A Bidirectional Fabric-Based Soft Robotic Glove for Hand Function Assistance in Patients with Chronic Stroke | Research Square window.SnipcartSettings = { analytics: { enabled: false } }; (function() { var accessVector = localStorage.getItem('access_vector') || ''; window.dataLayer = window.dataLayer || []; if (accessVector) { window.dataLayer.push({ user: { profile: { profileInfo: { snid: accessVector } } } }); } })(); (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R'); Browse Preprints In Review Journals COVID-19 Preprints AJE Video Bytes Research Tools Research Promotion AJE Professional Editing AJE Rubriq About Preprint Platform In Review Editorial Policies Our Team Advisory Board Help Center Sign In Submit a Preprint Cite Share Download PDF Research Article A Bidirectional Fabric-Based Soft Robotic Glove for Hand Function Assistance in Patients with Chronic Stroke Daniel Yuan-Lee Lim, Hwa-Sen Lai, Raye Chen-Hua Yeow This is a preprint; it has not been peer reviewed by a journal. https://doi.org/ 10.21203/rs.3.rs-2229531/v1 This work is licensed under a CC BY 4.0 License Status: Published Journal Publication published 21 Sep, 2023 Read the published version in Journal of NeuroEngineering and Rehabilitation → Version 1 posted 7 You are reading this latest preprint version Abstract Background Chronic stroke patients usually experience reduced hand functions, impeding their ability to perform activities of daily living (ADLs) independently. Additionally, improvements in hand functions by physical therapy beyond six months after the initial onset of stroke are much slower than in the earlier months. As such, chronic stroke patients could benefit from an assistive device to enhance their hand functions, allowing them to perform ADLs independently daily. In recent years, soft robotics has provided a novel approach to assistive devices for motor impaired individuals, offering more compliant and lightweight alternatives to traditional robotic devices. The scope of this study is to demonstrate the viability of a fabric-based soft robotic (SR) glove with bidirectional actuators in assisting chronic stroke study participants with hand impairments in performing ADLs. Methods Force and torque measurement tests were conducted to characterize the SR Glove, and hand functional tasks were given to eight chronic stroke patients to assess the efficacy of the SR Glove as an assistive device. The tasks involved object manipulation tasks that simulate ADLs, and the series of tasks was done by the participants once without assistance for baseline data, and once while using the SR Glove. A usability questionnaire was also given to each participant after the tasks were done to gain insight into how the SR Glove impacts their confidence and reliance on support while performing ADLs. Results The SR Glove improved the participants’ manipulation of objects in ADL tasks. Difference in mean scores between the unassisted and assisted conditions was significant across all participants. Additionally, the usability questionnaire showed the participants felt more confident and less reliant on support while using the SR Glove to perform ADLs than without the SR Glove. Conclusions The results from this study demonstrated that the SR Glove is a viable option to assist hand function in chronic stroke patients who suffer from hand motor impairments. Soft robotics Chronic stroke Activities of daily living Assistive device Fabric-based actuator Case Series Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 I. Background Stroke is the most common cerebrovascular disease ( 1 ) and while the majority of stroke patients survive, up to 30% of all stroke survivors experience limited motor function recovery ( 2 ). Consequently, stroke is also one of the main causes of adult disability ( 3 ), and many victims experience a reduction of hand motor function, restricting the victim’s ability to perform activities of daily living (ADLs) independently, negatively impacting their quality of life. Stroke patients with hand impairments require physical therapy, usually involving repetitive task practice rehabilitation ( 4 ), to improve hand function in terms of the range of motion and strength. However, around 65% of stroke patients are still unable to incorporate their affected hand into ADLs six months after the initial onset of stroke ( 5 ) and only 25% of patients return to a functional level similar to that of community-matched persons who have not suffered from a stroke ( 6 ). In many of these chronic stroke cases, the patients enroll in step-down care services, where they undergo regular physical therapy. However, the rate of recovery of upper extremity function beyond six months after stroke is a lot slower than during the first three to six months ( 7 ). Therefore, there is a need for assistive devices to aid chronic stroke patients in enhancing their hand functions to perform ADLs and regain independence in their daily lives. Robotics has been presented as a non-invasive method of improving hand motor function using wearable actuators such as robotic exoskeletons. These exoskeletons aid the users in moving their fingers and hands. While several robotic exoskeletons have been developed for the upper limb, many rely on linear actuators and rigid linkages ( 8 – 10 ) aligned precisely to the users’ joints to transfer forces safely and efficiently. The rigid mechanical design of these exoskeletons limits portability due to their size and weight. As a result, many of these systems are stationary, designed solely for use in clinical settings and to be operated by professionals to ensure the patient’s safety. On top of that, their rigid nature leads to a reduction in patient comfort when using the exoskeletons. These conditions are not ideal to be used regularly as assistive devices. Lightweight, user-friendly, and portable exoskeletons that could be used in both clinical and home settings as assistive devices would help create new possibilities that would be more suited for chronic stroke patients in day-to-day life. In recent years, several wearable hand exoskeletons have been developed using soft robotics. These compliant wearable exoskeletons incorporate fabrics ( 11 , 12 ), polymers ( 13 ) and soft elastomeric actuators ( 14 – 16 ) instead of traditional rigid linkages, which allow for a more comfortable experience for the patients, as well as eliminate the need for complicated mechanical setups and trained personnel to operate. These novel approaches to wearable robotics introduce the possibility for safe and user-friendly devices for daily assistance at home or therapy over prolonged periods ( 14 – 17 ). The objective of this study is to investigate the viability of a fully fabric-based soft robotic (SR) glove with bidirectional (i.e., finger flexion and finger extension) actuators in assisting chronic stroke study participants with hand mobility impairments in performing ADLs. To assess the effectiveness of the SR Glove as an assistive device, the study team adapted a series of hand functional tasks based on recognized and widely used hand assessments for stroke patients. The user-friendly design of the SR Glove module allowed participants to independently control the SR Glove using the Robotic Glove Control Box with minimal training. In addition to assessing the mechanical assistance by the glove, each participant did a usability questionnaire to gather information about how using the SR Glove affects their confidence in performing the ADL tasks as well as their reliance on support for performing ADLs with and without the SR Glove. Ii. Methods A. SR Glove Module The SR Glove module ( 11 ) used in this study comprises of two parts: the SR Glove and the Robotic Glove Control Box (Fig. 1a). The Robotic Glove Control Box controls the activation of the actuators embedded in the SR Glove which in turn dictates what movements the SR Glove will assist the patient with. The SR Glove consists of the fabric glove and four pneumatic actuators that are inserted in the dorsal side of the fabric glove, aligned with the four fingers (excluding the thumb). To address the lack of fine motor control and misalignment of most stroke survivor’s thumbs, participants wore a thumb splint made of thermoset plastic to assist in holding the thumb in opposition with the four fingers (Fig. 1b). This was necessary to allow the users to perform the tasks in the trial, such as grasping objects. The actuators (Fig. 1c) in the SR Glove are bidirectional actuators that are fabricated entirely out of fabric. Each bidirectional actuator is made of two separate pneumatic actuators, the flexion actuator, and the extension actuator, which are secured together with TPU fabric. At the base of both actuators, pneumatic tube adapters are inserted to serve as air inlets. The extension actuator resembles a traditional flat fabric pneumatic actuator. The flexion actuator, while similar to the extension actuator, is folded in a corrugated manner. The design of the corrugated fold allows the flexion actuator to achieve a bending motion, mimicking normal finger flexion when it is pressurised. Before pressurisation, both actuators are compliant and flexible. This compliance in their non-pressurised state is essential in ensuring that the range of motion of the participant’s fingers is not impeded. Compared to a previous iteration ( 11 ), the actuators presented in this paper are fabricated with a stiffer material (500GSM Double TPU Coated 420D Nylon). The Robotic Glove Control Box (Fig. 2a) comprises a microcontroller, an electronic air pump, pressure sensors and solenoid valves. A pressure control loop (Fig. 2b) was implemented to drive the valves. Each valve is connected to an actuator in the SR Glove via pneumatic tubing. The control box also includes buttons to select the desired movement for the exercise and an LCD screen to visually assist the user in selecting the movements. As a movement is selected, the microcontroller activates the air compressor and opens the valves leading to the actuators that are meant to be activated, resulting in the desired movement of the SR Glove. The default available movements were Palmar Grasp, 2-point Pinch (index finger flexion), 3-point Tripod Pinch (index and middle finger flexion) and Extend (all four fingers extension) (Fig. 2c). B. Actuator Characterization and Force Measurements Flexion Actuators The flexion actuators were characterised and evaluated in terms of the blocked tip force and grip forces applied upon pressurisation. Blocked tip force measurements were done using a customised force measurement setup, which comprised a mounting platform for the flexion actuator and a compression load cell (Fig. 3a). The force measurement setup was similar to that of previous studies ( 16 , 18 , 19 ). When pressurized, the flexion actuator’s bending motion is constrained by the two adjustable straps, which minimises the non-linear effects caused by the bending of the actuator when pressurised. This in turn helps ensure that the compression load cell would read the maximum blocked tip force generated by the actuator regardless of the bend angle. The distal end of the actuator was in contact with the compression load cell. Force was measured at pressure intervals of 10kPa from 10kPa to 130kPa and repeated three times at every interval. The grip force applied by the flexion actuators was measured with a universal testing machine (Handy Tester JSV H10000) to obtain normal and frictional grip forces. The force measurement setup was similar to those reported in previous literature ( 16 , 18 , 20 ). Four actuators, corresponding to the four fingers, were pressurised to 130kPa to bend and grasp a cylinder that is 80mm in diameter in a vertical orientation for frictional grip force (Fig. 3b), and horizontal orientation for normal grip force (Fig. 4). The cylinder was then pulled upwards by the universal testing machine at a fixed velocity of 8mm/s to the point where the actuators release the cylinder. The tests were repeated three times and the results were averaged. Extension Actuators The extension actuator is characterised by the amount of extension torque it can produce. The torque output was obtained using a customised torque testing rig, and a load cell sensor (Fig. 5). Using the torque testing rig, force exerted by the extending motion of the actuators is detected by the load cell as the mounting platform pushes against the load cell and is converted to static torque based on the distance from the load cell to the axis of rotation. The static torque of the extension actuator was measured from 0° to 90° in 10° intervals while the actuator was pressurized at 130kPa. C. Study Design This study evaluated the efficacy of the SR Glove as an assistive device in enhancing hand function in chronic stroke patients with limited hand recovery in step-down care (IRB Approval: LH-19-014). The trials were conducted in a case series design, whereby each participant first completed the tasks in the unassisted condition and then repeated the tasks in the assisted condition, all in a single session. Unassisted hand function was first evaluated by assessing their performance in ADL tasks which can be split into three different categories. Firstly, grasping different sizes of blocks, bottles, and balls (Fig. 6a) (3 points per type of object, maximum of 9 points). Secondly, gripping and manipulating utensils (Fig. 6b) and pens (6 points maximum). Finally, pinching small cubes and coins (6 points maximum). The participants would then repeat the tasks in the assisted condition while wearing the SR Glove on their paretic hand (Fig. 6c). The participants were instructed to independently operate the SR Glove module by using their non-affected hand to press the buttons on the Robotic Glove Control Box in the assisted condition. Additionally, the participants could also use their non-affected hand to place the objects in the affected hand to stabilize the initial grip if they required it in both conditions. The trials were held at local rehabilitation centers. The participants were recruited among regular patients in the rehabilitation centers, under referral by their therapists. Every participant underwent a proper procedure of recruitment, eligibility screening, and consent taking prior to the trial and had to agree with the procedures of the trial and data collection for research purposes. Participants’ demographics and research-related data were collected after successful enrolment such as gender, age, date of birth, date of diagnosis, type of stroke, duration of the stroke, and affected side. After being successfully enrolled, the participants underwent pre-trial assessments to evaluate their grip strength by squeezing a hand dynamometer. After completing the hand functional tasks under both conditions, participants underwent a post-trial grip strength test. Lastly, a usability questionnaire was given to patients to evaluate their level of confidence and reliance on support in ADLs. D. Participants and Eligibility Criteria A total of eight chronic stroke patients participated in the study (Table 1 ). The enrolled patients were from two local rehabilitation centers (both centers are operated by Handicaps Welfare Association, Singapore). The inclusion criteria included patients suffering from chronic stroke, either ischemic or hemorrhagic; from the ages of 20 to 90 years regardless of gender and race; unilateral upper limb impairment; ability to comprehend and follow instructions; ability to maintain upright sitting for at least 30 mins. Table 1 Demographics of the Chronic Stroke Patients Recruited in the Study Age 70 ± 8.28 Gender Male = 5 Female = 3 Stroke Type Ischemic = 5 Haemorrhage = 3 Location Cortex = 2 (e.g., occipital lobe, ACA) Subcortex = 7 (e.g., thalamus, basal ganglia, pons) Affected Side Left = 5 Right = 3 Duration (years) 5.41 ± 6.95 Grip Strength 8.29 ± 10.72 *Based on the voluntary movement, grip strength, and duration of the stroke, participants were classified into high and low functional groups. We excluded patients with recurrent stroke, unstable medical conditions, severe depression or active psychiatric disorder, epilepsy or seizure, severe spasticity (Modified Ashworth Scale > 2), contracture and deformity, poor skin conditions, and cognitive impairment. In addition, pregnant women were excluded from this study. All the participants were able to make decisions by themselves and give their consent to this trial. E. Outcome Measures Hand Functional Tasks : The hand functional tasks adapted for this trial by the study team were based on recognized and widely used hand assessments for stroke patients, such as Fugl-Meyer Assessment-Upper Extremity (FMA-UE), Action Research Arm Test (ARAT), and Arm Motor Ability Test (AMAT). These hand functional tasks allowed for observation and assessment of the participant's abilities to perform ADLs with and without assistance from the SR Glove with a focus on finger extension and finger flexion. The assessments were measured on the affected hand. A higher score indicates a better performance or a higher functional level. Grip Strength : The maximum bare-hand grip strength of the participants was measured by using a standard Jamar Hydraulic Hand Dynamometer. Patients were asked to position the studied hand in 90 degrees of elbow flexion next to the body and squeeze the hand dynamometer three times before the trial and three times after the trial, and force measurements were averaged. Usability Questionnaire (Level of Confidence in Performing ADLs and Reliance on Support for ADLs) : After completing the trial, a questionnaire designed by the study team was given to the participants for their feedback on the experience using the SR Glove, their level of confidence and their reliance on support from caretakers in performing ADLs while being unassisted or assisted by the SR Glove. The questionnaire had the participants indicate their confidence in performing the tasks based on the group of objects (bottle, block, pen, etc. – 5 points per object, 35 points maximum), as well as their reliance on support while performing ADLs (1 for highest reliance, 5 for lowest reliance) with and without the assistance from the SR Glove. F. Data Collection and Statistical Analysis All trials were video recorded for rating post-test. The outcome measures and participant responses were recorded and paired (unassisted versus assisted and pre-trial versus post-trial). The responses were coded, entered, and analyzed by using Statistical Package for Social Sciences (SPSS) version 25. Descriptive results such as the mean and the standard deviation were calculated. Given the small sample size, a nonparametric statistic test, the Wilcoxon Signed Ranks test, was applied to compare the two conditions (unassisted versus assisted by SR Glove) to observe the differences in results among the patients. A significance level of ≤ 0.05 was used in the analyses. Iii. Results A. SR Glove Actuator Characterization Blocked Tip Force Measurement The force produced by the SR Glove Actuators increased with greater pressure. The actuators generated a maximum tip force of 22.2N at 130kPa (Fig. 7a), which is also the operating pressure of the actuators. Compared to the previous iteration of a fully fabric Soft Robotic Glove ( 11 ), these actuators are able to produce a greater maximum tip force at their operating pressure. Grip Force Measurements The grip force measurements (normal grip force and frictional grip force) showed that the SR Glove Actuators generated 60.01 ± 5.50N of normal grip force and 13.53 ± 1.93N of frictional grip force using a cylinder with a diameter of 80mm (Fig. 7b and 7c). The frictional grip force provided by the flexion actuators is sufficient to lift most objects of daily living, which typically do not weigh more than 1.5kg ( 21 ). Extension Torque Stroke patients with hand impairments typically have increased muscle tone in the finger flexors on their affected hand, leading to an unintentionally clenched hand. It is therefore essential that the SR Glove Actuator can produce enough extension torque to extend the users’ fingers to grasp objects successfully. A single extension actuator was found to be able to generate a maximum of 0.70Nm at 90° (Fig. 7d). Assuming all extension actuators generate the same amount of torque, the maximum total extension torque achieved by four actuators would be 2.8Nm at 90°. Based on a previous study, the total finger flexion torque of stroke patients with spastic finger flexors is estimated to be within 0.5–4 Nm ( 22 ). Therefore, the results suggest that the SR Glove can counteract a total flexion torque of up to 2.8Nm and assist in finger extension, depending on the severity of the participant’s spasticity. B. Trial with Chronic Stroke Patients Hand Function – Finger Extension and Finger Flexion Individual participant scores in the hand function tasks, separated into tasks focused on hand opening and hand closing, are illustrated in Fig. 8a and 8b to provide insight into the score differences for each participant between unassisted and assisted conditions. Mean results across all test participants for the hand opening and closing tasks in unassisted and assisted conditions are also presented in Fig. 9a and Table 2 . Table 2 Outcome Measures Subject Affected Side Hand Opening Hand Closing Difference (Assisted – Unassisted) Grip Strength (kg) Unassisted Assisted Unassisted Assisted Open Closed Pre Post Difference G001 L 14 16 14 16 2 2 25.50 24.92 -0.58 G002 R 21 21 21 21 0 0 25.00 24.90 -0.1 G003 L 0 21 7 17 21 10 2 3.27 1.27 G004 R 9 19 13 16 10 3 4.50 7.76 3.26 G005 R 7 19 14 16 12 2 2.33 1.93 -0.37 G006 L 3 18 5 15 15 10 0 0 0 G007 L 11 17 12 14 6 2 7.00 3.00 -4 G008 L 0 16 12 17 16 5 0 0 0 Mean ± SD (total) 8.13 ± 7.26 18.38 ± 2.00 12.25 ± 4.83 16.50 ± 2.07 10.25 ± 7.23 4.25 ± 3.81 8.29 ± 10.72 8.22 ± 10.58 -0.07 ± 2.02 Hand Functional Tasks: the maximum score is 21. Abbreviation: L: Left; R: Right; SD: Standard Deviation; The mean score difference between the unassisted and assisted conditions improved significantly across the group of eight participants. The mean score for Open Hand Tasks in the assisted condition (18.38 ± 2.00) showed an improvement of more than double of the unassisted condition (8.13 ± 7.26). This shows a significant improvement in finger extension function when participants used the SR Glove (Wilcoxon signed-rank test, Z = -2.366, p = 0.018). The mean score difference for the Closed Hand Tasks was similar. The mean unassisted score was found to be 12.25 ± 4.83 while the mean score for the assisted condition was 16.50 ± 2.07. This was also a significant increase in finger flexion function when participants used the SR Glove (Wilcoxon signed-rank test, Z = -2.388, p = 0.017). Participant Grip Strength The mean grip strength did not exhibit a statistically significant change post-trial ( p = 0.753, Table 3 and Fig. 9b). As the trials were conducted in a single session, an increase in grip strength, which would require an extended training timeline, was not expected. Furthermore, rather than strength gaining, this trial focused on hand functional movement. Table 3 Wilcoxon Signed Ranks Test Statistics for the Outcome Measures. Hand Opening: Unassisted vs Assisted Hand Closing: Unassisted vs Assisted Grip Strength: Pre vs Post Z -2.366 -2.388 − .314 Asymp. Sig. (2-tailed) 0.018* 0.017* 0.753 *Statistically significant, < 0.05. Usability Questionnaire The questionnaire done by the participants after completing the trial reflected their level of confidence and reliance on support for ADLs with and without the SR Glove (Fig. 9c and 9d and Table 4 ). Table 4 Usability Questionnaire Subject Affected Side Level of Confidence Reliance on Support Unassisted Assisted Difference Unassisted Assisted Difference G001 L 20 21 1 4 3 -1 G002 R 30 30 0 4 4 0 G003 L 7 20 13 1 3 2 G004 R 18 20 2 2 4 2 G005 R 28 28 0 3 3 0 G006 L 7 22 15 1 3 2 G007 L 31 32 1 4 3 -1 G008 L 14 28 14 2 4 2 Mean ± SD (total) 19.38 ± 9.71 25.13 ± 4.88 5.75 ± 6.88 2.63 ± 1.30 3.38 ± 0.52 0.75 ± 1.39 Usability Questionnaire: the maximum score of Level of Confidence is 35; the maximum score of Reliance on Support is 5. Abbreviation: L: Left; R: Right; SD: Standard Deviation; Out of a maximum of 30 points, the participants rated their confidence in performing the ADL tasks in the unassisted condition with a mean score of 19.38, and a mean score of 25.13 while using the SR Glove. This increase in confidence was significant (Wilcoxon signed-rank test, Z = -2.207, p = 0.027) (Table 5 ). Table 5 Wilcoxon Signed Ranks Test Statistics for the Questionnaire. Level of Confidence: Unassisted vs Assisted Reliance on Support: Unassisted vs Assisted Z -2.207 -1.622 Asymp. Sig. (2-tailed) 0.027* 0.105 *Statistically significant, < 0.05. Figures for “A Bidirectional Fabric-Based Soft Robotic Glove for Hand Function Assistance in Patients with Chronic Stroke” Additionally, participants felt they required less support by caretakers while using the SR Glove, with a mean score of 3.38 in the assisted condition and a mean score of 2.63 in the unassisted condition (Fig. 9d), though this was not statistically significant. Iv. Discussion The viability of a fabric-based soft robotic glove in assisting chronic stroke participants with hand impairments to perform ADLs was investigated in this study. The study team adapted a series of hand functional tasks (FMA-UE, ARAT and AMAT) to assess the hand manipulation of the participants in unassisted and assisted (using SR Glove) conditions, with a focus on finger extension and flexion, as well as object manipulation. Compared to the unassisted condition, the improved scores and reduction in variability when they were assisted by the SR Glove suggest that the glove is capable of enhancing the hand function of participants with impaired unaided performance to a more functional level. These results are consistent with previous studies ( 23 – 25 ). Moreover, many studies on robotics in rehabilitation present improvements in motor functions and cortical excitability in stroke patients, most likely relating to neuroplasticity ( 26 – 28 ). In this study, we found that individuals with low unassisted scores (G003 and G006) experienced great benefits from using the SR Glove, with great improvements to their hand functional scores. In contrast, individuals with higher unassisted scores (G001, G002) did not experience notable benefits from the SR Glove. We believe this may be due to the ceiling effect when assessing patients with higher hand functions who generally present better motor control and less overall spasticity. This outcome suggests the SR Glove might be more beneficial for patients who suffer from severe to moderate impairment and experience decreased hand strength, an inability to initiate movement, and have spastic hands ( 29 , 30 ). In addition, we also observed that the relatively large standard deviation from the unassisted condition was reduced in the assisted condition, suggesting the SR Glove provided consistent assistance across all participants. This result is similar to a study done by Cappello et al. that also observed a decrease in the variability of participants’ performance while wearing the soft robotic glove ( 31 ). As is consistent among chronic stroke patients with muscle spasticity, our participants presented unintentionally clenched fists on their affected sides. To address this, the SR Glove Actuators are bidirectional and can assist the user in extending as well as flexing their fingers. Extension torque tests show the SR Glove can generate a peak torque of 2.8Nm. The participants demonstrated a lower unassisted mean score in Open Hand Tasks as compared to Closed Hand Tasks (Table 2 ), which suggests a greater difficulty for the participants to perform reliable finger extension than flexion. Assistance with the SR Glove provided a significant improvement to their Open Hand Tasks scores. G003 was unable to perform any Open Hand tasks in the unassisted condition as they could not perform finger extension without assistance. With the assistance of the SR Glove, G003 could easily extend their fingers to then grasp onto objects or release them. Reducing spasticity with robot-assisted training is also supported by a study conducted by Gandolfi et al., which suggests that it is as effective as conventional methods for spasticity reduction when combined with Botulinum toxin in chronic stroke patients with upper limb spasticity ( 32 ). Besides the hand functional outcomes, the usability questionnaire done by the participants post-trial indicated that the participants have a higher level of confidence in performing ADLs while being assisted with the SR Glove than without. This may suggest that the participants viewed the SR Glove as an effective assistive device. Additionally, there were no responses with a decrease in confidence while using the SR Glove. Results from the questionnaire also indicated the participants felt they had a lower reliance on support from caretakers when using the SR Glove. This study assessed the participants’ hand functions as well as their experience using the SR Glove Module. The participants operated the SR Glove themselves during the trial, using their non-affected hand to control the buttons on the Control Box. The intuitive design of the SR Glove module allowed them to familiarize themselves with operating it and perform the ADL tasks independently and successfully in a single session. This could have been a factor as to why the participants felt they could rely less on support from caretakers while performing ADLs with the SR Glove. Similarly, Li et al. conducted a mixed methods survey on the experiences of using rehabilitative robots and reported that stroke patients enjoyed using rehabilitative robots in therapy sessions. This was due to the rehabilitative robots providing greater variety in therapy choices, increasing the amount or intensity of treatment, and making the therapy accessible and convenient ( 33 ). As a result, patients have a greater motivation to practice and this increases their level of confidence in performing ADL tasks, especially when used at home ( 34 ). Given these advantages of rehabilitative robots, the whole system of the SR Glove is designed to be less bulky. The Control Box is made to be compact (16.4cm x 10.5cm x 14.9cm) (Fig. 1b) and lightweight, which makes it easy for transportation as well as ideal for home use. Given that users can independently operate the SR Glove as demonstrated by the participants of this study, it is potentially feasible for the SR Glove to be used as an assistive device at home. Studies have also suggested that a contributing factor to the plateau seen in poststroke recovery after 6 months is a neuromuscular adaptation to a standardized outpatient regimen of exercise ( 35 ). To address this, introducing novel rehabilitation protocols and mass practice has shown that considerable motor improvement is still possible in the chronic stage. Using the SR Glove in therapy sessions could potentially be the novel rehabilitation protocol that chronic stroke patients in rehabilitation centers use to experience hand motor improvements in their chronic stage. In addition, the SR Glove can be adapted to suit clinical environments. For example, the SR Glove can be used as a continuous passive motion device, simply extending and flexing the affected fingers to reduce spasticity in affected fingers. Alternative methods of control, such as electromyography (EMG), electroencephalography (EEG), and inertial measurement units (IMUs), could also be explored in the future to further enhance the operation of the SR Glove by the users. Therefore, future studies will aim to investigate the efficacy of the SR Glove in rehabilitative treatments. A key limitation of this study was the small sample size. We recognized that variances in characteristics, such as stroke type and time elapsed since onset of stroke, might impact the consistency of the overall results from the study. As we conducted this study amid the COVID-19 pandemic, we had to follow strict restrictions on physical contact, greatly limiting the number of participants we could recruit. Nevertheless, we managed to ascertain the importance for home-based assistance in chronic stroke patients with hand motor impairments. Future research will also need to investigate the durability and long-term usability of the glove while performing intensive testing sessions. Adjustments to the design of the SR Glove could improve the overall performance and user comfort while using the glove, such as adding silicone anti-slip material to the fingertips to aid gripping and incorporating a more suitable, thinner material on the palmar side of the glove to improve the precision of pinching and grasping objects. In addition, functional neuroimaging will provide a better understanding of the effect of robotic rehabilitation ( 26 – 28 ) and could be considered for future studies. Finally, adding sensors in the SR Glove will be essential in providing biofeedback to both patients and therapists; this will improve the training effect and efficacy ( 36 , 37 ). V. Conclusion This study provided insight into the efficacy of a fully fabric-based bidirectional soft robotic glove in improving basic hand functions in chronic stroke patients. Assessing the participants based on widely used hand assessments for stroke patients, assistance with the SR Glove showed significant improvements in finger flexion and extension when performing ADLs. Additionally, a usability questionnaire given to the participants showed that the participants had significantly greater confidence in performing the ADL tasks while using the SR Glove than without. These results, coupled with the SR Glove’s portability and intuitive operation, show that the SR Glove can be used both in rehabilitation center settings as well as in home environments as an assistive device to enhance hand function in chronic stroke patients with hand paresis. Abbreviations ADL: Activities of daily living; SR: Soft robotics; FMA-UE: Fugl-Meyer Assessment-Upper Extremity; ARAT: Action Research Arm Test; AMAT: Arm Motor Ability Test. Declarations Acknowledgement The authors would like to express their appreciation of the study participants for their willingness to take part in the study and for their feedback. We also acknowledge the occupational and physiotherapists at Handicaps Welfare Association for their hospitality and for their aid in the recruitment of participants. Availability of data and materials Data and materials can be made available upon request to the authors. Author’s contributions HSL designed the trial that was done with the participants. DYLL built the soft robotic glove and the control box and performed the experiments on the soft robotic glove. HSL and DYLL performed the experiments with the participants, analyzed and interpreted the data and wrote the manuscript. RCHY provided guidance over the entire study. All authors reviewed the manuscript and provided feedback on the manuscript. All authors read and approved the final manuscript. Ethics Approval and Consent to Participate This work was funded by the Tote Board Enabling Lives Initiative (TB-ELI) Grant. Ethics approval was obtained from the Institutional Review Board (IRB Approval: LH-19-014), National University of Singapore. All patients signed a consent form as part of the agreement. They were recruited under the Human ethics committee's approval, the Institutional Review Board (IRB), National University of Singapore. Consent for publication Written informed consent for publication was obtained from the participants involved in the study Competing interests The authors declare that they have no competing interests. References Brain's Diseases of the Nervous System. Donaghy M, editor: Oxford University Press; 2009 01 Jul 2011. Langhorne P, Coupar F, Pollock A. Motor recovery after stroke: a systematic review. Lancet Neurol. 2009;8(8):741–54. Tsao CW, Aday AW, Almarzooq ZI, Alonso A, Beaton AZ, Bittencourt MS, et al. Heart Disease and Stroke Statistics-2022 Update: A Report From the American Heart Association. Circulation. 2022;145(8):e153–639. Michaelsen SM, Dannenbaum R, Levin MF. Task-specific training with trunk restraint on arm recovery in stroke: randomized control trial. Stroke. 2006;37(1):186–92. Kwakkel G, Kollen BJ, van der Grond J, Prevo AJ. Probability of regaining dexterity in the flaccid upper limb: impact of severity of paresis and time since onset in acute stroke. Stroke. 2003;34(9):2181–6. Lai SM, Studenski S, Duncan PW, Perera S. Persisting consequences of stroke measured by the Stroke Impact Scale. Stroke. 2002;33(7):1840–4. van Kuijk AA, Pasman JW, Hendricks HT, Zwarts MJ, Geurts AC. Predicting hand motor recovery in severe stroke: the role of motor evoked potentials in relation to early clinical assessment. Neurorehabil Neural Repair. 2009;23(1):45–51. Worsnopp TT, Peshkin MA, Colgate JE, Kamper DG, editors. An Actuated Finger Exoskeleton for Hand Rehabilitation Following Stroke. 2007 IEEE 10th International Conference on Rehabilitation Robotics; 2007 13–15 June 2007. Ates S, Haarman CJW, Stienen AHA. SCRIPT passive orthosis: design of interactive hand and wrist exoskeleton for rehabilitation at home after stroke. Auton Robots. 2017;41(3):711–23. Polotto A, Modulo F, Flumian F, Xiao ZG, Boscariol P, Menon C, editors. Index finger rehabilitation/assistive device. 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob); 2012 24–27 June 2012. Yap HK, Khin PM, Koh TH, Sun Y, Liang X, Lim JH, et al. A Fully Fabric-Based Bidirectional Soft Robotic Glove for Assistance and Rehabilitation of Hand Impaired Patients. IEEE Rob Autom Lett. 2017;2(3):1383–90. Cappello L, Galloway KC, Sanan S, Wagner DA, Granberry R, Engelhardt S, et al. Exploiting Textile Mechanical Anisotropy for Fabric-Based Pneumatic Actuators. Soft Robot. 2018;5(5):662–74. Kang BB, Choi H, Lee H, Cho KJ. Exo-Glove Poly II. A Polymer-Based Soft Wearable Robot for the Hand with a Tendon-Driven Actuation System. Soft Robot. 2019;6(2):214–27. Polygerinos P, Galloway KC, Sanan S, Herman M, Walsh CJ, editors. EMG controlled soft robotic glove for assistance during activities of daily living. 2015 IEEE International Conference on Rehabilitation Robotics (ICORR); 2015 11–14 Aug. 2015. Yap HK, Lim JH, Nasrallah F, Cho Hong Goh J, Yeow CH. Characterisation and evaluation of soft elastomeric actuators for hand assistive and rehabilitation applications. J Med Eng Technol. 2016;40(4):199–209. Polygerinos P, Wang Z, Galloway KC, Wood RJ, Walsh CJ. Soft robotic glove for combined assistance and at-home rehabilitation. Robot Auton Syst. 2015;73:135–43. Yap HK, Mao A, Goh JCH, Yeow CH. Design of a wearable FMG sensing system for user intent detection during hand rehabilitation with a soft robotic glove. 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob); 2016 26–29 June 2016. Polygerinos P, Wang Z, Overvelde JTB, Galloway KC, Wood RJ, Bertoldi K, et al. Modeling of Soft Fiber-Reinforced Bending Actuators. IEEE Trans Robot. 2015;31(3):778–89. Yap HK, Sebastian F, Wiedeman C, Yeow CH. Design and characterization of low-cost fabric-based flat pneumatic actuators for soft assistive glove application. 2017 International Conference on Rehabilitation Robotics (ICORR); 2017 17–20 July 2017. Ang BWK, Yeow CH. Print-it-Yourself (PIY) glove: A fully 3D printed soft robotic hand rehabilitative and assistive exoskeleton for stroke patients. 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS); 2017 24–28 Sept. 2017. Matheus K, Dollar AM, editors. Benchmarking grasping and manipulation: Properties of the Objects of Daily Living. 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems; 2010 18–22 Oct. 2010. Kamper DG, Rymer WZ. Quantitative features of the stretch response of extrinsic finger muscles in hemiparetic stroke. Muscle Nerve. 2000;23(6):954–61. Vanoglio F, Bernocchi P, Mulè C, Garofali F, Mora C, Taveggia G, et al. Feasibility and efficacy of a robotic device for hand rehabilitation in hemiplegic stroke patients: a randomized pilot controlled study. Clin Rehabil. 2017;31(3):351–60. Susanto EA, Tong RK, Ockenfeld C, Ho NS. Efficacy of robot-assisted fingers training in chronic stroke survivors: a pilot randomized-controlled trial. J Neuroeng Rehabil. 2015;12:42. Bustamante Valles K, Montes S, Madrigal MdJ, Burciaga A, Martínez ME, Johnson MJ. Technology-assisted stroke rehabilitation in Mexico: a pilot randomized trial comparing traditional therapy to circuit training in a Robot/technology-assisted therapy gym. J Neuroeng Rehabil. 2016;13(1):83. Singh N, Saini M, Kumar N, Srivastava MVP, Mehndiratta A. Evidence of neuroplasticity with robotic hand exoskeleton for post-stroke rehabilitation: a randomized controlled trial. J Neuroeng Rehabil. 2021;18(1):76. Nasrallah FA, Mohamed AZ, Yap HK, Lai HS, Yeow CH, Lim JH. Effect of proprioceptive stimulation using a soft robotic glove on motor activation and brain connectivity in stroke survivors. J Neural Eng. 2021. Mehrholz J, Pollock A, Pohl M, Kugler J, Elsner B. Systematic review with network meta-analysis of randomized controlled trials of robotic-assisted arm training for improving activities of daily living and upper limb function after stroke. J Neuroeng Rehabil. 2020;17(1):83. Hijikata N, Kawakami M, Ishii R, Tsuzuki K, Nakamura T, Okuyama K, et al. Item Difficulty of Fugl-Meyer Assessment for Upper Extremity in Persons With Chronic Stroke With Moderate-to-Severe Upper Limb Impairment. Frontiers in Neurology. 2020;11. Sullivan KJ, Tilson JK, Cen SY, Rose DK, Hershberg J, Correa A, et al. Fugl-Meyer Assess Sensorimotor Function After Stroke Stroke. 2011;42(2):427–32. Cappello L, Meyer JT, Galloway KC, Peisner JD, Granberry R, Wagner DA, et al. Assisting hand function after spinal cord injury with a fabric-based soft robotic glove. J Neuroeng Rehabil. 2018;15(1):59. Gandolfi M, Valè N, Dimitrova EK, Mazzoleni S, Battini E, Filippetti M, et al. Effectiveness of Robot-Assisted Upper Limb Training on Spasticity, Function and Muscle Activity in Chronic Stroke Patients Treated With Botulinum Toxin: A Randomized Single-Blinded Controlled Trial. Frontiers in Neurology. 2019;10. Li L, Tyson S, Weightman A. Professionals' Views and Experiences of Using Rehabilitation Robotics With Stroke Survivors: A Mixed Methods Survey. Front Med Technol. 2021;3:780090. Akbari A, Haghverd F, Behbahani S. Robotic Home-Based Rehabilitation Systems Design: From a Literature Review to a Conceptual Framework for Community-Based Remote Therapy During COVID-19 Pandemic. Frontiers in Robotics and AI. 2021;8. Page SJ, Gater DR, Bach YRP. Reconsidering the motor recovery plateau in stroke rehabilitation. Arch Phys Med Rehabil. 2004;85(8):1377–81. Maceira-Elvira P, Popa T, Schmid A-C, Hummel FC. Wearable technology in stroke rehabilitation: towards improved diagnosis and treatment of upper-limb motor impairment. J Neuroeng Rehabil. 2019;16(1):142. Shi XQ, Heung HL, Tang ZQ, Tong KY, Li Z. Verification of Finger Joint Stiffness Estimation Method With Soft Robotic Actuator. Frontiers in Bioengineering and Biotechnology. 2020;8. Additional Declarations No competing interests reported. Cite Share Download PDF Status: Published Journal Publication published 21 Sep, 2023 Read the published version in Journal of NeuroEngineering and Rehabilitation → Version 1 posted Editorial decision: Major revision 12 Jan, 2023 Reviews received at journal 01 Dec, 2022 Reviewers agreed at journal 28 Nov, 2022 Reviewers invited by journal 28 Nov, 2022 Editor assigned by journal 04 Nov, 2022 Submission checks completed at journal 04 Nov, 2022 First submitted to journal 02 Nov, 2022 You are reading this latest preprint version Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal. As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing. Also discoverable on Platform About Our Team In Review Editorial Policies Advisory Board Help Center Resources Author Services Accessibility API Access RSS feed Manage Cookie Preferences © Research Square 2026 | ISSN 2693-5015 (online) Privacy Policy Terms of Service Do Not Sell My Personal Information {"props":{"pageProps":{"initialData":{"identity":"rs-2229531","acceptedTermsAndConditions":true,"allowDirectSubmit":false,"archivedVersions":[],"articleType":"Research Article","associatedPublications":[],"authors":[{"id":149440227,"identity":"579d4769-fcc1-4e0b-b018-117b1a5c9635","order_by":0,"name":"Daniel Yuan-Lee Lim","email":"data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAZAAAAAyAQMAAABI0h/eAAAABlBMVEX///8AAABVwtN+AAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAuklEQVRIiWNgGAWjYDCC4wyMBz5AmAZEajnMwHBwBslaDvOQpIXvMI/BYdsdh+0Z2Ju3STD8qSWsRRKkJffM4cQGnmNlEoxtxwlrMQBraTucwCCRYybB2HCMSC2WbUCHyb8xAzqMWC2MbYcZGyR4gFrYaghrkTzMVnCwty09sY0nrdgise0AYS18x5s3PvjZZm3Pz354440Pf+oIa2Fg4IBEBxuISABFE2HA/gCZR5Qto2AUjIJRMMIAAP6aOgG09YE3AAAAAElFTkSuQmCC","orcid":"","institution":"National University of Singapore","correspondingAuthor":true,"submittingAuthor":false,"prefix":"","firstName":"Daniel","middleName":"Yuan-Lee","lastName":"Lim","suffix":""},{"id":149440230,"identity":"67f66eac-5591-4044-be31-0eb6d8ac83e5","order_by":1,"name":"Hwa-Sen Lai","email":"","orcid":"","institution":"National University of Singapore","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Hwa-Sen","middleName":"","lastName":"Lai","suffix":""},{"id":149440231,"identity":"b89dbe2b-407b-4e0e-83cd-67b405728c51","order_by":2,"name":"Raye Chen-Hua Yeow","email":"","orcid":"","institution":"National University of Singapore","correspondingAuthor":false,"submittingAuthor":false,"prefix":"","firstName":"Raye","middleName":"Chen-Hua","lastName":"Yeow","suffix":""}],"badges":[],"createdAt":"2022-11-02 09:44:44","currentVersionCode":1,"declarations":"","doi":"10.21203/rs.3.rs-2229531/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-2229531/v1","draftVersion":[],"editorialEvents":[{"content":"https://doi.org/10.1186/s12984-023-01250-4","type":"published","date":"2023-09-21T15:00:36+00:00"}],"editorialNote":"","failedWorkflow":false,"files":[{"id":28875803,"identity":"61dfc407-83cd-439e-b8d7-2947362904f7","added_by":"auto","created_at":"2022-11-09 21:17:11","extension":"png","order_by":1,"title":"Figure 1","display":"","copyAsset":false,"role":"figure","size":249295,"visible":true,"origin":"","legend":"\u003cp\u003eSR \u0026nbsp;\u0026nbsp;Glove module: (a) The SR Glove Module, consisting of the SR Glove and the Robotic \u0026nbsp;\u0026nbsp;Glove Control Box. (b) The SR Glove worn on a left hand, showing the \u0026nbsp;\u0026nbsp;thermoset thumb splint and pneumatic tubing from the actuators inserted into \u0026nbsp;\u0026nbsp;the dorsal side of the glove. (c) Fabric bidirectional actuators inserted in \u0026nbsp;\u0026nbsp;the dorsal side of the fabric glove and aligned with the four fingers. Each \u0026nbsp;\u0026nbsp;actuator has two modes of movement (flexion and extension) and is the basis \u0026nbsp;\u0026nbsp;of how the SR Glove assists the users in finger flexion and extension \u0026nbsp;\u0026nbsp;respectively.\u003c/p\u003e","description":"","filename":"F1.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/8beba4ed3dfb2b5b1fe0055e.png"},{"id":28876582,"identity":"59ac29cf-a6a6-4a86-a26f-36d102eae603","added_by":"auto","created_at":"2022-11-09 21:25:11","extension":"png","order_by":2,"title":"Figure 2","display":"","copyAsset":false,"role":"figure","size":257749,"visible":true,"origin":"","legend":"\u003cp\u003eSR \u0026nbsp;\u0026nbsp;Glove module: (a) The Robotic Glove Control Box and its internals. A pressure \u0026nbsp;\u0026nbsp;control loop was implemented to drive the valves upon selection of the \u0026nbsp;\u0026nbsp;desired movement with the tactile buttons. (b) Control block diagram \u0026nbsp;\u0026nbsp;depicting the pressure control loop implemented in the Robotic Glove Control \u0026nbsp;\u0026nbsp;Box. (c) Control and coordination of the valves within the Robotic Glove \u0026nbsp;\u0026nbsp;Control Box help the SR Glove assist the user in four finger extension, \u0026nbsp;\u0026nbsp;palmar grasp, two-finger pinch, three-finger tripod pinch\u003c/p\u003e","description":"","filename":"F2.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/4937b8b581fe9789724f8acd.png"},{"id":28875804,"identity":"9bda3160-eaa5-4d79-a344-d3f7590aa0b9","added_by":"auto","created_at":"2022-11-09 21:17:11","extension":"png","order_by":3,"title":"Figure 3","display":"","copyAsset":false,"role":"figure","size":53367,"visible":true,"origin":"","legend":"\u003cp\u003e(a) \u0026nbsp;\u0026nbsp;Test setup for Blocked Tip Force measurements. The bidirectional actuator is \u0026nbsp;\u0026nbsp;held in place by a constraining roof and constraining straps to minimise \u0026nbsp;\u0026nbsp;non-linear effects caused by the bending of the flexion actuator when pressurised \u0026nbsp;\u0026nbsp;and force produced by the actuator is measured by the Load Cell. (b) Test setup for Frictional Grip Force \u0026nbsp;\u0026nbsp;measurements. The flexion actuators are pressurized to 130kPa and grip onto \u0026nbsp;\u0026nbsp;the cylinder mounted on the handy tester universal testing machine in a \u0026nbsp;\u0026nbsp;vertical orientation. The cylinder is pulled upwards at a fixed velocity of \u0026nbsp;\u0026nbsp;8mm/s to the point the actuators released the cylinder.\u003c/p\u003e","description":"","filename":"F3.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/d9d15814b1903af41209c636.png"},{"id":28874735,"identity":"d89ff2b4-ebf1-4638-a915-873b9f553b44","added_by":"auto","created_at":"2022-11-09 21:09:11","extension":"png","order_by":4,"title":"Figure 4","display":"","copyAsset":false,"role":"figure","size":43520,"visible":true,"origin":"","legend":"\u003cp\u003eTwo \u0026nbsp;\u0026nbsp;different angles of the test setup for Normal Grip Force measurements, (a): \u0026nbsp;\u0026nbsp;front view, (b): side view. The flexion actuators are pressurized to 130kPa \u0026nbsp;\u0026nbsp;and grip onto the cylinder mounted on the handy tester universal testing \u0026nbsp;\u0026nbsp;machine in a horizontal orientation. The cylinder is pulled upwards at a \u0026nbsp;\u0026nbsp;fixed velocity of 8mm/s to the point the actuators released the cylinder.\u003c/p\u003e","description":"","filename":"F4.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/3f673bac43f3bdaa51247b2e.png"},{"id":28874741,"identity":"9ca1f496-4bcc-49a9-a57c-8859e8c54e94","added_by":"auto","created_at":"2022-11-09 21:09:11","extension":"png","order_by":5,"title":"Figure 5","display":"","copyAsset":false,"role":"figure","size":470767,"visible":true,"origin":"","legend":"\u003cp\u003eTest \u0026nbsp;\u0026nbsp;setup for Extension Torque measurements. The extension actuator is \u0026nbsp;\u0026nbsp;pressurized at 130kPa, and static torque is measured at each flexion angle. Static \u0026nbsp;\u0026nbsp;torque is calculated as the product of the force measured by the load cell \u0026nbsp;\u0026nbsp;and the moment arm.\u003c/p\u003e","description":"","filename":"F5.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/88f14cae4067b3912a38e01a.png"},{"id":28874737,"identity":"f19f8da7-f5f6-4bd9-bd69-e0771001213f","added_by":"auto","created_at":"2022-11-09 21:09:11","extension":"png","order_by":6,"title":"Figure 6","display":"","copyAsset":false,"role":"figure","size":630369,"visible":true,"origin":"","legend":"\u003cp\u003e(a) \u0026nbsp;\u0026nbsp;Trial setup. (b) Gripping and manipulating utensils with the bare affected \u0026nbsp;\u0026nbsp;hand. (c) Performing functional tasks with the SR Glove on their paretic hand \u0026nbsp;\u0026nbsp;and operating the Robotic Glove Control Box with their contralateral hand.\u003c/p\u003e","description":"","filename":"F6.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/11fe689600cea182def969a9.png"},{"id":28874740,"identity":"aa02343c-4f57-4c1d-ace7-8a31790e0e61","added_by":"auto","created_at":"2022-11-09 21:09:11","extension":"png","order_by":7,"title":"Figure 7","display":"","copyAsset":false,"role":"figure","size":63168,"visible":true,"origin":"","legend":"\u003cp\u003e(a) \u0026nbsp;\u0026nbsp;Blocked tip force generated by the flexion actuators. (b) Normal grip force \u0026nbsp;\u0026nbsp;applied by the flexion actuators upon pressurization to 130kPa. (c) \u0026nbsp;\u0026nbsp;Frictional grip force applied by the flexion actuators upon pressurization to \u0026nbsp;\u0026nbsp;130kPa. (d) Extension torque generated by a single extension actuator upon \u0026nbsp;\u0026nbsp;pressurization to 130kPa at different flexion angles.\u003c/p\u003e","description":"","filename":"F7.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/47ceed47ed398fbb3bad74e0.png"},{"id":28877143,"identity":"1acd34a8-39a7-4255-82c1-ed28185622a0","added_by":"auto","created_at":"2022-11-09 21:33:11","extension":"png","order_by":8,"title":"Figure 8","display":"","copyAsset":false,"role":"figure","size":39323,"visible":true,"origin":"","legend":"\u003cp\u003e\u0026nbsp;Individual \u0026nbsp;\u0026nbsp;participant scores in unassisted and assisted conditions for (a) Open Hand \u0026nbsp;\u0026nbsp;tasks and (b) Closed Hand tasks.\u003c/p\u003e","description":"","filename":"F8.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/3f611ec1b556cc28349a1914.png"},{"id":28874743,"identity":"20271fb5-822d-4125-85fc-5e189d4b0cd6","added_by":"auto","created_at":"2022-11-09 21:09:11","extension":"png","order_by":9,"title":"Figure 9","display":"","copyAsset":false,"role":"figure","size":42954,"visible":true,"origin":"","legend":"\u003cp\u003e(a) Mean hand function scores across all study participants in the unassisted \u0026nbsp;\u0026nbsp;and assisted conditions, separated into tasks focusing on hand opening and \u0026nbsp;\u0026nbsp;hand closing (b) Mean grip strength across all study participants before \u0026nbsp;\u0026nbsp;commencing the trial and after the trial session. (c) Mean scores of the \u0026nbsp;\u0026nbsp;level of confidence to perform ADLs from the usability questionnaire done by \u0026nbsp;\u0026nbsp;the study participants, 5 points per object, 35 points maximum. Higher mean \u0026nbsp;\u0026nbsp;score in the assisted condition means the participants have a higher mean \u0026nbsp;\u0026nbsp;level of confidence while being assisted by the SR Glove. (d) Mean scores of \u0026nbsp;\u0026nbsp;the reliance of support from caretakers from the usability questionnaire done \u0026nbsp;\u0026nbsp;by the study participants (1 for highest reliance needed, 5 for lowest \u0026nbsp;\u0026nbsp;reliance needed). Higher mean score in the assisted condition means the \u0026nbsp;\u0026nbsp;participants feel they rely on support from others less when using the SR \u0026nbsp;\u0026nbsp;Glove.\u003c/p\u003e","description":"","filename":"F9.png","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/a29c2635a4efc33cd70ce57c.png"},{"id":43640495,"identity":"f75f7f13-674e-4728-804a-8eecbdf296bc","added_by":"auto","created_at":"2023-09-25 15:07:13","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":1900376,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-2229531/v1/94fe969c-e424-4f0d-b236-d225de0b52a8.pdf"}],"financialInterests":"No competing interests reported.","formattedTitle":"A Bidirectional Fabric-Based Soft Robotic Glove for Hand Function Assistance in Patients with Chronic Stroke","fulltext":[{"header":"I. Background","content":"\u003cp\u003eStroke is the most common cerebrovascular disease (\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e) and while the majority of stroke patients survive, up to 30% of all stroke survivors experience limited motor function recovery (\u003cspan citationid=\"CR2\" class=\"CitationRef\"\u003e2\u003c/span\u003e). Consequently, stroke is also one of the main causes of adult disability (\u003cspan citationid=\"CR3\" class=\"CitationRef\"\u003e3\u003c/span\u003e), and many victims experience a reduction of hand motor function, restricting the victim\u0026rsquo;s ability to perform activities of daily living (ADLs) independently, negatively impacting their quality of life. Stroke patients with hand impairments require physical therapy, usually involving repetitive task practice rehabilitation (\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e), to improve hand function in terms of the range of motion and strength. However, around 65% of stroke patients are still unable to incorporate their affected hand into ADLs six months after the initial onset of stroke (\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e) and only 25% of patients return to a functional level similar to that of community-matched persons who have not suffered from a stroke (\u003cspan citationid=\"CR6\" class=\"CitationRef\"\u003e6\u003c/span\u003e). In many of these chronic stroke cases, the patients enroll in step-down care services, where they undergo regular physical therapy. However, the rate of recovery of upper extremity function beyond six months after stroke is a lot slower than during the first three to six months (\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e). Therefore, there is a need for assistive devices to aid chronic stroke patients in enhancing their hand functions to perform ADLs and regain independence in their daily lives.\u003c/p\u003e \u003cp\u003eRobotics has been presented as a non-invasive method of improving hand motor function using wearable actuators such as robotic exoskeletons. These exoskeletons aid the users in moving their fingers and hands. While several robotic exoskeletons have been developed for the upper limb, many rely on linear actuators and rigid linkages (\u003cspan additionalcitationids=\"CR9\" citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR10\" class=\"CitationRef\"\u003e10\u003c/span\u003e) aligned precisely to the users\u0026rsquo; joints to transfer forces safely and efficiently. The rigid mechanical design of these exoskeletons limits portability due to their size and weight. As a result, many of these systems are stationary, designed solely for use in clinical settings and to be operated by professionals to ensure the patient\u0026rsquo;s safety. On top of that, their rigid nature leads to a reduction in patient comfort when using the exoskeletons. These conditions are not ideal to be used regularly as assistive devices.\u003c/p\u003e \u003cp\u003eLightweight, user-friendly, and portable exoskeletons that could be used in both clinical and home settings as assistive devices would help create new possibilities that would be more suited for chronic stroke patients in day-to-day life. In recent years, several wearable hand exoskeletons have been developed using soft robotics. These compliant wearable exoskeletons incorporate fabrics (\u003cspan citationid=\"CR11\" class=\"CitationRef\"\u003e11\u003c/span\u003e, \u003cspan citationid=\"CR12\" class=\"CitationRef\"\u003e12\u003c/span\u003e), polymers (\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e) and soft elastomeric actuators (\u003cspan additionalcitationids=\"CR15\" citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e) instead of traditional rigid linkages, which allow for a more comfortable experience for the patients, as well as eliminate the need for complicated mechanical setups and trained personnel to operate. These novel approaches to wearable robotics introduce the possibility for safe and user-friendly devices for daily assistance at home or therapy over prolonged periods (\u003cspan additionalcitationids=\"CR15 CR16\" citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e).\u003c/p\u003e \u003cp\u003eThe objective of this study is to investigate the viability of a fully fabric-based soft robotic (SR) glove with bidirectional (i.e., finger flexion and finger extension) actuators in assisting chronic stroke study participants with hand mobility impairments in performing ADLs. To assess the effectiveness of the SR Glove as an assistive device, the study team adapted a series of hand functional tasks based on recognized and widely used hand assessments for stroke patients. The user-friendly design of the SR Glove module allowed participants to independently control the SR Glove using the Robotic Glove Control Box with minimal training. In addition to assessing the mechanical assistance by the glove, each participant did a usability questionnaire to gather information about how using the SR Glove affects their confidence in performing the ADL tasks as well as their reliance on support for performing ADLs with and without the SR Glove.\u003c/p\u003e"},{"header":"Ii. Methods","content":"\u003cp\u003eA. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eSR Glove Module\u003c/span\u003e\u003c/p\u003e \u003cp\u003eThe SR Glove module (\u003cspan citationid=\"CR11\" class=\"CitationRef\"\u003e11\u003c/span\u003e) used in this study comprises of two parts: the SR Glove and the Robotic Glove Control Box (Fig.\u0026nbsp;1a). The Robotic Glove Control Box controls the activation of the actuators embedded in the SR Glove which in turn dictates what movements the SR Glove will assist the patient with.\u003c/p\u003e \u003cp\u003eThe SR Glove consists of the fabric glove and four pneumatic actuators that are inserted in the dorsal side of the fabric glove, aligned with the four fingers (excluding the thumb). To address the lack of fine motor control and misalignment of most stroke survivor\u0026rsquo;s thumbs, participants wore a thumb splint made of thermoset plastic to assist in holding the thumb in opposition with the four fingers (Fig.\u0026nbsp;1b). This was necessary to allow the users to perform the tasks in the trial, such as grasping objects.\u003c/p\u003e \u003cp\u003eThe actuators (Fig.\u0026nbsp;1c) in the SR Glove are bidirectional actuators that are fabricated entirely out of fabric. Each bidirectional actuator is made of two separate pneumatic actuators, the flexion actuator, and the extension actuator, which are secured together with TPU fabric. At the base of both actuators, pneumatic tube adapters are inserted to serve as air inlets. The extension actuator resembles a traditional flat fabric pneumatic actuator. The flexion actuator, while similar to the extension actuator, is folded in a corrugated manner. The design of the corrugated fold allows the flexion actuator to achieve a bending motion, mimicking normal finger flexion when it is pressurised. Before pressurisation, both actuators are compliant and flexible. This compliance in their non-pressurised state is essential in ensuring that the range of motion of the participant\u0026rsquo;s fingers is not impeded. Compared to a previous iteration (\u003cspan citationid=\"CR11\" class=\"CitationRef\"\u003e11\u003c/span\u003e), the actuators presented in this paper are fabricated with a stiffer material (500GSM Double TPU Coated 420D Nylon).\u003c/p\u003e \u003cp\u003eThe Robotic Glove Control Box (Fig.\u0026nbsp;2a) comprises a microcontroller, an electronic air pump, pressure sensors and solenoid valves. A pressure control loop (Fig.\u0026nbsp;2b) was implemented to drive the valves. Each valve is connected to an actuator in the SR Glove via pneumatic tubing. The control box also includes buttons to select the desired movement for the exercise and an LCD screen to visually assist the user in selecting the movements.\u003c/p\u003e \u003cp\u003eAs a movement is selected, the microcontroller activates the air compressor and opens the valves leading to the actuators that are meant to be activated, resulting in the desired movement of the SR Glove. The default available movements were Palmar Grasp, 2-point Pinch (index finger flexion), 3-point Tripod Pinch (index and middle finger flexion) and Extend (all four fingers extension) (Fig.\u0026nbsp;2c).\u003c/p\u003e \u003cp\u003eB. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eActuator Characterization and Force Measurements\u003c/span\u003e\u003c/p\u003e \u003cp\u003e \u003cem\u003eFlexion Actuators\u003c/em\u003e \u003c/p\u003e \u003cp\u003eThe flexion actuators were characterised and evaluated in terms of the blocked tip force and grip forces applied upon pressurisation.\u003c/p\u003e \u003cp\u003eBlocked tip force measurements were done using a customised force measurement setup, which comprised a mounting platform for the flexion actuator and a compression load cell (Fig.\u0026nbsp;3a). The force measurement setup was similar to that of previous studies (\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e, \u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e, \u003cspan citationid=\"CR19\" class=\"CitationRef\"\u003e19\u003c/span\u003e). When pressurized, the flexion actuator\u0026rsquo;s bending motion is constrained by the two adjustable straps, which minimises the non-linear effects caused by the bending of the actuator when pressurised. This in turn helps ensure that the compression load cell would read the maximum blocked tip force generated by the actuator regardless of the bend angle. The distal end of the actuator was in contact with the compression load cell. Force was measured at pressure intervals of 10kPa from 10kPa to 130kPa and repeated three times at every interval.\u003c/p\u003e \u003cp\u003eThe grip force applied by the flexion actuators was measured with a universal testing machine (Handy Tester JSV H10000) to obtain normal and frictional grip forces. The force measurement setup was similar to those reported in previous literature (\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e, \u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e, \u003cspan citationid=\"CR20\" class=\"CitationRef\"\u003e20\u003c/span\u003e). Four actuators, corresponding to the four fingers, were pressurised to 130kPa to bend and grasp a cylinder that is 80mm in diameter in a vertical orientation for frictional grip force (Fig.\u0026nbsp;3b), and horizontal orientation for normal grip force (Fig.\u0026nbsp;4). The cylinder was then pulled upwards by the universal testing machine at a fixed velocity of 8mm/s to the point where the actuators release the cylinder. The tests were repeated three times and the results were averaged.\u003c/p\u003e \u003cp\u003e \u003cem\u003eExtension Actuators\u003c/em\u003e \u003c/p\u003e \u003cp\u003eThe extension actuator is characterised by the amount of extension torque it can produce. The torque output was obtained using a customised torque testing rig, and a load cell sensor (Fig.\u0026nbsp;5). Using the torque testing rig, force exerted by the extending motion of the actuators is detected by the load cell as the mounting platform pushes against the load cell and is converted to static torque based on the distance from the load cell to the axis of rotation. The static torque of the extension actuator was measured from 0\u0026deg; to 90\u0026deg; in 10\u0026deg; intervals while the actuator was pressurized at 130kPa.\u003c/p\u003e \u003cp\u003eC. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eStudy Design\u003c/span\u003e\u003c/p\u003e \u003cp\u003eThis study evaluated the efficacy of the SR Glove as an assistive device in enhancing hand function in chronic stroke patients with limited hand recovery in step-down care (IRB Approval: LH-19-014). The trials were conducted in a case series design, whereby each participant first completed the tasks in the unassisted condition and then repeated the tasks in the assisted condition, all in a single session.\u003c/p\u003e \u003cp\u003eUnassisted hand function was first evaluated by assessing their performance in ADL tasks which can be split into three different categories. Firstly, grasping different sizes of blocks, bottles, and balls (Fig.\u0026nbsp;6a) (3 points per type of object, maximum of 9 points). Secondly, gripping and manipulating utensils (Fig.\u0026nbsp;6b) and pens (6 points maximum). Finally, pinching small cubes and coins (6 points maximum). The participants would then repeat the tasks in the assisted condition while wearing the SR Glove on their paretic hand (Fig.\u0026nbsp;6c). The participants were instructed to independently operate the SR Glove module by using their non-affected hand to press the buttons on the Robotic Glove Control Box in the assisted condition. Additionally, the participants could also use their non-affected hand to place the objects in the affected hand to stabilize the initial grip if they required it in both conditions.\u003c/p\u003e \u003cp\u003eThe trials were held at local rehabilitation centers. The participants were recruited among regular patients in the rehabilitation centers, under referral by their therapists. Every participant underwent a proper procedure of recruitment, eligibility screening, and consent taking prior to the trial and had to agree with the procedures of the trial and data collection for research purposes. Participants\u0026rsquo; demographics and research-related data were collected after successful enrolment such as gender, age, date of birth, date of diagnosis, type of stroke, duration of the stroke, and affected side.\u003c/p\u003e \u003cp\u003e After being successfully enrolled, the participants underwent pre-trial assessments to evaluate their grip strength by squeezing a hand dynamometer. After completing the hand functional tasks under both conditions, participants underwent a post-trial grip strength test. Lastly, a usability questionnaire was given to patients to evaluate their level of confidence and reliance on support in ADLs.\u003c/p\u003e \u003cp\u003eD. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eParticipants and Eligibility Criteria\u003c/span\u003e\u003c/p\u003e \u003cp\u003eA total of eight chronic stroke patients participated in the study (Table\u0026nbsp;\u003cspan refid=\"Tab1\" class=\"InternalRef\"\u003e1\u003c/span\u003e). The enrolled patients were from two local rehabilitation centers (both centers are operated by Handicaps Welfare Association, Singapore). The inclusion criteria included patients suffering from chronic stroke, either ischemic or hemorrhagic; from the ages of 20 to 90 years regardless of gender and race; unilateral upper limb impairment; ability to comprehend and follow instructions; ability to maintain upright sitting for at least 30 mins.\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab1\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 1\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eDemographics of the Chronic Stroke Patients Recruited in the Study\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"2\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e \u003cp\u003eAge\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003e70\u0026thinsp;\u0026plusmn;\u0026thinsp;8.28\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eGender\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eMale\u0026thinsp;=\u0026thinsp;5\u003c/p\u003e \u003cp\u003eFemale\u0026thinsp;=\u0026thinsp;3\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eStroke Type\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eIschemic\u0026thinsp;=\u0026thinsp;5\u003c/p\u003e \u003cp\u003eHaemorrhage\u0026thinsp;=\u0026thinsp;3\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eLocation\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eCortex\u0026thinsp;=\u0026thinsp;2 (e.g., occipital lobe, ACA)\u003c/p\u003e \u003cp\u003eSubcortex\u0026thinsp;=\u0026thinsp;7 (e.g., thalamus, basal ganglia, pons)\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eAffected Side\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eLeft\u0026thinsp;=\u0026thinsp;5\u003c/p\u003e \u003cp\u003eRight\u0026thinsp;=\u0026thinsp;3\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eDuration (years)\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e5.41\u0026thinsp;\u0026plusmn;\u0026thinsp;6.95\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eGrip Strength\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e8.29\u0026thinsp;\u0026plusmn;\u0026thinsp;10.72\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c2\" namest=\"c1\"\u003e \u003cp\u003e*Based on the voluntary movement, grip strength, and duration of the stroke, participants were classified into high and low functional groups.\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003cp\u003eWe excluded patients with recurrent stroke, unstable medical conditions, severe depression or active psychiatric disorder, epilepsy or seizure, severe spasticity (Modified Ashworth Scale\u0026thinsp;\u0026gt;\u0026thinsp;2), contracture and deformity, poor skin conditions, and cognitive impairment. In addition, pregnant women were excluded from this study. All the participants were able to make decisions by themselves and give their consent to this trial.\u003c/p\u003e \u003cp\u003eE. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eOutcome Measures\u003c/span\u003e\u003c/p\u003e \u003cp\u003e \u003cem\u003eHand Functional Tasks\u003c/em\u003e:\u003c/p\u003e \u003cp\u003eThe hand functional tasks adapted for this trial by the study team were based on recognized and widely used hand assessments for stroke patients, such as Fugl-Meyer Assessment-Upper Extremity (FMA-UE), Action Research Arm Test (ARAT), and Arm Motor Ability Test (AMAT). These hand functional tasks allowed for observation and assessment of the participant's abilities to perform ADLs with and without assistance from the SR Glove with a focus on finger extension and finger flexion. The assessments were measured on the affected hand. A higher score indicates a better performance or a higher functional level.\u003c/p\u003e \u003cp\u003e \u003cem\u003eGrip Strength\u003c/em\u003e:\u003c/p\u003e \u003cp\u003eThe maximum bare-hand grip strength of the participants was measured by using a standard Jamar Hydraulic Hand Dynamometer. Patients were asked to position the studied hand in 90 degrees of elbow flexion next to the body and squeeze the hand dynamometer three times before the trial and three times after the trial, and force measurements were averaged.\u003c/p\u003e \u003cp\u003e \u003cem\u003eUsability Questionnaire (Level of Confidence in Performing ADLs and Reliance on Support for ADLs)\u003c/em\u003e:\u003c/p\u003e \u003cp\u003e After completing the trial, a questionnaire designed by the study team was given to the participants for their feedback on the experience using the SR Glove, their level of confidence and their reliance on support from caretakers in performing ADLs while being unassisted or assisted by the SR Glove.\u003c/p\u003e \u003cp\u003eThe questionnaire had the participants indicate their confidence in performing the tasks based on the group of objects (bottle, block, pen, etc. \u0026ndash; 5 points per object, 35 points maximum), as well as their reliance on support while performing ADLs (1 for highest reliance, 5 for lowest reliance) with and without the assistance from the SR Glove.\u003c/p\u003e \u003cp\u003eF. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eData Collection and Statistical Analysis\u003c/span\u003e\u003c/p\u003e \u003cp\u003eAll trials were video recorded for rating post-test. The outcome measures and participant responses were recorded and paired (unassisted versus assisted and pre-trial versus post-trial). The responses were coded, entered, and analyzed by using Statistical Package for Social Sciences (SPSS) version 25. Descriptive results such as the mean and the standard deviation were calculated. Given the small sample size, a nonparametric statistic test, the Wilcoxon Signed Ranks test, was applied to compare the two conditions (unassisted versus assisted by SR Glove) to observe the differences in results among the patients. A significance level of \u0026le;\u0026thinsp;0.05 was used in the analyses.\u003c/p\u003e"},{"header":"Iii. Results","content":"\u003cp\u003eA. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eSR Glove Actuator Characterization\u003c/span\u003e\u003c/p\u003e \u003cp\u003e \u003cem\u003eBlocked Tip Force Measurement\u003c/em\u003e \u003c/p\u003e \u003cp\u003eThe force produced by the SR Glove Actuators increased with greater pressure. The actuators generated a maximum tip force of 22.2N at 130kPa (Fig.\u0026nbsp;7a), which is also the operating pressure of the actuators. Compared to the previous iteration of a fully fabric Soft Robotic Glove (\u003cspan citationid=\"CR11\" class=\"CitationRef\"\u003e11\u003c/span\u003e), these actuators are able to produce a greater maximum tip force at their operating pressure.\u003c/p\u003e \u003cp\u003e \u003cem\u003eGrip Force Measurements\u003c/em\u003e \u003c/p\u003e \u003cp\u003eThe grip force measurements (normal grip force and frictional grip force) showed that the SR Glove Actuators generated 60.01\u0026thinsp;\u0026plusmn;\u0026thinsp;5.50N of normal grip force and 13.53\u0026thinsp;\u0026plusmn;\u0026thinsp;1.93N of frictional grip force using a cylinder with a diameter of 80mm (Fig.\u0026nbsp;7b and 7c). The frictional grip force provided by the flexion actuators is sufficient to lift most objects of daily living, which typically do not weigh more than 1.5kg (\u003cspan citationid=\"CR21\" class=\"CitationRef\"\u003e21\u003c/span\u003e).\u003c/p\u003e \u003cp\u003e \u003cem\u003eExtension Torque\u003c/em\u003e \u003c/p\u003e \u003cp\u003eStroke patients with hand impairments typically have increased muscle tone in the finger flexors on their affected hand, leading to an unintentionally clenched hand. It is therefore essential that the SR Glove Actuator can produce enough extension torque to extend the users\u0026rsquo; fingers to grasp objects successfully.\u003c/p\u003e \u003cp\u003eA single extension actuator was found to be able to generate a maximum of 0.70Nm at 90\u0026deg; (Fig.\u0026nbsp;7d). Assuming all extension actuators generate the same amount of torque, the maximum total extension torque achieved by four actuators would be 2.8Nm at 90\u0026deg;. Based on a previous study, the total finger flexion torque of stroke patients with spastic finger flexors is estimated to be within 0.5\u0026ndash;4 Nm (\u003cspan citationid=\"CR22\" class=\"CitationRef\"\u003e22\u003c/span\u003e). Therefore, the results suggest that the SR Glove can counteract a total flexion torque of up to 2.8Nm and assist in finger extension, depending on the severity of the participant\u0026rsquo;s spasticity.\u003c/p\u003e \u003cp\u003eB. \u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003eTrial with Chronic Stroke Patients\u003c/span\u003e\u003c/p\u003e \u003cp\u003e \u003cem\u003eHand Function \u0026ndash; Finger Extension and Finger Flexion\u003c/em\u003e \u003c/p\u003e \u003cp\u003eIndividual participant scores in the hand function tasks, separated into tasks focused on hand opening and hand closing, are illustrated in Fig.\u0026nbsp;8a and 8b to provide insight into the score differences for each participant between unassisted and assisted conditions. Mean results across all test participants for the hand opening and closing tasks in unassisted and assisted conditions are also presented in Fig.\u0026nbsp;9a and Table\u0026nbsp;\u003cspan refid=\"Tab2\" class=\"InternalRef\"\u003e2\u003c/span\u003e.\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab2\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 2\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eOutcome Measures\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"12\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c5\" colnum=\"5\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c6\" colnum=\"6\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c7\" colnum=\"7\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c8\" colnum=\"8\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c9\" colnum=\"9\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c10\" colnum=\"10\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c11\" colnum=\"11\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c12\" colnum=\"12\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\" morerows=\"1\" rowspan=\"2\"\u003e \u003cp\u003eSubject\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colspan=\"2\" morerows=\"1\" nameend=\"c3\" namest=\"c2\" rowspan=\"2\"\u003e \u003cp\u003eAffected Side\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colspan=\"2\" nameend=\"c5\" namest=\"c4\"\u003e \u003cp\u003eHand Opening\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colspan=\"2\" nameend=\"c7\" namest=\"c6\"\u003e \u003cp\u003eHand Closing\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colspan=\"2\" nameend=\"c9\" namest=\"c8\"\u003e \u003cp\u003eDifference\u003c/p\u003e \u003cp\u003e(Assisted \u0026ndash; Unassisted)\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colspan=\"3\" nameend=\"c12\" namest=\"c10\"\u003e \u003cp\u003eGrip Strength (kg)\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003eUnassisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c5\"\u003e \u003cp\u003eAssisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c6\"\u003e \u003cp\u003eUnassisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c7\"\u003e \u003cp\u003eAssisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c8\"\u003e \u003cp\u003eOpen\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c9\"\u003e \u003cp\u003eClosed\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c10\"\u003e \u003cp\u003ePre\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c11\"\u003e \u003cp\u003ePost\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c12\"\u003e \u003cp\u003eDifference\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG001\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e14\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e16\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e14\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e16\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e25.50\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e24.92\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e-0.58\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG002\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eR\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e21\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e21\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e21\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e21\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e25.00\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e24.90\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e-0.1\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG003\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e21\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e7\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e17\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e21\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e10\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e3.27\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e1.27\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG004\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eR\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e9\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e19\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e13\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e16\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e10\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e4.50\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e7.76\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e3.26\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG005\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eR\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e7\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e19\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e14\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e16\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e12\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e2.33\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e1.93\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e-0.37\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG006\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e18\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e5\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e15\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e15\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e10\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG007\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e11\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e17\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e12\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e14\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e6\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e7.00\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e3.00\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e-4\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG008\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e16\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e12\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e17\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e16\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e5\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e\u0026nbsp;\u003c/td\u003e \u003ctd align=\"left\" colspan=\"2\" nameend=\"c3\" namest=\"c2\"\u003e \u003cp\u003eMean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD (total)\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e8.13\u0026thinsp;\u0026plusmn;\u0026thinsp;7.26\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e18.38\u0026thinsp;\u0026plusmn;\u0026thinsp;2.00\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e12.25\u0026thinsp;\u0026plusmn;\u0026thinsp;4.83\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e16.50\u0026thinsp;\u0026plusmn;\u0026thinsp;2.07\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e10.25\u0026thinsp;\u0026plusmn;\u0026thinsp;7.23\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c9\"\u003e \u003cp\u003e4.25\u0026thinsp;\u0026plusmn;\u0026thinsp;3.81\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c10\"\u003e \u003cp\u003e8.29\u0026thinsp;\u0026plusmn;\u0026thinsp;10.72\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c11\"\u003e \u003cp\u003e8.22\u0026thinsp;\u0026plusmn;\u0026thinsp;10.58\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c12\"\u003e \u003cp\u003e-0.07\u0026thinsp;\u0026plusmn;\u0026thinsp;2.02\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colspan=\"12\" nameend=\"c12\" namest=\"c1\"\u003e \u003cp\u003eHand Functional Tasks: the maximum score is 21.\u003c/p\u003e \u003cp\u003eAbbreviation: L: Left; R: Right; SD: Standard Deviation;\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003cp\u003eThe mean score difference between the unassisted and assisted conditions improved significantly across the group of eight participants. The mean score for Open Hand Tasks in the assisted condition (18.38\u0026thinsp;\u0026plusmn;\u0026thinsp;2.00) showed an improvement of more than double of the unassisted condition (8.13\u0026thinsp;\u0026plusmn;\u0026thinsp;7.26). This shows a significant improvement in finger extension function when participants used the SR Glove (Wilcoxon signed-rank test, Z = -2.366, \u003cem\u003ep\u003c/em\u003e\u0026thinsp;=\u0026thinsp;0.018).\u003c/p\u003e \u003cp\u003eThe mean score difference for the Closed Hand Tasks was similar. The mean unassisted score was found to be 12.25\u0026thinsp;\u0026plusmn;\u0026thinsp;4.83 while the mean score for the assisted condition was 16.50\u0026thinsp;\u0026plusmn;\u0026thinsp;2.07. This was also a significant increase in finger flexion function when participants used the SR Glove (Wilcoxon signed-rank test, Z = -2.388, \u003cem\u003ep\u003c/em\u003e\u0026thinsp;=\u0026thinsp;0.017).\u003c/p\u003e \u003cp\u003e \u003cem\u003eParticipant Grip Strength\u003c/em\u003e \u003c/p\u003e \u003cp\u003eThe mean grip strength did not exhibit a statistically significant change post-trial (\u003cem\u003ep\u003c/em\u003e\u0026thinsp;=\u0026thinsp;0.753, Table\u0026nbsp;\u003cspan refid=\"Tab3\" class=\"InternalRef\"\u003e3\u003c/span\u003e and Fig.\u0026nbsp;9b). As the trials were conducted in a single session, an increase in grip strength, which would require an extended training timeline, was not expected. Furthermore, rather than strength gaining, this trial focused on hand functional movement.\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab3\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 3\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eWilcoxon Signed Ranks Test Statistics for the Outcome Measures.\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"4\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e\u0026nbsp;\u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003eHand Opening: \u003c/p\u003e \u003cp\u003eUnassisted vs Assisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003eHand Closing: \u003c/p\u003e \u003cp\u003eUnassisted vs Assisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003eGrip Strength: \u003c/p\u003e \u003cp\u003ePre vs Post\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eZ\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e-2.366\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e-2.388\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e\u0026minus;\u0026thinsp;.314\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eAsymp. Sig. (2-tailed)\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e\u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003e0.018*\u003c/span\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e\u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003e0.017*\u003c/span\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e0.753\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colspan=\"4\" nameend=\"c4\" namest=\"c1\"\u003e \u003cp\u003e*Statistically significant, \u0026lt; 0.05.\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003cp\u003e \u003cem\u003eUsability Questionnaire\u003c/em\u003e \u003c/p\u003e \u003cp\u003e The questionnaire done by the participants after completing the trial reflected their level of confidence and reliance on support for ADLs with and without the SR Glove (Fig.\u0026nbsp;9c and 9d and Table\u0026nbsp;\u003cspan refid=\"Tab4\" class=\"InternalRef\"\u003e4\u003c/span\u003e).\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab4\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 4\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eUsability Questionnaire\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"8\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c4\" colnum=\"4\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c5\" colnum=\"5\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c6\" colnum=\"6\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c7\" colnum=\"7\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c8\" colnum=\"8\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\" morerows=\"1\" rowspan=\"2\"\u003e \u003cp\u003eSubject\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c2\" morerows=\"1\" rowspan=\"2\"\u003e \u003cp\u003eAffected Side\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colspan=\"3\" nameend=\"c5\" namest=\"c3\"\u003e \u003cp\u003eLevel of Confidence\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colspan=\"3\" nameend=\"c8\" namest=\"c6\"\u003e \u003cp\u003eReliance on Support\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003eUnassisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c4\"\u003e \u003cp\u003eAssisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c5\"\u003e \u003cp\u003eDifference\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c6\"\u003e \u003cp\u003eUnassisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c7\"\u003e \u003cp\u003eAssisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c8\"\u003e \u003cp\u003eDifference\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG001\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e20\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e21\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e1\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e4\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e-1\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG002\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eR\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e30\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e30\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e4\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e4\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG003\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e7\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e20\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e13\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e1\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG004\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eR\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e18\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e20\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e4\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG005\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eR\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e28\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e28\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e0\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG006\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e7\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e22\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e15\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e1\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG007\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e31\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e32\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e1\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e4\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e3\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e-1\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eG008\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eL\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e14\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e28\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e14\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e4\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e2\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e\u0026nbsp;\u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003eMean\u0026thinsp;\u0026plusmn;\u0026thinsp;SD (total)\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e19.38\u0026thinsp;\u0026plusmn;\u0026thinsp;9.71\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c4\"\u003e \u003cp\u003e25.13\u0026thinsp;\u0026plusmn;\u0026thinsp;4.88\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c5\"\u003e \u003cp\u003e5.75\u0026thinsp;\u0026plusmn;\u0026thinsp;6.88\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c6\"\u003e \u003cp\u003e2.63\u0026thinsp;\u0026plusmn;\u0026thinsp;1.30\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c7\"\u003e \u003cp\u003e3.38\u0026thinsp;\u0026plusmn;\u0026thinsp;0.52\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c8\"\u003e \u003cp\u003e0.75\u0026thinsp;\u0026plusmn;\u0026thinsp;1.39\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colspan=\"8\" nameend=\"c8\" namest=\"c1\"\u003e \u003cp\u003eUsability Questionnaire: the maximum score of Level of Confidence is 35; the maximum score of Reliance on Support is 5.\u003c/p\u003e \u003cp\u003eAbbreviation: L: Left; R: Right; SD: Standard Deviation;\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \u003cp\u003e Out of a maximum of 30 points, the participants rated their confidence in performing the ADL tasks in the unassisted condition with a mean score of 19.38, and a mean score of 25.13 while using the SR Glove. This increase in confidence was significant (Wilcoxon signed-rank test, Z = -2.207, \u003cem\u003ep\u003c/em\u003e\u0026thinsp;=\u0026thinsp;0.027) (Table\u0026nbsp;\u003cspan refid=\"Tab5\" class=\"InternalRef\"\u003e5\u003c/span\u003e).\u003c/p\u003e \u003cp\u003e \u003cdiv class=\"gridtable\"\u003e\u003ctable float=\"Yes\" id=\"Tab5\" border=\"1\"\u003e \u003ccaption language=\"En\"\u003e \u003cdiv class=\"CaptionNumber\"\u003eTable 5\u003c/div\u003e \u003cdiv class=\"CaptionContent\"\u003e \u003cp\u003eWilcoxon Signed Ranks Test Statistics for the Questionnaire.\u003c/p\u003e \u003c/div\u003e \u003c/caption\u003e \u003ccolgroup cols=\"3\"\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c1\" colnum=\"1\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c2\" colnum=\"2\"\u003e\u003c/div\u003e \u003cdiv align=\"left\" class=\"colspec\" colname=\"c3\" colnum=\"3\"\u003e\u003c/div\u003e \u003cthead\u003e \u003ctr\u003e \u003cth align=\"left\" colname=\"c1\"\u003e\u0026nbsp;\u003c/th\u003e \u003cth align=\"left\" colname=\"c2\"\u003e \u003cp\u003eLevel of Confidence:\u003c/p\u003e \u003cp\u003eUnassisted vs Assisted\u003c/p\u003e \u003c/th\u003e \u003cth align=\"left\" colname=\"c3\"\u003e \u003cp\u003eReliance on Support:\u003c/p\u003e \u003cp\u003eUnassisted vs Assisted\u003c/p\u003e \u003c/th\u003e \u003c/tr\u003e \u003c/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eZ\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e-2.207\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e-1.622\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colname=\"c1\"\u003e \u003cp\u003eAsymp. Sig. (2-tailed)\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c2\"\u003e \u003cp\u003e\u003cspan type=\"BoldItalic\" class=\"BoldItalic\" name=\"Emphasis\"\u003e0.027*\u003c/span\u003e\u003c/p\u003e \u003c/td\u003e \u003ctd align=\"left\" colname=\"c3\"\u003e \u003cp\u003e0.105\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003ctr\u003e \u003ctd align=\"left\" colspan=\"3\" nameend=\"c3\" namest=\"c1\"\u003e \u003cp\u003e*Statistically significant, \u0026lt; 0.05.\u003c/p\u003e \u003c/td\u003e \u003c/tr\u003e \u003c/tbody\u003e \u003c/colgroup\u003e \u003c/table\u003e\u003c/div\u003e \u003c/p\u003e \n \u003cp\u003e\u003cb\u003eFigures for \u0026ldquo;A Bidirectional Fabric-Based Soft Robotic Glove for Hand Function Assistance in Patients with Chronic Stroke\u0026rdquo;\u003c/b\u003e\u003c/p\u003e\n\u003cp\u003eAdditionally, participants felt they required less support by caretakers while using the SR Glove, with a mean score of 3.38 in the assisted condition and a mean score of 2.63 in the unassisted condition (Fig.\u0026nbsp;9d), though this was not statistically significant.\u003c/p\u003e"},{"header":"Iv. Discussion","content":"\u003cp\u003eThe viability of a fabric-based soft robotic glove in assisting chronic stroke participants with hand impairments to perform ADLs was investigated in this study. The study team adapted a series of hand functional tasks (FMA-UE, ARAT and AMAT) to assess the hand manipulation of the participants in unassisted and assisted (using SR Glove) conditions, with a focus on finger extension and flexion, as well as object manipulation. Compared to the unassisted condition, the improved scores and reduction in variability when they were assisted by the SR Glove suggest that the glove is capable of enhancing the hand function of participants with impaired unaided performance to a more functional level. These results are consistent with previous studies (\u003cspan additionalcitationids=\"CR24\" citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e). Moreover, many studies on robotics in rehabilitation present improvements in motor functions and cortical excitability in stroke patients, most likely relating to neuroplasticity (\u003cspan additionalcitationids=\"CR27\" citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e).\u003c/p\u003e \u003cp\u003eIn this study, we found that individuals with low unassisted scores (G003 and G006) experienced great benefits from using the SR Glove, with great improvements to their hand functional scores. In contrast, individuals with higher unassisted scores (G001, G002) did not experience notable benefits from the SR Glove. We believe this may be due to the ceiling effect when assessing patients with higher hand functions who generally present better motor control and less overall spasticity. This outcome suggests the SR Glove might be more beneficial for patients who suffer from severe to moderate impairment and experience decreased hand strength, an inability to initiate movement, and have spastic hands (\u003cspan citationid=\"CR29\" class=\"CitationRef\"\u003e29\u003c/span\u003e, \u003cspan citationid=\"CR30\" class=\"CitationRef\"\u003e30\u003c/span\u003e). In addition, we also observed that the relatively large standard deviation from the unassisted condition was reduced in the assisted condition, suggesting the SR Glove provided consistent assistance across all participants. This result is similar to a study done by Cappello et al. that also observed a decrease in the variability of participants\u0026rsquo; performance while wearing the soft robotic glove (\u003cspan citationid=\"CR31\" class=\"CitationRef\"\u003e31\u003c/span\u003e).\u003c/p\u003e \u003cp\u003e As is consistent among chronic stroke patients with muscle spasticity, our participants presented unintentionally clenched fists on their affected sides. To address this, the SR Glove Actuators are bidirectional and can assist the user in extending as well as flexing their fingers. Extension torque tests show the SR Glove can generate a peak torque of 2.8Nm. The participants demonstrated a lower unassisted mean score in Open Hand Tasks as compared to Closed Hand Tasks (Table\u0026nbsp;\u003cspan refid=\"Tab2\" class=\"InternalRef\"\u003e2\u003c/span\u003e), which suggests a greater difficulty for the participants to perform reliable finger extension than flexion. Assistance with the SR Glove provided a significant improvement to their Open Hand Tasks scores. G003 was unable to perform any Open Hand tasks in the unassisted condition as they could not perform finger extension without assistance. With the assistance of the SR Glove, G003 could easily extend their fingers to then grasp onto objects or release them. Reducing spasticity with robot-assisted training is also supported by a study conducted by Gandolfi et al., which suggests that it is as effective as conventional methods for spasticity reduction when combined with Botulinum toxin in chronic stroke patients with upper limb spasticity (\u003cspan citationid=\"CR32\" class=\"CitationRef\"\u003e32\u003c/span\u003e).\u003c/p\u003e \u003cp\u003eBesides the hand functional outcomes, the usability questionnaire done by the participants post-trial indicated that the participants have a higher level of confidence in performing ADLs while being assisted with the SR Glove than without. This may suggest that the participants viewed the SR Glove as an effective assistive device. Additionally, there were no responses with a decrease in confidence while using the SR Glove. Results from the questionnaire also indicated the participants felt they had a lower reliance on support from caretakers when using the SR Glove.\u003c/p\u003e \u003cp\u003eThis study assessed the participants\u0026rsquo; hand functions as well as their experience using the SR Glove Module. The participants operated the SR Glove themselves during the trial, using their non-affected hand to control the buttons on the Control Box. The intuitive design of the SR Glove module allowed them to familiarize themselves with operating it and perform the ADL tasks independently and successfully in a single session. This could have been a factor as to why the participants felt they could rely less on support from caretakers while performing ADLs with the SR Glove. Similarly, Li et al. conducted a mixed methods survey on the experiences of using rehabilitative robots and reported that stroke patients enjoyed using rehabilitative robots in therapy sessions. This was due to the rehabilitative robots providing greater variety in therapy choices, increasing the amount or intensity of treatment, and making the therapy accessible and convenient (\u003cspan citationid=\"CR33\" class=\"CitationRef\"\u003e33\u003c/span\u003e). As a result, patients have a greater motivation to practice and this increases their level of confidence in performing ADL tasks, especially when used at home (\u003cspan citationid=\"CR34\" class=\"CitationRef\"\u003e34\u003c/span\u003e). Given these advantages of rehabilitative robots, the whole system of the SR Glove is designed to be less bulky. The Control Box is made to be compact (16.4cm x 10.5cm x 14.9cm) (Fig.\u0026nbsp;1b) and lightweight, which makes it easy for transportation as well as ideal for home use. Given that users can independently operate the SR Glove as demonstrated by the participants of this study, it is potentially feasible for the SR Glove to be used as an assistive device at home.\u003c/p\u003e \u003cp\u003eStudies have also suggested that a contributing factor to the plateau seen in poststroke recovery after 6 months is a neuromuscular adaptation to a standardized outpatient regimen of exercise (\u003cspan citationid=\"CR35\" class=\"CitationRef\"\u003e35\u003c/span\u003e). To address this, introducing novel rehabilitation protocols and mass practice has shown that considerable motor improvement is still possible in the chronic stage. Using the SR Glove in therapy sessions could potentially be the novel rehabilitation protocol that chronic stroke patients in rehabilitation centers use to experience hand motor improvements in their chronic stage.\u003c/p\u003e \u003cp\u003eIn addition, the SR Glove can be adapted to suit clinical environments. For example, the SR Glove can be used as a continuous passive motion device, simply extending and flexing the affected fingers to reduce spasticity in affected fingers. Alternative methods of control, such as electromyography (EMG), electroencephalography (EEG), and inertial measurement units (IMUs), could also be explored in the future to further enhance the operation of the SR Glove by the users. Therefore, future studies will aim to investigate the efficacy of the SR Glove in rehabilitative treatments.\u003c/p\u003e \u003cp\u003eA key limitation of this study was the small sample size. We recognized that variances in characteristics, such as stroke type and time elapsed since onset of stroke, might impact the consistency of the overall results from the study. As we conducted this study amid the COVID-19 pandemic, we had to follow strict restrictions on physical contact, greatly limiting the number of participants we could recruit. Nevertheless, we managed to ascertain the importance for home-based assistance in chronic stroke patients with hand motor impairments.\u003c/p\u003e \u003cp\u003eFuture research will also need to investigate the durability and long-term usability of the glove while performing intensive testing sessions. Adjustments to the design of the SR Glove could improve the overall performance and user comfort while using the glove, such as adding silicone anti-slip material to the fingertips to aid gripping and incorporating a more suitable, thinner material on the palmar side of the glove to improve the precision of pinching and grasping objects. In addition, functional neuroimaging will provide a better understanding of the effect of robotic rehabilitation (\u003cspan additionalcitationids=\"CR27\" citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e) and could be considered for future studies. Finally, adding sensors in the SR Glove will be essential in providing biofeedback to both patients and therapists; this will improve the training effect and efficacy (\u003cspan citationid=\"CR36\" class=\"CitationRef\"\u003e36\u003c/span\u003e, \u003cspan citationid=\"CR37\" class=\"CitationRef\"\u003e37\u003c/span\u003e).\u003c/p\u003e"},{"header":"V. Conclusion","content":"\u003cp\u003eThis study provided insight into the efficacy of a fully fabric-based bidirectional soft robotic glove in improving basic hand functions in chronic stroke patients. Assessing the participants based on widely used hand assessments for stroke patients, assistance with the SR Glove showed significant improvements in finger flexion and extension when performing ADLs. Additionally, a usability questionnaire given to the participants showed that the participants had significantly greater confidence in performing the ADL tasks while using the SR Glove than without. These results, coupled with the SR Glove\u0026rsquo;s portability and intuitive operation, show that the SR Glove can be used both in rehabilitation center settings as well as in home environments as an assistive device to enhance hand function in chronic stroke patients with hand paresis.\u003c/p\u003e"},{"header":"Abbreviations","content":"\u003cp\u003eADL: Activities of daily living; SR: Soft robotics; FMA-UE: Fugl-Meyer Assessment-Upper Extremity; ARAT: Action Research Arm Test; AMAT: Arm Motor Ability Test. \u003c/p\u003e"},{"header":"Declarations","content":"\u003cp\u003e\u003cstrong\u003eAcknowledgement\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThe authors would like to express their appreciation of the study participants for their willingness to take part in the study and for their feedback. We also acknowledge the occupational and physiotherapists at Handicaps Welfare Association for their hospitality and for their aid in the recruitment of participants.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability of data and materials\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eData and materials can be made available upon request to the authors.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor\u0026rsquo;s contributions\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eHSL designed the trial that was done with the participants. DYLL built the soft robotic glove and the control box and performed the experiments on the soft robotic glove. HSL and DYLL performed the experiments with the participants, analyzed and interpreted the data and wrote the manuscript. RCHY provided guidance over the entire study. All authors reviewed the manuscript and provided feedback on the manuscript. All authors read and approved the final manuscript.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eEthics Approval and Consent to Participate\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThis work was funded by the Tote Board Enabling Lives Initiative (TB-ELI) Grant. Ethics approval was obtained from the Institutional Review Board (IRB Approval: LH-19-014), National University of Singapore. All patients signed a consent form as part of the agreement. They were recruited under the Human ethics committee\u0026apos;s approval, the Institutional Review Board (IRB), National University of Singapore.\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eConsent for publication\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eWritten informed consent for publication was obtained from the participants involved in the study\u003c/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompeting interests\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eThe authors declare that they have no competing interests.\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\u003cli\u003e\u003cspan\u003eBrain's Diseases of the Nervous System. Donaghy M, editor: Oxford University Press; 2009 01 Jul 2011.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLanghorne P, Coupar F, Pollock A. Motor recovery after stroke: a systematic review. Lancet Neurol. 2009;8(8):741\u0026ndash;54.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eTsao CW, Aday AW, Almarzooq ZI, Alonso A, Beaton AZ, Bittencourt MS, et al. Heart Disease and Stroke Statistics-2022 Update: A Report From the American Heart Association. Circulation. 2022;145(8):e153\u0026ndash;639.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMichaelsen SM, Dannenbaum R, Levin MF. Task-specific training with trunk restraint on arm recovery in stroke: randomized control trial. Stroke. 2006;37(1):186\u0026ndash;92.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKwakkel G, Kollen BJ, van der Grond J, Prevo AJ. Probability of regaining dexterity in the flaccid upper limb: impact of severity of paresis and time since onset in acute stroke. Stroke. 2003;34(9):2181\u0026ndash;6.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLai SM, Studenski S, Duncan PW, Perera S. Persisting consequences of stroke measured by the Stroke Impact Scale. Stroke. 2002;33(7):1840\u0026ndash;4.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003evan Kuijk AA, Pasman JW, Hendricks HT, Zwarts MJ, Geurts AC. Predicting hand motor recovery in severe stroke: the role of motor evoked potentials in relation to early clinical assessment. Neurorehabil Neural Repair. 2009;23(1):45\u0026ndash;51.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWorsnopp TT, Peshkin MA, Colgate JE, Kamper DG, editors. An Actuated Finger Exoskeleton for Hand Rehabilitation Following Stroke. 2007 IEEE 10th International Conference on Rehabilitation Robotics; 2007 13\u0026ndash;15 June 2007.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAtes S, Haarman CJW, Stienen AHA. SCRIPT passive orthosis: design of interactive hand and wrist exoskeleton for rehabilitation at home after stroke. Auton Robots. 2017;41(3):711\u0026ndash;23.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePolotto A, Modulo F, Flumian F, Xiao ZG, Boscariol P, Menon C, editors. Index finger rehabilitation/assistive device. 2012 4th IEEE RAS \u0026amp; EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob); 2012 24\u0026ndash;27 June 2012.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYap HK, Khin PM, Koh TH, Sun Y, Liang X, Lim JH, et al. A Fully Fabric-Based Bidirectional Soft Robotic Glove for Assistance and Rehabilitation of Hand Impaired Patients. IEEE Rob Autom Lett. 2017;2(3):1383\u0026ndash;90.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCappello L, Galloway KC, Sanan S, Wagner DA, Granberry R, Engelhardt S, et al. Exploiting Textile Mechanical Anisotropy for Fabric-Based Pneumatic Actuators. Soft Robot. 2018;5(5):662\u0026ndash;74.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKang BB, Choi H, Lee H, Cho KJ. Exo-Glove Poly II. A Polymer-Based Soft Wearable Robot for the Hand with a Tendon-Driven Actuation System. Soft Robot. 2019;6(2):214\u0026ndash;27.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePolygerinos P, Galloway KC, Sanan S, Herman M, Walsh CJ, editors. EMG controlled soft robotic glove for assistance during activities of daily living. 2015 IEEE International Conference on Rehabilitation Robotics (ICORR); 2015 11\u0026ndash;14 Aug. 2015.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYap HK, Lim JH, Nasrallah F, Cho Hong Goh J, Yeow CH. Characterisation and evaluation of soft elastomeric actuators for hand assistive and rehabilitation applications. J Med Eng Technol. 2016;40(4):199\u0026ndash;209.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePolygerinos P, Wang Z, Galloway KC, Wood RJ, Walsh CJ. Soft robotic glove for combined assistance and at-home rehabilitation. Robot Auton Syst. 2015;73:135\u0026ndash;43.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYap HK, Mao A, Goh JCH, Yeow CH. Design of a wearable FMG sensing system for user intent detection during hand rehabilitation with a soft robotic glove. 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob); 2016 26\u0026ndash;29 June 2016.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePolygerinos P, Wang Z, Overvelde JTB, Galloway KC, Wood RJ, Bertoldi K, et al. Modeling of Soft Fiber-Reinforced Bending Actuators. IEEE Trans Robot. 2015;31(3):778\u0026ndash;89.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYap HK, Sebastian F, Wiedeman C, Yeow CH. Design and characterization of low-cost fabric-based flat pneumatic actuators for soft assistive glove application. 2017 International Conference on Rehabilitation Robotics (ICORR); 2017 17\u0026ndash;20 July 2017.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAng BWK, Yeow CH. Print-it-Yourself (PIY) glove: A fully 3D printed soft robotic hand rehabilitative and assistive exoskeleton for stroke patients. 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS); 2017 24\u0026ndash;28 Sept. 2017.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMatheus K, Dollar AM, editors. Benchmarking grasping and manipulation: Properties of the Objects of Daily Living. 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems; 2010 18\u0026ndash;22 Oct. 2010.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKamper DG, Rymer WZ. Quantitative features of the stretch response of extrinsic finger muscles in hemiparetic stroke. Muscle Nerve. 2000;23(6):954\u0026ndash;61.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eVanoglio F, Bernocchi P, Mul\u0026egrave; C, Garofali F, Mora C, Taveggia G, et al. Feasibility and efficacy of a robotic device for hand rehabilitation in hemiplegic stroke patients: a randomized pilot controlled study. Clin Rehabil. 2017;31(3):351\u0026ndash;60.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSusanto EA, Tong RK, Ockenfeld C, Ho NS. Efficacy of robot-assisted fingers training in chronic stroke survivors: a pilot randomized-controlled trial. J Neuroeng Rehabil. 2015;12:42.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBustamante Valles K, Montes S, Madrigal MdJ, Burciaga A, Mart\u0026iacute;nez ME, Johnson MJ. Technology-assisted stroke rehabilitation in Mexico: a pilot randomized trial comparing traditional therapy to circuit training in a Robot/technology-assisted therapy gym. J Neuroeng Rehabil. 2016;13(1):83.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSingh N, Saini M, Kumar N, Srivastava MVP, Mehndiratta A. Evidence of neuroplasticity with robotic hand exoskeleton for post-stroke rehabilitation: a randomized controlled trial. J Neuroeng Rehabil. 2021;18(1):76.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNasrallah FA, Mohamed AZ, Yap HK, Lai HS, Yeow CH, Lim JH. Effect of proprioceptive stimulation using a soft robotic glove on motor activation and brain connectivity in stroke survivors. J Neural Eng. 2021.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMehrholz J, Pollock A, Pohl M, Kugler J, Elsner B. Systematic review with network meta-analysis of randomized controlled trials of robotic-assisted arm training for improving activities of daily living and upper limb function after stroke. J Neuroeng Rehabil. 2020;17(1):83.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHijikata N, Kawakami M, Ishii R, Tsuzuki K, Nakamura T, Okuyama K, et al. Item Difficulty of Fugl-Meyer Assessment for Upper Extremity in Persons With Chronic Stroke With Moderate-to-Severe Upper Limb Impairment. Frontiers in Neurology. 2020;11.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSullivan KJ, Tilson JK, Cen SY, Rose DK, Hershberg J, Correa A, et al. Fugl-Meyer Assess Sensorimotor Function After Stroke Stroke. 2011;42(2):427\u0026ndash;32.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCappello L, Meyer JT, Galloway KC, Peisner JD, Granberry R, Wagner DA, et al. Assisting hand function after spinal cord injury with a fabric-based soft robotic glove. J Neuroeng Rehabil. 2018;15(1):59.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGandolfi M, Val\u0026egrave; N, Dimitrova EK, Mazzoleni S, Battini E, Filippetti M, et al. Effectiveness of Robot-Assisted Upper Limb Training on Spasticity, Function and Muscle Activity in Chronic Stroke Patients Treated With Botulinum Toxin: A Randomized Single-Blinded Controlled Trial. Frontiers in Neurology. 2019;10.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLi L, Tyson S, Weightman A. Professionals' Views and Experiences of Using Rehabilitation Robotics With Stroke Survivors: A Mixed Methods Survey. Front Med Technol. 2021;3:780090.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAkbari A, Haghverd F, Behbahani S. Robotic Home-Based Rehabilitation Systems Design: From a Literature Review to a Conceptual Framework for Community-Based Remote Therapy During COVID-19 Pandemic. Frontiers in Robotics and AI. 2021;8.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePage SJ, Gater DR, Bach YRP. Reconsidering the motor recovery plateau in stroke rehabilitation. Arch Phys Med Rehabil. 2004;85(8):1377\u0026ndash;81.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMaceira-Elvira P, Popa T, Schmid A-C, Hummel FC. Wearable technology in stroke rehabilitation: towards improved diagnosis and treatment of upper-limb motor impairment. J Neuroeng Rehabil. 2019;16(1):142.\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eShi XQ, Heung HL, Tang ZQ, Tong KY, Li Z. Verification of Finger Joint Stiffness Estimation Method With Soft Robotic Actuator. Frontiers in Bioengineering and Biotechnology. 2020;8.\u003c/span\u003e\u003c/li\u003e\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasAdminPriorityOnWorkflow":false,"hasManuscriptDocX":true,"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hasAnyPriority":false,"hideJournal":false,"highlight":"","institution":"","isAcceptedByJournal":true,"isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"isWithdrawnOrRetracted":false,"journal":{"display":true,"email":"
[email protected]","identity":"journal-of-neuroengineering-and-rehabilitation","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"jner","sideBox":"Learn more about [Journal of NeuroEngineering and Rehabilitation](http://jneuroengrehab.biomedcentral.com/)","snPcode":"12984","submissionUrl":"https://submission.nature.com/new-submission/12984/3","title":"Journal of NeuroEngineering and Rehabilitation","twitterHandle":"@BioMedCentral","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"em","reportingPortfolio":"BMC/SO AJ","inReviewEnabled":true,"inReviewRevisionsEnabled":true},"keywords":"Soft robotics, Chronic stroke, Activities of daily living, Assistive device, Fabric-based actuator, Case Series","lastPublishedDoi":"10.21203/rs.3.rs-2229531/v1","lastPublishedDoiUrl":"https://doi.org/10.21203/rs.3.rs-2229531/v1","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003ch2\u003eBackground\u003c/h2\u003e \u003cp\u003eChronic stroke patients usually experience reduced hand functions, impeding their ability to perform activities of daily living (ADLs) independently. Additionally, improvements in hand functions by physical therapy beyond six months after the initial onset of stroke are much slower than in the earlier months. As such, chronic stroke patients could benefit from an assistive device to enhance their hand functions, allowing them to perform ADLs independently daily. In recent years, soft robotics has provided a novel approach to assistive devices for motor impaired individuals, offering more compliant and lightweight alternatives to traditional robotic devices. The scope of this study is to demonstrate the viability of a fabric-based soft robotic (SR) glove with bidirectional actuators in assisting chronic stroke study participants with hand impairments in performing ADLs.\u003c/p\u003e\u003ch2\u003eMethods\u003c/h2\u003e \u003cp\u003eForce and torque measurement tests were conducted to characterize the SR Glove, and hand functional tasks were given to eight chronic stroke patients to assess the efficacy of the SR Glove as an assistive device. The tasks involved object manipulation tasks that simulate ADLs, and the series of tasks was done by the participants once without assistance for baseline data, and once while using the SR Glove. A usability questionnaire was also given to each participant after the tasks were done to gain insight into how the SR Glove impacts their confidence and reliance on support while performing ADLs.\u003c/p\u003e\u003ch2\u003eResults\u003c/h2\u003e \u003cp\u003e The SR Glove improved the participants\u0026rsquo; manipulation of objects in ADL tasks. Difference in mean scores between the unassisted and assisted conditions was significant across all participants. Additionally, the usability questionnaire showed the participants felt more confident and less reliant on support while using the SR Glove to perform ADLs than without the SR Glove.\u003c/p\u003e\u003ch2\u003eConclusions\u003c/h2\u003e \u003cp\u003eThe results from this study demonstrated that the SR Glove is a viable option to assist hand function in chronic stroke patients who suffer from hand motor impairments.\u003c/p\u003e","manuscriptTitle":"A Bidirectional Fabric-Based Soft Robotic Glove for Hand Function Assistance in Patients with Chronic Stroke","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2022-11-09 21:09:06","doi":"10.21203/rs.3.rs-2229531/v1","editorialEvents":[{"type":"communityComments","content":0},{"type":"decision","content":"Major revision","date":"2023-01-12T08:55:41+00:00","index":"","fulltext":""},{"type":"editorInvitedReview","content":"","date":"2022-12-01T21:30:48+00:00","index":"hide","fulltext":""},{"type":"reviewerAgreed","content":"869f873c-578e-4266-a033-8e20c699e2dc","date":"2022-11-28T13:01:43+00:00","index":"hide","fulltext":""},{"type":"reviewersInvited","content":"","date":"2022-11-28T10:38:32+00:00","index":"","fulltext":""},{"type":"editorAssigned","content":"","date":"2022-11-04T08:20:15+00:00","index":"","fulltext":""},{"type":"checksComplete","content":"","date":"2022-11-04T08:20:14+00:00","index":"","fulltext":""},{"type":"submitted","content":"Journal of NeuroEngineering and Rehabilitation","date":"2022-11-02T09:44:40+00:00","index":"","fulltext":""}],"status":"published","journal":{"display":true,"email":"
[email protected]","identity":"journal-of-neuroengineering-and-rehabilitation","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":false,"externalIdentity":"jner","sideBox":"Learn more about [Journal of NeuroEngineering and Rehabilitation](http://jneuroengrehab.biomedcentral.com/)","snPcode":"12984","submissionUrl":"https://submission.nature.com/new-submission/12984/3","title":"Journal of NeuroEngineering and Rehabilitation","twitterHandle":"@BioMedCentral","acdcEnabled":true,"dfaEnabled":true,"editorialSystem":"em","reportingPortfolio":"BMC/SO AJ","inReviewEnabled":true,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"2cfa1703-21e1-475e-83e6-c174d262f692","owner":[],"postedDate":"November 9th, 2022","published":true,"recentEditorialEvents":[],"rejectedJournal":[],"revision":"","amendment":"","status":"published-in-journal","subjectAreas":[],"tags":[],"updatedAt":"2023-09-25T15:03:44+00:00","versionOfRecord":{"articleIdentity":"rs-2229531","link":"https://doi.org/10.1186/s12984-023-01250-4","journal":{"identity":"journal-of-neuroengineering-and-rehabilitation","isVorOnly":false,"title":"Journal of NeuroEngineering and Rehabilitation"},"publishedOn":"2023-09-21 15:00:36","publishedOnDateReadable":"September 21st, 2023"},"versionCreatedAt":"2022-11-09 21:09:06","video":"","vorDoi":"10.1186/s12984-023-01250-4","vorDoiUrl":"https://doi.org/10.1186/s12984-023-01250-4","workflowStages":[]},"version":"v1","identity":"rs-2229531","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"redirect":"/article/rs-2229531","identity":"rs-2229531","version":["v1"]},"buildId":"7rjqhiLT3MXkJMwkYKINL","isFallback":false,"isExperimentalCompile":false,"dynamicIds":[84888],"gssp":true,"scriptLoader":[]}
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.