Multi-curie Production of Gallium-68 on a Biomedical Cyclotron and Automated Radiolabelling of PSMA-11 and DOTATATE

preprint OA: closed CC-BY-4.0
📄 Open PDF View at publisher

Abstract

Abstract Background: With increasing clinical demand for gallium-68, commercial germanium-68/gallium-68 ([68Ge]Ge/[68Ga]Ga) generators are incapable of supplying sufficient amounts of the short-lived daughter isotope. In this study, we demonstrate a high-yield, automated method for producing multi-Curie levels of [68Ga]GaCl3 from solid zinc-68 targets and subsequent labelling to produce clinical-grade [68Ga]Ga-PSMA-11 and [68Ga]Ga-DOTATATE.Results: Enriched zinc-68 targets were irradiated at up to 80 µA with 13 MeV protons for 120 min; repeatedly producing up to 194 GBq (5.24 Ci) of purified gallium-68 in the form of [68Ga]GaCl3 at the end of purification (EOP) from an expected >370 GBq (>10 Ci) at end of bombardment. A fully automated dissolution/separation process was completed in 35 min. Isolated product was analysed according to the draft Ph. Eur. monograph for accelerator produced [68Ga]GaCl3 and found to comply with all specifications. In every instance, the radiochemical purity exceeded 99.9% and importantly, the radionuclidic purity was sufficient to allow for a shelf-life of up to 7 h based on this metric alone. Fully automated production of up to 72.2 GBq [68Ga]Ga-PSMA-11 was performed, providing a product with high radiochemical purity (>98.2%) and very high apparent molar activities of up to 722 MBq/nmol. Further, manual radiolabelling of up to 3.2 GBq DOTATATE was performed in high yields (>95%) and with apparent molar activities (9-25 MBq/nmol) sufficient for clinical use.Conclusions: We have developed a high-yielding, automated method for the production of very high amounts of [68Ga]GaCl3, sufficient for supply proximal radiopharmacies. The reported method led to record-high purified gallium-68 activities (194 GBq at end of purification) and subsequent labelling of PSMA-11 and DOTATATE. The process was highly automated from irradiation through to formulation of the product, and as such comprised a high level of radiation protection. The quality control results obtained for both [68Ga]GaCl3 for radiolabelling and [68Ga]Ga-PSMA-11 are promising for clinical use.

My notes (saved in your browser only)

Citation neighborhood (no data yet)

We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.

Source provenance

europepmc
last seen: 2026-05-19T01:45:01.086888+00:00
unpaywall
last seen: 2026-05-22T02:00:06.705733+00:00
License: CC-BY-4.0