-a, IRTF
presented a higher thermal sensitivity than SRTF (i.e., -0.076s
-1 for IRTF and -
0.067s-1 for SRTF) in both pancreases. The result is confirmed by the
maximum decrease of the signal intensity during the procedure (-35 for IRTF
and -23 for SRTF). Signal decrease with SRTF sequence showed a significant
linear correlation with time (P < 0.01).
Conclusion
MR thermometry seems to be a valuable non-invasive and time-
effective approach to monitor thermal ablation effects on pancreas; in our
experience IRTF is more sensitive than SRTF.
B-0865 11:15
Evaluation of abdominal organs by using breath hold and non-breath
hold diffusion-weighted imaging
D. Herek, N. Karabulut, A. Kocyigit; Denizli/TR (
[email protected])
Purpose: Our aim was to evaluate the appa rent diffusion coefficient (ADC)
values of normal abdominal parenchymal organs and signal to noise ratio
(SNR) measurements in the same patients with breath hold (BH) and non-
breath hold (NBH) diffusion weighted imaging (DWI).
Methods
and Materials: Thirty-five healthy patients underwent both BH and
NBH DWI. Free hand region of interest (ROI) was placed on right hepatic lobe,
spleen, cortices of kidneys and pancreas. ADC values were calculated for
every organ on both BH and NBH sequences. Image noise was measured in a
ROI placed outside the abdomen. SNR was calculated using the formula: SNR
= signal intensity (SI)
(organ)/standard deviation (SD)(noise).
Results
There were no statistically significant differences in ADC values of the
parenchymal abdominal organs between BH and NBH DWI sequences (p
> 0.05). There were statistically significant differences between SNR values of
organs on BH and NBH DWIs. SNR of NBH DWI sequences were better than
BH sequences (p 65 years old (n= 9) and group 2 patients 65 years old (n= 26).
Statistically significant differences in SNR measurements of the kidneys
between group 1 and 2 were found on both BH and NBH DWI (p < 0.05). SNR
of kidneys decreases with age.
Conclusion
Non- breath hold (free breathing) DWI technique significantly
reduces image noise and increases SNR for abdominal examinations. We
recommend NBH technique for the evaluation of abdominal organs by DWI.
B-0866 11:24
Correlation between presurgical DTI-tractography motor tract definition
and intraoperative evoked potentials assessment
Y.P. Velasco Díaz
1, J. Sanchez Fernandez1, J. Quispe Bravo1,
G. Rivera Sierra1, P. Puyalto2, C. Aguilera1, M. Virumbrales Cancio3,
A. Olazabal2; 1Hospitalet de Llobregat/ES, 2Badalona/ES,
3Sant Cugat del Valles/ES (
[email protected])
Purpose: The objective of the study was to correlate the reliability of MR
tractography sequences to define the pyramidal tract and its translation into the
gross anatomy (obtained by evoked potentials)in order to conclude that MR
tractography assesses, before surgery, accurately the distance between the
pyramidal tract and tumour.
Methods
and Materials: 43 patients with gliomas near the pyramidal tract
were prospectively. Histological analysis confirmed: 13 diffuse anaplastic
gliomas, 4 oligoastrocytomas and 26 GBM. In the 43 patients the motor tract
was identified by presurgical MRI studies (DTI sequences and tractography)
S323
BA C D E F G
Monday
and MRI studies within 72 hours after surgery. The way of defining the
pyramidal tract was through the intersection of the fibbers passing through
three zones labelled in the precentral gyrus on the internal capsule and
ipsilateral cerebral peduncle. After craniotomy, the central sulcus was visually
identified and confirmed by evoked pote ntials. Direct cortical monopolar high
frequency phase (250 Hz) stimulation was performed. For cortical stimulation
an 8 contacts electrode was used whereas a current waveform with eight
electromyograms was used for evoked potentials continuous monitoring. When
resection approaches the pyramidal tract, subcortical stimulators were used
and the electromyographic response was observed after subcortical
stimulation.
Results
The distance between the resection cavity and the motor tract in
tractographic sequences postoperatively were 2.5 to 23.7 mm. The results
were correlated with data obtained from cortical evoked potentials monitored
during surgery. There was a significant linear correlation of 1.08 by applying a
regression test between distance and stimulus intensity (R2 = 0.8202,
P < 0.001).
Conclusion
Correlation was demonstrated between the electrophysiological
and DTI in the analysis of the pyramidal tract by imaging based on the use of
direct subcortical stimulation.The DTI sho uld be systematically included in the
standard imaging protocol for the study of brain tumours both for etiologic
diagnosis to treatment planning.
B-0867 11:33
The principles of diffusion-weighted magnetic resonance imaging (DWI-
MR): experimental models and clinical applications
F. Fornasa, L. Bernardin, F. Pantalone, M. Bellotti; S. Bonifacio/IT
(
[email protected])
Purpose: To clarify the origin of the findings obtained with Diffusion-Weighted
Magnetic Resonance Imaging (DWI) in its clinical (current and future)
applications.
Methods
and Materials: DWI measures the speed of the random movement
("diffusion") of extra-cellular water molecules, which varies among different
tissues according to several parameters such as the viscosity of the milieu, the
concentration of inorganic solutes and of macromolecules, the membrane
permeability, the number of cells and the temperature. In the diagnostic
workout of several diseases DWI is currently included (early recognition of
brain ischemia, differentiation between benign and malignant neoplasms,
monitoring of cancer outcome after therapy), while in some fields its possible
role is under investigation (characterisation of diffuse liver disease, evaluation
of pancreatic and intestinal inflamma tion, assessment of foetal organ
development, identification of physiologi c changes of the endometrium during
the menstrual cycle).
Results
The speed of diffusion decreases with increasing viscosity, increasing
concentration of inorganic solutes, increasing concentration of
macromolecules; it increases with cell membrane rupture and with the growing
number of cells, and directly parallels the changes in the temperature. These
relationships are confirmed by the measurement of diffusion in a series of
experimental models (raw versus boiled eggs and potatoes; distilled water
versus 5% sodium chloride water solution and emulsion of butter in water;
ripen versus rotten peaches; 25 °C versus 50 °C 5% sodium chloride water
solution and air-temperature versus frozen beefsteak).
Conclusion
Non-human experimental models help our comprehension of the
factors influencing the speed of water diffusion in human healthy and diseased
tissues.
B-0868 11:42
Side effects in ultra-high-field-MRI at 7 Tesla in comparison to a "Mock-
up"-scanner
B. Friebe
1, A. Wollrab1, M. Thormann1, M. Grüschow2, K. Fischbach1, J. Ricke1,
S. Kropf1, F. Fischbach1, O. Speck1; 1Magdeburg/DE, 2Zurich/CH
(
[email protected])
Purpose: To determine the subjective experience of subjects undergoing 7-
Tesla-MRI compared to a "Mock-up"-Scanner with no magnetic field.
Methods
and Materials: 44 healthy subjects were exposed both to the B0-
Field of a 7-Tesla-whole-body MRI and a realistic "mock-up" scanner with no
magnetic field. Subjects were blinded to the actual field strength and no
scanning was performed, i.e. no RF or gradient exposure. After exposure to
the B0-Field, subjects rated their experi ence regarding potential sensations of
discomfort, such as phosphenes, nausea, dizziness or vertigo.
Results
The most frequently observed side effect was vertigo while entering
the gantry, which was reported by 36.3 % (n= 16). Other frequent side effects
were the appearance of phosphenes (18.2%), unsteady gait after exposure
(13.6%), thermal heat sensation (13.6%) and dizziness (11.4%). Nausea
occurred in no case. All side effects were reported significantly more often after
7-Tesla exposure. However, regarding these five main side effects 19 subjects
(43.2 %) neither reported them in the 7-Tesla-Scanner nor in the mock-up
scanner.
Conclusion
Light vertigo while entering the gantry is the main side effect of
Ultrahigh-Field MRI consistent with previous reports. Other light subjective
sensations as the appearance of phosphenes, unsteady gait after exposure,
thermal heat sensation or dizziness can occur in a small percentage, of which
in part might not be correlated to the magnetic field exposure but to the subject
consent procedure, sensitizing them to possible effects. The appearance of
nausea in this study was well below that previously reported in the literature.
B-0869 11:51
MR safety: the potential of ferromagnetic detection systems and the
challenge of a ferrous-free policy
N. Oberhofer1, N. Surname2; 1Bolzano/IT, 2Merano/IT
(
[email protected])
Purpose: To evaluate advantages and limitations of ferromagnetic detection
systems in a ferrous-free MR environment.
Methods
and Materials: The commercial ferromagnetic detection systems
(Ferroguard®, Metrasens) consisted of a wall-mou nted, high sensitivity patient
screener (optical alarm) and a lower sensitivity doorway detector (optical and
acoustic alarm), mounted in front of the magnet room entry (in-swinging door,
1.5 T). For the latter, the detected signal (magnetic flux density variations) was
processed to activate the audible alarm only if appropriate. Besides a foldable
wheelchair and a patient bed (fixed height) were supplied, both MR conditional
3 T and not triggering any detector alarm. Additionally, site staff wore ferrous
free clothing. Patient screening was carried out on all walking patients after
changing clothes and the outcome registered.
Results
The "patient screener" was well accepted by staff and patients. 3
patients out of 399 were refused the scheduled exam because of
ferromagnetic items brought out by it. The door entry detector required
repeated fine tuning to adjust to site conditions and staff behaviour. In order to
avoid false alarms, staff needs to comply with minimal "behaviour rules".
Conclusion
Patient screener and doorway detectors are complementary. The
patient screener demonstrated simple in use, reliable in detecting hidden
ferrous items and helpful in avoiding potentially critical patient scanning.
Positioning the doorway detector a few meters ahead of the exam room entry
facilitates calibration and correct staff behaviour. To gain the most, the MR site
should embrace a "ferrous free" policy.
Author Disclosures:
N. Oberhofer: Equipment Support Recipient; Merano Hospital. N. Surname:
Equipment Support Recipient; Merano Hospital.
10:30 - 12:00 Room N/O
Emergency Radiology
SS 1717
New strategies in imaging
Moderators:
J.M. Artigas; Zaragoza/ES
C. Colantoni; Milan/IT
B-0870 10:30
Does inclusion of imaging in the work up of patients with clinically
suspected appendicitis reduce the rate of unnecessary surgical
procedures?
M.J. Lahaye, D.M. Lambregts, E. Mutsaers, B. Essers, S. Breukink,
R.G.H. Beets-Tan; Maastricht/NL (
[email protected])
Purpose: Since February 2010 new Dutch guidelines have been implemented
recommending the use of US or CT to confirm or refute clinically suspected
appendicitis before (laparoscopic) surgery. For equivocal cases with US
additional imaging (CT/MRI) is recommended. This study aimed to see whether
these new guidelines lowered the percentage appendix sana.
Methods
and Materials: This retrospective study included all consecutive
patients operated for clinically suspec ted appendicitis at our hospital from
2008-2009 (before guidelines) and 2011-2012 (after guidelines). The use of
imaging (none versus US, CT and/or MRI) and its findings were recorded.
Surgical and histopathological findings -where available- were notified. The
primary study endpoint was the number of appendix sana before and after the
guideline implementation.
Results
1556 patients were included, of which 756 were collected before the
implementation of the guidelines and 800 after. During the pre-implementation
period, 36.3% of the patients received imaging focussed on the appendix.
Post-implementation, 97.4% of the patients received imaging before surgery.
The average percentage of an 'appendix sana' before the guidelines was
23.2%. After implementation, this average percentage dropped significantly to
6.2% (p < 0.001).
Conclusion
Use of preoperative imaging in all patients with suspected
clinically appendicitis result in a si gnificant reduction in the percentage of
S324
BA C D E F G
Monday
'appendix sana'. This suggests that the implementation of imaging in the work
up of these patients could be an effective strategy to reduce the number of
unnecessary surgeries.
B-0871 10:39
Diagnostic imaging pathways and clinical outcomes of acute
appendicitis: a multi-institutional cross-sectional study
P. Ji Hoon1, LOCAT Group2; 1Seongnam-si/KR, 2Metropolitan Seoul/KR
(
[email protected])
Purpose: To investigate imaging utilisation patterns and the negative
appendectomy rate (NAR) in metropolitan Seoul.
Methods
and Materials: A cross-sectional study involving 2321 adolescents
and adults undergoing appendectomy in 2011 at eleven hospitals.
Results
Ten sites acquired multi-phase computed tomography (CT). The
typical effective radiation dose exceeded 10 mSv at 10 sites and 20 mSv at 2
sites. Overall imaging utilisation rate was 99.7% (95% confidence interval,
99.4%-99.9%). CT and ultrasonography utilisation rates as an initial imaging
modality were 93.1% (92.0%-94.1%), and 6.5% (5.6%-7.6%), respectively.
Relatively higher ultrasonography utilisation was associated with younger age,
female, and presentation during working hours. The overall NAR was 4.1%
(3.3%-4.9%). The NAR in patients undergoing CT only, complementary
ultrasonography following CT, ultrasonography only, and complementary CT
following ultrasonography were 3.3% (2.6%-4.1%), 27% (14%-44%), 9% (4%-
16%), and 8% (2%-20%), respectively. The use of ultrasonography instead of
CT as the initial imaging modality was significantly associated with the higher
NAR (adjusted odds ratio [AOR], 2.28 [1.22-4.27]; risk difference, 4.4 [0-8.8]
percentage points), however, the population attributable risk was 0.3 [0-0.6]
percentage points. The choice between CT and ultrasonography did not
significantly affect appendiceal perforation (AOR, 1.11 [0.74-1.66]).
Conclusion
We observed a very high CT utilisation rate and a low NAR in
metropolitan Seoul, similar to those recently reported from the United States.
The use of CT instead of ultrasonography as the initial imaging modality
significantly decreased NAR. However, only marginal further reduction of the
NAR would be achieved by additional utilisation of CT in the population.
B-0872 10:48
Signs of acute appendicitis on CT in comparison with both
histopathological findings and C-reactive protein
M. Karul, M. Avanesov, C. Behzadi, S. Keller, P. Stahl, G. Adam,
J. Yamamura; Hamburg/DE (
[email protected])
Purpose: To assess signs of acute appendicitis (AA) on multidetector
computed tomography (MDCT) and to compare findings with both
histopathological evaluation and C-reactive protein (CRP) levels.
Methods
and Materials: Preoperative MDCT images of 76 patients with
histopathologically confirmed AA were retrospectively interpreted by two
radiologists in consensus. Criteria for AA were appendiceal wall thickness
> 2 mm with ring-like contrast enhancement, increased cross-sectional
diameter > 6 mm, and periappendiceal fat attenuation. Abscess formation was
considered as a specific sign of appendiceal perforation. Patients were
categorised into one of three groups (GR) based on histopathological
classification: ulcero-phl egmonous (GR1), gangrenous (GR2), and perforation
with abscess formation (GR3). CRP levels were correlated using receiver
operating characteristic (ROC) curve analysis.
Results
49 patients were assigned to GR1, 5 to GR2, and 22 to GR3. AA was
diagnosed on MDCT in 42/49 cases (85.7%) in GR1, and 2/5 cases (40%) in
GR2. In the remaining patients MDCT was unremarkable, respectively.
Abscess formation with a diameter > 3 mm was diagnosed in 19/22 cases
(86.4%) in GR3. CRP levels were in normal range in 4/49 patients (8.2%) in
GR1, mildly elevated in all patients in GR2, and never < 59 mg/l in GR3. Mean
CRP levels significantly correlated with histopathological severity of
inflammation (p 72 mg/l.
Conclusion
MDCT is a powerful diagnostic tool to depict signs of AA and is
required immediately in patients with CRP levels > 72 mg/l to avoid
complications. CRP levels and signs of AA on MDCT taken together may
influence treatment strategy.
B-0873 10:57
Acoustic radiation force impulse elastography in diagnosis and staging
the severity of acute appendicitis
C. Göya, C. Hamidi, M. çer, A. Ouz, M.H. Okur, S. Hattapolu,
M.G. Çetinçakmak, M. Teke; Diyarbakir/TR (
[email protected])
Purpose: The aim of this study is to investigate the qualitative and quantitative
role of acoustic radiation force impulse (ARFI) elastography in the diagnosis of
acute appendicitis and also to compare it with histopathologic results along
with Alvarado score.
Methods
and Materials: Forty-eight follow-up patients with no apparent
complaint and 53 patients with right lower quadrant pain were evaluated using
ARFI elastography and ultrasonography (US). Following the recording process
for Alvarado scores, the severity of appendicular inflammation was assessed in
the 48 patients who were diagnosed with acute appendicitis on ARFI
elastography and later underwent surgery. Once the findings on imaging were
confirmed, the results were compared and al so the sensitivity and specificity
for Alvarado scores, ARFI elastography and US were then calculated.
Results
Alvarado score had a sensitivity of 79.59% and specificity of 93.51%,
ARFI elastography had sensitivity and specificity of 100% and 96.7% each,
whereas sonography had sensitivity of 91.03% and specificity of 96.70%.
According to the inflammation severity rates, 14 patients had mild, 12 had
moderate, and 22 had severe appendicitis.
Conclusion
The combined use of US and ARFI elastography raises both
qualitative and quantitative sensitivities in the diagnosis of acute appendicitis
and can also be used in severe and pervasive inflammation.
B-0874 11:06
Usefulness of contrast-enhanced ultrasound in the diagnosis of acute
gangrenous cholecystitis: a comparative study with surgical and
pathological findings
I. Carbonell, R.R. Revert, M. Martínez, Y. Fernández, J. Vizuete, T. Ripolles;
Valencia/ES (
[email protected])
Purpose: Determine usefulness of contrast-enhanced ultrasound (CEUS) for
the diagnostic of acute gangrenous cholecystitis (AGC), compared with
pathologic specimens as gold standard.
Methods
and Materials: From December 2011 to March 2013, patients with
clinical and sonographic diagnosis of acute cholecystitis underwent a CEUS
examination. CEUS diagnosis of AGC was made when discontinuity of
gallbladder wall enhancement was seen after contrast injection. Sonographic
findings prospectively evaluated were: wall thickness, biliary sludge, lithiasis,
Murphy sign, wall striations, intraluminal membranes, wall interruption,
pericholecystic fluid, or hyperemia. We included only patients who underwent
cholecystectomies 24 hours after CEUS. Sonographic was compared with
pathologic analysis of the gallbladder speci men. Sensitivity, specificity, positive
and negative predictive values, and CEUS accuracy were calculated.
Retrospectively, two experienced radi ologists reviewed sequences to calculate
interobserver agreement, using kappa statistics.
Results
64 patients were included (32 women, mean age of 71 years). Final
pathological diagnoses were 6 chronic cholec ystitis, 10 acute cholecystitis and
48 AGC. Absence of gallbladder wall enhancement on preoperative CEUS
image was accurately associated with pathologically confirmed AGC
(sensitivity, specificity and accuracy of 79.2%, 81.3% and 79.7%).
Interobserver agreement was good (k value: 0.719). Radiologic criteria with
highest sensitivity and specificity to gangrenous form were defects of
enhancement, wall striations and biliary sludge. Intraluminal membranes had
high specificity (92.8%) but low sensitivity (22.9%).
Conclusion
Local or widespread absence of gallbladder wall enhancement
on CEUS is associated with the presence of AGC.
B-0875 11:15
Diagnostic accuracy of full-body linear X-ray scanning in trauma patients
in comparison to CT
A. Jöres, J.T. Heverhagen, A. Exadaktylos, T. Klink; Berne/CH
(
[email protected])
Purpose: To evaluate the diagnostic accuracy of full-body linear X-ray
scanning (LS) in polytrauma patients in comparison to computed tomography.
Methods
and Materials: Following institutional review board approval, 106
polytrauma patients (female, 33; male 73; mean age, 46.7 years; age range,
16 - 93) were retrospectively included in this study. All patients underwent
linear slot X-ray scanning (LS; Lodox Statscan, South Africa) of the whole-body
including extremities (scan time,13s/1.80m; entrance dose, 0.12 mGy), and
128-multi-slice computed tomography (MSCT; Definition Edge, Siemens,
Forchheim, Germany) covering neck, thorax, abdomen, and pelvis during
2012. Diagnostic accuracy of LS for the detection of fractures of the truncal
skeleton and pneumothoraces was evaluated in comparison to MSCT by two
observers in consensus. Extremity fractures detected by LS were documented.
Results
Overall sensitivity of LS was 50 .0%, specificity 93.3%, positive
predictive value 91.2%, and negative predictive value 57.5% in comparison to
CT. Sensitivity for vertebral fracture s was 16.7%, and specificity 100%.
Sensitivity was 50.0% and specifici ty 98.2% for all other fractures.
Pneumothoraces were detected in 13 patients by CT, but not by LS. 30
fractures of the extremities were detected by LS, but not covered by MSCT.
Conclusion
Diagnostic accuracy of LS is limited in the evaluation of acute
trauma of the truncal skeleton. LS allows for fast and ultra-low dose whole-
body X-ray imaging, and may be valuable for detecting extremity fractures in
trauma patients additional to CT imaging.
S325
BA C D E F G
Monday
B-0876 11:24
Bowel and mesenteric injuries in blunt abdominal trauma: the role of
multidetector-CT for addressing a surgical approach
M. Tonerini; Pisa/IT (
[email protected])
Purpose: To describe the MDCT findings of blunt bowel and mesenteric
injuries (BBMI) and to determine which types of lesions warrant a surgical
approach.
Methods
and Materials: Retrospective study of 30 patients (18 male; 12
female; mean age 35 y.o). who sustained a major trauma and who were
evaluated with a 64- MDCT in a I level Emergency Department. The MDCT
findings were evaluated by an experienced staff dedicated for Emergency
Radiology (24 h) and they were then confirmed by laparotomy/laparoscopy or
by MDCT follow-up.
Results
70% patients had surgically important BBMI and 30% of patients had
surgically unimportant BBMI. Bowel wall defect, bowel wall ischemia,
extraluminal air, mesenteric vessel beading or extravasation and abrupt
termination of mesenteric vessels showed the best positive likelihood for
surgically important BBMI. Mesenteric infiltration, intraperitoneal fluid, bowel
wall thickening or bowel wall abnormal enhancement were not specific findings
of BBMI and they did not warrant an emergent surgical approach. The absence
of peritoneal fluid showed the best negative predictive value.
Conclusion
MDCT accurately revealed surgically important BBMI. When
nonspecific features of BBMI are the only CT findings, the need for surgical
intervention is highly dependent on clinical judgment. Reevaluation with MDCT
within 6-8 hours may help to elucidate the significance of such findings.
B-0877 11:33
Follow-up and characterisation of indeterminate spleen lesions in
primary CT after blunt abdominal trauma: potential of MR imaging
S. Gordic, H.-P. Simmen, G. Wanner, D. Cadosch, H. Alkadhi; Zurich/CH
(
[email protected])
Purpose: To determine the value of MR imaging for follow-up and
characterisation of indeterminate spleen lesions in primary CT of patients with
blunt abdominal trauma.
Methods
and Materials: Twenty-five patients (8 female, mean age 51.6 ±22.4
years) with an indeterminate spleen lesion diagnosed at CT after blunt
abdominal trauma underwent MR imaging with T2- and T1-weighted images
pre- and post-contrast material administration. MR images were reviewed by
two radiologists. Age, gender, injury mechanism, injury severity score (ISS),
management of patients, time interval between CT and MR imaging, and
length of hospital stay were included into the analysis. Patient history, clinical
history, imaging and two-month clinical outcome including review of medical
records and telephone interviews served as reference standard.
Results
From the 25 indeterminate spleen lesions in CT, 11 (44%) were
traumatic and 14 (56%) non-traumatic. The ISS (P
.05). The MR imaging features ill-defined lesion borders, variable
signal on T1-and T2-weighted images, focal contrast enhancement indicating
traumatic pseudoaneurysm, perilesional contrast enhancement and edema
were indicative for traumatic spleen lesi ons. As compared to CT (2/25), MR
images (5/25) better depicted thin subcapsular hematomas as indicator of
traumatic spleen injury.
Conclusion
MR imaging shows value for follow-up and characterisation of
indeterminate spleen lesions in primary CT after blunt abdominal trauma and is
helpful for discriminating traumatic from non-traumatic spleen lesions.
B-0878 11:42
X-ray findings and morphologic changes in lungs after thermal injury
E.A. Beresneva, S.V. Smirnov, S.V. Sheviakova, T.G. Spiridonova,
M.V. Barinova; Moscow/RU (
[email protected])
Purpose: To characterise changes in lungs after thermal injury.
Methods
and Materials: We have studied chest X-ray findings and lung
morphology changes following thermal injury in 240 patients distributed in 3
groups: isolated inhalation injury (Group 1), skin burn only (Group 2), the
combination of inhalation injury with a skin burn (Group 3).
Results
Following inhalation injury, lung edema and pneumonia were most
commonly revealed by X-ray at early stage (day 1-2, and day 3-4,
respectively). We identified a radiographic sign indicating a terminal bronchiole
obstruction, and appearing in X-ray as peripherally located (in the lung) small
clear bubbles closely arranged in a "mulberry" pattern. Terminal bronchiole
obstruction was confirmed morphologically. In 45.1% of Group 2 patients no
abnormalities in lungs were seen. Pneumonia was the most common
complication occurring at week 2-3. In combination of inhalation injury and skin
burn, chest X-ray showed no abnormal signs in lungs in 35% of patients in
initial 5-6 days. Only some patients showed the radiologic sign of "mulberries"
or signs of venous congestion. Advanced pulmonary edema and pneumonia
were reveled later: at day 7 or 8. Morphology demonstrated increased blood
volume in all vessels, sludge, and blood clots.
Conclusion
We found radiologic and morphologic differences between the
three groups. The radiologic sign of "mulberries" is consistent with the terminal
bronchiole damage and lumen obstruction. Absence of abnormal X-ray signs in
lungs of patients with combination of inhalation injury and skin burn in initial
several days suggests the presence of severe microcirculation impairments.
B-0879 11:51
The lung CT patterns in fat embolism syndrome
M. Piolanti, M. Fiscaletti, C. Coniglio, G. Dalpiaz, M. Miceli, S. Violini,
L. Barozzi; Bologna/IT (
[email protected])
Purpose: The aim of this study is to define the lung CT pattern of the
pulmonary involvement in fat embolism syndrome (FES).
Methods
and Materials: In this study, 3 radiologists retrospectively reviewed
18 CT studies of patients with clinical diagnosis of pulmonary fat embolism
syndrome. The protocol was approved by the Ethics Committee of the AUSL of
Bologna, Italy. Imaging evaluation was particularly focused on the lobular
abnormalities, and the terminology use d followed the Fleischner Society
glossary of 2008. Presence and extension of all CT signs of interstitial and
alveolar involvement were carefully assessed by consensus by the observers.
Statistical analysis was performed to analyse distribution of the findings and
correlate them with the clinical parameters.
Results
All patients in our series showed presence of nodules and micro-
nodules with random distribution. Consolidations and ground-glass opacities
were present in all patients as well. Consolidations had predominantly a
dependent distribution, while ground glass opacities had always a random
distribution. Ground glass opacities and nodules resulted to be prevalent in the
upper lobes while consolidation prevailed in the lower lobes.
Conclusion
In conclusion, from the CT findings of our series FES seems to
have a peculiar CT pattern; although it is not a specific CT pattern in itself, in
the proper clinical context CT findings might well suggest, or confirm, the
diagnosis of pulmonary FES.
10:30 - 12:00 Conf. Room M3
Interventional Radiology
SS 1709
Percutaneous ablation
Moderators:
C.W. Kim; Busan/KR
G. Widmann; Innsbruck/AT
B-0880 10:30
Systemic hyperthermia after local tumour ablation: comparison of
monopolar and multipolar radiofrequency ablation
A.H. Mahnken
1, V. Fischer1, J. Tacke2, P. Bruners3; 1Marburg/DE, 2Passau/DE,
3Aachen/DE (
[email protected])
Purpose: To assess changes in body temperature during mono- and
multipolar radiofrequency (RF) ablation.
Methods
and Materials: 112 consecutive patients (62 male; 63.8 ±12 years)
undergoing RF ablation for primary or secondary hepatic malignancies were
included in this retrospective analysis. All monopolar ablation procedures
(n=164) were performed with the RF3000 system (Boston Scientific, Natick,
MA) with LeVeen probes (2-4 cm), while multipolar ablation procedures (n=69)
were performed using the Celon Power generator (Celon, Teltow, G) with 1 to
6 RF-probes. Body temperature was continuously monitored throughout all
procedures via an oral temperature probe (Datex-Ohmeda, GE-Healthcare,
Chalfont St. Giles, UK). Data were statist ically analysed using Wilcoxon test
and uni- and multivariate analysis of variance.
Results
Both ablation techniques resulted in a significant increase in body
temperature (p < 0.0001) with an average increase of body temperature of
1.4±1.6 (0-5.9)°C in monopolar and 0.7 ±0.7 (-0.1-2.2)°C in multipolar ablation.
The increase in body temperature was significantly lower with multipolar
ablation (p < 0.0001), when compared with monopolar ablation. Multivariate
analysis proved probe size (p < 0.0001), ablation duration (p=0.0002) and
summarised tumour diameter (p=0.049) to have a significant influence on
changes in body temperature. Proximity to large vessels did not show
significant effects on body temperature (p > 0.05).
Conclusion
The use of multipolar ablation is an effective option to minimise
systematic body heating in RF-ablation of liver tumours. In high-risk patients,
this offers a strategy to avoid negative side effects of systemic body
hyperthermia, as it may occur in monopolar RF-ablation of large lesions.
S326
BA C D E F G
Monday
B-0881 10:39
Efficay and cost-analysis of radiofrequency ablation compared to surgery
for the treatment of benign thyroid nodules
G. Bazzocchi, S. Bernardi, C. Dobrinja, B. Fabris, N. Sabato, V. Ulcigrai,
E. Barro, N. De Manzini, F. Stacul; Trieste/IT (
[email protected])
Purpose: The aim of this study was to evaluate radiofrequency thermal
ablation (RFA) efficacy, tolerability and costs, and comparing it to
emithyroidectomy, including short stay thyroid surgery, for the treatment of
benign thyroid nodules.
Methods
and Materials: 29 patients underwent RFA of benign thyroid nodules
and were compared with 72 patients surgically treated, either in a standard
inpatient or in a short stay surgical regimen. Efficacy, complications, cosmetic
score and costs were evaluated.
Results
RFA reduced nodular volume by 68% after 6 months and it was
effective in treating all nodule-related clinical problems, including
hyperthyroidism, neck symptoms and cosmetic score. RFA and surgery,
regardless of the length of the hospital stay, were both safe, although RFA had
less complications. RFA, however, did not allow for any pathological analysis
of the nodules, which, in 5 patients who underwent surgery (7%), revealed that
the nodules harboured malignant cells. RFA costs 1629 €, surgery costs 4668
€ and short stay surgery costs 4218 € per patient.
Conclusion
These data suggest that RFA cost-effectiveness is likely to
transform our approach to benign thyroid nodules.
B-0882 10:48
CT-guided RF ablation improves survival in patients with liver metastases
from breast cancer
A.H. Mahnken1, K. Kühl1, P. Bruners2; 1Marburg/DE,
2Aachen/DE (
[email protected])
Purpose: To evaluate the results of radiofrequency (RF) ablation in the
treatment of liver metastases from breast cancer.
Methods
and Materials: 29 female patients (age 49 ±12 years) with 76 liver
metastases from breast cancer were included in this retrospective analysis. All
patients had previously received chemotherapy. Mean lesion size was
2.4±1.3 cm. Extrahepatic metastases were present in 18/29 patients with bone
(15/29) and lung (9/29) metastases being the most common locations of
extrahepatic disease. CT-guided RF-ablation of liver metastases was
performed using 2-4 cm LeVeen probes. Follow-up included contrast enhanced
CT every 3-6 months. Mean follow-up period was 18 (1-75) months. Overall
survival and factors affecting outcome were analysed using Kaplan-Meier
statistics and univariate analysis of variance.
Results
A total of 47 treatment sessions were successfully completed without
major complications. Minor complications were observed in 4/29 patients, with
one patient requiring embolisation for bleeding. Complete necrosis was
achieved in all lesions. Local recurrence rate was 6.5%. Median survival from
ablation was 27 months. Corresponding 1- and 3-year overall survival rates
were 81% and 33%, respectively. Univariate anaylsis did not show a significant
effect of extrahepatic disease, number of metastases or diameters of lesions
on survival. There was a trend towards a better survival if RF-ablation was
performed within 3 months after the diagnosis of liver metastases (p=0.0669).
Conclusion
Percutaneous RF-ablation has a role in the management of
metastatic breast cancer. Extrahepatic disease should not preclude treatment if
the liver is the dominant site of metastatic disease.
B-0883 10:57
Patient outcome after pulmonary radiofrequency ablation: a prospective
analysis of results from a single centre
C.J. Zagorski, S.A. Forbes, P.E. Jennings, R. Soomal, S.L. Smith; Ipswich/UK
(
[email protected])
Purpose: To assess the safety of pulmonary RFA and analyse factors
affecting overall survival and disease fr ee survival in patients with pulmonary
malignancy treated with ablation.
Methods
and Materials: 90 tumours in 45 patients treated between April 2009
and August 2013 during 83 separate procedures were analysed using a
prospective database. For each patien t we recorded the histologically
confirmed nature of the primary tumour, site and number of metastases and if
the patient received prior chemotherapy or other treatments. On a lesion-by-
lesion basis we recorded the lesions' site and size, ablation details, lesional
progression free survival, complications and overall survival. Factors were
compared using log rank testing and Kaplan-Meier survival analysis performed.
Results
Median overall survival was 105 weeks from initial RFA, with 1, 2 and
3-year survival of 95.5%, 89.9% and 77.7% respectively. 15 lesions (17%)
developed recurrence; with mean time to recurrence 32 weeks. 40% of those
with recurrence occurred when the lesion abutted a major vessel. Repeat RFA
in 8 of these 15 lesions demonstrated no further recurrence in 7. The rate of
significant complications (those requiring treatment) was 12%. Patients with 3
lesions ablated had a mean survival of 150 weeks, compared to 195 weeks in
those with a total number of lesions 2. This came close to statistical
significance (p=0.091).
Conclusion
Three-year survival of 77.7% compares favourably with surgery.
Patients with 3 lesions treated are likely to have lower survival than those
with 2 lesions treated.
B-0884 11:06
Diaphragmatic hernias after lung percutaneous radiofrequency ablation:
incidence and risk factors
N. Alberti1, G.R. Ferretti2, X. Buy1, J. Palussiere1; 1Bordeaux/FR, 2Grenoble/FR
(
[email protected])
Purpose: To evaluate diaphragmatic hernias (DH) after PRFA for basal lung
nodules and detect risk factors.
Methods
and Materials: Between January 2009 and December 2012,
presence of DH was retrospectively recorded in all the patients who underwent
percutaneous radiofrequency ablation (PRFA) with multitine expandable
electrodes for ablation of lower-lobe nodule. All the nodules were classified into
three groups according to the location of the tines after deployment relative to
the diaphragm. In group 1, the tines were at a distance of more than 1 cm to
the diaphragm. In group 2, at least one tine was in contact with the diaphragm
without perforation. Finally, in group 3, at least one tine was perforating the
diaphragm.
Results
Four cases of DH (3 on the left side, 1 on the right) were recorded in
our series of 156 patients (2.3% of our procedures). The delay of onset was
7.8 months. Only the three DH that occurred on the left side were symptomatic
(2 intussusceptions and one gastroesophageal reflux) and were surgically
repaired. DH occurred in groups 2 (n=1) and 3 (n=3). The electrode was
positioned in the centre of the diaphragm in all cases.
Conclusion
The central position of the electrode and the contact of at least
one tine with the diaphragm after deployment seem to be a risk factor to
develop a DH.
B-0885 11:15
Ablation therapy of hepatocellular carcinoma (HCC): a comparative study
between radiofrequency ablation (RFA) and microwave ablation (MWA)
T.J. Vogl, S. Zangos, J. Trojan, N.N.N. Naguib, N.-E. Nour Eldin;
Frankfurt a. Main/DE (
[email protected])
Purpose: To prospectively evaluate and compare the therapeutic response of
radiofrequency ablation (RFA) and microwave ablation (MWA) of
hepatocellular carcinoma (HCC).
Methods
and Materials: This prospective study was approved by the
Institutional review board and written informed consent was obtained from all
patients. From September 2008 to December 2011, 53 consecutive patients
(42 males/11 females; mean 59 years; range 40-68) underwent CT-guided
percutaneous RFA and MWA of 68 HCC-lesions. Inclusion and exclusion
criteria were in accordance with the Barcelona Clinic Liver Cancer (BCLC)
criteria. Morphologic tumour response (number/location/size) was evaluated by
MRI. Follow-up protocol was 24 h post ablation, 3-month intervals post ablation
in the first year and 6-month intervals thereafter.
Results
Complete response was documented in 84.4% (27/32) of lesions
treated with RFA and in 88.9% (32/36) of lesions with MWA (p=0.6). Complete
response was achieved in all lesions 2.0 cm in diameter in both groups. There
was no significant difference in rates of residual foci of HCC-lesions between
RFA and MWA (p=0.15, Log-rank test). Recurrence rates for 3, 6, and 9
months were 6.3%, 3.1%, 3.1% in RFA vs. 0%, 5.6%, 2.8% in MWA. Time-to-
progression in patients treated with RFA was 6.6 months vs. MWA 8.3 months.
Progression-free-survival was 96.9%, 93.8% and 90.6% (RFA group) at 1, 2,
and 3 years and 97.2%, 94.5%, and 91.7% (MWA group), respectively
(p=0.98).
Conclusion
In conclusion, RFA and MWA showed no significant difference in
the treatment of HCC regarding complete response, rates of residual foci of
untreated disease and recurrence rate.
B-0886 11:24
Microwave ablation (MWA) therapy of liver metastases from colorectal
carcinoma post-systemic chemotherapy
N.-E.A.N. Mohammed, N.N.N. Naguib, T. Lehnert, T.J. Vogl;
Frankfurt a. Main/DE (
[email protected])
Purpose: To evaluate the safety, efficiency, effectiveness, and overall
outcome in patients treated with microwave thermal ablation of colorectal
metastases post-systemic chemotherapy.
Methods
and Materials: An institutional review board-approval was obtained
with informed consent of all patients. Retrospective analysis of prospective
intention to treat study was performed from January 2008 to January 2013, and
included 92 patients (mean age 56 years SD: 2.6) with 132 liver metastases
measuring 0.7-5.0 cm, who were treated with microwave ablation (MWA).
Local tumour control, complications, and long-term survival were analysed.
S327
BA C D E F G
Monday
Results
The mean follow-up period was 32.5 months. Complete ablation was
achieved in 117 of 132 (88.6%) nodules. Seventeen of the 117 (14.5%)
successfully treated nodules developed local recurrence. Univariate analysis
showed that tumour size of < 3 cm is a significant risk factor (P = 0.04).
Multivariate analysis showed that number of cycles of chemotherapy
(FOLFOX) was a significant prognostic factor for overall recurrence (P=0.03),
whereas disease-free interval was the si gnificant prognostic factor for distant
recurrence (P=0.03). Major complications occurred in 1.1% of patients. No
procedure-related mortalities were observed. The 1-, 2-, 3-, and 5-year overall
survival rates after the initial ablation were 82, 61.2, 51.2, and 38.3%,
respectively. The main cause of death was systemic tumour progression in
65.3% of the patients.
Conclusion
MWA is a safe and effective treatment therapeutic option for
patients with liver metastases from colorectal carcinoma post-systemic
chemotherapy.
B-0887 11:33
MRI chest parameters used in the assessment of tumour response post-
microwave ablation of pulmonary metastases
N.-E.A.N. Mohammed, N.N.N. Naguib, A. Emam, S. Zngos, T. Lehnert,
T.J. Vogl; Frankfurt a. Main/DE (
[email protected])
Purpose: To determine the value of contrast enhanced MRI (CE-MRI)
follow-up in the assessment of tumour response of microwave (MW) ablated
pulmonary metastases by correlating the results with CE-CT.
Methods
and Materials: This prospective study included 130 ablation
sessions for pulmonary metastases in 80 patients. CE-MRI chest scanning was
performed 1 week before the ablation and at 24 hours, 3, 6, 9 and 12 months
post-ablation. Thin-section CT volumetric measurement of the lesions was
performed at the same time periods as a second parameter for comparison.
The lesion MRI enhancement intensity in each study was estimated, and the
ratio to the paraspinal muscle enhancement intensity at the same level was
measured (Lesion muscle signal (LMS ratio). The correlations between post-
ablation follow-up CT volume of tumours and CE-MRI LMS ratio at the
follow-up periods were assessed.
Results
The preablation tumour volumes were in the range of 0.30-6.1 cm
(mean: 1.5 cm³, SD: 1.3). LMS ratio 1 was noted in: preablation due to high
contrast enhancement of the tumour,in 24 h post-ablation due to the
inflammatory response associated with the thermal ablation and due to tumour
residue or progress. Weak correlation was detected between the LMS ratios
and CT volumetric changes in 24 h post-ablation. Strong correlation between
the LMS ratios was estimated between the follow-up periods of 3 months
(Spearman R: 0.62, p=0.0021), 6 months (Spearman R: 0.66,p=0.001),
9months (Spearman R: 0.61, p < 0.001) and 12 months (Spearman R:0.7,
p < 0.00001).
Conclusion
CE-MRI follow-up of the MW ablated lung tumours can be used
effectively to assess the tumour response to ablation using LMS ratio as a
parameter of assessment.
B-0888 11:42
Mid-term outcome of percutaneous image-guided cryoablation on
inoperable extra-abdominal desmoid tumors
M. Havez, F. Cornelis, N. Lippa, S. Al Ammari, M. Kind; Bordeaux/FR
(
[email protected])
Purpose: To report the effectiveness and mid-term outcome of percutaneous
image-guided cryoablation on extra-abdominal desmoid tumors.
Methods
and Materials: The institutional review board approved this study
and informed consent was waived. Between 2011 and 2012, 13 patients (17
tumors), with a mean age of 39.3 years (15-74), consecutively treated with
cryoablation under ultrasound (n=8), computed tomography (n=1) or both (n=8)
guidance for extra-abdominal desmoid tumors were retrospectively selected
and followed until 2013. The study included 2 patients with Gardner syndrome
and 9 recurrences on ablative site after initial surgical treatment. Tumor
volumes were between 0.8 to 127.2 mm3 (median: 28 mm3). Disease free
survival (DFS) and local control were calculated on clinical (pain evaluation)
and imaging (according to RECIST criteria) follow-up, respectively. Kaplan-
Meier method was used for calculation of DFS.
Results
Cryoablation was performed under general (n=15) or local (n=2)
anesthesia. Two probes were used in mean (range: 1-4) per procedure. Mean
follow-up was 10.3 months (4-27 months). The disease-free survival rates
based on clinical evaluation were 82.3% at 6, 12 and 24 months. The rates of
local tumour progression based on RECIST criteria were 0% at 6, 12 or 24
months. Eight patients (47%) presented asymptomatic residual tumors
surrounding the ablative site on imagi ng follow-up. Two patients (12%)
presented an in situ recurrence. The major complications rate was 5.8% per
session (1/17).
Conclusion
Despite high rate of partial ablation, percutaneous image-guided
cryoablation appears to be safe and effective for mid-term local control in case
of inoperable extra-abdominal desmoid tumors.
B-0889 11:51
Percutaneous cryoablation of lung tumours: one year follow-up
C. Pusceddu; Cagliari/IT (
[email protected])
Purpose: To report the data of one year follow-up with CT-guided
percutaneous cryoablation (PCA) in patients with primary and secondary
pulmonary tumours.
Methods
and Materials: CT-guided PCA was performed on 46 lung masses
(18 NSCLC = 39%; 28 metastases = 61%) in 40 consecutive patients not
suitable for surgical resection. Lung ma sses were treated using three types of
cryoprobes: IceRod, IceSfere and IceSeed capable of obtaining different size
of iceball. After insertion of the cryoprobes into the lesion, the PCA were
performed.
Results
All cryoablation sessions were successfully completed. All tumours
were ablated. No procedure-related deaths occurred. Morbidity consisted of
20% (8 of 40) pneumothorax, 7% (3 of 40) pleural effusion and 3% (1 of 40)
cases asymptomatic small pulmonary haemorrhage, respectively, all of CTCAE
grade 1 (Common Terminology Criteria for Adverse Events). Low density of
entire lesion, central necrosis and solid ma ss appearance were identified in 32
(70%), 8 (17%) and 6 (13%) of cryoablated tumours, respectively. Technical
success was achieved in 80%, 95%, 91% and 85% of treated lesions at 1-, 3-,
6-, and 12-months CT follow-up scan, respectively. Comparing the tumour
longest diameter between the baseline and at 6 and 12 months CT images,
technical success was revealed in 91% and 83% cases, respectively.
Conclusion
Cryoablation of the lung tumours is a safe and effective
procedure capable of obtaining complete ablation of the tumour in a high
number of patients after one year follow-up.
10:30 - 12:00 Board Room A
Radiographers
SS 1714
Exploring current issues in medical
imaging practice
Moderators:
V. Donoghue; Dublin/IE
N.N.
B-0890 10:30
Best single-slice CT location to measure visceral adipose tissue in
children
M. O'Connor, J. Ryan, S. Foley; Dublin/IE (
[email protected])
Purpose: To investigate the optimal single CT slice location for predicting total
abdominal visceral adipose tissue (VAT) volume in children and the relations
between anthropometric measurements, gender, age and VAT volume.
Methods
and Materials: With ethical permission, 112 abdomen CT scans
were retrieved from the PACS systems of paediatric hospitals in Ireland (N= 3),
via a random stratified sampling, according to age and gender. VAT area was
measured at each intervertebral level between T12 and S1 using Image J
analysis software by setting threshold values of -190 to -30 HU and manually
segmenting VAT. Abdominal VAT volume was then derived. Waist
circumference (WC) and sagittal diameter (SD) were measured at L3-L4 and
L4-L5 slices, respectively. Single-slice VAT measurements were correlated
with total VAT volume for each slice to identify the optimal slice location for
VAT measurements. Regression analysis was used to evaluate WC, SD, age
and gender as VAT volume predictors.
Results
Preliminary results have shown that VAT area measured at L4-L5
(r=0.919) was best correlated to abdominal VAT volume in males and at L2-L3
in females (r=0.951). Mean abdominal VAT volume was lower in males
(2,443.7 cm^3) than in females (3,490.5 cm^3) although this was not significant
(p=0.237). Regression between WC, SD, age, gender and VAT volume
showed that waist circumference was most predictive of VAT volume
(Beta=1.076, p=0.001).
Conclusion
The optimal slice location for VAT measurements was at L4-L5 in
male children and L2-L3 in female children.
S328
BA C D E F G
Monday
B-0891 10:39
Risk factors leading to coronary heart disease within the Maltese
population: further factors for consideration
K. Borg Grima1, L.A. Rainford2, P. Bezzina1, D. O' Leary2; 1Msida/MT,
2Dublin/IE (
[email protected])
Purpose: Several cardiovascular risk factors are identified within the literature:
age, smoking history, blood pressure and c holesterol levels are the major risk
factors leading to coronary heart disease (CHD) (Desai et al, 2004). Many
researchers have indicated that these traditional risk factors alone fail to
explain the high mortality and morbidity rates associated with CHD, suggesting
that underlying risk factors may also be present. This work investigates the risk
factors leading to CHD within the Maltese population, as part of an ongoing
PhD study.
Methods
and Materials: Ethical approval was obtained to review 250 patient
medical histories for cardiovascular risk factors within the Maltese population.
Primary risk factors were established from a CHD literature search, however
risk criteria that are not always taken into consideration such as chronic kidney
disease, diabetes and the presence of in flammatory arthritic conditions were
also included. The electrocardiogram and myocardial perfusion scintigraphy
Results
in comparison to the results of the Duke risk score were also
considered.
Results
The results obtained were compared through regression analysis and
the use of IBM SPSS (version 20). Risk factors unique to the Maltese
population such as employment type and body mass index were also included.
The results were discussed in semi-structured interviews with the Nuclear
Medicine physicians and Cardiologists working in Malta to establish a triage
system uniquely fitted to these patients.
Conclusion
The triage of patients into appropriate cardiac scintigraphy
protocols cannot be exclusively based upon the traditional CHD risk factors
established within the literature.
B-0892 10:48
Sex estimation from scapular length measurements by CT scan images in
a Caucasian population
F. Giurazza
1, R. Del Vescovo1, E. Schena1, F. Paternostro2, B.B. Zobel1,
G. Frauenfelder1; 1Rome/IT, 2Florence/IT (
[email protected])
Purpose: Together with race, stature and age, sex is a main component of the
biological identity. Thanks to its proportional correlation with parts of the human
body, sex can be evaluated form the skeleton. The most accurate approach to
determine sex by bone size is based on os coxae or skull. After natural
disaster or in archaeological findings, t heir presence can never be guaranteed.
Herein, sexual dimorphism in the human scapula is used to develop a two-
variable discriminant function for sex estimation.
Methods
and Materials: We have enrolled 100 males and 100 females with a
mean age of 64.2 years (SD 12.8 years) who underwent low-dose thoracic CT
scan evaluation and we have estimated two scapular diameters: longitudinal
scapular length (LSL) and transverse scapular length (TSL). The estimation
has been carried out by analyzing images of the scapulae of each patient after
three-dimensional post-processing reconstructions.
Results
The two-variable function allows to obtain an overall accuracy of 88%
on the calibration sample; using a single scapular parameter accuracy was
84% for LSL and 87% for TSL. Furthermore, we have employed the mentioned
function on a collection of 10 Caucasian adult skeletons and sex has been
correctly predicted in 9 cases.
Conclusion
In our study, scapula seemed to be a valuable skeletal segment
for sex estimation: the two-variable discriminant function provide accuracy of
88% and 90% for the calibration sample and the skeletons, respectively.
B-0893 10:57
Clinical audit in a service of paediatric radiology: preliminary approach
R.M. Grunho, F.S. Pires, J. Santos, G. Paulo; Coimbra/PT
(
[email protected])
Purpose: Radiation protection and dose optimisation play key roles in pediatric
radiology mainly due to children's high sensitivity to radiation. Clinical audit is a
process that aims to improve the quality of healthcare, being essential in a
Paediatric Radiology department. The main objective was perform the first step
of Clinical Audit in a Radiology Department, evaluating the radiological practice
in pediatrics and establishing local Diagnostic Reference Levels (DRL's),
allowing analyse a potential optimisation.
Methods
and Materials: After selecting the two most common radiological
procedures by radiological modality, we performed a retrospective data
collection in PACS with 10 patients by procedure and specific age (0, 5, 10 and
15) in order to establish local DRL's based on the 75
th percentile of the dose
descriptors.
Results
The local DRL's were: 6 mGy.cm2, 38 mGy.cm2, 7 mGy.cm2 and
11 mGy.cm2 for chest radiography (0, 5, 10 and 15 years respectively);
38 mGy.cm2 and 314 mGy.cm2 for pelvis radiography (5 and 10 years);
48 mGy, 50 mGy, 55 mGy and 63 mGy for head Computed Tomography (CT),
(0, 5, 10 and 15 years, respectively); 2 mGy 4 mGy for and chest CT (5 and 15
years respectively), and 104 mGy.cm2 for micturating cystourethrography in
newborns.
Conclusion
The local DRL's obtained for the chest and pelvis radiography
and micturating cystourethrography are in accordance with the ones
established in the European level. The majority of the local DRL's in CT are
above the levels specified in comparat ive studies, which indicates a large
margin of optimisation of these procedures.
B-0894 11:06
Acoustic noise in MRI
Ó. Tavares1, H. Simões1, J. Castro Costa2, E. Cantante1, M. Santos1;
1Coimbra/PT, 2Castelo Branco/PT (
[email protected])
Purpose: Hearing loss, caused by noise, is one of the 10 most common
diseases in the European Union. The acoustic noise in magnetic resonance
(MR) is associated with activation and deactivation of the electrical current that
induces vibrations in the gradient co ils. The noise levels of the safety
guidelines of the Food and Drug Administration (FDA) according to
measurements should be between 65 and 95 dB. Determine radiographer
noise daily personal exposure at work per day (LEX, 8h) and the sound
pressure level peak (LCpico). With this values, potential harm from exposure to
noise in MR cloud be analysed and prevent and control noise
recommendations will be created.
Methods
and Materials: The study was divided into three phases: a screening
test of acoustic noise with a sonometer, measurements with a dosimeter
DC112 in radiographer shoulder during several sequences and measurements
during one day daily practice of radiographer.
Results
The daily personal noise exposure at work per day was 75.8 dB (A)
and the sound pressure level was 88.4 dB (C). The obtained frequency values
are according to FDA Guidelines.
Conclusion
We conclude that the sequences noisiest are the diffusion and
the quieter the SPGR. In none of the evaluations to check noise levels higher
than those imposed by the Directive No 2003/10/EC of the European
Parliament and of the Council of 6 February and Portuguese law 182/2006.
B-0895 11:15
A study of the psychological distress of fMRI volunteers
C. Vandulek1, G. Biro1, L. Refi2, L. Toth1, M. Emri3, I. Repa1, A. Kovacs1;
1Kaposvár/HU, 2Budapest/HU, 3Debrecen/HU (
[email protected])
Purpose: The majority of MRI patients have experienced some form of
distress; distress may compromise the outcome of the examination. Due to the
limited data available of the measure of distress amongst fMRI subjects, this
study aimed to study the anxiety level of fMRI volunteers.
Methods
and Materials: Eighteen volunteers participated in the study. The
State-Trait Anxiety Inventory (STAI) was used for data collection. The test was
taken pre and post in every fMRI examination to map the volunteers' level of
anxiety. The STAI test was supplemented with the measurement of the
volunteers' blood pressure and pulse rate pre and post fMRI examinations.
Results
The results of the STAI test revealed the volunteers' tendency for
anxiety in general, as well as a measurable state of current anxiety pre and
post the fMRI examination. The results of the STAI test pre and post fMRI
examination revealed that the subjects' state anxiety level decreased following
the fMRI examination in comparison with their level prior to the examination
(p=0.032. The results of the volunteers' blood pressure showed no significance
between the values pre and post examination (p=0.65). Decrease of the
volunteers' pulse rate following the examination was significant (p=0.005).
Conclusion
This study aimed to measure the level of anxiety pre and post
fMRI data acquisition since it may influence the outcome of an fMRI
examination. The results of the STAI test did not confirm distress amongst the
volunteers. This may be attributed to the careful patient preparation prior to the
examination.
B-0896 11:24
A European collaborative research study investigating paediatric cardiac
interventional radiation dose levels
D. Catania
1, M. Pasquato1, L. Masterson2, S. Foley2, L.A. Rainford2; 1Milan/IT,
2Dublin/IE (
[email protected])
Purpose: To investigate examination protocols and radiation dose levels
during paediatric cardiac interventional procedures in two European centres.
Methods
and Materials: Institutional permission was granted to access
imaging records. Retrospective data (n=12 months) was collated in the Irish
national centre for paediatric cardiac imaging, performed on a Siemens Bicor
unit. Examination data was age categorised: 0 > 1 years, 1 > 5 years, 5> 10
years, 10> 15 years, 15> 18 years, and 18+ years. Italian prospective data was
collated for five matching cardiac in terventional examinations performed using
Philips Integris Allura equipment: aortic coarctations; aortic and pulmonary
S329
BA C D E F G
Monday
valvuloplasty procedures, ICD and pulmonary PTA studies. Equipment and
protocol details were recorded to include: detector specifications, X-ray beam
filtration levels and type, magnification factors applied and routine frame rates
during fluoroscopy and image capture.
Results
Irish data for 405 procedures resulted and Italian data for specified
procedures is on-going. Comparable additional copper filtration levels of
0.2 mmCu were identified and similar screening rates of 25 fps and
magnification factors routinely applie d. Preliminary findings indicate Italian
examination times are within ranges recorded in the Irish centre, across the
five age groupings. DAP levels are comparable, however the 10-15 age
grouping recorded higher DAP readings for the bi-plane imaging equipment
(Irish centre) compared to the flat panel detector model (Italian centre). Across
both centres procedural imaging times generally decreased with increasing
patient age.
Conclusion
Initial findings indicate com parable practice and dose outcomes
across European paediatric cardiac centres. Further review of imaging
protocols and the completed dose data analysis will be presented.
B-0897 11:33
The influence of observer training for the detection of simulated
pulmonary lesions on single CT images of an anthropomorphic chest
phantom: a jackknife alternative free-response ROC analysis
C. Buissink
1, J. Thompson2, M. Voet1, A. Sanderund3, L.V. Kamping1,
L. Savary4, M. Mughal3, C.S.P. Rocha5, G.E. Hart2, R. Parreiral5, G. Martin6,
P. Hogg6; 1Groningen/NL, 2Manchester/UK, 3Oslo/NO, 4Lausanne/CH,
5Lisbon/PT, 6Salford/UK (
[email protected])
Purpose: To determine the influence of both observer training in free-response
methodology and simulated lesion appearances on an observer's ability to
successfully localise simulated lesions within an anthropomorphic chest
phantom on single computed tomography (CT) images.
Methods
and Materials: 34 undergraduate radiography students, attending an
ERASMUS intensive programme, analysed 46 (31 abnormal containing 1-3
lesions, 15 normal) low-resolution CT images produced primarily for
attenuation correction (AC) by two single photon emission computed
tomography/computed tomography (SPECT/CT) systems. The evaluation was
completed under two conditions, pre- and post-training, with a six-week wash-
out period between evaluations. Lesions were localised under the free-
response receiver operating characteristic (FROC) paradigm and each
evaluation was analysed separately using jackknife alternative FROC
(JAFROC) analysis.
Results
JAFROC analysis revealed a stati stically significant difference in
lesion detection performance between the two sets of low-resolution CT
images in both evaluations (pre-training, F (1,506) = 25.2, p < 0.001; post-
training, F (1.1435) = 32.6, p < 0.001). In addition to offering a slight increase in
statistical power, the figure-of-merit ( 4) for all treatments was increased from
the pre-training evaluation (0.684 (0.573.0.796) and 0.437 (0.334.0.540)) to the
post training evaluation (0.784 (0.694.0.875) and 0.560 (0.464.0.655)). The
incorrect localisation fraction was also reduced post-training (0.128) compared
to pre-training (0.282).
Conclusion
Focussed training of lesion appearances and FROC
methodology has a significant impact on a naïve observer's ability to localise
simulated lesions on CT images produced with an anthropomorphic chest
phantom.
B-0898 11:42
Task shifting towards radiologists in medical imaging: what are the views
of the radiographers?
H.H. Hjemly, E. Stranden, A.M. Myklebust; Drammen/NO
(
[email protected])
Purpose: To explore and provide insight about radiographer's opinions in
general, and identify influential fa ctors, regarding task shifting towards
radiologists and to provide knowledge for further research and work with
radiographer's role development in to advanced practice.
Methods
and Materials: Qualitative methods based on focus group
discussions with 11 radiographers from a medium to large-sized hospital in the
health region southeast of Norway. An inductive data analysis was done with a
hermeneutic approach in five stages. Results are seen in relation to previous
research and the researcher's own experience related to task shifting for
radiographers in Norway.
Results
The radiographers in the study express that the most limiting factor
for task shift into advanced practice is resistance amongst the radiologists. The
radiographers believe that by relieving some advanced diagnostic
responsibilities from the radiologists, they can lead to service improvements.
However, in spite the negative a ttitude amongst radiologists towards
radiographers taking on diagnostic responsibilities, and the lack of formal
support from the department, the radiographers do take decisions regarding
justification and clinical follow-up when they feel they have to so in the best
interest for their patients.
Conclusion
The radiographers in the study are motivated for task shift
towards radiologists, but experience strong resistance in terms of negative
attitudes. The study provides knowledge that may be of value in future
research and planning of role development processes for radiographers and
teamwork in clinical imaging. The study also indicates need for investigation of
scope and effect of informal advanced radiographer practice.
B-0899 11:51
Molecular MRI
N.F. Kezi; Margate/UK (
[email protected])
Purpose: To introduce the new, innovative and cutting-edge MR technique
named molecular-MRI.
Methods
and Materials: The molecular-MRI as a high-sensitivity MR
technique provides vital information at the cel lular or nanomolar level. mMRI is
used both for medical diagnostics and for research purposes. Ideal for therapy
planning and monitoring/follow-up. Can give precise information about the
gene expression and facilitates the examination of cell migration. Very efficient
at characterising angiogenesis and brain tumours/its expression levels
(VEGFR-2). A recent study evaluates the mMRI differentiation of VEGFR-2
levels in untreated gliomas in a GL261 mouse model. The expression of
VEGFR-2 levels was evaluated by using anti-VEGFR2-albumin-Gd-DTPA
probe with mMRI. Two separate treatment groups show us different uptake of
these levels in tumour region.
Results
Focusing on the study, it confirmed that in vivo VEGFR-2 levels can
be monitored as function of therapeutic evaluation. Optimisation is always the
key priority.
Conclusion
mMRI offering all these advantages, can help the scientific
community to evaluate better the architecture of the 'nano-world' and definitely
will be a powerful tool in molecular imaging.
10:30 - 12:00 Room P
Contrast Media
SS 1706
New applications and developments
Moderators:
N. Lassau; Villeiuif/FR
A. Wibmer; Vienna/AT
B-0900 10:30
Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA
enhanced MRI: should we use single-dose, double dose or half-dose?
S. Kinner, V. Steinweg, A. Radtke, M. Forsting, T. Schröder;
Essen/DE (
[email protected])
Purpose: Detailed knowledge of the biliary anatomy is essential to avoid
complications in living donor liver transplantation. The aim of this study was to
determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced
magnetic resonance cholangiography (ce-MRC) with reference to contrast-
enhanced CT cholangiography (ce-CTC).
Methods
and Materials: 30 potential living liver donors underwent both ce-
CTC and ce-MRC. Ce-CTC was performed after drip infusion of meglumine
iotroxate. For ce-MRC, ten candidates each received single, double or half-
dose Gd-EOB-DTPA. Ce-MRC images with and without inversion recovery
pulses (T1w ±IR) were acquired 20-30 minutes after intravenous contrast
injection. Image data were quantitatively and qualitatively reviewed by two
radiologists based on a on a 5-point scale. Data sets were compared using
Mann-Whitney-U-test or Wilcoxon-rank-sum-test. Kappa values were also
calculated.
Results
All image series provided sufficien t diagnostic information both
showing normal biliary anatomy and variant bile ducts. Ce-CTC showed
statistically significant better results compared to all ce-MRC data sets
(p < 0.001). T1w ce-MRC with single dose Gd-EOB-DTPA proved to be
superior to half and double dose in subj ective and objective evaluation without
a statistically significant difference (p=033-0.62). Interobserver agreement was
good to excellent (k=0.69-0.9).
Conclusion
T1w MRCP after Gd-EOB-DTPA is at any dosage still inferior to
meglumine iotroxate-enhanced CTC. Si nce preoperative planning of bile duct
surgery most often is focused on the central biliary anatomy, T1w ce-MRC
meets these specific diagnostic demands and allows for replacing harmful ce-
CTC strategies. Best results were seen with single dose GD-EOB-DTPA
combined with an inversion recovery sequence 20-30 minutes after injection.
S330
BA C D E F G
Monday
B-0901 10:39
Enhancement properties of a high relaxivity macromolecular Gd-based
contrast agent (P846) with a standard extracellular Gd-chelat (Gd-DTPA)
in rats with experimental liver tumours at 9.4 Tesla
P. Fries
1, D. Morr1, A. Müller1, P. Robert2, R. Dabew1, A. Massmann1,
R. Seidel1, A. Buecker1, G.K. Schneider1; 1Homburg/DE, 2Roissy/FR
(
[email protected])
Purpose: To evaluate the enhancement properties of an experimental Gd-
based, high relaxivity, macromolecular contrast agent (P846, Guerbet
Research, Aulnay-Sous-Bois, France) in comparison with a standard
extracellular Gd-chelate (Gd-DTPA) at 9.4T in a rat model of hepatic colorectal
cancer metastases.
Methods
and Materials: Nine rats with hepatic metastases were evaluated on
a 9.4T MRI unit (Bruker, Germany) acquiring T1w self-gated FLASH
sequences (TR/TE=45/2.5 ms, FA=45°, TA=1:23 min, FOV=5.12x5.12 cm2,
matrix=256x256) before and at 10 consecutive time points after contrast
injection. Each animal received intraind ividually both agents at equal doses of
0.1 mmol/kg body weight separated by 48 h. Based on ROI measurements we
calculated SNR of normal liver tissue (SNRliver) and tumors (SNRtumor), CNR
and lesion enhancement (LE). Statistical analyses included paired t-tests and
Wilcoxon tests (p < 0.05).
Results
Mean SNRliver, SNRtumor, CNR and LE were significantly higher
using P846 as compared with Gd-DTPA (mean ( ±SD), p < 0.001 each):
SNRliver: Gd-DTPA 17.3 ( ±1.2)/P846 24.6 ( ±1.5), SNRtumor: Gd-DTPA
23.8 (±1.8)/P846 37.2 ( ±2.0), CNR: Gd-DTPA 6.5 ( ±0.9)/P846 12.6 ( ±0.9) and
LE: Gd-DTPA 7.9 ( ±1.8)/P846 13.9 ( ±2.0) were significantly higher for P846 as
compared to Gd-DTPA. Both compounds demonstrated comparable
enhancement kinetics with an early peak followed by a gradual washout.
Conclusion
P846 provides significantly better enhancement at 9.4T as
compared to Gd-DTPA for equal doses of injected Gd. The large molecular
size and subsequent reduced rotational rate of P846 improves the interaction
with protons leading to a higher relaxivity. Yet, P846 demonstrates contrast
kinetics comparable to those of the extracellular agent during the first 20 min
after application in this liver metastases model.
Author Disclosures:
P. Robert: Employee; Guerbet. A. Buecker: Research/Grant Support; BMBF
(German Ministry of Education and Research, Grant Number: 0314101).
B-0902 10:48
Intraindividual comparison of an experimental high relaxivity extracellular
Gd-based contrast agent (P03277) with Gadubutrol in a rat model of
hepatic metastases at 9.4 Tesla
P. Fries
1, A. Müller1, P. Robert2, J. Stroeder1, M. Menger1, A. Massmann1,
R. Seidel1, G.K. Schneider1, A. Buecker1; 1Homburg/DE, 2Roissy/FR
(
[email protected])
Purpose: To evaluate the enhancement properties of the experimental
extracellular Gd-based contrast agent P03277 (Guerbet Research, Aulnay-
sous-Bois, France) compared with the commercially available extracellular
contrast agent Gadobutrol (Bayer HealthCare, Berlin, Germany) in a model of
hepatic colon cancer metastases in rats at 9.4T.
Methods
and Materials: 10 rats with hepatic metastases were examined by
MRI using a 9.4T animal scanner (Bruker, Germany). Each animal received an
intravenous injection of 0.1 mmol/kg body weight (BW) Gadobutrol. Two days
later, P03277 was applied at 0.1 mmol/kg BW. T1w self-gated FLASH
sequences (TR/TE=45/2.5 ms, alpha= 45°, TA=1:23 min, FOV=5.12x5.12 cm2,
matrix:256x256) were acquired before and at 10 time points after contrast
injection. SNR of tumor (SNRtumor) and liver tissue (SNRliver), contrast-to-
noise ratio (CNR) and lesion enhancement (LE) were calculated based on ROI
measurements. Statistical analyses included paired t-test and Wilcoxon tests
(p < 0.05).
Results
Mean SNRliver, SNRtumor, CNR and LE were significantly higher
using P03277 as compared with Gadobutrol at equal doses (mean ±SD):
SNRliver: Gadobutrol:16.3 ±4.5 / P03277:21.6± 6.1 (p= 0.027). SNRtumor:
Gadobutrol:21.8±4.8 / P03277:31.8± 6.2 (p=0.003). CNR: Gadobutrol:5.0 ±2.5 /
P03277:9.3±3.3 (p=0.002). LE: Gadobutrol:8.4± 5.5 / P03277:16.4 ±5.3
(p=0.02). Both agents demonstrated an early peak enhancement followed by a
continuous washout during the experimental period (20 min).
Conclusion
P03277 demonstrates better contrast enhancement properties as
compared to Gadobutrol applied at equal doses (0.1 mmol/kg BW) in this
model of hepatic metastases. Based on its high relaxivity P03277 is a highly
effective compound for contrast enhanced studies in animal tumor models at
9.4T.
Author Disclosures:
P. Robert: Employee; Guerbet.
B-0903 10:57
Diagnostic imaging after Yttrium 90 therapy in patients with
hepatocellular carcinoma (HCC): preliminary comparison of magnetic
resonance imaging with Gd-EOB-DTPA and gadobutrol
S. Kinner, J. Ertle, J.M. Theysohn, G. Gerken, N. Sippel, M. Forsting,
T.C. Lauenstein; Essen/DE (
[email protected])
Purpose: A precise evaluation of tumour response after Yttrium-90 (Y90)
therapy is essential for adequate clinical management. However, evaluation of
imaging may be hampered as Y90 itself can lead to reactive liver changes with
similar appearance to progress. We compared liver MRI using a liver specific
contrast agent (Gd-EOB-DTPA) gadobutrol-enhanced liver MRI concerning
therapy response evaluation.
Methods
and Materials: 20 patients with HCC underwent contrast-enhanced
computed tomography (CT) and gadobutrol MRI on the day before and Gd-
EOB-DTPA MRI directly before Y90 therapy. Follow-up images were
performed 30, 90 and 180 days after therapy. Two radiologists reviewed the
gadobutrol and Gd-EOB-DTPA enhanced liver MR images in consensus. They
rated therapy response using a 4-point-scale: 1=definitely response,
2=probably response, 3=probably no response, 4=definitely no response. CT in
combination with laboratory parameters served as reference standard.
Results
CT and laboratory parameters revealed progress in 5 patients after
30, 3 patients after 90 and 7 patients after 180 days. With Gd-EOB-DTPA MRI
radiologists were more determinate compared to gadobutrol-MRI (mean values
day 30 for responders with Gd-EOB-DTPA=1.4; gadobutrol=1.9). In one patient
each on day 90 and 180 radiologists rated gadobutrol-MRI as probable
response while Gd-EOB-DTPA MRI revealed definite progress which was
confirmed by Alpha- fetoprotein levels.
Conclusion
Gd-EOB-DTPA MRI allows for a more precise assessment of
tumour response after Y90 therapy. The liver specific contrast agent enabled
earlier diagnosis of tumour progress compared to gadobutrol MR and also to
CT and can differentiate between therapy-induced changes and real tumour
progress.
B-0904 11:06
Use of high-relaxivity paramagnetic complex Mn-DCTA as contrast agent
for simultaneous MR-coronarography and contrast-enhanced MRI of the
heart
W.Y. Ussov, A.A. Bogunetsky, V.E. Babokin, M.L. Belyanin, S.G. Goltsov,
V.D. Filimonov; Tomsk/RU (
[email protected])
Purpose: The complex of manganese with trans-1, 2-diaminocyclohexane- N,
N, N', N'-tetraacetate (Mn-DCTA, ™Cyclomang) was tested as possible
contrast agent for simultaneous MR-coronarography and ECG-gated contrast-
enhanced MRI of myocardium.
Methods
and Materials: 21 patients with three-vessel coronary heart disease
comprised the study group and seven persons with normal coronary arteries
and minor left ventricle hypertrophy due to arterial hypertension were recruited
to control one. ECG- and breath-synchronised ssfp-coronarography has been
carried out in everybody for thr right coronary (RCA), left anterior descendent
(LAD) and left circumflex (LCx) coronary arteries. Also the CE-MRI of the heart
was performed in everybody. In all patients, the diagnosis was verified with
coronaroventriculography.
Results
The R1 relaxivity of Mn (II)-DCTA measured in saline as high as
R1=3.68 mM-1*s-1 did not differ significantly from the values obtained with
gadopentetate. The senisitivity of Mn-DCTA enhanced MR-coronarography
was, respectively, as high as: RCA 87%, LAD 92% and LCx89%. The
specificity was for the particular coronary arteries as follows: RCA 81%, LAD
86% and Lcx82%. The subsequent CE-MRI of the heart detected the areas of
non-transmural ischaemic myocardial damage for all walls of LV with
equivalent 98% sensitivity and 96% specificity . Both sensitivity and specificity
in transmural infarctions were 98.8%.
Conclusion
The non-gadolinium paramagnetic agent Mn-DCTA could be
suggested as acceptable contrast for complex "one-stop-shop" MRI evaluation
of both coronary vessels and myocardial ischaemic damage, without risk of
gadolinium toxicity.
S331
BA C D E F G
Monday
B-0905 11:15
Can Ferumoxytol be used as a contrast agent to differentiate between
acute and chronic inflammatory kidney disease? Feasibility study in a rat
model
J. Budjan, S. Neudecker, D. Schock-Kusch, N. Gretz, S.O. Schönberg,
H.J. Michaely, S. Haneder; Mannheim/DE (
[email protected])
Purpose: Ferumoxytol, an intravenous iron supplement, can be used as a
contrast agent in magnetic resonance imaging (MRI). Aim of this study was to
assess Ferumoxytol in animal models of acute and chronic inflammatory
kidney diseases.
Methods
and Materials: A total of 18 rats were examined: 6 healthy Sprague
Dawley rats as a control group; 6 rats with polycystic kidney disease (PKD) as
a model for chronic inflammatory disease; Thy-1, a antibody that triggers
glomerulonephritis was injected in 6 rats as a model for acute inflammation.
Each rat was examined using a clinical 3 T scanner (Magnetom Trio, Siemens)
and a dedicated rat coil (Rapid Biomedical) directly before and 24 hours after
intravenous administration of Ferumoxytol. Changes in relative T2 signal
intensity and T2*-times were measured. The rats' kidneys were histologically
examined.
Results
In the evaluation of the MRI scans, stati stically significant differences
between the three groups were found: Thy-1 rats showed the highest T2 signal
loss in the renal cortex (T2 signal intensity ratio after/before: Thy1 0.49, PKD
0.87, control 0.81; p=0.038). Thy1 and PKD rats showed statistically significant
changes of T2*-times compared to the control group (T2*-time ratio
after/before: Thy1 0.21, PKD 0.19, Control 0.28; p=0.002). MRI findings were
confirmed by histological analyses: stati stically significant differences in
Ferumoxytol particle count between the three groups were found.
Conclusion
Ferumoxytol-enhanced MRI allows detecting acute and chronic
inflammatory kidney disease with typi cal patterns of Ferumoxytol distribution.
Ferumoxytol thus might help to differentiate between different types of
inflammation in various kidney diseases.
B-0906 11:24
Solid phase peptide synthesis (SPPS) combined with the inverse Diels-
Alder reaction: a versatile tool for novel theranostic applications
D. Komljenovic, M. Wiessler, R. Pipkorn, W. Waldeck, R. Bangert,
W. Semmler, K. Braun; Heidelberg/DE (
[email protected])
Purpose: Development of novel diagnostic approaches in imaging of
molecular processes at the transcription level and synthesis of
pharmacologically active patient-specific metabolic components requires high
standards of safety, quality, and specifi city but also, rapid, efficient and
irreversible ligation routes. Here, we assessed the applicability of the inverse
Diels-Alder ligation reaction with inverse electron demand (DARinv) for
improved synthesis of novel diagnostic and therapeutic agents.
Methods
and Materials: We synthesized using SPPS a fluorescent dye
conjugate composed of a cell-penetrating peptide (CPP) facilitating the
passage across the cell membrane by "Click chemistry" ligation of the CPP
carrier and the fluorescent cargo component similar to Cy5. DU-145 and PC-3
cells were incubated for 15 minutes with the conjugate (12.5 M final
concentration), co-stained with DAPI and wheat germ agglutinin (WGA) and
investigated using CLSM for the detection of fluorescence signals.
Results
After incubation with the Cy5-labelled conjugate, both PC-3 and DU-
145 human prostate cancer cells revealed strong fluorescence signal in the
cytoplasm and in the perinuclear areas. Specific signals were observed as dot-
like areas scattered in particular in the proximity of the cell membrane as
visualised by WGA-staining (labeling membrane glycoproteins and glycolipids).
Conclusion
DARinv is an eligible ligation technology not only for prospective
medical applications e.g. patient-specifi c approaches, but also for selective
modification by functionalization of peptide-based polymers, organic and
inorganic surfaces and micro arrays. We conclude that ligation technology
based on DARinv has a high potential of becoming an important approach for
easier and faster molecular diagnostics and patient-specific therapy.
B-0907 11:33
Magnetic particle imaging (MPI): kinetics of the intravascular signal in
vivo
R.L. Duschka, J. Haegele, M. Graeser, K. Luedtke-Buzug, C. Schaecke,
N. Panagiotopoulos, T.M. Buzug, J. Barkhausen, F.M. Vogt;
Lübeck/DE (
[email protected])
Purpose: In magnetic particle imaging (MPI) image quality is determined by
the properties of the used superparamagnetic iron oxide nanoparticles
(SPIOs); thus, a long blood half-life of the SPIOs is desirable. The aim of this
study is to evaluate the blood half-life of the Resovist-induced MPI-signal.
Methods
and Materials: A dilution of Resovist (50 mol/kg) was administered
into the ear artery of ten fully anaesthetised New Zealand white rabbits. Blood
samples were drawn before and directly, 5, 10, 15 min and then every 15 min
after Resovist administration. Every blood sample was evaluated using
magnetic particle spectroscopy. The decay of the MPI signal was calculated for
each time point.
Results
The highest spectral MPI signal was measured directly after
Resovist® administration (1.79*10^-8 Am^2 Hz^-1). After application of
Resovist the signal decreased to 30.0 % within 5 min and to 14.8 % and 7 %
within 10 and 15 min, respectively. Within 30 min, the measured signal was
below the background noise level.
Conclusion
The decrease of the intravenous signal is faster than the blood
half-life of Resovist determined by MRI. This might be explained by the faster
blood-clearance of the fraction of larger particles and particle aggregates
contributing to the better part of the MPI-signal in comparison to the smaller
particles which only contribute a small part of the MPI-signal. Additionally,
because of the higher sensitivity of the MPS-system compared to the current
MPI-scanners, the visualisation of blood vessels will be possible for an even
shorter time period.
B-0908 11:42
Comparative in vitro dissociation of gadolinium chelates in human serum
measured by relaxometry
N. Fretellier, J.-M. Idee, G. Jestin-Mayer, M. Rasschaert, C. Factor, C. Corot;
Roissey-Charles-de-Gaule/FR (
[email protected])
Purpose: Assessment of the stability of all marketed categories of gadolinium
chelates (GC), in human serum at 37 °C.
Methods
and Materials: GCs gadoterate (Dotarem®), gadopentetate
(Magnevist®), gadobenate (MultiHance®) and gadodiamide (Omniscan®) (1
mM) were incubated in human serum for 15 days, with or without addition of 10
mM phosphate, at 37 °C. Relaxation times T
1 were measured (Minispec mq60
Bruker relaxometer) at 60 MHz. Relaxation rates R 1 (s -1) were calculated
(R1=1/T1). The influence of serum proteins on gadodiamide dissociation was
investigated by ultrafiltrating the samples.
Results
A marked increase in the R 1 relaxation rate value over the time was
observed only after incubation of gadodiamide in serum (+49 %/+78% at day
15 without/with phosphate, versus T0), suggesting a gradual dissociation for
this GC. After incubation of gadopentate or gadobenate, a slight increase in R 1
value was also observed. This increase in R 1 value was greater and faster after
adjustment of phosphate concentration to 10 mM (+5%/+9% and +9%/+14%,
without/with phosphate, respectively, at day 15). For the macrocyclic GC
gadoterate, R 1 values remained stable throughout the study, indicating the
absence of dissociation. Serum ultrafiltration completely inhibited gadodiamide-
induced increase in R
1 value.
Conclusion
Our data indicate a gradual in vitro dissociation with gadodiamide
and binding of dissociated and soluble Gd 3+ to serum proteins (an effect
facilitated by phosphate anion). The macrocyclic GC gadoterate remained
stable over 15 days.
Author Disclosures:
N. Fretellier: Employee; Guerbet. J. Idee: Employee; Guerbet. G. Jestin-
Mayer: Employee; Guerbet. M. Rasschaert: Employee; Guerbet. C. Factor:
Employee; Guerbet. C. Corot: Employee; Guerbet.
B-0909 11:51
TOF MRA versus ultra-low-dose contrast-enhanced MRA at 7T
L. Umutlu, A. Fischer, M. Forsting, M. Ladd, S. Maderwald, O. Kraff,
T.C. Lauenstein; Essen/DE (
[email protected])
Purpose: The aim of this trial was to compare the diagnostic ability of non-
enhanced (TOF) versus ultra-low-dose contrast-enhanced renal MRA at 7
Tesla.
Methods
and Materials: 10 healthy subjects were examined on a 7T MR
system (Magnetom 7T), utilising a custom-built 8-channel RF body coil. For
non-enhanced renal MRA Time-of-flight (TOF) datasets with a voxel size of 1.0
x 2.0 x 2.5 mm3 were obtained. For ultra-low-dose contrast-enhanced (ce)
renal MRA, dynamic 3D FLASH data sets (voxel size 1.0 x 1.5 x 1.0 mm3)
were obtained unenhanced and in arterial phase after the application of
0.025 mmol/kg BW Gadobutrol (Bayer Healthcare). Image subtraction was
performed subsequently. Contrast ratios (CR) were measured in the aorta and
both renal arteries in correlation to adjacent psoas major muscle. Qualitative
analysis with regard to delineation of the renal arterial vasculature was
performed by two radiologists using a five-point-scale (5=excellent to 1= non
diagnostic).
Results
vasculature. Qualitative analysis revealed comparable results of
vessel conspicuity in subjective ratings for non-enhanced (mean left renal
artery = 4.4) and subtracted contrast-enhanced datasets (mean left renal artery
= 4.7). Background suppression in subtracted datasets was superior to
Background
suppression of TOF-images, reflected in superior contrast ratio
values for subtracted datasets (mean aorta =0.74) compared to TOF-MRA
(mean aorta = 0.45).
S332
BA C D E F G
Monday
Conclusion
Preservation of high-image quality while facilitation of significant
reduction, or respectively complete omission of contrast agent, may be of high
diagnostic value for MR angiographic examinations in patients with renal
impairment.
14:00 - 15:30 Room A
Cardiac
SS 1803
Myocardial perfusion and late
enhancement: CT
Moderators:
G. Balázs; Budapest/HU
E. Mershina; Moscow/RU
B-0910 14:00
Incremental value of pharmacological stress dual-energy cardiac CT over
coronary CT angiography alone for the assessment of coronary artery
disease in a high-risk population
C. De Cecco, U.J. Schoepf, A.W. Krazinski, A. Bucher, A.D. McQuiston,
F.G. Meinel; Charleston, SC/US (
[email protected])
Purpose: To prospectively determine the value of stress dual-energy CT
(DECT) myocardial perfusion imaging to coronary CT angiography (cCTA) for
the assessment of coronary artery disease (CAD) in a high-risk population.
Methods
and Materials: We prospectively enrolled 29 consecutive patients
who were referred for cardiac SPECT examinations for known or suspected
CAD to additionally undergo pharmacological stress cardiac DECT. In 25
patients cardiac catheterization was available as the reference standard for
morphologically signific ant stenosis. The performance of CCTA alone, DECT
myocardial perfusion alone and the combination of both was assessed by
calculating sensitivity, specificity and area under the curve (AUC) values.
Results
For morphologically significant ste nosis, cCTA alone and myocardial
DECT assessment alone had 95% sensiti vity and 50% specificity. The
combined approach yielded 100% sensitivi ty at 33% specificity if either was
positive and 90% sensitivity at 67% specifi city if both were positive. The AUC
value was highest (0.78) if both were positive. For hemodynamically significant
lesions, cCTA alone had 91% sensitivity at 38% specificity and DECT alone
had 95% sensitivity and 75% specificity. The combined approach yielded 100%
sensitivity at 38% specificity if either was positive and 86% sensitivity at 75%
specificity if both were positive. AUC values were highest for DECT alone
(0.85) and the "both positive" evaluation (0.80).
Conclusion
The combined analysis of cCTA and DECT myocardial perfusion
reduces the number of false positives in a high-risk population for CAD and
outperforms the purely anatomical test of cCTA alone for the detection of
morphologically and hemodynamically significant CAD.
B-0911 14:09
Quantitative analysis of dynamic CT myocardial perfusion imaging in a
large, multi-center patient population
F.G. Meinel
1, C.N. De Cecco1, F. Bamberg2, U. Ebersberger1, U.J. Schoepf1,
G.G. Lo3, Y. Wang4, J.A. Maivelett1; 1Charleston, SC/US, 2Munich/DE,
3Hong Kong/CN, 4Beijing/CN (
[email protected])
Purpose: To determine the accuracy of quantitative measurements of
myocardial blood flow (MBF), myocardial blood volume (MBV) and volume
transfer constant (K trans) derived from stress dynamic CT myocardial perfusion
(CTMP) imaging to differentiate between myocardium with and without
perfusion defects.
Methods
and Materials: We retrospectively analysed CTMP datasets from
146 patients from 5 centres who underwent coronary CT angiography (CCTA)
and CTMP imaging. CCTA datasets were evaluated for the presence of
coronary stenosis on a per-vessel basis. In correlation with the CCTA, CTMP
datasets were visually evaluated for perfusion defects in each vessel territory.
For the quantitative analysis, regions of interest were placed in the
myocardium of each vessel territory to obtain MBF, MBV and K
trans.
Results
The areas under the receiver operating characteristic curves (AUCs)
to discriminate between vessel territori es with and without perfusion were
0.964 for MBF, 0.967 for MBV and 0.849 for K trans. The optimal cutoffs were
88 mL/100 mL/min for MBF, 15 mL/100 mL for MBV and 69 for K trans.
Sensitivity and specificity for myoc ardial perfusion defects were 93% and 98%
for MBF and 95% and 91% for MBV, respectively.
Conclusion
MBF and MBV measurements on dynamic CT myocardial
perfusion imaging can differentiate between myocardial territories with and
without perfusion defects with high discriminatory power.
Author Disclosures:
U.J. Schoepf: Consultant; Bayer, Bracco, GE, Medrad, Siemens.
B-0912 14:18
Evaluation of accuracy for detection and extent of occult myocardial
scars using delayed-enhancement CT in patients with asymptomatic
diabetes: results from the ACCREDIT study
J.-W. Kang
1, S. Choi2, S. Ko1, T.-H. Lim1; 1Seoul/KR, 2Seongnam-Si/KR
(
[email protected])
Purpose: To evaluate the accuracy of delayed-enhancement CT (DE-CT) for
detecting occult myocardial scars (OMS) and to evaluate the transmurality of
OMS using DE-CT compared with delayed enhancement MRI (DE-MRI) in
asymptomatic patients with type 2 diabetes.
Methods
and Materials: DE-MRI and DE-CT were respectively performed
with gadoterate meglumine and Iobitridol on 167 patients. Image quality of DE-
CT was evaluated. The prevalence and the transmurality of OMS on both DE-
MRI and DE-CT at patient level and segment level were evaluated. The
accuracy of DE-CT for detecting OMS was evaluated in comparison with DE-
MRI both at patient and segment level. The transmurality of OMS in DE-CT
and DE-MRI for each scar was assessed in terms of over- or underestimation
of DE-CT.
Results
The image quality of DE-CT was good and adequate in 165 (98.8%)
patients. The OMS was detected in 12 (7.3%) by DE-MRI and 7 (4.3%) by DE-
CT. Of the 2788 segments, OMS was detected in 24 segments on DE-MRI and
in 12 segments on DE-CT. The sensitivity , specificity, positive and negative
predictive value of DE-CT for detecting OMS was 58.3%, 100%, 100%, and
96.8% at patient level, and 50%, 100%, 100%, and 99.6% at segment level.
The grade for transmurality of OMS between DE-CT and DE-MRI was matched
at segment level in 41.7%, under-evaluation of transmurality on DE-CT was in
54.2%.
Conclusion
The sensitivity of DE-CT for detecting OMS is moderate, but the
specificity is high. Under-evaluation of the transmurality of OMS is common
using DE-CT.
Author Disclosures:
J. Kang: Research/Grant Support; Guerbet Group, France. S. Choi:
Research/Grant Support; Guerbet Group, France. S. Ko: Research/Grant
Support; Guerbet Group, France. T.-H. Lim: Research/Grant Support; Guerbet
Group, France.
B-0913 14:27
Quantitative evaluation of novel beam-hardening artefact correction
technique in dual-energy CT perfusion imaging of the myocardium
A.M. Bucher1, L.L. Geyer2, U.J. Schoepf1, T.J. Vogl3, J.M. Kerl3,
A.W. Kazinski1, A.J. Lewis1, F.G. Meinel1, C.D. Wolla1; 1Charleston, SC/US,
2Munich/DE, 3Frankfurt am Main/DE (
[email protected])
Purpose: In cardiac dual energy CT (cDECT) perfusion imaging, contrast
medium filling of the left ventricle and descending aorta and the spine are
relevant sources of beam-hardening artefacts (BHA) impeding diagnostic
evaluation of myocardial regions for perfusion defects. The purpose of this
study was to quantitatively assess the impact of a novel Kernel (D33f) with
implemented beam hardening correction on BHA of the myocardium.
Methods
and Materials: Rest series of cDECT perfusion examination from 14
patients were retrospectively analysed. Six reconstructions were performed for
each patient with 3.0 mm section thickness: a) 100 kV b) 140 kV c) mixed
image, each with (D33f) and without (D30f) BHA correction kernel. 792
myocardial regions of rest studies were compared. Regions of interest (ROI),
traced by a reader, equally subdivided the myocardium in the axial slice where
BHA was most visually prevalent. This individual ROI mask was copied onto all
corresponding series. Three subdivisions were made within areas of BHA.
Paired student t-test was used for statistical evaluation.
Results
Myocardial attenuation signi ficantly differed on corrected
reconstructions (D30f 85.1 HU ± 82.9-87.3; D33f 89.2 HU ± 87.0-91.4,
p < 0.001). Relative difference from average myocardial attenuation
significantly differed within visu ally chosen ROIs (D30f 21.9% ± 18.6-25.2%;
D33f 11.1% ± 9.3-12.8% p < 0.001). RD
TM difference was greatest for BHA
occurring in the infero-lateral basal myocardium (D30f 30.7% ± 26.5-34.9%;
D33f 11.5% ± 8.7-14.3% p < 0.001).
Conclusion
D33f kernel application in post-processing of cDECT perfusion
studies can significantly reduce BHAs, improving myocardial perfusion defect
assessment.
Author Disclosures:
U.J. Schoepf: Research/Grant Support; Bayer, GE, Bracco, Medrad,
Siemens.
S333
BA C D E F G
Monday
B-0914 14:36
CT evaluation of myocardial extracellular volume in patients with chronic
myocardial infarction: a novel approach for objective assessment of
myocardial viability
Y. Kurita, K. Kitagawa, T. Ito, N. Nagasawa, H. Nakajima, S. Nakamori,
M. Ishida, H. Sakuma; Tsu/JP (
[email protected])
Purpose: Myocardial viability is commonly evaluated by assessing extent of
delayed enhancement (DE) which depends on choice of threshold value. CT
assessment of extracellular volume (ECV) is a new approach towards
quantitative evaluation of myocardial scar. The purpose of this study was to
investigate if ECV quantified in each myocardial segment could be used for
Objective
assessment of myocardial viability.
Methods
and Materials: Pre-contrast and delayed-phase CT were obtained in
20 patients with chronic myocardial infarction by using a dual-source CT.
Delayed-phase CT was reconstructed with a targeted spatial frequency
filtration (TSFF) algorithm to obtain stable attenuation of the myocardium. ECV
was calculated with the following equation: ECV=( ,HUm / ,HUb)(1Hct),
where ,HUm and ,HUb is the change in attenuation of the myocardium and
the LV blood, respectively, before and after contrast administration. Extent of
DE by visual assessment and ECV were determined in each of 16 myocardial
segments.
Results
There was a significant segment-based linear relationship between
extent of DE and ECV (y=0.20x+27.0, r 2=0.58), with ECV of 27%, 32%, 37%
and 42% corresponding to DE extent of 0%, 25%, 50% and 75%, respectively.
ROC curve analysis demonstrated AUC of 0.962 for detecting segments with
DE of > = 50%, with sensitivity of 91% and sp ecificity of 92% with threshold
ECV of 34.5%. High inter-observer reproducibility was found in measuring
ECV, with intraclass correlation coefficient of 0.898.
Conclusion
Accurate and objective assessment of myocardial viability can be
performed by using ECV determined by dual-source CT with TSFF algorithm in
patients with chronic myocardial infarction.
Author Disclosures:
H. Sakuma: Research/Grant Support; Siemens Japan, Bayer.
B-0915 14:45
Diagnostic accuracy of late iodine enhancement on cardiac DSCT with
denoise filter in the evaluation of myocardial infarction
T. Matsuda1, T. Kido1, T. Itoh2, S. Shigemi3, H. Saeki3, K. Watanabe3,
T. Matsuda3, M. Yamamoto3, T. Mochizuki1; 1Toon/JP, 2Tokyo/JP,
3Matsuyama/JP
Purpose: We evaluated diagnostic accuracy of the late myocardial
enhancement (LME) on a dual-source CT (DSCT) with both a denoise filter
and an improved injection protocol (LIE-CT), by comparing with the late
gadolinium enhancement on MRI (LGE-MR).
Methods
and Materials: In 18 patients with acute myocardial infarction, DSCT
and 1.5 T MRI were performed within 3 weeks. After the coronary CTA, an
additional contrast medium with a slow injection rate (50 ml, 12 ml/min) was
added, and then the LIE-CT was performed. To reduce image noise, we
applied an iterative 3D denoise filter to LIE-CT images. Detectability of LME
with LIE-CT and LGE-MR was compared. Infarct area was assessed as
percentage of the myocardium. The CT value ratios were calculated as
contrast enhancement of myocardium divided by that of left ventricular cavity.
Results
LME was detected in 17/18 patients in LGE-MR and 15/17 patients in
LIE-CT. LIE-CT areas (mean=9.4%) correlated well with those of LGE-MR
(mean=10.3%). Mean CT values of normal and infarction areas were
75.4 ± 12.5 HU and 108.12 ± 19.1 HU, respectively. Mean CT value ratios of
the normal and the infarction areas were 0.45 ± 0.16 and 1.09 ± 0.56,
respectively. Mean CT value and mean CT value ratio of the infarction areas
were significantly higher than those of the normal areas, respectively
(p < 0.001).
Conclusion
Late myocardial enhancement areas on both DSCT and MRI are
correlated well. DSCT with the denoise filter and the additional slow contrast
medium injection protocol can improve the diagnostic accuracy.
Author Disclosures:
T. Itoh: Employee; Siemens Japan.
B-0916 14:54
Myocardial dynamic perfusion imaging with DSCT: a comparative study
with magnetic resonance imaging
A. Grande, C. Delgado, C. Trinidad, R. Oca, A. Fernandez del Valle, A. Bustos;
Vigo/ES (
[email protected])
Purpose: To evaluate the feasibility of adenosine-stress dynamic myocardial
volume perfusion imaging with second generation dual source computed
tomography (DSCT) for the qualitative and quantitative assessment of
myocardial blood flow (MBF) compared with stress perfusion and viability
magnetic resonance imaging (MRI).
Methods
and Materials: Prospective study including 13 patients (10 male, 3
female, mean age 61.2 ± 8.69 years) who underwent stress/rest perfusion and
delayed-enhancement MRI, and a cardiac DSCT protocol: 1. Dynamic
adenosine-stress myocardial perfusion imaging using a "shuttle" mode
2. Coronary CT angiography. 3. Delayed enhancement acquisitions. Two
independent observers visually assess ed myocardial perfusion defects and
quantified perfusion values of segments with and without defects.
Results
A total of 221 segments were analysed. Sensitivity, specificity,
positive and negative predi ctive values for detection of myocardial perfusion
defects at CT compared with MRI were 63%, 99%, 85%, and 96%,
respectively. Quantitative assessment show ed myocardial blood flow values of
82.4 ± 26.2 ml/100 ml/min and 125.3 ± 43.6 ml/100 ml/min for ischemic and
nonischemic segments respectively, existi ng significant differences. Mean total
dose length product for the entire cardiac CT protocol was 9.85 ± 2.5 mSv.
Conclusion
DSCT is able to obtain qualitative and quantitative images of
dinamic myocardial perfusion. Diagnostic accuracy is acceptable, although with
lower sensibility values compared with other publications, specially in the study
of myocardial viability. More studies are needed to set the real diagnostic
accuracy of this technique.
B-0917 15:03
Early myocardial gadolinium enhancement in patients with myocarditis:
validation of "Lake Louise consensus" criteria using a single bolus of
0.1 mmol/Kg of a high relaxivity gadolinium-based contrast agent
N. Galea, I. Carbone, G. Cannavale, V. Noce, C. Catalano, M. Francone;
Rome/IT (
[email protected])
Purpose: Early gadolinium enhancement (EGE) has been indicated as major
CMR criterion for the diagnosis of myocarditis according to the Lake Louise
consensus (LLC). However, the suggested threshold of 4.0 for early
enhancement ratio (EER) specifically refers to use of conventional Gd-chelates
(gadopentetate dimeglumine). Our purpose was to evaluate performance of a
high relaxivity contrast agent (gadobenate dimeglumine) for the detection of
EGE applying the suggested cut-off.
Methods
and Materials: Fifty-seven consecutive patients with a histologically
proven diagnosis of acute myocarditis and 18 controls performed a CMR study
on a 1.5 T unit. CMR protocol included: T2w-STIR sequences, early
gadolinium enhancement (EGE) and late gadolinium enhancement (LGE)
technique after a single bolus of 0.1 mmol/Kg Gd-BOPTA. For each study early
myocardial enhancement ratio was calculated as follows: early gadolinium
enhancement ratio = enhancement myocardium/enhancement skeletal muscle.
In patients with evidence for skeletal muscle involvement, an absolute
myocardial enhancement of more than 45% was considered as diagnostic
criterion. Receiver operating characteri stic (ROC) curve analysis was applied
on the overall population.
Results
EGE was present in 35 patients with myocarditis. Applying the EGE
threshold proposed by LLC (EER value > 4.0) to the ROC curve, sensitivity and
specificity of, respectively, 60.7% and 88.9% (area under curve: 0.722) were
observed. These results are comparable to those obtained using
gadopentetate dimeglumine reported in literature.
Conclusion
Use of Gd-BOPTA provides comparable results to conventional
Gd-chelates regarding the application of EGE suggested thresholds for the
diagnosis of acute myocarditis and it is therefore applicable in daily clinical
routine.
B-0918 15:12
Comparison between unenhanced and contrast-enhanced post-mortem
CT for diagnosis of death by cardiovascular events at virtual autopsy
J.C. Apitzsch
1, S. Westphal2, T. Penzkofer2, R. Knüchel-Clarke2,
A.H. Mahnken1; 1Marburg/DE, 2Aachen/DE (
[email protected])
Purpose: To evaluate the value of contrast-enhanced post-mortem CT in
comparison to non-enhanced post-mortem CT in the detection of
cardiovascular causes of death and the clinical value of the method.
Methods
and Materials: In a prospective study, 21 corpses were examined
using multislice computed tomography before and after intraarterial perfusion
contrast agent with a CT-value of 300 HU and ventilation of the lungs. CT-
values were measured in the following locations: left ventricle, descending
aorta, common carotid arteries, common iliac arteries and popliteal arteries.
The cause of death was determined in enhanced and unenhanced scans and a
level of confidence was given. Results were compared to autopsy results as
gold standard.
Results
Intraarterial perfusion resulted in a very homogeneous arterial
contrast enhancement with equally 300 HU in every of the mentioned
locations. No extravasation due to methodical failures or shunting into the
venous system occurred. The method allowed visualisation of different types of
cause of death. Unenhanced and enhanced scans were compared and the
Results
compared to those of conventional autopsy. There was a significant
improvement in LOC in enhanced scans compared to unenhanced scans as
well as an improvement in the detection of COD.The ventilation of the lungs
S334
BA C D E F G
Monday
inflated and distended the thorax, making diagnoses easier. The COD could be
determined in 20 out of 21 patients.
Conclusion
Post-mortem contrast-enhanced CT is feasible and appears to be
robust for diagnosing cardiovascular causes of death. When compared with
unenhanced post-mortem CT intraarterial perfusion and pulmonary ventilation
significantly improve visualisation and diagnostic accuracy.
B-0919 15:21
Diagnostic accuracy of myocardial perfusion assessment using
computed tomography in comparison to SPECT and ICA: a meta-analysis
G. Pelgrim, X. Xie, M.D. Dorrius, A. Handayani, M. Den Dekker, M. Oudkerk,
R. Vliegenthart; Groningen/NL (
[email protected])
Purpose: To determine the diagnostic accuracy of perfusion computed
tomography (CT) in rest and stress for the detection of significant coronary
artery disease (CAD), using single photon emission computed tomography
(SPECT) and invasive coronary angiography (ICA) as a reference standard.
Methods
and Materials: Pubmed, Embase and Web of Knowledge were
searched until March, 2013. Two reviewers independently screened 5,110
records regarding diagnostic accuracy of CT perfusion in rest and stress,
based on title and abstract. Two reviewers then assessed the full-text of the
resulting 390 studies for inclusion and extracted information. True-positive,
true-negative, false-positive and false-negative numbers were extracted for
diagnostic performance. The studies were grouped according to CT perfusion
technique and reference method. Patient-based results were pooled using a
random effects model. Statistical analysis required at least 4 studies using
equal methodology to be included.
Results
In total, 11 studies (744 participants) of the total 5,110 were included.
For rest CT perfusion, 6 out of these 11 studies were pooled (457 participants).
Pooled sensitivity and specificity for ischaemia was 0.87 (0.77, 0.93) and 0.88
(0.79, 0.94) compared to rest SPECT. Regarding stress CT perfusion, 5 out of
the 11 studies were pooled (287 participants) with ICA as reference standard.
Pooled sensitivity and specificity for stress CT perfusion was 0.86 (0.64, 0.95)
and 0.90 (0.57, 0.98) compared to ICA.
Conclusion
CT perfusion techniques and reference standards vary in current
literature. Based on limited studies, CT perfusion techniques seem sensitive
and specific for diagnosis of significant CAD compared to ICA and SPECT.
B-0920 15:30
Comparison study of the rest and adenosine stress of myocardial
between CT perfusion and SPECT in CHD
S. Ou, S. Li, s. Ou, F. Long, H. Lin; Guangzhou/CN (
[email protected])
Purpose: The aim of this study was to determine the agreement of adenosine
stress CTP and SPECT-MPI under rest and stress including every segment
and vessel in CHD.
Methods
and Materials: 47 patients underwent a nuclear stress test in 3
months in the study. DECT was performed as follows: 1. stress CT of contrast-
enhanced scan during adenosine infusion. 2. rest CT of contrast-enhanced
scan by prospective triggering. Perfusion defect was graded as transmural
(炪50%) versus nontransmural ( 炩50%). CTPI and SPECT were completed by
2 independent and 5 years experienced radiologists.
Results
47 subjects (average age 61.4+ 10.7 years; An average radiation
dose of 12.7 mSv of per CTP. CTP had a sensitivity of 78% and a specificity of
81% for the vessel stenosis of 50%, whereas SPECT myocardial perfusion
imaging had a sensitivity of 66% and a specificity of 83% (P=0.442 in
sensitivity, P=0.864 in specificity). When stenosis of 70% by CTA was used
as the reference standard,the sensitivity and specificity were 84% and 68% by
CTP, but 71% and 73% by SPECT (P=0.564 in sensitivity, P=0.688),
respectively.
Conclusion
Adenosine stress CTP can identify the accuracy of stress-
induced myocardial perfusion defects compared to SPECT and provide more
information on coronary stenosis in CHD.
14:00 - 15:30 Room B
Abdominal Viscera
SS 1801a
Advances in CT
Moderators:
S.T. Schindera; Basle/CH
J. Votrubova; Prague/CZ
B-0921 14:00
Sequential contrast-enhanced CT analysis of reduction effect on
multicentric type recurrence of HCC with Peretinoin
S. Kobayashi, T. Gabata, O. Matsui, W. Koda, T. Minami, K. Kozaka, A. Kitao,
N. Yoneda, K. Yoshida; Kanazawa/JP
Purpose: To evaluate the reduction of multicentric type recurrence (MC
recurrence) with Peretinoin, an acyclic retinoid, in patients previously treated
for HCC with sequential contrast-enhanced CT (CECT) images.
Methods
and Materials: After curative resection or ablation for HCC, patients
received either Peretinoin 600 mg/day (the high-dose group, H), 300 mg/day
(the low-dose group, L) or placebo (P). Total 210 cases showed recurrence of
HCC (H, 53; L, 80; P, 77) during follow-up period. Among the recurrent
hypervascular HCCs, nodules which appeared in the point where hypovascular
hepatic nodules were previously observed and regarded to be multistep
hepatocarcinogenesis on follow-up sequential CECT images are defined to be
MC recurrence of HCC. The cumulative MC recurrence free survival (MCRFS)
rates were calculated. Hazard ratio (HR) was calculated using Cox regression
analysis.
Results
MC recurrence occurred in 43 cases (H n=6; L, n=18; P, n=18).
MCRFS rates in H were higher than those in P or L (during the first year, H,
95.8%; L, 93.6%; P, 94.2%: during the 2 years, H, 90.1%; L, 86.0%; P, 81.4%:
during the 3 years, H, 90.1%; L, 78.2%; P, 69.5%). No events occurred in H
after 2 years of enrollment. The HR (H vs. P) for 3 years was 0.41 (95% CI,
0.16 to 0.93). The HR (L vs. P) for 3 years was 0.99 (95% CI, 0.51 to 1.92).
Conclusion
Analysis of sequential CECT could show that Peretinoin
600 mg/day reduced the MC recurrence of HCC.
Author Disclosures:
O. Matsui: Advisory Board; KOWA Company, LTD.
B-0922 14:09
Effect of reconstruction algorithm on semi-automated quantification of
liver lesion size and density at MDCT
V. Yaghmai, F.D. Gonzalez-Guindalini, A.R. Seyal, K. Parekh; Chicago, IL/US
(
[email protected])
Purpose: To evaluate the effects of Filtered Back Projection (FBP) and
Sinogram Affirmed Iterative Reconstruction (SAFIRE) on liver lesion size and
density using semi-automated quantification.
Methods
and Materials: This HIPAA compliant retrospective study was IRB
approved. Fifteen oncology patients with 30 hypodense liver metastases who
had undergone a CT scan of the abdomen and pelvis were evaluated. The
scans were simultaneously reconstructed using two different algorithms:
Filtered Back Projection (FBP - Protocol 1) and Sinogram Affirmed Iterative
Reconstruction (SAFIRE - Protocol 2). Lesion largest diameter (RECIST), bi-
dimensional diameters (WHO) and volume, as well as the whole lesion density
were obtained using semi-automated software and were compared. Wilcoxon
signed-rank test was used for analysis. P < 0.05 was considered significant.
Results
Lesion size measurements did not change between different
reconstruction algorithms. The median largest diameters for protocols 1 and 2
were 2.3 cm (IQR: 1.4) and 2.3 cm (IQR: 1.4) (P=0.55). The bi-dimensional
measurements were 3.9 cm
2 (IQR: 4.9) and 3.8 cm 2 (IQR: 5) for protocols 1
and 2, respectively (P=0.7). Volumetry was also comparable between protocol
1 and protocol 2 with P=0.9 (3.6 cm
3 - IQR: 6.7 vs. 3.5 cm 3 - IQR: 6.0,
respectively). Lesion density values were similar in both protocols, P=0.47
(71.5 HU - IQR: 60 HU vs. 76 HU - IQR: 63 HU).
Conclusion
CT reconstruction algorithm did not affect the semi-automated
quantification of size and density of liver metastasis.
Author Disclosures:
A.R. Seyal: Research/Grant Support; Educational Grant Support from
Siemens Healthcare. K. Parekh: Research/Grant Support; Educational Grant
Support from Siemens Healthcare.
S335
BA C D E F G
Monday
B-0923 14:18
Automatic tube voltage selection and combined SAFIRE reconstruction:
the application research in the enhanced abdominal scan
R. Zhang, B.J. Gao; Zhengzhou/CN (
[email protected])
Purpose: To investigate the value of automatic tube voltage selection (CARE
kV) and combined with sinogram-affirmed iterative reconstruction (SAFIRE)
technology in improving image quality and reducing radiation dose in the
abdominal imaging.
Methods
and Materials: Retrospective analysis,70 patients underwent
contrast-enhanced abdominal CT and randomly divided into 2 groups. 35
patients were assigned to study group, using the tube voltage of CARE kV,
reconstructed with FBP (protocol A) and SAFIRE (protocol B), respectively; 35
patients were assigned to control group, using the tube voltage of 120 kVp,
reconstructed with FBP (protocol C). Assess the radiation dose (CTDIvol, DLP,
ED), the mean image noise, contrast-to-noise ratio (CNR) and signal-to-noise
ratio (SNR) relative to muscle for liver, pancreas, kidney, aorta and portal vein
with each protocol. A five-point scale was used to evaluate the subjective of
image quality. The statistical analysis method includes: paired-sample t test,
independent-samples t test and Wilcoxon test.
Results
ED in the study group and control group is (3.90 ±0.37, 4.93± 0.41)
mSv, reduced by 20.89%. The subjective rating scores in protocol A/B/C in
arterial and venous phase were (3.65 ±0.08, 3.57±0.08), (4.41±0.10, 4.41±0.10)
and (3.79 ±0.10, 3.95± 0.11) point (P < 0.001). The image noise of protocol
A/B/C in dual-phase were (11.96± 0.33, 12.79 ±0.39), (8.45 ±0.26, 9.14± 0.36)
and (10.38 ±0.26, 11.13 ±0.18) HU (P < 0.001). SNRs and CNRs in protocol B
were the highest of three protocols (P < 0.001). No statistically significant
differences between protocol A and C in SNRs and CNRs.
Conclusion
Use of CARE KV technology alone can reduce the radiation dose
but increase image noise; the combination use of SAFIRE reconstruction
technique can reduce dose and improve image quality.
B-0924 14:27
Generating normal reference values for examinations of the liver using
acoustic radiation force impulse virtual touch tissue quantification (ARFI-
VTTQ) elastography and comparison with acoustic radiation force
impulse virtual touch imaging and quantification (ARFI-VTIQ)
elastography: first results of a pilot study
T. Graeter, S. Galgenmueller, W. Kratzer, M. Beer, S. Oeztuerk, M. Haenle,
A. Akinli; Ulm/DE (
[email protected])
Purpose: Virtual touch tissue quantificati on (VTTQ) and virtual touch imaging
and quantification of acoustic radiation force impulse (ARFI) permits
quantitative measurement of tissue el asticity. Reliable use of these methods
for assessing pathological changes in hepatic tissue requires establishment of
normal reference ranges for findings returned by ARFI-VTTQ and ARFI-VTIQ
in the healthy liver.
Methods
and Materials: After excluding patients with known history of liver
disorders, a total of 188 volunteers (57.4%, women; 42.6%, men; mean age,
31.1±13.0 years) were examined. All patients were examined in the right MCL
cranially and caudally, and in the right and left liver lobes using the 6C1 (ARFI-
VTTQ) and 9L4 (ARFI-VTIQ) transducers. ARFI-VTIQ measurements were
examined in 15 and 25 mm and ARFI-VTTQ measurements in 5 cm depth.
Results
ARFI-VTTQ showed a mean value of 1.3 ±0.2 m/s (range=0.9-2.1).
The difference in ARFI-VTTQ values between men and women was statistically
significant (p <.0001). Significant correlation of ARFI-VTTQ values with age
was observed (p=0.0.0281). ARFI-VTTQ values were not higher in female
subjects using oral contraceptive steroids (p=0.8823).There was, however, a
statistical significant correlation between ARFI-VTIQ and ARFI-VTTQ values.
Additionally, ARFI-VTIQ values for measurements near with liver capsule were
significantly higher than those for measurements of deeper measurement
regions.
Conclusion
ARFI-VTTQ and ARFI-VTIQ values in healthy hepatic
parenchyma can be influenced by many factors. Differences between the two
transducers used in the present study are related to physical factors. The study
could serve as the basis for further studies of measurements in pathologically
altered hepatic parenchyma.
B-0925 14:36
Hypodense liver lesions in patients with steatosis hepatis: do we profit
from the additional image information of dual-energy computed
tomography?
J. Nattenmüller, W. Hosch, T.T. Nguyen, L. Grenacher, H.-U. Kauczor,
C.M. Sommer, W. Stiller; Heidelberg/DE (
[email protected])
Purpose: To assess potential benefits of dual-energy CT (DECT) for imaging
of hypodense liver lesions in patients with steatosis hepatis with regard to
Objective
image quality (IQ).
Methods
and Materials: 105 patients with steatosis hepatis underwent DECT
(portal-venous phase) with reconstruction of 4 different datasets: pure iodine
(PI), optimum contrast (OC), 80 kVp, and 120 kVp-equivalent (linear blended
dataset: 30% 80 kVp, 70% 140 kVp; M0.3). Objective image quality was
evaluated by determining image noise (IN) in liver parenchyma, hypodense
liver lesion, muscle, lesion-to-liver signal-to-noise (SNR) and lesion-to-liver
contrast-to-noise (CNR) ratios, and comparing these by one-way-ANOVA /
Dunn's-Multiple comparison test. Intra- and inter-observer agreement (2
observers, each performing 2 independent ROI-measurements) was
determined by Bland-Altman-Analysis. Average effective radiation dose (ERD)
was determined.
Results
21 patients with hypodense liver lesions were identified. IN for liver
parenchyma, hypodense lesion, and muscle was lowest in PI (6.7/6.9/7.6 HU)
followed by M0.3 (11.9/12.9/13.6 HU), and OC (16.7/13.5/16.3 HU), highest in
80 kVp (20.5/22.1/21.9 HU). SNR was highest in PI (1.3), followed by M0.3
(0.72), and 80 kVp (0.63), lowest in OC (0.55). CNR was highest in M0.3
(4.95), followed by OC (4.55), and 80 kVp (4.1), lowest in PI (3.63). Intra- and
inter-observer agreement was high for all IQ parameters. ERD was 5.45mSv
(3.48 - 10.16mSv).
Conclusion
Highest overall objective IQ for depicting hypodense liver lesions
in patients with steatosis hepatis was found for 120 kVp-equivalent images.
Therefore, DECT does not seem necessary for these patients despite
additional image information offered by DECT, especially given the potentially
increased radiation exposure compared with 'single-energy' CT at 120 kVp.
B-0926 14:45
Diagnostic performance of liver imaging in patients with suspected
colorectal liver metastases: the superiority of MRI
A. Schulz, E. Viktil, J.C. Godt, C.K. Johansen, J.B. Dormagen, J.E. Holtedahl,
K.J. Labori, T. Bach-Gansmo, N.E. Kløw; Oslo/NO
(
[email protected])
Purpose: To evaluate the diagnostic performance of preoperative state-of-the-
art imaging of colorectal liver metastases (CRLM).
Methods
and Materials: Forty-six consecutive patients scheduled for
resection of suspected CRLM were evaluated prospectively over a 1.3-years
period (2011 to 2013). None of the patients had undergone previous treatment
for their CRLM. Dynamic 40-slice CT (unenhanced, arterial, portal-venous and
delayed-phase), low-dose FDG-PET/CT and liver-MRI with T2-weighted single-
shot, T1-weighted in- and opposed-phase, T2 weighted TSE-SPIR, diffusion-
weighted and dynamic Gd-EOB-DTPA (Primovist®) enhanced sequences were
used. Examinations were evaluated by two independent and blinded readers.
The reference standard (RS) was histopathological confirmation (77/135
CRLM) or a clinical assessment based on follow-up examinations (58/135
CRLM).
Results
RS confirmed 412 lesions including 135 CRLM. On a per lesion
basis, sensitivity was 70%, 90% and 63% for CT, MRI and FDG PET/CT,
respectively. The corresponding specificity was 94%, 87% and 99%. RS
confirmed CRLM in 42 patients and sensiti vity on a per patient basis was 93%,
100% and 98% for CT, MRI and PET/CT. For CRLM of less than 10 mm in size
sensitivity was 17%, 68% and 10% for CT, MRI and PET/CT, respectively.
Specificity was 96%, 89% and 98%, respectively.
Conclusion
MRI had higher sensitivity especially for CRLM of less than
10 mm in size but specificity was comparable to CT and FDG-PET.
Differentiation of hemangiomas and concurrent mucinous CRLM was
challenging on MRI. In cases of remaining uncertainty CT and FDG-PET/CT
can improve characterisation of liver lesion particular if above 10 mm in size.
B-0927 14:54
Normal values of liver and spleen stiffness measurements using shear
wave elastography (SWE)
P.S. Zoumpoulis; Kifissia/GR (
[email protected])
Purpose: /o determine the normal range of Liver Stiffness (LS) and Spleen
Stiffness (SS) measured by Shear Wave Elastography (SWE) and the cutoff
level between normal liver and CLD.
Methods
and Materials: 89 patients underwent US and Color Doppler of the
liver, the portal vein, the spleen and SWE of the liver and spleen. Normal group
(n=48) was defined as men and women 21 to 50 years old with body mass
index < 25 and without any clinical evidence of liver disease and normal
laboratory and ultrasonographic findings. Comparative groups were non-
cirrhotic chronic liver disease (NCCLD; n=16) and liver cirrhosis (LC; n=25)
groups with various CLD, including viral hepatitis and alcoholic LD.
Results
In the normal group, mean value of LS was 4.9 ± 1.7 kPa (95% CI,
4.6-6.6 kPa) and mean SD was 1.7 ± 0.5 kPa (95% CI, 1.5-1.7 kPa). In the
normal group the mean spleen stiffness (SS) was 10.4 ± 3.4 kPa (95% CI, 9.1-
10.4 kPa). In the NCCLD group mean LS were 9.4 ± 4.4 kPa (95% CI, 7.8-9.9
kPa) and 18.7 ± 8.9 kPa (95% CI, 15.9-21.7 kPa) in the LC group. SD were
2.35 ± 1.49 kPa (95% CI, 1.96-2.74 kPa) in NCCLD and 7.37 ± 7.06 kPa (95%
CI, 4.74-10.01 kPa) in LC.
S336
BA C D E F G
Monday
Conclusion
The range of Liver Stiffness in the normal group was 4.6 to 6.6
kPa and for Spleen Stiffness was 9.1 to 10.4 kPa. The LS considered as a cut-
off level differentiated from Chronic Liver Disease was 7.4 kPa.
B-0928 15:03
Potential dual energy volume scan implemented by 320-section area
detector CT (320-deADCT) through lower-dose acquisition imaging
protocol applied in liver tri-phase CT application: initial experience in
Taiwan
C.-H.C.K. Liang; Taipei/TW (
[email protected])
Purpose: The aim of the study was to decrease radiation dose utilised by 320-
deADCT scanner with DE imaging protocol for HCC follow-up cases without
compromising image quality and volume accuracy.
Methods
and Materials: 51 hepatocellular carcinoma (HCC) follow-up patients
implemented by liver tri-phase examination were collected in this study. The
first phase of 16 cm coverage liver exam was performed using conventional
helical scan with 120 kVp, tube current modulation and denoising iterative
reconstruction (IR) technology for non-contrast enhancement; whilst 16 cm
lower-dose DE volume scans with 135 kVp/80 kVp switch, mA adjustment and
IR technology were executed to catch arterial and venous phases. Both
qualitative and quantitative analyses were done and liver volume accuracy was
evaluated with liver phantom as well.
Results
With the 320-deADCT scanner, we can intensify contrast resolution in
the hypervascular HCC lesions. 110 kVp enhanced images were chosed for
quality optimisation in comparison with that of 120 kVp images. The qualitative
rating of 110 kVp images for arterial (venous) phases is 4.94; SNRs of 110 kVp
and 120 kVp images for quantitative analysis are 8.2 ±0.6 (7.8± 0.1), 15.0 ±2.5
(12.0±2.2), 30.7 ±4.0 (27.1 ±5.2), 12.2 ±1.1 (9.3± 1.3), 7.6 ±2.7 (6.9± 0.9), and -
19.3±4.7 (-18.0± 3.8) on liver parenchyma, liver lesion, aorta, spleen, muscle
and subcutaneous fat, respectively. Patients received 1.6mSv mean dose with
excellent volume accuracy (p < 0.05) acquired 34.7% radiation dose reduction
compared to that in general helical scan (2.5mSv mean dose).
Conclusion
320- deADCT scanner with lower-dose DE acquisition protocol
could generate excellent image quality without compromising diagnostic
purposes.
B-0929 15:12
Performance of integrated adaptive iterative dose reduction 3D into
automatic tube current modulation in radiation dose and image noise
reduction compared with filtered-back projection for 80-kVp liver CT:
anthropomorphic phantom and patient study
C.-M. Chen
1, M.-Y. Hsu1, Y.-L. Liao2, H.-Y. Tsai3; 1Taipei/TW, 2Hsinchu/TW,
3 Taoyuan/TW (
[email protected])
Purpose: Evaluate the radiation dose and image quality of adaptive iterative
dose reduction 3D (AIDR 3D) integrated into automatic tube current modulation
(ATCM) compared with filtered-back projection (FBP).
Methods
and Materials: Two part study consisting of anthropomorphic
phantom validation and prospective patient evaluation using the same
acquisition parameters. Sixty-three patients underwent 80-kVp non-contrast
liver CT with FBP and AIDR 3D acquisitions using the same standard deviation
of noise level. AIDR 3D images were reconstructed with 'strong' and 'standard'
settings. The mean attenuation, image noise , signal-to-noise (SNR) of the left
and right liver, aorta and psoas muscle were measured and compared. The
effective diameter (ED) at level of T12 was measured. The size-specific dose
estimate (SSDE) was calculated from console CTDIvol.
Results
Initial phantom study validated the radiation and image noise
reduction potential of AIDR 3D reconstruction. In patients, there was no
significant difference in mean attenuations between FBP and AIDR 3D
reconstructions. The mean SSDE for AIDR 3D and FBP acquisitions was 13.3
and 25.2 mGy, respectively. In patients with ED < 29 cm, there was a 55.3%
radiation dose reduction compared with FBP, whilst AIDR 3D 'strong' and
'standard' reconstructions showed a mean noise reduction of 28.5 and 16.2%,
respectively. The SNR was significantly higher in AIDR 3D and independent of
the patient's ED (p < 0.01).
Conclusion
Integration of AIDR 3D into ATCM allows for significant automatic
reductions in radiation dose and image noise compared with FBP. AIDR 3D
acquisitions allows for imaging of larger patient sizes with low-kilovoltage
acquisitions.
B-0930 15:21
Comparison between CT perfusion and indocyanine green retention test:
time to peak values can provide a non-invasive esteem of liver function
R. De Robertis, M. D'Onofrio, A. Ruzzenente, G. Puntel, S. Conci, S. Crosara,
S. Canestrini, A. Guglielmi, R. Pozzi-Mucelli; Verona/IT
(
[email protected])
Purpose: To evaluate the use of perfusion CT in the estimation of liver
function, comparing the perfusional data with the indocyanine green retention
test results and assessing their correlation with post-hepatectomy liver failure.
Methods
and Materials: 31 patients with hepato-biliary malignancies,
scheduled for liver resection, have been enrolled. A pre-operative perfusion CT
and the indocyanine green retention test were performed in the same day and
the results were compared using Pearson's correlation test. Perfusion
parameters were also compared with CT-measured future remnant liver
volume
Results
High correlation was found between the single arterial input time to
peak values and the ICGR15 and ICG-PDR values (R= 0.789 and -0.790,
respectively; p < 0.0001). The comparison between the time to peak values
obtained by pCT with single portal input analysis and the ICGR15 and ICG-
PDR values reported even higher correlation (R= 0.832 and - 0.823,
respectively; p < 0.0001). In cirrhotic patients arterial TTP, ICGR15 and
prothrombin Time are significantly higher compared with non-cirrhotic patients
(p=0.048). Higher levels of arterial TTP, ICGR15 and PT are significantly
related with signs of PHLF (p=0.004, 0.004 and 0.001, respectively). At
multivariate analysis arterial TTP, ICGR15 and FRLV are significantly related
with incidence of PHLF (HR 2.886, p value 0.024 and HR 0.034, p value 0.023,
respectively).
Conclusion
pCT may be an effective method to estimate liver function. Time
to peak values have shown high correlation with ICGR15 and ICG-PDR values.
Further studies are needed to validate these results.
14:00 - 15:30 Room C
Neuro
SS 1811a
Novel CT techniques
Moderators:
C. Hoffmann; Tel Hashomer/IL
E. Pravatà; Lugano/CH
B-0931 14:00
Ultra-low-dose Sinogram affirmed iterative reconstruction in head CT:
satisfactory for repeated surveillance exams in neurosurgical ICU
I. Corcuera Solano, L. Tanenbaum, A. Doshi; New York, NY/US
(
[email protected])
Purpose: To assess the image quality of ultra-low-dose (ULDCT) head CT
reconstructed with sinogram affirmed iterative reconstruction (SAFIRE) versus
low-dose (LDCT) SAFIRE and standard-dose (SDCT) examinations
reconstructed with filtered back projection (FBP), by evaluating examinations of
the same patient, and to compare its effect on radiation dose in a neurosurgical
intensive care unit (NSICU) population.
Methods
and Materials: A retrospective analysis of 60 head CT acquired
during 2012-2013 was performed. We compared ULDCT (n=28, avg CTDIvol
=15.55 mGy), LDCT (n=12, 36.46 mGy) and SDCT (n=20, 48.38 mGy). SDCT
exams were performed on a variety of clinical Siemens scanners using FBP
reconstruction technique. All LDCT and ULDCT exams utilised a commercially
available iterative reconstruction (IR) technique - SAFIRE at a setting of 3 on a
Siemens AS+ 128 scanner. These studies were evaluated for image quality,
noise and radiation dose.
Results
With ULDCT-SAFIRE, a 68% reduction of the CTDIvol of head CT
exams was seen compared to routine SDCT-FBP (79% below ACR
guidelines), while maintaining comparable quality and similar noise levels.
LDCT-SAFIRE offers a higher image quality compared to SDCT-FBP with no
differences in noise. When compared to LDCT, ULDCT had significantly higher
image noise and lower, yet still satisfactory, qualitative measures of image
quality.
Conclusion
ULDCT-SAFIRE allows a substantially lower dose, while
maintaining quality sufficient for repeated surveillance head studies of NSICU
patients. ULDCT-SAFIRE studies were satisfactory, comparing favourably to
SDCT-FBP. Implementation of SAFIRE for CT scans performed on NSICU
patients leads to a 68% reduction of radiation while maintaining image quality.
S337
BA C D E F G
Monday
B-0932 14:09
Knowledge-based iterative reconstruction technique allows for extreme
low dose for cerebral and carotid CT angiography studies
F. Zhang, L. Yang; Beijing/CN (
[email protected])
Purpose: To evaluate the potential of substantially reduced dose for cerebral
and carotid CT angiography studies by using a new knowledge-based iterative
reconstruction technique (IMR, Philips Healthcare) without any adverse impact
on accuracy.
Methods
and Materials: Cerebral and carotid CT angiography scans were
acquired using a 256-slice MSCT (Brilliance iCT, Philips Healthcare) on 60
patients with normal body mass index (BMI, 20-25 kg/m 2) who were randomly
assigned into 2 groups (group A and group B). The scan protocols for different
groups were drawn up as follows (table in uploaded image).The mean image
noise and CNR of different groups were measured on CT images and
compared using the paired-t test. In addition, image quality evaluation was
performed by two radiologists who were blinded to scan protocol, using a five-
point confidence scale (1 [poor] to 5 [excellent]).The results of the two groups
were compared with the Mann-Whitney U-test.
Results
There was no difference in mean image noise, CNR and image
quality between group A and B (p > 0.05). By using knowledge-based IMR
reconstruction technique, the low dose protocol for group B was feasible with
no significant loss in image quality or any negative effect on diagnosis
confidence. Compared to group A, group B reduced radiation dose by 71% and
the iodine volume by 27%.
Conclusion
Knowledge-based iterative reconstruction technique allows for
both low radiation and contrast medium doses for cerebral and carotid CT
angiography.
B-0933 14:18
Brain CT perfusion: effective dose reduction by using hybrid iterative
reconstruction and different low-dose protocols
A. Vishnevskaia, E. Kondratyev, N. Tarbaeva, G.G. Karmazanovsky;
Moscow/RU (
[email protected])
Purpose: To evaluate the effect of hybrid iterative reconstruction on qualitative
and quantitative parameters of low-dose 256-MDCT perfusion imaging.
Methods
and Materials: 30 consecutive patients were enrolled in the study.
CT perfusion in first group (n=10) was examined under 80 kv 150 mAs, second
group (n=10) - 80 kv 100 mAs, and 80 kv 50 mAs in third group. CT images in
first group were reconstructed only with the filtered back projection (FBP). CT
data in second and third groups were reconstructed both with FBP and three
levels of hybrid iterative reconstruction algorithms (iDose1, 3, 5). We compared
quantitative and qualitative parameters of images among the three groups.
Quantitative blood flow perfusion parameters were compared between four
reconstructions in second and in third groups.
Results
Effective dose was 4.7 ±0.07mSv in first group, 3.08 ±0.07mSv in
second group and 1.5 ±0.07mSv in third group; differences were significant
(p < 0.05). Image noise using FBP was 3.1 ±0.49 in first group, 4.64 ±0.6 in
second group and 7.1± 0.88 (p < 0.05) in third group. Overall CT perfusion
maps quality decreased using second and third low-dose protocols in
combination with FBP. The quality of images increased significantly (p < 0.05)
when applying hybrid iterative reconstruction. In all studies there was no
significant difference in selected quantitative parameters between acquired
data after FBP and iDose1, 3, 5 reconstructions (p > 0.05).
Conclusion
Low-dose CT perfusion using hybrid iterative reconstruction may
provide sufficient image quality and allows for significant reduction of radiation
dose to the patient.
B-0934 14:27
Iterative reconstruction: Improvement of image quality for dynamic CT
brain perfusion imaging
H. Einhellig, H. Poppert, E.J. Rummeny, A. Huber;
Munich/DE (
[email protected])
Purpose: Impact quantification of iterative reconstruction (iDose) on image
noise, SNR and CNR of brain matter and investigation of radiation dose
savings by evaluation of stability of rCBV in iMTT.
Methods
and Materials: CTP was obtained in 27 patients using a 256- slice
CT. Images were reconstructed with filtered backprojection (FBP) and five
different levels of IR (LD 1- LD 5). Noise, CNR (cortex vs. white matter), SNR
and rCBV in iMTT were determined.
Results
Noise was reduced from 5.7 ± 0.1 (FBP) to 3.8 ± 0.2 (LD 5) for grey
cortex and from 6.4 ± 0.0 (FBP) to 4.0 ± 0.1 (LD 5) for white matter. SNR
improved from 6.7 ± 3.3 (FBP) to 10.3 ± 0.6 (LD 5) for grey cortex as well as
for white matter from 4.0 ± 12.3 (FBP) to 6.5 ± 3.3 (LD 5). CNR increased from
2.2 ± 0.1 (FBP) to 3.5 ± 0.1 (LD 5) for grey matter vs. white matter. The
parameter rCBV in iMTT were varying only slightly with a mean rCBV 4.1 ± 0.1
and a mean relation rCBV/nCBV 0.27 ± 0.02 for all IR- levels.
Conclusion
Iterative recontruction can improve SNR and CNR by noise
reduction of about 33%. Iterative reconstruction may save radiation dose in
brain perfusion imaging. Moreover, the use of different IR-levels of iDose (LD
1-5) does not effect the CT brain perfusion parameters rCBV and MTT as two
distinct PCT parameters which differ the penumbra and the infarct core in the
summary maps.
B-0935 14:36
Head CT: adaptive statistical iterative reconstruction protocol- the same
image quality and lower radiation dose comparing to filtered back
projection (FBP) protocol
M. Guziski, L. Waszczuk, A. Czarnecka, T. Kra !nicki, M. Ssiadek;
Wroclaw/PL (
[email protected])
Purpose: To compare dose radiation and image quality (SNR, CNR) of head
CT examinations of the same patients obtained with different protocols:
Adaptive Statistical Iterative Reconstruction (ASIR) and Filtered Back
Projection (FBP) using two 64 MDCT scanners.
Methods
and Materials: Head CT studies of 55 consecutive patients (29
females/26 males, mean age 60 yrs) were examined twice for medical
indications (trauma), using two different 64 MDCT scanners. Initial examination
was performed using FBP reconstruction. In the follow-up examination of the
same patient ASIR protocol was used. Scan parameters were held constant
regarding tube voltage (120 kV), sequential scanning (2.5 mm/5 mm). ASIR
was performed at 40% level. CT dose index volume (CTDvol) were recorded
and compared. Two blind radiologists reviewed all CT examinations assessing
image noise (SNR), contrast (CNR) and diagnostic acceptability.
Results
Comparison of head CT using FBP and ASIR scanners showed very
significant differences (p < 0.001) in average effective dose (1.72 ±0.07 and
1.38±0.12 [mSv], respectively). There was no significant difference in image
quality between two types of reconstructions. SNR for white matter was 7.3 for
FBP and 8.7 for ASIR (P=0.1) and for grey matter 9.7 vs. 11.6 (p=0.6)
respectively. Contrast between white and grey matter was 0.8 and 1.2 (p=0.1),
respectively. The overall diagnostic score was 2.6 vs. 2.7 (in 3-point scale).
Conclusion
Head CT using ASIR protocol effectively reduces exposure
dosage by about 25% without sacrifying image quality. Contrast between white
and grey matter is on the equal level in FBP and ASIR group.
B-0936 14:45
A reduced contrast volume acquisition regimen based on cardiovascular
dynamics reduces radiation dose during carotid MDCT angiography
C. Saade, M. Hourani; Beirut/LB (
[email protected])
Purpose: To investigate the dose length product (DLP) during carotid
computed tomography angiography (CCTA) using a patient-specific contrast
formula.
Methods
and Materials: CCTA was performed in 202 patients with stroke like
symptoms using a 64-channel computed tomography scanner and a dual-
barrel contrast injector. Patients were subjected in equal numbers to one of two
acquisition/contrast regimens. Patient age an d gender were equally distributed
across both groups. Regimen A, the department's standard protocol, consisted
of a caudocranial scan direction with 100 mL of contrast, intravenously injected
at a flow rate of 4.5 mL/s; Regimen B, involved a craniocaudal scan direction
and a novel contrast formula based on patient cardiovascular dynamics. Each
scan acquisition comprised of 120 kVp, 300 mA with modulation, temporal
resolution 0.4 sec and pitch 0.981:1. The DLP was measured between each
regimen and data generated were compared using Mann-Whitney U non-
parametric statistics.
Results
The mean contrast volume was significantly lower in regimen B
(53 ± 10 mL) compared to A (100 ± 1 mL) (p < 0.001). There was no significant
difference in mean scan time in regimen B (4.22 ± 1.2 sec) compared to A
(4.01 ± 1.3 sec) with equal distribution in scan range between each regimen (A:
29.2 + 3.01 cm and B: 28.9 + 4.03 cm). Mean DLP demonstrated significant
reduction in regimen B (3.09+0.22 mSv) compared to A (4.74+0.22 mSv)(p =
0.02).
Conclusion
Significant reduction in radiation dose during CCTA can be
achieved using low contrast volume based on patient specific contrast formula.
B-0937 14:54
Patient-specific contrast protocol based on cardiovascular dynamics
reduces radiation dose during intra-cranial MDCT angiography
C. Saade, M. Hourani; Beirut/LB (
[email protected])
Purpose: To investigate the dose length product (DLP) during intra-cranial
computed tomography angiography (ICTA) using a patient-specific contrast
formula.
Methods
and Materials: ICTA was performed in 80 patients with stroke-like
symptoms using a 64-channel computed tomography scanner. Patients were
subjected in equal numbers to one of two contrast regimens. Regimen A, the
department's standard protocol, consisted of a craniocaudal scan direction with
S338
BA C D E F G
Monday
80 mL of contrast, intravenously injected at a flow rate of 4.5 mL/s; Regimen B,
involved a novel contrast formula based on patient cardiovascular dynamics.
Each scan acquisition comprised of 120 kVp, 300 mA with modulation,
temporal resolution 0.4 seconds and pitch 0.981:1. The DLP was measured
between each regimen and data generated were compared using Mann-
Whitney U non-parametric statistics.
Results
Mean vessel attenuation in the segments of the circle of Willis was up
to 39% (p < 0.02) greater in regimen B compared to A. In the venous system,
attenuation was significantly lower in regimen B compared to A with a
maximum reduction of up to 86% (p < 0.001). The mean contrast volume was
significantly lower in regimen B (53 ±10 mL) compared to A
(80±1 mL)(p < 0.001). There was no significant difference in mean scan time in
regimen B (4.22 ±1.2 sec) compared to A (4.01 ±1.3 sec) with equal distribution
in scan range between each regimen (A: 29.2 ±3.01 cm and B: 28.9 ±4.03 cm).
Mean DLP demonstrated significant reduction in regimen B (3.99 ±0.22 mSv)
compared to A (4.74±0.22 mSv) (p = 0.02).
Conclusion
Significant reduction in radiation dose during ICTA can be
achieved using low-contrast volume based on patient-specific contrast formula.
B-0938 15:03
Both contrast medium dose and injection rate reduction in carotid-
cerebral angiography with 256-slice MSCT: feasibility study of a new
injection protocol for improving patient safety
F. Zhang, L. Yang; Beijing/CN (
[email protected])
Purpose: To evaluate the potential of substantially reduce dose for cerebral
and carotid CT angiography studies by using a new low-dose protocol without
any adverse impact on accuracy.
Methods
and Materials: CT carotid-cerebral angiography scans were
acquired using a 256-slice MSCT (Brilliance iCT, Philips Healthcare) for 60
atherosclerosis suspected patients with normal BMI (20-25 kg/m2) who were
randomly assigned into 2 groups (30 patients each). Patients in group A
received 60 ml iodine contrast medium (370 mgI/ml) with an injection rate of
4.5 ml/s by using bolus tracking, while patients of group B received 30 ml
contrast medium (370 mgI/ml) with an injection rate of 3.0 ml/s also by using
bolus tracking. The scan protocol for both groups was 120 kV, 250 mAs and all
images were reconstructed using an IR technique (iDose4, Philips Healthcare).
Mean carotid-cerebral arterial CT numbers and CNRs of two groups were
measured. In addition, each group was blindly evaluated by two radiologists for
image quality (rated on a 5-points confidence scale (1 [poor] to 5
[excellent]).Statistical analysis was performed using paired-t test.
Results
Compared to group A, group B reduced the iodine delivery rate by
33.5% from 1.67 gI/s to 1.11 gI/s and the total iodine volume by 50% from
22.2 gI to 11.1 gI. There was no significant difference in mean carotid-cerebral
arterial CT numbers, CNRs and image quality between two groups (p > 0.05)).
Conclusion
By using 256-slice MSCT and an iterative reconstruction
technique, a low-iodine contrast protocol for carotid-cerebral CTA can reduce
both contrast medium dose and injection rate without any negative impact on
accuracy.
B-0939 15:12
Co-registration of transcranial ultrasound and CT-angiography: a
methodological study in cerebrovascular disease
A. Nygård, S. Rosenbaum, J. Nielsen, C. Ovesen, A. Christensen,
H. Christensen; Copenhagen/DK (
[email protected])
Purpose: Multimodal imaging is used increasingly in acute cerebrovascular
disease. A previously obtained CT dataset can guide a real time transcranial
duplex (TCD) dataset if a mutual focus point determines interpretation of
movement directions represented by scrolling on CT and corresponding
angulation of the transducer, i.e. identifying the same middle cerebral artery
branch. Aim was to evaluate a fast bedside method using a CT dataset as
guide for serial monitoring of acute stroke patients with transcranial duplex.
Methods
and Materials: The temporal window centre was chosen as focus
point on TDC and subsequently transcribed to the CT modality. Local bone
density and thickness vary and the possibility of repeated identification the
identical focus point equals the degree of measurement variation. Bilateral
measurements were obtained in 10 patients 3 times each on 3 different non-
contrast cerebral CTs (one observer). A phantom applicable to both computed
tomography and ultrasound was used to test for software and intermodality
induced size distortion. The phantom underwent CT-scan equipped with a
casement fixating an ultrasound transducer in one location, which was used
during the subsequent ultrasound performed during real-time fusion on a Logic
E9 GE ultrasound apparatus. Using distance measurements from the surface
to 5 predefined fix points; variation was considered insignificant below 3 mm.
Results
Measurement between modalities did not reach or exceed the
defined level of significance. Repeated measurements of focus point showed
no significant variation.
Conclusion
We present a novel technique for monitoring patients in the
unstable phase of acute stroke.
B-0940 15:21
One-step stroke imaging: does an interleaved acquisition of cerebral CT
perfusion and CTA of the carotids affect CTP values?
M.T.H. Oei, R. Manniesing, F.J.A. Meijer, M. Prokop; Nijmegen/NL
(
[email protected])
Purpose: One-step stroke imaging is a CT perfusion (CTP) scan in which one
volumetric acquisition is replaced to acquire a carotid CTA using toggling table
technique and a single dose of contrast agent. The purpose of this study is to
determine if missing one acquisition of the CTP influences the CTP values.
Methods
and Materials: Ten patients with suspicion of ischemic stroke were
scanned with a clinical CTP head protocol (14 scans every 2s, 5 scans every
5s) with a total duration of 55s using a 320-row CT scanner. The one-step
stroke protocol is simulated from the original clinical protocol by deleting one
acquisition. For every patient, the timepoint of the bolus arrival time (BAT) and
the arterial peak (AP) in the middle cerebral artery was determined. One
acquisition was deleted starting from the BAT up to the fifth time point after AP.
Corresponding perfusion maps were calculated with bSVD using PMA-ASIST.
Regions of interests (ROIs) were annotated in normal-appearing grey and
white matter. The percentage errors were calculated per timepoint and patient.
Results
The absolute mean of the percentage errors across all patients for
each timepoint in grey matter compared to the original CBF, CBV and MTT is
3.40%(range 0.10-9.53%), 3.22%(0.00-9.98%) and 3.08%(0.00-13.79%),
respectively. Percentage errors > 8.50% occurred for some patients if an
acquisition was deleted at BAT, 2s-4s after BAT, AP or after the AP. Similar
Results
were found in WM.
Conclusion
A one-step stroke protocol is feasible with only minor effects on
the CTP maps if CTA is acquired 2-4s after BAT and before the AP.
Author Disclosures:
R. Manniesing: Grant Recipient; Toshiba Medical Systems Corporation,
Japan. M. Prokop: Grant Recipient; Toshiba Medical Systems Corporation,
Japan, Philips Medical Systems. Speaker; Bracco, Toshiba Medical Systems
Corporation, Bayer-Schering, CME Science, Philips Medical Systems.
14:00 - 15:30 Room D
Chest
SS 1804
Lung structure and function
Moderators:
P.A. Grenier; Paris/FR
N. Sverzellati; Parma/IT
B-0941 14:00
Size and collapsibility of emphysema holes on CT of COPD: evaluation
with a new method
S.Y. Oh, J.B. Seo, S. Lee, N. Kim, M. Lee; Seoul/KR (
[email protected])
Purpose: Although the extent of LAA at CT of COPD is known to correlate with
loss of lung function, the size and collapsibility of emphysema holes were
rarely investigated. The purpose of this study is to assess the size and
collapsibility of emphysema clusters with a new method and to correlate it with
pulmonary functional test (PFT).
Methods
and Materials: Volumetric, inspiration and expiratory CT scans in 60
COPD patients were selected. After extracting the area of LAA using the
threshold of -950 HU, a new method of size classification of LAA, which is
repeated application of multiple low-pass filter with various size of Gaussian
kernel, was used. Emphysema clusters were divided into four groups;
E1< 1.5 mm, 1.5 mm E2< 7 mm, 7 mm E3< 15 mm, 15 mm E4. The
difference in distribution of each group between inspiration and expiration CT
was assessed. The results were compared with PFT with Pearson correlation.
Results
The mean extents of LAA, E1, E2, E3, and E4 were 27.2%, 3.9%,
6.8%, 12.9%, 3.5% on inspiration CT, 16.5%, 1.66%, 7.8%, 4.2%, 2.9% on
expiratory CT, respectively. Among the four clusters, E3 showed larger decline
on expiratory CT than other clusters. Both E2 and E3 were significantly
correlated with FEV1 (r=-0.449 and -0.423, respectively).
Conclusion
Emphysema clusters of sublobular size were most collapsible.
Emphysema of acinar and sublobular size contribute most to the FEV1 decline.
This study shows that in addition to the extent of LAA, the size of emphysema
clusters at CT of COPD should be also considered in relation to the loss of
lung function.
S339
BA C D E F G
Monday
B-0942 14:09
CT-quantified airway wall thickness and emphysema: association with
lung function decline and development of airflow limitation
F.A.A. Mohamed Hoesein1, M. Schmidt2, B. van Ginneken3, J.-W.J. Lammers1,
H.J. de Koning4, M. Oudkerk5, D.S. Postma5, P.A. de Jong1; 1Utrecht/NL,
2Bremen/DE, 3Nijmegen/NL, 4Rotterdam/NL, 5Groningen/NL
(
[email protected])
Purpose: Structural pulmonary changes like airway wall thickness and
emphysema contribute to airflow limitation. It is unknown whether emphysema
and airway wall thickness quantified on computed tomography (CT)
independently associate with lung function decline and development of airflow
limitation.
Methods
and Materials: Male former and current smokers without and with
airflow limitation participating in a lung cancer screening study were included
and underwent baseline and follow-up spirometry and chest CT scanning.
Airway wall thickness and emphysema were quantified automatically and
expressed as the square root of wall area for a theoretical airway with 10 mm
lumen perimeter (Pi10) and the 15
th percentile method (Perc15), respectively.
Results
2,021 subjects were included. Median (interquartile range) of
follow-up was 3.0 (2.9-3.1) years. At univariate analyses Pi10 and Perc15
correlated with baseline FEV1, r=-0.49 and 0.11, respectively (p < 0.001).
Multiple linear regression analysis showed that Pi10 and Perc15 were
independently associated with a lower FEV1 after follow-up (p < 0.05). For
each standard deviation increase in Pi10 and standard deviation decrease in
Perc15, FEV1 decreased with additional 20 mL and 30.2 mL, respectively. The
adjusted odds ratio's for developing airflow limitation were 1.26 and 2.44,
respectively.
Conclusion
A greater degree of airway wall thickness and emphysema on CT
independently associate with a lower FEV1 and with development of airflow
Limitation
after three-year of follow-up.
B-0943 14:18
Comparative assessment of T1 imaging, oxygen-enhanced MRI and first-
pass perfusion MRI in chronic obstructive pulmonary disease at 1.5 Tesla
B.J. Jobst, S. Triphan, O. Sedlaczek, A. Anjorin, H.-U. Kauczor, J. Biederer,
S. Ley, J. Ley-Zaporozhan, M.O. Wielpütz; Heidelberg/DE
Purpose: COPD phenotype and severity are insufficiently assessed by lung
function testing alone. Therefore, alternative endpoints for interventional trials
are pivotal. Lung T1 is known to depend on lung tissue and blood volume. It
was the aim of this study to validate MRI-based T1 mapping and oxygen-
enhanced MRI (OE-MRI) against first-pass perfusion MRI in COPD patients
applying a user-friendly standardised assessment method.
Methods
and Materials: 20 COPD patients (GOLD I-IV) underwent MRI,
comprising of a coronal 2-dimensio nal inversion recovery snapshot flash
sequence (8 slices/lung) at room-air and after supplementing pure oxygen, as
well as first-pass contrast-enhanced perfusion imaging with high-temporal
resolution (1.5s/lung) at roomair. The spatial extent of T1 shortening at roomair
(,T1RA), reduction of oxygen-induced T1 shortening ( ,T1O2) and perfusion
deficits of the upper, middle and lower zone of both lungs was reported by 2
chest radiologists in consensus, using a semi-quantitative 3-point scale for
each item.
Results
In a zone-based approach ,T1RA correlated positively with the
extent of perfusion deficits (r=0.81; p < 0.001). ,T1O2 also correlated
positively with perfusi on deficits (r=0.80; p < 0.001) and ,T1RA (r=0.80;
p < 0.001). Interestingly, in mild COPD ,T1O2 was normal in 16/39 lung zones
with perfusion deficits. In a per-patient approach perfusion deficits (r=0.52;
p < 0.05), ,T1RA (r=0.45; p < 0.05), and ,T1O2 (r=0.52; p < 0.05) positively
correlated with GOLD stage.
Conclusion
T1 mapping and OE-MRI demonstrated a good agreement with
perfusion MRI and GOLD stage and provide complementary information about
pathologic changes in COPD. In particular, OE-MRI contributes to the
differentiation of hypoxic vasoconstriction and genuine perfusion impairment.
B-0944 14:27
Anatomical detail of single breath-hold, high resolution ultra-fast 3D
balanced SSFP MRI of the chest in comparison to low-dose CT
T. Heye, G. Sommer, J. Bremerich, O. Bieri; Basle/CH (
[email protected])
Purpose: To evaluate anatomical detail and image quality of a novel three-
dimensional balanced steady state free precession (bSSFP) MRI sequence in
comparison to low-dose CT.
Methods
and Materials: In this IRB approved study 16 male patients (mean
age 64 yrs). underwent same day chest imaging on a 1.5 T MRI (Avanto,
Siemens Healthcare) and a 64-slice MDCT scanner (Definition Flash, Siemens
Healthcare). MR acquisition was performed in a single breathhold ( < 25sec)
with 1.8 mm isotropic spatial resolution. Depiction of detail by ultra-fast bSSFP
was evaluated by two experienced readers independently who assessed the
number of branching points for 6 pre-defined pulmonary arteries. The distance
between the most peripheral visible segments to the pleural surface was
measured for each vessel and at 6 locations on 50 mm coronal maximum
intensity projections (MIP). Image quality and sharpness was rated on a 5-point
scale (5=best score). Similar measurements on CT data served as reference
standard.
Results
Ultra-fast bSSFP identified 72.0% of branching points detected by CT
(1077/1496). The mean distance, distal segments to pleura, on thin slices was
13.3 ± 4.3 mm versus 9.0 ± 3.3 mm (ultra-fast bSSFP versus CT; p < 0.001 t-
test) and 8.9 ± 4.1 mm versus 4.8 ± 2.7 mm respectively on MIP
reconstructions (p < 0.001 t-test). Mean image quality and sharpness were
each rated as 4 (range 3-5).
Conclusion
Ultra-fast SSFP of the chest offers high resolution imaging in a
single breath-hold with adequate image quality and sharpness allowing for
visualisation of anatomical details comprising peripheral pulmonary vessels
less than 15 mm to the pleural surface.
B-0945 14:36
Regional obstruction in cystic fibrosis: correlation of electric impedance
tomography (EIT) and high-resolution-CT (HRCT) findings
U.G. Mueller-Lisse1, Z. Zhao1, I. Frerichs2, R. Fischer1, M.F. Reiser1,
K. Moeller3; 1Munich/DE, 2Kiel/DE,
3Villingen-Schwenningen/DE (
[email protected])
Purpose: Electric impedance tomography (EIT) provides both global and
regional information on airway obstruction in patients with cystic fibrosis (CF).
We correlated obstruction in CF patients as measured by EIT with high-
resolution-computed-tomography (HRCT) findings based on the Brody-scoring
system.
Methods
and Materials: HRCT images (120 KVp, 35 mA, 64x0.5 mm,
reformatting slice thickness, 1.0-1.5 mm and 3 mm, Brilliance CT64, Philips-
Medical-Systems, Hamburg, Germany) of 5 selected CF patients (2 male, 3
female; age 38± 11 years; height 165 ±8 cm; weight 56 ±8 kg; mean ±SD)
covering EIT-electrode positions ±5 cm were evaluated by means of a weighted
Brody-score, which considers bronchiectasis, mucous plugging, peribronchial
thickening, parenchymal opacity and hy perinflation. Two-dimensional EIT
measurements were performed at the level of the fifth intercostal space (EIT
Evaluation KIT 2, Dräger Medical, Lübeck, Germany) on the same patients
within 2 months of HRCT, during standard pulmonary function tests as
recommended by the American-Thoracic-Society and European-Respiratory-
Society guidelines. Ratios of maximum-expiratory-flow at 25% and 75% of vital
capacity ( MEF
25/MEF75) were calculated for different lung regions in EIT
images. After normality testing (Lilliefors test), linear regression (significance
level, p < 0.05) was performed to assess the correlation between MEF25/MEF75
values and weighted Brody-scores.
Results
Regional airway obstruction identified in MEF25/MEF75 maps matched
HRCT findings. Median values of MEF25/MEF75 and weighted Brody-Score
were highly correlated (r2=0.83, P < 0.05).
Conclusion
In CF patients, severity of regional airway obstruction, as
measured by means of EIT, correlates with severity of morphologic lung
lesions, as measured in HRCT images by means of weighted Brody scores.
B-0946 14:45
Krypton ventilation imaging with dual-energy CT: correlation with
pulmonary function tests in patients with chronic obstructive pulmonary
disease (COPD)
F. Molinari, S. Badr, N. Tacelli, J.-B. Faivre, B. Wallaert, M. Remy-Jardin;
Lille/FR (
[email protected])
Purpose: To correlate krypton ventilation CT with pulmonary function tests
(PFT) in COPD patients.
Methods
and Materials: 31 patients underwent dual-source, dual-energy
chest CT after inhalation of a mixture of 80% krypton and 20% oxygen, with
reconstruction of morphologic and krypto n-ventilation images with calculation
of: (a) the total lung volume enhanced by krypton; and (b) the mean density of
voxels with krypton. All patients were assessed with routine PFTs, including
measurements of bronchial obstruction (FEV1; FVC; FEV1/FVC ratio), lung
distension (RV; FRC; TLC), and destruction (DLco).
Results
Correlations were found between: (a) pulmonary volume enhanced
by krypton (6161 ±1385 mL) and indexes of lung distension (TLC: r=0.78,
p < 0.0001; FRC: r=0.57, p < 0.01); and (b) mean density of krypton
(7.5±2.3 HU) and indexes of bronchial obstruction (FEV1: r=0.71, p < 0.0001;
FVC: r=0.66, p < 0.0001; FEV1/FVC: r=0.54, p < 0.01) and lung destruction
(DLco: r=0.62, p < 0.01). The difference in TLC, measured by body
plethysmography versus the helium dilution method, inversely correlated with
the mean density of krypton on ventilation maps (r=-0.55, p=0.0029). The
mean density of krypton within voxels on the krypton-ventilation maps
decreased from GOLD stage 1 to GOLD stage 4 (GOLD 1: 9.4 ±1.8 HU, GOLD
2: 8.1±0.5, GOLD 3: 7.6 ±2.4, GOLD 4: 5.8± 1.6) and was significantly different
between GOLD stages 1 and 2 (n=11) vs. GOLD stages 3 and 4 (n=17)
(8.2±2.3 HU vs. 6.3±1.7 HU; p=0.016).
S340
BA C D E F G
Monday
Conclusion
Krypton ventilation imaging on dual-energy CT correlates with
functional parameters of bronchial obstruction, lung distention, and destruction,
and provides significantly different results according to the GOLD stages.
B-0947 14:54
Value of density mapping in computed tomography for detection of
bronchiolitis obliterans syndrome (BOS)
S. Dettmer, O. Solyanik, T. Kaireit, C. de Wall, F. Wacker, H.-o. Shin;
Hannover/DE (
[email protected])
Purpose: To prospectively evaluate the diagnostic value of density mapping
for detection of bronchiolitis obliterans syndrome (BOS) following lung
transplantation.
Methods
and Materials: 386 CT examinations were performed in lung
transplant patients in inspiration/expiration (64 row MDCT, 120 kVp, rotation
time 0.8s, pitch 0.984, collimation 1.25 mm, reconstruction increment 1 mm).
44/342 examinations were performed in patients with/without BOS. Following
automatic lung segmentation and non-rigid registration of inspiration to
expiration, a point-to-point mapping of the HU values in inspiration and
expiration was performed. A scatter plot was used to depict the frequency
distribution of the point-to-point mapping (density mapping). This was
characterised by the following location scales: the x value and y value of the
median, the distances of the median to the origin/bisecting line and the first
principal component (PCA).
Results
Scatter plots of HU values of the re gistered inspiration and expiration
showed significant differences in patients with/without BOS. A shift to lower
density values and a convergence to the bisecting line could be observed in
patients with developing BOS. Evaluated measures of the frequency
distribution in the density mappings we re significantly different in patients
with/without BOS for the y value of the median (p < 0.001, mean: -768 HU/-
712 HU), the distance of the median to the origin (p < 0.001), the distance of
the median to the bisecting line (p < 0.001) and PCA (p=0.030). The x value of
the median (p=0.859) was not significant.
Conclusion
Density mappings were significantly different in patients
with/without BOS and might be used as an imaging biomarker for the detection
of BOS.
B-0948 15:03
Voxel-to-voxel analysis of inspiration-expiration CT datasets for detection
of pathologic air trapping in lung transplant patients: comparison to the
threshold-based method in expiration
O. Solyanik
1, S. Dettmer2, T. Kaireit2, C. de Wall2, F. Wacker2, H.-o. Shin2;
1Moscow/RU, 2Hanover/DE
Purpose: To determine whether voxel-to-voxel analysis of inspiration-
expiration CT datasets is more precise in detection of pathologic air trapping
(pAT) in lung transplantat patients than the threshold-based method in
expiration.
Methods
and Materials: 144 lung transplant recipients underwent paired
inspiratory-expiratory CT and PFTs six months after lung transplantation. Two
Methods
based on voxel-to-voxel mapping of inspiration-expiration CT
datasets (density mapping (DM) and parametric response map (PRM)) were
compared to the threshold-based method in expiration (EXP). Attenuation
ranges for EXP and DM were optimised by systematic variation and correlation
with the ratio of residual volume to total lung capacity (RV/TLC) by Spearman
rank correlation tests. For PRM published data was used. Correlations of CT
Methods
with RV/TLC were evaluated by Spearman rank correlation test. AT
was considered pathologic if RV/TLC was beyond the 95
th percentile of the
predicted values. The detection of pAT was assessed by comparing the areas
under the receiver operating characteristic curves (AUC) of quantitative CT
measures.
Results
According to RV/TLC pAT was present in 34 patients. DM and PRM
correlated significantly better with RV/TLC than Exp
-790 to -950 HU (DM r =0.66,
PRM r=0.65 EXP r=0.52; p < 0.01). AUC of PRM and DM were significantly
larger than by EXP (PRM: AUC 0.79, 95 % CI 0.704-0.876; DM: 0.78, 95% CI
0.691-0.865; Exp -790 to -950 HU: 0.708, 95% CI 0.608-0.808).
Conclusion
DM and PRM showed better correlation with RV/TLC than the
threshold-based method and were more precise in detection of pAT in lung
transplantat patients.
B-0949 15:12
Early cystic fibrosis lung disease: monitoring changes in structure and
perfusion and response to therapy with MRI
M.O. Wielpütz, M. Puderbach, A. Kopp-Schneider, M. Stahl, E. Fritzsching,
J. Biederer, H.-U. Kauczor, M. Eichinger, M.A. Mall;
Heidelberg/DE (
[email protected])
Purpose: Recent studies demonstrating early structural lung damage in infants
and preschool children with cystic fibrosis (CF) suggest that non-invasive
monitoring will be important to identify patients who may benefit from early
therapeutic intervention. For older CF patients, previous studies demonstrated
that magnetic resonance imaging (MRI) detects structural and functional
abnormalities in the lungs without radiation exposure. Therefore, our aim was
to evaluate the potential of MRI to detect abnormal lung structure and
perfusion in infants and young children with CF, and to monitor response to
therapy for pulmonary exacerbation.
Methods
and Materials: MRI studies were performed in 50 children with CF
(age 3.1± 2.1years, range 0-6years) in stable clinical condition (n=40) or
pulmonary exacerbation before and after antibiotic treatment (n=10), and in 14
non-CF controls (age 2.1 ±1.8years). T1-weighted sequences before and after
intravenous contrast, T2-weighted sequences and first-pass perfusion imaging
were acquired, and assessed using a dedicated morpho-functional score.
Results
MRI demonstrated bronchial wall-thickening/bronchiectasis, mucus
plugging and perfusion deficits from the first year of life in most stable CF
patients (global score 10.0± 4.0), but not in non-CF controls (score 0.0 ±0.0;
P < 0.001). In patients with exacerbations, the global score was significantly
increased to 18.0 ±2.0 (P < 0.001), and was restored to 12.0 ±3.0 (P < 0.05)
after antibiotic therapy.
Conclusion
MRI detected abnormalities in lung structure and perfusion, and
response to therapy for exacerbations in infants and preschool children with
CF. These results support the development of MRI for non-invasive monitoring
and as an endpoint in interventional trials for early CF lung disease.
B-0950 15:21
Is bronchial imaging affected by temporal resolution? Comparative
evaluation at 140 and 75 ms in 90 patients
N. Tacelli, A. Hutt, T. Santangelo, C.-F. Murphy, M. Remy-Jardin, J. Remy;
Lille/FR (
[email protected])
Purpose: To evaluate the influence of temporal resolution (TR) on cardiac
motion artifacts at the level of bronchial walls.
Methods
and Materials: 90 patients (mean age: 50.2 yr, mean heart rate:
81.2 bpm) underwent a noncontrast CT examination with dual-source, single-
energy (collimation: 32x2x0.6 mm; rotation time: 0.28 s). Two series of images
were reconstructed using data from both tubes on a prototype workstation with
a TR of 75 ms (i.e., optimised TR) (Group 1) and 140 ms (i.e., standard TR)
(Group 2). Two radiologists independently analysed the presence and severity
of cardiogenic artifacts at the level of 8 target bronchi (total number of bronchi
examined: n=720).
Results
Cardiogenic artifacts were significantly less frequent and less severe
in Group 1 than in Group 2 (p < 0.0001) with the highest scores of discordant
ratings for bronchi in close contact wi th cardiac cavities: RB5 (61/90; 68%);
LB5 (66/90; 73%); LB7 (63/90; 70%) (p < 0.0001). In Group 1, 78% (560/720)
of bronchi showed no cardiac motion artifacts whereas 22% of bronchi
(160/720) showed artifacts, rated as mild (152/160; 95%), moderate (7/160;
4%) and marked (1/160; 1%). In Group 2, 30% of bronchi (217/720) showed no
cardiac motion artifacts whereas 70% of bronchi (503/720) showed artifacts,
rated as mild (410/503; 82%), moderate (82/503; 16%) and severe (11/503;
2%). Intraobserver agreement for cardiac motion assessment was excellent
(reader 1: kappa=0.85 [95CI: 0.73-0.96]; reader 2: kappa=0.88 [95CI: 0.76-
0.99]); the interobserver agreement was good (kappa=0.61 [95IC: 0.43-0.80]).
Conclusion
At 75 ms, most bronchi can be depicted without cardiogenic
artifacts.
14:00 - 15:30 Board Room B
Paediatric
SS 1812
Radiation reduction in paediatric imaging
Moderators:
R.A.J. Nievelstein; Utrecht/NL
S. Stafrace; Aberdeen/UK
B-0951 14:00
-H2 AX foci as effect biomarker for CT radiation exposure in paediatric
patients: an individualised approach to estimate radiation risks
C. Vandevoorde1, C. Franck1, K. Bacher1, C. Ernst2, L. Breysem3, P. Smeets1,
K. Van De Moortele4, A. De Backer1, H. Thierens1; 1Ghent/BE, 2Brussels/BE,
3Leuven/BE, 4Bruges/BE (
[email protected])
Purpose: To evaluate biological effects and estimate cancer risks from
paediatric CT, the 3-H2 AX foci assay was used as biomarker for radiation-
induced double strand breaks in combination with patient-specific Monte Carlo
dose simulation.
Methods
and Materials: 51 paediatric patients (mean age, 4.5 years) were
included. Patients underwent CT abdomen (10) or CT chest (41) in five Belgian
radiology departments using state-of-the-art CT instrumentation and protocols.
Blood samples were taken before and after the CT procedure and 3-H2 AX foci
S341
BA C D E F G
Monday
were determined in peripheral blood T-lymphocytes. Patient-specific organ and
tissue doses were calculated using ImpactMC 1.3.1 Monte Carlo software.
Blood doses were calculated as a weighted sum of doses to lungs, heart, liver
and remainder. Patient individualised esti mations of lifetime attributable risks
(LAR) for cancer mortality were determined according to the BEIR VII risk
models.
Results
An average increase of 0.173 foci/cell was observed, despite the low
CT doses (mean DLP chest 35.2 mGycm). Differences in observed 3 -H2 AX
foci scores reflected the differences in dose levels between radiology centers.
Plotting the induced 3-H2 AX foci data versus the calculated blood doses,
indicated a low-dose hypersensitivity. LA R of cancer mortality according to the
LNT-model for paediatric chest CT or CT abdomen was 0.1 and 0.2 ‰.
Including the 3-H2 AX foci data, the LAR is 8-10 times higher.
Conclusion
Even when low dose equipment and specific protocols are used
CT X-rays induce DNA-damage in children. The present study emphasises the
need for justification and dose optimisation in paediatric radiology.
B-0952 14:09
Optimising the balance between radiation dose and image quality in
paediatric head CT: findings before and after intensive radiological staff
training
L. Faggioni, F. Paolicchi, L. Bastiani, S. Molinaro, M. Puglioli, D. Caramella,
C. Bartolozzi; Pisa/IT (
[email protected])
Purpose: To assess radiation dose and image quality of paediatric head CT
examinations before and after radiological staff training.
Methods
and Materials: 215 contrast-unenhanced head CT examinations
were performed in outpatients aged between 1 month and 14 years old before
and after intensive training of staff radiologists and technologists to
optimisation of CT technique. Patients were divided in three age groups (0-4,
5-9, and 10-14 years old), and pre- and post-training CT dose index (CTDI),
dose-length product (DLP), tube voltage (kV), and tube current per rotation
(mAs) values were retrieved from our hospital PACS. Pre- and post-training
grey matter conspicuity and contrast-to-noise ratio were calculated, and
subjective image quality in terms of artefacts, grey/white matter differentiation,
noise, visualisation of posterior fossa structures, and need for repeat CT
examination was visually evaluated by three neuroradiologists.
Results
Median post-training CTDI and DLP values were significantly lower
after than before training in all age groups (27 mGy and 338 mGy cm vs
107 mGy and 1444 mGy cm in the 0-4 years old group, 41 mGy and
483 mGycm vs 68 mGy and 976 mGy cm in the 5-9 years old group, and
51 mGy and 679 mGy cm vs 107 mGy and 1480 mGy cm in the 10-14 years
old group, respectively; p < 0.001). Post-training kV and mAs settings were
significantly lower compared to pre-training levels (p < 0.001). Subjective post-
training image quality was not inferior to pre-training levels for all items except
for noise (p < 0.05), which however was never diagnostically unacceptable.
Conclusion
Radiological staff training can be effective in reducing radiation
dose while preserving diagnostic quality of paediatric head CT examinations.
B-0953 14:18
European guidelines on paediatric chest x-rays: is our dedicated
paediatric division able to fulfil the standards quantitatively and
qualitatively?
S. Tschauner, M. Gübitz, R. Marterer, S. Weissensteiner, E. Sorantin; Graz/AT
(
[email protected])
Purpose: As paediatric patients are more susceptible to radiation, correct
collimation in chest X-rays helps to reduce unnecessary exposure. European
guidelines from 1996 define a minimal field size from "just above the lung
apices" to "T12/L1" plus tolerances of 2 cm. This study's aim was to check our
division's performance in the qualitative standards and measure overexposures
quantitatively.
Methods
and Materials: A total number of 307 unprocessed digital chest
images, acquired in June and July 2013, were selected for analysis. 14 studies
were excluded because of patient age greater than 18 years. The remaining
293 included patients had mean age of 6.28 years (SD 4.88, 0 to 17.87 years).
58% were boys, 42% girls. Overexposed areas plus amount of tissue on all
four sides were measured: Image analyses were done with a self-developed
ImageJ (open source image processing program) macro script.
Results
Examined patients' chest films showed a mean areal overexposure of
51.58% (SD 14.04%, range 15.99% to 107.88%) and the overexposed areas
included 70.33% (SD 10.31%) tissue on average. Areal overexposure was
found to decrease significantly with age.
Only 1% (3 out of 293) of our images fulfilled all quantitative and qualitative
parameters of the European guidelines.
Conclusion
In our samples we found a mean unnecessary overexposure by
more than half. As only a small minority of our division's chest films met all
European Commission criteria, constant and recurrent quality assurance is
necessary. On the other hand the mentioned guidelines may potentially be too
strict in some situations.
B-0954 14:27
Diagnostic reference ranges: a new quality improvement tool in
paediatric CT of the abdomen
M.J. Goske
1, K.J. Strauss1, L. Coombs2, A. Towbin1, D. Larson1, M. Callahan3,
K. Darge4, D. Frush5; 1Cincinnati, OH/US, 2Reston, VA/US, 3Boston, MA/US,
4Philadelphia, PA/US, 5Durham, NC/US (
[email protected])
Purpose: To develop diagnostic reference ranges (DRR) to be used as a
quality improvement tool for individual practices to compare their size-specific
dose estimates (SSDE) for 5 body widths (BW) with SSDE ranges from six
children's hospitals.
Methods
and Materials: A multicenter retrospective study was performed. CT
doses from September 1 to December 1, 2009 in 939 paediatric patients and
954 scans were reviewed through the American College of Radiology Dose
Index Registry. SSDE were measured at the level of the splenic vein in
transverse diameter. An appropriate dose range for each of 5 BW was
developed by reviewing image quality on a subset of CT scans and compared
to a 5 point reference scale created with the addition of simulated quantum
mottle.
Results
For 954 scans, DRR (SSDE mGy) were 5.8-12.0, 7.3-12.2, 7.6-13.4,
9.8-16.4, 13.1-19.0 mGy for BW less than 15, 15-19, 20-24, 25-29, and 30 cm
or greater.
Conclusion
DRR developed by a consortium of 6 children's hospitals
(QUIRCC) address the balance between a patient's risk (radiation dose) and
benefit (diagnostic image quality) and may be used by a local facility to
compare their practice to the QUIRCC ranges for the purpose of quality
improvement. Goske MJ et al. Radiology 2013; 268:208-218.
Author Disclosures:
D. Larson: Patent Holder; Guidance. D. Frush: Consultant; GE.
B-0955 14:36
Optimisation of image reconstruction method with sinogram affirmed
iterative reconstruction in pediatric CT: chest, abdomen and head
K. Lee, J. Park; Seoul/KR (
[email protected])
Purpose: To evaluate the image quality and clinical efficacy of pediatric CT
using a recently available sinogram affirmed iterative reconstruction (SAFIRE)
compared with filtered back-projection (FBP).
Methods
and Materials: From january to march 2013, 82 of pediatric CT
examinations were retrospectively divided into three groups which are based
on each anatomic region of abdomen, chest and head. each image was
reconstructed in soft tissue kernel by using standard FBP and 3 strength of
SAFIRE among 5 different SAFIRE strengths. a phantom study with same
protocol was also performed to analyse the relationship of noise reduction
among 5 different SAFIRE strengths on average.
Results
Three-strength of SAFIRE can reduce image noise by 23.73% in
chest (mean, 8.04), and 28.13% in abdomen (mean, 7.58) compared with each
FBP (each mean, 11.09 and 10.81). on the other hand, noise reduction
showed 15.53% in head (mean, 4.98) compared with FBP (mean, 6.30). in
phantom study, noise reduction patterns were similar to clinical patient's data.
the average noise reduction was as follows: 32.99% in chest CT, 27.78% in
abdomen CT and 18.54% for head CT, respectively. the figure of noise
reduction with five-strength of SAFIRE in head CT was similar to noise level
with three-strength of SAFIRE in chest and abdomen CT.
Conclusion
A choice of the appropriate iterative method is necessary to
achieve an optimal balance for image quality. when five-strength of SAFIRE is
utilised in pediatric head CT, the level of noise reduction is similar to three-
strength of SAFIRE in pediatric body CT.
B-0956 14:45
Evaluation of organ-specific dose reduction in paediatric chest computed
tomography
J. Boos, P. Kröpil, D. Klee, P. Heusch, G. Antoch, R. Lanzman;
Düsseldorf/DE (
[email protected])
Purpose: To assess the impact of a novel Organ-Specific Dose Reduction
(OSDR) algorithm on image quality of pediatric chest computed tomography
(CT).
Methods
and Materials: Twenty pediatric patients (8 male, 12 female; mean
age 12.4 ± 5.6 years (range 3-17 years)) undergoing contrast-enhanced chest
CT examinations on a 128-row-CT scanner were included. CT scans were
performed at 100 kV using automated tube current modulation and a novel
OSDR algorithm (XCare, Siemens AG, Forchheim, Germany). Nine patients
had a previous chest examination performed on a 64-row-CT scanner at
100 kV without the OSDR algorithm. Subjective image quality was assessed
using a five-point-scale (1- not diagnostic; 5- excellent) in all patients. In 9
children who underwent CT scans with and without OSDR, contrast-to-noise
ratio (CNR) and signal-to-noise ratio (SNR) were determined in the aorta.
Results
In 20 patients, mean subjective image quality was 4.3 ± 0.7. In 9
patients that were also examined without OSDR, subjective image quality was
S342
BA C D E F G
Monday
comparable with OSDR (4.4 ± 0.5) and without OSDR (4.4 ± 0.7)(p> 0.05).
Furthermore, there was no significant difference in mean SNR and CNR of the
aorta with OSDR (31.6 ± 17.1 and 22.3 ± 15.0, respectively) and without OSDR
(27.4 ± 13.3 and 18.8 ± 12.4, respectively) (p > 0.05). CTDIvol was comparable
for acquisitions with OSDR (2.3 ± 0.9 mGy) and without OSDR
(2.6 ± 1.9 mGy)(p> 0.05).
Conclusion
Organ-specific dose reduction can be recommended for pediatric
chest CT in order to reduce the radiation exposure to radiosensitive tissues as
the breast or thyroid gland
Author Disclosures:
G. Antoch: Speaker; Siemens Medical Solutions, Bayer Healthcare, BTG.
B-0957 14:54
Image quality and reconstruction time of CT angiography with model-
based iterative reconstruction in newborns and infants with congenital
heart disease
K. Choo, J. Roh, J. Hwang; Busan/KR (
[email protected])
Purpose: To evaluate image quality and reconstruction time of CT
angiography (CTA) with model-based iterative reconstruction (MBIR) in
newborns and infants with congenital heart disease (CHD) and to compare
with filtered back projection (FBP), adaptive statistical iterative reconstruction
(ASIR)
Methods
and Materials: Thirty-six consecutive children (age 4.79 ± 3.7
months, weight 4.79 ± 0.47 kg) with suspected or confirmed CHD underwent
64 detector MDCT (Discovery 750HD, GE health care) without ECG gating
(80 kVp, 30-40 mA using tube current modulation).The CT images were
reconstructed with FBP, ASIR and MBIR. Both objective and subjective image
quality (4 point scale) were compared according to reconstruction method. In
addition, each reconstruction time was also reported
Results
Images from all patients were diagnostic acceptable and total DLP
was 0.06 mSv. HU of MBIR was significantly higher than other two
reconstruction methods in ascending aorta and descending aorta (p < 0.05)
and image noise of MBIR was significantly lower than other two methods in all
chamber and great vessels (p 0.05). Each mean reconstruction time was 5.1
seconds in FBP, 5.1 seconds in seconds, 15.1 minutes in MBIR, respectively.
Conclusion
CTA with MBIR did not make a difference subjective image
quality and needed relatively long reconstruction time in the evaluation of CHD,
although image noise of MBIR was significant lower than one of FBP and ASIR
B-0958 15:03
Effect of tube voltage reduction on radiation dose and image quality in
paediatric thoracic 256 multidetector computed tomography
M. Cellina, B. Tagliaferri, A. Torresin, M. Maddalo, L. Trombetta, G. Oliva;
Milan/IT (
[email protected])
Purpose: To determine the effect of lowering tube-voltage on radiation dose
and image quality in chest MDCT in children.
Methods
and Materials: 30 children aged 2-10 years (6.8± 2.2 years),
weighting 12-30 kg (21.5 ±5.1 kg) underwent 256 chest MDCT. Acquisition
parameters were: tube-voltage 100 kV; reference current 130 mAs with
attenuation-based-tube-current-modulation; pitch 3; rotation-time 0.28 s;
collimation 3x 0.6 mm; image reconstruction-thickness 3 mm; position-
increment 3 mm. A second group of 30 patients with similar characteristics
(age range: 2-10 years; mean: 6.2 ±2.1 yy; weight range: 12-30 kg; mean:
20.9±5 kg)underwent chest MDCT with the same parameters, except tube
voltage: 80 kV. Image quality, artefacts, diagnostic confidence were evaluated
for the 2 groups by 2 radiologists in consensus, blind to kV, using a 5-point-
grading-scale (1=unacceptable; 5= perfect). Image noise was calculated by
placing a region of interest at ambient air at the same 3 levels (aortic arch,
carina, the first slice in which right diap hgram is visible) measuring the average
of the standard deviations in HU. Effective doses were calculated using DPL
Method
with accepted age-dependent-convertion-factors.
Results
Mean image quality, artefacts and diagnostic confidence were for
group 1 vs group 2: 4.6 ±0.5 vs 4.5±0.6, 4.6±0.4 vs 4.4±0.5; 4.7±0.4 vs 4.5±0.5,
without statistically significant difference (p=0.19, 0.11, 0.14, respectively).
Mean image noise was 12.9± 5 HU for group 1 and 13.4 ±6 for group 2
(p=0.22). Mean effective radiation doses in the 2 groups were statistically
different: 1.4±0.7 mSv vs 0.8±0.2 mSv (p=0.01).
Conclusion
Our findings support the practice of lowering tube-voltage to
80 kV for paediatric chest MDCT.
B-0959 15:12
Definition of a scoring system for assessment of skeletal age using MRI
of hand and wrist in healthy male children
S. Battisti
1, M. Martino1, K. Rodacki2, E. Tomei1, R. Semelka3; 1Rome/IT,
2Blumenau/BR, 3Chapel Hill, NC/US (
[email protected])
Purpose: To evaluate skeletal age determination, using Magnetic Resonance
Imaging (MRI) of hand and wrist by creating a scoring system method.
Methods
and Materials: 96 healthy young male (mean age 14.2 ±3.7; range
1y 6m to 19y 1m). Two operators (A, B) prior in consensus established a
prototype of scoring system to establishi ng MRI skeletal age using as basis the
anner and Whitehouse x-ray method. The scoring system was based on
different grade of maturity carpal bones (range from 1 to 12 grades). To test
the method two operators in double blind assigned a MRI skeletal age.
Correlation between chronological age and MRI skeletal age was determined
by linear regression analysis (R 2). k-Cohen was used to measure inter-
observator variability and inter-rater reproducibility. Spearman' correlation
coefficient (r) was used to analyse each carpal bone stage development.
Results
A strong positive linear correlation was obtained between MRI
skeletal age and chronological age (R 2=0.976, 0.978; A, B respectively)). k-
Cohen test demonstrated a pretty good values (reproducibility=0.6 and
repeatability =0.7). The Radius and Ulna showed the strongest correlation with
the MRI skeletal age (r=0.96 and 0.963 p= < 0.0001). A good linear correlation
between sum of the scoring system and chronological age was observed
(R2=0.96).
Conclusion
MRI skeletal age estimation can be potentially used as a clinical
tool to identify with more details cartilage and bone ossification during skeletal
development. A non-invasive method to determinate bone age is clinically
important in children to avoid radiation exposure.
B-0960 15:21
ECG-gated CT angiography in 324 consecutive pediatric patients:
predictors of radiation dose
F.G. Meinel
1, T. Henzler2, P.A. Park1, U.J. Schoepf1, C.N. De Cecco1,
A.J. Lewis1, J.V. Spearman1, A.M. Hlavacek1; 1Charleston, SC/US,
2Mannheim/DE (
[email protected])
Purpose: We aimed to identify the main determinants of radiation exposure
from pediatric ECG-gated CTA.
Methods
and Materials: Between June 2005 and June 2013, 324 ECG-gated
CTAs were performed to evaluate pediatric patients with known or suspected
cardiovascular abnormalities (median age 8.1 years). The effective dose (ED)
was calculated from the dose-length product (DLP) using age-specific
correction factors. The patients' age and average heart ratie during the scan,
the method of ECG-synchronisation, tube potential (kV) and effective tube
current (mAs) were analysed in univariate and multivariate regression analysis
to identify predictors of radiation dose.
Results
Overall, the median ED was 1.85 mSv (range: 0.07 - 30.7 mSv).
Median radiation exposure decreased from 13.38 mSv for patients examined in
the years 2005-2007 to 1.25 mSv for patients examined in the years 2011-
2013 (p < 0.001). Patients scanned using a tube potential of 80 kV (n=259) had
a significantly lower median radiation dose (1.41 mSv, range 0.07-8.64 mSv)
compared to patients who were scanned at 100 kV (n=46, median 6.3 mSv,
range 1.26-14.83 mSv) or 120 kV (n=19, median 18.63 mSv, range 4.28-30.67
mSv, p < 0.001). On multivariate analysis, tube voltage, followed by tube
current and the method of ECG-synchronisation were the strongest
independent predictors of radiation dose.
Conclusion
The radiation exposure from pediatric ECG-gated CTA has
decreased dramatically in recent year s. With dedicated pediatric protocols,
ECG-gated CTA can now be routinely performed with very low radiation
exposure.
Author Disclosures:
U.J. Schoepf: Consultant; Bayer, Bracco, GE, Medrad, Siemens.
Research/Grant Support; Bayer, Bracco, GE, Medrad, Siemens.
S343
BA C D E F G
Monday
14:00 - 15:30 Room E1
Musculoskeletal
SS 1810
Knee osteoarthrosis
Moderators:
F.M. Buck; Zurich/CH
J. Labuscagne; Bunbury, WA/AU
B-0961 14:00
Subchondral bone oedema after matrix-assisted autologous chondrocyte
transplantation: MRI evaluation at different follow-up times
M. Busacca, D. Capannelli, A. Moio, E. Kon, G. Filardo, U. Albisinni;
Bologna/IT (
[email protected])
Purpose: Subchondral bone oedema is a common finding after cartilage
treatment but its interpretation is still debated. The aim of this study is to
analyse the presence of oedema after matrix-assisted autologous chondrocyte
transplantation (MACT) for knee cartil age lesions at different follow-up times
and its correlation with clinical outcome.
Methods
and Materials: 116 patients (mean age 28.6 ±10.3 yrs) treated with
MACT underwent 1.5-T MRI. 57 patients were affected by degenerative
cartilage lesions, 27 traumatic and 32 OCDs (osteochondritis dissecans). MRI
follow-up was performed from 1 to 5 years after treatment. A standard
sequence protocol was optimisated for the study of articular cartilage and
subchondral bone. Other than its presence or absence, the subchondral
oedema was evaluated using a 3-level grading considering extension and
hyper-intensity, and with the WORMS score oedema classification. IKDC
subjective score was collected at the time of every MRI.
Results
Subchondral oedema presents a particular and well-defined trend
during the follow-up: it was present in the first period and markedly reduced or
disappeared at 2-3 years. Afterwards level of oedema increased again and
remained steadily present at medium/long-term follow-up. Patellar lesions
presented significantly lower oedema, whereas OCDs presented an increasing
level of oedema over time. No correlation found between oedema and clinical
outcome.
Conclusion
Edema after MACT is present during the first phases to 2 years
of follow-up, and then tends to disappear. Less oedema was found in patella,
whereas more oedema was found in OCDs. Interestingly, presence of oedema
was not correlated with poorer clinical outcome.
B-0962 14:09
Meniscal lesions and effusion synovitis assessed by semiquantitative
MRI strongly predict quantitatively measured cartilage thickness loss
over 30 months: multicenter osteoarthritis study
A. Guermazi
1, F. Eckstein2, D. Hayashi1, F.W. Roemer1, W. Wirth2, T. Yang1,
J. Niu1, L. Sharma3, D. Felson1; 1Boston, MA/US, 2Salzburg/AT, 3Chicago,
IL/US (
[email protected])
Purpose: Aims were to examine which pathological MRI and radiographic
features of knee osteoarthritis (OA) are most predictive of quantitative cartilage
thickness loss measured by MRI.
Methods
and Materials: A subcohort of 196 subjects from the MOST
participants had baseline and 30-mo nth knee MRIs, quantitative cartilage
thickness measurement, and semiquantitative scoring (Whole Organ MRI
Score) of cartilage, bone marrow, meniscus, effusion-synovitis, and Hoffa-
synovitis at both time points. Radiographic joint space narrowing (JSN) was
assessed at baseline. Knees were classified into progressors (those who lost
cartilage thickness above thresholds) and non-progressors. MRI predictors
were dichotomized into present or absent. Differences in baseline scores of
ipsicompartmental predictor variables were compared between progressors
and non-progressors by logistic regression. Odds ratios (OR) were calculated
for medial (MFTC) and lateral femorotibial compartment (LFTC) cartilage loss.
We combined MFTC and LFTC to calculate ORs of ipsicompartmental cartilage
loss across compartments.
Results
Of 196 knees (mean age 59.8 ±6.3, BMI 29.5± 4.6), 46 had
radiographic OA at baseline. Compared to non-progressors (n=149),
progressors (n=47) had higher adjusted OR (aOR) for having baseline medial
meniscal damage (MD) (aOR 2.4 [95%CI 1.2-5.1]), medial meniscal
extrusion (ME) (aOR 2.5 [1.2-5.3]) and effusion-synovitis (aOR 3.2 [1.2-8.2]) in
MFTC. In LFTC, baseline JSN (aOR 7.0 [1.8-27.1]), lateral MD (aOR 8.1 [2.5-
26.6]) and lateral ME (aOR 4.1 [1.4-12.5]) predicted cartilage loss. In analysis
combining MFTC and LFTC, results were similar to LFTC, with baseline
compartment specific JSN, MD/ME predicting cartilage loss.
Conclusion
Meniscal damage/extrusion and effusion-synovitis assessed by
semiquantitative MRI strongly predict quantitatively measured cartilage
thickness loss over 30 months.
Author Disclosures:
A. Guermazi: Consultant; TissueGene, Merck Serono, Sanofi Aventis.
Shareholder; Boston Imaging Core Lab. F. Eckstein: CEO; Chondrometrics
GmbH. Consultant; MerckSerono, Abbvie. Owner; Chondrometrics
GmbH. F.W. Roemer: Consultant; MerckSerono, NIH. Shareholder; Boston
Imaging Core Lab. L. Sharma: Grant Recipient; NIH. D. Felson: Grant
Recipient; NIH.
B-0963 14:18
Knee pain and inflammation in the infrapatellar fat pad estimated by
conventional and dynamic contrast-enhanced magnetic resonance
imaging in obese patients with osteoarthritis: a cross-sectional study
C. Ballegaard1, R. Riis1, R. Christensen1, M. Henriksen1, E. Bartels1,
S. Lohmander2, D. Hunter3, R. Bouert1, M. Boesen1; 1Frederiksberg/DK,
2Lund/SE, 3Sydney/AU (
[email protected])
Purpose: To investigate the association between knee pain and signs of
inflammation in the infrapatellar fat pad (IPFP) in obese patients with knee
osteoarthritis (KOA).
Methods
and Materials: In a cross-sectional setting, 3-T conventional
contrast-enhanced (CE) magnetic resonance imaging (MRI) and dynamic
contrast-enhanced (DCE) MRI of KOA were analysed to quantify the extent of
inflammation in the IPFP, and correlated to self-reported outcomes on pain,
symptoms and quality of life assessed via the Knee injury and Osteoarthritis
Outcome Score (KOOS). The extent of inflammation in the IPFP was assessed
according to MOAKS (MRI Osteoarthritis Knee Score) using CE-MRI and by
perfusion variables using DCE-MRI. The perfusion variable, "Inflammation", -
IRE x (N-plateau+N-washout), was chosen as primary perfusion variable in the
analysis.
Results
MRI and clinical data were obtained in 95 patients. The typical patient
participating in this study was a 65-year-old woman with a body mass index of
32 kg/m
2. The bivariate association between KOOS pain and the DCE-MRI
perfusion variable "Inflammation" showed a statistically significant correlation
(r=-0.42, p < 0.0001). Furthermore, a statistical ly significant correlation was
found between KOOS pain and MOAKS Hoffa-synovitis (r=-0.21, p=0.046).
Intraclass correlation coefficients for the perfusion variables ranged from 0.81
to 0.99.
Conclusion
Perfusion variables on DCE-MRI reflecting inflammation in the
IPFP and MOAKS Hoffa-synovitis were related to pain in obese patients with
KOA. These results suggest that increasing inflammation in the IPFP is
associated with increasing pain in KOA and that DCE-MRI is a robust and
reproducible method to study the impact of inflammation in KOA.
Author Disclosures:
D. Hunter: Other; DH has received royalties from DJO. R. Bouert: Other; RB
has acted as independent non-paid clinical advisor for Image Analysis Ltd,
London. M. Boesen: Other; MB has acted as independent non-paid clinical
advisor for Image Analysis Ltd, London.
B-0964 14:27
Dynamic contrast-enhanced MRI in patellofemoral pain syndrome:
perfusion quantification of patellofemoral joint tissues
R.A. van der Heijden, D.H.J. Poot, E.E. Bron, S. Klein, J.A.N. Verhaar,
S.M.A. Bierma-Zeinstra, M. van Middelkoop, G. Kotek, E.H.G. Oei;
Rotterdam/NL (
[email protected])
Purpose: Patellofemoral pain syndrome (PFPS) is a common knee pathology
with unknown aetiology. A hypothesis on the aetiology is a disturbed blood flow
in the patellofemoral joint. Dynamic contrast-enhanced MRI (DCE-MRI)
enables us to study perfusion, but there is no tailored method for the
patellofemoral joint yet. In this study, we developed and evaluated a DCE-MRI
protocol with dedicated post-processing tool, enabling perfusion quantification
of patellofemoral joint tissues in order to disentangle the aetiology of PFPS.
Methods
and Materials: We evaluated our method in 5 control subjects from
an ongoing DCE-MRI study in PFPS and control subjects. Sagittal DCE image
slices with SI phase encoding were acquired at 3 T using a 8-channel knee
coil. Our volume of interest (VOI) consisted of the patellar bone. Motion
between scans was corrected for by automated image registration. Voxel-wise
quantitative perfusion parameters (kep) were calculated with Tofts model.
Since precision of kep varies spatially, weighted mean and standard deviation
were computed over the VOI, with weights given by the reciprocal Cramér-
Rao-Lower-Bound (indicating fit uncertainty).
Results
Weighted mean kep values of the patellar bone ranged between
0.045 and 0.071 s
-1, which is in correspondence with the literature. The mean
weighted standard deviation in the VOI was 0.031 s -1, suggesting
heterogeneous perfusion within the patella.
Conclusion
The results suggest that our DCE-MRI protocol and post-
processing tool are adequate, and can be used to study patellar blood
perfusion. Quantitative kep maps even allow study of regional perfusion. This
may yield important information on the aetiology of PFPS.
S344
BA C D E F G
Monday
B-0965 14:36
Diffusion-weighted imaging for the assessment of knee synovitis: a
comparative study against contrast-enhanced MRI
E.H.G. Oei, E.J. McWalter, B. Sveinsson, M.T. Alley, B.A. Hargreaves,
G.E. Gold; Stanford, CA/US (
[email protected])
Purpose: MRI of synovitis currently requires contrast-enhanced imaging which
increases cost, risks, and imaging time. The novel 3D double echo steady
state (DESS) sequence can be modified by increasing diffusion weighting,
thereby improving contrast between synovium and joint fluid. Our purpose was
to compare DESS with contrast-enhanced (CE) MRI for knee synovitis
assessment.
Methods
and Materials: Nine individuals with symptomatic inflammatory knee
arthritis underwent MRI at 3.0 T. Routine clinical sequences were performed
followed by the modified 3D DESS sequence (matrix 256x256; slice thickness
3 mm; duration 5:00 minutes) with high diffusion (10 cycles/voxel) gradient and
CE T1-weighted imaging (matrix 384x256;slice thickness 3 mm; duration
4:30 minutes). DESS and CE MRI images were scored independently by a
blinded musculoskeletal radiologist. Synovi tis was graded semiquantitatively at
11 sites and a whole-joint sum score was calculated according to Guermazi
etal. Agreement statistics were calculated on site and patient levels and whole-
joint synovitis scores of DESS were correlated with those of CE MRI
(reference).
Results
DESS showed good agreement (86% and 77% based on analysis on
patient and site level respectively) with CE MRI for detection of synovitis, but
systematically underestimated synovitis severity (61% absolute agreement
analysed by site). Excellent correlation was found between summed whole-
joint synovitis scores of DESS and CE MRI (Pearson's correlation coefficient
0.85 (p=0.016), intra-class correlation coefficient 0.82 (95%CI 0.28-0.97)).
Conclusion
Diffusion weighted imaging with a modified 3D double echo
steady state (DESS) sequence with high diffusion gradient is promising for the
(semiquantitative) assessment of knee synovitis without need for contrast
agents.
Author Disclosures:
B.A. Hargreaves: Research/Grant Support; General Electric Healthcare. G.E.
Gold: Consultant; Zimmer, Boston Scientific, Isto Inc. Research/Grant Support;
General Electric Healthcare.
B-0966 14:45
Relationship of total hip arthroplasty to ipsilateral and contralateral knee
osteoarthritis: a 4-year longitudinal 3 T MRI study from the osteoarthritis
initiative
P.M. Jungmann
1, M.C. Nevitt2, H. Liebl1, L. Nardo2, T. Baum1, F. Liu2,
N.E. Lane3, C.E. McCulloch2, T.M. Link2; 1Munich/DE, 2San Francisco, CA/US,
3Sacramento, CA/US (
[email protected])
Purpose: To evaluate the association of unilateral total hip arthroplasty (THA)
with the prevalence and worsening of OA degenerative changes and strength
in the ipsilateral and contralateral knee.
Methods
and Materials: We studied both knees of 30 individuals in the
osteoarthritis Initiative (OAI) with pr evalent unilateral THA at baseline. We
compared knees ipsilateral and contralateral to THA within each subject on
baseline values, and change over 4 years, in Western Ontario and McMasters
Universities Arthritis Index (WOMAC) scores, upper leg isometric strength,
whole-organ MR imaging scores (WORMS) and (in right knees) cartilage T2
relaxation time measurements. Ipsilateral and contralateral knees were
compared using multivariate regression models and paired t-tests.
Results
WOMAC scores did not differ between knees at baseline, but there
was a trend for greater contralateral knee worsening of WOMAC pain (paired t-
test, P=0.087), stiffness (P=0.039), physical function (P=0.057) and total
scores (P=0.059) in subjects with unilateral THA. Strength did not differ
between knees at baseline, but contralateral extension strength declined more
over 4 years (P=0.037) than ipsilateral. Contralateral knees had higher
cartilage scores (P=0.007) and total WORMS scores (P=0.008) at baseline.
Total WORMS score also showed greater worsening over 4 years (P=0.008).
Baseline T2 was not significantly different between knees, but T2 values
increased more in knees contralateral to THA (mean ±SEM, 2.9±1.4 ms versus
0.2±1.1 ms; P=0.007).
Conclusion
THA is associated with an increased progression of degenerative
findings in the contralateral knee compared to the ipsilateral knee.
B-0967 14:54
Association of T2 relaxation time measurements with different grades of
radiographic knee osteoarthritis over 48 months - data from the
Osteoarthritis Initiative
U.R. Heilmeier
1, H. Liebl2, L. Nardo1, M. Kretzschmar1, S. Lee1, G.B. Joseph1,
C.E. McCulloch1, M.C. Nevitt1, T.M. Link1; 1San Francisco, CA/US,
2Munich/DE
Purpose: To analyse the cross-sectional and longitudinal association between
cartilage biochemical composition (a s measured by MRI T2) and various
stages of radiographic OA as defined by Kellgren-Lawrence (KL-)-score.
Methods
and Materials: Right knee 3 Tesla MRI studies of 190 subjects (105
female, 85 male, aged 45-70, BMI 24.7 ±2.4) from the Osteoarthritis Initiative
were selected based on their baseline radi ographic KL-readings and stratified
into 4 KL-groups (KL 0-3). Knee cartilage was segmented at baseline, 2-year
and 4-year follow-up. Mean cartilage T2 quantification as well as laminar- and
GLCM-texture analysis were performed at each timepoint. Global mean T2
values and T2 changes over time were calculated for each KL-group.
Regression models adjusted for age, gender, and BMI were used to determine
the difference in cartilage T2 parameters between KL-groups.
Results
Subjects with KL-grades of 1, 2 or 3 showed significantly higher
global mean T2 values than subjects with KL0, at baseline (p < 0.005;
p < 0.001, p < 0.001), at 24 months (p=0.001; p < 0.001, p=0.044) and 48
months (p < 0.001; p=0.002, p < 0.001). Texture and laminar cartilage analyses
revealed additional signi ficant T2-differences between KL1 and KL3 (p=0.004)
and KL2 and KL3 (p=0.031) at most timepoints. The annual increase in mean
T2 was similar for each KL-group and ranged from 0.36 ms/yr in KL1 subjects
to 0.25 ms/yr in KL3 subjects (p=0.61).
Conclusion
Our findings suggest that T2 relaxation time measurements, and
particularly laminar and texture cartilage analyses, can depict different degrees
of osteoarthritis related cartilage damage cross-sectionally and longitudinally,
and might therefore be promising tools to monitor osteoarthritis progression.
B-0968 15:03
Delayed gadolinium-enhanced MRI of the Meniscus (dGEMRIM) in
patients with knee osteoarthritis: relation with meniscal degeneration on
conventional MRI, reproducibility, and correlation with dGEMRIC
J. van Tiel, G. Kotek, M. Reijman, P.K. Bos, S. Klein, J.A.N. Verhaar,
G.P. Krestin, H. Weinans, E.H.G. Oei; Rotterdam/NL (
[email protected])
Purpose: (I) To assess if menisci identified as normal or degenerated on
conventional MRI differ in T1 relaxation times of delayed gadolinium-enhanced
MRI (T1GD), (II) to assess the reproducibility of T1GD of the meniscus and (III)
to assess the correlation between T1GD of the meniscus and the articular
cartilage in knee osteoarthritis (OA) patients.
Methods
and Materials: In 17 OA patients who underwent delayed
gadolinium-enhanced MRI twice within 7 days, we calculated T1GD in the
medial and lateral anterior and posterior meniscus and femoral and tibial
cartilage. Meniscus pathology was evaluated on conventional MRI. T1GD in
normal and degenerated menisci were compared using an unpaired t-test.
Reproducibility of T1GD was assessed using intraclass correlation coefficients
(ICC). Pearson's correlation coefficient was calculated between meniscus and
cartilage T1GD.
Results
A trend towards lower T1GD in degenerated menisci (mean: 448 ms,
95%CI: 423-473 ms) compared to normal menisci (mean: 402 ms, 95%CI: 359-
444 ms) was observed (p=0.05). ICCs of meniscus T1GD ranged from 0.85 to
0.90. The correlation between meniscus and cartilage T1GD was moderate in
the lateral compartment (r=0.52-0.75) and strong in the medial compartment
(r=0.78-0.94).
Conclusion
Degenerated menisci have a clear trend towards lower T1GD
compared to normal menisci. Since thes e results are highly reproducible,
meniscus degeneration might be assessed within one delayed gadolinium-
enhanced MR examination simultaneously with articular cartilage. The strong
correlation between meniscus and cartilage T1GD indicates concomitant
degeneration in both structures in OA, but also suggests that dGEMRIC may
not be regarded entirely sulphated glycosaminoglycan specific.
Author Disclosures:
G.P. Krestin: Consultant; General Electric Healthcare. Grant Recipient;
General Electric Healthcare.
S345
BA C D E F G
Monday
B-0969 15:12
Knee joint space measurements on computer automatically aligned
images vs conventional reconstructions
A. Chabra,1, Z. Peng2, X. Zhou2, C. Florin2; 1Dallas, TX/US, 2Malvern, PA/US
(
[email protected])
Purpose: To evaluate the time and measurement differences for the
interpretation of knee joint space measurements on computer auto-aligned CT
images versus conventional reconstructions.
Methods
and Materials: 30 randomly selected CT scans of the knee (mean
age 51 yrs, range 12-76 yrs), all performed on 64-slice scanner, reconstructed
at 0.75-3 mm slice thickness. These scans were reviewed by experienced
musculoskeletal radiologist who measured joint space in the medial, lateral and
patella-femoral compartments of the knee on conventional coronal and axial
images (CCT). The same measurements were then performed on computer
auto-aligned CT images (ACT) obtained by an algorithm prototype using
anatomical landmarks to reorient the images for optimal display of the knee
joint space. Differences in joint space measurements and time for evaluation
were assessed.
Results
The mean medial-tibio-femoral space on CCT was 3.2 mm (range
1.1-8.2 mm, SD-1.4 mm), and on ACT was 3.2 mm (range 1.1-7.9 mm, SD-
1.5 mm) (p-value 0.06). The mean lateral-tibio-femoral space on CCT was
4.5 mm (range 1.5-7.9 mm, SD-1.6 mm), and on ACT was 4.7 mm (range 1.5-
11.1 mm, SD-2.3 mm) (p-value 0.30). The mean lateral-patella-femoral space
on CCT was 3.2 mm (range 1.4-5.8 mm, SD-0.9 mm), and on ACT was
3.3 mm (range 1.5-6.8 mm, SD-1.3 mm) (p-value 0.20). The mean time for
evaluation of the three measurements on CCT was 47.6 sec (range 27-110
sec, SD-15 sec), and on ACT was 33.8 sec (range 25-77 sec, SD-10 sec). The
difference was statistically significant (pvalue < 0.001).
Conclusion
Computer auto-alignment of CT image reconstructions (ACT)
allows significantly faster evaluation time without statistically significant impact
on the results of joint space measurements. It can save radiologists' time and
potentially lead to cost savings.
Author Disclosures:
A. Chhabra,: Consultant; Siemens Medical Solutions USA, Inc. Z. Peng:
Employee; Siemens Medical Solutions USA, Inc. X. Zhou: Employee; Siemens
Medical Solutions USA, Inc. C. Florin: Employee; Siemens Medical Solutions
USA, Inc.
B-0970 15:21
Weight-bearing CT of the knee: does the joint alignment change from
supine to upright position?
A. Hirschmann, F.M. Buck, S. Fucentese, C.W.A. Pfirrmann; Zurich/CH
(
[email protected])
Purpose: To compare patellofemoral and femorotibial joint alignment in supine
non-weight-bearing (NWBCT) and upright weight-bearing computed
tomography (WBCT).
Methods
and Materials: Institutional review board approval and informed
consent of all patients were obtained. NWBCT and WBCT scans of the knee
were obtained of 26 patients (mean age, 57.0 ± 15.9) using a 64-row CT for
NWBCT and a novel cone-beam extremity CT for WBCT. Two musculoskeletal
radiologists quantified joint alignment by measuring femorotibial rotation, tibial
tuberosity-trochlear groove distance (TTTG), lateral patellar tilt angle (LPTA),
lateral patellar shift (LPS), and medial and lateral femorotibial joint space width.
Significant differences between NWBCT and WBCT were sought using
Wilcoxon signed-rank test. P values < 0.05 were considered statistically
significant.
Results
Significant differences were found for femorotibial rotation
(P=0.051/P=0.009;reader 1/reader 2), TTTG (P=0.008/P=0.002), LPTA
(P=0.011/P=0.188) and medial joint space width (P=0.003/P=0.004).
Femorotibial rotation changed from NWBCT (mean 0.0° ± 6.1 internal rotation)
to WBCT (3.6° ± 6.8 external rotation). TTTG decreased from NWBCT
(13.8 mm ± 5.1/13.8 mm ± 3.9) to WBCT (10.5 mm ± 5.0/10.9 mm ± 5.2).
LPTA decreased from NWBCT (15.6° ± 6.7/16.9° ± 7.4) to WBCT
(12.5° ± 7.7/15.0° ± 6.2). The medial femorotibial joint space decreased from
NWBCT (3.9 mm ± 1.4/4.5 mm ± 1.3) to WBCT (2.9 mm ± 2.2/3.5 mm ± 2.2).
Interreader agreement was in average good to excellent (0.42-0.88).
Conclusion
Knee joint alignment significantly changes in the upright weight-
bearing position using CT.
B-0971 15:30
Quantitative assessment of biological expression and physiological
imaging in the experimental osteoarthritis
W. Yao; Shanghai/CN (
[email protected])
Purpose: To evaluate the relations among the level of cytokines in rabbits'
serum, quantitative parameters of MR physiological imagings (T2, T2*
relaxation time) and pathology of experimental osteoarthritis.
Methods
and Materials: 18 New-Zealand White rabbits were manufactured to
be animal models of experimental osteoarthritis, and divided into 6 groups by
weeks (2, 4, 8, 12, 16, 20), another 6 rabbits as the control group by means of
pseudosurgery. The concentration of BMP-2,CTX-II and COMP in rabbits'
serum were recorded. Every left knee of each group was scanned by MR Pd-
WI, T2 mapping and T2* mapping imaging accordingly and T2 and T2* values
of the articular cartilage in 10 subregions based on the Whole-Organ MRI-
Score were calculated. Differences were analysed and compared with the
concentration of cytokines by biochemical analysis and HE staining.
Results
The T2 relaxation time were 21.33, 20.21, 17.85, 25.61 ms at the
time of 8.12,16, 20 weeks after the surgery (P < 0.05, compared to their control
groups, respectively). The mean T2* relaxation time was 9.07 ms before
operation and elevated by 1.39.1.83, 3.33.14.6, 5.02, 3.31 ms, respectively, at
different time points. They are closely related to the difference of BMP-2, CTX-
II and COMP (r1=0.6, r2=0.72, r3=0.68). The difference of BMP-2 and CTX-II
within every group was statistically significant. HE staining demonstrated that
the proportion and extent of injured cartilage increased along with the
prolonged moulding time.
Conclusion
The T2,T2* relaxation time can depict injury extent of articular
cartilage of osteoarthritis and they are closely related to the concentration of
BMP-2,CTX-II,COMP in the serum reflecting different periods of cartilage
damage as well.
Author Disclosures:
W. Yao: Research/Grant Support; NSFC (No. 81171312).
14:00 - 15:30 Room E2
GI Tract
SS 1801b
Bowel imaging: advancing the use of US,
CT and MRI
Moderators:
A. Graser; Munich/DE
C. Stoupis; Männedorf/CH
B-0972 14:00
Reducing image noise in CT colonography: effect of an integrated circuit
CT detector
C.H. McCollough, Y. Liu, S. Leng, G. Michalak, T.J. Vrieze, X. Duan, M. Qu,
M.M. Shiung, J.G. Fletcher, K. Grant; Rochester, MN/US
Purpose: To investigate whether an integrated circuit (IC) CT detector results
in reduced noise in CT colonography (CTC).
Methods
and Materials: 366 consecutive patients underwent clinically-
indicated CTC using the same CT scanner system, except for a difference in
CT detectors (IC or conventional). Image noise, patient size, and scanner
radiation output (CTDI
vol) were quantitatively compared between the patient
cohorts for each detector system, with separate comparisons for the abdomen
and for the pelvis.
Results
For the abdomen and the pelvis, despite significantly larger patient
sizes in the IC detector cohort (both p < 0.001), image noise was significantly
lower (both p 0.05). Based
on the observed image noise reduction, radiation dose could alternatively be
reduced by approximately 20% to result in similar levels of image noise.
Conclusion
CTC images acquired using the IC detector had significantly
lower noise than using the conventional detector. This noise reduction can
permit further radiation dose reduction in CTC.
Author Disclosures:
C.H. McCollough: Grant Recipient; Siemens Heatlthcare. G. Michalak:
Employee; Siemens Medical Solutions. J.G. Fletcher: Grant Recipient;
Siemens Heatlthcare.
S346
BA C D E F G
Monday
B-0973 14:09
CT colonography with rectal iodine tagging: evaluation of diagnostic
accuracy, patient acceptance and overall examination time
L. Faggioni1, A. Mantarro1, E. Neri1, P. Bemi1, R. Scandiffio1, G. D'Ippolito2,
C. Bartolozzi1; 1Pisa/IT, 2São Paulo/BR (
[email protected])
Purpose: To assess diagnostic accuracy and image quality of CT
colonography (CTC) with rectal iodine tagging.
Methods
and Materials: Thirty-five asymptomatic patients with 57 colonic
lesions sized 6-30 mm underwent CTC for colorectal cancer screening. Patient
preparation consisted of a three-day low-residue diet plus Macrogol 4000 and
Bisacodyl after lunch, followed by a 50 mL enema of diatrizoate dimeglumine
(Gastrografin™) diluted in 300 mL warm tap water and automatic insufflation
with 3L carbon dioxide immediately before CTC. CTC findings were compared
with optical colonoscopy, and per-segment image quality was assessed using
a semiquantitative score (1=poor, 2=adequate, 3=excellent). Tagging quality,
patient acceptance, and total examination time of 80 unremarkable CTC
studies (40 performed with rectal tagging and 40 with oral tagging) were
evaluated.
Results
Overall tagging quality and patient acceptance were comparable with
rectal and oral tagging, while total exami nation time was significantly lower with
rectal tagging (18.3 ±3.5 vs 215.6± 10.3 minutes, p < 0.0001). Per-segment
image quality of CTC with rectal tagging was adequate to excellent in all
colonic segments, with a sensitivity and sp ecificity in lesion detection of 100%
and 100% in the sigmoid-rectum, 100% and 96.7% in the descending colon,
100% and 89.3% in the transverse colon, and 100% and 95.2% in the caecum-
ascending colon, respectively. Per-lesion sensi tivity and specificity were 94.6%
and 98.8% for lesions sized 6-9 mm, and 100% and 99.4% for lesions sized
10-30 mm, respectively.
Conclusion
Rectal iodine tagging can be an effective and well-tolerated
alternative to oral tagging for CTC with the advantage of a substantially shorter
overall examination time.
B-0974 14:18
Structured reporting of CT colonography examinations to support
national data registries and outcomes analyses
D.J. Vining1, T. Yang1, U. Salem1, C. Popovici2, A. Pitici2, A. Prisacariu2,
M. Jurca2; 1Houston, TX/US, 2Chapel Hill, NC/US (
[email protected])
Purpose: Standardised reporting of CT colonography (CTC) is essential for the
effective communication of diagnostic results, tracking of patient outcomes,
outcomes analyses, and support of national data registries including the
American College of Radiology's (ACR) CTC Data Registry. Various imaging
systems exist for the creation and interpretation of 2D and 3D CTC images, but
no standardised reporting methods have been proposed. We present a
multimedia structured reporting solution, called ViSion, which can be used to
standardise the reporting of CTC exams, code results with C-RADS criteria,
and automate data entry into international registries.
Methods
and Materials: We developed a multimedia structured reporting
system, called ViSion, which can function with any CTC image display and
interpretation workstation. ViSion tags key images captured from a CTC image
processing system with metadata describing the anatomical location of a
finding, radiological observation/diagnosi s, and disease metrics. Furthermore,
the radiological findings can be linked to pathology outcomes in graphical
disease timelines to support outcomes analyses. The data contained within a
ViSion structured report can be transported automatically into national data
registries.
Results
We applied the ViSion structured reporting system to 100 CTC cases
performed at our institution to create standardised CTC reports which were
subsequently uploaded into the ACR's CTC Data Registry.
Conclusion
The practice of radiology is undergoing a transition from narrative
reporting to structured reporting. We have developed a structured reporting
system that can be used to standardise the reporting of CTC examinations,
support international disease registries , and conduct data mining for outcomes
analyses.
Author Disclosures:
D.J. Vining: CEO; VisionSR, Inc. Founder; VisionSR, Inc. Shareholder;
VisionSR, Inc. C. Popovici: Employee; Eloquentix, Inc. A. Pitici: Employee;
Eloquentix, Inc. A. Prisacariu: Employee; Eloquentix, Inc. M. Jurca:
Employee; Eloquentix, Inc.
B-0975 14:27
MR colonography including diffusion-weighted imaging (DWI) in children
and adolescents with inflammatory bowel disease (IBD): do we really
need intravenous contrast?
S. Sirin, S. Kathemann, B. Schweiger, M. Hahnemann, M. Forsting,
T.C. Lauenstein, S. Kinner; Essen/DE (
[email protected])
Purpose: MR colonography (MRC) is a well-accepted, non-invasive imaging
modality for the depiction of inflammatory bowel disease. Diffusion-weighted
imaging (DWI) has been shown to show lesions in abdominal MRI as good as
contrast-enhanced imaging and can also be used for bowel imaging. Aim of
this study, therefore, was to assess if contrast enhancement is really needed to
depict inflammatory lesions in bowel MRI if DWI is available.
Methods
and Materials: 37 patients (23 girls, 14 boys, mean age 14.6years)
underwent MRC on a 1.5 T (Magnetom Avanto, Siemens). In addition to T2-
weighted and contrast-enhanced T1-weighted (ce-T1-w) data, DWI sequences
in axial and coronal plane (b = 50,500.1000) were acquired. Two reviewers
separately evaluated i) DWI, ii) ce-T1-w MRC as well as iii) DWI and ce-T1-w
MRC concerning lesions (1=none,2=one/continuous lesion (s), 3=multiple,
discontinuous lesions). Furthermore, bow el distension (1=good, 2=moderate,
3=poor) and preferred b-value were assessed. Colonoscopy (up to 48 hours
afterwards) including biopsies served as reference standard.
Results
Depiction of inflammatory lesions significantly increased with DWI
compared to T1-w MRC alone (sensiti vity/specificity 78.4%/100% vs.
95.2%/100%, respectively, compared to colonoscopy/histopathology,
p < 0.001). In six patients, lesions were only detected by DWI, in another six
patients DWI detected additional lesions. Kappa values for the two readers
were excellent (k=0.92-0.96). A combination of b=500 and 1000 was preferred
for DWI.
Conclusion
DWI of the bowel shows inflammatory lesions with high accuracy
and proved to show lesions that were not seen with ce-T1-w imaging.
Therefore, DWI seems to be able to replace, in any case complement ce-T1-w
MRC.
B-0976 14:36
MR enterocolonography: feasibility study
L. Tkali; Rijeka/HR (
[email protected])
Purpose: To evaluate feasibility of magnetic resonance enterocolonography
(MREC) in patients with Crohn's disease.
Methods
and Materials: We prospectively enrolled 108 consecutive patients,
65 men and 43 women diagnosed with Crohn's disease, mean age 41 ±14
years (age range, 17 - 68 years). After bowel cleansing patients ingested
1000 ml of the solution containing 0.5% of mannitol and 0.5% of milled carob
prior to examination. Patients were examined in prone position and warm tap
water enema was administered. HASTE, trueFISP, and VIBE sequences were
acquired. Six bowel segments were independently analysed by two
experienced radiologists. Bowel distension was assessed as poor, suboptimal
but diagnostic, and excellent by consent.
Results
Excellent large bowel distension was acquired in 93%, 94%, and 97%
of patients for ascending/transverse colon, descending/sigmoid colon, and
anorectal segment, respectively. Ileocecal and ileal distension was excellent in
82%, and 88% of examinees. Jejunal distension was excellent in 46%,
suboptimal but diagnostic in 43%, and poor in 11% of examinees. There was
no significant correlation between gender, age or body mass index (BMI), and
bowel distension. Four patients vomited (4%), and 24 examinees (22%) had
more than three stools during the oral ingestion of contrast. Significant
complications were not detected.
Conclusion
MREC is feasible. Optimal colonic, ileocecal, and ileal distension,
fair overview of the jejunal loops, good patient's acceptance, and lack of
radiation burden makes it promising diagnostic tool in diagnosis and follow-up
of patients with Crohn's disease.
B-0977 14:45
CT enterography: comparison of dose-reduced CT with hybrid iterative
reconstruction and routine-dose CT with filtered back projection for the
evaluation of sigmoid diverticulitis
A. Laqmani
1, S. Veldhoen2, S. Dulz1, F.O. Henes1, T. Derlin1, F. Wassenberg1,
H.D. Nagel3, G. Adam1, M. Regier1; 1Hamburg/DE, 2 Würzburg/DE,
3Buchholz/DE (
[email protected])
Purpose: To assess image quality of dose-reduced CT enterography (CTE)
reconstructed with hybrid iterative reconstruction (HIR) and filtered back-
projection (FBP) to routine-dose examinations reconstructed with FBP in
patients with suspected sigmoid diverticulitis (SD).
Methods
and Materials: 30 patients with suspected SD underwent contrast-
enhanced dose-reduced CTE (Brilliance iCT, tube voltage;120 kVp; mean
CTDIvol: 9.9 mGy; mean DLP: 523.4 mGy*cm; mean BMI: 29). 30 patients,
who had undergone routine-dose CTE (tube voltage;120 kVp; mean CTDIvol:
15.6 mGy; mean DLP: 852.7 mGy*cm; mean BMI: 30.5) served as reference.
S347
BA C D E F G
Monday
Routine-dose CTE images were reconstructed with FBP, dose-reduced CTE
images were reconstructed with FBP and the HIR iDose (Philips Healthcare)
using two strengths (iDose4 and 6). Four independent radiologists evaluated
image quality (1 [worst] to 5 [best]) including findings of SD. Objective image
noise (OIN) was recorded, CNR was calculated. Statistical analysis was
performed using t-test, random intercept model and ICC.
Results
In dose-reduced CTE, CTDIvol could be reduced up to 37% in
comparison to routine-dose CTE (p < 0.05). HIR reduced the OIN in dose-
reduced CTE of up to 58% compared to FBP. The lowest scores of subjective
image quality were reached in dose-reduced CTE with FBP (2.7). Dose-
reduced CTE with iDose4 was determined to be of equivalent image quality as
routine-dose CTE with FBP (Scores: 4 vs. 4.3, respectively). Interobserver
agreement was excellent (ICC: 0.91; p < 0.05).
Conclusion
HIR reduces image noise and improves image quality in dose-
reduced CTE, thus allowing for a dose reduction of 37% in CTE with
comparable image quality as routine-dose CTE.
B-0978 14:54
Submilisievert ultralow-dose CT colonography: comparison of filtered
back projection and model-based iterative reconstruction technique
L. Lambert, J. Daneš, J. Jahoda, J. Ho ejš; Prague/CZ
(
[email protected])
Purpose: To evaluate diagnostic acceptability of ultralow-dose CT
colonography.
Methods
and Materials: Sixteen patients underwent CT colonography with
standard protocol in supine position and ultralow-dose protocol in prone
position. Supine datasets were reconstructed both with filtered back projection
and advanced model-based iterative reconstruction technique. Two
radiologists with experience in reading CT colonography independently
evaluated 96 colonic segments in endoluminal view and axial thin sections.
Diagnostic acceptability, colonic distension, smoothness of colonic wall,
sharpness of colonic wall delineation, perceived image noise were rated on a
five-point scale.
Results
All distended segments were rated evaluable in standard dose and
ultralow-dose series reconstructed with iterative reconstruction technique,
whereas 61% segments were rated inevaluable in ultralow-dose series where
filtered back projection was used with worst ratings in the rectum and the
sigmoid colon. The mean radiation dose was 0.42 mSv resp. 5.48 mSv in
prone resp. supine scans.
Conclusion
Submilisievert CT colonography renders acceptable images
when advanced model-based iterative reconstrution technique is used. Further
investigations of larger scale need to be done to clarify, whether such a low-
radiation dose would influence the detection of polyps.
B-0979 15:03
Low-dose CT scans of subjects smuggling illicit concealed packages at
the UK border: a liquid situation
S. Gwyther1, A. Thompson2, L. McLennan3, D. Hillier3; 1Redhill/UK,
2Crawley/UK, 3Horley/UK (
[email protected])
Purpose: To identify subjects who have concealed illicit drugs at the UK
border. Such drugs have typically been swallowed in the solid powder form
concealed in packages such as condoms which can usually be detected by
plain abdominal radiographs (AXR). Re cently packages containing concealed
illicit drugs in the liquid form have b een encountered which are extremely
difficult to detect using AXR. Very low-dose CT scans (VLDCT) were
performed on subjects suspected of smuggling drugs in this form.
Methods
and Materials: The UK Border Agency (UKBA) provided solid and
liquid packages containing cocaine which had been recovered from subjects
attempting to smuggle them into the UK. An improvised phantom was
constructed to act as a virtual colon containing the solid and liquid packages
which were imaged using AXR MRI and VLDCT.
Results
AXR identified solid packages as regular well-defined opacities
though liquid packages were very difficult to identify using the phantom. MRI
was of no benefit. VLDCT detected solid and liquid packages with ease despite
liquid packages having irregular borders and contained air. 10 subjects
considered suspicious for smuggling illicit concealed drugs by UKBA
underwent VLDCT. 2 demonstrated solid packages 1 liquid packages 1 was a
false positive the remainder negative . All positive cases showed similar
appearances to those in the phantom.
Conclusion
This is the first report using VLDCT to detect concealed
packages in the liquid form. VLDCT reliably detects illicit concealed packages
in both the solid and liquid form with ease whilst imparting a low radiation dose.
B-0980 15:12
Right colonic diverticulitis: clinical and CT characteristics in a large
series of Caucasian patients
L. Valbousquet Schneider
1, F.-X. Arnaud2, E. Peroux1, J. Potet2, M. Zins3;
1Saint Mandé/FR, 2Clamart/FR, 3Paris/FR (
[email protected])
Purpose: To assess the clinical and CT-scan characteristics of right colonic
diverticulitis (RCD) in a large, monoc entric series of Caucasian patients in
comparison with left colonic diverticulitis (LCD).
Methods
and Materials: Two radiologists blinded to clinical information
reviewed CT-scans of 30 consecutive patients with a final diagnosis of RCD
and 70 consecutives patients with a final diagnosis of LCD, performed in our
institution between July 2005 and February 2013 and between May 2010 and
February 2013, respectively. Clinical features, CT-scan characteristics, type of
treatment and follow-up were collected in all cases (n=100). Final diagnosis
was established by an expert panel formed by 2 gastrointestinal surgeons and
a gastrointestinal radiologist, with full access to clinical, laboratory, radiologic,
pathologic and surgical findings, including a follow-up of at least 6 months.
Results
The median age was lower in RCD than in LCD patients (48 versus
64 years old, p 180°) and was more common in LCD compared to RCD (80%
versus 33.3%, p < 0.001). CT signs of severity were less frequent in RCD
compared to LCD; pericolonic abscess (3.3% versus 17.1%, p=0.06), detection
of peritoneal free air (3.3% versus 18.6%, p=0.06). RCD were associated with
less clinical complication (6.7% versus 25.7%, p=0.03), necessitating less
emergency surgery (0% versus 2.9%, p=0.10) and had a lower recurrence rate
compared to LCD (16.7% versus 34.3%, p=0.07).
Conclusion
Compared to LCD, RCD occurs in younger patients with a lower
risk of complication or recurrence. An inflamed diverticulum is a more frequent
finding in RCD.
B-0981 15:21
Technical feasibility and interobserver variability of elastosonography in
the assessment of pathological bowel tracts
A. Colleoni
1, L. Romanini1, V. Cantisani2, P. Ricci2, F. Calliada3, M. Dal Corso1,
L. Grazioli1, R. Maroldi1; 1Brescia/IT, 2Rome/IT, 3Pavia/IT
(
[email protected])
Purpose: To investigate the feasibility of elastosonography (USE) and the
inter-observer variability in the assessment of pathological bowel loops as
compared with B-mode US (US).
Methods
and Materials: We examined prospectively 41 consecutive patients
with at least one thicked bowel loop. US and USE were performed by one
expert Abdominal Radiologist with a GE E9. Images acquired by the operator
were then evaluated by two other blinded radiologists, separately. Statistical
analysis were performed with Cohen's K and Yates chi square tests. We
considered: layering and echogenicity of bowel wall on B-Mode images; wall
layering, definition of wall and peripheral tissues boundaries, and the rectus
abdomins muscle pattern (as reference) on USE images.
Results
46 pathological loops were examined: 38 at 5 MHz, 36 at 7.5 MHz
and 31 with both frequencies. Overall 74 evaluations were performed; in all out
of 10/74 (13.5%) an adequate elastogram was obtained. For the first reader,
the agreement about bowel wall stratification between US and USE was fair,
without statistically significant diffe rences between the two frequencies
(p=0.56). Among the three readers, a moderate agreement was found on B-
Mode images about bowel wall layering and echogenicity. On USE images
Cohen's test provided a moderate agreement for layering; a slight agreement,
instead, was found for bowel wall and peripheral tissues boundaries, and in the
evaluation of rectus abdominis muscle.
Conclusion
USE evaluation of pathological bowel walls is feasible. A
moderate agreement among the three Radiologists was found. Further studies
will define the clinical role of this tool.
S348
BA C D E F G
Monday
14:00 - 15:30 Room F1
Oncologic Imaging
SS 1816
Tumour characterisation: methodological
aspects and clinical prospects
Moderators:
L.S. Fournier; Paris/FR
N.N.
B-0982 14:00
Multiparametric quantitative MRI in neurooncology: impact of single
parameters on overall accuracy
M. Dietzel1, B. Volbers1, P.A.T. Baltzer2, S. Kloska1, T. Struffert1,
T. Engelhorn1, S. Lettmaier1, R. Fietkau1, A. Dörfler1; 1Erlangen/DE,
2Vienna/AT
Purpose: Multiparametric quantitative MRI provides a large range of measures
for tissue characterisation. Interestingly, knowledge on the additional
diagnostic-value of each single parameter and knowledge on the overall
diagnostic accuracy of all parameters in combination is still limited.
Methods
and Materials: Patients were investigated using a clinical MR-
scanner (Siemens Magentom Aera, B 0=1.5T) applying DTI (diffusion tensor
imaging), DWI (diffusion weighted imaging) as well as DCE sequences
(dynamic contrast enhanced; after i.v. injection of 6 ml Gadovist @2 ml/s). For
multiparametric quantitative assessment of the tumors ktrans, k ep, V e (DCE:
Tofts-Modell), ADC (DWI) und FA (DTI) were calculated using appropriate
post-processing software. Clinical follow-up as well as histopathology served
as reference-standard (fifteen malignant and non-malignant brain tumors). All
quantitative MR-parameters were analysed by means of uni- and multivarate
statistics and were correlated with the reference-standard (malignant vs. non-
malignant: AUC- and ROC-analysis, logistic regression with feature selection).
This approach allowed exploring significant and independent but also
redundant MR-parameters; furthermore, overall-accuracy of the protocol could
be addressed to stratify the reference-standard.
Results
In univariate analysis FA reached highest accuracy (AUC=0.92). K
ep
and ADC did not provide additional diagn ostic value in multivariate analysis
(P < 0.05). Yet Ktrans, Ve and FA were identified as significant and independent
predictors of malignant brain tumours (r2=1; AUC=1).
Conclusion
Multiparametric magnetic resonance imaging enabled accurate
quantitative assessment of brain tumours. Ho wever, our analysis identified also
redundant information without additional diagnostic-value. This approach might
help to translate multiparametric imaging parameters into diagnostic
information and thus could facilitate its application in clinical practice.
B-0983 14:09
7 Tesla MRI goes clinical: imaging Glioblastoma multiforme at 7T versus
3 T
L. Umutlu, A. Fischer, J. Hense, T.C. Lauenstein, M. Forsting, M. Ladd,
O. Kraff, M. Schlamann; Essen/DE (
[email protected])
Purpose: Aim of this trial was to compare the delineation of glioblastoma
multiforme on susceptibility-weighted (SWI) and contrast-enhanced MPRAGE
MRI utilising 3 T and 7T MRI.
Methods
and Materials: 5 subjects were examined on a 3 T (Magnetom
Skyra) and a 7T whole-body MR system (Magnetom 7T) utilising 32-channel
head-coils (Siemens Healthcare). Minimum intensity projections (MinIP) of a 3
T SWI sequence (voxel size 0.7x0.8x2.6 mm3) were compared to 7 T SWI
MinIPs (voxel size = 0.25x0.25x1.0 mm3). A T 1-w 3D MPRAGE at 3 T (voxel
size = 0.5x1.0x1.0 mm3) after the application of Gadobutrol (Bayer Healthcare)
was compared to 7 T MPRAGE MRI (voxel size = 0.7 x 0.7 x 0.7 mm3). Two
radiologists assessed the delineation of the (1) tumor in T1w MRI, (2)
microvasculature in SWI imaging and (3) impairment due to artifacts utilising a
5-point scale (5= excellent to 1= non-diagnostic).
Results
Visual analysis revealed an equivalently excellent delineation of
tumor extent and morphology for MPRAGE imaging at both field strengths
(MPRAGE 3 T 4.78 vs MPRAGE 7T 4.80). 7T SWI demonstrated its superiority
in vessel assessment, yielding a significant improvement in the delineation of
tumor-associated microvasculature (SWI 3 T 3.79 vs SWI 7T 4.85). Evaluation
of artifacts showed slightly stronger image impairment for 7T imaging (mean3 T
4.79 vs mean7T 4.34).
Conclusion
Both field strengths provide high-quality assessment of tumor
extent and morphology, with 7T SWI demonstrating its superiority in the
assessment of microvasculature. Hence, an increase of the field strength to 7T
may help to better understand tumor-associated neoangionesis.
B-0984 14:18
Histogram analysis of apparent diffusion coefficient map of diffusion-
weighted MR imaging in endometrial cancer: a preliminary correlation
study with histological grade
S. Woo, J. Cho, S. Kim, S. Kim; Seoul/KR (
[email protected])
Purpose: To explore the role of histogram analysis of ADC maps based on
entire tumour volume in determining the grade of endometrial cancer.
Methods
and Materials: This study was IRB-approved with waiver of informed
consent. 33 patients with endometrial cancer underwent diffusion-weighted MR
imaging (b=0, 600, 1000 s/mm2), and corresponding ADC maps were acquired.
ROIs were drawn on all slices of the ADC map in which the tumour was
visualised including areas of necrosis to derive volume-based histographic
ADC data. Histogram parameters (5-95 th percentiles, mean, standard
deviation, skewness, kurtosis) were corr elated with histological grade using
one-way ANOVA with Tukey-Kramer test for post hoc comparisons, and were
compared between high (grade 3) and low (grades 1/2) grade using Student t-
test. ROC curve analysis was performed to determine the optimum threshold
value for each parameter, and their corresponding sensitivity and specificity.
Results
The standard deviation, quartile, 75
th, 90 th and 95 th percentiles of
ADC showed significant differences between grades (P 0.03 for all) and
between high- and low-grades (P 0.024 for all). There was no significant
correlation between tumour grade and other parameter. ROC curve analysis
yielded sensitivities/sp ecificities of 75%/96%, 62.5%/92%, 100%/52%,
100%/72%, and 100%/88%, using standard deviation, quartile, 75 th, 90 th and
95th percentiles for determining high grade with corresponding AUCs of 0.787,
0.792, 0.765, 0.880, and 0.925, respectively.
Conclusion
Histogram analysis of ADC maps based on entire tumour volume
can be useful for predicting the histological grade of endometrial cancer. The
90th and 95 th percentiles of ADC were the most promising parameters for
differentiating high- from low-grade.
B-0985 14:27
Tumour-to-liver ratio is superior to a SUVmax cut-off for detection of
malignant peripheral nerve sheath tumours in neurofibromatosis type 1
J. Salamon, P. Bannas, J.D. Busch, J. Herrmann, G. Adam, V.F. Mautner,
T. Derlin; Hamburg/DE (
[email protected])
Purpose: For evaluation of malignant transformation of peripheral nerve
sheath tumours (MPNSTs) in patients with neurofibromatosis Type 1 (NF1), a
standard SUV cut-off value is used without accounting for the interindividual
variability, leading to a substantial number of false-positive results. The aim of
this study was to evaluate the potential usefulness of normalisation of
intratumoural tracer uptake in FDG PET/CT to a reference tissue as compared
to a cut-off SUV
max to reduce false negative results.
Methods
and Materials: 49 NF1 patients underwent 18F-FDG PET/CT.
Intralesional 18F-FDG uptake was analysed by assessment of the maximum
standardised uptake value (SUV). Tracer uptake was normalised to different
Reference
tissues. To assess the diagnostic performance of normalised tracer
uptake for detection of malignancy in PNSTs as compared to a standard
SUV
max cut-off of 3.5, ROC analyses were performed. Histopathology, clinical
and radiological follow-up served as reference standards.
Results
Using a SUV
max cut-off value of 35 demonstrated a sensitivity of
100% and a specificity of 79.8%. Norma lisation of tracer uptake to liver tissue
resulted in a significant improvement (p=0.013, McNemar test), demonstrating
a specificity of 90.3%, maintaining a s ensitivity of 100%. A cut-off value of 2.6
using the tumour-to-liver ratio was the optimum threshold for tumour
differentiation (AUC=0.9735).
Conclusion
Quantitative 18 F-FDG PET/CT may identify malignant change in
plexiform neurofibromas with high accuracy. Increased accuracy could be
obtained by calculating a tumour-to-liver ratio, offering significantly higher
specificity than the standard SUV
max cut-off. We recommend using a tumour-to-
liver ratio cut-off value of 2.6 for detection of malignancy.
B-0986 14:36
Dynamic features of MR-guided histologically proven lesions:
comparison 1.5 T vs 3 T MRI
A. Malich
1, J. Dvorak1, U. Teichgräber2, A. Kott1, J. Feger1; 1Nordhausen/DE,
2Jena/DE (
[email protected])
Purpose: Current study compared dynamic features of only MR-visible lesions
at 1.5 T vs 3 T according to histopathology outcome (MR-guided biopsy).
Methods
and Materials: 425 MR-guided biopsies were recommended due to
diagnostic breast-MRI from 2007 to 2013 at our departement. Dynamic
characteristics (initial signal incr ease; wash out, enhancement-shape, type,
blooming, adjacent vessel) were matched to histopathology. 354 and 71
interventions were performed at 1.5 T and 3 T (Philips Achiva and Ingenia).
Mean lesion size was 6 and 7 mm, respectively. Diagnostic study protocol was
similar.
S349
BA C D E F G
Monday
Results
In 285/354 and in 62/71 cases, biopsy was finished successfully at
1.5 T and 3 T, respectively (19.5% vs. 9.8%). 50.8%/42.2% of recommended
biopsies were proven as B2 at 1.5 T/3 T, respectively. Rapid initial peak signal
increase occurred in 81.7%/80.0% vs. 88.9%/88.2% at benign/malignant
lesions at 1.5 T/3 T. Wash out curve was observed at 61.7%/56.7% of benign
lesions and 72.2%/76.5% of malignant lesions at 1.5 T/3 T. Blooming is
significantly more common at malignant and premalignant lesions, but also at
3 T vs. 1.5 T: benign: 1.5 T/3 T: 28.9%/66.7%; in situ: 49%/64.7%; invasive
malignant: 44.4%/82.3%. Ring enhancement is more common in malignant
lesions and slightly more common at 3 T: Benign 1.5 T/3 T: 17.2%/20.0%; in
situ: 11.8%/23.5%; malignant: 27.8/29.4%. Adjacent vessel sign is significantly
more often visible at 3 T/1.5 T: benign lesions: 76.5%/36.1%; malignant lesions
88.2%/50.0%.
Conclusion
Dynamic features differ dignity dependent suggesting a
malignant lesion to be associated with ring enhancement, blooming, adjacent
vessel. Sign-occurance dependends on magnetic field-strength. MR-guided
biopsies at 3 T are safe, abortion rate is significantly lower and verification of
B3b/B5a/B5b is significantly more common at 3 T vs. 1.5 T.
B-0987 14:45
Modification in abdominal fat distribution after aromatase inhibitor in
breast cancer patients using CT volumetry
S. Battisti1, D.M.A. Vaccaro1, R.C. Semelka2, B. Beomonte Zobel1; 1Rome/IT,
2Chapel Hill, NC/US (
[email protected])
Purpose: To describe modification of subcutaneous adipose tissue (SAT) and
visceral adipose tissue (VAT) distributions in breast cancer patients following
therapy with aromatase inhibitors (AI) using CT volumetric measurement of
abdominal body fat distribution.
Methods
and Materials: 64 consecutive patients (mean age 55.8 ±11.7 years;
age range 36-77) with a history of radical mastectomy, who were receiving
adjuvant AI therapy (anastrozolo n=33; letrozolo n=31) were included. Patients
were evaluated with CT before and after AI therapy, with imaging follow-up of
4.3±2.2 years. Abdominal fat distribution analysis was automatically calculated
using a workstation that obtained total abdominal adipose tissue (TAAT) area
(mm
3). SAT was manually segmented and VAT was determined as TAAT-SAT.
Percentages were calculated for change of TAAT, VAT and SAT. VAT/SAT
ratio was calculated. Student-T-test was used to compare the variables.
Results
Percentage of TAAT after AI therapy: mean increase of 9.1% from
ase-line 16280.3 ±6953.3 mm3 (average and standard deviation SD) to
17763.6±6850.8 mm3. Two groups of patients were observed: those with an
increase in TAAT (group A, 43 patients), those with a decrease (group B, 21
patients). Modification of VAT/SAT ratio was observed (1.38-1.69) in all
subjects, reflecting a relatively increased volume of VAT (mean 18%) and
slight mean reduction of SAT (mean 1.9%).
Conclusion
Therapy with AI in breast cancer patients was accompanied with
a change in fat distribution to relatively greater VAT/SAT ratio in all the
patients, regardless of whether they gained or lost weight after therapy. Since
this pattern of fat distribution is associated with the metabolic syndrome,
attention must be paid to these clinical manifestations in patients during their
follow-up management.
B-0988 14:54
Assessing pathologic response in colorectal liver metastases undergoing
preoperative chemotherapy: a comparison of CT texture analysis with
RECIST and tumour volumetry
S.-X. Rao
1, D.M. Lambregts2, F. Albarello3, M.H. Martens2, L.A. Heijnen2,
R. Schnerr2, M.-S. Zeng4, G.L. Beets2, R.G.H. Beets-Tan2; 1Shanghai/CN,
Maastricht//NL, 2Maastricht/NL, 3Ferrara/IT, Maastricht/NL, 4Shanghai/CN
(
[email protected])
Purpose: Aim was to compare the potential of CT texture analysis, CT tumour
volumetry and unidimensional (RECIST) measurements for response
assessment of colorectal liver metastases undergoing preoperative
chemotherapy.
Methods
and Materials: Twenty-two patients with known colorectal liver
metastases who underwent CT both before and after chemotherapy were
included. Texture analysis of the total volume of all metastatic lesions was
performed on portal phase CT-images. Mean intensity (M), entropy (E) and
uniformity (U) were derived without filtration (0.0) and with different filters
corresponding to fine (0.5), medium (1.5), and coarse (2.5) textures.
Additionally, total tumour volume ( mm3) and largest lesion diameter (according
to RECIST 1.1) were determined. Pre-, post-chemotherapy and relative
change rates ( ) of the different texture parameters, volume and RECIST-
diameters were compared between good responders (n=8, defined as
histological tumour regression grade (TRG) of 1-2) and poor responders (n=14;
TRG 3-5).
Results
For CT texture analyses, the post-treatment E0.0, U0.0 as well as the
E0.0, E0.5, E1.5, U0.5 and U1.5 were significantly different between good
and poor responders (p=0.01-0.04). Pre-chemotherapy texture parameters
were not significantly different (p > 0.05). The volume of good responders was
significantly different from poor responders (p=0.048).There were no
differences between good and poor responders for mean diameters according
to RECIST.
Conclusion
Unidimensional tumour measurements according to RECIST are
not helpful to assess pathologic response after treatment. Tumour volumetry
and in particular CT texture analyses withhold promise to discriminate between
poor and good responders after chemotherapy.
B-0989 15:03
Texture analysis on pre-treatment contrast-enhanced CT of colorectal
cancer liver metastases: prediction of response to bevacizumab-
containing chemotherapy according to Choi's criteria
U. Navarro, M. Ravanelli, C. Barbieri, A. Colleoni, A. Berruti, R. Maroldi;
Brescia/IT (
[email protected])
Purpose: To test the correlation between tumour heterogeneity measured on
pre-treatment contrast-enhanced CT (CECT) and response to bevacizumab-
containing therapy assessed by Choi's criteria in colorectal cancer liver
metastases (CRC-LM). Recent studies suggest that response to anti-
angiogenetic drugs defined by Choi's criteria better correlates with prognosis
than RECIST-based evaluation.
Methods
and Materials: Fifty-seven CRC-LM in 25 patients treated with
bevacizumab-containing therapy were included. Uniformity (U) of fine texture
was quantified for each lesion on pre-treatment CECT (portal phase).
Treatment response was assessed by Choi's criteria at lesion-level.
Multivariate logistic regression was used to test the predictive value of U and
other lesion- and patient-related variables.
Results
34 CRC-LM responded to therapy (partially or completely), 23
remained stable or progressed. U was signi ficantly lower in responders than in
non-responders (p < 0.0001). Multivariate analysis (including: U, lesion size,
lesion CT density, scheme of bevacizumab-associated chemotherapy,
chemotherapy line number) demonstrated that U was the unique predictor of
treatment response. Dividing U into tertiles, lesions belonging to 1 st tertile had
12-folds (p0.03) and 71-folds (p0.0003) higher probability of response
compared to lesions belonging to 2
nd and 3 rd tertile, respectively. Ninety-five
percent, 39% and 21% of lesions belonging respectively to 1 st, 2 nd and 3 rd
tertile responded to therapy (p < 0.0001, p trend < 0.0001).
Conclusion
Heterogeneity of CRC-LM quantified on CECT correlates with
probability of response to bevacizumab-containing therapy, as assessed by
Choi's criteria, and could help to stratify patients undergoing chemotherapy.
B-0990 15:12
Texture analysis on pre-treatment contrast-enhanced CT of colorectal
cancer liver metastases: prediction of response to bevacizumab-
containing chemotherapy according to RECIST 1.1
M. Ravanelli, A. Colleoni, D. Farina, R. Maroldi; Brescia/IT
(
[email protected])
Purpose: To test whether texture analysis (TA) on pre-treatment contrast-
enhanced CT (CECT) has the potential to predict the response of colorectal
cancer liver metastases (CRC-LM) to bevacizumab-containing therapy.
Methods
and Materials: Fifty-seven CRC-LM in 25 patients treated with
bevacizumab-containing therapy were included. Fine texture of each lesion
was extracted and quantified on pre-treatment CECT images (portal phase),
resulting in a parameter (uniformity, U) describing tumour heterogeneity.
Treatment response was assessed by RECIST1.1 at lesion-level. Interobserver
variability of U was measured using Bland-Altman method. The predictive
value of U and other lesion- and patient-related variables was tested by
multivariate logistic regression.
Results
Twenty-two lesions showed a response (partial/complete); absence
of response was observed in 35 lesions. Interobserver variability of U was low.
U was significantly lower in responders than in non-responders (p > 0.0001).
Multivariate analysis (U, lesion size, lesion CT density, bevacizumab-
associated chemotherapy scheme, chemotherapy line number) demonstrated
that U was the unique predictor of treatment response. Dividing U into tertiles,
lesions belonging to 1
st tertile had a 13-folds (p0.02) and 39-folds (p0.001)
higher probability of response compared to lesions belonging to 2 nd and 3 rd
tertile, respectively. Lesion CT density wa s close to a marginally significant
level (p0.06), suggesting that lesions with higher CECT enhancement tend to
better respond to therapy.
Conclusion
Tumour heterogeneity quantified by TA on CECT allowed to
predict response to bevacizumab-containing therapy in CRC-LM, according to
RECIST1.1.
S350
BA C D E F G
Monday
B-0991 15:21
Texture analysis as a predictive and prognostic biomarker of tumoural
response to neoadjuvant chemoradiotherapy in rectal cancer patients
studied with 3 T MR
C. De Cecco
1, B. Ganeshan2, M. Ciolina1, M. Rengo1, D. Bellini1, A. Laghi1;
1Latina/IT, 2Brighton/UK (
[email protected])
Purpose: To determine if T2-weighted MR image texture features of rectal
cancer can predict tumoral response in patients treated with neoadjuvant
chemoradiotherapy.
Methods
and Materials: Fifteen consecutive patients underwent pre- and
post-treatment (6-8 weeks) MRI performed at 3 T. Treatment protocol
consisted of neoadjuvant chemoradiotherapy with oxaliplatin and 5-
Fluorouracile. Texture was assessed within unenhanced axial T2-weigthed
images by manually delineating a ROI around the tumor outline for the largest
cross-sectional area. Heterogeneity within this ROI was quantified using
TexRAD, a commercially available researc h software algorithm that selectively
filters and extracts texture at different anatomic scales (features of 2-6 mm
radius representing fine to coarse scales) with quantification of kurtosis
(pointedness of distribution or histogra m) and mean value of positive pixels
(MPP). Surgical specimens were the gold standard.
Results
Six patients showed complete pathological response (cPR) and 4
patients partial response (PR). Five patients were classified as non-responders
(NR). A significant difference in basel ine kurtosis was observed between cPR
in comparison with PR+NR (p=.01). After treatment, a significant difference in
kurtosis and MPP was observed between cPR and PR+NR (p=.045) and
between cPR+PR and NR (p=.041) respectively. Relative change in kurtosis
and MPP acted as prognostic biomarkers between cPR and PR+NR (p=0.034
and p=0.045 respectively) in addition to between cPR+PR and NR (MPP,
p=0.041).
Conclusion
Texture parameters derived from T2w images of rectal cancer
have the potential to act as a predictive and prognostic biomarker of tumoral
response to neoadjuvant chemoradiotherapy.
14:00 - 15:30 Room F2
Breast
SS 1802
PEM, PET and novel MRI techniques
Moderators:
A. Selim; Cairo/EG
P. Zamecnik; Nijmegen/NL
B-0992 14:00
High specificity and even high sensitivity of positron emission
mammography (PEM) in diagnosis of breast cancer
F.H.H. Müller
1, A.G. Müller1, M. Hentschel2, J. Farahati3; 1Ludwigshafen/DE,
2Berne/CH, 3Dorsten/DE (
[email protected])
Purpose: What will cause the diagnostic performance of PEM, a HR-PET with
intrinsic resolution of 1.6 mm in detection of breast cancer (B-Ca)?
Methods
and Materials: PEM was performed in 122 lesions with suspicious
breast lesions 90 min after i.v. application of 3.5 MBq F-18-FDG per KG body
weight. A ROI marked the target lesion, measured by the maximum PEM
uptake value (PUVmax) and was correlated with a corresponding non-target
ROI in the contra lateral healthy breast determining the target/non-target ratio.
Two independent readers analysed images of all 122 lesions and compared
the results to histopathology (11 PEM-Biopsies/8 Breast-Cancers) later. The
group analyses for all malignant, benign, corresponding non-target lesions and
the mean target/non-target ratio were calculated by paired Student t-Test.
Results
22 out of 122 lesions were malignant. Mean of PUVmax was
measured 4.3 ±2.7 in malignant lesions and 1.2 ±0.4 for the contra-lateral
healthy breast (p=0.001). The mean target/non-target ratio in patients with B-
Ca of 3.7 ±1.5 was significantly higher compared to benign lesions 1.2 ±0.35
(p=0.001). Considering a PUVmax > 1.9, PEM was true-positive in all 22
cancers resulting in a sensitivity of 100%, specificity of 97%, PPV of 88% and
NPV of 100%. Detecting of B-Ca by PEM was at it´s best observed with a
PUVmax cut-off level of > 1.9 combined with a target/non-target ratio of > 1.4.
Conclusion
PEM detects Breast Cancer with high sensitivity and high
specificity. The higher specificity causes a lower rate of biopsies, surgery,
chemotherapy and costs, therefore a evidence based study will start in
Germany.
B-0993 14:09
Correlation of MIB1 proliferation index with quantitative PET and 3 Tesla
MRI-derived imaging biomarkers
K. Pinker-Domenig, P.A.T. Baltzer, H.F. Magometschnigg, G. Wengert,
M. Bernathova, W. Bogner, G. Karanikas, Z. Bago-Horvath, T.H. Helbich;
Vienna/AT (
[email protected])
Purpose: In recent years, proliferative markers have been broadly evaluated
as prognostic and predictive factors for early stage breast cancer (BC) patients
and studies have shown a statistically significant correlation with clinical
outcome. In clinical practice, proliferation in BC is often assessed through
immunohistochemistry (IHC) measurement of MIB1 expression. This study
aimed to determine possible correlations between quantitative biomarkers
obtained from PET-CT and 3 T MRI and the MIB1 proliferation index.
Methods
and Materials: In this IRB-approved prospective study, 249 patients
with primary BC were included. Before undergoing surgery, all patients
underwent 3 T-MRI including ADC measurements of BC lesions. Further, Cho-
SNR was measured by 1H-MRSI in 62 patients. 134 patients underwent
18 FDG breast PET-CT and maximum standardised uptake value (SUVmax) of
tumours was calculated. Cell proliferation of tumours was assessed through
standard immunohistochemistry with MIB1. Proliferative activity derived from
MIB1 was categorised into: 30 high. Approp riate statistical tests were used to
test for any association among SUVmax, ADC, SNR and MIB1.
Results
A significant association between MIB1 of BC and SUVmax was
identified (p < 0.001). There was a significant difference of SUVmax for
tumours with high proliferation compared to medium (p < 0.001) and low
(p < 0.001) proliferation. There was no significant correlation of MIB1 with both
ADC (p=0.424) and Cho-SNR (p=0.082).
Conclusion
In primary BC, a correlation of MIB proliferation index was found
for the imaging biomarker SUVmax with 18 FDG breast PET-CT, but not for
quantitative imaging biomarkers obtained from 3 Tesla MRI.
B-0994 14:18
The role of FUSION between MRI and PET-CT as preoperative staging
M. Páramo, R. Zalazar, A. Elizalde, L.J. Pina Insausti, C. Vigil, M. Hernández,
M. Rodríguez-Fraile; Pamplona/ES (
[email protected])
Purpose: The objective of our study was to compare the sensitivity (SE) and
specificity (SP) of preoperative MRI, PET-CT and FUSION between both
techniques.
Methods
and Materials: 31 consecutive patients with histologically proven
invasive breast cancer and both preoperative MRI and PET-CT were selected.
All the PET-CT studies were performed using the breast MRI coil with the
patient in prone position. We retrospectively evaluated the MRI and PET-CT
images blinded to the final diagnosis. The FUSION between MRI and PET-CT
was performed using the software TRUE-D. The FUSION images were
interpreted in agreement between 2 breast radiologists and 2 nuclear medicine
doctors. All the lesions were classified as positive (malignant) or negative for
each technique and compared with the gold standard (surgery or follow-up).
The results were collected using an excel table to calculate the sensitivity and
specificity, and the statistical significance was studied using the PEPI software.
Results
31 patients with 67 lesions were studied. Out of them, 40 lesions
were histologically malignant. The SE and SP for each technique were: MRI
97.5% and 11.1%; PET-CT 92.5% and 85.2%; FUSION 95% and 96.3%. The
comparison between MRI and FUSION showed statistically significance for SP
(11.1% vs 96.3%; p 0.05). However,
the comparison between PET-CT and FUSION showed no statistically
differences (SE: 92.5% vs 95%; SP: 85.2% vs 96.3%; p > 0.05).
Conclusion
The FUSION between MRI and PET-CT significantly increases
the specificity of preoperative MRI without decreasing the sensitivity.
B-0995 14:27
The value of DWI based on biexponential model in differential diagnosis
between benign and malignant lesions of breast
J. He, Y. Zhang, J. Cheng, Y. Hu; Henan/CN (
[email protected])
Purpose: To investigate the application value of DWI based on biexponential
signal decay modelling with extender b-fact or range in differential diagnosis of
benign and malignant lesions of breast.
Methods
and Materials: A total of 73 patients with breast tumour underwent
DWI based on the biexponential signal decay model with extended b-factor
range (eight b-factors, were 0, 20, 50, 100, 200, 400, 800, 1200 s/mm 2).
Among them, benign lesions were found in 35 cases (41 breast tumour, benign
group), while malignant lesions were found in 38 cases (39 breast tumour,
malignant group). The value of slow apparent diffusion coefficient, fast
apparent diffusion coefficient and fraction of fast ADC of lesions were
measured on Advantage Windows 4.5 workstation and these parameters were
compared if they had statistically significant differences between the benign
and malignant groups.
S351
BA C D E F G
Monday
Results
ADCslow, ADCfast and f fast were (1.24±0.40) ×10-3 mm2/s, (10.70±8.26)
×10-3 mm2/s and (15.69 ±3.88)% in benign group. While they were
(0.80±0.14)×10-3 mm2/s, (13.79 ±7.62)×10-3 mm2/s and (20.02 ±5.79)% in
malignant groups. The statistically significant differences of ADC slow and f fast
were found among the two groups with comparison, while the statistically
significant differences of ADC fast were not found among the two groups with
comparison.
Conclusion
Biexponential signal decay model of DWI with extended b-factor
range can provide significant tissue ch aracterisation parameters for differential
diagnosis between benign and malignant lesions of breast.
B-0996 14:36
Peritumoral anisotrophy of the breast cancer on diffusion tensor imaging
T.-H. Chang, H.-H. Hsu, G.-S. Huang; Taipei/TW
(
[email protected])
Purpose: Our goal is to demonstrate the anisotropic water diffusion at the
periphery of the breast cancer, and to survey the clinical implications.
Methods
and Materials: To collect breast cancer cases due to preoperative
assessment from March 2010 to July 2013, we have 22 cases who received
diffusion tensor imaging (DTI), and 13 cases were proved to be malignant. We
analyse their DTI images and correlate wi th their histopathology, including
immunohistochemical (IHC) stains.
Results
Of these 13 malignant cases, there are 1 case with lymphoma, 4
cases with in situ carcinoma, and 8 cases with invasive ductal carcinoma.
Peritumoral anisotrophy is only identi fied in invasive ductal carcinoma (7/8).
Parametric DTI ( 61, 62, 63, 61-63, FA, MD, ADC) reveals no significant
relationship with IHC stains (ER/PR/Her2/Ki67). However, there is relatively
significant finding on a Her2 type case, but it does not demonstrate peritumoral
anisotropy.
Conclusion
Normal breast tissues (ductal/glandular region) reveal low-to-
moderate anisotropy. When a breast tumor develops, it will cause
fibroglandular tissue less anisotrophy together with peritumoral anisotropy
(mass effect). DTI seems not to predict the prognosis of breast cancer due to
no significant relationship with IHC stain.
B-0997 14:45
Clinical utilisation of breast diffusion tensor MRI
N. Nissan1, M. Feinberg-Shapiro2, N. Weisenberg2, Z. Tanya2, D. Grobgeld1,
H. Degani1, E. Furman-Haran1; 1Rehovot/IL, 2Kfar Saba/IL
(
[email protected])
Purpose: To investigate breast diffusion tensor parameters under various
hormonal manipulations and to evaluate the ability of these parameters to
detect and diagnose breast cancer.
Methods
and Materials: All volunteers were scanned at 3 T using DTI and T2-
weighted protocols. Patients with breast lesions (n=106) were also scanned
using a DCE protocol. Hormonal changes were investigated (n=45) in
premenopausal women scanned four-times during menstrual-cycle, in lactating
women and in postmenopausal (HRT ±) women.
Results
DTI parameters of premenopausal healthy volunteers were highly
steady along the menstrual cycle, exhibiting low (1-2 %) within-subject
coefficient of variance, and high (0.93-0.98) intra-class correlation. Significantly
lower diffusion coefficients were found in the HRT (-) as compared with
HRT (+) or premenopausal volunteers, and in lactating volunteers as compared
with premenopausal volunteers. All breast lesions were enhanced by DCE but
varied in the dynamic features. The DTI parameters: 6 1, 61-63 and ADC were
significantly lower in the cancers than in normal tissue and benign lesions,
enabling high detection sensitivity. In heterogeneously dense and highly dense
breasts DTI detection rate was the same as DCE. However, in highly fatty
breasts technical challenges due to inhomogeneous fat-suppression, low S/N
and EPI distortions impaired DTI utility.
Conclusion
DTI has the potential to serve as a standalone method for
detecting breast cancer in patients with moderate to high-dense breasts and
when DCE is prohibited. The timing for performing breast DTI is not restricted
to a certain phase during menstruation. The modulations in diffusion
parameters due to HRT and lactation should be taken into account upon DTI
evaluation.
B-0998 14:54
Breast MR spectroscopy at 3 T in biopsy proved breast cancers: does
choline peak correlate with prognostic factors?
M. Luciani, F. Pediconi, M. Telesca, F. Vasselli, V. Casali, A. Castrignanò,
I. Carpignano, C. Catalano; Rome/IT (
[email protected])
Purpose: To evaluate the correlation between the presence of choline peak on
MR spectroscopy at 3 T and prognostic factors in patients with biopsy proved
breast cancer.
Methods
and Materials: Breast MR spectroscopy was performed at 3 T in
patients with biopsy proved malignant lesions measuring 8 mm or larger at MR
imaging. Single-voxel MR spectroscopy data were collected from a single
rectangular volume of interest that encompassed the lesion. MR spectroscopy
findings were then compared with histol ogic findings. Lesion size, histotype,
nuclear grade, receptor status (ER, PgR), and Ki67 and HER2 expression
were evaluated.
Results
102 patients with BI-RADS 6 lesions (94/102 IDC; 8/102 ILC) were
evaluated. Choline peak was detectable in 48/102 cases, it was not detectable
in 54/102. There was a statistically significant association between the choline
peak and the lesions size (p=0.005). The choline peak was significantly
associated with Ki-67 (median value 24.63 ± 21.37, p=0.003). We observed a
statististically significant association between choline peak and grade 3
(24/102 patients, 23.5%, p=0.001) and between choline peak and HER2
(p=0.04). No statistically significant association of choline peak with receptor
status (ER, PgR) and Luminal A, B1 and B2 was detected, as well as, between
choline peak and triple negative; although 66.66% of triple negative patients
with no detectable choline peak, had lesions with a large central area of
necrosis.
Conclusion
3 T breast MR spectroscopy, can be a tool to predict tumour
aggressiveness and the correlation between choline peak and prognostic
factors such as Ki67, HER2 and grading 3, may have a clinical relevance.
B-0999 15:03
Value of MR-breast elastography as an adjunct tool to MRI to diagnose
and characterise breast lesions
C.S. Balleyguier
1, A. Ben Lakhdar1, A. Dunant1, M.-C. Mathieu1, S. Delaloge1,
R. Sinkus2; 1Villejuif/FR, 2Clichy/FR (
[email protected])
Purpose: To evaluate the value of MR-Breast elastography (MRE) in
association with standard breast MRI to improve lesion analysis.
Methods
and Materials: An optimised MRE sequence covering entire breast
in 10 minutes was developed and applied on 10 healthy volunteers. 50 patients
presenting an undetermined or suspicious breast lesion (37 cancers, 13 benign
lesions) were also included in this study. All patients were examined with
standard breast MRI (T1w and T2w with fat suppression sequences, dynamic
3DFSPGR sequence with and without IV gadolinium chelates injection) and
MRE with a dedicated prototype; Morphologi cal, kinetic and visco-elastic MR
parameters (Gd, (dynamic modulus: elastici ty), Gl (loss modulus, viscosity) and
y=Gl/Gd) were correlated to pathology. Specific histological parameters
(vascular grading, fibrosis, necrosis) were analysed and correlated to visco-
elastic MR parameters.
Results
MR visco-elastic properties were strongly correlated with Bi-RADS
malignancy score and with malignant and benign status (p=0.02). Gd value
(stiffness) decreased as BI-Rads score increased. Gl parameter (Loss
modulus) was higher in malignant lesions in comparison with benign lesions,
with viscosity level statistically higher in malignant lesions (p=0.02). Ratio y
(Gl/Gd) was significantly higher in malignant lesions (p=0.002). Addition of
MRE sequence to standard breast MRI improved significantly breast MRI
sensitivity (78 to 91 %) without reduction in specificity. MR viscoelastic
parameters were not significantly linked to specific histological parameters.
Conclusion
MRE may be an adjunct new functional tool to better discriminate
undetermined or suspicious enhancing lesions on standard breast MRI.
Viscoelastic MR properties may be linked to BI-Rads categories.
B-1000 15:12
Magnetic resonance electrical impedance mammography: a new
approach to breast cancer imaging
M. Kallergi
1, J.J. Heine2, E. Wollin3; 1Egaleo/GR, 2Tampa, FL/US, 3Sarasota,
FL/US (
[email protected])
Purpose: The purpose of this study was to investigate the use of magnetic
resonance electrical impedance mammography (MREIM) for breast cancer
screening. We have previously shown that breast MRI specificity could improve
by combining standard breast MR with a time varying electric field and
exploiting conductivity differences between normal and malignant breast
tissue.
Methods
and Materials: Dedicated phantoms and hardware were developed
to fit within the stabilisation paddles of a standard MR breast coil. Electrical
conductivity differences between tissue and tumour-like materials were
studied. A theoretical model was developed for the conductive properties of the
tumour-normal tissue environment within the induced magnetic field. Computer
simulations of the perturbed MR acquisition process were then generated and
compared to the experimental data.
Results
A detectable differential signal was produced in phantom areas of
higher electrical conductivity by the confluence of a frequency encode effect
that manifests as a differential signal across the "malignancy" area and a
phase encode effect that appears as a differential signal about the
"malignancy" border. The signal was generated without gadolinium contrast
injection and did not require special image reconstruction. Imaging seems
possible with an add-on apparatus "i nvisible" to the patient without
cumbersome electrode configurations. Theory and simulation agreed with the
experiment.
S352
BA C D E F G
Monday
Conclusion
Preliminary results suggest that tissue conductivity combined with
magnetic imaging properties could be the new biomarker for breast cancer.
Current work includes the development of durable and compliant phantoms
with stable electrical and mechanical prope rties to allow optimisation of the MR
sequence parameters for this technique.
Author Disclosures:
E. Wollin: Patent Holder; MREIM. Other; President, Wollin Ventures Inc.
B-1001 15:21
Quantitative imaging of breast cancer: association between receptor
status, 18 FDG-PET and 3 Tesla MRI using DWI and 3D-MR-spectroscopy
K. Pinker-Domenig, H.F. Magometschnigg, P.A.T. Baltzer, M. Bernathova,
W. Bogner, S. Gruber, Z. Bago-Horvath, G. Karanikas, T.H. Helbich;
Vienna/AT (
[email protected])
Purpose: To determine whether correlations exist between imaging
biomarkers such as SUVmax with 18 FDG breast PET-CT or ADC with
diffusion-weighted imaging and choline (Cho) SNR with 1H-MRSI of primary
breast cancer (BC) lesions and IHC-derived receptor status.
Methods
and Materials: In this IRB-approved prospective study, 249 patients
with primary BC were included. Before surgery, all patients underwent 3 T MRI
including DWI with ADC measurements in all patients. Cho-SNR obtained by
3D-1H-MRSI was available in 62 cancers. 134 patients underwent 18 FDG
breast PET-CT and SUVmax of tumours was calculated. IHC was performed
on a surgical specimen. Appropriate statistical tests were used to test for
possible associations among ER, PR, HER2 and imaging biomarkers.
Results
A significant association was found between a triple negative status
and the SUVmax (p < 0.001) of breast cancer. ER-negative BC (mean
SUVmax 9.9) demonstrated a significantly higher SUVmax than did ER-
positive BC (median SUV, 5.1) (p= 0.02). A statistical significant difference was
found for SUVmax of PR-negative vs. PR-positive lesions with a mean
SUVmax of 7.7 and 4.9 (p=0.026), respectively. No such associations were
found for ADC and Cho measurements (P 0.556). HER2 receptor status did
not correlate with any imaging biomarker (P 0.252).
Conclusion
Receptor status of BC correlates with SUVmax. ER-negative BC
displays higher 18 FDG uptake than ER-positive BC. Triple-negative BC is
associated with increased 18 FDG-uptake commensurate with its aggressive
biology. No such associations were found for ADC and Cho measurements
(P0.556). HER2 receptor status did not correlate with any imaging biomarker
(P0.252).
14:00 - 15:30 Room G/H
Genitourinary
SS 1807
New frontiers in GU imaging
Moderators:
B. Brkljacic; Zagreb/HR
M. Notohamiprodjo; Munich/DE
B-1002 14:00
Added value of functional MRI with diffusion-weighted imaging (DWI) and
ADC map in characterisation of undetermined adrenal lesions:
comparison with chemical shift imaging
C.R.G.L. Talei Franzesi, D. Ippolito, P.A. Bonaffini, O. Minutolo, M. Colombo,
S. Sironi; Monza/IT (
[email protected])
Purpose: To assess the diagnostic performanc e of diffusion-weighted imaging
(DWI) with apparent diffusion coefficient (ADC) value, in the evaluation and
characterisation of indeterminate adrenal lesions.
Methods
and Materials: From October 2011 to may 2013, a total of 87
patients (36 women, 51 men; mean age 56 years; range 31-85 years) with
different benign and malignant adrenal lesions (adenomas, myelolipomas,
metastases and primitive carcinomas) were prospectively evaluated on a 1.5 T
MRI scan (Achieva, Philips), with a phased array multi-coil, using a
conventional study protocol that included also the acquisition of DWI
sequences with b-values of 0, 300, 500 and 1000 mm
2/sec. DWI were
compared with T1 FFE in- and out of phase. Mean ADC values of adrenal
lesions were calculated, manually drawing a region of interest (ROI) along the
contours of adrenal lesion on corresponding maps. Then, obtained data were
compared and correlated with chemical shift images and statistical analysis
was performed.
Results
The diagnosis of adrenal lesions was proved either by follow-up
examinations (stability or size increase over a period of time) or through
biopsy. All adrenal lesions showed restricti on of diffusion and motion of water
protons on DWI images. There was no significant difference in ADC values
calculated between adenomas (mean value: 1182 ±87.3 mm
2/sec),
myelolipomas (mean value:1245 ±180.6 mm2/sec) and primitive tumours (mean
value:1164±79.2 mm2/sec). The adrenal metastases (mean
value:910±87.5 mm2/sec) presented lower ADC value as compared to the
other adrenal lesions but not statistical ly significant difference were achieved
(p> 0.05).
Conclusion
The DWI and ADC map are not useful to differentiate between
benign and malignant adrenal lesions, but may be helpful in detection of small
adrenal lesions. The chemical shift imag ing technique remains the most useful
sequences for characterisation of indeterminate adrenal lesions.
B-1003 14:09
Elastosonography with transvaginal approach in assessing response to
MRgFUS treatment of uterine fibroids: preliminary experience
C. Marigliano, F. Ciolina, L. Molisso, G. Panzironi, A. Napoli, P. Ricci; Rome/IT
(
[email protected])
Purpose: To investigate the effects of Magnetic Resonance guided Focused
Ultrasound (MRgFUS) treatment on fibroids as found at multiparametric
ultrasound (US) and real-time elastography (RTE) with transvaginal (TV)
approach in symptomatic patients.
Methods
and Materials: Ten women (mean age 34) with 10 uterine fibroids
were treated with MRgFUS using ExAblate 2100 device (FDA treatment
guidelines). All patients performed TV-US before (time0) and after (time1)
MRgFUS within the same day. Follow-up TV-US was performed after 3 months
(time2). All patients performed CE-MRI following the same schedule. The
following features at time0, 1 and 2 were analysed: maximum diameter, color
doppler, elastosonography and strain ratio (SR) between fibroids and normal
myometrium.
Results
Four/10 patients had a good response (> 80%), 6/10 partial response
(< 50%) in terms of NPV (non-perfused volume) as assessed at post treatment
CE-MRI. Comparing US-parameters as assessed at time0 vs time1, and 2 we
found: decrease in color doppler signals in most of the patients (8/10); no
significant difference in maximum diameter comparing time0 to time1 and 2.
RTE TV-US showed a significant decrease in SR in 2/10 patients at time1
follow-up, while 3/10 had an increase in SR and in 5/10 there were no
difference. At time2 follow-up, as compared to time0, 8/10 patients had a
decrease of mean SR after treatment.
Conclusion
Elastosonography is a new diagnostic tool usefull for characterise
fibroids for MRgFUS and can be usefull to assess the efficiency of treatment.
Further data are needed to confirm our preliminary findings.
B-1004 14:18
Assessment of delayed renal allograft function by arterial spin-labelled
magnetic resonance imaging: comparison with kidney biopsy
K. Hueper, M. Gutberlet, F. Lehner, J.U. Becker, M.J. Peperhove,
A. Großhennig, F. Wacker, W. Gwinner, D. Hartung;
Hannover/DE (
[email protected])
Purpose: Delayed renal allograft function (DGF) is defined as failure of serum
creatinine to decrease or need for dialysis during the first week after
transplantation. DGF is associated with an increased risk of graft loss and
acute rejection. We investigate whether arterial spin labelling (ASL) allows
detection of DGF.
Methods
and Materials: Fourty patients were examined 4-10 days after
kidney transplantation using a 1.5-T magnet. Flow alternating inversion
recovery (FAIR) trueFISP ASL-sequences were acquired and parameter maps
of renal perfusion were calculated. DGF was diagnosed by a nephrologist.
Renal biopsy was available in 16/40 patients. Statistical analysis comprised
unpaired t-tests, ANOVA and correlation analysis. Perfusion values were
adjusted for recipient age, gender and the day of MRI.
Results
DGF was diagnosed in 19/40 patients, 42% of them had an acute
rejection at histology. Patients with DGF were significantly older, donor serum
creatinine was higher and cold ischaemi a time was longer. Renal perfusion in
DGF-patients was significantly reduced to 218 ±18 ml/(min*100 g) compared to
patients with normal initial graft function (324 ±18 ml/(min*100 g); p < 0.001). In
the subgroup of DGF-patients with acute rejection, renal perfusion was even
lower (180 ±24 ml/(min*100 g)) compared to the subgroup of DGF-patients
without rejection (p < 0.05) and to patients with normal graft function
(p < 0.001). Renal perfusion correlated with eGFR at the day of MRI and after
3-months (r=0.69 and r=0.55, respectively).
Conclusion
Non-invasive renal perfusion measurement by ASL allows
detection of DGF and renal perfusion signi ficantly correlates with allograft
function. Thus, ASL-MRI may improve diagnosis of patients early after kidney
transplantation.
S353
BA C D E F G
Monday
B-1005 14:27
Functional evaluation of the kidneys in renal artery stenosis using
diffusion tensor imaging
C. Gaudiano1, F. Busato1, B. Corcioni1, V. Clementi2, R. Golfieri1; 1Bologna/IT,
2Milan/IT (
[email protected])
Purpose: To evaluate the capability of the diffusion tensor imaging (DTI) to
detect parenchymal involvement in renal artery stenosis (RAS) by measuring
apparent diffusion coefficient (ADC) and fractional anisotropy (FA).
Methods
and Materials: Seventeen patients with RAS (10 men; mean age
52.3 years) and 15 patients (9 men; mean age 37.7 years) who did not have
kidney diseases, were studied with a 1.5 T MRI scanner. RAS was detected
using contrast-enhanced magnetic resonance angiography (CE-MRA). In all
cases, DTI sequence was added to the routine MRI protocol. Cortical and
medullary regions of interest (ROI) were placed to obtain the corresponding
ADC/FA values. Normal kidneys constituted the control group and kidneys with
haemodynamic RAS ( > 50%) constituted the study group. Student's t test was
used to compare the mean values of ADC and FA, for each ROI site, between
the two groups.
Results
Mean values of ADC and FA in the control group were:
2.53±0.16×10
3 mm2/s for cortical ADC, 2.21 ±0.18×103 mm2/s for medullary
ADC, 0.31 ±0.062 for cortical FA and 0.39 ±0.055 for medullary FA. There was
no significant difference between the two kidneys. By using CE-MRA,
haemodynamic RAS was detected in 14 patients, bilateral in 2: overall, 16
kidneys constituted the study group. The comparison between the two groups
showed that medullary ADC and FA in the study group were significantly lower
than in the control group ( P=0.034 and 0.022, respectively); there was no
significant difference for the other parameters.
Conclusion
The DTI could be a useful tool in evaluating renal alteration in
haemodynamic RAS.
Author Disclosures:
V. Clementi: Employee; General Electric Medical Systems.
B-1006 14:36
Mapping of T1 relaxation time for assessment of renal pathology
following ischaemia-induced acute kidney injury in mice
M.J. Peperhove, M. Gutberlet, D. Hartung, M. Meier, S. Rong, S. Tewes,
F. Wacker, F. Gueler, K. Hueper;
Hannover/DE (
[email protected])
Purpose: Acute kidney injury (AKI) leads to inflammation, tubular necrosis and
renal insufficiency. The purpose was to investigate whether T1-mapping allows
evaluation of renal pathology in a mouse model of ischaemia-induced AKI.
Methods
and Materials: AKI was induced in C57Bl/6-mice by transient
clamping of the right renal pedicle for 35 min (n=10, moderate AKI) or 45 min
(n=7, severe AKI). MRI was performed before surgery and at five time points
thereafter (d1-d28) using a 7-Tesla magnet. T1-maps were calculated from a
fat-saturated echoplanar inversion recovery sequence, and mean T1-values of
renal cortex, outer and inner medulla were determined. Kidney volume and the
degree of tubular injury at histology were assessed in all animals after the last
MRI. Statistical analysis comprised unpaired t-tests, ANOVA, correlation and
ROC-curve analysis.
Results
Following AKI, a significant T1-increase, indicating tissue oedema,
occurred in all anatomical layers at d7 with highest values in the outer medulla.
Compared to pre-surgery values, T1-values after severe AKI were significantly
higher (138 ±2%) than after moderate (121 ±3%, p=0.001), and T1-increase
persisted until d28 (123 ±4%, p < 0.05). Already at d7, T1-values in the outer
medulla negatively correlated with relative kidney volume and positively with
the degree of tubular injury four weeks after AKI (r=-0.93 and r=0.87,
respectively). ROC-curve analysis revealed that T1-increase > 1525 ms at d7
predicts significant tubular injury > 5% after four weeks with sensitivity and
specificity of 100% (AUC=1).
Conclusion
T1-mapping allows non-invasive detection of renal damage after
AKI in mice and predicts further outcome by assessment of tissue oedema and
structural abnormalities.
B-1007 14:45
3 T Diffusion tensor imaging (DTI) in the evaluation of periprostatic nerve
bundle before and after radiation therapy
C. Zini, V. Panebianco, F. Barchetti, D. Musio, V. Forte, C. Catalano; Rome/IT
(
[email protected])
Purpose: To assess the use of diffusion tensor imaging (DTI) at 3 T for
evaluating the periprostatic nerve bundle in terms of neuroanatomical
distribution, density and relationship with the capsule before and after radiation
therapy (RT).
Methods
and Materials: 63 patients with unresectable prostate cancer were
enrolled. All underwent a prostate Multiparametric-MRI examination at 3 T
magnet (Discovery M750, GE) equipped with an endorectal and a surface coil,
before and after 2 months of radiation treatment (35 cycles). Scan protocol
included: a morphological study obtain ed with TSE high-resolution T2-weighted
sequences on multiple plans, a dynamic study with contrast medium for lesion
localisation, a diffusion study (DWI) with different b values (500.1000,3000)
and DTI technique (fibre tracking) using a b value of 1000 with 16 directions.
Results
In all cases before RT it has been possible to display the periprostatic
nerve bundle in terms of anatomical di stribution, density and distance of the
nerve fibres from the capsule; after RT we observed a findings' superposition in
27 patients, partial fibres integrity in 31 patients (fibre loss ranging from 19% to
35%) and massive rarefaction in 5 patients (fibre loss ranging from 42% to
59%). These results compared with IIEF-5 test showed a statistically
significative correlation (p < 0.05).
Conclusion
DTI technique allows a complete visualisation of periprostatic
nerve bundle and plays an important role in evaluating damaged fibres in
patients who underwent RT.
B-1008 14:54
Diffusion tensor imaging of the kidney with optimisation of the b value:
the initial clinical experience
Q. Feng
1, Z. Ma1, J. Wu2; 1Tianjin/CN, 2Dalian/CN (
[email protected])
Purpose: To evaluate the fractional anisotropy (FA), apparent diffusion
coefficient (ADC), signal-to-noise ratio, contrast-to-noise ratio, ADC maps of
MR protocols with different b values and obtain the optimal b value of renal
diffusion tensor imaging (DTI) at 1.5 T.
Methods
and Materials: Twenty healthy volunteers with a mean age of 30 ±6
years were examined with a respiratory-triggered echo-planar DTI sequence of
the kidneys at 1.5 T (TR1400 ms; TE, 74-82 ms; 10 slices; slice thickness,
6 mm with no intersection gap; number of signals acquired, 4; diffusion
weightings b=0 and 200, 400, 600, 800, 1000 s/mm 2; 6 diffusion directions).
The regions of interests were placed in the cortex and medulla on the ADC
map using DTI task card software. The FA value, ADC value and signal
intensity were determined and SNR was calculated with the difference-image
method. Statistical analysis was performed using one-way ANOVA.
Results
The ADC values of renal parenchyma, cortex and medulla decreased
at higher b values, similar to the SNR of renal parenchyma, while the FA
values and CNR remained constant at different b values. The ADC values of
the cortex were significantly higher than those of the medulla, whereas the FA
values of the cortex were lower than those of the medulla. Image quality of the
ADC map decreased at higher b values, and b values (0 and 400, 600, 800
s/mm
2, respectively) can be applied to evaluate renal DTI.
Conclusion
Renal DTI (with a b value of 0, 600s /mm 2) was appropriate with
good cortex-medulla discrimination.
B-1009 15:03
Multiparametric MRI and state-of-the-art US techniques for the
characterisation of prostate cancer in the setting of MR-US fusion biopsy
T. Fischer, C. Stephan, T. Slowinski, A. Thomas, B. Hamm, T. Durmus;
Berlin/DE (
[email protected])
Purpose: To investigate whether multiparametric magnetic resonance imaging
(MRI) allows lesion localisation in prostate cancer in patients scheduled for
MR/US fusion biopsy and whether the findings correlate with state-of-the-art
ultrasound in terms of lesion characterisation and guidance of needle
placement.
Methods
and Materials: Fifty consecutive patients with elevated PSA levels
and a history of at least one negative TRUS-guided biopsy underwent
multiparametric 3 T MRI without an endorectal coil. MR Datasets (T2w, DWI)
were uploaded into a state-of-the-art ultrasound system (Aplio 500, Toshiba),
and images were fused in real-time mode during biopsy. Prostate lesions were
classified on the basis of MRI (T2w+DWI) and US (B-mode scan, power
Doppler, elastography/TDI, CEUS) using a 4-point semiquantitative analogue
scale (not suspicious, 0 - highly suspicious, 3). The maximum sum score was
15. Targeted biopsies were performed in the MR/US fusion mode followed by a
standard TRUS-guided biopsy.
Results
The detection rate was 40% in the fusion biopsy group versus 22% in
the standard TRUS group (p < 0.01). PSA levels were significantly higher in
patients with prostate cancer. The sum score was higher in the targeted biopsy
group with prostate cancer compared to those whose biopsy was negative
(11.6±2.7 versus 6.3 ±2.4; p < 0.05). The result correlates with the Gleason
score, which increased with the sum score.
Conclusion
Real-time MR/US image fusion may enhance cancer detection
rates of TRUS-guided biopsies and contributes to lesion characterisation by
state-of-the-art US techniques.
S354
BA C D E F G
Monday
B-1010 15:12
Quantitative Shear Wave ultrasound elastography and multi parametric
MR imaging performance for prostate cancer detection as a function of
size and Gleason score
J.-M. Correas, A. Khairoune, A.-M. Tissier, G. Khoury, O. Hélénon; Paris/FR
(
[email protected])
Purpose: To prospectively evaluate Shear Wave Elastography (SWE) and
multi-parametric MRI (mpMRI) diagnostic performance for prostate cancer
(PCa) detection and characterisation.
Methods
and Materials: 66 men underwent mpMRI (1.5 T, MR-Discovery,
GE, USA) and a transrectal SWE examination (AixPlorer, SuperSonic Imagine,
France).Two experienced radiologists independently analysed prostate sextant
stiffness and mpMRI. Biopsy core pathology (Gleason Score (GS) and PCa
size) of corresponding prostate sextants constituted the reference method. The
diagnostic performance (sensitivity (Se), spe cificity (Spe), positive predictive
value (PPV), negative predictive value (NPV)) at the sextant level was
calculated for SWE and mpMRI considering two PCa populations; PCa1:
size3 mm and GS 6; PCa2: size 9 mm and GS 7. For mpMRI, two scenari
were considered; for mpMRI1 the test was considered positive in the sextant if
at least one of T2, Diffusion, and DCE imaging was positive. For mpMRI2, at
least two sequences of the three were positive.
Results
A total of 748 sextants was analysed. 99 PCa foci were detected in
32 patients for PCa1 patient population, while for PCa2 36 foci were detected
in 16 patients. The different imaging technique performance are summarised
below (cutoff value of 35 kPa for SWE): PCa1: Se Spe PPV NPV, mpMRI1
44% 89% 50% 91%, mpMRI2 37% 93% 45% 91%, SWE 87% 86% 50% 98%,
PCa2: mpMRI1 72% 87% 33% 98%, mpMRI2 58% 91% 26% 98%, SWE 86%
98% 18% 99%.
Conclusion
mpMRI exhibited good performance for larger and aggressive
PCa while SWE provided good diagnostic performance for all PCas.
Author Disclosures:
J.-M. Correas: Speaker; Philips Healthcare, Toshiba Medical System,
SuperSonic Imagine, Bracco.
14:00 - 15:30 Room I/K
Neuro
SS 1811b
Neuroinflammation and infectious
diseases
Moderators:
E.L. Gasparetto; Rio de Janeiro/BR
K.-O. Løvblad; Geneva/CH
B-1012 14:00
Improved differentiation between MS and vascular brain lesions using
FLAIR* at 7 Tesla
I.D. Kilsdonk
1, M.P. Wattjes1, J.P.A. Kuijer1, M.C. de Jong1, M.M.A. Conijn1,
P.R. Luijten2, J.J.G. Geurts1, M.I. Geerlings2, F. Barkhof1; 1Amsterdam/NL,
2Utrecht/NL (
[email protected])
Purpose: Common question in daily radiology practice is the challenging
differentiation between multiple sclerosis (MS) lesions and white matter (WM)
lesions of vascular origin. We aimed to investigate the performance of a new
magnetic resonance (MR) image contrast called FLAIR*, at differentiating
between MS and vascular brain lesions, at 7 Tesla (T).
Methods
and Materials: We examined 16 MS patients (10 female, mean age
50.4 years) and 16 age-matched patients with (risk factors for) vascular
disease (6 female, mean age 50.9 years). 3D-FLAIR and 3D T2*-weighted
images were combined to generate FLAIR* images. Lesiontype and intensity,
perivascular orientation and presence of a hypointense rim were analysed.
Differences between patientgroups regarding lesion distribution and
perivascular orientation were tested with Fisher's exact test. In addition,
sensitivity and specificity of 7T FLAIR* were calculated.
Results
In total, 433 lesions were detected in MS patients versus 86 lesions
in vascular patients. Lesions in MS patients were significantly more often
oriented in a perivascular manner: 74% vs. 47% (P < 0.001). 8 MS lesions
(2.3%) were encircled by a hypointense rim, and 28 MS lesions (5.5%) were
hypointense on T2*. No vascular lesions showed any rim or hypointensity.
Specificity of differentiating MS from vascular lesions on 7T FLAIR* increased
when presence of a central vessel is taken into account (from 63% to 81%),
most obviously for deep white matter lesions (from 69% to 94%).
Conclusion
7T FLAIR* improves differentiation between MS lesions and
vascular brain lesions based on lesion type, perivascular orientation and
distinct morphological characteristics.
Author Disclosures:
I.D. Kilsdonk: Grant Recipient; Dutch MS Research Foundation (grant. no 11-
769), Noaber Foundation. M.P. Wattjes: Consultant; Biogen Idec. Speaker;
Biogen Idec, Bayer Healthcare, Roche, Janssen Cilag. J.J.G. Geurts:
Advisory Board; Dutch MS Research Foundation, MS Academics,
MerckSerono. Board Member; MS International, BMC Neurology. Consultant;
MerckSerono, Biogen Idec, TEVA. F. Barkhof: Board Member; Brain,
European Radiology, Radiology, Multiple Sclerosis, Neuroradiology.
Consultant; Bayer-Schering Pharma, Sanofi-Aventis, Biogen-Idec, TEVA,
MerckSerono, Novartis, Roche, Synthon BV, Janssen Research. Grant
Recipient; Dutch MS Society (EU-FP7). Speaker; Serono Symposia
Foundation.
B-1013 14:09
The clinical subtype of multiple sclerosis determines the timeline of
temporal lobe atrophy - a voxel based morphometry study
L.R. Kozák, A. Iljicsov, M. Simó, B. Dániel, G. Rudas, P. Barsi; Budapest/HU
(
[email protected])
Purpose: Temporal lobe atrophy is associated with the development of
disability and cognitive decline in multiple sclerosis (MS). We investigated
whether and how temporal gray matter (GM) volume loss depends on the
clinical course of MS.
Methods
and Materials: We retrospectively analysed 3 T-acquired contrast-
enhanced T1-weighted images of 46 patients (32 females, mean age:
36.2±8.7 yrs, mean disease duration: 57.6 ±50.3 months, mean expanded
disability status scale (EDSS): 1.5± 1.8); 7 patients had clinically isolated
syndrome (CIS), 19 relapsing-remitting (RR), 9 clinically benign RR (RR-B), 7
primary progressive (PP), and 5 secondary progressive (SP) disease course.
Voxel based morphometry was performed using the VBM8 toolbox of SPM8
package. Between-group differences were assessed using one-way ANOVAs
modeling interactions with EDSS and disease duration, respectively. Age and
gender served as nuisance variables in all models. Statistical parametric maps
were thresholded at p < 0.001 uncorrected, with a cluster-size threshold of 72
voxels.
Results
EDSS-score and disease duration had very similar strong and
significant positive correl ation across groups (r=0.52, p < 0.0001), thus for
brevity we only report the latter, below. The GM volume and disease duration
relationship was significantly different in the temporal lobes, insular cortices,
and superior temporal gyri bilaterally, and in the left temporal pole and right
anterior cingulate cortex. The middle temporal and insular cortices of the PP
and the superior temporal gyri of the RR, RR-B and SP groups showed the
most prominent deterioration.
Conclusion
There is differential involvement of the temporal lobes, insulae
and other areas depending on the clinical course of MS.
B-1014 14:18
Association of MR findings and serum bilirubin and uric acid levels
changes during neuroinflammation in patients with initial and relapsed
demyelisation attacks
D. Stojanov, S. Ljubisavljevi, S. Vojinovi, I. Stojanovi; Nis/RS
(
[email protected])
Purpose: To examine the endogenous antioxidants values in the earliest
phase of demyelisation, we have determined bilirubin and uric acid (UA) serum
values in the patients with clinically isolated syndrome (CIS) and relapsing
remitting multiple sclerosis (RRMS), regarding their clinical disability, measured
by Extended Disability Status Scale (EDSS) and magnetic resonance imaging
(MRI) disease activity.
Methods
and Materials: The cross-sectional study included 50 CIS patients,
aged 17-57 years, 57 RRMS patients, aged 23-58 years, and 20 control
patients, aged 23-45 years with non-specific neurological symptoms. All CIS
and RRMS patient's clinical presentations were assessed using EDSS. The
number of T2W hyperintense lesions and the lesion load of Gd-enhancing
lesions on T1W images were calculated. The lesion loads were calculated to
volumes. Serum total bilirubin, direct bilirubin and indirect bilirubin
concentration as well as UA serum values were measured.
Results
Obtained values of bilirubin and UA were higher in patients with lower
MRI lesion number, lower EDSS, and shorter disease duration (p < 0.05). The
Results
suggest negative linear correlation between bilirubin and UA levels and
MRI findings, disease duration, and EDSS in CIS (p < 0.01), with the same
correlation between bilirubin and UA levels and disease duration in RRMS
patients (p < 0.01). There was also significant correlation between bilirubin
level and MRI findings and UA levels and EDSS in RRMS patients (p < 0.01).
Conclusion
There is a negative linear correlation between bilirubin and UA
levels and MRI findings in CIS as well as significant correlation between
bilirubin level and MRI findings in RRMS patients.
S355
BA C D E F G
Monday
B-1015 14:27
Longitudinal DTI changes in multiple sclerosis patients with different
cortical reorganisation patterns
S. Kulikova, A. Peresedova, V. Bryukhov, O. Trifonova, M. Krotenkova,
I. Zavalishin; Moscow/RU (
[email protected])
Purpose: To investigate longitudinal changes of diffusion-tensor imaging (DTI)
data in relapsing-remitting multiple sclerosis (RRMS) patients with different
cortical reorganisation patterns.
Methods
and Materials: 25 patients with RRMS (7 men), all right-handed,
aged 19-50, underwent MRI (Avanto1.5 T, Siemens) during relapse with
unilateral light hand palsy, in three and twelve (20 of 25 patients) months after
it. Scanning protocol included functional MRI (fMRI) and DTI sequences. FMRI
was performed using simple movement paradigm for both hands. DTI data
were assessed in regions of interest:corticospinal tract (CST) - pons,
peduncles and internal capsules (IC) level; splenium (SCC) and motor area of
corpus callosum (MACC).
Results
Differently directed changes of primary sensorimotor cortex (SMC)
functional activity during relapse allowed us to divide all patients into two
groups: the first one with decrease of SMC activation on palsy-corresponding
side in comparison with opposite one (volume ratio (VR) range 0.22-0.79) and
the second one with the increase (VR range 1.17-6.19). During relapse these
groups differed by DTI indices in CST on the pons level, the first one also had
asymmetrical decrease of deep sensitivity on palsy hand (Mann-Whitney U
test, p < 0.05). In the follow-up, the first group was characterised by DTI
changes in palsy-corresponding medial lemniscus, CST on IC level and SCC,
the second group - in palsy-corresponding CST on pons and peduncles level
and in MACC (repeated measures ANOVA; Newman-Keuls post-hoc test,
p < 0.05).
Conclusion
RRMS relapse with similar palsy but different sensitivity
impairment is characterised by contrary cortical reorganisation patterns, which
are associated with different specific longitudinal structural changes, probably
due to initially different pathologic mechanisms.
B-1016 14:36
Update on CNS complications after allogeneic bone marrow transplant
M. Díez Blanco, E. López Uzquiza, M. Drake Pérez, J. Navasa Melado,
E. Marco de Lucas; Santander/ES (
[email protected])
Purpose: 1. To stand out the importance to know the different states of
immunosuppresion after a bone marrow transplant (BMT), in order to establish
a proper clinical-radiological correlation. 2. To review the main neuroimaging
findings of CNS complications observed after BMT.
Methods
and Materials: We review the neurological complications in 935
patients who had received an allogeneic bone marrow transplantion at our
hospital in the past 12 years. We analysed the neuroimaging findings (CT and
MRI) of forty-three patients with neurologic complications and their clinical and
autopsy correlation.
Results
The main neurologic CNS complications observed were: a) infections:
including viral (12 patients: EBV, CMV, HHV6), bacterial caused by
Pneumococcus in 3 cases, Toxoplasmosis in 2 cases, fungal (2 patients with
Aspergillus, Scedosporium); b) neoplasm recurrence (9 patients); c) toxic (3
patients); d) vascular complications in 6 patients including subarachnoid
haemorrhage, ischaemic strokes and TTP.
Conclusion
Over the last few years, there has been a significant decrease in
mortality and complications of BMT. It is essential to carry out a successful
clinical-radiological correlation to make a proper diagnostic orientation. Viral
infections are one of the biggest diagnostic challenges because MRI findings
are often subtle alterations and quite different from the usual lesions described
in immunocompentent patients.
B-1017 14:45
Evaluation of brain vascularity and perfusion in TB meningitis using
MRA/MR perfusion imaging
K. Rahmat, F. Abu-Bakar, N. Ramli, S. Tai, C. Tan; Kuala Lumpur/MY
(
[email protected])
Purpose: Cerebral vasculitis is one of the complications of tuberculous
meningitis (TBM). Cerebral infarctions in TBM commonly affect the basal
ganglia, thalamus and the internal capsule.The aim of this study is to evaluate
the imaging features, vasculitic changes and perfusion of the infarcted brain
regions in TBM comparing with the contralateral normal region/healthy
subjects.
Methods
and Materials: A prospective study of newly diagnosed TBM
patients was undertaken between March 2012-September 2013. Standard 3 T
brain MRI sequences (T1W, T2W, Flair, DWI, GRE), TOF MRA) and MR
Perfusion (Dynamic susceptibility contrast enhanced MR perfusion) were
performed at the time of diagnosis.
Results
A total of 8 patients were enrolled. Leptomeningeal and basal
cisterns enhancement and tuberculomas were demonstrated in all patients.
cerebral infarctions were demonstrated in 6 patients, with similar occurrence of
infarction in what has been described as 'TB zone', referring to the heads of the
caudate nuclei, anteromedial thalami and internal capsules.All patients
demonstrated vasculitis in the anterior or posterior circulations.All patients
demonstrated vasculitis in the anterior circulations mainly involving the M1, M2
and A1 segments. Vasculitis in the anterior and posterior circulations was
observed in 3 patients. Acute obstructive hydrocephalus was present in 6
patients. MR perfusion study in 4 patients with acute infarctions showed
significantly low rCBV and rCBF and increased MTT.
Conclusion
Vascular abnormality mainly affected the middle cerebral,
anterior cerebral and supraclinoid internal carotid arteries. Area of acute
infarctions shows significant reduction in rCBV and rCBF with prolonged MTT
compared to the contralateral normal regions.
Author Disclosures:
K. Rahmat: Grant Recipient; RG390/09H
TM. F. Abu-Bakar: Grant Recipient;
RG390/09HTM. N. Ramli: Grant Recipient; RG390/09HTM.
B-1018 14:54
Diffusion-weighted tractography to reconstruct the optic radiation in
support of temporal lobe epilepsy surgery
S.P.L. Meesters1, P.P.W. Ossenblok2, B.M. ter Haar Romeny1, O. Schijns3,
L. Wagner2, P. Hofman2, A. Vilanova1; 1Eindhoven/NL, 2Heeze/NL,
3Maastricht/NL
Purpose: Surgical resection of drug-resistant temporal lobe epilepsy (TLE)
leads most pf the candidates to seizure relief. However, disruption of the optic
radiation (OR) leads to a visual field deficit (VFD). Diffusion-weighted
tractography was applied to reconstruct the OR and pre-operatively predict the
VFD. Methodological improvements were made to provide the most reliable
reconstruction and its plausibility was evaluated.
Methods
and Materials: Diffusion tensor imaging (DTI) is of limited use due to
its inability to resolve crossing fibers. Constrained spherical deconvolution
(CSD) can describe multiple orientations from the fiber orientation density
function. To correct for echo-planar imaging (EPI) distortions, an unwarping
Method
using two-phase encoding directions was evaluated against the
fieldmap method for healthy volunteers (n =4). The post-operative damage to
the OR in relation to the resection area was compared to pre-operative
reconstructions for TLE surgery candidates ( n=3).
Results
Reconstructions of the OR with CSD were better described by the
underlying diffusion data. The estimat ed EPI distortions using the two-phase
encoding direction method showed a shift of distance of the temporal pole to
the anterior extent of the OR in the order of 1 cm. Pre- to post-operative
comparisons indicated a good correlation between expected and observed
damage to fibers. The presented results are visualised using a 3D smart
image.
Conclusion
Significant shifts due to distortions were observed, demonstrating
the importance of correction. In the absence of a ground truth, pre- to post-
operative comparison allows validation of the reconstruction of the OR, useful
for preoperative prediction of VFD.
B-1019 15:03
Comparative evaluation of fungal and pyogenic brain abscesses with
susceptibility-weighted imaging
R. Antulov
1, K. Dolic2, J. Fruehwald-Pallamar3, D. Miletic1, M.M. Thurnher3;
1Rijeka/HR, 2Split/HR, 3Vienna/AT (
[email protected])
Purpose: Conventional MRI techniques are inadequate to determine the
causative agent of brain abscesses. We investigated the value of susceptibility-
weighted imaging (SWI) in the differentiation of fungal and pyogenic brain
abscesses and the effect of field strength (1.5 T versus 3 T) in SWI for the
detection of specific imaging characteristics of brain abscesses.
Methods
and Materials: MRI studies of 10 patients with pyogenic and 6
patients with fungal brain abscesses were reviewed. Ten patients underwent
examinations on a 3 T scanner and six patients on a 1.5 T scanner. Imaging
characteristics on conventional MRI, diffusion-weighted imaging (DWI) and
SWI were recorded in all abscesses. All lesions were assessed for the
presence of a "dual-rim sign" on SWI.
Results
Homogeneous hyperintensity on DWI was present in 88% of
pyogenic abscesses, but in only 7.1% of fungal abscesses. On SWI, 94% of
pyogenic abscesses had a complete low signal intensity rim, while 17.9%
fungal abscesses showed a complete low signal rim. On a 3 T scanner, the
"dual-rim sign" was apparent in all pyogenic abscesses. None of the pyogenic
abscesses or any of the fungal abscesses were positive for a "dual-rim sign" on
a 1.5 T scanner.
Conclusion
In fungal abscesses, the "dual-rim sign" is not present, but rather,
a prominent peripheral rim or marked central susceptibility effects will be seen.
The appearance of pyogenic abscesses on SWI depends on the field strength,
with the "dual-rim sign" a specific feature of pyogenic brain abscesses on a 3 T
scanner.
S356
BA C D E F G
Monday
B-1020 15:12
Brain involvement in patients with inflammatory bowel disease: a voxel-
based morphometry and diffusion tensor imaging study
A. Zikou, M. Kosmidou, L. Astrakas, L. Tzarouchi, E. Tsianos,
M.I. Argyropoulou; Ioannina/GR (
[email protected])
Purpose: Investigation of structural brain changes associated with
inflammatory bowel disease (IBD) by assessing the presence of white-matter
hyperintensities (WMHIs) and applying voxel-based morphometry (VBM) and
tract-based spatial statistics (TBSS) methods.
Methods
and Materials: Brain magnetic resonance imaging (MRI) was
performed on 18 patients with IBD aged 45.16 ± 14.71 years and 20 aged-
matched control subjects. The imaging protocol consisted of a sagittal fluid-
attenuation-inversion-recovery (FLAIR), a T1-weighted high-resolution 3-
dimensional spoiled gradient-echo sequence, and a multisection spin-echo
planar diffusion-weighted sequence. Differences between patients and control
subjects in brain volume and diffusion indices were evaluated using the VBM
and TBSS methods, respectively. The presence of WMHIs was evaluated on a
sagittal FLAIR sequence.
Results
VBM revealed decreased grey matter (GM) volume in patients with
IBD in the fusiform and the inferior temporal gyrus bilaterally, the right
precentral gyrus, the right supplementary motor area, the right middle frontal
gyrus and the left superior parietal gyrus (p < 0.05), but no significant
difference was observed in white matter (WM) volume. TBSS showed
decreased axial diffusivity (AD) in the right corticospinal tract and the right
superior longitudinal fasciculus in the patients with IBD compared to the control
subjects, and a larger number of WMHIs was observed in the patients
(p < 0.05).
Conclusion
Patients with IBD show an increase in WMHIs and GM atrophy,
probably related to cerebral vasculitis and ischemia. Decreased AD in their
major WM tracts could be a secondary phenomenon, representing Wallerian
degeneration.
B-1021 15:21
Preserved white matter integrity is a marker of familial longevity
I. Altmann-Schneider, A. de Craen, I. Veer, A. van den Berg-Huysmans,
P. Slagboom, R. Westendorp, M. van Buchem, J. van der Grond; Leiden/NL
(
[email protected])
Purpose: Brain tissue integrity is highly heritable. Its decline is a common
ageing phenomenon. This study aimed to determine whether the phenotype of
familial longevity is marked by a relative preservation of brain tissue
microstructure.
Methods
and Materials: Participants came from the Leiden Longevity Study.
In total, 185 elderly offspring of nonagenarian siblings, who are enriched for
familial factors of longevity, were contrasted with 171 environmentally and age-
matched controls. All subjects underwent 3 T whole brain MR diffusion tensor
imaging.
Results
Voxel-wise analysis revealed widespread age-related decrease of
white matter fractional anisotropy and increase of axial, radial and mean
diffusivity (all p < 0.003). Offspring showed higher mean white matter fractional
anisotropy (Mean (SE): offspring: 0.3232 (0.0009); controls: 0.3212 (0.0009), p
= 0.04) compared to control subjects independent of cardiovascular risk
factors. When differences in white matter diffusion parameters between
offspring and control subjects were assessed voxel-wise, offspring showed
higher white matter fractional anisotropy and lower white matter radial
diffusivity predominantly in the callosal genu and body (both p < 0.003). Taking
the effect of chronological age on white matter microstructure into account,
offspring can be considered 4.5 years "biologically younger" compared to
control subjects concerning white matter integrity.
Conclusion
Both elderly offspring of nonagenarian siblings and control
subjects show common age-related decline of white matter integrity, which is
less marked in the callosal genu and body among the offspring, corresponding
to a biological age benefit of 4.5 years.
Author Disclosures:
A. de Craen: Grant Recipient; Grant. P. Slagboom: Grant Recipient; Grant.
14:00 - 15:30 Room L/M
Physics in Radiology
SS 1813
Advances in digital x-ray imaging
Moderators:
H. Bosmans; Leuven/BE
S.J. Foley; Dublin/IE
B-1022 14:00
Digital subtraction angiography: can we reduce the dose maintaining
enough image quality?
H. de las Heras
1, J. Fernández Soto1, R. Torres2, I. Hernando2,
E. Vañó Carruana1; 1Madrid/ES, 2Valladolid/ES (
[email protected])
Purpose: Suggest a practical method for dose optimisation in digital
subtraction angiography using three different kinds of phantoms.
Methods
and Materials: Series of images using digital subtraction
angiography were obtained in two different angiography systems for two
different patient thicknesses simulated by PMMA plates. Three commercially
available phantoms (following IEC/German, British and NEMA standards) were
used to assess the features of digital subtraction: mask creation and
logarithmic subtraction, dynamic range and contrast sensitivity. In addition,
image quality was quantified using measur ements of signal-difference-to-noise
ratio (SDNR). Phantom entrance dose was measured with both an ionisation
chamber and a solid-state detector.
Results
Available phantoms can be used for quality control of the digital
subtraction and simultaneously for the quantification of image quality and
consequent dose optimisation. For the IEC-DIN phantom, visibility of 5 mg
Iodine per ml of contrast at a vascular diameter of 1 mm within homogeneous
Background
was identified with SDNR > 0.20 for a phantom entrance air kerma
of 0.43 mGy/image. Equivalent thresholds were found for the British standard
phantom and for the NEMA phantom. Similar thresholds for other contrast
concentrations can be used to pre-define exposure modes, which may be
chosen by the radiologist during the procedure depending on the imaging task.
Conclusion
Dose optimisation of devices featuring digital subtraction can be
carried out with a single dedicated phantom. The exposure modes can be
adjusted to tasks of different complexity by simultaneous measurement of dose
and quantification of image quality.
Author Disclosures:
H. de las Heras: Consultant; QUART GmbH.
B-1023 14:09
Comparison of image quality and radiation dose measurements between
an image-intensifier system and a solid-state detector system
M. Weidner, C. Hagelstein, T. Diehm, S.O. Schönberg, K.W. Neff;
Mannheim/DE (
[email protected])
Purpose: To compare image contrast, image resolution and radiation dose
between an image-intensifier based system and a solid-state detector based
system both used in a paediatric radiology unit.
Methods
and Materials: Using a technical phantom (Primus DL, IBA,
Germany) two imaging systems---a conventional image-intensifier system
(Philips Easy Diagnost, Philips Healthcare, The Netherlands) and a new solid-
state detector system (Luminos Agile, Siemens Healthcare Sector, Germany)--
-were compared. Dosimetry was performed by an ion chamber and by the
dose area product. Image contrast and image resolution were evaluated
visually by comparing the number of detectable contrast objects and the
number of line pairs per millimetre (lp/mm), respectively. Two different modes--
-a fluoroscopic (20 sec exposure time, 3 pulses per sec, 5 measurements) and
a radiographic mode---were compared in all possible magnifying steps.
Results
Image contrast was equal in both systems. Image resolution was
increased by the solid-state detector system in comparison to the image-
intensifier system both in the fluoroscopic mode (1.5 lp/mm vs. 1.3 lp/mm) and
the radiographic mode (1.9 lp/mm vs. 1.3 lp/mm). Radiation dose was reduced
by the solid-state detector system in fluoroscopic mode (0.9 vs. 2.7 mGy,
p < 0.0001) and in radiographic mode (0.4 vs. 2.2 mGy). Radiation dose
reduction measured by the radiation dose area product was equivalent.
Conclusion
With the new solid-state detector system an equal image
contrast, higher image resolution and a lower radiation dose can be achieved
in comparison to the conventional image-intensifier system. The solid-state
detector system is therefore preferred for use in paediatric radiology.
Author Disclosures:
M. Weidner: Equipment Support Recipient; Cooperation with Siemens
Healthcare Sector. T. Diehm: Equipment Support Recipient; Cooperation with
Siemens Healthcare Sector. S.O. Schönberg: Equipment Support Recipient;
Cooperation with Siemens Healthcare Sector. K.W. Neff: Equipment Support
Recipient; Cooperation with Siemens Healthcare Sector.
S357
BA C D E F G
Monday
B-1024 14:18
Comparative study of the corrosion behaviour of peripheral stents in a
accelerated corrosion model: experimental in vitro study of 28 metallic
vascular endoprostheses
K.J. Kutter, P.M. Paprottka, M.F. Reiser, T. Waggershauser;
Munich/DE (
[email protected])
Purpose: Clinical cases of stent-fractures caused by corrosion show that the
selection of stents due to their corrosion behaviour might play a role. Implanted
in vivo, especially in combination with other implanted foreign-materials, stents
are exposed to special conditions, which can cause a process of corrosion.
Methods
and Materials: 28 peripheral stents of different materials (nitinol,
cobalt-chromium-nickel, tantalum, V4 A) and surface treatments (electro-
polishing, mechanical-polishing, without polish) were tested in vitro. Corrosion
was accelerated by applying a constant voltage of 3.5 volts and amperage of
1.16 mA in 0.9% NaCl. At defined points-of-time, the stents were investigated
for macroscopic and microscopic damage.
Results
Nitinol stents showed the lowest susceptibility to corrosion and the
longest period without damage. The Memotherm II was the only stent that
showed neither macroscopic nor microscopic damages. The worst material
was cobalt-chromium-nickel. Here corrosion damages already occurred about
1/10 earlier compared to nitinol. Considering the reasons for determination of
the test nitinol stents primarily showed length deficits, V4 A and tantalum stents
mainly fractures. Cobalt-chromium-nickel stents had half a fraction in multiple
parts or a complete lysis. Placed in direct contact nitinol stents came out on
top, regardless of what material they were combined with. Testing the influence
of polishing treatments, electro-polished stents performed best, mechanical-
polished and stents without polishing treatment followed.
Conclusion
All available stents are actual a compromise on advantages and
disadvantages. The analysis of the corrosion behaviour is thus a necessary
basis to provide a large number of different stents to fulfill the individual needs
of patients.
B-1025 14:27
Radiation doses to patients in interventional cardiology procedures
L. Sukupova; Prague/CZ (
[email protected])
Purpose: A number of procedures in cardiology are performed under
fluoroscopy control with cine series, e.g. coronary angiography (CA),
percutaneous transluminal coronary angioplasty (PTCA), closure of patent
foramen ovale (PFO), implantation of pacemakers (PM) and implantable
cardioverter-defibrillators (ICD), but also electrophysiological procedures
(RFA). It is not long ago when transcatheter implantations of aortic valve
(TAVI) began. This study provides information about radiation burden of
patients undergoing mini-invasive cardiological procedures.
Methods
and Materials: All procedures except implantation of PM and ICD
were performed on angiography x-ray systems (2005-2012) which provides the
radiation dose structured report useful for assessment of patient doses.
Implantations of PM and ICD are performed on a different x-ray system,
providing only total PKA and fluoroscopy time. For patient's dose assessment,
only PKA values were used. In this study, a following number of patients were
included: CA-517, CA+PTCA-157, PFO-13, PM-94, ICD-94, RFA-250, TAVI-
22. The CA group includes not only patients with coronary angiography, but
sometimes left ventriculography was a part of exam. The RFA group includes
patients treated for atrial fibrillation, atrial flutter, and other.
Results
Average values of PKA (Gy.cm2) are as follows: CA-39 Gy.cm2,
CA+PTCA-94 Gy.cm2, PFO-21 Gy.cm2, ICD-26 Gy.cm2, PM-17 Gy.cm2,
RFA-10 Gy.cm2, TAVI-249 Gy.cm2.
Conclusion
Highest doses are associated with TAVI and lowest with RFA.
According to the number of procedures performed annually, doses from
CA+PTCA most significantly contribute to the collective effective dose.
B-1026 14:36
European skin-dose trigger levels for interventional radiology and
cardiology procedures
A. Trianni
1, J. Farah2, E. Carinou3, J. Dabin4, J. Domienik5, H. Järvinen6,
A. Negri7, L. Novak8, Z. Knezevic9; 1Udine/IT, 2Fontenay-aux-Roses/FR,
3Athens/GR, 4Mol/BE, 5Lodz/PL, 6Helsinki/FI, 7Padova/IT, 8Prague/CZ,
9Zagreb/HR (
[email protected])
Purpose: The large use of fluoroscopy in interventional radiology procedures
may induce unintended patient skin injuries. To help physicians and staff
recognise and avoid situations at risk, trigg er levels based on online dosimetric
indicators, available on most of the new angiography equipment, have been
introduced. However, such trigger levels are usually centre and procedure
dependant. This work aims to evaluate the feasibility of establishing a
European set of trigger levels for high-risk interventional procedures.
Methods
and Materials: Within EURADOS WG12 9, European countries
performed measurements in clinical settings to evaluate the correlation
between maximum skin dose (MSD) and cumulative air kerma (CK) at the
Reference
interventional point. This easy-to-use method provides the staff with
real-time MSD estimates. The study focused on the PTCA (coronary
angioplasty), NE (neuroembolisations) and CE (chemoembolisations)
procedures which extensively use x-rays.
Results
The MSD showed good correlation with CK for the evaluated
procedures despite the multiple factors affecting MSD including skin dosimetry
uncertainties, operator's experience and methodology. Two provisional
European trigger levels have been established: 5.5 Gy for CE and 2.5 Gy for
NE which indicate a 3 Gy skin dose. Trigger level for PTCA is still under
evaluation.
Conclusion
Trigger levels are still a necessary tool, until real-time dose
mapping systems become available on angiographic equipment to identify
situations associated with high probability of exceeding the dose threshold for
deterministic effects. Future steps will include extending the work to other
radiology procedures pooled depending on their tube projections, field of view
and equipment protocols.
B-1027 14:45
Monte Carlo reference data sets for imaging research: results of the
American Association of Physicists in Medicine (AAPM) task group no.
195
I. Sechopoulos
1, E. Ali2, A. Badal3, A. Badano3, J. Boone4, E. Mainegra-Hing2,
K.L. McMillan5, D.W.O. Rogers2, A. Turner5; 1Atlanta, GA/US, 2Ottawa, ON/CA,
3Silver Spring, MD/US, 4Sacramento, CA/US, 5Los Angeles, CA/US
(
[email protected])
Purpose: To develop a set of reference Monte Carlo simulations relevant to
diagnostic imaging research for use by researchers needing to validate their
own simulations.
Methods
and Materials: Complete details of six different Monte Carlo
simulations relevant to x-ray diagnostic imaging have been developed and
implemented using four well-established software packages (EGSnrc, Geant4,
Penelope and MCNP). The simulations implemented are: x-ray half value layer
characterisation; dosimetry and x-ray scatter in radiography, mammography,
body and breast tomosynthesis; dosimetry in body CT; and x-ray production.
Results
obtained with the four software packages were compared. The Task
Group report includes complete details of the simulation conditions and all
results.
Results
Excellent agreement was found among the four implementations of
all six simulation conditions. The simulation of x-ray production showed the
largest differences among the different codes due to the complexity of the
physics involved and the many physics parameter options available in each
code. During implementation of the simulations, many lessons were learned on
differences in interpretation of simulation conditions and behaviour of the
software packages. These are included in the Task Group report. The relative
efficiency of the codes varied considerably.
Conclusion
When simulation conditions were equivalent, results obtained
with the four Monte Carlo packages tested were consistent. However, ensuring
that all simulation conditions match is not straightforward. The publication of
the details of all simulation conditions and results will be useful to other
researchers who need to validate their own Monte Carlo simulation software.
B-1028 14:54
Quantitative assessment of the spatial dependence of non-stationary
high-contrast spatial resolution, low-contrast detectability, and noise
behaviour in 3D imaging of the breast
C. Steiding, D. Kolditz, A.-C. Roessler, W.A. Kalender;
Erlangen/DE (
[email protected])
Purpose: To investigate the dependence of objective image quality (IQ)
metrics on direction and position in th e 3D volume for breast tomosynthesis
(BT) and breast computed tomography (bCT).
Methods
and Materials: In addition to standard IQ procedures, we focused on
assessing physical imaging performance in the central and the peripheral field
of measurement (FOM) in radial, azimuthal, and axial direction. Two
homogeneous tissue-equivalent phantoms mimicking compressed and
pendant female breasts were designed and equipped with identical test inserts.
For the evaluation of in-plane and axial resolution, 3D low-contrast
detectability, and spatially-dependent noise behaviour, the modulation transfer
function's 10% value (MTF10%), slice sensitivity profile's full width at tenth
maximum, object size-dependent contrast-to-noise ratio (CNReff), and local
noise power spectra (NPS) were determined. Measurements were carried out
on a clinical BT and a prototype high-resolution bCT system at comparable
dose levels.
Results
Both modalities showed MTF10% > 5 lp/mm in the center and
spatially asymmetric noise behaviour of local volumes through 3D NPS
estimation. Massive discrepancies between in-plane and axial system
response was determined in BT, while bCT featured isotropic resolution. In BT,
the smallest low-contrast insert (2 mm) was not revealed in the center, as
indicated by CNReff < 5. For bCT, CNReff was significantly higher and all low-
contrast structures were visible regardless of their position.
S358
BA C D E F G
Monday
Conclusion
Assessing only transverse system response in the central FOM
appears to be insufficient since resolution, image contrast, and noise depend
critically on direction and position.
Author Disclosures:
C. Steiding: Employee; CT Imaging GmbH. D. Kolditz: Employee; CT
Imaging GmbH. W.A. Kalender: CEO; CT Imaging GmbH. Founder; CT
Imaging GmbH.
B-1029 15:03
Evaluation of DNA damage induced by total body CT scans
N. Della Vecchia, F. Giurazza, R. Del Vescovo, B.B. Zobel; Rome/IT
(
[email protected])
Purpose: The cellular damage induced by ionizing radiation has been
previously quantified analyzing the DNA double strand breaks (DSBs) in
lymphocytes through the rate of 3-H2 AX phosphorylated histone protein. We
aimed to demonstrate and quantify molecular damage induced from ionizing
radiation by evaluating t he expression of histon 3-H2 AX in lymphocites of
patients who underwent CT scan evaluation.
Methods
and Materials: 30 patients (15 males, 15 females) underwent full-
body CT scan for oncological diseases. The mean radiation dose delivered
was 101.63 mGy. Three blood samples have been taken for analysis:
immediately before the emission of radi ation (T0), 15 minutes and 30 minutes
after the beginning of the exam (T1 = T0 +15 min, T2 = T0+ 30 min). Cell
preparations were afterwards examined with FACS (fluorescence-activated cell
sorting).
Results
At T1, in 90% of cases, we identified the presence of cell damage in
terms of increased expression of 3-H2 AX of about 27%. At T2, in 36% of the
samples we appreciated a reduction in the expression of 3-H2 AX compared to
T1, probably linked with activation of cellular repair mechanisms; in the
remaining 64% of cases, we found increasing expression of 3-H2 AX,
suggesting damage progression.
Conclusion
Already 15 minutes after in vivo ionizing radiation exposure, like
CT exams, a significant nuclear damage in terms of DNA DSBs is appreciable;
in some cases, it seems that the human organism activates in short-time
mechanisms of biological repair able to reduce this damage.
B-1030 15:12
Small animal imaging with a preclinical x-ray phase-contrast and dark-
field scanner
A. Yaroshenko
1, A. Velroyen1, M. Bech1, A. Tapfer1, M. Müller1, B. Pauwels2,
P. Bruyndonckx2, A. Sasov2, F. Pfeiffer1; 1Garching/DE, 2Kontich/BE
(
[email protected])
Purpose: The purpose of this study was to demonstrate that a compact small-
animal x-ray phase-contrast and dark-field scanner yields superior soft-tissue
contrast and complementary information, when compared to the conventional
absorption-based imaging.
Methods
and Materials: We developed a compact preclinical scanner that
acquires conventional x-ray absorption simultaneously with phase-contrast and
dark-field images. This is achieved by placing a three-grating interferometer in
the beam. This is the first scanner that has a grating interferometer
implemented on a rotating gantry. The scanner was used to acquire a CT scan
of an ex vivo 10-week-old C57BL/6N mouse, fixated in formalin. Subsequently,
a C57BL/6N in vivo mouse was imaged using the scanner in a radiography
mode. During image acquisition the mouse was breathing freely.
Results
The phase-contrast CT of the ex vivo mouse showed significantly
higher soft-tissue contrast than the conventional absorption CT, e.g. in the
abdomen region. On the acquired projection image of an in vivo mouse, the
lung is clearly visible in the dark-field modality. Furthermore, the trachea is
clearly visualised in phase-contrast, whereas bones are best visible in the
absorption modality.
Conclusion
It has been observed that dark-field radiography has a very high
potential for lung imaging, as the signal-to-noise ratio is much higher than in
other imaging modalities. Furthermore, it has been shown that the developed
rotating gantry is stable for CT acquisition. In fact, all ex vivo CT results
showed superiority of the x-ray phase-contrast imaging for biomedical
applications.
Author Disclosures:
B. Pauwels: Employee; Bruker microCT. P. Bruyndonckx: Employee; Bruker
microCT. A. Sasov: CEO; Bruker microCT.
B-1031 15:21
Automatic assessment of upper urinary tract clearance during the initial
phase of digital pyelography
I.S. Leichter, V. Neeman, E.Y. Panfil, O. Gleisner, R. Morag, M. Duvdevani;
Jerusalem/IL (
[email protected])
Purpose: Upper urinary-tract clearance, affected by kidney pathologies, is
currently estimated by visual monitoring of contrast-media clearance from the
renal pelvis in retrograde or antegrade pyelography. Since such estimation
involves high radiation dose and is very subjective, this study explores a new
computerised method for assessing quantitatively upper urinary-tract
clearance, using only images from the initial phase of pyelography.
Methods
and Materials: The computerised method is based on analyzing the
radio-density of the contrast-media in sequential pyelography images. 55
patients following PCNL and retrograde or antegrade pyelography were
studied. 18 of the patients experienced known kidney pathologies. Following
image normalisation by a novel phantom attached to the patient, the integrated
optical-density of the contrast-medi a in the renal pelvis was analysed
quantitatively in sequential images, to yield clearance curves. Significance of
differences was calculated by Pearson t-test.
Results
For all patients, the obtained clearance curves highly fitted
exponential regression and the relative clearance-rate per minute was
calculated. The mean clearance rate per minute for the pathologic cases
(7.78%) was significantly (p < 0.001) lower than for normal cases (50.45%).
Measurements showed that after the first 3 minutes of pyelography the relative
clearance of contrast-media was already significantly lower (p < 0.001) for
pathologic cases (19.5%) compared to normal cases (70.8%).
Conclusion
The mean clearance rate measured by the new method for
normal patients was about 6.5 times higher than of pathologic cases. The
differences in clearance-rate were already significant after the first 3 minutes of
pyelography, providing an accurate quantitative assessment with reduced
radiation dose.
14:00 - 15:30 Room N/O
Vascular
SS 1815
Carotid pathology evaluation
Moderators:
P. Almeida; Coimbra/PT
P. Minko; Homburg a.d. Saar/DE
B-1032 14:00
Atherosclerotic plaque texture from 3D carotid ultrasound improves
prediction of vascular events
A. van Engelen
1, T. Wannarong2, G. Parraga2, W.J. Niessen1, A. Fenster2,
J.D. Spence2, M. de Bruijne1; 1Rotterdam/NL, 2London, ON/CA
(
[email protected])
Purpose: To compare the predictive value of change in carotid ultrasound
derived plaque texture ( ,Texture), change in total plaque volume ( ,TPV), and
a combination of those two measures, for the occurrence of vascular events.
Methods
and Materials: 298 patients with carotid atherosclerosis were
scanned with 3D-US at baseline and after one year. Plaque volume and 376
measures of texture were measured in all plaque areas at both time points.
Patients were followed up to 5 years for occurrence of myocardial infarction,
TIA, stroke and death due to vascular causes. Sparse Cox Regression was
used to select the most predictive texture measures and to combine them into
one risk measure. Selection and combination of texture measures, and
combination with ,TPV, was performed in independent training sets using a
tenfold cross-validation to ensure unbiased results.
Results
Kaplan-Meier analysis showed improved predictive value for
,Texture and ,TPV combined (difference between tertiles: p < 0.001)
compared to ,Texture (p < 0.01) and ,TPV (p=0.039) individually. In Cox
regression, adjusted for 13 clinical parameters including age, sex, smoking
status, cholesterol, diabetes and previous events, ,Texture (HR=1.66,
p=0.012) and ,TPV (HR=1.47 per 100 mm3, p=0.001) were both significant
predictors of vascular events, with no oth er traditional risk factors being
significant.
Conclusion
Changes in plaque texture and in plaque volume are both
predictive of vascular events, and have high er power than more traditional risk
factors. Their combination improves predictive value, and therefore may be
relevant to include in the monitoring of patients and for risk stratification in
vascular disease.
S359
BA C D E F G
Monday
Author Disclosures:
A. van Engelen: Research/Grant Support; CTMM, the Center for Translational
Molecular Medicine, project Parisk grant 01C-202; the Dutch Heart Foundation;
the Erasmus Trustfund. J.D. Spence: Research/Grant Support; Heart & Stroke
Foundation of Canada (Ontario), grant number NA5912.
B-1033 14:09
Microvesicle protein CD14 levels reflect carotid intima-media thickness in
8-year-old children
A.L.M. Eikendal, H. den Ruijter, A.M.V. Evelein, G. Pasterkamp, I.E. Hoefer,
D.P.V. de Kleijn, T. Leiner, M.L. Bots, C.S.P.M. Uiterwaal; Utrecht/NL
(
[email protected])
Purpose: Atherosclerosis, a process that begins in childhood, develops over
decades and underlies the majority of cardiovascular events. In adults,
microvesicle (MV) proteins relate to atherosclerotic disease. However, little is
known about the relation of MV proteins with atherosclerosis in children. This
study evaluates the relation between levels of MV proteins CD14, Serpin F2,
Serpin G1 and cystatin C and vascular characteristics in children.
Methods
and Materials: In 8-year-old children of the ongoing Wheezing-
Illnesses-Studie-LEidsche-Rijn (WHISTLER) birth cohort, anthropometrics and
blood pressure were measured. Common carotid intima-media thickness
(CIMT), carotid distensibility and carotid elastic modulus were obtained non-
invasively. In 130 children, a fasting lipid spectrum was acquired and MVs
were isolated from plasma. MV protein levels of CD14, Serpin F2, Serpin G1
and cystatin C were measured using a multiplex assay. In a multivariable
model, we assessed the relationship between these MV proteins and vascular
characteristics.
Results
Of the MV proteins under study, CD14 levels were positively
associated with CIMT ( 2=4.09x10
-4, p=0.019). This association proved to be
dependent on total cholesterol levels (p=0 .049 for interaction). Only in children
who had low total cholesterol levels ( 4.4 mmol/L, mean of total), MV protein
CD14 levels were positively related with CIMT ( 2=4.98x10-4, p=0.024). There
were no significant associations between levels of MV proteins and
distensibility or elastic modulus.
Conclusion
In children with low total cholesterol levels, MV protein CD14
levels are positively related to the degree of CIMT. Therefore, MV protein
CD14 levels may be useful markers for atherosclerosis burden from childhood
onwards.
B-1034 14:18
Carotid plaque vulnerability: could contrast enhanced ultrasound play a
role in patient management?
M. la Torre, R. Iezzi, E. Antonuccio, M. Nestola, A. Guerra, L. Bonomo;
Rome/IT (
[email protected])
Purpose: To assess a relationship between CEUS and immuno-histological
evaluation of carotid artery "inflammatory-vulnerable plaque".
Methods
and Materials: 50 consecutive patients (18 symptomatic; 32
asymptomatic) referring to our Department in order to perform carotid
endarterectomy, were enrolled. Ultrasound examination was performed using
high-frequency (8-14MHZ) linear probe and a non-linear pulse inversion
technique during a double contrast media injection (Sonovue,2-4 ml; Bracco,
Italy). Two videotapes were recorded for every injection: early "dynamic" phase
and late "flash" phase, performed with 6 high mechanical index impulses.
Movies were evaluated in terms of intraplaque enhancement and proliferation
of adventitial vasa vasorum both qualitatively, on the basis of a 4-point scale,
and quantitavely, using Esaote Qontrast 4.0 software. After surgical resection,
plaque specimens were evaluated imm unohistologically in order to assess
neovascularisation. Qualitative and quanti tative evaluation were statistically
compared to immunohistological results, considered as gold standard.
Results
Qualitative CEUS evaluation obtained high statistical results when
compared to immunohistological results, wi th values of sensitivity, specificity,
positive predictive value (PPV), negative predictive value (NPV), and
diagnostic accuracy of 94%, 68%, 87%, 85% and 86%, respectively, which
became higher if considering only asymptomatic patient, with a NPV of 91%.
Nevertheless, quantitative software evaluation proved less effective and
couldn't reach similar results.
Conclusion
Carotid plaque enhancement assessed with CEUS well
correlates with histological density of neovessels, which is associated with
plaque vulnerability. CEUS may provide valuable information for plaque risk
stratification and may play a role in the indi cation to treatment of patients with
carotid stenoses, particularly in asymptomatic population.
B-1035 14:27
The relationship between the volume of carotid bodies assessed by
computed tomography angiography and cardiac autonomic function in
patients with essential hypertension
P. Jazwiec, R. Poreba, P. Gac, M. Poreba, T. Miszalski-Jamka, G. Mazur,
M. Sobieszczanska; Wroclaw/PL (
[email protected])
Purpose: Determine the relationship between the estimated volume of the
carotid bodies (V rCB+lCB) assessed by computed tomography angiography
(CTA) and the autonomic cardiac function in patients with essential
hypertension (EH).
Methods
and Materials: The study included 22 consecutive individuals with
diagnosed and treated pharmacologically EH. Estimated volume of each
carotid body (CB) was evaluated on the basis of scans obtained in the CTA of
carotid and vertebral arteries, using the formula: 4/3 F x transverse dimension
of CB in axial projection x CB longitudinal dimension in the axial projection x
CB craniocaudal dimension in the sagitt al/frontal projection. Autonomic cardiac
function was assessed using analysis of heart rate variability (HRV). Time
domain HRV parameters: mRR, SDNN, SDANN, SDNNi, rMSSD, pNN50 were
obtained.
Results
Mean values of rMSSD and pNN50 were significantly lower in
patients with hypertension with the values of V
rCB+lCBmedian, compared to the
group of hypertensive patients with the values of V rCB+lCB<median (rMSSD:
50.18±10.15 ms vs. 64.63 ±6.18 ms, p < 0.05; pNN50: 10.73 ±2.49 % vs.
13.27±4.01 %, p < 0.05). Statistically signific ant negative linear correlations
was demonstrated between V rCB+lCB and rMSSD and between V rCB+lCB and
pNN50 (r: -0.33, -0.48). Based on the regression analysis it has been shown
that the higher values of V rCB+lCB are an independent risk factor in HRV
reduction in patients with EH.
Conclusion
In patients with EH a relationship between the volume of CB
assessed by CTA of carotid and vertebral arteries and autonomic cardiac
function seems likely, especially in terms of parasympathetic component.
B-1036 14:36
T1- and T2-weighted SE carotid plaque imaging and contrast-enhanced
MR angiography in comparison with intravascular ultrasonography:
qualitative and quantitative assessment
P.T. Klimeczek, B. Kozierowski-Do ga, K. Dy!, U. Zaleska-Dorobisz, W. W;
Wroclaw/PL (
[email protected])
Purpose: The study aimed to assess in vivo quantitative and qualitative plaque
features on 1.5 T carotid MR imaging and CE-MRA in comparison with
standard-IVUS.
Methods
and Materials: 20 pts (age73 ±9yr,9females) with symptomatic
carotid stenosis 50%-90% initially detected in USG were enrolled. Patients
underwent carotid MRI and MRI carotid angiography one to two weeks before
conventional angiography with IVUS study and PCI. Patients were studied with
a whole-body MR imaging scanner (Aera, Siemens) using 4-channel phased-
array surface head and neck coil. MR pre-contrast images were obtained with
3-DTOF, inversion recovery pre-contrast T1, double inversion T2 and proton
density fat saturation (in plane resolution 0.7x0.7x2 mm). Carotid angiography
was obtained with bolus tracking method and study inversion recovery CE-T1
5 minutes after intravenous infusion of 0.2-mmol gadoteridolum/kg. MRI
images were transferred and analysed on commercially available software.
IVUS imaging was performed using Volcano Therapeutics
® EagleEye Gold
catheter and Volcano Therapeutics ®IVG3 OracleImaging System. Spearman
rank correlation and p value for 95% CI were calculated for measured
parameters.
Results
There was no statistical difference (p0.07) between pre-contrast MRI
(T1,T2 imaging) and IVUS calculations of maximal plaque area, minimal lumen
diameter, area, reference area, area and plaque volumen, stenosis
assessment. Low correlation rho 0.55 and p value > 0.11 were found in
measurements of CE angiography stenosis as compared with IVUS. The
overall high-signal intensity (PD imaging) and high-contrast enhancement
correlated with large complicated fibroatheroma (p < 0.01).
Conclusion
1. T1WI and T2WI are useful to quantitative assessment of
carotid plaque 2. CE angiography weakly correlated with IVUS stenosis
measurements 3. T1 contrast study and PD imaging could be useful for
detection of complicated and advanced plaques.
B-1037 14:45
Prevalence, distribution and outcome of patients with calcified nodules in
carotid arteries
K.J. Kutter, D.C. Saam, F. Schwarz, T. Saam, M.F. Reiser, A. Helck;
Munich/DE (
[email protected])
Purpose: Calcified nodules are responsible for up to 5% of coronary infarcts
and are therefore classified as a minor criteria of the "vulnerable"
atherosclerotic plaque. We sought to evaluate the prevalence, distribution and
outcome of patients with calcified nodules in the carotid arteries.
S360
BA C D E F G
Monday
Methods
and Materials: 108 consecutive patients (90 with unilateral
ischaemic stroke, 37 female) with carotid plaques 2 mm by duplex ultrasound
underwent a carotid black-blood 3 T-MRI with fat-saturated T1w-, PDw-, T2w-
and TOF images using dedicated surface coils. Based on previous histological
validation, calcified nodules were defined as distinct calcification with an
irregular, protruding, and convex luminal surface. Prevalence of calcified
nodules was determined in both common and internal carotid arteries in
consensus by two reviewers who were blinded to clinical information.
Results
In total, 18 calcified nodules in 13 distinct arteries of 12 distinct
patients were identified. Calcified nodules were more commonly found in the
common compared to the internal carotid artery (11 vs. 7), in asymptomatic
compared to symptomatic arteries (8.2 vs. 3.4%) and in arteries with 50%
compared to arteries with < 50% stenosis (10% vs. 5.3%); although all these
differences were not statistically si gnificant (P=0.34, 0.15 and 0.26,
respectively).
Conclusion
Calcified nodules were found in approx. 10% of patients with
carotid plaques 2 mm by duplex ultrasound. We were not able to establish an
association of calcified nodules and ischaemic symptoms, suggesting that
calcified nodules play a minor role in the pathogenesis of ischaemic stroke in
the carotid arteries.
B-1038 14:54
Quantitative x-ray phase-contrast Hounsfield units for the differentiation
of carotid atherosclerotic plaque components
T. Saam1, M. Willner2, F. Bamberg1, C. Habbel1, J. Herzen2, U. Schueller1,
A. Hipp2, F. Pfeiffer2, H. Hetterich1; 1Munich/DE,
2Garching/DE (
[email protected])
Purpose: Conventional CT can distinguish between soft, mixed and calcified
plaques but has difficulties to further differentiate soft plaques due to an
overlap in Hounsfield units of fibrous and lipid tissue. Phase-contrast imaging
is a novel x-ray-based imaging technique that relies on the x-ray phase-shift
rather than its absorption, yielding a high er contrast in biological soft tissue.
We sought to evaluate whether plaque components can be differentiated
based on their phase-contrast HU (HU-P), which can be calculated in analogy
to absorption-contrast HU.
Methods
and Materials: Four ex vivo human carotid arteries were imaged at a
laboratory-based set-up using a conventional x-ray tube (35 kV) and grating-
interferometer. Tomographic images were reconstructed with an effective pixel
size of 100 m and correlated with histopathology sections. Regions
corresponding to fibrous, lipid or calcifi ed tissue based on histopathology were
manually traced. Mean HU-P were calculated for all analysed regions.
Results
A total number of 80 cross-sections with 72 fibrous, 19 lipid and 24
calcified tissue containing regions we re assessed. Fibrous, lipid and calcified
tissues were associated with significant different mean HU-P (52.6 ±7.0,
21.0±9.8 and 371.5± 158.0, p < 0.001). Furthermore, there was no overlap of
HU-P between fibrous (range 44.9 - 63.3) and lipid tissue (3.1-30.1). Similarly,
no overlap of HU-P was observed between calcified tissue (range 174.4 -
593.7) and the other tissue components.
Conclusion
In an ex vivo experimental set-up grating-based phase contrast
CT can reliably differentiate between calci fied, fibrous and fatty tissue based
on quantitative HU-P, indicating its hi gh potential for improved assessment of
carotid atherosclerotic disease.
Author Disclosures:
T. Saam: Research/Grant Support; Diamed Medizintechnik. Speaker;
GlaxoSmithKline, MSD SHARP & DOHME Gmbh.
B-1039 15:03
Intra-individual comparison of carotid and femoral atherosclerotic plaque
features with in vivo MR plaque imaging
A. Helck1, N. Bianda2, G. Canton3, C. Yuan3, M.F. Reiser1, A. Gallino2,
R. Wyttenbach2, T. Saam1; 1Munich/DE, 2Bellinzona/CH, 3Seattle, WA/US
(
[email protected])
Purpose: To evaluate differences of plaque composition and morphology
within the same patient in different vascular beds using non-invasive MR-
plaque imaging.
Methods
and Materials: 28 patients (67.8± 7.4 years, 8 females) with high
Framingham general cardiovascular disease 10-year risk-score and mild-to-
moderate atherosclerosis were consecutively included in the study. All subjects
underwent dedicated MRI-plaque-imaging-protocol using TOF- and T1w- and
T2w-black-blood-sequences with fat suppression (1.5 T). The scan was
centered on the carotid bulb of the carotid and on the most stenotic lesion of
the femoral arteries, respectively. Plaques were classified according to the
American-Heart-Association lesion ty pe classification and area measurements
of lumen, wall and the major plaque components, such as calcification, necrotic
core and haemorrhage were determined in consensus by two blinded
reviewers using dedicated software. Plaque components were recorded as
maximum percentages of the wall area.
Results
Carotid arteries had larger maximum wall and smaller minimum
lumen areas (P < 0.001). Prevalence of lipid-rich AHA-lesion-type-V and
complicated AHA-lesion-type-VI with haemorrhage/thrombus/fibrous-cap
rupture was significantly higher in the carotid arteries compared to the femoral
arteries. Plaque composition as percentage of the vessel wall differed
significantly between carotid and femo ral arteries: Max. %necrotic core and
max. %haemorrhage were significantly higher in carotid arteries compared to
femoral arteries (P=0.001 and P=0.02, respectively). Max.%Calcification did
not differ significantly.
Conclusion
In vivo MRI is able to visualise differences in plaque composition
of distinct vascular beds within the same patient. More specifically, the plaque
phenotype and thus the extent of atherosclerosis differs within the same
patient across different vascular beds.
B-1040 15:12
Genetic and environmental effects on carotid flow velocities: an
international twin study
P. Lucatelli
1, A.D. Tarnoki2, D.L. Tarnoki2, F. Fanelli1, V. Berczi2, E. Medda1;
1Rome/IT, 2Budapest/HU (
[email protected])
Purpose: Altered carotid blood flow velocities (CFV) have a complex
Background
but the underlying genetic contribution is still unclear.We sought to
evaluate the influence of genetics, shared and unshared environmental
components on individual differences of CFV.
Methods
and Materials: 193 healthy twin pairs,126 monozygotic (MZ) and 67
dizygotic (DZ)(mean age 53 ±14 years)recruited in Italy, in the United States
and in Hungary underwent bilateral color-coded Doppler flow assessment of
the common carotid artery (CCA)and of the internal carotid artery (ICA)in order
to assess the peak systolic (PSV) an d end diastolic (EDV)velocities.Means of
bilateral CFV values were used in the analysis.
Results
Age- and country-adjusted intra-class correlations were higher in
monozygotic than in dizygotic pairs for mean PSV of the ICA indicating a
heritability of 63%. Unique environmental factors contributed to 37% of ICA
PSV.With regards to the mean PSV and EDV of the CCA, and EDV of the ICA,
heritability analysis indicated no discernible role for genetic components, while
the contributions of shared and unshared environmental factors ranged
between 56% and 63%, and between 37% and 44% adjusted for age and
country, respectively.ICA/CCA ratio was driven by unique environmental
factors (81-88%)with negligible heritability (0-12%).
Conclusion
Our study showed that the heritability of ICA PSV is moderate,
while the findings do not support heritability of other investigated CFV
values.Environmental effects account for a moderate to major portion of the
variance.These findings support the value of early ultrasound screening as well
as the prevention of modifiable environmental factors in case of altered carotid
flow-velocities.
B-1041 15:21
Carotid artery dissection in CT: does the colour improve the diagnostic
confidence of the readers?
L. Saba1, E. Raz2, P.P. Bassareo1, G.M. Argiolas1, J.S. Suri3, M. Piga1;
1Cagliari/IT, 2New York, NY/US, 3Roseville, CA/US (
[email protected])
Purpose: To evaluate if the use of chromatic analysis, instead of the use of
gray-scale, in the MDCTA study of carotid artery dissection (CAD) modify the
observer's diagnostic accuracy.
Methods
and Materials: One hundred patients (61 men; mean age, 51 years)
40 with and 60 without CAD, that underwent MDCTA formed the study cohort.
Patients from three different groups were included (patients with MR
confirmation of CAD, n = 40; patients with MR confirmation of CAD absence, n
= 20; patients that underwent MDCTA for suspected atherosclerosis, n = 40).
Four blinded observers with different level of expertise analysed the
randomised basal scan of the MDCTA dataset. ROC curve analysis, the Cohen
weighted test and sensitivity, specificity, PPV, NPV, accuracy, LR+ and LR-
were performed.
Results
The ROC curve analysis showed that for all observers the use of
chromatic-scale produced an improvement of the diagnostic confidence with
AUC values from 0.896 to 0.936; from 0.823 to 0.849; from 0.84 to 0.909 and
0.749 to 0.861 for expert, intermediate A, intermediate B and trainee
observers. In particular, the variation of diagnostic confidence (between the
AUC areas) for the trainee was statistically significant (p = 0.036). Also
accuracy, as well as sensitivity, specificity, PPV, NPV, LR+ and LR- were
better using the chromatic scale
Conclusion
Results of our study suggest that the use of chromatic scale
instead the classic gray-scale improves the diagnostic confidence of the
readers, in particular of the junior ones, by improving also the accuracy,
sensitivity and specificity.
S361
BA C D E F G
Monday
14:00 - 15:30 Conf. Room M3
Interventional Radiology
SS 1809
Embolisation including radioembolisation
Moderators:
J.I. Bilbao; Pamplona/ES
N. Ptohis; Athens/GR
B-1042 14:00
Yttrium-90 radioembolisation vs sorafenib for hepatocellular carcinoma:
a cohort study with a propensity score analysis
A. Cappelli, C. Mosconi, E. Giampalma, M. Renzulli, M. Galaverni,
A. Gramenzi, A. Granito, F. Trevisani, R. Golfieri; Bologna/IT
(
[email protected])
Purpose: Sorafenib and transarterial 90Y-radioembolisation (TARE) are
possible treatments for Barcelona Clinic Liver Cancer (BCLC) intermediate-
advanced stage hepatocellular carcinoma (HCC). No study directly comparing
sorafenib and TARE is currently available. This study compares patient
outcomes achieved with these therapies.
Methods
and Materials: This retrospective study evaluated 112 patients
treated with sorafenib and 73 with TARE. Selection criteria: Child-Pugh class
A/B, performance status 1, HCC unfit for effective therapies, no metastases
and previous systemic chemotherapy. Propensity analysis provided one-to-one
match between sorafenib and TARE patients for independent prognostic
factors.
Results
Seventy-four sorafenib (71 ±10 years, male 87%, BCLC B/C
53%/47%) and 63 TARE patients (66± 9 years, male 79%, BCLC B/C
41%/59%) were included in the analysis. Median overall survival was 14.4
months (95% CI: 4.3-24.5) in sorafenib and 13.2 months (6.1-20.2) in TARE
patients, with 1-, 2- and 3-year survival rates of 52.1%, 29.3% and 14.7%
versus 51.8%, 27.8% and 21.6%, respectively (P=0.959). Two TARE patients
underwent liver transplantation after successful downstaging. After the
propensity model had matched 32 patients of each group for median age,
tumour gross pathology and the independent prognostic factors (portal vein
thrombosis, performance status, Model for End Liver Disease), the median
survival was 13.1 months (1.2-25.9) in sorafenib and 11.2 months (6.7-15.7) in
TARE patients, with 1-, 2- and 3-year survival rates of 53.1%, 23.0% and
15.3% versus 44.7%, 19.0% and 9.5%, respectively (P=0.392).
Conclusion
In cirrhotic patients with intermediate-advanced or not-otherwise-
treatable HCC, sorafenib and TARE provide similar survivals. Down-staging
allowing liver transplantation only occurred after TARE.
B-1043 14:09
Safety of radioembolisation with 90Yttrium-microspheres depending on
coiling or no-coiling of aberrant vessels
P.M. Paprottka
1, A. Walter1, A. Haug1, C.G. Trumm1, P. Bartenstein1,
M.F. Reiser1, C. Zech2; 1Munich/DE,
2Basle/DE (
[email protected])
Purpose: To evaluate the safety of radioembolisation with 90Yttrium-
microspheres depending on coiling or no-coiling of aberrant vessels.
Methods
and Materials: The early and late toxicities of 400 radioembolisation
procedures were retrospectively analysed according to the National Cancer
Institute's Common Terminology Criteria for Adverse Events (CTCAE v3.0). In
200 procedures the aberrant vessels were coiled prior to radioembolisation and
in 200 procedures we chose a more peripheral position to treat the right or left
liver lobe.
Results
Except for one instance of treatment-associated cholecystitis (grade
4 toxicity) there were no acute or delayed toxicities according to the CTCAE
criteria higher than grade 2. No radiation-induced liver disease was noted.
There was no significant difference (p > 0.05) in acute or delayed toxicities
depending on actually recommended coiling of aberrant vessels prior to
treatment in comparison to choosing a peripheral treatment position.
Conclusion
Radioembolisation with 90Yttrium-microspheres is a safe and
effective treatment option. Performing of radioembolisation without coiling
aberrant vessels prior to treatment could be an alternative option for
experienced centers.
B-1044 14:18
Yttrium-90 radioembolisation for the treatment of unresectable liver
cancer or liver metastases from gastrointestinal system cancers: results
of a one-center study
Ö. Özgür, S. Gunduz, E. Alimoglu, M. Erkılıc, H.S. Bozcuk, H.T. Sindel;
Antalya/TR (
[email protected])
Purpose: To determine the effects of yttrium-90 (Y-90) resin microsphere
radioembolisation therapy on patients with unresectable liver cancer who do
not benefit from chemotherapy.
Methods
and Materials: Fifty-five patients underwent radioembolisation
therapy between 2010 and 2012 were included in the study. All of these
patients had unresectable primary or metastatic liver cancer originating from
the gastrointestinal tract. Three were excluded from the study after pre-
evaluation angiography. Thirteen (23.6%) of the remaining 52 patients had
hepatocellular carcinoma and 39 (76.4%) had metastatic liver cancer. Fifty-two
patients underwent Y-90 radioembolisation treatment. After the procedure,
clinical follow-up of each patient was retrospectively conducted using our
hospital's data processing programs. Each patient's response to the
administered treatment was evaluated using the Response Evaluation Criteria
in Solid Tumors (RECIST) and the overall probability of survival was displayed
graphically by the Kaplan-Meier method.
Results
Fifty-five patients underwent pre-evaluation angiography had their
extrahepatic branch embolised (46 gastroduodenal artery, 3 accessory right
gastric artery, 2 supraduodenal artery) for hepatic arterial isolation. Fifty-two of
them that were evaluated using gamma camera imaging with
macroaggregated albumin were determined to be suitable for treatment. After
Y-90 therapy, 47 patients were follow-up. While 57% of the patients responded
to treatment as clinical benefit, the disease progressed in 43%. The median
hepatic progression-free survival time of the patients was 3.4 months (95%
confidence interval (CI):1.4-5.3) and the overall survival time was 11.3 months
(95% ci:8.7-14.03).
Conclusion
This study emphasises that Y-90 resin microsphere
radioembolisation treatment is effective in patients with unresectable liver
cancer.
B-1045 14:27
Selective internal radiation therapy of hepatic tumours: is coiling of the
gastroduodenal artery always beneficial?
J. Schelhorn, J.M. Theysohn, J. Ertle, J.F. Schlaak, S. Müller, A. Bockisch,
T.C. Lauenstein; Essen/DE (
[email protected])
Purpose: To minimise the risk of extrahepati c 90-yttrium (90Y) deposition. the
gastroduodenal artery (GDA) is often coil embolised before SIRT.The aim of
this study was to assess the effect of GDA occlusion with regards to arterial
hepato intestinal collateralization (HIC).
Methods
and Materials: 606 patients were scheduled for SIRT between 2006
and 2012 at our hospital. Digital subtraction angiography (DSA) followed by
99m-technetium labelled human serum albumin microspheres (99mTc-HSAM)
administration and SPECT/CT was initially performed. Depending on vascular
anatomy and hepatic tumor load, GDA coil embolisation was considered. In
subsequent 99mTc-HSAM, rescans or the therapeutic DSA HIC and its
consequences for SIRT were analysed.
Results
In 86 of 606 patients (14%), the GDA was occluded. 22 of these 86
patients did not undergo SIRT due to the patients' clinical status or SIRT
contraindications. In 28 of the remaining 64 patients, newly apparent or
reopened HIC were seen either at the site of the proximal GDA ( n=21) or in the
periphery of the hepatic arteries ( n=7). In 25 of these 28 patients, the HIC
could be occluded or the catheter position could be changed achieving a safe
90Y application. However, due to the HIC in 3 of 28 patients SIRT was
regarded unsafe and was abandoned.
Conclusion
GDA occlusion may induce arterial hepato intestinal collaterals.
Although most of these collaterals do not impede 90Y administration, SIRT
may become unfeasible in specific occasions. Hence, we recommend
segmental or lobar SIRT instead of a whole liver approach with GDA coiling.
B-1046 14:36
Randomised comparison of SIRT and TACE for treatment of intermediate
stage HCC
M.B. Pitton, R. Kloeckner, G.M. Wirth, C. Ruckes, W. Eichhorn, M.A. Woerns,
A. Weinmann, G. Otto, C. Dueber;
Mainz/DE (
[email protected])
Purpose: To compare SIRT and DEB-TACE for treating intermediate stage
Hepatocellular Carcinoma (HCC).
Methods
and Materials: 24 patients with intermediate stage HCC were
randomised 1:1 for SIRT or DEB-TACE. In case of recurrence, SIRT was
allowed to be repeated once. TACE was repeated every 6 weeks until no
viable tumor was detected by MRI. Follow-up included contrast enhanced MRI
every 3 months.
S362
BA C D E F G
Monday
Results
There were no differences in terms of demographics and tumor load
between both groups. Progression-free survival (PFS) was 180 days for SIRT
and 216 days for TACE (Median, n.s). Time to progression (TTP) was of 371
days versus 336 days (n.s). and Overall survival (OS) was 592 days versus
788 days, respectively (n.s). Causes of death were liver failure (predominant in
SIRT group), tumor progression (predominant in TACE group), cardiovascular
events, and inconclusive.
Conclusion
There was no significant difference in PFS, TTP, and OS after
SIRT or TACE. SIRT presented a lower rate of tumor progression but a greater
rate of liver failure. This randomised pilot study might be used for sample size
calculations of future studies.
B-1047 14:45
Preoperative estimation of remnant liver function using contrast-
enhanced ratio following percutaneous transhepatic portal embolisation
on Gd-EOB-DTPA-enhanced MRI
Y. Sato1, S. Matsushima1, Y. Inaba1, H. Yamaura1, M. Kato1, T. Ishiguchi2;
1Nagoya/JP, 2Nagakute/JP (
[email protected])
Purpose: The indocyanine green plasma disappearance rate (ICG-K) of the
future remnant liver (ICG-Krem) might not provide accurate assessment for
estimating heterogeneous liver function owing to percutaneous transhepatic
portal embolisation (PTPE). The purpose of this study was to evaluate the
contrast-enhanced ratio in the hepato-biliary phase (Enhanced Ratio) on
gadoxetic acid disodium (GD-EOB-DTPA)-enhanced MR imaging as a
preoperative estimation of future remnant liver (FRL) function in patients
undergoing PTPE.
Methods
and Materials: In 53 patients, the correlation between ICG clearance
and Enhanced Ratio imaging was analysed as preoperative estimation for
hepatectomy (first analysis). Twenty-three of 53 patients underwent PTPE for
extended hepatectomy and Enhanced Ratio imaging as preoperative
estimation after PTPE was analysed (second analysis). Whole liver function
and FRL function were calculated on MR imaging as follows: Enhanced Ratio ×
total liver volume (Enhanced Ratio Index) and FRL Enhanced Ratio × FRL
volume (Rem Enhanced Ratio Index), respectively.
Results
ICG-K correlated with the Enhanced Ratio Index (coefficient 0.375, P
= 0.006), and ICG-Krem strongly correlated with the Rem Enhanced Ratio
Index (0.821, P < 0.001) at the first analysis. ICG-Krem and the Rem
Enhanced Ratio Index were significantly correlated after PTPE (0.597,
P < 0.003) at the second analysis. The rate of improvement from before PTPE
to after PTPE of the Rem Enhanced Ratio Index (48.6%) was significantly
higher than that of ICG-Krem (26.4%) (P < 0.05).
Conclusion
Enhanced ratio imaging can be used to estimate FRL function
after PTPE.
B-1048 14:54
Outcome of emergency trans-arterial embolisation of spontaneous
ruptured hepatocellular carcinoma with emphasis of angiography and CT
correlation
J.H.Y. Leung, R. Lee, S. Yu, J. Hui, J. Wong, H. Hung, D. Siu, T. Cheung,
C. Chu; Shatin/HK (
[email protected])
Purpose: To analyse the outcome of emergency trans-arterial embolisation
(TAE) of spontaneous ruptured hepatocellular carcinoma (HCC) and to
correlate the outcome with the angiographic and CT findings.
Methods
and Materials: A total 63 patients diagnosed with spontaneous
ruptured HCC and unstable hemodynamic status were treated with TAE
between Aug 2001 and Jan 2013. 50 males and 13 females with a mean age
of 56.8 (range 30-88) followed up for a mean time of 87 months (range 3-138)
were retrospectively analysed. The primary end-point was the technical
success of embolisation to the target vessel territory. The secondary end-
points were clinical successful rate of bleeding control within 30 days, early
death within 30 days and embolisation related complications. The angiographic
and CT findings were assessed and correlated with the early mortality.
Results
Embolisation was technically successful in 100% cases. The clinical
successful rate of bleeding control within 30 days was 97% (61/63). There
were 10 cases (16%) of self-limited post-embolisation syndrome. No
embolisation related complication, liver failure or treatment-related death
occurred. The early 30-day mortality rate was 38% while the overall median
survival was 8.75 months. Imaging (angiographic and CT) findings that were
associated with early 30-day mortality included large tumour size and partial
portal vein thrombosis. Surgical resecti on were possible in 11 patients with
cumulative survival significantly longer than that of patient managed with non-
operative treatment (p=0.04).
Conclusion
Emergency TAE is effective and well tolerated treatment for
hemostasis of ruptured HCC in patients with hemodynamically unstable
condition.
B-1049 15:03
Prostate artery embolisation: preliminary outcomes for symptomatic
benign prostate hyperplasia
K.J. Kowalik, J. Golzarian; Minneapolis, MN/US (
[email protected])
Purpose: This pilot project provides guidance for the clinical and logistical
feasibility of a larger study evaluating the safety and effectiveness of prostate
artery embolisation (PAE) as a treatment for benign prostate hyperplasia
(BPH). A multidisciplinary clinical team collaborated to develop a pilot study
protocol. BPH will affect the majority of men over age 60. Global quality of life
declines as BPH increases. Medical and surgical treatments may be ineffective
or unappealing to some.
Methods
and Materials: After urologic and imaging evaluation, 10 male BPH
patients age 60.6 -93.6 with prostate size 30-170 g (average 84.6) and avg.
max urinary flow rate 6.3 ml/sec had PAE. Clinical outcomes include IPSS
symptom scores, QOL, prostate size and max flow rate before and after PAE.
Results
There were no technical or device-related procedure complications. 2
patients had delayed episodes of acute urinary retention. Average IPSS scores
were 23.3 pre-PAE (range 11-29) and 15.3 (5-25) at 1-month post-PAE.
Average prostate size was 84.6 g pre-PAE (30-170) and 57.8 (37-71) at 1-
month post-PAE. 8 of 10 reported improved QOL at 1-month post-PAE. One
subject was lost to follow-up.
Conclusion
PAE is a clinically viable treatment for BPH. Although the 1-year
follow-up period is not quite completed, this series provides guidance for
development of larger PAE studies. The primary impediment to this study is
logistical. Patients who no longer have si gnificant prostate symptoms may lose
interest in follow-up encounters, and may need encouragement to continue
with imaging and urologic evaluations to provide data.
B-1050 15:12
Usage of uterine artery embolisation in obstetrical practice
D. Tazhibaev, B. Abishev; Astana/KZ (
[email protected])
Purpose: Use of uterine artery embolisation in obstetric bleeding and
evaluation of its efficiency.
Methods
and Materials: UAE as the prevention of obstetric bleeding in
adnation and previa of placenta was made on 54 patients. In 51 cases, UAE
were made on pregnant women in terms of 35-40 weeks in combination with
caesarean operation. In three cases, UAE were made after caesarean
operation to stop post operation uterine bleeding. UAE were done after
removal of foetus under the control of the fluoroscopy for preventing embolus
reflux into other vessels. Microspheres of 355-1000 micron were used for
occlusion of uterine artery.
Results
According to our data in 42 (82.3%) of the 51 observations after
bilateral UAE was noticed stable stop of uterine bleeding. In 8 (15.7%) of 51
observations was made amputation of uterus due to the low efficiency of UAE.
In one case, uterine amputation was done after bilateral UAE in 10-12 hours
because of uterine rebleeding. UAE on the early stage allowed to make certain
haemostasis in three cases with bleeding after caesarian operation and to save
reproductive organ. The blood-loss during surgery was 500-1200 ml.
Conclusion
As a result, UAE is quite effective method in preventing
measures of massive postoperative bleeding in obstetric practice in placenta
pathology. In addition, UAE is effective in stopping of uterine bleeding in
postoperative period.
B-1051 15:21
Uterine artery embolisation: long-term follow-up of leiomyoma
B. Abishev, D. Tazhibaev; Astana/KZ (
[email protected])
Purpose: To evaluate fibroid size using ultrasonography (US) and magnetic
resonance imaging (MRI) after uterine arteries embolisation (UAE) of
leiomyoma.
Methods
and Materials: From 2008 to 2013 September, 524 women with
symptomatic leiomyoma were treated by bilateral transcatheter UAE. The size
of particles depended on uterine arteries diameter and anastomosis between
uterine and ovary arteries. Mean age was 35.5 years (range - 20-52).
Results
The moderate reduction of leiomyoma's size was observed in one
month after UAE. Decrease of fibroid size determined by US - 18.4%, by MRI -
17.3%, in 1 month. Following reduction of fibroid's size was in 3 months by US
- 41%, by MRI - 42.7%, in 6 months by US - 58.4%, by MRI - 59.3%, in 12
months by US - 70.8%, by MRI - 72.7%. Doppler US-control showed blood flow
decrease during first month after UAE, in 3 months blood flow data were
restored in uterine arteries.
Conclusion
UAE is an effective, minimal-invasive kind of leiomyoma's
treatment. MRI and US are the modalities that can accurately estimate fibroid's
changes and blood flow in uterine arteries. The tendency of fibroid's shrinkage
after UAE is well-defined in period from 1M to 12M. After UAE the blood supply
of myometrium is restored according to US Doppler data in the period from 1M
to 3M.
S363
BA C D E F G
Monday
14:00 - 15:30 Board Room A
Radiographers
SS 1814
Issues in management and delivery of
modern imaging services
Moderators:
K. Kupcs; Riga/LV
L.A. Rainford; Dublin/IE
B-1052 14:00
Biocide aerosolisation: a new method for disinfection of radiology
department
R. Pintaric1, J. Matela1, Š. Pintari 2; 1Maribor/SI, 2Ljubljana/SI
(
[email protected])
Purpose: Hospitals are faced with increasingly resistant strains of
microorganisms. When it comes to disinfec tion, individual parts of electronic
equipment of angiology diagnostics such as patient couches of computer
tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be
very hard to disinfect. Disinfectants of choice are therefore expected to
possess properties such as rapid, residue-free action without any damaging
effect on the sensitive electronic eq uipment. This paper discusses the use of
the neutral electrolysed oxidising water (EOW) as a biocide for the disinfection
of diagnostic rooms and equipment.
Methods
and Materials: The CT and MRI rooms were aerosolised with EOW
using aerosolisation device. The presence of microorganisms before and after
the aerosolisation was recorded with the help of sedimentation and cyclone air
sampling. Total body count (TBC) was evaluated in absolute and log values.
Results
The number of microorganisms in hospital rooms was low as
expected. Nevertheless, a possible TBC reduction between 78.99-92.50% or
50.50-70.60% in log values was recorded. The research has shown that the
use of EOW for the air and hard-surface disinfection can considerably reduce
the presence of microorganisms and consequently the possibility of hospital
infections. It has also demonstrated that the sedimentation procedure is
insufficient for the TBC determination.
Conclusion
The use of biocide aerosolisation proved to be efficient and safe
in all applied ways. Also, no eventual damage to exposed devices or staff was
recorded.
B-1053 14:09
Service development by radiographer managers: a case study in MRI
service portfolio development through a formal research-based process
J. Castillo
1, C.J. Caruana2, P.S. Morgan3, C. Westbrook4; 1San Gwann/MT,
2Msida/MT, 3Nottingham/UK, 4Cambridge/UK (
[email protected])
Purpose: Ongoing service development is a key activity of the radiographer
manager. The purpose of the study was to develop a 2020 MRI service
portfolio using a formal research-based approach.
Methods
and Materials: A two-round Delphi process was conducted amongst
a panel of 11 MRI stakeholder experts which included policy makers, various
healthcare professions and patient advocates. Participants' views about the
current MRI service catalogue, service pipeline and desired 2020 MRI services
were initially elicited through semi-structured interviews which were transcribed
and subjected to thematic analysis. An online questionnaire consisting of 43
statements was developed for the second round of the Delphi. Level of
agreement was assessed via a Likert scale; with the agreement threshold set
at 80%.
Results
Key points of agreement were that the current MRI service catalogue
should be maintained, whilst new services such as guided breast biopsies,
imaging for oncological purposes (particularly staging of prostate cancer) and
enterography should be introduced. There was a lower level of consensus
regarding the introduction of breast screening, prostate MRI, 3 T MRI, and
MRI-PET fusion with reasons ranging from present low-funding levels to
inadequate physics expertise by radiol ogists, radiographers and medical
physicists.
Conclusion
The multi-stakeholder approach adopted ensured that the
proposed portfolio was successful in bridging customer needs, professional
aspirations and the organisation's strategic intent. It is suggested that
radiographer managers adopt such a formal research approach to service
development on a routine basis.
B-1054 14:18
Diagnostic value of ultrasound in the detection of rheumatoid arthritis
J. Castro Costa1, L.A. Torres1, J.L.M.O. Belo1, Ó. Tavares2, A. Saraiva2,
T. Patrão1; 1Castelo Branco/PT, 2Coimbra/PT (
[email protected])
Purpose: To compare the articular bone destruction evidenced in the
techniques of nephelometry, conventional radiology and ultrasonography.
Methods
and Materials: The collected sample universe consisted of 60
patients, in whom the rheumatoid arthritis was diagnosed after the realisation
of supplementary diagnosis exams, incl uding nephelometry, conventional
radiology and ultrasonography. The rheumatoid factor was quantified by the
nephelometry, whilst the number of bone erosions was quantified by
radiographies and echographies. The gathered data were analysed by a
statistic programme (SPSS version 19).
Results
Rheumatoid arthritis affects both sexes at any group of age, being
more common in women between 33 and 41 years old and men between 36
and 41 years old, in a ratio of 7:5. We obtained differences between the
number of bone erosions visualised in conventional radiology and the number
of bone erosions visualised in ultrasonography (P < 0.001). According to the
same test, more bone erosions were visualised by ultrasonography in 44
cases, and only in 3 of them more bone erosions were visualised by
conventional radiology technique, whilst in the remaining 13 the same number
of bone erosions was visualised in both techniques.
Conclusion
Ultrasound is a diagnostic technique that can be used as first line
examination in the detection of rheumatoid arthritis, since it uses no ionising
radiation and detects a greater number of bone erosions, when compared with
conventional radiology.
B-1055 14:27
The impact of real time active dosimetry monitoring during endoscopic
retrograde cholangiopancreatography
P.M.N. Mendes, T.A.R. Laranjeiro, G. Paulo, J. Santos; Coimbra/PT
(
[email protected])
Purpose: Evaluation of the occupational exposure and analysis of the impact
of the use of real time active dosimetry monitoring during endoscopic
retrograde cholangiopancreatography (ERCP).
Methods
and Materials: Data of staff exposure was collected during 55 ERCP
procedures in three separate phases using Raysafe i2 equipment. In phase 1
an active dosimeter was used under the apron; in the phase 2 the dosimeter
was above the apron and in phase 3 Raysafe i2 monitor was visible for staff
and the dosimeter was used above the apron. Fluoroscopy time was also
recorded.
Results
The gastroenterologist and the nurse were the professionals with
highest exposure, 6.78 Sv and 7.63 Sv per procedure. The use of lead apron
protection allows the average dose decrease 77%. When showing monitor with
real time exposure values the average reduction was 44% to 71% due to
behaviour alterations.
Conclusion
The values of occupational exposure for ERCP are similar to the
ones found in the literature. All the professionals were informed about the
importance of their positioning in the room during the procedure, with the help
of real time exposure monitoring. Personal protection and real time dose
monitoring are important tools for decreasing occupational exposure.
B-1056 14:36
Is it economically justifiable to let sonographers perform diagnostic
ultrasound examination in the upper abdomen? A cost/benefit analyse
from a hospital cluster in Norway
K.G. Vikestad; Oslo/NO (
[email protected])
Purpose: A scientific study from Norway concluded in 2011 that sonographers
are qualified to perform ultrasound examinations of upper abdomen equal to
radiologists. This is a cost/benefit analyse to explore whether it's justifiable to
use sonographers to perform diagnostic ultrasound in the upper abdomen.
Methods
and Materials: A cost/benefit analyse where a developed form
where used and contained variables as salary, time spent performing reports
by the radiologists, time spent and frequency of the sonographers need for
assistance by the radiologists, time spent and frequency of examinations
where radiologists had to take over the examinations because of the lack of
sonographers competence. The form also included a comparison of all the
examinations each sonographer made independently, the new tasks that the
radiologists find time to do in their sav ed time, the change of waiting time for
ultrasound examinations and change of waiting time of other radiology
examinations.
Results
The radiologists' have 36 or 17 hours saved time per week for other
tasks as a consequence of using the sonographers to perform all ultrasound
examinations in upper abdomen independently. The waiting list for ultrasound
examinations of upper abdomen is reduced.
Conclusion
The findings in this study shows that the waiting time is reduced
and the radiologists have saved time to perform more examinations with
S364
BA C D E F G
Monday
advanced diagnostic and CT, MRI and conventional x-ray examinations. This
study concludes that from a society perspective the benefits are documented,
depending on that the society will invest in the sonographer's education.
B-1057 14:45
Assessment of psychosocial risks faced by radiographers in Portugal
using the Copenhagen psychosocial questionnaire
J.M. Saude; Vila Nova de Gaia/PT (
[email protected])
Purpose: The economic recession and the development of new forms of
organisation in health institutions asso ciated with changes in the employment
relationship between health workers and employers brings inevitable
consequences in psychosocial risks exposures. The aim of the study was to
test an instrument for assessing psychosocial risk in radiographers and
examine psychosocial risk factors.
Methods
and Materials: We conducted a cross-sectional study design based
on Copenhagen Psychosocial Questionnai re (short version), completed by 329
radiographers.Sociodemographic and employment characteristics of the
participants were also collected. The original structure of the questionnaire was
accepted and the internal consistency of each scale was inspected. To assess
the internal consistency was used Cronbach's ' for the different scales. It was
considered that the value '> 0.70 as a criterion for a satisfactory internal
consistency. A descriptive correlation design is also being made to identify
interrelationships between psychosocial risk and workplace environment.
Results
Of the 8 work psychosocial workplace scales of the COPSOQ's short
version, 6 showed a satisfactory internal consistency ( '> 0.70). The scale
"Demands at work" ( '= 0.648) is below that value and the scale "Health in
general" has only one item. Further results are expected from the descriptive
correlation analysis.
Conclusion
The version of the "Copenhagen Psychosocial Questionnaire"
(COPSOQ) "presented appears to be a valid instrument measure the
psychosocial work environment of radiographers. Further conclusions are
expected from the descriptive correlation analysis.
B-1058 14:54
Setting standards for an MRI unit in Malta: a study in establishing image
quality criteria for MRI of the knee joint
S. Attard Mifsud, J. Castillo, F. Zarb; Msida/MT (
[email protected])
Purpose: The concept of quality criteria was introduced by the Commission of
the European Communities (CEC) for most imaging modalities. Despite the
complexity of MRI procedures, to date, there are no established image quality
criteria for MRI. The purpose of the study was to develop MRI quality criteria
for examinations of the knee using a formal research approach.
Methods
and Materials: A list of image quality criteria was developed
following a review of related literature. Potential anatomical structures were
identified, after which content validity was performed by a musculoskeletal
radiologist and an orthopedic specialist. Ten pathology free previously reported
MR knee examinations, performed on a GE 1.5 Tesla unit at the local general
hospital (Malta), each consisting of 3-pl anar fat-suppressed proton density fast
spin echo sequences were evaluated by radiographers. Visual grading analysis
was utilised to rate the extent of visibility of each anatomical structure.
Results
Key findings indicate that the current protocol fulfills the developed
image quality criteria. The importance of 3-planar imaging and the benefits of
tailored protocols which highlight the anatomical structures under investigation
therefore contributing to diagnostic accuracy were among the results emerging
after implementation of these criteria in the clinical setting.
Conclusion
Image quality criteria for MRI knee was established which will
guide the development of other MRI protocols. It is suggested that CEC
introduce image quality criteria for MRI to harmonize this complex mode of
imaging thus also providing a standard of patient care across departments.
B-1059 15:03
Kinematic X-ray imaging of the hip joint for patients after hip resurfacing
arthroplasty and total hip arthroplasty
H. Kawashima, Y. Kajino, T. Kabata, Y. Matsuura, H. Tsuchiya, S. Sanada;
Kanazawa/JP (
[email protected])
Purpose: This study aimed to evaluate the usefulness of dynamic radiographs
using a dynamic flat-panel detector (FPD) system for patients after hip
resurfacing arthroplasty (HRA) and total hip arthroplasty (THA).
Methods
and Materials: A total of 27 patients who underwent HRA for 34 hips
and 6 patients who underwent THA for 6 hips were included in this study.
Sequential images of active and passive fl exion in a 45-degree semi-lateral
position and active abduction in a supine position were obtained using the FPD
system. We examined the imaging findings of impingement between the
acetabular component and femoral neck along with cooperative motion at
maximal exercise; moreover the central component coordinate of the
acetabulum side and femoral head side was measured.
Results
Among the HRA patients, impingement was detected in 20 hips
(60%) during flexion and in 2 hips (6%) during abduction. There were no
findings of subluxation between the acetabular and femoral components after
impingement, but cooperative motion of lumbar and pelvic flexion did occur. In
contrast, subluxation was detected during passive flexion in a patient with THA
who experienced pain during deep flexion.
Conclusion
We investigated detailed postoperative kinematics of the hip in
patients after HRA and THA using a dynamic FPD system. This imaging
Method
facilitated assessments of impingement and cooperative motion, and it
can be possibly used for patient lifestyle guidance.
B-1060 15:12
Integrating ultrasound guided MR arthrography in an outpatient institute -
the radiographers' role
G. Biró, D. Kovács, Z. Gyevnár, C. Vandulek, I. Repa; Kaposvár/HU
(
[email protected])
Purpose: MR arthrography is widely accepted as a diagnostic procedure
performed on various joints. Its role is vital in examinations of the shoulder,
evaluating rotator cuff tears, capsulolabral complex, rotator interval,
glenohumeral ligaments and in certain cases after surgery. As MR
arthrography is an invasive examination, including it as a routine examination
in an outpatient may be a challenge in many ways - it requires considerate
patient, equipment and last but not least, time management - a perfect
'challenge' for a radiographer.
Methods
and Materials: Prior to the injection of contrast medium (gadolinium)
we perform a native MR scan of the selected joint. Afterwards, with the help of
ultrasound guidance (US) we inject 0.1 ml Gd and 10 ml iodine contrast
medium mixed with 10 ml saline into the joint. Through the preliminary
examinations we aimed to optimise the scanning protocols and examination
times. Patient preparation, coil changes etc. were standardised in order to work
out a smooth time management profile for MR arthrography.
Results
US guided MR arthrography was introduced in our diagnostic
portfolio without noticeable delays for patients and referring clinicians.
Radiographers have a key role not only in performing the examinations, but in
the patient management phase starting with the arrival of the referral and
ending with the finalised medical report.
Conclusion
Through careful planning and mindful time and equipment
management, the radiographers contribute to the succesful integration of US
guided MR arthrography even in an outpatient institute running with a tight
schedule.
B-1061 15:21
Self-assessment of clinical image quality in plain radiography: an
evidence-based practice for radiographers
N. Kärnä
1, U.-M. Aakula1, E. Metsälä2; 1Hämeenlinna/FI, 2Helsinki/FI
(
[email protected])
Purpose: To carry out the self-assessment of clinical image quality in plain
radiography of adult patient's lungs and knee according to best practice.
Methods
and Materials: This master's thesis comprised an applied systematic
literature review and a study, performed in 2012-2013, which combined a
qualitative and quantitative approach. The first stage was to develop an
evidence-based best practice for self-assessment of clinical image quality in
Kanta-Häme Central Hospital. The content of 19 articles and 151 pages of self-
assessment documents and 28 pages of transcribed interviews from three co-
operative organisations were analysed for this purpose. The frame for the
analysis was constructed from the literature and comprised three main
categories: planning and preparation, execution and evaluation. The pilot study
of the developed best practice was quantitative. Radiographers and one
radiologist from Kanta-Häme Central Hospital used an electronic survey to
perform a retrospective self-assessment of radiographs. The assessors'
experiences of this self-assessment were examined at the end of the survey.
Results
Very little evidence-based data was found and there seems to be a
lack of strong evidence. Practices in self-assessment of clinical image quality in
plain radiography were diverse. The de scription of self-assessed image quality
and assessors' experiences of the pilot study are discussed.
Conclusion
There is a need for local, national and global standards for the
practice of self-assessment of clinical image quality in plain radiography. These
standards could enhance the implementation of systematic and regular self-
assessment of clinical image quality. The role of radiographers in self-
assessment could be strengthened.
S365
BA C D E F G
Monday
14:00 - 15:30 Room P
Molecular Imaging
SS 1806
Clinical and experimental studies
Moderators:
I. Carrió; Barcelona/ES
T. Lammers; Aachen/DE
B-1062 14:00
Correlation of biological characteristics with metabolic information on
11C-methionine PET in primary brain tumours
E. Lopci, L. Bello, F. Raneri, M. Riva, M. Rodari, A. Chiti; Rozzano/IT
(
[email protected])
Purpose: In this study we aimed assessing the relation between biological
data and metabolic information as determined by 11C-methionine PET (MET-
PET) in patients affected by primary brain tumour and eligible for surgical
resection.
Methods
and Materials: Overall, we enrolled 54 consecutive patients
(M:F=34:20; mean age 45years) affected by pathologically proven gliomas and
referred to our Institution for primary surgery. All patients underwent MET-PET
and in all cases semi-quantitative analyses were obtained by taking into
consideration SUVmax, SUVratio, and Metabolic Tumour Burden
(MTB=metabolic tumour volume x SUVmean). MET-PET data were then
correlated with biological information including WHO grade/MIB1, isocitrate
dehydrogenase 1 gene (IDH1) mutation, 1p/19q co-deletion and O6-
methylguanine-DNA methyltransferase (MGMT) promoter methylation.
Results
We analysed 23 low-grade gliomas (LGG: grade II), and 31 high-
grade gliomas (HGG: 16 grade III and 15 grade IV). Based on semi-
quantitative analyses, we determined a statistically significant correlation
between SUVmax, SUVratio and MTB with tumour grading (p 2.8, SUVratio > 2.08 and MTB > 6.63. A statistically
significant correlation was found also between tumour uptake and IDH1
mutation, expressed in patients with lower SUVmax (p=0.003) and SUVratio
(p=0.002). The correlation was not confirmed for MTB, tumour grade/MIB1 and
IDH1 mutation, 1p/19q co-deletion or MGMT methylation.
Conclusion
Metabolic information obtained by MET-PET significantly
correlates with histological grading in primary brain tumours. Among other
biological characteristic s, also IDH1 mutation resulted correlated to tumour
uptake, with a prevailing expression in gliomas with lower SUVmax and
SUVratio, suggesting a better prognosis in these cases.
B-1063 14:09
Comparison of PET/CT using 11C-choline and 11C-methionine for
differential diagnosis of gliomas
Y. Ilyushchenko, A. Panfilenko, L. Tyutin, N. Kostenikov, A. Stanzhevskiy;
St. Petersburg/RU (
[email protected])
Purpose: To compare possibilities of PET with 11C-Choline (CHOL) and
(MET) in the differential diagnosis of gliomas.
Methods
and Materials: 24 patients with brain tumors (9 cases of
glioblastoma, 4 - anaplastic astrocyto ma, 6 patients with low grade gliomas
and 5 cases of anaplastic oligodendroglioma) were examined by MET and
CHOL PET-CT. The standardised uptake values of brain tumors and the T/NT
ratios were determined. Histological veri fication of PET findings was carried out
in all cases.
Results
The mean CHOL and MET T/NT ratios in glioblastomas were found
to be higher than those in anaplastic astrocytomas (mean ±SD: 11.0 ± 3.5 and
2.9 ± 1.07 versus 4.9 ± 2.29 and 1.92 ± 0.33 correspondently, p < 0.05). Low
grade gliomas showed significantly lowe r tracer accumulation than the malign
astrocytomas in both CHOL and MET studies (2.14 ± 1.08 and 1.5 ± 0.85
correspondently, p < 0.05). The CHOL T/N ratio in anaplastic
oligodendrogliomas was significantly higher than that in astrocytomas of the
same grade (7.82 ± 1.47 versus 4.9 ± 1.07, p < 0.05).
Conclusion
CHOL PET can distinguish between malignant and benign
gliomas and may be useful in differential diagnosis of anaplastic astrocytomas
and ologodendrogliomas.
B-1064 14:18
Simultaneous [18 F] FDG PET/MRI in patients with tumours of the head
and neck region: initial results
A. Wetter, F. Nensa, K. Nassenstein, T. Schlosser, T.C. Lauenstein,
M. Forsting, M. Schlamann, M. Ruhlmann;
Essen/DE (
[email protected])
Purpose: To evaluate simultaneous [18 F] FDG PET/MRI in patients with
tumours of the head and neck region regarding image quality and standardised
uptake values (SUVs).
Methods
and Materials: Twenty-two patients with tumours of the head and
neck region (squamous cell carcinoma: n=17, Adeno-CUP: n=3, adenoidcystic
carcinoma: n=2) were examined with simultaneous [18 F] FDG PET-MRI. MR
image quality and PET image quality of the PET/MRI scanner were assessed.
SUVs were quantitatively analysed by measuring and comparing SUVmax
between PET/MRI and PET/CT.
Results
Simultaneous acquisition of MRI and PET data were possible in all
patients without artefacts. Quality of MR images and PET images was judged
to be good or very good, there was no difference of PET image quality
between PET/MRI and PET/CT. The number of detected lesions was equal in
PET/MRI and PET/CT. The SUVmax of squamous cell carcinomas was 11.92
(± 6.89) for primary tumours in PET/MRI and 9.54 ( ± 4.05) in PET/CT (p=
0.048). SUVmax of lymph node metastases of squamous cell carcinomas was
7.83 (± 6.76) in PET/MRI and 6.38 ( ± 4.71) in PET/CT (p= 0.0064).
Conclusion
Simultaneous [18 F] PET/MRI in patients with tumours of the
head and neck region is feasible for routine clinical use. PET image quality of
PET/MRI and PET/CT is comparable. Differences of SUVmax between
PET/CT and PET/MRI might be explained by biokinetics of [18 F] FDG and
differences in attenuation correction of PET/MRI and PET/CT.
B-1065 14:27
Assessment of bone metastases in whole-body [18 F]FDG PET/MRI:
comparison to PET/CT
K. Beiderwellen
1, M. Huebner1, P. Heusch2, J. Grueneisen1, V. Hartung1,
F. Nensa1, H. Kuehl1, L. Umutlu1, T.C. Lauenstein1; 1Essen/DE,
2Düsseldorf/DE (
[email protected])
Purpose: To compare the diagnostic value of simultaneous [18 F]FDG
PET/MRI with [18 F]FDG PET/CT for the assessment of bone lesions in
oncologic patients.
Methods
and Materials: 67 patients (28 women, 39 men, age 56 ±13 years)
with solid tumors scheduled for a PET/CT with [18 F]FDG were enrolled for a
subsequent whole body contrast enhanced PET/MRI with an integrated
scanner. The datasets (PET/CT, PET/MRI) were rated by two readers with
regard to bone lesion conspicuity (4-poi nt ordinal scale, 0: not visible - 3: high
contrast) and diagnostic confidence (5-point ordinal scale; 1: certainly benign;
2: rather benign; 3: indeterminate; 4: rather malignant; 5: certainly malignant).
Median scores were compared using Wilcoxon's rank sum test. A consensus
reading based on prior examinations, PET/CT, PET/MR as well as a clinical
follow-up of 213±84 days served as standard of reference.
Results
Bone metastases were present in 10 patients (12%), benign bone
lesions in 15 patients (22%) and no osseous lesions in 42 (63%) patients. 45
out of 48 bone metastases (94%) were correctly identified by PET/CT, whereas
a correct identification of all bone metastases was possible based on PET/MRI.
Lesion conspicuity for metastases was high for both modalities with
significantly higher results using PET/MRI (p < 0.05). Diagnostic confidence in
metastases was high for both modalities as well, yet without any significant
difference. In contrast, for benign lesions conspicuity was significantly higher
on PET/CT (p < 0.05).
Conclusion
Integrated PET/MRI with [18 F]FDG shows a high potential in the
assessment of bone metastases and might serve as valuable alternative to
PET/CT.
Author Disclosures:
H. Kuehl: Speaker; Siemens Healthcare.
B-1066 14:36
Quantitative evaluation of bone metastases from prostate cancer with
simultaneous (18 F) choline PET/MRI: combined SUV and ADC analysis
A. Wetter, C. Lipponer, F. Nensa, T. Schlosser, T. Pöppel, T.C. Lauenstein,
J. Nagarajah; Essen/DE (
[email protected])
Purpose: Quantitative analysis of bone metastasis from prostate cancer with
correlation of apparent diffusion coefficients (ADC) and standardised uptake
values (SUVs).
Methods
and Materials: 67 patients with biopsy proven prostate cancer or
suspected recurrent prostate cancer were examined with simultaneous 18 F
PET/MRI. In 11 patients, altogether 32 PET positive bone metastases could be
identified that were located in the fi eld-of-view of the DWI-sequence. Region-
of-interest (ROI) analyses were performed to measure the average and
minimal ADCs and to assess maximum and mean SUVs of every bone lesion.
S366
BA C D E F G
Monday
Correlations between maximum and mean SUVs and average and minimal
ADCs were calculated.
Results
The SUVmax of all lesions was 5.5 ± 3.13 (mean ± SD). The
SUVmean was 1.75 ± 0.91. The average ADC (ADCaver) of all lesions was
666.45 ± 133.18 x 10-3 mm2/s. The minimal ADC (ADCmin) of all lesions was
564.24 ± 135.19 x 10-3 mm2/s. There was a moderate but significant inverse
correlation of SUVmax vs. ADCaver with a correlation coefficient of -0.4 (p =
0.02). There was also a significant inverse correlation of SUVmax vs. ADCmin
with r = -0.41 (p = 0.02).
Conclusion
Our results demonstrate a moderate but significant inverse
correlation between increased choline metabolism and ADC values of bone
metastases from prostate cancer. There is a possible complementary value of
DWI and choline PET for further characterisation of bone lesions in prostate
cancer patients. Further research on a multimodality approach using
simultaneous PET/MRI in bone metastases of prostate cancer seems to be
justified.
B-1067 14:45
Role of (18)F-sodium fluoride PET/CT in characterising osteoblastic
prostate cancer skeletal metastases
L. Nardo, M. Kretzschmar, S. Lee, C. Schreck, J. Slater, R. Hawkins,
M.J. Hernandez Pampaloni; San Francisco, CA/US (
[email protected])
Purpose: To evaluate the diagnostic values of 18 F-sodium fluoride (NaF)
positron emission tomography/computed tomography (PET/CT) imaging to
characterise osteoblastic prostate cancer skeletal metastases and to
distinguish them from benign processes.
Methods
and Materials: One hundred and ten patients (56-82 y.o., mean age
69 yrs) with biopsy proven adenocarcinoma of the prostate underwent
standard PET/CT imaging from vertex to toes approximately 45-60 minutes
after the intravenous administration of 370 ±37 MBq of 18NaF. Gleason
grading, serum prostate specific antigen levels (PSA), radiotherapy (RT),
hormone, surgical or chemotherapy treatments were recorded. One spine
lesion and one pelvic lesion were selected as index lesion per subject, and the
maximum standardised uptake values (SUV (max)) were calculated as a
semiquantitative surrogate measure for osteoblastic activity.
Results
The SUV (max) of metastasis was significantly higher than chronic
degenerative disease (p < 0.001). In those who did not undergo any treatment,
the SUVmax was not significantly different between pelvis and spine
metastasis (p=0.19).No statistical difference was found in SUV max between
subgroups separated by Gleason grading, serum PSA levels or TNM staging.
The SUV (max) of pelvic metastasis was significantly lower in patient status
post radiation therapy (p=0.049). The SUV (max) of both pelvic and spine
metastasis were not significantly lower in patients treated with antiandrogen.
However, a trend characterised by lower SUV max values was
demonstrated (p=0.08).
Conclusion
Our preliminary data suggests that semiquantitative
measurements of 18NaF activity with PET imaging can be useful in detection
of active skeletal metastasis in patients with prostate adenocarcinoma.
Importantly,18NaF PET imaging can accurately distinguish between benign
chronic degenerative changes and metastatic involvement.
B-1068 14:54
The impact of F18 choline PET/CT in the biochemical relapse of prostate
carcinoma: a retrospective analysis in a large collective
M. Pixberg, M.K. Pixberg, A. Zöllich, J. Müller-Hübenthal;
Cologne/DE (
[email protected])
Purpose: Relapse in prostate cancer after 10 years occurs in 20-50% of
surgically treated and in 30-40% of radiated patients with increased PSA. An
early differentiation between local relapse and systemic progression is
important, as in local relapse further curative therapy is possible. In case of
local disease, focused therapy such as radiation can delay hormone therapy.
Aim of this retrospective study is to analyse the impact of F18 Choline PET/CT
in relapse diagnosis of primarily successfully treated prostate carcinoma.
Methods
and Materials: Between 2007 and 2013, we analysed 196
investigations in 165 patients. Some patients had more than one relapse.
Patients with unsuccessful primary therapy and patients under hormone
therapy were excluded.
Results
Recurrence in the prostate fossa was found in 15% of cases, PSA
range 0.88 - 13, mean 4.54. Local lymph nodes were involved in 15% of cases,
PSA range 0.21 - 27, mean 3.7. Distant metastases were detected in 54% of
cases, PSA range 0.1 - 75.5, mean 5.18. No correlation was found in 16% of
cases, PSA range 0.02 - 13.14, mean 2.6. In 18 cases therapy was confirmed
by the PET/CT result. In 42 cases therapy strategy changed and in 5 cases
intention (curative/palliative) changed.
Conclusion
Choline PET/CT is valuable for identification of biochemical
relapse in cancer of the prostate and can find potentially curable cases. A
correlation can be identified even for low PSA concentrations of 13neg/ml some cases showed no
metabolical or morphological correlation.
B-1069 15:03
Hybrid 18 F-fluoride PET and MR imaging of the spine - a pilot study and
comparison of signals in patients with axial spondyloarthritis
C. Buchbender1, X. Baraliakos2, B. Ostendorf1, P. Heusch1, V. Hartung3,
K. Beiderwellen3, J. Braun2, G. Antoch1; 1Düsseldorf/DE, 2Herne/DE,
3Essen/DE (
[email protected])
Purpose: This study was performed as a pilot study on simultaneous 18 F-F-
PET/MRI of the spine in patients with axial spondyloarthritis (axSpA). PET/MRI
data were compared to MRI alone in order to evaluate whether 18 F-F-PET
provides additional information to MRI alone.
Methods
and Materials: In 11 axSpA patients, median age 39 years, disease
duration range 0.5-10 years, mean Bath ank ylosing spondylitis disease activity
index 5.3, 18 F-F- PET/MRI was performed 40 minutes after injection of a
mean dose of 157 MBq Fluoride using a hybrid whole-body PET/MRI scanner.
MRI data alone and fused 18 F-F- PET/MRI data sets were scored by two
blinded readers using the Berlin MRI score and by recording inflammatory PET
and MRI lesions on a vertebral edge (VE) level.
Results
Acquisition of whole-spine 18 F-F PET/MRI scans was successful in
all patients. The mean Berlin MRI score was 6.8 (range 0 - 31). Inflammatory
findings were consistent on both, MRI and 18 F-F-PET/MRI, in 90% of the
involved sites. In the remaining 10 %, focal 18 F-F-uptake without correlating
MRI pathology was detected. Current evaluations are aimed at characterising
these discrepant findings. At presentation we are going to present data on the
clinical relevance of the above named discrepancies between 18 F-F-
PET/MRI and MRI alone.
Conclusion
18 F-F- PET/MRI of the spine provides additional metabolic
information on inflammatory bone lesions in axSPA patients compared to MRI
alone. The clinical relevance of these additional findings is currently under
investigation.
B-1070 15:12
Assessment of 68Ga DOTATOC uptake in neuroendocrine cancer patients
undergoing PRRT to improve therapeutic stratification - a retrospective
response analysis
M. Stefanova
1, C. Kratochwil1, A. Afshar-Oromieh1, E. Mavriopoulou1, W. Mier1,
L.H. Schwartz2, U. Haberkorn1, F.L. Giesel1; 1Heidelberg/DE, 2New York,
PR/US (
[email protected])
Purpose: The goal of our investigation was to assess the somatostatin
receptor (SSR2) expression by determining SUVmax in the liver metastases
that will be most beneficial for patients with neuroendocrine tumours (NETs)
undergoing peptide-related radionuclide therapy (PRRT).
Methods
and Materials: 30 patients with 60 hepatic metastases of NETs were
evaluated in the retrospective study. Patients were divided into responders and
non-responders according to structural lesion changes. The response was
determined on a lesion-by-lesion basis evaluating morphological changes in
tumour size between baseline and follow-up CE-CT after three cycles of PRRT.
SSR2-expression of liver metastases in both groups was assessed at baseline
[SUV maximum (SUVmax), metastases-to-spleen SUV ratio (SUVm/s) and
metastases-to-liver SUV ratio (SUVm/l)].
Results
There was a statistically signifi cant difference between the mean
SUVmax of morphologically non-responders vs. responders prior PRRT in the
initial
68Ga DOTATOC PET/CT. The mean SUVm/s (1.20 ±0.37 vs.1.90 ±0.45,
p < 0.05) and mean SUVm/l (3.15 ±0.53 vs.4.97 ±0.62, p=0.0003) also showed
statistically significant difference betwe en the non-responders and responders.
We observed also statistically significant difference in the SUVm/s ratio prior
and after treatment in the responders patients. The longest diameter on CE-CT
of the lesions was determined and in the non-responders there was no
statistically significant difference pre and post three cycles of the PRRT. In the
group of the responders there was statistically significant difference between
the LD on CE-CT pre and post therapy (2.96 ±0.40 vs.1.58±0.43, p =0.00001).
Conclusion
In this retrospective study, our data suggest that mean SUVmax
is a useful prognostic biomarker to improve patient selection undergoing
PRRT.
S367
BA C D E F G
Monday
B-1071 15:21
Perfusion-MRI and 18-FDG-PET for monitoring the effects of regorafenib
on experimental colorectal carcinomas in rats with immunohistochemical
validation
R. Eschbach, W. Fendler, M. Hacker, L. Havla, M.J. Schneider, L. Späth,
K. Nikolaou, M.F. Reiser, C.C. Cyran;
Munich/DE (
[email protected])
Purpose: To investigate a multimodal, multiparametric perfusion MRI / 18 F-
FDG-PET imaging protocol for monitoring regorafenib therapy effects on
experimental colorectal adenocarcinomas in rats with immunohistochemical
validation.
Methods
and Materials: Human colorectal adenocarcinoma xenografts (HT-
29) were implanted subcutaneously in n=17 (n=10 therapy group; n=7 control
group) female athymic nude rats (Hsd:RH-Foxn1rnu). The animals were
imaged at baseline and after a one-week daily treatment with regorafenib
(10 mg/kg bodyweight) using a multimodal, multiparametric perfusion MRI /
18 F-FDG-PET imaging protocol. In perfusion MRI, quantitative parameters of
plasma flow (PF, mL/100 mL/min), plasma volume (PV, %) and extraction flow
(EF, mL/100 mL/min) were calculated. In 18 F-fluoro-deoxyglucose-(18 F-
FDG)-PET, tumor-to-background-ratio (TTB) was calculated. Perfusion MRI
parameters were correlated with TTB and immunohistochemical assessments
of tumor angiogenesis (CD-31) and cell proliferation (Ki-67).
Results
Regorafenib significantly (p < 0.01) suppressed PF (80.9 ±7.9 to
51.1±16.9 mL/100 mL/min), PV (12.1 ±3.8 to 7.7± 1.6 %) and EF (13.9± 3.2 to
8.2±2.2 mL/100 mL/min) as well as TTB (3.4 ±0.6 to 1.9 ±1.1) between baseline
and day 7. Immunohistochemistry revealed significantly (p < 0.03) lower CD-31
(8.5±3.2 vs. 14.9 ±5.3) and Ki-67 (500.6± 102.3 vs. 596.3± 55.5) in therapy
group than in control group. Perfusion MRI parameters PF, PV and EF
showed strong and significant (r=0.64-0.77;p < 0.01) correlations to the PET
parameter TTB and moderate, but significant correlations (r=0.49-
0.57;p < 0.05) to immunohistochemical Ki-67. PF and PV also correlated
moderately to the CD-31-stainings (r=0.49-0.53;p < 0.05).
Conclusion
A multimodal, multiparametric perfusion MRI / PET imaging
protocol allowed for monitoring regorafenib therapy effects on experimental
colorectal adenocarcinomas with significant correlations between perfusion
MRI parameters and 18 F-FDG-PET, as validated by immunohistochemistry.
S368
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.