Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI

preprint OA: closed CC-BY-NC-ND-4.0
📄 Open PDF View at publisher

Abstract

ABSTRACT Background Achieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. Purpose Magnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. Study Type Prospective observational study Subjects A spherical isotropic diffusion phantom, and a single human control volunteer Field Strength/Sequence 3T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm 2 with 12, 32, and 384 diffusion gradient directions per shell. Assessment We compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. Statistical Tests Wilcoxon rank-sum test between uncorrected and corrected data. Results In phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p<0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p<0.05). Conclusion Our method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-NC-ND-4.0