Clinically Delivered Treatment for Glioma Patients on a Hybrid Magnetic Resonance Imaging (MRI)-Linear Accelerator (MR-Linac) and a Cone Beam CT (CBCT)-Guided Linac: Dosimetric Comparisons with In Vivo Skin Dose Correlation

preprint OA: closed CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Abstract Background Magnetic Resonance Imaging (MRI)-Linear Accelerator (MR-Linac) radiotherapy requires special consideration for secondary electron interactions within the magnetic field, which can alter dose deposition at air-tissue interfaces. Methods Thirty-seven consecutive glioma patients treated during their radiotherapy course with at least one fraction delivered on MR-Linac or Cone Beam CT (CBCT)-guided Linac, were analyzed. Treatment planning for both systems were completed prior to radiotherapy initiation and approved for clinical delivery using commercial treatment planning systems (TPS): a Monte Carlo calculation-based or convolution calculation-based TPS for MR-Linac or CBCT-Linac, respectively. Dosimetric parameters for planning target volume (PTV), organs-at-risk (OARs), and air-tissue interface were compared. In vivo skin dose during a single fraction of MR-Linac and CBCT-Linac treatment was measured using an Optically Stimulated Luminescent Dosimeter (OSLD) and correlated with TPS skin dose. Results Monte Carlo-based MR-Linac plans and convolution-based CBCT-Linac plans exhibited minimal differences in PTV and OAR parameters. However, MR-Linac plans had greater doses within tissues surrounding air cavities (1.52 Gy higher mean Dmean, p < 0.0001) and skin (1.10 Gy higher mean Dmean, p < 0.0001). In vivo OSLD skin readings were 14.5% greater for MR-Linac treatments (p = 0.0027), and were more accurately predicted by Monte Carlo-based calculation (ρ = 0.95, p < 0.0001) vs. convolution-based (ρ = 0.80, p = 0.0096). Conclusions The magnetic field’s dosimetric impact was minimal for PTV and OARs in glioma as compared to standard CBCT-Linac treatment plans. However, skin doses were significantly greater with the MR-Linac and correlated with in vivo measurements. Future MR-Linac planning processes are being designed to account for skin dosimetry and treatment delivery.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-4.0