Keywords
Epilepsy surgery; seizure matching system; seizure onset region; interrater
agreement; precision medicine; stereo-electroencephalography
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
3
Abstract
Background and Objectives: The proportion of patients becoming seizure-free after
epilepsy surgery has stagnated. Large multi-center stereo-electroencephalography datasets
can potentially allow comparing a new patient to past similar cases and make clinical
decisions with the knowledge of how similar cases were treated in the past. However, the
complexity of these evaluations makes the manual search for similar patients in a large
database impractical. We aim to develop an automated system that electrographically and
anatomically matches seizures from a patient to those in a database. In addition, since we do
not know what features define seizure similarity, particularly considering the various stereo-
electroencephalography implantation schemes, we evaluate the agreement and features
among experts in classifying seizure similarity.
Methods
We utilized SEEG seizures from consecutive patients who underwent stereo-
electroencephalography for epilepsy surgery. Eight international experts evaluated seizure-
pair similarity using a four-level similarity score through a graphical user interface. As our
primary outcome, we developed and validated an automated seizure matching system by
employing a leave-one-expert-out approach. Secondary outcomes included the inter-rater
agreement and features for classifying seizure similarity.
Results
320 SEEG seizures from 95 patients were utilized. The seizure matching system
achieved an area-under-the-curve of 0.82 (95% CI, 0.819-0.822), indicating its feasibility. Six
distinct seizure similarity features were identified and proved effective: onset region, onset
pattern, propagation region, duration, extent of spread, and propagation speed. Among these
features, the onset region showed the strongest correlation with expert scores (Spearman’s
rho=0.75, p<0.001). Additionally, the moderate inter-rater agreement confirmed the
practicality of our approach: for the four-level classification, median agreement was 73.9%
(interquartile range, 7%), and beyond-chance Gwet’s kappa was 0.45 (0.16); for the binary
classification of similar vs. not related, agreement stood at 71.9% (4.7%) with a kappa of 0.46
(0.13).
Discussion
We demonstrate the feasibility and validity of a stereo-electroencephalography
seizure matching system across patients, effectively mirroring the expertise of epileptologists.
This novel system can identify patients with seizures similar to that of a patient being
evaluated, thus optimizing the treatment plan by considering the treatment and the results of
treating similar patients in the past, potentially resulting in an improved surgery outcome.
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
4
Introduction
Epilepsy is a prevalent neurological disorder affecting approximately 70 million people
worldwide.1 About 40% of patients have drug-resistant epilepsy, i.e., they do not respond to
anti-seizure medications.2 The main potential cure for these patients is surgery. Stereo-EEG
(SEEG) has gained acceptance around the world, 3 as precise localization of the epileptic
focus at the sublobar-level is necessary to achieve seizure freedom with minimal functional
deficits. Despite these advances, the success rate of epilepsy surgery has been suboptimal 2
and has stagnated over the past decades. The number of SEEG patients at each center is
limited by the complexity of the procedure and there is significant variability in
characteristics and implantation strategies across patients. 4–6 Consequently, most epilepsy
centers do not have enough patient cases for epileptologists to optimize the surgery for new
patients by comparing with past patients having similar characteristics. Almost every patient
presents a novel challenge.
An unexplored avenue for bridging this gap is developing an automated system that can
retrieve past patient cases that closely resemble a new incoming patient. Given the
individualized nature of epilepsy surgery, such a system could be beneficial for optimizing
treatment options. This is particularly important as epilepsy surgery is a form of precision
medicine that is individually tailored to each patient. Large open SEEG datasets are now
available
7–9 and others with several thousand patients could be developed in the future. An
automated system may have the potential to aid epileptologists to review large SEEG
databases rapidly, learn from past patients, and optimize treatment plans of new patients, 10
something that is impractical to do manually. The identification of electrographically and
anatomically similar seizures is the first step towards matching patients. However, what
makes experts consider SEEG seizures similar is not clear, particularly in the context of
different electrode positions. Hence, developing an automated seizure matching system
requires a quantitative study of expert inter-rater agreement (IRA) regarding seizure
similarity and the definition of which features are relevant for experts in assessing seizure
similarity. Several studies report that the inter-rater agreement for epileptic EEG patterns
such as interictal epileptiform discharges,
11 ictal-interictal-continuum,12 neonatal seizures, 13
and intracranial EEG high frequency oscillations, 14 may be low to moderate. However,
similar studies on pre-surgical planning in epilepsy surgery remain limited.15–17
We assessed the expert IRA in determining if SEEG seizures gathered from different patients
are indeed similar and which features contributed to this similarity. Based on evidence from
scalp EEG,
11,12 we hypothesized that there exists a moderate agreement for seizure similarity
across epileptologists and that a generalizable automated seizure matching system can
therefore be developed. First, we measured the IRA across experts in considering two
seizures similar by providing information such as the SEEG seizure signals, implantation
scheme, and the anatomical regions corresponding to the implanted electrodes, similar to a
typical clinical setting. Second, using the similarity scores provided by the experts, we
investigated the features considered relevant in matching seizures. Finally, utilizing these
features, we propose a reliable automated seizure matching system for improving pre-surgical
planning in epilepsy.
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
5
Materials and methods
Study Design and Patient Selection
Ninety-five consecutive patients who underwent SEEG with imaging at the Montreal
Neurological Institute and Hospital (MNI) between 2009-2019 were analyzed
(Supplementary Table 1). If a patient had multiple surgeries, we considered the SEEG before
the last surgery. We considered all the patients with complete neuroimaging datasets who had
at least one artifact-free electroclinical seizure recorded after 48 hours post-implantation. The
recordings were acquired with either Harmonie (Stellate) or Nihon-Kohden amplifiers, using
homemade MNI or commercial DIXI electrodes. 18 This study was approved by the MNI
Ethics Board (IRB 2019-4880). Written informed consent was obtained from all patients. Our
primary objective was to develop an automated system for matching seizures. However, as
we do not know what features define seizure similarity, particularly considering the various
stereo-electroencephalography implantation schemes, we also included the crucial step to
evaluate the agreement among experts in classifying seizure similarity. We conducted the
interrater agreement study following the Standards for Reporting Diagnostic Accuracy
(STARD) guidelines.
19 The independent seizure similarity marking by experts who had at
least one year of SEEG training for epilepsy surgery serves as index test. The reference
standard is the consensus (majority agreement) in seizure similarity among these experts. The
study was conducted in three phases (Figure 1A).
Phase 1: Seizure characterization
A total of 320 electro-clinical seizures were extracted. To avoid overrepresentation of any
patient, we selected a maximum of three seizures per seizure-type per patient. The seizure
characteristics were considered independent of vigilance state. 20 For each seizure, the onset,
the end, and the onset pattern 21 were marked on each channel by two board certified
neurophysiologists. When the two experts disagreed, a third neurophysiologist was consulted
to reach a consensus. The onset was marked as the first sustained rhythmic change in SEEG
from the background lasting at least ten seconds independent of the presence of fast
activity.
22 We mapped each SEEG channel into anatomical regions using the 140-region
MICCAI atlas.23,24
To compare pairs of seizures from different patients, we used a graphical user interface (GUI,
Supplementary Figure 1) that integrated multimodal data including implantation scheme,
SEEG signals, and the expert markings mentioned above; the comparison resulted in a four-
level similarity score (very similar, somewhat similar, low similarity, not related). Next,
through a collaborative process involving in-depth discussions with the clinical
epileptologists who marked the SEEG, we identified six clinically relevant features for
determining seizure similarity: onset region(s), propagation region(s), duration, spread,
propagation speed, and onset pattern
21 (Figure 1B). The detailed definitions and
implementation of these features are given in Supplementary S1. An example seizure pair
utilized in this study is illustrated in Figure 2. Lastly, we used the following initial weights
for the features after consulting with the three experts: 0.5 for onset region and 0.1 for each
remaining feature. With these weights ( /g1875 /g3036) for the six feature values ( /g1858 /g3036), we computed the
initial similarities,
/g1871/g3404 ∑ /g1875 /g3036/g3400/g1858 /g3036
/g2874
/g3036/g2880/g2869 (1)
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
6
Phase 2: Preliminary assessment of GUI and features
Two independent experts not involved in phase 1 evaluated the GUI and scoring of seizure
similarity. Each expert assessed 64 pairs of seizures from different patients, randomly
selected according to the initial similarity scores, with 16 (25%) allocated to each similarity-
level. The experts provided the following suggestions regarding the interface: (1) incorporate
two sagittal (left and right) and coronal views of the implantation scheme, along with an axial
view. (2) include anatomical locations corresponding to each SEEG channel. (3) implement
an SEEG segment that allows navigation back and forth for at least 100 seconds, with a
visible time indicator. The GUI was modified according to their suggestions. The feature
weights were adjusted to 0.4 for onset region, 0.2 for propagation region, and 0.1 each for the
remaining features, by correlating the feature values with expert scores (Spearman’s rho), and
the new similarities were computed.
Phase 3: Evaluation of seizure similarity
To ensure the generalizability of the results and mitigate potential bias from similar training
and expertise, we selected eight experts trained at different tertiary epilepsy centers around
the world, who did not participate in phases 1 and 2. Each expert assessed 64 pairs of seizures
each, with 16 (25%) allocated a priori to each similarity-level. Similarity levels were defined
with the weights initially imposed for each feature to ensure a well-balanced distribution of
seizure pairs for the experts (some very similar, some very different...). These weights did not
influence their evaluation of features. The features were not disclosed to the experts apriori,
allowing them the autonomy to assign similarity scores based on their training and expertise.
Thirty-two pairs were identical across the experts. Twenty-two pairs were randomly selected,
and the final ten pairs were flipped pairs randomly chosen from the set of 54 (32+22). Based
on these scores, we investigated the IRA, intra-rater consistency, univariate/multivariate
feature assessment, and developed the seizure matching system. . Further, we conducted a
survey among experts to analyze their opinions on the seizure matching system and the
relevant features for matching (Supplementary S2).
The three analyses, namely, the univariate, multivariate, and survey-based, provided three
distinct pieces of information. The univariate analysis gave us an estimate whether the
selected features were important for seizure similarity. The multivariate results provided
insights into the optimal combination of features for determining similarity, considering
correlations between features. Lastly, survey-based opinions offered an understanding of how
experts perceived the relative importance of the features.
Evaluation and Statistical Analysis
Intra-rater consistency and Inter-rater agreement
We quantified the intra-rater consistency for each expert by calculating the percentage
agreement between the similarity scores of the ten flipped seizure pairs. We applied the
Stuart-Maxwell’s test for marginal homogeneity to examine whether experts categorized
seizure similarity into four-levels with comparable proportions. 25 The p-values were
corrected for multiple comparisons by controlling for the false discovery rate.26
The pairwise IRA was determined based on the 32 identical seizure pair similarity scores, by
calculating the percentage agreement (/g1842 /g3028) and chance adjusted Gwet’s kappa.27,28 Kappa was
calculated as (/g1842 /g3028/g3398/g1842 /g3030/g4667//g46661 /g3398 /g1842 /g3030), where /g1842 /g3030 is the chance agreement. Kappa was computed in
two scenarios: considering the four-level similarity scores, and by combining the scores into
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
7
binary labels: similar (including “very similar” and “somewhat similar”), vs. not related
(including “less similarity” and “not related”). We utilized standard convention for
interpreting of kappa; 0-0.20 (slight), 0.21-0.40 (fair), 0.41-0.60 (moderate), 0.61-0.80
(substantial), and 0.81-1.00 (almost perfect).29
We also compared the predicted probability of an expert assigning a seizure pair as similar
(binary labels) to the group event probability by applying statistical calibration measures.
This shows how well the expert prediction probabilities agree with the group probability.
First, we binned the seizure pairs into five bins (similarity deemed by one expert, similarity
deemed by two or three experts, similarity deemed by four or five experts, similarity deemed
by six or seven experts, and similarity deemed by all eight experts). We opted for five bins to
maintain a reasonable number of data points in each bin, similar to what has been adopted in
the literature 12. Next, each expert’s prediction probability was defined for each bin as the
proportion of seizure pairs in the bin that were marked as similar by the expert. For each
expert, the calibration curve is estimated with the group probabilities on the x-axis and the
expert’s prediction probability on the y-axis. A calibration score per expert was also defined
as the mean absolute value of the difference between an individual’s prediction probabilities
and the group probabilities. Significant overcalling and undercalling were defined as having a
calibration score above 0.2.
12 A calibration score lower than 0.2 indicated that the expert
predictions were in alignment with the group probability.
Seizure matching system and analysis of features
All 64 seizure pairs were considered for univariate/multivariate feature assessment and the
development of the seizure matching system. Here, we transformed the similarity scores into
numerical values using a uniform scale (0, 0.33, 0.66, and 1), representing a spectrum from
‘not related’ to ‘very similar’. In univariate analysis, we investigated how well each feature
correlated with the individual and mean expert scores utilizing Spearman rho. To test that the
correlation values were significant, we determined p-values by generating a distribution of
correlation values by randomly permuting expert scores. The correlations between the six
features were also quantized.
We utilized an ensemble decision tree 30 implementing the seizure matching system. The
parameters of the decision tree are optimized using Bayesian optimization 31. To validate the
model and the features, a leave-one-expert-out (LOEO) cross-validation was employed using
the binary labels. In each step, the seizure pairs marked by one expert were withheld as the
test set. Using the scores from the remaining experts, a model was trained to predict the labels
for the left-out expert. This procedure was repeated for each expert and LOEO validation had
eight runs. The performance of the model was evaluated with the area-under-the-receiver-
operating-characteristics curve (AUC) and area-under-the-precision-recall curve (AUPRC).
To ensure robustness of the results, given that each model training initiates with a random set
of hyperparameters, the LOEO was iterated 100 times (eight runs
/g34001 0 0 ), and the results were
averaged.
The feature importance was determined based on Gini’s diversity index in each step of LOEO
and was averaged. The feature importance was determined based on Gini’s diversity index in
each step of LOEO and was averaged. Decision trees have the capability to identify the most
informative features during the training process. The algorithm evaluates various
combinations of features at each of the decision tree nodes and chooses the combination that
contributes the most to the classification performance, reducing redundancy. Consequently, it
takes care of correlated features automatically. For each expert, we also compared the model
prediction with the four-level similarity scores using Spearman’s rho. Finally, the survey-
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
8
based expert opinions regarding the features were compared with the results of the LOEO
feature importance to identify potential correlations or discrepancies. The evaluation and
analysis was performed using MATLAB 202032 and IRRCAC python toolbox.28
Data Availability
The data that support the findings of this study are available upon reasonable request and if in
accordance with the respective Research Ethics Boards’ policies.
Results
A total of 320 seizures from 95 patients were analyzed in this study. The patient cohort was
diverse: 26 (27.4%) had right, 35 (36.8%) had left, and 34 had bilateral SEEG electrode
implantations; 46 of the 95 patients (48.4%) were female with age=32.5 (17, median
(interquartile range)). Temporal lobe epilepsy was present in 60% (57 patients). Preoperative
magnetic resonance imaging (MRI) revealed mesial temporal sclerosis in seven (7.3%), focal
cortical dysplasia in 20 patients (21.0%), no abnormality in 23 (24.2%), and 45 patients
(47.4%) exhibited tumors, cystic lesions, traumatic lesions, or other abnormalities.
Seizure matching system
We utilized an ensemble decision tree to implement the seizure matching system. It achieved
an AUC of 0.820 (95% CI, 0.819-0.822) and AUPRC=0.723 (95% CI, 0.719-0.727) for the
LOEO validation (across 100 iterations). The AUC was also consistent across experts (range
0.704-0.907, Figure 3). Further, the seizure matching system predictions for each expert were
significantly correlated (each p<0.01) with the four-level similarity scores with rho=0.54
(0.21).
Intra-rater consistency and Interrater agreement
We developed a multimodal GUI to compare similarity across pairs of seizures and modified
it based on phase 2 comments from two experts. Subsequently, we utilized it to evaluate
seizure similarity scores from eight global experts. Utilizing the similarity scores from the
experts, we evaluated the intra-rater consistency and the IRA. The intra-rater consistency was
high at 100% (25%) (median (interquartile range), four-level classification), and 100% (0%),
allowing for a single-level error, for example, categorizing the original pair as ‘low
similarity’ and categorizing the same pair as ‘not related’ when flipped. The IRA was
moderate: four-level classification: agreement=73.9% (7%), beyond-chance agreement
Gwet’s kappa=0.45 (0.16); binary classification of similar vs. not related, agreement=71.9%
(4.7%), kappa=0.46 (0.13); Figure 4A, B. The experts grouped seizure similarity comparably;
the Stuart-Maxwell test achieved non-significant results ( p>0.05) for all combinations of
experts. The mean calibration scores for all experts were 0.11 (0.05), lower than 0.2,
indicating that their marking aligned with the group probability (Figure 4C).
Analysis of features
We determined the feature ranking for seizure similarity using univariate and multivariate
analysis. Out of the six features, only the onset region and the propagation region were
correlated with each other (rho=0.81, p<0.001, Supplementary Figure 3). The onset region
was identified as the most correlated feature with the expert scores: univariate analysis with
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
9
mean expert scores rho=0.75, p<0.001, Figure 5; univariate analysis with individual expert
scores rho=0.52 (0.17), each p<0.05, Figure 6A; multivariate LOEO feature importance=0.79
(0.09), Figure 6B.
Survey results
All eight experts unanimously agreed on the benefits of developing a seizure matching tool.
Additionally, they rated the GUI with a mean score of 8.6/10 for its utility. The onset region
was ranked as the most important and the seizure duration the least important feature by the
experts (Figure 6C, D). Most of the experts (6/8) considered the seizure characteristics
independent of the hemisphere. Four experts were satisfied with the features considered in
this study. Two experts recommended utilizing seizure semiology, and one expert
emphasized the use of the underlying etiology of epilepsy.
Discussion
Despite many advances in SEEG analysis over the past decades, results of surgical outcome
have not clearly improved. One potential reason may be a lack of systems allowing matching
of past patients to patients currently investigated, and benefitting from the experience gained
from the past. In this study, we sought to address the issue by developing a generalizable
automated seizure matching system. Prior to developing an automated system, we had to
determine if there was sufficient agreement among experts when it comes to assessing if two
seizures, from different patients with different implantation schemes, can be considered
similar. The three main findings of this study are: (i) the automated seizure matching system,
evaluated by LOEO cross-validation, yielded an AUC=0.82, demonstrating the feasibility of
developing a reliable clinical system; (ii) there exists a moderate agreement across experts in
determining similarity across SEEG seizures from different patients with different electrode
locations; (ii) the mean expert similarity scores were correlated with six clinically identified
features, with the onset region being the highest ranked feature.
A step towards a reliable patient matching system
In the present investigation, we focused on developing a seizure matching system aimed at
assisting epileptologists in planning epilepsy surgery with the help of the analysis of past
similar patients. The existing literature primarily concentrates on optimizing the pre-surgical
evaluation of epilepsy using methods or biomarkers for identification of the epileptogenic
zone7,33,34 or prognostication of surgery outcomes. 35–38 Given that we have achieved a
moderate IRA (kappa=0.45) and a satisfactory AUC=0.82, we were successful in
demonstrating the feasibility of a seizure matching system. This system can be readily
integrated into current clinical workflows. Its usefulness will increase with the size of the
database available, and it will be optimal with a multicenter database much larger than what
is usually available in one center. For example, when a new patient presents with similar
seizures to that of a database patient, the physician can evaluate the type and extent of
resection that were performed, the outcome, and determine if this can positively impact the
treatment of the current patient. This is a unique approach in a way that it allows the
physician to learn from a large number of prior patient cases.
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
10
High intra-rater consistency and moderate inter-rater agreement
The intra-rater consistency in judging seizure similarity was high, indicating consistent scores
among the experts. Moreover, the experts categorized seizure similarity into four-levels with
a comparable marginal probability. Many studies 11,12 failed to assess intra-rater consistency
prior to evaluating inter-rater agreement. Moderate IRA among experts (kappa=0.45) was
observed in assessing seizure similarity across a sizable, diverse set of patients. This
corroborated with the IRA related to interictal and ictal scalp EEG findings ranging between
0.39-0.48.
11–13 There are two main studies that have investigated agreement across aspects of
pre-surgical planning of epilepsy using invasive EEG: seizure localization (excellent
agreement, intra-class correlation coefficient=0.79, seven centers, number of experts not
reported)
16 and seizure-onset zone identification (substantial, kappa=0.8, two experts). 17
However, both of these studies were performed on a small number of patients (10 and 11)
and almost exclusively with temporal lobe epilepsy. It must also be noted that the task itself,
matching seizures from patients with different implantation schemes, is new to
epileptologists, probably explaining some of the diversity in the approaches taken by the
experts in this study. We did not observe any undercallers or overcallers among the experts
even though they belonged to different institutions and had undergone training in various
centers. These findings underscore the feasibility of a generalizable seizure matching system.
Expert similarity scores correlate with six clinically identified
features
The correlation coefficients were statistically significant and moderate to high for all the six
features in comparison with the mean expert scores. These findings are consistent with the
opinion of epileptologists and suggest that these features hold clinical significance in
determining seizure similarity. In contrast to scalp EEG (routine, sleep, or critical care), for
which standard guidelines have been established, 39,40 intracranial EEG lacks international
guidelines, and a global standard terminology is yet to be devised. With an AUC=0.82, we
were able to satisfactorily quantify the seizure similarity using six features. The seizure onset
region exhibited higher significance than all other features across both univariate and
multivariate analyses, as well as in survey opinion rankings (Figures 5, 6). This finding is
also consistent with the concept of anatomo-electro-clinical correlation, utilized to determine
the epileptogenic zone.
41
Despite aligning with the initial weights assigned based on the opinions of three experts in
phase 1 and two experts in phase 2, the autonomy granted to the eight experts in phase 3,
along with their diverse training backgrounds, ensured that the feature rankings were not
influenced by these initial weights. We currently employed features that appeared to be
commonly used in clinical practice. The same approach can be applied to other features that
may need to be included in the future. Further, we observed that, in their assessment of
feature importance, the experts tended to overestimate the importance of certain features
compared to their actual use of these features when they assessed seizure similarity, such as
the seizure onset pattern and propagation region. While the onset pattern was ranked as the
second-best feature in the survey-based evaluation (Figure 6 C, D), its importance was
comparatively lower in the multivariate feature analysis, when considered alongside the onset
region (Figure 6B). The onset pattern exhibited no correlation with the onset region
(Supplementary Figure 3), suggesting that the onset pattern might not be relevant for patient
matching in combination with the onset region. Similar opinions were observed for the
propagation region; however, it had a high correlation with the onset region (Supplementary
Figure 3).
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
11
Potential avenues for future research and constraints
Seizure similarity serves as the initial step towards achieving patient similarity; it is necessary
to consider other factors such as seizure semiology, 42 MRI findings, 4 etiology, interictal
biomarkers,35 implantation scheme, etc., to have a comprehensive understanding of patient
similarity and facilitate the phenotyping of patients into groups with shared characteristics,
aiding the search for improved personalized treatments. The current study serves a proof-of-
principle that a seizure matching system can be implemented in the current clinical context of
epilepsy surgery. This personalized approach holds promise for enhancing epilepsy surgeries
success rates, leading to improved treatment outcomes and overall patient well-being. This
study represents a critical step towards a patient matching system for epilepsy surgery.
In our analysis, we utilized the Euclidean distance to compute the distance between seizure
onset regions and between propagation regions. It is crucial to acknowledge that connectivity
strength may vary among different brain regions, irrespective of their spatial proximity. We
intend to further explore the potential utilization of functional distances to enhance our
understanding of seizure similarity. Similarly, we acknowledge the existence of variations in
the classification of seizure onset patterns
43. While we have adhered to a specific
classification21, a comparable approach can be applied using alternative classifications.
Conclusions
This study demonstrated the feasibility of an automated system and features for matching
seizures across patients, providing a valuable tool to make use of vast numbers of existing
cases and complement the expertise of epileptologists in SEEG pre-surgical evaluation. The
moderate IRA among experts supports the development of a generalizable automated seizure
matching system. The proposed system achieved promising performance, indicating its
potential to optimize treatment plans and improve surgical outcomes. It can efficiently review
large SEEG databases, aiding in matching similar cases, and facilitating personalized
epilepsy surgery investigation and treatment, something that is impractical to achieve
manually. Prospective evaluation and collaboration are needed to refine and enhance the
system’s capabilities, paving the way for advancements in epilepsy research and improved
patient care.
Acknowledgements
We acknowledge the help and support from Dr. Nicolas von Ellenrieder and the staff and
technicians at the EEG Department of the Montreal Neurological Institute and Hospital
(Lorraine Allard, Nicole Drouin, and Chantal Lessard).
Funding
This work was funded by project grants from the Canadian Institutes of Health Research
(PJT-175056 to BF, FDN-143208 to JG, and MFE CIHR-IRSC:0633005463 to JT), and
Tanenbaum Open Science grant (JT, JG, BF). JT was supported by the Jeanne Timmins
Fellowship. BF was supported by a salary award (“Chercheur-boursier clinicien Senior”) of
the Fonds de Recherche du Québec – Santé 2021-2023.
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
12
References
1. Thijs RD, Surges R, O’Brien TJ, Sander JW. Epilepsy in adults. Lancet.
2019;393(10172):689-701. doi:10.1016/S0140-6736(18)32596-0
2. Frauscher B. Localizing the epileptogenic zone. Curr Opin Neurol . 2020;33(2):198-
206. doi:10.1097/WCO.0000000000000790
3. Gavvala J, Zafar M, Sinha SR, Kalamangalam G, Schuele S. Stereotactic EEG
Practices: A Survey of United States Tertiary Referral Epilepsy Centers. J Clin
Neurophysiol. 2022;39(6):474-480. doi:10.1097/WNP.0000000000000794
4. Astner-Rohracher A, Zimmermann G, Avigdor T, et al. Development and Validation
of the 5-SENSE Score to Predict Focality of the Seizure-Onset Zone as Assessed by
Stereoelectroencephalography. JAMA Neurol . 2022;79(1):70-79.
doi:10.1001/jamaneurol.2021.4405
5. Jehi L, Morita-Sherman M, Love TE, et al. Comparative Effectiveness of Stereotactic
Electroencephalography Versus Subdural Grids in Epilepsy Surgery. Ann Neurol .
2021;90(6):927-939. doi:10.1002/ana.26238
6. Cardinale F, Rizzi M, Vignati E, et al. Stereoelectroencephalography: Retrospective
analysis of 742 procedures in a single centre. Brain. 2019;142(9):2688-2704.
doi:10.1093/brain/awz196
7. Li A, Huynh C, Fitzgerald Z, et al. Neural fragility as an EEG marker of the seizure
onset zone. Nat Neurosci. 2021;24(10):1465-1474. doi:10.1038/s41593-021-00901-w
8. Bernabei JM, Li A, Y. Revell A, et al. Quantitative approaches to guide epilepsy
surgery from intracranial EEG. Brain. Published online 2023:1-11.
doi:10.1093/plphys/kiac605
9. Frauscher B, Ellenrieder N Von, Zelmann R, et al. Atlas of the normal intracranial
electroencephalogram/i1: neurophysiological awake activity in different cortical areas.
Published online 2018:1130-1144. doi:10.1093/brain/awy035
10. Casey JA, Schwartz BS, Stewart WF, Adler NE. Using Electronic Health Records for
Population Health Research: A Review of Methods and Applications. Annu Rev Public
Health. 2016;37:61-81. doi:10.1146/annurev-publhealth-032315-021353
11. Jing J, Herlopian A, Karakis I, et al. Interrater Reliability of Experts in Identifying
Interictal Epileptiform Discharges in Electroencephalograms. JAMA Neurol .
2020;77(1):49-57. doi:10.1001/jamaneurol.2019.3531
12. Jing J, Ge W, Struck AF, et al. Interrater Reliability of Expert
Electroencephalographers Identifying Seizures and Rhythmic and Periodic Patterns in
Electroencephalograms. Neurology. Published online
2022:10.1212/WNL.0000000000201670. doi:10.1212/wnl.0000000000201670
13. Dereymaeker A, Ansari AH, Jansen K, et al. Interrater agreement in visual scoring of
neonatal seizures based on majority voting on a web-based system: The Neoguard
EEG database. Clin Neurophysiol . 2017;128(9):1737-1745.
doi:10.1016/j.clinph.2017.06.250
14. Spring AM, Pittman DJ, Aghakhani Y, et al. Interrater reliability of visually evaluated
high frequency oscillations. Clin Neurophysiol. 2017;128(3):433-441.
doi:10.1016/j.clinph.2016.12.017
15. Flanary J, Daly S, Bakker C, et al. Reliability of visual review of intracranial
electroencephalogram in identifying the seizure onset zone: A systematic review and
implications for the accuracy of automated methods. Epilepsia. 2023;64(1):6-16.
doi:10.1111/epi.17446
16. Haut SR, Berg AT, Shinnar S, et al. Interrater reliability among epilepsy centers:
Multicenter study of epilepsy surgery. Epilepsia. 2002;43(11):1396-1401.
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
13
doi:10.1046/j.1528-1157.2002.20902.x
17. Vila-Vidal M, Pérez Enríquez C, Principe A, Rocamora R, Deco G, Tauste Campo A.
Low entropy map of brain oscillatory activity identifies spatially localized events: A
new method for automated epilepsy focus prediction. Neuroimage. 2020;208(July
2019). doi:10.1016/j.neuroimage.2019.116410
18. Frauscher B, von Ellenrieder N, Dubeau F, Gotman J. Scalp spindles are associated
with widespread intracranial activity with unexpectedly low synchrony. Neuroimage.
2015;105:1-12. doi:10.1016/j.neuroimage.2014.10.048
19. Bossuyt PM, Reitsma JB, Bruns DE, et al. STARD 2015: An updated list of essential
items for reporting diagnostic accuracy studies. BMJ. 2015;351(October):1-9.
doi:10.1136/bmj.h5527
20. Hannan S, Thomas J, Jaber K, et al. The differing effects of sleep on ictal and interictal
network dynamics in drug-resistant epilepsy. Ann Neurol . 2023;n/a(n/a).
doi:https://doi.org/10.1002/ana.26796
21. Perucca P. Intracranial electroencephalographic seizure-onset patterns: effect of
underlying pathology. 2014;(iv). doi:10.1093/brain/awt299
22. Spanedda F, Cendes F, Gotman J. Relations between EEG seizure morphology,
interhemispheric spread, and mesial temporal atrophy in bitemporal epilepsy.
Epilepsia. 1997;38(12):1300-1314. doi:10.1111/j.1528-1157.1997.tb00068.x
23. Landman B, Warfield S. MICCAI 2012 workshop on multi-atlas labeling. In: MICCAI
Grand Challenge and Workshop on Multi-Atlas Labeling, CreateSpace Independent
Publishing Platform. ; 2012.
24. Cuello Oderiz C, Von Ellenrieder N, Dubeau F, et al. Association of Cortical
Stimulation-Induced Seizure with Surgical Outcome in Patients with Focal Drug-
Resistant Epilepsy. JAMA Neurol . 2019;76(9):1070-1078.
doi:10.1001/jamaneurol.2019.1464
25. Trujillo-Ortiz A. StuMaxtest. MATLAB Central File Exchange. Accessed April 1,
2023. https://www.mathworks.com/matlabcentral/fileexchange/6367-stumaxtest
26. Benjamini Y, Hochberg Y. Controlling the False Discovery Rate: A Practical and
Powerful Approach to Multiple Testing. J R Stat Soc Ser B . 1995;57(1):289-300.
doi:10.1111/j.2517-6161.1995.tb02031.x
27. Wongpakaran N, Wongpakaran T, Wedding D, Gwet KL. A comparison of Cohen’s
Kappa and Gwet’s AC1 when calculating inter-rater reliability coefficients: A study
conducted with personality disorder samples. BMC Med Res Methodol . 2013;13(1):1-
7. doi:10.1186/1471-2288-13-61
28. Gwet K. Handbook of Inter-Rater Reliability Fourth Edition.; 2014.
29. Landis JR, Koch GG. The Measurement of Observer Agreement for Categorical Data.
Biometrics. 1977;33(1):159. doi:10.2307/2529310
30. Leo B. Random forests - classification description. Accessed February 13, 2022.
https://www.stat.berkeley.edu/~breiman/RandomForests/cc_home.htm
31. Martinez-Cantin R. BayesOpt: A Bayesian optimization library for nonlinear
optimization, experimental design and bandits. J Mach Learn Res. 2015;15:3735-3739.
32. Inc. TM. MATLAB version: 9.13.0 (R2022b). Published online 2022.
https://www.mathworks.com
33. Klimes P, Cimbalnik J, Brazdil M, et al. NREM sleep is the state of vigilance that best
identifies the epileptogenic zone in the interictal electroencephalogram. Epilepsia .
2019;60(12):2404-2415. doi:10.1111/epi.16377
34. Conrad EC, Tomlinson SB, Wong JN, et al. Spatial distribution of interictal spikes
fluctuates over time and localizes seizure onset. Brain . 2020;143(2):554-569.
doi:10.1093/brain/awz386
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
14
35. Thomas J, Kahane P, Abdallah C, et al. A Subpopulation of Spikes Predicts Successful
Epilepsy Surgery Outcome. Ann Neurol. 2023;93(3):522-535. doi:10.1002/ana.26548
36. Tamilia E, Park EH, Percivati S, et al. Surgical resection of ripple onset predicts
outcome in pediatric epilepsy. Ann Neurol . 2018;84(3):331-346.
doi:10.1002/ana.25295
37. Sinha N, Dauwels J, Kaiser M, et al. Predicting neurosurgical outcomes in focal
epilepsy patients using computational modelling. Brain. 2017;140(2):319-332.
doi:10.1093/brain/aww299
38. Azeem A, von Ellenrieder N, Hall J, Dubeau F, Frauscher B, Gotman J. Interictal spike
networks predict surgical outcome in patients with drug-resistant focal epilepsy. Ann
Clin Transl Neurol. 2021;8(6):1212-1223. doi:10.1002/acn3.51337
39. Hirsch LJ, Fong MWK, Leitinger M, et al. American Clinical Neurophysiology
Society’s Standardized Critical Care EEG Terminology: 2021 Version. J Clin
Neurophysiol. 2021;38(1):1-29. doi:10.1097/WNP.0000000000000806
40. Peltola ME, Leitinger M, Halford JJ, et al. Routine and sleep EEG: Minimum
recording standards of the International Federation of Clinical Neurophysiology and
the International League Against Epilepsy. Epilepsia. 2023;64(3):602-618.
doi:10.1111/epi.17448
41. Talairach J, Bancaud J, Szikla G, Bonis A, Geier S, Vedrenne C. New approach to the
neurosurgery of epilepsy. Stereotaxic methodology and therapeutic results. 1.
Introduction
and history. Neurochirurgie. 1974;20 Suppl 1:1-240.
42. Alim-Marvasti A, Romagnoli G, Dahele K, et al. Probabilistic landscape of seizure
semiology localizing values. Brain Commun. 2022;4(3):1-15.
doi:10.1093/braincomms/fcac130
43. Lagarde S, Buzori S, Trebuchon A, et al. The repertoire of seizure onset patterns in
human focal epilepsies: Determinants and prognostic values. Epilepsia. 2019;60(1):85-
95. doi:10.1111/epi.14604
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
15
Figures
Figure 1: Illustration of study pipeline and seizure similarity features (A) Flow diagram
illustrating the study in three phases. Phase 1 involved seizure selection, seizure marking,
graphical user interface (GUI) development, and identification of seizure similarity features.
Phase 2 included GUI and feature evaluation by two independent experts, and Phase 3
encompassed global evaluation of seizure similarity by eight independent experts. (B)
Illustration of the six features utilized in this study on a seizure from patient ID 38 with right
mesiotemporal lobe epilepsy. In this example, the seizure onset includes six contacts (purple
box), while the seizure propagation region includes eight contacts (green box). The seizure
onset region was in the right hippocampus and amygdala (atlas regions) and the seizure
propagation region included the right fusiform gyrus, planum polare, and the inferior
temporal gyrus. Seizure spread is determined as the mean distance covered by the seizure
within a 5-second interval, in this case 14.9 mm; seizure speed is measured as the maximum
distance covered by the seizure within the same 5-second interval (specifically at t5000 ms),
in this case 6.4 mm/s. The seizure duration was 27.2 seconds, and the seizure onset pattern is
classified as low voltage fast activity (LVFA).
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
16
Figure 2: An example of a seizure pair utilized in this study. We illustrate axial and
coronal views of the implantation scheme, a 50 second (>ten second pre-ictal) SEEG seizure
segment, the brain anatomical locations corresponding to the bipolar channels, and the
seizure onset marking on each channel. In the implantation scheme (left), each circle
represents a bipolar channel, an array of circles represents an SEEG electrode, and the red
channels indicate the bipolar channels involved in the seizure at one-second after the earliest
onset of the seizure. In the SEEG seizure segment (right), we illustrate signals filtered
between 0.3-100 Hz. Each red circle indicates the onset of the seizure on the particular
bipolar channel. Seizure A (patient A) had eight left electrodes targeting mesio-temporal,
cingulate, and frontal regions, and seizure B (patient B) had a bilateral implantation with four
left and two right electrodes targeting bilateral mesial temporal structures and the left frontal
region. We employed six clinically relevant features to assess the similarity between seizure
pairs: seizure onset region, propagation region, duration, spread, propagation speed, and onset
pattern. Both seizures exhibited a quasi-similar onset in the left mesial temporal structures. In
seizure A, the onset was observed in the left amygdala, hippocampus, entorhinal cortex, and
parahippocampal gyrus. On the other hand, seizure B showed an onset in the left amygdala,
hippocampus, mesial part of the planum polare, and the posterior hippocampus. Both seizures
showed early propagation to the mesial frontal area (anterior cingulate cortex) and an onset
pattern characterized by spike-wave followed by low voltage fast activity. Seizure A and B
lasted for a similar duration of 86.4 seconds and 103.4 seconds, respectively. The spread was
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
17
consistent at 42.5mm for both seizures, while propagation speeds differed: 66 mm/s for
seizure A and 100.7 mm/s for seizure B. The similarity values ranging between 0 and 1 (with
1 indicating high similarity) for each feature between this seizure pair were as follows: onset
region ( /g1858 /g2869, 0.95), propagation region ( /g1858 /g2870, 0.91), duration ( /g1858 /g2871, 0.84), spread ( /g1858 /g2872, 0.99),
propagation speed ( /g1858 /g2873, 0.65), and onset pattern ( /g1858 /g2874, 1). This seizure pair was marked as
similar by seven experts (‘Very similar’ by five, and ‘Somewhat similar’ by two experts).
Detailed definitions and implementation of these features are given in Supplementary S2.
Figure 3: Leave-one-expert-out results for each expert. Here we illustrate the predictions
in each run of the leave-one-expert-out cross-validation (y-axis) in comparison with the labels
from the left-out expert (x-axis). Each red circle represents the prediction value of similarity
across a pair of seizures. The prediction values ranged from 0 and 1, with a higher value
indicating better similarity between the seizures. The rho and p-values are computed for the
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
18
prediction values vs. the four-level similarity scores. The rho values were statistically
significant for all the experts. In addition, we have also provided the area-under-curve and
area-under-precision-recall curve are computed based on binary labels (similar vs. not
related) for each run.
Figure 4: Inter-rater comparison across eight experts for seizure similarity: (A) four-
level classification percentage agreement, (B) four-level classification beyond-chance Gwet’s
kappa. The percentage agreement and kappa were moderate implying there exists reasonable
agreement in seizure similarity across experts. (C) Calibration curves for the eight experts for
binary similarity scores with group probability in five bins. For each individual expert, we
applied polynomial fitting of degree two to estimate the calibration curve. The individual
expert values are represented in red. Most of the individual calibration curves align with the
Reference
line (black). For each group probability bin, the red markers indicate an expert
individual probability which may overlap with other experts.
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
19
Figure 5: Univariate analysis of features for seizure similarity with the mean expert
similarity scores. Here we illustrate the mean expert scores for each pair of seizures (y-axis)
vs. the feature values (x-axis). The expert scores ranged from 0 and 1, with a higher value
indicating better similarity between the seizures. Each red circle represents the similarity
score of a pair of seizures. In addition, we also illustrate the correlation line that has been
fitted through these points. Rho value ranges between [0, 1] with a high rho value indicating
better correlation. The rho values were moderate to high for the six features. We used
subjective correlation values for evaluating the similarity across seizure onset patterns based
on the opinion of experts (Supplementary Figure 1). The seizure onset region had the highest
rho value with the mean expert scores.
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
20
Figure 6: Seizure similarity feature ranking determined by univariate, multivariate, and
survey-based analysis (A) Spearman rho values derived for each feature across the eight
expert scores. Overall, the onset region had higher mean rho values indicating higher
correlation with the expert scores. (B) Feature importance derived based on leave-one-
expert-out (LOEO) results for binary similarity classification. The onset region was identified
as the most important feature to determine seizure similarity. (C) Feature importance derived
based on expert opinion survey. The experts also suggested the onset region as the most
important feature in determining seizure similarity. (D) Detailed results of feature importance
of the expert opinion survey. The onset region was ranked the best feature (seven out of eight
experts).
Supplementary material
Supplementary Table 1. Clinical patient details
Supplementary Figure 1: Graphical User Interface
Supplementary S1: Implementation of similarity features across seizure pairs
Supplementary Figure 2: Subjective correlation matrix for seizure onset patterns
Supplementary Figure 3: Feature correlation matrix
Supplementary S2: Survey document
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
21
All rights reserved. No reuse allowed without permission.
(which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity.
The copyright holder for this preprintthis version posted January 22, 2024. ; https://doi.org/10.1101/2024.01.21.24301546doi: medRxiv preprint
Text is read by the "Ask this paper" AI Q&A widget below.
Extraction quality varies by source — PMC NXML preserves structure
cleanly, OA-HTML may include some navigation residue, and OA-PDF can
have broken hyphenation. The publisher copy
(via DOI)
is the canonical version.