Abstract
Objective Pulsed field ablation (PFA) relies on irreversible electroporation to create nonthermal cardiac lesions, yet real-time indicators of electroporation progression and validated lethal electric field thresholds remain limited. This study aimed to develop a bioimpedance-based metric for real-time monitoring of cardiac electroporation, evaluate the impact of myocardial anisotropy under electroporation conditions, and derive waveform-specific lethal electric field thresholds.
Introduction
Current PFA procedures lack direct intraoperative feedback on lesion formation, and uncertainty remains regarding the role of myocardial fiber orientation in shaping electric field distributions. Because electroporation dynamically alters tissue electrical properties, monitoring these changes during treatment may improve prediction of ablation outcomes.
Methods
PFA was delivered to fresh ex vivo porcine ventricular tissue using clinically relevant and energy-matched waveforms with pulse widths from 1 to 100 µs. Inter-burst broadband electrical impedance spectroscopy was performed using a low-voltage diagnostic waveform to quantify burst-resolved impedance changes. Lesions were visualized using metabolic staining, then finite element models incorporating nonlinear electroporation-dependent conductivity were used to compare anisotropic and homogenized electric field distributions. Lethal electric field thresholds were estimated by fitting simulated contours to measured lesion areas and validated using uniform electric fields generated by a parallel electrode array.
Results
Across all waveforms, impedance measurements showed a rapid initial decrease followed by stabilization, indicating early electroporation saturation. Burst-to-burst percent change in impedance slope provided a consistent, waveform-agnostic metric of electroporation progression. Lesion morphology was not systematically influenced by fiber orientation, and modeling demonstrated that electroporation-induced conductivity increases homogenized tissue anisotropy. Lethal electric field thresholds increased with decreasing pulse width, ranging from 517 ± 46 V/cm (100 µs) to 1405 ± 55 V/cm (1 µs), and were validated under uniform field conditions.
Conclusion
Bioimpedance-assisted monitoring enables real-time assessment of cardiac electroporation, while electroporation-induced homogenization supports simplified modeling and standardized PFA treatment design.
Competing Interest Statement
The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: The authors have patents related to the paper. R.V.D. receives royalty income from technologies he has invented. S.D. is the Chief Technology Officer (CTO) of Contour Medical.
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)