Fogarty-assisted transcatheter embolization of a large renal high-flow arteriovenous fistula
preprint
OA: closed
CC-BY-4.0
Abstract
Abstract Background: Renal arteriovenous fistulas and its complications may involve high output heart failure, hematuria or lethal hemorrhage.Case presentation: This case report covers the case of a 65-year-old male patient with a large renal high-flow arteriovenous fistula of the right kidney (RAVF), treated with balloon-assisted coil and liquid (n-Butyl Cyanoacrylate) embolization. By use of ballon-occlusion with an over-the-wire Fogarty catheter and advancement of a microcatheter through the lumen distal to the balloon during the transcatheter embolization of a high-flow RAVF, control of arterial blood flow is feasible by temporary occlusion of the afferent artery. This technique of flow modulation facilitates controlled deployment of embolization materials and avoids the risk of inadvertent distal embolization by use of only one 6-French (F) arterial sheath.Conclusion: Balloon-assisted embolization using a Fogarty occlusion catheter represents a feasible, safe and effective approach for the treatment of large, high-flow arteriovenous fistulas of the kidney.
My notes (saved in your browser only)
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-05-19T01:45:01.086888+00:00
- unpaywall
- last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-4.0