Abstract
The electron cyclotron emission (ECE) imaging to determine the electron temperature profile by measuring the intensity of each frequency of ECE. This system uses a wide-band two-dimensional horn-antenna mixer array (HMA) whose frequency response is between 50 and 110 GHz and the ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.