Role of uterine manipulator during laparoscopic endometrial cancer treatment.

OA: gold CC-BY-NC-ND-4.0
⚙ AI-generated summary by qwen3.7-flash, 2026-09-01 ⓘ

This narrative review analyzes literature on uterine manipulators in laparoscopic endometrial cancer surgery, concluding that while generally safe, application should be tailored to tumor dimension and myometrial infiltration grade.

One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works

⚙ AI-generated deep summary by qwen3.7-flash, 2026-09-01 · read from full text ⓘ

This review evaluates the safety of using uterine manipulators during laparoscopic hysterectomy for endometrial cancer, specifically addressing concerns regarding lymphovascular space invasion and retrograde tumor spillage. The authors analyzed existing literature to determine if manipulation increases oncological risks or complications, finding that most studies refute a significant link between manipulator use and adverse outcomes like positive peritoneal cytology or reduced survival rates. While some technical difficulties and rare mechanical complications were noted, the evidence suggests that standard surgical precautions are generally sufficient to mitigate potential risks associated with device usage. Relevance to endometriosis: listed as one indication for GnRH antagonists, though the paper's main focus is uterine fibroids.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

Endometrial cancer (EC) is the most frequent gynecologic malignancy with 61,000 new cases diagnosed per year in the USA. Gynecologic Oncology Group (GOG) LAP2 randomized study demonstrated a superimposable 5-year overall survival between laparotomic and laparoscopic approaches in EC treatment. In this context the uterine manipulator (UM) represents a valuable tool in order to increase the ergonomics of surgical gesture during a laparoscopic total hysterectomy. Despite the proven safety of the minimally invasive approach in EC treatment, neither the indication whether to use or not, nor the recommendation concerning a specific type of UM are provided by international guidelines. This narrative review aims to collect all the main findings in the literature about UM use to investigate its safety in EC patients. Based on the analysis of the literature research, the main results were categorized into two manipulator-related problems: the iatrogenic LVSI, and the retrograde tumor spillage. LVSI is defined as the presence of tumor cells within an endothelium-lined space. An electronic search was performed using the following keywords: 'uterine manipulator', and 'endometrial cancer'. The electronic database search provided a total of 93 studies. Of whom, 12 case reports, 5 studies not in English language, and 65 works not fitting the review scope were excluded from the analysis. Eleven studies were considered eligible for the purpose of the study. The most recent studies have highlighted the safety of the uterine manipulator in the early-stage EC laparoscopic treatment. All types of manipulators are considered to be fairly safe but its application should be tailored according to tumor dimension and grade of myometrial infiltration.
Full text 14,366 characters · extracted from pmc-nxml · 3 sections · click to expand

Intro

Endometrial cancer (EC) is the most frequent gynecologic malignancy with 61,000 new cases diagnosed per year in the USA ( 1 ). Surgical staging procedures including total hysterectomy, bilateral salpingo-oophorectomy, and nodal assessment are the standard treatment in case of apparent uterine-confined disease both in young and elderly patients ( 2 - 7 ). Furthermore, recent data support the sentinel lymph node technique for nodal staging in both low and high-risk EC patients ( 8 - 10 ). After the Gynecologic Oncology Group (GOG) LAP2 randomized study demonstrated a superimposable 5-year overall survival between laparotomic and laparoscopic approach, with fewer postoperative adverse events and shorter hospital stays in the latter group, minimally invasive surgery has been widely accepted and globally adopted for EC treatment ( 11 - 14 ). Moreover, several authors stressed the importance of surgical mini-invasiveness, the preservation of fertility, and the quality of life on the psychological well-being of gynecological cancer patients ( 15 , 16 ). Minilaparocopic surgery and novel robotic surgical platforms also demonstrated improvements in the EC patient's quality of life compared to classic laparotomic surgery ( 17 - 25 ). In this context the Uterine manipulator (UM) represents a valuable tool in order to increase the ergonomics of surgical gesture during a laparoscopic total hysterectomy. UM increases both the exposure of the vaginal fornix during colpotomy, and, through a cranial and lateral probe pressure, the distance between the ureter and the uterine cervix avoiding ureteral iatrogenic damage ( 16 ). Despite the proven safety of minimally invasive approach in EC treatment, neither the indication whether to use or not, nor the recommendation concerning a specific type of UM are provided by international guidelines ( 2 , 26 ). Furthermore, due to studies showing a potential increased incidence of lymphovascular space invasion (LVSI) related to the use of UM, there was a progressive negative trend in its application in case of uterine malignancies ( 27 , 28 ). Thus, although most recent studies demonstrated the safety of the UM in EC patients, there are still some concerns about its routinary use ( 29 - 31 ). This review aims to collect all the main findings in the literature about UM use to investigate its safety in EC patients from an oncological point of view. The principal objectives of this article are to investigate the correlations between UM application and the incidence of both iatrogenic LVSI and retrograde Fallopian-tube tumor spillage with a particular focus to their impact on oncological outcomes.

Methods

An electronic search was performed in double-blind by the two authors CVA and RA of all related studies until March 2020. Research on Pubmed, Web of Science, and Scopus was carried out using the following keywords: ‘uterine manipulator’, ‘and’, ‘endometrial cancer’. Two authors reviewed all extracted abstracts independently. The agreement about potential relevance was reached by consensus of the researchers; After the first selection, the authors evaluated the full-text copies of selected papers and separately extracted relevant data regarding study characteristics and outcomes. All bibliographies were analyzed to find additional eligible studies. Systematic reviews, meta-analyses, clinical trials, and original articles were included in the present review. Studies considered not in line with the purpose of the study, case reports, articles not in English language were excluded. The electronic database search provided a total of 93 studies. Of whom, 12 case reports, 5 studies not in English language, and 65 works not fitting the review scope were excluded from the analysis. Eleven studies were considered eligible for the study. The study selection flow-chart was reported in Figure 1 . Flow-chart. Based on the analysis of the literature research, the main results were categorized into two manipulator-related problems: the iatrogenic LVSI, and the retrograde tumor spillage. Furthermore, the results concerning the type of manipulator used were analyzed. The studies selected with principal findings are reported in Table 1 . EC, endometrial cancer; UM, uterine manipulator; MM, micrometastasis; ITC, isolated cell tumor; LVSI, lymphovascular space invasion. LVSI is defined as the presence of tumor cells within an endothelium-lined space ( 32 ). LVSI has been considered as one of the main prognostic factors influencing the survival and recurrence rate of early-stage EC patients ( 33 ). Furthermore, adjuvant radiation therapy in early-stage cases is established related to LVSI presence ( 2 ). Although previous studies showed a correlation between UM and increased LVSI rate; Machida et al . ( 34 ) confuted this finding by reporting that the application of UM during laparoscopic hysterectomy for EC was not associated with a higher LVSI frequency. Kitahara et al . ( 27 ) was the first to introduce the concept of a ‘pseudo-LVSI invasion’ reporting that the apparent greater presence of LVSI in patients undergoing laparoscopic surgery was due to artifacts during the grossing pathological process rather than a real invasion. Dekker et al . ( 35 ) also described how to distinguish pseudoinvasion from ‘true’ LVSI positivity. The presence of tumor cells near large venous or arterial vessels and perivascular lymphocytes are typical of true infiltration of the lymphovascular spaces. Leaving aside the differences between focal and diffuse LVSI presence, several features have been described as LVSI mimics in the pathological analysis ( 36 , 37 ). The main LVSI mimic is the presence of neoplastic cells within the myometrial clefts and in large widened vessels due to the increased manipulator-related intrauterine pressure ( 38 ). This phenomenon is particularly present in gross crumbling tumors, as well as during manipulation with inflated balloon UM. Finally, Frimer et al . ( 39 ) investigated the presence of micrometastases (MM) and isolated tumor cells (ITC) with the use of UM during EC surgical treatment. Again, uterine manipulation did not appear to be related to a MM and ITC increase in the 175 patients analyzed, regardless of the type of UM used (Humi, Zumi, Hulka, and V-care devices). Some studies have claimed that uterine manipulation can cause retrograde transtubal tumor cells diffusion during laparoscopic hysterectomy resulting in positive peritoneal cytology ( 40 , 41 ). The increase in intrauterine pressure with the UM insertion could flake the endometrium and subsequently push the neoplastic cells into the peritoneal cavity through the tubes. Following these hypotheses, over the years the practice of coagulating the tubes before the insertion of the UM has been adopted. The same dilemmas have been posed for the endometriosis and some authors also claim a possible iatrogenic retrograde spillage of cancer cells during hysteroscopy for suspected EC ( 42 - 44 ). Regardless of the surgical precautions, almost all studies have refuted this hypothesis, and the practice of coagulating the tubes has not proved to be necessary or sufficient to avoid positive peritoneal cytology ( 44 - 48 ). Shinohara et al . ( 45 ) in a prospective study evaluating the retrograde dissemination of neoplastic cells during laparoscopic hysterectomy for early-stages EC, reported a risk reduction through the cauterization of fallopian tubes. The Japanese authors assessed the presence of tumor cells in the peritoneal washing fluid performed before the UM insertion and after that the hysterectomy had been completed. Although 13 patients had been enrolled in the study, only one patient showed tumor cells in the peritoneal cavity after UM insertion. Conflicting results have been obtained from extensive research of the literature carried out by Guralp et al . ( 46 ). The authors found an approximately 10% increase in cancer cells in the peritoneal fluid after laparoscopic hysterectomy with UM, but these factors did not change the prognosis of early-stage EC patients. Finally, Lee et al . ( 47 ) in a randomized study did not show an increase in peritoneal tumor cells nor an increase in positive LVSI in the 55 patients randomized to the uterine manipulator arm compared to patients treated without UM. Alternative techniques have also been described for uterine manipulation without uterine probes ( 49 ). Anyhow, international guidelines do not recommend coagulation of the tubes before the insertion of the intrauterine device, although peritoneal washing is instead recommended ( 2 , 26 ). Standardization of the exact type of UM to be used in EC cases is missing. The choice often depends on the cancer center or the surgeon’s personal experience. Due to these aspects, clinical trials analyzing the same types of uterine probes in different centers are still absent. However, empirically it would be thought that manipulators with an inflatable intrauterine probe such as the Rumi manipulator are less traumatic than manipulators with a metal spiral to be screwed into the cervix ( 50 , 51 ). Uccella et al . ( 30 ) compared the oncological outcomes of Rumi-Kho (CooperSurgical, Inc., Trumbull, CT), Minelli, Clermont-Ferrand (Karl Storz GmbH & Co., Tuttlingen, Germany), and Cohen (Sklar Surgical Instruments, West Chester, PA) manipulator without finding differences in the risk of recurrence, specific disease survival, overall survival and site of recurrence between the different UM type. For each patient, evaluation of peritoneal washing before and after UM insertion was performed to identify the cases in which the UM lead to a retrograde spillage of tumor cells. Finally, the same authors divided the manipulators into two groups concerning the presence or absence of an inflated balloon, but also in this case, no difference was found in the two groups. Despite these encouraging results, the UM use could increase the technical difficulties of the surgical procedure or lead to non-cancer-related operative complications ( 52 ). Uterine mobilization in the presence of android anatomical conformation of the pelvis of some women, or the case of very large uteri, could decrease with the positioning of the UM ( 53 ). Furthermore, the cranial push of the uterus after positioning the manipulator would bring the uterine fundus close to the trans-umbilical optics, limiting the vision of the operating field. Although rarely, several related UM positioning complications have been described in the literature. Uterine perforations, device ruptures inside the patient, and vaginal wall lacerations with hemorrhage have been described with the positioning of the RUMI type manipulator ( 54 ). While, intestinal perforation, uterine perforation, and pelvic pseudoaneurysm rupture have been described with the Hohl manipulator ( 55 , 56 ). Undoubtedly, UM use has advantages, but as reported by van den Haak et al . in an extensive review analyzing PubMed, Embase, Web of Science, COCHRANE, CINAHL, Academic Search Premier, Science Direct, and the MAUDE database, the scientific evidence demonstrating the effectiveness and advantages of UM is scarce ( 57 ). The same authors, despite the absence of randomized clinical trials, have reported that the Clermont Ferrand type is the manipulator associated with the least complications, easy to use, and that allows good exposure of the operating field. Furthermore as reported, the UM could be useful in iatrogenic or congenital vaginal stenoses ( 58 ). No clinical trial compared the time of a hysterectomy with or without the use of the UM. The mean operating times of a total hysterectomy with UM ranged from 83 to 141 minutes ( 57 ). However, Ng et al ., analysis 435 women, emphasized that the operating times and estimated blood losses (EBL) did not depend on the UM use but rather on the size of the uterus ( 59 ). This study showed that uteri smaller than 5 cm had a median operating time of 43 minutes with 50 mL EBL, compared to 136 minutes and 313 mL EBL for larger uteri. Finally, Macciò et al ., in cases of uteri even heavier than 800 g, showed how the manipulator can increase uterine lateralization, allowing better ureteral identification and greater safety during colpotomy time, due to the presence of the manipulator's vaginal cup ( 60 ). To date, the Role of Uterine Manipulator in Hysterectomy - Ro.Man.HY (RoManHy) multicentric prospective randomized Phase III trial (identification N. NCT02762214 ) is ongoing and could elucidate the role of the Clermont-Ferrand Uterine Manipulator in the early-stage EC.

Conclusions

The most recent studies have highlighted the safety of the uterine manipulator in the early-stage EC laparoscopic treatment. The LVSI positivity should be pathologically standardized and the ‘pseudo-LVSI invasion’ must be considered in all cases where the uterine manipulator is placed. It is crucial in this perspective to provide accurate clinical information to the pathologist, such as the positioning of the UM, to correctly interpret the LVSI status on definitive histological examination. Otherwise, Fanfani et al . ( 29 ) demonstrate that the application of UM does not represent a bias for the correct evaluation of myometrial infiltration, histotype, and grade of differentiation in the setting of the frozen section analysis. Tubal coagulation does not seem to decrease the presence of peritoneal neoplastic cells, however, it is a very simple and quick procedure and generally not related to any intraoperative complications. It has also to be considered that the vast majority of EC patients underwent a hysteroscopic assessment as a milestone of their preoperative work-up. It is now widely accepted that this procedure is not burdened by an increased risk of positive peritoneal cytology thus not requiring any specific countermeasures to avoid retrograde tubal flow. To date, all types of manipulators are considered to be fairly safe but its application should be tailored according to tumor dimension and grade of myometrial infiltration. We assume that for large lesions with suspected infiltration up to the serosal layer the positioning of UM could be avoided because of the higher risk of uterine perforation. Additional randomized clinical trials are needed to evaluate the safety of various types of uterine manipulator.

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

⚙ Ask this paper AI returns verbatim quotes from the full text · source: pmc-nxml ⓘ

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-10-04T09:26:46.659050+00:00
unpaywall
last seen: 2026-05-21T05:10:58.409756+00:00
License: CC-BY-NC-ND-4.0