Scoping Review of Regulatory Transparency in AI-based Radiology Software: Analysis of PMDA-approved SaMD Products

preprint OA: closed CC-BY-4.0
📄 Open PDF Full text JSON View at publisher
AI-generated deep summary by claude@2026-07, 2026-07-06 · read from full text

This scoping review systematically evaluated the package inserts of PMDA-approved AI-based Software as a Medical Device (SaMD) products in Japan, including all PMDA approvals up to December 31, 2024, and extracted product characteristics, study designs, demographics, and performance metrics. Among 151 approved SaMD products, 40 used AI and 20 were specifically for radiology, and the review found major transparency gaps—most notably that no product provided complete case demographic data, while reported performance metrics (e.g., sensitivity) varied widely across standalone and physician-assisted studies. A key limitation is that the analysis relied on what was disclosed in package inserts rather than verifying clinical evidence quality beyond these documents. Relevance to endometriosis: the paper does not explicitly discuss endometriosis or adenomyosis; it focuses on regulatory transparency for AI radiology SaMD, which is included in the corpus via keyword match in the upstream search index.

Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works

Abstract

Background The integration of artificial intelligence (AI) in radiology has accelerated globally, with Japan’s Pharmaceuticals and Medical Devices Agency (PMDA) approving numerous AI-based Software as a Medical Device (SaMD) products. However, the transparency and completeness of clinical evidence available to healthcare providers remain unclear. Purpose To systematically evaluate the availability and transparency of clinical evidence in package inserts of PMDA-approved AI-based radiology SaMD products, identifying gaps that may impact clinical implementation. Materials and Methods We conducted a systematic review of all PMDA-approved SaMD products as of December 31, 2024. Products were included if they utilized AI technology and were classified for radiology applications. Data extraction focused on product characteristics, study designs, demographic information, and performance metrics. Results Of 151 approved SaMD products, 40 utilized AI technology, with 20 specifically designed for radiology applications. Critical gaps were identified in demographic reporting, with no products providing complete case demographic data. Performance metrics varied widely, with sensitivity ranging from 67.7% to 100% in standalone studies. Physician-assisted studies consistently demonstrated performance improvements but lacked stratified results by characteristics in all cases. Conclusion Current package insert requirements provide insufficient transparency for evidence-based clinical implementation of AI-based radiology software. Enhanced regulatory frameworks and industry-led initiatives for comprehensive validation are essential for safe and effective AI deployment in Japanese healthcare.
Full text 41,018 characters · extracted from preprint-html · click to expand
Scoping Review of Regulatory Transparency in AI-based Radiology Software: Analysis of PMDA-approved SaMD Products | medRxiv /* */ /* */ <!-- <!-- /*! * yepnope1.5.4 * (c) WTFPL, GPLv2 */ (function(a,b,c){function d(a){return"[object Function]"==o.call(a)}function e(a){return"string"==typeof a}function f(){}function g(a){return!a||"loaded"==a||"complete"==a||"uninitialized"==a}function h(){var a=p.shift();q=1,a?a.t?m(function(){("c"==a.t?B.injectCss:B.injectJs)(a.s,0,a.a,a.x,a.e,1)},0):(a(),h()):q=0}function i(a,c,d,e,f,i,j){function k(b){if(!o&&g(l.readyState)&&(u.r=o=1,!q&&h(),l.onload=l.onreadystatechange=null,b)){"img"!=a&&m(function(){t.removeChild(l)},50);for(var d in y[c])y[c].hasOwnProperty(d)&&y[c][d].onload()}}var j=j||B.errorTimeout,l=b.createElement(a),o=0,r=0,u={t:d,s:c,e:f,a:i,x:j};1===y[c]&&(r=1,y[c]=[]),"object"==a?l.data=c:(l.src=c,l.type=a),l.width=l.height="0",l.onerror=l.onload=l.onreadystatechange=function(){k.call(this,r)},p.splice(e,0,u),"img"!=a&&(r||2===y[c]?(t.insertBefore(l,s?null:n),m(k,j)):y[c].push(l))}function j(a,b,c,d,f){return q=0,b=b||"j",e(a)?i("c"==b?v:u,a,b,this.i++,c,d,f):(p.splice(this.i++,0,a),1==p.length&&h()),this}function k(){var a=B;return a.loader={load:j,i:0},a}var l=b.documentElement,m=a.setTimeout,n=b.getElementsByTagName("script")[0],o={}.toString,p=[],q=0,r="MozAppearance"in l.style,s=r&&!!b.createRange().compareNode,t=s?l:n.parentNode,l=a.opera&&"[object Opera]"==o.call(a.opera),l=!!b.attachEvent&&!l,u=r?"object":l?"script":"img",v=l?"script":u,w=Array.isArray||function(a){return"[object Array]"==o.call(a)},x=[],y={},z={timeout:function(a,b){return b.length&&(a.timeout=b[0]),a}},A,B;B=function(a){function b(a){var a=a.split("!"),b=x.length,c=a.pop(),d=a.length,c={url:c,origUrl:c,prefixes:a},e,f,g;for(f=0;f<d;f++)g=a[f].split("="),(e=z[g.shift()])&&(c=e(c,g));for(f=0;f<b;f++)c=x[f](c);return c}function g(a,e,f,g,h){var i=b(a),j=i.autoCallback;i.url.split(".").pop().split("?").shift(),i.bypass||(e&&(e=d(e)?e:e[a]||e[g]||e[a.split("/").pop().split("?")[0]]),i.instead?i.instead(a,e,f,g,h):(y[i.url]?i.noexec=!0:y[i.url]=1,f.load(i.url,i.forceCSS||!i.forceJS&&"css"==i.url.split(".").pop().split("?").shift()?"c":c,i.noexec,i.attrs,i.timeout),(d(e)||d(j))&&f.load(function(){k(),e&&e(i.origUrl,h,g),j&&j(i.origUrl,h,g),y[i.url]=2})))}function h(a,b){function c(a,c){if(a){if(e(a))c||(j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}),g(a,j,b,0,h);else if(Object(a)===a)for(n in m=function(){var b=0,c;for(c in a)a.hasOwnProperty(c)&&b++;return b}(),a)a.hasOwnProperty(n)&&(!c&&!--m&&(d(j)?j=function(){var a=[].slice.call(arguments);k.apply(this,a),l()}:j[n]=function(a){return function(){var b=[].slice.call(arguments);a&&a.apply(this,b),l()}}(k[n])),g(a[n],j,b,n,h))}else!c&&l()}var h=!!a.test,i=a.load||a.both,j=a.callback||f,k=j,l=a.complete||f,m,n;c(h?a.yep:a.nope,!!i),i&&c(i)}var i,j,l=this.yepnope.loader;if(e(a))g(a,0,l,0);else if(w(a))for(i=0;i (function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0];var j=d.createElement(s);var dl=l!='dataLayer'?'&l='+l:'';j.src='//www.googletagmanager.com/gtm.js?id='+i+dl;j.type='text/javascript';j.async=true;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-P4HH5NV'); Skip to main content Home About Submit ALERTS / RSS Search for this keyword Advanced Search Scoping Review of Regulatory Transparency in AI-based Radiology Software: Analysis of PMDA-approved SaMD Products View ORCID Profile Tomohiro Kikuchi , View ORCID Profile Shannon L Walston , View ORCID Profile Hirotaka Takita , View ORCID Profile Yasuhito Mitsuyama , View ORCID Profile Rintaro Ito , View ORCID Profile Masahiro Hashimoto , View ORCID Profile Takeshi Nakaura , Hiroaki Hyakutake , Sho Kawabe , View ORCID Profile Harushi Mori , View ORCID Profile Daiju Ueda doi: https://doi.org/10.1101/2025.10.02.25336333 Tomohiro Kikuchi 1 Department of Radiology, Jichi Medical University , 3311-1, Yakushi-ji, Shimotsuke-shi, Tochigi, 329-0498, Japan 2 Medical AI Promotion Institute Co., Ltd., Life Science Building , 12-9 Nihonbashi Odemmachi, Chuo-ku, Tokyo, Japan MD, MPH, PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Tomohiro Kikuchi Shannon L Walston 3 Department of Artificial Intelligence, Graduate School of Medicine, Osaka Metropolitan University , Asahi-machi, Abeno-ku, Osaka 545-8585, Japan PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Shannon L Walston Hirotaka Takita 4 Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka Metropolitan University , 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585, Japan MD, PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Hirotaka Takita Yasuhito Mitsuyama 4 Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka Metropolitan University , 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585, Japan 5 Smart Data and Knowledge Services Department, German Research Center for Artificial Intelligence (DFKI GmbH) , 67663 Kaiserslautern, Germany MD, PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Yasuhito Mitsuyama Rintaro Ito 6 Department of Innovative BioMedical Visualization,Nagoya University Graduate School of Medicine , Showa-ku, Nagoya, Japan MD, PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Rintaro Ito Masahiro Hashimoto 7 Department of Radiology, Keio University School of Medicine , Shinjukuku, Tokyo, Japan MD PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Masahiro Hashimoto Takeshi Nakaura 8 Department of Diagnostic Radiology, Kumamoto University Graduate School of Medicine , Chuo-ku, Kumamoto, Japan MD, PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Takeshi Nakaura Hiroaki Hyakutake 2 Medical AI Promotion Institute Co., Ltd., Life Science Building , 12-9 Nihonbashi Odemmachi, Chuo-ku, Tokyo, Japan Find this author on Google Scholar Find this author on PubMed Search for this author on this site Sho Kawabe 2 Medical AI Promotion Institute Co., Ltd., Life Science Building , 12-9 Nihonbashi Odemmachi, Chuo-ku, Tokyo, Japan MBA Find this author on Google Scholar Find this author on PubMed Search for this author on this site Harushi Mori 1 Department of Radiology, Jichi Medical University , 3311-1, Yakushi-ji, Shimotsuke-shi, Tochigi, 329-0498, Japan MD, PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Harushi Mori Daiju Ueda 2 Medical AI Promotion Institute Co., Ltd., Life Science Building , 12-9 Nihonbashi Odemmachi, Chuo-ku, Tokyo, Japan 3 Department of Artificial Intelligence, Graduate School of Medicine, Osaka Metropolitan University , Asahi-machi, Abeno-ku, Osaka 545-8585, Japan 9 Center for Health Science Innovation, Osaka Metropolitan University , Asahi-machi, Abeno-ku, Osaka 545-8585, Japan MD, PhD Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Daiju Ueda For correspondence: daiju.ueda{at}mapi-jp.org Abstract Full Text Info/History Metrics Data/Code Preview PDF Abstract Background The integration of artificial intelligence (AI) in radiology has accelerated globally, with Japan’s Pharmaceuticals and Medical Devices Agency (PMDA) approving numerous AI-based Software as a Medical Device (SaMD) products. However, the transparency and completeness of clinical evidence available to healthcare providers remain unclear. Purpose To systematically evaluate the availability and transparency of clinical evidence in package inserts of PMDA-approved AI-based radiology SaMD products, identifying gaps that may impact clinical implementation. Materials and Methods We conducted a systematic review of all PMDA-approved SaMD products as of December 31, 2024. Products were included if they utilized AI technology and were classified for radiology applications. Data extraction focused on product characteristics, study designs, demographic information, and performance metrics. Results Of 151 approved SaMD products, 40 utilized AI technology, with 20 specifically designed for radiology applications. Critical gaps were identified in demographic reporting, with no products providing complete case demographic data. Performance metrics varied widely, with sensitivity ranging from 67.7% to 100% in standalone studies. Physician-assisted studies consistently demonstrated performance improvements but lacked stratified results by characteristics in all cases. Conclusion Current package insert requirements provide insufficient transparency for evidence-based clinical implementation of AI-based radiology software. Enhanced regulatory frameworks and industry-led initiatives for comprehensive validation are essential for safe and effective AI deployment in Japanese healthcare. Introduction The rapid advancement of artificial intelligence (AI) technologies has fundamentally transformed the landscape of medical imaging and radiology practice worldwide [ 1 ]. In Japan, the Pharmaceuticals and Medical Devices Agency (PMDA) has established itself as a pioneering regulatory body in the approval of AI-based Software as Medical Device (SaMD) products, with a notable concentration in radiology applications[ 2 ]. As of 2024, Japan is an early adopter of AI-based medical devices, with a dedicated SaMD review office and dozens of approved products, reflecting its technologically advanced healthcare system and progressive regulatory framework [ 3 ]. The integration of AI into clinical radiology practice presents unique challenges that extend beyond traditional medical device implementation. Unlike conventional imaging equipment, AI-based software systems exhibit performance characteristics that can vary significantly based on patient demographics, imaging protocols, and institutional practices [ 4 ]. This variability necessitates a higher standard of transparency in clinical evidence to enable healthcare providers to make informed decisions about implementation and to understand the limitations of these technologies in their specific clinical contexts [ 5 ]. Package inserts, known as “tenpu-bunsho” in Japanese regulatory terminology, serve as the primary source of product information for clinicians and healthcare institutions [ 6 ]. These documents are legally required to contain essential information about the safety, efficacy, and proper use of medical devices [ 7 ]. For AI-based SaMD products, package inserts represent a critical communication channel between manufacturers, regulators, and end-users, theoretically providing the evidence base necessary for safe and effective clinical implementation. However, the rapid pace of AI development and deployment has outstripped the evolution of regulatory documentation standards. International studies have highlighted significant variations in the quality and completeness of clinical evidence provided for AI-based medical devices, with particular concerns about the generalizability of performance claims across diverse patient populations [ 8 , 9 ]. The unique characteristics of the Japanese healthcare system, including its demographic composition and clinical practice patterns, make it particularly important to understand how well current regulatory documentation serves the needs of Japanese healthcare providers [ 10 ]. Furthermore, the implementation of AI in radiology intersects with Japan’s evolving framework for medical data governance, including the Next Generation Medical Infrastructure Act and the Personal Information Protection Act [ 10 ]. These regulations create both opportunities and challenges for the development and validation of AI systems, requiring specialized expertise to navigate the complex landscape of data privacy, clinical validation, and regulatory compliance. The objective of this study is to systematically evaluate the transparency and completeness of clinical evidence provided in package inserts for PMDA-approved AI-based radiology SaMD products. By analyzing the availability of demographic data, performance metrics, and study design information, we aim to identify gaps that may impact clinical implementation and to provide recommendations for enhancing regulatory transparency in this rapidly evolving field. Materials and Methods Data Source and Search Strategy On 31 May 2025 we downloaded the Excel spreadsheet listing all PMDA-approved SaMD products from the PMDA website [ 11 ]. We filtered the data to include only records approved on or before 31 December 2024. Two investigators independently applied these filters, then compared outputs and confirmed complete concordance. Inclusion and Exclusion Criteria Products were included in the analysis if they met the following criteria: (1) approved by PMDA as SaMD, (2) explicitly described as utilizing artificial intelligence, and (3) indicated for use in radiology applications, including but not limited to X-ray, computed tomography (CT), magnetic resonance imaging (MRI), and ultrasound imaging. Products were excluded if they were (1) non-AI software; (2) applications dedicated to endoscopy or laparoscopy; (3) software intended for pathology, other specimen-based laboratory testing, or electrocardiography—applications not directly related to radiology; or (4) consumer-oriented wearable products such as Apple Watch applications. This exclusion criteria ensured focus on traditional radiology imaging modalities. Data Extraction Framework The extraction framework encompassed the following categories: Product characteristics included approval ID, version number, product name and overview, imaging modality, marketing authorization holder, manufacturer, and study design used for regulatory approval. For each product, we documented whether approval was based on standalone performance testing, physician-assisted studies, or both. Clinical study characteristics were extracted in detail, including total sample size, number of positive cases, patient demographic information (nationality, ethnicity, race, sex, age distribution), imaging equipment vendors, and participating clinical sites. We specifically noted whether demographic breakdowns were provided and whether performance metrics were stratified by these characteristics. Performance metrics extraction focused on standard diagnostic accuracy measures including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the receiver operating characteristic curve (AUC), and false positive rates. For physician-assisted studies, we additionally extracted information about reader characteristics, including number of readers, specialization, experience levels, and geographic distribution. Data Analysis Descriptive statistics were used to quantify reporting completeness. For every product we recorded the presence (coded 1) or absence (coded 0) of the following transparency items: total case number; demographic breakdowns for nationality/ethnicity/race, sex, and age; vendor-specific information; site-specific information; and performance metrics stratified by any demographic or technical variable. We then tabulated the number and percentage of products that reported each item; no composite score was calculated and products were not ranked. Performance metrics were summarized using ranges and medians where appropriate. For products reporting multiple performance values (e.g., at different thresholds or for different findings), we documented the manufacturer-designated primary metric. Physician-assisted studies were analyzed separately to assess the impact of AI assistance on diagnostic performance. Results Product Landscape and Eligibility The PMDA data listed 151 SaMD approvals. Of these, 111 products were non-AI and excluded (exclusion criteria 1). Among the remaining 40 AI-enabled products, 15 were endoscopy/laparoscopy applications (exclusion criteria 2), two were pathology/laboratory/electrocardiography applications (exclusion criteria 3), and three were consumer-oriented wearable apps (exclusion criteria 4). Consequently, 20 AI-based radiology products met all eligibility criteria and were included in the analysis ( Figure 1 ). Twelve products had undergone at least one package-insert revision, and our analysis evaluated the latest version available as of June 2025. Download figure Open in new tab Figure 1: Eligibility The flowchart illustrates the systematic screening process for identifying eligible AI-SaMDs in radiology. Starting from all SaMDs approved by the PMDA, products were excluded based on pre-defined criteria, resulting in the final cohort for analysis. SaMD, Software as a Medical Device; PMDA, Pharmaceuticals and Medical Devices Agency; AI, Artificial Intelligence. Table 1 shows a summary of each product. The 20 included radiology AI products demonstrated diverse applications across imaging modalities: CT imaging dominated with eight products [ 12 – 19 ] (40.0%); computed radiography (CR) accounted for seven products [ 20 – 26 ] (35.0%); ultrasound (US) for three products [ 27 – 29 ] (15.0%); MRI for one product [ 30 ] (5.0%); and one product (5.0%) had no imaging modality specified [ 31 ]. Five products (25.0%) were specifically developed for COVID-19-related imaging findings [ 13 – 17 ]. View this table: View inline View popup Download powerpoint Table 1: Product characteristics Transparency in Clinical Setting Reporting Analysis of data availability revealed significant gaps in the reporting of clinical study characteristics ( Figure 2 ) ( Table 2 ). In standalone performance studies, none of the products (20/20, 100%) provided complete demographic information—including nationality/ethnicity/race, sex, and age. Most products (16/20, 80%) reported only the number of cases without any demographic breakdown. View this table: View inline View popup Download powerpoint Table 2: Stand-alone performance study Download figure Open in new tab Figure 2: Data availability within each product Availability of demographic and performance data for the 20 included products. The bar charts show the number of products with data publicly available in regulatory documents (blue) or not reported (red). Data availability is shown separately for (A) Stand-alone performance studies and (B) Physician-assisted studies. Categories assessed include Case demographics, Reader demographics, and Performance results stratified by various factors. Physician-assisted studies showed similarly limited transparency in reader characteristics ( Figure 2 ) ( Table 3 ). Among the 12 products that included physician-assisted validation, most studies (11/12, 92%) detailed reader experience levels, but only one (1/12, 8%) reported reader nationality or practice location. View this table: View inline View popup Download powerpoint Table 3: Physician-assisted study Clinical Performance Metrics Standalone performance studies demonstrated wide variability in reported metrics ( Table 2 ). Differences in experimental design, reported outcomes, and chosen evaluation metrics meant that comparability across products was not necessarily high. Sensitivity values ranged from 55.0% to 100%, with COVID-19 detection applications generally showing variable performance depending on confidence thresholds. Specificity showed even greater variability, ranging from 2.2% to 97.6%, with several products reporting specificity below 50%. Physician-assisted studies consistently demonstrated performance improvements with AI assistance ( Table 3 ). Twelve products reporting physician-assisted validation showed statistically significant improvements in primary performance metrics. The magnitude of improvement varied considerably across studies. Notably, less experienced readers showed greater performance gains, with one study reporting AUC improvement from 0.6470 to 0.6972 for junior neurosurgeons compared to 0.7990 to 0.8218 for experienced radiologists [ 30 ]. Subgroup Performance Analysis Critical gaps were identified in subgroup performance reporting. No products provided performance metrics stratified by patient age, sex, or ethnicity, despite the known impact of demographic factors on AI performance. Only 3 products (15.0%) reported vendor-specific performance differences, revealing substantial variations. For example, one lung nodule detection system showed sensitivity ranging from 65% on GE equipment to 69% on Canon systems, with false positive rates varying from 1.3 to 2.0 per patient across vendors. Site-specific performance data was absent from all package inserts, preventing assessment of generalization across different clinical settings. Discussion This scoping review reveals fundamental gaps in the transparency of clinical evidence for PMDA-approved AI-based radiology software, with significant implications for clinical implementation and patient safety. The finding that none of the products provide complete demographic information and none offer subgroup-stratified performance metrics represents a critical barrier to evidence-based adoption of these technologies in Japanese healthcare settings. Implications for Clinical Implementation The wide variability in performance metrics underscores the importance of understanding the specific clinical context and validation conditions for each AI system [ 4 ]. Without detailed demographic information or site-specific performance data, clinicians cannot adequately assess whether published performance metrics will translate to their specific patient populations. This uncertainty may lead to either inappropriate rejection of beneficial technologies or, conversely, over-reliance on systems that may not perform as expected in local contexts [ 9 ]. Of the twenty AI-based radiology products, twelve included physician-assisted studies. The consistent performance improvements demonstrated in physician-assisted studies suggest that AI integration can enhance diagnostic accuracy across experience levels. However, the greater gains observed among less experienced readers raise important questions about training requirements and the potential for AI to either reduce or exacerbate expertise-related disparities in diagnostic performance [ 32 ]. No physician-assisted study reported performance results other than by-reader analyses, a notable omission given the heterogeneity of patient populations, imaging protocols, and clinical workflows across Japanese healthcare institutions. The five COVID-19 detection applications warrant separate analysis given their rapid development and deployment timeline, reflecting the pandemic’s influence on AI development priorities. All of these products were approved based solely on standalone performance studies without reader studies. Consequently, each product received conditional approval requiring that appropriate post-marketing studies be conducted to evaluate the product’s performance and clinical utility. These products showed variable performance metrics, with sensitivity ranging from 55.0% to 89.6% (depending on confidence thresholds) and specificity from 37.1% to 90.7%. None provided information about variant-specific performance or temporal validation despite the evolving nature of COVID-19 imaging findings. Regulatory Evolution and International Comparisons Japan’s PMDA has been progressive in establishing approval pathways for AI-based medical devices, yet our findings suggest that documentation requirements have not evolved to match the unique characteristics of AI systems [ 33 ]. International regulatory bodies, including the Food and Drug Administration and European authorities, have begun implementing more stringent requirements for AI transparency, including mandatory reporting of training data characteristics and performance across demographic subgroups [ 5 ]. The absence of such requirements in current PMDA package inserts places Japanese healthcare providers at a disadvantage in making informed implementation decisions. The contrast between Japan’s advanced regulatory framework for AI approval and the limited transparency requirements for clinical evidence creates a paradox. While the PMDA’s efficiency in approving AI products has positioned Japan in the top tier of medical AI adoption, the lack of detailed performance information may ultimately hinder successful clinical integration and potentially compromise patient safety [ 3 ]. The Role of Real-world Performance Monitoring The gaps identified in pre-market clinical evidence underscore the critical importance of post-market surveillance and real-world performance monitoring for AI-based medical devices. Unlike traditional medical devices, AI systems can exhibit performance drift over time due to changes in patient populations, imaging protocols, or clinical practices [ 34 ]. Current package insert requirements do not address this dynamic nature of AI performance, nor do they provide frameworks for ongoing validation. This situation creates opportunities for specialized organizations that can bridge the gap between regulatory compliance and clinical implementation needs. Companies with expertise in Japan’s Next Generation Medical Infrastructure Act and Personal Information Protection Act are uniquely positioned to facilitate privacy-preserving, multi-institutional validation studies that can provide the real-world evidence lacking in current regulatory documentation. Such organizations can establish standardized frameworks for continuous performance monitoring, ensuring that AI systems maintain their expected performance across diverse clinical settings while complying with Japan’s strict data privacy regulations. Recommendations for Enhanced Transparency Based on our findings, we propose several recommendations for enhancing transparency in AI-based radiology software documentation. First, package inserts should include mandatory reporting of demographic characteristics for both training and validation datasets, with performance metrics stratified by key demographic variables. Second, vendor-specific and site-specific performance data should be required when technically feasible, acknowledging the impact of imaging equipment and clinical workflows on AI performance. Third, for physician-assisted studies, detailed reader characteristics including specialization, experience levels, and geographic distribution should be standard requirements. This information is essential for healthcare institutions to assess the training and implementation requirements for their specific workforce. Fourth, products should include clear statements about the reference standards used for validation, particularly important for conditions like COVID-19 where diagnostic criteria have evolved over time. Industry Innovation and Future Directions The current regulatory landscape creates both challenges and opportunities for innovation in medical AI validation and implementation. Organizations specializing in medical data governance and AI validation can play a crucial role in establishing industry standards that exceed minimum regulatory requirements. By leveraging frameworks such as the Next Generation Medical Infrastructure Act, these organizations can create secure, privacy-preserving environments for continuous AI validation across multiple institutions. Furthermore, the development of standardized reporting templates and performance monitoring dashboards could significantly enhance transparency while reducing the burden on individual manufacturers. Industry-led initiatives for voluntary transparency standards, potentially coordinated through professional societies or industry associations, could accelerate the evolution of regulatory requirements while immediately benefiting clinical users. Limitations First, our analysis was limited to publicly available package inserts; additional information accessible through manufacturer communications or training materials could not be captured. Second, we lacked access to the raw clinical-study data underlying package-insert claims, preventing independent verification of performance metrics and deeper assessment of study quality. Third, this review focused exclusively on PMDA-approved products; third-party–certified AI-SaMD, which are more numerous in Japan, were not evaluated and may display different transparency patterns. Conclusion This scoping review of PMDA-approved AI-based radiology software reveals significant gaps in the transparency and completeness of clinical evidence available to healthcare providers. The absence of demographic stratification, vendor-specific performance data, and detailed validation conditions creates uncertainty for clinicians and healthcare institutions seeking to adopt these technologies. Addressing these gaps requires coordinated efforts from regulators, manufacturers, and specialized organizations with expertise in medical data governance and AI validation. Enhanced transparency standards, coupled with robust frameworks for continuous real-world performance monitoring, are essential to unlock the full potential of AI in Japanese radiology practice while safeguarding clinical effectiveness and patient safety. Data Availability All data used in this study are publicly available regulatory documents provided by the Pharmaceuticals and Medical Devices Agency (PMDA), Japan. No additional datasets were generated or analyzed. Footnotes Competing interests T. Kikuchi, H. Hyakutake, S. Kawabe, and D. Ueda serves as directors of Medical AI Promotion Institute Co., Ltd. R. Ito is affiliated with the Department of Innovative Biomedical Visualization, Nagoya University Graduate School of Medicine, which is supported by Canon Medical Systems Corporation as an industry–academia collaborative research course. Funding information This work was supported by JST PRESTO, Japan, Grant Number JPMJPR2521. References 1. ↵ Topol EJ . High-performance medicine: the convergence of human and artificial intelligence . Nat Med . 2019 ; 25 : 44 – 56 . OpenUrl CrossRef PubMed 2. ↵ Report on AI-based Software as a Medical Device (SaMD) [Internet] . Pharmaceuticals and Medical Devices Agency . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/files/000266100.pdf 3. ↵ PMDA Updates: 2025 Spring [Internet] . Pharmaceuticals and Medical Devices Agency . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/files/000275910.pdf 4. ↵ Yang Y , Zhang H , Gichoya JW , Katabi D , Ghassemi M. The limits of fair medical imaging AI in real-world generalization . Nat Med . 2024 ; 30 : 2838 – 48 . OpenUrl PubMed 5. ↵ Transparency for Machine Learning-Enabled Medical Devices: Guiding Principles [Internet] . U.S. Food and Drug Administration. FDA ; 2024 [cited 2025 Jul 9 ]. Available from: https://www.fda.gov/medical-devices/software-medical-device-samd/transparency-machine-learning-enabled-medical-devices-guiding-principles 6. ↵ Regulations and Approval/Certification of Medical Devices [Internet] . Pharmaceuticals and Medical Devices Agency . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/english/review-services/reviews/0004.html 7. ↵ pmda . 医 療 機 器 の 添 付 ⽂ 書 の 記 載 要 領(細 則) [Internet] . Available from: https://www.mhlw.go.jp/content/11120000/000966918.pdf 8. ↵ Shick AA , Webber CM , Kiarashi N , Weinberg JP , Deoras A , Petrick N , et al. Transparency of artificial intelligence/machine learning-enabled medical devices . NPJ Digit Med . 2024 ; 7 : 21 . OpenUrl PubMed 9. ↵ Lawrence R , Dodsworth E , Massou E , Sherlaw-Johnson C , Ramsay AIG , Walton H , et al. Artificial intelligence for diagnostics in radiology practice: a rapid systematic scoping review . EClinicalMedicine . 2025 ; 83 : 103228 . OpenUrl PubMed 10. ↵ Roadmap for the Promotion of Healthcare DX (Digital-Transformation) [Internet] . Ministory of Health, Labour and Walfare . [cited 2025 Jul 9 ]. Available from: https://www.mhlw.go.jp/english/policy/health-medical/healthcare-dx/dl/Roadmap-for-the-Promotion-of-Healthcare-DX(Digital-Transformation).pdf 11. ↵ ププ ログラム ログラム [Internet] . 独⽴⾏政法⼈ 医薬品医療機器総合機構 . [cited 2025 Jul 20 ]. Available from: https://www.pmda.go.jp/review-services/drug-reviews/about-reviews/devices/0052.html 12. ↵ AI-Rad コンパニオン [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.info.pmda.go.jp/downfiles/md/PDF/340102/340102_30200BZX00202000_A_01_02.pdf 13. ↵ COVID-19肺炎画像解析AI プログラム InferRead CT Pneumonia [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.info.pmda.go.jp/ygo/pack/459512/30200BZX00184000_1_01_02/ 14. COVID-19 肺炎画像解析 プログラム FS-AI693 型 [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/671001_30300BZX00145000_A_01_02 15. COVID-19 肺炎画像解析プログラム Ali-M3 [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.info.pmda.go.jp/downfiles/md/PDF/130528/130528_30200BZX00212000_A_01_01.pdf 16. COVID-19 肺炎画像解析プログラム SCO-PA01 [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.info.pmda.go.jp/downfiles/md/PDF/480122/480122_30400BZX00123000_A_01_01.pdf 17. ↵ HOPE LifeMark-CAD 肺炎画像解析⽀援プログラム for COVID-19 [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/672251_30300BZX00350000_A_01_05 18. 肺 結節検出プログラム FS-AI688 型 [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/671001_30200BZX00150000_A_01_10 19. ↵ 肋 ⾻⾻折検出プログラム FS-AI691 型 [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/671001_30300BZX00244000_A_01_10 20. ↵ PanoSCOPE(パノスコープ) [Internet] . [cited 2025 Jul 9 ]. Available from: https://panoscope.media-inc.co.jp/pdf/Package-Inserts.pdf 21. 医 ⽤画像解析ソフトウェア EIRL Chest XR [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/171955_30400BZX00285000_A_00_04 22. 医 ⽤画像解析ソフトウェア EIRL X-ray Lung nodule [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/171955_30200BZX00269000_C_00_02 23. 画 ⽤画像解析ソフトウェア KDSS-CXR-AI-101 [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/290447_30300BZX00271000_A_01_05 24. 胸 部 X 線画像病変検出(CAD)プログラムLU-AI689 ? [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/671001_30300BZX00188000_A_01_11 25. 胸 部 X 線肺炎検出エンジン DoctorNet JLK-CRP [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.info.pmda.go.jp/downfiles/md/PDF/201752/201752_30300BZX00339000_A_01_01.pdf 26. ↵ 線 維化を伴う間質性肺疾患検出⽀援プログラム BMAX [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/270505_30500BZX00262000_A_01_01 27. ↵ HOPE LifeMark 胎児⼼臓超⾳波スクリーニング⽀援システム [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.info.pmda.go.jp/downfiles/md/PDF/672251/672251_30600BZX00155000_A_01_01.pdf 28. 乳 がん診断⽀援プログラム RN-デカルト [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.info.pmda.go.jp/downfiles/md/PDF/459512/459512_30200BZX00379000_1_01_01.pdf 29. ↵ 乳 癌超⾳波画像診断⽀援ソフトウェア スマートオピニオン METIS Eye [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.smaopi.com/wp-content/uploads/2025/03/0f8507b3a70648a285498c7dcd8d3965.pdf 30. ↵ 医 ⽤画像解析ソフトウェア EIRL aneurysm [Internet] . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/PmdaSearch/kikiDetail/ResultDataSetPDF/171955_30100BZX00142000_A_01_07 31. ↵ 類 似画像症例検索ソフトウェアFS-CM687 型 [Internet] . [cited 2025 Jul 9 ]. Available from: https://qx-files.yaozh.com/rbsms/671001_30100BZX00263000_A_01_04.pdf 32. ↵ Lee SE , Kim HJ , Jung HK , Jung JH , Jeon J-H , Lee JH , et al. Improving the diagnostic performance of inexperienced readers for thyroid nodules through digital self-learning and artificial intelligence assistance . Front Endocrinol (Lausanne) . 2024 ; 15 : 1372397 . OpenUrl PubMed 33. ↵ Subcommittee on Software as a Medical Device Utilizing AI and Machine Learning [Internet] . Pharmaceuticals and Medical Devices Agency . [cited 2025 Jul 9 ]. Available from: https://www.pmda.go.jp/english/rs-sb-std/sb/subcommittees/0023.html 34. ↵ Kore A , Abbasi Bavil E , Subasri V , Abdalla M , Fine B , Dolatabadi E , et al. Empirical data drift detection experiments on real-world medical imaging data . Nat Commun . 2024 ; 15 : 1887 . OpenUrl CrossRef PubMed View the discussion thread. Back to top Previous Next Posted October 03, 2025. Download PDF Data/Code Email Thank you for your interest in spreading the word about medRxiv. NOTE: Your email address is requested solely to identify you as the sender of this article. Your Email * Your Name * Send To * Enter multiple addresses on separate lines or separate them with commas. You are going to email the following Scoping Review of Regulatory Transparency in AI-based Radiology Software: Analysis of PMDA-approved SaMD Products Message Subject (Your Name) has forwarded a page to you from medRxiv Message Body (Your Name) thought you would like to see this page from the medRxiv website. Your Personal Message CAPTCHA This question is for testing whether or not you are a human visitor and to prevent automated spam submissions. Share Scoping Review of Regulatory Transparency in AI-based Radiology Software: Analysis of PMDA-approved SaMD Products Tomohiro Kikuchi , Shannon L Walston , Hirotaka Takita , Yasuhito Mitsuyama , Rintaro Ito , Masahiro Hashimoto , Takeshi Nakaura , Hiroaki Hyakutake , Sho Kawabe , Harushi Mori , Daiju Ueda medRxiv 2025.10.02.25336333; doi: https://doi.org/10.1101/2025.10.02.25336333 Share This Article: Copy Citation Tools Scoping Review of Regulatory Transparency in AI-based Radiology Software: Analysis of PMDA-approved SaMD Products Tomohiro Kikuchi , Shannon L Walston , Hirotaka Takita , Yasuhito Mitsuyama , Rintaro Ito , Masahiro Hashimoto , Takeshi Nakaura , Hiroaki Hyakutake , Sho Kawabe , Harushi Mori , Daiju Ueda medRxiv 2025.10.02.25336333; doi: https://doi.org/10.1101/2025.10.02.25336333 Citation Manager Formats BibTeX Bookends EasyBib EndNote (tagged) EndNote 8 (xml) Medlars Mendeley Papers RefWorks Tagged Ref Manager RIS Zotero Tweet Widget Facebook Like Google Plus One Subject Area Radiology and Imaging Subject Areas All Articles Addiction Medicine (568) Allergy and Immunology (863) Anesthesia (299) Cardiovascular Medicine (4425) Dentistry and Oral Medicine (443) Dermatology (382) Emergency Medicine (607) Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1507) Epidemiology (15222) Forensic Medicine (30) Gastroenterology (1123) Genetic and Genomic Medicine (6589) Geriatric Medicine (667) Health Economics (997) Health Informatics (4524) Health Policy (1368) Health Systems and Quality Improvement (1612) Hematology (540) HIV/AIDS (1264) Infectious Diseases (except HIV/AIDS) (15910) Intensive Care and Critical Care Medicine (1103) Medical Education (623) Medical Ethics (145) Nephrology (667) Neurology (6588) Nursing (346) Nutrition (998) Obstetrics and Gynecology (1143) Occupational and Environmental Health (956) Oncology (3331) Ophthalmology (971) Orthopedics (369) Otolaryngology (420) Pain Medicine (435) Palliative Medicine (129) Pathology (663) Pediatrics (1690) Pharmacology and Therapeutics (691) Primary Care Research (710) Psychiatry and Clinical Psychology (5440) Public and Global Health (9221) Radiology and Imaging (2195) Rehabilitation Medicine and Physical Therapy (1369) Respiratory Medicine (1196) Rheumatology (593) Sexual and Reproductive Health (710) Sports Medicine (529) Surgery (710) Toxicology (99) Transplantation (289) Urology (265) (function(){function c(){var b=a.contentDocument||a.contentWindow.document;if(b){var d=b.createElement('script');d.innerHTML="window.__CF$cv$params={r:'9ffe64124bf706eb',t:'MTc3OTQ3OTg1Nw=='};var a=document.createElement('script');a.src='/cdn-cgi/challenge-platform/scripts/jsd/main.js';document.getElementsByTagName('head')[0].appendChild(a);";b.getElementsByTagName('head')[0].appendChild(d)}}if(document.body){var a=document.createElement('iframe');a.height=1;a.width=1;a.style.position='absolute';a.style.top=0;a.style.left=0;a.style.border='none';a.style.visibility='hidden';document.body.appendChild(a);if('loading'!==document.readyState)c();else if(window.addEventListener)document.addEventListener('DOMContentLoaded',c);else{var e=document.onreadystatechange||function(){};document.onreadystatechange=function(b){e(b);'loading'!==document.readyState&&(document.onreadystatechange=e,c())}}}})();

Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.

My notes (saved in your browser only)

Ask this paper AI returns verbatim quotes from the full text · source: preprint-html

Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. This is a recent paper (2025) — citers typically take a year or two to land, and the OpenAlex reference graph may still be filling in.

Source provenance

europepmc
last seen: 2026-05-20T01:45:00.602351+00:00
unpaywall
last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-4.0